B-2017-0153CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-0153
7662 SHADOWHI.LL LN CUPERTINO, CA 95014-5062 (362 24 022) T F F HEATING AND
AIR CONDITIONING
MILPITAS, CA 95035
NAME: CHEN WENHSING TRUSTEE & ET AL
DATE ISSUED: 01/26/2017
OWNER'S PHONE: 408-500-9245 IPHONENO: (408) 500-9245 1
t Is .1� tit t ._.; �♦
License Class C-20 Lic. #917350
Contractor T F F HEATING AND AIR CONDITIONING Date 06/30/2018
I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing
with Section 7000) of Division 3 of the Business & Professions Code and that my
license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
t. I have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
iformance of the work for which this permit is issued.
,, F I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above
information is correct. 1 agree to comply with all city and county ordinances
and state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above mentioned property for
inspection purposes. (We) agree to save indemnify and keep harmless the
City of Cupertino against liabilities, judgments, costs, and expenses which
may accrue against said City in consequence of the granting of.this permit.
Additionally, the applicant understands and will comply with all non -point
source regulations per the Cupertino Municipal Code, Section 9.18.
jJ.
Sianature '� �'�~�-y` __..[late 1/26/2017
I hereby affirm that I am exempt from the Contractor's License Law for one of the
following two reasons:
1. I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sce.7044, Business & Professions Code)
z. L as owner of the property, am exclusively contracting with licensed
contractors to construct the project (See.7044, Business & Professions Code).
hereby affirm under penalty of perjury one of the following three declarations:
L I have and will maintain a Certificate of Consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
z. I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
s. 1 certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the
Worker's Compensation laws of California. If, after making this certificate of
exemption, l become subject to the Worker's Compensation provisions of the
Labor Code, I must forthwith comply with such provisions or this permit sball
be deemed revoked.
APPI ICANT CERTIFICATION
certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws
relating to building construction, and hereby authorize representatives of this city
to enter upon the above mentioned property for inspection purposes. (We) agree
to save indemnify and keep harmless the City of Cupertino against liabilities,
judgments, costs, and expenses which may accrue against said City in
consequence of the granting of this permit. Additionally, the applicant understands
and will comply with all non -point source regulations per the Cupertino Municipal
Code, Section 9.18.
Signature Date 1/2512017
PERNM INFO:
BLDG —ELECT —PLUMB
MECH X RESIDENTIAL _ COMMERCIAL
JOB DESCRIPTION:
REPLACE FURNACE (SAME LOCATION)
Ft Floor Area: I Valuation: $2750.00
APN Number: Occupancy Type:
362 24 022
PERMIT EXPIRES IF WORK IS NOT STARTED
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
180 DAYS FROM LAST CALLED INSPECTION.
Issued by: Abby Aygnde
R& ROOFS•
All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
Signature of Applicant:
Date: 1/26/2017
ROOF COVERINGS TO BE CLASS "A"
HAZARDOUS MATERIALS DISCLOSURE
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
Health & Safety Code, Section 25532(a) should I store or handle hazardous
material. Additionally, should I use equipment or devices which emit hazardous
air contaminants as defined by the Bay Area Air Quality Management District I
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
the Health & Safety Code, Sections 25505, 25533, and 25534.
Owner or authorized agent: _ r----- c
Date: 1/261201.7
I hereby affirm that there is a construction lending agency for the performance
of work's for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
Lender's Address
ARCHITECT'S DECLARATION
I understand my plans shall be used as public records.
Licensed
Professional
GENERAL PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT ® BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • buildingCa�cupertino.orq
r7 M I TA41ITTITt'l `IIn,rr—.,.,T, 11 r-1.
MEP
misc
- liLGt
PROJECT ADDRESS b)- V/w s _ / !
�', ve,
lnLi,r-�L. ivubt- ,LLANEUUN _
APN # -3Q,2— 7-4 o 2
OWNER NAME ` , (� � A �� � „ ,l fl
/ V 1
PHONE v
� � � �
E MAII,
STREET ADDRESS n i
CITY, STATE, ZIP
FAX
pr
CONTACT NAMEQ`„pp y C
�t'I'1iL W-, is
PHONE
E-MAII
STREET ADDRESS
CITY, STATE, ZIP
FAX
❑ OWNER ❑ OWNER BUILDER ❑ OWNER AGENT ❑ CONTRACTOR . CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAME j�e'r, s �
- /
LICENSE NUMBER j oy
YD I
LICENSE TYPE /'��
BUS. LIC # J �j
#'
COMPANY NAME TF -P-#
E-MAIL �FF5_ v A-� A h a C0
V
FAX
STREET ADDRESS l �-
CITY, STATE, ZIP B` (, �,��� ^A IS -6 420
(� ( (s
pH0 D 2'Y
ARCHI TECT/ENGINEER NAME
LICENSE NUMBER
BUS_ LIC #
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
USE OF FwKFD or DUPLEX ❑ MULTI -FAMILY
BUILDING ❑ COMMERCIAL
PROJECT IN WI DLAND ❑ YES
URBAN INTERFACE AREA ❑ NO
PROJECT IN ❑ YES
FLOOD ZONE ❑ NO
IS THE BLDG AN ❑ YES
EICHLERHOME? ❑ NO
DESCRIPTION OF WORK c a ca -
TOTAL VALUATION:
By my my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf I have read this
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to build' g co ction. I authorize representatives of Cupertino to enter the above- entiified roperty for inspection purposes.
Signature of Applicant/Agent: Date: L 'T
SUPPLEMEN N REQUIRED
oI use olva�Y
v -.n
w
-- 'sTANI}apay
"ivrAaoi
MEPMiscApp 2011.doc revised 06/21/11
V
CERTIFICATE OF COMPLIANCE CFIR-ALT 02-E
Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 1 of 3)
Project Name: Wen-Hsing Chen Date Prepared: 2017-01-26
A. General Information
CFIR-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF1R-ALT-02 document for each dwelling unit.
01
Project Name
Wen-Hsing Chen
02
Date Prepared
2017-01-26
03
Project Location
7662 Shadowhill
04
Building Type
Single family
05
CA City
Cupertino
06
Dwelling Unit Name
Wen-Hsing Chen
07
Zip Code
95014
08
Dwelling Unit Conditioned
1760
Installing
Installing)
Installing
Floor Area (ft)
Location or Area
by this SC
ducted
F
system
Number of Space
entirely new
09
Climate Zone
4 '-`
10
Conditioning (SC) Systems in
1
component?
components?
feet of ducts?
duct system?
this Dwelling Unit:
Alteration Type
B. Space Conditioning (SC) System information
01
02
03
04
b5 `
06 `
07
08 "
09
10
lstheSC ;
Installing=a _
- '":•
-installing
SC System
SC System
CFA served
system a
refrigerant
new SC
Installing
Installing)
Installing
Identification or
Location or Area
by this SC
ducted
containing
system
more than 40
entirely new
entirely new
Name
Served
System (ft2)
system?
component?
components?
feet of ducts?
duct system?
SC system?
Alteration Type
System 1
Location 1
1760
Yes
No
Yes
No
No
No
Altered space
conditioning system
C. Extension of Existing Dud System, Greater Than 40 Feet (Section150.2(b)1Diib)
This section does not apply to this project.
Registration Number. 217 AO20016982A-000-000-0000000-0000 Registration Datefime: 2017-01-26 08:37:34 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-01-26 08:38:27
Schema Version: rev 10/16
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 2 of 3)
D. Altered Space Conditioning System (Sections 15O.2(b)1E and F)
01
02
03
04
05
06
07
08
09
10
11
12
Heating
Cooling
System
Heating
Altered
Heating
Minimum
Altered
Cooling
Minimum
Required
New or
Identification
System
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct
or Name
Type
Components
Type
Value
System Type
Components
Type
Value
Type
Duct Length
R -Value
All new
No cooling
This field ar
This field or
This field or
This field or
System 1
Central as
heating
AFUE
81
Central split
component
section is not
section is not
Setback
section is not
section is not
furnace
components
AC
altered
applicable
applicable
applicable
applicable
Required Documentation:
CF211-MCH-01-E-Space Conditioning Systems -.
- Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 iCZ 1-10,12 and 13) and R8 [CZ 11 and 14-161
CF2R and CFSR-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced
-Leakage rate compliance: r- 15% or <=10%leakage to outside; or seal all accessible leaks.
CF2R and CFSR-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
CF2R and CF311-MCH-23 Airflow Rate >= 300.CFM per'ton required when MCH:25 is required.
---.--
Exceptions: ..- `...--
- Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Dud Leakage Testing requirements
- Heating -only systems and Air Handler Furnace changes do not require verlficatiph'of Air Flow .MCH -23; or Refrigerant Charge MCH -25,
ceents.
-Existing duct systems constructed, insulated or sealed with asbestos are exernOFrom MCH=20 Dud Leakage Testing _reguim
E. Entirely New or Complete Replacement Duct System, with or witht E
ouquipment Changeout (Sections,150.2(b)1Dna and,1S0.2(b)1E, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 15O.2(b)1C)
This section does not apply to this project.
Registration Number. 217-A020016982A-000-000-OD00000-0000 Registration Date/Time: 2017-01-2608:37:34 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-01-26 08:38:27
Schema Version: rev 10/16
A
CERTIFICATE OF COMPLIANCE CFIR-ALT 02-E
Alterations to Space Conditioning Systems {formerly CF -IR -ALT HVAC} (Page 3 of 3)
Documentation Author's Declaration Statement
1.1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Ferreira, Tony
Company:
Signature Date:
T F F HEATING AND AIR CONDITIONING
2017-01-26 08:37:34
Address:
CEA/ HERS Certification Identification (if applicable):
299 CORNING AVENUE
City/State/Zip:
Phone:
M€LPITAS CA 95035
40&-786 8120
Responsible Person's Declaration statement'.
I certify the following under penalty of perjury, under the laws of. the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices forthe building design or system design identified on this Certificate of Compliance conform to the
requirements of7rde 24, Part 1 and Part hof the California Code of Regulations,
documents, worksheets,
4. The building design features or system designfeaturesidentifiedoAthisCertificateofCompliancearecansistentw�Yhtheinformationprovidedonotherapp_licableeompliance
calculations, plans and specifications submitted to the enforcement agency forapproval witfi this building permit application
S. I will ensure that a registered copy of this Certifccate of Compliance sha€f be'ma le apeifabte wish the byliding permits}.issued forrthe kruildIng, andmade avaitabte,to the enforcement agency for all applicable
Inspections. I understand that a registered copy of thisdertificate of Compl"iance,is;required to, cluded wth the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Re s anslbieDes€gnir5i n ature:
Ferreira, Tony
Company:
Date Signed:
T F F HEATING AND AIR CONDITIONING
2017-01-26 08:37:34
Address:
Ucense:
299 CORNING AVENUE
1917350
City(State/Zip:
Phone:
MILPITAS CA 95035
`108-786-8120
DigitallyagnedbyCaICERTS- This digitaisignatare is providedin order to secure the content ofthis registered document and in noway implies Registration Providerresponsibi6ry for the accuracyof the information.
Registration Number:217-A020016982A-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration Datel'rime: 2017-01-26 08:37:34
Report Version: 2016.1.005
Schema Version: rev 10/16
HERS Provider: CaICERTS
Report Generated: 2017-01-26 08:38:27
CUPERTINO
PURPOSE
SMOKE / CARBON MONOXIDE ALARMS
OWNER -CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING -DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • building (a)cupertino org
PF,R MT
COwIETEI>, 'i 1<.DtTLTRNFO THE B DIN --.1) FI
>
This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for
compliance with. 2016 CRC Section R314, R315, 2016 CBC Sections 420.6 and 907.2.11.2 where no interior access
for inspections are required.
GENERAL INFORMATION
Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon
Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds
$1000.00, CRC Section R314, R315, and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or
Carbon Monoxide Alarms be installed.in the following locations: -
AREA
SMOKE ALARM
CO ALARM
Outside of each separate sleeping area in the immediate vicinity of the
bedroom(s) — (Smoke alarms shall not be located within 3 feet of bathroom door)
X
X
On every level of a dwelling unit including basements and habitable -attics
X
X
Within each sleeping room _- : -.
X
Carbon Monoxide alarms are not required in dwellings which do not contain fuel-bun�uZg appliances and that
do not have an attached garage. Carbon monoxide alarms combined with: smoke alarms shall comply with
CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal.
Power Supply: In dwelling units with no commercial power supply, alarms) may be, solely battery operated.
Iri existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do
not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl
space. Refer to CRC Section R314 and CSC Sections 907.2.11.4•and 420.6.2. An electrical permit is required for
alarms which must be connected to the building wiring.
As owner of the above -referenced property, I hereby certify that the_alarm(s) referenced above has/have beezi
installed in accordance with the manufacturer's instructions and in compliance with the California Building
and California Residential Codes. The alarms specified below have been tested and are operational, as of the
date signed below. p
Address:b" _'_? -> k4owl"I�J
Z
f"i4)W
o' m Permit No. � � C51 � � 0 j
n
Specify Number of Alarms: # Smoke Alarms: �, # Carbon Monoxide Detectors: !�
l have read and aaree to comply with the terms »nrl ronn';tinn.c r7f thbz .QPatPm,-r)f
Owner (or Owner Agent's) Name:
_e _e.-•=
Signature.................................................................................................................. Date:..................
Contractor Name:
Signature... ........................... ................................... Lic.# .............. _....................... Date: ..................
Smoke and COfo7-177.doc revised 01/1012017
Owner Name
Address
1 01.
I z
[OITJTI il 1:3 -.491:4 -.AV I a LOLAN I :K#] a @to
_ jilij:11100
ffiffiEmi
COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION
10300 TORRE AVENUE - CUPERTINO, CA 95014-3255
(408) 777-3228 - FAX (408) 777-3333 - bujIdjnq(@cupertino.oLq Z -O/
—W ��Iv\ r- � I ?,A- Permit No,
1. Is your real property a registered historical site?
1-1 )'es Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
VNo Go to Question 2.
2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its
plumbing, installation of water -conserving plumbing fixtures is not technically feasible?
0 Yes Civil Code Sections 1101.1 through 1101.8 donot apply.
El The licensed plumber's certification has been provided to the Building Division.
Skip the rest of the form and sign bottom of form.
M No Go to Question 3.
3. Is water service permanently disconnected for your building?
0 Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
IV No Go to Question 4.
4. Is your real property built and available for use or occupancy on or before January 1, 1994?
0 No My real property is built and available for use or occupancy after January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
Yes My real property is built and available for use or occupancy on or before January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign
bottom of form..
5. Please check ONE of the following:
V1 My property is a single-family residential real property. See Civil Code Section 1101.4.
On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures
to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-
compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether
property undergoes alterations or improvements).
El My property is a multifamily residential real property. 'See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water -
conserving plumbing fixtures throughout the building (regardless of whetherpropertyundergoes alterations or,
improvements).
0 My property is a commercial real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving
plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements).
1, as the owner or owner's agent of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be
replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1
through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's
installation requirements, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the
table on the following page.
Owner or Owner Agent's Signature:
Date:
I Unnn n.nmnletinpr and signinLr this Certificate, Wease return it to the Building Division in order to final your building permit.
SB4072015.doc revised 08126115
TH the existing plumbing fixture water usage/flog rate is equal to or lower than the figure shown, Lis not require o , .1,
SB4072015.doc revised 08126115
Non -Compliant
I Water -Conserving Plumbing Fixture
Plumbing Fixture 1
(Fixture Complying with Current Code Applicable to New Construction)
Maximum
Water Usage/Flow
Rate
Fixture Type
Water Usage
2013 CPC Ch. 4
2013 CPQ Ch. 4
2013 CPC Ch. 4
2013 CALGreen Div. 4.3
2013 CALGreen Div. 4.3
2013 CALGreen Div. 5.3
/Flow Rate
Single -Family
Multi -Family
Commercial
Residential
Residential
Water Closets
Exceed 1.6
Single flush toilets: 1.28 gallons/flush
(Toilets)
Gallons/flush
Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite,
average flush volume of two reduced flushes and one full flush)
Urinals
Exceed 1.0
0.5, gallons/flush
Gallons/flush
Showerheads
Exceed 2.5
2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of
gallons per minute
U.S. EPA W, aterSense Specification for Showerheads
(A hand-held shower is considered a showerhead.)
For multiple showerheads serving one shower, the combined flow rate of all
Showerheads and/or other shower outlets controlled by -a single valve shall not
exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to
allow only one shower outlet to be in operation at a time.
Faucets —
Exceed 2.2 gallons
Maximum 11.5 gallons per
Within units:
0.5 gallons per minute @ 60
Lavatory
per minute
minute @ 6 ' 0 psi; minimum
Maximum 1.5 gallons
psi
Faucets
0.8 gallons Per minute @
per minute @ 60 psi;
20 psi
minimum 0.8 gallons
per minute @ 20 psi
In common and public
use areas: .0.5 gallons
per minute @ 60 psi
1.8 gallons per minute
@ 60 psi
Faucets —
—Exceed 2.2 gallons
1.8 gallons per minute @
1.8 gallons per minute
1.8 gallons per minute @ 60
Kitchen
per minute
60 psi
@ 60 psi
psi
Faucets
May temporarily increase,
May temporarily
up to 2.2 gallons per
increase up to 2.2
minute @ 60 psi, and must
gallons per minute @
default to maximum
60 psi, and must
1.8 gallons per minute @
default to maximum
60 psi
1.8 gallons per minute
Where faucets meeting
@ 60 psi
the above are unavailable,
Where faucets meeting
aerators or other means
the above are
may be used to achieve
unavailable, aerators or
reduction.
other means may be
used to achieve
reduction.
A+ b —1-1
TH the existing plumbing fixture water usage/flog rate is equal to or lower than the figure shown, Lis not require o , .1,
SB4072015.doc revised 08126115