Loading...
B-2016-1982CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-1982 20888 FARGO DR CUPERTINO, CA 95014-1806 (326 30 116) SUNRUN INSTALLATION SERVICES INC SAN LUIS OBISPO, CA 93401 OWNER'S NAME: LIU YOUZHONG AND ZHAO WEIYING DATE ISSUED: 05/19/2016 OWNER'S PHONE: 408-462-1188 PHONE NO: (888) 657-6527 LICENSED CONTRACTOR'S DECLARATION License Class C-46 Lic. #750184 Contractor SUNRUN INSTALLATION SERVICES INC Date 06/30/2016 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ,I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature d thDate 5/19/2016 BUILDING PERMIT INFO: X BLDG —ELECT —PLUMB _ MECH X RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION: (I) 25-PANEL ROOF -MOUNTED PV SYSTEM (6.0 KW) Sq. Ft Floor Area: I Valuation: $12300.00 "N Number: Occupancy Type: 32630 116 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLUD ,i S-PECTION. Issued by: Alex Vallelunea Date: 05/19/2016 I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is 1. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature ofApl Date: 5/19/2016 ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505, 25533, and 25534. Owner or authorized agent: Date: 5/19/2016 CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Signature Licensed Date 5/19/2016 CUPERTINO AI COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 •FAX (408) 777-3333 • building (a)cupertino.org iPs 20! C� PROJECT ADDRESS 0 2 � `3� � � r` jl J � p �� � � APN # OWNER NAME ��•V6�_"o' Nt & Lj U 1 Ci1� PHONE LW b7 1�/�_� E-MAIL STREET AD e v ��O Y ®• TY STATE,ZIP�J � FAX CONTACT NAME � ;�„ E-MAIL i � V STRfxgT FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NA �- !� . L I� LICFrE ICE BUS. LTC # / / COMPANY E, , 1Y ,�,, 411 •► o� 2 ARCHITECT/ENGINEF.R NAME LICENSE NUMBER BUS. LTC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF SFD Or Duplex ❑ Multi -Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ NO FLOOD ZONE ❑ Yes ❑ No SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION 1 ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS. NUMBER OF PANELS/UNITS: KILOWATTS (COMMERCIAL ONLY): r� TOTAL VALUATION: DESCRIPTION OF WORK By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read it Ii S application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above -id fified roperty for inspection purposes. Signature of Applicant/Agent: RAADate: SUPPLEMENTAL INFORMATION REQUIRED n> F"ri FncF nNl.v PVApp_2011.doc revised 03116111 i O RECEIVED .r n ianS®lar Canadian Solar's new Quartech modules have significantly raised the standard of module efficiency in the solar industry. They introduced innovative four busbar cell technology, which demonstrates higher power output and higher system reliability. Worldwide, our customers have embraced this next generation of modules for their excellent performance, superior reliability and enhanced value. NEW TECHNOLOGY Reduces cell series resistance Reduces stress between cell interconnectors Improves module conversion efficiency Improves product reliability KEY FEATURES ck frame Juct can be Tided upon request. insurance -backed warranty 25 years non -cancelable, immediate warranty insurance linear power output warranty 10 1 product warranty on materials =; years ; and workmanship Higher energy yield MANAGEMENT SYSTEM CERTIFICATES Outstanding performance at low irradiance ISO 9001:2008 / Quality management system Maximum energy yield at low NOCT ISO/TS 16949:2009 /The automotive industry quality management system Improved energy production through ISO 14001:2004/ Standards for environmental management system reduced cell series resistance OHSAS 18001:2007 / International standards for occupational health & safety Increased system reliability PRODUCT CERTIFICATES Long-term system reliability with IP67 IEC 61215/IEC 61730: VDE/MCS/CE /JET/SII/CECAU/INMETRO/CQC junction box UL 1703 /IEC 61215 performance: CEC listed (US) / FSEC (US Florida) Enhanced system reliability in extreme UL 1703: CSA / IEC 61701 ED2: VDE / IEC 62716: VDE / IEC 60068-2-68: SGS temperature environment with special PV CYCLE (EU) / UNI 9177 Reaction to Fire: Class 1 cell level stress release technology Extra value to customers Positive power tolerance up to 5 W Stronger 40 mm robust frame to hold snow load up to 5400 Pa and wind load up to 2400 Pa Anti -glare project evaluation Salt mist, ammonia and blowing sand resistance apply to seaside, farm and desert environments x i D E OBWt; PV CYCL e )E +� J -- CANADIAN SOLAR INC. is committed to providing high quality solar products, solar system solutions and services to customers around the world. As a leading manufacturer of solar modules and PV project developerwith about 10 GW of premium quality modules deployed around the world since 2001, Canadian Solar Inc. (NAS— DAQ: CSIQ) is one of the most bankable solar companies worldwide. CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario N1 K 1 E6, Canada, www.canadiansolar.com, support@canadiansolar.com MODULE / ENGINEERING DRAWING (mm) Rear View Frame Cross Section A -A 35 11 Mounting Hole F R 0,__ ELECTRICAL DATA / STC* Electrical Data CS6P 260P 265P Nominal Max. Power (Pmax) 260 W 265 W _ Opt. Operating Voltage (Vmp) Opt. Operating Current (Imp) 30A V 30.6 V 8.56 A_ 8.66 A �37.7 Open Circuit Voltage (Voc) — 37.5 V V____ Short Circuit Current (Isc) Module Efficiency_! __ _ 9.12 A 9.23 A 16.16% 16.47% _ Operating Temperature_ -40°C — +85°C Max. System Voltage 1000 V (IEC) or 1000 V (UQ Module Fire Performance TYPE 1 (UL 1703) or CLASS C (IEC61730) Max. Series Fuse Rating 15 A — Application Classification __ Power Tolerance Class A _ 0 — + 5 W * Under Standard Test Conditions (STC) of irradiance of 1000 W/m2, spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA / NOCT* Electrical Data CS6P _ 260P 265_P_ _ Nominal Max. Power (Pmax) 189 W _ 192 W _ Opt. Operating Voltage (Vmp) 27.7 V 27.9 V Opt. Operating Current (Imp) 6.80 V 6.88 A Open Circuit Voltage (Voc) 34.5 V 34.7 V _ Short Circuit Current (Isc) 7.39 A 7.48 A * Under Nominal Operating Cell Temperature (NOCT), irradiance of 800 W/m2, spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. PERFORMANCE AT LOW IRRADIANCE Industry leading performance at low irradiation, average +96.5% relative efficiency from an irradiance of 1000 W/m2 to 200 W/m2 (AM 1.5, 25°C). The specification and key features described in this datasheet may deviate slightly and are not guaranteed. Due to on -going innovation, research and product enhancement, Canadian Solar Inc. reserves the right to make any adjustment to the information described herein at any time without notice. Please always obtain the most recent version of the datasheet which shall be duly incorporated into the binding contract made by the parties governing all transactions related to the purchase and sale of the products described herein. Caution: For professional use only. The installation and handling of PV modules requires professional skills and should only be performed by qualified professionals. Please read the safety and installation instructions before using the modules. CS6P-260P / I-V CURVES A 10 9 a 7 6 5 4 3 2 6 4 3 2 1 V 0 5 10 15 20 25 30 35 40 A 5 10 15 20 25 30 35 40 IM 1000 W/m' S°c ❑ Ci 300 W/m' 25°C Ci 600 W/m' 45°C ❑ Efl 400 W/m' 65°C ❑ MODULE / MECHANICAL DATA specification Data Cell Type ______Poly -crystalline, 6 inch Cell Arrangement, 60 (6x10) Dimensions 1638x982x40 mm (64.5 x38,7x1.57 in) _ Weight-- 18 kg (39_7 Ibs) T Front Cover 3.2 mm tempered glass _ Frame Anodized aluminium alloy_____ -Material J-Box IP67, 3 diodes Cable 4 mm2 (IEC) or 4 mm2 & 12AWG 1000 V (UL), 1000 mm (39.4 in) (650 mm (25.6 in) is optional) Connectors Friends PV2a (IEC), Friends PV2b (IEC / UQ Standard 26 pieces, 515 kg (1135.4 Ibs) Packaging (quantity & w_eight per [let) Module Pieces per Container 728 pieces (40' HQ) TEMPERATURE CHARACTERISTICS Specification Data T_emperature_Coe_fficient (Pmax) `=0.41%/ °C _ Temperature Coefficient (Voc)_ _ -0.31 % / °C Temperature Coefficient (Isc) _ 0.053%/ °C Nominal Operating -Cell Temperature_ 45±21 PARTNER SECTION Scan this QR-code to discover solar M. projects built with this module ;1. CANADIAN SOLAR INC. August 2015. All rights reserved, PV Module Product Datasheet V5.3EN C. . C$A ' Group Certificate of Compliance Certificate: Proj ect: 2284121 70048197 Issued to: Canadian Solar Inc 545 Speedvale Ave West Guelph, Ontario NIK IE6 CANADA Attention: dean -Nicolas Jaubert Faster Contract: 249143 Date Issued: 2015-10-05 The products listed below are eligible to bear the CSA Marls shown with adjacent indicators 'C' and 'US'for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. CP ® Issued by: A 4''lv (A rL4) C US N"e4,v Anh (Andy) Nguyen PRODUCTS CLASS - C531110 - POWER SUPPLIES -Photovoltaic Modules and Panels CLASS - C531190 - POWER SUPPLIES -Photovoltaic Modules and Panels - Certified to US Standards Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type 1 module fire performance, Model Series CS6X-XXXP, CS6X-XXXPX, where'XXX' is the power output from 250 W to 330 W with the following electrical ratings typical at 305 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 44.8 V Short Circuit Current (Isc): 8.97 A Operating Voltage (Vpmax): 36.3 V Current at Operating Voltage (Ipmax): 8.41 A Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type 1 module fire performance, Model Series CS6X-XXXM, where'XXX' is the power output from 260 W to 350 W with the following electrical ratings typical at 350 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 46.6 V Short Circuit Current (Isc): 9.67 A Operating Voltage (Vpmax): 38.3 V Current at Operating Voltage (Ipmax): 9.14 A `&WIM n SSA Croup Certif Cate: 2284121 Project: 70048197 Master Contract: 249143 Date Issued: 2015-10-05 Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type 1 module fire performance, Model Series CS6P-XXXP, CS6P-XXXP-S, CS6P-XXXPX where'XXX' is the power output from 200 W to 275 W with the following electrical ratings typical at 260 W for CS6P-XXXP/ CS6P-XXXP-S, and CS6P-XXXPX series respectively @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 37.5 V Short Circuit Current (Isc): 9.12 A Operating Voltage (Vpmax): 30.4 V Current at Operating Voltage (Ipmax): 8.56 A Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type 1 module fire performance, Model Series CS6P-XXXM and CS6P-XXXMX where'XXX' is the power output from 200 W to 290 W with the following electrical ratings typical at 290 W for CS6P-XXXM and CS6P-XXXMX series respectively @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 38.7 V Short Circuit Current (Isc): 9.59 A Operating Voltage (Vpmax): 31.9 V Current at Operating Voltage (Ipmax): 9.09 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS5A-XXXM, , where 'XXX' is the power output from 170 W to 210 W with the following electrical ratings typical at 210 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 45.6 V Short Circuit Current (Isc): 5.90 A Operating Voltage (Vpmax): 38.1 V Current at Operating Voltage (Ipmax): 5.51 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6A-XXXP, where 'XXX' is the power output from 160 W to 210 W with the following electrical ratings typical at 210 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 30.0 V Short Circuit Current (Isc): 9.19 A Operating Voltage (Vpmax): 24.4 V Current at Operating Voltage (Ipmax): 8.63 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6F-XXXM, where'XXX' is the power output from 30W to 40W with the following electrical ratings typical at 40W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.8 V Short Circuit Current (Isc): 2.28 A Operating Voltage (Vpmax): 18.6 V Current at Operating Voltage (Ipmax): 2.15 A .......... I. Certificate: 2284121 Project: 70048197 Master Contract: 249143 Date Issued: 2015-10-05 Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6F-XXXP, where'XXX' is the power output from 30W to 40W with the following electrical ratings typical at 40W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.6 V Short Circuit Current (Isc): 2.32 A Operating Voltage (Vpmax): 18.4 V Current at Operating Voltage (Ipmax): 2.17 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6H-XXXM, where 'XXX' is the power output from 20W to 26W with the following electrical ratings typical at 26W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.7 V Short Circuit Current (Ise): 1.5 A Operating Voltage (Vpmax): 18.4 V Current at Operating Voltage (Ipmax): 1.41 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6H-XXXP, where 'XXX' is the power output from 20 W to 26 W with the following electrical ratings typical at 26 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.5 V Short Circuit Current (Ise): 1.52 A Operating Voltage (Vpmax): 18.2 V Current at Operating Voltage (Ipmax): 1.43A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6E-XXXM, where'XXX' is the power output from 45 W to 60 W with the following electrical ratings typical at 60 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.8 V Short Circuit Current (Ise): 3.42 A Operating Voltage (Vpmax): 18.6 V Current at Operating Voltage (Ipmax): 3.23 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6E-XXXP, where 'XXX' is the power output from 45 W to 60 W with the following electrical ratings typical at 60 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.6 V Short Circuit Current (Ise): 3.47 A Operating Voltage (Vpmax): 18.4 V Current at Operating Voltage (Ipmax): 3.26 A CSA Group Certificate: 2284121 Project: 70048197 Master Contract: 249143 Date Issued: 2015-10-05 Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6D-XXXM, where'XXX' is the power output from 60 W to 75 W with the following electrical ratings typical at 75 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.5 V Short Circuit Current (Ise): 4.37 A Operating Voltage (Vpmax): 18.3 V Current at Operating Voltage (Ipmax): 4.11 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6D-XXXP, where'XXX' is the power output from 60 W to 75 W with the following electrical ratings typical at 75 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.3 V Short Circuit Current (Ise): 4.43 A Operating Voltage (Vpmax): 18.1 V Current at Operating Voltage (Ipmax): 4.15 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6C-XXXM, where 'XXX' is the power output from 120 W to 175 W with the following electrical ratings typical at 145 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.4 V Short Circuit Current (Ise): 8.52 A Operating Voltage (Vpmax): 18.1 V Current at Operating Voltage (Ipmax): 8.01 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6C-XXXP, where'XXX' is the power output from 120 W to 165 W with the following electrical ratings typical at 150 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.3 V Short Circuit Current (Ise): 8.87 A Operating Voltage (Vpmax): 18.1 V Current at Operating Voltage (Ipmax): 8.30 A Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type 1 module fire performance, Model Series CS6K-XXXP, where'XXX' is the power output from 220 W to 275 W with the following electrical ratings typical at 275 W for CS6K-XXXP series @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 38.0 V Short Circuit Current (Ise): 9.45 A Operating Voltage (Vpmax): 31.0 V Current at Operating Voltage (Ipmax): 8.88 A .P CSA F" ,r Group Certificate: 2284121 Project: 70048197 Master Contract: 249143 Date Issued: 2015-10-05 Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6A-XXXM, where'XXX' is the power output from 160 W to 230 W with the following electrical ratings typical at 205 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 30.6 V Short Circuit Current (Ise): 9.31 A Operating Voltage (Vpmax): 24.8 V Current at Operating Voltage (Ipmax): 8.87 A Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type 1 module fire performance, Model Series CS6K-XXXM, where 'XXX' is the power output from 240 W to 290 W with the following electrical ratings typical at 290 W for CS6K-XXXM series @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 38.7 V Short Circuit Current (Ise): 9.59 A Operating Voltage (Vpmax): 31.9 V Current at Operating Voltage (Ipmax): 9.09 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6P-XXXP-SD, and CS6K-XXXP-SD where'XXX' is the power output from 240 W to 275 W with the following electrical ratings typical at 250 W @ Standard Test Condition (STC): Output Voltage Range (Vout): 5 — 60 V Maximum Output Current (Imax): 15 A Photovoltaic Modules with maximum system voltage of 600V or 1000 V do and Type 1 module fire performance, Model Series CS6P-XXXP-TD, where 'XXX' is the power output from 240 W to 275 W with the following electrical ratings typical at 250 W @ Standard Test Condition (STC): Output Voltage Range (Vout): 16 — 32 V (Voc*) Maximum Output Current (Imax): 9.5 A *For modules with Smart Curve function the Voc is adjustable and is programmed only at the factory based on the PV module voltage. Notes: Rated electrical characteristics are within +/-10% of measured values at Standard Test Conditions of 100 mW/cm2 irradiance, AM 1.5 spectrum, and cell temperature of 25°C. APPLICABLE REQUIREMENTS ULC/ORD- C1703-01 - Flat -Plate Photovoltaic Modules and Panels UL 1703-3`d Edition - Flat -Plate Photovoltaic Modules and Panels Supplement to Certificate of Compliance Certificate: 2284121 (249143) Project 70048197 Master Contract: 249143 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Product Cerfi eatiou History Date Description 2015-10-05 Update Report 2284121 for 1. Seven new cell technologies 2. Two new J-box tested with 13 different combinations of backsheets and adhesive 3. New J- box and frame adhesive 4. New clamping method for ZEP frame 5. Mounting on NexTracker 6.Removal of obsolete models and materials 7. Update F1 frame for NexTracker and ATI trackers 8. Update HF10 test results for Boviet Solar factory 70043990 2015-09-10 Provide Report Update to add BF test results 70031273 2015-05-01 Update test report no. 2284121 for 1. Alternate EVA -' Changshu Tegu New Material Technology Co. Ltd.', types 72014" and 72053", 0.45-0.5 mm nominal thickness, two sheets provided (T2014 type above cell strings - superstrate side - and T2053 type below - substrate side) 2. Alternate Substrate - (Suzhou) Sunwatt Co., Ltd.', white type "KFB-30" overall thickness, 0.290 mm nominal. 3. Alternate Substrate -'Crown Adbanced Material Co., Ltd.', white type "BE-D2", overall thickness, 0.390 mm nominal 4. Add new Model Series CS6P-XXXP-TD , 240 W to 275 W range, with Tigo DC optimizer 5. Alternate Jbox -'Changshu Friends Connector Technology Co., Ltd', junction box type CF1108-03g, rated 600 V dc, 11A 6. Alternate Jbox - 'Changshu Friends Connector Technology Co., Ltd', junction box type CF1108-03g b, rated 1000 V dc, 1 IA 7. Alternate Jbox - #Tigo energy Inc.#, junction box type MMJ-ES50, with Smart Curve function, rated 1000 dc, 9.5A 8. Alternative Cables: For use with MMJ-ES50 junction boxes only, on CS6P-P-TD, NRTL approved type PV wire No. 12 AWG, rated 600 V minimum. Outer diameter 6.7±0.20 mm, 90°C minimum, marked sunlight resistant 9. Add new bypass diode 30CTQ100S (For use with MMJ-ES50 junction boxes only), rated 100v, 30A 10. Alternate mounting system - CS6X-xxxPX with ZS Peak mounting system 11. Alternate mounting system - CS6X-xxxP with Array Technology Inc, DuraTrack# HZ Solar Tracker V3 clamps and torque tube 12. Alternate grounding method - for Brilliant Rack Ground Mount System. 13. 70016938 2015-01-09 Update Report 2284121 to Include Vietnam Factory "Viva Solar Technology" 70015998 2014-12-24 Update Report 2284121 to add model CS6P-P-SD (w/Solaredge Optimizer), CS6P-P-TD(w/Tigo optimizer), four alternative cells and alternative grounding method. CSA Group Certificate. 2284121 Project: 70048197 piaster Contract: 249143 Bate Issued: 2015-10-05 70013912 2014-10-30 Update Report 2284121 to include two alternative cells and alternative grounding methods. 2761996 2014-09-24 Update Report 2284121 to add Celestica, ON as a Factory; IFE Not Required 2749251 2014-07-25 Update to include alternative cells, EVA, backsheet, potting compound and grounding methods. 2725910 2014-05-15 Update Report 2284121 to include the addition of series -M and -MM and alternative construction. 2679144 2014-01-31 Add Factory "Canadian Solar Solutions Inc, London, ON". 2676999 2013-11-13 Update to include an alternative EVA, backsheet, junction box and cells. 2633572 2013-07-08 Update to include two alternative backsheets and two cells. 2618121 2013-04-19 Update to include an alternative EVA, backsheet, junction box, junction box adhesive and cells. 2604442 2013-02-26 Update to include changes to cells, alternative EVA and addition of series CS6K. 2600055 2013-02-06 Update to include an alternative mounting system. 2594501 2013-01-17 Update to inlcude alternative junction box and a number of poly and mono cells. 2584786 2013-01-03 Update to add factory "CSI Central Power". 2587786 2012-12-19 Update to include changes to cells, alternative j-box and back sheets BEC- 301 by Hangzhou First and VTPEIRW by Taiflex. 2559421 2012-09-26 Update to include the addition of Flexcon KPE backsheet. 2542034 2012-07-06 Update to include new half cell modules series PT, addition of 1000 V rating, alternative j-boxes and adhesive. 2496460 2012-06-15 Evaluation to add backsheet from COVEME for all the module series (with F806 EVA, CM0804 junction box and Tonsan 1527 adhesive). 2515777 2012-06-12 Update to include the evaluation of factory location in South Korea (includes HF10 test sequence). 2532459 2012-06-05 Update to include new models (smaller modules), alternative cells and backsheets. 2512339 2012-03-28 Update to include alternative cells. 2508436 2012-03-21 Update to include three alternative cells and an alternative Toyo back sheet. 2490216 2012-01-13 Update to add CSSP-xxxP and CSSA-XXXP Series. 2458713 2011-12-19 Evaluation for an alternative (Shunfeng) cell and j-box with Isovolta AAA backsheet with PV744 adhesive. 2480024 2011-12-01 Evaluation for alternative JA Solar cells and to add new series. Certificate: 2284121 Project: 70048197 2470474 2011-10-28 2455625 2011-09-02 2441645 2011-07-26 2431019 2011-06-03 2404638 2011-04-18 2390337 2011-02-08 2380821 2010-12-17 2284122 2010-10-14 2284121 2010-06-30 CSA S A Group Master Contract: 249143 Date Xssued: 2015-10-05 Update to add the laminates (without frame). Update to add smaller modules with cut cells. Update to include change in glass dimensions, black backsheet, new frame and new j-box and edgeseal adhesive. Update to include the addition of model series CS6A and use of alternative mateirals and components. Update to include an alternate lamination line, includes HF10 test sequence. Addition of factory location in Ontario. Update to include Model Series CS5A-XXXM and CS5T-XXXM. Addition of 72 cell series CS6X-XXXP and CS6X-XXXM. Evaluation of PV Panel Series for C/CSA/US Mark. For North America - Integrated arc fault protection for NEC 201l69O,l1compliance - Rapid shutdown for NEC 2014S90.lZ ~ Superior efficiency (9O>6) ~ Small, lightweight and easy toinstall onprovided bracket ~ Built-in module -level monitoring - Internet connection through Ethernet o/Wireless ~ Outdoor and indoor installation ~ Fixed voltage inverter, DC/AC conversion only ~ Pre -assembled Safety Switch for faster installation ~ Optional — revenue grade data, ANSI [12l Sin& PhaS@ d�� rtgrS for North America Sa rZe ® SE300OA-US J SE380OA-US / SE5000A-US / SE600OA-US / SE760OA-US / SE10000A-US / SE1140OA-US �SE3000A-US SE38QQA US SE5000A-US I SE600CA US ISE7600A US j SEIQQOOA- US SE114QOA US OUTPUT --�--� -Nominal i 9980 @ 203V AC Power Output ; 3000 f 3800 I 5000 6000 7600 10000 @240V 11400 VA Max. AC Power Output $ 3300 4150 5400 @ 208V 5450 @240V ( 6000 la 8350 10800 @ 208V 10950 @240V 12000 VA AC Output Voltage Min: Nom: tVlax.t'I I j f I 183 - 208 - 229 Vac if AC Output Voltage Min: Nom: Max.)t) ✓ d ✓ 211- 240 - 264 Vac I I I AC Frequency Min: Nom: Max.lal 59.3 - 60 - 60.5 Hz Max. Continuous Output Current 12.5 16 24 @ 208V 25 32 21 @ 240V j 48 @ 208V 42 @ 240V 47.5 A GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable ThresholdsYes Yes INPUT Maximum DC Power(STC) f 4050 5100 T 6750 8100 10250 13500 15350 1-W Transformer -less, Ungrounded S Yes Max. Input Voltage i 500 Vdc Nom. DC Input Voltage 325 @ 208V / 350 @ 240V Vdc III 16.5 @ 208V 33 @ 208V Max. Input Current(') 9.5 13 18 23 15.5 @ 240V j j 30.5 @ 240V t 34.5 Adc Max, Input Short Circuit Current 45 I Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600ka Sensitivity Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 98 CEC Weighted Efficiency i ! 97.5 i 98 97 @ 208V ( 97.5 97.5 97 @ 208V 97.5 30 98 @ 240V 97.5 @ 240V Nighttime Power Consumption < 2.5 < 4 1W ADDITIONAL FEATURES Supported Communication interfaces RS485, RS232, Ethernet, ZigBee (optional) Revenue Grade Data, ANSI C12.1 Optionallal Rapid Shutdown -NEC 2014 690.12��^ - Yes STANDARD COMPLIANCE Safety _ UL1741, UL1699B, UL1998 , CSA 22.2 Grid Connection Standards IEEE1547 Emissions FCC part15 class B I INSTALLATIONSPECIFICATIONS AC output conduit size / AWG range 3/4" minimum / 16-6 AWG 3/4" minimum / 8-3 AWG DC input conduit size / # of strings / 3/4" minimum / 1-2 strings / 16-6 AWG 3/4" minimum / 1-3 strings / AWG range 14-6 AWG Dimensions with Safety Switch 30.5 x 12.5 x 7.2 / 775 x 315 x 184 30.5 x 12.5 x 10.5 / in / (HxWXD) 775 x 315 x 260 mm Weight with Safety Switch 51.2 / 23.2 54.7 / 24.7 88 .4 / 40.1 lb / kg Cooling Natural convection Natural Convection and internal ( Fans (user replaceable) fan (user {!i replaceable) Noise < 25 < 50 Min. -Max. Operating Temperature i -13 to +140 / -25 to +60 (-40 to +60 version available")) Range Protection Rating NEMA 311 For other regional settings please contact SolarEdge support. A higher current source maybe used; the inverter will limit its input current to the values stated. 13j Revenue grade inverter P/N: SExxxxA-US000NNR2(for 760OW inverter.SE760OA-US002NNR2). -40 version P/N: SExxxxA-USOOONNU4 (for 760OW mverter:5E7600A-US002NNU4). dBA F/"C sola SolarEdge Power Optimizer Module Add -On For North America WI I WNFAMNIII I 2 I, PV power optimization at the module -level — Up to 25% more energy Superior efficiency (99.5%) — Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module -level monitoring Module -level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us Solar =@ Module Add -On for Forth America P300 / P320 / P400 / P405 P300 I P320 I P400 P405 ( (for high -power (for 72 & 96-cell (for thin film (for 60-cell modules) - tin it mnrhdac) modules? I modules) INPUT Rated Input DC Powerl'l 300......................320...........,........,..400......................405................ W .,... Absolute Maximum Input Voltage ! 48 80 125 Vdc (Voc at lowest temperature} ............................,..................., ........................... ........... ...... ....i MPPT Operating Range 18 - 48 I 8 ; 80 „ I 12,5 -105 1 .............,......,...... Vdc Maximum Short Circuit Current Isc} .............. ii 10 I.. 11....................................a_,,,_,,,,,,•_. ..........,....,..... ,,,Adc.._. .......................................i....,,.................,.... Maximum DC Input Current 12.5 1..........13 75 125........................! Adc ..... Maximum Efficiency Maximum �................................... 99 5 e 1............. a ........................ Weighted Efficiency........,.,, 98.8 Overvoltage Category I II I OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc ......................................60....................................... ............,............. ...... ....... ...... Maximum Output Voltage 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE4NVERT,ER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power I 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000 ,6.2: IEC61000 6-3 ........................_............................................. S* *.. IEC62109-1(class 11 safety): UL1741 i ....X..........I..................... �.... ........ RoHS I _ Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage ...................... 1000 ...........,........................................................................ Vdc ........... Compatible inverters { All SolarEdge•Single Phase and Three Phase inverters ................... I 128x152x27.5/ 128x152x35/ 128x152x48/ mm/In Dimensions(WxLxH) 5x5.97x1.08 5x597x137 5x597x189 ......... Weight (inciudin cables l 1.7 ....... 930 / 2.05 ........ ................. i 930 2 :05 In ut Connector MC4 Compatible ......... ,,.,,, Output Wire Type /Connector I Double insulated; MC4 Compatible ................. .. ....... Out ut Wlre Len th p..............g I D.95 3.0 (..,., 1.2 / 3.9 I m / ft ......................I.........._...........,....�....... OperafinBTemperatureRanBe I ............................... .-40-t85/ 40-+185 .................... .................... ! `C/,F Protection Ratln I ........ IP_....68 / ..NEMA6P .... ............. .... Relative Humidity ................ 0-100 ............. In Rated STC power of the module. Module of up to +5% power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTERI2). Minimum String Length^--- 8 10 18 Power Optimizers...............I..............................._.-.. .. . . . .... . .. Maximum String Length 25 25 50 (Power Optimizers?.. ....� ................. �. Maximum Power per String j ._...5250 I.,... 6000..............1_ ....... 12.... i W ........ ... Parallel Strings of Different Lengths .. Orientations ...1................ .rOri. t t........................... e5................................................................. R1 It is not allowed to mix P405 with P300/P400/P600/P700 in one string. THE SNAPNRACK S TILE ROOF HOOK OFFERS A QUICK, COST EFFECTIVE SOLUTION FOR MOUNTING ON S-TILE ROOFTOPS. THE SIMPLE DESIGN HAS BEEN OPTIMIZED FOR SNAPNRACK AND THE HOOKS ARE BUILT INTO OUR SYSTEM ENGINEERING AND UL LISTING, ONCE A TILE HAS BEEN REMOVED, THE BASE PIECE IS BOLTED DOWN TO A RAFTER. ONCE THE BASE IS IN PLACE, THE TILE HOOK ARM IS INSERTED INTO THE HOOK FEATURE IN THE BASE AND ROTATED DOWN TOWARDS THE TRACK SO THAT THE BONDING CHANNEL NUT SNAPS INTO THE CHANNEL. ONCE THE ARM IS ATTACHED TO THE BASE, SLIDE IT ON THE BASE SO THAT IT ALIGNS WITH A LOW POINT IN THE S-TILES, SIMPLY TIGHTEN IT IN PLACE AND REPLACE THE TILE THAT WAS REMOVED. WITH SOME TYPES OF TILE YOU MAY WANT TO DO A LITTLE GRINDING TO HELP EVERYTHING FIT BACK TOGETHER SMOOTHLY, BUT IN MANY CASES NO GRINDING IS REQUIRED. INSTALLATIONS OF SNAPNRACK S TILE ROOF MOORS .492E LlMnTED TO A MA)LIMUM WIND SPEED OF 12OMPH (IBC 2012) ARID A MA)aMUM A' 7ACIHMENT SPAN OF 6FTo SNAPNRACK STANDARD RAIL SNAPNRACK BONDING CHANNEL NUT t" - 18 X 1.25" STAINLESS STEEL FLANGE BOLT SNAPNRACK BONDING CHANNEL NUT 0 SNAPNRACK STANDARD RAIL S-TILE, TYP SNAPNRACK S-TILE HOOK ARM TILE BATTEN, TYP.- ROOF DECKING, TYP. A" LAG BOLTS WITH FLAT STEP 1: REMOVE TILES TO EXPOSE ROOF DECKING. SNAPNRACK S-TILE HOOK ARM fl� REVISION: SNAPNRACK S-TILE HOOK BASE f ENSURE 2.5" MINIMUM EMBEDMENT INTO RAFTER, TYP. RAFTER OR OTHER STRUCTURAL ROOF MEMBER, TYP. SNAPNRACK STANDARD RAIL SNAPNRACK S-TILE HOOK BASE STEP 3: -I SLIDE THE S-TILE HOOK ARM m' LAG BOLTS WITH INTO THE HOOK ON THE BASE AND ROTATE THE ARM TOWARDS THE BASE TO SNAP THE CHANNEL NUT INTO THE CAHNNEL. TIGHTEN FLANGE BOLT HAND TIGHT. ALIGN THE ARM WITH THE NEAREST VALLEY IN THE TILES AND TIGHTEN BOLT TO 10-16 FT-LBS FLAT WASHERS s )) STEP 2: ROOF DECKING, TYP. LAG BOLTS WITH FLAT WASHERS DRILL TWO is" PILOT HOLES INTO HOOK CAN BE OFFSET FROM RAFTER. SEAL ROOF PENETRATIONS RAFTER UP TO 5" IN EITHER WITH APPROPRIATE SELANT. RAFTER OR OTHER STRUCTURAL --'DIRECTION TO LINE UP WITH FASTEN BASE TO ROOF WITH QTY. (2) ROOF MEMBER, TYP. LOW POINT IN S-TILES. 51. 36 LAG BOLTS WITH FLAT WASHERS. n(�� S ap V �ack pM moufflo g ftaftum MAINSTREAM ENERGY CORP. )BW�R6RSAN F"Y �0-0.B ""�R P �°"��°'s "`°"°�gP°'� °' "s" _ DESIGNER: G McPheeters D Ryan DRAFTER: Y APPROVED BY: SCALE: DNS PART NUMBER: S100 PEN D14 DESCRIPTION: SERIES 100 PEN DETAIL 14, S-TILE HOOK REV F DATE: 031613 SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS LE of CONTENTS [PA7GE# DESCRIPTION • SYSTEM SIZE: 6625W DC, 6000W AC ALL WORK SHALL COMPLY WITH CRC 2013,2013 CEC, 2013 CBC, MUNICIPAL SE SERVICE ENTRANCESOLAR MODULES COVER SHEET • MODULES: (25) CANADIAN SOLAR: CS6P-265P CODE, AND ALL MANUFACTURERS'LISTINGS AND INSTALLATIONRAIL V-2.0 SITE PLAN • INVERTER(S) INSTRUCTIONS. (1) SOLAREDGE TECHNOLOGIES: SE6000 (240V) W/-ER-US • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2013 CEC. MP MAIN PANEL PV-3.0 LAYOUT OR A -US • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2O13 CEC.. PV-3.1 LAYOUT • RACKING: SNAPNRACK SERIES 100 UL; UNIVERSAL TILE • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY - PV-4.0 ELECTRICAL HOOK. SEE PEN D14 GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. SP SUB -PANEL STANDOFFS & • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. FOOTINGS PV-5.0 SIGNAGE • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. LC PV LOAD CENTER CHIMNEY -_ • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(E) AND 2012 = IFC 605.11:2. Q = • ARRAY -DC CONDUCTORS ARE SIZED FOR DERATED CURRENT: SUNRUN METER - ATTIC VENT • 9.23 -_AMPS MODULE SHORT CIRCUIT CURRENT. SM • 14.42 AMPS DERATED SHORT CIRCUIT CURRENT (690.8 (a) & 690.8 (b)). FLUSH ATTIC VENT ---- - PM DEDICATED PV METER77 -- o? PVC PIPE VENT C 17 _- N_ INVERTER(S) WITH ® = METAL PIPE VENT IN INTEGRATED DC r!Ay 1 � Luigi - DISCONNECT AND AFCI ® T-VENT - _ - AC DISCONNECT(S) ACC SATELLITE DISH DC DISCONNECT(S) FO FIRE SETBACKS CB COMBINER BOX- HARDSCAPE copy INTERIOR EQUIPMENT — PL- PROPERTY LINE LE a SHOWN AS DASHED SCALE: NTS sunrun A' AMPERE AC ALTERNATING CURRENT - _ -- AFCI ARC FAULT CIRCUIT INTERRUPTER GILBERT GORREIA, c10, cas - AZIM AZIMUTH CA CL #750184 VICINITY -MAP - COMM-ri'!iTY DEv'ELOPMENT DEPARTMENT _ COMP COMPOSITION 2300 ZANKER ROAD, UNIT F, SAN JOSE, CA 95131 PHONE 408.746.3062 _ - BUILDINIG DIVISION - CUPERTINO _ DC DIRECT CURRENT FAx4oa.694.9zsa i -„ t3reenleafDr I - - - (E) EXISTINGnry3, r;D EXT EXTERIOR CUSTOMER RESIDENCE: ANP 69�kvArd {+ht, t of ^ians and specifications MUST be kept at the = _ FIRM FRAMING YOUZHONG LIU Greenl' during construction. It is unlawful io make any INT INTERIOR 20888 FARGO DR, CUPERTINO, fir: c t�; alterations on same, or to deviate LBW LOAD BEARING WALL v31. - : unbar D��,. . . . C 4 i �p f r +".rJ+n, �rithout approval from the Building Official. w MAG MAGNETIC A 9501 ,. p 9 P p ICE PANEL - `otnLiar The r+ ;rn in of this Ian and's ecifications SHALL NOT W SERVICE RO(ao ss t E • ¢ 11 ny_+i to permit or t b an approvel of the violation MSP MA R° pp 6gb jrq N#. NOT TO SCALE U �I� - n �. S8�Lf �NTS 12 any provic. r of, .r i ity Ordinance or State Law. C ON CENTER F. D�" i -z s-, g�. PRE-FAB PRE -FABRICATED ;r e��F�` `DESIGNER: — .— _ {{I` DATE ��( q'`ZGI PSF POUNDS PER SQUARE FOOT _ r� r+ TYLER KINCA�I�D. '�� ktti ertandChlltl - + ia, . ° - RE d . D FOR CO - CE PV PHOTOVOLTAIC +-�(I Ef htC. 949.705.3959 __Jiazelbrools:o,I-ar, • o iet9Pn�nrce��r: ,r . PERMIT NO. 1' %(il�p -' 2 TL TRANSFORMERLESS V3C U Dp . I TYP TYPICAL -Vic)We d By: BIEL�j V VOLTS { `' �► KE® BY W WATTS SHEET *6;REV NAME, DATE COMMENTS COVER SHEET i+ Garden Gate Qr`,Garclen.Gat`eUt� - ATE A E Garden Gate Qf REV: A.4 5/12/2016 �{ !� i�Dt .., PLANNIN DEPT ° � qr I CUPERTINO PAGE PV_ 1 0 SITE PLAN - SCALE = 3/64" = 1'0" T AZIM M ZIM PV AREA Q AR-01 18° 90° 76° 69.3 ® AR-02 180 180° 166° 34.7 AR-03 180 2700 2560 69.3 AR-04 18° 180° 166° 69.3 AR-05 18° 270° 2560 190.7 (N) A (N)� FIRE (N) (E (E) FENCE (N) ARRAY AR-01 sunrun GILBERT CORREIA, C10, C46 (E) FENCE CA CL #750184 2300 ZANKER ROAD, UNIT F, SAN JOSE, CA 95131 (N) ARRAY AR-02 PHONE 408.746.3062 FAX 408.894.9294 CUSTOMER RESIDENCE: YOUZHONG LIU 20888 FARGO DR, CUPERTINO, CA, 9501�4rz R-f,I NOci TEL)) CT NUMBER: 88p8WU REVI�l�,`=�+ F ftVClE �KrWCA�ID�I�'�1�� ! ��wViOvue f / ,7 949.705.31 . t�f� FRAFTER. RBIEL2 SHEET SITE PLAN REV: A.4 5/12/2016 PAGE PV-2.0 ROOF FRAME FRAME TYPE FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA ROOF TYPE ATTACHMENT ROOF HEIGHT EXPOSURE MATERIAL SIZE SPAN SPACING ZONE SPAN OVERHANG MODULES: AR-01 CONCRETE TILE [CURVED] UNIVERSAL TILE HOOK. SEE PEN D14 TWO STORY ATTIC WOOD RAFTER 2 X 8 15' - 0" 16" 3'- 0" 8' - 0" 2' - 8" CANADIAN SOLAR: CS6P-265P AR-02 CONCRETE TILE [CURVED] UNIVERSAL TILE HOOK. SEE PEN D14 TWO STORY ATTIC WOOD RAFTER 2 X 8 15' - 0" 16" 3' - 0" 8' - 0" 2'-8" MODULE DIMS: 64.5" x 38.7" x 1.57" AR-03 CONCRETE TILE [CURVED] UNIVERSAL TILE HOOK. SEE PEN D14 TWO STORY ATTIC WOOD RAFTER 2 X 8 15' - 0" 16" 3'- 0" 8' - 0" 2'- 8" MODULE CLAMPS: Portrait: 13.39" - 16.14" AR-04 CONCRETE TILE [CURVED] UNIVERSAL TILE HOOK. SEE PEN D14 = TWO STORY ATTIC WOOD RAFTER 2 X 8 15' -0 16" 3' - 0" 8' - 0" 2' - 8" Landscape: 7.87" - 9.84" - - MAX DISTRIBUTED LOAD: 3 PSF D1 - AR-01 - SCALE: 1/8" = 1'-0" D2 - AR-02 - SCALE: 1/8" = V-0" SNOW LOAD: 110 PSF PITCH: 180 PITCH: 18' WIND SPEED: AZIM:90° AZIM:180° 0 MPH 3-SEC GUST. LAG SCREWS: 5/16"x3.5": 2.5" MIN EMBEDMENT 5'-6" I - 5'-4" TYP a 10'-101, I I I I I 5' 4 5'-4" TYP 2 X 8 RAFTER 16" OC 1 I 2'-1" 2 X 8 RAFTER 16" OC , sunrun D3 - AR-03 - SCALE: 1/8" = V-0" D4 - AR-04 - SCALE: 1/8" = V-0" � PITCH: 18' PITCH: 18' GILBERT CORREIA, C10, C46 AZIM:2700 AZIM:180' CA CL #750184 ® ® PHONE E 408.7 ROAD, UNIT F, SAN JOSE, CA 98131 PHONE 408.746.3062 FAX 408.894.9294 - CUSTOMER RESIDENCE: YOUZHONG LIU 20888 2 X 8 RAFTER 16" OC CA, 95014GO DR, CUPERTINO, TEL. (408) 462-1188 APN #: --- / 5' 411 TYP 4 6' I6 I iv1 I I I 1 4 5 `t r,. IWAY ! DESIGNER: TYeER KINCAID 949.705.3959 ,, -VIEWED FOR GO bRgPT�ts.lA� lCE - i— i�Pvis--wed H= g� L2,jj ,�/ 3 7" I SHEET 10'-9" 10'-3" 2 X 8 RAFTER 16" OC LAYOUT REV: A.4 5/12/2016 PAGE PV-3.0 ROOF FRAME FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA MODULES: ROOF TYPE ATTACHMENT ROOF HEIGHT EXPOSURE MATERIAL FRAME TYPE SIZE SPAN SPACING ZONE SPAN OVERHANG AR-05 CONCRETE TILE [CURVED] UNIVERSAL TILE HOOK. SEE PEN D14 TWO STORY ATTIC WOOD RAFTER 2 X 8 15' - 0" 16" 3' - 0" 8' - 0" 2' - 8" CANADIAN SOLAR: CS6P-265P MODULE DIMS: 64.5" x 38.7" x 1.57" D5 - AR-06 - SCALE: 3/16" = 1'-0" MODULE_CLAMPS: PITCH:-18° _ _ _ -- ----__—Laridscape 7:87" - 9.84" MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF 27' 2'-5" - - - WIND SPEED: 110 MPH 3-SEC GUST. LAG SCREWS: 5/16"x3.5": 2.5" MIN EMBEDMENT NOTE: I INSTALLERS TO VERIFY RAFTER ®I I I I I I I SIZE, SPACING AND SLOPED I SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE 2 X 8 RAFTER 16" OC i I i i I I PROCEEDING. I -�I--5'-4"ITYP I I I ITH 6'-6" T(( III III III I i TIC I; 32'-5" — sunrun ROOF FRAMING DETAIL - SCALE: NTS GILBERT CORREIA, C10, C46 CA CL #750184 2300 ZANKER ROAD, UNIT F, SAN JOSE, CA 95131 PHONE 408.746.3062 FAX 408.894.9294 RIDGE BOARD CUSTOMER RESIDENCE: YOUZHONG LIU 5/16" X 3.5" LAG SCREW. 20888 FARGO DR, CUPERTINO, 2 BOLTS PER PENETRATION CA, 95014 CONCRETE TILE [CURVED] ROOF TEL. (408) 462-1188 APN #: --- PROJECT NUMBER: SOLAR MODULE y�4�2R$88LIU TOP PLATE C'c SrYGhER: RTYLER AT"2X8 KINCAID 949.705.3959 RAFTERS, 16" O.C. y LOAD BEARING WALL LAYOUT REV: A.4 5/12/2016 PAGE PV=3.1 . 120%240VAC SINGLE PHASE SERVICE -1-009 EXISTING 200A MAIN BREAKER EXISTING MAIN FACILITY PANEL (END -FED) LOADS 35APV -c-L-GROUND BREAKER AT OPPOSITE END ` OFBUSBAR 747 250VMBER SOCKET 125ACONT|NUOUS & 24OVMETER 2O0A.,FORM 28 3 (N)LOCKABLE � BLADE TYPE AC DISCONNECT SQUARED OU322RB 3R.GOA.2P SOLARED8E TECHNOLOG|ES:SE0000 (240V)N0'ER,USOR A,US GO0OWATT INVERTER LOAD RATED DC DISCONNECT &AFC| 2 JUNCTION BOX PVMOOULES (25) MODULES OPTIMIZERS WIRED IN (1) SERIES OF(15) OPTIMIZERS AND (1) SERIES OF (10) Lit! OPTIMIZERS SOLAREDGE POWER OPTIMIZER P30] CONDUIT SC14EDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4) 10 AWG PV WIRE NONE (1) 10 AWG BARE COPPER. 3 3/4" EMT OR EQ UIV. (2) 8 AWG THHNfTHWN-2 (1) 10 AWG THHNfrHWN-27(l) 8 AWG THHN/THWN-2 CANADIAN SOLAR: OPEN CIRCUIT VOLTAGE 37.7 V MAX POWER VOLTAGE 30.6 V SHORT CIRCUIT CURRENT 9.23 A OPTIMIZER CHARACTERISTICS MIN INPUT VOLTAGE 8 VDC MAX INPUT VOLTAGE 48 VDC MAX OUTPUT CURRENT 1 15 ADC SYSTEM CHARACTERISTICS''INVERTER 1 SYSTEM SIZE 6625 W SYSTEM OPEN CIRCUIT VOLTAGE 15 V SYSTEM OPERATING VOLTAGE 350 V MAX ALLOWABLE DC VOLTAGE 500 V SYSTEM OPERATING CURRENT 20.4 A SYSTEM SHORT CIRCUIT CURRENT 1 30 A PER CODE: 690.52 NOTES TO INSTALLER: CIRCUIT STRING VOLTAGE. PHONE 408.746.3062 FAX 408.894.929 6-12 AWG BARE 5116" -18 SS BOLT CUSTOMER RESIDENCE: COPPER WIRE SS SPLIT LOCK WASHER YOUZHONG LIU RROJECT NUMBER: ND tSS BONDING R KJ00AW PINS ew V I;_lV4 949.705.3959 NOTE: ALL HARDWARE IS INCLUDED FROM MANUFACTURER DRAFTER: A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY 'RBIEL2 CONTINUOUS ROW OF MODULES GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL TO RAIL SHEET ELECTRICAL ~OR PERPENDICULAR ENSURE SPLIT LOCK WASHER ISINSTALLED "" TOP ", COPPER WIRE rPAGE .0 LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC 690.35(F)) [To be used when inverter is ungrounded] LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC 690.17(E)) LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: CEC 690.17(E), CB LABEL LOCATION: INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT (PER CODE: CEC690.13.G.3 & CEC 690.13.G.4) INVERTER 1 - - -------------- LABEL LOCATION: _ AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.54) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] LABEL LOCATION: MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUCTION BOXES. (PER CODE: IFC605.11.1.4) 'SOLAR DISCONNECT, LABEL LOCATION: DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.13(B)) LABEL LOCATION: WEATHER RESISTANT MATERIAL, DURABLE ADHESIVE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN %" LETTER HEIGHT ARIAL OR----- SIMILAR FONT NON -BOLD, PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED.ON.-- THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.15, 690.13(B)) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(4)) �21 :10YA4 MIMI I i -M LABEL LOCATION: CONDUIT, COMBINER BOX (PER CODE: CEC690.31(G)(3)(4) & CEC 690.13(G)(4) LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC690.53) ADHESIVE FASTENED SIGNS: • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING]. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.31 PLACARD CREATION REQUIREMENTS: • ALL SIGNAGE SHALL BE RED PLASTIC ENGRAVED WITH 1/2" HIGH WHITE LETTERS. CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN SOLAR PANELS ON ROOF MAIN PANEL SERVICE ENTRANCE AND PV � BREAKER DISCONNECT SUNRUN METER AC DISCONNECT INVERTER LOCATION �z RA �E�,'IEV�IE.0 F 20888 FARGO DR, CUPERTINO, C& 95014 t ievle!wed sunrun GILBERT CORREIA, C10, C46 CA CL #750184 2300 ZANKER ROAD, UNIT F, SAN JOSE, CA 95131 PHONE 408.746.3062 FAX 408.894.9294 CUSTOMER RESIDENCE: YOUZHONG LIU 20888 FARGO DR, CUPERTINO, CA, 95014 8 Lr(488 42-1188 APN #: --- T NUMBER: 88LIU DESIGNER: ,� ETLfRII�AttD 949.705.3959 D -AFTER'7�'I tr RBIEL2 SHEET SIGNAGE REV: A.4 5/12/2016 1 PAGE PV-5.0