Loading...
B-2017-0728CITY OF CUPERTINO BUILDING PERMIT. BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-0728 10521 CASTINE AVE CUPERTINO, CA 95014-1310 (326 44 037) SOLARCITY CORPORATION SAN MATEO, CA 94402 OWNER'S NAME: HUANG SHAW HWA TRUSTEE DATE ISSUED: 05/08/2017 OWNER'S PHONE: 408-242-2762 PHONE NO: (650) 963-5100 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class C-10: C-46 Lic. #B33194 Contractor SOLARCITY CORPORATION Date 12/31/2018 X BLDG X ELECT — PLUMB MECH X RESIDENTIAL — COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing — with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: (N) 11-PANEL ROOF MOUNTED PV SYSTEM (3.25 KW); (I) CENTER I hereby affirm under penalty of perjury one of the following two declarations: PANEL (200 AMPS) 1. I have and will maintain a certificate of consent to self-insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the e ormance of the work for which this permit is issued. pe' A have and will maintain Worker's Compensation Insurance, as provided for by ryj Section 3700 of the Labor Code, for the performance of the work for which this Sq. Ft Floor Area: Valuation: $9000.00 permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above APN Number: Occupancy Type: information is correct. I agree to comply with all city and county ordinances 32644 037 326 and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the applicant understands and will comply with all non-point source regulations,per the Cupertino Municipal Code, Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. Signature Date 5/8/2017 Issued by: AbbyAvende DER DECLARATION Date: 05/08/2017 OWNER-BUff I hereby affirm that I am exempt from the Contractor's License Law for one of the RF.-ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is following two reasons: r. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed Signature of Applicant: contractors to construct the project (Sec.7044, Business & Professions Code). Date: 5/8/2017 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER u. I have and will maintain a Certificate of Consent to self-insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the permit is issued. s. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous shall not employ any person in any manner so as to become subject to the air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the Cuper ' o Municipal Code, Chapter 9.12 and exemption, I become subject to the Worker's Compensation provisions of the the Health &Safety Code, Sec ns25533, and 25534. Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. Owner or authorized agent APPLICANT CERTIFICATION Date: 5[$/2917 1 certify that I have read this application and state that the above information is CON TRUCTIO LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance correct. I agree to comply with all city and county ordinances and state laws of work's for which this permit is issued (Sec. 3097, Civ C.) relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, Lender's Address judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands R DECLARATION and will comply with all non-point source regulations per the Cupertino Municipal as public records. ua I understand my plans shal1l1 bbe e used Code, Section 9.18. Licensed Signature Date 5/8/2017 Professional CUPERTINO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 (408) 777-3228 - FAX (408) 777-3333 - bui(ding(ftugertno.org PROJECT ADDRESS / I / S % / J� G, jJ �O Q� kj t:::) r� APN #� OWNER NAME 6 14 J � W /4 -,)A,)4&— y PHONE �Q O� 2,14;-> %V -r;-> &MAA W f TO h VA �f ET MEADDRESS FAX CONTACT NAME Gerry Igtanloc PHONE650-759-8042 E-MAILgigtanloc@solarcity.com I STREET ADDRESS 391 Foster City Blvd. CITY, STATE, ZIP Foster City,CA,94404 FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACrOR NAME SolarCity Corp. LICHEN888104 LICENSE TYPE C10,C46 I BUS. LIC#28844 COMPANYNAMES'`olarCity Corp. E-MAILgigtanloc@solarcity.com FAX 111113055 Clearview Way CITY, STATE, ZIP can Mateo, CA 94402 �+ PHONE650-759-8042 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL f FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF ❑ SFD or Duplex ❑ Multi -Family STRUCTURE: ❑ Commercial PROJECT IN WILDLAND URBAN INTERFACE AREA ❑ Yes ❑ No PROJECT IN FLOOD ZONE ❑ Yes ❑ No N—LsoLAR PANELS I ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING±TOTATLVALUATIONO HER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: 1 KILOWATTS (COMMERCIAL ONLY): 00 0 DESCRIPTION OF WORK I 0 0 o Install( 1( ) rooftop mounted solar panels, (3 Z15 -Y KW RECEIVED BY: aaAGAtlW By my signature below, I certify to each of the llowing: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provid is correc I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to buildin nstru ti rize representatives of Cupertino to enter the ab� i ntifredpproperty for inspection purposes. Signature of Applicant/Agent: Date: SUPI'VEMENTAL INFORMATION REQUIRED OFFICE USE ONLY W U a ❑ OVERTHE-COUNTER ❑ EXPRESS ❑ STANDARD ❑ LARGE ❑ MAJOR PVApp 2011.doc revised 03/16/11 1461& DocuSign Envelope ID- B5460BCO-15CE-44F7-9455-B71BE13C9570 SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION CUPERTINO 10300TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buiiding@cuoertina ora Address 10521 Castine Avenue Cupertino, CA 95014 PURPOSE m This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi-family.dwellings shall be provided with Smoke AIarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section 8314 aid CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the follownig locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity -of the X X bedroom(g) On every Ievel of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office .of the State Fite Marshal. Power Supply- h1 dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the. removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.114 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building And California Residential Codes. The alarms have been tested and are operational, as of the date signed below !have rear! and agree to comely,with the terms and conditions of this statement Owner (or Owner AgenCs) Mame:oocusigned by: Shaw Huang �sr naturB...... r- Dates 5/ ..-&--- 4/2017 Ca�t ontror Name: o798BVE9568402. 5i nature.. .Lie.# . Date: Smoke and CCArin.doc revised 03118114 INDEX ABBREVIATIONS ELECTRICAL NOTES VICINITY MAP JURISDICTION NOTES REV BY DATE COMMENTS REV A NAME DATE COMMENTS * * * * * * * * * * * * * * * * LICENSE GENERAL NOTES Kim Dunbar 05/08/17 05/08/17 B-2017-0728 Kim Dunbar Front Of House 3' FSB3' FSB3' FSB 3' FSBA Pitch5/12MP1 Scale: 1/8" = 1' SITE PLAN 0 1' 8' 16' LEGEND MP1 19 270 19 270 Low Profile W-Tile 1 Story Kim Dunbar 05/08/17 S1 SIDE VIEW OF MP1 NTS X-SPACING PORTRAIT LANDSCAPE STORIES: ROOF AZI X-CANTILEVER Y-SPACING Y-CANTILEVER PITCH ARRAY AZI PITCH NOTES X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. MP1 270 19 270 19 Low Profile W-Tile - Skip Sheathing 12"x6" @ 24" OC 2"x6" @16" OC 72" 24" 48" 24" 48" 20" 24"48" RAFTER C.J. A Scale: 1 1/2" = 1' STANDOFFS1 Kim Dunbar 05/08/17 UPLIFT CALCULATIONS Kim Dunbar 05/08/17 LICENSEMODULE SPECS INV 1 INVERTER SPECS GENERAL NOTES MAIN PANEL SPECS GROUND SPECS INV 2 INV 3 AC DC N A B EGC/GEC GEC B V240 L2 L1 N EGC/ GEC GND N ADJUST MIN. ACTIVATION VOLTAGES! Inverter 1 PAR DC+ EGC DC- A EGC DC- DC+ MP1: 1x11 Vstart = 200V A B POI 1 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC1 2 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC2 3 Vmp = VAC Imp= AAC 3 4 Vmp = VAC Imp= AAC 4 Kim Dunbar 05/08/17 3055 Clearview Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)-SOL-CITY (765-2489) www.solarcity.com LB-130089-10X Per Code: CEC 690.31.G.3 Label Location: (C)(IC)(CB) LB-050081-10X Per Code: CEC 690.13.B Label Location: (DC) (INV) LB-030042-10X Per Code: CEC 690.53 Label Location: (DC) (INV) LB-070004-10X Per Code: CEC 690.5(C) Label Location: (INV) LB-050082-10X Per Code: CEC 690.13.B Label Location: (AC) (POI) LB-040007-10X Per Code: CEC 690.54 Label Location: (AC) (POI) LB-040013-10X Label Location: (AC) LB-070005-10X Per Code: CEC 690.17.E Label Location: (DC)(CB) LB-060046-10X Per Code: CEC 690.54; CEC 690.17 Label Location: (POI) LB_040108_10X Per Code: CEC 690.56(C) Label Location: (INV) LB-040009-10X Per Code: CEC 705.12.D.3 Label Location: (POI) LB-070039-10X Per Code: CEC 705.12.D.2.b Label Location: (POI) LB_200127_10X Per Code: CEC 705.12.D.2.c LB-070016-10X Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED Label Location: (DC)(INV)(CB) (POI): Point of Interconnection (M): Utility Meter (LC): Load Center (INV): Inverter With Integrated DC Disconnect (IC): Interior Run Conduit (DC): DC Disconnect (D): Distribution Panel (CB): Combiner Box (C): Conduit (AC): AC Disconnect Label Set Kim Dunbar 05/08/17 − − − − −  Z 8UVCTV  8 ű8 − − − − Kim Dunbar 05/08/17 5,00% 10,00% 15,00% 20,00% 25,00% 30,00% 35,00% 40,00% 45,00% 50,00% 55,00% 60,00% 65,00% 70,00% 75,00% 80,00% 85,00% 90,00% 95,00% 100,00% 215 250 300 345 400 480 [%] of Rated Power MPPT Voltage [V] 97,0 96,6 96 94,8 94,4 95,2 94 93,6 93,2 92,8 92,4 92 91,6 95,6 97,0 96,4 96,4 96 95,2 96 95,2 96,2 96 94 94 92 92 92 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 'HƂEKGPE QH 4CVGF 1WVRWV 2QYGT IN1 IN2 + - + - IN1 + - IN2 + - MPPT 2 (DC/DC) MPPT 1 (DC/DC) BULK CAPS INVERTER (DC/AC) LINE FILTER GRID PARALLEL RELAY L1 L2 PE RESIDUAL CURRENT DETECTION DC/DC DSP CONTR. DC/AC DSP CONTR. μP CONTROL CIRCUIT RS485 + T/R - T/R RTN REMOTE CONTROL* + R - R ALARM N.C N.O C GROUND FAULT DETECTION NIN1 IN2 + - + - DC AFDI IN1.1(+) IN1.2(+) IN1.1(-) IN1.2(-) IN1 IN2 + - + - IN2.1(+) IN2.2(+) IN2.1(-) IN2.2(-) IN1 IN2 + - + - WIRING BOX IN1 IN2 + - + - Kim Dunbar 05/08/17 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar’s sole warranty is contained in the written product warranty for HDFK SURGXFW 7KH HQGXVHU GRFXPHQWDWLRQ VKLSSHG ZLWK =HS 6RODU¶V SURGXFWV FRQVWLWXWHV WKH VROH VSHFL¿FDWLRQV UHIHUUHG WR LQ WKH SURGXFW ZDUUDQW\ 7KH FXVWRPHU LV VROHO\ UHVSRQVLEOH IRU YHULI\LQJ WKH VXLWDELOLW\ RI =HS6RODU¶V SURGXFWV IRU HDFK XVH 6SHFL¿FDWLRQV DUH VXEMHFW WR FKDQJH ZLWKRXW QRWLFH 3DWHQWV DQG $SSV ]VSDWVFRP Document # 800-1730-001 Rev A Date last exported: April 20, 2015 2:14 PM zepsolar.com Next-Level PV Mounting Technology ZS Span for concrete tile roofs Description • PV mounting solution for concrete tile roofs • Works with all Zep Compatible Modules • Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class “A” Fire Rating when installed using modules from DQ\ PDQXIDFWXUHU FHUWL¿HG DV ³7\SH ´ RU ³7\SH ´ 6SHFL¿FDWLRQV • Designed for pitch roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • =HS 6\VWHP JURXQGLQJ SURGXFWV DUH 8/ OLVWHG WR 8/  DQG (7/ OLVWHG WR 8/  • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72” and cantilevers up to 24” • =HS ZLUH PDQDJHPHQW SURGXFWV OLVWHG WR 8/  IRU ZLUH SRVLWLRQLQJ GHYLFHV • Attachment method UL listed to UL 2582 for Wind Driven Rain Document # 800-1730-001 Rev A Date last exported: April 20, 2015 2:14 PM This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar’s sole warranty is contained in the written product warranty for HDFK SURGXFW 7KH HQGXVHU GRFXPHQWDWLRQ VKLSSHG ZLWK =HS 6RODU¶V SURGXFWV FRQVWLWXWHV WKH VROH VSHFL¿FDWLRQV UHIHUUHG WR LQ WKH SURGXFW ZDUUDQW\ 7KH FXVWRPHU LV VROHO\ UHVSRQVLEOH IRU YHULI\LQJ WKH VXLWDELOLW\ RI =HS6RODU¶V SURGXFWV IRU HDFK XVH 6SHFL¿FDWLRQV DUH VXEMHFW WR FKDQJH ZLWKRXW QRWLFH 3DWHQWV DQG $SSV ]VSDWVFRP 1H[W/HYHO 39 0RXQWLQJ 7HFKQRORJ\ ]HSVRODUFRP Components 1x 3x 4x Spanner Bar Part Nos. 850-1400 - 4x 580-1399 - 3x 850-1398 - 1x Splice Kit Part No. 850-1401 Listed to UL 2703 Mighty Hook V2, HDG Part No. 850-1461 Listed to UL 2703 Interlock Part No. 850-1388 Listed to UL 2703 Cam Foot Part No. 850-1413 Listed to UL 2703 DC Wire Clip Part No. 850-1448 Listed to UL 1565 Array Skirt, Grip, End Caps Part Nos. 850-0113, 850-1421, 850-1460, 850-1467 Listed to UL 1565 Ground Zep Part No. 850-1172 ETL listed to UL 467 Spanner Clamp Part No. 850-1194 Listed to UL 2703 Kim Dunbar 05/08/17 ® ® ® ® Kim Dunbar 05/08/17 Mono Multi Solutions 18.0% MAXIMUM EFFICIENCY 270-295W POWER OUTPUT RANGE MODULE 60 CELL MONOCRYSTALLINE MODULE 0D[LPL]H OLPLWHG VSDFH ZLWK WRSHQG HIÀFLHQF\ • Up to 180 W/m² power density • /RZ WKHUPDO FRHIÀFLHQWV IRU JUHDWHU HQHUJ\ SURGXFWLRQ DW KLJK RSHUDWLQJ WHPSHUDWXUHV +LJKO\ UHOLDEOH GXH WR VWULQJHQW TXDOLW\ FRQWURO • 2YHU  LQKRXVH WHVWV 89 7& +) DQG PDQ\ PRUH • ,QKRXVH WHVWLQJ JRHV ZHOO EH\RQG FHUWLÀFDWLRQ UHTXLUHPHQWV •  (/ GRXEOH LQVSHFWLRQ THE &HUWLÀHG WR ZLWKVWDQG FKDOOHQJLQJ HQYLURQPHQWDO conditions • 2400 Pa wind load • 5400 Pa snow load • 35 mm hail stones at 97 km/h 0~+5W POSITIVE POWER TOLERANCE ĚĚŝƟŽŶĂů ǀĂůƵĞ ĨƌŽŵ dƌŝŶĂ ^ŽůĂƌ͛Ɛ ůŝŶĞĂƌ ǁĂƌƌĂŶƚLJ 'ƵĂƌĂŶƚĞĞĚ WŽǁĞƌ80% 90% 100% 97% <HDUV 5 10 15 20 25 $V D OHDGLQJ JOREDO PDQXIDFWXUHU RI QH[W JHQHUDWLRQ SKRWRYROWDLF SURGXFWV ZH EHOLHYH FORVH FRRSHUDWLRQ ZLWK RXU SDUWQHUV LV FULWLFDO WR VXFFHVV :LWK ORFDO SUHVHQFH DURXQG WKH JOREH 7ULQD LV DEOH WR SURYLGH H[FHSWLRQDO VHUYLFH WR HDFK FXVWRPHU LQ HDFK PDUNHW DQG VXSSOHPHQW RXU LQQRYDWLYH UHOLDEOH SURGXFWV ZLWK WKH EDFNLQJ RI 7ULQD DV D VWURQJ EDQNDEOH SDUWQHU :H DUH FRPPLWWHG WR EXLOGLQJ VWUDWHJLF PXWXDOO\ EHQHÀFLDO FROODERUDWLRQ ZLWK LQVWDOOHUV GHYHORSHUV GLVWULEXWRUV DQG RWKHU SDUWQHUV DV WKH EDFNERQH RI RXU VKDUHG VXFFHVV LQ GULYLQJ 6PDUW (QHUJ\ 7RJHWKHU 7ULQD 6RODU /LPLWHG ZZZWULQDVRODUFRP &RPSUHKHQVLYH SURGXFWV DQG V\VWHP FHUWLÀFDWHV • ,(&  ,(&  8/  ,(& ,(&  • ,62  4XDOLW\ 0DQDJHPHQW 6\VWHP • ,62  (QYLURQPHQWDO 0DQDJHPHQW 6\VWHP • ,62  *UHHQKRXVH *DVHV (PLVVLRQV 9HULÀFDWLRQ • 2+6$6  2FFXSDWLRQ +HDOWK DQG 6DIHW\ 0DQDJHPHQW 6\VWHP TSM_EN_2016_CCAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. ‹  7ULQD 6RODU /LPLWHG $OO ULJKWV UHVHUYHG 6SHFLÀFDWLRQV LQFOXGHG LQ WKLV GDWDVKHHW DUH VXEMHFW WR FKDQJH ZLWKRXW QRWLFH THE ELECTRICAL DATA (STC) Peak Power Watts-P0$; :S 270 275 280 285 290 295 3RZHU 2XWSXW 7ROHUDQFH30$; : 0~+5 0D[LPXP 3RZHU 9ROWDJH9033 9       0D[LPXP 3RZHU &XUUHQW,033 $       2SHQ &LUFXLW 9ROWDJH92& 9       6KRUW &LUFXLW &XUUHQW,6& $       0RGXOH (IÀFLHQF\ ¯m        67& ,UUDGLDQFH  :Pò &HOO 7HPSHUDWXUH ƒ& $LU 0DVV $0 7HVW WROHUDQFH “ PACKAGING CONFIGURATION 0RGXOHV SHU ER[  SLHFHV 0RGXOHV SHU · FRQWDLQHU  SLHFHV MAXIMUM RATINGS 2SHUDWLRQDO 7HPSHUDWXUH aƒ& 0D[LPXP 6\VWHP 9ROWDJH 9 '& ,(& 9 '& 8/ 0D[ 6HULHV )XVH 5DWLQJ 15A ELECTRICAL DATA (NOCT) 0D[LPXP 3RZHU30$; :S 201 205 209 212  220 0D[LPXP 3RZHU 9ROWDJH9033 9       0D[LPXP 3RZHU &XUUHQW,033 $       2SHQ &LUFXLW 9ROWDJH92& 9       6KRUW &LUFXLW &XUUHQW,6& $       12&7 ,UUDGLDQFH DW  :Pò $PELHQW 7HPSHUDWXUH ƒ& :LQG 6SHHG  PV TEMPERATURE RATINGS 1RPLQDO 2SHUDWLQJ &HOO 7HPSHUDWXUH 12&7ƒ&“ ƒ& 7HPSHUDWXUH &RHIÀFLHQW RI 30$; ƒ& 7HPSHUDWXUH &RHIÀFLHQW RI 92&  ƒ& 7HPSHUDWXUH &RHIÀFLHQW RI ,6& ƒ& WARRANTY  \HDU 3URGXFW :RUNPDQVKLS :DUUDQW\ 25 year Linear Power Warranty 3OHDVH UHIHU WR SURGXFW ZDUUDQW\ IRU GHWDLOV MECHANICAL DATA 6RODU &HOOV 0RQRFU\VWDOOLQH  ð  PP  LQFKHV &HOO 2ULHQWDWLRQ  FHOOV  ð  0RGXOH 'LPHQVLRQV  ð  ð  PP  [  [  LQFKHV :HLJKW  NJ  OE *ODVV  PP  LQFKHV +LJK 7UDQVPLVVLRQ $5 &RDWHG 7HPSHUHG *ODVV Backsheet :KLWH ''$  %ODFN ''$  )UDPH %ODFN ''$  ''$  J-Box ,3  RU ,3  UDWHG &DEOHV 3KRWRYROWDLF 7HFKQRORJ\ &DEOH PPò  LQFKHVò 1000 mm  LQFKHV &RQQHFWRU 0& )LUH 7\SH 7\SH  RU 7\SH  DIMENSIONS OF PV MODULE I-V CURVES OF PV MODULE(295W) unit:mm/inches MODULE PRODUCTS POWER RANGE 760''$  275-295W 760''$  270-290W P-V CURVES OF PV MODULE(295W)           ć          ˄ ˅Back View 180 9921650 AA 941180 990 3306-׎4.3 Grounding Hole 12-Drain Hole 1000 ±10Junction Box Nameplate 4- 9×12 Installing Hole A-A Kim Dunbar 05/08/17