Loading...
14080256 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 20955 STEVENS CREEK BLVD CONTRACTOR:SOLARRUS CORP PERMIT NO: 14080256 OWNER'S NAME: WEISS PAUL E AND BARBARA H TRUSTEE 5406 BOLSA AVE DATE ISSUED:08/26/2014 OWNER'S PHONE: 4156225040 HUNTINGTON BEACH,CA 92649 PHONE NO:(415)307-1737 �<_ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL E] COMMERCIAL E] WHOLE FOODS- INSTALLATION OF EV CHARGING r� License Class C V Lia# r f�- �� STATION Contractor s rdy� CCS a_ Date V Z I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the erformance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$8000 I have and will maintain Worker's Compensation Insurance,as provided for by ection 3700 of the Labor Code,for the performance of the work for which thisAPN Number:32631022.00 Occupancy Type: ermit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMITE ORK IS NOT STARTED correct. 1 agree to comply with all city and county ordinances and stale laws relating WITHIN 18 DAYS OF P MIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FR M LAST CALLED INSP CTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the ��(� granting of this permit. Additionally,the applicant understands and will comply Issued by: Date: with all non-point source regulations per the Cupertino Municipal Code,Section 9.18 RE-ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed. if a roof is installed without first obtaining an inspection,1 agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(x)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Secti s 25505,25533,and 25534. 1���� Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent Date: permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date CONSTRUCTION PERMIT APPLICATION 10 COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 CUPERTINO (408)777-3228• FAX(408)777-3333•building(&cupertino.org \ ❑NEW CONSTRUCTION ❑ ADDITION [] ALTERATION/TI ❑ REVISION/DEFERRED ORIGINAL PERMIT# PROJECT ADDRESS APN#l-/ ) W 1 X31 022 OWNER NAME PHONE E-MAIL lcJ STREET ADDRES� S�- CITY, TATE,ZIP FAX 77055 CONTACT NAME ( �L- /� PHONEE-M�p/ILd( ,{ STREETADDRESS ®� CITY,STATE. ZIP FAX ❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NU BER L .ENSE TYPE BUS.LIC? •tit Z COMPANY NAME so a CAP E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE ARCHITECT,ENGINEER NAME LICENSE NUMBER BUS,LIC COMPANY NAME F-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE DESCRIPTION OF WORK 7 i EXISTING USE PROPOSED USE CONSTR.TYPE 1 #STORIES USE TYPE OCC. SQ,FT. VALUATION($) EXISTG NEW FLOOR DEMO TOTAL AREA .AREA .AREA NET.AREA BATHROOM KITCHEN OTHER REMODF.LAREA REMODELAREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECK PORCH AREA GARAGE AREA: DETACH [-]ATTACH #DWELLING UNITS. ISA SECOND UNIT OYES SECOND STORY OYES BEING ADDED? ONO ADDITION? ❑NO PRE-APPLICATION ❑YES IF YES,PROVIDE COPY OF IS THE BLDG AN ❑YES RECEIVED BY: TOTAL LUTION: PLANNING ADPL# ❑NO PLANNING APPROVAL LETTER EICHLER HOME? ❑NO t! By my signature below,I certify to each of the following: [am the property owner or authorized ag t to act on t operty owner's behalf. I have read this application and the information I have provided is correct. 1 have read the Description of Work and verify It Is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. 1 authorize representatives of Cupertino to enter the above ied roperty for ins ection purposes. Signature of Applicant/Agent: Date: f 'L7 SUPPLEMENTAL INFORMATION REQUIRED PLAN CHECK TYPE ROUTING SLIP New SFD or Multifamily dwellings: Apply for demolition permit for ❑ OVER-THE-COUNTER ❑ BUILDING PLAN REVIEW existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS ❑ PLANNING PLAN REVIEW Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD ❑ PUBLIC WORKS form if any Hazardous Materials are being used as part of this project. ❑ LARGE ❑ FIRE DEPT Copy of Planning Approval Letter or Meeting with Planning prior to ❑ MAJOR ❑ SANITARY SEWER DISTRICT submittal of Building Permit application. ❑ ENVIRONMENTAL HEALTH BldgApp_2OI Woc revised 06/21/11 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 20955 scb DATE: 08/26/2014 REVIEWED BY: Mendez APN: BP#: J "r 'VALUATION: 1$8,000 PERMIT TYPE: Building Permit PLAN CHECK TYPE: Tenant Improvement PRIMARY Commercial Building PENTANIATION SOLAR-COMM USE: PERMIT TYPE: WORK whole foods- installation of ev charging station SCOPE E17-- Lj NOTE: This estimate does not include fees due to other Departments(i.e.Planning,Public Works, Fire,Sanitary Sewer District,School District,etc. . Thesefees are based on the prelimina information available and are only an estimate. Contact the De t or addn'l info, FEE ITEMS (Fee Resolution 11-053 Ef 7/1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 # Alternative Energy System Suppl. PC Fee: 0 Reg. 0 OT FO.0 Thrs $0.00 $109.00 ICHRGSTA EV Charging Station PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Feed Reg. C) OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 0 Work Without Permit? 0 Yes 0 No $0.00 E) Advanced Planning Fee: $0.00 Select a Non-Residential Q Building or Structure Strom Motion Fee: IRSEISMICO $2.24 Select an Administrative Item Bldg Stds Commission Fee: IRCRSC $1.00 SUBTOTALS: $3.24 $109.00 TOTAL FEE: 1 $112.24 Revised: 07/10/2014 _ PROJECT SITE iz _ gF' . WHOLE FOODS CUPERTINO ` i8 errri� �v_tri t' 20 955 STEVENS CREEK BOULEVARD Hig*r Sf .olid v; t liar `� i Cupertino `1 CUPERTINO, CA 95014 ring f LZ , shrt � PROJECT DEVELOPER • i= yy ,. u ., ..,. ,.,... ... .�.,..>� ..- .-....a.—, .,.,u..�.�>. r>.�... .. f .. m , I unt a, , _jI 111111111 11111111111 111111 1 16i, .11111111111 lie i Ll ,s 1«+•v`. l S.'. a 5 111.9 _ r,S 1 t � {, i m� �e g��a �b le Ch4.E''c_�i +*� +ry`#_E. i; { ! 6.. rtoo, I 0SM ;. 12231 KATY FREEWAY EVGO 69 ,t HOUSTON, TX 77079 H ti 'r = r � ,r: tY�4.*r �1 �! ��, r' z; - = � _ � � �:r �Illlllllllllllillillllllilllllll° TEL: (855) 509-5581 7. .�3 a � 4 f Sj , i 1"a- fes_" 4t; 1 ,i', ice` � =� _ �• ��,litrifi�vt� t: � ,i.wr,it,==:,:it -� � DESIGN BUILD FIRM - �, � ! q.n Cupertino #J�i 113>�7i �1" �tt'j- tl-* J t - IIlIIIIIIIIIIIIIIIIIIIIIlIIIIIII� 4_115'? 'r{.r7 [t a7, O'e ,r.'r�iva Park-rk- �-=t _ Pa s t l,-t r� L '! St Joseph of �� � �~ 1-����i - # (.a _ a — ax f L( rrt rl r�ra��ly fief G `'« _ penin I'lawts' r� - y a _ �. elf*,1�1 . R C iters 41 SOLARR .fit y fir* rr °i 406 BOLSA AVENUEN { i:+: r• h's� Blvd �"�ie'i1 'i�4� l fi aie , ice#} �r �� I.�+r-tt`k d�1'4',i� ( ¢¢t- t• yt tt - RATIO 5 HUNTINGTON BEACH, CA 92649 Ck Pert n rj Cupertino p¢� TEL: (949) 333-0899 t£�t k:fe. 'fa �'1��' ,';�_ Et,%-,pf�.`'-til. .a..- - !!`stras rri�tad .--a-,. '.f C"- as �'���1-setim f ,art � g Ce Pari r�tr * CA LICENSE #: 942587 ss r' _ CONTRACTOR _ I �pyy - rX >> ,#t - �'1 Rr j 77, - y Cupertino "xJ � t�'1' 1' #'1� t <,g ��'z�'-�CEI i I p AUG 2 6 2014 x=hrl:.r I - - .: ._., � �� yra ° 6=x 11�`l��'���i' i v—: ,.3 t,'.P't`,s�.+i��i'C f f��i4;S ... ® �.''S}�(`��j �I`,• ..._ —' i. � S 1'1 ... - � �•-s �! 1 r a _ f t - xai•rar +�i S i . ++ New ' Ir Kin g do 7Th Hall �„j,_. , � � s L t r _ m # tiF t l” .�� t r�12-l�n� Ly t , htF f.,r9 •s+'.,' - 5�3. r fw. It Q) E I S f VICINITY MAP _p SITE MAP j, SCALE NTS ? SCALE: NTS ICE COPY -.... .c- __c.-_src__u�¢aw.:s✓.v.-.:eam:.�nz.en+.n.+,.t..=>e.... u.x.....v.—,.a>._�—.,r-._ _..�scmn -.+ _._ .� _ Tj 1 I t SCOPE OF WORK: LEGAL DESCRIPTION DRAWING INDEX REVISION _ MARK DATE DESCRIPTION ® INSTALLATION AND WIRING OF A 50kVA ELECTRICAL VEHICLE CHARGER APN # : G-0.0 TITLE SHEET ` _ „ Q _ • BUILDING/STRUCTURAL: PERMIT # 14020116 PARCEL MAP # : G-0. 1 GENERAL NOTES, LAYOUT, ELEVATION LOT # : E-2.0 ELECTRICAL . j _ PARCEL # : 3 SHEETS TOTAL - i t ) i APPLICABLE CODES i I 4 201. 1 NATIONAL ELECTRICAL CODE _ 201.3 CALIFORNIA ELECTRICAL CODE CUPERTINO — 201.3 CALIFORNIA BUILDING CODE Building Department COMMUNITY DE`JELOPMENT DEPARTMENT 3, DRAW BY: 71-- 201.3 CALFIORNIA GREEN BUILDING CODE BUILDINv DlvlsloN - CUPERTINo _`-" ti — AUG 2 j'i 2014 CHECKED BY: R" APPROVED I'EVIE0,ED �C7R CODE COMPLIANCE SCALE: AS SHOWi� 201.3 CALIFORNIA MECHANICAL CODE n — This set of plans and specifications [41UST be kept at the j $/21/14 jeb site during construction. It is unlawful to make any ileviewed By. ��;�; ��� � DATE: _ 201.3 CALIFORNIA PLUMBING CODE changes or alterations on same, or to deviate therefrom,without approval from the Building Official. _ eVg The Stamping of this p nand specifications SHALL NOT i SHEET TITLE be held to permit o an approval of the violation 1 of any provisions a City Ordinance or State Law. WHOLE FOODS - CUPERTINO I BY EVGO DATE PERMIT# TITLE SHEET WHOU MDS� U-T F171 1 SHEET NUMBER - I: G-0 . PROJECT SITE _ GENERAL NOTES SYMBOLS LIST 1. PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO ACHIEVE A COMPLETE AND OPERATING SYSTEM. (N) ABB LEVEL 3 EV CHARGER 2. COORDINATE AND OBTAIN APPROVALS FROM ALL RESPECTIVE UTILINAME COMPANIES AS REQUIRED FOR ANNOTATIONS A COMPLETE AND OPERATING INSTALLATION. (E) EQUIPMENT PAD 3. INSTALL RACEWAY SYSTEMS AS FOLLOWS: O LIGHTING FIXTURE DESIGNATION.REFER TO LIGHTING FIXTURE SCHEDULE. a.USE RIGID GALVANIZED STEEL IN ALL AREAS EXPOSED TO WEATHER OR PHYSICAL DAMAGE. 0 I b. USE FLEXIBLE METALLIC CONDUIT ONLY IN AREAS AS PERMITTED BY LOCAL CODE AUTHORINAME. DETAIL REFERENCE - ' --v N - � - s9�:.er�.. _ �� .�.���_��uN�=.��. �__��. ...�-..� �.. .�,p..�.a..z� ,����. _�. �r...�m�s,=.��., ,��_.,a..��_..w .__.P__�,..,. WHOLE FOODS - CUPERTINO I USE SEAL-TITE IN AREAS EXPOSED TO WEATHER. 20955 STEVENS CREEK BOULEVARD c.USE P.V.C.CONDUIT UNDERGROUND WITH CODE SIZED GROUND.CONDUIT RISERS AND STUBS 1 SHEET NOTE REFERENCE ABOVE GRADE SHALL BE INTERMEDIATE METAL CONDUIT WITH HALF-LAPPED TAPE COVERING OR P.V.C. CUPERTINO, CA 95014 COATING. O i d.THE USE OF ROMEX OR BX IS NOT PERMITTED. 1 DETAIL NOTE REFERENCE PROJECT DEVELOPER 4. ALL NEW WIRING SHALL BE COPPER NAMEPE'THHNITHWN-2"-U.O.N.. 5. THESE DRAWINGS ARE DIAGRAMMATIC AND REPRESENT THE INTENT OF EQUIPMENT,DEVICES,ETC...TO EF MECHANICAL EQUIPMENT CALLOUT. "EF"INDICATES UNIT TYPE AND"1" BE CONNECTED AND THE CIRCUITS TO WHICH THEY ARE TO BE CONNECTED TO.CONTRACTOR SHALL INDICATES UNIT NUMBER.REFER TO MECHANICAL DRAWINGS FOR EXACT IINSTALL ALL CONDUIT,J-BOXES,ETC...AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. LOCATION AND ELECTRICAL REQUIREMENTS. - 6. ALL EXTERIOR EQUIPMENT SHALL BE WEATHERPROOF. < FDR# FEEDER CALLOUT I 7. ELECTRICAL CONTRACTOR SHALL PERFORM ALL WORK IN STRICT ACCORDANCE WITH ALL LOCAL AND STATE / J ! NATIONAL GOVERNING CODES. 7Q REVISION REFERENCE ! eVgo,M 8. ALL EQUIPMENT SHALL BE NEW AND"UL"LISTED-U.O.N.. POWER 9. COMPLETE ELECTRICAL INSTALLATION SHALL BE GUARANTEED IN WRITING FOR A PERIOD OF(1) EVGO 12231 KATY FREEWAY YEAR-u.aN.. � � HOUSTON TX 77079 DISCONNECT SWITCH.AMPS-VOLTS&POLES AND FUSED OR NON-FUSED '`� 10. ELECTRICAL CONTRACTOR SHALL VISIT SITE PRIOR TO BID DATE,TO VERIFY ALL EXISTING CONDITIONS AS INDICATED. } ...... j TO BE ENCOUNTERED IN THE INSTALLATION OF ALL NEW EQUIPMENT, FIXTURES DEVICES,FEEDERS, TEL: (855) 509-5581 COMBINATION STARTER DISCONNECT SWITCH.AMPS-VOLTS&POLES I ETC.. EXACT INSTALLATION METHOD AND REQUIREMENTS SHALL BE VERIFIED AND DETERMINED PRIOR TO f f i s _ AS INDICATED. i I , �` �� � , BID DATE.CONTRACTORS SHALL IMMEDIATELY NOTIFY THIS ENGINEER OF ANY REQUIRED MODIFICATIONS / x f. , f f ! ! DESIGN BUILD FIRM ! WHICH ARE NOT SHOWN ON THESE DRAWINGS.SUBMITTAL OF BID INDICATES CONTRACTOR IS - JUNCTION BOX.SIZED BY THIS CONTRACTOR PER ACTUAL NUMBER OF CONDUITS I f ' -- f COGNIZANT OF ALL JOB SITE CONDITIONS AND WORK TO BE PERFORMED. O 'r r -- --� AND/OR CONDUCTORS PASSING THRU ACCORDING TO NEC 2005 TABLE 314-16(a)(b). � ; r 11. ALL EQUIPMENT ELECTRICAL CHARACTERISTICS,NEMA CONFIGURATION, LOCATIONS,AND CONNECTION REQUIREMENTS SHALL BE VERIFIED PRIOR TO ANY ROUGH-IN WORK. JUNCTION BOX,WALL MOUNTED AT+18"A.F.F.FOR FLEXIBLE CONNECTION TO PRE- J ff r r �O WIRED FURNITURE SYSTEM.VERIFY CONNECTION REQUIREMENTS AND LOCATIONS WITH 12. COMPLETE ELECTRICAL SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH THE PRESENTLY ADOPTED FURNITURE MANUFACTURER PRIOR TO ROUGH-IN. EDITION OF THE C.E.C.ART.250. 13. PROVIDE THE OWNER WITH ONE SET OF ELECTRICAL"AS-BUILTS"AT THE COMPLETION n CIRCUIT BREAKER(SEE SINGLE LINE DIAGRAM) OF JOB. o FUSED SWITCH SEE SINGLE LINE DIAGRAM 14. THE EXISTING CONDITIONS SHOWN ARE FROM AVAILABLE RECORD DRAWINGS AND SHOWN ( ) FOR REFERENCE ONLY.CONTRACTOR SHALL VERIFY ACTUAL EXISTING CONDITIONS AT SITE J u r'' .✓ a i PRIOR TO SUBMITTING BID.ALL DEMOLITION,ALTERATION,EXTENSION,RELOCATION, -;;Z y TRANSFORMER(SEE SINGLE LINE DIAGRAM) - REHABILITATION WORK SHALL BE INCLUDED IN CONTRACT.NO ADDITIONAL ALLOWANCE OR CHANGE ORDERS WILL BE ACCEPTED. ' ? _ ( � ' �, j J S N a n ,� _ �' f OLARRUS CORPORATION ' 5406 BOLSA AVENUE 15. VERIFY ALL DISCONNECT SWITCHES,FUSE SIZES AND NAMEPES WITH MECHANICAL EQUIPMENT _ BRANCH CIRCUIT PANELBOARD.FLUSH OR SURFACE MOUNTED AS INDICATED MANUFACTURER PRIOR TO INSTALLATION. ON PANELBOARD SCHEDULE. HUN CH, CA 649 TINGTON BEA 92 TEL: (949) 333-0899 16. A SEPARATE GROUNDING CONDUCTOR SHALL BE RUN IN ALL NON METALLIC CONDUIT RUNS. ® SERVICE ENTRANCE OR DISTRIBUTION EQUIPMENT AS SPECIFIED. 17. ALL-ELECTRICAL DEVICES SHOWN IN LIGHT ARE EXISTING TO REMAIN AND DARK ARE NEW. CA LICENSE #: 942587 DATA , �� _ � �_ .a ; �r � �� �� , . fi �r � �.� _.. - — t y ' t %' CONTRACTOR ABBREVIATIONS , f rX-J" — Q DATA OUTLET AT+18"A.F.F., U.O.N.-PROVIDE 1"CONDUIT �� STUB-UP 6"MINIMUM INTO ACCESSIBLE CEILING SPACE. ! AMPERES KW KILOWATTS j f� I AMPERE INTERRUPTION CURRENT KWH KILOWATT-HOURS i COMBINATION TELEPHONE/DATA OUTLET MOUNTED WITHIN FLUSH OR SURFACE OUTLET BOX ALUMINUM LCL LONG CONTINUOUS LOAD I AMPERE SWITCH LF LINEAR FEET "P'DENOTES FLUSH AND"S"DENOTES SURFACE r Li AMPERE TRIP LPS LOW PRESSURE SODIUM AMERICAN WIRE GUAGE LTG LIGHTING --T — SYSTEM CONDUIT 3/4"C.O. E BARE COPPER LTS LIGHTS 1 BREAKER MAX MAXIMUM --T1 — SYSTEM CONDUIT 1"C.O. CONDUIT MCB MAIN CIRCUIT BREAKER I CIRCUIT BREAKER MIN MINIMUM --T2— SYSTEM CONDUIT 1 1 4"C.O. CLOSED CIRCUIT TELEVISION MLO MAIN LUG ONLY / CIRCUIT MOCP MAX OVERCURRENT CONDUIT ONLY PROTECTION --T3— SYSTEM CONDUIT 1 1/2"C.O. COPPER MTD MOUNTED DETAIL MSB MAIN SWITCHBOARD DISCONNECT(.SWITCH) MSG MAIN SWITCHGEAR Y_ DIRAWMNG ON PANEL N NEUTRAL BRANCH R /� N C H CIRCU ( T � EV CHARGING� STATION LA1 ®UT _ DETAIL' NC NO CONDUIT J� 3 NEC NATIONAL ELECTRICAL CODE a ELECTRICAL CONTRACTOR 4 EQUIPMENT GROUND(GREEN) NIC NOT IN CONTRACT DENOTES#12 THHN/THWN-2 EQUIPMENT SCALE: 3/8" = 1'-0" EMERGENCY NL NIGHT LIGHT GROUND WIRE U.O.N. I NTS NOT TO SCALE CONDUIT CONCEALED WITHIN BUILDING WALLS OR CEILING SPACE. { ELECTRICAL METALLIC TUBING ?'DENOTES#12 THHN/THWN-2 ISOLATED EMERGENCY POWER OFF (N) NEW t' GROUND WIRE U.O.N. EXISTING OH OVERHEAD —-ff j 7 7— CONDUIT ROUTED BELOW FINISHED GRADE AND(OR CONCRETE SLAB. FULL LOAD AMPERES P POLE INCLUDE CODE SIZED COPPER BOND CONDUCTOR(NOT SHOWN ON PLAN) ALL HOMERUNS AND BRANCH CIRCUITS FIELD TO VERIFY PH PHASE IN ALL NON-METALLIC CONDUIT RUNS. SHALL HAVE GROUND WIRE-U.O.N.. FUTURE PA PUBLIC ADDRESS GROUND PDU POWER DISTRIBUTION UNIT ��' HOMERUN TO DESTINATION AS INDICATED.REFER TO CONDUIT SYMBOL ABOVE. CROSS LINE DENOTES GENERAL CONTRACTOR PNL PANEL OR PANELBOARD QUANTINAME OF#12 THHN/THWN-2 GROUND FAULT INTERRUPTER PVC POLYVINYL CHLORIDE INDICATES CONDUIT DROP WITHIN BUILDING WALL.REFER TO CONDUIT CONDUCTORS-U.O.N.. HERTZ (R) REMOVE SYMBOL ABOVE. 11-911 (N) ABB LEVEL 3 EV CHARGER NO CROSS LINE DENOTES � ISOLATED GROUND REC RECEPTACLE 2#12&1#12G THHN/THWN-2 INTERRUPTING SHORT CIRCUIT RECEPT RECEPTACLE INDICATES CONDUIT RISER WITHIN BUILDING WALL REFER TO CONDUIT JUNCTION BOX. (RL) RELOCATED —� SYMBOL ABOVE. CONDUCTORS-U.O.N.. RMS ROOT MEAN THOUSAND CIRCULAR MILLS CONDUIT SHALL BE 3/4"MIN.-U.O.N.. — -- ji - — SPECS SPECIFICATIONS t t SW SWITCH O KILOVOLT-AMPERES SWBD SWITCHBOARD SYM SYMMETRICAL — T,TELE TELEPHONE THHN THERMOPLASTIC HIGH ( I HEAT-RESISTANT NYLON-COATED ! i � - THWN THERMOPLASTIC I f �____� �_� REVISION HEAT AND WATER - NAMEP NAME ANT NYLON COATED - MARK DATE DESCRIPTION AL UG UNDERGROUND UGPS UNDERGROUND PULL SECTION r i U.O.N. UNLESS OTHERWISE NOTED V VOLT VA VOLT-AMPERES O VL VERIFY LOCATION M ` ' I W WATTS �\ _ WP WEATHERPROOF t� l XFMR TRANSFORMER j I L- (E) EQUIPMENT '(t - f 4 -- PAD f I 1 I DRAW BY: JF s 4 i t 3 CHECKED BY: RW IF � ��---- - ---- - --� --_- ----- ,�------------�-- � SCALE: A j�T S SHOWN Q 4 � r E DATE: 8/21/14 a � w �-� ` UPER110 SHEET TITLE 4^ y Building Depatment 4 - . �> WHOLE FOODS - CUPERTINO — -- -- ._mm__ ------- -- =-- — ----- ---------- -- -- —= __ AUG 2 ° 014 EV REVIEWED FOR CGDE COMPLIANCE � GO Reviewed By. /�� GENERAL NOTES, LAYOUT, ELEVATION f - _.����_ W----__ SHEET NUMBER WH&.E EVGO STATION EQUIPMENT ENT ELEVATION DETAIL: - Q A G— 1 SCALE. NTS ..� ..� ■ PROJECT SITE r� r � 4 _ i r - i4) 3/ T0 HWN'-2 1 1, { - i i - i fWDS L0C ;IED INSIDE OF E1_EC TIRI.C,\E P,0 C M WHOLE FOODS - CUPERTINO { , 3i z` iI-i ;" C$`=u' c> 4`.1`.z - 277/480V 'c '°F1 �; F L 1111Inquiry lea. N/A AL 1111Inquiry Na. lvr I 20955 STEVENS CREEK BOULEVARD CUPERTINO, CA 95014 ' ' ' '' ` _tJ ri 3 ' r i C �`` reject NRG-2xT53C or T53CJ Project NRG -2xT53C or T53CJ IP F — NIP IP __ f4 4 3 - � Doc. T e Technical Proposal Doc.Type Technics} Proposal PROJECT DEVELOPER BB Ref. EVCI-1401-tc0 ABB Ref. EVCI-1401-tcO - { �� sCt,' 20/240\/ d� !'. l ? 1, 200 , v� C,�: C, 277/4800 3U ��"A/ BUS Date January 3,2014 Date January 3, 2014 �, I I ! 1 EXECUTIVE SUMMARY 2.4 Enclosure \ 1 0A 80,x, 100A ` -r1A J 150A2 f 1 �P f 3)P � � This technical proposal is for two (2) ABB Terra 53C and/or (2) Terra 53CJ Direct Current The Terra 53 are housed in a Type 3R painted enclosure with corrosion-resistant base metal: 1 2- 1 / I,hIC 1 / (DC) Fast Chargers. Using the new international Level 3 charging standard CCS (Combined System Weight: 770 lbs(310 kg) 0SM eVg i �� ; u I Charging System, "Combo") connector, ABB's Terra 53C is a 50kW DC Fast Charger 4r 4 A W �U �0 Ua-P _N T capable of charging the new BMW i3 or Chevy Spark EV in less than 20 minutes. The Terra Dimensions: 21 W x 30 D x 75 inch H(525 x 760 x 1900 mm) OND PER NEC 250-102 �) 53 CJ also includes a connector utilizing the CHAdeMO 1.0 connector and protocol This standard is used for vehicles like the Nissan LEAF. In the case of a dual-standard charger, • Std.Cable Length: 10 ft(3.0 m) EVGO the connectors charge in series,meaning that only one vehicle can charge at any given time. Enclosure door should only be opened with main disconnect open. Only trained personnel 12231 KATY FREEWAY -- 10' G IR ,4 �_�H 1 -=