Loading...
14060163 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 7843 CREEKLINE DR CONTRACTOR:VRUSHAL DONGRE AND PERMIT NO: 14060163 ADRITA BHOR OWNER'S NAME: VRUSHAL DONGRE AND ADRITA BHOR 7843 CREEKLINE DR DATE ISSUED:06/25/2014 OWNER'S PHONE: 9499293289 CUPERTINO CA,CA 95014-4155 PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL E] COMMERCIAL E] * NO CONDITIONS License Class Lic.# Contractor Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$11500 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:36217042.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that i have read this application and state that the above information is PERMIT EXPIRES IF.WOR-K IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter WITHIN 18 SOF IT ISSUANCE OR upon the above mentioned property for inspection purposes. (We)agree to save 180 FRO ALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting ofthis permit. Additionally,the applicant understands and will comply wed- with all non-point source regulations per the Cupertino Municipal Code,Secti n 9.18. RE-ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. OWNER-BUILDER DECLARATION Signature of Applicant Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should 1 store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505, 33,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Owner or authorized agent: Date: R 1 certify that in the performance of the work for which this permit is issued,1 shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,1 CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must 1 hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date CONSTRUCTION PERMIT APPLICATION P COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION 10300 TORRE AVENUE• CUPERTINO, CA 95014-3255 `O (408) 777-3228• FAX(4C8)777-3333• build inpC5cupertino.org \ CUPERTINO �� ❑NEW CONSTRUCTION [:] ADDITION L1$ALTERATION/TI ❑ REVISION/DEFERRED ORIGINAL P/E�RMIT 4 PROJECT ADDRESS -7843 70 4 3 Cif-f ��I-I t 1. YQ, Cly 1 L KT)NCS APN 3 L Z / L v (/�^� OWNER NAME 'TU/I k l TA No, PHONE 1r,_I _ 2-q. 3ZSv_1 E-MAIL( m�t /� `� me;0.L ° W M STREET ADDRESS IS /�r� at ���u, r �n CITY, STATE,ZIP ����Z'� FAX CONTACT NAME AWTA Q,>j©/� G PHONE 61il `2 1 328 EMAIL ad9u 1��� YUA( � ' C�Jwc STREET.ADDRESS-7843 IZ E 1=1-Ll AJF CITY,STATE, ZIP C UD r QTI�NT `CA rC l FAX 11 OWNER tY OR1NER-BUILDER 11 OWNER AGENT ❑ CONTRACTOR ❑CONI-RACTORA11GENTT 13 ARCHITECT J❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS.LIC COMPANY NAME E-MAIL FAX STREET ADDRESS AV CITY,STATE,ZIP PHONE ARCHITECT/ENGINEER NAME AV /�►IT ( /��ttKNill el LICENSE NUMBER j [I BUS.LIC# COMPANY NAME ")TI (7' U h WG,R.10E E-MAIL ,/tF2CthTCT CT?\P it l (1'1C�mH1l FAX CW/h STREETADDRESSiL148 S S N�t CITY,STATE,ZIP PHONE C9,)-i �l3 DESCRIPT]ON OF WORK 6 dN VUCL-1T[Ncl �_E') 0 t N 1 IVC�r RCn (4) be 21 4 NIE-W ";t-Y L-1 Ll VIS C� �- r� �R mi L-1 Fvyv, AA N&)D V, a_ 6 U-0 LN l - I 1�0 i EXISTING USE PROPOSED USE CONSTR TYPE #STORIES .5F)?- G 1 j USE TYPE OCC. SQ.FT. VALUATION(S) EAREA G i [ NP.RI FLOOR DEMO *1 DRE 0 V TOTAL NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA d PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH I4 [G4C17ACH k DWELLING UNITS: IS A SECOND UNIT ❑YES SECOND STORY ❑YES i BEING ADDED? Md(r0 ADDITION? PRE-APPLICATION ❑YES IF YES,PROVIDE COPY OF IS THE BLDG AN ED B. - TOTAL V. TION: PLANTING APPL k ❑NO PL.ANTTLNG APPROVAL LETTER EICHLER HONIE? NO 00 By my sienature below,I ce tify to each of the follow I am the property o�NT r orized agent to ac t e pr owner's behalf. I have read this application and the information I have provided is c e t. ave read the Descri Ion of Work and veri I rate. I agree to comply with all applicable local ordinances and state laws relating to ui in_e list o , au epresentatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent: RKJ Date: SUPPLEMENTA7 ORS QUIRED PLAN CHECK TITE- R OUTLNGSISP, New SFD or Multifamily dwellings: Apply for demolition permit for ov Ex THECouN'TER ❑ BUILDII�c PLS.RE��Ew existing building(s). Demolition permit is required prior to issuance of building permit for new building. E' © PLAn�I�crLAn REVIEW _Commercial Bldgs : Provide a completed Hazardous Materials Disclosure (] sTA1`naxn ❑ PusLlewoRls form if any Hazardous Materials are being used as part of this project. [j URGE ❑ FIRE nEPT _Copy of Planning Approval Letter or Meeting with Planning prior to ❑ T'fAJOR �� ` ❑ SAI�ITARI'SEINER DISTRICT. submittal of Building Permit application. -:'ENI'IRONHIENTAL`HEALTH.` . B1dgApp_2011.doc revised 06/21/11 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 7843 CREEKLINE DR DATE: 06/25/2014 REVIEWED BY: MELISSA APN: 362 17 042 BP#: Io3 `VALUATION: 1$11,500 ^PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION 1 R3SFDREM USE: PERMIT TYPE: WORK CONVERT E 130 S.F. DINING RM TO IV BEDROOM WINDOW TO BE LOWERED/REPLACED SCOPE TO MEET EGRESS. INSTALL 4 (N) SKYLIGHTS IN FAMILY RM & 2 (N) SLINTUNNELS (HALL & Elec. Plan Check 0.0 hrs $0.00 Elec.Permit Fee: lEPERMIT E]__L_ Other Elec.Insp. 0.0 hrs $47.00 NOTE: This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc. . Thesefees are based on the prelimina information available and are only an estimate. Contact the Detor add 'I in o. FEE ITEMS (Fee Resolution 1FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 130 1 s.f. Remodel,Other Suppl. PC Fee: (F) Reg. 0 OT 0.0 hrs $0.00 $418.00 1REMRESOTH PME Plan Check: $0.00 1 # Skylight Permit Fee: $0.00 $418.00 1SKYtv0SF <= 10 s.f. Suppl. Insp. Fee:Q Reg. Q OT0.p 1 hrs $0.00 = Electrical PME Unit Fee: $0.00 $70.00 1 BMIFIAT Fixtures, Lighting PME Permit Fee: $47.00 Administrative Fee: 1ADMIN $44.00 Q Work Without Permit? 0 Yes (j) No $0.00 Advanced Plannin(y Fee: $0.00 Select a Non-Residential E) Travel Documentation Fee: ITRA VDOC $47.00 Building or Structure 0 i Strom Motion Fee: 1BSEISMICR $1.15 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $1.001 1 SUBTOTALS: $140.15 $906.00 TOTAL FEE: 1 $1,046.15 Revised. 04/01/2014 Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014-3255 Telephone: 408-777-3228 C U P E RT I N O Fax: 408-777-3333 CONTRACTOR/ SUBCONTRACTOR LIST JOB ADDRESS: `j GENE D1Z PERMIT# l OWNER'S NAME: - IDP,--(lk &40P, PHONE# q2-q, 32-Sq GENERAL CONTRACTOR: BUSINESS LICENSE# ADDRESS: CITY/ZIPCODE: *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Date Please check applicable subcontractors and complete the following information: SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring/Carpeting Linoleum/Wood Glass/ Glazing Heating Insulation Landscaping Lathing Masonry Painting/Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile S-,e- 2-QVF Owner/ ortrackLSJWature Dat X OWNER-BUILDER DISCLOSURE FORM COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 (408)777-3228• FAX(408)777-3333• building a--cupertino.org CUPERTINO Dear Property Owner(s): An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at: SITE ADDRESS .7g43 r`ii kLtMfC .DAPN �n 1 _ b,w z BP#� 0/(-3 OWNER NAME OWNER ADDRESS :bDRIT-ANE C�?f TI trio DESCRIPTION OF WORK: 40 We are providing you with an Owner-Builder Acknowledgment and Information Verification Form to make you aware of l b , your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner-Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION (DIRECTIONS:Please read and initial each statement below to signify you understand or verify this information.) R-D21. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner- Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. ,LL�QL2. I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. �3. 1 understand as an"Owner-Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. A•b'4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. �1,b.5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" understate and federal law. � 6. 1 understand if I am considered an"employer" under state and federal law, I must register with the state and federal government,withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. fkW7. I understand under California Contractors' State License Law, an Owner-Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. k8. 1 understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s)that result from any latent construction defects in the workmanship or materials. OwnerBuilderFonn 2010.doc revised 04/14/10 R9-):9. 1 understand I may obtain more information regarding my obligations as an"employer"from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800-321-CSLB (2752)or www.cslb.ca.gov for more information about licensed contractors. kt10. 1 am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the site address listed above. 1'j 11. 1 agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner-Builders as well as employers. b,R2 712. 1 agree to notify the issuer of this form immediately of any additions,deletions, or changes to any of the infarmation I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner-Builder and wish to hire Contractors,you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers'compensation insurance coverage. CONSTRUCTION LENDING AGENCY (DIRECTIONS:Please complete the following construction lending agency information.) I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097 Civ.) Lender Name: Lender Address: Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note:A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: AW Date: ------------------------------------------------------------------------------------------------------------------------------------------- (NOTE: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner-Builder). AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner,the execution of which I understand is my personal responsibility, I hereby authorize the following person(s)to act as my agent(s)to apply for, sign, and file the documents necessary to obtain an Owner-Builder Permit for my project. Scope of Construction Project(or Description of Work): Project Location or Address: Name of Authorized Agent: Tel No Address of Authorized Agent: I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note:A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: OwneYBuilderForm 2010.doc revised 04/14/10 BUILDING ENERGY ANALYSIS REPORT PROJECT: Dongre & Bhor Skylight Addition/Alteration 7843 Creekline Drive RECEIVED Cupertino, CA JUN 2 5 2014 Project Designer: BY Aditi Mukherjee - Architect 1448 S. Stelling Road Cupertino, CA (408) 455-3793 Report Prepared by: Jennifer Ferris CUPERTINO ACCURATE ENERG 3713 Laguna Way 9 . r ,�r Building DPA81'h11e11� Sacramento, CA 958E ' f Milt (916) 483-7313 � � } �NVIEv�:`::u utt GORE (;OMPLANCE 1 ray. Job Number: 'axe 214110 Date: 6/23/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report.This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft,LLC—www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number:3119 Run Code:201406-23T13:02:03 /D:214110 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary 10 HVAC System Heating and Cooling Loads Summary 13 EnergyPro 5.1 by EnergySoft Job Number: ID:214110 User Number:3119 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Dongre & Bhor Skylight Addition/Alteration ❑ Multi Family ® Existing+Addition/Alteration 6/23/2014 Project Address California Energy Climate Zone Total Cond. Floor Area Addition #of Stories 7843 Creekline Drive Cupertino I CA Climate Zone 04 1,901 0 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Wall Wood Framed R-11 1,246 Existing Door Opaque Door None 38 Existing Roof Wood Framed Attic R-19 1,864 Existing Slab Unheated Slab-on-Grade None 1,901 Perim=198' Existing FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidef ins Shades Status Front(E) 40.5 0.580 0.65 none none Bug Screen Existing Front(E) 6.1 0.550 0.67 none none Bug Screen Existing Left(S) 68.7 0.580 0.65 none none Bug Screen Existing Rear(lAq 47.9 0.580 0.65 none none Bug Screen Existing Right(N) 106.6 0.530 0.65 none none Bug Screen Existing Right(N) 44.8 0.580 0.65 none none Bug Screen Existing Skylight 11.7 0.840 0.67 none none None Existing Skylight 5.8 0.470 0.31 none none None New Skylight 5.8 0.470 0.31 none none None New Skylight 5.8 0.470 0.31 none none None New Skylight 5.8 0.470 0.31 none none None New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78%AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status HVAC Ducted Ducted Attic,Ceiling Ins,vented 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by Ene Soft User Number.3119 RunCode:201¢06-23T13:02.03 10:214110 Pae 3 of 13 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Dongre & Bhor Skylight Addition/Alteration ❑Multi Family m Existing+Addition/Alteration 6/23/2014 Project Address California Energy Climate Zone Total Cond. FloorAddition #of Stories Area 7843 Creekline Drive Cupertino CA Climate Zone 04 1,901 0 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features (see Part 2 of 5) Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Skylight 1.1 0.550 0.38 none none None New Skylight 1.1 0.550 0.38 none none None New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by EnergySoft User Number:3119 Run Code:201406-23T13:02:03 /D:214110 Pa e 4 of 13 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Dongre &Bhor Skylight Addition/Alteration ❑ Multi Family ® Existing+Addition/Alteration 1612312014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist.These items require special written justification and documentation,and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification,and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. EnergyPro 5.1 by EnergySoft User Number:3119 Run Code:201406-23T13:02:03 /D:214110 Pa e 5 of 13 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Dongre &Bhor Skylight Addition/Alteration ❑ Multi Family m Existing+Addition/Alteration 6/23/2014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kgtu/ft2- r Space Heating 28.74 29.06 -0.32 Space Cooling 14.18 13.49 0.69 Fans 7.35 7.20 0.15 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 50.27 49.75 0.52 Percent Better Than Standard: 1.0 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E)90 deg Ext.Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 372 47 Fuel Available at Site: Natural Gas (S) 400 69 Raised Floor Area: 0 (W 450 48 Slab on Grade Area: 1,901 (N) 376 151 Average Ceiling Height: 8.0 Roof 1,901 37 Fenestration Average U-Factor: 0.56 TOTAL: 352 Average SHGC: 0.65 Fenestration/CFA Ratio: 18.5 REMARKS 1. 1984-1991 Default Assumptions were used when calculating the existing house including dual non-metal default windows and doors. 2.New Skylight Additions.(2x) 14"Velux Suntunnels(Or Equal).Maximum U-Value=0.55/0.38;(4x)22'x 38"Fixed Velux Skylights(Or Equal). Maximum U-Value=0.47,Maximum SHGC=0.31 STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company ACCURATE ENERGY 3713 Laguna Way Jennifer Ferns 6232014 Address g y Name City/State/ZipCity/State/Zip Sacramento, CA 95864 Phone (916)483-7313 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) .✓' Company Aditi Mukhedee-Architect 1448 S.Stelling Road Ms.Aditi Mukhe ee Address 9 Name n 4�\ City/State/Zip Cupertino, CA Phone (408)455-3793 Signed License# Date Ene Pro 5.1 by EneraySoff User Number.3119 RunCode:201406-23T13:02:03 /D:214110 Page 6 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date Dongre & Bhor Skylight Addition/Alteration ❑ Multi Family 10 Existing+Addition/Alteration 6/23/2014 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 305 0.110 R-11 90 90 Existing 4.3.1-A2 Existing Door 20 0.500 None 90 90 Existing 4.5.1-A4 Existing Wall 150 0.110 R-11 180 90 Existing 4.3.1-A2 Existing Door 18 0.500 None 180 90 Existing 4.5.1-A4 Existing Wall 163 0.110 R-11 180 90 Existing 4.3.1-A2 Existing Wall 402 0.110 R-11 270 90 Existing 4.3.1-A2 Existing Wall 225 0.110 R-11 0 90 Existing 4.3.1-A2 Existing Roof 1,864 0.049 R-19 90 0 Existing 4.2.1-A4 Existing Slab 1,901 0.730 None 0 180 Existing 4.4.7-A1 Existing FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC2 Azm Status Glazing Type Location/Comments 1 Window 11.8 0.580 Default 0.65 Default 90 Existing Dual Non-Metal Default OP Existing 2 Window 17.3 0.580 Default 0.65 Default 90 Existing Dual Non-Metal Default OP Existing 3 Window 6.1 0.550 Default 0.67 Default 90 Existing Dual Non-Metal Default FX Existing 4 Window 11.4 0.580 Default 0.65 Default 90 Existing Dual Non-Metal Default OP Existing 5 Window 15.3 0.580 Default 0.65 Default 180 Existing Dual Non-Metal Default OP Existing 6 Window 15.3 0.580 Default 0.65 Default1270 Existing Dual Non-Metal Default OP Existing 7 Window 15.3 0.580 Default 0.65 DefaultExisting Dual Non-Metal Default OP Existing 8 Window 22.8 0.580 Default 0.65 DefaultExisting Dual Non-Metal Default OP Existing 9 Window 15.3 0.580 Default 0.65 DefaultExisting Dual Non-Metal Default OP Existing 10 Window 18.3 0.580 Default 0.65 DefaultExisting Dual Non-Metal Default OP Existing 11 Window 14.3 0.580 Default 0.65 DefaultExisting Dual Non-Metal Default OP Existing 12 Window 53.3 0.530 Default 0.65 Default 0 Existing Dual Non-Metal Default DR Existing 13 Window 22.4 0.580 Default 0.65 Default 0 Existing Dual Non-Metal Default OP Existing 14 Window 53.3 0.530Default 0.65 Default 0 Existing Dual Non-Metal Default DR Existing 15 Window 22.4 0.580 Default 0.65 Default 0 Existing Dual Non-Metal Default OP Existing 16 Skylight 11.7 0.840 Default 0.67 Default 1 901 Existing Dual Non-Metal Clear SKY Existing (1) LI-Factor Type: 116-A=Default Table from Standards,NFRC=Labeled Value 2 SHGC Type: 116-13=Default Table from Standards,NFRC=Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len H t I LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 1 1 15 Bug Screen 0.761 1 16 INone 1.001 1 EnergyPro 5.1 by Ener Soft User Number:3119 Run Code:2014-06-23T13:02:03 /D:214110 Pae 7 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date Dongre & Bhor Skylight Addition/Alteration ❑ Multi Family ❑ Existing+Addition/Alteration 6/23/2014 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC2 Azm Status Glazing Type Location/Comments 17 Skylight 5.8 0.470 NFRC 0.31 NFRC 90 New Velux SKY Existing 18 Skylight 5.8 0.470 NFRC 0.31 NFRC 90 New Velux SKY Existing 19 Skylight 5.8 0.470 NFRC 0.31 NFRC 90 New Velux SKY Existing 20 Skylight 5.8 0.470 NFRC 0.31 NFRC 90 New Velux SKY Existing 21 Skylight 1.1 0.550 NFRC 0.38 NFRC 90 New Velux Sun Tunnel Existing 22 Skylight 1.1 0.550 NFRC 0.38 NFRC 90 New Velux Sun Tunnel Existing (1) U-Factor Type: 116-A=Default Table from Standards,NFRC=Labeled Value 2 SHGC Type: 116-B=Default Table from Standards,NFRC=Labeled Value EXTERIOR SHADING DETAILS Window Ove hanq Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len H t LExt REA Dist Len H t Dist Len H t 17 None 1.00 18 None 1.00 19 None 1.00 20 None 1.00 21 None 1.00 22 INone 1.00 EnergyPro 5.1 by EnergySoft User Number.3119 Run Code:201406-23T13:02:03 ID:214110 Page 8 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name Building Type 0 Single Family ❑Addition Alone Date Dongre & Bhor Skylight Addition/Alteration ❑ Multi Family 0 Existing+Addition/Alteration 6/23/2014 BUILDING ZONE INFORMATION Floor Area System Name Zone Name New Existing Altered Removed Volume Year Built HVAC Existing 1,901 15,208 1986 Totals 1 +0 -1,9011- 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 Central Furnace 78%AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Duct Ducts System Name Heating Coolin Duct Location R-Value Tested? Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS Ext. Rated Tank Energy Standby Tank Input Cap. Factor Loss or Insul. R- S stem Name Qty. Type Distribution Btuh al or RE Pilot Value Status CEC Standard MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Hot Water Piping Length ftc 0 �o CO Pipe Pipe Insul. Control Qty. HP Plenum Outside Buried Q— System Name Length Diameter Thick. ❑ EnergjtPro 5.1 by Ener Soft User Number:3119 RunCode:201406-23T13:02:03 ID:214110 Page 9 of 13 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF-1 R Project Name Date Dongre & Bhor Skylight Addition/Alteration 6/23/2014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance(CF-1 R,CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk(*)below.This Mandatory Measures Summary shall be incorporated into the permit documents,and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary.Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products(except field-fabricated windows) have a label listing the certified U-Factor,certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111(a). 117:Exterior doors and windows are weather-stripped;all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(1):The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of§118(1)when the installation of a Cool Roof is specified on the CF-1 R Form. *§1 50 a :Minimum R-19 insulation in wood-frame ceiling orequivalent U-factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§1 50 c : Minimum R-13 insulation in wood-frame wall orequivalent U-factor. *§1 50 d :Minimum R-13 insulation in raised wood-frame floor orequivalent U-factor. 150(f):Air retarding wrap is tested, labeled,and installed according to ASTM El677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1):Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%;water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A:Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)l B:Masonry or factory-built fireplaces have a combustion outside air intake,which is at least six square inches in area and is equipped with a with a readily accessible,operable,and tight-fitting damper and or a combustion-air control device. §150(e)2:Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket,when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning,Water Heating and Plumbing System Measures: §110-§113:HVAC equipment, water heaters,showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5:Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release valve,backflow prevention, pump isolation valve,and recirculation loop connection requirements of§113(c)5. §115:Continuously burning pilot lights are prohibited for natural gas:fan-type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE,SMACNA or ACCA. 150 : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks,such as storage tanks or backup tanks for solar water-heating system,or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems,and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction,chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems>15 psi,meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture,equipment maintenance,and wind. §1 500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4:Solar water-heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro5.1 by EnergySoff User Number:3119 Run Code:201¢06-23T13.02:03 /D:214110 Page 10 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Dongre & Bhor Skylight Addition/Alteration 6/23/2014 §150(m)1:All air-distribution system ducts and plenums installed,are sealed and insulated to meet the requirements of CMC Sections 601,602,603,604,605 and Standard 6-5;supply-air and return-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space.Openings shall be sealed with mastic,tape or other duct-closure system that meets the applicable requirements of UL 181, UL 181 A,or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings rater than 1/4 inch,the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities,support platforms for air handlers,and plenums defined or constructed with materials other than sealed sheet metal,duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D:Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8:Gravity ventilating systems serving conditioned space have either automatic or readily accessible,manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture,equipment maintenance,and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10:Flexible ducts cannot have porous inner cores. §150(o):All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings.Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a):Any pool or spa heating system shall be certified to have:a thermal efficiency that complies with the Appliance Efficiency Regulations;an on-off switch mounted outside of the heater;a permanent weatherproof plate or card with operating instructions;and shall not use electric resistance heating ora pilot light. §114(b)1:Any pool or spa heating equipment shall be installed with at least 36"of pipe between filter and heater,or dedicated suction and return lines,or built-up connections for future solar heating. 114(b)2:Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water,and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing,flow rate, piping,filters, and valve requirements of§150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by§150(k)2. 150(k)3:The wattage of permanently installed luminaires shall be determined asspecified by§130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line- voltage lamp holder;OR shall be rated to consume no more than five watts of power as determined by§130(d), and shall not contain a medium screw-base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of§150(k). 150(k)7:All switching devices and controls shall meet the requirements of§150(k)7. §150(k)8:A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ftz or 100 watts for dwelling units larger than 2,500 ftz may be exempt from the 50%high efficacy requirement when:all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor,dimmer,energy management system(EMCS), or a multi-scene programmable control system;and all permanently installed luminaries in garages, laundry rooms,closets greater than 70 square feet,and utility rooms are high efficacy and controlled by a manual-on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number:3119 Run Code:201406-23713:02:03 /D:214110 Page 11 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-'I R Project Name Date Dongre & Bhor Skylight Addition/Alteration 6/23/2014 §150(k)10:Permanently installed luminaires in bathrooms,attached and detached garages,laundry rooms,closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of§119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual-on occupancy sensor. §150(k)11:Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms,garages, laundry rooms, closets,and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of§119,or by a manual- on occupant sensor that complies with the applicable requirements of§119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with§150 k 11. §150(k)12:Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact(IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory;and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283;and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13:Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies,and porches,which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch,a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls:a photocontrol not having an override or bypass switch that disables the photocontrol;OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock;OR an energy management control system(EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2:Outdoor luminaires used to comply with Exceptions to§150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool,water features,or other location subject to Article 680 of the California Electric Code need not be hi h efficacy luminaires. §150(k)14:Internally illuminated address signs shall comply with Section 148;OR not contain a screw-base socket, and consume no more than five watts of power as determined according to§130 d . §150(k)15:Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134,and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134,and 146. §150(k)16:Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoR User Number:3119 Run Code:201406-23T13:02:03 /D:214110 Page 12 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Dongre & Bhor Skylight Addition/Alteration 6/23/2014 System Name Floor Area HVAC 1,901 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 40,000 Total Room Loads 1,166 23,753 749 807 29,801 Total Output Btuh 40,000 Return Vented Lighting 0 Output Btuh/s ft 21.0 Return Air Ducts 1,313 2,036 Cooling S stem Return Fan o 0 Output per System 30,000 Ventilation 0 0 0 0 0 Total Output Btuh 30,000 Supply Fan 995 -995 Total Output ons 2.5 Supply Air Ducts 1,313 2,036 Total Output Btuh/s ft) 15.8 Total Output s ft/Ton 760.4 TOTAL SYSTEM LOAD 1 27,374 749 32,878 Air System CFM per System 1,000 HVAC EQUIPMENT SELECTION Airflow cfm 1,000 Existing Furnace-A/C 23,984 5,416 40,000 Airflow cfm/s ft 0.53 Airflow cfm/Ton 400.0 Outside Air % 0.0% Total Adjusted System Output 23,984 5,416 1 40,000 Outside Air(cfm/s ft) 0.00 (Adjusted for Peak Design conditions) Note:values above given at ARI conditions I TIME OF SYSTEM PEAK Aug 3 PM I Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 28 IF 68 OF 105 IF 106 OF t r' Outside Air 0 cfm Heating Coil Supply Fan 104 IF 1,000 cfm ROOD ',1'. 68 IF 70 IF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak) 88/68'F 79/64 OF 57/56 IF 58/56 OF Outside Air 0 cfm Cooling Coil Supply Fan 59/56 IF 1,000 cfm �a 44.5% ROOM i � 79/64 OF 78/63 OF A .4 EnergyPro 5.1 by EnergySoft User Number:3119 Run Code:201406-23713:02:03 /D:214110 Page 13 of 13