Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
14080095
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 7589 BARNHART PL CONTRACTOR:SOLARCITY PERMIT NO: 14080095 OWNER'S NAME: KUO CH1NG-HORNG AND Ll L 3055 CLEARVIEW WAY DATE ISSUED:08/13/2014 OWNER'S PHONE: 4084461367 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL COMMERCIAL ❑ INSTALL 20 PANEL PV SYSTEM ON SFDWL ROOFTOP License Class C 10 -C 4 4 Lic.# FS- 04 5.IKW Contractor Date / hereby affirm that I am licensed under the provisions of hapte'r 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$10000 1 have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the tabor Code,for the performance of the work for which this APN Number:36616079.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that l have read this application and state that the above information is PERMIT E IRES IF WOR IS NOT STARTED correct.1 agree to comply with all city and county ordinances and state laws relating WITHIN 1 DAYS OF PER IT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS F M LA CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the �� granting of this permit. Additionally,the a pI cant understands and will comply Issued by: Date: with all non-point source re ulations p e Cupertino Municipal Code,Section 9.18. _ RE-ROOFS: Signature Date y All roofs shall be inspected prior to any rooting material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: ereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALI.ROOF COVERINGS TO BE CLASS"A" OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(See.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will 1 hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District performance of the work for which this permit is issued. will maintain compliance with the Cupertin Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 2 .05 5533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Owner or authorized agent: Dater' I certify that in the performance of the work for which this permit is issued,l shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,l CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,l must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's.Address I certify that I have read this application and state that the above information is correct, l agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18 Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION 12 COMMUNITY DEVELOPMENT DEPARTMENT- BUILDING DIVISION 10300 TORRE AVENUE-CUPERTINO, CA 95014-3255 - A CUPERTINO (408) 777-3228• FAX(408)777-3333• buildingCc)-cupertino.org �l l6� J PROJECT ADDRESS [5 7�V' (n �aY D I, �Y'}1 11 7,kPN# OWNER NAME PHONE ((/(3( E-MAIL STREET ADDRESS ��Y�I lG1 f j f CITY, STATE,ZIP/ �4 1.`p/k p, r, A ,c1ro ref FAX CONTACT NAME 6.cy- x ian1 O c PHONE(/ 'ro) '7 s l` O0 /a Off`E-MAIJL I I STREET ADDRESS 3ctl kosfa C�if� y� IVA CITY,STATE,'PZIP f�0i,lt � C11),,CA �-[� FAX ❑ OWNER ❑ OWNE/R-BUILDER ❑ OWNER AGENT ` CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME n t LICENSE NUMBER LICENSE BUS.LIC X i1aCZT� n GjqSo 10 1 7 COMPANY NAME ( E-MAIL �CL1 FAX Cvf STREET ADDRESS CITY,STATE,ZIP �� V > PHONE \ 3055 �'_�ca tiY i«J t� Accn le�icC�1 CA, �`f 6so) ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC H COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF ❑ SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE. ❑ Commercial URBAN INTERFACE.AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes ❑ NO SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANE/_S: NUMBER OF PANELS/UNITS: 9 KILOWATTS: TOT`A�L VALUATION JC ,CCC C ,CCC DESCRIPTION OF WORK R S L� C ) fOlD 1 I Cl �C'L an e—Is (,s-. I k"i > j �� �0�-v / i I� �ll-�Y1 MOLV�1��-ti ,cj:� ..RECEIVED BY: By my signature below,I certify to each of the following: [am the property owner or authorized agent to act on the property own ' behalf. I have read this application and the information[have rovided is correct. I have read the Description of Work and verify it is accurate. I agree to comp y wi dii3pptica e ocal ordinances and state laws relating to ul di co ction. I authorize representatives of Cupertino to enter the above-ideentti)ifi propertyfor inspection purposes. Signature of Applicant/Agent: Date: © `75 I S( Iq SUPPLEMEN AL INFORMATION REQUIRED OFFICE USE ONLY ❑ OVER-THE-COUNTER c. } F' ❑ EXPRESS tL U Lj STANDARD J J ❑ LARGE c. ❑ MAJOR PVApp_2012.doc revised 06/20/12 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 7589 barnhart pi DATE: 08/13/2014 REVIEWED BY: Mendez APN: )Q "VALUATION: 1$10,000 °PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RES USE: PERMIT TYPE: WORK install 20panel pv system on sfdwl rooftop 5.1 kw SCOPE Ll Ll _L_ NOTE: This estimate does not include fees due to other Departments(i.e.Planning,Public Works, Fire,Sanitary Sewer District,School District,etc). Thesefees are based on the prelimina information available and are only an estimate. Contact the De t or addn'l info. FEE ITEMS (Fee Resolution 11-053 Eft%1%13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 0 # Alternative Energy System Suppl. PC Fee: Q Reg. Q OT 0.0 hrs $0.00 $236.00 IPHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee-(F) Reg. Q OT 0.0 1 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 T__T__ 0 Work Without Permit? ® Yes (2) No $0.00 G Advanced Planning Fee: $0.00 Select a Non-Residential (2) Building or Structure i Strom Motion Fee: IBSEISMICR $1.30 Select an Administrative Item Bldy,Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $2.30 $236.00 TOTAL FEE: $238.30 Revised: 07/10/2014 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING FLASHING WILL BE PAINTED TO MATCH EXTERIOR AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE CONC CONCRETE HAZARDS PER ART. 690.17. DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY (E) EXISTING PHASE AND SYSTEM PER ART. 210.5. EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY-RECOGNIZED TESTINGLNS C1�E FSB Fire Set-Back LABORATORY SHALL LIST ALL EQUIPMENT IN p oPcw 13, CUPERTINO GALV GALVANIZED COMPLIANCE WITH ART. 110.3. EN Gilding Department GROUNDING ELECTRODE CONDUCTOR 4. CIRCUITS OVER 250V TO GROUND SHALL Ir ( `� GND GROUND COMPLY WITH ART. 250.97, 250.92(B) HDG HOT DIPPED GALVANIZED 5. DC CONDUCTORS EITHER DO NOT ENTER UA 13 3 2014 I CURRENT BUILDING OR ARE RUN IN METALLIC RACEWAYS OR o NY G , CUrV,,,,JNrY DEVELOPMENT DEPARTMENT Imp CURRENT AT MAX POWER ENCLOSURES TO THE FIRST ACCESSIBLE DC BUILDING DIVISION-CUPERTINO ��Mp�i��� Isc SHORT CIRCUIT CURRENT DISCONNECTING MEANS PER ART. 690.31(E). r� kVA KILOVOLT AMPERE 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN A M OVED pA' r e4-ewea By kW KILOWATT RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY This set of plans and specifications MUST be kept at theDgcf • LBW LOAD BEARING WALL UL LISTING. job site during construction. it is unlawful to mil-.a any BLS' 1 MIN MINIMUM 7. MODULE FRAMES SHALL BE GROUNDED AT THE chancss or a��ft u,ations on same,or to deviate (N) NEW UL-LISTED LOCATION PROVIDED BY THE therefrom,without approval from the Building Official. ANT NEUT NEUTRAL MANUFACTURER USING UL LISTED GROUNDING NTS NOT TO SCALE HARDWARE. The stamping of this plan and specifications SHALL NOT OC ON CENTER 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE be held io permit or to approval of the vicintion 13 2014 PL PROPERTY LINE BONDED WITH EQUIPMENT GROUND CONDUCTORS AND of any provisions of ai y Ordnance or State Law. POI POINT OF INTERCONNECTION GROUNDED AT THE MAIN ELECTRIC PANEL. PV PHOTOVOLTAIC 9. THE DC GROUNDING ELECTRODE CONDUCTOR BY SCH SCHEDULE SHALL BE SIZED ACCORDING TO ART. 250.166(B) & DATE ,� _ gY� SS STAINLESS STEEL 690.47. PERMIT N0. i STC STANDARD TESTING CONDITIONS �- TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT i 3R NEMA 3R, RAINTIGHT PVl COVER SHEET PV2 SITE PLAN • PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES PV5 THREE LINE DIAGRAM Cutsheets Attached CA # 888104 1. THIS SYSTEM IS GRID-INTERTIED VIA A C-10 UL-LISTED POWER-CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. 4. ALL WORK TO BE DONE TO THE 2013 MODULE GROUNDING METHOD: * CALIFORNIA BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. s • REV BY DATE COMMENTS AHJ: Cupertino 5. ALL ELECTRICAL WORK SHALL COMPLY WITH REV NAME DATE COMMENTS THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. UTILITY: Pacific Gas and Electric Company J;B-9 5 0 3 4 7 8 0 0 PREMISE OWNER: DESMIPTIw:: DESIGN: CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: K U O, CHIN G CONTAINED SHALL NOT BE USED FOR THE - \\, � KUO RESIDENCE Cesar Giron � NOR BENESHALL IT BFIT OF EDISCLOSEDIN WHOLE EXCEPT E OR RCIN MOUNTING SYSTEM: 7589 BARNHART PL Wiksolar ity. PART To OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C 5.1 KW PV ARRAY ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES CUPERTINO, CA 95014 3055 CIearview Way THE SALE AND USE OF THE RESPECTIVE (20) Advantage Module SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN MVERTER PAGE NAME SHEET: �' DATE. L(650)San Mae CA (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE5000A-US-ZB-U L (408) 446-1367 COVER SHEET PV 1 8/8/2014 (888)-SOL-CITY(765-2489)www.solarcity.aam PITCH: 21 ARRAY PITCH:21 MP1 AZIMUTH:184 ARRAY AZIMUTH: 184 MATERIAL:Comp Shingle STORY: 2 Stories PITCH: 21 ARRAY PITCH:21 MP2 AZIMUTH:94 ARRAY AZIMUTH:94 MATERIAL:Comp Shingle STORY: 2 Stories PITCH: 21 ARRAY PITCH:21 MP3 AZIMUTH:274 ARRAY AZIMUTH:274 MATERIAL:Comp Shingle STORY: 2 Stories Im I� P� I C 5/ 3 3 FSS m a B LEGEND zt/s 31 FSB 44d1 O (E) UTILITY METER & WARNING LABEL CIO I ° I�� INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS B DC w. JUNIQNCOR � BOX & LABELS U�ETNO DISTRI 9W0Pt A9VLS S E In f �?il}�•;T 'q ��y IL6AU ATNik WARNING LABELS Inv , �E I � EG r 6EDI�A �i11fLR --- viewe�f�ADOF ��COATT0148'� O CONDUIT RUN ON EXTERIOR ___ CONDUIT RUN ON INTERIOR — GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L.'J Front Of House SITE PLAN TOTAL ARRAY AREA (SF): 360 Scale: 1/8" = 1' E TOTAL ROOF AREA (SF): 2505 w TOTAL ARRAY AREA IS a 14.36 0 1' 8' 16' PERCENT OF TOTAL ROOF AREA s CONFIDENTIAL— THE INFORMATION HEREIN FINE J B-9503478 �� PREMISE°� DE�'Pn0N: DESIGN: ■ CONTAINED SHALL NOT BE USED FOR THE KUO, CHING KUO RESIDENCE Cesar Giron BENEFIT OF ANYONE EXCEPT SOLARCITY INC., EM: ' �,Solar � ,�/ NOR SHALL IT BE DISCLOSED IN WHOLE OR INount Type C 7589 BARNHART PL J 5.1 KW PV ARRAY ►�, • PART IZ OTHERS OUTSIDE THE RECIPIENTS CU P E R TI N 0, CA 95014 30�CI way ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE antage Module PAGE MALE SHEET: REV DATE Son Mateo,CA 9M02 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. GE SE5000A-US-ZB-U (408) 446-1367 SITE PLAN PV 2 8/8/2014 (8B8)-SCI-CITY(765-2489)ww■.solarcny.com S1 S1 » 2' 2' 10'-10" (E) LBW (E) LBW SIDE VIEW OF MP2 NTS SIDE VIEW OF MP3 NTS 6 C MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP3 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" LANDSCAPE 72" 24" PORTRAIT 4811 2011 PORTRAIT 48" 20" RAFTER 2X6 @ 24 OC ROOF AZI 94 PITCH 21 STORIES: 2 RAFTER 2X6 @ 24 OC ROOF AZI 274 PITCH 21 STORIES: 2 ARRAY AZI 94 PITCH 21 ARRAY AZI 274 PITCH 21 C.J. 2X6 @24" OC Comp Shingle C.J. 2x6 @24" OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE S1 ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. » ZEP COMP MOUNT C ZEP FLASHING C (3) (3) INSERT FLASHING. 16'-1» -, ' < CUPERTINO ME Suilding Department (E) COMP. SHINGLE LL (1) (4) PLACE MOUNT. (E) LBW � ..��-;! (E) ROOF DECKING � (2) � I ��� � 2014 5/16" DIA STAINLESS (5) (5) INSSEALINGALL GWAOLT SHER.NTH A SIDE VIEW O F M P 1 N PZ STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES EVIE1tiEG FVK CODE COMPZIfh�iC;E WITH SEALING WASHER C(6) INSTALL LEVELING FOOT WITH � BOLT & WASHERS. MPJ X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER RevP*T5% (2-1/2" EMBED, MIN) LANDSCAPE 64" 24" (E) RAFTER STANDOFF PORTRAIT 64" 20" S1 RAFTER 2X10 @ 16" OC ROOF AZI 184 PITCH 21 STORIES: 2 1 ARRAY AZI 184 PITCH 21 Scale: 1 1/2" = 1' C.J. 2x10 @24" OC Comp Shingle CONFIDENTIAL— THE INFORMATION HEREIN ,TOB NUMBER: JB-9503478 00 PREMISE OWNER: DESORPTION: DESIGN: CONTAINED SHALL NOT E USED FOR THE KUO, CHING KUO RESIDENCE Cesar Giron SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �•., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 7589 BARNHART PL 5.1 KW PV ARRAY ip PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES. C U P E R TI N 0 CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH , 3055 Cieanier Way THE SALE AND USE OF THE RESPECTIVE (20) Advantage Module SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAYS SHEET: REV: DATE Son Mateo,CA 94402 PERMISSION OF SOLARCITY INC. INVRTER T:(650)638-1028 F(650)638-1029 SOLAREDGE SE50OOA—US—ZB—U (408) 446-1367 STRUCTURAL VIEWS PV 3 8/8/2014 (888)—SOL—CITY(765-2489)www.solarcitycom UPLIFT CALCULATIONS 013.ft 14 V-';".',iSo1arGty. SleekMaunt�'' PY System Structural Desian Software Rlsk • - _ II Wo . 011 Roof Cotn�Roof Roof PV (Module OrWMUon Pa talt Jog_.. com PV 1ModWle Wk11}t �` t4x& low Gl ourtid SI tGW L vts d yP9 Ai�GE Tabtst7-1 9rtbw Oren 1 . ASM Ekm 7:41 10 Bask Wt V. 110 mpFt Flg 26 5 lA; Rif Gebl� t iofi 3o.4•2Aj8e sA/8 1 A 17:6 sf IBC 1509.7.1 _.. .. . 1 000 sic k Ika eSk lei 0.45 Table 30.3-1. xi_ wa Wind DImbor W ity Fa¢Oor Kti. 085 Sectlorl 266-1_ _. Vekxlty p mmm qh q_M002W(1Ca)(Kzt (Kd)W-2) ' EWnticn 30.2-1 ext cf, r�soA- —&" WOW ire — 3M4-1 lit lo :L6A) E A CUPERTINO R1loivaflle39' Building Department J ^►a 1 3 2014 PY . . t7ebel 3 �- 3�= EWE Ffl CODE COMPLIANCE Uplift of surdoff T-VOW 500 lbs AIWL Mmc AQaWatde Stax S�, Wg Pbl'iraR W ,r bff 657 h PV LDW Ubd y44y.,. W-PA! 3 . ft oFSfoff T-all" Ar CONFIDENTIAL- THE(FORMATION HEREBY - �—im wAm- PRETIIISE DNER DESCRPTIDIk DESN;ft c�+rAr�En-slaL�frureE usEo -TTiE _Q - - t1�fi0 DUCE --- Glut► N�SWIL II'BE o a SE01�«F oft IN MOMW Mount 7589 BARNHART PL PART To 07HERS WTsnE THE RECIP11ENT'S Com Mount T e C 5.1 KW PV ARRAY i sowcfty. ORGANIZATION,EXCEPT IN CONNECTION WITH YOMES: CUPERTIN0, CA 95014 THE SALE AND USE OF THE RESPECnrE 20 Advantage Module Ge Im CA Nhy SDLAMW EWP10N 1ffNT, 01HWT THE MRITTEII PAM NNE: S M. REV DATE T.-(650)son MQ F(e9s4o4)�2saa-�o� "ISOF saaRaTY INC �M SOLAREDGE SE5000A-US-ZB-U (408) 446-1367 UPLIFT CALCULATIONS PV 4 8/8/2014 (88B}SOL�nr(765-2489)www.wW�� GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number: Inv 1: DC Ungrounded FINV —(1)SOLAREDGE #�SSE5000A—US—ZB—U LABEL: A —(20)Advantage Module CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:1009141914 Inverter, 5000W, 24OV, 97.59'4 w/Unifed Disco and ZB, AFCI PV Module; 255W, Poly, 60cell, Blck Frame, White Bcksht, ZEP C-10 Underground Service Entrance Voc: 37,7 Vpmax: 30.2 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E) 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 20OA/2P 3 SOLAREDGE SE5000A-US-ZB-U (E) LOADS L1 2aov SolarCity L2 N 2 A I 3OA/2P EGa DC. Dc• A --——————————————————————————————————————————————— — GEC ——— N DG DC- 1 n9(s)Of 20 On MP2,MP3, 1 B I I�I I I I N I I EGCIGEC — Z Z c, --- GEC --� TO 120/240V SINGLE PHASE UTILITY SERVICE I I I Voc* = MAX VOC AT MIN TEMP O1 (1)CUTLER—HAMMER /BR230 PV BACKFEED BREAKER /f, A Breaker, 30A/2P, 2 Spaces /,1 1)S2x2 STRINGS, 4 SIRING JD, GROUNDED BOX DC —(1)Ground Rod; 5/8' z 8', Copper 2x2 S1R�GS, UNFUSED, GROUNDED PV (20)SOLAREDGE�300-2NA4AZS PowerBox ptimizer, 30OW, H4, DC to DC, ZEP -.�- .:UPE R NO � i AWG /10, THWN-2, Black 1 AWG /10, THWN—2, Black Voc* =500 VDC Isc =15 ADC (2 AWG#It,PV-."RE,'Plack 9Wtdi9&PtIPWftWQW5 ADC O Icn� (1)AWG /10, THWN-2, Red O (1)AWG /10, THWN-2, Red Vmp =350 VDC Imp=14.38 ADC O (1)AWG/'I(), Solid Bad Copper EGC Vmp =350 VDC Imp=14.38 ADC LL LL(1)AWG /10, THWN-2, White NEUTRAL VmP =240 VAC Imp=20.83 AAC (!)AN /10 1HWN-2..Green EGC. . . —(1)Condgit_Kit..3 .FAIT . . . . . . .7.0 AWG A.THWN-2,.Gre . . EGC/GEC-0).CondUlt.Kit:.3/4'.EMT. . . . . . . . . . t`. :.�r . . . . . . . . . . . . . . . . . . . r_; -.0f CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9503478 0 0 PREMISE OYNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BEE USED FOR THE KUO, CHING KUO RESIDENCE Cesar Giron SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 7589 BARNHART PL 5.1 KW PV ARRAY 6 • PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES ' CUPERTINO CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH , 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (20) Advantage Module SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DAIS San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER' T:(650)638-1028 F:(650)638-1029 SOLAREDGE SE5000A-US-ZB-U (408) 446-1367 THREE LINE DIAGRAM PV 5 8/8/2014 (888)-SOL-CITY(765-2489)www.solarcity.com WARNING:PHOTOVOLTAIC POWER SOURCE PV SYSTEM WARNING Label Location: Label Location: Label Location: Per Code: DISCONNECT FOR • - CRC R331.2UTILITY OPERATION ELECTRIC SHOCK HAZARD • THE DC CONDUCTORS OF THIS Label Location: PHOTOVOLTAIC SYSTEM ARE • BE USED WHEN PHOTOVOLTAIC DC MAYBEOINVERTERIS ENERGIZED DISCONNECT UNGR• D ED CEC 690.14.C.2 WARNING Code:Per _ • • ELECTRIC SHOCK HAZARD CEC ••� '• DO NOT TOUCH TERMINALS MAXIMUM POWER TERMINALS ON BOTH LINE AND POINT CURRENT(Imp)_A Per ••- LOAD SIDES MAY BE ENERGIZED MAXIMUM POWER- VCEC 690 IN THE OPEN POSITION POINT VOLTAGE(Vmp) MAXIMUM SYSTEM_V VOLTAGE(Voc) SHORT-CIRCUIT CURRENT(Isc) A Label • • WARNING (POI)Code:Per INVERTER OUTPUT CEC � � CONNECTION .•- • • DO NOT RELOCATE (CB) Per THIS OVERCURRENT _ •dDEVICE ELECTRICAL SHOCK HAZARD 690.17 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITIONLabel L• • DC VOLTAGE IS PHOTOVOLTAIC POINT OF '• Per ALWAYS PRESENT WHEN INTERCONNECTION SOLAR MODULES ARE Code: EXPOSED TO SUNLIGHT WARNING:ELECTRIC SHOCK CEC •. 690.17 HAZARD.DO NOT TOUCH TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION.FOR SERVICE Label Location: DE ENERGIZE BOTH SOURCE AND MAIN BREAKER. WARNING Per ,,_ PV POWER SOURCE h4AXIMUM AC A ELECTRIC SHOCK HAZARD 690.5(C) OPERATING CURRENT _ IF A GROUND FAULT IS INDICATEDMAXIMUM AC NORMALLY GROUNDED OPERATING VOLTAGE _ V CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED BuildingCUPERTING Department Label • • LabelLocation: <` AUG 13 2014 PHOTOVOLTAIC AC '• CAUTION Per Code:'• .` ' ,isconnect _ Code: PHOTOVOLTAIC SYSTEM • DISCONNECT CIRCUIT ISBACKFED 64 •.� :. ri Conduit(DC): DC Disconnect (IC): Interior Run Label .•- IntegratedInverter DC Disconnect MAXIMUh4 AC _ q • CAUTION (POI) (LC): Load Center OPERATING CURRENT Per ••- DUAL POWER 50URCE Per • - AC VCEC 690.54 • Point , Interconnection OPERATING VOLTAGE PHOTOVOLTAIC SYSTEM 3055 Cleaview Way San Mateo,CA 94402 T:(650)638-1028 F:(650)638-1029 SC CA Label Set • • im • I / SolarCity SleekMountT'" - Comp SolarCity SleekMountT'" - Comp The SolarCity SleekMount hardware solution • Utilizes Zep Solar hardware and UL 1703 listed i' 'V Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules aesthetics while minimizing roof disruption and • Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and • Interlock and grounding devices in system UL Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition listed to UL 2703 of array trim and a lower profile all contribute • Interlock and Ground Zep ETL listed to UL 1703 �' ® Seal pilot hole with roofing sealant as"Grounding and Bonding System" \ ® Insert Comp Mount flashing under upper to a more visually appealing system. SleekMount g g y utilizes Zep CompatibleT"' modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device • Place Comp Mount centered Zep Solar standoffs, effectively eliminating the need for rail and reducing the number of • Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition \ e Install lag pursuant to NDS Section 11.1.3 •Anodized components for corrosion resistance shingles are not required to be cut for this with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions ® Secure Leveling Foot to the Comp Mount " using machine Screw Place module Components B 5/16"Machine Screw ® Leveling Foot ` Lag Screw ® Comp Mount Comp Mount Flashing 0 0� D: 0 6, ® x �JPERTINO wilding Department �t,� ►� =�" - �' )E COMPLIANCE SolarCitV SOS �L LISTED 'SolarCity s, J� January 2013 �c�.�' y© January 2013 n E � =ee SolarEd a Power 0 tlmizer solar solarg P Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer Module Add-On For North America P300 7350 P400 (for 60-cell PV (for 72-cell PV (tor 96ce11 PV modules) modules) modules) P300 / P350 / P400 INPUT - — 1 P k 300 3 d Rated n ut DG owe 50 DO W P Absolute Maximum Input Voltage(oc at lowest temperature) 48 60 80 Vdc ...................._.... .. .. .8_ .. . ...Vdc.. . Maximum Short Circuit Current(Isc) 10 Adc Maximum DC Input Current 12.5 Adc Maximum Elfidency 99.5 % ................................. .. .. ..............-................... ............ .. .... .....................................................__.._..._.__....._........98:8...._......... % Overvoltage Category_ It OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO ERATING INVERTER) — Maximum Out ut Current ,.,.1S,.,._,,,„,,,,,,,,,,,,,,,,,,,,,,,,,,,,, ,,,Adc,,,_. 4 ................................................................................. _ Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer I I Vdc STANDARD COMPLIANCE — FCC Part15 EMC..... ........ Class 8,IEC63000-6-2,I...... 0-6.3. .._. . .......... Safety ....._...._.. ....... ......................._..........IEC62309-1(lass IIsafety),U1_1741 Ro Hs Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc .. ............................ .........._..................................._._.....____... ...................................... ._.....__. Dimensions(W xLx H) 141x212 x4O5/SSSx8.34x159 mm/in ................................................................................................................................................................ ............. weight(indudingables)............................_............__._..._.............._.........9so/z.1.._._............................. .. alb.... Input Co ecto MC4/Amphenol/Tym .- Output Nlre Type/Connector Double Insulated Amphenol - - . ... .. .. ...._. .. .. Output W're Length.. .. .....................0.95/30......1 ..1.2/3.9 m/ft . .... ... ....................... Operating Temperature Range ...... Protection Radng............... ..................................IP65�,NEMA4 _._.. Relative Hum....._................................................ ..................._..._.._........0..1 ............._...... % m rwa sic w-e d mr moaw,r°m�rd w m.sa w-e m`.rr<rno..a PV SYSTEM DESIGN USING A SOLAREDGE THREE PHASE �'' THREE PHASE INVERTER SINGLE PHASE 208V "OV PV power optimization at the module-level ...................... s i” 1a Up to 25%more energy Maximum String Length(Power Optimizers) 25 25 SO — Superior efficiency(99.5%) Maximum.Power pe._String..___..__.__ ........................5250,,,,,_,_... 6000_._.__.,.,,..,,...,,..12750,.,,,,. ..W...... Parallel strings of Different Lengths or Orientations ... ................ ..... Yes _..._....._...._. — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading `"' """ """."' ....." .... ............ ......... ...... _,__.._.__ - - Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for Installer and firefighter safety 0.' CUP'ERTINO USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us Building Department : ., Auu . : 2014 REVIEOJEl--)' �"UF CODE COMP JANCE Hevievred B ��? . SolarCity Advantage Module Electrical Parameters at Standard Test Conditions(STC) The SolarCity Advantage module represents a 60 Cell, ZEP enabled Power Output Pmax W 255 module.The values shown are the most extreme potential values Power Output Tolerances APmax W -0/+5 from SolarCity's portfolio of CEC approved and UL or ETL listed Module Efficiency nm % 15.85 modules. Modules will have a minimum 10 year warranty. The Maximum Power Voltage Vmp V 30.2 module installed will be one of the following: Maximum Power Current Impp A 8.43 Open-circuit voltage Voc V 37.7 Short-circuit current Isc A 9 Trina Solar: TSM255PA05.18 Canadian Solar: CS6P-255PX Values at Standard Test Conditions STC(Air Mass AM1S,Irradiance 1000W/m',Cell Temperature 25°C). Electrical Parameters at Nominal Operating Cell Temperature (NOCT) Power Output Pmax W 185 Voltage at Pmax Vmpp V 27.4 Current at Pmax Impp A 6.77 Open-circuit voltage Voc V 34.4 Short-circuit current Isc A 7.31 NOCT:Irradiance at 800W/m',Ambient Temperature 20°C,Wind Speed 1M/s. Thermal Characteristics Nominal operating cell temperature NOCT °C 46+/- 2 Temperature coefficient of Pmax y %/°C -0.43 Temperature coefficient of Voc RVoc %/°C -0.34 Temperature coefficient of Isc ctlsc %/°C 0.065 General Characteristics Solar Cells Multicrystaline Frame Aluminum alloy/anodized black Weight 45.2 lbs (20.5 kg) Sodding Department r� �4 TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE Mono Multi Solutions DIMENSIONS OF PV MODULE TSM-PA05.18 ELECTRICAL DATA Cal STC TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 941mm Peak Power Watts-P-(Wp) 240 245 250 255 260 Power Output Taleronce-P-1%) 0/+3 0/+3 0/+3 0/+3 0/+3 m Maximum Power Voltage-V.Nr(V) 29.7 30.2 30.3 30.5 30.7 eac o Maximum Power Current-IMvv(A) 8.10 8.13 8.27 8.36 8.47 TSM = PA05 .18 -��"TE f o Open Circuit Voltage-Voc IV) 373 37.5 37.6 37.7 37.9 +e a:u � wsT,u�+c r,a[ Short Circuit Current-Isc(A) 8.62 8.68 8.85 8.92 9.00 Module Efficiency rlm(%) 14.7 15.0 15.3 15.6 15.9 THE TRINAMOUNT MODULE STC:Irradiance 1000 w/m'.Cell Temperature 25°C,Air Mass AMI.5 according la EN 60904-3. E Average efficiency reduction of 4.5%at 200 W/m'accarding to EN 60904-I. E o 3 3 - 3 ELECTRICAL DATA @ NOCT TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 /� PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 CELL 60 ( ELL Maximum Power-P-(Wp) 174 178 181 184 188 Maximum Power Voltage-V_(V) 26.6 26.8 27.0 27.2 27.4 MULTICRYSTALLINE MODULE A A Maximum Power Current-Imrr(A) 6.55 6.64 6.70 6.77 6.86 WITH TRINAMOUNT FRAME " """"E Open Circuit Voltage(V)-Voc(V) 34.1 34.2 34.3 34.4 34.6 Short Circuit Current(A)-Isc(A) 7.04 7.10 7.25 7.31 7.37 240 26 0 W 812mm 180 NOCT Irradiance at 800 W/m',Ambient Temperature 20°C Wind Speed l m/s. Back View POWER OUTPUT RANGE Our most versitile .product MECHANICAL DATA Compatible with all major BOS components and system Solar cells Multicrystalline 156.156 mm(6 inches) designs Cell orientation 60 cells(6 x 10) 1 r 5• Module dimensions 1650.992.40 mm(64.95 x 39.05 x 1.57 inches) , Weight 18.6 kg(41.0 lbs) MAXIMUM EFFICIENCY Glass High transparency solarglass3.2Trim(0.13inches) One of the industry's most trusted modules Backsheet White - '.,�ii • Over 2 GW sold across all major global markets Frame Black Anodized Aluminium Allay with Trinamaunt Groove 1 Field proven performance I-V CURVES OF PV MODULE TSM-245 PA05.18 .1-Bax IP 65 or IP 67 rated IrV T �'}%�'� 0 /o Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), 10.61 1100 mm(43.3 inches) POWER OUTPUT GUARANTEE 9. poo &. Connector Original MC4 _7- 8ww/m' Highly reliable due to stringent quality control m d 5.- As o leoding global monufccfurer Over 30 in-house tests (UV,TC, HF,and many more) v a.- TEMPERATURE RATINGS MAXIMUM RATINGS of next generation coJtoic In-house testing goes well beyong certification requirements 3- ppw/m' Nominal Operating Cell 45°C(t2°C) Operational Temperature -40-+85°C products,we believe CloyIoSe 2.� Temperature(NOCT) Cooperation with our partners O Maximum System 1000VDC(IEC)/ Is Critical to success. With local a.0. 10°1 pm 30- 40m Temperature Coefficient of P_x -0.43%/•C Voltage 600V DC(UL) presence around the glove,Trina is Voltoge(v) Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A able to provide exceptional service Temperature Coefficient of Isc 0.047%/°C to Poch customer in each market and supplement our innovative, Certified to withstand challenging environmental reliable products with the packing conditions of Trino cs c strong,bonkoble 130 km/hr wind load (2400 Pa) WARRANTY R�� R I p �^ partner. we ore committed 900 kg snow load per module (5400 Pa) 10 year Product Workmanship Warranty `` I I Vp�° G to building strategic,mutually - beneficial collaboration with 25 year Linear Power warranty ( Building DecrBrtmert* nstcliefs.developers,distributors (Please refer to product warranty for details) gam- m and other parlrlers aS the AUGbackbone of our shored success in CERTIFICATION u 201 o driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY � ,, PACKAGING CONFIGURATION 10 Year Product Warranty • 25 Year Linear Power Warranty ^� cw Or cCHus Modules per 4ox:24pieces � 1'I��Y)=U r:GH LODE C M-PL E,c i'll Trina Solar Limited www.trinesolorca,n Modules per 40'container:672 pieces 3100% Adtltl)a M i_~ E ` 1° v - B ti - nal value frLam am Trina Solar s linear K air ' anty CAlJT10N,READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT Trinasolar 80% change without notice. Trinasolar02013TrinoSolar Limited.All rights reserved.Specifications included inthis dolosheelore subject to �•`°""'`F• O Smart Energy Together Smart Energy Together Yeors 5 10 15 20 25 �O' ■ Industrystandard ■ Trina Solar w`ey,Ed�ees,8� ` to CS6P-235/240/245/250/255PX �eakt�ropgh4Tam _r CanadianSolar Electrical Data Black-framed STC CS6P-235P CS6P-240P CS6P-245P CS6P-250P CSSP-2650X Temperature Characteristics Nominal Maximum Power Pmax 235W 240W 245W 25OW 255W _ Optimum Operating Voltage m 29.8V 29.9V 30.OV 30.1V 30.2V Pmax .0.43%/`C NewEdgOptimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Voc -0.34%/-C Open Circuit Voltage(Voc) 36.9V 37.OV 37.1V 37.2V 37AV Isc 10.065%/'C _ Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature 4532`C e Module Efficiency 14.61% 14.92% 15.23% 15.54% 15.85% Operating Temperature -40`C-+85'C Performance at Low Irradiance . 1 . 1 Maximum System voltage 1 OOOV IEC /600v UL Industry leading performance at low Irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification ClassA Irradlance of 1000w/m'to 200W/m' Power Tolerance 0-+5W (AM 1.5,25 C) Next Generation Solar Module Under Steed.rdTest Conditions(STC)olirradiance oflooOWlm'.spWrum Au 1.5 and call temperature of25C NewEdge,the next generation module designed for multiple Engineering Drawings NOCT S6P-235P CS6P-240P CS6P-245P CS6P-250PX CS6P•255PX types of mounting systems,offers customers the added Nominal Maximum Power Pmax 170W 174W 178W 181W 185W value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vm ) 27.2V 27.3V 27AV 27.5V 27.5V appearance,auto groundingand theft resistance. Optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage(Voc) 33.9V 34.OV 34.1v 34.2V 34.4V The black-framed CS6P-PX is a robust 60 cell solar module Short Circuit Current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A Incorporating the groundbreaking Zap compatible frame. Under Normal operating Cell Temperature,Irradiance of 800 Wlm',spectrum AM 1.5,emblent temperature 20C, The specially designed frame allows for rail-free fast wind speed 1 m/s installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6 x 10) with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.57in) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high weight 20.5kg(45.2 lbs) reduces installation time quality aesthetic module with lowest system cost. Front cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy • Lower system costs - can cut rooftopJ-BOX IP85,3 diodes installation costs in half Best Quality • 235 quality control points in module production Cable 4mm'(-4 or C-4 Comparable able • Aesthetic seamless appearance - low profile • EL screening to eliminate product defects connectors MC-4 or M24 Comparable with auto leveling and alignment • Current binning to improve system performance Standard Packaging(ModuhsperPCont zs(4 Module Pieces per container(40ft.Conteiner) 672pcs(40'HO) • Accredited Salt mist resistant • Built-in hyper-bonded grounding system - If it's I-V Curves (cs6P-255Px) mounted,it's grounded Best Warranty Insurance i • Theft resistant hardware • 25 years worldwide coverage • 100%warranty term coverage SecuonA-A i • Ultra-low parts count - 3 parts for the mounting • Providing third party bankruptcy rights 1 35.0 and grounding system • Non-cancellable coverage - • Industry first comprehensive warranty insurance by ImmediateI o i AM Best rated leading insurance companies in the Insured by 3 world top insurance companies } i world n. Comprehensive Certificates • Industryleading plus only power tolerance:0-5W 5W • IEC 61215,IEC 61730, IEC61701 ED2,UL1703, • Backward compatibility with all standard rooftop and CEC Listed,CE and MCSp 1r NO ground mounting systems • IS09001:2008:Quality Management System ! _y r[gyr� 1 `Speclflcations included in this datasheet am subject to than without prior notice. Buildirl • ISOlTS16949:2009:The automotive quality ) g° Q Department system s • Backed By Our New 10/25 Linear Power Warranty management y Plus our added 25 year insurance coverage • IS014001:2004:Standards for Environmental About Canadian Solar AUG' @� 2014 management system Canadian Solar Inc.Is one of the world's largest solar Canadian Solar was founded In Canada 0-1-'and was i� 1�� Added Val • QC080000 HSPM:The Certification for companies. As a leading vertically-Integrated successfully listed on NASDAQ] Exchangesymbol: CSIQ) In ue From Hazardous Substances Regulations manufacturer of Ingots,wafers,cells,solar modules and November 2006. Canadian Solar has m {f I� yrkil�.t GODE C�� sox Warranfy OHSAS18001:20071nternatfonelstandardsfor solar systems, Canadian Solar delivers solar power capacity oft.05CsWandcallmanufacturingcapacityofI.3 W. LANCE products of uncompromising quality to worldwide as occupational health and safety customers. Canadian Solar•s world class team of It s 10 1a 20 to REACH Compliance professionals works closely with our customers to ' provide them with solutions for all their solar needs. •10 year product warranty on materials and workmanship O ;F,AOX E• 0- s�r.e -C,,e..r • Tel �1 519 83 1 1881 25 year linear power output warranty �/ a-+ Fax 1 519 837 25�)D www.canadiansolar.com I3kew t..tiCa.gdpM e2Nj►� ::. 1 so I a r single Phase Inverters for North America solar=@ " . , • t� SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ SE1600A-US/SE10000A-US/SE11400A-US SE3000A-US SE380OA-US I SESOOOA-US I SE6000A•US I SE760OA-US I SE10000A-US I SE1140OA-US OUTPUT SolarEdge Single Phase Inverters Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA ........................................... ................ . 10000 @240.. ............................................... .............................. ............................. 5400 @ 208V 10800 @ 208V For North America Max.AC Power Output 3300 4150 6000 .—.. 12000 VA .......................................... . s450.�240.. 10950 @2aoV, AC Output Vokage Min:Nom,-Max.• V V SE3000A-US/SE3800A-US/ SE5000A-US/SE6000A-US/ 183-208-229 Vac ........................................ .............I.... ............................................................. ................ ........ AC Output Voltage Min.-Nom.-Max.• V V V V J J J SE760OA-US/SE1000OA-US/ SE1140OA-US211-zoo-264 Vat ........................................... ................ ................................................ .................................. ............................. AC Frequency Min.:Nom:Max.' ... ..... 59.3:60:60Swith( HI country setting 57.:60,;60 .5).............. .............. ..Hz.... .. .. q ,. ....... ...... ....... .. .. 24 @ 208V 48 @ 208V Max.Continuous Output Current 12.5 16 25 32 47S A GFDI . ......... 1 A Utility Monitoring,Islanding. .................................................................... ............... Protecdon,Country Configurable Yes _ —.. Thresholds INPUT Recommended Ma).DC Power" 3750 4750 6250 75009500 12400 14250 W Via ).................................... ................ ................................................ ............................................................... ' TlansformeMess U rounded Yes "a## Max.Input Vok500 Vdc .................... ...................... ..................................................................................................................................... - _� Nom:DC Input Voltage................. ............ 325 @ 208V/,350 @ 240V Vdc i Max.Input Current*** 95 L3 15 5 @ 208V 18 23 0 @ 24V 34.5 Adc Max.InQut Short Grcuk Currertt...... ...............................30,. 45 Adc iReverse Polarity Protection ..........................I................................Yes Ground-Fauk Isolation Detection 6001m5ensitivky ........................................... ................ ........i....................... Maximum Inverter Efficien 97.7 98.2 983 98.3 98 98 98 % ..............................n.......... ................ .........,...................................... .................................. .........I..............,.... 97.5 @ 208V 97 @ 209V 14 Weighted Efficiency 97S 98 % 240V 97.5 97.5 97 5 @ 240V 97S % " N httlmePowerConsum on <2S <4 W ADDITIONAL FEATURES Supported Cammunkatlon Interfaces R5485,RS232,Ethernet,AgRee(optional) ........................................... ..................................................................................................................................... Revenue Grade Data,ANSI C12.1 Optional STANDARD COMPLIANCE Safety. .......................................UL1741r UL1699B UL1998 r CSA 22 2 . ................................................. Grid Connection Stand ardsIEEE1547 ........................................... ........................................................................................................................ ......... ----- Emissions FCC partlS class 8 INSTALLATION SPECIFICATIONS iI AC output mnduk size/AWG range3/4'minimuT./.2 4 6 AWG 3/4'minimum/8-3 AWG j DC Input conduit We/8 of strings/ 3/4'minimum/1-2 strings/24-6 AWG 3/4'minimum/1-2 strings/14-6 AWG AWG ranRe ............................. .....................I........... - Dimensions with AC/DC Safety 30.5 x 12.5 X7/ 30.5 x 12.5 x 7.5/ in/ 30Sx3.2.5x10.5/77Sx315x260�. _ Switch 1H,") 775 x 315 x 172 775 x 315x191 +n} mm Weight with AC/DC Safety Switch51,2 /23.2................. ..54.7/24.7 .......... . 88.4/40.1 Ib/ .............. -- Iln Na ctlon Fens user re a ... ................................. .........................t9!�I.�O.^. ............................. ....................5.. m. p.,a ...... . 0 uildinq De rtrrtertt The best choice for SolarEd a enabled systems .... <25 <so ���<+; d8A V .... ........................... ................ .......... ................................... ..................I.............. �............. g 7 Min.-Max.Operating Temperature -13 to+140/-25to+60(CAN version*•••-40to+60) `, F - Integrated arc fault protection[Type 1)for NEC 2011690.11 compliance R?.ng?........... . i .:.:.... .JOU j 13 2014 Superior efficiency(9896) Protection Rati"6..................... NEMA 3R .......... �►cr ctler e�axlsutlno pkaae oaa.csdefdP copar_.. ................... .... ................. ..... Small 1 i ht and ea to install on provided bract et m �r�lr.me l+a� .e.e�.err/esc„,a m z3s%%r 1a k 1s bM..n•rns•c ightweg p E-V)EWEG rCUFt GLIDE COMPLIANCE Built-in module-level monitoring "'3A���^wbe�ft"�Wa�ft"VA�m"t� " ••••uNP/Pk ne.ataa•rM the 0Mft wrWA WAMW(M=Wn M14130 &C;N} Internet connection through Ethernet or Wireless Reviewed By — Outdoor and indoor installation — Fixed voltage inverter,DC/AC conversion only — Pre-assembled AC/DC Safety Switch for faster installation — Optional-revenue grade data,ANSI 012.1 • USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us