Loading...
21-102 Encroachment Agreement, GTE Mobilnet of California Limited Partnership, dba Verizon Wireless, R.O.W, near 21055 Lauretta DriveThis Encroachment Agreement (“Encroachment Agreement”), made as of the last date signed below (“Effective Date”) between the City of Cupertino, a political subdivision of the State of California, hereinafter designated “Licensor” and GTE Mobilnet of California Limited Partnership, d/b/a Verizon Wireless, with its principal offices at c/o Verizon Wireless, 180 Washington Valley Road, Bedminster, New Jersey 07921, hereinafter designated “Licensee”: 1.Encroachment Agreement. This is an Encroachment Agreement as referenced in that certain Small Cell License Agreement between Licensor and Licensee dated May 16, 2017 ("Agreement"). This Encroachment Agreement shall serve as an encroachment license. All of the terms and conditions of the Agreement are incorporated hereby by reference and made a part hereof without the necessity of repeating or attaching the Agreement. In the event of a contradiction, modification or inconsistency between the terms of the Agreement and this Encroachment Agreement, the terms of the Encroachment Agreement shall govern. Capitalized terms used in this Encroachment Agreement shall have the same meaning described for them in the Agreement unless otherwise indicated herein. 2.Project Description and Locations. Licensee shall have the right to use the ROW for a Small Cell at the designated areas in the ROW as further described in Attachment 1 attached hereto (the “Licensed Area”). 3. Equipment. The Small Cell to be installed at the Licensed Area is described in Attachment 1 attached hereto. 4.Term. The term of this Encroachment Agreement shall be as set forth in Section 2 of the Agreement. 5.Fees. The initial annual Rent for the term of this Encroachment Agreement shall be Three Hundred Dollars ($300) and paid in accordance with Paragraph 5.1 of the Agreement, as amended by Section 4, to that certain Settlement Agreement and Mutual Release entered into between Licensor and Licensee dated October 4, 2017, and as adjusted by Paragraph 5.2 of the Agreement. 6.Commencement Date. The first day of the month following the date Licensee has Commenced Installation of its Equipment at the Licensed Area. 7. Approvals/Fiber. It is understood and agreed that Licensee's ability to use the Licensed Area is contingent upon its obtaining all of the certificates, permits and other approvals (collectively the "Governmental Approvals") that may be required by any Federal, State or Local authorities, as well as a satisfactory fiber and electrical connection which will permit Licensee use of the Licensed Area as set forth above. In the event that (i) any of such applications for such Governmental Approvals should be finally rejected; (ii) any Governmental Approval issued to Licensee is canceled, expires, lapses, or is otherwise withdrawn or terminated by governmental authority; (iii) Licensee determines that such Governmental Approvals may not be obtained in a CA_SJ_CUPERTINO_318 (NEAR) 21055 LAURETTA DR ENCROACHMENT AGREEMENT 545475DocuSign Envelope ID: 0191F786-7273-498E-9298-A882149BC086DocuSign Envelope ID: AD4DAD06-1539-4E9D-9345-A186446DEE71 timely manner; (iv) Licensee determines that it will be unable to obtain in a satisfactory manner, or maintain any fiber or power connection; or (v) Licensee determines that the Licensed Area is no longer technically compatible for its use, Licensee shall have the right to terminate this Encroachment Agreement. Notice of Licensee's exercise of its right to terminate shall be given to Licensee in writing by certified mail, return receipt requested, and shall be effective upon the mailing of such notice by Licensee, or upon such later date as designated by Licensee. All rentals paid to said termination date shall be retained by Licensor. Upon such termination, this Encroachment Agreement shall be of no further force or effect except to the extent of the representations, warranties and indemnities made by each party to the other hereunder. Otherwise, Licensee shall have no further obligations for the payment of Rent to Licensor. 8.Miscellaneous. N/A [Signature page follows] DocuSign Envelope ID: 0191F786-7273-498E-9298-A882149BC086DocuSign Envelope ID: AD4DAD06-1539-4E9D-9345-A186446DEE71 EXECUTED to be effective as of the last date shown below. LICENSOR: City of Cupertino, a political subdivision of the State of California By: ___________________________ Name: _________________________ Title: __________________________ Date: ___________________________ ATTEST: Date: ___________________________ APPROVED AS TO FORM CITY ATTORNEY’S OFFICE BY: __________________________ Print Name: _____________________ Date: __________________________ City Attorney LICENSEE: GTE MOBILNET OF CALIFORNIA LIMITED PARTNERSHIP, D/B/A VERIZON WIRELESS by Cellco Partnership, its General Partner By: Date: ______________________________ Name: Alba Barber Title: Senior Real Estate Manager Exhibits: Attachment 1 , Clerk DocuSign Envelope ID: 0191F786-7273-498E-9298-A882149BC086DocuSign Envelope ID: AD4DAD06-1539-4E9D-9345-A186446DEE71 May 24, 2021 Heather Minner May 27, 2021 City Engineer Jun 9, 2021 Chad Mosley Jun 9, 2021 Attachment 1 Licensed Area See attached. DocuSign Envelope ID: 0191F786-7273-498E-9298-A882149BC086DocuSign Envelope ID: AD4DAD06-1539-4E9D-9345-A186446DEE71 T-1 TITLE SHEET DRAWN BY: CHECKED BY:BPM APE IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT 0 08/12/20 100% CD REV DATE DESCRIPTION MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 APPROVED BY:LJB CA_SJ_CUPERTINO_318 VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 (NEAR) 21055 LAURETTA DR CUPERTINO, CA 95014 1 12/14/20 100% CD PLAN CHECK SITE INFORMATION SITE ADDRESS: OWNER: APPLICANT: LATITUDE: LONGITUDE: COUNTY: ASSESSORS PARCEL NUMBER: ZONING: ELEVATION: CITY OF CUPERTINO 10300 TORRE AVE CUPERTINO, CA 95014 VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 37° 19' 40.19" N NAD83 122° 2' 29.52" W NAD83 SANTA CLARA PUBLIC RIGHT OF WAY NEAR 326-55-006 CITY OF CUPERTINO 260.27' AMSL VICINITY MAPPOLE PHOTO N DRAWING INDEX T-1 SHEET NO. TITLE SHEET T-2 GENERAL NOTES A-1 SITE PLAN & ENLARGED SITE PLAN A-2 A-4 ELEVATIONS CIRCUIT DIAGRAM D-1 DETAILS CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES. ·2019 CALIFORNIA CODE ·2019 CALIFORNIA BUILDING CODE (CBC), BASED ON THE 2018 IBC ·2019 CALIFORNIA RESIDENTIAL CODE (CRC), BASED ON THE 2018 IRC ·2019 CALIFORNIA ELECTRICAL CODE (CEC), BASED ON THE 2017 NEC ·2019 CALIFORNIA MECHANICAL CODE (CMC), BASED ON THE 2018 UMC ·2019 CALIFORNIA PLUMBING CODE (CPC), BASED ON THE 2018 UPC ·2019 CALIFORNIA GREEN BUILDINGS STANDARDS CODE (CALGREEN) ·2019 CALIFORNIA FIRE CODES WITH ALL LOCAL AMENDMENTS ·ANY LOCAL BUILDING CODE AMENDMENTS TO THE ABOVE ·CITY / COUNTY ORDINANCES SHEET TITLE E-1 ELECTRICAL GENERAL NOTES E-2 ONE-LINE DIAGRAM & GROUNDING SCHEMATIC E-3 ELECTRICAL DETAILS ACCESSIBILITY REQUIREMENTS FOR PERSONS WITH DISABILITIES: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. ACCESSIBILITY IS NOT REQUIRED IN ACCORDANCE WITH CALIFORNIA ADMINISTRATIVE STATE CODE PART 2, TITLE 24, CHAPTER 11B, SECTION 1103B. 21055 LAURETTA DRIVE SURVEY PROJECT TEAM PROJECT DESCRIPTION D-2 DETAILS THE UTILITIES SHOWN HEREIN ARE FOR THE CONTRACTORS CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THE ENGINEER/SURVEYOR ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL THE UTILITIES WITHIN THE LIMITS OF THE WORK. ALL DAMAGE MADE TO THE (E) UTILITIES BY THE CONTRACTOR SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. CALL 811 BEFORE YOU DIG IT'S THE LAW MODUS PROJECT MANAGER: MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 PHONE: (415) 989.1102 EMAIL: VERIZONPOLYGONTEAM@MODUS-CORP.COM CONSTRUCTION/IMPLEMENTATION MANAGER: MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 PHONE: (415) 989.1102 EMAIL: VERIZONPOLYGONTEAM@MODUS-CORP.COM A&E PROJECT MANAGER: MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 PHONE: (415) 989.1102 EMAIL: VERIZONPOLYGONTEAM@MODUS-CORP.COM APPLICANT: VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 CONTACT: CHRIS MOLLER PHONE: (925) 339.2778 EMAIL: CHRIS.MOLLER@VERIZONWIRELESS.COM LAND USE PLANNER: MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 PHONE: (415) 989.1102 EMAIL: VERIZONPOLYGONTEAM@MODUS-CORP.COM SITE ACQUISITION: MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 PHONE: (415) 989.1102 EMAIL: VERIZONPOLYGONTEAM@MODUS-CORP.COM SITE C-1 A-3 ELEVATIONS VERIZON WIRELESS PROPOSES TO INSTALL A NEW WIRELESS COMMUNICATION SITE ON A LIGHT POLE IN THE PUBLIC RIGHT-OF-WAY. SCOPE: ·INSTALL (2) 5G ANTENNA/RADIOS INSIDE NEW FRP CONCEALMENT SHROUD ON TOP OF POLE ·INSTALL (1) NEW DISCONNECT / SMART METER ON SIDE OF POLE ·INSTALL NEW POLE AND FOUNDATION TO REPLACE EXISTING D-3 POLE SPECS (NEAR) 21055 LAURETTA DR CUPERTINO, CA 95014 (NEAR) 21055 LAURETTA DR CUPERTINO, CA 95014 CA_SJ_CUPERTINO_318 SITE ID: SITE TYPE: POLE #: CX PROJECT ID: COUNTY: PSLC: CA_SJ_CUPERTINO_318 LIGHT POLE 20281 20191962655 SANTA CLARA 545475 D-4 CITY STANDARD DETAILS N. Stelling Rd DocuSign Envelope ID: 0191F786-7273-498E-9298-A882149BC086DocuSign Envelope ID: AD4DAD06-1539-4E9D-9345-A186446DEE71 DRAWN BY: CHECKED BY:BPM APE IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT 0 08/12/20 100% CD REV DATE DESCRIPTION MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 APPROVED BY:LJB CA_SJ_CUPERTINO_318 VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 (NEAR) 21055 LAURETTA DR CUPERTINO, CA 95014 1 12/14/20 100% CD PLAN CHECK T-2 GENERAL NOTES GENERAL CONSTRUCTION NOTES APPLICABLE CODES, REGULATIONS AND STANDARDS: GENERAL TRENCHING NOTES 1. MAINTAIN 24" MINIMUM COVER FOR ALL ELECTRICAL CONDUITS, U.O.N. 2. MAINTAIN 30" MINIMUM COVER FOR ALL TELECOMMUNICATIONS CONDUITS. 3. MINIMUM 1" SAND SHADING BELOW CONDUITS, AND 6" COVERING ON TOP OF CONDUITS REQUIRED. 4. REFER TO SHEET E-1 FOR ADDITIONAL REQUIREMENTS GENERAL GROUNDING NOTES 1. GROUNDING SHALL BE TESTED AT 5 OHMS OR LESS. 2. WOOD MOLDING, STAPLED EVERY 3'-0" AND AT EACH END. GENERAL CONDUIT NOTES 1. ALL CONDUITS WILL BE MANDRELED AND EQUIPPED WITH 3/8" PULL ROPE. 2. SCHEDULE 40 CONDUIT FOR UNDERGROUND USE. 3. SCHEDULE 80 CONDUIT FOR RISER USE AND ELSEWHERE AS NOTES. TRANSITION FROM SCHEDULE 40 PVC OR RIGID STEEL CONDUIT TO SCHEDULE 80 USING APPROVED FITTINGS DESIGNED TO PROVIDE A SMOOTH INTERIOR WALL TRANSITION TO THE REDUCED INTERIOR DIAMETER OF SCHEDULE 80. ADJUST CONDUIT SIZE IF NECESSARY TO MAINTAIN THE INTERIOR AREA REQUIRED FOR THE WIRING SPECIFIED. 4. GALVANIZED STEEL CONDUIT FOR ANY CONDUIT UNDER 3", STUB UP 10" THEN CONVERT TO SCHEDULE 80. 5. CONTRACTOR TO STUB UP POLE 10" w/ 3" POWER CONDUIT. POWER COMPANY TO CONVERT FROM 3" STUB SCHEDULE 80 TO 2" SCHEDULE 80 FROM TOP OF STUB UP. 6. ZRC COLD GALVANIZING COMPOUND OR EQUIVALENT IS REQUIRED ON EXPOSED THREADS IN RIGID STEEL CONDUIT AND THE CUT ENDS OF SUPPORT STRUTS, ETC. TO PREVENT RUSTING. TYPICAL R.O.W. POLE CONSTRUCTION NOTES 1. CABLE NOT TO IMPEDE 15" CLEAR SPACE OFF POLE FACE. 2. ALL CLIMB STEPS NEXT TO CONDUIT SHALL HAVE EXTENDED STEPS. 3. NO BOLT THREADS TO PROTRUDE MORE THAN 1-1/2" 4. ALL HOLES IN POLE LEFT FROM REARRANGEMENT OF CLIMB STEPS TO BE FILLED. 5. 90° SHORT SWEEPS UNDER ANTENNA ARM, ALL CABLES MUST TRANSITION ON THE INSIDE OR BOTTOM OF THE ARM (NO CABLE ON TOP OF ARM). 6. USE 90° CONNECTOR AT CABLE CONNECTION FOR OMNI DOWN ANTENNAS. 7. USE CABLE CLAMPS TO SECURE CABLE TO ARMS, PLACE 2" CABLE I.D. TAGS ON BOTH SIDES OF ARMS. 8. USE 1/2" DIA. CABLE ON ANTENNAS UNLESS OTHERWISE SPECIFIED. 9. PLACE GPS ON ARM OF SOUTHERN SKY EXPOSURE AT MINIMUM 6" FROM TRANSMIT ANTENNA WHICH IS 24" AWAY FROM CENTER OF POLE. 10. FILL VOID AROUND CABLES AT CONDUIT OPENING WITH FOAM SEALANT TO PREVENT WATER INTRUSION. W ALTERNATE COLUMN L CONTRACTOR REQUIREMENTS DO NOT SCALE OFF DRAWINGS CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK GENERAL NOTES 1. PLANS ARE INTENDED TO BE DIAGRAMMATIC ONLY, UNLESS NOTED OTHERWISE. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 2. THE CONTRACTOR SHALL OBTAIN, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. 3. CONTRACTOR SHALL CONTACT USA (UNDERGROUND SERVICE ALERT) AT (800) 227-2600, FOR UTILITY LOCATIONS, 2 WORKING DAYS BEFORE PROCEEDING WITH ANY EXCAVATION, SITE WORK OR CONSTRUCTION. 4. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OTHERWISE, OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 5. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CBC'S REQUIREMENTS REGARDING EARTHQUAKE RESISTANCE, FOR, BUT NOT LIMITED TO, PIPING, LIGHT FIXTURES, CEILING GRID, INTERIOR PARTITIONS, AND MECHANICAL EQUIPMENT. ALL WORK MUST COMPLY WITH LOCAL EARTHQUAKE CODES AND REGULATIONS. 6. REPRESENTATIONS OF TRUE NORTH, OTHER THAN THOSE FOUND ON THE PLOT OF SURVEY DRAWINGS, SHALL NOT BE USED TO IDENTIFY OR ESTABLISH BEARING OF TRUE NORTH AT THE SITE. THE CONTRACTOR SHALL RELY SOLELY ON THE PLOT OF SURVEY DRAWING AND ANY SURVEYOR'S MARKINGS AT THE SITE FOR THE ESTABLISHMENT OF TRUE NORTH, AND SHALL NOTIFY THE ARCHITECT / ENGINEER PRIOR TO PROCEEDING WITH THE WORK IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND THE TRUE NORTH ORIENTATION AS DEPICTED ON THE CIVIL SURVEY. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE TO NOTIFY THE ARCHITECT / ENGINEER. 7. THE BUILDING DEPARTMENT ISSUING THE PERMITS SHALL BE NOTIFIED AT LEAST TWO WORKING DAYS PRIOR TO THE COMMENCEMENT OF WORK, OR AS OTHERWISE STIPULATED BY THE CODE ENFORCEMENT OFFICIAL HAVING JURISDICTION. 8. DO NOT EXCAVATE OR DISTURB BEYOND THE PROPERTY LINES OR LEASE AREA LINES, UNLESS OTHERWISE NOTED. 9. ALL EXISTING UTILITIES, FACILITIES, CONDITIONS, AND THEIR DIMENSIONS SHOWN ON THE PLAN HAVE BEEN PLOTTED FROM AVAILABLE RECORDS. THE ARCHITECT / ENGINEER AND THE OWNER ASSUME NO RESPONSIBILITY WHATSOEVER AS TO THE SUFFICIENCY OR THE ACCURACY OF THE INFORMATION SHOWN ON THE PLANS, OR THE MANNER OF THEIR REMOVAL OR ADJUSTMENT. CONTRACTORS SHALL BE RESPONSIBLE FOR DETERMINING EXACT LOCATION OF ALL EXISTING UTILITIES AND FACILITIES PRIOR TO START OF CONSTRUCTION. CONTRACTORS SHALL ALSO OBTAIN FROM EACH UTILITY COMPANY DETAILED INFORMATION RELATIVE TO WORKING SCHEDULES AND METHODS OF REMOVING OR ADJUSTING EXISTING UTILITIES. 10. CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES, BOTH HORIZONTAL AND VERTICALLY, PRIOR TO THE START OF CONSTRUCTION. ANY DISCREPANCIES OR DOUBTS AS TO THE INTERPRETATION OF PLANS SHOULD BE IMMEDIATELY REPORTED TO THE ARCHITECT / ENGINEER FOR RESOLUTION AND INSTRUCTION, AND NO FURTHER WORK SHALL BE PERFORMED UNTIL THE DISCREPANCY IS CHECKED AND CORRECTED BY THE ARCHITECT / ENGINEER. FAILURE TO SECURE SUCH INSTRUCTION MEANS CONTRACTOR WILL HAVE WORKED AT HIS/HER OWN RISK AND EXPENSE. 11. ALL NEW AND EXISTING UTILITY STRUCTURES ON SITE AND IN AREAS TO BE DISTURBED BY CONSTRUCTION SHALL BE ADJUSTED TO FINISH ELEVATIONS PRIOR TO FINAL INSPECTION OF WORK. 12. ANY EXISTING COMPONENTS DISTURBED DURING CONSTRUCTION SHALL BE RETURNED TO IT'S ORIGINAL CONDITION PRIOR TO COMPLETION OF WORK. SIZE, LOCATION AND TYPE OF ANY UNDERGROUND UTILITIES OR IMPROVEMENTS SHALL BE ACCURATELY NOTED AND PLACED ON "AS-BUILT" DRAWINGS BY GENERAL CONTRACTOR, AND ISSUED TO THE ARCHITECT / ENGINEER AT COMPLETION OF PROJECT. 13. ALL TEMPORARY EXCAVATIONS FOR THE INSTALLATION OF FOUNDATIONS, UTILITIES, ETC., SHALL BE PROPERLY LAID BACK OR BRACED IN ACCORDANCE WITH CORRECT OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) REQUIREMENTS. A.B. ABV. ADD'L ACCA A.F.F. A.F.G. AGL ALUM ALT. AMSL ANT. APPRX. ARCH. AWG. BLDG. BLK. BLKG BM. B.N. BN CAB. BTCW. B.O. B.O.F. CANT. C.I.P. CLG. CLR. COL. CONC. CONN. CONST. CONT. d DBL. DEPT. D.F. DIA. DIAG. DIM. DWG. DWL. EA. EL. ELEC. ELEV. EMT. E.N. ENG. EQ. EXP. EXST.(E) EXT. FAB. GPS GLB. (GLU-LAM) G.F.I. GI. GA. G. FTG. FT.(') F.S. F.O.W. F.O.S. F.O.M. F.O.C. FDN. FLR. FIN. F.G. F.F. ANCHOR BOLT ABOVE ANTENNA CABLE COVER ASSEMBLY ADDITIONAL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ABOVE GROUND LEVEL ALUMINUM ABOVE SEA LEVEL ANTENNA APPROXIMATE(LY) ARCHITECT(URAL) AMERICAN WIRE GAUGE BUILDING BLOCK BLOCKING BEAM BOUNDARY NAILING BACK-UP CABINET CABINET BARE TINNED COPPER WIRE BOTTOM BOTTOM OF FOOTING CANTILEVER(ED) CAST IN PLACE CEILING CLEAR CONCRETE CONNECTION(OR) CONSTRUCTION CONTINUOUS PENNY (NAILS) DOUBLE DEPARTMENT DOUGLAS FIR DIAMETER DIAGONAL DIMENSION DRAWING(S) DOWEL(S) EACH ELEVATION ELECTRICAL ELEVATOR ELECTRICAL METALLIC TUBING EDGE NAIL ENGINEER EQUAL EXPANSION EXISTING EXTERIOR FABRICATION(OR) FINISH FLOOR FINISH GRADE FINISH(ED) FLOOR FOUNDATION FACE OF CONCRETE FACE OF MASONRY FACE OF STUD FACE OF WALL FINISH SURFACE FOOT(FEET) FOOTING GROWTH(CABINET) GAUGE GALVANIZE(D) GROUND FAULT CIRCUIT INTERRUPTER GLUE LAMINATED BEAM GLOBAL POSITIONING SYSTEM GRND. GROUND HEADERHDR. HGR.HANGER HEIGHTHT. ICGB.ISOLATED COPPER GROUND BUS INCH(ES)IN.(") INT.INTERIOR LB.(#) L.B. L.F. LAG BOLTS POUND(s) LINEAR FEET(FOOT) L. MAS. MASONRY LONGITUDINAL MAXIMUMMAX. M.B. MECH. MFR. MIN. MISC. MTL.METAL MISCELLANEOUS MINIMUM MANUFACTURER MECHANICAL MACHINE BOLT LP C WT. W.P. WD. W/ V.I.F. U.L. U.N.O. U.G. TYP. T.O.W. T.O.S. T.O.P. T.O.F. T.O.C. T.O.A. T.N. THK. TEMP. STRUC. STL. STD. S.S. SQ. SPEC. SIM. SHT. SCH. RGS. REQ'D. REINF. REF. RAD.(R) QTY. PWR. P.T. P.S.I. P.S.F. PRC. PPC. PLY. PCS P/C OPNG. O.C. N.T.S. NO.(#) (N)NEW NUMBER NOT TO SCALE OPENING PRE CAST CONCRETE PERSONAL COMMUNICATION SERVICES PLYWOOD POWER PROTECTION CABINET PRIMARY FLEXING CABINET POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PRESSURE TREATED POWER (CABINET) QUANTITY RADIUS REFERENCE REINFORCING REQUIRED RIGID GALVANIZED STEEL SCHEDULE SHEET SIMILAR SPECIFICATION(S) SQUARE STAINLESS STEEL STANDARD STEEL STRUCTURAL TEMPORARY THICKNESS TOE NAIL TOP OF ANTENNA TOP OF CURB TOP OF FOUNDATION TOP OF STEEL TOP OF WALL TYPICAL UNDER GROUND UNDERWRITES LABORATORY UNLESS NOTED OTHERWISE VERIFY IN FIELD WIDE(WIDTH) WITH WOOD WEATHERPROOF WEIGHT CENTERLINE PLATE ON CENTER TOP OF PLATE(PARAPET) 1. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CONTRACTOR. 2. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS MUST BE VERIFIED. CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 3. THE EXISTING CELL SITE IS IN FULL COMMERCIAL OPERATION. ANY CONSTRUCTION WORK BY CONTRACTOR SHALL NOT DISRUPT THE EXISTING NORMAL OPERATION. ANY WORK ON EXISTING EQUIPMENT MUST BE COORDINATED WITH CONTRACTOR. ALSO, WORK SHOULD BE SCHEDULED FOR AN APPROPRIATE MAINTENANCE WINDOW USUALLY IN LOW TRAFFIC PERIODS AFTER MIDNIGHT. 4. SINCE THE CELL SITE IS ACTIVE, ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN WORKING AROUND HIGH LEVELS OF ELECTROMAGNETIC RADIATION. EQUIPMENT SHOULD BE SHUTDOWN PRIOR TO PERFORMING ANY WORK THAT COULD EXPOSE THE WORKERS TO DANGER. PERSONAL RF EXPOSURE MONITORS ARE ADVISED TO BE WORN TO ALERT OF ANY DANGEROUS EXPOSURE LEVELS. 5. CONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWING. CONTRACTOR SHALL UTILIZE EXISTING TRAYS AND/OR SHALL ADD (N) TRAYS AS NECESSARY. CONTRACTOR SHALL CONFIRM THE ACTUAL ROUTING WITH THE CONTRACTOR. 6. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. ABBREVIATIONS 1. CONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. 2. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE TIME OF PERMITTING AWARD SHALL GOVERN THE DESIGN. 3. CONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING STANDARDS: 3.1. - AMERICAN CONCRETE INSTITUTE (ACI) 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 3.2. - AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, ASD, NINTH EDITION 3.3. - TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 222-F, STRUCTURAL STANDARD FOR STRUCTURAL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES 3.4. - INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING EARTH RESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND SYSTEM IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OF ELECTRICAL EQUIPMENT. 3.5. -IEEE C62.41, RECOMMENDED PRACTICES ON SURGE VOLTAGES IN LOW VOLTAGE AC POWER CIRCUITS (FOR LOCATION CATEGORY "C3" AND "HIGH SYSTEM EXPOSURE") 4. TIA 607 COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS 4.1. TELCORDIA GR-63 NETWORK EQUIPMENT-BUILDING SYSTEM (NEBS): PHYSICAL PROTECTION 4.2. TELCORDIA GR-347 CENTRAL OFFICE POWER WIRING 4.3. TELCORDIA GR-1275 GENERAL INSTALLATION REQUIREMENTS 4.4. TELCORDIA GR-1503 COAXIAL CABLE CONNECTIONS 5. ANY AND ALL OTHER LOCAL & STATE LAWS AND REGULATIONS 6. FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING MATERIAL, METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN. R.O.W. RIGHT OF WAY X-X X-X X X-X x X X X O/H A E T X E/T OHT/OHP OHT OHP LEGEND SPOT ELEVATION REVISION GRID REFERENCE DETAIL REFERENCE ELEVATION REFERENCE SECTION REFERENCE (E) BRICK (E) MASONRY CONCRETE EARTH GRAVEL PLYWOOD SAND STEEL CENTERLINE PROPERTY/LEASE LINE MATCH LINE WORK POINT GROUND CONDUCTOR TELEPHONE CONDUIT ELECTRICAL CONDUIT ELECTRICAL & TELCO CONDUITS COAXIAL CABLE OVERHEAD SERVICE CONDUCTORS CHAIN LINK FENCING WOOD FENCING OVERHEAD TELEPHONE/ OVERHEAD POWER OVERHEAD TELEPHONE OVERHEAD POWER LINE GROUT OR PLASTER DocuSign Envelope ID: 0191F786-7273-498E-9298-A882149BC086DocuSign Envelope ID: AD4DAD06-1539-4E9D-9345-A186446DEE71 LIGHT POLE PROPOSED LOCATION OF FACILITIES: LATITUDE: 37°19'40.19"N LONGITUDE: 122°2'29.52"W ELEVATION: 260.27' 7'-5"± BACK OF POLE TO RIGHT-OF-WAY 21008 HAZELBROOK DR CUPERTINO, CA 95014 21014 HAZELBROOK DR CUPERTINO, CA 95014 21065 LAURETTA DR CUPERTINO, CA 95014 21055 LAURETTA DR CUPERTINO, CA 95014 10322 N STELLING RD CUPERTINO, CA 95014 10336 N STELLING RD CUPERTINO, CA 95014 10352 N STELLING RD CUPERTINO, CA 95014 FA C E O F T H E C U R B LA N D S C A P E (E ) C O N C R E T E S I D E W A L K FA C E O F T H E C U R B LA N D S C A P E (E ) C O N C R E T E S I D E W A L K FA C E O F T H E C U R B LA N D S C A P E (E ) C O N C R E T E S I D E W A L K FA C E O F T H E C U R B LA N D S C A P E (E ) C O N C R E T E S I D E W A L K D/ W D/ W N S T E L L I N G R D CT R - L I N E N S T E L L I N G R D CT R - L I N E WESTERLY RIGHT-OF-WAY N STELLING RD EASTERLY RIGHT-OF-WAY N STELLING RD 2' 3" AT 96.45° 6' AT 98 .53° 2' 9" AT 250.27° D/ W FE N C E FE N C E FE N C E FE N C E APN: 32655006 (E) GRADE 260.27' Center pole Latitude 37.327831 N Longitude -122.041534 W NAD83 & WGS84 Pole height: 30' NAVD88 VERTICAL DATUM THE NORTH AMERICAN VERTICAL DATUM OF 1988 ("NAVD88") (E) TOP OF SIGN, 1' 8'-8" AGL (E) BOTTOM OF SIGN 7'-2" AGL (E) LIGHT ARM, 5'7"; HEAD, 2'3.. 29'-7" AGL (E) TOP OF POLE 30' AGL (E) TOP OF LIGHT 31'-7" AGL 4746 Clayton Rd,Concord, CA, 94521. (925) 408-2159 e splanneng@gmail.com 8 * ( www.planneng.com SHEET: C1 Pole ID: 20281 SCALE: 1" = 8' CA_SJ_CUPERTINO_318 21055 LAURETTA DR, CUPERTINO, CA 95014 N REF PLAT # BK. 326 - PG. 55 DocuSign Envelope ID: 0191F786-7273-498E-9298-A882149BC086DocuSign Envelope ID: AD4DAD06-1539-4E9D-9345-A186446DEE71 O / H O / H S/ L S/ L S/ L FI B E R S/ L S/ L FIB E R FIB E R O / H O / H O / H O / H O / H O / H O / H O / H O / H O / H O / H O / H O / H O / H O / H O / H O / H O / H O / H S/ L S/ L DRAWN BY: CHECKED BY:BPM APE IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT 0 08/12/20 100% CD REV DATE DESCRIPTION MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 APPROVED BY:LJB CA_SJ_CUPERTINO_318 VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 (NEAR) 21055 LAURETTA DR CUPERTINO, CA 95014 1 12/14/20 100% CD PLAN CHECK A-1 SITE PLAN 1ENLARGED SITE PLAN N SITE PLAN3 N 3 A-1 ENLARGED SITE PLAN 1/16"=1'-0" SCALE 1/2"=1'-0" SCALE (E) LIGHT POLE & FOUNDATION TO BE REMOVED. (N) LIGHT POLE & FOUNDATION TO BE INSTALLED IN PLACE (N) LOCATION OF VERIZON WIRELESS ANTENNA IN FRP SHROUD MOUNTED ON LIGHT POLE (N) LOCATION OF VERIZON WIRELESS ANTENNA AND EQUIPMENT ELECTRICAL LINE STREET LIGHT LINE E S/L FIBER LINE(S)FIBER LEGEND (N) STEEL MAST ARM (E) LUMINAIRE REMOVE & REPLACE CONCRETE, APPROX. 25 SQ. FT. AT APPROXIMATE LIMITS TO MATCH EXISTING ADJACENT ELEVATIONS, REPLACE WHOLE FLAGS, NOT PARTIAL SE C T O R AZ I M U T H 1 8 0 5G B SE C T O R AZ I M U T H 0 5G A 4'-0"± MIN. ADA CLEARANCE BACK OF POLE TO EDGE OF SIDEWALK N S T E L L I N G R D 10336 N STELLING AVE CUPERTINO, CA 95014 (E ) FA C E O F T H E C U R B PR O P E R T Y L I N E (E ) LA N D S C A P E (E ) DR I V E W A Y (E ) F A C E O F T H E C U R B PR O P E R T Y L I N E (E ) LA N D S C A P E (E ) FA C E O F T H E C U R B (E ) LA N D S C A P E PR O P E R T Y L I N E (E ) CO N C R E T E S I D E W A L K (E ) CO N C R E T E S I D E W A L K (E ) CO N C R E T E S I D E W A L K (E ) FA C E O F T H E C U R B (E ) LA N D S C A P E PR O P E R T Y L I N E (E ) CO N C R E T E S I D E W A L K (E ) D/ W A.P.N.: 326-55-006 21055 LAURETTA DR CUPERTINO, CA 95014 21065 LAURETTA DR CUPERTINO, CA 95014 10352 N STELLING AVE CUPERTINO, CA 9501421008 HAZELBROOK DR CUPERTINO, CA 95014 (E ) D/ W N1 N2 NC 2 NC 1 EC 1 NC 3 EC 2 7'-5"± BACK OF POLE TO ROW LINE (E) MANHOLE (E ) F A C E O F T H E C U R B (E ) LA N D S C A P E (E ) CO N C R E T E S I D E W A L K PR O P E R T Y L I N E N S T E L L I N G R D (E) INLET 1&2 A-3 1&2 A-2 (E) OVERHEAD UTILITY LINES ATTACHED TO (E) PG&E WOOD UTILITY POLE TO REMAIN, TYP. 2ENLARGED PLAN AT POLE# 20295 1/2"=1'-0" SCALE EC 2 N2 EC 3 EC 3 (E) POLE #20295 TO REMAIN (E) CURB N S T E L L I N G R D 42 5 ' ± F R O M PO L E # 2 0 2 9 5 T O PO L E # 2 0 2 8 1 (E ) FA C E O F T H E C U R B (E ) LA N D S C A P E (E ) CO N C R E T E S I D E W A L K PR O P E R T Y L I N E NOTE: 1. FIBER PULLBOX EXACT LOCATION TO BE VERIFIED IN FIELD 2. UPON COMPLETION OF CONSTRUCTION, RESTORE LANDSCAPE AND IRRIGATION TO LIKE OR BETTER CONDITION, TEST IRRIGATION. 3. UPON COMPLETION OF CONSTRUCTION, NOTIFY THE CITY OF NEW STREETLIGHT INSTALLATION SO THAT NEW BADGE ID NUMBER CAN BE PLACED BY THE CITY ONTO THE NEW STREETLIGHT POLE. NOTE: CARRIER GROUND WIRE TO BE LABELED IN FIELD NOTE: CARRIER GROUND WIRE TO BE LABELED "VERIZON" IN CITY ELECTRICAL BOX 0DVWDUPWREHVDPHDV ( 6/XQOHVV SRVLWLRQLVFKDQJHGWKHQPDVWDUPLVWR EHLQOLQHZLWKDGMDFHQW6/V DocuSign Envelope ID: 0191F786-7273-498E-9298-A882149BC086DocuSign Envelope ID: AD4DAD06-1539-4E9D-9345-A186446DEE71 SHUTDOWN DRAWN BY: CHECKED BY:BPM APE IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT 0 08/12/20 100% CD REV DATE DESCRIPTION MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 APPROVED BY:LJB CA_SJ_CUPERTINO_318 VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 (NEAR) 21055 LAURETTA DR CUPERTINO, CA 95014 1 12/14/20 100% CD PLAN CHECK A-2 EXISTING & PROPOSED ELEVATIONS 12PROPOSED ELEVATIONEXISTING ELEVATION 1/2"=1'-0" SCALE 1/2"=1'-0" SCALE (E) SURFACE 0'-0" AGL (E) SURFACE 0'-0" AGL (E) FOUNDATION (E) LIGHT POLE TO BE REPLACED (E) LUMINAIRE (E) ROAD SIGNS 4 D-2 (N) FOUNDATION (N) 6'-0" MAST ARM NOTES: 1. ALL NEW ANTENNAS, BRACKETS, AND OTHER EQUIPMENT WILL BE PAINTED TO MATCH LIGHT POLE. 2. ALL EXISTING SIGNAGE TO BE RELOCATED SHALL BE FASTENED USING 1/2" STEEL BANDING (N) LIGHT POLE (N) (2) 5G ANTENNAS IN FRP SHROUD 6 D-1 (N) FRP CONCEALMENT SHROUD 1 D-1 T.O. (N) STEEL LIGHT POLE 29'-11" AGL RAD CENTER OF (N) 5G ANTENNA 31'-7" AGL T.O. (N) CONCEALMENT SHROUD 35'-6" AGL 8 D-1 3 E-3 B.O. (N) DISCONNECT 7'-0" AGL T.O. (N) DISCONNECT 8'-9" AGL (N) SMART METER / DISCONNECT w/ SHUTDOWN SIGNAGE 4 D-1 5 D-1 PORT HOLE LOCATION FOR DISCONNECT 1 D-2 (E) ROAD SIGNS (N) LUMINAIRE 1 D-3 7 E-3 T.O. (E) LIGHT SENSOR 31'-8" AGL (N) NOTICE SIGNAGE, TYP. OF (1) FACING STREETSIDE 9 D-1 T.O. (N) NOTICE SIGNAGE 25'-2" AGL 7'-5" BACK OF POLE TO ROW LINE T.O. (E) SIGNS 8'-8" AGL B.O. (E) SIGNS 7'-2" AGL T.O. (E) LIGHT SENSOR 31'-10" AGL (E) LIGHT ARM 29'-7" AGL T.O. (E) STEEL LIGHT POLE 30'-0" AGL T.O. (E) SIGNS 8'-8" AGL B.O. (E) SIGNS 7'-2" AGL 7'-5" BACK OF POLE TO ROW LINE 2' CLEARANCE RADIAL SAFETY ZONE PER GO95 (E) OVERHEAD COMM 22'-7"± AGL (E) OVERHEAD COMM 24'-7"± AGL (E) OVERHEAD COMM 22'-7"± AGL (E) OVERHEAD COMM 24'-7"± AGL 2' CLEARANCE RADIAL SAFETY ZONE PER GO95 DocuSign Envelope ID: 0191F786-7273-498E-9298-A882149BC086DocuSign Envelope ID: AD4DAD06-1539-4E9D-9345-A186446DEE71 O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H DRAWN BY: CHECKED BY:BPM APE IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT 0 08/12/20 100% CD REV DATE DESCRIPTION MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 APPROVED BY:LJB CA_SJ_CUPERTINO_318 VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 (NEAR) 21055 LAURETTA DR CUPERTINO, CA 95014 1 12/14/20 100% CD PLAN CHECK A-3 EXISTING & PROPOSED ELEVATIONS 12PROPOSED ELEVATIONEXISTING ELEVATION 1/2"=1'-0" SCALE 1/2"=1'-0" SCALE (E) FOUNDATION 4 D-2 (N) FOUNDATION (E) LIGHT POLE TO BE REPLACED (E) ROAD SIGNS (N) LIGHT POLE (N) (2) 5G ANTENNAS IN FRP SHROUD 6 D-1 (N) FRP CONCEALMENT SHROUD 1 D-1 T.O. (N) STEEL LIGHT POLE 30'-0" AGL T.O. (N) CONCEALMENT SHROUD 35'-6" AGL 8 D-1 3 E-3 (N) SMART METER / DISCONNECT w/ SHUTDOWN SIGNAGE 4 D-1 5 D-1 PORT HOLE LOCATION FOR DISCONNECT 1 D-2 (E) ROAD SIGNS (N) LUMINAIRE (E) LUMINAIRE 1 D-3 7 E-3 RAD CENTER OF (N) 5G ANTENNA 31'-7" AGL T.O. (E) LIGHT SENSOR 31'-8" AGL T.O. (N) NOTICE SIGNAGE (FACING STREETSIDE) 25'-2" AGL NOTES: 1. ALL NEW ANTENNAS, BRACKETS, AND OTHER EQUIPMENT WILL BE PAINTED TO MATCH LIGHT POLE. 2. ALL EXISTING SIGNAGE TO BE RELOCATED SHALL BE FASTENED USING 1/2" STEEL BANDING (E) SURFACE 0'-0" AGL (E) SURFACE 0'-0" AGL B.O. (N) DISCONNECT 7'-0" AGL T.O. (N) DISCONNECT 8'-9" AGLT.O. (E) SIGNS 8'-8" AGL B.O. (E) SIGNS 7'-2" AGL T.O. (E) LIGHT SENSOR 31'-10" AGL (E) LIGHT ARM 29'-7" AGL T.O. (E) STEEL LIGHT POLE 30'-0" AGL T.O. (E) SIGNS 8'-8" AGL B.O. (E) SIGNS 7'-2" AGL (E) OVERHEAD COMM 22'-7"± AGL (E) OVERHEAD COMM 24'-7"± AGL (E) OVERHEAD COMM 22'-7"± AGL (E) OVERHEAD COMM 24'-7"± AGL DocuSign Envelope ID: 0191F786-7273-498E-9298-A882149BC086DocuSign Envelope ID: AD4DAD06-1539-4E9D-9345-A186446DEE71 REVISIONS DATE MARCH 2015 IMPROVEMENT PLANS FOR MODUS OMT POLES CALIFORNIACUPERTINOFile: Scale: Proj. Engr: Checked: Drawn: Designed: Date: INSPECTOR: PUBLIC WORKS VOICE MAIL: DATE PROJECT ENGINEER NAME APPR.CITY DATEAPPR.DATE DESIGN BY DESIGN (408) 777-3104 KEVIN REIDEN FOR CITY OF CUPERTINO USE PROJECT # ___________ S A F E T Y O F A L L P E R S O N S A N D P R O P E R T Y ; T H A T T H IS R E Q U IR E M E N T S H A L L A P P L Y C O N T I N U O U S L Y A N D N O T B E L IM IT E D T O N O R M A L W O R K IN G H O U R S ; A N D T H A T T H E C O N T R A C T O R C O N T R A C T O R A G R E E S T H A T H E S H A L L A S S U M E S O L E A N D C O M P L E T E R E S P O N S IB IL IT Y F O R J O B S IT E C O N D IT IO N S D U R IN G T H E C O U R S E O F C O N S T R U C T IO N O F T H IS P R O J E C T , IN C L U D I N G S H A L L D E F E N D , I N D E M N I F Y A N D H O L D T H E O W N E R A N D T H E E N G IN E E R H A R M L E S S F R O M A N Y A N D A L L L IA B IL I T Y , R E A L O R A L L E G E D , IN C O N N E C T IO N W IT H T H E P E R F O R M A N C E O F W O R K S A F E T Y O F A L L P E R S O N S A N D P R O P E R T Y ; T H A T T H IS R E Q U IR E M E N T S H A L L A P P L Y C O N T I N U O U S L Y A N D N O T B E L IM IT E D T O N O R M A L W O R K IN G H O U R S ; A N D T H A T T H E C O N T R A C T O R C O N T R A C T O R A G R E E S T H A T H E S H A L L A S S U M E S O L E A N D C O M P L E T E R E S P O N S IB IL IT Y F O R J O B S IT E C O N D IT IO N S D U R IN G T H E C O U R S E O F C O N S T R U C T IO N O F T H IS P R O J E C T , IN C L U D I N G O N T H I S P R O J E C T , E X C E P T IN G F O R L IA B IL I T Y A R IS IN G F R O M T H E S O L E N E G L IG E N C E O F T H E O W N E R O R T H E E N G IN E E R . S H A L L D E F E N D , I N D E M N I F Y A N D H O L D T H E O W N E R A N D T H E E N G IN E E R H A R M L E S S F R O M A N Y A N D A L L L IA B IL I T Y , R E A L O R A L L E G E D , IN C O N N E C T IO N W IT H T H E P E R F O R M A N C E O F W O R K CUPERTINO CITY OFCONSULTANT: San Francisco, CA 94108 240 Stockton Street, 3rd Floor Modus, Inc.APPLICANT: E ST.1 955 NO SCALE $REQUEST San Jose, CA 95113 55 S Market St, Suite1200 WMH Corporation SHEET A-4 No. Exp. CIVIL R E G I S T E R ED PROFESS I O N A L E N G I N E E RST A T E O F CALIFORNIA LOUPE STEVE 63575 9/30/20 1 2#8 205’ 2#8 220’ 2 # 8 2 9 0 ’ 2 0 2 9 5 P. BATTH LEGEND: # # ELECTRICAL SERVICE CABINET EXISTING LUMINAIRE # CIRCUIT NUMBER# LUMINAIRE W/ CELLULAR EQUIPMENT P (HH)HAND-HOLE (NO PULL BOX) SPLICED CONNECTION POLE MOUNTED ELECTRICAL SERVICE POINT PULLBOX (NO SPLICE) - GATEWAY (MOUNTED TO POLE) STREETLIGHT COMMUNICATION EQUIPMENT MASTER PEU (MOUNTED TO POLE) OR UNDERGROUND ELECTRICAL SERVICE POINT CITY SERVICE BOX 8/05/2020 S. VOGTMAN S. VOGTMAN P. BATTH 1 2 0 2 8 1 C A _ S J _ C U P E R T I N O _ 3 1 8 120V* H A Z E L B R O O K D r N STELLING Rd G A R D E N G A T E D r C H R I S T E N S E N D r LAURETTA Dr CA_SJ_CUPERTINO_318 POLE 20281 + WATTAGE FOR PROPOSED CELLULAR EQUIPMENT IS BASED ON UTILIZING TWO RADIOS RATED AT 400W EACH. ** TYPICAL SERVICE FUSE RATED AT 30A USED FOR CALCULATIONS. * NO CITY SERVICE BOX LOCATED, VOLTAGE DROP CALCS USE PG&E POC AS SERVICE POINT LOCATION. LUMINAIRES CONTROLLED BY INDIVIDUAL PHOTOCELLS. 1 1 SC 4.83% 1 SC TO POS AND (E)(2) #10 CONDUCTORS FOR CITY POLE ID 20295 LUMINAIRE. SPLICE CONNECTION - SPLICE (N)(2) #4 CONDUCTORS WITH (E)(2) #8 CONDUCTORS (E)(2) #8 CONDUCTORS TO BE REPLACED IN (E) CONDUIT WITH (N)(2) #4 CONDUCTORS 1 LOCATION SERVICE POINT # CIRCUIT SIZE (FUSE) BREAKER ID POLE WATTAGE EQUIPMENT CELLULAR LUMINAIRE EXISTING LUMINAIRE PROPOSED AMPERAGE VOLTAGE DROP EXISTING PROPOSED EXISTING PROPOSED LAURETTA DR & CHRISTENSEN Dr 1 30A** 20281 800+50W ID - 1.0 7.7 0.73%7.52% 20295 -50W ID - (N) STREET LIGHT NODE DocuSign Envelope ID: 0191F786-7273-498E-9298-A882149BC086DocuSign Envelope ID: AD4DAD06-1539-4E9D-9345-A186446DEE71 5' - 6 " 2' - 0 " ELEVATION VIEW NOTCH AT LIGHT ARM SHEET METAL SKIRT PART # VVSP360S-AM-00 DIAMOND ENGINEERING SERVICES OR EQUIVALENT 2' - 2 " 1'-3" DIA. LIGHT POLE 5G ANTENNA, SEE DETAIL 6/D-1 3' - 4 " 10 " 7" WHITE NOTICE WHITE BACKGROUND BLACK SYMBOL BLACK LETTERING, TYP NOTES: 1. OUTDOOR RATED SELF ADHESIVE VINYL DECAL WITH UV PROTECTION. 2. POST SIGN 3'-0" BELOW PROPOSED ANTENNA. 3. CONTRACTOR TO CONFIRM SPECIFIC SIGN REQUIREMENTS WITH VERIZON WIRELESS. 4. DECAL SHALL FACE OUT THE STREET AND WHEN FEASIBLE AWAY FROM THE STREET, IF NO BUILDING WINDOW IS PRESENT WITHIN 25 FEET FACING THE EXISTING POLE. BLUE BACKGROUND 5.1" SIDE VIEW 21 . 2 " FRONT VIEW 21 . 2 " 8.1" 8.1" TOP VIEW ERICSSON STREETMACRO 6701 DIMENSIONS: 21.2" TALL x 8.1" WIDE x 5.1" DEEP WEIGHT: 31.0± LBS 5. 1 " SHUTDOWN PROTOCOL 6" Normal Shut-Down Protocols: 1.Call 800-264-6620 NOC 24HRS prior to schedule a shut-down day and time. 2.Give NOC the Node number . 3.On schedule day of shut-down, Put breaker switches in "OFF" position. 4.Call NOC when work is completed. Emergency Shut-Down Protocols: 1.Call 800-264-6620 NOC. 2.Give NOC the Node number . 3.Put breaker switches in "OFF" position. 4.Call NOC when work is completed. 8" NOTES: 1. SIGN PROVIDED BY GC MOUNTED TO OUTSIDE OF DISCONNECT COVER 2. CONTRACTOR TO NOTE SITE ID/ MARKET ID/ SITE NAME / PSLC ID STEEL MOUNT BRACKET AND PLATE LIGHT POLE 1/2" STAINLESS STEEL BANDS STEEL MOUNT BRACKET AND PLATE DISCONNECT SIDE VIEWFRONT VIEW TOP VIEW 1 1/2" STD PIPE NIPPLE 1/2" STAINLESS STEEL BANDS LIGHT POLE DISCONNECT 1/2" THREAD SEALING TAPE STEEL MOUNT BRACKET AND PLATE 1/2" STAINLESS STEEL BANDS SHUTDOWN 20 . 5 " 8.75" SIDE VIEW FRONT VIEW TOP VIEW TESCO DISCONNECT BOX WITH CT AND METER SOCKET COLOR: GRAY DIMENSIONS: 20.5" TALL x 8.75" WIDE x 4.25" DEEP TOTAL WEIGHT: PHASE.:4-WIRE VOLTAGE: 120/240 AMPACITY: 60 MAX 4.25" 4. 2 5 " SIGNAGE PER 8/D-1 SHUTDOWN PG&E SMART METER EATON DISCONNECT BOX DG222NRB 3. 2 5 " 6. 1 2 5 " 3" 4. 7 5 " 0.375 DRAWN BY: CHECKED BY:BPM APE IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT 0 08/12/20 100% CD REV DATE DESCRIPTION MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 APPROVED BY:LJB CA_SJ_CUPERTINO_318 VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 (NEAR) 21055 LAURETTA DR CUPERTINO, CA 95014 1 12/14/20 100% CD PLAN CHECK D-1 DETAILS 1NTS SCALE 8 9 ERICSSON 6701 10 11 12 5 6 NTS SCALE NTS SCALE 7 NTS SCALE 4 ANTENNA SHROUD & SKIRT NOTICE SIGNAGE SHUT-DOWN SIGN NTS SCALE NTS SCALE NTS SCALE NTS SCALE NTS SCALE NTS SCALE NTS SCALE 3NTS SCALE DISCONNECT DISCONNECT MOUNTING PULLBOX FIBER PULLBOX NOT USED NOT USED 3/8" X 3" HEX BOLT (2 EACH END) NOTES: LID 1. POLYMER CONCRETE CONSTRUCTION 2. STANDARD LOAD RATING 20,800 LBS 3. TWO (2) BOLT DOWN LOCATIONS 4. NON SKID SURFACE STANDARD 5. APPROXIMATE WEIGHT 104 LBS BOX 1. POLYMER CONCRETE CONSTRUCTION 2. STACKABLE FOOT 3. APPROXIMATE WEIGHT 150LBS BOLT DOWN TYP. OF (2) 37-5 / 8 " 26 " 18" 35-5 / 8 " 24 " 3" NON SKID SURFACE (STANDARD) 2"X8" NAMEPLATE RECESS LIFT PIN TYP. OF (2) NOT USED DocuSign Envelope ID: 0191F786-7273-498E-9298-A882149BC086DocuSign Envelope ID: AD4DAD06-1539-4E9D-9345-A186446DEE71