Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
15080028
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: 15080028 749 RAINBOW DR CUPERTINO CA 95014 (362 30 013) CHUEN YANG YANG 15215 GALT ST SAN LEANDRO 07ER'S NAME: PILLAI SANTHOSH N AND THAMPI CHITRA DATE ISSUED: 09/24/2015 O R'S PHONE: (408) 368-6557 PHONE NO: None CONTRACTOR'SDECLARATION BUILDING PERMIT INFO: UcE rise Class $ 'Lic. #897965 Cor tractor CHUEN YANG YANG Date 06/30/2016 BLDG —ELECT _ PLUMB I he eby affirm that I am licensed under the provisions of Chapter 9 (commencing. _ MECH _ RESIDENTIAL _ COMMERCIAL witl Section 7000) of Division 3 of the Business & Professions Code and that my licei ise is in full force and effect, JOB DESCRIPTION: CONVERT GARAGE (501 S.F.) & ADD 446 S.F. TO CREATE I he eby affirm under penalty of perjury one of the following two declarations: (1) MASTER BDRM, 4TH BDRM & LIVING RM. REMODEL 2 1. I have and will maintain a certificate of consent to self -insure for Worker's (E) BATHS (122 S.F.) & RECONFIGURE/REMODEL OTHER Compensation, as provided for by Section 3700 of the Labor Code, for the 311 S.F. REPLACE WATER HEATER W/TANKLESS & performance of the work for which this permit is issued. RELOCATE/REPLACE (E) FURNACE 2. I have and will maintain Worker's Compensation Insurance, as provided for by +1� REV #1 REMOVE STONEWORK AT EXTERIOR FROM SCOPE OF Section 3700 of the Labor Code, for the performance of the work for which this WORK ISSUED 11/28/2016 permit is issued. Sq. Ft Floor Area: Valuation: $200000.00 l/ APPLICANT CERTIFICATION I ce tify that I have read this application and state that the above APN Number: Occupancy Type: info mation is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize 362 30 013 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED ma accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point WITHIN 180 DAYS OF PERMIT ISSUANCE OR source regulation per the Cupertino Municipal Code, Section 9.18. 180 DAYS FROM. LAST CALLED INSPECTION. Sig ture 1AIL, Date 11/28/2016 Issued by: Leeacv affirm that I am exempt from the Contractor's License Law for one of the Date: 09/24/2015 I hereby RE -ROOFS: follc wing two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is 1. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed Signature of Applicant: ,contractors to construct the project(Scc.7044, Business & Professions Code). Date: 11/28/2016 I he -eby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code; for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(a) should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally, should I use equipment or devices which emit hazardous Worker's Compensation laws of California. If, after making this certificate of air contaminants as defined by the Bay Area Air Quality Management District I exemption, I become subject to the Worker's Compensation provisions of the will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and Labor Code, I must forthwith comply with such provisions or this permit shall the Health & Safety Code, Sections 25505, 25533, and 25534. be deemed revoked. Owner or authorised age rit:–" / APPLICANT CERTIFICATION Date: 11/28/2016 ce ify that I have read this application and state that the above information is CONSTRUCTION N corr 3ct. I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agenc for the performance rela ing to building construction, and hereby authorize representatives of this city of work's for which this permit is issued (Sec. 3097, Civ C.) toe iter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to si ive indemnify and keep harmless the City of Cupertino against liabilities, judE ments; costs, and expenses which may accrue against said City in Lender's Address con equence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Coc e, Section 9.18. 1 understand my plans shall be used as public records. Signature Date 11/28/2016 Licensed Professional CONSTRUCTION PERMIT APPLICATION, COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(a)_cupertino.org UPERTINO ION NEW CONSTRUCTION ❑ ADDITION ❑ALTERATION / TI REVISFERRED ORIGINAL PERMIT # P OJECT ADDRESS t -1APN Q APN # O ERNAMEPHONE E-MAIL I A r d�1'` Q IcaCss �+s l S1 REET ADDRESS CITY, STATE, ZIP I FAX INTACT NAME LAIALA `10A , ' PHO 3(0 213 y E-MAIL TYPE #STORIES REET ADDRESS -r TYPE (jAy� SQ.FT. CITY, STATE, G E, ISTG OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTORAGENT Fal. ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT INTRACTOR NAMr - O v LICENSE NUMBE>J a 0%` LICENSE TYPE c BUS. LIC j )MPANY NAME/1 NET AREA r E-MAIL i FAX REET ADDRESS , j (' KITCHEN OTHER CITY, STATE; ZIP -,f w PHONVc> t :CHITECVENGINEER NAME 1 \ REMODEL AREA LICENSE NUMBER ^ Ci. REMODEL AREA BUS. LIC # )MPANYNAME. IQ C. ..E-MAILFAX RCH AREA DECK AREA TOTAL DECKIFORCH AREA REET ADDRESS CITY, STATE, ZIP PHONE 1 . o c? 455- 3_7 F SCRIPTION OF WORK 2 L,-,,4a c V aa _,--n e) BldgApp_2011,doc revised 06121111 E ISTING USE. PROPOSED USE- CONSTR TYPE #STORIES USE TYPE OCC. SQ.FT. VALUATION ($) E, ISTG NEW FLOOR DEMO TOTAL, A$ZEA AREA AREA NET AREA . BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA P RCH AREA DECK AREA TOTAL DECKIFORCH AREA GARAGE AREA: DETACH []ATTACH # WELLING UNITS: ISA SECOND UNIT ❑YES SECOND STORY ❑YES BEING ADDED? ❑ NO ADDITION? []NO , P4 P -APPLICATION ❑ YES IF YES, PROVIDE COPY OF kNNINGAPPL# ❑NO PLANNING APPROVAL LETTER IS THE BLDG AN ❑ YES EICHLER HOME? []NO : " TOTAL VALUATION: By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the roperty owner's behalf. I have read this a plication and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I -agree to comply with all applicable local ordinances and state laws relating to building cons la orize representatives of Cupertino to enter the above-i/dentifiedroperty for inspection purposes. Signature of Applicant/Agent: _ Date: / y SUPPLEMENTAL INFORMATION REQUIRED PLANHECI TYPE <'r. ROUTING siir ❑ ovERTxE couNZEx D Bu rDztvGPIANREVLEw z New SFD or Multifamily dwellings: Apply for demolition permit for C isting building(s). Demolition permit is required prior to issuance Of building permit for new building. ❑ xPz Ss ❑ P ASNINGPLAN REVIEw �. Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ ST RD ❑ P Bi IC wrzizxs rm if any Hazardous Materials are being used as part of this project.' y ❑' LARGfs" ❑ FIRE DEPT Copy of Planning Approval Letter or Meeting with Planning prior to MAJOR ❑ SANITARYSEwERDISTRICT " S bmittalOfBuildingPermitapplication. BldgApp_2011,doc revised 06121111 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 7497 RAINBOW DR CONTRACTOR: CHUEN YANG YANG PERMIT NO: 15080028 CONSTRUCTION CO OWNER'S NAME: PILLAI SANTHOSH N AND THAMPI CMTRA 15215 GALT ST DATE ISSUED: 09/24/2015 OWNER'S PHONE: 4083686557 SAN LEANDRO, CA 94579 PHONE NO: (510) 213-9981 LICENSED CONTRA OR' S D CL RATION JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL ❑ License Class CONVERT GARAGE (501 S.F.) & ADD 446 S.F. TO CREATE Lic. # (N) MASTER BDRM, 4TH BDRM & LIVING RM. REMODEL 2 (E) BATHS (122 S.F.) & RECONFIGURE/REMODEL OTHER Contracto i Date I hereby affirm that I a licen ed nder a provisions of Chapter 9 (commencing with Section 7000) of Divisi6n 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: Sq. Ft Floor Area: Valuation: $200000 �. I have and will maintain a certificate of consent to self -insure for Worker's as provided for by Section 3700 of the Labor Code, for the pompensation, Ierformance of the work for which this permit is issued. have and will APN Number: 36230013.00 Occupancy Type: maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this Permit is issued. APPLICANT CERTIFICATION PERMIT EXPIRES IF WORK IS NOT STARTED I certify that I have read this application and state that the above information is WITHIN 180 DAYOF-PE_IIT ISSUANCE OR correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives ,R-AT rl INSPECTION. of this city to ent upon the above mentioned property for inspection purposes. (We) agree ave indemnify and keep harmless the City of Cupertino --1 �r against liabilities, ju costs, and Iss e - - Date: a expenses which may accrue against said City in consequence of the granting of this permit. Additional) , the applicant understands and will comply with all non -point source regulati per t Cupertino Municipal Code, Section 9.18. Signature Datel, d RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ® OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER a. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) HAZARDOUS MATERIALS DISCLOSURE 2: I, as owner of the property, am exclusively contracting with licensed contractors to I have read the hazardous materials requirements under Chapter 6.95 of the construct the project (Sec.7044, Business & Professions Code). California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & I hereby affirm under penalty of perjury one of the following three declarations: Safety Code, Section 25532(a) should I store or handle hazardous material. t I have and will maintain a Certificate of Consent to self -insure for Worker's Additionally, should I use equipment or devices which emit hazardous air Compensation, as provided for by Section 3700 of the Labor Code, for the contaminants as defined by the Bay Area Air Quality Management District I will performance of the work for which this permit. is issued. maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the 2. I have and will maintain Worker's Compensation Insurance, as provided for by Health & Safety Code, Sections 25505, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this Owner or a �a. permit is issued. Date. 3. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I I hereby affirm that there is a construction lending agency for the performance of work's must forthwith comply with such provisions or this permit shall be deemed for which this permit is issued (Sec. 3097, Civ C.) Lender's Name revoked. Lender's Address APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is ARCHITECT'S DECLARATION correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter I understand my plans shall be used as public records. upon the above mentioned property for inspection purposes. (We) agree to save Licensed Professional indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date CUPERTINO� ❑ NEW CONSTRUCTI'Mr CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 7�77-3228 • FAX (408) 777-3333 = building CabcupErtino orq/ S-�� �i�/j� ii 11AI e 7��m -nor ffo I� r' -'t d (f Q u r�i�icr;llvly/ II LJ H.EVISION/DEFERRED ORIGINAL PERMIT PROJECT ADDRESS d { 74 11-( dv t #✓ti� a I APN R K� ORrERNAIYM f4Vtt 14E-MSiL 1721 PHONE J`�1�'3(,� STREET ADDRESS L Oryx s CITY, STATE, ZIP I FAX "z / K • i Alla p2 -o a Pp, T� CONTACT NAME 15 �rri t4(L.Kg ,�C�� PHONE /' G. I E-MAIL C71 I � ! V ` i LIG I "1 ?J !9 � �: • STREET ADDRESS p 2�t I Ir— CITY, Y, STATE, ZIP y� C"`C�i C7 r7t CLL fPVCY7 L' `si v "ilii'�ne FAX o"r-P OWNER -BUILDER ❑ OVNERAGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT i'ARCHITECT ❑ ENGIN ER - El DEVELOPER ❑ Tt?iAlv'T CONTRACTOR NA1�IE j P /1 ' LICENSE I LTIBER I LICENSE TYPE BUS. LIC, COI✓,PANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE ARCIM-ECT/ENGINEER NAME r i ft ltK l LICENSE NUMBER (� (( BUS. LIC R COMiPANY N'AI,Td �1 • v f' FAX �— STREET ADDRESS CITY, STATE: ZIP F PHONE C y DESCRIPTION OF WORK Ne�'J 6we 561 �;' OF, C71 d (V) VC74 a o1 rioff' Olt" EXISTDQGUSE PROPOSED USE I CONSTRTYPE -I rSTO7S 1 luow;e 4, 115F F USE I TYPE I OCC. I SQ.FT. VALUATION (SfA EXISTG NEW FLOOR] 6DET40 TOTAL `Z�� - AREA d AREA'C AREA - NET AREA I I BAT 00. KrrCHE.N REMODEL AREA BZ_� REMODELAREA OTHER/ REMODEL AREA / - PORCH AREA DECK AREA T TALDECKIPORCHP.REA GARAGE AREA: ACH- - �� .�J 9DWELLINGUNITS: ISASECONDUNIF U1r.S I SECONDSTORY []YES - — BEING ADDED?0 I ADDITION? IS'13C�p{6 PRE -APPLICATION --`ES ri1cS,PROVID$COPYOF I ISTHEBLDGAN ❑1 E? t�. -, OT.iLVALUATIO�N9: PLAN'NINGAPPLn E)NO PLANNING APPROVAL LEETTER EICHLERHOMh`8' . � Y By my signature below, I certify to each of the following: I am the property owner or authonze _ t to act on the proper y ovmer's behalf. I have read this application and the information I have provided is correct, I have read the Description of t3'Ork and verify it is accurate. I aeree to comply;vith ali applicable Iocal ordinances and state laws relating to building construction. I authorize representatives to enter the above-identined propel for inspection purposes. S ignature of Applicant/Agent: Date: SUPPLEMENTAL Ii�IFORivIATION QUIREDIM - - New SFD or Multifamily d -Wellings: Apply for demolition permit forxR building(s). �= q� � f. M VIOM OBER THE COUItTER existing Demolition permit is required prior to issuance of buIIdIIIg HIM 10-0- MEN permit for new building. _- Excess I�Pisq�I;�p�A?� ISE _ Commercial BIdgs: Provide a completed Hazardous Materials Disclosure =© cTnDSRD^ z flBI_c�oltTts' 07 form if any Hazardous Materials are being used as part of this project. # — Copy of PIanniner Approval Letter or Meeting With Planning prior to submittal of Building Permit application. �= � �?�R � h�� ��sx;s.�- RsE�;�RDIs�,ItIC�• - " Bldg-Ap.p2011.doc revised 06121/11 CITY OF CUPERTINO FEE ESTIMATOR BUILDING DIVISION ADDRESS: 7497 RAINBOW DR DATE: 08/04/2015 REVIEWED BY: MELISSA APN: 362 30 013 :2nd VALUATION:$200,000 _PERMIT TYPE: Building Permit PLAN CHECK TYPE:pgIMARY Addition USE: SFD or Duplex Unit? Yes •r No PENTAIVIATION TC? Yes PERMIT TYPE: 1R3SFDADD WORK CONVERT GARAGE 501 S.F. & ADD 446 S.F. TO CREATE N MASTER BDRM 4TH BDRM & , SCOPE LIVING RM. REMODEL 2 (E) BATHS (122 S.F.) & RECONFIGURE/REMODEL OTHER 311 S.F. ru OCCUPANCY TYPE: TYPE OF FLR AREA CONSTR. s,£ PC FEES PC FEE ID BP FEES BP FEE ID R-3 (Custom) II-B,III-B,IV,V-B 1,442 $2,757.15 IR3PLNCK $2,035.55 IR3INSP TOTALS: I 1,442 $2,757.15 I $2,035.55 Mech. Plan Check 0.0 hrs $0.00 Plumb. Plan Check .0 hrs $0.00 1>1cac. t'lczrt C:'lu i Mech. Permit Fee: IMPERMIT Plumb. Plrmit Fee: IPPERMIT I'lec. Perini! rurt 1'sez: Other Mech. Insp. 0.0 hrs $48.00 Other Plumb Insp. Q.0 hrs $48.00 Cit?re• lilec. trtsrn. :l[, c/r. hn,n. Fee: 1'Izrrnls. Inrt7, I iec. Msp. I ee: NOTE: This estimate does not include fees due to other Departments ('. e. Planning, Public Works, Fire, Sanitary Sewer District, School I)Z.Q/PZCf_ vtr. 1 Tleace f no ,..,, x,...,.a __ o. _ __ :____ ._. - ,. .. __ _ _ _ • �..„«,.u. FEE ITEMS Fee Resolution 11-053 E.'7/LQ � u It"t— uVaaume FEE anu are QTY/FEE ont an esumate. Contact the De t or addn'l info. MISC ITEMS Plan Check Fee: $2,757.15 122 s.f. Remodel, Bath (<=300 sf) $645.00 1REMRESBAT Suppl. PC Fee: (j)Reg. 0 OT 0.0 hrs $0.00 PME Plan Check: $0.00. 311 s.f. Remodel, Other $503.00 1 1REMRES07'H Permit Feer $2,035.55 Suppl. Insp. Fee-IS Reg. OT 0.0 hrs $0.00 1 # Plumbing $29.00 IPRWHEATR Water Heater PME Unit Fee: $0.00 PME Permit Fee: $96.00 # Mechanical $143.00 Furnace, Forced -Air C ons1r°uction Tax:IMFR=<100 _4dininisirativ i`'ee: 0 Work Without Permit? 0 Yes Q) No $0.00 Advanced Planning Fee: IPLLONGR $201.88 Select a Non -Residential Building or Structure e Travel Documentation Fee: ITRAVDOC $48.00 Strong Motion Fee: 1BSEISMICR $26.00 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $8.00 SUBTOTALS: ' $5,172.58 $1,320.00 TOTALT'EE 4`,' $6,492.58 Revised: 07/02/2015 BUILDING ENERGY ANALYSIS REPORT PROJECT: Rainbow Drive Addition 7497 Rainbow Drive Cupertino, CA 95014 Project Designer: Aditi Mukherjee - Architect 1448 S. Stelling Road;.;.;. Cupertino, CA (408) 333-9363 CCPERTINO 80ding Deperbpent SEP 2 3 2015 REVIEWED FUR DUDE COMPLIANCE Report Prepared by: Keviewea By_ Jennifer Ferris ACCURATE ENERGY 3713 Laguna Way Sacramento, CA 95864 (;Or 916 483-7313 Job Number: 215156 SUBMITTAL Date: 8/3/2015 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. IThis program developed by EnergySoft, LLC — www.energysoft.com. Ener Pro 6.6 by Ener Soft User Number: 3119 ID: 215156 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the cmmnliance annroach used. Ezcentinns may annly_ Review the resnective code section for more information. Building Envelope Measures: § 110.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of § 10-111(a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. §110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CFIR. §110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. § 150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. § 150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). §150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior § 150.0(g)1: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II § 150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of § 150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8( ). § 150.0 (q)' Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e) I B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §I50.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 110.0-§ 110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. § 150.0(h)1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §150.0(h)2. §150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). § 150.00) IA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.0(j)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the fust 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § 150.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 2613 Low -Rise Residential Mandatory Measures Summary § 150.00)2C: Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § 150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150.00)3B: or Class H vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class H vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)l: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints §150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labelmi . § 150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be § 150.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of § 150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The § 150.0(m)13: space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §I50.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2013 Low -Rise Residential Mandatory Measures Summary § 110.4(b)1: Any Pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - ammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § 150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §150.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §150.0(k)1B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k)1C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)1D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no § 150.0(k) lE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §150.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it §150.0(k)2H: functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. § 150.0(k)21: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § 150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. § 150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing §150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § 150.0(k)9B: following requirements: i. Shall comply with § 150.0(k)9A; or ii. Shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. § 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. §150.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9, § 130.0, § 130. 1, § 130.4, § 140.6, and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § 150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §150.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a §110.10(a)l: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10(b) through §1 10.10(e). § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(bA For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit §110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. §110. WWI: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric'. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Rainbow Drive Addition Date 8/3/2015 System Name HVAC Floor Area 2,207 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 636 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 55,000 19,300 1,240 373 19,687 Total Output (Btuh) 55,000 0 Output (Btuh/s ft) 24.9 875 1,093 Cooling System 0 0 Output per System 36,000 0 0 0 0 Total Output (Btuh) 36,000 0 1,240 0 Total Output (Tons) 3.0 875 1,093 Total Output (Btuh/sqft) 16.3 Total Output (s ft/Ton) 735.7 1 21,051 r 21,873 Air System CFM per System 1,000 HVAC EQUIPMENT SELECTION Airflow (cfm) 1,000 Split Furnace & Air Conditioner 32,118 0 55,000 Airflow (cfm/s ft) 0.45 Airflow (cfm/Ton) 333.3 Outside Air (%) 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 32,118 0 55,000 Jan 1 AM Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 28 OF Outside Air 0 cfm 67 IF 4 67 OF 118 °F 118-F = Heating Coil Supply Fan 117 OF 1,000 cfm ROOM 68 IF A 4 COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 88/68°F Outside Air 0 cfm 76 / 58 OF 76/57°F 46/44°F 46/44°F f � J C Cooling Coil Supply Fan 1,000 cfm 32.4% 47 / 45 OF ROOM 75 / 57 OF EnergyPro 6.6 by EnergySoft User Number: 3119 RunCode: 2015-08-03716:25:39 ID: 215156 Page 6 of 6 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Rainbow Drive Addition Calculation Date/Time: 16:30, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: 215156final.ribd CF1 R -PRF -01 Page 1 of 11 GENERAL INFORMATION 01 01 Project Name Rainbow Drive Addition 02 This building incorporates features that require field testing and/or vl�ific 'ce a= 02 Calculation Description Title 24 Analysis This building incorporates one or more Special Features shown ielo f-; 03 Project Location 7497 Rainbow Drive C pliance Margin MW 04 City Cupertino 05 Standards Version Compliance 2015 06 Zip Code 95014 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ4 09 Software Version CBECC-Res 2013-4 (744) 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 180 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 2207 15 Number of Zones 2 16 Slab Area (ft2) 0 17 Number of Stories 1 18 Addition Cond. Floor Area 947 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 0 21 Glazing Percentage (%) 18.9% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or vl�ific 'ce a= fied HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown ielo f-; c r Propo —d ign f. r %JvulVll 1 #1 IAL Registration Number: 215-A0214591A-000000000-0000 Registration Date/Time: 2015-08-0322:00:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:31:10 EN€RG7USE SUMMARY 04 05 - 'MI6 07 08 Energy Use (kTDV/ft2 yr) Standard Design r Propo —d ign f. C pliance Margin , rcent Improvement Space Heating 17.37 Z C166 ' 0.77 4.4% Space Cooling 8.90 "G 12.1 -4.29 8.2% IAQ Ventilation 0.00 > .4,Qz 0.00 0.0% Water Heating 13.10 FR 3.83 29.2% Photovoltaic Offset ---- 0.00 0.00 Compliance Energy Total 39.37 39.06 0.31 0.8% %JvulVll 1 #1 IAL Registration Number: 215-A0214591A-000000000-0000 Registration Date/Time: 2015-08-0322:00:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:31:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Rainbow Drive Addition Calculation Date/Time: 16:30, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: 215156final.ribd REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. Cathedral Ceiling HERS FEATURE SUMMARY CF1 R -PRF -01 Page 2 of 11 The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • --None -- Cooling System Verifications: • Minimum Airflow • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • --None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)' 82.81 82.50 0.31 0.4% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Rainbow Drive Addition 2207 1 4 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Existing Conditioned HVAC1 1260 8 DHW Sys 1 Addition Conditioned HVAC1 947 8 DHW Sys 1 Registration Number: 215-Ao214591A-000000000-0000 Registration Date/Time: 2015-08-0322:00:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-07082015-744 Report Generated at: 2015-08-03 16:31:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Rainbow Drive Addition Calculation Date/Time: 16:30, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: 215156final.ribd CF1 R -PRF -01 Page 3 of 11 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft2) Tilt (deg) Status Verified Existing Condition Front Existing Wall 11 180 Front 32 90 Existing No Left Existing Wall 11 270 Left 223 40 90 Existing No Back Existing Wall 11 0 Back 245.6 81.4 90 Existing No Right Existing Wall 11 90 Right 223.4 20 90 Existing No Attic 2 Existing R-30 Attic 0.33 18.43 1231.8 0.85 0.07 Existing No Raised Floor Existing R-19 Floor Crawlspace 1260 Existing No Front 2 Addition R-13 Wall 180 Front 184.6 93 90 New N/A Left 2 Addition R-13 Wall 270 Left 148.6 16 90 New N/A Back 2 Addition R-13 Wall 0 Back 138.7 45 90 New N/A Right 2 Addition R-13 Wall 90 Right 325 89.1 90 New N/A Interior Surface 2 Addition»_Garage_ R-13 Wall Demising 323 17.8 New N/A Roof 2 Addition R-30 Attic RB 942.7 New N/A Raised Floor 2 Addition R-19 Floor Crawlspace 947 New N/A Front 3 _Garage_ Exterior Garage Wall 180 Front 112.1 112 90 New N/A Front 4 _Garage_ Exterior Garage Wall 180 Front 54.6 90 New N/A Left 3 _Garage_ Exterior Garage Wall 270 Left 180.3 17.8 90 New N/A Right 3 _Garage_ Exterior Garage Wall 90 Right 24 90 New N/A Attic 3 _Garage_ R-0 Roof Attic Garage 448 New N/A OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 11 12 13 Roof Framin Verified Orientatio Area Skylight Roof Rise Roof Roof Reflectan Roof g Statu Existing Name Zone Type n (ft2) Area (ft2) (x in 12) Pitch Tilt(deg) ce Emittance Factor s Condifion Attic Existing R-30 Attic at Front 28.3 5.8 4 0.33 18.43 0.1 0.85 0.07 Existin No Skylight 9 Roof Addition R-30 Attic RB at Skylight Back 4.4 4.3 0 0 0 0.1 0.85 0.07 New N/A Registration Number: 215-A0214591A-000000000-0000 Registration Date/Time: 2015-08-03 22:00:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF113-07082015-744 Report Generated at: 2015-08-03 16:31:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Rainbow Drive Addition Calculation Date/Time: 16:30, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: 215156final.ribd CF1 R -PRF -01 Page 4 of 11 ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Statu s Verified Existing Condition Attic Garage Attic Garage Roof Cons Ventilated 4 0.1 0.85 Yes No New No Attic Existing Attic Roof Existing Ventilated 4 0.1 0.85 No No Engisti No Attic Addition Attic Roof Addition Ventilated 1 0 1 0.1 0.85 Yes No New No CaICERTS, iril... HER 5 PROVIDER Registration Number: 215-A0214591A-000000000-0000 Registration Date/Time: 2015-08-03 22:00:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:31:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Rainbow Drive Addition Calculation Date/Time: 16:30, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: 215156final.ribd CF1 R -PRF -01 Page 5 of 11 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Multiplie Height (ft) r Area (ft2) U -factor SHGC Exterior Shading Status Verified Existing Condition New W2 2640 CS Left (Left -270) ---- ---- 1 10.0 0.32 0.25 Insect Screen (default) New N/A New W3 2640 CS Left (Left -270) ---- ---- 1 10.0 0.32 0.25 Insect Screen (default) New N/A New W4 5040 HS Left (Left -270) ---- ---- 1 20.0 0.32 0.25 Insect Screen (default) New N/A ALT 51132 to W5 2040 CS Back (Back -0) ---- ---- 1 8.0 0.32 0.25 Insect Screen (default) Altered N/A ALT 51132 to W9 5040 HS Back (Back -0) ---- ---- 1 20.0 0.32 0.25 Insect Screen (default) Altered N/A ALT 8068 to 8068 SGD Back (Back -0) ---- ---- 1 53.4 0.32 0.25 Insect Screen (default) Altered N/A EX 5040 XO Right (Right -90) ---- ---- 1 20.0 0.58 0.65 Insect Screen (default) Existing No New S1 22x38 Attic (Front -180) ---- ---- 1 5.8 0.43 0.28 None New N/A New S2 14 SunTunnel Attic (Front -180) ---- ---- 1 1.1 0.55 0.30 None New N/A New S4 22x28 Attic (Front -180) ---- ---- 1 4.3 0.43 0.28 None New N/A New S5 14 SunTunnel Attic (Front -180) ---- ---- 1 1.1 0.55 0.30 None New N/A New S6 22x28 Attic (Front -180) ---- ---- 1 4.3 0.43 0.28 None New N/A New S7 22x38 Attic (Front -180) ---- ---- 1 5.8 0.43 0.28 None New N/A New S8 22x38 Attic (Front -180) ---- ---- 1 5.8 0.43 0.28 None New N/A New W6 8060 CS/FX Front 2 (Front -180) ---- ---- 1 48.0 0.32 0.25 Insect Screen (default) New N/A New D1 6076 FD Front 2 (Front -180) ---- ---- 1 45.0 0.32 0.25 Insect Screen (default) New N/A New W6 2040 CS Left 2 (Left -270) ---- ---- 1 8.0 0.32 0.25 Insect Screen (default) New N/A New W7 2040 CS Left 2 (Left -270) ---- ---- 1 8.0 0.32 0.25 Insect Screen (default) New N/A New W8 7660 CS/FX Back 2 (Back -0) ---- ---- 1 45.0 0.32 0.25 Insect Screen (default) New N/A New D3 6068 SGD Right 2 (Right -90) ---- ---- 1 40.0 0.32 0.25 Insect Screen (default) New N/A New W11 5046 HS Right 2 (Right -90) ---- ---- 1 22.5 0.32 0.25 Insect Screen (default) New N/A New W12 2050 CS Right 2 (Right -90) ---- ---- 1 10.0 0.32 0.25 Insect Screen (default) New N/A New W13 2018 FX Right 2 (Right -90) ---- ---- 1 3.3 0.32 0.25 Insect Screen (default) New N/A New W14 2050 CS Right 2 (Right -90) ---- ---- 1 10.0 0.32 0.25 Insect Screen (default) New N/A New W15 2018 FX Right 2 (Right -90) 1 3.3 0.32 0.25 Insect Screen (default) New N/A New S3 22x28 Roof(Back 1 4.3 0.43 0.28 None New N/A Registration Number: 215-A0214591A-000000000-0000 Registration Date/Time: 2015-08-03 22:00:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:31:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Rainbow Drive Addition Calculation Date/Time: 16:30, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: 215156final.ribd CF1 R -PRF -01 Page 6 of 11 DOORS 01 02 03 04 05 06 Name Side of Building Area (ft2) U -factor Status Verified Existing Condition 2868 Door Interior Surface 2 17.8 0.50 New No CaICERT'c,,HERS PROVIDER DE R Registration Number: 215-Ao214591A-000000000-0000 Registration Date/Time: 2015-08-03 22:00:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:31:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Rainbow Drive Addition Calculation Date/Time: 16:30, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: 215156final.ribd CF1 R -PRF -01 Page 7 of 11 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers • Inside Finish: Gypsum Board • Cavity/ Frame: no insul. /2x4 • Exterior Finish: Wood Exterior Garage Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.302 Siding/sheathing/decking Ceilings (below • Inside Finish: Gypsum Board R-0 Roof Attic Garage attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.481 • Cavity/ Frame: no insul. /2x4 • Cavity/ Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 • Roof Deck: Wood Siding/sheathing/decking Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 • Roofing: Light Roof (Asphalt Shingle) • Cavity/ Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 • Roof Deck: Wood Siding/sheathing/decking Attic Roof Existing Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 • Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/ Frame: R-11 /2x4 • Exterior Finish: Wood Wall 11 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 11 0.103 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below • Cavity/Frame: R-9.1 /2x4 R-30 Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 30 0.032 • Over Floor Joists: R-20.9 insul. • Inside Finish: Gypsum Board • Cavity/ Frame: R -30/2x4 • Roof Deck: Wood Siding/sheathing/decking R-30 Attic at Skylight Cathedral Ceilings Wood Framed Ceiling 2x4 @ 24 in. O.C. R 30 0.042 • Roofing: Light Roof (Asphalt Shingle) • Floor Surface: Carpeted Floors Over • Floor Deck: Wood Siding/sheathing/decking R-19 Floor Crawlspace Crawlspace Wood Framed Floor 2x6 @ 16 in. O.C. R 19 0.049 • Cavity/Frame: R -19/2x6 • Cavity/ Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 • Roof Deck: Wood Siding/sheathing/decking Attic Roof Addition Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 • Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 • Exterior Finish: Wood R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/decking • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 R-13 Wall Demising Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 • Other Side Finish: Gypsum Board • Inside Finish: Gypsum Board Ceilings (below • Cavity/Frame: R-9.1 /2x4 R-30 Attic RB attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 30 0.032 • Over Floor Joists: R-20.9 insul. Registration Number: 215-A0214591A-000000000-0000 Registration Date/Time: 2015-08-0322:00:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:31:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Rainbow Drive Addition Calculation Date/Time: 16:30, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: 215156final.ribd CF1 R -PRF -01 Page 8 of 11 WATER HEATING SYSTEMS 01 02 03 04 05 • Inside Finish: Gypsum Board 07 08 Name System Type Distribution Type Water Heater • Cavity/ Frame: R-30 /2x4 Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard • Roof Deck: Wood Siding/sheathing/decking R-30 Attic RB at Skylight Cathedral Ceilings Wood Framed Ceiling 2x4 @ 24 in. O.C. R 30 0.042 • Roofing: Light Roof (Asphalt Shingle) WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 Annual Altered No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0 0.82 EF 199000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Heating System Cooling System Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVAC1 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 2207 Altered No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 215-A0214591A-000000000-0000 Registration Date/Time: 2015-08-0322:00:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:31:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Rainbow Drive Addition Calculation Date/Time: 16:30, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: 215156final.ribd CF1 R -PRF -01 Page 9 of 11 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Name Verified Airflow Efficiency Verified EER Multi -speed Verified Refrigerant Charge Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 11.7 14 No No Cooling Component Location system Status Condition Verification Air Distribution 1 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 350 Not Required Not Required Not Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Insulation Supply Duct Return Duct --- --- --- Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Air Distribution System 1 Ducts located in attic Sealed and tested 6.0 Attic Attic None Altered No System 1 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1 -hers -dist Required 6.0 --- --- --- HVAC - FAN SYSTEMS & HERS VERIFICATION 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required IAQ (indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required Registration Number: 215-A0214591A-000000000-0000 Registration Date/Time: 2015-08-0322:00:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:31:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Rainbow Drive Addition Calculation Date/Time: 16:30, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: 215156final.ribd � CaICERTS, Inc. Registration Number: 215-A0214591A-000000000-0000 Registration Date/Time: 2015-08-0322:00:33 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 CF1 R -PRF -01 Page 10 of 11 HERS Provider: CaICERTS inc. Report Generated at: 2015-08-03 16:31:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Rainbow Drive Addition Calculation Date/Time: 16:30, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: 215156final.ribd CF1 R -PRF -01 Page 11 of 11 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Jennifer Ferris �erc�c��vvz�o Company: Accurate Energy Signature Date: 2015-08-03 16:36:15 r r r r CABEC Address: CEA/HERS Certification Identification (If applicable): 3713 Laguna Way R13-15-10062 UAo,,u Acuriut� .idin F" C4mulUnli City/State/Zip: Phone: Sacramento, CA 95864 916-483-7313 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: `�` cu��eJee Aditi Mukherjee Company: Date Signed: Aditi Mukherjee, Architect 2015-08-03 22:00:33 Address: License: 1448 S. Stelling Rd. C31611 City/State/Zip: Phone: Cupertino, CA 95014 408-455-3793 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0214591A-000000000-0000 Registration Date/Time: 2015-08-03 22:00:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-07082015-744 Report Generated at: 2015-08-03 16:31:10 . ft CALGREEN SIGNATURE DECLARATIONS Project Name-, Project Address: Project Description: SECTION 1 - DESIGN VERIFICATION complete all lines of Section 1- "Design Veffic-.3tion' and subrnAthe ownpleted checklist (Columns 1 and 2� wit6h. the plans and bjildinq permit application to the Building Department. The ovnter and des-gri prcfessictnal responsible or c*mpliarK:e with CalGreen Standards have revised the plans~ and certify that the Iems checked above we herety inwrvo(ated into the project plans and will be implemented into the project r. accordance we, the requirements set =Drth in the 20 13 CaMomia Green Buiioinq Standards Code as adopted, kyy the Cifi� up rt do_ Omer's Sigrvu f6THOSH NARAYAN PILLAI Elate � �HITRA THAMPI C-Artees NFm "lPlease Prnt,' , V1__ 9.4.15 D@4 sior&s Sigrmre Cote ADITI MUKHERJEE Design Prafessionafs Marrie a'lease Print) 11 Sim of La3w *ukss" m&onsibie for CAGFeen mffoarwe Narr* of M'nse RuVssmal resporsii ble for Cal&een =* i Plea se P-.rTt, for Cal0peen compliance SECTION 2 - IMPLEMENTATION VERIFICATION Cornplete, sign and submit the competed checklist, including coilumn 3, together with all original signatures On Section 2 to the Build! na Department pricer to BuAdiriq Department5inal inspectioin. I hate inspected the work add have received 5LrT-xAent clocurnentatbri to werffy and cerffy tiat the pro -identified ect above was constructed in accordance with this Green Bu:idinq Checklist am n accardance w&, the requirements of the 2 r, Californ a Greer Building Standards Code as adcpted by the City oaf Cupenno. S1 cf Xer*,PrO6-�4 responsible for Cal Green. =n. po ance Date( 11� d 'It 71 ,� �'_ a,1Ar__h &)6 A IIA.4'1'& 128 Nanve of Umis_e Waks5ibnal for CaIG�_4 Rlinv Phone 0 , t- t7! t- . , - , - )7n'*,_,"' VA I 1-4y Mt A CL_ . Gcll U0ert5ePMW__-_slsw.al'_ J'VL Email Address for( "'e'r'-' mspon ble D -32e 5. Of � C�&0M_20U4_Ax i1 fifty. r; CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 3 ) Project Name: Santosh Narayan Enforcement Agency: Cupertino City of Permit Number: 15080028 Dwelling Address: 7497 Rainbow dr City: Cupertino Zip Code: 95014 A. Ducted Cooling System Information 01 System Identification or Name System 1 02 System Location or Area Served Location 1 03 System Installation Type Replacement 04 Nominal Cooling Capacity (tons) of Condenser 4 05 Condenser Speed Type Single Speed 06 Cooling System Zonal Control Type Not Zonal 07 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 08 System Bypass Duct Status No Bypass Duct 09 Date of System Airflow Rate Measurement 2016-12-05 10 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement B. Fan Watt Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2. ) 01 ) Fan Watt Verification Device Used. ) Digital Utility Revenue Meter ) MCH -22a Forced Air System Fan Efficacy Measurement - Newly Installed Non -Zoned Systems or Zoned Multi -Speed Compressor C. Forced Air System Fan Efficacy Measurement The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3 01 Actual Tested Watts 702 02 Actual Tested Airflow from MCH -23 (cfm) 1438 03 Required Fan Efficacy (watts/cfm) 0.58 Actual Fan Efficacy (watts/cfm) 0.49 F054 Compliance Statement: System fan efficacy complies Registration Number: 216-A0442519A-M2200002A-0000 Registration Date/Time: 2016-12-05 23:24:55 HERS Provider: CaICERTS CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2016-12-05 17:29:54 2013 Residential Compliance Schema Version: 0.52SDD CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 2 of 3 ) D. Additional Requirements 01 All registers were fully open during the diagnostic test. 02 System fan was set at maximum speed during the diagnostic test. 03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 05 Multi -speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm) criteria in every zonal control mode. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 216-A0442519A-M2200002A-0000 Registration Date/Time: 2016-12-05 23:24:55 HERS Provider: CaICERTS CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2016-12-05 17:29:54 2013 Residential Compliance Schema Version: 0.52SDD CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 3 of 3 ) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: /J� Justin Myers Company: Signature Date: 2016-12-05 17:29:56 Innovative Energy Solutions Address: CEA/ HERS Certification Identification (if applicable): 24 Timber Cove Dr CC2006657 City/State/Zip: Phone: Campbell CA 95008 408-856-5250 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the installation conforms to the requirements given on the plans and specifications approved by the enforcement agency. 4. 1 understand that a HERS rater will check the installation to verify compliance, and that if such checking identifies defects; I am required to take corrective action at my expense. I understand that Energy Commission and HERS Provider representatives will also perform quality assurance checking of installations, including those approved as part of a sample group but not checked by a HERS rater, and if those installations fail to meet the requirements of such quality assurance checking, the required corrective action and additional checking/testing of other installations in that HERS sample group will be performed at my expense. 5. 1 reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and I have ensured that the requirements that apply to the construction or installation have been met. 6. 1 will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Responsible Builder/Installer Signature: Louis Aranda Company Name: (Installing Subcontractor or General Contractor or Position With Company (Title): Builder/Owner) Owner BAY AREA HEATING & AIR CONDITIONING Address: CSLB License: 1805 LITTLE ORCHARD ST #137 931855 City/State/Zip: Phone: Date Signed: SAN JOSE CA 95173 408-674-6845 2016-12-05 23:24:55 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-AO442519A-M2200002A-0000 Registration Date/Time: 2016-12-05 23:24:55 HERS Provider: CaICERTS CA Building Energy Efficiency Standards Report Version: 2013 Rev 1,008 Report Generated: 2016-12-05 17:29:54 2013 Residential Compliance Schema Version: 0.525DD CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3 ) Project Name: Santosh Narayan Enforcement Agency: Cupertino City of Permit Number: 15080028 Dwelling Address: 7497 Rainbow dr City: Cupertino Zip Code: 95014 A. System Information 01 Space Conditioning System Identification or Name System 1 02 Space Conditioning System Location or Area Served Location 1 03 Building Type from CF -113 Single family 04 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? No, credit is not taken 05 Verified Low Leakage Air Handling Unit (VLLAHU) Credit from CF1R? No, credit is not taken 06 j Duct System Compliance Category Replacement I MCH -20d - Complete Replacement or Altered Duct System B. Duct Leakage Diagnostic Test O1 Condenser Nominal Cooling Capacity (ton) 4 02 Heating Capacity (kBtu/h) 95 03 Conditioned Floor Area served by this HVAC system (ft2) 2000 04 Duct Leakage Test Condition Test final 05 Duct Leakage Test Method Total leakage 06 Leakage Factor 0.06 07 Air Handling Unit Airflow (AHUAirflow) Determination Method Heating system method 08 Measured AHUAirflow This field or section is not applicable 09 Calculated Target Allowable Duct Leakage (cfm) 124 10 Actual duct leakage rate from leakage test measurement (cfm) 120 11 Compliance Statement System passes leakage test Registration Number: 216-A0442519A-M2000002A-0000 Registration Date/Time: 2016-12-05 23:24:55 HERS Provider: CaICERTS CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2016-12-05 17:26:55 2013 Residential Compliance Schema Version: 2013.1.007 CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3 ) C. Additional Requirements for Compliance 01 System was tested in its normal operation condition. No temporary taping allowed. Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation 02 Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 03 If a complete replacement, all supply and return register boots were sealed to the drywall. 04 Building cavities were not used as plenums or platform returns in lieu of ducts. 05 If cloth backed tape was used it was covered with Mastic and draw bands. 06 All connection points between the air handler and the supply and return plenums are completely sealed. If the system complies using the Smoke Test method, the smoke test was conducted in accordance with the requirements 07 of Reference Residential Appendix RA3.1.4.3.6. Systems that comply using smoke test shall not be included in sample groups for HERS verification compliance. The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 216-A0442519A-M2000002A-0000 Registration Date/Time: 2016-12-05 23:24:55 HERS Provider: CaICERTS CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2016-12-05 17:26:55 2013 Residential Compliance Schema Version: 2013.1.007 w CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3 ) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: /J� Justin Myers company: Signature Date: 2016-12-05 17:29:56 Innovative Energy Solutions Address: CEA/ HERS Certification Identification (if applicable): 24 Timber Cove Dr CC2006657 City/State/Zip: Phone: Campbell CA 95008 408-856-5250 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the installation conforms to the requirements given on the plans and specifications approved by the enforcement agency. 4. 1 understand that a HERS rater will check the installation to verify compliance, and that if such checking identifies defects; I am required to take corrective action at my expense. I understand that Energy Commission and HERS Provider representatives will also perform quality assurance checking of installations, including those approved as part of a sample group but not checked by a HERS rater, and if those installations fail to meet the requirements of such quality assurance checking, the required corrective action and additional checking/testing of other installations in that HERS sample group will be performed at my expense.' 5. 1 reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and I have ensured that the requirements that apply to the construction or installation have been met. 6. 1 will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Responsible Builder/Installer Signature: Louis Aranda Company Name: (Installing Subcontractor or General Contractor or Position With Company (Title): Builder/Owner) Owner BAY AREA HEATING & AIR CONDITIONING Address: CSLB License: 1805 LITTLE ORCHARD ST #137 931855 City/State/Zip: Phone: Date Signed: SAN JOSE CA 95173 408-674-6845 2016-12-05 23:24:55 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-A0442519A-M2000002A-0000 Registration Date/Time: 2016-12-05 23:24:55 HERS Provider: CaICERTS CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2016-12-05 17:26:55 2013 Residential Compliance Schema Version: 2013.1.007 n CALGREEN RESIDENTIAL CHECKLIST - MANDATORY ITEMS COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION CUPERTINO ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildingCcOcupertino.org PURPOSE: The 2013 CalGreen Code applies to additions or alterations of existing residential buildings where the addition or alteration increases the building's conditioned area, volume, or size and also applies to all new low-rise residential buildings, high-rise residential buildings, or both. Existing site and landscaping improvements that are not otherwise disturbed are not subject to the requirements of CALGreen. Project Name: Project Address: Project Description: Instructions: 1. The Owner or the Owner's agent shall employ a licensed professional experienced with the California Green Building Standards Codes to verify and assure that all required work described herein is properly planned and implemented in the project. 2. The licensed professional, in collaboration with the owner and the design professional shall initial Column 2 of this checklist, sign and date Section 1 - Design Verification at the end of this checklist and have the checklist printed on the approved plans for the project. 3. Prior to final inspection by the Building Department, the licensed professional shall complete Column 3 and sign and date Section 2 - Implementation Verification at the end of this checklist and submit the completed form to the Building Inspector. Column 2 Column 3 MANDATORY FEATURE OR MEASURE Project Verification Requirements Planning and Design - Site Development 4.106.2 Storm water drainage and retention during construction. A plan is developed and implemented to manage storm water drainage during ❑ ❑ construction. 4.106.3 Grading and paving. The site shall be planned and developed to keep surface water away from buildings. Construction plans shall indicate how ❑ site grading or a drainage system will manage all surface water flows. Page 1 of 5 CalGreen_2014.doc revised 11104114 A4.2 General 4.201.1 Low-rise residential buildings shall meet or exceed the minimum standard design required by the California Energy Standards. A4.3 WATER EFFICIENCY AND CONSERVATION Indoor Water Use 4.303.1 Water conserving plumbing fixtures and fittings. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the following: ❑ 4.303.1.3.2 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank -type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specifications for Tank -type Toilets. ❑ 4.303.1.3.2 Urinals. The effective flush volume of urinals shall not exceed 0.5 gallons per flush. ❑ 4.303.1.3.1 Single Showerheads. Showerheads shall have a maximum flow rate of not more than 2.0 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for showerheads. ❑ 4.303.1.3.2 Multiple Showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve ❑ shall not exceed 2.0 gallons per minute at 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. ❑ 4.303.1.4.1 Residential lavatory faucets. The maximum flow rate of residential lavatory faucets shall not exceed 1.5 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. ❑ 4.303.1.3.2 Lavatory faucets in common and public use areas. The maximum flow rate of lavatory faucets installed in common and public use areas (outside of dwellings or sleeping units) in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. ❑ 4.303.1.4.3 Metering faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.25 gallons per cycle. ❑ 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. 4.303.2 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, ^/ Lld and shall meet the applicable standards referenced in Table 1401.1 of the California Plumbing Code. Page 2 of 5 CalGreen_2014.doc revised I1/04114 Outdoor Water Use 4.304.1 Irrigation controllers. Automatic irrigation systems installed at the time of final inspection shall be weather -based. ❑ 4.304.1.1 Controllers shall be weather- or soil moisture -based controllers that automatically adjust irrigation in response to changes in plants' needs as weather conditions change. ❑ ❑ ❑ 4.304.1.2 Weather -based controllers without integral rain sensors or communication systems that account for local rainfall shall have a separate wired or wireless rain sensor which connects or communicated with the controller(s). Soil moisture -based controllers are not required to have rain sensor input. .. .4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY Enhanced Durability and Reduced Maintenance 4.406.1 Rodent proofing. Annular spaces around pipes, electric cables, conduits, or other openings in plates at exterior walls shall be protected ❑ ❑ against the passage of rodents by closing such openings with cement mortar, concrete masonry or similar method acceptable to the enforcing agency. Construction Waste Reduction, Disposal and Recycling 4.408.2 Construction waste management plan. Where a local jurisdiction does not have a construction and demolition waste management ordinance, a ❑ construction waste management plan shall be submitted for approval to the enforcing agency. Building Maintenance and Operation 4.410.1 Operation and maintenance manual. At the time of final inspection, ❑ ❑ an operation and maintenance manual shall be provided to the building occupant or owner. A4.5 Fireplaces 4.503.1 General. Install only a direct -vent sealed -combustion gas or sealed ❑ ❑ wood -burning fireplace, or a sealed woodstove. Pollutant Control 4.504.1 Covering of duct openings and protection of mechanical during construction. Duct openings and other related air El distribution component openings shall be covered during construction. 4.504.2.1 Adhesives, sealants and caulks. Adhesives, sealants and caulks ❑ shall be compliant with VOC and other toxic compound limits. 4.504.2.2 Paints and coatings. Paints, stains and other coatings shall be 13/ ❑ compliant with VOC limits. 4.504.2.3 Aerosol paints and coatings. Aerosol paints and other coatings shall be compliant with product weighted MIR Limits for ROC and other toxic ❑ compounds. Page 3 of 5 CalGreen_2014.doc revised 11104114 4.504.2.4 Verification. Documentation shall be provided to verify that ❑ ❑ compliant VOC limit finish materials have been used. 4.504.3 Carpet Systems. Carpet and carpet systems shall be compliant with ❑ VOC limits. 4.504.4 Resilient flooring systems. Eighty (80) percent of floor area receiving resilient flooring shall comply with the VOC-emission limits defined in Low �y❑ the Collaborative for High Performance Schools (CHPS) -emitting Materials List or be certified under the Resilient Floor Covering Institute (RCFI) FloorScore program. 4.504.5 Composite wood products. Particleboard, medium density ❑ fiberboard (MDF), and hardwood plywood used in interior finish systems shall comply with low formaldehyde emission standards. Interior Moisture Control 4.505.2 Concrete slab foundation. Required vapor retarders and capillary ❑ ❑ breaks are also required to comply with CalGreen Section 4.505.2.1. 4.505.3 Moisture content of building materials. Moisture content of building ❑ ❑ materials used in wall and floor framing is checked before enclosure. Indoor Air Quality and Exhaust 4.506.1 Bathroom exhaust fans. Exhaust fans which terminate outside the ❑ building are provided in every bathroom. Environmental Comfort 4.507.2. Duct systems are sized and designed and equipment is selected using the following methods: 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. ❑ 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent. 3. Select heating and cooling equipment according to ACCA 36-S (Manual S) or equivalent. INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS Qualifications 702.1 Installer training. HVAC system installers are trained and certified in ❑ ❑ the proper installation of HVAC systems. 702.2 Special inspection. The Licensed Professional responsible to verify ❑ ❑ CALGreen compliance is qualified and able to demonstrate competence in the discipline they inspect and verify. Verifications 703.1 Documentation. Verification of compliance with CALGreen may include construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing ❑ ❑ agency which show substantial conformance. Implementation verification shall be submitted to the Building Department after implementation of all required measures and prior to final inspection approval. Page 4 of 5 CalGreen_2014.doe revised 11104114