Loading...
15080094CITY OF CUPERTINO BUILDING PERMIT WILDING ADDRESS: 10900 N BLANEY AVE DWNEWS NAME: PACIFIC GAS AND ELECTRIC CO OWNER'S PHONE: 9252706171 LICENSED CONTRACTOR'S DECLARATION License Class' Li.. # 3 3 Contractor C DatetC7 2- c I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by ction 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments%`" costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regu�ll 'o up e ino Municipal Code, Section 9.18. SiQnatur i[' Date lO 0 OWNER -BUILDER DECLARATION CONTRACTOR: MIR ELECTRIC P 0 BOX 668 MORGAN HILL, QA 95038 PERMIT NO. 15080094 DATE ISSUED: 10/29/2015 PHONE NO: (408) 846-6300 JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL Q PG&E SERVICE CENTER - INSTALL 4 (N) EV CHARGING STATIONS hereby affirm that I am exempt from the Contractor's License Law for one of he following two reasons: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) ?. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (See.7044, Business & Professions Code). 1 hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this r permit is issued. 3. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. Sq. Ft Floor Area:.. ' Valuation: $50000 AP,N Number: 31603045.00 Occupancy Type: PERMIT; EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DA�S FR LED INSPECTION. RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Sienaurre Date__._________— Signature of Applicant: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will maintain compliance with';the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants asdefined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety; Code, Sections 25505, 25533, and 25534. Date: tJ 2 f,5 CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name: Lender's Address ARCHITECT'S DECLARATION I understand my; plans shall be used as public records. Licensed Professional ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 •building cugerlino.Org_ C<UPF-RT1140 PROJECT ADDRESS 10 l co l3- stave AJ L APN R O (,j�- ( V E-MAIL PON'E OWNERNAME P/_ 1 I -2,90141 ?-1 STREET ADDRESS / foo A I • ®J„� CITY, STATE, ZIP u Y J 1,^ a.pl I FAX CONTACT DAME Cit /tie 1 PHOh j ]^Q -t G� [ 4 -74 E-MAIL MIC a� � mi r elecAh C64 STREET ADDRESS CITY, 'r 75-0 fl F g l _ (o S'�� Hd ra ❑ 00.R4ER ❑ OWNER -BUILDER ❑ OWN'ERAGENT 4'CONTi2ACTOR ❑ CONfRACTORAGENTI I] ARC=1CT ®ENGn'TER ❑ DJ EVE ❑ TENANT LICENSE NUMBER p !� LICENSE TYPE rt ► 1 C(BUS. LIC n CONTRACTORNAME I _ c 4' 4� r l� o -t t 39 C tv COT:PANYNAD4E 1770 £-MAIL 1`°l� Gi1 If�t LtnC. fK +o 8 (. ^CiS{}6 � STREET ADDRESS Q �QX P g CITY, STATE, ZIP J (/ C J} 62p PHONE 4 08-q 65- 9 ARCMTECTIENGINEER NAME j �j LICEASE NUMBER ( [ L I �U � BUS. LIC R COMPAIN'Y NAME E-MAIL FAX CITY, STATE, ZIP PHONE STREET ADDRESS USE OF EDSFD or Duplex [I 1�4ulti-Family PROJECT IN WILDLAND PROJECT IN INTERFACE AREA E!YeS P-"" FLOOD ZONE. ❑ Yes O STRUCTURE: ❑ Commercial i / 13 SOLAR WATER HEATING El OTHER: SOLAR PANELS &,ELECTRIC VEHICLE CHARGING STATION KILOWATTS (COMMERCIAL TOTAL VALUATION:b 000 FOR SOLAR PANELS: NUMBER OF PANELSlU,1ITS: DESCRIPTION OF WORK �j�� � attCkbCZ ® kAl l I fig _tel. .. erty 1 read this Eordinances below, I certify to each of the followiI have read the DescriptionOwner or authorized agent to act on the ofof Work and venfj+ rt is accurae.pI eiune eha�f rth all applicable local applicationthe information I have provided is correct. tate laws relating to b ']din cti n. I rize re esentatives of Cupertino toenter the aboident dpr ty for inspection purposes. plicant/Ag _ Dater SUPPLEMENTALTI\IFO A4�.TIONREQUIRED gzkTc�v�Eo.LY - � r , PY.4pp 2011.doc revised 03116111 '�7 CITY OF CUPERTINO TlT.1T Trinrlwmx A T/l77 D7T7TTTN!`_. TiTVTCT(1N I A:IL 1J1.71 A111A1 f c;h. E lain Cher.."', ADDRESS: 109020 N BLANEY AVE .`r. f j.,LIF DATE: 08/1212015 REVIEWED BY: MELISSA Lmi APN: 316 03 045BP#: VALUATION: $50,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Tenant Improvement PRIMARY Commercial Buildin g Alec Per mi 1,ee: PENTAMATION SOLAR -COMM PERMIT TYPE: i USE: (,)Iher' P v nb rruv WORK PG&E SERVICE CENTER - INSTALL 4 N EV CHARGING STATIONS OtPer' E -16c. Imp, SCOPE , ; .. I'�:?tt fi?. /kS 7. f'C'E'; Insp.Fee': Ld i Ii ch. h It, Fe -e: I - due to Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School f c;h. E lain Cher.."', .`r. f j.,LIF " L{C c, 1,ian C�/Zf'C�C fe �. Perinit Fee: I =IldY}Z%7. pe'l mi Fee': Alec Per mi 1,ee: tlrher� �lech. Inv) (,)Iher' P v nb rruv OtPer' E -16c. Imp, , ; .. I'�:?tt fi?. /kS 7. f'C'E'; Insp.Fee': Ld i Ii ch. h It, Fe -e: I - due to Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School . NOTE: This estimate does not include fees other These are based on the preliminaryinformation available and are onl an estimate Contact the Dent or addn'Z into. District, etc.. fees FEE ITEMS Lee Resolution 11-053 E, ff. 711113) FEE QTY/FEE MISC ITEMS $0.00 4 # Alternative Energy System Plan Check Fee: Suppl. PC Fee: Reg. Q OT Q.0 hrs $0.00 $436.00 ICHRGSTA EV Charging Station PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Feer Reg. OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 construction -Tuv Administrative Fee: Work Without Permit? O Yes No $0.00 Select allon-Residential Advanced Planning Fee: $0.00 Building or Structure 0 � 1 rU,,-el Docuyn nlali()n Pees: $14.00 Select an Administrative Item Strom Motion Fee: IBSEISMICO Bldg Stds Commission Fee: 1BCBSC $2.00 TOTAL I♦~ E: $452.00 SUBTOTAT , $16.00 $436100 Revised: 07/02/2015 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: 15080094 10900 N BLANEY AVE (316 03 045) GOWAN CONSTRUCTION 15TH WEST 8 TH STREET OWNER'S NAME: PACIFIC GAS AND ELECTRIC CO OWNER'S PHONE: (408) 279-8787 LICENSED D ONT A TOR'S DECLARATION License Class A Lic. # Contractor GOWAN CONSTRUCTION Date 08/31/2016 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: m. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signatur �; Date 4.28.17 I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: m. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 7. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: m. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date 4.28.17 DATE ISSUED: 10/29/2015 PHONE NO: 209-836-2482 BUILDING PERMIT INFO: BLDG —ELECT —PLUMB MECH _ RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION: PG&E SERVICE CENTER - INSTALL 4 (N) EV CHARGING STATIONS 40 AMPS EA (160 AMPS TOTAL). REVISION #1: CHANGE CONTRACTOR (GOWAN CONSTRUCTION); REVISE CLIPPER CREEK CHARGERS AT CM&O BLDG TO DUAL GFCI OUTLETS (4 TOTAL); RELOCATE CHARGERS AT OPERATIONS TO ENGINEERING/ADMIN BUILDING (2 DUAL AND 1 SINGLE CHARGERS). ISSUED 4.28.17 Sq. Ft Floor Area: I Valuation: $50000.00 APN Number: Occupancy Type: 316 03 045 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by: SEAN HATCH Date: 10/29/2015 All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: 4.28.17 ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505, 25533, and 25534. Owner or authorized agent Date: 4.28.17 CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed CUPERTINO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-322.8 • FAX (408) 777-3333 • building(W-cupertino.or4 PROJECT .ADDRESS / 7 / �. A / APNo J v OWNER NAME /- ate � YHONE � Z70 Gf71 E-MAIL STREET ADDRESS /v o o jam✓, CITY, STATE, <� CONTACT NAME PHONE(Zo, UTO E-MAILGC vc�1� v I I STREET ADDRESS C (�� CITY, STATE, ZIP- {�` 6q0 El OWNER 11OWNER-BUILDER❑ OWNER AGENT CONTRACTOR 11CONTRACTORAGENT ❑ ARCHITECT ❑(ENGINEER ❑ DEVELOPER ❑ IFNA�11 CONTRACTOR NAME /� �. n / p� '� v� LICENSE NUMBER/_ C �y IJP LICENSE�TY BUS. LIC # �z] -7-) d — COMPANY NAME / v k �. z s �✓ a o.+ C_ E-MAIL /_(G ✓1�+7 p .-. V 't we a, G FAX STREET ADDRESSCITY, / 57 ►✓ S STATE, ZJJ:� PHONE ZU� ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX S"FREET ADDRESS CITY, S'FATE, ZIP PHONE USE OF ❑ SFD OI Duplex ❑ Multi -Family STRUCTURE: Commercial PROJECT IN WILDLAND URBAN INTERFACE AREA ❑ Yes No PROJECT IN FLOOD ZONE ❑ Yes )I No / ❑ SOLAR PANELS ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: N.UMBFI1 OF P.ANELS/UNITS: KILOWATTS (COMMERCIAL ONLY): TOTAL VALUATION: �� DESCRIPTION OF WORK I / /C.Lyt,j /O /L RECEIVED BY: By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. 1 have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to nstpx . authorize representatives of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicant/Agent: Date: — Z — SUPPLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY OVER-THE-COUNTER 1 ❑ EXPRESS U U - ❑ STANDARD - ❑ LARGE 0. ❑ MAJOR PVApp_2011.doc revised 03116111 A `J, Z SAFETY. RELIABILITY. INNOVATION. ANTICIPATION. If you're looking for the s most reliable and affordable EVSE charge station, then ClipperCreek is the smart4 choice. In fact, we're the first company in the world to meet the rigid testing standards of Underwriter's Laboratories to earn their UL listing for not one, but six of our EVSE products. So what can we do for you? • Originally founded in 1993 — currently on 12th generation of products • Products in the field for over 10 years s/ /� • Over 3,000 units delivered since 2009 �'/ i • Exclusive manufacturer for BMW Mini and Tesla Level 2 EVSE /�`j • Long history of working closely with industry leading Utilities and Automakers • Smart "reclosure" technology that self -tests, resets and ensures your car will be charged F71CLIPPERCREEK ®R ) ClipperCreek.com OUR FLAGSHIP PRODUCT " UL • UL listed. Outdoor Rated (NEMA 4) enclosure. • Reclosure: Smart software that automatically self -checks unit and resumes charging after minor fault. • Charge Circuit Interruption Device: Ground Fault protection with fully automatic self -check feature that eliminates the need for monthly testing by user. • Service Ground Monitor: Constantly checking for presence of proper safety ground. • External Control Input: Allows external control from smart meter (AMI), billing or load management device. • Cold Load Pickup: Time -delayed and randomized to allow re -energizing of unit following power outages. PRODUCT SPECS • Service Entrance: 208V to 240V - 30 to 100 Amps, single phase, 2 wire w/ground • 17" W x 14" H x 6" D (430mm W x 360mm H x 150mm D) NEMA 4 Construction • Operating Temperatures: -22 F to 122 F 00 C to 50 C) AVAILABLE THIS FALL • Innovative low cost BILLING SYSTEM • SMART GRID Enabled EVSE - tie directly into your AMI Meter CODES, STANDARDS AND RECOMMENDED PRACTICES UL 2202 Charging Station Safety UL 2231 Personal Protection Device (i.e., CCID hardware) UL 1998 Standard for Safety Related Software UL 991 Standard for Tests for Safety -Related Controls Employing Solid -State Devices NEC 625 Electric Vehicle Charge System SAE -11772 Electric Vehicle Conductive Charge Coupler The CS line offers multiple currents that enable you to charge at the highest rate possible, so that vehicles are always fully charged. QUESTION? Call 530-887-1674 or Information@ClipperCreek.net 0 THE Electric Vehicle Charging Station ClipperCreekxom A -chargepoin+ CT4000 Family ChargePoint` Charging Stations The CT4000 is the latest generation of ChargePoint charging Driver Friendly User interface stations. Refined yet rugged, the CT4000 family sets the + Instructional video shows how to use the station industry standard for functionality and aesthetics. A robust cord + Multi -language: English, French, Spanish retraction system comes standard on all CT4000 models to + Touch button interface; works in rain, ice and with gloves eliminate unsightly cords on the ground, and to keep your drivers from having to touch charging cables. + Backed by ChargePoint's world class 24/7/365 driver phone support The CT4000 full motion color LCD display instructs drivers while supporting dynamic updates of custom branded videos and advertisements. The intelligent power sharing feature of the CT4000 doubles the number of parking spaces served by allowing two charging ports to share a single circuit. Sites with single port EV stations can upgrade to dual port stations without requiring additional electrical services. All CT4000 models offer one or two standard SAE J1772'" Level 2 charging ports with locking holsters, each port supplying up to 7.2kW. Available in bollard and wall mount configurations, the CT4000 supports easy installation anywhere. To future proof your invest- ment, all stations are fully software upgradeable over the air. Corporate Branding and Video Advertising + Download full motion color videos to your stations' + Custom replaceable signage to project your brand + Custom "helmet" printing available' Intelligent Power Sharing (patent pending) + Reduced installation and operating costs Dynamically share one 40A circuit between two parking spaces Double the number of parking spaces for a given site's power capacity Upgrade a single port station to dual port with no electrical upgrade Cord Management + Keep charging cords off the ground and out of drivers hands + Standard on all models Ultra -reliable second -generation gravity operated mechanism Flexible over entire -22°F to +122°F product temperature range ' Download fees apply 2 Minimum order quantities apply Energy Measurement and Management + Real-time energy measurement + 15 minute interval recording + Time of Day (TOD) pricing + Load shed by % of runn or to fixed power outpi The standard EV Charging Or sign is easily replaceable witf your branding. The cap of the CT4000 famil also available for custom branding. The 5.7° LCD display provide! full motion charging instructions in a clear and simple format. It also allows station owners to deliver advertising messaging. Driver interaction is supported in any weather by five rugged. back -lit buttons with audio feedback. �ChargePanint CT4000 Family 3.5" (88 mm) 13.7' (347 mm) 9.1" _ (232 mm) 71.3" (1811 mm) 46.7" (1186 mm) 2 chargepoint.com 9.2" --- (233 mm) 71.3" (1810 mm) 13.7" (347 mm) 11.8" (300 mm) 46.6" (1184 mm) Ir 19.0" (483 mm) CT4000 Family Specifications Electrical Input AC Power Input Rating - Standard AC Power Input Rating - Power Sharing Input Power Connections - Standard Input Power Connections - Power Sharing Required Service Panel Breaker - Standard Required Service Panel Breaker - Power Sharing Service Panel GFCI Wiring - Standard Wiring - Power Sharing Station Power -chargepoin+ Single Port Dual Port 208/240VAC 60Hz single phase @ 32A 208/240VAC 60Hz single phase @ 32A x 2 n/a 208/240 VAC 60Hz single phase @ 32A One 40A branch circuit Two independent 40A branch circuits n/a One 40A branch circuit 40A dual pole (non-GFCI type) 40A dual pole (non-GFCI type) x 2 n/a 40A dual pole (non-GFCI type) Do not provide external GFCI as it may conflict with internal GFCI (CCID) 3 -wire (1-1, L2, Earth) 5 -wire (Ll, Ll, L2, L2, Earth) n/a 3 -wire (Ll, L2, Earth) 8W typical (standby), 15W maximum (operation) Electrical Output AC - Standard 7.2kW (240VAC @ 30A) 7.2kW (240VAC @ 30A) x 2 AC - Power Sharing n/a 7.2kW (240VAC @ 30A) x 1 OR 3.8kW (240VAC @ 16A) x 2 Functional Interfaces Connector(s) Type SAE J17721" SAE J1772'" x 2 Charging Cable Length 18' (5.5 meters) 18' (5.5 meters) x 2 Overhead Cable Management System Yes LCD Display 5.7" full color, 640x480, 30fps full motion video, active matrix, UV protected Card Reader ISO 15693,14443, NFC Locking Holster Yes Yes x 2 Safety and Connectivity Features Ground Fault Detection 20mA CCID with auto retry Open Safety Ground Detection Continuously monitors presence of safety (green wire) ground connection Plug -Out Detection Power terminated per SAE J1772'" specifications Power Measurement Accuracy +/- 2% from 2% to full scale (32A) Power Report/Store Interval 15 minute, aligned to hour Local Area Network 2.4 GHz Wi-Fi (802.11 b/g/n) Wide Area Network 3G GSM, 3G CDMA Safety and Operational Ratings Enclosure Rating Type 3R per UL 50E Safety Compliance UL listed for USA and cUL certified for Canada; complies with UL 2594, UL 2231-1, UL 2231-2, and NEC Article 625 Surge Protection 6kV @ 3000A. In geographic areas subject to frequent thunderstorms, supplemental surge protection at the service panel is recommended. EMC Compliance FCC Part 15 Class A Operating Temperature -22°F to 122°F (-30°C to +50°C) Operating Humidity up to 85% @ +50°C (122°F) non -condensing Non -Operating Humidity up to 95% @ +50°C (122°F) non -condensing Terminal Block Temperature Rating 221°F (105°C) Maximum Charging Stations per 802.11 Radio Group 10. Each station must be located within 150 feet "line of sight" of a gateway station. ChargePoint, Inc. reserves the right to alter product offerings and specifications at any time without notice, and is not responsible for typographical or graphical errors that may appear in this document. chargepoint.com 3 ChargePoint CT4000 Family CT4021 Bollard charging station CT4023 Wall Mount charging station —chargepoirl+ ChargePoint, Inc. 1692 Dell Avenue I Campbell, CA 195008-6901 USA +1.408.370.3802 or toll free 877.370.3802 chargepoint.com Ordering Information Specify model number followed by the applicable code(s). The order code sequence is: Model -Options -Warranty Model Single Port Bollard Mount CT4011 Dual Port Bollard Mount CT4021 Single Port Wall Mount CT4013 Dual Port Wall Mount CT4023 Options Integral Gateway Modem - USA -GWI Integral Gateway Modem - Canada -GW2 Warranty Parts Only Extended Warranty - CT4000-EWn' 2, 3, 4, or5year ' Substitute n for the duration of the warranty (2, 3, 4, or 5 year) Order Code Examples orderingIf this the order code is Dual Port Bollard Mount USA Gateway Station CT4021-GW1 Single Port Wall Mount Station with CT4013 5 Year Warranty CT4000-EW5 Dual Port Wall Mount Canada Gateway Station CT4023-GW2 with 2 Year Warranty CT4000-EW2 For More Information Visit chargepoint.com Follow us on Twitter @chargepointnet Like us on Facebook @chargepoint Copyright cr) 2014 ChargePoint, Inc. All rights reserved. CHARGEPOINT is a U.S. registered trademark/service mark, and an EU registered logo mark of ChargePoint, Inc. All other products or services mentioned are the trademarks, service marks, registered trademarks or registered service marks of their respective owners. Sept 2014 PN 73-001020-01-5 Printed on paper made with 100% post -consumer fiber and Listed by Underwriters C @uS 100% certified renewable energy, and processed chlorine free. Laboratories Inc. USTEU ®�^a PCF FiEar