Loading...
14050009 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10470 SIARA ST CONTRACTOR:SOLARCITY PERMIT NO: 14050009 OWNER'S NAME: JASON MILLI It 3055 C'l.(:ARViEW WAY DATE ISSUED:05/01/2014 Ovl'NER'S PHONE: 41 53109693 SAN MAT;O,CA 94402 PHONE NO:(650)638-1028 LICENSED C()N'fRr1CTOR'SDFCLARATION JOB DESCRIPTION: RESIDENTIAL COiINIERCL\L QINSTALL IS ROOFTOP FLUSH MOUNTED PV PANELS License Class Lic.if © (5.1 KW) Contractor Date 1 / 14 1 hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the 0.rformance Of the work for which this permit is issued. Sq.Ft Floor Arca: Valuation:S18000 •ave and will maintain Worker's Compensation insurance,as provided for by Scction 3700 of the Labor Code,for the performance of Ilse work for which this APN Number:342590f 1.00 Occupancy Typc: permit is issued. APPLICANT CFRTIFICATiON 1 certify that 1 have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. 1 agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS SSUANCE OR to building construction,mid hereby authorize representatives of this city to enter upon the abo%e tttentioncd property ibr inspccrion purposes. (We)agree io save 180 DAYS LAS INSPECTION. indemnify mid keep Harmless the Cit)of Cupertino against liabilities,judgrricnts, costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally.the applicant understands and will comply Ve y: with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. RE-ROOFS: Signature �UU C�� i Date ! `J All roofs,half be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection,1 agree to remove all new materials for inspection ❑ 0"'NER-BUILDER DECLARATION � I hereby affirm that I am exempt from the Contractor's Li-cense Law for one of Signature of Applicant; Date: the following two reasons: ALL ROOF COVERIiNGS TO BE CLASS"A"OR BETTER 1,as o«ncr ol'the property,or my emplovees with wages as their sole eompcnsaiion, will do the work,and the structure is not intended or offered for sale(Sec.7041, Business&Protessions Code) 1,as owner of the property,am exclusively contracting with licensed contractor to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec 7044,Business&Professions Code). i have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25333,and 25534. 1 will I hereby affirm ander penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Cenificalc of Consent to self-Insure for Worker's material. Additionally,should 1 use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air eonlaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and 1 have and will maintain Worker's Compensation Insurance, provided for by the Health&Safety Code,S ons 25505,255 3,and 25534. Section 3700 of the Labor Code,for the performance of(hOwner or authorized agent: Date: e work for which this � S/ 1/16 permit is issued. 1 certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,1 CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,1 must I hereby affirm 1ha(there Is a conslruction lending agency for the performance of fonhwlth comply with such provisions or this permit shall he deemed revoked. work's for which this permit is issued(See.3097,Civ C) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating- to elatingto building construction,and hereby authorize representatives of this city to enter upon the above mentioned properly for inspection purposes (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the 1 understand my plans shall be used as public records, granting of(Itis permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupenmo Municipal Code,Section Licensed Professional_ 9 l8 Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION 10300 TORRE AVENUE• CUPERTINO, CA 95014-3255 (408) 777-3228- FAX(408)777-3333 •building aacupertino.org � CUPERTINO ` PROJECT ADDReSS � � (���r0. �� � I APN F ��,/-2 OWNER NAME 10 50n11U ?HON - 3 0- 1 �Q E-MAIL �m y(�`/{j� �� I� { y ) STREET ADDRESS �U l O CITY. STATE,ZIP rl t� FAX CONTACT NAME O'n D Y) PH NE �V EMAIL C -P im SO i cur 6—h, STREET ADDRESS 3qC' Tc, Y,STATE, ZIP �% + k�J FAX OWNER ❑ OWNER-BUILDER ❑ OWN ER AGENT CONTRhCTOR !SJ'CONTRACTORAGENT ❑ ARCHITECT C1 EENGINEER ❑ DEVELOPER ❑TENANT CONTRACTOR^TAME ` , C LICENSE NUMB ER {O t� LICENSE,TYPE C BUS.LSC# COMPANY NAME J J E-MAIL yy"� } `, FAX 01 C ss Corr STREET ADDRESS S V C CITY,STATE,ZIP ARCHITECT/SNO[NEER NAME J LICENSE HUMBER r l• l BUS.LIC# COMP,-,NY NAME E-MAIL FAX I STREET ADDRESS CITY,STATE,ZIP PHONE USE OF )�,SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE. ❑ Commercial URBAN INTERFACE AREA Cl Yes ❑ No FLOOD ZONE C Yes rI No 0_LAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANED NUMBER OF PANELSlUN'ITS: N KILOWATTS: 5- , - I TOTAL VALUATION. DESCRJ°TION OF WORK Y s 1 rn _ S uarOdLAN,0S S v _RECEIVED By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the pro --ovmer's behalf-Tave read this application and the information i have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable iocu: ordinances and state laws relating t uilding constructs l authorize representatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent Date. l SUPPLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY w ❑ OVER-THE-COUNTER �rr E- ❑ EXPRESS U STANDARD zU a ❑ LARGE 4 Q MAJOR PVApp_2012,doc revised 06/20/12 CITY OF CUPERTINO FEE ESTIMATOR -- BUILDING DIVISION ELI ADDRESS: 10470 SERRA ST DATE: 05/01/2014 REVIEWED BY: melissa APN: 342 59 011 BP#: VALUATION: 1$18,000 :-PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration 1 Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RES USE: PERMIT TYPE: WORKinstall 18 roof top flush mounted pv panels 5.1kW SCOPE NOTE: This estimate does not inclurlefees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc. . TheseLees are based on the prelimina information available and are only an estimate. Contact the De t or addn'l info. FEE ITEMS Lice Resolulion 11-053 Eff 7/1/131 FEE QTYIFEE MISC ITEMS Plan Check Fee: $0.00 = # Alternative Energy System Suppl. PC Fee: (j) Reg. © OT0.0 hrs $0.00 $229.00 1PHOTOY Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Supp!. Insp. Fee:Q Reg. Q OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 on.ct miction Tax C Work Without Permit? 0 Yes Q No $0.00 G Advanced Planning Fee: $0.00 Select a Non-Residential G Building or Structure 0 Strom Motion Fee_ 1BSE1SMlCR $1.80 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $2,80 $229.00 TOTAL FEE: $231.80 Revised: 04/01/2014 ABBREVIATIONS ELECTRICAL NOTES JURISDIMON NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING FLASHING WILL BE PAINTED TO MATCH EXTERIOR AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE CONC CONCRETE HAZARDS PER ART. 690.17. f DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THEy � EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY S ' ' "' EE) EXISTING PHASE AND SYSTEM PER ART. 210.5. MT ELECTRICAL METALLIC TUBING 3. A NATIONALLY—RECOGNIZED TESTING , GALV GALVANIZED LABORATORY SHALL LIST ALL EQUIPMENT IN GEC GROUNDING ELECTRODE CONDUCTOR COMPLIANCE WITH ART. 110.3. s � GND GROUND 4. CIRCUITS OVER 250V TO GROUND SHALL t f HDG HOT DIPPED GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) I CURRENT 5. DC CONDUCTORS EITHER DO NOT ENTER 1 Imp CURRENT AT MAX POWER BUILDING OR ARE RUN IN METALLIC RACEWAYS ORt Isc SHORT CIRCUIT CURRENT ENCLOSURES TO THE FIRST ACCESSIBLE DC kVA KILOVOLT AMPERE DISCONNECTING MEANS PER ART. 690.31(E). kW KILOWATT 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN ` S LBW LOAD BEARING WALL RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY MIN MINIMUM UL LISTING. 1 (N) NEW 7. MODULE FRAMES SHALL BE GROUNDED AT THE NEUT NEUTRAL UL—LISTED LOCATION PROVIDED BY THE NTS NOT TO SCALE MANUFACTURER USING UL LISTED GROUNDING UPERTINO OC ON CENTER HARDWARE. t, PL PROPERTY LINE 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE IRA POI POINT OF INTERCONNECTION BONDED WITH EQUIPMENT GROUND CONDUCTORS AND PV PHOTOVOLTAIC GROUNDED AT THE MAIN ELECTRIC PANEL. q SCH SCHEDULE 9. THE DC GROUNDING ELECTRODE CONDUCTOR v SS STAINLESS STEEL SHALL BE SIZED ACCORDING TO ART. 250.166(B) & W REVIEWED FICC I"ODC-. C(DWI,.lANCE STC STANDARD TESTING CONDITIONS 690.47. ,. ' r } TYP TYPICALi �€us `` UPS UNINTERRUPTIBLE POWER SUPPLY j V VOLT Vmp VOLTAGE AT MAX POWER VOLTAGE AT OPEN CIRCUIT W WATT VICINITY MAP INDEX W 3R NEMA 3R, RAINTIGHT JTX2 COVER SHEET SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENEML NOTES CutsheetRE Attached IAGRAM CA # 888104 1. THIS SYSTEM IS GRID—INTERTIED VIA A C-10 UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. 4. ALL WORK TO BE DONE TO THE 2013 MODULE GROUNDING METHOD: ZEP SOLAR CALIFORNIA BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. REV BY DATE COMMENTS AHJ: Cupertino 5. ALL ELECTRICAL WORK SHALL COMPLY WITH REV NAME DATE COMMENTS THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. UTILITY: Pacific Gas and Electric Company 0 � ' .' NUMB CONFIDENTIAL— THE INFORMATION HERJB-9502905 00 PREMISE OWNER: DESCRIPTION: DESIGN: HERON NERp R 114�� � �� � CONTAINED SHALL NOT BE USED FOR THE MILLER, JASON MILLER RESIDENCE Alex ML11draW .`. •, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: — ♦'�` NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hoak tt10470 SEttR11RA ST tt�� 5.1 KW Iry Array PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES- t P E R TI N V A 9 V rI ORGANIZATION, EXCEPT IN CONNECTION NTH � 3055 Ciearview Way THE SALE AND USE OF THE RESPECTIVE (20) CANADIAN SOLAR # CS6P-255PXE�; ; DATE; Son Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE W Mui PAGE NAME: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. INVERTER: PAGE SOLAREDGE SE500OA—US—ZB—U 10- 00.� COVER SHEET IaV 4/22f2014 (888)—SOL—CITY(765-2489)www,salarsity.com PITCH: 29 ARRAY PITCH:29 MP1 AZIMUTH:153 ARRAY AZIMUTH: 153 MATERIAL: Flat Cement Tile STORY: 2 Stories PITCH: 29 ARRAY PITCH:29 MP2 AZIMUTH:243 ARRAY AZIMUTH:243 MATERIAL: Flat Cement Tile STORY: 2 Stories Front Of Nouse ==7/ AC Inv LEGEND (E) UTILITY METER & WARNING LABEL Ing INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS ® DC DISCONNECT & WARNING LABELS a a a ( © AC DISCONNECT & WARNING LABELS a 0 0 0 DC JUNCTION/COMBINER BOX & LABELS ° ° c D DISTRIBUTION PANEL & LABELS ~' CUPERTINO ° ° I E3::ilin LC LOAD CENTER & WARNING LABELS s p (� DEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS —I ' V'E§E",.� ' ` r-;,P 00DE � 'ARI IANGECONDUIT RUN ON EXTERIOR ®®. CONDUIT RUN ON INTERIOR -" GATE/FENCE Q HEAT PRODUCING VENTS ARE RED 1 INTERIOR EQUIPMENT IS DASHED N TOTAL ARRAY AREA (SF): 353 SITE PLAN ty TOTAL ROOF AREA (SF): 4187 Scale:1/16" = 1' TOTAL ARRAY AREA IS sa 8.44 01' 16' 32' F s PERCENT OF TOTAL ROOF AREA J 8---9502905 0� PREMISE OWNER: DESCRIPTION. DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: L7 lJL V 1.1 k p pf q c ® CONTAINED SHALL NOT BE USED FOR THE MILLER, JASON MILLER RESIDENCE Alex MUldrow r BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: Ft ` NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 1tt��0470 SERRA ST 5.1 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: t�U R E R TI N 0 C A 9 5014 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 0eorvEew Way THE SALE AND USE OF THE RESPECTIVE (20) CANADIAN SOLAR # CS6P-255PX SHEET: REV. DATE: San Mateo,CA 9402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME T:(650)638-1028 F:{650}638-1029 PERMISSION OF SOLARCITY INC. INVERTER: sOLAREDGE sE500oA—Us—ZB—U (415) 310-9693 SITE PLAN PV 2 4/22/2014 (888)-SOL—CITY(765-2489)www.so}arc6tycom si si 6" 5$ 6' A (E) LBW (E) LBW SIDE VIEW O MP1 NTS SIDE VIEW {J MPS NTS MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES mpi X-SPACING X-CANTILEVER Y-SPACINGIY-CANTILEVERI NOTES LANDSCAPE 72" 24" 45" 24" LANDSCAPE 7211 24" 45" 24" PORTRAIT 48" 19" 60" 24" PORTRAIT 48" 1911 60" 24" RAFTER: 2x8 @ 24"CIC ROOF AZI 153 PITCH 29 STORIES: 2 RAFTER: M @ 24" OC ROOF AZI 243 PITCH 29 STORIES: 2 ARRAY AZI 153 PITCH 29 ARRAY AZI 243 PITCH 29 CJ.: 2x6 @16"OC Flat Cement Tile C.j.: None @24" OC Flat Cement Tile INSTALLATION ORDER ZEP SPANNER BAR LOCATE RAFTER, MARK RAFTER (6) LOCATION, AND REMOVE TILE. PLACE STANDOFF BASE & DRILL PILOT HOLES AT THE RAFTER LQQATION. DIA BOL T & NUT (2) i(f 7)If 3) I CLEAN PAPER ARO U ND PILOT RE"y' EVEFO HOLE BCUE (;CRT ZEP SPANNER ( BAR CLAMP ADJUST STANDOFF TO BATTEN uildingDep (3) HEIGHT. STANDOFF SEAL PILOT HOLES AND BOTTOM (E) TILE (4)OF STANDOFF WITH POLYURETHANE VID DMPaLIIArI NAtmNOeCn '� (E) ROOF DECKING (4) SEALANT. (5) Rewe,,ped Bir. t - 5/16- DIA LAG BOLT 5) LAG STANDOFF INTO RAFTER. (2-1/2- EMBED, MIN) LOWEST MODULE SUBSEQUENT MODULES (E) RAFTER q�OT�IH 6) NOTCH TILE WEATHERING TO FIT TILE ' sTAI\IDQFF _AROUND STANDOFF. CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9502905 00 ILSELEOMRER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE MPREMI , JASON MILLER RESIDENCE Alex Muldrow BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: JTV NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 10470 SERRA ST 5.1 KW PV Array ,SolarG .70 PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: CUPERTINO, CA 95014 3055 gearview Way THE SALE AND USE OF THE RESPECTIVE (20) CANADIAN SOLAR # CS6P-255PX SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME- SHEET: 'EV., DATESan Mateo.CA 94402 : INVERTER: T-.(650)638-1028 F.(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE #SE500OA-US-ZB-U (415) 310-9693 STRUCTURAL VIEWS PV 3 4/22/2014 (888)—SOL—CITY(765-2489)wwsofordty� UPLIFT CALCULATIONS 04.22.2014 SleekMunt-rm Pv System Version#34.3 j"% Structural Desion Software Rrsk Categpry: TT pv system Type $pjar*sjeekMount'"' Flat Tile Roof Flat Tile Roof rs orf-0-b!i fin Roof Slope 290 E�after� aeEn 2ri";O.C. PV System Module Orientation Landscape and Portrait PV MrF iu{e NOEi6. f PV Module Width 39" Pv module Leri n. Standoff Attachment Hardware Miqhtv Hook HDG FT F,:.eduret;#Girou"nd >Etoolf"give/snow-Coatis Ground Snow Loan pg 0.0 psE ASCE Table 7-1 SuiT';!ettrouEg:.(oof Snovr . Roof snow over IN Modules o.oPA ASCE Ea.,7.4-1 Vitirid Desi n;Griteria. Wind Oesign Code ASCE 7-10 Witt€fDesign."Nefhod attiallyf Fully Eritfitisdd Method Basi" Wind nd Speed V 110 mph Efg 26.5 1A EXpasure,Category C Sectian:2Ei.7 Roof e: GabEe/Hip RooF FV.3a.aaA/a/esAia Mean.ttoof Height to 25,ft" Secfion:252 Effective Wind Area 1 Module A 17.3 sf TBC 1509.7.1 !!Vf nt1,Pressure Calcutaion, 6 .cuts Wind Pressure Exposure I{ 0.95 Table 30.3-1 Topp4Phlc Factcir t<zt i.0 :Sct3an 26x8, Wind Directionality Factor Kd 0.85 Section 26.6-1 Tin rtario FavorJ NA Velocity Pressure qh qh 0.00256(Kz)(�)(Kd)W2)24.9 vsf Equation 30:3_1 Ext:Pressure Coefficient(up) Cp(Up). 0.95 �.3c..a- 5A/9 5A/a "Pressure CDeffiaent DQtivn G f oWiT 0.88': 3a..+2n/e/C,5V8 Deslian Wind Pressure p=gh GCCUPERTINO aHan 30.4-1 "toy of) POP) 23:7psf uilt�if€� ertm t Wind Pressure Down down 21.8 psf ii111tIi'ft4rable.St [id[ii S .. .,t1 * :g s f ' X-Direction -0iititt Max Allowable Sxandoff Spacing Landscape 72" i t�'l 4 " ODE ;%�f���'`UANC Nax'alio6uat}ie 1�ntli�� r LrrlSCai@ 2 " Standoff Confi uration Landscape Not-Staggered Naic$tarrdoffTylbutary>k ea. Tylb 23"sf° ' PV"Assembly Peal Load W-PV 3 psf Net"Wlid t3plift.at Standoff T-actual 28s!tis Uplifit Capacity of Standoff T-allow 500 lbs 5taritipff.l?enia+i i Ca DCf2 56:0/ Max Allowable Meir Allowiable Stancipff ieverSpaang Portrait 48" 60" PYitait ig"` 24" Standoff Confi uration PortraitNot-Staggered 'Max"Stairiiaff Tr bvtaty.Area" 'Too. 20 sf PV Assembly Dead Load W-PV 3 psf Ne>W rdbpllff Standoff T-actaal 2 3"ibs Uplift Capacity of Standoff Tall, 5QO lbs tandoff.Demanl 50:6 " CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE JB-9502905 0 0 MILLER, JASON MILLER RESIDENCE Alex Muldr©w ' BENEFIT OF ANYONE EXCEPT SOLARCtTY INC., MOUNTING SYSTEM TV __ �.� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Nook 10470 SERRA ST 5.1 KW PV Array V. l r • PART TO OTHERS OUTSIDE THE RECIPIENT'S [MODULES-, CUPERTINC) CA 95014ORGANIZATION, EXCEPT IN CONNECTION WITHg THE SALE AND USE OF THE RESPECTIVE (20) CANADIAN SOLAR # CS6P-255PX 3055 eo,CA Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: 5NEET; REV DATE Son M638-1028 attF:{650}638-1029 eo,CA 94402 INVERTER: T:{650} PERMISSION OF SOI.ARCITY INC. 5OLAREDGE SE5000A—US—ZB—U (415) 310-9693 UPLIFT CALCULATIONS PV 4 4/22/2014 {888}-sm-CITY{765-2489}www.solarcitycom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number: Inv 1: DIC Ungrounded INV I - 1 SOLAREDGE #SE500OA-US-ZB-U LABEL: A -�0)CANADIAN SOLAR� CS6P-255PX CA # 888104 5000W, 240V, 97.57.; w/Unifed Disco and ZB, AFCI PV Module; 255 234.3W PTC, Block Frame, MCV, ZEP Enabled C-10 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:1003919592 Inverter, I Underground Service Entrance INV 2 Voc: 37.4 Vpmox: 30,2 INV 31 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E� 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 CUTLER-HAMMER 120OA/2P Disconnect 3 SOLAREDGE SE500OA-US-ZB-U S' SE5001 (E) LOADS aB : L1 N= SolarCity L2 :A]- N %2' N Strings} 30A/2P D --------------------------------------V_EP21 Ikoc+ FfP�W A ————--�GN GEC DC- Dc- Of 20 On MP1,NPi EGLC GND ————————————————————————— ———— --- ———— --------------J N CIEC Z GECL TO 120/240V SINGLE PHASE UTILITY SERVICE CUPErl to RTINO Building Depat-nem '.j R E_V I E V%i E D, FOR GODE C,OW L I A N(1,F Voc* = MAX VOC AT MIN TEMP 'Revipwed By 2!t( )SIEMENS#0230 0452— 2P BREAKER 1 CUTLER—HAMMER#DG221 URB (I)SolorCi 4 STRING JUNCTION BOX 11 Breaker 13OA/2P, 2 Spaces Disconnect 30A, 24OVoc, Non—Fusible,NEMA 3R AC 2x2 S,�&AGS, UNFUSED,GROUNDED DC )Ground Rod; 6/8'x 8', Copper )CUTLER�AMMER�DG03ONB ZEP#850-1196-002 Ground Neutral it, 30A,General Duty(DG) Universal Box Bracket; [PKG 8] PV (20)SOLAREDGE optimizer,NA4AZS PowerBox 30OW, H4,DC to DC, ZEP (I)AWG#10, THWN-2, Block (1 AWG 110, THWN—Z Black Voc* =500 VDC Isc =15 ADC .4 (2)AWG#10, PV WIRE,Block Voc* =500 VDC Isc =15 ADC (1)AWG#10, THWN-2, Red (1)AWG#10, THWN-2, Red Vmp =350 VDC Imp=14.38 ADC (1)AWG#10, Solid Bore Copper EGC Vmp =350 VDC Imp-14.38 ADC (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp 20.83 AAC .4 .47 EMT. . . . . . . . . . . . . . . . . . . .. ... . .. .. . . . . . . . . . .. . .. . .. . . . ... . ... .70 AWq 0,Tlf"72,.Green fqC/pEp.—(1)conduit:Kit-,x/47.EJIMT. . . . . . . . CONFIDENTIAL— THE INFORMATION HEREIN PREMISE OWNER. DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: JB-9502905 00 MILLER, JASON MILLER RESIDENCE Alex Muldrow BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: o,"'Z I-V NOR SHALL IT BE DISCLOSED IN MOLE OR IN 10470 SERRA ST So1arCijL% " PART TO OTHERS OUTSIDE THE RECIPIENT'S ZEP Mighty Hook 5.1 KW PV Array 111070 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES. CUPERTINO, CA 95014 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (20) CANADIAN SOLAR # CS6P-255PX SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: Son Mateo,CA 9W2 INVERTER: T.(650)638-1028 F.(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE #SE5000A-US-ZB-U (415) 310-9693 THREE LINE DIAGRAM PV 5 4/22/2014 (888)—SOL—CITY(765-2489)www.solarcity.com CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: Address: 10470 Serra St UTILITY SERVICE INVERTER AND DC DISCONNECT s "'UPERTINO Isl�a uilding spa€tom`? t r----------------------------� SOLAR PHOTOVOLTAIC ARRAYS) R: V!Dr,1 :U- FOR L:'()DE t; ��1�i�i..t r� PHOTOVOLTAIC BACK—FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 Rc-met"veci By, OPERATING VOLTAGE = 240V MAX CURRENT = 20.83 A CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9502905 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: t� �,q C� �\l CONTAINED SHALL NOT BE USED FOR THE MILLER, JASON MILLER RESIDENCE Alex Muldrow s a BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: J►®' olarCltv NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 10470 SERRA ST 5.1 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENT'S MODu�Es: CUPERTINO CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 CleaNew Way THE SALE AND USE OF THE RESPECTIVE (20) CANADIAN SOLAR # CS6P-255PX SHEET: REV: DATE: San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. SERTER: GE SE500OA—US—ZB—U (415) 310-9693 SITE PLAN PLACARD PV 6 4/22/2014 (888)-SOL-CiTY(765-2459)www.solordty.com Label Location: Label Location: min Labef Location: �m �o �� ��(C)(IC)(CB) (AC) (DC)(INV)(CB) Per Code: Per Code: CRC R331.2 CEC 690.35(F) Label Location: o o +- TO BE USED WHEN (DC)(INV) INVERTER IS Per Code: UNGROUNDED CEC 690.14.C.2 ' Label Location: (DC) Per Code: Labef Location: I�� o o +. � CEC 690.17 m (DC)(INV) ® Per Code: ° o ®� CEC 690.53 »� o� 1, Label Location: (POI) Per Code: g CEC 705.12.D.7 Label Location: o o o + (DC)(CB) Per Code: s CEC 690.17 Label Location: ® o o (POI) + m ' Per Code: CEC 690.54, CEC 690.17 Label Location: SuildingIm�)r jj (INV) Per Code: CEC 690.5(C) o m'o + Reviewed B�. Label Location: Label Location: ME {D}(POI) ® e9 (AC) (POI) Per Code: (AC):AC Disconnect Per Code: CEC 690.64.6.4 (C): Conduit CEG 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: Label Location:{AC)(POI) (POf} (INV): Inverter With Integrated DC Disconnect ME] Per Code: Per Code: (LC): Load Center CEC 690.54 CEC 705.12.D.7 (M): Utility Meter ism (POI): Point of Interconnection CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED v'a��r r� 3n MaCleteo, CA way IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, g S !r ® ® San Mateo,CA 94402 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE �� �� Label ''e� ,r�+z T.(650)63&Y028 89)ww 638-1024 ® (888)-SOL-CrIY(765-2489)wwwsolarcity.eam SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. o SolarCity lee oun TM m Tile SolarCity SleekMountTM ® Tile The SolarCity SleekMount hardware solution Utilizes Zep Solar hardware and UL 1703 listed "> Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules v aesthetics while minimizing roof disruption and Remove file and locate rafter s Interlock and grounding devices in system UL labor.The elimination of visible rail ends and listed to UL 2703 Drill pilot holes of proper diameter for mounting clamps,combined with the addition g .; fastener size per NDS section 1.1.3.2 a Interlock and Ground Zep ETL listed to UL 1703 _ ,.w. of array trim and a lower profile all contribute to „ Q, Seal pilot holes with roofing sealant as"Grounding and Bonding System" a more visually appealing system.SleekMount Place the hook utilizes Zep CompatibleTM modules with e Ground Zep UL and ETL listed to UL 467 as strengthened frames that attach directly to Zep grounding device install lags pursuant to NDS section 11.1.3 Solar standoffs,effectively reducing the number with fender washer ®Anodized components for corrosion resistance of standoffs required, when compared to Notch underside of the and reinstall file conventional rail-based systems. ®Applicable for vent spanning functions >x.,. 3 Attach Spanner Clamps and tighten firmly in place rt insert Cam Foot into Spanner Bar and rotate _ Cam Nut 100 degrees Components Place modules t Gam Foot Spanner Bar rCUPERTINO I . �. I 318"Machine Screw and Nut # uildin f�parl3`sn ! l Spanner Bar Clamp � 4 Tile Hook i� m Lag Screw(2) REVIEWED FOR t 41) Reviewed By. R 10 a . w m � Lw w 9 r �Q��MPAtig� CU qJanuary 2013 _ � � LISTED �t� oia ft o January 2013 CS6P 1 f anSolar ��'s,f�����• - l Electrical Data Temperature Characteristics w STC CS6P 235/ CS6P 240E CS6P 245/ CS6P 250/ CS6P 255PX Nominal Maximum Power(Pmax) 235W 240W 245W 25OW 255W _ Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30.1V 30.2V Pmax -0.43%1'C ® Optimum Operating Current(Imp) 7.90A 8.03A 8.1TA 8.30A 8.43A Temperature Coefficient Vo -0,34%/°C Open Circuit Voltage(Voc) 36.9V 37.0V 37.1V 37.2V 37AV Iso 0.065%rC e Short Circuit Current(Isc) 8.46A 8.59A 8J4A 8.87A 9.00A Normal Operating Cell Temperature 4512°C m n @ Module Efficiency 14.611 14.92% 1 15.23%< 15.64% 15.85% Operating Temperature -40C-+85'C Performance at Low Irradiance Maximum System voltage 1000V IEC&999 UL Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification Class A irradiance of 1000wim'to 200w/m' Next Generation Solar Module Power Tolerance 0-+5w (AM 1.5,25 ) Under Standard Test conditions(STC)of irradiance of 1000W/m',spectrum AM 1.5 and celi temperature 0251C NewEdge,the next generation module designed for multipleEngineering Drawings NOCT CS6P-235P CS6P-240P,CS6P-245P X CS6P•250PX CS6P-265PX types of mounting systems,offers customers the added Nominal Maximum Power(Pmax) 170W 174W 178W 181W 185W value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2V 27.3V 27AV 27.5V 27.6V -- appearance,auto groundingand theft resistance. optimum operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A — Open Circuit Voltage(Voc) 33.9V 34.OV 34.1V 34.2V 34AV The black-framed CS6P-PX is a robust 60 cell solar module short Circuit Currentpscp 6.66A 6.s6A 7.O6A 7.1sA 7.2sA ` . incorporating the groundbreaking Zep compatible frame. Under Normal Operating Cali Temperature,Irrin ianceof800 Winn',spectrum AM 1.5,ambient temperature 20'C, 5 "- wind speed 1 mis i The specially designed frame allows for rail-free fast installation with the industry's most reliable grounding Mechanical Data �i system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 166mm,2 or 3 Busbars ' Key Features silicon cells laminated with a white back sheet and framed CellArraogement 60(6 x 10) With black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x40mm(64.5 x 38.7 x 1.57in) ° Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(46,2 Ills) nil reduces installation time quality aesthetic module with lowest system cost. Front Cover 3.2mm Tempered glassFrame Material Anodized aluminium alloy ° Lower system costs - Cancutrooftop Best Quality J-BOX IP65,3diodes installation costs in half Cable 4mm'(IEC)I12AWG(UL),1 O00mm ® 235 qualify control points in module production Connectors MC4 or MC4 Comparable ° Aesthetic seamless appearance - low profile ° EL screening to eliminate product defects p �,, ' �- with auto leveling and alignment ° Current binning to improve system performance Standard Packaging(Modules per Pallet) 24pcs Module Pieces per container(40 ft.Container) 672pcs(40'HOj INO ° Accredited Salt mist resistant 3, [mina epa ni Built-in hyper-banded grounding system - if it's I-VEArWeS (CS6P-255PX mounted,it's grounded Best Warranty Insurances i Theft resistant hardware ° 25 years worldwide coverage = _. - e � • k irk 100%warranty term coverage section A-A Ultra-low parts count - 3 parts for the mounting ° Providing third party bankruptcy rights °{ _ it } and grounding system ° Non-cancellable ° immediate coverage Industry first comprehensive warranty insurance by i i V t e WE AM Best rated leading insurance companies in the ° insured by 3 world top insurance companies worWi s Comprehensive Certificates == _ ° Industry leading plus only power tolerance:0-+5W = i IEC 61215,IEC 61730, IEC61701 ED2,UL1703, • Backward compatibility with all standard rooftop and CEG Listed,CE and MCS ground mounting systems ° IS09001:2008:Quality Management System e ISOiTS16949:2009:The automotive quality Speeificationsincluded inthis detasheetare subject tochange Without prior notice. ° Backed By Our New 10/25 Linear Power Warranty management system Plus our added 25 year insurance coverage ° IS014001:2004:Standards for Environmental About Canadian Solar y. management system Canadian Solar Inc.Is one of the world's largest solar Canadian Solar was founded in Canada In 2001 and was '9M Adde ° 00080000 HSPM:The Certification for companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) in 90% d Value.From(,yarn Hazardous Substances Regulations manufacturer of ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing anty solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.30W. ° OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide ao% occupational health and safety customers. Canadian Solar's world class team of 0% . j 10Is- 20- -25 ° REACH Compliance professionals works closely with our customers to S provide them with solutions for all their solar needs, e • ... •10 year product warranty on materials and workmanship ED& 00-X .M ado Er=yeas :a 25 year linear power output warranty www.canadiansolar.com f EN-Rer ta.97 Copyright p 2012 Canadian Solartrtc. r� solar=@a :. Solar=@@ z SolarEdge Power Optimizer Module Add-On for North America P300/ P350 1 P400 SolarEdge Power Optimizer 6340 7 Module Add-On For (North America {kor 9400 �� 60•cel)PV t (for 72-cell PV � (for 96,ell PV modules) J{ modules) moduFasj P300 / P350 / P400 INPUT Rated In ut DC Power 300 . 400 W s Ahsaiute Maximum Input Voltage(Vot at lowest temperature} 48 64 I 80 Vdc �3' s.r=, "� (� MPP70 erat7n Ran a8-48 $-60 8-80 ....Vdc ................... .. ............. ......... .... ... ...... .. .. Maximum ....12.5.. .. .. ....A .. ...............1.... .......... ... ., *a fj x .3. Sa, '. '.. x R. za' ................_............... .................,.. ... ..... .,................ .. ........ ...... ........ .... ..... ........44:5 ..,...... ..... ._.... ....%,.... ..... ....... . 98.8 �.. h a T `* f Overvoitage Category II 4 � �s r OUTPUT DURING 07ERATION POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) x* ¢ s 4 `� 5"' ,Maximum Out ut Current 15 Adc. _Maximum Output Voltage _60 ..'mac_."., a ar h „' e OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF} Safety Output Voltage per Power Opttmizer 1 _ 7 Vdc STANDARD COMPLIANCE______ __ �� ... FCC Part1..Class B iEC61000-6 2 tEC61000 6 3 ¢ ............ ......21081{ttass ROHS INSTALLATION SPECIFICATIONS _ _ ¢ Maximum Allowed System Voltage !__.___ 10fN7Vdc _ ^ y �. Dimensions(W x L x H) 143x212x40.5(5.55x8.342158 -in . ................................. ..........................._.,. ......_................... ... ... ...... "` Wei ht tndud4n cables _ 950 2.1 r. '`" s ....R$...1......... ........$......... .......... ,............. ........,........._ ...­ "input .. .... f._. .. ... g yyy''''''{{{;;; in ut Connector Nh;C /Amphenoil7yco ^ Ea'A r � ,;. Output Wire TypelCannectar__ „_,,. Double lnsutated;Ampheno[ 4 �" OutputWaeEengtt o.esla.¢ iz/39 x m { ,• ¢w ... ...._......_............. . q, F,:- - Operating Temperatum Range -40 +85/-40-+185 t •�.. r > � ., ,,,' rateMion Rahn S 5 NEM P 9E iP6 A4 ' . Relative Humidity... .. ... ......_........ ... .._-. .._. 0 ,. Uf acted SrC powe�oftM1@motlule lhoEURof vPM aS%power iWerz:rcealbrvM. is U j (j C jP DESIGN USING A T SE THREESE '^ at ' '. ,.,. .. t. - ..,, • .�.. L' "tJl yds :'. INVERTER THREE A 480V A SOLARED6E SINGLE PHASE �z Minimum String length(Power Optimizen;) 8 10 PV pOWer,Optlrttlzatidii at the M6dule-Ii%ie _.............. ............... ... ._.... .... ...i......,......_....... .. ..... .. ....... Maximum String Length(Power Optimizers} 25 2550 M ^- Up to 25%more energy .............. ­­.......... .....,.... ..,.......... ..............,..... _....E_......... ._..... .._........ .r............. Maximum Power per String 5150 6000 12750 ( W Superiorefflciency(99.5%}'. ............ .... .. _.......... ... .. ...... ... ........._...v_..._........., ........... ..275 ......f........ .. R'Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading Parallel Strings of Different Lengths or Orientations yes Flexible system design for maximum space utilization - Fast installation with a single holt Next generation maintenance with module-level monitoring - Module-level voltage shutdown for installer and firefighter safety { i USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA WWW.5olaredge.u5 Single Phase Inverters for North America solar=@to z SE3000A-US/SE3800A-US/SE500OA-US/SE600OA-US/ solar=@@ SE760OA-US/SE10000A-US/SE1140OA-US SolarEdge Single Phase Inverters -RU—TPUT 5200 @ 208V 9980 @ 208V 11520 VA Nominal AC Power Output 3300 3840 6000 7680 110080 @240V @240V For North America Max.AC Power Output 3650 4150 5600 @ 208V, ....6000 8350 10800 @ 208V 12000 VA 6000 @240V 10950 @240V SE300OA-US SE380OA-US/SE500OA-US/SE600OA-US AC Output Voltage Min.-Nom.-Max.* Vac SE760OA-USe SE1000OA-US ACOutput VoltagSE1140OA-US �-�24.0�-.26.4.vacMin�Nom.-Max.*­ ....... ............. ....... ......- ...... ...... ....... ........... AC Frequency Min.-Nam.-Max. ...... .......593-60-60.5(with HI country.setting 57-60-60.5) .. ................ @ 209V 25 L . 32 48 A Max,Continuous Output Current Hz 42 @ 244V 0Z -nt 14 16 I ........... .................. ............. ........... ........... .... Utility Monitoring,Islanding Protection,Country Configurable Yes _Thresholds RNe IMax,DC Power— commended PUT lie 4100 4800 J­1500-1--75— 12400 117 9600 1100 W Llan Transformer-less,Un rounded Yes K 325 @ 208V 350 @ 240V Vdc 35 Adc 3 Max.Input Current— 11 13 18 23 1 @ 240V 30.5 @ 240V .......... ......... ...... _1 ..Ma��.Input Short Circuit Current 30 45. ..... XclC ..... .......... ............ ...... Reverse-Palari ProtectionYesty ................. .......... .................... ........ .... ....... Ground-Fault Isolation Detection 600ka Sensith Ity 98 ..Maximurn Inverter Efficie ....... .......... 97 @ 208V 97.5 CEC Weighted Efficiency 97.5 98 9TS 97�5 % 98(CO 240V _5&240V 97.5 @ 20 8V ....�WPERTING Nighttime Power Co�Lsunjptlor� <2.588 2,5 ADDITIONAL FEATURES _T_f�MSupported Communication trite ng Deoarp rfaces RS485,RS232,Ethernet,Zfg8ee(optional) irtrry STANDARD COMPLIANCE Safety _U in U 199 CNN Rh'�­ L IEEE15 ........... ..... 7 Emissions FCC partly class 9 INSTALLATION SPECIFICATIONS It- r AC minimum 24-6 AW 4 AWd' �/4 3/4'minimum G 0 N1 A N CE output conduit sizef AWG 1. DC input conduit size/#of strings 3/e minimum 1-2 strings 24-6 AWG 3/4"minimum 1-2 st Dimensions with AC/DC Safety 30.5 x 12,5 x 7 30.5 x 12.5 x 7.5 in/ A, 30.5 x 12.5 x 10.5 775 x 315 x 260 775 x 315 x 191 .. mm ....... ..... 51.2/23,2 54.7/24.7 88,4/40,1 lb yyei ht with AC/DC Safety Switch J kg ....... ... ........ .. .......... ......... Cooling ..NattHa!Convection able) Noise <2dBA ..M:...­­­............................ .... ....... ........ ...... ....... ...... ...... in.-Max.Operating Temperature -13 to+140 -25 to+60(CAN version****-40 to+60) FPC The best th-oice ft)'r,,Sbiar-tdge.en,�abidd,system,s Rang Protection Rating NEMA 3R Integrated arc fault protection(Type 1)for NEC 2011690.11 complianceart numbers ending in"�-Un) ...... ........ ...... pa Superior,efficiency(98%) unrated to 225%for lo�atioras where the yeab,average high temperature is above 77sF/2PC and to 1a5%for locations where it is below 774F/252C. For detailed information,refer to . ............ Small,lightweight and easy to install on provided bracket A higher­nmt—may b...;the hatarter Will limit its input current to the values stated, CAN P/Ns are eligible for the Ontario FIT and mi=Frr(mi=FIT anx.SE114M-US-CAN) Built-in module-level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter,DC/AC conversion only Pre-assembled AC/DC Safety Switch for faster installation stuaa USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA ISRAEL AUSTRALIA www.solaredge.us