Loading...
B-2016-1812CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 1195 YORKSHIRE CT CUPERTINO, CA 95014-4967 (362 11 009) OWNER'S NAME: JAIN PUNIT AND MEGHANA TRUSTEE OWNER'S PHONE: 408-718-1862 License Class GENERAL ENGINEERING CONTRACTOR Lic. #890895 Contractor St NPOWER CORPORATION SYSTEMS Date 02/28/2017 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: i. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the $Q, performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, ;and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations pert er ino Municipal Code, Section 9.18. Signature �(. Date 6/2/2016 OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's CONTRACTOR: SUNPOWER CORPORATION SYSTEMS RICHMOND, CA 94804 PERMIT NO: B-2016-1812 ISSUED: 04/21/2016 PHONE NO: (941) 720-3850 BUILDING PERMIT INFO: X BLDG ELECT _PLUMB _ MECH X RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION: INSTALL (I) SOLAR ARRAY SYSTEM FLUSH -MOUNTED DIRECTLY TO THE ROOF - 5.56 KW AND 17 MODULES Rev#1 CHANGE WIRE SIZE - ISSUED 6/2/2016 Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. s. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize represelntatives of this city to enter upon the above mentioned property for inspectign purposes. (We) agree to save indemnify and keep harmless the City of Cupertino a�ainst liabilities, judgments, costs, and expenses which may accrue against said�City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date 6/2/201 Sq. Ft Floor Area: I Valuation: $5000.00 APN Number: Occupancy Type: 362 11 009 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. by: ABBY AYENDE RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: 6/2/201 ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health, & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cuperti mucipal Code, Chapter 9.12 and the Health & Safety Code, Se__ ns 25 , 25533, and 25534. Owner or authorized ag Date: 612/2 016 t CONSTRUCTI NLENDIN GENCX I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional CUPERTINO CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255' (408) 777-3228 • FAX (408) 777-3333 - building(a>CuDertino.orq ❑ N,H]U OOIKCTRT IC'TTON�❑-ADDITIONT ❑ ALTER4TI0N / TI L" REVISION / DEFERRtD 3a, e�'Zol(o� I8I2 ORIGD,TAL PERMIT T PROIECT ADDRE SS APN# OWWER N.4hME PHONE E-MAIL I I A��G�\A:v P � ``N Log. , --;Q 5a(p c, STREETADDRESS CITY, STATE, ZIP FAX I \ \ as �tc�c F,s�. « C � C—'D , C A Cr S oI L-A CONTACT NAME PHONE F-h24IL I I 2vocx--AA Q Prc,0 1A� -,-to 2,C)3 �2 t "� � ocx''a •two.@ n 'coc C aM STREET ADDRESS CI TY, STATE, ZIP I FAX ��3 c� s�s� . ;cam CA C?L(E ❑ OVTNER ❑ OWNER -BUILDER ❑ OVN7RAGENT 9 CONTRACTOR ❑ CONTR.4CTORAGENT ❑ ARCHITECT ❑ DNGLNeER ❑ DEVELOPER ❑ ENANT CONTRACTOR NAIME LICENSE NUMBER LICENSE TYPE I I BUS. LIC n ' c�f� C� n RP • �S�t�t cg -G o €, R P°c GO cH 6 Ct 3 CONIPANN NAJiE E-hWL FAX STREET ADDRESS Lenses s CITY, STATE, ZIP ��e , CA , gtrs 3 g PHONE I sx), 20, . %2-Vk A.RCHITECTIENGLnt RNA IF LICENSE NU,6BER BUS. LIC ti\���Ip G�og9� COI`0ANY NAME E-IviiAIL FAX STREET ADDRESS CITY, STATE, ZIP --- PHONE I C .Gs l3ti LCj�;S" AC)b-'S DESCRIPTION OF WORM, EXISTING USE PROPOSED USE CONSTR. TYPE =STORIES L, SE: TYPE OCC. SQ.FT. I V.AiliATION (S) EXISTG NEW FLOOR DEMO TOTAL A,kEA AREA AREA NET AP.EA BATHROOM KITCHEN OTHER RAIODELAREA RENODELAREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECKTORCH ARE', Ur.P AGE AREA: Lj DETACH ❑ ATTACH DV,ELLiNGUNITS: 1S A SECOND UNIT ❑YES SECOND STORY ❑YES � BEING ADDED? E] No ADDITION? []NO PRE :4PPLIC.t T ION ❑ )'=_S IF -S, PROVIDE COPY OF 1S THE BLDG AN ❑ :.S I] -D t• yr TOT. L VALUATION: PLANTTG APPL = ❑ NO PLAN?:ING APPROVAL LETTER EICHLER HOME? ❑ NO ti By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on t e property o\vner's behalf. I have read this application and the information I have provided is cor.ect. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building CO- Q tion. I authorize representatives of Cupeiiino to enter the above-identifled property for inspection purposes. Signature of Applicant/Agent: Date: SLr PLrl\1EI\7TAL ENTOi14A N RE tiit2FD Qxe � " r'i: PLA\ CTiECK TI PE _ x Exp x ROl TI1G SLiP n ❑r ` New SFD or 1 fluitifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance orbuildu7g COLT\TER 3,, BUILDI\G PLA, RE1 IER k x permit for neu+building. F i <. R£SS r !Raw ; :r * a ❑ pr A\\L\G Pr 4 RE] IEii £ fi s Co=ercialBid as: Provide a completed Disclosure 1""' z,mca ❑ PLrLIC\ ORi.�< _ f0_l iI a.}12Za1dOLS 1\/a:erizls are bei --g nced as Daft ofthis O�i=Ct. Copy of Planning .Approval Letter or 1\!eeting with Planning prior to _ submittal of Buiidi-g Permit application. U i,�4JOR r ❑ S\IT R] SE1i ER DISTRICT . ❑. E\�-IRO\1iE'�T.41:HEALTH 'i_':..` Bldg pp_?011.doc revised 05/21/11 CVP'r[iT[N0 �dCIY�55==- SMOKE I CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(ftupertino.org t -_IIuc - — PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R814,2013 CBC Sections 420.6 and 907.2.11.2 where no interior access .for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling, unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. r. Power Supply: In dwelling units with no commercial power supply, alarrn(s), may be solely battery operated:. In existing dwelling units, alarms are permitted to: be solely battery operated where repairs or alterations do y not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be coruzected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s); referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below.. t have read and agree to comply with the termsand! conditions of this statement 19 M S( hatUre. ..... .......... ......._................. -contm(A Nam, 6r ........................... .... .. ........::.,:Lrc��.�..4.a� 19 M CUPERTINth Owner WATER -CONSERVING 'PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITYDEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 950143255 (V8) 777-Z228 • FAX (408) 777-3333 ® WiidingAcupertino.org Address ! �.l t Q d c <AL-­� Cot • Em 1. Is your real property a registered historical site? 1:1 Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. FNo , Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? 0 Yes Civil Code Sections 1101.1 through 1101.8 do not apply. The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. " L�7No Go to Question 3. 3. Is water service permanently disconnected for your building? El Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. W No Go to Question 4. LJ 4. Is your real property built and available for use or occupancy on or before January 1, 1994? 0` No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. EYes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. 5. Please check ONE of the following: My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). " 0 My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water= conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). El My property is a commercial real property. See Civil Code 'Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). 1, as the owner or owner's agent of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the table on the following page. Owner or Owner Agent's Signature. E _ � / Date: r .z j., 1 b I' Unon comoletina and sinning this Certificate, please return it to the in order to final your building permit. SB40'72015.docrevised 08126115 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB4072015.doc revised 08126115 Non -Compliant Water -Conserving Plumbing Fixture Plumbing Fixturel (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usa a/Flow Rate Fixture Type Water Usage 2013 CPC Ch. 4 2013 CPC Ch. 4 . 2013 CPC Ch. 4 /Flow Rate .2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single -Family Multi -Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 Gallons/flush 0.5 gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets - Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per,minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB4072015.doc revised 08126115 S ' CODE INFORMATION beLn v m o o f € W a, LL,s f'— APPLICABLE CODES, LAWS AND REGULATIONS (Mnz K mvaJ �0S LAR INDIVIDUAL PERMIT PACKAGE2013 CALIFORNIA RESIDENTIAL CODE (CRC) mo# p � � W 2013 CALIFORNIA BUILDING CODE (CBC) °O Z ° N dab c • ~ m � 2013 CALIFORNIA FIRE CODE (CFC) Z a 0 u =� ����®� � .2013 CALIFORNIA ELECTRICAL CODE (CEC) � ° _ _ a lJ MEGHANA AIN _- J o�� THE INSTALLATION OF THE PV SYSTEM in u a SHALL CONFORM -TO THE REQUIREMENTS OFTHE 2013 CBC AND 2013 CEC, ARTICLE 690 AND ANY OTHER APPLICABLE 5.56kW GRID TIED -PHOTOVOLTAIC SYSTEM ARTICLES OR STANDARDS. INSTALLATION SHALL BE PROVIDED BY A CALIFORNIA r . ,t LICENSED CONTRACTOR(B, C-46, OR C-� �;r• ,�5� d R TI N 0 ffel . epartment VICINITY2 2016 1195 YORKSHIRE CT FROJECTLOCAn°"CJE COMPLIANCE ._, i�` CUPERTINO, CALIFORNIA 95014oe� =gym 1 F pP�� N1NG p�P`�R° U o ISN P RT L0 a GUP j �� Z b Q Q a ZQ Y J J a aQ Q ABBREVIATIONS SYMBOLS SHEET INDEX = ° LU o U 0W O w rn z 5 v @ At ELEC. Electrical MAX. Maximum SB Starbucks W z A.B. Anchor Boll EO Electrical Outlet M.D.F. Medium Density Fiberboard S.C. Solid Core Seat Cover ( d E.P.B. Electrical Panel Board MECH. Mechanical / SOLAR ARCHITECTURAL DRAWINGS A.C.T. Acoustic Ceiling Tile SCN ED, Schedule A.D. Area Drain EQ. Equal MEMB, Membrane SECT. Section U ADJ. Adjacent, Adjustable EQUIP. Equipment MEZZ. Mezzanine SSee Electrical Drawings �[ O A.F.F. Above Finish Floor E.W.C. Electric Water Cooler MFR. Manufacturer S.E.D.FD Smoke Fire Damper NEW FINISH GRADE SOLAR -AO COVER SHEET i0 N AL. Aluminum EXIST. Existing MIN. Minimum SHT. Sheet ti� ( ) A.T.C. Acoustic Tile CeilingEXP. Expansion MIR. Mirror DRAWING NUMBER GROUP DRAWN ®45' In NUMBER DISCIPLINE PREFIX sZ FIRE STANDPIPE CABINET 4 SIM. Similar EXISTING GRADE (SHOWN SOLAR -Al ARRAY LAYOUT EXP. Ji. Expansion Joint MISC. Miscellaneous S.M.D. See Mechanical Drawings F.S.C. X. HORIZONTALLY BB. Bulletin Board EX7, Exterior M.O. Masonry Opening g ) SOLAR -A2 ROOF 1 STRUCTURAL DETAIL BD. Board S.M.S. Sheet Metol Screw WALL HUNG CABINETS OR MOD. Module BETW. Between F.D. Floor Drain SP Sprinkler SHELVES M.S. Machine Screw REVISION CLOUD AROUND m BLKG. Blocking F.E. Fire Extinguisher S.P.D. See Plumbing Drawings PROPERTY LINE MTD. Mounted REVISION BM. Beam F.E.C. Fire Extinguisher Cabinet MTL. Metal S.S. Stainless Steel A. COUNTERTOP m B.O. Bottom 01 F.H. Flat Head S.S.D. See Structural Drawings o i BOT. Bottom F.H.C. Fire Hose Cabinet CN) New S.T.S. Self—Drilling, Self—Topping N.I.C. Not In Contract A� B.P. Backing Plate FIN. Finish Sheet Metol Screw MATCH LINE. SHADED PORTION OWNER FURNISHED ITEMS < FLR. Floor NO. Number STD. Standard TOP OF WALL < BRW. Bearing NOM. Nominal IS THE SIDE CONSIDERED NJ C. (NOT IN CONTRACT) O BTWN. Between FLUOR. Fluorescent N.T.S. Not To Scale m• Steel CAB. Cabinet F.O. Face Of STRUCT. Structural N F.O.S. Face 01 Stud SUSP. Suspended g Z CER. Ceramic O.A.D. Overall Dimension. WORK POINT, CONTROL POINT �3 O F.O.W. Face 01 Wall TB. Tack Board ACCESS PANEL t. TOP OF CURB CH Coal Hook O.C. On Center. YYY G F.R. Fire Resistant 11 DATUM POINT ® SOLAR STRUCTURAL DRAWINGS C.J. Control Joint O.D. Outside Diameter T.0. Thick N O F.S. Full Size CL Center Line DPNG. Opening T.O. Top 01 ,.., a FURR. Furring CL. Closet OPP. Opposite T.O.C. Top 01 Concrete � =SLG. Ceiling �T• Future O.F.C.I. Owner Furnished/ T.O.S. Top Of Steel /�_ SECTION . SOLAR -S1-S2 MOUNTING DETAILS u' w ,'CLR. Clear GA. Gauge Contractor Installed TSO Telecommunication SECTION IDENTIFICATION DIMENSION LINES ty' TOP OF PAVEMENT •C.M.U. Concrete Masonry Unil GALV. Galvonized O.F.O.I. Owner Furnished/ Service Outlet �'t SHEET WHERE SECTION IS DRAWN o u SOLAR -S3 STRUCTURAL CALCULATIONS COL. Column G.B. Grab Bar Owner Installed TTD Toilet Tissue Dispenser -CONS. Concrete G.D. Garbage Disposal O.F.V.I. Owner Furnished - TYP. Typical DETAIL SOLAR-S4–S6 INVISMOUNT DATA & SPECIFICATIONS F CONST. Construction G.W.B. Gypsum Wallboard Vendor Installed 3 CENTERLINE OF COLUMN OR CONT. Continuous GYP. BD. Gypsum Wallboard O.H. Oval Head U.O.N. Unless Otherwise Noted Ay l DETAIL IDENTIWHERE DETIONAIL STUD OFFSET FACE 9 SHEEP WHERE DETAIL IS DRAWN C.R. Cold Rolle O/ Over UP. Upper C.R. Cold Rolled H.B. Hose Bibb � ^ ,C T. Ceramic Tile H.C. Hollow Core PAD Powder Actuated Device V.C.T. Vinyl Composition Tile C INTERIOR ELEVATION(S) CTR Counter HDWD. Hardwood PB Push Button Door Operator VEN. Veneer —� O.C. P. LAM. Plastic Laminate ELEVATION IDENTIFICATION FACE OF CONCRETE ALIGN FACE OPPORTUNITY SPRI- Fremont ,CTSDBL. Countersink H.M. Hollow Metal VER. Verify 4 UNFOLD ELEVATIONS CLOCKWISE. HR. Hour IL Property Line B :DBL. Double PL. Plate VEST. Vestibule AS,I NO ARROWS MEANS ELEVATION . H.R. Hot Rolled V.I.F. Verify In Field NOT SHOWN. ',-DCA. Drilled Concrete Anchor Y ) PROJECT D-0053465 HT. Height PLV. Plywood y,C. VerifyWith Casework A SHEET WHERE ELEVATION Is .{)ET. Detail PLYWD. PI wood DRAWN Q.D.F. Drinking Fountain y V.W.C. Vinyl Wall Covering —� Rox. EXISTING WALL OR PARTITION SOLAR ELECTRICAL DRAWINGS g I.D. Inside Diameter FT. Paint �� DIA. Diameter I.F. Inside Face P.T. Pressure Treated FACE OF FINISH TO REMAIN DIM. Dimension W/ With DATE DRAWN Os -31-2016 INS. Insulation PTD. Painted W.C. Wall Covering DISP. Dispenser INT. Interior M. Partition ON. Down INTER. Intermediate WD. Wood 'fit �R" ^ SOLAR -E1 ELECTRICAL SINGLE LINE DIAGRAM & DRAWN BY HLLuvloso DR. Door Q.T. Quarry Tile W.P. Waterproof 1'�t FINISH FACE TO FINISH FACE ` EXISTING DOOR TO REMAIN SPECIFICATIONS DSP 'Door Side Panel INTCM Intercom QTY, Quantity W.R. Water Resistant Y DATE CHECKED 05-31-2016 DTL. Detail JAN. Janitor W.S. wood screw SOLAR -E2 ELECTRICAL CALCULATIONS & DETAILS DWG. Drawing JST. Joist RAD. Radius WR Wosle Receptacle y..r f sE) Existing JT. Joint R.D. Roof Drain PLUMBING OR PIPE CHASE ALIGN SOLAR -E3 E10 LECTRICAL DATA &SPECIFICATIONS CHECKED BY APATEL Each LCB. Liquid Chalk Board RE: Refer To WALL (FACE OF STUD U.O.N.) Ext. Insulation Finish System LAM. Laminated REQD. Required �?, SOLA Ell TRING DIAGRAM SHEET Q Expansion Joint LTV. Level RES. Resilient VOLAR -AO Elevation R.H. Resilient LT. WT. Light Weight R.H. Round Head T L.N. Liquid Nitrogen Dff&VAY -� I 56'-9" \ GARAGE EXTERNAL RUN (E) ROOF VENT ALONG THE ROOF /-(TYP•) THEN DOWN THE WALL TOINVERTER OO rm NOTE: LEGEND pC 1SKY LIGHT da (TYP.) u O u ROOF 1: 17 MODULES • • • \ 0. o W W O 0 O, N � o > } 0+ _- lMqll p ]UNCTION BOX + I t '•7t•1• / 17i It it tyi + / I 5:12 (230) -psi. i:jr t-t.{'�,.,Y_+_ �,•��' tiN�r t. ,,, Ll Z uo W 1.3 �cl 'i2:� .;�.it«,Y.+ �{:t. _ H 3' (E) CHIMNEY HT: IT/ o o z ROOF ACCESS POINT / (E) POOL (E) TREE HT: t48' LLI CL a , o o u in n uLq g 5.56 kW M O V J E LTi OPPORTUNITY 52'-6" AC DISCONNECT / 40'-1 1 " o v u PROSECT D-0053465 STORY HOME TYPE 2 - STORY DATE DRAWN 139' 0 U 0 NOTE: LEGEND pC Lu da < u O u F 'T Ln b 0. o W W O 0 O, N � o > } 0+ ^ O p ]UNCTION BOX HE-VIHE-VIS Y � -i Qa0 Ce U Z uo W In g H �cl W W ! 0N# `F- o o z CONDUIT LLI CL a , o o u uLq g 5.56 kW M O V J E LTi OPPORTUNITY acD AC DISCONNECT ROOF TYPE o v u PROSECT D-0053465 STORY HOME TYPE 2 - STORY DATE DRAWN 05-31-2016 SYSTEM ORIENTATION �RVfR INVERTER + ,: 4`` `T.-4 -.. f E I N O ROOF PITCH 5:12(230) 9 O I � .�1 )�Y�,c.� i!diDe n g partment CONSUMPTION MONITORING NO CHECKED BY APATEL NEW SERVICE PL UTILITY METERI` -q UN2 LQ9� SCALE 1/16" = V-0" BUS BAR RATING 100 A - MAIN PANEL SWAP OR CODE COMPLIANCE 1$0 REVIEVVED SOLAR -A1 - PROPERTY LINE Revie d By: =� 3' WIDE ACCESS PATH 0 U 0 NOTE: w Lu V7 < u O u a v M 0. o Lu ^ O �� C) a Q z = Y � -i Qa0 Ce U > �cl W W i �Z `F- r�,Q LLI CL uLq g 5.56 kW LTi NOTE: 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED ON ACTUAL SITE CONDITION AND MEASUREMENTS. a v 2. WILL BE INSTALLING 2" FROM THE EAVE. 3. HO NEED TO REMOVE 5 SOLAR THERMAL PANELS AND REPAIR ROOF, NOT SUNPOWER SCOPE. 4. MAIN SERVICE PANEL SWAP REQUIRED. m z 0 U) o '" w 0 W U z CONTRACT MODULE AND QUANTITY INVERTER TYPE AND QUANTITY SPR -E20-327 (17) SBSOOOTL-US-22 (240VAC)(1) SYSTEM SIZE 5.56 kW OPPORTUNITY SPRI- Fremont ROOF TYPE COMPOSITION PROSECT D-0053465 STORY HOME TYPE 2 - STORY DATE DRAWN 05-31-2016 SYSTEM ORIENTATION 210 °SW DRAWN BY HLLUVIOSO ROOF PITCH 5:12(230) 9 O DATE CHECKED 05-31-2016 CONSUMPTION MONITORING NO CHECKED BY APATEL MAIN BREAKER RATING 100 A ----------------- SCALE 1/16" = V-0" BUS BAR RATING 100 A - MAIN PANEL SWAP SHEET 1$0 SOLAR -A1 CENTERFED MAIN BREAKER NO , I FIG.A: MODULE PLACEMENT AND RAFTER FRAMING DETAIL - ROOF 1 TRUSS SIZE AND SI 2"x4"® COMPOSITE SHINGLE, 1 LAYER Assumed Vintage Nominal Size tie Li- N x � Non -Tile Roof /! Jbl� ;4+. ; / Tile Root`' LEGEND W W 0 N W o o � W m N 16" O.C. 24" O.C. 32" O.C. 16" O.C. 24" O.C. 32" O.C. — — EXISTING RAFTER 1%"x3Y." N a o W 3 a 8'-0" U o u Z U O 2 o ^ `" • ROOF ATTACHMENT 2"x6" 1%"x5'/:" Z m z - W a�QOU �ax 9'-6" zo ------ RAIL N " o x x Q> LU �ce = a v z v . a ® CHIMNEY Q ROOF VENT p A� PE�T��o Q �C T1iP1P liir/ UU "r- - 8'-6" g Department r (ID%AC ESS � D ce i_T XNi� 14'-0" 11'-3" : =yA9A! 0 Z 2016 9'4" REVIEWED FOF CODE COMPLIANCE Awa Reviewed By: w4 __ TRUSS SIZE AND SI 2"x4"® COMPOSITE SHINGLE, 1 LAYER Assumed Vintage Nominal Size Actual Size D-0053465 Non -Tile Roof /! Jbl� ;4+. ; / Tile Root`' w Rafter Spacing z 16" O.C. 24" O.C. 32" O.C. 16" O.C. 24" O.C. 32" O.C. Post -1960 211x4" 1%"x3Y." 9'-10" 8'-0" U o 6'-11" 5'-6" 2"x6" 1%"x5'/:" 14'-4" 11'-9" 9'-6" zo 10'-2" � � N " 2"0" Q> LU �ce ce_j 1 1 15'-9" Q ° _� 0 a 2"x4" 1'/4"x3Y44" Q n= �QQ UU 10'-3" 8'-6" 6'-9" = w 0 > � D ce 17'-0" 14'-0" 11'-3" Ln Z j H 9'4" 0Q1 2"x8" Awa L9 - 14'-6" 19'-0" U a0 gW tD U) cn Lo Ln ., v) Z�o Ln 210 m 0 FIG.B: STRUCTURAL RAFTER FRAMING DETAIL (NTS) FIG.C: ROOF RAFTER MAX HORIZONTAL SPAN PER CALIFORNIA SOLAR PERMITTING GUIDEBOOK 2015 (NTS) o TRUSS SIZE AND SI 2"x4"® COMPOSITE SHINGLE, 1 LAYER Assumed Vintage Nominal Size Actual Size D-0053465 Non -Tile Roof 05-31-2016 Tile Root`' HLLUVIOSO Rafter Spacing 05-31-2016 16" O.C. 24" O.C. 32" O.C. 16" O.C. 24" O.C. 32" O.C. Post -1960 211x4" 1%"x3Y." 9'-10" 8'-0" 6'-6" 8'-6" 6'-11" 5'-6" 2"x6" 1%"x5'/:" 14'-4" 11'-9" 9'-6" 12'-5" 10'-2" 8'-0" 2"0" 1%"x7'/<" 18'-2" 14'-10" 12'-0" 15'-9" 12'-10" 10'-3" Pre -1960 2"x4" 1'/4"x3Y44" 11'-3" 9'-9" 7'-9" 10'-3" 8'-6" 6'-9" 211x6" 1Y."x5'/4" 17'-0" 14'-0" 11'-3" 14'-9" 12'-0" 9'4" 2"x8" 1'/4"x7Y44" 22'-3" 18'-0" 14'-6" 19'-0" 15'-6" 12'-6" NOTES: JOIST 1. THE SITE AUDITOR HAS VERIFIED THAT ROOF STRUCTURE IS STRUCTURALLY SOUND WITHOUT SIGNS OF ALTERATIONS OR SIGNIFICANT STRUCTURAL DETERIORATION OR SAGGING. 2. MEASURED HORIZONTAL SPAN IS LESS THAN TABLE 1 SPAN ABOVE, THEREFORE NO STRUCTURAL MODIFICATION IS REQUIRED. 3. MAXIMUM ATTACHMENT SPACING IS 6' ON CENTER, PLEASE REFER TO SOLAR -S1 SHEET. Z d U 0 OPPORTUNITY SPRI- Fremont PROJECT D-0053465 DATE DRAWN 05-31-2016 DRAWN BY HLLUVIOSO DATE CHECKED 05-31-2016 CHECKED BY APATEL SCALE i/pn _ i' -OH SHEET SOLAR -A2 m RISK CATEGORY II, V = 110 MPH BASIC WIND SPEED, EXPOSURE C, 0 PSF GROUND SNOW LOAD, Ss = 2.Og HEX CAP—/ MAX MAX MAX MAX f SPACING CANTILEVER UPLIFT DOWNFORCE W W o o 25 psf 28 psf ZONE 1 72" 36" 390 lb 444 lb ZONE 2 36" 18" 46 psf 28 psf o 360 lb 222 lb ZONE 3 30" 15" 73 psf 28 psf Z K p O 4751b 1851b • NOTE: POINT LOADS SHOWN IN TABLE ABOVE (Ib) ARE FOR EACH ATTACHMENT ASSUMING MAX SPACING SHOWN IS USED. • LOADS SHOWN ARE LRFD LOADS. INVISIMOUNT RAIL a • 14- 1 VA VA v tj 14" 1, 14" ' 96 CELL MODULE 72 CELL MODULE •INVISIMOUNT RAILS SHALL BE POSITIONED IN THE NON -CROSS HATCHED REGIONS FIGURE 2: INVISIMOUNT MOUNTING CLAMP POSITIONING DETAILS PV MODULE MID PV MODULE CUPIRTINU ;dui{ding 1pepartment =D FOR Reviewed k � J 2016 DE COMPLIANCE W' v v c u u g Lu REFER TO SUMMARY TABLE REFER TO SUMMARY TABLE 00} FOR MAX SPAN AND CANTILEVER FOR MAX SPAN AND CANTILEVER I > (E) TRUSS I HEX CAP U o � L FOOTi SHINGLE ON TOP OF � FLASHING INVISIMOUNT RAILS Z J Q (2) PER MODULE �� \���\��� \��� \��� .�\��� \��� \\\��\��� �.� \ \� \\ \\�� �������� \\\� \\�� ��� I Q Lu Z O N H FLASHING I O Ln 0 O M w SHOE ASSEMBLY Q O O Q W z SUNPOWER MODULE (TYP.) COMPOSITION SHINGLES—"Z O U a', P I I 5/16" X 4- S.S. LAG BOLT WITH 5/16" WASHER ®CENTER TYP. L O E _ 2 1/2" MIN. EMBEDMENT INTO TRUSS. PRE—DRILL REQUIRED. UJ z ROOF ATTACHMENTS (TYP.) I (E) TRUSS(DOUGLAS FIR OR EQUAL) w _ _ (SEE FIGURE 2, 3 Sc 4) _ _ _ _ _ .. 0 a o � U N ____ 0.5- MIN Ln o \} i FIGURE 3: INVISIMOUNT ROOF ATTACHMENT DETAILS @ TRUSSES LTJ = I = =31P= _ 4 ` \ I END CLAMP w N o / '>•WEIGHT OF INSTALLED ARRAY: 3.5 PSF •STAGGER ATTACHMENTS WHEREVER POSSIBLE — MID CLAMP w v: cn 3 n v� O in I ? FIGURE 1: PLAN VIEW, TYPICAL ARRAY LAYOUT L INVISIMOUNT RAIL MAX CANTILEVER MID CLAMP PER SUMMARY TABLE END CLAMP L FOOT END CAP PV MODULE W PV MODULE SHINGLES 'I--- SHINGLE ON TOP OF FLASHING '9.'_ SHINGLE ON TOP OF FOOT HEX CAP—/ 15/32- ROOF `—HEX CAP f (3) 16d SINKER NAIL OR W W o o OPPORTUNITY SPRI- Fremont TOE NAIL ON EACH END In o (3) 16d SINKER NAIL °° D-0053465 TRUSS5/16- Z K p O NOTE: 4-X6" FLAT BLOCKING p O a w S t� A L.V CENTER TYP. 0 m ATTACHMENT POINT IS REQUIRED 2 1/2MIN. EMBEDMENT m z .. W HLLUVIOSO BETWEEN TRUSSES IN ORDER TO `<p1� 2 1/2" MIN. EMBEDMENT Z K O Q my DATE CHECKED 05-31-2016 FIG. 1 SUMMARY TABLE. = = CHECKED BY APA7EL p K u v, u €o CUPIRTINU ;dui{ding 1pepartment =D FOR Reviewed k � J 2016 DE COMPLIANCE W' v v c u u g Lu REFER TO SUMMARY TABLE REFER TO SUMMARY TABLE 00} FOR MAX SPAN AND CANTILEVER FOR MAX SPAN AND CANTILEVER I > (E) TRUSS I HEX CAP U o � L FOOTi SHINGLE ON TOP OF � FLASHING INVISIMOUNT RAILS Z J Q (2) PER MODULE �� \���\��� \��� \��� .�\��� \��� \\\��\��� �.� \ \� \\ \\�� �������� \\\� \\�� ��� I Q Lu Z O N H FLASHING I O Ln 0 O M w SHOE ASSEMBLY Q O O Q W z SUNPOWER MODULE (TYP.) COMPOSITION SHINGLES—"Z O U a', P I I 5/16" X 4- S.S. LAG BOLT WITH 5/16" WASHER ®CENTER TYP. L O E _ 2 1/2" MIN. EMBEDMENT INTO TRUSS. PRE—DRILL REQUIRED. UJ z ROOF ATTACHMENTS (TYP.) I (E) TRUSS(DOUGLAS FIR OR EQUAL) w _ _ (SEE FIGURE 2, 3 Sc 4) _ _ _ _ _ .. 0 a o � U N ____ 0.5- MIN Ln o \} i FIGURE 3: INVISIMOUNT ROOF ATTACHMENT DETAILS @ TRUSSES LTJ = I = =31P= _ 4 ` \ I END CLAMP w N o / '>•WEIGHT OF INSTALLED ARRAY: 3.5 PSF •STAGGER ATTACHMENTS WHEREVER POSSIBLE — MID CLAMP w v: cn 3 n v� O in I ? FIGURE 1: PLAN VIEW, TYPICAL ARRAY LAYOUT L INVISIMOUNT RAIL MAX CANTILEVER MID CLAMP PER SUMMARY TABLE END CLAMP L FOOT END CAP PV MODULE W PV MODULE SHINGLES 'I--- SHINGLE ON TOP OF FLASHING '9.'_ SHINGLE ON TOP OF FOOT FIGURE 4: INVISIMOUNT ROOF ATTACHMENT DETAILS @ BLOCKED LOCATIONS SOLAR -S1 HEX CAP—/ 15/32- ROOF `—HEX CAP (3) 16d SINKER NAIL OR SHEATHING MINIMUM OPPORTUNITY SPRI- Fremont TOE NAIL ON EACH END (3) 16d SINKER NAIL PROJECT D-0053465 TRUSS5/16- X 4- S.S. LAG BOLT OR OE NAIL ON EACH NOTE: 4-X6" FLAT BLOCKING WITH 5/16- WASHER 5/16" X 4" S.S. LAG BOLT END DATE DRAWN 05-31-2016 ONLY REQUIRED WHERE.O CENTER TYP. WITH 5/16- WASHER TRUSS ATTACHMENT POINT IS REQUIRED 2 1/2MIN. EMBEDMENT 0 CENTER TYP. DRAWN BY HLLUVIOSO BETWEEN TRUSSES IN ORDER TO INTO BLOCKING. 2 1/2" MIN. EMBEDMENT MEET MAX CANTILEVER SHOWN IN PRE—DRILL REQUIRED. INTO TRUSS. DATE CHECKED 05-31-2016 FIG. 1 SUMMARY TABLE. PRE—DRILL REQUIRED. CHECKED BY APA7EL FIGURE 4: INVISIMOUNT ROOF ATTACHMENT DETAILS @ BLOCKED LOCATIONS SOLAR -S1 1 DESIGN PARAMETERS WIND LOADS RISK CATEGORY: II EXPOSURE: B OR C MAXIMUM WIND SPEED PER IBC 2012, V: 110 MPH MAXIMUM ROOF HEIGHT, H: 40 FT MAXIMUM ROOF SLOPE: 12:12 MAXIMUM LEAST HORIZONTAL DIMENSION OF BUILDING, L: 50 FT TOPOGRAPHIC FACTOR, kzt: 1.0 WIND DIRECTIONALITY FACTOR, kd: 0.85 VELOCITY PRESSURE EXPOSURE COEFFICIENT, kh: 1.04 INTERNAL PRESSURE COEFFICIENT, GCPi: 0.0 SNOW LOADS MAXIMUM GROUND SNOW LOAD, pg: 0 PSF EXPOSURE FACTOR, Ce: 0.9 (FULLY EXPOSED) THERMAL FACTOR, Ct: 1.2 (UNHEATED AND OPEN AIR STRUCTURES) SLOPE FACTOR, Cs: PER FIGURE 7-2t (UNOBSTRUCTED SLIPPERY SURFACE) SNOW IMPORTANCE FACTOR, Is: 1.0 SEISMIC LOADS SHORT PERIOD SPECTRAL ACCELERATION, Ss: 2.Og SITE COEFFICIENT, Fa: 1.0 COMPONENT AMPLIFICATION FACTOR, ap: 1.0 SEISMIC COMPONENT IMPORTANCE FACTOR, Ip: 1.0 ' COMPONENT RESPONSE MODIFICATION FACTOR, RD: 1.5 LL SITE CLASS: D LEGEND _ ❑INTERIOR ZONES Zt ZONE 1 W END ZONES t5 - I I ZONE 2 ■CORNER ZONES dui g D©partment `r ' (ding I ZONE 3 FIGURE A: ROOF ZONES PER ASCE 7-10 FLAT ROOF be Zt cjl , I W 05-31-2016 t5 - I I is a -f TINO 05-31-2016 dui g D©partment `r ' (ding I GABLE ROOF (70< E):5 450) y ��� '° IF� 0 2 2016 111 II/ II z FOR CODE COMPLIANCE REVIEWED S - Reviewed By: W4 FLAT ROOF HIP ROOF (70< 9:5 270) Zt cjl , I DATE DRAWN 05-31-2016 t5 - I I is DATE CHECKED 05-31-2016 GABLE ROOF (6 <_ 70) GABLE ROOF (70< E):5 450) / II II/ II z S - REVISIulo"111'm # � x W N } a, U) � < rn z o G UJ z0 Q0 U- Q = 0 U U' w Lr) O ~ F o a D_'W � a ?� U .Y Ln Ln z 0 F u N O N M W p W z CL z V) =) 0 OPPORTUNITY SPRI- Fremont PROJECT D-0053465 DATE DRAWN 05-31-2016 DRAWN BY HLLUVIOSO DATE CHECKED 05-31-2016 CHECKED BY APATEL SOLAR -S2 be. f::)V Ln e 11 •!i I'� �� �j."'..�4i'a.yy. '•''FK LU W o o U, m .0 m Ifl F Q . Department GO u •'.s�:tJ. is - ZO U 'g � ..? � N E ri e �} {c 2016 .. a m W o a c g Load Calculation Parameters Las Bolt StrengthREVIEWED FOR CODE COMPLIANCE � a v J a s Rail tributary width 2.6 ft NDS LRFD Reviewed �/ Ce a K U Flat roof snow load pf 7.6 psf By: .. � Wind velocity pressure qh 27 psf Service Loads Bolt diameter, D = 0.3125 inch Dead Load pd 3.38 psf Specific gravity, G = 0.49 (Douglas Fir or equal) Sloped Roof Snow Load ps 7.6 psf Withdrawal value, W = 258 Ib; NDS Table 11.2A Wind Load Upward Zone 1 pw_zonel -27.48 psf Load duration factor, Cd = 1 ; Section 10.3.2 (LRFD design) Wind Load Upward Zone 2 Wind Load Upward Zone 3 pw_zone2 px_zone3 -49.46 psf -76.94 psf Wet service factor, Cm = 1 ; Section 10.3.3 (wood in continuously dry condifloo Wind Load Downward pw down 25 psf Temperature factor, Ct = 1 ; Section 10.3.4 (no sustained temp > 1007) Seismic Load Fp 3.6 End grain factor, Ceg = 1 ; Section 11.5.2 (no end grain) Seismic Load Fp-upper-limit 1.4 Toe -Nail factor, Ctn = 1 ; Section 11.5.4 (no toe nail) Seismic Load Fp_lower_limit 7.2 Seismic Load Fp_egn 3.6 Format conversion factor, Kf = 3.32 ;Table N1 (Connections) Load Combinations Resistance factor, ePz = 0.65 ; Table N2 (Connections) 1.41) Combo 1 10 plf Time effect factor, X = 1 ; Table N3 (Wind/Seismic) 1.2D+1.6S+0.5W Combo 2 57 pif 1.2D+0.5S+1.OW Combo 3 74 plf 0.9D+1.OW Combo 4 (Zone 1) -65.43 plf W' (per inch of thread penetration) = 557.28 Ib; Table 10.3.1 0.9D+1.OW Combo 5 (Zone 2) -119.91 plf 0.9D+1.OW Combo 6 (Zone 3) -190.11 plf Lu 1.2D+1.OE+0.2S Combo 11 15 plf 1.41) Combo 7 7.4 plf inin 1.2D+1.6S Combo 8 14 plf o Ln Z 0- 1.2D+0.5S 0.91) Combo 9 8.5 plf z J LU 0 Z g Combo 10 4.8 plf Q > 1.2D+1.OE+0.2S Combo 12 14 pif r -t O Ce OLL N Worst Case Uplift Zone 1 WCzonel 65 pif Q p c=n o a Worst Case Uplift Zone 2 WCzone2 120 plf Q a a w Worst Case Uplift Zone 3 WCzone3 190- plf 2 0 U oc J Worst Case Downward WCdown 74 plf w L, O in 5 Worst Case Seismic Demand WCeq 15 plf Worst Case Shear for Uplift Cases WCshear_up 4.8 plf -- - ------ -- --- -- - - Worst Case Shear for Downward Cases WCshear down 14 plf y c� 0.0 tn Worst Case Shear for Seismic Cases WCshear eq 14 pif Y U Roof Wind Zone Dimensions to x Width of edge and corner zones io a 5 ft Ln .Maximum Allowable Spacing of Maximum allowable attachment spacing, Lallowed zonal 72 in 8 m = Maximum allowable attachment spacing, Lallowed zone2 36 in Maximum allowable attachment spacing, Lallowed zone3 30 in ° E Maximum allowable cantilever, zone 1 Cantileverzonel 36 in a Maximum allowable cantilever, zone 2 Cantileverzone2 18 in ° Ir Maximum allowable cantilever, zone 3 Cantileverzone3 15 in Z Rail Bending o Rail Bending Up Strength Mn 548 Ib -ft Rail Bending Down Strength -rail -up Mn_rail 580 Ib -ft > L -Foot _down LU 0 L -Foot Tension Strength Tn_L-Foot 510 Ib _ L -Foot Compression Strength Cn_L-Foot 999 Ib o L -Foot Shear Strength Vn_L-Foot 195 Ib OPPORTUNITY SPRI- Fremont PROJECT D-0053465 -- _- - _ - DATE DRAWN 05-31-2016 DRAWN BY HLLUVIOSO - i� DATE CHECKED 05-31-2016 CHECKED BY APATEL FIGURE B: INVISIMOUNT STRUCTURAL CALCULATION FIGURE C: LAG BOLT STRUCTURAL CALCULATION SHEET SOLAR -$3 V) f a m �b LUw o 0 m M 3 V n 0 r r rn rn in a 1q0 Z U O w F J/yy,,FlF77'J�J }a R OON �i O O 0Ln En z Z $b ® ® V L0� F- m a 01 u 11 August 2014= , SunPower Invisimount Design Tool � o u * M A F F E I M A F F E I Structural Calculations �o STRUCTURAL ENGINEERING STRUCTURAL ENGINEERING Paget rtipE p N 8u ding Department 11 August 2014 • Performed. independent calculations for six example project sites, plus spot checks of othe • potential project conditions, to compare to the structural design loads and load combination'; s� i 'tool r ,'3 0 2 2016 Guillaume Carr6 calculated by the to act on the arrays, rails, and attachments to the roof structure. For I SunPower Corporation of the examples that we checked, the loads and load combinations calculated by the tool are 1414 Harbour Way South consistent with our independent calculations in accordance with the structural desigt�,E VI~_liri^D ; R CODE COMPLIANCE Richmond, CA 94804 c1 standard ASCE 7-10 Minimum Design Loads for Buildings and Other Structures. Revlevj :d By.- • Performed independent calculations for ten example project sites, plus spot checks of other Subject: SunPower Invisimount Design Tool potential project conditions, to compare to the bill of materials estimated by the tool. For all Structural Calculations of the examples that we checked, the quantities of parts estimated by the tool are the same as the quantities from our independent calculations, or within a reasonable tolerance. The Dear Guillaume, attached "Engineering Basis of Calculations" describes the procedure that the tool uses for estimating the bill of materials. w Per your request, we are pleased to present the findings from our review and testing ofLn z SunPower's Invisimount Design Tool, an online tool that: SUMMARY OF FINDINGS • Evaluates structural design loads on SunPower Invisimount solar arrays To an extent consistent with the scope of our review, our professional opinion is that the F Ln rn U LL • Evaluates the maximum allowable spacing of attachments of the system to the roof to resist Invisimount Design Tool calculates structural design loads on the solar arrays, and maximum � o C z w design loads allowable spacing of attachments to the roof structure, that are consistent with the standards and ^ o Ce o I. M � • Estimates the bill of materials for specific projects to assist with ordering parts from procedures described in the attached "Engineering Basis of Calculations," including ASCE 7-10 Q o Ln u_ o as SunPower Minitnum Design Loads for Buildings and Other Structures, the 2012 International Building Q a 0 a w Code, and the 2013 California Building Code. w o o SCOPE a o OF THE TOOL w z ~ V) Invisimount by SunPower is a solar panel support system for installing solar photovoltaic arrays DESIGN RESPONSIBILITY - o -Ce a o on sloped roofs of buildings. Typically such buildings are residential with shingle or tile roofs. _ _ The Invisimount Design Tool is intended to be used under the responsible charge of a registered 0 in Each row or column of modules is supported by two rails, which are attached to the roof design professional' where required by the authority having jurisdiction. In all cases, the tool z structure. The number and spacing of attachments to the roof structure can vary depending on, should be used under the direction of a design professional with sufficient structural engineering for example, structural loads at a particular site, the type of attachment hardware used, and knowledge and experience to be able to: `f l spacing of the building rafters. • Evaluate whether the tool is applicable to the project, based on the "Engineering Basis of = The attached "Engineering Basis of Calculations" describes the scope of the Invisimount Design Calculations" document and the characteristics of the project, and Tool, its calculation procedures, and assumptions for use. • Understand and determine the appropriate values for all input parameters of the tool. o SCOPE OF OUR REVIEW Results of the tool should be checked against the design professional's judgment. Excerpts from N standards such as ASCE 7-10 are presented in the tool as pointers to the standard and are not o Maffei Structural Engineering collaborated with SunPower on' the development of the intended to diminish the user's responsibility to consult the applicable figures and sections of the Invisimount Design Tool, including the following tasks related to structural calculations: standard directly. The user or design professional in responsible charge assumes full design • Provided documents describing applicable building code formulas and the calculation responsibility. Ce procedure to be implemented by SunPower's programming team The tool does not check the capacity of the building structure to support the loads imposed on the o • Worked with SunPower and the programming team during implementation to answer building by the array, such as bending strength of roof rafters spanning between supports. This questions related to structural calculations and test the functionality of the tool °` OPPORTUNITY SPRI- Fremont = 415.329.6100 B The terms registered design professional and registered design professional in responsible charge are defined in www.maffei-structure.com the 2012 IBC Section 202. PROJECT D-0053465 148 Hermosa Avenue Oakland, CA 94618 DATE DRAWN 05-31-2016 DRAWN BY HLLUVIOSO DATE CHECKED 05-31-2016 J CHECKED BY APATEL FIGURE D: STRUCTURAL SUMMARY - PAGE 1 FIGURE E: STRUCTURAL SUMMARY - PAGE 2 SHEET SOLAR -$4 r pC 'n a$ f � a to �6 W W o 0 a, a i 0 tn Z 3 a U u o � is M o upi toa8 Qm Z 0 4Eq o = v J Bg 11 August 2014 _ SunPower Invisimount Design Tool - MA F F E I Structural Calculations - -_ ERTINO STRUCTURAL ENGINEERING Page 3 ] n • ° • ' • • g Department requires additional knowledge of the building and is outside the scope of the design tool and our "; i(`� t t f i 2016 review. If you have any questions regarding these findings, please call me at 510-604-2688. InvisiMount Component Images c 4 c D FO CODE COMPLIANCE Sincerely, Module* / Mid Clamp and Rall Module* / End Clamp and Rail Reviewed By: Maffei Structural Engineering ILI 94 Joe Maffei, S.E., Ph. D, LEED APON Principal joe@maffei-structure.com �p`, LLI Z Mid Clamp End Clamp Rail & Rail Splice Ground Lug Assembly End Cap UQ U Milli 1111 I n y ~ OIn ^ 0 LU G = Z Ce O I. tv to LL W a to Ili Q_ a Ya' ¢ w O U Q O LUL, LU � 0 Z a to InVisjMoUnt Component,Details• Operating Conditions0 Z Temperature Component — Material Weight -40° C to 901 c(-40° F to 194' Fr - 0 d O 2: Max. Load Mid Clamp Black oxide stainless steel AISI 304 63 g (2.2 oz) 2400 Pa uplift 5400 Pa downforce Y U 01 End Clamp Black anodized aluminum alloy 6063-T6 110 g (3.88 oz) %0 Z Rail Black anodized aluminum alloy 6005-T6 830 g/m (9 oz/ft) Invisimount Warranties And Certifications u1 Rail Splice Aluminum alloy 6005-T5 830 g/m (9 oz/ft) Warranties 25 -year product warranty Ground Lug 304 stainless 106.5 g/m (3.75 oz) 5 -year finish warranty Assembly (A2-70 bolt; tin-plated copper lug) m End Cap Black acetal (POM) copolymer 10.4 g (0.37 oz) UL 2703 Listed Certifications Class A fire rating when distance between o Roof Attachment Har•ware Supported by roof surface and bottom of SunPower Invisimount System Qesign Toolmodule frame is15 3.5" w z 0 Composition Shingle Rafter Attachment Application Composition Shingle Roof Decking Attachment ' • • - • .. Curved and Flat Tile Roof Attachment > Universal Interface for Other Roof Attachments Refer to roof attachment hardware manufacturer's documentation 0 N O J cC OPPORTUNITY SPRI- Fremont 'Module frame that is compatible with the InviSIMOUnl system required for hardware Interoperability. PROJECT D-0053465 ® 2015 SunPower corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respective owners. sunpower.com DATE DRAWN OS -31-2016 Specifications included in this datasheet are subject to change without notice. Document #509506 Rev B DRAWN BY HLLUVIOSO SUNPOWER '• DATE CHECKED 05-31-2016 CHECKED BY APA7EL - FIGURE F: STRUCTURAL SUMMARY - PAGE 3 FIGURE G: INVISIMOUNT DATA SHEET SHEET SOLAR -S5 r Investigated for Bonding ' System Fire Classification (A, B or C) to = InvislMount- consisting Y Y A UL Listed PV Modules: of the following N W W 0 V C m Ln M co Standard(s) for Safety: UL Subject 2703, The Outline of Investigation for Mounting represents numbers 18, 19, 20 or 21, and ### Rail, Rail Splice, Mid to < a Clamp, Ground Lug Ln inZ in to 233; SPR-EYY-###, where YY represents 2/17/2015 QIMS.E466981- Mountingstems, MountingDevices, Clam i Devices and Ground for tth a Panels Clamping r ® o 3 cc numbers 18, 19, 20 or 21, and ### represents v W I $ W CL U) Q a F - any number from 345 to 285 and 250 to 225. All F a m - Z o Ln In Z U� ONLINE CERTIFICATIONS DIRECTORY Z under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up B CERTIFICATE OF COMPLIANCE M a v � J g QIMS.E466981 0 U Additional Information: See the UL Online Certifications Directory at Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for- U° Certificate Number 20150223-E466981 Use with Photovoltaic Modules and Panels Report Reference E466981-20140903 www.ul.com/database for additional information Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non- c Issue Date 2015 -FEBRUARY -23 Page Bottom misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory i'MLPERTINO Mounting Systems, Mounting Devices, Clamping Devices and Iouri L�s�or Departm nt with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in Issued to: SUNPOWER CORP Use with Photovoltaic Modules and Panels ro Only those products bearing the UL Listing Mark should be considered as being covered by UL's 77 RIO ROBLES'" J U N 0 2 2016 • SAN JOSE CA 95134-1859 See General Information for Mounting Systems, Mountinq Devices, Clampinq Devices and Ground Lugs for Use vv}ttrP�pp�tiolta}6 Mbdulasarul PLIANCE N L_6-rL Ti cCTJDE CO Panels The UL Listing Mark generally includes the following elements: the symbol UL in a circle: yL with the This is to certify that MOUNTING SYSTEMS, MOUNTING DEVICES, CLAMPING SUNPOWER CORP E466981 Reviewed By: representative samples of DEVICES AND GROUND LUGS FOR USE WITH 77 RIO ROBLES - SAN JOSE, CA 95134 USA PHOTOVOLTAIC MODULES AND PANELS USL - InvisiM_ ount Mounting and Bonding Systems for use with Photovoltaic Modules, consisting of the following components: L - Foot, Rail, Rail Splice, Mid Clamp, Ground Lug Assembly. These system components have also been evaluated for a Class A System Fire Classification for a steep -sloped roof with Type 2 modules.. (See addendum page for additional information.) Cat. No. Investigated for Bonding Investigated for Mechanical Loading System Fire Classification (A, B or C) Tested In Combination With Photovoltaic mounting system InvislMount- consisting Y Y A UL Listed PV Modules: of the following N Questions? Print this Dage Terms of Use Page To[) - - Sunpower Corp: Models SPR-XYY-###, where YY components: L -Foot, - - D Standard(s) for Safety: UL Subject 2703, The Outline of Investigation for Mounting represents numbers 18, 19, 20 or 21, and ### Rail, Rail Splice, Mid represents any number from 365 to 310 and 274 Clamp, Ground Lug When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment inZ in to 233; SPR-EYY-###, where YY represents Assembly r_% Z Q p = Ne o- numbers 18, 19, 20 or 21, and ### represents Z ce OLL `� Q N M N se W CL U) Q a F - any number from 345 to 285 and 250 to 225. All models identified must have the Gen 5 frame and have a Type 2 module characterization. Have been investigated by UL in accordance with the Last Updated on 2014-09 26 WLu in Z N U.1 t~n I- P— z O N Questions? Print this Dage Terms of Use Page To[) - - _ — - LLI - - D Standard(s) for Safety: UL Subject 2703, The Outline of Investigation for Mounting -- - - - ©zols UL LLC Y Systems, Mounting Devices, Clamping/Retention Devices, and When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment inZ in LL r_% Z Q p = Ne o- C� a Z ce OLL `� Q N M N se W CL U) Q a F - Have been investigated by UL in accordance with the Last Updated on 2014-09 26 WLu in Z N Standard(s) indicated'on this Certificate.o I- P— z Questions? Print this Dage Terms of Use Page To[) - - _ — - LLI - - D Standard(s) for Safety: UL Subject 2703, The Outline of Investigation for Mounting -- - - - ©zols UL LLC Y Systems, Mounting Devices, Clamping/Retention Devices, and When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment inZ database for additional information regarding this product's certification. ui 21 Ground Lugs for use with Flat -Plate Photovoltaic Modules and The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured Panels under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up B Service. Always look for the Mark on the product. Additional Information: See the UL Online Certifications Directory at - UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide www.ul.com/database for additional information Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non- c misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in V) Only those products bearing the UL Listing Mark should be considered as being covered by UL's the following format: "© 2015 UL LLC". o Listing and Follow -Up Service. N The UL Listing Mark generally includes the following elements: the symbol UL in a circle: yL with the > word "LISTED"; a control number (may be alphanumeric) assigned by UL; and the product category o name (product identifier) as indicated in the appropriate UL Directory. • V7 L Look for the UL Listing Mark on the product. O i OPPORTUNITY SPRI- Fremont Wllllam R. Camey, Director, North Amoricen CertHlcation Programs �L PROJECT D-0053465 _ UL LLC Any Infonnatlon and doamentatlon Involving UL Mark services are provided on behalf of UL LLC (UL) or any author" licensee of UL For questbns, please contactaloWLLCustomerSomiceRepmwnta6veatwww.ul.comleonbclua - - _ _ - - - - - - - - - - DATE DRAWN 05-31-2016 DRAWN BY HLLUVIOSO 3' Page 1 of 2 DATE CHECKED 05-31-2016 hUpJ/database.ul.com/cgi-binXYV/tempWefUSEXT/1 FRAM E/shawpage.html7name=QIMS.E466981&ccnshorttitle=Mounting+Systems,+Mounting+Devices +... 1/1 CHECKED BY APATEL -- FIGURE H: CERTIFICATE OF COMPLIANCE FIGURE I: CLASS A FIRE RATING UL LISTING FHI- SOLAR -S6 I. I. -"' .. .. Al SUNPOWER MODULES SPR -E20-327 A ROOFTOP ARRAY WIRING MPPT 1: STRING 1 5 MODULES/STRING MPPT 1: STRING 2 5 MODULES/STRING MPPT 2: STRING 1 7 MODULES/STRING , JUNCTION BOX, NEMA -3R, J A HOFFMAN Al2R106 OR EQUIVALENT TAG DESCRIPTION Q SOLAR PV MODULE / STRING Q DC / DC CONVERTERS A SOURCE CIRCUIT JUNCTION BOX ® SEPARATE DC DISCONNECT © INTERNAL INVERTER DC DISCONNECT STRING INVERTER e SOLAR LOAD CENTER Q PV PRODUCTION METER Q9 SEPARATE AC DISCONNECT CHECK BOX FOR WHETHER SYSTEM IS GROUNDED OR UNGROUNDED: ❑ GROUNDED (INCLUDE GEC) 62r UNGROUNDED FOR UNGROUNDED SYSTEMS: • DC OCPD DISCONNECT BOTH CONDUCTORS OF EACH SOURCE CIRCUIT. • UNGROUNDED CONDUCTORS MUST BE IDENTIFIED PER _ 210.5(C). WHITE FINISHED CONDUCTORS ARE NOT PERMITTED. i FIGURE A: SINGLE LINE DIAGRAM - NO STRINGS COMBINED PRIOR TO INVERTER: 5.56 kWDC A6SBSOODTL-US-22 (Sunny Boy) - 240 VAC INVERTER EFFICIENCY 97.00% RATED MAX OUTPUT CURRENT = 22.00A \AC INTERNAL A DC DISCONNECT DATA COMM. CABLE ❑ TO SUNPOWER SPS OUTLET MONITORING /SWITCH SYSTEM 30 A A UTILITY -LOCKABLE SAFETY SWITCH 30A, 240VAC CUTLER -HAMMER DG321NRB OR EQUIVALENT LOCATED OUTSIDE NEXT OF MAIN SERVICE PANEL WITH VISIBLE KNIFE BLADES REFER AC DISCONNECT SPECIFICATION - SOLAR -E9 SHEET CONDUCTOR/ CONDUIT SCHEDULE TAG DESCRIPTION & CONDUCTOR TYPE NO YES❑ A PV -WIRE NO EGC: BARE COPPER YESTHWN-2 B #10 AWG 1 YES EGC: THWN-2 NO C THWN-2 NO EGC: THWN-2 YES❑ D THWN-2 EMT EGC: THWN-2 E THWN-2 EGC: THWN-2 30 A A UTILITY -LOCKABLE SAFETY SWITCH 30A, 240VAC CUTLER -HAMMER DG321NRB OR EQUIVALENT LOCATED OUTSIDE NEXT OF MAIN SERVICE PANEL WITH VISIBLE KNIFE BLADES REFER AC DISCONNECT SPECIFICATION - SOLAR -E9 SHEET CONDUCTOR/ CONDUIT SCHEDULE CONDUCTOR SIZE NUMBER OF CONDUCTORS CONDUIT/CAI #10 AWG 6 Ln bQ #10 AWG 1 #10 AWG 6 EMT #10 AWG 1 #SO AWG 3 EMT #10 AWG 1 #14 AWG 4 EMT #14 AWG 1 #6 AWG 3 EMT #10 AWG 1 — -- -- — — — — — LINE SIDE TAP ILSCO KUP-L-TAP IPC -4/0-6 REFER SPECIFICATION TO SOLAR -E11 SHEET PV AC DISCONNECT LOCATED NEXT TO MSP WITHIN SO' FROM THIS TAP �. 4 TO EXISTING LOADS INCOMING SOURCE FEED TOP -FED (N) MAIN SERVICE PANEL 125A MIN., 120/24OV, SPH, 3W LOCATION: SW CORNER OF HOU'- ELECTRICAL NOTES CONDUIT SIZE q O 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. Ln bQ -- 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES U1 Z SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND FJb 3/4" RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF O o ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT 01 SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH 3/4" MEYERS HUBS TO BE USED. - a 3. INSULATED BONDING BUSHINGS TO BE USED ON ALL CONDUIT TERMINATIONS REGARDLESS OF VOLTAGE. THE 1/2" INSULATING FITTINGS SHALL BE SUITABLE FOR BONDING TO GROUND IN ACCORDANCE WITH NEC 250.92. INSULATED BOX CONNECTORS DO NOT MEET THIS REQUIREMENT. 3/4" 4. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL V) LUGS, FITTINGS, CRIMPS, ETC. S. ALL CONDUIT BEND RADII TO CONFORM TO THE NEC MINIMUM BEND RADII REQUIREMENTS. ® 6. MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR U U , ALL NEW EQUIPMENTS TO BE INSTALLED. 7. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC A AND LOCAL UTILITY REQUIREMENTS. O C 8. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. w tn 9. ELECTRICAL METALLIC CONDUIT (EMT) SHALL BE USED FOR 1.i ALL EXTERNAL CONDUIT INSTALLATION. �. 4 TO EXISTING LOADS INCOMING SOURCE FEED TOP -FED (N) MAIN SERVICE PANEL 125A MIN., 120/24OV, SPH, 3W LOCATION: SW CORNER OF HOU'- MCB J ERTINO 100A, 2P 4; Tr L° t I I n ( ,s�NAL ETSF ui �j epai tment M EfiNOit�? 12016 66aa15D�._.<,z , E F R CODE COMPLIANCE I �I a ewe y: 9� EXI NG 1 GROUND _ NOTE: BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. • SUNPOWER MONITORING SYSTEM • SECURE POWER SUPPLY (SPS) • GFCI OUTLET JUNCTION BOX (JB) MAY ONLY NEED TO BE INSTALLED WHEN REQUI_RED,AND-NEEDSZO_BE—_ IDENTIFIED IN THE FIELD. INSTALLATION NOTE: • PLC CONNECTION FOR MONITORING, FROM BOS TO OFFICE FRONT CORNER - OPPOSITE SIDE OF HOUSE. • UPDATE EXISTING GROUNDING PRIOR INSTALL. FIGURE B: MONITORING SYSTEM MAIN SERVICE PANEL 1P I ISA, 1P PV SUPERVISOR 1/2" EMT CAT5e­- 2) #14 THWN-2 (1) #14 THWN-2 EGC ETHERNET GFCI CONNECTION TO 1/2" EMT DSL/CABLE MODEM (2) #14 THWN-2 (1) #14 THWN-2 EGC (� FROM INVERTER DATA COMMUNICATION CABLE LU U) U Q Z O Q O Z Q a LLI uJ cz- L.7 V7 L9 Ln SPRI- Fremont F- q O Q) Ln bQ Q rti O N =) v U1 Z w FJb LU w O o Lu Z .-, 01 Lna Q V) U 06 -a- - a ULU LU V) Qco 3 ® Z U U , O A O O C a Ln w tn G F 1.i r 03 z z P Z aoow c<1 O aU v J y .. Q !!/^� O K U X4 y, Ua MCB J ERTINO 100A, 2P 4; Tr L° t I I n ( ,s�NAL ETSF ui �j epai tment M EfiNOit�? 12016 66aa15D�._.<,z , E F R CODE COMPLIANCE I �I a ewe y: 9� EXI NG 1 GROUND _ NOTE: BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. • SUNPOWER MONITORING SYSTEM • SECURE POWER SUPPLY (SPS) • GFCI OUTLET JUNCTION BOX (JB) MAY ONLY NEED TO BE INSTALLED WHEN REQUI_RED,AND-NEEDSZO_BE—_ IDENTIFIED IN THE FIELD. INSTALLATION NOTE: • PLC CONNECTION FOR MONITORING, FROM BOS TO OFFICE FRONT CORNER - OPPOSITE SIDE OF HOUSE. • UPDATE EXISTING GROUNDING PRIOR INSTALL. FIGURE B: MONITORING SYSTEM MAIN SERVICE PANEL 1P I ISA, 1P PV SUPERVISOR 1/2" EMT CAT5e­- 2) #14 THWN-2 (1) #14 THWN-2 EGC ETHERNET GFCI CONNECTION TO 1/2" EMT DSL/CABLE MODEM (2) #14 THWN-2 (1) #14 THWN-2 EGC (� FROM INVERTER DATA COMMUNICATION CABLE LU U) U Q Z O Q O Z Q a LLI uJ cz- L.7 V7 L9 Ln OPPORTUNITY SPRI- Fremont v q O Q) Ln bQ Q rti O N UJ �r U1 Z = U M J P �LU Q Y o NL7 i U O Lu Z .-, O 01 Z Lna Q V) U 06 -a- - a ULU LU OPPORTUNITY SPRI- Fremont PROJECT D-0053465 DATE DRAWN 05-31-2016 DRAWN BY HLLUVIO50 DATE CHECKED 05-31-2016 CHECKED BY APATEL SCALE NOT TO SCALE SOLAR—E1 DC, MPPT 1 MAXIMUM SYSTEM VOLTAGE (DC) 346.58 V LOWEST AMBIENT TEMPERATURE FOR SITE 0°C PV MODULE OPEN CIRCUIT VOLTAGE 64.9 V PV MODULE VOC TEMPERATURE CORRECTION COEFFICIENT -176.6 mVrC PV MODULES PER STRING 5 VMAX = (VOC + (VOC-COEFF / 1000) x (TMIN-25)) x MODULES -STRING 346.58 V MAXIMUM SYSTEM CURRENT (DC) 8.08 A PV MODULE SHORT CIRCUIT CURRENT 6.46 A MULTIPLIER, HIGH IRRADIANCE (1250W/m2) FOR> 3h 1.25 [MAX DC = ISC x 1.25 8.08 A ROOFTOP ARRAY WIRING (DC) #10 MINIMUM WIRE AMPACITY: [WIRE -MIN = IMAX DC x 1.25 10.09 A CONDUCTOR DE -RATING } :k MAXIMUM AMBIENT TEMPERATURE 54°C TEMPERATURE DE -RATING COEFFICIENT 0.76 CURRENT CARRYING CONDUCTORS/CONDUIT 1-3 CONDUIT FILL DE -RATING COEFFICIENT 1 CONDUCTOR AMPACITY - CONDITION OF USE = 30.4 A (>8.08 A) WIRE AMPACITY SELECTED X TEMP COEFF. X FILL COEFF. 30 A CONDUCTOR AMPACITY - TERMINAL TEMP LIMIT 35 A (>10.09 A) ROOF PENETRATION TO INVERTER WIRING (DC) #10 MINIMUM WIRE AMPACITY: IWIRE MIN = IMAX DC x 1.25 10.09 A CONDUCTOR DE -RATING 0 w K MAXIMUM AMBIENT TEMPERATURE 61 °C TEMPERATURE DE -RATING COEFFICIENT 0.58 CURRENT CARRYING CONDUCTORS/CONDUIT 4-6 CONDUIT FILL DE -RATING COEFFICIENT 0.8 CONDUCTOR AMPACITY - CONDITION OF USE = 18.56 A (>8.08 A) WIRE AMPACITY SELECTED X TEMP COEFF. X FILL COEFF. CONDUCTOR AMPACITY - TERMINAL TEMP LIMIT 35 A (>l0.09 A) CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 VOLTAGE DROP AT 100 FT CONDUCTOR DISTANCE 0.54 ELECTRICAL CALCULATIONS DC, MPPT 2 MAXIMUM SYSTEM VOLTAGE (DC) 485.21 V LOWEST AMBIENT TEMPERATURE FOR SITE 0°C PV MODULE OPEN CIRCUIT VOLTAGE 64.9 V PV MODULE VOC TEMPERATURE CORRECTION COEFFICIENT -176.6 mVPC PV MODULES PER STRING 7 VMAX = (VOC + (VOC_COEFF / 1000) x (TMIN-25)) x MODULES -STRING 485.21 V MAXIMUM SYSTEM CURRENT (DC) 8.08 A PV MODULE SHORT CIRCUIT CURRENT 6.46 A MULTIPLIER, HIGH IRRADIANCE (1250W/m2) FOR> 3h 1.25 IMAX -DC = ISC x 1.25 8.08 A ROOFTOP ARRAY WIRING (DC) #10 MINIMUM WIRE AMPACITY: IWIRE MIN = [MAX -DC x 1.25 10.09 A CONDUCTOR DE -RATING } :k MAXIMUM AMBIENT TEMPERATURE 54°C TEMPERATURE DE -RATING COEFFICIENT 0.76 CURRENT CARRYING CONDUCTORS/CONDUIT 1-3 CONDUIT FILL DE -RATING COEFFICIENT 1 CONDUCTOR AMPACITY - CONDITION OF USE = 30.4 A (>8.08 A) WIRE AMPACITY SELECTED X TEMP COEFF. X FILL COEFF. 30 A CONDUCTOR AMPACITY - TERMINAL TEMP LIMIT 35 A (>10.09 A) ROOF PENETRATION TO INVERTER WIRING (DC) #10 MINIMUM WIRE AMPACITY: [WIRE -MIN = IMAX DC x 1.25 10.09 A CONDUCTOR DE -RATING 0 w K MAXIMUM AMBIENT TEMPERATURE 61 °C TEMPERATURE DE -RATING COEFFICIENT 0.58 CURRENT CARRYING CONDUCTORS/CONDUIT 4-6 CONDUIT FILL DE -RATING COEFFICIENT 0.8 CONDUCTOR AMPACITY - CONDITION OF USE = 18.56 A (>8.08 A) WIRE AMPACITY SELECTED X TEMP COEFF. X FILL COEFF. CONDUCTOR AMPACITY - TERMINAL TEMP LIMIT 35 A (>10.09 A) CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 VOLTAGE DROP AT 100 FT CONDUCTOR DISTANCE 0.39 AC INVERTER TO GRID -TIE WIRING (AC) #10 INVERTER RATED POWER 5000 W INVERTER/ GRID VOLTAGE 240 V INVERTER RATED MAX OUTPUT CURRENT: IAC -OUT 22.00 A MINIMUM WIRE AMPACITY: IMAX = IAC -OUT x 1.25 27.50 A CONDUCTOR DE -RATING W MAXIMUM AMBIENT TEMPERATURE 36°C TEMPERATURE DE -RATING COEFFICIENT - CURRENT CARRYING CONDUCTORS/CONDUIT b,y.: �•/s��' En UI Q 2 J CONDUIT FILL DE -RATING COEFFICIENT eirl 1 CONDUCTOR AMPACITY - CONDITION OF USE = 27.3 A (> .06A' WIRE AMPACITY SELECTED X TEMP COEFF. X FILL COEFF. } :k CONDUCTOR AMPACITY - TERMINAL TEMP LIMIT 30A( fiBd CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP _#10 VOLTAGE DROP AT 50 FT CONDUCTOR DISTANCE �tY/ol OVERCURRENT PROTECTION (AC) 30A, 2P MINIMUM OCPD = IAC x 1.25 27.50 A NEXT LARGER OCPD SIZE 30 A }F T 1".� �.! !t.%1O""' N - GC 'j) f _ = a in as tJ b E - W W Y O O , 0 O M V7 M m M F SLE }) En UI Q 2 J O Ln c , u oo # ~ Q 0 Q F -O Q a = Lu w F- O W � O Z � ¢ U O W Z Q N f7 w J U .i u w Z 7 '`r O o M w N 5 5$E6 F _ ?� U 1- Q NI Z K 0 o .a U t0 0 w K U J8 Ln V+ 0 u a u S! RTINO : CUF E I Building I epartment IFlq 0 2016 =WED FOR DE COMPLIANCE Reviewed y: }F T 1".� �.! !t.%1O""' N - z OE u u N O OPPORTUNITY SPRI- Fremont PROJECT D-0053465 DATE DRAWN 05-31-2016 DRAWN BY HLLUVIOSO DATE CHECKED 05-31-2016 CHECKED BY APATEL SCALE NA SHEET SOLAR -E2 W E - Ln En UI Q 2 J bH •--� rn (f) O_ f- ~ Q 0 Q F -O Q a = Lu w F- O W � O Z � ¢ U O W Z Q N f7 w J U .i u w -� - C7CLw -- -- - W- - _ ?� U .Y t0 Ln In z OE u u N O OPPORTUNITY SPRI- Fremont PROJECT D-0053465 DATE DRAWN 05-31-2016 DRAWN BY HLLUVIOSO DATE CHECKED 05-31-2016 CHECKED BY APATEL SCALE NA SHEET SOLAR -E2 OC A = f a n Fj 8 W W o o 3 U 0 Re Z U C W qcN O =o o M U) DO Z W g ¢ Q 11 O K Q U v J PV a ug c + O u U a 6 ,R 1 1N® )epartment C DE COMPLIANCE AC r W V1 Ul Ul a LO z rn O �ZL O LU Z U Q H rary > �_ d' N iVi Q O M LL Z O Y �. U 2 LU a O V a Ln 0 } W W rn Z � z ~ ri J �— - -w— U g U LTI ui U m i 0 vv U1 Z E O d }_ N o j � o W U °da OPPORTUNITY SPRI- Fremont PROJECT D-0053465 DATE DRAWN 05-31-2016 DRAWN BY HLLUVIOSO IN 0 DATE CHECKED 05-31-2016 CHECKED BY APATEL SCALE NOTTO SCALE SHEET SOLAR -E3 • LABELING SPECIFICATIONS O WARNING: WARNING: X11 DUAL POWER SOURCES. SECOND 6.. INVERTER OUTPUT CONNECTION; IIII SOURCE IS PHOTOVOLTAIC SYSTEM. DO NOT RELOCATE THIS RATED AC OUTPUT CURRENT: OVERCURRENT DEVICE 22.00 A AC NORMAL OPERATING VOLTAGE: 240V RATED AC OUTPUT CURRENT: 22.00A A AC NORMAL OPERATING • ® • , � ■ ® • • � . � � _ p �• � r.. VOLTAGE: 240V - �� ��D ® ® ®• e o WARNING: ELECTRIC SHOCK • • • � • _ s°I° 0 0 0 • - •N HAZARD. IFA GROUND FAULT IS • ,_ {• ; ,;• ° 0 e � INDICATED NORMALAG 4 LY GROUNDED Jlfi, .y ® e ® e • �• j, - -, p . 0 , CONDUCTORS MAYBE UNGROUNDED AND ENERGIZED �"� K��' • �•' WARNING: ELECTRIC SHOCK • e e • � HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC INTEGRI}iEl1�� SF?TEM' �• • TOUCH e SIGNAGE LOCATIONS: SYSTEM ARE UNGROUNDED AND � DC DISO�NNE(,7:`;;y.�,.;.;I'�!; TERMINALS. MAY BE ENERGIZED. INVERTER RATED ,pq�YER=pO1N[�,*J� V Sul (� � INVERTER TERMINALS • • i .INVERTER INTEGRATED DC DISCONNECT CI11iREN .r1�kB6 BOTH e RATED �DWEg•�If,11n,� LOAD e , SIDES e • � SHORT C RR, WIT CdRRE"NT,1�.15 A • • POSITION. Maxsrs �E3gB5 Dc I 0 I I I � " • • 11.96 ADC WARNING: I = • ' • ' • • 404 VDC PHOTOVOLTAIC POWER SOURCE - � .•, ��-=.'-,' ,=, '�"r „�� I m 46svoc REVIcVVED PO DISCONNECT I � % I � •' 16.15A Reviewed p ---------- ----.J SIGNAGE LOCATIONS: SERVICE POINTE 17 PANEL INVERTER INTEGRATED DC DISCONNECT UTILITY METERING PHOTOVOLTAIC SYSTEM ��n �59y ��®� UU� REFERENCES: ALL REQUIREMENTS ARE MET BY: **2013 CALIFORNIA ELECTRICAL CODE** SIGNAGE NOTES 1. MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. 2. ALDISCONNECT MARKING LU L SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITH MINIMUM 3/a" LETTER HEIGHT, N • ;d ' m� � WHITE ON RED BACKGROUND. , DISCONNECT E A LOCATION CLEARLY VISIBLE FROM THE LOCATION WHERE THE LEVER - SHALL B PLACED ADJACENT TO MAIN SERVICE � i •. IN e , ® v r -�• � r- r .-. -*-"!y' ''i fr,`.. :•, � .. �� ®. _ � �� IS OPERATED. B k t s �u_,-^• _ - � �; �i � �`} � .F � r t'N� 4. MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, a, •." •• Ull��I�OJIIUUli _ _ _ . -• f- . ✓ " ` . I ', ASSEMBLIES, AND JUNCTION BOXES TO ALERT THE FIRE SERVICE _ I jA.. ENCLOSURES, CABLE ASSE - TO -AVOID -CUTTING THEM:MARKINGSSHALL REPLACED EVERY 10, AT TURNS AND © `® ° - — — r s F >': � �' I"1" : �" � �- - = � '�°f'��aii;��iG�4.-• ABOVE AND/OR BELOW PENETRATIONS, AND AT AL -41 L DC COMBINER AND JUNCTION BOXES. ._ 4 • F"-�-n�� � � g •"�� SIGNAGE LOCATIONS: 240 VAC 5. DO NOT USE SCREWS FOR SIGNAGE ATTACHMENT. USE ONLY APPROVED ADHESIVE. • MAIN SERVICE PANEL SIGNAGE LOCATIONS: SIGNAGE LOCATIONS: • MAIN SERVICE PANEL .MAIN SERVICE PANEL 0 I 61•.. z. a• a •e• ® e �•®a :e �• P .... ' �# ai �`.. � >�•.: ©,. o ,�a����+r�aa-:�� - ( 22.00 A ©'. � __ f .l 240 VAC y • o •- o �� 240 VAC SIGNAGE LOCATIONS: SIGNAGE LOCATIONS: SIGNAGE LOCATIONS: • ADJACENT TO PV BREAKER • OUTDOOR AC DISCONNECT • DC CONDUIT - • REFER TO NOTE # 4 I SUNPOWER OFFERS THE BEST COMBINED POWER AND PRODUCT WARRANTY POWER WARRANTY PRODUCT WARRANTY I 45 a 90% i 85% Soo http://v .wnpoHer.com/foes For mono refewco infom+alion. for more details, sea axfended dotoshem w .sunperwer.com/dctoshWsiRcad safety and InsiolinKon tnstruuions before using this product. www.sunpOWer.com ®December 201 d SunPower Corporation: NI rights reserved. SUNPOWER, The SUNPOWER logo, MAXEON, MORE ENERGY. FOR UFE., and SIGNATURE aro trademarks or r4alcred Doc"mem r SaaBM iv, D ATF -US xodcmcrks of SwrPawor Corporation. Specifications, irtckrdod in Lrlis dclashcrot am wbject 10 change witFqul rrolico. FIGURE A: PV MODULE SPECIFICATION SHEET Sun. Bay 30007E -US LLI W N 0 5 10 IS 20 25 0 5 10 15 20 25 Yeon NEMA3R. Years More guaranteed power: 95% for first 5 years, Combined Power and Product defect 25 year coverage -0.414/yr. to year 25.8 that includes panel replacement costs. ° ELECTRICAL DATA - QPERATING CONDITION ANY MECHANICAL DATA - -- -- 3200 W E20-327 E19-320 Temperature - 40°F to + 185'F (- 40°C to +85°C) 600 V _ Nominal Power (Pham) 327 W 320 W Max load Wind; 50 psi, 2400 Pa, 245 k9/m2 Front &back 175 - 480 V_ Power Tolerance +5/-0% +5/-0% _ _ Snow: 112 psf, 5400 Pa, 550 kg/m2 front 125 - 500_Y Avg. Panel Efficiency's 20.40/. 19.8% Impact resistance 1 inch (25mm) diameter hail at 52 mph (23 m/s). , 1 125 y'/150Y - = Rated Voltage (Vmpp) 54,7 V 54.7 V- Appearance Class A = o Rdfed Current (Impp) 5.98 A 5.86 A Solar Cells 96 Monocrystalline Moxeon Gen II rr ti�:nrh O en•Circuit Voltage Voc 64.9 V 64.8 V P 9 ( ] Tempered Glass - - High transmission tempered Anti -Reflective_, - Short -Circuit Current (Isc) 6.46 A 6.24 A Junction Box - IP -65 Rated _ 3000 Vi Max. System Voltage 600 V UL & 1000 V IEC Connectors MC4 Compatible Connectors O 'a IMaximum Series Fuse 15 A - I Frame Class 1 black anodized (highest AAMA rating) - 208'V./ • 240 V / - - --------° Weight 41 lbs (18.6 kg) 1'89 - 229 V 211 - 264 V . _ Power Temp Coef. -0.38 /a / °C - -- --- - ----- ------ 60 Hz / 59 3 --60.5 Hz Voltage Temp Coef. -176.6 mV / °C 60 Hz/ 59:3 - 60.5 Hz TESTS AND CERTIFICATIONS - 15 A_ Current Temp Coef. 3.5. mA / °C _. Standard tests ' __ "'-- - '- - - - - - - - - --- - UL1703 (Type 2 Fire Rating), IEC 61215, IEC 6.1730 REFERENCES: Quality tests _ ISO 9001:2008, ISO 14001:2004 _- -__ 1 1 All comparisons are SPR -E20-327 vs. a representative conventional. panel: 250W, EHS Compliance ROHS, OHSAS 18001:2007, lead free approx, 1.6 ma, 15.3% efficiency. Aminonio-lest IEC�27 2 PVEvo ution tabs "SunPower Shading Study,' Feb 2013. I Salt Spray test IEC 61701 (passed maximum severity) 3 Typically 7-9% more energy per watt, BEW/DNV,Engineering "SunPower Yield PID test - Potential -Induced Degradolion free: 1 OOOV10 Report," Jan 2013. _ 4 SunPower 0.25%/yr degradation vs. 1.0%/yr conv. panel. Campeau, Z. at cl. I Available listings UL, :CEC, CSA, TUV, JET, KEMCO, MCS, FSEC "SunPower Module Degradation Rate," SunPower white paper, Feb 2013; Jordan, Dirk "SunPower Test Report," NREL, Oct 2012. 5 "SunPower Module 40 -Year Useful Life" SunPower white paper, Feb 2013. Useful T life is 99 out_of 100 panels operating at more than 70% of rated power. 6 Second highest, cher SunPower XSeries, of over 3,,200 silicon solar panels, Photon Module Survey, Feb 2014. 1046 nlln 7 8% more energy than the average of the top 10 ponel,componies tested in 2012 [41.2 In] (151 panels, 102 companies),.Photon International, Feb 2013. E 8 Compared with the fop 15 manufacturers. SunPower Warranty Review, Feb 2013. 9 Some exclusions 'apply. See warranty for details. 10 5 of top 8 panel manufacturers from 2013 report were tested, 3 additional 46 mill 1559 mm �I silicon solar panels for the 2014. Ferrara, C., el al. "Fraunhofer PV Durability [1.8 ill] 161.4in] Initiative for Solar Modules: Part 2". Photovoltaics International, 77-85. 2014. 11 Compared with the non-stress-lested control panel- Atlas 25+ Durability test report; Feb 2013.from 2013 report were tested, 3 additional silicon solar panels for the 2014. Ferrara, C., at al. "Fraunhofer PV Durability Initiative for Solar _ Modules: Part 2". Pholovoltaics International, 77-85. 2014. = 12 Standard Test Conditions (1000 W/m2 irradiance, AM 1.5, 25° C). - 13 Based on average of measured power values during production Soo http://v .wnpoHer.com/foes For mono refewco infom+alion. for more details, sea axfended dotoshem w .sunperwer.com/dctoshWsiRcad safety and InsiolinKon tnstruuions before using this product. www.sunpOWer.com ®December 201 d SunPower Corporation: NI rights reserved. SUNPOWER, The SUNPOWER logo, MAXEON, MORE ENERGY. FOR UFE., and SIGNATURE aro trademarks or r4alcred Doc"mem r SaaBM iv, D ATF -US xodcmcrks of SwrPawor Corporation. Specifications, irtckrdod in Lrlis dclashcrot am wbject 10 change witFqul rrolico. FIGURE A: PV MODULE SPECIFICATION SHEET REVI -VIYED FOR CODE COMPLIAN, Reviewed By: we�- R E tl7' I Sun. Bay 30007E -US LLI W N � a O O 'ny N atin £ aF e NEMA3R. 208 V AC 240 VAC 208 V AC 240' V AC 208 V. AC 24_ _0 VAC Input (DC) Max. usable DC ower ,cos _P I . _� _ �) _ - -- -- 3200 W ._.- 4200 W 4200:W _ . in 600 V _ 600 V 600 V - ¢$ 175 - 480 V_ 175 - 480 V _ _ _ _1 175 - 480 V•_ MPPT operating.Yoltage range 125 - 500_Y 125 - 500V 125 - _500 V :- Min ,DCvolmge/ntartyoltgge._ 125 y'/150Y - = C�IPERT'p`I 125V%150V_ - Max, 6perafing,input cuuent/-per MPP tracker = o 24A% 18 A. 24 A / 16A - F rr ti�:nrh 2/2 . Output (AC) W AC nominal PoN BS _ 3000 Vi ,&.Biding Department Z Max. At apparent power O 'a O = Namindl AC vdtage./adiuslpble _ 208'V./ • 240 V / 208 V./ 0 _ 240V / _ 206,Y / • _ 240 V % ! _ AC alb era e _ Y . 9 ng 1'89 - 229 V 211 - 264 V . _ 1 B3 - 229 211 - 264 V V 163_ - 229 V 211 264 V AC grid frequency; range 60 Hz / 59 3 --60.5 Hz 60 Hz /-59.3 - 66.5 Hz - 60 Hz/ 59:3 - 60.5 Hz o. af - 15 A_ - _ 16A - ¢ Power factor (cos rp) 2 2016 U _ U HarmoniasI _ _ 54% _ <4% <4% REVI -VIYED FOR CODE COMPLIAN, Reviewed By: we�- R E tl7' I Efficiency Max efficiency 97.2% 976% 97.2% 97.5% 97.2% --EC efficwncy - 96:5 965%- _ 96.5% _ _ _ 970° _ _-_ 96,5%. -Protection devices Ground FauU monitonng /Grid monlonng . AC,shod mrcul protection All.pote sensitive residual current monitoring unit Arafaul-t circuit interrupter (AFCI) complidnt to UL 1699B Protection class./ overvoUage_calegory General data Dimensions (W / H / D) m mm (in) DC Disconnect drmenaons IW / H / D) in mm ITnI Packing dimensions (W / H / D] m mm (in) DC.,Disconnect pacWng dimenglons 11V % H % D) m mm (in) Weight / DC'Vis conneet weight Peeking welghj%.DC Disconnect packing weight _ Operptirig temp-irciture range - Noise emission (typical)' , _ _ Internal consumption at night - Topology Cooling Electronics pr&ection Toting, Features 5ecure Power Supply Display. graphic Interfaces: RS485 / Speedwire/Webconnect Wamoaly: 10 /15 / 20 years Certificatas and permits (more available on request) NOTE US inverters ship with;gray lids Type ilesgnal i I 490/519/165 (19.3/20.5/73). 187/297/190 (74/117/-7.5) ,. 617/597/266 (243/235/10.5) 370 /240 /-260. (14.6 / 9.4 / 11.0) 24 kg (5316) / 3.5 kg (Sib) _ 27 kg (6016) /3,S Irq (B Ib(_ -40 °C:..+60 °C (-40 °F...+140 "F), 5 25 dB(A) Sun. Bay 30007E -US Sunny Boy'3800TL-US Sunrry Boy4D00TL-US Technical data 'ny Conyecfion_ Convection NEMA3R. 208 V AC 240 VAC 208 V AC 240' V AC 208 V. AC 24_ _0 VAC Input (DC) Max. usable DC ower ,cos _P I . _� _ �) _ - -- -- 3200 W ._.- 4200 W 4200:W _ . Max. DC wltage._ 600 V _ 600 V 600 V - Rafed MPPI voltagerange - - _ - _- - 175 - 480 V_ 175 - 480 V _ _ _ _1 175 - 480 V•_ MPPT operating.Yoltage range 125 - 500_Y 125 - 500V 125 - _500 V :- Min ,DCvolmge/ntartyoltgge._ 125 y'/150Y - = 125V/150V 125V%150V_ - Max, 6perafing,input cuuent/-per MPP tracker _.. 18A/ 15:A 24A% 18 A. 24 A / 16A - Number of.MWkackers,/ strings per MPf hacker 2/2 . Output (AC) AC nominal PoN BS _ 3000 Vi 333(ZV 3840. W _ 4000 V/ Max. At apparent power 3000 VA: 3330 VA 3840 VA .,_ 4000 VA._ _ Namindl AC vdtage./adiuslpble _ 208'V./ • 240 V / 208 V./ 0 _ 240V / _ 206,Y / • _ 240 V % ! _ AC alb era e _ Y . 9 ng 1'89 - 229 V 211 - 264 V . _ 1 B3 - 229 211 - 264 V V 163_ - 229 V 211 264 V AC grid frequency; range 60 Hz / 59 3 --60.5 Hz 60 Hz /-59.3 - 66.5 Hz - 60 Hz/ 59:3 - 60.5 Hz . Max. outputcunant_ - 15 A_ - _ 16A - 20 A _ Power factor (cos rp) Outputphases /line connections _ HarmoniasI _ _ 54% _ <4% <4% Efficiency Max efficiency 97.2% 976% 97.2% 97.5% 97.2% --EC efficwncy - 96:5 965%- _ 96.5% _ _ _ 970° _ _-_ 96,5%. -Protection devices Ground FauU monitonng /Grid monlonng . AC,shod mrcul protection All.pote sensitive residual current monitoring unit Arafaul-t circuit interrupter (AFCI) complidnt to UL 1699B Protection class./ overvoUage_calegory General data Dimensions (W / H / D) m mm (in) DC Disconnect drmenaons IW / H / D) in mm ITnI Packing dimensions (W / H / D] m mm (in) DC.,Disconnect pacWng dimenglons 11V % H % D) m mm (in) Weight / DC'Vis conneet weight Peeking welghj%.DC Disconnect packing weight _ Operptirig temp-irciture range - Noise emission (typical)' , _ _ Internal consumption at night - Topology Cooling Electronics pr&ection Toting, Features 5ecure Power Supply Display. graphic Interfaces: RS485 / Speedwire/Webconnect Wamoaly: 10 /15 / 20 years Certificatas and permits (more available on request) NOTE US inverters ship with;gray lids Type ilesgnal i I 490/519/165 (19.3/20.5/73). 187/297/190 (74/117/-7.5) ,. 617/597/266 (243/235/10.5) 370 /240 /-260. (14.6 / 9.4 / 11.0) 24 kg (5316) / 3.5 kg (Sib) _ 27 kg (6016) /3,S Irq (B Ib(_ -40 °C:..+60 °C (-40 °F...+140 "F), 5 25 dB(A) < 25 dB(A) <'lW <1W Transformedess, Transformedeps _ Conyecfion_ Convection NEMA3R. NEM, 3R <w Trandognedess Convection NEMA 3R 6/0 0/0 q/o •/o/o .0/o/o •/o/o UL 1741, UL 1998, UL 169.98, IEEE1547 FCC Part 15_(C1cssA & B),_CM/CSA C22 2 10.7.1-1 SB 3006TWS-22; _ S8 3 BOOTL--US-22 -SB 4000TL US -22 FIGURE B: INVERTER SPECIFICATION SHEET N X W Ln } Ln U Q Z O rQ-r O Q ~ Q a 2 WW Y L9 Ln OPPORTUNITY PROJECT DATE DRAWN DRAWN BY DATE CHECKED CHECKED BY 0 In a) U Q = O. ILL Y -i U O } C) Ln Z a) � N U In Z O U ILL U N W IL o In W Q tY Q a O N SPRI- Fremont D-0053465 - 05-31-2016 HLLUVIOSO 05-31-2016 APATEL SOLAR -E4 kid C a r f LLI w o o N W 4a� > N a M m a � - 3 0 Z = ' _-.._-._-.___...__.._._.._.,....___.__...._...__, Accessories I. -•--------•-! EirKien curve SUNNY BOY SOOOTL Us -22 24pVoc-•--:•-----•_.__._, I / / ►� PENTAIR , - Ir +• '•' i 6 TYPE 3R SCRENf.O.FPTRi Lf}SII E. �i i -R C Zo O I- ¢ cc Ct m o o a f f Z w � S g i 98 - _ _ .___ _ _-___ __ _ .. _ _ _ - speer /w e� � RSd85 uJeAoce } ul dl g 'I � D@ �a:�-.•'ryy �E j r1(K ._. U N J ¢ ' -" 96 -. - - r 4 .n.ea I svrD' A4U5.10 D WS -10 SCREW COVE TYPE 3R R T �.�..:�:yk;.,�,,^� 0 a. a I 94 - - - APPLICATION 4„ 0 2 _ i Use this enclosure with or without knockouts in outdoor n - 9 I Fon cif for 5B 3000/3E00/ „ I 4060/SOoonus22 _ FAnKnoz-io - - -- - applications as a wiring or junction box. REVIEW FEATURES REVIEWED FOR COD COMPLIANCE ANCE !� ea u°;v„- vsvl __Y - - Drip shield top and seam -free sides, front and back RR p 1 ) - Iw;v .4a0v1 n as ; _I Slip-on removable cover fastened with plated steel sc'U�alt%i p,P s6 _ -__-•• Eb4s0w -7'C bottom edge I. 17 t Handles on larger sizes (see table) I 0.0 02 0.4 0.6 0.0 1.0 i •Standard feature- O Optional feature -Not ovoiloble ) Embossed mounting holes on back of enclosure 1 0olpotpavor/ L.._... .... _. Roledpovmr _.. Data at nommolconditlonsProvision Knockouts in bottom of 16 and 14 gauge enclosures for padlocking No gasketing Sunny Boy5000TL-US Sunny Boy6000TL•US Sunny Boy70DOn-US Sunny Boy7700TL-USSPECIFICATIONS 208 V AC 240 VAC 208 VAC 240VAC 208V AC 240VAC 208 V AC 240 VAC i - 16, 14 or 12 gauge galvanized steel W 6300 W 7300-W BOOR W FINISH �� �600V EEF,,, rr115300 600 V 600v 600 V ANSI 61 gray polyester powder paint finish inside and out overpretreated 2io-aeoV 245-480V 270-480V)25 surfaces.v5=aaov 50OV 12s 500'V 125-5WV' 125-500:yACCESSORIES 125V/ 150V 125V/ 150 V 125 V/ 1'50 V 125 V/ 150 V See also Accessories. 36A/15A 30 A/ ISA 90A/ 18A 30A�. 18 A - Industrial Corrosion Inhibitors 2/2 Electric Heater Grounding Device 4550 W 5000 W 5200 W 6600 W 6000 W 7060 W 6656,W 7680 W Mounting Bracket Kit F fn _ Touch -Up Paint U) Z 4550 VA 5000 VA 5200 VA - 6000 VA 6000 VA 7000 VA 6650 VA 7680 VA >- 208 V / s 1240 V / • 208 Y / • 240 V / 0 208 V / • 240V/ 208 V / 240 V/ 0 INDUSTRY STANDARDS BULLETIN:A9OS3 U) ' + 183-229V 211-264V 189-229V 211-264V 183-229V 211 -264 V. 183-229V 211-264V UL 50,50EListed;Type3R;FileNo.E27525 L Q 60 Fu 59.3 = 60.5 -Hz 60 Hz/ 59,3 66.5 Hz 60,Hz/S9.3 - 60.5 Hz_ 60 Hz/ 59:3 60.5 Hz, cUL Listed per CSA C22.2 No 94; Type 3R; File No. E27525 U u 22A 25A, 29.2A 32A NEMA/EEMAC Type 3R Z J r --t O Q wU IEC 60529, IP32 Q> o_ C N w 1/2 1/-2 1/2 1/,2 � 2 O n1 <4% _ <4% <4% <4% Standard Product Q O Z = U) rLL-r Y J O fV Q n. cc ¢ U w Q (f it � } 11a1G> 1 Qi A fGl(�il ftut�il it fiDlfa� idT11 ID Sit�ul 97.2% 97:6% 97.0% 97.A% 96,8% 96:8% 96,8% 97.3% = 0 O F a 96.5° 97.0% 9615% 97.0°a 96.5% 96.5% 96.5% 96.5./ W L O a p MR44 4.ODx4.00x4.011 A - 1.88 2.00 B -C 102 x 102 x 102 - 48 51 W F- " J MR44 6.00 4.00x4.00 A - 1.88 1.06 B -C p + ,z•, _q I- Q 152xl02x162 - 48 27- - � W- rU.- � o - -- ----A1TR44 12.00x4:00xL:00 A - 1.88 1:06 B -C U a 305 x 102 x 102 - 48 27 O U A6R64 6.00 x 6.00 x 4.00 A - 2.25 1.06 B -C -D U LLI 152 x 152 x 102 - 57 27 ko J W ABR64 8.00 x 6.00 x 4.00 A - 2.25 1.05 B-C•D L9 ,/IV 203 x 152 x 102 - 57 27 uj ABR84 8.00 x 8.00 x 4.00 A - 2.25 1.06 F -G -H -I 203 x 203 x 102 - 57 27 490,/519/185 (19.3%'20.5/7:31 A18R84 10.00xB.00x4.00 A - 2.25 1.06 F-G•H-I m u 187/297/ 190. (7.4,/ 11.7 17.51 254x203x1D2 - 57 27 617 / 597 / 266 (24:3 / 23.5 / 10.5) A121184 iffd 8.BOx6.D0 A - 2.25 1,06 F -G -H -I o 370 / 240 / 280. (14..6./ 9,4 / 11.01 305 x 203 X102 Al OR104 10.01)x 10.00 x 4.00 A - 57 27 - 2.25 1.06 C -O -E -F -G ¢ 24 kg (5,3 lb) / 3.5 k9 9181b) 254 x_254 x 101 - 57 27 0 27 kg (§0!1a) / 3.5 kg. is Ib) Al2R104 12.00 x 10.00 x 4.00 A - 2.15 1.06 C-044-6 -40. C...+60°C(-40°F...+140°F) 305'254x101 - 57 27 Z Al2R124 12.00 x 12.00 i 4.00 A - 2.25 1.06 C -0 -E -H 0 <29'dB(A) <29dB(A) <'21dB(A) <298B(A) 305x305x1D2 - 57 Z7 E <1 W <1 W - -<1 W <'1W, A1811124 18.00xl2.0Dx4.00 A - 2.25 1.06 C -D -E -F -G UI Transfarmerte'ss Transformerless Tronsfarmerless _ Transformerless 457' 305 x 132 - 57 27 > Convection Fan Fon Fon A18RI84 10. 00x18.0Dx4.00 B - 13.00 1.12 A -B -C -D -E -F-13-11-1 w z 457 x 457 x 102 - 330 28 0 NEMAZIR NEMA_3R NEMA 3R NEMA3R A61166 6.00x6.00x6.00 A - 2.25 1.06 B -C -O 152 x 152 x 152 - 57 27 N 0 A11111168.00 x 8.00 x 6.00 A - 2.25 1.06 F -G-11-1 0 ^' 0 203 x 203 x 152 - 57 37 ' - 0/0 0/o 0/0 0/0 A10R86 10.00 x 8.00 x 6.00 A - 1.06 F -G -H -I 2.25 •/0/0 •/O/o 4/o/0 6/0/0 254'203x152 A10R106 10 .00 x I D.00 x 6.00 A - 57 27 - 2.25 1.06 C -O -E -F -G - UL 1741, UL 1998, UL 16998, IEEEl547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 254 x254x 152 - 57 27 OPPORTUNITY SPRI- Fremont PROJECT D-0053465 SB 5000TL-US22 SB 6000TL-US-22 SB 7000TL-US 22 SB 770OTL-US-22 DATE DRAWN 05-31-2016 _ 1 CONTRACTOR SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SOLUTIONS Spec -00263 E DRAWN BY Huuvloso DATE CHECKED 05-31-2016 CHECKED BY APATEL FIGURE A: INVERTER SPECIFICATION SHEET FIGURE B: JUNCTION BOX SPECIFICATION SHEET PAGE 1 SHEET SOLAR -E5 TYPE 3R SE.R!"A-COVFRTYPF3RBOXFSAND FIIClTURIFS EQUIPMENT PROTECTION SOLUTIONS PH 763.422.2211 • FAX 763.422.2600 • HOFFMANONLINE.COM I CONTRACTOR 2 Spec -00263 E FIGURE A: JUNCTION BOX SPECIFICATION SHEET PAGE 2 Onsite Cat Ethernet IntemeVLAN Cable AC Powc Supply System Connection Diagram COLOR KEY R E1r' ) SunPower supplied component or cable Installer supplied, SunPower specified r Optional P� .,PZ 1 SunPower Belden 3106A Belden 3106A Ar•-• Accessory Kit or Cat 5 or Cat S I Y -Belden haim" SunPower Cable I Ethernet Ethernet Belden 3106A. Belden 3106A- Accessory Kit Cable Cable DB9 Adapter I Imorter 1 Isnonm 2 ImeRor n MET system Station Production I RI{S sx RJ{S or RJ45 or PV Meter I Tonnlnai. Terminal Terminal Block Block PV Supervisor Mechanical Data - Plus Enclosure Inverter Compatibility t I' 11111 0, I.I'­Ilitklt, Weight %P«kedlNeighf, lbs Ikg) - I1EL Lu l)3 GCtili rn l attt i� filir �`f ul ILdCn :r. li a, Al2R86 12.00 x 8.00 x 6.00 A - 715 1.06 F•G-11-1 Al2R1116 12.00 x 10.00 x 6.00 A - 726 1.06 C -D -E -F -G Upgrodea6iliy JA.tonnalic Firmware Upgrades 305 x 254 x 152 FCC Part 15, Class A compliant - 57 27 305 X305 x 152 - 57 27 A15R126 15.00 x 12.00 x 6.00 A - 2.25 1.06 C•D•E•F-G vs 381 z 305 x 152 - 57 27 A1611126 16.00 z 1Z.00 x 6.00 A - 2.25 1.06 C-1144-6 ff Pit#$S 406 x 305 x 152 of - 57 27 AIBR126 HAD x 12.00 x 6.00 A - 2.25 1.06 C -D -E -F -G K 457 x 305 x 152 - 57 27 O� AIBR186 III .00xIB.00x6.00 B - 13.00 1.12 A•B•C-D-E-F-G-11.1 457 x 457 x 152 Rs - 330 2B A24R126 24.00 x 12.00 x 6.00 B - 13.00 1.12 C -O -E -F -G 610x305x152 - 330 2B AUR186 24.00 x 18.00 x 6.00 B - 13.00 1.12 A -B -C-1144-6-11-1 610 x 457 z 152 - 330 28 A2411246 24.00 x 24.00 x 6.00 B - 13.00 1.12 A-B-C-D.E-F-6.11.1 610 x 610 x 152 - 330 28 ABR88 8.00 x Ilk z 8.00 A - 2.25 1.06 F-6-11-1 2032203x203 - 57 17 Al2R128 12.00x12.00xB.00 A - 2.25 1.116 C-014-0305x305x203 - 57 27 A15RI28 15.00 x 12.00 x B.00 A - 2.25 1.06 C -D -E -F -G 381 x 3D5 x 203 - 57 27 AlBR126 18.01) x 12.00 x B.00 A - 2.25 1.12 C -0 -E -F-6 457 x 305 z 203 - 67 28 A24R168 24.111)x16.00x8.00 B - 13.00 1.12 C -D -E -F -G 610 x 407 x 203 - 330 28 A18111811 18.00x18.00x11.110 B - 13.00 1.12 A-B-C-D•E-F•G•11.1 457 x 457 z 203 - 33D 26 A2411188 24.00 x 18.00 x B.00 B - 13.00 1.12 A•B-C-1144-13.11.1 610 x 457 z 2D3 - 330 28 A24R208 24.00 x 20.00 x 8.00 B - 13.00 1.12 A -B -C -D -E -F-6-11-1 610x508x2D3 - 330 28 A24R148 24.00 x 24.00 x 8.00 C 12.19 13.00 1.12 A -B -C -D -E -F-13-11-1 6101610x203 310 33D 28 A3OR248 30.00x24.00x8.00 C 15.19 13.00 1.12 A -B -C-044-641 762 x 610 x 2D3 386 330 28 A4811368 48.00 x 36.00 x 0.00 C 24.19 33.00 1.50 A -B -C-1144-6-11-1 1219 x 914 x 203 614 1311 38 AlBRI810 18.00 X 18.00 X 10.00 B - 13.00 1.12 A -B -C -D -E -F -G-114 457 x 457 z 154 - 330 28 A24RIB10 24.00 x 18.00 x 10.00 B - 13.00 1.12 A•11 -C-044•641 610 x 457 x 254 - 330 28 A24R2410 24.00 x 24.00 x 10.00 C 11.19 13.00 1.12E•E6rHcl-- --610 x 610 x-256--- - - - - -310--- -- 33D - - 28 - A3OR24E0 30.00 x 24.00 x 10.00 C 15.19 13.00 1.50 A -B -C -D -E -F -G-114 762 x 610 x 254 386 330 38 A24112412 24.00 z 24.00 z 12.00 C 12.19 13.00 1.12 A-B-C-O-E•F•G-H-I 610 x6102305 310 330 28 A3OR3012 30.00 x30.00 x 12.00 C 15.19 27.00 1.50 A -B -C -1144 -G -N-1 762 x 762 x 305 386 686 38 A36R3012 36.00 x 30.00 x 12.00 C 18.19 27.00 1.50 A-B-C•D-E-F•13-11.1 914 x 762 x 305 462 6116 38 A36113612 36.00 x 36.00 x 12.00 C 10.19 33.00 1.50 A -B -C-044-6-11-1 914 x 914 x 305 462 838 38 A30113016 30.00x30.00x16.00 C 15.19 27.00 1.50 A -B -C -D -E -F-6-11-1 762 x 762 x 406 386 6116 38 A48R3616 48.00 x 36.00 x 16.00 C 24.19 33.00 1.50 A -B -C -D -E -F-6-11-1 1219 x 914 z 406 614 838 38 A4114411K 4.00 x 4.00 x 4.00 A - 1.88 2.00 - 102x102x102 - 48 51 WWI( 6.00 x 6.00 x 4.00 A - 225 1.06 - 152x152x102 - 57 77 ASR64NK 8.00 x 6.00 x 4.00 A - 2.25 1.06 - 2113x152x102 - 57 77 A8118411K 8.00 x 8.00 x 4.00 A - 2.25 1.06 - 203 x 203 x 102 - 57 27 Al OR84NK 10.00 x 8.00 z 4.00 A - 2.25 1.06 - 254 x 203 x 102 - 57 27 AIZR64NK 12.00x8.D0x4.00 A - 2.25 1.06 - 305 z 203 1102 - 57 27 AIBR104NK 10.00x10.00x4.00 A - 2.25 1.06 - 254 x 254 x 102 - 57 27 A1211104NK 12.00 x 10.09 x 4.00 A - 725 1.06 - 305 x 254 x 102 - 57 27 EQUIPMENT PROTECTION SOLUTIONS PH 763.422.2211 • FAX 763.422.2600 • HOFFMANONLINE.COM I CONTRACTOR 2 Spec -00263 E FIGURE A: JUNCTION BOX SPECIFICATION SHEET PAGE 2 Onsite Cat Ethernet IntemeVLAN Cable AC Powc Supply System Connection Diagram COLOR KEY R E1r' ) SunPower supplied component or cable Installer supplied, SunPower specified r Optional P� .,PZ 1 SunPower Belden 3106A Belden 3106A Ar•-• Accessory Kit or Cat 5 or Cat S I Y -Belden haim" SunPower Cable I Ethernet Ethernet Belden 3106A. Belden 3106A- Accessory Kit Cable Cable DB9 Adapter I Imorter 1 Isnonm 2 ImeRor n MET system Station Production I RI{S sx RJ{S or RJ45 or PV Meter I Tonnlnai. Terminal Terminal Block Block PV Supervisor Mechanical Data - Plus Enclosure Inverter Compatibility SunPowerSPRf, SPRm Inverters, Supported PP SafCon and Santerno Inverters Dimensions W x H x D, in (cm) 76(26) X 4.31(111 ) X 3.03(77) Weight %P«kedlNeighf, lbs Ikg) - -1-90 --- g- - Number of inverters Supported UP to_30- -- -- System Conned ionType Wired from PV Supervisor to Customer IAN; Wired from PV Supervisor to (optional) Cellular modem. Enclosure Rating W Mounting Optional Wall -Mount Hardware Available Transmission Range 330 ft (100 m) via Ethernet Operating Temperature Operating: -10 to +60 C Storage: -20 to +80 C Power Source External AC Source (100 - 240 VAC, < 5W) Data Storage 60 Days Warranty and Certifications I I Warranty - 5 -year limited warranty Upgrodea6iliy JA.tonnalic Firmware Upgrades Certifications FCC Part 15, Class A compliant Web Support Browsers Microsoft Internet Explorer® 6.0, 7.0 Mozilla Firefox 2.0, 3.0, Safari 3. 1.1 Login Website www.sunpowermonitor.com SJNPOWER and the SUNPOWER logo ae r,s&. da or r glnared trademarks of S.Poww. Carpawors. 0 February 2011 SunPower Cdpordlon. All rights rmerred. Sped6cdlom iwJuded in this damhea me srbloa to change without nonce. Site Requirements • SunPower SPRf , SPRm Inverters, Supported SatCon and Santemo Inverters • AC outlet • Supported Cell coverage FIGURE B: PV SUPERVISOR SPECIFICATION SHEET sunpowercorp.com Doormen A 001-60505 Rol' / LTR -EN 1I�PERTiNO uli ng Department 2- 2016 ECJ F:� CODE COMPLIANCE .VICWe By: U_ Q Z X kD Lq Ln OPPORTUNITY PROJECT DATE DRAWN DRAWN BY DATE CHECKED CHECKED BY O LO F- rn U c 2 Ow Y J O U L, O In Z rn W n. U En Z O Q U n U N w M 0 - En En O dS N w Q � Q o_ 0 J Q J w SPRI- Fremont D-0053465 05-31-2016 HLLUVIO50 05-31-2016 APATEL SOLAR -E6 � F UJI W o o 3 u o A C) vs L7,- p Zg I- Q to Z O o W ff Pit#$S of < U O a U K /^ O� U � + J Rs 1I�PERTiNO uli ng Department 2- 2016 ECJ F:� CODE COMPLIANCE .VICWe By: U_ Q Z X kD Lq Ln OPPORTUNITY PROJECT DATE DRAWN DRAWN BY DATE CHECKED CHECKED BY O LO F- rn U c 2 Ow Y J O U L, O In Z rn W n. U En Z O Q U n U N w M 0 - En En O dS N w Q � Q o_ 0 J Q J w SPRI- Fremont D-0053465 05-31-2016 HLLUVIO50 05-31-2016 APATEL SOLAR -E6 Ln _ F_$ f in LU 01 o to w p M to > F > m un a � Ln 3< 0 SUNPOWER CORPORATION S U N P W E R� � z � u o c„ Safety and installation instructions -Document 001-14158 Rev S �^ C w o o in In O Z Z F j)Jj � � © --no not stand on, drop, scratch, or allow objects to fall on modules as it may H to ^ w oc u� a Safety and Installation Instructions damage and void the warranty. o = x • Do not place anything on the modules, even for a moment because resulting (United States and Canada) c v a O u residue may damage or stain the glass surface. u � • If the front glass is broken, or the backsheet is torn, contact with any module 1.0 Introduction a� surface or module frame can cause electric shock. This manual provides safety and installation instructions for UL Listed • Broken J -boxes or connectors are electrical hazards as well as laceration SunPower photovoltaic (PV) modules that have the UL logo on the hazards. Installers should remove any such module from the array and product label: contact SunPower for disposal instructions. 1 t Tf NLJ ® . Do not install or handle the modules when they are wet or during periodsof high wind. •: 'Mg D @us _ ao,lt C . SunPower recommends a conservative minimum cable bend radius of equal SUNPOWER to or greater than 40 mm (1.5"). a n �: Y 2 o Contact SunPower if maintenance is necessary. V ! 0' lMPORTANTI Please read this manual /n its entirety before . Save these instructionsl installing, wiring, or using this product In any way. Failure to comply , CIO E C. ,-J .,pi F - L IANC E with these instructions will invalidate the SunPower Limited 2.1 fare Rating Safety and Installation Instructions Warrantyfor PV Modules. The module fire rating is Type 2 per UL1703, 2013 edition and Class C per �y �y:✓� UL1703, 2002 edition. Fire rating classification for any PV system using UL1703:2013 can only establish a fire rating in combination with the mounting United States and Canada 1.1 Disclaimer of Liability system ratings normally found in the mountin s s em inst qs I� I N The Installation techniques, handling, and use of this product are beyond I company control. Therefore, SunPower assumes no responsibility for loss, ' +� damage or exense resulting from Improper installation, handlinuse. 3.0 Electrical Characteristics Building Department This document applies to all SunPower modules ,or I Electrical characteristics of the modoil arell�SCFibedinTable 1below. Each listed in Table 1. 1.2 Underwriters Laboratories (UL) Listing information module contains three bypass diodes &or i motiul- them r um eries fuse 3 a�.' Z Zu l� g This product meets or exceeds the requirements set forth by UL 1703 and rating is 15A. �„ ; 1 ,r, ULC/ORD-03703-01 for PV Modules. These Standards cover flat -plate PV modules �� Z and panels intended for installation on buildings or those intended to be Table 1: Electrical Charaeterist' i j �1 it-- M IAN( O This document includes references to SunPower E -Series, X -Series, and NE freestanding. To satisfy the Listing for this product the modules must be mounted Valtagea curentet Open Circuit M3slmum o H modules. These modules do not have grounding restrictions and all are g g Rated Power Short Circuit t with a rack or standoff structure. The Listing does not include integration intoe Module Rated Power Rated P.- Volta Voc y (W) A da1LJ (At t --r Ln Q Q 0) U F f- rr compatible with high -efficiency transformerless inverters. Vmpp IV) Impp(A) e building surface because additional requirements may apply. This product is not �' vma v Z J U Q LL intended for use where artificially concentrated sunlight is applied to the module. SPRx2z 360 COM loon O w '-' z U Q 360 60.6 5.94 69.S 6.49 SPR -x22-360 600 > li a/ N w r n O �"� O M a- Contents of this manual are subject to change without notice. 1.3 Limited warranty SPP-X21.345{OM 1000 Ir- Q LL O In For the latest US & Canada manual please refer to www.Sunpower.com/PVlnstaH ISuideUS 345 57.3 6.02 68.2 6.39 Module limited warranties are described in full in the SunPower warranty SPR•X23.345 600 r+ 0 co Q d � Q w certificates obtainable at www.sunpower.com. In summary, the Limited SPR -%21-335 - = O U W IQ Warranties do not apply to any of the following: 335 57.3 5.95 673 6.23 600 SPR-%21.335-BLK p } 11 Q Lu SunPower Corporation Modules which in SunPower's absolute Judgment have been subjected to misuse, SPR-xzo327{DM N Lu Z a) � abuse, neglect or accident; alteration; or improper Installation, application or ]000 �- � .-I Q www.sunpower.com removal. This includes, but is not limited to, installation, application, or removal SPR -)CIO -31700 20-317 327 57.3 5.71 67.6 6.07 6 �_ _ r I by_any-party-other-than.a SunPower-authorized dealer; non -observance -of- SPR-X20327-6Uf_ 600 SunPower's installation, user's and/or maintenance instructions; repair or SPR -X22-275 275 44.8 6.14 52.7 6.54 600 W - modifications by someone other than an approved service technician of SPR•%21-25S 255 42.8 5.95 51 6.3 600 U Lu SunPower; power failure surges, lightning, flood, fire, accidental breakage, or 1.p w SPR -X20.250 -11M 250 42.8 594 50B 6.2 600 other events beyond SunPower's control. Ln SPH -X21-245 245 42.8 5.72 509 6.08 600 In SPR -X19.310 2.0 Safety PrecautionsSPR419-370BLK 310 57.3 5.41 67.2 5.82 600 no u Before installing this product, read all safety instructions in this document. SP11419-240.111.1( 240 42.8 5.61 50.6 1 5.98 600 SPR•E20440{OM 440 1 72.9 6.01 86.5 6.5 1000 m � DANGER! Module interconnection cables pass direct current (dc) and 7PR-E20435{OM 435 72.9 5.97 85.6 6.43 1000 are sources of voltage when the module is under load and when it is SPR439-410{OM 41.0 719 5.62 853 6.01 1000 exposed to light. Direct current can arc across gaps and may cause SPR -E20327 600 P g 9 P y 327 54.7 5.98 64.8 6.46 Ln injury or death if improper connection or disconnection is made; or SPR-E70327{OM IOoO Z O a if contact is made with module leads that are frayed or torn. Do not SPR -E19 320 azo 54.7 5.86 64.7 6.24 600 connect or disconnect modules when a current source is energizing SPR -119.315 315 54.7 5.76 WA 6.14 600 ; the conductors. Modules may contain high voltage when SPR419.310{OM 310 54.7 5.67 64.4 6.05 1000 w ZO SPR -E38295 COM 295 54.2 SAS 633 5.83 1000 interconnected with other modules. !i SPR -120-245 245 40.5 6.05 4119 6.43 boo u m N . All installations must be performed in compliance with the National Electrical SPR -E73235 235 40.5 5.8 48d 6.175 600 D Code (NEC) and any applicable local codes. SPR-13oNE-Buc 230 40.5 s.6a 48.1 6.05 1 600 . For Canadian jurisdictions, installations shall be in accordance with CSA C22.1, _ Safety Standard for Electrical Installations, Canadian Electrical Code, Part 1 3.1 Bypass Diodes Document 001-14158 Rev S • There are no user -serviceable parts within the module. Do not attempt to OPPORTUNITY SPRI- Fremont PRO]ECT D-0053465 P/N 100345 repair any part ofthe module. 1 For all models the Maximum System voltage for IEC standards is 1000V and • Installation should be performed only by qualified personnel. maximum series fuse is 15A. For models not shown here, please contact SunPower DATE DRAWN 05-31-2016 technical support or visit www.sunt)ower.com. Electrical parameters are measured at Standard Test Conditions (STC). DRAWN BY HLLUV10SO ® 2015 SunPmver Corporation. All ritlhts reserveJ. SperiOcalions included in this manualarc auhje 1 to change without notice. page 12 DATE CHECKED 05-31-2016 CHECKED BY APATEL FIGURE A: MODULE INSTALLATION MANUAL PAGE 1 FIGURE B: MODULE INSTALLATION MANUAL PAGE 2 SHEET SOLAR -ET r M F- ars =, IT u b w o o m a LU N om e to v o 5 > > rn T SUNPOWER� SUNPOWER� in 3 a o °bt SUNPOWERCORPORATION SUNPOWERCORPORATION � Z z u o W �t Safety and Installation Instructions -Document 001-14158 Rev 5 Safety and Installation Instructions- Document 001-14158 Rev S o C, o in to &b WSi OU V UY 1 M O h�F t F m Z W i Bypass diodes are factory installed and are not user replaceable. The diode 5) SunPower modules may also be grounded using a WEEB 9.SNLground clip in Figure 1: Mounting locations for SunPower modules l� J Q 2 o Uw configuration for 96 cell modules is 2 diodes for 2 strings of 24 cells in series, plus between the module and supporting structure. This combination is secured 1) FrameeM0W.: SecOPe the module to the structure using the factory L o x x " g one diode for a single string of 48 cells in series. For 128 cell modules, the with a 1/4" stainless steel rivet or a 1/4-20 by 3/4" zinc -plated bolt with Bl E- Cl a1 mounting holes. Four 1/4" stainless steel bolts, with nuts, washers, and lock v a g configuration is 2 diodes installed for 2 strings of 32 cell in series, plus one diode zinc -plated K -nut torqued to min. 6 ft -lbs to secure the module to minimum I I- a washers are recommended per module; tightened to a min. torque of 10 in- o U for a single string of 64 cells in series. The diodes are one of the following ratings; 12 ga. G90 coated steel orZ-purlin, either painted or unpainted. The WEEK lbs. Refer to Table 4 for the module dimensions and hole locations. This° 1. Schottky type, 15A, 45 Peak Inverse Voltage (PIV) for 96 cell modules. 9.5NL is for single use only. Frame Hole method has been certified by a third -party organization according to UL 2. Schottky type, 20A, 45 PIV for 128 cell modules. Mounting Locations Al 1703. For frame hole mounting, modules must be secured using the holes 3. Schottky type, 20A, 100 PIV for 96 and 128 cell modules. 6) Othergrounding methods may be used in conjunction with a module mounting located at 322mm from the short end of the module for 72 and 96 cell system tested to UL2703. For these installations, the SunPower module and modules and 433mm from the end of the module for 128 cell modules. For frame style must be tested and part of the instructions for the listed ) carport installations the supporting structure has been pre -drilled. For 128 4.0 Electrical Connections mounting product. The SunPower module must be Installed in accordance with these instructions as well as the mounting system's listed instructions. cell modules for carport assembly, modules must ee secured using only the Modules maybe connected in series or parallel to achieve the desired electrical g Y holes located 433mm from the ends of the module and hard a desc(ih@d output provided certain conditions are met. above in Section 4.1, Item S. See Figufe 2 for ca o a�'^tel d tails.v P E ZT I ' " 7) SunPower G5 -frame modules may be grounded through the use of an a ;:;a _, , .-ig SunPower recommends using the same brand/type of dc'home run' connector as InvisiMountTM mid clamp that bonds the module frame to the InvisiMountTM T 2) Clamps or Clips: Mount the module with the IFF c6psn�p•tf eoiring' r s � i , �� C ; IW ® Z _ In � r 0 v In W m in Y Y D Ot � Go v0 o in 0jMLo1 in - oe < - a o U 35 s a $S Table 4: Module SNPOWER ORPDRATIONSUN-POWER and Installation Instructions - Document 001-14158 Rev 5 Frame Detail Switching Devices •1 REVISION YSafety Switches DG321PMB 1201240 Vac General -Duty, Fusible, Single -Throw, continued MaldmamlbrsepovverRatiags0 NEI&AU Sion le-PbaseAC Three-PhaseAC DC Enclost N clesur Ampere Face Type A EDdneueledoar Endosureflaiaprool systam Rating Provision 120V 24W 240V 20V Catalog Number Catalog Number Platform Module mounting and ground hole detail RESIDENTIAL FRAME ONLY 72 CELL MODULE FRAME DETAIL 96 CELL MODULE FRAME DETAIL Frame Profile SIDE FRAME PROFILE S.c Od.Emm -798mm [31.41 ml 754mm 29.7in - 10,19in) r� [ I'7� Drain Holes 127(0 6.6mm Mounting Holest _-- N v Y b ^ o lox0.12mmn E E M iA Ground Hoe;a , ^ L 1046mm [41,2in] — Ax04.8mm - 10.19in] —1002mm [79.din] Drain Hdes �� 12X06.6mm [0.26in] fJwunlin Holes 9 _ — < < < O 1V Q 0 ° Q e o E E E d, E E E lox04.2mm N h ^ (0 1Tin] o t xmm .Ilio I F _ tBn.m :yawn lAard u.u,nm Residential Modules rye-. Cartridge Typo Blades, Three Fuses)-240,Vae x4 bbd — — — — — I.'r � � W c,', s rq C �������� 60 — — — — — 0 D10 ry �"!�� 100 '0 .8 fids% 2oG f�t�lldi 400 H — — 50-125 — DG325FGK00 D ?�?.+ FX1G H — — 75-200 — DC326FGKG0 D I(Q(?i<s.? �� Cartridge Type—Four-Wire (Three Slades,Three Fuses, S/N)-120!240 Vac MRTI(+lO �r VV Department `� 2016 END FRAME PROFILE �^ GroundH.6, (BOCkVjV) ath H — •1.1/2-3 3-71/2 — DG321NGB D e F 1 D FOR' 60 H — 3-10 7-V2-15 — DG322NGB DGf MB ODE COMPLIANCE r [Front V'Krvs'j d6uun -�-� Method 1: 11.eorl ♦ Frame Nok Locations r r 46mm [Front View) (1.Bin] L _ E_ �� s= 12 nm i�nni y 100 H — 7.1/2-15 15-30 — DM23NOU DM23MB Reviewed 200 — ,_ — H 15 25-60 DG324NGK DlD24NRK 400 H — — W125 — DG325NGK DM25NHK 1300 H — — 75=200 — Dp26NGK DC326NfIK Vac General -Duty, Non -Fusible, Single -Throw DC322UflB 1201240 _ Maximlm Horsepower Ratings - NEMA1 WEN43H Ampere Siegle-PhasoAC Three -Phase AC DC Enclosimindoor Enclosure,Aain roof System Rating 129V 240V 240V 25W Catplog Nomher CatalogNarieer Two-Pole,7Wo-Wira (Ttnro Blades) -240 Vac 30 2 3 — — DG221UGB0' DG22IURB0' 60 3 10 — — DGZMGBq) DG7QURB0 100 — 15 — — 6MQ3UGB0' DG213URB0 200 — — — _ 00 Three-Pole,Three•Wire(Three Blades)-240Vao e b b 30 2. 3 7-1l2 — DG221UPBO DG32IURB,O. / / 60 3, 10 15 — DG3MGB0. 11=111180a-- 4 4w 30 — DG323UGB0' DGZIUfl80 2.010— 15 .60 — OG324UGKO DG324URV9 400 — — 125 — DG325UGK0 :DG325UBK0 600 — — 200 — DGMGUGK0 DGNURK© LU F - !2 !2 U) U Q Z _ Q O, r -t O0 Q O Q 1: Ur w F ,..r o Ga _ to F I � Q O U (L, O to Z 0 F- a ILL Ncl� W M CL o oi3 w Q F ULU p Q RESIDENTIAL G5 FRAMEONLY • • •,FRAME)LU Residential Modules 72 CELL MODULE (NO MOUNTING HOLES) 96 CELL MODULE (NO MOUNTING HOLES) SIDE FRAME PROFILE 1 Alit rsaoomm -["''ant—j E € 46mm to+4mm _[4i•tar.i� E— wgo,s. rte ��smm sem' v., END FRAME PROFILE ,ts ggoon so tim I'Iwni u•+ in _ U W w w T_ mmm im" • • COMMERCIAL (SILVER FRAME) MODULESONLY, 96 CELL COMMERCIAL MODULE 128 CELL COMMERCIAL MODULE SIDE FRAME PROFILE Notes 4x 04.8—�•'-1046mm I47.21n1 � 1002mm [39Am DrainHoles 1 � ln] ar,2aa mml: dw 102.0— !.harm Llint (•im. X11 Maxim rnhpratirgsappiyonlywhendual:elerr�ant.tirrod laytusacaraused. 0 iceflity-wirecatalog numbers balm - 0 Solid neutral bars are not included.'Order sepaatdy fromtahle on PageV24145. m E d o _ Commercial 12X . 61n)"11 ♦ ♦ Mounting Holes t a`, 8x 04,2mm o �, e, [0.17ht1 E E E E Gtuu:id Hut m E E m = 4X 13 6.10 [o.241n] ♦ stecking Plus Back Vlesv) 398nun [15.7in1 (Front View) " m nd.t ♦ ♦ ras.a;naltads Md E E a r P&Ift R rz� t sr:amsnnr +L(.♦ - sya :rvsu 1 tFtmtsk,s1 ��� i " - 'v'�i t,a�n . '�`"' .,.+da With Stacking Pins 0 WARNING! Switch is not approved for service entrance unless a neutral kit is installed 0° Use three:wire catalog nuab&S below. 0 Drill adtoa¢eptfield installed neutral kits. All general -duly are irldvidmlypackaged Accessories are'limted in scope on general -duty safety switches. PageV2T1-15 for availability. In addition, clear line shields one available as an aftcessmy on 2"GA-general-duty switches. Catalog Numbers 200Am 70-7759-11,400A =10 063-8, 600A=70,11VA-0. Z p .. (JIEModules > W 0= a o ry � z J E o 12 U � n F = 3 v END FRAME PROFILE lo 1 -am m7 � -_ 3.2mm [0.13IN dFmm[1 tiinl McthuJ 1: ♦ Fmmc Nok tocaitons 3ammlarm. een�lt.wnl EE c r t 1 G�+'"2'" r 7 dint OPPORTUNITY SPRI- Fremon[ PROJECT D-0053465 ' - Volume 2—CommerdalDistribution CAO810oo03E—Febmary2o12 vmweaton.com V241-27 DATE DRAWN 05-31-2016 DRAWN BY HLLUVIOSO 0 2015 Su,P°wer corporation. All rights reserved. Spvdfim lions included in this manual am subject to change without notice. Page [ 5 DATE CHECKED 05-31-2016 v j CHECKED BY APATEL y FIGURE A: MODULE INSTALLATION MANUAL PAGE 5 FIGURE B: AC DISCONNECT SPECIFICATION SHEET SHEET SOLAR -E9 GC '^ _ a f Ln �-+ i p t� I M 3; Er' C U P E R I I 1 `� O LU o 0 0 128 102015 KUP-L-TAP® (IPC) InStiabon Piercing (Dual Ratedj Contact Us r' "'+" Building Department � j e EVI 4 ®(� • �"lrTx�;` Z o K U = C v W 9 ! 2016V b �IV j;sz i ¢ O O W Aovanced Search �, dl�It O f _ M g _ � �g FOR CODE COMPLIANCE a 2 6 RXREVIEWED o� Home Lo Login Help 9 P � (� Reviewed By: u IE About Us la ILSCO Product Catalog KUP-L-TAPO (IPQ Insulation Piercing (Dual Rated) O Mechanical Home > ILSCO Product Catalog > Insulation Piercing > KUP-L TAP® (IPC) Insulation Piercing (Dual Rated) Insulated MechaNcal O Compression ED Grounding 91 Power Distributlon Blocks ' r± Solar Connections El SPINBoI5 +O Underground O Insulation Piercing _ KUP-L-TAP® (IPC) ., Insulation Piercing (Dual Rated) " El Heatshrink IB Tools a Specialty 0 Wire Management Accessories Create Catalog Cut til Sheet H to IB New Products • Kup-L-Tep(R) insulation piercing connector. U) • Body is molded from tough, resilient glass-filled nylon. to O 0 Reference • UL 48BA/B 90• C Listed and is CSA Certified. Q ILSCO Fillip Book Catalog • For use with stranded conductor Class B orC Ln - - Contact Us Compact design. •Tin Plated copper contact teeth and pre-filled with silicone lubricant. ¢ z J �j O, U H • Removable end tabs. 1-4O LU rQr Z U • Dual Rated for Copper and Aluminum Conductor. Q > LU � UJ • UL File E6207 - '-'t O H fV d a- = O r In hems Per Page 26 • Compare Creole Cul Sheet Z = Y NO OSS Q a IY U LLI Q = O n I' V, w O N o ~ 01 ? J Compare/Cut _ Item IO Figure Conductor Range Conductor Range Voltage Hex Size Standard NAED/t *-I r- Q Sheet Number Main Tap Package Numb Quantity t7 .-i ne _ U W o IPC-1/0-2 4 1/AA A'WG 2-8 AWG 30D{480 GROUNDEDY-SYSTEM)---1/2-- 12-07036695: (' a IPC M-6 O 2" 4/0-4 AWG 6-14 AWG 600 - 1/2_ 12 07836695: � U U U LU 0 IPC410-210 1 4/0-2 AWG 210:6 AWG 600 1/2 8 07836695:tD LU 0 IPC-2504/0 2 250 kcmil-1 AWG 4/0-6 AWG 600 518 4 07836695: Lr? tri 0 IPC-3504/0 1 350 kcmil-4/0 AWG 4/0-10 AWG 300 (480 GROUNDED Y SYSTEM) 5/8 4 07836695: ❑ IPC-350350 3 350 kcm11-4/0 AWG 350 kcmil-4/0 AWG 300 (480 GROUNDED Y SYSTEM) 5/8 4 07836695: u ❑ IPC-500-12 1 500 kcmil-250 kcmil 10-12 AWG 300 (480 GROUNDED Y SYSTEM) 5/8 4 07836695: 0 IPC-500.250 1 500 kcmil-250 kcmil 250 kcm11-4 AWG 600 518-11/16 4 07836695: o i l O IPC-500500 1 500 kcmil-300 kcmil 500 kcmil-250 kcmil 600 7/8-7/8 1 07836695: a e O IPC-750500 1 750 kcmil-500 kcmil 500 kcmil-350 kcmil 600 7/8-7/8 1 07836695: ° U) Z O to E Contact Us Pdvacv Poficv ILSCO is Registered in the U.S. Patent and Trademark Office _ 01991-2015 COI Technology All Rights Reserved �. 1LSC0 - � LLI o Phase 2 4730 MADISON ROAD W CINCINNATI, OH 45227 8 513533.6200 U - B00-776-9775 ° - z ' OPPORTUNITY SPRI- Fremont - PROJECT D-0053465 DATE DRAWN 05-31-2016 http:/Mww.ilsoo.con/e2wShoppingCctWog.aspOWentlo--31000125428parentLink=2100001183:3100012541:3100012542 1/1 DRAWN BY HLLUVIOSO ' DATE CHECKED 05-31-2016 CHECKED BY APATEL FIGURE A: INSULATION PIERCING SPECIFICATION SHEET SHEET SOLAR-E10 lt:?A 0 0 X00 Loo 0 R E. 9 DESCRIPTION I DATE I D8 I MSP SWAP ONLY & ADDMON& MEGHANA JAIN AC MCONNECT 1 M 5.56kW GRID TIED PHOTOVOLTAIC SYSTEM 11195 YORKSHIRE CT CUPERTINO, CALIFORNIA 95014 SOLAR INDIVIDUAL PERMIT PACKAGE I STRING DIAGRAM a 0 LE a �Q m < A2 10 co) 0 0 -n (DL 0 C r, c) n 0 C= CJ M 0 ;u m o 0 3 > F 0 S"U'NPOWEIZ 0 0 R E. 9 DESCRIPTION I DATE I D8 I MSP SWAP ONLY & ADDMON& MEGHANA JAIN AC MCONNECT 1 M 5.56kW GRID TIED PHOTOVOLTAIC SYSTEM 11195 YORKSHIRE CT CUPERTINO, CALIFORNIA 95014 SOLAR INDIVIDUAL PERMIT PACKAGE I STRING DIAGRAM a 0 LE a CORPORATION, SYSTEMS 1414 HARBOUR WAY SOUTH RICHMOND, CA 94804 (510) 540-0550 CA LICENSE #890895 �Q m < El (D (D ::E 0 -n (DL 0 C X00 n 0 C= CJ M 0 ;u m o 0 3 Z 0 S"U'NPOWEIZ CORPORATION, SYSTEMS 1414 HARBOUR WAY SOUTH RICHMOND, CA 94804 (510) 540-0550 CA LICENSE #890895 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-1812 1195 YORKSHIRE CT CUPERTINO, CA 95014-4967 (362 11 009) SUNPOWER CORPORATION SYSTEMS RICHMOND, CA 94804 OWNER'S NAME: JAIN PUNIT AND MEGHANA TRUSTEE DATE ISSUED: 04/21/2016 OWNER'S PHONE: 408-718-1862 PHONE NO: (941) 720-3850 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class B. C-10, C-46, A Lic. #890895 Contractor SUNPOWER CORPORATION SYSTEMS Date 02/28/2017 X BLDG —ELECT —PLUMB MECH X RESIDENTIAL COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing _ with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: INSTALL (N) SOLAR ARRAY SYSTEM FLUSH -MOUNTED I hereby affirm under penalty of perjury one of the following two declarations: DIRECTLY TO THE ROOF - 5.56 KW AND 17 MODULES r. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this Sq. Ft Floor Area: Valuation: $5000.00 permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction, and hereby authorize 362 1 1009 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the applicant understands and will comply with all non -point source regulations Municipal Code, Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. :p�eQupertino S' na it Date 4/21/2016 Issued by: Alex Vallelunga Date: 04/21/2016 OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is t. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed Signature of Applicant: contractors to construct the project (Sec.7044, Business & Professions Code). Date: 4/21/2016 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I will permit is issued, maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous shall not employ any person in any manner so as to become subject to the air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and exemption, I become subject to the Worker's Compensation provisions of the the Health & Safety Code, Sections 25533, and 25534. Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. . - Vtr Mo i e err ' APPLICANT CERTIFICATION Date: 4/21/2016 I certify that I have read this application and state that the above information is CONSTRUCTION LENDING AGENCY correct. I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance relating to building construction, and hereby authorize representatives of this city of work's for which this permit is issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code, Section 9.18. 1 understand my plans shall be used as public records. Licensed Signature Date 4/21/2016 Professional PROJECT ADDRESSAPN r kcg- ks:Ce CT , C . C/� 9sotu moo, # -.00.9. :" lig OWNER NAME P416!lt. PHONE . . E-MAIL, STREET ADDRESS .. CITY, STATE, ZIP C 0 FAX CONTACT NAME PHONE \ d �15�3 . rp2 E-MAIL, • - Com - STREET ADDRESS ' CITY, STATE,. ZIP _. FAX . ❑ OWNER ❑OWNER-BUIIDER ❑ OWNERAGENT v CONTRACTOR ❑ CONTRACTORAGENT . ❑ ARCHdECT 0 ENGINEER - ❑. DEVELOPER . - ❑ _TENANT CONTRACTOR NAME - boc )c LICENSE NUMBER U q :9 LICENSE TYPE - BUS. LIC # � l �- FAX COMPANY NAME .. .. _ .. Svri�c�rS?. . Co`riQ . cS`QST�S �S. EMAIL Cor STREET ADDRESS : - CITY, STATE, ZIP. ' ' : Fc e+rc,.k:; L1 .. Cf' -15.3 g. ' PHONE Slo.Zo3', (02 \'k- " .. ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME ... E MAII _ ... r FAX . ... STREET ADDRESS' .. mob\e: S CITY, STATE, ZIP : �cxSe,_ : CA q S 13 `'\ ' . PHONE _ i:\c • ; -kl-\ L USE OF 9 SFD Or. Duplex - ❑ : MUIti-FaI ill PROJECT IN WILDLAND - PROJECT IN ❑ CommercialURBAN INTERFACE AREA .. El. Yes " E NO FLOOD ZONE. 11 Yes ❑-NO STRUCTURE: l� SOLAR PANELS❑ ELECTRIC VEHICLE.CHARGING STATION _ " ❑" SOLAR -WATER BEATING ❑. OTHER: FOR SOLAR PANELS: NUMBER OF PANELSIUNITS: KILOWATTS(CO RCIAL NLY): 'TOTAL VALUATION: S OHO DESCRIPTION OF WORK , _.. ear✓ ice-.:. iYtc� r,��.�2.S 5� RECEIVED BY: By my signature below,"I ceitify to each of the following: - I. am tlie.property owner or authorized agent to act on the property owner's behalf. I have read this application and the information.I have provided is correct. I have read the Description of Work and verify it is accurate: I agree to comply with all applicable local ordinances and state laws relating to building co on. I. authorize representatives of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicant/Agent: :Dater S - SUPPLEMENTAL INFORMATION REQUIRED' Q OFFICE USE ONLY a W OVER-iHE-COUNTER 0 EXPRESS - _W . STANDARD .. Q,J OJ ❑ LARGE . a MAJOR PVApp_2011.doc revised:03/16/11 ,n CODE INFORMATION ? o ' W. m N s LR PACKAG'E�,­2013 I DI ID AL PER(CRC) N I z" > co wIT-SO APPLICABLE CODES, LAWS AND REGULATIONS CALIFORNIA RESIDENTIAL CODE CRC . B 2013 CALIFORNIA BUILDING CODE '(C C) a,: � p is U, M B 2013 CALIFORNIA FIRE CODE (CFC) O 0 0 tI a ' � Ln x .0 �g • 20 RN - 13 CALIFORNIA ELECTRICAL CODE (CEC), C7 i J EGHANA: JAI N THE INSTALLATION OF THE PV SYSTEM a 0 uo. qr U v a SHALL CONFORM TO THE REQUIREMENTS •' OFTHE 2013 CBC AND 2013 CEC, ARTICLE.. 690 AND ANY OTHER APPLICABLE G 1E.D P OTOVOLTAIC S ARTICLES OR STANDARDS. INSTALLATION SHALL BE PROVIDED (.CALIFORNIA 5 5-6kW R1:D.-T O LICENSED CpNTRACTOR(B, C-46, OR C-10) RECEIVED:VICINITY MAP: PROJECT LOCATION . �,r 1 119 5. YORKSHIRE CT �'�'`� _ ECKIE PrP E RTI N O., CALIFORNIA 9 5 014 :�Y pp L F.. .5.f s .•, DAT E _ SS P E T �' ¢¢¢¢ ANNIN I i 'RTliOFF 0IM Ci--- E `C 1Ln En s H ' A. Q' � W Z. ru� � W tto 0, 0, Ce LL, 0 V' a J) - .. z= Q CL O U 17 W' ' :SYMBOLS SHEET INDEX W:Ln ..ABBREVIATIONS: ' c� a. F� Z � ' .. At .. - ELEC: Electrical ,• .. EL ' Electrical: Outlet - MAX. Maximum _ � � M.D.F. Medium Density Fiberboard y SB .. Starbucks .. S.C. ' Solid Core % Seat Cover •. .. .. - - - - ., SOLAR ARCHITECTURAL A:B: A:C'.T. A.D. Anchor Bolt • Acoustic . Ceiling .Tile Area. Drain E.P.B.' EQ. Electrical Panel Board - Equal. - MECH. Mechanical. _ MEMB. Membrane ..SCHED,. Schedule SECT. Section- .. - _ _ -e I��I� II�O V O ' ADJ: - Ad•acent, Adjustable I J .EQUIP.' E.W.C. Equipment - Electric, Water Cooler MEZZ. Mezionine MFR. Manufacturer S.E.D. See Electrical Drawings SFD Smoke Fire Damper 2 1. - .. : NEW FINISH GRADE' _ 'SOLAR -AO �, .. !n A:F.F. Above Finish floor EXIST. Existing _ _ MIN. Minimum • _ SHT. Sheet . DRAWING NUMBER GROUP' : STANDPIPE CABINET o' DRAWN ®45' ( ) �ti,. -�i"? ,.}��n _ i,•P' . _, p ^ •' p(,��Id�nQ� WP'.��1 6111�i1 r� -, N AL. Aluminum EXP.' Expansion MIR. Mirror, - SIM. Similar NUMBER DISCIPLINE PREFIX r� .FIRE TI NG RADE (SHOWN _ �,• UT' T SOLAR A1. K; Lf) A:T.C.. • B8. -' Acoustic Tile Ceiling Bulletin Board EXP. JT. Expansion Joint .. MISC. _ Miscellpneous M.O. Masonry Opening S.h1.D.. See. Meclionical- Drawings FSC. 68.5 IZ AL Y) HORIZONTALLY) HOR ONTALL C:, �. .SOLAR=A2 _ r�,, .; CTURAL DETAIL BD. Board 'Between ��,. F. D. Exterior' - Floor Drain MOD. Module . • S.M.S.. - Sheet Metol Screw SP Sprinkler - REVISION CLOUD :AROUND WALL HUNG CABINETS OR. B SHELVES � .. 'p''�,,� �y tta'. BETW.' BLKG: Blocking. F. E. Fire Extinguisher - M.S. Machine ScrewPlumbing MTD. Mounted S.P.O. See Drawin s 9 f -REVISION PROPERTY LINE f• �9� 9 .$,.�� cr°i BM., Beom• F.E.C. Fire Extinguisher Cabinet MTL. Metal. lessSteel S.S. Stainless Steel _ ., COUNTERTOP q _ ,6z>fl B.O. BOT. Bottom Of. Bottom F.H. F.H.C. Flat Head Fire Hose Cabinet (N) New - _ wi Ps S.S.D. - See Drawings S.T.S. Self -Drilling, Self -Ta ing 8. - }p� FOR Crr�a� �����'" ��� B.P. BFIG. _ Backing Plate' BearingFUR. FIN. Finish Floor N.I.C. - Not ,In Contract NO. Number NOM. Nominal - Sheet Metal Screw _ STD.. Standord. ' S'fL. Steel' MATCH LINE,.SHADED PORTION,— —�j `-' IS -THE SIDE CONSIDERED—N. OWNER FURNISHED ITEMS (NOT IN. CONTRACT) yi,�h.. TOP WA 0 OF LL `�( •- ��VIEWED - t o •BTWN. _ Between. .. FLUOR. F.D.. Fluorescent Face Of N.T.S., Not To Scale - ST_RUCT: Structural '. .. ReVl�u�id �cy. - CAB. CER. CH Cabinet - Ceramic Coat is F.O.S. F.O.W. Face Of Stud - Face Of Wall' Fire - O.A.D. Overall Dimension - O.C. On Center SUSp. suspended TB. Tock Boaid • " WORK POINT.,CONTROL POINT .- ' . ® ACCESS PANEL 5 - .. '13' G TOP_ OF CURB /� .} SOLAR' STRUC STRUCTURAL DRAWINGS O z C.J. Control • Joint F.R.. F.S.. Resistant Full Size O.D. outside Diameter THK.' Thick .. - to a ,rL CL. Center Line' _ Closet FURR. _ Furling OPNG. Opening OPP: Opposite .. PP T.O. - Top Of T.O.C.To Of Concrete p �CLG.. Ceiling �, Future . O.F.C.I. Owner Furnished/ Installed _ T.O.S.Top -0f Steel - SECTION�3a 3 SECTION IDENTIFICATION M DIMENSION LINES - S? TOP OF PAVEMENT SOLAR-S1�S2 MOUNTING DETAILS uJ u in -CLR. `C.M.U. Clear Unit GA. Gauge Contractor O.F.O.I. Owner Furnished/ TSO Telecommunication. Service Outlet' A3.1 SHEET WHERE SECTION IS DRAWN _ _ce SOLAR=S3. STRUCTURAL CALCULATIONS I COL. .CONC. - Concrete Masonry Column' Concrete GALV. G.B. G.D. Galvanized Grab Bar Garbage Disposal Owner Installed O.F.V.I. Owner Furnished/ TTD . Toilet Tissue Dispenser TYP. Typical - - DETAIL - SOLAR -S4 -S6 INVISMOUNT. DATA & SPECIFICATIONS. =_.CONST. 'CONT. Construction - G.W.B. GYP. BD. Gypsum Wallboard Gypsum Wallboard Vendor Installed . 0. H. Oval Head - U.O.N. Unless Otherwise Noted 3 DETAIL IDENTIFICATION A9.1 CENTERLINE OF COLUMN OR STUD • OFFSET'FACE - - - Continuous O/ Over UP. UpperI , - SHEET WHERE .DETAIL IS DRAWN} . _ :,;000RD. C.R." ,'-. C.T. Coordinate ColdRolled , Ceramic Tile. H.B. H.C. Hose Bibb Hollow Core -' PAD - Powder Actuated- Device _ PB Push Button. Door' 0 erator p - V.C.T. - Vinyl Composition Tile' y p -. C INTERIOR ELEVATIONS• (;) —t F.O.C. .. IL : - 'CTR _ Counter. HDWD. Hardwood Metal P. LAM. Plastic Laminate VEN. Veneer ELEVATION IDENTIFICATION FACE OF CONCRETE ,� ALIGN FACE - OPPORTUNITY SPRI- Fremont CTSK. Countersink H.M. HR. Hollow' Hour R: Property Line. VER. Verify VEST. Vestibule 4 (UNFOLD ELEVATIONS CLOCKWISE. B A6.1 NO ARROWS MEANS ELEVATION - - DBL. Double H.R. Hot'Rolled PL. Plate V.I.F. Verify In Field. NOT SHOWN.)` PROJECT JE D 00 671 - 51 DCA. _DET: 'Drilled Concrete Anchor- Detail - HT. Heighti g PLY. - Plywood PLYWD.-' Plywood V C Verify. W'th Co sework ' • . A SHEET WHERE ELEVATION IS DRAWN —}. F.08. - EXISTING WALL OR PARTITION SOLAR ELECTRICAL DRAWINGS ,DATE DRAWN-' 04-20-2016 •�zD.F. Drinking Fountain LD. Inside Diameter PT. - Paint .. V.W.C. Vinyl Wall Covering _ _ - i. FACE OF FINISH I - TO REMAIN -'DIA. Diameter I.F. Inside Face ' P.T. Pressure Tr W/ With - - - DRAwN'Bv, HLtuvloso' :DIM: Dimension rns. Insulation PTD. Painted'. W.C. Wan Covering SOLAR -E1 ELECTRICAL SINGLE LINE DIAGRAM. & DISP.., DN. Dispenser Down INT. INTER., Interior Intermediate PTN. Partition Q.T. Quarry Tile WD. -Wood - W.P. Wdterproof{ FINISH FACE, TO FINISH FACE. - EXISTING DOOR TO REMAIN SPECIFICATIONS SDR.: Door INTCM• Intercom QTY. Quantity W.R. Water Resistant A DATE CHECKED -20-2016 04202016' .;DSP, Door Side Panel JAN. Janitor - w.s. wood screw - SOLAR: E2 ELECTRICAL CALCULATIONS. DETAILS. CHECKED ED BYOR APATEL iDTL. ,Oetoil .. ;'DWG. Drawing �.'(E). ' JST. ,hist' Joint R. Radius RAD. Radius Drain. WR Waste Receptacle ' .. PIPE CHASE ISTUDHU:O.N.) _ SP SOLAR- E3—E9 � ELECTRICAL DATA & SPECIFICATIONS .Existing •TT• R.D. • Roof WALL (FACE OF / / ?AGN SHEET " EA. • Each' LCB. Liquid Chalk Board RE: Refer To - - .. - . .. SOLAR -E10 STRING DIAGRAM I-,.EIFS E.J.' Ext. Insulation Finish 'SystemLAM: Expansion Joint LEV. Laminated - Level REQD. Required Resilient RES. Res n - .. - .. .. ."EL. Elevation LT. WT, .. • Light Weight RESIL.' Resilient. - - R.H.. Round Head - L.N. Liquid Nitrogen L --:FOOT BOLT Assumed Viniage 3 Os! 10 : C 6 ' 1.1 _ASCJ A'`' -' - r r! - N - FIG.A• MODULE, PLACEMENT AND RAFTER FRAMING DETAIL ROOF 1 .. LEGEND E 1/':"x3%' . W o '-1 o N a, g 6'-11" 5'-6" J. " " 2 x6. 1%:"x5%" 00 10In 03�m 9'-6" Q > 8'70" J 2''x8'.' EXISTING RAFT R I E �4¢-1-x4--1 5 14'-10" . 3 a m. . a • 2"x4'1- lY4"x3%" 11'-3" 9'-9" a V).. w Q. Q 6'-9.. .. E ' -OR.' X) �Q�iPLIAIlI, 17'-0" 0 W -.9 :. .�C • .. • ATTACHMENT ROOFENT •� C7 .. �. o, a z In ut . . 18'-0" _�Z .19'4 15'-6" R � m '� LU u � � a. Z " . ---- -- RAI L o x . a� � U' 0 w o v u ®. CHIMNEY (n u • ROOF VENT 210' . lO VENT PIPE +�6 U. m inimG ArrGcc L --:FOOT BOLT Assumed Viniage 3 Actual Size " 10 : C 6 ' 1.1 _ASCJ A'`' -' - r r! ¢ .Cl. ;-� f`-1•AI4_iT .. A. 1/':"x3%' -t- w z , 8'=6" 6'-11" 5'-6" J. " " 2 x6. 1%:"x5%" 14'-4". 11'-9".. 9'-6" Q > 8'70" J 2''x8'.' 11 �4¢-1-x4--1 5 14'-10" . i� �a-4- �' f .. .. a • 2"x4'1- L --:FOOT BOLT Assumed Viniage 3 Actual Size " 10 : C 6 ' 1.1 :3 - 24". O.C: �� y � 0.6 i1- 6� 0 e I V ,UMinc� ��p~rfi�n .21lx4" 1/':"x3%' o taCN� w z , 8'=6" 6'-11" 5'-6" " " 2 x6. 1%:"x5%" 14'-4". 11'-9".. 9'-6" Q > 8'70" J 2''x8'.' 11 18'-2" 14'-10" . 12'-0." 15'-9" _ a • 2"x4'1- lY4"x3%" 11'-3" 9'-9" a V).. w Q. Q 6'-9.. .. E ' -OR.' X) �Q�iPLIAIlI, 17'-0" c� W' 0 U >-.d: 12'-0" 9'-9" 04-20-2016 DRAWN BX' 22'-3'' . 18'-0" _�Z .19'4 15'-6" R led '� � ..:. Z " . � U' 0 w ;L10 , 210' . +�6 U. m FIG. B: STRUCTURAL RAFTER.FRAMING DETAIL (NTS) FIG.C: ROOF RAFTER MAX HORIZONTAL SPAN. PER CALIFORNIA SOLAR -PERMITTING GUIDEBOOK 2015 (NTS) 0 o .. z L --:FOOT BOLT Assumed Viniage Nominal Size, Actual Size " 16" O.C:: Non lie Roof -24"• O.C. Rafter Spacing 32" O.C:. 16".O.0 . - 24". O.C: 32" O.C. 'Post -1960 .21lx4" 1/':"x3%' 9'-10" 8'-0" 6'-67. 8'=6" 6'-11" 5'-6" " " 2 x6. 1%:"x5%" 14'-4". 11'-9".. 9'-6" 12'-5" 10'-2" 8'70" 2''x8'.' 1%'xT/."' 18'-2" 14'-10" . 12'-0." 15'-9" 12'-10". 10'-3" . Pre -1960• 2"x4'1- lY4"x3%" 11'-3" 9'-9" 7'-9" 10'-3" 8.'=6'.' 6'-9.. 2"z6" N"x5%" 17'-0" 14'-0" 11'-3" 14'-9" 12'-0" 9'-9" 04-20-2016 DRAWN BX' 22'-3'' . 18'-0" 14'-6" .19'4 15'-6" 12'-6d 2"x4 C'. :. T SIGN " DATE CHECKED 04-20-2016 NOTES' - CEILING JOIST. 1.' THE SITE AUDITOR HAS VERIFIED THAT ROOF STRUCTURE IS STRUCTURALLY SOUND WITHOUT SOF CHECKED BY APATE ' LE F E N CTU _ - ALTERATIONS OR.SIGNIFICANT STRUCTURAL DETERIORATION OR SAGGING.. 2. MEASURED HORIZONTAL SPAN IS SS THAN TABLE 1 SPAN ABOVE, THERE OR O STRUCTURAL scA�e 1/H�I — 11 OIC ' SHEET MODIFICATION IS REQUIRED. BEARING WALL j. -MAXIMUM ATTACHMENT SPACING IS 6' ON CENTER, PLEASE REFER TO. SOLAR -Sl SHEET. SOLAR -A2 0 �n o > W d N O OPPORTUNITY SPRI- Fremont PROJECT �13-0051671 . DATE DRAWN 04-20-2016 DRAWN BX' HLLUVIOSO 2"x4 C'. :. T SIGN " DATE CHECKED 04-20-2016 NOTES' - CEILING JOIST. 1.' THE SITE AUDITOR HAS VERIFIED THAT ROOF STRUCTURE IS STRUCTURALLY SOUND WITHOUT SOF CHECKED BY APATE ' LE F E N CTU _ - ALTERATIONS OR.SIGNIFICANT STRUCTURAL DETERIORATION OR SAGGING.. 2. MEASURED HORIZONTAL SPAN IS SS THAN TABLE 1 SPAN ABOVE, THERE OR O STRUCTURAL scA�e 1/H�I — 11 OIC ' SHEET MODIFICATION IS REQUIRED. BEARING WALL j. -MAXIMUM ATTACHMENT SPACING IS 6' ON CENTER, PLEASE REFER TO. SOLAR -Sl SHEET. SOLAR -A2 RISK CATEGORY. II, V =. 110 MPH BASIC WIND SPEED; EXPOSURE C, O PSF GROUND..SNOW. LOAD, Ss = 2.Og MAX MAX MAX MAX SPACING CANTILEVER. UPLIFT DOWNFORCE ZONE 1 72" 36" 25 psf 28 psf 3901b- 4441b. ZONE 2 36" 1s� 46 psf; . 28 psf 360 Ih 222Ib . ZONE 3 30" 15" 73 psf :' 28 psf- sf475Ib 4751b 185 Ib' DESIGN PARAMETERS WIND LOADS RISK CATEGORY: II EXPOSURE: B OR C MAXIMUM WIND SPEED PER IBC 2012, V: 110 MPH MAXIMUM ROOF HEIGHT, H: 40 FT MAXIMUM ROOF SLOPE: 12:12 MAXIMUM LEAST HORIZONTAL DIMENSION OF BUILDING, L: 50 FT TOPOGRAPHIC FACTOR, kzt: 1.0 WIND DIRECTIONALITY FACTOR, kd: 0.85 VELOCITY PRESSURE EXPOSURE COEFFICIENT, kh: 1.04 INTERNAL PRESSURE COEFFICIENT, GCPi: 0.0 SNOW _LOADS MAXIMUM GROUND SNOW LOAD, pg: 0 PSF EXPOSURE FACTOR, Ce: 0.9 (FULLY EXPOSED) THERMAL FACTOR, Ct: 1.2 (UNHEATED AND OPEN AIR STRUCTURES) SLOPE FACTOR, Cs: PER FIGURE 7-2c (UNOBSTRUCTED SLIPPERY SURFACE) SNOW IMPORTANCE FACTOR, IS: 1.0 SEISMIC LOADS SHORT PERIOD SPECTRAL ACCELERATION, Ss: 2.09 SITE COEFFICIENT, Fa: 1.0 COMPONENT AMPLIFICATION FACTOR, ap: 1.0 SEISMIC COMPONENT IMPORTANCE FACTOR, Ip: 1.0 COMPONENT RESPONSE MODIFICATION FACTOR, RD: 1.5 SITE CLASS: ID LEGEND INTERIOR ZONES ZONE 1 END ZONES ZONE 2 ®CORNER ZONES ZONE 3 FIGURE A: ROOF ZONES PER ASCE 7-10 FLAT ROOF HIP ROOF (70< Q':5 270) 1� IJ /I `?E '-ONlPLIANOE PROJECT D-0051671 yV1F',AJED F0- R CCa GABLE ROOF (6 < 70) GABLE.ROOF (70< 0:5 459) a in 04-20-2016 Reviewed PRAWN BY w 0 0 a, I DATE CHECKED 04-20-2016 Wo �UPE INO u OPPORTUNITY SPRI- Fremont `?E '-ONlPLIANOE PROJECT D-0051671 yV1F',AJED F0- R CCa f � a in 04-20-2016 Reviewed PRAWN BY w 0 0 a, < DATE CHECKED 04-20-2016 V) U) Q V O co 0 0g ` SOLAR -S2 U) � 03 Z U 0 W �e3R Vic: Z v U Q J C 0 0 0 2 dao H m o o w ig Za 3. < U U =�8 = 111 ai M 0 tD = J 0 .i K U u° Ln Wo �UPE INO u OPPORTUNITY SPRI- Fremont `?E '-ONlPLIANOE PROJECT D-0051671 yV1F',AJED F0- R CCa W BY: '�'° /17f�T DATE DRAWN 04-20-2016 Reviewed PRAWN BY HLLUVIOSO DATE CHECKED 04-20-2016 CHECKED BY U) SHEET .. .. SOLAR -S2 U) � Z ~ U Q J QLL U W" Q O CL Lu O U) o V , O rn z M W O NC7 w Z CL ~ z :D d' C7 W 0_ 3. U tD LrI Ln m m Wo �UPE INO u OPPORTUNITY SPRI- Fremont `?E '-ONlPLIANOE PROJECT D-0051671 yV1F',AJED F0- R CCa BY: '�'° /17f�T DATE DRAWN 04-20-2016 Reviewed PRAWN BY HLLUVIOSO DATE CHECKED 04-20-2016 CHECKED BY APATEL SHEET .. .. SOLAR -S2 t_oaa t;aicuiation rarameiers .. fLn Lag Bolt 5trensth 0- W W F -(n Rail tributary width o 00 �. 00 �oOF o. U. �: Ce o Flat roof snow load P f 7.6 sf .� Wind velocity pressure qh - 27: psf O O Z �� 0.3125 inch K m < ¢ o. o. ., Ln M $j Dead Load pd O = 0.49 (Douglas Fir or.equal). - $ t_oaa t;aicuiation rarameiers .. Lag Bolt 5trensth 0- Rail tributary width 2.6. P NDS LRFD o. U. �: Ce .. U Flat roof snow load P f 7.6 sf .� Wind velocity pressure qh - 27: psf Service Loads Bolt diameter; D = 0.3125 inch Dead Load pd 3.38 psf Specific gravity, G = 0.49 (Douglas Fir or.equal). Sloped Roof Snow Load : ps 7.6 p'sf Withdrawal value, VV-=. 258 Lb; NDS Table 11.2.A Wind Load Upward Zone 1 pw_ionel 727.48psf Load duration:factor,:Ccl = 1 ; Section 10.3.2 (LRFD design). Wind Load Upward Zone 2. Wind Load Upward Zone 3 pw_zone2 px_zone3• -49.46. psf -76.94 psf Wet service factor; Cm = 1 ; Section 10.3.3 (Wood in.continuously dry condition) Wind Load Downward pw_down 25 psf Temperature factor; Ct = 1 ; Section 10.3.4 (no sustained temp :> 100°F) . Seismic Load. F P 3.6 End rain factor, Ce g 1; 1 ;Section 11:5.2 (no end grain) Seisimic Load Fp_upper_limit 1.4 foe=Nail factor Ctn 1 ; Section:11:5:4 (no toe nail) Seismic Load �Seismic FP-lower_limit 7.2. __ - Format conve a on f c for, Kf = 332 ;Table N1 (Connections) Load Fp_eon 3.6 Load Combinations Resistance tor; Viz.= 0. 65 ;Table N2 (Connections) . 1.4b Combo.i 10 Of . Time effect factor, X_ ... 1. ; Table N3 (Wind/Seismic) . 1.2D+1.6S+0.5W Combo?' ..5-7 plf 1.2D+0.5S+1.OW :. Combo 3 .74 plf : • :' . 0.90+1.OW ... Combo 4 (Zone .1) :' -65.43 plfW (per inch of thread penetration) 557.28 Ib; Table.10:3:1 0.9D+1.OW Combo 5 (Zone 2) :119.91 plf. w 0.9D+1.OW Combo 6 .(Zone 3) :-190.1.1 .plf .. 1.2D+1.OE+0.2S Combo 11 15 plf .. 1:40 . .. ..... Combo 7 7.4 plf 0 U) '. - 1.20+1.65 Combo 8 ' 14 plf . a rn. p 1.2D+0.5S . Combo 9. 8.5 plf 0.90 Combo 10 4.8 plf : p. � p 1.20+1.OE+0:2S Combo 12 14. -plf, : _• N Worst Case Uplift Zone 1 P WCzo,nei 65 If : P z _ Y J o .0 Worst Case Uplift Zone 2 WCione2 120 plf a �' LU Worst Case Uplift Zone 3 WCzone3 190 plf .. = C7 w O} O ° . . . : Worst Case Downward WCdown 74 . pit . w � _.En z p • Worst:Case Seismic Demand WCe q ... ..15 ' If p g.. rH Worst Case Shear for Uplift Cases WCshear up 4.8 plf. w Worst Case Shear for Downward Cases WCshear, down.14 plf M . m t Worst Case Shear for Seismic Cases: i WCshear eq 14 pif �- Roof Wind Zone Dimensions_ `,r,° Width, of:edge and corner Tones a. 5 ft :. . Ln, Maximum Allowable Spacing of Maximum, allowable attachment spacing, Lallowed_zonel. 72. in m Maximum allowable attachment spacing, Lallowed_zone2 -36 in m ._ Maximum allowable•attachment spacing, . Lallowed_zone3 30 in ILO E Maximum allowable cantilever, zone 1 CantileVerzonel 36 in o Maximum allowable cantilever, zone 2 Cantileyerzone2 .18 in y Maximum allowable cantilever,, zone 3 Cantileverzone3; 15 In Rail Bending Rail Bending Up Strength. Mn_rail_up 548 Ib -ft Rail Bending Down Strength: Mn rail down 580 Ib -ft L -Foot L -Foot Tension Strength : Tn_L-Foot 510 Ib t u �~UPEO L -Foot Com ression Strength On 999 Ib' P g d 1 Building Depprt l L -Foot Shear Strength Vn_L-Foot 195 Ib.'; � ` �R11 4' APR Z '2016 RENEWED FOR f;::`�E CO"PLIAINCE Revio- Wed By: == FIGURE B:. INVISIMOUNT S TRUCTURAL CALCULATION FIGURE. C: LAG BOLT STRUCTURAL CALCULATION OPPORTUNITY SPRI- Fremont PROJECT D-0051671 DATE DRAWN 04-20-2016 DRAWN BY HLLUVIOSO DATE CHECKED 04-20-2016' CHECKED BY APATEL. . SHEET ' .. SOLAR -S3 � a in W w O o 01 N N O Oi U) ¢ 01 co im 0. �, at Z U w0. SSE Vic„ - - g3 O U gds -®k _ I 1 August 2014 U _.Q X08 A F F. E' SunPower Invisimount Design Tool A F F EVStructural Calculations U a U -- STRUCTURAL ENGINEERING STRUCTURAL ENGINEERING Page 11 August 2014 • Performed independent calculations for six example project sites, plus spot checks of other potential project conditions, to compare to the structural design loads and load, combinations Guillaume Carre calculated by the tool to act on the arrays, rails, and attachments to the roof structure. For all SunPower Corporation of the examples that we checked, the loads and load combinations calculated by the tool .are 1,414 Harbour Way South consistent -with our independent calculations in accordance with the structural design Richmond; CA 94804 standard ASCE 7-10 Minimum Design Loads for Buildings and Other Structures. • Performed independent calculations for ten example project sites, plus spot checks of other Invisimount Desi n Tool. Subject: Sung, potential project conditions, ns, to compare to the bill of materials estimated by the tool. For all Structural Calculations of the examples that we checked, the quantities of parts'estimated by,the tool are the same as the quantities . from our independent calculations'. or within a reasonable tolerance. The Dear Guillaume, attached "Engineering Basis of Calculations" describes the procedure that the tool uses for estimating the bill of materials. w Per your request; we are pleased, to present the findings from our review and testing of. Ln. z SunPower'.§Invisimount Design Tool, an online tool that: SUMMARY OF FINDINGS . ® Evaluates structural design loads on SunPower Invisimount solar arrays ' To an extent consistent with the : scope: of our review, , our professional opinion is that the U < pLn Q U • Evaluates the maximum allowable spacing of attachments of the system to the roof to. resist Invisimount Design. Tool calculates. structural design loads on the solar arrays, and maximum Q ij w z U design loads allowable spacing. of attachments. to the roof structure- that are consistent with the standards and r, o . N a •. Estimates the bill of materials for specific projects to assist with ordering arts from P P J g P procedures :described in the attached "Engineering Basis of Calculations" including ASCE 7=10 g g g.. Q o V) o as SunPower Minimum Design Loads for Buildings and Other Structures, the 2012 International Building ¢ a 0 < LU < Code, and the 2013 California Building Code. (D Lu 0 o a o SCOPE OF THE TOOL Ln ? : `n Z Invisimount by SunPower is..a solar panel support system for.installing solar photovoltaicarrays DESIGN RESPONSIBILITY w O on sloped roofs of buildings: Typically such buildings are residential with shingle or tile roofs. The Invisimount.Design Tool is 'intended to be used under the responsible: charge of a registered � D Each row or column of modules is .supported by two rails, which are attached to the roof design professional) where required by the authority having, jurisdiction. In all cases, the tool z structure. The numberr and spacing of attachments to the roof structure can vary .depending on, should be used under, the direction of a design professional with sufficient structural engineering Ln for example, structural loads at a particular site, the type of attachment hardware used, and. knowledge and experience to be able to: spacing of the building rafters: • Evaluate whether. the. tool .is applicable to the project, based' on the "Engineering Basis of U V The .attachedEn ineering Basis of Calculations describes the scope of the Invisimount Design g „ Calculations document and the characteristics of the project, and Tool, its calculation procedures, and assumptions. for use. • Understand and determine the .appropriate values for all input parameters of the tool. o - SCOPE. OF OUR REVIEW Results of the tool should be checked against the design professional's judgment. Excerpts from . z standards such as ASCE 7-10 are presented in the tool as pointers to the standard and are not o = Maffei Structural Engineering collaborated .with SunPowef on the development of the . intended to diminish the user's responsibility to consult the applicable figures and sections of the LO Invisimount Design Tool, including the following tasks related to structural calculations:standard directly. The user or design professional in responsible charge assumes full design w o Provided documents describing applicable building code formulas and 'the calculation responsibility. °` u procedure to be implemented by SunPower'§ programming team The tool does not check the capacity of the building structure to sort the loads imposed on the o • Worked with SunPower and. the programming team during implementation to answer Worked buildingb the,arra , such .as bendin strength of roof ra "i an lin betweeAiiA 2s� , AD Y Y g g. g p "its- related to structural calculations and test the functionalit of the tool y'�� 6 Pailoirtg Danwrtjerti I? OPPORTUNITY SPRI- Fremont PROJECT D-0 051671 _ 415.329.6100 The terms registered. design professio�zal and registered design ar defined in Ti x° i' gd "+� www.maffei-structure.corn (; the 2012 IBC Section 202. _. 148 Hennnosa Avenue �) Oakland, CA 94618 REVIEWED FOR � �"�� C01rAPLIA CE DATE DRAWN 04-20-2016 DRAWN BY HLLUVIOSO By: Revitnwed - DATE CHECKED 04-20-2016 - - CHECKED BY APATEL FIGURE D: STRUCTURAL SUMMARY -PAGE 1 FIGURE E: STRUCTURAL SUMMARY PAGE 2 SHEET .. S®LAR-S4 N F - �$ � Ln IU w F 0 o 01 F . . W W c a >- ( T � a O 00 � "... , J „rd X y- A �.'i�: �•-� X • .i�2$1Cn :3r. ..tY Y. v'"t' p,:'a`'.tw4' y ..}v e"7Y. " �.,P ➢�'. �. A° $ y�.,�,.;±<,'Xvi :�. 5, �. N,t E�K f:�� �� 3i �� Yk'f. `rli•: f'�� 1 iii V, SF J 4Sa_ — X44 ! �b� . � y y -.`E •� _ � i. ...�r �` -L_. i �Z'aty r .;:tf:'' f- ' �•'' i' th : c -K'R'N �'�'z�`.-F1fi3'""^ `�2 d`iw '!,3 p'C@- "�r947 ryv.-i' "hr `-£,°.lr'• a`Y •µ+F-:-6'�^- _'r �;.. - b. :'t U U O V In .. .'.'. ♦ iJ r �] L 4 l �! t .2 {. ` ,7",� J-;. 3`bf .$ {4�. `11�.~Wr7n•'6 /� .4 L..' _ J: i r' I— 0 Z m In "'� W k. 00 11 August 2014 4 j4 C d� o a U SunPower Invisimount Design Tool Y c hyo M A F F E I Structural Calculations - STRUCTURAL ENGINEERING. Page 3 '�L'aZf rt io ®`OLTAL01-9 IM Is nirem in 0 • requires additional knowledge of the building and is outside the .scope of the design. tool and our . review. InvisWrountO®� -magesnti If you have any questions regarding these findings, please call me at 510-604.-2688. . Sincerely Y, �_.,,,` Module* /Mid Clamp and Rail Module* /;End Clamp and Rail Maffei Structural Engineering Joe Maffei; S.E., Ph. D, LEED AP Principal Cxpires3 s T 1t.ICTL oe@maffei-structure.com 4' — r W O Midi M d Clamp End Clamp Rail & Rail Splice Ground Lug Assembly End Cap U 0 U .. .. - .r � _ rn n O - LU1 H Ot z O N m ILL. V d to . PE O Q.a a fn Da ¢ O w o Q = O.0 Q " W Lu z . unt Operating ConditionsO z Temperature. 40° C.to 90° C (-40° F to 194° F) Component Material Weight Ur a' 2400 Pa uplift Max: Load Pa U AISl5400 downforce Mid Clam Black oxide stainless steel A SI 304 _ 63,g 2.2 oz) P i Clamp Black anodized aluminum alloy 6063-T6 110 g (3.88 oz)z m Rail Black anodized aluminum alloy, 600546 830 g/m (9 oz/ftj • Certifications Ln Rail Splice Aluminum alloy 6005-T5 830 g/m (9 ozift) Warraties 25 -year product warranty 5 year finish warranty Ground Lug 304 stainless m - = 106.5 g/m (3.75 oz). Assembly (A2-70 bolt; tin -plat ed copper lug) U m _ End Cap . Black acetal (POM) copolymer 10.4 g (0.37 oz) UL 2703. Listed L Certifications Class A fire rating when distance between o Roo • o e - e e roof surface and bottom of SunPower _ - o • module frame is <_ 3.T' z O Composition shingle Rafter Attachment. m Application Composition Shingle Roof Decking Attachment RobfAttathmentHardware Curved and Flat Tile Roof Attachment - Universal Interface for Other Roof Attachments Refer ao(atf 3Sft> -'ant herdware man fa i��'t is eel jhi� J Z.4 BL ding D-Pert4ent *Module frame that is compatible with the InvisllAount system required for hardware intern erablitY. . IEV!CD FOR_ODE CONIPLIANCE OPPORTUNITY SPRI- Fremont . .R` - (D 2015 SunPower Corporation: All Rights Reserved. SUNPOWER, the SUNPOWER logo, and, INVISIMOUNT are trademarks or registered n�OweGC m PROJECT D-0031671 trademarks of SunPower Corporation.All other trademarks are the'property"of their respective owners. -. ,,1 Specification's datasheet are subject to change without notice; { 5f'�l(W�(j ji.D¢bmeny� B _ included in this DATE.DRAWN 04-20-2016. DRAWN BY' - HLLUVIOSO - SUN• O • DATE CHECKED 04-20-2016 CHECKED BY APATEL .. .. FIGURE F: STRUCTURAL SUMMARY -PAGE 3 .. FIGURE G: INVISIMOUNT DATA SHEET SHEET .. SO Li4R-S5 .. r'r1U 1 U.VUL 1 HIV IVIUUULCJ HIVU r M11MLO USL - InvisiMount Mounting and Bonding.Systemsfof use with - - Photovoltaic Modules,' consisting; of the following components., L • F oot, Rail; Rail Splice, Mid Clamp,. Ground Lug Assembly. These system components have also been evaluated fora .Class A System Fire Classification fora steeploped roof.with.Type 2 modules. (See addendum page for additional information.) CaY. No.' . Investigated for Bonding. Investigated :for . Mechanical _ Loading:. System :Fire Classification (A, B or C) Tested in . Combination With Photovoltaic mounting system InvisiMount.- consisting Y Y A' Listed PV Modules: of the following . ' } U0 Sunpower Corp:. Models SPR-xYY-###; where YY . components:L-Foot, a to represents numbers 18, 19,: 209.r 21, and ### Rail; Rail Splice, Mid OD o o Z Q < Q. 2 LU represents any number. from 365'to 310 and 274 Clamp,:Ground. Lug. .. (31rn, �,a N 1 N w aH IL U)q W. to 233; SPR-EYY-###, where YY represents Assembly. .Q T w � numbers 18, 19; 20 or 21, and #,## represents ' 01z U o any. number. from 345 to 285 and 250• to 225. All N 'gcH O .. �' O models identified must have the Gen•5 frame and. .N Z Egg . yO5� ; ro'E +i' In have Type 2 module characterization: Z a 0 OPPORTUNITY SPRI- Fremont PROIECr D-0051671 DATE DRAWN' 04-20-2016. PRAWN BY - HLLLWIOSO DATE CHECKED 04-20-2016 CHECKED BY APATEL. SHEET - SOLAR - S6 U? Last Updated on, 2014-09-26 Standard s. indicated on this Certificate � w V In £ ' } U0 When the UL Leaf .Mark is.on the product, or when the•word. "Environment" is Included -in the Mark; please search the UL Environment database for additional information regarding this product's certification: a to U), Go v L OD o o Z Q < Q. 2 LU > > (31rn, �,a N 1 N w aH IL U)q W. .tn .Q T w � '0, 01z U o W N 'gcH O .. �' O .O N .N Z Egg . yO5� ; ro'E +i' In The .UL Listing Mark generally includes. the following elements: the symbol UL in a circle: with the .Z .-. o W �E ti.. Q O . . name. (productidentifier) as indicated in the appropriate UL Directory.. O =' X: v: Look for the UL Listing Mark. on the' product. F U REVIEWED FOR CCDE COMPLIANCE <r / wlllam R. Camey, Director, Nodh Amorlean CortifieaUon'PTerems - .. .. ReviAwed By: - _ UL LLC :V O •� • ,Any Information and doc imentatlon Involving UL Mark cervlees aro provided on behalf of UL LLC (U L) or any authorized licensee of UL For questions, please contact a local UL Customer Service Representative at U U nthttpJ/database:um/cgi-bin/CYV/template/LSEXT/1FRAMFshowpage.html7name-QIMSE4669818ccnshortbte=Moung+Systems+Mounting+Devices+ 1/1' FIGURE H:. CERTIFICATE OF COMPLIANCE FIGURE.I:.CLASS AFIRE RATING UL LISTING Z a 0 OPPORTUNITY SPRI- Fremont PROIECr D-0051671 DATE DRAWN' 04-20-2016. PRAWN BY - HLLLWIOSO DATE CHECKED 04-20-2016 CHECKED BY APATEL. SHEET - SOLAR - S6 Have been investigated by. -UL. - in accordance: with the. Last Updated on, 2014-09-26 Standard s. indicated on this Certificate � w Standard S. f or Safety: UL Subject 2703, The.Outline of Investigation for Mounting V) O ' } U0 When the UL Leaf .Mark is.on the product, or when the•word. "Environment" is Included -in the Mark; please search the UL Environment database for additional information regarding this product's certification: a U n o U Z Q < Q. 2 LU J _ C) H 0 a 0 w " U. w Q 2 V)Z x a 0 Ln �' z c Ow ¢ U 0 �,a N 1 N w aH IL U)q u w O� In .0 Q •. Q P. M '0, U U . the following format: "©. 2015 UL LLC": Listing and Follow. -Up Service �� ; ro'E +i' In The .UL Listing Mark generally includes. the following elements: the symbol UL in a circle: with the z ti.. In . . . Z a 0 OPPORTUNITY SPRI- Fremont PROIECr D-0051671 DATE DRAWN' 04-20-2016. PRAWN BY - HLLLWIOSO DATE CHECKED 04-20-2016 CHECKED BY APATEL. SHEET - SOLAR - S6 Have been investigated by. -UL. - in accordance: with the. Last Updated on, 2014-09-26 Standard s. indicated on this Certificate „ Questions . Print this papa Terms'of'Use Page Too. Standard S. f or Safety: UL Subject 2703, The.Outline of Investigation for Mounting ©'2015 UL' LLC ' Sy stems, Mountin Devices, am in /Retentii y g Clp g on Devces, 'and When the UL Leaf .Mark is.on the product, or when the•word. "Environment" is Included -in the Mark; please search the UL Environment database for additional information regarding this product's certification: G round Lugs for:use with.Flat Plate Photovoltaic Modules and The appeararice.of a company's name or. product in this database.does.not. in itself. assure that products.so Identified, have been manufactured. n Panels . under.UL's.Follow'-Up-Service.'only:those products bearing the UL.Mark should be considered to be:Certified and covered under UL's Follow=Up Additional Information: See the UL Online Certifications Directory at t Service. Always look for the.MarK on he product . - WWW:ULG0111/database for additional InfOrmatiOn UL permits the reproduction of the material contained in the Online .Certification Directory subject to the following conditions: 1. The Guide: Information; Assemblies, Constructions, Designs, 'Systems, and/or.Certifications.(files) must be presented in their entiretyand in.a non misleading manner, without any manipulation of the data (or drawings), 2: The, statement "Reprinted from the online. Certifications Directory en n ition, the reprinted material must include'a copyright notice in with permission from " must appear adjacent to the extracted mat 'al:' I add i UL . Only those products bearing the UL Listing Mark should be considered as being covered by UL's . . the following format: "©. 2015 UL LLC": Listing and Follow. -Up Service �� ; ro'E +i' The .UL Listing Mark generally includes. the following elements: the symbol UL in a circle: with the C;Uildirtg �u � �� rtment: t- ti.. word a control number (may: be alphanumeric) assigned by UL;.and the product category : •; 'LISTED"; f name. (productidentifier) as indicated in the appropriate UL Directory.. -� r .' AM: 2�2011 v: Look for the UL Listing Mark. on the' product. F REVIEWED FOR CCDE COMPLIANCE <r / wlllam R. Camey, Director, Nodh Amorlean CortifieaUon'PTerems - .. .. ReviAwed By: - _ UL LLC ;r. u • ,Any Information and doc imentatlon Involving UL Mark cervlees aro provided on behalf of UL LLC (U L) or any authorized licensee of UL For questions, please contact a local UL Customer Service Representative at Page 1 oft nthttpJ/database:um/cgi-bin/CYV/template/LSEXT/1FRAMFshowpage.html7name-QIMSE4669818ccnshortbte=Moung+Systems+Mounting+Devices+ 1/1' FIGURE H:. CERTIFICATE OF COMPLIANCE FIGURE.I:.CLASS AFIRE RATING UL LISTING Z a 0 OPPORTUNITY SPRI- Fremont PROIECr D-0051671 DATE DRAWN' 04-20-2016. PRAWN BY - HLLLWIOSO DATE CHECKED 04-20-2016 CHECKED BY APATEL. SHEET - SOLAR - S6 FIGURE A: SINGLE LINE DIAGRAM - NO STRINGS COMBINED PRIOR TO INVERTER: 5.56 kWDC INCOMING SOURCE FEED TOP -FED *MSP MAX PV BREAKER (A) _ (N) MAIN SERVICE PANEL [ 125 A x 120% ] - 100 A 125A MIN., 120/240V,APH, 3W SUNPOWER MODULES = 50 A LOCATION: SW CORNER OF HOUSE SPR -E20-327 MCB ROOFTOP 100A, 2P A B C (E) UTILITY ARRAY WIRING SB5000TL-US-22(Sunny Boy) -240 VAC rte.. BIDIRECTIONAL METER 6 INVERTER EFFICIENCY 97.00% METER NO.: RATED MAX OUTPUT1006701507 CURRENT 22.004 MPPT 1: STRING 1 5 MODULES/STRING i —� I—}\—H TO EXISTING OPPORTUNITY SPRI- Fremont PROJECT D-0051671 DATE DRAWN 04-20-2016 DRAWN BY HLLUVIOSO DATE CHECKED 04-20-2016 CHECKED BY APATEL SCALE NOT TO SCALE SHEET SOLAR -E1 ~ f TAG DESCRIPTION W LU o 0 CONDUCTOR /. CONDUIT SCHEDULE ELECTRICAL NOTES. Ln > FILIRE$1 J IONITORING YSE �)� .>- V) phi Q '^ c]) 00 oo 0 SOLAR' PV'MODULE / STRING Z TAG DESCRIPTION & CONDUCTOR TYPE " CONDUCTOR SIZE NUMBER OF CONDUCTORS B CONDUIT/CA LE TYPE CONDUIT CO IT SIZE W z p 0 T� DC7 DC"CONVERTERS' N0 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED .TO GROUND AT COUPLINGS ON BOTH ENDS.,��-^Nz o a " .� / � g Department SOURCE CIRCUIT JUNCTION. BOX YE5 Q 2 PV -WIRE 410 'AWG 6 m z Q U . . z A Ln O Ayl 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND.,_ i MAIM SERVitESP}1IL r r q p rp ng ca GL� ® SEPARATE DC DISCONNECT NO EGC:'BARE"COPPER #10 AWG 1 = 2 THWN-2 3: © INTERNAL INVERTER DC DISCONNECT YES €�N #10 AWG 6 EMFROM T 3/4" R TOP OF ELECTRICAL OUNDUIT SHALL NOT TDOOR LOCATIONS OCATIONS WITHOUT U .i STRING INVERTER YE5 EGC: THWN-2 410 AWG 1 Ln IT SP CIFICAPPROVALF OMSUNPOWER.I SITE-SPECIFIC F GRANTED C99AA C tt�� R`1"IGVbEL FOR larC CUMPLIANCE e SOLAR LOAD CENTER N0. © THWN-2 #10 AWG 3 EMT 3/4" APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3 INSULATED BONDING BUSHINGS TO BE USED ON ALL CONDUIT TERMINATIONS REGARDLESS OF VOLTAGE. THE HALL INSULATING FITTINGS S BE SUITABLE FOR BONDING TO GROUND IN ACCORDANCE WITH NEC 250.92. INSULATED BOX ev' 'v /@ 15A, 1P ISA, 1P �1 �1 ®. PV P METER, NO EGC; THWN-2 #10 AWG 1 0' RATE AC. g SEPARATE AC•DISCONNECT NO D❑ THWN-2 #14 AWG 4 EMT .. 1/2" CHECK BOX FOR WHETHER SYSTEM IS GROUNDED OR EGC:"THWN-2 #14 AWG . 1 UNGROUNDED: CONNECTORS DO NOT MEET THIS REQUIREMENT. p GROUNDED (INCLUDE GEC) 4. PROPER LISTING EXPECTED FOR CONDITIONS OF USE,ON ALL 2' UNGROUNDED LUGS,.FTTTINGS, CRIMPS, ETC. PV SUPERVISOR FOR UNGROUNDED SYSTEMS: 5. ALL CONDUIT BEND RADII TO CONFORM TO THE NEC • DC OCPD DISCONNECT BOTH CONDUCTORS OF EACH MINIMUM BEND RADII REQUIREMENTS. SOURCE CIRCUIT. 6. MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR 1/2' EMT • UNGROUNDED CONDUCTORS MUST BE IDENTIFIED PER ALL NEW EQUIPMENTS TO BE INSTALLED. 7. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC CAT5e 2) #14 THWN-2 210.5(C). WHITE FINISHED CONDUCTORS ARE NOT AND LOCAL UTILITY REQUIREMENTS. ETHERNET (1) #14 THWN72 EGC CONNECTION TO PERMITTED. B. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. GFCI DSL/CABLE MODEM 9. ELECTRICAL METALLIC CONDUIT (EMT) SHALL BE, USED FOR 1/2" EMT_ ALL EXTERNAL CONDUIT INSTALLATION.. (2) #14 THWN-2. (1) #14 THWN-2 EGC FROM INVERTER DATA COMMUNICATION CABLE . OPPORTUNITY SPRI- Fremont PROJECT D-0051671 DATE DRAWN 04-20-2016 DRAWN BY HLLUVIOSO DATE CHECKED 04-20-2016 CHECKED BY APATEL SCALE NOT TO SCALE SHEET SOLAR -E1 ~ f W LU o 0 o,. `s U) Ln > 0 � � .>- V) phi Q '^ c]) 00 oo 68 Z '--iU 3 U ac p p .. p W z p 0 z z0. M J f- z .� O a o a " LnZ �� Q 2 w 0. m z Q U z a Ln O Ayl rn �. U' MCK O = 2 U 3: ULU €�N 0 a U ktlGG€i'o U .i Ln OPPORTUNITY SPRI- Fremont PROJECT D-0051671 DATE DRAWN 04-20-2016 DRAWN BY HLLUVIOSO DATE CHECKED 04-20-2016 CHECKED BY APATEL SCALE NOT TO SCALE SHEET SOLAR -E1 W U) 't U O Ln ( Q Z '--iU Q p p .. p W z p 0 z z0. M J f- z .� O a _._ U) Y ,-., J i Q O W J U IV .(D LL- Q 2 w 0. a Q U z" ria .. U C7 W Ln O V) In a rn �. u aS' U U 3: ULU w Ln Ln OPPORTUNITY SPRI- Fremont PROJECT D-0051671 DATE DRAWN 04-20-2016 DRAWN BY HLLUVIOSO DATE CHECKED 04-20-2016 CHECKED BY APATEL SCALE NOT TO SCALE SHEET SOLAR -E1 DC, MPPT 1 MAXIMUM.SYSTEM VOLTAGE (DC) 346.58 V LOWEST AMBIENT. TEMPERATURE FOR SITE 0"C PV MODULE OPEN CIRCUIT VOLTAGE 64.9 V PV MODULE VOC TEMPERATURE CORRECTION COEFFICIENT -176.6 mVPC PV MODULES PER STRING 5 VMAX = (VOC + (VOC_COEFF / 1000) x (TMIN-25)) x MODULES_STRING 346.58 V MAXIMUM SYSTEM CURRENT (DC) 8.08 A PV MODULE SHORT CIRCUIT CURRENT 6.46 A MULTIPLIER, HIGH IRRADIANCE (1250W/m2) FOR > 3h 1.25 IMAX DC = ISC x 1.25 8.08 A ROOFTOP ARRAY WIRING (DC) #10 MINIMUM WIRE AMPACITY: ]WIRE MIN = IMAX DC x 1.25 10.09.A CONDUCTOR DE -RATING 30 A (>27.50 A) MAXIMUM AMBIENT TEMPERATURE 54°C TEMPERATURE DE -RATING COEFFICIENT 0.76 CURRENT CARRYING CONDUCTORS/CONDUIT 1 - 3 CONDUIT FILL DE -RATING COEFFICIENT 1 CONDUCTOR AMPACITY - CONDITION OF USE _' 30.4 A (>8.08 A) WIRE AMPACITY SELECTED X TEMP COEFF. X FILL COEFF. Z CONDUCTOR AMPACITY -TERMINAL TEMP LIMIT 35 A (>10.09 A)" ROOF PENETRATION TO INVERTER WIRING (DC) 410 MINIMUM WIRE AMPACITY: (WIRE MIN = IMAX DC x 1.25 10.09 A CONDUCTOR DE -RATING ¢ MAXIMUM AMBIENT TEMPERATURE 61"C TEMPERATURE DE -RATING COEFFICIENT 0.58 CURRENT CARRYING CONDUCTORS/CONDUIT 4-6 CONDUIT FILL DE -RATING COEFFICIENT 0.8 CONDUCTOR AMPACITY - CONDITION OF USE = 18.56 A (>8.08 A) WIRE AMPACITY SELECTED X TEMP COEFF. "X FILL COEFF.. D-0051671 CONDUCTOR AMPACITY -TERMINAL TEMP LIMIT 35 A (>10.09 A) CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 VOLTAGE DROP AT 100 FT CONDUCTOR DISTANCE 0.54./o ELECTRICAL CALCULATIONS DC, MPPT 2 MAXIMUM SYSTEM VOLTAGE (DC) 485.21 V LOWEST AMBIENT TEMPERATURE FOR SITE 0'C PV MODULE OPEN CIRCUIT VOLTAGE 64.9 V PV MODULE VOC TEMPERATURE CORRECTION COEFFICIENT -176.6 mV/`C PV MODULES PER STRING 7 VMAX = (VOC + (VOC-COEFF / 1000) x (TMIN-25)) x MODULES -STRING. 485.21 V MAXIMUM SYSTEM CURRENT.(DC) 8.08 A PV MODULE SHORT CIRCUIT CURRENT 6.46 A MULTIPLIER, HIGH IRRADIANCE (1250W/m2) FOR > 3h 1.25 IMAX DC = ISC x 1.25 8.08 A ROOFTOP ARRAY WIRING, (DC) #10 MINIMUM WIRE AMPACITY: IWIRE MIN = IMAX DC x 1.25 10.09 A CONDUCTOR DE -RATING " 30 A (>27.50 A) MAXIMUM AMBIENT TEMPERATURE 54"C TEMPERATURE DE -RATING COEFFICIENT 0.76 CURRENT CARRYING CONDUCTORS/CONDUIT 1 - 3 CONDUIT FILL DE -RATING COEFFICIENT 1' CONDUCTOR AMPACITY - CONDITION OF USE = 30.4 A (>8.08 A) WIRE AMPACITY SELECTED X TEMP COEFF. X FILL COEFF. Z CONDUCTOR AMPACITY - TERMINAL TEMP LIMIT 35 A (>10.09 A) ROOF PENETRATION TO INVERTER WIRING (DC) #10 MINIMUM WIRE AMPACITY: ]WIRE _MIN = IMAX_DC x 1.25 10.09 A CONDUCTOR DE -RATING ¢ MAXIMUM AMBIENT TEMPERATURE 61°C TEMPERATURE DE -RATING COEFFICIENT 0.58 CURRENT CARRYING CONDUCTORS/CONDUIT 4-6 CONDUIT FILL DE -RATING COEFFICIENT 0.8 CONDUCTOR AMPACITY - CONDITION OF USE = 18.56 A (>8.08 A) WIRE AMPACITY SELECTED X TEMP COEFF. X FILL COEFF. D-0051671 CONDUCTOR AMPACITY - TERMINAL TEMP LIMIT 35 A (>10.09 A) CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 VOLTAGE DROP AT 100 FT CONDUCTOR DISTANCE 0.39 AC INVERTER TO GRID -TIE WIRING (AC) 4110 INVERTER RATED POWER 5000 W INVERTER/ GRID VOLTAGE 240 V INVERTER RATED MAX OUTPUT CURRENT: IAC_OUT 22.00 A MINIMUM WIRE AMPACITY: IMAX = IAC OUT x 1.25 27.50 A CONDUCTOR DE -RATING O o MAXIMUM AMBIENT TEMPERATURE 36°C TEMPERATURE DE -RATING COEFFICIENT" 0.91 CURRENT CARRYING CONDUCTORS/CONDUIT 1-3 CONDUIT FILL DE -RATING COEFFICIENT 1 CONDUCTOR AMPACITY - CONDITION OF USE _ 27.3 A (>22.00 A) WIRE AMPACITY SELECTED X TEMP COEFF. X FILL COEFF. CONDUCTOR AMPACITY - TERMINAL TEMP LIMIT 30 A (>27.50 A) CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 VOLTAGE DROP AT 50 FT CONDUCTOR DISTANCE 0.71 OVERCURRENT PROTECTION (AC) 30A, 2P MINIMUM OCPD = IAC x 1.25 27.50 A NEXT LARGER OCPD SIZE 30 A 1I L ori, RE�'IE 'EO ; G0�4}PI_IANCE R.eviawed By ,.��~ �`7�`�t 1I to L L w >_to O o rns v o U >- Ln > a, ¢ 01 'n wo m 3 ¢ V � eN Z u a w 'gcN 6L Qi r-)0 Z Q [) Z F rl N LU H m Z . w a 8 Z ¢ v =98 . � O Q � = _ OPPORTUNITY SPRI- Fremont a u. D-0051671 �- Ln DRAWN :BY Q HLLUVIOS0 DATE CHECKED O. -i d u APATEL V i u V SHEET .. . to o W > U W V Ln U O U p Lr) V) . O Qi r-)0 Z Q O a C7. Y 0� O 43) LL6 U W rl N LU J Q J U U J w . U ilu -, OPPORTUNITY SPRI- Fremont PROJECT D-0051671 DATE DRAWN Ln DRAWN :BY HLLUVIOS0 DATE CHECKED 04-20-2016' Ln APATEL SCALE to o > U W V � w O ilu OPPORTUNITY SPRI- Fremont PROJECT D-0051671 DATE DRAWN 04-20-2016 DRAWN :BY HLLUVIOS0 DATE CHECKED 04-20-2016' CHECKED BY APATEL SCALE NA SHEET .. . SOLAR -E2. 0 d s N OPPORTUNITY SPRI-.Fremont PROJECT D-0051671 DATE DRAWN, 04-20-2016_ - DRAWN BY HLLUVIOSO" DATE CHECKED 04-20-2016 - CHECKED BY APATEL- SCALE NOT TO SCALE SHEET .. .. .. SOLAR -E3 Ln I LABELING SPECIFICATIONS . � WARNING: -6" Ln W WARNING: MDUAL POWER SOURCES. SECOND" O " C" - F INVERTER OUTPUT CONNECTION; SOURCE IS PHOTOVOLTAIC SYSTEM. " N }M - co O. DO NOT RELOCATE THIS - RATED AC OUTPUT CURRENT: - (j) Q Ln OVERCURRENT DEVICE 22.00 A �b U) AC NORMAL OPERATING - U VOLTAGE: 240V o. U) Q � Z Q = 0 Lu O F- CLO w U0 Lu = Y ,r 0) CAUTION N M N LU Z O F U H W a cn Z . ,•.•,, m WARNING -0 I,LQ N G IS POWER iPHOTOVOLTAIC U Dc DISCONNECT ELECrRICSIHOCK HAZARD ALSO SUPP LI ED, FROMTHE mZ THIE DC CONDUCTORS OF THIS . a. < ' • • • WARNING: ELECTRIC SHOCK FOLLOWING DISCONNECTS Ln HAZARD. IF A GROUND FAULT IS ' • • • INDICATED NORMALLY GROUNDED LGICATEDAS WARNIRG ANUMAY • CONDUCTORS MAYBE jHOWN: - WARNING: ELECTRIC SHOCK UNGROUNDED AND ENERGIZED " O ~ HAZABD U HAZARD. THE DC CONDUCTORS • • TOUCH e ' SIGNAGE LOCATIONS: OF THIS PHOTOVOLTAIC INTEGRATED SYSTE M' SYS ARE UNGROUND D AND !=3DC DISCONNECT HN • " ' _ " "INVERTER - - TERMINALS ON e D _ • INVERTER INTEGRATED DC DISCONNECT MAY BE ENERGIZED. INVERTER RATED MAX POWER -POINT CURRENT: 11.96 ADC. r__ ____________ _ • D / P XPOINT RATED MTAGA4 VDC I' ®® I . r - S ° _ SHORT CIRCUIT CURRENT: 16.15 A' . - MAX SYSTEM VOLTAGE: 485 VDC _I I II LU_ e tAAXIMIJMI POWER -POINT1 1.96 ADC WARNING: • 404 VDC. PHOTOVOLTAIC.POWER SOURCE . /r Y • 485 VDC. .. o' 16.15A 0 ___--- _-___ ____ J SIGNAGE LOCATIONS: " - SERVICE POINT & 17 PANEL UTILITY METERING PHOTOVOLTAIC SYSTEM _ _ • INVERTER INTEGRATED DC DISCONNECT - - - - JBOX . .. - REFERENCES: ALL REQUIREMENTS ARE MET BY: - **2013 CALIFORNIA ELECTRICAL CODE**' SIGNAGE NOTES 1. MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE, WEATHER RESISTANT AND _ SUITABLE FOR THE ENVIRONMENT. " - 2. ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITH MINIMUM 3/" LETTER HEIGHT,, - - WHITE ON RED BACKGROUND. 3. MAIN SERVICE DISCONNECT MARKING SHALL BE PLACED ADJACENT TO MAIN SERVICE " - DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM THE LOCATION WHERE THE LEVER . . • oTOvoLTA IS OPERATED.. C - - DISCONNECTTURN 4. .MARKING IS. REQUIRED ON, ALL INTERIOR AND EXTERIOR. DC CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES; AND JUNCTION BOXES TO ALERT THE FIRE SERVICE • •• ' ® - ®SO -LAR .. TO AVOID CUTTING THEM. MARKINGS SHALL BE PLACED EVERY 10', AT TURNS AND • ' ! ABOVE AND/OR BELOW PENETRATIONS, AND AT ALL DC COMBINER AND JUNCTION MAIWSERVICEPANEL,BOXES.. o • .22.00 A . SIGNAGE LOCATIONS: o o' • • • 240 VAC 5. DO NOT USE SCREWS FOR SIGNAGE ATTACHMENT. USE ONLY APPROVED ADHESIVE. MAIN SERVICE PANEL SIGNAGE LOCATIONS: SIGNAGE LOCATIONS: e MAIN SERVICE PANEL • MAIN SERVICE PANEL f p LE 6tl _UCCU!RRjENT' WARNING IN V HTE 6 CONNECTION DO NOT RELOCATE APR 2 �DC CURRENT THIS:OVERCUA• "YLP"Op MAYAN • • � �• Df CURRENT RATED Ac 22.00A RE—VIEW—ED FOR '-C' 1C 0,01`!if LI!'lNCE • OPERATING AC VOLTA�GE-,240 VAC ReVidW@d By; DC CURRENT SIGNAGE LOCATIONS: SIGNAGE LOCATIONS: ° ADJACENT TO PV BREAKER • DC CONDUIT REFER TO NOTE # 4 0 d s N OPPORTUNITY SPRI-.Fremont PROJECT D-0051671 DATE DRAWN, 04-20-2016_ - DRAWN BY HLLUVIOSO" DATE CHECKED 04-20-2016 - CHECKED BY APATEL- SCALE NOT TO SCALE SHEET .. .. .. SOLAR -E3 Ln I . � Ln W D O C" F U) N }M co 0 V co O. �gFg �5K (j) Q Ln co co �b U) � U o. U) Q � Z Q = 0 Lu O F- CLO w U0 Lu = Y ,r 0) rn. O J ¢ U p' . . ZLu W N M N LU Z O F U H W a cn Z . ,•.•,, m A U U� Y mZ Lu a. < 0 Ln O' _ _ 608 O ~ U HN 0 d s N OPPORTUNITY SPRI-.Fremont PROJECT D-0051671 DATE DRAWN, 04-20-2016_ - DRAWN BY HLLUVIOSO" DATE CHECKED 04-20-2016 - CHECKED BY APATEL- SCALE NOT TO SCALE SHEET .. .. .. SOLAR -E3 W U) U) � U o. U) Q � Z Q = 0 Lu O F- CLO w U0 Lu = Y ,r 0) rn. O J ¢ U p' . . ZLu W N M N LU Z O F U H W a cn Z . ,•.•,, m U Y Ln In 0 d s N OPPORTUNITY SPRI-.Fremont PROJECT D-0051671 DATE DRAWN, 04-20-2016_ - DRAWN BY HLLUVIOSO" DATE CHECKED 04-20-2016 - CHECKED BY APATEL- SCALE NOT TO SCALE SHEET .. .. .. SOLAR -E3 tief V) i- V's • .. Lu. m nLri Ln o o o rn o. to < o m 3 < U z3N . ,......... ..... _; .............. ................... :...._...__...__.. r�dencurrSUNY BY 50T1-US-22 2tOVoci-----•=--�---•---•ACCSSOfIeS . 0 < of o _o Ln Z Fe PENTAIR TYPE 3TPFR EOKFiI(fdf.fR--------- I < 2:v n .... _ ........... qy ...... ..n ..... Psess.�m4a SCREW-OVERr TVPE � < � 9 .. ............... APPLICATION° V/UU is 44 E`' Use this enclosure with or without knockouts in outdoor 1 97applications 9D 1 ,, ( I 4aD/saoan-uszz as a wiring orjunction box. FEATURES ....�- L,,;v„-17sv1 °° t --• FANKR02-10 - - - - - " Dl ip shield top and seam-free sides, front and back i su = D�{v,;.=4DOV1 • 85 I .. _... Eb l,V�,-480 V; .. ve' V...IVI. <xo I a�g .. Sip-on removable cover fastened with plated steel screws along bottom edge f • Handles on larger sizes (see table) 0.0 oz 0.4 ob 0.8 1.0 • Standard feature O Optional feure at • - IJot available Embossed mounting holes,on back of enclosure ompgtpo,w /RmalpaYer ; Data al nominal conditions knoc 'ng . -----=' • Provision'for padlocking Sunriy Boy 5000TL-US Sunny Boy 6000TL-US Sunny Boy 7000TL-US. Sunny Boy 77007L-US. a, No Basketing SPECIFICATIONS 208 V AC ' " , 240 V AC .' 268 VAC 240 V.AC . 208 V AC .. 240'V AC 208 VAC' 240 V AC 16, 14 or 12 gauge galvanized steel 5300 W 6300 W 7300W 8000 FINISH 600.V 600 V 600 V; . 600 V. ANSI 61 gray polyester powder pain finish inside and out. P t n over f pretreated sur aces:' 175 - 486V 210 - 480 V .245 - 480V 270 = 480 V 125-SOON125-500V _ 125-500V .. 125-500V ACCESSORIES 125V/150Y 125 V•/ 150 V 125,V 150'V 125 V / 150. VN _ - l - - - See also Accessories. 30A/15A '. 30.A%-15 A30A/18A. 30,A/18A Industrial Corrosion Inhibitors. 2� Electric Heater Grounding Device Z 4550 W 5000 W . ' 5200 W 6000 W 6000 W 7066W . ' ' 66501N 7660 VJ. Mounting B,racke Kit t Touch" Up Paint LU Ul X15.50 VA 5000VA 5200 VA 6000 VA. 6000 VA 7000 VA 6650 VA 7680 VA INDUSTRY STANDARDS LLE BULLETIN: `i O -20BV/0 240V/0 208V/• 240V/• 208'V/'• 240V10 208V/c 240V/'r U -i H 183-- 229 V 211 - 264 V. 583 - 229 V 211 - 264 V, 183 - 229 V 211 r 264 V 183 229 V 211 - 264 V UL 50, 50E Listed; Type 3R; File No. E2%525 ~ a In Q U 60 Hz/59.3-60.5 H. 60Hz/59,3-60.5 Hz 60 Hz 59.3 Hz 60 Hz /59.3-60.5 Hz cULListedperCSAC22.2No94:Type3R;FileNo..E27525' H 22 A. 25' A 29,2 A 32A NEMA)EEMAC Type 3R p D 2 IEC 6 524; IP3 �� [V a 1/2 1'�2 1. J2. .. 1/2 Q = O� M <4% a4% <4% , <4%. Standard Product Z J N a'0 a 0 LLl 97.2% " 97;6% . .... 97.0% 97.496 9,6.89a 96.89; 9G,8%' 97.3% B C = � U Y 96.5% 97:0% ' 96.5% 97:0 % 96.5.% 96.5% 96.5% 9b,596 A4R44 4.00 x 4.00x 4.00.. A - - 1:88 2.00 Ln O to 182x102z102 48 51 W H J A6R44 . b.00 x 4.00 x 4.DD A _. 1,88 lA6 B-C p �: U •2 x �4 48 27 LIJ • / 12 0D x152 00104 Al2R44 .bD 305 102 102 A. 188 1 06 8•C 48 U d s x x A61164&00 z 6.W x 4.00 A 27 -C=0 - 2.25 1.06 6-C=0152 U W -" • 152x152x102' 57 27 � w ABR64 8.00 Y b.00 z 4.OD A - 2.25 1.06 B•C-D' Ln . •.•' 203 x 152 x 102 . 57 27 In I1V ABR8 8.00x 8.00 x 4.00 4 A _ 2.25 1.06 F-13 H-1 203x 283 x102 - 57 17 490/ 519/1.8 . 5 :(19:3 % 20.5 / 7.31 - AlOR84 7000k8.00z4.00 A.. _ 2.25 1.06.. 187 / 297 /-190, (7.4 / 11.7 / 7.5) 254 x 203 z 102 - .57 27 617 / 597 / 266. (24:3 / 23.5:/ 10.51 A11R84 12.00 x 8.00 x 4.00 305 x 203 x 101 A - 2:25 1.06 F-G-H-I - 57 27 o 37&/ 240 /,280 'C 14.6 / 9.4 / 11.0) AlOR104 10.00 z 16.0'i 4.00.A -, " " 2;25. 1.06 - 24 kg (53 IbJ / 3a kg (8,16) . 254 x 254 x 102 ' - 57 27� 27 kg / 3.5 kg' 18 1b) Al2R1D4 12.00 x 10.00 z 4.00 A - 2.25' 1.06 L-O-E-F.-G V) _(6016) -40 1C...-t60 *C (-40 °F'..:+'140 °F) 305x254x102. A1213124 12.00 x 12.00 x 4.00 A _. 57 .27 - 2,25 1.06.. C-D-E-F-G.. Z F 129'dB(A) < 29 dB1A) < 29 dB(A) <.29 dB(Aj 305 x 305 x 102 . - 57 27 O •r <-I W < 1 W < 1 W < 1 W A180124 18.00 x 12.00 s 4.00 A - 2,25 1.06. _C• f g Ln Translorme'eis Tron_sFormerless Transfarmedess - Tionsformerless 457005x`102 - 1 57 r 3 27 UI �$ .. >. _ Convection - Fan Fan - 'Fan NEMA 3R AlOR184 1B.00x18.00x4.90 457 x 457 z 1 D2 B -' _ 713710�rs, .1.12 -D-E- I s A@� :d'J ;i' 2B �Jl��ll1� 4�1r��i�Tl�n� w z a NEMA 311 NEMA 3R' NEMA`3R - A066 6.00 z 6.00 x 6.00 A _ f 2'2 5106 C- - 152x152x152 - G 27 N • e • 0. • . AOR86 8.00 x 8.00 z 6.00 203x203x152 A - , F Z 25 ! l pI Ok o s� F-G.H-1 ' rCjr. 0 . A10R8d 10.008 8.00 x 6.00 A - L 1.06 F•G-H-I' o/o O/0 .0/0. 0/0 254x203z152 - 57 27 0/ /0 /O/o •�O/.O %.0/O A10R106 - 10.00x10.ODx600 A - jj } r COMPLIANCE V.ca I�a'W UL 174 i, UL 1998, UC 16998, IEEE1547, FCC Part 15 (Class A & 8), CAN/CSA 022:2 107.1.1 254 x 254 x 152 - L5(EV6i t l,) + r t I L- ° yd° OPPORTUNITY SPRI- Fremont - h�.vl�W�i�d Ley. fa�r+,� Reviewed J r PROJECT D-0051671 "5B 5000iL-US22. 5B 6000TL-USSB 7000TL-US SB 7700TL-US=22 DATE DRAWN 04-20-2016 - 1 CONTRACTOR SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SOLUTIONS - Spec-00263E DRAWN HLLUVIOSO - - DATE CHECKED 04-20-2016 CHECKED BY APATEL _•: SHEET FIGURE A: INVERTER SPECIFICATION SHEET FIGURE B: JUNCTION BOX SPECIFICATION SHEET PAGE 1 . SOLAR-E5 . .. _ .. 96 .. .. . - - f.b . .: . ..- . . -. 1. CD 0 .. _ q, . W - a q . . . .I- �� 1; .. ,� " - I I I � ,4,-� , , , , _- 3: i .::?1.x ._ ' w d;fxx. + .,r..�.:a'i _ i+ . �`t r- -v w .. .: -; w i'. �c: S,ss+K. 4.� 1. �.�;�,.m`�a-+;.rYkz;F+� r XGA". .;.,:,-.a al• ;-s�.10,5 ? .: r'a.,...::E. �' U o u . ., . 1 c„ O "I -� rR .• ., o xhc TYPE 3R SCRF'A'-CVAR TYPE 3R 90XES AAD FIX10.5IIRES ~ n Z W x a �' v' = §. . '.. ¢� . .. ... S'U N POW E R SUNPOWER MONITORING SYSTEM Q- �. ,< .1 O 2. J t PV SUPERVISOR CL .. V �. Uo . 'Al2R86 - - ' .. - 12.00 x 8.90 x.6.00 . ... A : • - ' . . • . . ' : 215 - - '• . 1.06' ' ' : F-6*1- - ' • .. - Al2R106-.. - 12.00 z 10.00 x 6.00: A 2-25 1.Od C D E F-0 _ +„ . .. '305 x 254 x 352; 57 77 . . - .. _ . . .' .- Y W. . . .. .. . 305 z 305 x 151... _ 57 : 27Y: -----,--`, . - . . . - 5 stem Connection Didgram "I 1, . .. ,A1. I . .15:OOx1Z00x6.00 . , - .. 2.25 - - .. . 381 x 305 x.152 - . ' 57.. 27 : %r ' . 96ADx1Z00x6.00 A 215 " .. T A16R126. 1.Ob. C.p-E_F.G '4': 1 . 406 z 305 x 152 - . ' 57 27 �. A18026' 18.00z12:00X6.00' : . A .. _ 2:25 1.06' : - C-0 6- - , r x .. 457 x 305 x:152 57. 27 Onsite Cat 5 Ethernet .. _ .; z . . ' 4118186 18.00 x 1,BA0 x 6.00 ' - B . . - . 13.00 1.12 ' A-8 C D E-F-G*1. �,? ` . intemeVI.AN Cable .. ' COLOR KEY' . 457 x 457 x152 - 330" 2B _1F AC Power SunPower supplied component or cable A24R126 2L.00 x 12.00 x 6.00 B - 13.06 1:12 C•O:F-f-G q •A- _ Supply Installer supplied, SunPOwef cpecified . . . : ' . • ' . '610 x 305 x 152... .. _ - 330 - . 2B ' IAN1 IAN2 - . A24H186 24:00 z 18.00 x 6.00 B - . ' 13-00 .. 1.12 . A 8•C O=E -F -G H I . , ,_;: _ .. i 610 X 457 X'152 - 330 28 . ,� .. . bun 1 r A24R246 :. 26.00224.00X4.00:-. . 8 .. _ 13AD .1.12.. .. A-8- C D E=F•G H•I r . . _. •. 610x610x152 ' .. _ 330 ..28 - -- T .. A0R00 B.00 x 8.00 z lA0 A .. _ __ 1.D6 F-G.H:I -1 PYSu'p ivisor 203 x 203 x2D3 5T• Y7 40 Optional . P7 B2 .. ,F . Al2R128 � , • . 12.001112.00x 8,00 - , . . A :. ' . - - 215 1.06 . , . C•0 E -F -G' - - - - - - - - - - ., . 305x305x203 - 57. 27 : r -- ------ - -- -- - -- A15R128- ., ' . - 15-D0 x 12.00 x 6.00 A .. - 225 1.06 C -D -E -F -G nssory Kit , 1 T Su . Borden 31o6A • Belden 3106A or Cat 'Or < SunPower Accessory Ethernet .C-diernat _ -:,4 . - . _ - - ais -chained Cable ' - 381x305x203' _ 57 27 - pct �0 de o .. A18R12g'' 18:00X12.00x8.g0. A - .2:25' 1.12 - •0•E•F•G. h4 -t:. Bel n3106A. o Beldan3106A AceessorylGt ( Cable , Cable . -. - B . . . ,.� • . :DB9.Adapter' 1 Imier•s,r1 L�JU45 U ..$ %,--,-;. LU .. 457. x 305 x'203, . - 57 ' 2 . _ .. �.. . N A24R168 ` . 24.00 x 16.DD X 8.00 B . 13.00 1.12 C D. E•F-G' q e4, MET System, . R i . 610 x 407 X 203 - . 330.. 28 €7Q , Production rtris'or., ZO Station 1 .. A18fl188 - . .: ,18.00218.00x 6.00: .. ' ' B 13 DD 1.12 A•B-GU-E-FG•Hd ' 1• . . - - TB oak ! PV Meter 1 } r , Ln . . :.457x4572203 - 330 20. N as:_' 1. . ..------------------ --_.J . . +� ¢`4 Q .. .. . .- A24R15B 24.6008.00x8.00 B - 13.0D 1.12 ' __ A -1 -66 -Elf -64.1I. .. F¢'- O. U . 610x4572203 _ .. 33D 28 . .•r AZ4R208' .• 24.00x20.00x8.00 B'. - - 13.00 .1.12 .A -g -C -044 -G -H.1 �, h " Z O .. �. Q Q �-. � Z. W b10x508x203' 330 28 t' 7? .. N y A24R24B 24:00x24.00x0-0.0. C .. 12,19 . . 13.00. 1.12. A•B•C,444-G-Ha n O - 7 �. _.. O M' �. . .. 610 x 610 x 203 . 310 - . 33D.. TB * r* LL - _ s:1 to r� O O Q O A30R248 30.00x24.ODx8.00' C 15.19 13.0D 1.12 A11CDEFGHI - ¢, , . >, P1,. _1 I -ISO 1, I Ip Z. Y. J N °� _ .. g 386. gyp. 28 �.s,-I.CC _ ¢ w . .. 7d2xb10x2.3_.. .. - _. . . . .. ':. . : _ ;<,v ., .. K, Q. O ¢ - - 1.50. A:6=C D-E-F•G-H. O U r A4BR368. ' , . 48.00x3b.ODxB.00. C 24.19 33A0. ?,js Dimensions N% 6 -,;. . , _ 0. . echanical Data Plus Enclosure 1219x914x2o3 . PRf,:SPRm Iriveders, Supported . A .,, p y ¢. . . - . ' _ ' 614 , . .. 83B - - : 3 , Z"-.. Inverter Compatibility -76(26 X 4 31(l ] l J X' 3.03 77). �tr , n 00 10.00 8 : - "13.00 ' 1.17 - • - A-B-C-D-E=F•G-H-I 4 SatCon and Santerno Inverters - A18R1810 .. iB.DOx 18 x W . Ln" Z .. - 457 x 457 x 254 . - - _ . 330 ... 20 . '_ ;.. .. ' N,�a �. -, ,--t ' . Q A24R1B10 24.00x18,00210,00 B .. _ 13.00 1.12. AB•C-D-E•F-G-HIa:' p. +� . x x , in cm .. Weight U - .610x457x254. . ' ' .. . . _.. 330 . 2g, . NUmber of Inverters . 19.0 g .. - .. w � I.' /Pocked 1!Jeighl, lbs {kg) :-H" I a . A24R2410 .. - 24:00x24.00x10.00 ` - ' C " 1719 . , - .. - 1300 ' : - .1.12 A B C O.E-F:G-.HI - 4 Supported' C7 . • . ' _ . 610x610 x754 I. 310 330.. 28 - �N;� , ``� U Up:ro 30 A30R2410 3D.D0 z 24:00 x10.00 C 15.19 ' 13.00 1.56 A -B -C -D -E -F -G -N -I. a".' R . . 4 . . • ' ' 386. . 330 . 38 .. iAi'Ir Enclosure sting . se LU 76Zx810z25 -rJ1. ', .� .. W . Wired from PV $uperpisor to Customer A24R2412. ' 24AO x 24.00 x 12.00 C 12,19 13.00, . ' ,1.12 A-B-C-O-E.F•--H-1 - System, nType Supervisor . to (optional . - . al .. , y,5 .. bib x 610 x 305.. 310 ' .. ' 330.. : 28 . .* • Wired from P . -' - - - O tional 15- 127.00 150 A -B G-D-E-F•G-H-I ' •• .. A aila6le w .. A30R3012, .. .. 30.D6x30.00x12.00 C - a, " .. :r, Conned io V Visor Ilular . .. ':u a Mounting I -Mount Hardware 962 x 762 z 305 386 686 38 $ a ^ �a 9 ' 27.00 1.50. ABC -D -E -F -G -H-1 : ° ' '" Transmission Ran e. 330 ft' 100 m via Ethernet. - A36R3012 .36.00x30.00x12.00 C ' ; . 16.1 9 ( . Operating: -10 to•+60 . r . u . . ' 914 x_761 x305 . - ' : 462 ' 606 ... , .- ' . 38 . ' ' Tem peratu _ _ - 16.19... 33.00 150 A B -GD E F.G.A_1 Operating re A36R3612 . . • : 36.00 z 36.00. x 12:00 C 914 x914 x 305 .. 462 . 838.. 38 . _ . . �,; Power Source External AC Source (100 '240 VAC, < 5Wj Storage -20 to +13d C "� .n,h,i .. in nn�in'dn.tRnn r t5ty 7700 1-5D' :A-B•C-D-E•F-6-H•I � I,Iav<-.. . - . - .,� a 762X7d2x408, . 386. - ..666I . I - .I I. � . . , , I I , - * , , ^ , , , � - - I � , - . . . . I . - , , i '. ' `38r I - 'A4T :-, _. 1.50 , '_ " :: - :,,aa y a `s ., 1. Weli'SUpport,- s _' a„ •. ., -.: =- $ ., `� s *"J'wi� Xslte?R uir`ements i .; �; t Y.,K a • �j` w', .: - -A WOITd11I Gn(1 Ce�tlflCC�lO11S A a FA10R84NK .•. 01, r.: Internet 6.0, 7.0 .. Safari r • Sunpom Inverters Sii r l°, ea�, . p rteei oCK bn Al2R84NII .. 12.00 x 0.00 x 4.00 A - 225 - 305,%203x 102 . , . ' . . 57 27 . ' •. . t Ti.i' Browsers Mozilla F �efox 2.0s6ft X3.0, 3.1.1 A48R3d16 48r00x3d.00x16.00 C 24.19. 33.00. A-B-C-O-E-F-G-H•I?Y_ : 1219 x 914 z 406 - .. ` . 614 B38. . 38 �r - Data Storage 60 Days L in Website www.suripoWermonitor.com ',� z 1 � • $ PP rted`CeIcove�rage� ss�� y, �I ,_,-_ :o,....rimRxr�_ 6Ef /---f-'/ I r x -" OPPORTUNITY SPRI- Rt -Fremont . . AAR44NK . .. -- 6:00x4.00x4A0. - A -. .1.08- 2.00 - . . A, % � . .. Warranty - i r anty 5yearlima r p Upgradeabilily . Automdlic Firmware Upgrades 102%102x101 _ - :. 48 51 A6Rd4NN b.Opx'6.00x4:00 A _ 225 1.Od _> 152 x 152 x 102 - 57 ?7yp ." .,. r; ",: N hfi Car calsus' 1 [ 4 • -� r 1 1 M I FCC Part ;�` s iiih8a1� ! ABR64NK, 8AO x'6.00 X4.00 ' .. A - /� - - r 1 - III �u '� _ . ,� / .�3 E l .. _ k.J i.� l l Intl, ti. Ca .� _ , , .i I a l I I -I' I ' I I I I I I I I I I - 203xl52x102 .. - ..57' .. '27 . A8R8LNK B.00 x 8.00 x 4.00 A - u5 t.un 203 x 2W x 102 _, gy 17 i .. .. 725 . ' 1.Od .. - .. . - - 10.00 x 6.00 x4.00 A' _ - 254x203x10Z - .. 57 . 27 1.08 '_ , '_ " :: - :,,aa y a `s ., 1. Weli'SUpport,- s _' a„ •. ., -.: =- $ ., `� s *"J'wi� Xslte?R uir`ements i .; �; t Y.,K a • �j` w', .: - A a FA10R84NK .•. . o W 0 Internet 6.0, 7.0 .. Safari r • Sunpom Inverters Sii r l°, ea�, . p rteei oCK bn Al2R84NII .. 12.00 x 0.00 x 4.00 A - 225 - 305,%203x 102 . , . ' . . 57 27 . ' •. . t Ti.i' Browsers Mozilla F �efox 2.0s6ft X3.0, 3.1.1 and SanettKemo�Inverters - bi�L pii� I , � URS CO i l L in Website www.suripoWermonitor.com 1.06' _ . . AIUR104NK,' ... . 10.00 x 1D.00 z 4.00 A : - - : - 2.25 . s ... :.- • 254x25ix162' - .. - .- 57- .. - ' 27 Al2R104NK 12.00XTO.00z6.00: A - Z25 1.06: - 1 � • $ PP rted`CeIcove�rage� ss�� y, �I ,_,-_ :o,....rimRxr�_ 6Ef /---f-'/ I r x -" OPPORTUNITY SPRI- Rt -Fremont . 305 2254 x 107 .. - . 57 27 I meF w -w- i - j : .r rnuJeu u-uuxion . .. . r; - - ' . JJNPOWER and the SUNPOWER logo aro trade=6or regletorodtrodemorks of SmPowor Corpddion. _ sunpowerCOrp.COrri DATE DRAWN • 04-20-20i...... .- 66 .. . .. .. . • - . - @ nwy 1 SunPower Cdpordion. All nghh rrserved. Speohtoi Inducted In thli ddashee rffe srbled to rhdnge without ronce.• 0.5 L - . .. '� Feb' 207 DoarmeniR001d0.5 Fw"/ 71?`FN -1 E100MENTPROTECTIONSOLUTIONS PH 743.422,2211'•W763:422.2600 HOFFMANONLINE.COM. CONTRACTOR .2 L-- _ I . .. .. Spec -00263, E : . . - . -. - I ., DRAWN BY. HELUVIO50 . - _ . .. _ . .. .. .. ,_., _,: :' DA NECKED � 0420401 'moi' :- .. , • -. - .. - - - CHECKED BY ' APATEL ., . . . - . • . - ' .. ' .. . . ' .. - . ' .. . .. : . ' .. .. . . - .. . . . .. . . - .. � ' .SHEET .. ' .. .. FIGURE k JUNCTION BOX SPECIFICATION ,SHEET PAGE 2 FIGURE B:. PV SUPERVISOR SPECIFICATION .SHEET _, .. .. .. .. .. . . .. - SOLAR -E6 in ",. �r f Ln W W ~ to In In co o OD >rn Ln m �3 to a m ME (� S U Irl P 1N E R S INPOWER CORPORATION 3 a u Safety,and.lnstallation Instructions - Document 001-14158 Rev S Z o W .o in V) �= 20,a F o m Z .-. 'Z =5558g g Do' not stand on, drop, scratch, or allow objects to fall on modules as it may Z 12 Safety and Installation Instructions damage and void the warranty. o _ _ M d C Do not plate anything an the modules, even for a mo be cause resulting . ment v <. . (United States an anada). .. residue may damage orstain the glass surface. o u v • If the front glass is broken, or the backsheet is torn, contact with any module 1'0 Introduction . - surface or module frame can cause electric shock. This manual .provides safety and installation instructions for UL Listed • Broken?=boxes or connectors are electrical hazards as well as laceration SunPOwer photovoltaic (PV) modules that have the UL logo on the hazards. Installers should.remove any such module from'the array and product label: contact SunPower for disposal instructions. • Do not install or handle the modules when they are we or -during periods of D'hh UL wind. US r Sun ower recommends a conservative minimum cable fiend radius of equal' E. to or greater than 40 mm (1.5"). Contact SunPower If maintenance Is necessary: IMPORTANT! :Please.read "this manual in its -entirety before . Save these instructionsi. instal ling' wiring' or using this.product In any. way. 116 -to comply .with ctions will invalidate the SunPower Limited ,' 2.1 Safety and Installation .Instructions War Modules • ntyforPV Them due fire rating is Type 2 per 'UL3703; 2013 edition and Class C per 111.170.3, 2002 edition. Fire rating classification for any PV systemusing . UL1703:2013 can only establish a fire rating in, combination with the mounting United Canada. 23 D/sclolm er of Liability system ratings normally found in the mounting system installation instructions. .States and The installation techniques, handling, and use of this product'are beyond . company control: Therefore; SunPower assumes no responsibility for loss;. . 3.0 Elet rlcal Characteristics damage or expense resulting from Improper installation, handling, or use. This doCUrllent:applle5 to all SuflPOwer modules. Electrical characteristics ofth'e modules are described in Tabled below. Each listed in Table 1. 1.2 UndeitvrRers Loborator ation Laboratories (LIL) Listing I»form module contain three'bypass diodes. F all modules, th :ma -mum series fuse 5 0 For the'maximum ' This product meets or exceeds the requirements'set forth by UL 1703 and rating is 1SA: . - ULC/ORD-C1703-OS for PV Modules. These Standardscover flat plate'PV modules U) Z and panels intended for installation on buildings -or those intended Tobe Table 1: Electrical Characteristics' O This. document includes references .to SunPower E -Series; X -Series, and :NE freestanding. To satisfy the Listing for this product the modules. must be mounted Volta eat' current at Maximum g open Circuit U I..I ,-I o: H Q - - modules. These ,modules do. not Have grounding restrictions 'and all are g g w6 a rack orstandoff structure. The Listing does not include integration into. - buildingsurface. because apply. Rated Pnwer - Short Circuit System Module. Rated P -r Rated Power, voltage (wi current, Isc(A) Voltage UL' Vmppty) Impp IA) (vl Q . �% p) � ' U . compatible with high-efficiency'transformerless inverters.�. additional requirements may This product is not q Y . PP Y• P - vmax � a' � intended for use where concentrated sunlight is applied to the module. ' : n- R sP-xxz-36ocoM loon - w z. j� . • U - 360 60 6 5.94 69S -6.48 SPR•1Q2-360- ' 600 n O' = O IN W a _ Contents of this manual are subjectto.change wfthout:notice: 1.3 Limited Warranty ' � sPR•:al-3ascoM 1000 U) H o En - .. -' .. .. For the latest US & Canada. manual please refer to www.sunpower:com/R VlnstallGuideUS Module limited warranties are described in full i the S ow warranty b n unP er w ranty certificates obtainable atyirwwsunpoweccom: Insummary; the limited ' 3 6 68:2 ' 6.39 345 � S7 � sPq xz1.343 600 z Q. _ a Y J � < (V Lu ' Q SPR -X21, � _ O . wa Warta � � � � � 335' � 573 - � 585 679 � 6.23 � 600 Lu- - } � d Q . Sun Power CorporatiDin Modules whic.hPI nlSunPower''s absolute udgment nave been sub ected to.misuse, j - SPR-X2o.3z7rDM 10DO _� ~ z � � _ . abuse, neglect or:accid alteration; or nstallatlo tion or ent; alt improper Installation, applica, . �. .-•I Q - w.ww sunpoW.er.Com removal. This includes; but is not limited to, Installation, n;application;orren(o al v SPR -X20327. 327 , 57.3 571' 67.6 6.07 606' , ,' TI by'any.partyotherth'anaSunPowerauthorized•dealer;'non-obs of sPa-xza3z7�uc . � ; -a. � e repair SunPower's installation, user's and/or maintenance instructions or srR-x3z-z7s ' 27s a.e 6.14. 52.7 6s4 soo . . � � Modifications :bysomeone other than an approved service technicjari ofSPR•x2l=zss 2ss 4z.e s9s s3 6.3 - 600 U J SunPower; powerfallure'surges, lightning, flood, fire; accidental breakage, or _ . ' u j other events beyond control. SPR -i20 -256-M. � .250' . 42.8 S.&1 � 509 6.2 600 � SPP -X31-245 : 245 42.8 - - 5.72 50.8. 6.118 600 In .. .. . 2.0 .. '. 2.0 safety Precat tlOns SPR•X39.330 310 57.3 5.41 67:2 5.82 .600 boo - - u Before Installingthis.product;, read all safety Instructions in this document. PR-x19=24o41LX 246 4x8 • 5.61 56.6 - ..5.98 son . - - - - SPR-E20d40LOM 440 72.9 6.00 86.5 6.S .1000 m . DANGER! Module interconnection cables pass direct-current'(dc) and SPn•Ez0I43scoM - .3s 7x9 s.9�. ss:6 6A3 10DO " o are sources of voltage when the module is under load and when it is � sPR•E79a1DioM . • a1n . 7x.9 s.6z' as3 - 6.D1 • l000 . . .' . • .. -. exposed to Iight..DJrect current can arc across gaps and may cause . SPR -E20-327 - • ' 600 � 3v sa.7 : s 64 a 6.46 N - injury or death if improper connection or disconnection is made; or .4e SPR•E2o 3nroM .. _ 1000 j z 0 if contact is made with module leads that are frayed or torn. DO not SPR E79320 I' r 31i y r ` i 54.7 5.86 .7 �. 6.2 600 N connect or disconnect modules when a:current source. is energizing SPR-C19-31554.75.7Qji i I !M > - . the conductors. Modules may contain highvoltage when. sPR•Ei933otoM'i; 3$2 y. d-" .54.7 5.67.- 64A 6.05' ''1000 W Z ' - - interconnected with other modules: - SPR-El8 29scoM ' 29�• t 54.2' 5.45 .639 S.83 10D0. SPR -C20.245 6.470.iIH11,00' . (n > 9 All Installations must be performed_ in compliance with the National Electrical SPR•E39295 �' . 40.5 ' S.8 .. 48A � 6.115' 600 p - Code (NEC)and any applicable total codes. SPR70NE-Bill 2 gp.5 ;_ S.ilt ..� _.482, �' ,05, • For Canadian jurisdictions, installations shall be In accordance with CSA C22.1, OPPORTUNITY SPRI- Fremont W Safe Standard for Electrical Installations, Canadian Electrical Code, Part 1 3.1 Bypass Diodes tY Reviewed By Document 001-14158 Rev S There are no user -serviceable parts within the module. Do not attempt to PROJECT" D-0051671 a` P/N 100345 repair any part of the module.. ( For all models the Maximum System voltage for IEC Standards is 1000V and installation should be performed only by qualified personnel: maximum .serles fuse is 15A. For models not shown here, please contact SunPower hnical support or visit www.sunoower.com. Electrical parameters are measured at DATE DRAWN 04-20-2016 it Standard Test Conditions.(STC); DRAWN BY HLLUVIOSO - - - - O 2015 SimO werCorponUon: All rights reserved. SpeoRratiuns Included in this manual arc subject to change wiLhoul notice. Page ( 2 DATE CHECKED ' 04-20-2016 - N i. - .. ., .. •. .. cr CHECKED BY APATEL . FIGURE A: MODULE INSTALLATION MANUAL PAGE 1 FIGURE.B: MODULE INSTALLATION MANUAL.PAGE 2 SHEET .. - : .• ' SunPower E -Series, X -Series, and NE modules To reduce the possibility of electrical shock, ground the frame of the module or have no grounding restrictions: array per NEC before wiring the circuit. In order to install in accordance with their When using methods 2, 3, 4; 5 or 6 the module mounting structure must be SPR-EYY-ZZZ SPR-XYY-ZZZ-BLK UL Listing, SunPower modules must he grounded using grounding hardware that grounded as per NEC 250. To ensure system safety and structural integrity, strict SPR-EYY-ZZZ-BLK SPR-XYY-ZZZ-COM meets requirements for grounding systems in UL 467, UL 1703, or UL 1741; on adherence to application-specific SunPower documentatlon is required. SPR-EYY-ZZZ-COM SPR-ZZZNE-BLK-D anodized aluminum frames. SunPower recommends using one of the following 4.2 System Grounding SPR-XYY-ZZZ SPR-ZZZNE-WHT-D of. methods of grounding the module frame. In addition, to avoid corrosion.due to Review the Table 2 below for the proper grounding techniques for the Installation IMPORTANT) For optimal performance, SunPower modules listed above the use of metals SunPower recommends stainless steel between of your particular SunPower modules. comply with this requirement will reduce system performance and copper and aluminum. For the Generation 5 (G5) frame, only methods 1 and 2 Module apply. Table 26 Module Grounding Key mount clip P f Ln mount For.oasls (down) size color) (Al) LU UJ o 0 °i F rb � N v o bb a 8 z J U < S U N P O W E R� SUNPOWER CORPORATION S U N P O W E R�' SUNPOWER CORPORATION 0 in a o mai Z o W " G5 (black) Safety and Installation Instructions - Document 001-14158 Rev S 50 400 Safety and Installation Instructions - Document 001-14158 Rev S 2 O W o o in 2 o C ra`e Bypass diodes are factory installed and are not user replaceable: The diode 5) SunPower modules may also be grounded using a WE -9.SNLground clip in Figure 1: Mounting locations for SunPower modules 5) SunPower-specified or SunPower-supplied mounting systems: Mount Z I 'o Z LU a O O u rr a e �t x configuration for 96 cell modules is 2 diodes for 2 strings of 24 cells in series, plus one diode for a single string of 48 cells in series. For 128 cell modules, the -EB between the module and supporting structure. This combination is secureda with a 1/4" stainless steel rivet ora 1/4-20 by 3/4" zinc -plated bolt with --; I � 81 i C1 >1 1) Frame Holes: Secure the module to the structure using the factory mounting holes. Four 1/4" stainless steel bolts, with nuts, washers, and lock � o x = a u a � � ,.., g � a configuration is 2 diodes installed for 2 strings of 32 cell in series, plus one diode for a single string of 64 cells in series. The diodes are one of the following ratings; zinc -plated K -nut torqued to min. 6 ft -lbs to secure the module to minimum 12 ga. G90 coated steel or Z -porton, either painted or unpainted.The WEEB- — — a 1- washers are recommended per module; tightened to a min. torque of 10 in- to Table 4 for the module dimensions lbs. Refer a sand hole locations. This G3 (black) o u U v ., - € ° 1. Schottky type, 15A, 45. Peak Inverse Voltage (PIV) for 96 cell modules. 9.SNL is for single use only. LL method has been certified by a third -party organization according to UL G3 (black) 150-380 332 96 cell Any Silver 150-380 332 128 cell 2. Schottky type, 20A, 45 PIV for 128 cell modules. G) Other grounding methods may be used in conjunction with a module mounting Frame Hole mounting Locations Al 1703. For frame hole mounting, modules must be secured using the holes 3. Schottky type, 20A, 100 PIV for 96 and 128 cell modules. 433 located at 322mm from the short end of the module for 72 and 96 cell Mcell 4.0 Electrical Connections system tested to UL2703. For these installations, the SunPower module and frame style must be tested and part of the instructions for the listed mounting The SunPower module must be Installed in accordance _ - J u modules and 433mm from the end of the module for 128 cell modules. For carport installations the supporting structure has been pre -drilled. For 128 product. cell modules for carport assembly, modules must be secured using only the Modules may be connected in series or parallel to achieve the desired electrical with these instructions as well as the mounting stem's listed instructions. g s y holes located 433mm from the ends of the module and hardware described output provided certain conditions are meta above in Section 4.1, Item 5. See Figure 2 for carport assembly details. 7) SunPower GS -frame modules may be grounded through the use of an r 2) Clamps or Clips: Mount the module with the IFF clips on the longer sides of SunPower recommends using the same brand/type of dc'home run' connector as InvlslMount'" mid clam that bonds the module frame to the InvisiMount'" P the module. The centerline of the clips must be 2-16" for G5 frame (6-15" on the module it connects to. This helps insure compatibility. rail. InvisiMountTM rail sections must be bonded and connected to a for G3 frame) from the corner of the.madule. Ensure that the clamps are of grounding conductor using methods and materials specified in the Table 3: Mounting Configurations and Load Resistance sufficient strength to allow for the maximum design pressure of the 4.1 Equipment Grounding InvisiMountTM manual. SunPower E -Series, X -Series, and NE modules To reduce the possibility of electrical shock, ground the frame of the module or have no grounding restrictions: array per NEC before wiring the circuit. In order to install in accordance with their When using methods 2, 3, 4; 5 or 6 the module mounting structure must be SPR-EYY-ZZZ SPR-XYY-ZZZ-BLK UL Listing, SunPower modules must he grounded using grounding hardware that grounded as per NEC 250. To ensure system safety and structural integrity, strict SPR-EYY-ZZZ-BLK SPR-XYY-ZZZ-COM meets requirements for grounding systems in UL 467, UL 1703, or UL 1741; on adherence to application-specific SunPower documentatlon is required. SPR-EYY-ZZZ-COM SPR-ZZZNE-BLK-D anodized aluminum frames. SunPower recommends using one of the following 4.2 System Grounding SPR-XYY-ZZZ SPR-ZZZNE-WHT-D of. methods of grounding the module frame. In addition, to avoid corrosion.due to Review the Table 2 below for the proper grounding techniques for the Installation IMPORTANT) For optimal performance, SunPower modules listed above the use of metals SunPower recommends stainless steel between of your particular SunPower modules. comply with this requirement will reduce system performance and copper and aluminum. For the Generation 5 (G5) frame, only methods 1 and 2 Module apply. Table 26 Module Grounding Key mount 1) Attach a lay -in lug (Ilsco GBL-4DBT, Burndy CL50-DB-T or Tyco Solklip 1954381- 2) to one of the grounding holes on the module frame, and attach the ground conductor to the lug, Use stainless steel hardware (bolt, washers, and nut). Use an external -tooth star washer between the lug and the module frame in order to pierce the anodizing and establish electrical contact with the aluminum frame. The assembly must end with a nut that's torqued to 20-25 in -1b (for a 410-32 bolt). A lock washer or other locking mechanism is required to maintain tension between the bolt and the assembly. The. conductor must be attached to the ground lug using the lug's setscrew. Refer to NEC 690. 2) SunPower modules may also be grounded through the use of SunPower IFF A 7 1 IFF I' t I 355 Module Model Grounding Key1 SunPower E -Series, X -Series, and NE modules Legacy modules must be have no grounding restrictions: positively grounded: SPR-EYY-ZZZ SPR-XYY-ZZZ-BLK SPR-ZZZE-WHT-D SPR-EYY-ZZZ-BLK SPR-XYY-ZZZ-COM SPR-ZZZ-WHT-D SPR-EYY-ZZZ-COM SPR-ZZZNE-BLK-D SPR-ZZZE-BLK-D SPR-XYY-ZZZ SPR-ZZZNE-WHT-D SPR-ZZZ-BLK-D IMPORTANT) For optimal performance, SunPower modules listed above as needing positive grounding must be configured as described. Failure to comply with this requirement will reduce system performance and invalidate SunPower's Limited Power Warrantyfor PV Modules: Module Mounting configuration Configuration (valid mounting location in mm) Load rating Wind (up & Frame Pressure Oasis W tt;pe End clamp or Frame Center down) /Snow Module (frame mount clip P holes mount For.oasls (down) size color) (Al) (Bl) (Cl) onl4 z J U < SunPower IFF clip 450920.6 may be substituted for the Everest Mid Clamp, 3007400 W Z .~W � U 4000Pa / 8000Pa 72 cell G5 (black) 50-300 50 400 Q F- 2 O W 4000Pa / 40bOPa module; on 72- and 96 -cell modules mounted in landscape orientation only. Z =O Y � N 5) SunPower-specified or SunPower-supplied mounting systems: Mount 300=400 a Q W Q 3000Pa / 6000Pa 96 cell G5 (black) 50-400 50.400 f 7 ri 3000Pa / 3000Pa 72 cell G3 (black) 50-250 150=380 332. 240OPa / 540OPa 96 cell G3 (black) 150-380 332 96 cell Any Silver 150-380 332 128 cell Any 400-460 433 240OPa / 240OPa Mcell Center. 215OPa./ 3100Pa module. The IFF clip hardware must be tightened to a'torque'of 35-45 In - lbs. 3) End Mount: End mounting is the attachment of the shorter side of the module frame to a supporting rail. using IFF clips tightened to a torque of 35-45 in -lbs. The centerline of the clips must be 2-30" from the corner of the module. The end -mounting rail and clips or clamps must be of sufficient strength to allow for the maximum design pressure of the module. Verify. this capacity before installation. 4) his Solar Mounting System: An Everest Solar Mid or End Clamp can be used to secure the shorter ends of the module. When using Everest Solar mounting hardware. The Everest Solar stainless M -K2 Slot nut is placed in W the channel of the aluminum Dome D1000, Dome 51000 or Dome SD Z mounting component. The WEEB KMC grounding clip is placed under the N O bottom.edge of the module. The Mid or End clamp Is placed 'over the top U o F - edge of the module frame and secured to.the M -K2 slot nut using a stainless Q Ln U MB.bolt and stainless Belleville washer tightened to a min. of 16.3 ft -lbs. A z J U < SunPower IFF clip 450920.6 may be substituted for the Everest Mid Clamp, r -i O Q W Z .~W � U but only when the modules are being installed using SunPower's 010 or 510 > o_' (V W CL product. Two clamps must be used on each of the shorter ends of the. Q F- 2 O W m Lf) module; on 72- and 96 -cell modules mounted in landscape orientation only. Z =O Y � N 5) SunPower-specified or SunPower-supplied mounting systems: Mount Q a a Q W Q modules with strict adherence to SunPower documentation, using 2 O . O0 r o! F- 1. -..,a... -..,....6..d r ... ... .......r(L..a r... G... n...L... f 7 ri d n clips which are UL Listed (1703 an 1 4 )..! c Ip .orque va ue a m- -- -, -- - -- --- -, ,,, — lbs for a l/4-20 or M6 bolt, but may be higher in specific applications. LUr-, J Excluded Operating Environments ~ +-+ When using IFF clips, the module mounting system must be grounded as 5.0 Module MountingCertain operating environments are not recommended for SunPower modules, 5.3 Module Handling '-' U per NEC 250. The SunPower Limited Warranty for PV Modules Is contingent upon modules and are excluded from the SunPower Limited Warranty. Use gloves when handling modules. The module glass Is sensitive to oils and Wa � being mounted in accordance'with'the requirements described in this section, abrasive surfaces, which may lead to scratches and irregular'soiling. Do not place C7 U 3) SunPower modules may also be grounded through the use of an Everest Solar ?� U W Systems Mid or End Clamp assembly. The assembly consists of a stainless 5.2 Mounting Configurations modules such that the glass comes in contact with abrasive surfaces, and J M -K2 slot nut, WEEB KMC grounding clip, Everest Solar aluminum End or 5.1 Site Considerations Modules integrated into or mounted over a roofing.system must be mounted minimize any contact with the glass in general: Do not place anything on the iLq 0 W modules, even for a moment. Remove any fingerprints byw'ashing the module Mid clamp, stainless M8 bolt and stainless Belleville lock washer. The WEEB 5unPower modules should only be mounted in locations that meet the following over a fire-resistant roof covering rated for the application. Modules may be Lr) Is placed under the bottom edge of the module and the clamp Is placed on requirements: mounted at any angle, from horizontal to vertical. To reduce soiling, modules glass as described in Section 6.0 below. the top edge of the module. The boll captures the Bellville washer, the should be mounted at a minimum of 10 degrees. clamp, the WEEB and the M -K2 nut and must be torqued to min. 10.3 ft -lbs. Operating Temperature: All SunPower modules must only be mounted in 6.0 Maintenance and Cleaning This method Is valid when the modules are being secured to Everest Solar environments that ensure they will operate within the following temperatures: Residential (black) module frames have two profile types, G3 and G5. Commercial Trained SunPower dealer or trained SunPower support personnel should inspect g aluminum Dome D1000, Dome 51000 or Dome 5D mounting components. A (silver) module frames have permanently attached stacking pins. Mounting all modules annually for safe electrical connections, sound mechanical SunPower IFF clip 4509206 maybe substituted for the actual Everest Mid 40'C to +85'C system hardware used with commercial modules must account for the presence connections, and freedom from corrosion. o Operating Temperature range -40'F to +185 'F of these stacking ins. Mechanicals specifications for modules are shown In Table Clamp itself, but only when the modules are being installed using B P . SunPower's D10 or 510 product; with 72- and 96 -cell modules only. The IFF 4• Periodic cleaning of module glass has resulted in improved performance levels, N Z clip must be torqued to 35-45 in -lbs. When the end clamp is used for Care should be taken to provide ventilation behind or underneath the modules, especially in regions with owlevels of annual precipitation; therefore SunPower o securing the last module in a row, the last module must be separately especially in hot environments. In order to prevent water from entering the junction box, which could present a recommends periodic cleV,nj -gof tk M dules. i Ln grounded when servicing the adjacent' module. safety hazard, modules should be oriented with the junction box in the I W' r: ''v11 I t 1 N Design Strength: SunPower modules are designed to meet a maximum positive uppermost position and not be mounted such that the cell faces downward (e.g. To clean a module, washlitl { Iass�s5`rface with potable, no?ir_lie6(e)� a n Note: Method 4 is evaluated to UL 1703 by ETL As such, the use of these devices cmayrtn if�'i1� � (or up/dawn, e.g. wind) and negative (or downward, e.g. static or snow load) on a tracking structure that positions the modules with the junction box facing Normal water pressure 14'�' e te;'6u`t� pressurized water (up to 1500 psi) may � l is not considered part of the UL Listing of these modules. +; -r I _ design pressure described in the Table 3. Design strength of 240OPa wind load skyward during sleep mode). be used. Some fingerpri tains;olaocumulations.of dirt on the glass maybe g corresponds approximately to a winds eed of 130 km/h (approximate 1800 Pa, �4-s •_ =+ as a t i. :ark n 4) If the Unirac SOLARMOUNT system is used for mounting the modules, P PP y P IY removed with over -the- QME5 s cleaners (such as Windex or equivalent), or P .?rl grounding is achieved using either a BURNDY Wiley WEEB-UMC or WEEB- per IEC reference) with a safety factor 3 for gusty winds. Modules have also For 128 -cell modules a minimum of 4" of clearance between the module frames with a 3% soap -and -water solution. For smaller systems, wet the mo.Jule glass UGC -1 grounding clip in combination with Unirac's Mid or End clamps and been evaluated by UL for a maximum negative or positive design load of 30 psf. and the structure (or grrade) is required; for all other modules a minimum of 1.5" with the solution, let it st dfor, w r'n4tes,.ar,d then wet them again and use a ��1.. p�ue�rrlI rrci - 9X�1ANCE IJ4-20 bolt and flanged nut, torqued to 120 in -lbs: If the Solarmount-I Figure 1: Mounting locations for SunPower Modules shows where to mount to of clearance Is require soh sponge or seamless'cRfth t� ep`r�t�e gIa(s ,t�rfrfac�(tT a cittiil'dt1 system is used grounding is achieved with the UniRac UGC -2 grounding clips the module frame. Table 3 defines mounting options, attachment locations and large systems, wet the modules with the cleaning solution, letP.m stand for fiv resultin load colon achieved for each module configuration. The module is only UL Listed for use when its facto frame is full Intact. Do not minutes, and then rinse them wi 1R rAs OPPORTUNITY SPRI- Fremont in combination with UniRac's Mid or End clamps and Sliders with a 1/4-20 B g g y y gti� li a yPr or a s `sply egee. ��r bolt and flanged nut torqued to 120 in -lbs. remove or alter the module frame, and do not create additional mounting holes not use harsh industrial -strength cleaning materials such as scouring powder, ` g q because doing so may compromise the integrity of the frame, steel wool, scrapers, blades, or other sharp instruments to clean the module PROJECT D-0051671 Note: Method 5 was evaluated to UL 2703 by TUV. As such, the use of these glass. Use of such materials will void the product warranty. devices is not considered part of the UL Listing of these modules. , Modules may be mounted using the following methods only: DATE DRAWN 04-20-2016 - YY is a number rangirig from 18 to 24 and ZZZ is panel wattage. DRAWN BY HLLUVIOSO 0 2015 SunPower Curpuration. All rights reserved. Specifications Included in this manual are subject W change without notice. Page 13 0 zols sunPmver corporation. All rights reserved. Speciricatium included in this manualare subject W change wilhuut notice. Page 14 DATE CHECKED 04-20-2016 CHECKED BY. APATEL SHEET . FIGURE A: MODULE INSTALLATION MANUAL PAGE 3 FIGURE B: MODULE INSTALLATION MANUAL PAGE 4 SOLAR -E8 n i -- - = J tt IL U b� 0.RESIDENTIAL G3 FRAME ONLY 72 CELL MODULE FRAME DETAIL. 96 CELL MODULE FRAME DETAIL. • SIDE FRAME PROFILE . Axfld.61*tn " '708 [31-.41nl - „ 4z p4.8mm .. 1046mm [41.2in] J0.19in] _ �� 75dmm (29.2in]-�� J0.19in]' .1002mnr [39.4in] 41 Droll) Hoes' • Dram 1-1.6 7 17X O d.6m.m 12X O "6.6rr7in . 2611-1) (0.26in) s Abunlino Holes ♦ ♦ I )Jwunling HcJes I InTall Residential - C9 E E.. E E . I OX'0.1.21um' E MOduleS (O.1Tinj� h g.M FAI 1OX04.2mm a �:� ENDFRAMEPROFILE ,6=1 How 17 Ground Holes - "[6OCk V�) ' ' Ali Bock Vl�y r r 46m n [Front View) [1.8ir ]Front Viow► .. L .. d6nun Method 1:. _ -t'- . ,. .. - 11.2ild ♦ FrameH.ok umr,>. luta - Locations " lannl RESIDENTIAL t ONLY •COMPATIBLE FRAME) 72 CELL MODULE.(NO MOUNTING HOLES) 96 CELL MODULE (NO MOUNTING HOLES) SIDE FRAME PROFILE lei . .Cb 1056mm _ Lar T [31.57JnJ-14i.Ieo-J - 1 v1�7 f - xUP 1 .. J(IJai.: Residential F E Modules END FRAME PROFILE � - laalorm• '77 .. . Ax .0% (', oDanm FOR • s •ME) MODULES ONLY, s PINS 96 CELL COMMERCIAL MODULE, " 128 CELL COMMERCIAL MODULE" SIDE FRAME. PROFILE ' nvn 10461I1m [41.ZInl 1046mm[412in lwa°n 4x 04.8 ,wmarlsv.e�] J.Irmn I•4Inl 10.191n] 1D02mm [39.4i4� .pii7mm(sm - I•lJaf . Drain Holes 12X06.61tun' - urtraomm[.r7F � (0.261p] f- ...5 crouna nage ♦ I*- [15.7ini oultingHoles: f �BX0-0.2111111 � _ `°, v�NsuninB bakea017inj mCommercial .[•E' E -E E Ilan] Gluuad Hui E E E .E With Stacking.Pins Modules in v N4X66.10mm Omar-rapEND FRAME PROFILE. Baek YltaxkvieStacWng Pins L .(Frontviev)" t Ir,da �1PA1 3.2mm 10.131n]L LnW ~ U oW. U V mLn o}�L0g F.T.hl O U a toco INPOWER SUNPOWER CORPORATION Z a W 9 V v: oOZ Safety and Ins allatiorIns Ction's Document 0 1-14158 Rev S t tru - 0 Cl. N W P 4t Module Frame Detail .....' a � a �' s n i -- - = J tt IL U b� 0.RESIDENTIAL G3 FRAME ONLY 72 CELL MODULE FRAME DETAIL. 96 CELL MODULE FRAME DETAIL. • SIDE FRAME PROFILE . Axfld.61*tn " '708 [31-.41nl - „ 4z p4.8mm .. 1046mm [41.2in] J0.19in] _ �� 75dmm (29.2in]-�� J0.19in]' .1002mnr [39.4in] 41 Droll) Hoes' • Dram 1-1.6 7 17X O d.6m.m 12X O "6.6rr7in . 2611-1) (0.26in) s Abunlino Holes ♦ ♦ I )Jwunling HcJes I InTall Residential - C9 E E.. E E . I OX'0.1.21um' E MOduleS (O.1Tinj� h g.M FAI 1OX04.2mm a �:� ENDFRAMEPROFILE ,6=1 How 17 Ground Holes - "[6OCk V�) ' ' Ali Bock Vl�y r r 46m n [Front View) [1.8ir ]Front Viow► .. L .. d6nun Method 1:. _ -t'- . ,. .. - 11.2ild ♦ FrameH.ok umr,>. luta - Locations " lannl RESIDENTIAL t ONLY •COMPATIBLE FRAME) 72 CELL MODULE.(NO MOUNTING HOLES) 96 CELL MODULE (NO MOUNTING HOLES) SIDE FRAME PROFILE lei . .Cb 1056mm _ Lar T [31.57JnJ-14i.Ieo-J - 1 v1�7 f - xUP 1 .. J(IJai.: Residential F E Modules END FRAME PROFILE � - laalorm• '77 .. . Ax .0% (', oDanm FOR • s •ME) MODULES ONLY, s PINS 96 CELL COMMERCIAL MODULE, " 128 CELL COMMERCIAL MODULE" SIDE FRAME. PROFILE ' nvn 10461I1m [41.ZInl 1046mm[412in lwa°n 4x 04.8 ,wmarlsv.e�] J.Irmn I•4Inl 10.191n] 1D02mm [39.4i4� .pii7mm(sm - I•lJaf . Drain Holes 12X06.61tun' - urtraomm[.r7F � (0.261p] f- ...5 crouna nage ♦ I*- [15.7ini oultingHoles: f �BX0-0.2111111 � _ `°, v�NsuninB bakea017inj mCommercial .[•E' E -E E Ilan] Gluuad Hui E E E .E With Stacking.Pins Modules in v N4X66.10mm Omar-rapEND FRAME PROFILE. Baek YltaxkvieStacWng Pins L .(Frontviev)" t Ir,da �1PA1 3.2mm 10.131n]L . - DATE DRAWN 04-20-2016 DRAWN BY HI:LUVIOSO 0 2015 SunPusver Corporation. All rishls reierved. Specificelions Included in this manual are subject to change without notice. Page)- - DATE CHECKED 04-20-2b16 .. .i x _ CHECKED BY.. APATEL ,�. .. .. .. _ .. .. .. - SHEET .. FIGURE A: MODULE INSTALLATION MANUAL, PAGE 5 ~ U O U a W Ln Z Ln O'; ` y ` rn U rai O WU N a Z F O = Ln O M O' o 0 V LU oC �. W. H C:, O H C7. W a t0 _ W Ln En Z .. .. O CUE��ri`IN tl�'a I SLAdinig.1 w b , Dep rtnenjIx °;. N APR 2. af?09!1 w REVIEWED FOR Com DE COMPLIANCE. OPPORTUNITY SPRr- Fremont " Reviewed By. �,nj �� PROJECT D-0051671 . . - DATE DRAWN 04-20-2016 DRAWN BY HI:LUVIOSO 0 2015 SunPusver Corporation. All rishls reierved. Specificelions Included in this manual are subject to change without notice. Page)- - DATE CHECKED 04-20-2b16 .. .i x _ CHECKED BY.. APATEL ,�. .. .. .. _ .. .. .. - SHEET .. FIGURE A: MODULE INSTALLATION MANUAL, PAGE 5 1fi1-„'Jt” i. �•.+a ASA®AIMVNo" bapertile Uu SPR 2 2016 lyl LAMIM OPPORTUNITY SPRI- Fremont R.Q�vi �i .. .. PROJECT D-0051671. DATE DRAWN, 04-20-2016 - - DRAWN BY : �HLLUViO5O -qZ DATE CHECKED 04-20-2016 " CHECKED BY APATEL ' 13 SCALE . 3/16tI _ 11 ' - OSI. - '', .. .. 21 O _ _ SHEET .. - . ..,�$p SOLAR -E10