Loading...
BLD-2021-0678 Plans 07/16/21INDEX ABBREVIATIONS ELECTRICAL NOTES VICINITY MAP JURISDICTION NOTES REV BY DATE COMMENTS REV A NAME DATE COMMENTS REV B BP 6/16/2021 Layout altered & added equip. distance to prop. line REV C LJS 7/9/2021 Layout updated due to FSB. * * ** * * ** LICENSE GENERAL NOTES Phuong Devries 07/16/21 07/16/21 BLD-2021-0975 Haley McKee (E) DRIVEWAY 01' 32'16' Scale:1/16" = 1' PROPERTY PLAN c Phuong Devries 07/16/21 Front Of House (E) DRIVEWAY 3' FSB1'-6 " F S B 3' FSB3' FSB3' FS B 12" SB 1'-6 " FS B12" SB12 " S B 3' FSB1'-6" FSB1'-6" FSB3' FSB1'-6" FSB1'-6" FSB3' FSB1'-6" F S B 1'-6" FS B12" setback12" setback12 " s e t bac k 3' FSB1 2" SB 12" SB1 2 " S B 3' FS B3' FSB3' FS B3' FSB1'-6" F S B B CPitch4/12M P 1 Pitch4/12M P 2 Pitch4/12M P 3 Scale: 3/32" = 1' SITE PLAN 0 1'10' 21' LEGEND MP3 17° (4:12) 212 17° (4:12) 212 Comp Shingle 2 Stories MP2 19° (4:12) 212 19° (4:12) 212 Comp Shingle 2 Stories MP1 19 212 19 212 Comp Shingle 2 Stories #SSTAMPCA #ESTAMPCA c Phuong Devries 07/16/21 S1 SIDE VIEW OF MP3 NTS STORIES: ROOF AZI PITCH ARRAY AZI PITCH MP3 212 17 212 17 Comp Shingle 22x4 @ 24" OC 2x4 @24" OC RAFTER C.J. C S1 SIDE VIEW OF MP2 NTS STORIES: ROOF AZI PITCH ARRAY AZI PITCH MP2 212 19 212 19 Comp Shingle 22x4 @ 24" OC 2x4 @24" OC RAFTER C.J. B Scale: 1 1/2" = 1' STANDOFFS1 #SSTAMPCA Phuong Devries 07/16/21 #SSTAMPCA Phuong Devries 07/16/21 LICENSEMODULE SPECS INV 1 INVERTER SPECS GENERAL NOTES MAIN PANEL SPECS GROUND SPECS INV 2 INV 3 AC DC A B EGC GEC GNDGND A L2 L1 EGC GND 240V Inverter 1 IND EGC DC- DC+ DC- DC+ EGC DC- DC+ EGC DC- DC+ MP 2: 1x9 MP 3: 1x3 GD PV A POI 1 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC1 2 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC2 3 Vmp = VAC Imp= AAC 3 #ESTAMPCA c Phuong Devries 07/16/21 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN - Address: 817 Cottonwood Dr OPERATING VOLTAGE = 240V JB-95016040-00 Phuong Devries 07/16/21 LB-130089-10X Per Code: CEC 690.31.G.3 Label Location: (C)(IC)(CB) LB-050081-10X Per Code: CEC 690.13.B Label Location: (DC) (INV) 690_53_2017 Per Code: CEC 690.53 Label Location: (DC) (INV) LB-050082-10X Per Code: CEC 690.13.B Label Location: (AC) (POI) LB-040007-10X Per Code: CEC 690.54 Label Location: (AC) (POI) LB-040013-10X Label Location: (AC) LB-070005-10X Per Code: 690.13.B Label Location: (DC)(CB) LB-070039-10X_2017 Per Code: 705.12.B.2.3.b Label Location: (POI) LB_200127_10X Per Code: 705.12.B.2.3.c LB-040009-10X Per Code: 705.12.B.3 Label Location: (POI) LB-060046-10X Per Code: CEC 690.54; CEC 690.13.B Label Location: (POI) LB-101092-10X Per Code: 690.56 (C)(3) Label Location: RSD Switch LB-250002-34X Per Code: 690.56(C)(1)(a) Label Location: SolarEdge and,Delta M-Series and,Telsa Inverter (POI): Point of Interconnection (M): Utility Meter (LC): Load Center (INV): Inverter With Integrated DC Disconnect (IC): Interior Run Conduit (DC): DC Disconnect (D): Distribution Panel (CB): Combiner Box (C): Conduit (AC): AC Disconnect Label Set Phuong Devries 07/16/21 YIELD SECURITY ANTI PID TECHNOLOGY (APT) HOT-SPOT PROTECT (HSP) TRACEABLE QUALITY (TRA.QTM) ANTI LID TECHNOLOGY (ALT) Product and Performance Warranty Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.5 %. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID and Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. ZEP COMPATIBLETM FRAME DESIGN High-tech black Zep CompatibleTM frame, for improved aesthetics, easy installation and increased safety. A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. 1 APT test conditions according to IEC/TS 62804-1:2015, method B (−1500 V, 168 h) 2 See data sheet on rear for further information THE IDEAL SOLUTION FOR: Rooftop arrays on commercial and industrial buildings Q.PEAK DUO BLK-G6+ / SC 330-345 ENDURING HIGH PERFORMANCE Į [% / K]+ 0.04 ȕ [% / K] − 0.27 Ȗ [% / K]− 0.36 NMOT [°F] 109 ± 5.4 (43 ± 3 °C) 330 335 340 345 [W]330 335 340 345 [A]10.41 10.47 10.52 10.58 [V]40.15 40.41 40.66 40.92 [A]9.91 9.97 10.02 10.07 [V]33.29 33.62 33.94 34.25 [%]≥ 18.4 ≥ 18.7 ≥ 19.0 ≥ 19.3 [W]247.0 250.7 254.5 258.2 [A]8.39 8.43 8.48 8.52 [V]37.86 38.10 38.34 38.59 [A]7.80 7.84 7.89 7.93 [V]31.66 31.97 32.27 32.57 [V]1000 (IEC) / 1000 (UL) II [A DC]20 C (IEC) / TYPE 2 (UL) [lbs / ft2] 50 (2400 Pa) / 50 (2400 Pa)− 40 °F up to + 185 °F (− 40 °C up to + 85 °C) [lbs / ft2] 75 (3600 Pa) / 75 (3600 Pa) 3 See Installation Manual Certified UL 1703 (254141) Hanwha Q CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us MECHANICAL SPECIFICATION Format 68.5 × 40.6 × 1.57 in (including frame) (1740 × 1030 × 40 mm) Weight 47.4 lbs (21.5 kg) Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodized aluminum Cell 6 × 20 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98 × 1.26-2.36 × 0.59-0.71 in (53-101 × 32-60 × 15-18 mm), Protection class IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 43.3 in (1100 mm), (−) ≥ 43.3 in (1100 mm) Connector Stäubli MC4; IP68 Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product.Specifications subject to technical changes © Q CELLS Q.PEAK DUO BLK-G6+/SC_330-345_2019-11_Rev01_NAELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)MinimumPower at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP IMPP Voltage at MPP VMPP Efficiency1 Ș MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 MinimumPower at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP IMPP Voltage at MPP VMPP 1 Measurement tolerances P MPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2800 W/m², NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power during first year. Thereafter max. 0.54 % degradation per year. At least 93.1 % of nominal power up to 10 years. At least 85 % of nominal power up to 25 years. All data within measurement toleranc- es. Full warranties in accordance with the warranty terms of the Q CELLS sales organization of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m²) TEMPERATURE COEFFICIENTS Temperature Coefficient of I SC Temperature Coefficient of VOC Temperature Coefficient of PMPP Normal Module Operating Temperature PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS Protection Class Maximum Series Fuse Rating Fire Rating based on ANSI / UL 1703 Max. Design Load, Push / Pull (UL)3 Permitted Module Temperature on Continuous DutyMax. Test Load, Push / Pull (UL)3 QUALIFICATIONS AND CERTIFICATES UL 1703, CE-compliant, IEC 61215:2016, IEC 61730:2016, Application Class II, U.S. Patent No. 9,893,215 (solar cells) 200 400 600 800 1000 110 100 90 80RELATIVE EFFICIENCY [%]IRRADIANCE [W/m²]RELATIVE EFFICIENCYCOMPARED TO NOMINAL POWER [%]100 95 90 85 80 75 15 5 2 5200 10 YEARS 98 Q CELLS Industry standard for tiered warranties* Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 (as at: September 2014) 37.4" (950 mm) 68.5" (1740 mm) 4 × Fastening points (DETAIL A) Frame 6.06" (154 mm) 40.55" (1030 mm) 38.6" (981 mm) 1.57" (40 mm) 8 × Drainage opening 0.14" × 3.1" (3.6 mm × 8 mm) 6 × Grounding points ø 0.16" (4 mm) Label DETAIL A 0,472" (12 mm) 0.354" (9 mm)1.063" (27 mm) 15.6“ (395 mm) 7.09" (180 mm) 4 × Drainage opening ≥ 43.3" (1100 m m) ≥ 43.3" (1100 m m) Phuong Devries 07/16/21 DC- DC+ 1 GD · · · · · DC1 Phuong Devries 07/16/21 · · · · · DC1 DC- DC+ 1 GD Phuong Devries 07/16/21 TESLA.COM/ENERGY SOLAR INVERTER 411 mm 660 mm 158 mm Tesla Solar Inverter provides DC to AC conversion and integrates with the Tesla ecosystem, including Solar Panels, Solar Roof, Powerwall, and vehicle charging, to provide a seamless sustainable energy experience. KEY FEATURES • Integrated rapid shutdown, arc fault, and ground fault protection • No neutral wire simplifies installation • 2x the standard number of MPPTs for high production on complex roofs NA 2021-6-1 ENVIRONMENTAL SPECIFICATIONS Operating Temperature –30°C to 45°C (–22°F to 113°F)4 Operating Humidity (RH) Up to 100%, condensing Storage Temperature –30°C to 70°C (–22°F to 158°F) Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Rating Type 3R Ingress Rating IP55 (Wiring compartment) Pollution Rating PD2 for power electronics and terminal wiring compartment, PD3 for all other components Operating Noise @ 1 m < 40 db(A) nominal, < 50 db(A) maximum ELECTRICAL SPECIFICATIONS MODEL NUMBER 1534000-xx-y 1538000-xx-y OUTPUT (AC)3.8 kW 7.6 kW Nominal Power 3,800 W 7,600 W Maximum Apparent Power 3,328 VA at 208 V 3,840 VA at 240 V 6,656 VA at 208 V 7,680 VA at 240 V Maximum Continuous Current 16 A 32 A Breaker (Overcurrent Protection)20 A 40 A Nominal Power Factor 1 - 0.9 (leading / lagging) THD (at Nominal Power)<5% INPUT (DC) MPPT 2 4 Input Connectors per MPPT 1-2 1-2-1-2 Maximum Input Voltage 600 VDC DC Input Voltage Range 60 - 550 VDC DC MPPT Voltage Range 60 - 480 VDC1 Maximum Current per MPPT (Imp)13 A Maximum Short Circuit Current per MPPT (Isc)15 A COMPLIANCE INFORMATION Grid Certifications UL 1741, UL 1741 SA, IEEE 1547, IEEE 1547.1 Safety Certifications UL 1699B, UL 1741, UL 1998 (US) Emissions EN 61000-6-3 (Residential), FCC 47CFR15.109 (a) MECHANICAL SPECIFICATIONS Dimensions 660 mm x 411 mm x 158 mm (26 in x 16 in x 6 in) Weight 52 lb3 Mounting options Wall mount (bracket) 3 Door and bracket can be removed for a mounting weight of 37 lb. 4 For the 7.6 kW Solar Inverter, performance may be de-rated to 6.2 kW at 240 V or 5.37 kW at 208 V when operating at temperatures greater than 45°C. 1 Maximum current. 2 Cellular connectivity subject to network operator service coverage and signal strength. PERFORMANCE SPECIFICATIONS Peak Efficiency 98% at 208 V 98.1% at 240 V 98.4% at 208 V 98.6% at 240 V CEC Efficiency 97.5% at 208 V 97.5% at 240 V 97.5% at 208 V 98.0% at 240 V Allowable DC/AC Ratio 1.7 Customer Interface Tesla Mobile App Internet Connectivity Wi-Fi (2.4 GHz, 802.11 b/g/n), Ethernet, Cellular (LTE/4G)2 AC Remote Metering Support Wi-Fi (2.4 GHz, 802.11 b/g/n), RS-485 Protections Integrated arc fault circuit interrupter (AFCI), Rapid Shutdown Supported Grid Types 60 Hz, 240 V Split Phase 60 Hz, 208 V Wye Required Number of Tesla Solar Shutdown Devices per Solar Module See Solar Shutdown Device Requirements per Module on page 3 Warranty 12.5 years TESLA.COM/ENERGY SOLAR SHUTDOWN DEVICE The Tesla Solar Shutdown Device is part of the PV system rapid shutdown (RSD) function in accordance with Article 690 of the applicable NEC. When paired with the Tesla Solar Inverter, solar array shutdown is initiated by any loss of AC power. 650 mm 150 mm 125 mm 250 mm M4 Screw M8 Bolt Nail / Wood Screw 22 mm ENVIRONMENTAL SPECIFICATIONS Ambient Temperature -40°C to 50°C (-40°F to 122°F) Storage Temperature –30°C to 70°C (–22°F to 158°F) Enclosure Rating NEMA 4 / IP65 ELECTRICAL SPECIFICATIONS Nominal Input DC Current Rating (IMP) 12 A Maximum Input Short Circuit Current (ISC) 15 A Maximum System Voltage 600 V DC COMPLIANCE INFORMATION Certifications UL 1741 PVRSS PVRSA (Photovoltaic Rapid Shutdown Array) MECHANICAL SPECIFICATIONS Electrical Connections MC4 Connector Housing Plastic Dimensions 125 mm x 150 mm x 22 mm (5 in x 6 in x 1 in) Weight 350 g (0.77 lb) Mounting Options ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw RSD MODULE PERFORMANCE Maximum Number of Devices per String 5 Control Power Line Excitation Passive State Normally open Maximum Power Consumption 7 W Warranty 25 years PVRSA RSD Initiation Method Loss of AC power Compatible Equipment Tesla Solar Inverter SOLAR SHUTDOWN DEVICE REQUIREMENTS PER MODULE The following modules have been certified as part of a PV Rapid Shutdown Array (PVRSA) when installed together with the Tesla Solar Inverter and Tesla Solar Shutdown Devices. See the Tesla Solar Inverter Installation Manual for guidance on installing Tesla Solar Inverter and Solar Shutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Hanwha Q.PEAK DUO BLK-G5 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G6+1 Solar Shutdown Device per 3 modules NA 2021-6-1 Phuong Devries 07/16/21 FLASHING INSERT ZS COMP DATASHEET 2 Listed to UL 2703 and UL 2582 for Wind Driven Rain Part #850-1628 SPECIFICATIONS Designed for pitched roofs. Installs in portrait and landscape orientations. Engineered for spans up to 72” and cantilevers up to 24”. ZS Comp has a UL 1703 Class “A” Fire Rating when installed using modules from any PDQXIDFWXUHUFHUWL¿HGDV³7\SH´RU³7\SH´ Attachment method UL listed to UL 2582 for Wind Driven Rain. ZS Comp supports 50 psf (2400 Pa) front and up to 72 psf (3450 Pa) rear side design load rating for Portrait module orientation per UL 2703. ZS Comp supports 50 psf (2400 Pa) front side and up to 72 psf (3450 Pa) rear side design load rating for Landscape module orientation. Engineered for compliance with ASCE 7-05, 7-10, and 7-16 wind load requirements. Zep wire management products listed to UL 1565 for wire positioning devices. ZS Comp grounding products are listed to UL 2703 and UL 467. ZS Comp bonding products are listed to UL 2703. DESCRIPTION PV mounting solution for composition shingle roofs. Works with all Zep Compatible Modules. Auto bonding UL-listed hardware creates structural and electrical bond. ROOFING SYSTEM SPECIFICATIONS MOUNTING BLOCK CAPTURED WASHER LAG Listed to UL 2703 Part #850-1633 Part #850-1631-002 and #850-1631-004 ZS COMP DATASHEET 3 GROUND ZEP LEVELING FOOT DC WIRE CLIP HOME RUN CLIP Listed to UL 1565 Part #850-1510 ARRAY SKIRT END CAP Listed to UL 2703 Part #850-1511 Listed to UL 2703 Part #850-1613 Listed to UL 2703 Part #850-1608 Listed to UL 2703 Part #850-1606 Listed to UL 2703 Part #850-1586 (Left) Part #850-1588 (Right) INTERLOCKSKIRT GRIP Listed to UL 2703 Part #850-1397 Listed to UL 1565 Part #850-1509 Listed to UL 2703 Part #850-1281 HYBRID INTERLOCK Phuong Devries 07/16/21 PVRSA Model: ZS Rapid Shutdown Array (Applicable to ZS Comp, ZS Span, ZS Ramp, and ZS Seam) Category QIJR, Report Date: 2021-03-05 Table of Essential Elements Function Manufacturer Model No. Firmware Versions and Checksums Certification Standard PVRSE Mid Circuit Interrupter (MCI)Tesla MCI-1 15503792 N/A UL 1741 PVRSE Inverter Tesla 7.6 kW: 15380002 3.8 kW: 15340002 V1, D85CAB80 V1, 8A3CA3F2 UL 1741, 1998 PVRSS/PVRSE PV Module Hanwha Q- CELLS Q.PEAK DUO BLK-G5/SC315 Q.PEAK DUO BLK-G5/SC320 Q.PEAK DUO BLK G6+/SC330 Q.PEAK DUO BLK-G6+/SC335 Q.PEAK DUO BLK-G6+/SC340 Q.PEAK DUO BLK-G6+/SC345 N/A UL 1703 Interlock Tesla ZEP 850-1613-001 ZEP 850-1388-001 ZEP 850-1281-001 N/A UL 2703 Ground Zep Tesla ZEP 850-1511-001 ZEP 850-1172-002 N/A UL 467 UL 2703 DC Wire Clip Tesla ZEP 850-1509-001 ZEP 850-1448-001 N/A UL 1565 Homerun Wire Clip Tesla ZEP 850-1510-001 UL 1565 PVRSA Initiator1 (See installation requirements below) Non-Specific N/A N/A N/A 1 Dedicated PV system AC circuit breaker or AC disconnect switch, labeled per NEC 690.12 requirements. 2 Applies to variations of this part number with suffix of two numbers and one letter.. Note: PVRSA installation requirements may reduce the effective equipment and component ratings below the individual equipment and component PVRSE ratings in order to achieve PVRSA shock hazard reduction requirements. PVRSA Installation Requirements Max System Voltage 600 Vdc Max Array Internal Voltage After Actuation 165 Vdc (cold weather open circuit) Max Series-Connected Panels between MCIs:3 Other Installation Instructions: 1. An MCI must be connected to one end of each series string or sub-array string. 2. Verification that MCIs are installed with 3 or fewer modules between MCIs shall be documented for inspection, by voltage measurement logs and/or as-built string layout diagrams. 3. The dedicated PV system AC circuit breaker or PV system AC disconnect switch shall serve as the PVRSA initiator and shall be sized and installed in accordance with NEC requirements. The specific part shall be identified on the as-built system drawings. Certification Mark of UL on the installation instructions is the only method provided by UL to identify products manufactured under its Certification and Follow-Up Service. The Certification Mark for these products includes the UL symbol, the words "CERTIFIED" and "SAFETY," the geographic identifier(s), and a file number.” PVRSA Model: Solarglass Roof Rapid Shutdown Array Category QIJR, Report Date: 2021-03-05 Table of Essential Elements Function Manufacturer Model No. Firmware Versions and Checksums Certification Standard PVRSE Mid Circuit Interrupter (MCI)Tesla MCI-1 15503792 N/A UL 1741 PVRSE Inverter Tesla 7.6 kW: 15380002 3.8 kW: 15340002 V1, D85CAB80 V1, 8A3CA3F2 UL 1741, 1998 PVRSS/PVRSE PV Module Tesla SR60T1 N/A UL 61730 Diode Harness Tesla SRDTH N/A UL 9703 PV Wire Jumper(s) Tesla SR-BJ2X SR-BJ3X SR-BJ4X SR-BJMini N/A UL 9703 Pass-Through Box Tesla SRPTB-4 N/A UL 1741 PVRSA Initiator1 (See installation requirements below) Non-Specific N/A N/A N/A 1 Dedicated PV system AC circuit breaker or AC disconnect switch, labeled per NEC 690.12 requirements. 2 Applies to variations of this part number with suffix of two numbers and one letter. Note: PVRSA installation requirements may reduce the effective equipment and component ratings below the individual equipment and component PVRSE ratings in order to achieve PVRSA shock hazard reduction requirements. PVRSA Installation Requirements Max System Voltage 600 Vdc Max Array Internal Voltage After Actuation 165 Vdc (cold weather open circuit) Max Series-Connected Panels between MCIs:10 Other Installation Instructions: 1. An MCI must be connected to one end of each series string or mounting plane sub-array string. 2. Verification that MCIs are installed with 10 or fewer modules between MCIs shall be documented for inspection, by voltage measurement logs and/or as-built string layout diagrams. 3. The dedicated PV system AC circuit breaker or PV system AC disconnect switch shall serve as the PVRSA initiator and shall be sized and installed in accordance with NEC requirements. The specific part shall be identified on the as-built system drawings. Certification Mark of UL on the installation instructions is the only method provided by UL to identify products manufactured under its Certification and Follow-Up Service. The Certification Mark for these products includes the UL symbol, the words "CERTIFIED" and "SAFETY," the geographic identifier(s), and a file number.” Phuong Devries 07/16/21