Loading...
14100177 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 19927 BEEKMAN PL CONTRACTOR:SHAH RAJESH PERMIT NO: 14100177 OWNER'S NAME: CUPERTINO,CA 95014 PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL ❑ COMMERCIAL INSTALL(20)PANEL PV SYSTEM ON SFDWL ROOF TOP,4 License Class Lic.# KW Contractor Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$9000 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:31630137 00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITIIIN ERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS OM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the .v granting of this permit. Additionally,the applicant understands and will comply Issued by: Date: ZZ 01-1,4/1 with all non-point source regulations per the Cupertino Municipal Code,Section 9 18. RE-ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date I ereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) ,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE onstruct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections`25505,25533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: y Date-11D I ay; !� permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9 18. SignatureDate '�i 2� ab ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 (408)777-3228• FAX(408)777-3333•buildingCcDcupertino.org V\10� CUPERTINO 1 PROJECT ADDRESS q e e °(rn a n ,P I` � & � APN# � 16 — i�© — j e5 7 OWNERNAME STREET ADDRESS CITY, STATE,ZIP FAX 9 — 8✓e111ekma G�� �r6'.rio c �+ 9'SoI CONTACT NAME STREET ADDRESS CITY,STATE,ZIP FAX ?'0 ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME \ e V LICEIJSE NUMBER LICENSE TYPE BUS.LIC# - 4 7 COMP A NAME , E-MAIL FAX STRE T ADDRESS CITY,STATE,ZIP PHONE ?'_Z0 ^Ta ma T'-• I S It C O - 262 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF ❑ SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes ❑ No SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTSEG0hfNtERtTAt7M1r_Y): TOTAL C UUAOATION:O . O O DESCRIPTION OF WORK 0eY✓1 By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the prprefty owner's be I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. ee o comply with all applicable local ordinances and state laws relating to build' g construction. I authorize representatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent: � � Date: SUPPLEMENTAL INFORMATION REQUIRED - r OFFICE USE ONLY } ❑ OVER THE-COUNTER ' aI Imo" ,,:fl EXPRESS . _ q STA"tARD 5 U .a ti LARGE _ " PVApp_2011.doc revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 19927 beekman pi DATE: 10/29/2014 REVIEWED BY: Mendez APN: BP#: *VALUATION: 1$9,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RE USE: PERMIT TYPE: WORKinstall 20 ane/ pv system on sfdwl roof top, 4 kw SCOPE ' , '£-). Pt.r71 t.`rGL'/C Pf:t7771. PlfrYt t/7{;t'ti L ic't'. ,'}f lecrt. I �tFriG 1'ee.. PlctrnJ>. T'ernia Fee: I On"erPluinbInsp. {Jr'h�-r i<�c. fnup, Ahcx h, Irsq,). '°'a Phinlb. hap. 11ee. t,�t"ec.C t .£'1:e: NOTE: This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc. . These ees are based on the relimina information available and are only an estimate. Contact the De t or addn'1 in o. FEE ITEMS (Fee Resolution 11-053 Elf.' 7111131 FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 # Alternative Energy System Suppl. PC Fee: (j) Reg. ® OT 0.0 hrs $0.00 $236.00 IPHOTovRES I Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp.Fee: Reg. 0 OT0 0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 !<�t;2d,:ritttrdt;t'E' f'es�: 0 Work Without Permit? 0 Yes No $0.00 1 1 E) Advanced Planning Fee: $0.00 Select a Non-Residential Building or Structure 0 7)r�c=ti�aerat�atrea:a Fees: Building Strong Motion Fee: IBSEISMICR $1.17 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 �� r 31 $2.17 $236.00 ; TOTAL FEE: $238.17 . r Revised: 07/10/2014 OWNER-BUILDER DISCLOSURE FORM COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 CUPERTlNO (408)777-3228•FAX(408)777-3333•building(ftupertino.org Dear Property Owner(s): An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at: SITE ADDRESSI (� k7 Bee k ImCArt f. APN BP# OWNER nS4c.-I1�f!'oyt D, •a � VS.y S7+ern We are providing you with an Owner-Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner-Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed,and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION (DIRECTIONS:Please read and initial each statement below to signify you understand or verify this information.) °" 1. 1 understand a frequent practice of unlicensed persons is to have the property owner obtain an"Owner- Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. A 2. 1 understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. � 3. I understand as an"Owner-Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. t1;- 4. 1 understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. 5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. fEL6. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal government,withhold payroll taxes, provide workers'compensation disability insurance, and contribute to unemployment compensation for each"employee." I also understand my failure to abide by these laws may subject me to serious financial risk. R-';-7. 1 understand under California Contractors' State License Law, an Owner-Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. e�L8. I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s)that result from any latent construction defects in the workmanship or materials. OwnerBuilderForn2 2010.doc revised 04/14/10 9. 1 understand I may obtain more information regarding my obligations as an "employer"from the Internal Revenue Service,the United States Small Business Administration,the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. 1%-10. 1 am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the site address listed above. Nl.�) 11. 1 agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner-Builders as well as employers. 02. 1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the in ormation I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner-Builder and wish to hire Contractors,you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. CONSTRUCTION LENDING AGENCY (DIRECTIONS:Please complete the following construction lending agency information.) I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097 Civ.) Lender Name: Lender Address: Before a building permit can be issued,this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note:A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's si nature Property Owner's Signature: Date: ------------- -------------------------------------------------------------------------------------------------------------------------------- (NOTE: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner-Builder). AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner,the execution of which I understand is my personal responsibility, I hereby authorize the following person(s)to act as my agent(s)to apply for, sign, and file the documents necessary to obtain an Owner-Builder Permit for my project. Scope of Construction Project(or Description of Work): Project Location or Address: Name of Authorized Agent: Tel No Address of Authorized Agent: I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note:A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: OwnerBuildeYForm 2010.doc revised 04/14/10 „ ° Mi"W{ a gg Aft JR ON i * ,..k may.}� £ -c' •s ,zp r R_ 3 F ( k+ t1"e, _ Of 9 F � et � rs I r a "ref C ' 4 Q y t g 4 T [ �r y • f '� ss� #fie{���;3� S J t x k 3 f sY u 4r a vxsc .r^^Tf a+ ta..s-ri`s� `, a �a�tro z r ei s `�x, ...y .,t ^fi� 5�..t: '��`�i,.; �f ': -• ,.2.. '''�” �£i .l:K _ � ._(Yl�c`q':�F:. �8 g?. '�'7 �'� • �'�� . + SC,,, / S�, '405 To am rd lx 6 yX �L 2x6 plate to lagged into 4x 12 rafter with SS 5/ 16 lag bolt to be Chaulked foam roof cover block 4x12 2x6 anchor plate ' 2x6 V CUPERTINO j Building Department OCT 2 g 20% REVIEWED FOR CODE COMPLIANCE Reviewed By: C/= G Chapter 7 Solyndra Panel S ste CVP�RTa �en� '30 201t� • -� OCA 29 CCpe 7.1. Solyndra Panels & Mounts - ' REv� By- The Solyndra 200 Series Panel System is a tool-less panel installa�@gi tqi requiring no fasteners;it sim- ply snaps together.It consists only of Panels and Panel Mounts.The 200 Series Cable Management System simplifies wiring and requires no tools for assembly. Solyndra offers optional Snow Mounts. Figure 25 shows a six-panel system with Panel Mounts, optional Snow Mounts,and the Cable Management System. Figure 25. Solyndra Panel Mount System Panel Panel Snow Mount Mount ` Cable Trough Cab Clip le Trough Table 6 lists the standard hardware in the Solyndra system. Table 6. Panel Installation Hardware-Provided as Balance of System Item Model Number Description Panel SL200-)= Solyndra photovoltaic panel.-)OCX represents the power rating. Panel Mount SLM-230 Panel Mount for Solyndra 200 Series panel.(PN 0010-32767) E i Item Model Number Illustration Dust Cap for Male Solarlok Connectors 0048-30142 May be used to cover unused Solarlok male connectors. Dust Cap for Female Sol. ki 3t1 f43 May be used to cover unused Solarlok female connectors. 4 7690� J w k es V1.2 31 ()420 30102 r003 ential ri u. `7 Solyndra Panel Product Specifications Measured at Standard Test Conditions(STC)irradiance of1000W/mz, air mass 1.5 and cell temperature 25'C. 200 Series Electrical data D SL-200-182 SL-2191 SL-200-200 SL-200-210 SL-200-220 �- Power Rating(Pmp) WO 182 Wp 191 WP 200 Wp 210 Wp 220 Wp O Power Tolerance(%) %/Wp +/-4 +/-1 +/-4 +/-4 +/-4 Vmp Vohs 85.1 V 88.6V 91.7V 95.1 V , 98A V N ( Imp Amps 2.14 A 2.16 A 2.18 A 2.21 A 2.23 A i CL Voc Vohs 119.6V 122-8V 124.6V 1253 V 125.8 V Isc Amps 233 A 1234A 235 A 1236A 237 A O Q Temp.Coefficient ofVoc %rC -18 n Temp.Coefficient of tsc %rC -.02 't, Temp.Coefficient of Power %rC -38 1 "7 rD System Information =h Cell type Cylindrical CICS Mardmum System Voltage Universal design:1000 V OEC)&600V(UL)systems h O Dimensions Panel:2.28 in x 1.09 m x 0.06 m;Height 036 in to top of panel on mounts Z) IA Mounts Non-penetrating,steel-reinforced,high-performance engineered plastic Connectors 47yco Solarlok-;0.20 m cable Series Fuse Rating 124.4 Amps Roof Load 13.9 k9/m2(2.8 Ib/ft2)panel and mounts Panel Weight 31.8 k9(69 lb)without mounts Snow Load Maximum 1850"Pa/1200 Pa(38.6 Ib/ft2/25.1 Ib/ft) Hailstone Impact 25 mm,753 g at 23 m/s per IEC 61646 ;Wind Performance 208 km/h(130 mph)mardmum.Self-ballasting with no attachments jOperating and Storage Temperature -WC to+85'C NOCT 44 C at 800 W/m,Temp=20'C,Wind=1 m/s Certifications/L istings UL1703,IEC 61646,IEC 61730,Protection Class II)l Application Class A per IEC 61730-2,Fre Class C,CE Mark,CEC listing,MCS/BRE(UK) Warranty 25 year limited power warranty;5 year limited product warranty Specifications are subject to change without notice.Specfication is only valid when using the product in accordance with Solyndra's design and installation guidelines using Solyndra supplied mounting and interconnecting hardware. The electrical characteristics are within t10 percent of the indicated values of Isc and Voc under standard test conditions(irradiance of 100 mW/cm2,AM 1.5 spectrum,and a cell temperature of 25°C(77'F)). *1850 Pa snow rating requires optional Snow Mount. P aoq GO 0� NI- e4\ R eyed$y. FZ NO, r�.p 1" W' { 0920-30031-004 �c)ential A _ Senes 7 l Conduit Placement and Roof Surface Wiring Wires running from the array to the combiner boxes and/or the inverter should be raised above the roof surface in a way that does not allow water to form ponds behind the wiring supports. 2.6. Grounding Solyndra 200 Series Panels and mounts meet the requirements for IEC Protecti�C��I •not nec- essary to ground the array,or to ground any particular lead of the array at d1Z ei!-ra ess required by code)when installing a Solyndra system. `�1t� The glass construction and hermetic seals used in the c f each Sol #1b'dule do �*w for current leakage or place high potential near low potenn pare foot sus ec �e o en }al- Induced Degradation(PID)or other corrosion damage offsets witect toolyn- dra panels may be operated with transformerless inverters �O�k .e.4e d6`1 2.7. gray Installation around_Li htning Grids Some rooftops are fitted with a lightning grid.A lightning grid is an array of wires running horizontally in both directions across a roof.Dimensions vary,but typically the wires are spaced a few meters apart,and the entire grid is carefully grounded to earth.These grids are occasionally fitted with vertical conductors called air terminals,or`lightning rods'. A Solyndra system,when installed, may be placed over a lightning grid. Certain guidelines must be fol- lowed, but Solyndra panels do not impact the function of lightning systems or make the building more likely to have a lightning event. Array Placement Guidelines with Lightning Grids 1. " Engineering for a photovoltaic system on roofs with lightning grids requires obtaining the S dimen- sion required by code,either from the original designer or by re-calculating it.The S dimension is the minimum separation distance from the lightning grid required if additional precautions are not taken. 2. If panels are to be installed within distance S of the lightning grid components there are certain ap- plicable electrical code requirements.These may include a requirement to connect exposed metal com- ponents to the lightning grid and a recommendation that conductors coming into the building be protected by voltage shunt devices. 3. Solyndra 200 Series Panels and mounts are IEC certified Class H devices.They are not considered to have exposed metal parts and therefore do not have a requirement to he attached to the lightning grid, even if placed within the S distance. 4. Because Solyndra 200 Series Panels are IEC certified Class H devices, voltage shunt devices are not required,but are recommended,for building lead-ins and inverter protection.Use of such devices is a design;decision that should be based on sensitivity of building use,or an inverter protection risk versus cost analysis. 5. Solyndra panels should never be placed over air terminals.Any air terminals that are under the array must,be moved. 6. 1Iodfyng the lightning protection system to protect the Solyndra array is not necessary. ME,,� r s F . _ pp fFBk".j�Rh^1 2 12 L7 ;._ ` `bra LLC 47488 Kato Road Fremont CA 94538-, '- 3- • A PV Inverter ��P oepa SUNNY BOY Also S 1A 3000TL--US / 3800TL--UStig�'® 4000TL--US / 5000TL--US j 6000TL-US Installation Manuale�ed BMW Zvi Fss W 4 l x �, r'3W U §�, 1 4 X31{yZ 4. F" ; 'ky �l r i; _ *yy3tzrN`.4w. h 1 iTr is�4izjS4�'s'✓f _ "}X,'nkkv A'r 9 f- a l SB3-5TLUS224Aen-15 Version 1.5 (DCD Efficiency care SUNWY BOv4tX10US i Accessories 98 85485 irertoae Blt,PiggyBodc 485USFBM BIPBINV-TPOINNR 96 Oil2alT`•H wih 5dsmiAWl STPBWANT i� s, t92 '` y, 955 i:. '. Coin6i5widr- Combb.Box DC&xomaaad w S.Ptiy wu:g foF added — eoN sasorq ° $ urayaoat:eer6ox oa,w:nrceodsdery BvN–310h'i.`3 a, - COMBOSIMfCti SBC66MWSBCS" E ro IV.–4BOV)' aso :.NI ? - - 0.0 02 OA 04 -OA - t9 ri. OuWp—/R-dpower Technical data Sunny Bay 3000-W Stymy Boy 380011S Sunny Boy 40006US 208 V AC 240 V AC 240 V AC 208 V AC 240 V AC Input(DC) Max usable PV power f @ module STC) 3750 W 4750 W 4375 W 5000 W Max DC power(@ toss V-1) 3200 W 4200 W 4200 W Max.DC voltage 500 V 600 V 600 V DC nominal voltage 250 V 310V 310V MPP voltage range 175-400V 200-400V 250-480V 220-490V 250-48DV Min.DCvoltage/smrtvnhoge 175/228V 2Do/228V 250/285V 22D/285V 250/285V Marc.input—red/per Ong:(cdDG&owmed) 17A/17A, 18A/I8A, 18A/18A, 36 A @ combined muninal 36 A @ combined iermin" 36 A @ combined terminal Number of MPP trackers/Tised strings per MPP bodwr 1/4(DC disconnect) Output(AC) AC nominal power GQ ��3000 W 3800 W 35W W 400DW o Max AC apparent power t��P V`_epdt 3000 VA 3800 VA 3500 VA 4000 VA Namfaa(AC wbage/adze ' dm90 208V/0 24o V/0 240 V/- 208 V/• 24O V/. o AC voltage range � U�� 183-229V 211-264V 211-264V 183-229V 211-264V N AC god frequency,range 60 Hz;59.3-60.5 Hz 60 Hr 59.3-60.5 Hz 60 Hz;59.3-605 Hz N MWLOutput CWTTen /Q�G`G 13A 16A 1iA Power u Phase conductors/connecKon 0 ` o�coo (/y�i�, 1/2 1/2 0 HarmonicsGQ ��96.00DX<4% <4% <4%MaxeHidency �� - 9650% 96.80% 96.50% 96.80%CEC < Proteefficiencyction devices RE�� e J`eea�y 95-00% 95.50x 96_00% 95.50% 96.00% DC rrpoiarity potectio„ _ • • e "o t arch o 0 0 a ACshortcircuit protection • • • '- Galvanically isolused/all-pole sensitive monilming unit •% •% •% o Pratxfionclass/&MrVallage category 1/BI 1/111 1/BI = General data o E DfinensiDnS(W/H/D)in mro(iO) 450/350/235 (18/14/91 DCDboomrectd'mreneKm[WY/H/0)i�mm.0n) 187/297/190 (7/12/7.5) <` Paderg dimensions(W/H/D)in mM(;o) 390/580/470 (15/23/18.5) DC Disconnect pac6ng dimensions(W/H/D)in mm tar) 370/240/280 (15/9/11) - WeigM/DC Di%=umdweiglit 38 lig(84 lb)/3.5 kg (8 Ib) a Paddrg weigh/DC Discomectpad g 44 kg (971b)/4 kg (91b) Operofe V temperature rage Oul Fower)` -25-C...+45"C (-13-F_.+113"F) -- Noaeemersion(typical) 40'dB(A) 37 dB(A) 37 da(A) Internal consumpfion at right 0;1 W 0.1 W 0.1 W Topology [F transformer IF transformer IF transformer Cooling concept OP0004 Op5Co01 Op" - fledronics protection rafeg/connection area NEMA 311 NEMA 3R NEMA 3R/NEMA 3R NEMA 3R/NEMA 3R a Features Daplay_text One/graphic •% •% •% _ Imedaoes.RS485/Mudooth" 0/0 0/0 0/0 Watraray_10/15/20 years 0/0/0 0/0/0 0/0/0 Certificates and permits(moreovola 6onrequest) W741(secomfEd),u1998,U1.16996,IEEE 1547,FCC Pbd 15fCkWA&Bj,C54C222No.107.12001 Integmded GFDI • • • a`o For AFCI functiionatdy or extended operafi ie ire nxW to-40'"C specdy.SBXXXXUSI2 when ordering. o° •Standard features o Opfiond feaArues -Not available Dara at rwrnina)oored'Aiars NOTE US inverters slap with gray ltds z V- Type designation SB 3000US 583800-US-10 SB 4000US Toll Free+1 888 4 SMA USA www.SMA America.com SMA America, LLC r Solyndra 200 watt Solar module(20) 4.0 kw PV Sys 200 amp main service • 4 wired In series 5 strings of 4 to be combined INVERTER MAN. and model SMA 4000 max DC volt 600v max power640c 5000w nominal DC voltage 310 Max AC current 17amps max ocpd rating -neg - neg D JELOPMENT DEPARTMENrr -neg Irrevers(bia 'GRWNG DiNASION-CUPERTINO CSD Combiner Bo This ;::s and specifications MUST be kept at the Inverter - neg job si , r const action. It is unlawful to make any SMA—SBCTL 6-10 cm.y,: r: ur a;tc ations cn same, or to devief' Combiner Box �__ tlher;', _ fi'on the f;uilding 0, ,Jal. 15 amp fuses -neg cY t, Man and s::!�ifi,^.-scions S I ! .T 20am�;240 IS Source currentconductor --- cid conductor size #12 awg SMA 4000 . PV wire cable 100 amp sub-panel -- TL Inverter F Irreversible GRD GRD WARNING onductor SYSTEM VOLTAGE AND CURRENT Max Power-point current(IMP) 10.9 ELECTRIC SHOCK HAZARD #8 THWN in 3/4 EMT Max Power-point Voltage(Vmp) 380.4 DO NOT TOUCH TERMINALS OPEN CIRCUIT VOLTAGE(VOC) 498.4 VDC pLOT p.LpNS TERMINALS ON BOTH THE LINE AND PV modules @STC SHORT C I R C I S C) 2.35 GHPGKED 8Y LOAD SIDES MAY BE ENERGIZED manufacturer Solyndra modI� IN THE OPEN POSITION max elPPLcurrrent2.18 � NksoqePaT200 jurv 1)06 max PP voltage 91.7 N� DVPT PHOTOVOLTAIC DISCONNECT VOC 2.18 amp .\ Is ��`a INGE /, ISC 2.35 .E AC� max pow DA,TG max sys evolt ge0498.4 �p AOR CvF F I E COPY R[,DG• DH,PT �ev`e,Ne ��� � Ra�iesh Shah 19927 Beckman Place Cupertino,Ca. 95014 412 Eft o.c. Gtyp) Eichler Post and beam with 2x6 roof under layment approx 210 eq ft panels with a f o a m roof Module wt 2.8 lbs per sq ft 24f t approx 210 eq ft pan Is �. 3/4 EMT 3f t clearance all sides Comb er Box I I comf orms to NEC 690 &250 52.5 Load distribution foot I00 24ft no Roof penetration required 3/4 EMT �. i 3/4 E home run I window clear T 103 eq ft P�R�\AO fit. `a�Q�eoa Inverter Placed below GOO? O �v�N G .' 44ft ``/f FOR GC��// REv� Rev�e�ea B`1- wall on entrance way I � I 40 I p 5 200 amp main service - ro L.——— 100 amp sub panel Disconnect Ra' esh Shah 19927 Beckman Place Cupertino,Ca. 95014