15030160Ed CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 1195 YORKSHIRE CT CONTRACTOR: DELUXE AIR PERMIT NO: 15030160 OWNER'S NAME: WOODLAND, CA 95776 PHONE NO: (530) 662-5008 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL E] COMMERCIAL REPLACE A/C UNIT LIKE FOR LIKE (1 ,, ^^ License Class C.' V Lic. It q01 ws 3 q ContractoDC—LUX& r, ()Z— Date 3/C20' �s- I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's ' Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation: $6814 I have and will maintain Worker's Compensation Insurance, as provided for by APN Number: 36211009.00 Occupancy Type: Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, 180 DAYS F ST CALLED INSP CTION* costs, and expenses which may accrue against said City in consequence of the Issued by: Dat e: 2(p f granting of this permit. Additionally, the applicant understands and will comply with all non -point source egulations per the Cupertino Municipal Code, Section RE-ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is 918. Signature Date 302 i S installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cup tmo Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 2 , 25533, a Section 3700 of the Labor Code, for the performance of the work for which this Owner or authorized agents Dater A 11 permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 918. Signature Date CUPERTINO GENERAL PERMIT APPLICATION - ' MEP COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION \� 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 �v MISC(408),777-3228 • FAX (408) 777-3333 • buildingcDcupertino.org ❑ PLUMBING Il_I MECHANICAL ❑ ELECTRICAL ❑ MISCELLANEOUS PROJECT ADDRESSI' -J n 5 �- l R � 1C CT APN # �' ()f . jj . 6 , , ^ FAX CONTACT NAME ( PHONEM _ OQ Q E-MAIL STREET ADDRESS/ n' / (O CITY; STATE,VZIPj//� ` C? yARCHITECT FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNERAGENT P CONTRACTOR ❑ CONTRACTOR AG HENT ❑ ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME \ f ` LICENSE NUMBER J LICENy� TYP O ` BUS. LIC # COMPANY' D E l U _ T- E-MAIL FAX /" qg r C f 71 { STREET ADDRESS 10A/'/� J `•(- / ( CIT , ST6ArT�E; IP o9N � n n -7 7 7 Y �/'l `j ( PHONE ARCHITECT/ENGINEER NAME(' LICENSE NUMBEWR BUS. LIC # COMPANY NAME E-MAII FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF ❑ SFD or DUPLEX ❑ MULTI-FAMII.YPROJECT IN WILDLAND ❑ YES PROJECT IN El YES IS THE BLDG AN ❑ YES BUILDING: ❑ COMMERCIAL URBAN INTERFACE AREA ❑ NO FLOOD ZONE ❑ NO EICHLER HOME? ❑ NO DESCRIPTION OF WORK nJ5'f� C A QU T D06 IZ 0aF1 &-b (F tZ t Ac- `v� L TOTAL VALUATION: 8 t 1E1VED By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the prqjerter's behalf. I have read this application and the information I have provided is correct I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to build�constru�Ction, autho ' representatives of Cupertino to enter the above -identified property for inspection purposes. Signature ofApplicant/Agent. Date: SVMENTAL INFORMATION REQUIRED „ ; oFFrcE usEbN_ No g IN 112, MEPMiscApp_2011.doc Devised 06121/11 CITY OF CUPERTINO �� LTi IV i C9r7M A Tl112 — RT TTI .'nINV DIVICION LaADDRESS: 1195 yorkshire DATE: 03/26/2015 REVIEWED BY: Mendez Plan Check P'ee: APN: BP#: EVALUATION: $6,814 *PERMIT TYPE: Mechanical Permit PLAN CHECK TYPE: Alteration / Addition / Repair PRIMARY SFD or Du lex p PME Plan Check: PENTAMATION FURN/AC PERMIT TYPE: i USE: Permit Fee: suppl. Irrsr) Pee WOR* lace ac unit �re SCOPE PME Permit Fee: APPLIANCE / EQUIP TYPE FEE ID QTY UNITS BP FEES A/C Units (<=10K cfm) 1BREMAIR 1 # $72 � TOTALS: $72 00 °� ` �� Mech. Plan Check 0.0 1 hrs $0.00 Plumb. Pkin Check Elec, Plan Check Mech. Permit Fee: IMPERMIT Plumh, Permit Hee: t lec PermiF Fee: Other Mech. Insp. 0.0 hrs $48.00 Other Plumb Insp Other E-lec. Imp. irlech. ling. Fee: Plumb, hash. Fee. Elec. /nap. Fee: NOTE: This estimate does not includefees due to other Departments (Le. rianntng, rumic irvurx3, rtre,!ounstury ouwct �s�u as y va •svvo •-/1H/LI/'I 1%O ))Ont JOT Qddlt'l info. "93tssu, csa... aiswc cw -1 � r. .............. FEE ITEMS (Tee Resolution 11-053 E . 7/1/13) ... _----------- ---------- FEE QTY/FEE MISC ITEMS Plan Check P'ee: .4uppl. P(I Pee PME Plan Check: $0.00 Permit Fee: suppl. Irrsr) Pee PME Unit Fee: $72.00 PME Permit Fee: $48.00 Construchon Tax: T -T- Administrative Fee: 1ADMIN $45.00 Work Without Permit? ® Yes (E) No $0.00 Ildvatneed PICFrmin4y7 Fen's: i Travel Documentation Fee: ITRA VDOC $48.00 Strom Motion Fee: IBSEISMICR $0.89 Select an Administrative Item Bldp- Stds Commission Fee: 1BCBSC $1.00 ag $214.89 $0.0011- _ - 4.20TL FES $214.89 Revised: 02/14/2015 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 1 of 7 ) Project Name: 1195 Yorkshire Court Enforcement Agency: City of Cupertino Permit Number: 15030160 Dwelling Address: 1195 Yorkshire Court City: Cupertino Zip Code: 95014 A. General Information 01 Dwelling Unit Name 1195 Yorkshire Court 02 Climate Zone 4 06 Dwelling Unit Conditioned Floor Area 09 Number of space conditioning (SC) 03 (ft2) 1400 04 systems being altered in this dwelling 1 Installing SC System unit. by this SC 05 Certificate of Compliance Type `. Prescriptive alterations (CF1R-ALT) 06 Method used to calculate HVAC loads NotApplicableEquipmentChangeout 07 Calculated dwelling unit Sensible This field or section is not applicable 08 Calculated Dwelling Unit Heating Load This field or section is not applicable system Cooling Load (Btuh) new duct entirely new (Btu h) Name MCH -01b Prescriptive Alterations -Space Conditioning Systems Ducts and'1=ans k B. Space Conditioning (SC) System Information;; ' � 01 02 03 04"05` 06 07 09 10 CFA served Is the SC Installing a Installing SC System SC System by this SC system a refrigerant Installing new SC Installing more entirely Installing Identification or Location or Area System ducted containing system than 40 feet of new duct entirely new Name Served (ft2) system? component? components? ducts? system? SC system? Alteration Type Altered space System 1 Location 1 1400 Yes Yes Yes No No No conditioning I stem Registration Number: 215-A0158274A-M0100002A-0000 Registration Date/Time 2015-06-12 17:11:25 i V, 411 �11 HERS Provider: CalCERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-06-12 17:06:34 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 2 of 7 ) C. Space Conditioning (SC) System Alterations Compliance Information 01 02 03 04 05 06 07 08 09 10 11 12 13 Condenser or Package Unit System Identification or Name Cooling Efficiency Type Cooling Efficiency Value �This`seg, n does�not apply to this project: Condenser or Package Unit Model Number Condenser or Package Unit Serial Number System Rated Cooling Capacity at Design Conditions (BTUH) Central Fan System 1 ,t .. Kenmore TCA748GK200 N/A iii: 4 Notes: Integrated Heating Cooling New or (CFI) System Altered Heating Minimum Altered Cooling Minimum Required Replaced New Ventilation Identification Heating Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Duct Duct System or Name System Type Component Type Value System Type Component Type Value Type Length R -Value Status This field No heating ; .. or This field Outdoor System 1 Central gas componen section is or section Central condensing SEER 17 Setback LTE40Ft R6 Not a CFI furnace t altered not ' is not split AC unit system applicabl applicable e E. Installed Cooling Equipment information: D. Installed Heating Equipment information •, s 02 03 04 05 06 07 08 Condenser or Package Unit System Identification or Name Cooling Efficiency Type Cooling Efficiency Value �This`seg, n does�not apply to this project: Condenser or Package Unit Model Number Condenser or Package Unit Serial Number System Rated Cooling Capacity at Design Conditions (BTUH) Condenser Rated Nominal Capacity (ton) System 1 ,t .. Kenmore TCA748GK200 N/A iii: 4 Notes: E. Installed Cooling Equipment information: 01 02 03 04 05 06 07 08 Condenser or Package Unit System Identification or Name Cooling Efficiency Type Cooling Efficiency Value Condenser or Package Unit Manufacturer Condenser or Package Unit Model Number Condenser or Package Unit Serial Number System Rated Cooling Capacity at Design Conditions (BTUH) Condenser Rated Nominal Capacity (ton) System 1 SEER 17 Kenmore TCA748GK200 N/A 48000 4 Notes: Registration Number: 215-A0158274A-M0100002A-0000 Registration Date/Time 2015-06-12 17:11:25 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-06-12 17:06:34 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 3 of 7 ) F. Extension of Existing Duct System, Greater Than 40 Feet This section does not apply to this project. G. Installed Duct System information This section does not apply to this project. H. Installed Air Filter Device Information This section does not apply to this project. I. Air Filter Device Requirements Registration Number: 215-A0158274A-M0100002A-0000 This section does not apply to this project : 4 E Registration Date/Time 2015-06-12 17:11:25 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-06-12 17:06:34 CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3 ) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ea&61& Caitlin Moore G ' 1. oot& Company: Signature Date: 2015-06-12 17:08:40 DuctTesters, Inc. Address: CEA/ HERS Certification Identification (if applicable): 118SElm Ave City/State/Zip: Phone: Ripon CA 95366 209-579-5000 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided;on this Certificate of Installation is true and correct. 2. 1 am eligible under Division„3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation' of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest;to the: declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer ;:. 3. The constructed or installed features, materials, comporents`or manufactured devices (the installation) identified on this Certificate of Installation conforms to a'll..applicable codes and,,regulations, and, the installation conforms to -the requirements given on the plans andspecifications approved by the enforcement agency. .�: . 4. 5 a 4. 1 understand that`s HERS rater will check the`installation to verify compliance, and that ifrsuchycheckmg identifies defects, I a{m required to take corrective actidn'at my,expense. I',& understand4that Energy Commsson`and HERS Provider representatives willalsoperformguality assurance checking of installations, including thosey,approved as part of a.sarpple:grbbp but not[checked by a�HERS!.rater; and if those m`stallatio_ns fail.to meet the requirements of such quality assurance checking, the required corrective action and additional. checking/testing of other installations in that HERS sample groupwillbe performed at mjr expense.,N. S. I reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and I have ensured that the requirements that apply to the construction or installation have been met. 6. 1 will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/installer Name: Responsible Builder/Installer Signature: Roy Bradshaw fi. 4wgav Company Name: (Installing Subcontractor or General Contractor or Position With Company (Title): Builder/Owner) Installer SEARS HOME IMPROVEMENT PRODUCTS INC Address: CSLB License: 1024 Florida Central Parkway 721379 City/State/Zip: Phone: Date Signed: LONGWOOD FL 32752 407- 551-6000 2015-06-12 17:11:25 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0158274A-M2000002A-0000 Registration Date/Time: 2015-06-12 17:11:25 HERS Provider: CaICERTS CA Building Energy Efficiency Standards Report Version: 2014-05-08 Report Generated: 2015-06-12 17:07:56 2013 Residential Compliance Schema Version: 0.51SDD CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 4 of 7 ) J. HERS Verification Requirements 01 02 03 04 05 06 07 08 09 10 MCH2O MCH21 MCH22 MCH23 MCH25 MCH28 Exemption from Minimum Exemption R -Value for AHU Fan AHU SC System SC System From Duct Duct Ducts In Ducts Located Efficacy Airflow Identification or Location or Area Leakage Leakage Conditioned In Cond Space (W per Rate (cfm Refrigerant Return Duct Design Name Served Requirements Test Space Verification cfm) per ton) Charge Table 150.0-C or D System 1 Location 1 No exemptions Yes Not applicable No No No No No Registration Number: 215-A0158274A-M0100002A-0000 Registration Date/Time 2015-06-12 17:11:25 HERS Provider: CalCERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-06-12 17:06:34 t Registration Date/Time 2015-06-12 17:11:25 HERS Provider: CalCERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-06-12 17:06:34 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 5 of 7 ) K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Heating Equipment Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency 01 Regulations. Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant 02 to program the temperature set points for at least four different periods in 24 hours. See Sections 150.0(i), 110.2(b). Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections 03 150.0(h)1 and 2). Furnace Temperature Rise .Central::forced-air`heating-furnace installations must be configured to operate at or below the furnace manufacturer's maximum 04 inlet -to -outlet temperature 'rise specification. See Se.ction.150:-0(h)4. 05 Standby Losses and Pilot Lights: Farr=type central furnaces may not have�a continuously burning pilotMlight' ,Section 110 , and Section 110.2(d). "� iw,.x ,,.� � t Y '� N• } r , r�- w`a ( .. �. y d X5;1 q % k .F i ,� k Cooling Equipment �r.�.._r.. �...F? 4 ,�,. LJ� }Sir . 1s+:C`✓'^4a�`� Equipment Efficiency: All cooling equipment must�meet the= mi'nimurn efficiency�"�equirements=of,"Section 110.x1 and Section 1f0.2(a'i)and the Appliance Efficiency 06 Regulations. Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R -value and protection requirements of Section 07 150.0(j)2 and 3, and Section 150.0(m)9. 08 Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet. See Section 150.0(h)3A. Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section 09 150.0(h)1 and 2. Air Distribution System Ducts, Plenums and Fans Insulation: In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be 10 required by the prescriptive or performance requirements. See Section 150.0(m)1. Registration Number: 215-A0158274A-M0100002A-0000 Registration Date/Time: 2015-06-12 17:11:25 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-06-12 17:06:34 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 6 of 7 ) K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Connections and Closures: All installed air -distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 or 11 enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference Residential Appendix RA3.1.4.3.8. Heat Pump Thermostat 12 A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c). 13 The thermostat shall be installed in accordance with the manufacturers published installation specifications 14 First stage of heating shall be assigned.to heat pump heating. 15 Second stage back up heating shall be set to come on -;on y when the indoor set temperature cannot be met F. K 4p'� A� �t ` % �ZY� YM nfi. 3ti` r� fft ,yYk [!fi,) The responsible person signature on this compliance documeynM affirms that all applicable'requirements in�thi§Aable have been met, ei" Registration Number: 215-A0158274A-M0100002A-0000 > t .>N•u., '' ;R a dw Z< `q + ",%k c { a inx �' *,; ,t 8s '"'�,,( '_.; Registration Date/Time: 2015-06-12 17:11:25 HERS Provider: CalCERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-06-12 17:06:34 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 7 of 7 ) Documentation Author's Declaration Statement 1.1 certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: GZd&l Moore, Caitlin CROOW Company: Signature Date: DuctTesters, Inc. 2015-06-12 17:08:40 Address: CEA/ HERS Certification Identification (if applicable): 118SElm Ave City/State/Zip: Phone: Ripon CA 95366 209-579-5000 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. 1 am eligible under Division 3 of.the Business and Professions Code in the,:applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer' , ,. 3. The constructed or installed features, materials, components or manufactured de'vices'(the°installation) identified on'thist ertifi-atewof Installatioril-conforrns to alltapplicable codes and regulations, and the installation conforms to the requirements iven on the ' ans and s `ecifications a roved,b the enforcements enc . " U q g p p pp ya Y r r ,g �. 4. I reviewed a co of the Certificate ofCom. liance, a raved b the enforcement;agency that'identifies thespecific reguirements,forthe scope of$constiuction or mstaliation identified on this Certificate of copy p Y SPP k s 4 Installation, and I have ensured thatthe requirements that apply to the construction or installation have been met F ' tl,��� �.-.tri �ii.. +� ��i`Vxivl..� 5. 1 will ensure that a registered copy of this Certificate of Installation shall,be posted, or made available with the building permits) is"sued for,the building, and made available to the enforcement agency for all yidr' ub a,r,.,aC".:': tl .w' �'x:�MPu h 3� 'M`yn ,ri' �r. �.. �? applicable inspections. I understand that a registered copy"' this Certificate of installation is required to lie inclu6cl with the documentation the"builder'provides to the building owner at occupancy. Responsible Builder/Installer Name: Responsible Builder/Installer Signature: Bradshaw, Roy Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Position With Company (Title): SEARS HOME IMPROVEMENT PRODUCTS INC Installer Address: CSLB License: 1024 Florida Central Parkway 721379 City/State/Zip: Phone: Date Signed: LONGWOOD FL 32752 407- 551-6000 12015-06-12 17:11:25 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0158274A-M0100002A-0000 Registration Date/Time: 2015-06-12 17:11:25 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-06-12 17:06:34 CERTIFICATE OF INSTALLATION CI`211-MCH-20-1-1 Duct Leakage Diagnostic Test (Page 1 of 3 ) Project Name: 1195 Yorkshire Court Enforcement Agency: Cupertino City of Permit Number: 15030160 Dwelling Address: 1195 Yorkshire Court city: Cupertino Zip Code: 95014 A. System Information 01 Space Conditioning System Identification or Name System I 02 Space Conditioning System Location or Area Served Location 1 03 Building Type from CF -113 Single family 134 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1.R? No, credit is not taken 05 Verified Low Leakagp.Air'Handling Unit (VLLAHU) Credit from CF1R? No, credit is not taken 06 Duct System'CoMpliance Category Alteration using smoke test P7 MCH-20eSealing All Accessible bW-Leaks using STi 3 B. Duct Leakage Diagnostic Test 01 Condenser Nominal Cooling Capacity (ton) 4 02 Heating Capacity (kBtu/h) 0 03 Conditioned Floor Area served by this HVAC system (ft2) 1400 04 Duct Leakage Test Condition Test final 05 Duct Leakage Test Method Total leakage 06 Leakage Factor 0.15 07 Air Handling Unit Airflow (AHUAirflow) Determination Method Cooling system method 08 Measured AHUAirflow This field or section is not applicable 09 Calculated Target Allowable Duct Leakage (cfm) 240 10 Actual duct leakage rate from leakage test measurement (cfm) 540 11 Compliance Statement: System passes using smoke test of an altered HVAC system in an existing building. No visible smoke exits the accessible portions of the duct system. Smoke is only emanating from air -handling unit (AHU) cabinet and non accessible portions of the duct system. Note - Accessible is defined as having access thereto, but which first may require Registration Number: 215-A0158274A-M2000002A-0000 Registration Date/Time: 2015-06-12 17:11:25 HERS Provider: CaICERTS CA Building Energy Efficiency Standards Report Version: 2014-05-08 Report Generated: 2015-06-12 17:07:56 2013 Residential Compliance Schema Version: 0.51SDD CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3 ) B. Duct Leakage Diagnostic Test removal or opening of access panels, doors, or moving similar obstructions. If access to the ducts requires an object to be demolished or deconstructed then sealing of those ducts is not required C. Additional Requirements for Compliance 01 System was tested in its normal operation condition. No temporary taping allowed. Outside air (OA) ducts for Central Fan Integrated (CFI) ventilation systems, shall not be sealed/taped off during duct leakage testing. CFI OA ducts that utilize controlled motorized dampers, that open only when OA ventilation is required to meet 02 ASHRAE Standard 62.2, and close when OA ventilation is not required, may be configured to the closed position during duct leakage testing. 03 All supply and return register boots were sealed to the drywall. 04 Building cavities were;`notlused as plenums or platform returns in lieu of ducts. 05 If cloth backedJaDe.*as used it was covered with Mastic and draw bands. 06 All connection points between the air handler and the,supply and return plenums are -completely sealed. :... ? sy— If the system complies. using the Smoke Test method, th°esmoke test�was conducted in accordance with the req'uirements of 07 Reference Residential Appendix RA3 14,:3 6 Systems that"'comply using smoke test hall.-not,be included m sample.groups for HERS verification compliance Y rc r The responsible persons signature on this compliance document affirms that all app4licable requirements in this table have been met. Registration Number: 215-A0158274A-M2000002A-0000 Registration Date/Time: 2015-06-12 17:11:25 HERS Provider: CaICERTS CA Building Energy Efficiency Standards Report Version: 2014-05-08 Report Generated: 2015-06-12 17:07:56 2013 Residential Compliance Schema Version: 0.51SDD CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT HVAC) (Page 3 of 3 ) Documentation Author's Declaration Statement 1.1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: e;C&(M Moore, Caitlin 0400W 1. Company: Signature Date: DuctTesters, Inc. 2015-06-12 16:00:21 Address: CEA/ HERS Certification Identification (if applicable): 118SElm Ave City/State/Zip: Phone: Ripon CA 95366 209-579-5000 Responsible Person's Declaration statement:. I certify the following under penalty of perjury, under the',laws`of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the.Business and Professions Code to,accept.responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part'6 of the CaliforniaCode of Regulations t; 4. The building design features or system design features identified onrthis Certificat66f Compliance arefconsistentwitWihe information provided on other applicable'compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for4ap'pprov6IWtl this building permit application:`12 4 '° 5. 1 will ensure that a registered copy ofahis Certificate of Compliance shall be made available with the building pe'rmit(s),,issued for therbdilding, and ►rade available tq=;thesenforcement agency for all applicable inspections. I understand that a registered copy of this°Cert ficate of Compli�ance�,is required to b,e,_included with thsgcumentation. they builder provides to:Athe building owner at occupancy. Responsible Designer Name: " r� Responsible Designer Signature.. r Bradshaw, Roy Company: Date Signed: SEARS HOME IMPROVEMENT PRODUCTS INC 2015-06-12 16:04:50 Address: License: 1024 Florida Central Parkway 721379 City/State/Zip: Phone: LONGWOOD FL 32752 407- 551-6000 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0158274A-000000000-0000 Registration Date/Time: 2015-06-12 16:04:50 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-06-12 16:00:27 Schema Version: 0.555SDD CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3 ) Project Name: 1195 Yorkshire Court Enforcement Agency: City of Permit Number: 15030160 Cupertino Dwelling Address: 1195 Yorkshire Court City: Cupertino Zip Code: 95014 A. System Information 01 Space Conditioning System Identification or Name System 1 02 Space Conditioning System Location or Area Served Location 1 03 Building Type from CF -1R Single family 05 Verified Low Leakage Ducts in Conditioned Space No; credit is not taken 04 (VLLDCS) Credit from CF1R? 0.15 07 Verified Low Leakage Air Handling Unit (VLLAHU) Credit No, credit is not taken 05 from CF1R? This field or section is not applicable 06 Duct System Compliance Category Alteration using smoke test MCH -20e -Sealing All Accessible=Leaks using Smoke}Test's q UY a'�1 .. 'cT..'S'"� F i�3. � ":k _.. # �4.. ih. � `m'.. �_� ♦^_, .,,. _ s �. .�. %k.s 1 . i..,�'�*� �>f� .. �. - .... F �.v � r rvr; �) ( S 'mak 's' Y ^k �e ' t: f*= 5.. Y frr ;L - n B. Duct Leakage Diagnostic Test "� 01 Condenser Nominal Cooling Capacity (ton) 4 02 Heating Capacity (kBtu/h) 0 03 Conditioned Floor Area served by this HVAC system (ft2) 1400 04 Duct Leakage Test Condition Test final 05 Duct Leakage Test Method Total leakage 06 Leakage Factor 0.15 07 Air Handling Unit Airflow (AHUAirflow) Determination Method Cooling system method 08 Measured AHUAirflow This field or section is not applicable 09 Calculated Target Allowable Duct Leakage Rate (cfm) 240 10 Actual duct leakage rate from leakage test measurement (cfm) 540 11 Compliance Statement: System passes using smoke test of an altered HVAC system in an existing building. No visible smoke exits the accessible portions of the duct system. Smoke is only emanating from air -handling unit (AHU) cabinet and non accessible portions of the duct system. Note - Accessible is defined as having access thereto, but which first may require Registration Number: 215-A0158274A-M2000002A-M20A Registration Date/Time: 2015-06-15 14:22:47 HERS Provider: CaICERTS CA Building Energy Efficiency Standards Report Version: 2014-05-08 Report Generated: 2015-06-12 17:09:45 2013 Residential Compliance Schema Version: 0.551SDD CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3 ) B. Duct Leakage Diagnostic Test 01 removal or opening of access panels, doors, or moving similar obstructions. If access to the ducts requires an object to be demolished or deconstructed then sealing of those ducts is not required 12 Notes: C. Additional Requirements for Compliance 01 System was tested in its normal operation condition. No temporary taping allowed. Outside air (OA) ducts for Central Fan Integrated (CFI) ventilation systems, shall not be sealed/taped off during duct leakage testing. CFI OA ducts that utilize controlled motorized dampers, that open only when OA ventilation is required to meet 02 ASHRAE Standard 62.2, and close when OA ventilation is not required, may be configured to the closed position during duct leakage testing. 03 All supply and return ;register boots were sealed to the drywall. 04 Building cavities were not used as plenums or platform returns in lieu of ducts. 05 If cloth backed tape was used it -was covered with Mastic and draw bands ,. 06 � ,� r o � � . All connection points between the air Handler and the supply andreturn plenums are completely sealed -{ j° If the system complies usingthe Smoke Test'method, the smoke test was "conducted in accordance with the requirements 07 of Reference -Residential Appendix RA3 14 3Q 6 S, temps thaVcom ply using smoke test shall,d'ot be included in sample groups for HERS verification compliance. x 08 Verification Status: Pass - all applicable requirements are met 09 Correction Notes for this table: The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. D. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 1 01 1 Complies: All specified verification protocol requirements on this document are met. Registration Number: 215-A0158274A-M2000002A-M20A Registration Date/Time: 2015-06-15 14:22:47 HERS Provider: CaICERTS CA Building Energy Efficiency Standards Report Version: 2014-05-08 Report Generated: 2015-06-12 17:09:45 2013 Residential Compliance Schema Version: 0.551SDD CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3 ) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Caitlin Moore O&ffobC4rsow-/ Company: Date Signed: DuctTesters, Inc. 2015-06-12 17:10:01 Address: CEA/ HERS Certification Identification (if applicable): 118SElm Ave City/State/Zip: Phone: Ripon CA 95366 209-579-5000 Responsible Person's Declaration statement I certify the following under penalty. perjury, under the laws of the State of California: 1. The information provide -don this Certificate of Verification is true and correct. 2. 1 am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features; materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified onthe Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections ofthe Certificate(s) .Of InstaIiation (CF2R)*signed'and'submitted'by the person(s) responsible for the construction or installation conforms to the requirements specifiedjo,n the Certificate(s)�of Compliance (CF1R) approved by fhe�enforcement''agency. 5. I will ensure that.a registered copy�rof this Certificate of Verification�shall be posted, or made available with the building permits) issued for the building, and made,available°.to the.;enforcement agency for all applicablerinspections I understand that a registered,.copy o' s,Certificate of.; i Verification is:i equired to i included with the documentation the buwltler`provides to the building owner at'occupancy. Verification .. S.�.a. S t� z� ;r.' Builder Or Installer Information As Shown On"Th4tertificateiOf Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): SEARS HOME IMPROVEMENT PRODUCTS INC Responsible Builder or Installer Name: CSLB License: Roy Bradshaw 721379 HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) Tested HERS Rater Information HERS Rater Company Name: DuctTesters, Inc. Responsible Rater Name: Responsible Rater Signature: Tony Souza Responsible Rater Certification Number w/ this HERS Provider: Date Signed: CC2006052 2015-06-15 14:22:47 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0158274A-M2000002A-M20A Registration Date/Time: 2015-06-15 14:22:47 HERS Provider: CaICERTS CA Building Energy Efficiency Standards Report Version: 2014-05-08 Report Generated: 2015-06-12 17:09:45 2013 Residential Compliance Schema Version: 0.551SDD CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E I Alterations to Space Conditioning Systems (formerly CF -IR -ALT HVAC) (Page 1 of 3 ) I Project Name: 1195 Yorkshire Court I Date Prepared: 2015-06-12 A. General Information CF111-ALT 02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT 02 document for each dwelling unit. 01 Project Name 1195 Yorkshire Court 02 Date Prepared 2015-06-12 03 Project Location 1195 Yorkshire Court 04 Building Type Single family 05 CA City Cupertino 06 Dwelling Unit Name 1195 Yorkshire Court 07 Zip Code 95014 08 Dwelling Unit Conditioned 1400 . 4.-.t*: r� _ k:a: i+.t� " :.; ��:='' � 3 n ,0'd; �x-., `��„ Floor Area (ft2) SC System SC System CFA served . 4syystem a? refrige'rarit Number of space conditioning T )... 09 Climate Zone 4 10 (SC) systems in this dwelling 1 ducted c containing system more than 46 unit. entirely new .�tk � B. Space Conditioning (SC) System Information $ 01 02 03 04E� 06 07 ` 08 09 10 ...'�; the SC aY•n�m `"✓:a Installing a . 4.-.t*: r� _ k:a: i+.t� " :.; ��:='' � 3 n ,0'd; �x-., `��„ SC System SC System CFA served . 4syystem a? refrige'rarit 3hlnstalling"new�SCInstalling T )... ',Installing,, :`1, Identification or Location or Area by this SC ducted c containing system more than 46 entirely new entirely new Name Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type Altered space System 1 Location 1 1400 Yes Yes Yes No No No conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)1Diib) This section does not apply to this project. Registration Number: 215-A0158274A-000000000-0000 Registration Date/Time: 2015-06-12 16:04:50 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-06-12 16:00:27 Schema Version: 0.555SDD CERTIFICATE OF COMPLIANCE CF111-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT HVAC) (Page 2 of 3 ) D. Altered Space Conditioning System (Sections 150.2(b)1E and F) 01 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value Central gas No heating This field or This field or Central split Outdoor Less than or System 1 furnace component section is not section is not AC condensing SEER 17 Setback equal to 40 R-6 altered applicable applicable unit feet Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems Ducts and Fans_: -Duct insulation requirement for new plenums: R6. CF211-MCH-20-H & CF3R-MCH-20-H — Duct Leakage testingxeq fired when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced. -Leakage rate compliance: _< 15%, or 510% leakage to outside, dr seal all accessible leaks. C172R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge:Verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow >t..300 CFM/ton required when MCW25 is required. Exceptions: < ,f 1i f -Duct systems registered with HERS provider as previously sealed are -,exempt from,MCH 20 Duct Leakage=Testing repquirements -Heating-only systems and Air Handler/Furnace changes do not require verification of Air Flow MCHC 23; nor Refrigerant Charge MECH 25 -Existing duct systems constructed insulated or sealed with asbestos are exempt from M(iH'�20 Dui*dakage Testing requirements. r k i E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diilond�150.2(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number: 215-A0158274A-000000000-0000 Registration Date/Time 2015-06-12 16:04:50 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-06-12 16:00:27 Schema Version: 0.5S5SDD STATE OF CALIFORNIA ALTERATIONS - HVAC CEC -CFIR- ALT -03 -E (Revised 06114) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R- ALT -03 -E Alterations - HVAC CZ 1, 3 to 7 and 16 (formerly CF-1R-ALT-HVAC) (Page 1 of 1) Site Address: Enforcement Agency: Date Prepared: Permit #: 161 5 fiml e I q. (I T Equipment Type Equipment Efficiency New: Ducting, Plenums, Lineset Conditioned Thermostat Required R -value Floor Area (sq ft) 13 Packaged System ❑ Coil AFUE COP R 6 (Q 1,3 -7) Ducts Served by system Setback QSplit System �Evaporator C3Condensing Unit SEER ❑ R -S' (CZ 16) Ducts J 00 sq ft (if not already HSPF ❑ R -6 (all CZ's) Plenums present must ❑ Furnace ❑ Lineset EER ❑ R -5 or R7.5 Lineset' be installed) HERS VERIFICATION SUMMARY Installer determines work to be completed and matches to one of the options below. At permit application this form is allowed to be filled out by hand. For final inspection all forms are to be registered (no hand filled forms allowed) and a copy left on site. ❑ 1. HVAC Changeout /Repair Required Compliance Documents to be left on site for Final: Can include new ducting All Equipment, CFI11- ALT -02 -E Condenser Unit, Evaporator Coil, CF2R: MECH -01, MECH -20 -HERS Air Handler /Furnace CF3R: MECH -20 -HERS Installer Requirement: Duct leakage (<.15% or, < 10% to outside, or seal all accessible leaks) Exempted from dud leakage testing if: ❑ 1. Dud system registered with HERS provider as previously sealed, or 112. There is less than 40 linear feet of dud in unconditioned space, or ❑ 3. Existing dud systems are constructed, insulated or sealed with asbestos (list manufacture date of building ❑ 2. New HVAC System Required Compliance Documents to be left on site for Final: All new equipment and All New Ducts' CFIR- ALT -02 -E CF2R- MECH -01, MECH -20 -HERS, MECH -22 -HERS, MECH -(23 or 24) -HERS CF3R- MECH -20 -HERS, MECH -22 -HERS, MECH -(23 or 24) -HERS2 Installer Requirement: Duct leakage < 6 %, Fan Efficacy (.58W /CFM), Air Flow >_ 350 CFM /ton (or Standards Table 150.0 -C / D alternative) ❑ 3. All New Duds with Replacement Required Compliance Documents to be left on site for Final: Includes replacing or installing All New CFIR- ALT -02 -E Ductsz and one or more of the following: CF2R- MECH -01, MECH -20 -HERS, MECH -(23 or 24) -HERS Condenser Unit, Evaporator Coil, Furnace CF3R- MECH -20 -HERS, MECH -(23 or 24) -HERS Installer Requirement: Duct leakage < 6 %, Air Flow_ 350 CFM /ton (or Standards Table 150.0 -C / D alternative) ❑ Exempted from duct leakage testing I existing duct systems are constructed, insulated or sealed with asbestos. ❑ 4. New Ducting over 40 feet Required Compliance Documents to be left on site for Final: Adding or replacing ducts in unconditioned CFIR- ALT -02 -E space but less than All New Ducts2 CF2R: MECH -20 -HERS CF3R: MECH -20 -HERS Installer Required to: Duct leakage (: 15% or, < 10% to outside, or seal all accessible leaks) ❑ Exempted from duct leakage testing I existing duct systems are constructed, insulated or sealed with asbestos. ' All new ducting R -8 required when more than 40 ft installed and R -6 when less than 40 ft installed. This includes in walls, between floors etc. : A New Duct system is when the duct system is constructed of at least 75 percent new duct material, and up to 25 percent may consist of reused parts from the dwelling unit's existing duct system (e.g., registers, grilles, boots, air handler, plenums, duct material. a R -5 (1" thick insulation) for linesets 1" and less. R -7.5 (1.5" thick insulation) for linesets over 1 inch. Most mfg will require Suction line Diameter with insulation as the following 1.5- 2T -2 % ", 2.5-3T-2%", 3.5 to 4T -2% ", 5T -4%" Contractor (Documentation Author's /Responsible Designer's Declaration Statement) I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the information on this document. 3. That the energy features and performance specifications for the design identified on this Certificate of Compliance conform to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations (CCR). 4. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the CCR. S. The building design features or system design features identified onthis Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit applicatio Responsible Designer Name: Responsible Des! ature: Date Signed: License: € c- P 1 1z '- 3 S 4q -Is-3 Company: Address: City /State/Zip: Phone: ° ERs ST /0 GlJod. LaNS UT �� -SQ 0 For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1- 800 - 772 -3300