Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
14090206
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10788 JUNIPER CT CONTRACTOR:SKY POWER SYSTEMS PERMIT NO: 14090206 OWNER'S NAME: MR&MRS VOHRA 3130 CROW CANYON RD STE F DATE ISSUED:09/30/2014 OWNER'S PHONE: 4084766723 SAN RAMON,CA 94583 PHONE NO:(925)231-0472 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL COMMERCIAL r,. INSTALLATION OF ROOF MOUNTED SOLAR(20 License Class Lie,# d� K MODULES) Contractor S�� h SD f" Date (6.54 KW) I hereby affirm that 1 am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the formance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$33000 Wave and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:34257005.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. 1 agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the �j �� granting of this permit. Additionally,the applicant understands and will comply Issued by: ./ G� Date: 7 with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. RE-ROOFS: All Signature Date �! y All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner or the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(See.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous 1 have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should 1 use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 550 25 3,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this30�� permit is issued. Owner or authorized agent: f Date: 1 certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec,3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address _ I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Date /L)4�)qz�) 96� CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 (408)777-3228• FAX�8)733•buildin cupertino.org CUPERTIN�❑NEW CONSTRUCTION ❑ ADDITION /� ON/TI ❑ REVISION/DEFERRED ORIGINAL PERMIT# PROJECT ADDRESS ` Y j `4 / i1,,'' n^ t,,,`) APN#-+✓, .7 OWNER NAME t +1 LGr� 7��o ,/1 VI�i,PHON'F,j��� _ ^�F�7% E-MAIL STREET ADDRESSi�r 7 Ypr II'n 1+ CITY, STAT , (, Gl ( ��V I FAX CONTACT NAME l b�Z V 0� � PHONE �""�Iq_ z E-MAIL �2 STRF.F, DDRESS ^� n CITY�.$,TATE, ZIP �1 FAX (i o C„i.��le1'YL ❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME �n/ jjj LIC EN LICENSE Ty BUS.LIC# COMPANY NAME 5k 1�/� 5- 1) /n ✓ E-MAIL /t�j./�,.y /' FAX STR ET 0 RE�uw n llkl �r�� Cn,STATE,Z/I L1L/ V G�r2 +'.; 3 P OI�� ARCHITECT/ENGINEER NRME LICENSE NUMBER IlY/ s BUS.LIC COMPANY NAME E-MAIL FAX STREET ADDRESS �1 J; CITY,STATE,ZIP PHONE DESCRIPTION OF WORK I VA /1 EXISTING USE PROPOSED USE CONSTR.TYPE #STORIES USE TYPE OCC. SQ.FT. VALUATION($) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODFL AREA PORCH AREA DF,CK AREA TOTAL DECK/PORCH AREA=GARAGEDETACH ❑ATTACH #DWELLING UNITS: 1S A SECOND UNIT []YES SECOND STORY ❑YES BEING ADDED? []NO ADDITION? []NO PRE-APPLICATION ❑YES IF YES,PROVIDE COPY OF IS THE BLDG AN ❑YES R11CBI1rL1I TOTAL VALUATION: PLANNING APPL d ❑NO PLANNING APPROVAL LEITER EICHLER HOME. ❑NO By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all ppticable local ordinances and state laws relating to buingcopstructiijIi. I authorize representatives of Cupertino to enter the above-iddtif d roperty �in p ction purposes. Signature of AppIicant/Agent: 1 �'""" Date: SUPPLEMENTAL 114FOR7ATION REQUIRED tLvcxc tiUt} iG P _New SFD or Multifamily dwellings: Apply for demolition permit for i fiH EtuN T2 #VRDINIrOLANnvm_ w existing building(s). Demolition permit is required prior to issuance of building permit for new building. Q [p>i 5 ,,P'La�aNG PILA ,RgVM _Commercial Bldgs: Provide a completed Hazardous Materials Disclosure - TANR4RI ;x!1JB14 :VItaRiK; form if any Hazardous Materials are being used as part of this project. Copy of Planning Approval Letter or Meeting with Planning prior to submittal of Building Permit application. 11CMR + ETAEwRp11it � l�t�iw�t�tll�l�rrnit�t�:x;�i BldgApp_201 1.doc revised 06121111 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 10788 JUNIPER CT DATE: 09/30/2014 REVIEWED BY: SEAN APN: BP#: -VALUATION: 1$33,000 "PERMIT TYPE: Building PermitPLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION USE: PERMIT TYPE: SOLAR-RES WORK INSTALLATION OF ROOF MOUNTED SOLAR 20 MODULES 6.54 KW SCOPE E3_L_ NOTE: This estimate does not include fees due to other Departments(i.e. Planning,Public Works, Fire,Sanitary Sewer District,School District, etc. . These ees are based on the prelimina information available and are only an estimate. Contact the Detor addn'l info. FEE ITEMS (FeeRunt - E .' _"173 FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = # Alternative Energy System Suppl. PC Fee: Q Reg. ® OT 0.0 hrs $0.00 $236.00 1PHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:Q Reg. Q OT O p hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Work Without Permit? ® Yes (j) leo $0.00 � Advanced Planning Fee: $0.00 Select a Non-Residential 0 Building or Structure i Strom Motion Fee: IBSEISMICR $4.29 Select an Administrative Item Bldg Stds Cotnnlission Fee: 1BCBSC $2.00 SUBTOTALS: $6.29 $236.00 TOTAL FEE: 1 $242.29 Revised: 07/1012014 F1 I SMOKE I CARBON MONOXIDE ALARMS ` OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION CUPERTINO 10300 TORRE AVENUE• CUPERTINO, CA 95014-3255 (408)777-3228•FAX(408)777-3333•buiiding(aDcupertino.org n! Permit Noj* Address /0 :,._ A)/�� Gf' #of Alarms Smoke: Carbon Monoxide: PERMIT CANNOT BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE k �HAS BEENWNA)`TD R TF iTRNrD TO TAE BUILDING DIVISION - PURPOSE This affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314,2013 CBC Sections 420.6 ani 907.2.11.2 where no interior access for inspections are required. L CU Y CCt Y 61'''t 01cNW A 4,y rvi ' GENERAL INFORMATION 0 0�� d lI'S 12 t 2 ct u �_� r 113 Existing single-family and multi-family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the X X bedroom(s) On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel-burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space.Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2.An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above-referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. I have read and agree to com I th the terms and conditions of this statement e (,oar/Ojw}n,er Agent's)Name, 2 A ,� v� Z V()kfa, Signature.............. ......V...`.-...............................I............................Date: Contractor Name: Signature...................................................................Lic.#......................................Date: ................... Smoke and CO form.doc revised 03;18114 e u Renew=able Technology WEEB Washer, Electrical Equipment Bond The WEEB line of products is designed to bond solar PV modules to mounting structures and create an electrical path to ground. WEEBs eliminate the need for older, more costly grounding methods and greatly reduce the amount of labor and materials used in installations.The innovative WEEB design removes the need to run ground wire to each individual module and eliminates the need for surface preparation on anodized aluminum components. To install, WEEBs are placed between PV modules and mounting rails at clamping points or at bolted connections. When anti-seize is applied and the hardware is tightened down to the appropriate torque spec, the WEEBs' specialized teeth embed into anodized aluminum, galvanized steel, or any electrically conductive metal to establish a gas tight electrical connection. 19 Ml*_911111111&� FPO Aw AW-1.1 q • Material: 304 stainless steel • Listed to ANSI-UL 467 by Intertek ETL for use in Canada and the USA • Maximum electrical equipment ground conductor size when used with 2 WEEBs contacting each module in an assembly: 6AWG • Outdoor rated Solar Module Frame , i Solar Module Frame pis r i j . .;:.,.- WEEB 9.5 A ��'' � Mounting Rail Mounting Rail . Contact us at: 845.247.4708 www.we-lic.com U N I RAC SOLARMOUNT Technical Datasheets ' SOLARMOUNT Beams Part No, 3101320. 310132C-B, 3101680, 310168C-B, 310168D 3102080, 310208C-B, 3102400, 31024OC-0, 310240D, 410144M, 410168M,410204M, 410240M Properties Units SOLARMOUNT SOLARMOUNT HD Beam Height in 2.5 3.0 Approximate Weight(per linear ft) plf 0.811 1.271 Total Cross Sectional Area in2 0.676 1.059 Section Modulus(X-Axis) in 3 0.353 0.898 Section Modulus(Y-Axis) in 3 0.113 0.221 Moment of Inertia(X-Axis) in 4 0.464 1.450 Moment of Inertia(Y-Axis) in 4 0.044 0.267 Radius of Gyration(X-Axis) in 0.289 1.170 Radius of Gyration(Y-Axis) in 0.254 0.502 *Rails are extruded using these aluminum alloys: 600S-TS, 610S-TS, 6061-T6 NIENNEEMENNIMENIMMENEM SLOT FOR T-BOLT OR SLOT FOR T-BOLT OR 1.728 V4"HEX HEAD SCREW V4"HEX HEAD SCREW 2X SLOT FOR SLOT FOR BOTTOM CLIP 2.500 BOTTOM CLIP T 3.000 1.316 SLOT FOR -T 3/8" HEX BOLT SLOT FOR 1.385 ' 1/8" HEX BOLT .387 .7501.207 — Y Y 1.875 A b-X ►x SOLARMOUNT Beam SOLARMOUNT HD Beam Dimensions specified in inches unless noted SOLARMOUNT Technical . . . - - me UNI I RA.:C I SOLARMOU T Beam Connection Hardware SOLARMOUT L-Foot Part No. 304000C, 304000D • L-Foot material:One of the following extruded aluminum alloys:6005- T5, 6105-T5,6061-T6 • Ultimate tensile: 38ksi,Yield:35 ksi Finish: Clear or Dark Anodized • L-Foot weight:0.215 lbs(98g) • Allowable and design loads are valid when components are assembled with SOLARMOUNT series beams according to authorized Bea UNIRAC documents ----Bolt L-Foot For the beam to L-Foot connection: •Assemble with one ASTM F593 W-16 hex head screw and one errate ASTM F594'/"serrated flange nut Flange N •Use anti-seize and tighten to 30 ft-lbs of torque r Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third-party test Y results from an IAS accredited laboratory NOTE: Loads are given for the L-Foot to beam connection only; be N'X sure to check load limits for standoff,lag screw,or other attachment method 3.oc Applied Load Average Safety Design Resistance T FORDirection Ultimate Allowable Load Factor, Load Factor, �ruow lbs(N) lbs(N) FS lbs(N) 4) Sliding,Z± 1766(7856) 755(3356) 2.34 1141 (5077) 0.646 Tension,Y+ 1859(8269) 707(3144) , 2.63 1 1069(4755) 0.575 Dimensions specified in inches unless noted Compression,Y- 3258(14492) 1325(5893) 1 2.46 1 2004(8913) 1 0.615 Traverse,X± 486(2162) 213(949) 1 2.28 323(1436) 0.664 SOLARMOUNT ' DatashIM SOLARIVIOUNT Mid Clamp §,wf No. 312101(:.3121011),3022103D,302104D, 021050,302106D Mid clamp material: One of the following extruded aluminum d Bolt alloys: 6005-T5, 6105-T5,6061-T6 Mldla CIA MP Ultimate tensile:38ksi, Yield:35 ksi mp _N' Finish: Clear or Dark Anodized Mid clamp weight: 0.050 lbs(23g) .,� Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SOLARMOUNT series beam to retain a module in the direction indicated • Assemble mid clamp with one Unirac'/4'-20 T-bolt and one '/4'-20 ASTM F594 serrated flange nut Use anti-seize and tighten to 10 ft-lbs of torque 840M Use factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- party test results from an IAS accredited laboratory Applied Load Average Allowable Safety Design Resistance 1.00 OISTAKE Direction Ultimate Load Factor, Load Factor, s eN�©au�Es a . .. lbs(N) lbs(N) FS Ibs(N) 0 Tension,Y+ 2020(8987) 891 (3963) 2.27 1348(5994) 0.667 Transverse,Z± 520(2313) 229(1017) 2.27 346(1539) 0.665 Y _ Sliding,X± 1 1194(5312) 1 490(2179) 1 2.44 741 (3295) , 0.620 ►X Dimensions specified in inches unless noted SOLARMOUNT nd Clamp P ari No,302001C,3020021).3020(321),302003C, 302003L)a 3O2OU4C,302t}04D,3a2005C.302005D, 302006s,302.006n,3020071).3020080,302003D, 3020090,302003£3,3d2010C,3020110.302€t12C: End clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5,6061-T6 Ultimate tensile:38ksi,Yield: 35 ksi X♦ 9 Finish: Clear or Dark Anodized ,- End clamp weight: varies based on height: —0.058 lbs(26g) d Clamp Allowable and design loads are valid when components are Seta# assembled according to authorized UNIRAC documents ilalr►ge Nutl'-- Values represent the allowable and design load capacity of a single end clamp assembly when used with a SOLARMOUNT series beam to retain a module in the direction indicated • Assemble with one Unirac'/"-20 T-bolt and one'/4'-20 ASTM F594 s `Bea serrated flange nut • Use anti-seize and tighten to 10 ft-lbs of torque r Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- Y party test results from an IAS accredited laboratory . " Modules must be installed at least 1.5 in from either end of a beam .x ,.K Applied Load Average Allowable Safety Design Resistance MINIMUb. Loads Factor M' Direction Ultimate Load Factor, , , lbs(N) lbs(N) FS lbs(N) 0 HEIGHT WITH$ Tension,Y+ 1321 (5876) 529(2352) 2.50 800(3557) 0.605 MOOULC Transverse,Z± 63(279) 14(61) 4.58 21 (92) 0.330 r Dimensions specified In inches unless fluted Sliding,X± 142(630) 1 52(231) 2.72 79(349) 0.555 SOLARMOUNT ■ Technical . . ' ' ■d"' U N I R A C SOLARMOUNT Technical Datasheet Pub 130817 SOLARMOUNT Module Connection Hardware............................................................ 1 BottomUp Module Clip.................................................................................................1 MidClamp ....................................................................................................................2 EndClamp....................................................................................................................2 SOLARMOUNT Beam Connection Hardware................................................................3 L-Foot...........................................................................................................................3 SOLARMOUNTBeams....................................................................................................4 SOLARMOUNT Module Connection Hardware SOLARMOUNT Bottom Up Module Clip Part No. 302000C Bottom Up Clip material: One of the following extruded aluminum Bottom ( ,, 'e alloys:6005-T5,6105-T5, 6061-T6 Up ClipUltimate tensile: 38ksi,Yield:35 ksi • Finish: Clear Anodized • Bottom Up Clip weight: —0.031 lbs(14g) Beam Bolt Allowable and design loads are valid when components are assembled with SOLARMOUNT series beams according to authorized UNIRAC documents •*�, *��� Assemble with one'/4"-20 ASTM F593 bolt,one'/4"-20 ASTM F594 serrated flange nut, and one 1/4"flat washer ` Use anti-seize and tighten to 10 ft-lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- party test results from an IAS accredited laboratory • Module edge must be fully supported by the beam * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut Applied Load Average Allowable Safety Design Resistance Direction Ultimate Load Factor, Load Factor, lbs(N) lbs(N) FS lbs(N) 4) �l e.a4 Tension,Y+ 1566(6967) 686(3052) 2.28 1038(4615) 0.662 t. Y Transverse,X± 1128(5019) 329(1463) 3.43 497(2213) 0.441 ♦ 1.00 x Sliding,2± 66(292) 27(119) 2.44 41 (181) 0.619 Dimensions specified in inches unless noted a quick Mount PV 925-478-8269 • www.quickmountpv.com • info@quickmountpv.com 2700 Mitchell Dr.,Bldg 2 • Walnut Creek,CA 94598 @ 2013 by Quick Mount PV.All rights reserved. Reference and Tips Proper Flashing Placement g �il���I���IIIII�II�V 4�i1 � i i _ � � ► , ,: 4h 3 Additional tips and information for installing mounts: ■ See Classic Composition Mount install and Quick Tips videos on nail removal,bolt prep,and more at: www.quickmountpv.com/support/videos.htmi ■ It is not necessary or advisable to use nails or other fasteners to secure the perimeter of the flashing. ■ The Classic Composition Mount is made to work with standard and high-definition composition/ asphalt and wood shingle roofs with 5"to 5-5/8"courses.If the exposed surface of the course exceeds this measurement you may need to use our Classic Shake Mount instead. ■ Depending on the season and climate,size and location of seal tabs,and quality of the shingles, the seal tabs that adhere the shingle courses together may not effectively seal the shingles to the flashings.If this is the case,simply add several quarter-sized dabs of manufacturer accepted sealant or asphalt roofing cement,meeting ASTM D 4586 Type II,between the flashing and the shingle above. ■ Mounts should not be installed In areas of the roof susceptible to ice damming.Water ponding under the shingles can reach the bolt penetration. ■ Take care not to damage the roofing material while working on the roof. Removing stone granules and deforming the shingles in any way can shorten the lifespan of the roofing.The value of the solar array is directly affected by the condition of the roof it is attached to. BI 7.2.3-7 Sep-2013,Rev 6 Classic Composition Mounting Instructions Installation Tools Required:tape measure,roofing bar,chalk line,stud finder,caulking gun,sealant compatible with roofing materials, drill with 7/32"long-style bit,drill or impact gun with 1/2"deep socket. !UICK Mount r'T prociucts are-r-4.I clesignect tor ancl snoula 0-41 ne useci to ancnor rall protection equipme"n 1 C 1 Locate,choose,and mark centers of rafters to be Carefully lift composition roof shingle with roofing Insert flashing between 1st and 2nd course.Slide mounted. Select the courses of shingles where bar,just above placement of mount.Remove nails up so top edge of flashing is at least 3/4"higher mounts will be placed. as required. See "Proper Flashing Placement"on than the drip edge of the 3rd course and lower next page. flashing edge is above the drip edge of 1 st course. Mark center for drilling. ���4y��'k����d p III • � � S, �I v' r Using drill with 7/32"bit,drill pilot hole into roof Clean off any sawdust,and fill hole with sealant Slide flashing into position. Prepare hanger bolt and rafter,taking care to drill square to the roof. compatible with roofing materials. with hex nut and sealing washer. Insert into hole Do not use mount as a drill guide.Drill should be and drive hanger bolt until QBlock stops rotating 'long style bit'aka'aircraft extension bit'to drill a easily.Do NOT over torque. 3"deep hole into rafter. moduleYou are row ready for the rack of your choice. Follow all the directions of the rack manufacturer as well as the All roofing manufacturers, written ' instructions must also be • • -• anyoneby • roof system. r Please consult •• specs • instructions prior • -w • •- x a Insert EPDM rubber washer over hanger bolt into Using the rack kit hardware, secure the racking block. (L-foot) to the mount using torque specs from racking manufacturer.If racking manufacturer does not specify torque setting,tighten to 13 ft.-lbs. BI 7.2.3-7 Sep-2013,Rev 6 Classic Composition Mount I AMSC —THIS EDGE TOWARDS RACKING COMPONENTS 2.50 ROOF RIDGE N1 NOT INCLUDED II 1 II u 1 J 6 8 5 7 4 12.00 3 1.50 2 3.00 1 ITEM DESCRIPTION QTY. NO- 6.00 1 FLASHING, 12"X 12"X.050",5052,MILL 1 12.00 2 QBLOCK,CLASSIC,A360.1 CAST AL,MILL 1 3 HANGER BOLT,PLAIN CENTER,5/16"x 6", 18-8 SS 1 ^t ' 4 WASHER,SEALING, 5/16"ID X 3/4"OD,EPDM BONDED SS 1 I t 1 I 5 NUT,HEX,5/16-18,UNC-2B, 18$SS 2 k4 6 WASHER,FLAT,19/64"ID x 7/8"OD x 1/8" EPDM 1 1.30 7 WASHER,FENDER,5/16"ID X 1"OD, 18-8 SS 1 8 WASHER,SPLIT-LOCK,5/16"ID,18-8 SS 1 3.00 Quick Mount PV TITLE: -- AMSC: CLASSIC COMPOSITION MOUNT AVAILABLE IN MILL,CLEAR ANODIZED, AND BRONZE ANODIZED FINISHES. UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN INCHES SIZE DRAWN BYRAD REV : FOL RACTIONAL:I/B A DATE: 7/23/2013 6 FRACTIONAL-S rHOKMIMI'11100011110[NIMI TWO PLACE DECIMA. !.IB A WHOLEIF RWITHOUT THENWRI�NIPERMISSSIION Of QUICK MOUNTPV6R PROHpIIEDKMouNTPV ANY REPRODUCTION WPAFr OR AS DOILOT SCALE DRAWING THREE PLACE DECIMAL!125 SCALE.1'4 WEIGHT 1.24 SUED 1 OF 5 4 3 2 Lag I)LI11-OUt(withdrawal)capacities(lbs)In typical uniber: j Lag Bolt Specifications --------------- Specific Gravity ? 5i16"shaft per 3"thread depth 5;16"shaft per 1"thread depth 1 Douglas Fir,Larrh .50 798 266 i Douglas Fir,South .46 705 235 i..................................................__..___...._....._..._.............._..........................................................................._......_._................................. ......... ..............__....___....._.........................__......................................................................_..................___......................__........................_...,...................................................................... Engelmann Spruce,Lodgepole Pine(MSR 1650 f 3 higher) ,48 705 235 ------._.._,____.._. --_._....._-------- _--__.._._....._.._i Hem.Fir 1 .43 636 212 fiem.Fir(North) .46 705 235 Southern Pine .55 921 307 ......._..._..............................................._................................_._........................___..................._........_..........................................................................._..."`__..........._......._._.........................................._...................................._.................._.._.._.....,....._...__..........................................._...................__..._............_......_...........; Spruce,Pine,Fir .42 675 205 Spruce Pine,Fir(E of 2 million psi and higher grades of MSR and MEL) 50 798 266 Sources:American Wood Council,NDS 2005,Table 11.2 A,11.3.2 A Notes: 1)Thread must be embedded in a rafter or other structural roof member. 2)See ND5 Table 11.5.1 C for required edge distances. uick MountPv ` 0® BI 7.2.3-7 Sep-2013,Rev 6 13inr,lk dc-n:rarn of PV-',007/600 'i L-CCI_;..1 D •---------• •------------------------------------------------------------------------------- MPPT 1 INVERTER + + OC/DQ BULNCAPS (DC/ACI / LINE GRID PARALLEL INl l(+)' '-`f�f CM— + + (DFILTER RELAY N1IN1 t INl INtu"^. ' L1 f ; I y I IN11(1 t I t I AFRI ' I I I ' , t N] IN] IN] , y' MPPT] T I IN]1() ' -- 'IN1' RESIDUAL CURRENT -A VERSION STANDARD VERSION ; DETECTION ' _ I ' I-II PE RS4B5 1 +T/R T T/R DSP, QSP RTN ______ ___ _____u____1__-_-______a CoN7R Ct7tiFR.'- REMOTE CONTROL•, `--------' �j +R I GROUND � : �,I T -R FAULT I DETECTION ALARM ' NC GONtt40LCBitUR NO _ C Remote control function not available on A version PVI-6000/6000-QUTD-US PVI'-5000/6000-©UTD-US' 10: �Illjlli�ii�"r +F80- 47 Pi, 96,5 98, 40096 2 195,9 97-- 95 7 95,fi - 96 45 3 95! -,_._.-_.__. € 345 MPPT 95 Z _94 Voteage 944 W 94,11 93 92 ...2 Vdc 93.:3 S 93 385 Wit 93,2 91 aeautle 95,9 92:9 90 50-. 92A 0 10 2D 30 40 5D 60 1`D'. 80 90 100 %of Ree Wput Power 10% 21* 30%. 50% 75%� 100% 9eetRatsdgot,Power Technical data and types Type code PVI-5000-OUTD-US PVI-6000-OUTD-US Mechanical specifications Enclosure ratingNEMA 4X . . . .. ............ ...... .. .... ... ... . . Cooling Natural convection Dimensions(H x W x D) 41.4x12.8x8.6 in(1052 x 325 x218 mm) .. .......... . .... ..... . .. .. ..... . ....... ........ ... ... Weight <59.51b(27.0 kg) . ..... ......... ......... ........ Shipping weight <78b(35.4 kg) Mounting system Wall bracket Conduit connections Trade size KOs:(2ea x 1/2") and(2ea x 1-1/4",3 places side,front, rear) DC switch rating(per contact) 25A/600V Safet Isolation levelTransformerless(floating array) .. ......... ....... .. .. .. .. .. . .... .. ... ....... .. .......... .. Safety and EMC standard UL1741, IEE1547, IEE1547.1,CSA-C22.2N. 107.1-01,OL1998 UL 1699B,FCC Part 15 Class B Safety Approval CSA, Warranty Standard warranty 10 years ... ........ . . ....... .. .... ... ..... .. .... . ....... ....... .......... ..... .. .. . .. . . . . ..... ............... .. ....... ...... .. .. ...... .. .. . Extended warranty 15&20 years Available modela Standard with DC switch-floating Array PVI-5000-OUTD US PVI-6000 OUTD-US With DC switch,wiring box and arc fault detector and PVI-5000 OUTD USA PVI-6000 OUTD US-A interruptor.. ....... data is subject to change without notice Product flyer for PVI-5000/6000-TL-OUTD I ABB Solar Inverters 3 Additional highlights: r� — RS-485 communication interface (for connection to laptop or data logger). — Integrated Arc Fault Detection and Interruption (-A Version). t t Technical data and types Type code PVI-5000-OUTD-US PVI-6000-OUTD-US Input side Nominal output power 5000W 6000W ................. ........ ............ 1111.. ..... 1111 ...........1111 . 1111 Maximum output power 5000W 6000W Rated grid AC voltage 208V 240V 277V 208V 240V 277V Inpi side C Number of independent MPPT channels 2 Maximum usable power for each channel4000W Absolute maximum voltage(Vmax) 600V Start-up voltage(Vstart) 200V(adj. 120-350) . .......... ..... . ...... ............. ...... .. .... ... ... ....... ... .. Full power MPPT voltage range200-530V ........... 1111.. Operating MPPT voltage range 0.7 x Vstart-580V ..................... ... ............ .... ... .... Maximum current(Idcmax)for both MPPT in parallel 36A ... .......... ....... ............ .......... . Maximum usable current per channel 22A Number of wire landing terminals per channel 2 Pairs ........ . ............... . . 1111.... Array wiring termination Terminal block,pressure clamp,AWG16-AWG6 Outpi3t side(AQ Grid connection type1O/2W Split-0/3W 1O/2W 1O/2W Split-0,13W 1O/2W Adjustable voltage range(Vmin Vmax) 183V-228V 221 V 264V 244V 304V 183V-228V 211 V-264V 244V-304V Grid frequency 60Hz Adjustable grid frequency range 57-60.5Hz ........... ............. ...... . ... ........1111. .. ............ Maximum current(la°,ma.)A 27ARMS 23ARMS 20A 30A 28A 24A ......... 1111. .. 1111........AMS .......... . ........... 1111.. 1111 1111 ......RMS... '. ......... AMS.. .. .RMS .. RMS... Power factor >0.995 Total harmonic distortion at rated power <2% ........ ....... . ........ Contributory fault current' 36.25 APk/ 36.5 APk/ 31.75 APk/ 36.25 APk/ . 36.5 APk/ 31.75 Ate/ 25.63A.�MS 25.81 ARMs. 1111 22.45ARMs.... ._25.63A,MS. 25,81ARMS. 22.45A' .. Grid wiringtermination type Terminal block,pressure clamp,AWG 14-AWG4 Reverse polarity protectionYes Over-voltage protection type Varistor,2 for each channel PV array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) Output Anti-islanding protection Meets UL 1741/IEEE1547 requirements Meets UL 1741/IEEE1547 requirements Over-voltage protectiontype Varistor,2(L,-Lz/L,-G) Varistor,2(L,-Lz/L,-G) Maximum AC OCPD Rating 35A 30A 25A 40A 35A WA E freionoY Maximum efficiency97.1% CEC efficiency 96% 96.5% 96.5% 96% 96.5% 96.5% User interface Graphic display Graphic display Operating fvmance Stand-by consumption .. 1111... <8WRMS: <8WRMS Night time consumption <0.6W <0.6W Commurfmtion User-interface16 characters x 2 lines LCD display ........... .. ... ............ .. ............ Remote monitoring(1 xRS485 incl.) VSN700 Data Logger(opt) .............. ... ............... ...... ............. ...... ............... ............ ................... ...... .. .......... Wired local monitoring(1xRS485 incl.) PVI-USB-RS485_232(opt.) Ert,Arontrteni Ambient air operating temperature range -13°F to+140°F(-25°C to+60°C) 13°F er ting ab ve 12 to+60°C)with ... ... .... .. .. .. ..... ........... .. .................. . ...........derating..above.122°F.(5�°�) . Ambient air storage temperature range -40°F to+176°F(-40°C to+80°C) -40°F to+176°F(-40°C to+80°C) ........... .......... Relative humidity 0-100%RH condensing 0-100%RH condensing Acoustic noise emission level <50 db(A)Q1 m <50 db(A)@1m Maximum operating altitutde without derating 6560 ft(2000 m) 6560 ft(2000 m) .... 11 .1. 1........... ......... ........ 2.Inverter can apply that much current-Breaker will open 2 Al Solar Inverters I Product flyer for PVI-5000/6000-TL-OUTD A" p Designed for residential and small The wide input voltage range Highlights: commercial PV installations, this makes the inverter suitable to low _ Single phase and split phase output inverter fills a specific niche in the power installations with reduced grid connection. ABB product line to cater for those string size. — Wide input range for increased The transformerless operation offers installations producing between stringing flexibility, 51 and 20M high performance efficiencies of up to - The high speed and precise MPPT 97.1%. algorithm offers real time power i itorng capability This inverter includes dual input Free remote montracking and improved energy section to process two strings with available with every installation. This harvesting. independent MPPT. enables homeowners to view their — Outdoor NEMA 4X rated enclosure The high speed and precise MPPT energy production and offers installers for unrestricted use under any a proactive and economic way of algorithm offers real-time power environmental conditions. tracking and energy harvesting. maintaining and troubleshooting the — Integrated DC disconnect switch Flat efficiency curves ensure high system. In compliance with international efficiency at all output levels ensuring Standards(-S Version). consistent and stable performance across the entire input voltage and output power range. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. Power and productivity ®® ®� ®� for a getter worldT, SUN • • E20/333 and E201327 SOLAR PANELS MODELS; SPR-333NE-WHT-D, SPR-327NE-WHT-D ......... . ...... ..... ELECTRICAL DATA IN CURVE Measured at Standard Test Conditions ISTC]:Inadianost 1 W➢w/ms,AM 1.5,and Dell tempmhim 250 c .��_ .... ...._ _ -.-.. .... .....-.. ....-..... ..._.-- Nominal Power(+5/-0%l Priam 333 W 327 W 7 Cell Efficiency rl 22.9% 22.5% 6 1000 W/m2 Panel Efficiency rl 20.4% 20.1 % Q 5 Rated Voltage Vmpp 54.7 V 54.7 V C 3 _,. .__..... .,. , Rated Current 1,pp6.09 A 5.98 A 0 4 Open-Circuit Voltage Voc 65.3 V 64.9 V Short-Circuit Current Isc 6.46 A 6.46 A 200 W/ma 0 Maximum System Voltage IEC 1000 V 0 10 20 30 40 50 60 70 Temperature Coefficients Power(P) -0.38%/K Voltage M Voltage(Voc) -176.6 mV/K Current/voltoge characteristics with dependence on irradiance and module temperature. Current(Isc) 3.5 mA/K NOCT 45°C+/-2°C TESTED OPERATING CONDITIONS Series Fuse Rating 20 A Temperature -40°C to+85a C Limiting Reverse Current(3 strings) IR 16.2 A Max load 550 kg/m'(5400 Pa),front(e.g.snow - Grounding Positive grounding not required w/specified mounting configurations 245 kg/m'(2400 Pal front and back(e.g.wind) ELECTRICAL DATA Measured at Nominal Operating Cell Temptsahxe INOCTt:Irradiance 800W/m2,200 C,wndlm/s Impact Resistance Hail:25 mm at 23 m/s Nominal Power Pnom 247 W 243 W Rated Voltage Vmpp 50.4V 50.4V WARRANTIES AND CERTIFICATIONS Rated Current Impp 4.91 A 4.82 A Warranties 25-year limited power warranty Open-Circuit Voltage Vac 61.2 V 60.8 V 10-year limited product warranty Short-Circuit Voltage Isc 5.22 A 5.22 A Certifications IEC 61215 Ed.2,IEC 61730(SCII) . ....... .. MECHANICAL DATA ............. Cells 96 SunPower Maxeon'cells Output Cables 1000 mm cables/Multi-Contact(MC4)connectors Front Glass High-transmission tempered glass with anti-reflective(AR)coating - Frame Anodised aluminium alloy type 6063(black) Junction Box IP-65 rated with 3 bypass diodes 32 x 155 x 128 mm Weight 18.6 kg DIMENSIONS �b MM (A)-MOUNTING HOLES (B)-GROUNDING HOLES ' (IN) 12x 06.6[.26] 1Ox 04.2[.17] � d E iB) BRIH ENDS h w (A) Please read safety and installation instructions before using this product, visit sunpowercorp.com for more details. 0 2011 SunPower Carp—tion.SUNPOWER,the SunPower Logo,and THE WORLD'S STANDARD FOR SOLAR,and MAXEON are fr d marks or mgmismd trademarks s u n p o w e r e o r p.c o m of SunPower Carporotion n the US and other countries as well.All Rights Reserved Specifications included to the dotosheet ire su6led to change without notice Document#001-65483 Rev'B/A4_EN S U N POWE R E20/333 and E20/327 SOLAR PANELS 20% EFFICIENCY uu "ower F20 parcels are the highest ef'ic ercy :i nel5 at,, -,ho market today, `. ;)i'CJ!r _S orovicing more power in the 5arne amount of space TRANSFORMERLESS INVERTER COMPATIBILITY Comprehensive inverter commpatibiiay ensures that ciustomer5 can pair tfle highest- off cienc`y panels with the F ighest Aiciency inverters, rnoximixing systema output POSITIVE POWER TOLERANCE Positive tol(_rance ensures customers t CUPERTINO receive the rated po./der or higher f tildirlc� [�aprk►>1E311S V -., fog every panel RELIABLE AND ROBUST DESIGN THE `JVORLD'S STAf4 A4r'FOR,�SOLAR . L j SunPowe"S unique 1,0cxeor " cel' Jun c)vver1 E20 Solas `Gllels prc,vicle a ._ f,.irhESt effl�ZlT� teChh<;)IoC)y and adVan...f..0 ??OdUI(;: r.)erfOr'7;cr?CE:. ra)1AJE;rE'o by ..'Ur' er l%4(]X2on����� cell teCl"1rKilC)g'y'; the :...lU destctn ensure In&stry-leading res ability cErl?; prv'dIUeS pc^od conversion offic e":Cl^ 5 of ',iE: to Gf1E _:20Y5 Icvv ;cltage .-emoerature coefficient, arti-ref'ectve ciclss cn.,I exceptional low-lighl perf.xrnan:_e oitiibutes QfovidE er''el``^y delivery per Neck power wall, SUNPOVVER'S HIGH EFFICIENCY ADVANTAGE _.... ( F 9 y E E 71 N MAXEON" CELL ::.E ,_ s TECHNOLOGY w Par.- It back s c rt 'u ell, C E PV CYCLE L o>ding rhe n r. ie t elhc-ienc,acid reliab lihr. www.sur DowerCerD.Camuk SCREW: E1276 MATERIAL:COPPER,XOC7309 TOLERANCES-UNLESS OTHERWISE SPECIFIED DWG. NO. 2 PL.DEC ±.015 TRUE C.L.±.015 CAT. NO.: PLATING:SEE CHART 3 PL DEC.*.010 ANGLES t11 G0977 MASS:.052 LBS. MARKING: O GBL-4DB,4-14,CU, DB ©12 DRAWN BY:CLH SCALE: 3:1 SHEET 1 OF 1 SURFACE AREA: 2.738 INZ DATE:7/27/2007 SIZE: A STUFFER SHT: FORM 12 CELL:ABM REV.1 DESCRIPTION 1/4-28 UNF-2B I x/.040 MAX X 45° Cat # : GBL-4 D B I 0.218 THRU GBL-4 D BT .375±.015 E1276 [9.53±.381 / � I SCALE 1 : 1 .213 .190 [5.41] [4.84] .470 OPENING MUST SLIP A 0.250 PIN .825 [20.96] ---- .185±.005 [4.70±.131 - - 1.150 PART NUMBER PLATING MARKING [29.21] G0977AOOB BRIGHT DIP GBL-4DB,4-14, CU, DB G0977AOOT I EL-TIN GBL-4DBT,4-14,CU, DB ED)GA THE INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPRIETARY TO ILSCO AND MAY NOT BE DISCLOSED WITHOUT PRIOR WRITTEN CONSENT COMMUNrrY DEVELOPMENT DEPARTMENT KEY NOTES: APPROVED 13 This set of plans and specifications MUST be kept thk p 10 (20) SUNPOWER E20-327 job site d n9 con cti_ . It i unlawful ma�arry Of M SOLAR MODULES W/QUICKMOUNT QMNCS ch an I r altera ' --o e, or to c eviato Z200m AT 72" MAX. therefrom, w t val om 9 mal. ,the Buildi Orn � Q e Sta i g of th pl and 'fications Q U o 2❑ (1) ABB PVI-6000-OUTD-S-US-A hel to- ermit or be an a�p oval of th v on U z opLLLro I N THE GARAGE any pr ions any City Ord an or tat �' 0 O �* O (E) 150A SUB PANEL ❑ - Of O w -..�� �s`�� Z INT HE GARAGE oobg ,� - N G CD Z v 4 NOT USED .o0zf ;�• 12O M U)y Asa ❑ °osc p +go• M � 5� NOT USED otic , 60 NOT USED 0 - — - -- - -- -- - -- I- o 7❑ JUNCTION BOX SOLAR LAYOUT 2 1 3 8 W o N AZIMUTH: 90°, 180°, 270° '` ;�I='ERTI O< L)V � 8❑ 3/4„ EMT (IN THE ATTIC) SCALE: 3/32" = 1'-0" 4'-2" „InIn9 Depa ertw Z O 10 MIN. BELOW ROOF SURFACE. O � Z � 1 3 6 201,4 > � I--- co 10 DRIVEWAY _ 0000 w opt -. 9❑ (E) 200A MAIN SERVICE PANEL - , AND METER U 11 WALL BELOW I 12 36" FIRE CLEARANCE 9 I 13 (E) ROOFTOP EQUIPMENT/ -- -- - - - VENT PLOT PLANS W CHECKED BY Z 1 ODAA �G C 10 OFF10 Y--z PLANNING DEPT. .L;& W DATE Q JUNIPER CT. RI,Der. IrFn r — KEY: SYSTEM SUMMARY SHEET NUMBER SHEET TITLE w PROPERTY LINE INVERTER JURISDICTION INFORMATION: (r- CONDUIT RUN R SUBPANEL GRID TIE 6.54 KW DC,6.16 KW CEC AC JURISDICTION: CITY OF CUPERTINO PV 1 COVER & SITE PLAN STRUCTURES E DC DISCONNECT ROOF MOUNTED SOLAR ELECTRICAL SYSTEM ADDRESS: 10300 TORRE AVE. PV 2 LAYOUT & STRUCTURAL BY: DATE: SOLA RIVEWAY nc WITHOUT ENERGY STORAGE COMPONENTS AC DISCONNECT CUPERTINO, CA 95014 PV 3 ELECTRICAL DETAIL JO 09/26/14 D MODULE JUNCTION BOX PHONE NUMBER: 408-777-3228 "N I MAIN SERVICE ©MONITORING UNIT CONSISTS OF: PV 4 LABELS �` , 0 METER ce COMBINER BOX (20) SUNPOWER E20-327 �/ 1 ABB PVI-6000-OUTD-S-US-A MODEL: SUNPOWER E20-327 WEIGHT: 42LBS >� o WIDTH: 41.2" > ¢ co _ LENGHT: 61.4" O J p U-) v MAX. ROOF LOAD: 2.73 LBS/SQFT 0 Q U o MAX. POINT LOAD: 30 LBS/ATTACHMENT Ln N Z co 0 � w U Z MZU M w J QUICKMOUNT SHINGLE FLASHING AND MOUNT UNIRAC SM L BASE SOLAR MOUNT O 12"MAX. 72"O.C. MAX 12"MAX. Q N TYP. TYP. COMP. SHINGLE W - CONT.ALUM. av RAIL SOLAR PANEL = z CD _ qT � �_ � MOUNTING CLIP O � ? 0�0 co LLJ CL = w p O o O Y 2X4 TRUSS � 0 --� ` – Up g UNIRAC SM 2 24" U TYP U O - — RAIL, TYP. � ag 9 O 4 12 (1) g"x 6" SS HANGER BOLT MIN. 2.25" RAFTER EMBEDME w L L END MOUNTING MID. MOUNTING z Z CLIP,TYP. CLIP,TYP. TYPICAL RACK MOUNT LAYOUT ,� QUICKMOUNT BASE MOUNTING SYSTEM SCALE: 1/2"=1'-0" SCALE: V=V-0' CUPERTINO � rr / �ljdding Department! 0 Fye' t-()R. GOOF COMPLIANCE W- Rev ewed By BY: DATE: JO 09/26/14 PV 2 L oc (E)#2 Alu FROM MAIN PANEL Q FOR DATA IF NEEDED O (E)1WA TO 200A SUB PANEL IN THE GARAGE � Q W M STRING Voc: 349V suBPANEL TO REMAIN Z LO m STRINGS Isc: 6.46A INVERTER 8 WIRING BOX LL J Z 0 I INVERTER 8 WIRING BOX MAIN SERVICE PANEL c) U V O #10 PV WIRE 200 AMP RATED w/ �/� 200 AMP BREAKERS_ Z CO IN FREE AIR TO REMAIN O I I � � (� v> O O W ' a: wo 3Q Q3 Q3 Q3 Z m N I BREAKER (NMLOAD Z PV ARRAY PV ARRAY PV ARRAY PV ARRAY 6FDI FUSE 11-N (E)20D CUSTOMER UTILITY GRID O Z W • LOAD ( NET METER � Q U BREAKER \ M (n J I I A I 6R01J10 I (N)PV BREAKER 95 AMP (E)100A BREAKER 5 5 ^ SOURCE SOURCE SOURCE SOURCE � aRouNo CIRCUIT#1 CIRCUIT#2 CIRCUIT#3 CIRCUIT#4 #8 THWN-2 IN"EMT" I �_ L1 =BLACK ^ O L2=RED to #10 THWN-2 IN"EMT N=WHITE I V O) M POS=WHITE NEG=BLACK GREEN=#8 THWN-2 ^ Q WP-- ti (GROUNDING ELECTRIC CONDUCTOR) I GROUND ^ (� (p #10 THWN-2 T EQ.GR GREEN O Z IT CT > I— co 000 W O O- SunPowerSPR-E20-327 L) V U 1703 Power 327 W 64.9 Voc, 54.7 Vmp, 32 Vnom 6.46 Ise, 5.98 Imp 600 V, UL E42728, NEMA 1,2,3,4,4x,6,12,13 _5. W 1-- A A PV 4-6 -O -U - Z UL 1741, NEMA 3R, IEEE 1547 Calculations for Current Carrying Conductors: Nom Voltage 240 V DC required conductor ampacity KEY EQUIPMENT QTY Max Current 28 A [NEC 690.8(Bx1)]: 1Q (E) MAIN SERVICE PANEL 1 Modules 5 (6.46X1)(1.56)= 6.46A Strings 2 AWG#10, derated ampacity: Q Numberof Inverters 1 (40 0.58)(0.8)= 18.56A ( L)PERTINI Q Q2 INVERTER: ABB PVI-6000-OUTD-S-US-A 1 .. Record low tem 27'F 3ullc�ing �2pi�rtrtl nt Q3 PV SOLAR MODULES: SUNPOWER E20-327 20 Temp Coefficient -0.272%/°C 18.56A > 6.46A ,therefore DC wire size is ira . Q (E) 150A SUB PANEL 1 • � 1 2014 Operating Current 11.96 A AC required conductor ampacity W Q5 NOT USED Operating Voltage 273.5 V (28)(2)(1.25)= 35A ';rVIEVvEb t '. ( '�;�F GOMPL4�;N CE Voc (Temp. Coefficient) 349.02 V Q6 NOT USED Short-Circuit Current 16.15 A AWG#8, derated ampacity: ` � _ice.. DATE: NOTES: • (55X0.82)(1)= 45.1A JG 09/26/14 1. EQUIPMENT GROUNDING CONDUCTOR Max AC Output Current 28A 2. GROUNDING ELECTRODE CONDUCTOR Operating AC Voltage 240 V 45.1A > 35A ,therefore AC wire size is valid. D\/ 3 L � - NEC 690.17-AT JUNCTION BOX, COMBINER BOXES AND O J Z Lo m AC/DC DISCONNECTS. >- 0) r- WARNING ELECTRIC SHOCK HAZARD. O Q DO NOT TOUCH TERMINALS. \00' U Z O TERMINALS ON BOTH LINE AND LOAD SIDES V) v> 3 MY BE ENERGIZED IN OPEN POSITION. 0 0 w U � z Z NEC 690.14(C)(2)-ON AC/DC DISCONNECT: M Z W V_ QU AC PHOTOVOLTAIC DISCONNECT ch U) DC PHOTOVOLTAIC DISCONNECT OPERATING CURRENT: 28A OPERATION VOLTAGE: 240V r O NEC 690.53-ON DC DISCONNECT: MPPT#1 0 0 N UJ OPERATING CURRENT: 11.96A IZ V OPERATION VOLTAGE: 274V = Z 0 (O MAX. SYSTEM VOLTAGE: 349V ti SHORT CIRCUIT RUN: 16.15A > � p co co O NEC 690.53-ON DC DISCONNECT: MPPT#2 LLJ O CL OPERATING CURRENT: 11.96A V OPERATION VOLTAGE: 274V MAX. SYSTEM VOLTAGE: 349V SHORT CIRCUIT RUN: 16.15A NEC 690.35(C)-AT THE INVERTER AND/OR GROUND FAULT INDICATOR LOCATION(AND ALL BATTERY LOCATIONS). WARNING! H ELECTRIC SHOCK HAZARD Z IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE ENERGIZED AND UNGROUNDED NEC 690.35(F)-AT EACH JUNCTION BOX,COMBINER BOX, _ DISCONNECTS AND DEVICE WHERE THE UNGROUNDED �+UPEERTIN W CIRCUITS MAY BE EXPOSED DURING SERVICE. y+' inir F- .Jing Departmf�nK WARNING! ELECTRIC SHOCK HAZARD :.� 'S EEO; 3 d 2Q14 THE DIRECT CURRENT CIRCUIT CONDUCTORS OF THIS > PHOTOVOLTAIC POWER SYSTEM ARE REVIEWEr, r i))P C',OMPLAN UNGROUNDED BUT MAY BE ENERGIZED WITH RESPECT TO GROUND DUE TO Reviewed E LEAKAGE PATHS AND/OR GROUND FAULTS BY: DATE: JO 09/26/14 PV 4