B-2016-3210CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-3210 10325 DEMPSTERAVE CUPERTINO, CA 95014-1222 (326 47 081) WILLOW GLEN ELECTRIC INC SAN JOSE, CA 95155 OWNER'S NAME: CHANG PETER C AND MAI H _ DATE ISSUED: 12/05/2016 OWNER'S PHONE: 510-825-3261 PHONE NO: (408) 289-9725 LICENSED CONTRACTOR'SDECLARATION BUILDING PERMIT INFO: License Class C110 Lic. #591918 Contractor WILLOW GLEN ELECTRIC INC Date 04/30/2018 X BLDG —ELECT —PLUMB I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing MECH X RESIDENTIAL COMMERCIAL — — — with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: (N) EV OUTLET/ CHARGER IN GARAGE�. I hereby affirm under penalty of perjury one of the following two declarations: i. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the ` � ;performance of the work for which this permit is issued. W W 2. % I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this Sq. Ft Floor Area: Valuation: $1990.00 permit is issued. APPLICANT CERTIFICATION certify: that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction, and hereby authorize 326 47 081 representatives of this city to enter uponthe above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the applicant understands and will comply with all non -point source regulations p r tVeepertino Municipal Code, Section 9.18. 180 DAYS FR CTION. Signature_'_�(r Date 12/05/2016 Issued by: AN OWNER -BUILDER DECLARATION' Date: 12/05/2016 I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is 1. L as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed Signature of Applicant: contractors to construct the project (Sec.7044, Business & Professions Code). Date: 12/05/2016 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER s. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the s. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous shall not employ any person in any manner so as to become subject to the air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and exemption, I become subject to the Worker's Compensation provisions of the the Health & Safety Code, Sectiti/ons 5 , 25533, and 25534. Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. Owner or authorized agent ' APPLICANT CERTIFICATION Date: 12/05/2016 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws . CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance relating to building construction, and hereby authorize representatives of this city of work's for which this permit is issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name , to save indemnify and keep harmless the City of Cdperti!o 4against liabilities, judgments, costs, and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code, Section 9.18. 1 understand my plans shall be used as public records. Licensed Signature Date 12/05/2016 Professional V ALTERNATIVE ENERGY PERMIT APPLICATION _COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 10300 TORRE AVENUE CUPERTINO, CA 95014.3255 ClJr PERTI43 (408) 777-3228 + FAx (408) 777.3333 • build'- a 1011 � . r14 PROJECT ADDRESS O(, ,_ %l eg 1 �1 B (PH. APN # rJ / q / g ('j17 `i (i OWNERNAME -� 1 A A_t, �a'r1d ONE Sl E-MAIL STREET ADDRESS�g ®may may{J I•/] g .,,�yy" _ V {'� J/'C f''�l./"'3 • / V�`o : C/ITyY,,, STATE-,�Z}IP /� (r+'3^� p te.dG K./W4' O'i :. -!. ,� C�'/ FAX CONTACT NAMEPHONE Mark Londre (408)289-9725 E-MAIL office@willowgi nelectric.com STREET ADDRESS ry_ O, Box 8430, f CITY, STATE, ZIP San Jose, CA 95155 FAx (408)289-9725 OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT /CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME Mark Londre LICENSE NUMBER 59191ilp LICENSE TYPE-10 BUS. LIC# 15897 COMPANY NAME Willow Glen Electric, Inc. E-MAIL office@willowglenelectric.com FAX (408)289-9725 STREET ADDRESSP. O. Box 8430 CITY,STATE,ZIP San Jose,CA 95155 PHONE (408)289-9725 ARCHITECT/ENGINEERNAME N/A LICENSENUMBER BUS. LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF STD Or Duplex ❑ Multi -Family STRUCTURE: ❑ Commercial PROJECT IN WILDLAND URBAN INTERFACE AREA ❑ Yes ❑ NO PROJECT IN FLOOD ZONE O Yes 11 NO ❑ SOLAR PANELS 1!►J ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS. NUMBER OF PANELSLUNITS: KILOWATTS (COMMERCIAL ONLY): TOTAL VALUATION: DESCRIPTION OF WORK - Electric Vehicle Char in Circuit: i- " i M V yjr 2, j� /A.) - C,6Wa, 6-�-, 11-4-0 / �--� By my signature below,. I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I havje ad th escription of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building co t '} u% tives o£ Cupertinoto enter the above -identified property for inspection purposes.. Signature of Applicant/Agent: t► Date: ED SUPPLEMENTAL INFORMATION REQUIRED � le4 ,�%/ � OFFICE 075E QPl�'Y`' �- Qw,OVER COUNTER -"� EXR12ES3 . a , ❑� STt�NpARD LA" E' CI IKArox PVApp_2011.doc revised 03116111 DocuSign Envelope ID: 86EA3B3B-6994-4F04-88B0-18B1DA5995D1 ° � - Ila gifi=* SMOKE / CARBON .MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY. DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 (408) 777-3228. • FAX (408) 777-3333L. buiiding(a)-cupertino:orcl Permit No. B-2016- 3210 Address 10325 Dempster Avenue # of Alarms Smoke: 7 Carbon Monoxide: 8 PERIVIIT CANNOT BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE HAS BEEN SI,GNEg AND $ I1RNSD TO THE BUILDING DWISION PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to .existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms, and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X. X On every level of a dwelling unit including basements X X Within eacft.sleeping room J X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke..alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: in dwelling units with no- commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by, means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. I have read and aaree to comoiv with the terms .and conditions of this statement Owner (or Owner Agents) Name: DocuSigned by: Mai Chan si natur ..Al. Date12�12�2 .................................. Contractor Name: 2824AED48D5F4EB... Signature ........................... . Lic.# ..................... ...... Date:, Snwke and CO fonn.doc revised 03118114 16 WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 (408) 777-3228 - FAX (408) 777-3333 - building@cupertino.org Owner Name -Mai Chang Permit ......................................... No 0. B_2016_3210 Address 10325 Dempster Avenue, Cupertino, CA 95014 PERMIT CANNOT BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE HAS BEEN&UNED AND REUM= TO THE BUILDING DIVISION Please refer to the attached California Civil Code Sections 1101,1 1101.8 1101.8 which are part of this Certification form. I. Is your real property a registered historical site? E:1 Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: D Signed by: 12/12/2016 V�110 Go to Question 2. Date: E 2824AED48D5F4EB... 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? 0 Yes Civil Code Sections 1101.1 through 1101.8 do not apply. 0 The licensed plumber's certification has been provided to the Building Division. Sign below and skip the rest of the form. DocuSigned by: Owner' Signature:Date: 12/12/2016 M/�Io Go to Question 3. - E,2824AED48D5F4EB 3. Is water service permanently disconnected for your building?. El Yes Civil Code Sections 1101.I through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature:D CUSigned by: Date: 12/12/2016 No Go to Question 4. E 2824AED48D5F4EB.,. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? El No My real property is built and available for use or occupancy After January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Do uSigned by: Owner' Signature: - 6"" Date: 12/12/2016 a-fc-s My real property i(:' oble for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached. 0 My property is a shigle-famili, residential real property. See Civil Code Section 1101.4. On and after January 1. 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifbmitt= residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). F1 My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. .58407 2015.doc revised 02104115 RocuSign Envelope ID: 86EA3636-6994-41704-8860-18B1DA5995DI On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I/We, the owner(s) of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements. and that the water-conservir&u 'liafte fixtures comply with the requirements as indicated in the table below. Owner's (or Owner Agent's) Signature] IKJu (.LA Date:"/ y`/ "Wyw Upon completing and signing this Certificate, please return it to the Building Division in order to final your permit. 1. If the existing plumbing fixture water usage/flow rate is equal to or tower than the figure shown, it is not requircu lu oc upsmuuu. SB407 2015.doc revised 02/04/15 Non -Compliant Water -Conserving Plumbing Fixture Plumbing Fixturel (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type Water Usage 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 /Flow Rate J 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single -Family Multi -Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 0.5 gallons/flush Gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage/flow rate is equal to or tower than the figure shown, it is not requircu lu oc upsmuuu. SB407 2015.doc revised 02/04/15 Install one 240 Volt 30 Amp dedicated circuit with a surface -mounted NEMA 14-30 receptacle on the left of the garage in the owner - specified location for EV charging. This circuit will provide 24 continuous amps for charging. Surface -mounted 3/4" EMT with #10 THWN conductors/ground will be used to route the circuit from above the garage sub panel to the new NEMA 14-30 receptacle location. (Note: Garage dimensions are a minimum of 20'x20') Mai Chang 10325 Dempster Ave. Cupertino CA 95014 (510) 825-3261 House COMMUNITY DEVELOPMENT DgPARTMENT BUILDING DIVISION — CUP RTINO U APPROVE siT�t �t �dlbnpV &gfi�ations MUST be ept at the job e ourmg construction. It11isLnlawful to make a iy changes or /a&94 kaeno(fiaiate therefrom, wi hout approval 3/4" EMT w/ from the Building Official. #10 THWN conductors ALL NOT be s held to per it or to be an approval of the viol tion of any #10 THWN ground (N) provision of any City Ordinance or Stat Law. By Melissa Names DATE 12/05/16 PERMIT NO B-2016-3210 Garage 9P NEMA 14-30 Receptacle (N) CUPERTIN Building Departm nt REVIEWED FOR CODE COMPLIANCE Reviewed By: Melissa Names Date: 12/05/16 Mai Chang Page I 125A Main Panel (E) Driveway Take -off / Estimate Site Location: Prepared by Mai Chang I L L O W Willow Glen Electric, Inc. 10325 Dempster Ave. LEN PO Box 8430 Cupertino CA 95014 L E C T R I C San Jose, CA 95155 (510) 825-3261 �f (408) 289-9725 - office - Estimated By: MJL Description of Work Material Pricing Quantity Price Each Total Hourly Rate $ Labor Pricing Hours 120.00 Cost Unit Pricing NEMA 14-30 w/30A circuit in middle of left wall as $ 240.00 Travel /Lost Time 0.5 $ 60.00 $ 60.00 Load Calc, Engineering requested. Conduit from garage sub panel. 1 $ 120.00 $ 120.00 30A Murray breaker 1 $ 10.00 $ 10.00 0.25 $ 30.00 $ 44.88 3/4" rigid tight 90 etc. 1 $ 5.00 $ 5.00 0.25 $ 30.00 $ 37.44 3/4" AL LB w gasket, cover 1 $ 10.00 $ 10.00 0.25 $ 30.00 $ 44.88 3/4" EMT connector -screw 2 $ 1.00 $ 2.00 0.25 $ 30.00 $ 32.98 3/4" EMT 3 $ 5.00 $ 15.00 1 $ 120.00 $ 142.31 3/4" EMT coupling - screw 2 $ 1.00 $ 2.00 0.25 $ 30.00 $ 32.98 3/4" EMT straps 5 $ 1.00 $ 5.00 0.25 $ 30.00 $ 37.44 #10 THHN red, black, white, green 30 $ 1.00 $ 30.00 0.5 $ 60.00 $ 104.63 deep 4 11/16 box 1 $ 4.00 $ 4.00 0.25 $ 30.00 $ 35.95 NEMA 14-30 receptacle 1 $ 10.00 $ 10.00 0.25 $ 30.00 $ 44.88 411/16 raised metal cover 1 $ 3.00 $ 3.00 0.25 $ 30.00 $ 34.46 orange hook 1 $ 7.00 $ 7.00 0.25 $ 30.00 $ 40.41 NEMA 14-30 adapter- WGE 1 $ 45.00 $ 45.00 $ - $ 66.94 OPTIONAL TRANSFER SWITCH FOR SOA NEMA 14-50- 50A Murray breaker 1 $ 10.00 $ 10.00 0.25 $ 30.00 $ 44.88 6/3 Romex 6 $ 2.00 $ 12.00 0.5 $ 60.00 $ 77.85 Transfer Switch 1 $ 350.00 $ 350.00 1 $ 120.00 $ 640.63 3/4" offset connector 1 $ 2.00 $ 2.00 0.25 $ 30.00 $ 32.98 2 space Homeline indoor surface -mount sub panel 1 $ 20.00 $ 20.00 0.5 $ 60.00 $ 89.75 40A Homeline breaker 1 $ 10.00 $ 10.00 0.25 $ 30.00 $ 44.88 3/4" EMT connector -screw 2 $ 1.00 $ 2.00 0.25 $ 30.00 $ 32.98 3/4" EMT 3 $ 5.00 $ 15.00 1 $ 120.00 $ 142.31 3/4" EMT coupling - screw 2 $ 1.00 $ 2.00 0.25 $ 30.00 $ 32.98 3/4" EMT straps 5 $ 1.00 $ 5.00 0.25 $ 30.00 $ 37.44 #6 THHN Red, black, white, #10 THHN green 30 $ 2.00 $ 60.00 0.5 $ 60.00 $ 149.25 deep 4 11/16 box 1 $ 4.00 $ 4.00 0.25 $ 30.00 $ 35.95 NEMA 14-50 receptacle 1 $ 10.00 $ 10.00 0.5 $ 60.00 $ 74.88 411/16 raised metal cover 1 $ 3.00 $ 3.00 0.25 $ 30.00 $ 34.46 orange hook 1 $ 7.00 $ 7.00 0.25 $ 30.00 $ 40.41 8/3 Romex 5 $ 1.40 $ 7.00 0.5 $ 60.00 $ 70.41 #6 Ilsco splicers 2 $ 15.00 $ 30.00 0.25 $ 30.00 $ 74.63 $ 697.00 11.0 Tax 8.75% $ 60.99 Markup 40% $ 278.80 $ 1,036.79 11.0 $ 1,320.00 $ 2,356.79 Additional Expenses At Cost Hours Cupertino Permit $ 150.00 1 $ 120.00 $ 270.00 Stand In For Inspection 2 $ 240.00 $ 240.00 Travel /Lost Time 0.5 $ 60.00 $ 60.00 Load Calc, Engineering 1 $ 120.00 $ 120.00 $ 690.00 TOTAL $ 3,046.79 CUPERTINO $ 1,390.00 Building Department REVIEWED FOR CODE COMPLIANCE Reviewed By: Melissa Names Date: 12/05/16 INSTALLING AN ALTERNATIVE 244 VOLT OUTLET A 240 volt 30 amp rated outlet can be installed as an alternative to the NEMA 14-50 outlet for home charging. Called a NEMA 14-30, this outlet is commonly used for newer electric dryers. To utilize this outlet, purchase the NEMA 14-30 adapter from the Tesla website. The NEMA 14-30 outlet is best installed in situations where the electrical system cannot accommodate the power demands of the NEMA 14-50 outlet. This outlet will provide a maximum of 24 amps to the vehicle, resulting in recharge speeds of about 17 miles per hour for Model S and about 15 miles per hour for Model X. Typically, this recharge rate is more than enough to top off the battery overnight. Like most home improvement projects involving your electrical system, a local permit and inspection may be required. GROUND TO TOP 0 250 v NEMA 14-34 DETAILS t. . Voltage: Single phase, 208-250 volt AC supply, 60 hertz . Circuit Breaker: 30 amp (125% overcurrent protection) . Operating Current: 24 amp (maximum continuous current) . Conductors: 10 AWG, Copper Wire Only. Upsize wiring for installations over 150 feet . Ground Fault Circuit Interrupter: Not required • Service Disconnect: Not required . Receptacle Recommendation: High quality, industrial grade receptacle Examples: Hubbell part # HBL9430A, Cooper part #5744N . Ventilation: Not required . Outdoors: Install with NEMA 3R rainproof enclosure RECOMMENDED LOCATIONS ADDITIONAL RESOURCES EMAIL CHARGI NGI NSTALLATI ON@TESLA.COM PHONE 650.681.6133 (M -F) 24/7 TECH SUPPORT 877.798.3752 WEB TESLA.COM/SUPPORT CHARGE PORT CUPIES�TMTORE 13uiIdingD6-0KT i6hf0M RECOMMENDED LOCATION FOR 240 ET RFVIEWEC�-FOR CODE COMPLIANCE Reviewed By: Melissa Names T = 5 L n Date: 12/05/16 45500 Fremont Boulevard, Fremont, CA 94538 1 May, 2016 1 Version 3