Loading...
14010151 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 11775 RIDGE CREEK CT CONTRACTOR:GREENTECH ELECTRIC PERMIT NO:14010151 12333 SARATOGA SUNNYVALE RD DATE ISSUED:01/28/2014 OWNER'S NAME: SARATOGA,CA 95070 11 [V--' LICENSED CONTRACTOR'S DECLARATION JOB DESCRH'TION: RESIDENTIAL[] COMMERCIAL �Z) g ,g3t� INSTALL EVC STATION IN GARAGE 9000 KW License Class Lic.# Contractor Date 4 � I hereby of r in that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the Valuation:$800 p rformance of the work for which this permit is issued. Sq.Ft Floor Area: JVhave and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:36604046.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITEIN 1 OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS ROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, 1.28'14 ,��'1 , costs,and expenses which may accrue against said City in consequence of the Issued by: Date: �T granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section 918. RE-ROOFS: Signature Date 02 41 All roofs shall be inspected prior to any roofing material being installed.If a roof is V installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Date: Signature of Applicant: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the roe y g HAZARDOUS MATERIALS DISCLOSURE property,rty,am exclusive) contracting with licensed contractors to construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for bythe Health&Safety Code,Sections 255 ,2�and 25534. � Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agen Date: permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If,after making this certificate of exemption,I become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 918. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION \� 10300 TORRE AVENUE•CUPERTINO,CA 950143255 \� CUP ERTIN0 (408)777-3228•FAX(408)777-3333•building0cuper ino.org Is PROJEcT ADDRESS 11-775 R I DCS E CREEK C. "r''e ' ( STREETADDRESS //775 R'CO E CKEF-KOf"ITY.STALE.ZR' �fU PE R TIN® FAX ME CONTACT NA ,� /� PHOM E-MAIL: S PMT ADDRESS CITY,STATE,ZIP FAX ❑OWNER ❑ OWNER-auumfm ❑owmm Amw COMIRACTOR ❑COMRACTDRAOEM ❑ ARcm-mcT ❑ENOUIFm ❑ DEVELOPER ❑mmANT comEtACTONM � �50W-T "� / ��1AVU�L CQIV Bus-L'" 322— Sp CoMNYNME GREEN TEM FLW—TRIG F MAm FAX SIREr:T waDREss / 3 SSA J�T11 ,a M NYV Lir,STATE" sA RA'TGC--,A C4 '%,S),280-1180 ARCH=C 1WGE,IEER NAME Lif�+NSE NUINBER BUS LIC/ COMPANY NAME E-MAX FAX STREET ADDRESS QTY,S/•ATE,ZIP PHONE USE OF O(SFD or Duplex ❑ Muhl-Family PROmm IN WILDLANDPRo]E\cr IN STRUCTURE ❑ Comnmercial URBAN rEiRFACE AREA ❑ Yes ❑ No FLOW . ❑ Yes ❑ No ❑SOLAR PANELS ELECTRIC vmcm CBARam s Im mN E SOLAR WATER MATING ❑ OTHm FOR SOLA PANELS NUMBER OF PA�N-ELS/U M: / KQ.OWATTS(COi RCIAL ONLY}.�Oo TOTAL VALUATION: DESCRII''I'!ON OF WORK /A'S/ A J ) A T I O Al OF jEVSE //V &A R ACS E t CJ i By my signature below,I certify to each of the followbW I am the property owner.or authorized agent to act on the f.-I have read this - application and the information I have provided is conwt. I have read the Dperipdon of Work aml verify it is accinum. I agree to comply with all applicable local ordinances and state laws relating of Cupertino to enter the above-ii lifted{xo rly for n purposes. Signature of Applicant/Ageat: Date: SLTPLEMENrAL WORMATION REQUIRED PYApp 201 Ldoc revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR—BUILDING DIVISION ADDRESS: 11775 ridge creek ct DATE: 01/28/2014 REVIEWED BY: Mendez APN: I BP#: "VALUATION: $800 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration/ Repair PRIMARY SFD or Du 12X PENTAMATION SOLAR-RES USE: p PERMIT TYPE: i WORK install evc station in ara e SCOPE 01 'x Mr� /tech. Plan Check Plumb. Plan Check Elec,Plan Check ilech.Permit Fee: Plumb.Permit Fee: Elec.Permit Fee: F1,f,/', ;�1ech.Insp. Other Plumb Insp. EIF-1- Other Glee.Insp. .Insp.Fee: Plumb. Irrsp.Fee: Elec.Insp. Fee: NOTE: This estimate does not'include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc). These fees are based on the prelimina information available and are onjE an estimate. Contact the De t or addn'l info. FEE ITEMS (Fee Resolution 11-053 E . 7/1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = # Alternative Energy System Suppl. PC Fee: (E) Reg. Q OT F6.o hrs $0.00 $106.00 1CHRGSTA EV Charging Station PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee-.0 Reg. ® OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Cctnsli-rtction Tax: Adinini.strative -ee: Work Without Permit? ® Yes No $0.00 Advanced Planning Fee. $0.00 Select a Non-Residential Building or Structure Travel Documentation-Fees: Strong Motion Fee: IBSEISMICR $0.50 Select an Administrative Item Bldiz Stds Commission Fee: 1BCBSC $1.00 $1.50 $106.00 � o $1 Revised: 01/15/2014 LIVING SPACE r BRINDA SHAH 11775 RIDGE CREEK COURT CUPERTINO,CA 95014 EXISTING LAUNDRY ROOM SCOPE OF WORK:Install(1)40 AMP 240 VOLT circuit breaker in existing EXISTING 100 AMP 3/4"EMT 100 AMP subpanei located in the laundry room.install 3/4"EMTzonduit RECESSED Sk16PANEL CONDUIT from subpanel to wall mounted charging dock,Conduit will be mounted to existing surfaces of the laundry room wall.Charging dock will be mounted to existing wall surfaces inside the garage. Cv v;','!;; -e'r 11_V7 OP;,i'',ENT DEPARTMENT EYSE•RS INSTALLLOCATlt1N L.,;LL9.VU ei!L'i:�i .i•d-CUPER T INO r9 26 t c�r•'.�..A�no snA^it'�cations MUST be kept at the 2D' t .(i _ . Jtt is ujj :a .;`u!to make any onI same,or to deviate 3-CAR GARAGE SPACE ;_ iJ_• I t ;1i1 the Build?ng Off 1c1al. n=<;' -n ¢i~"ations SHALL NOT riloval ol-the violation Jianie or S oata Law. EXISTING 125 MAIN l SERVICE PANEL .144h DRIVEWAY CUPERTINO Lry l.IMin DePRrtment ���� 2 8 20 fr'w4 P Ai4Z� REVIEW`— FOR CODE COMPLIANCE C RECRED By Reviewed By. .��° i)t',TE . 0 IF. .00-011 OATS �' -- C:1 AM Ask 2011 AeroVironment, Inc. All rights reserved V-4 Q > This guide is a reference for Municipalities inquiring about the use, installation and compliance of the AeroVironment EVSE-RS with the National Electric Code and Local Codes. AeroVironment, Inc. Model EVSE-RS Product and Installation Overview The EVSE-RS is a device which offers a simple and safe way of providing electricity to the on-board charger in an Electric Vehicle. NEC 625 Compliance • 625.2 Definitions. • Personnel Protection System:A system of personnel protection devices and constructional features that when used together provide protection against electric shock of personnel. • 625.5 Listed or Labeled: UL Listed 2594 • 625.9 Electric Vehicle Coupler: J1772 coupler SAE North American standard • 625.13 Electric Vehicle Supply Equipment: Permanently connected and fastened in • Place. No exposed live parts • 625.14 Rating: 30 amp output rating. Continuous load • 625.15 Markings: — (A) For Electric Vehicle Use Only(Denoted on EVSE-RS Label) — (B)Ventilation not required (Denoted on EVSE-RS Label) • 625.16 Means of Coupling: Conductive J1772 connector and EVT rated cable • 625.17 Cable: EVT rated cable extra heavy usage • 625.18 Interlock: Proximity switch de-energizes when unplugged • 625.19 Automatic De-Energization of Cable: Cable break away feature. • 625.21 Over current Protection: Shall be sized for continuous duty 125 %-40A Circuit Breaker • 625.22 Personnel Protection System: Proximity switch, GFI protection, Breakaway cable, Trouble annunciation light for faults and NEMA 3 Rain Tight enclosure. • 625.23 Disconnecting Means: For electric vehicle supply • equipment rated more than 60 amperes or more than 150 • volts to ground,the disconnecting means shall be provided • and installed in a readily accessible location. • 625.25 Loss of Primary Source: Contactor opens upon loss of power. r INSTALLING THE EVSE-RS Specifications: ■ For use with Electric Vehicles ■ Ventilation not required ■ NEMA Type 3 Rain Tight enclosure ■40 Amp. circuit breaker rating. Do NOT use a Class A circuit breaker with the EVSE-RS Charging Dock. Number of Freq Hz Voltage AC Current Operating Phases Amps Temp 19 N Power Disconnect switch Charging Dock distribution (i#applicable) panel wall stud T 1 . Choose wire entry location HOLE IN REAR OF HOLE ON UNDERSIDE OF CHARGING DOCK CHARGING DOCK Al \, til,U Bottom View ' Rear View 2. Attach the mounting plate Mounting plate p 0 Large hole for conduit utility wires a Smail holes for Charging Dock mounting holes mounting plate to wall stud O Flat�washer Lag bolt Wall stud - ~J O0f----- ------ ------ ------- 4 48- O Wall stud 3. Attach the Charging Dock to the mounting plate a. Torque the screw to 40 in/Ib. Upper mounting hole Flat washer Socket head screw � -Z y'k a. 4. Wire the Charging Dock a. Torque the terminal block screws to 20 in/Ib. b. Torque the Grounding Strip screws to 20 in/Ib. Terminal Block s Ground Strip Ground Wirer Two power wires 5. Install the front cover #10 Torx screws—Torque 12in/Ib t fr 4M r Removing the trim ring A'�iGf'� � lYiO 1 11 Access hole : Outer ring 6. Complete the installation ~ a c o - --------- a RON t FRONT PANEL COMPONENTS The charging dock is r€celuircg AC pavier. START READY TO CHARGE Press to begin a charge.The P%,,charging dock is ready to POWERFRESEW oPONER ESR ESE NT and READY ;; charge orcharg ng is paused. READY TOCHARG€o G S RT €T CHARGEicthts rnuctbe on. 4 TROUBLE 0 VO4KIE CONNECTED STOP TheconnectorI n properly Prsmtomenuafly stop char inrg. connected to the vehicle port The devicegill stap aLAornaticaliv or the chaiga is complete. when it reaches full charge. VEHICLE CHARGING The vehicle is baing charged: TROUBLE Tbere is aii Griot Try rerrKwing the connector and insetting back into ttie vehicle.If Trouble Indicator is still ilturninated rail _.. Customer Servire at 1(877)lam GAS EV or 1(87 t)554-2738 or v-sit Customs,'Service can the RELCJL4E BUTTONga batsa .n steno=a.ccinlieaf. Press to releasethcConnector frarn the charging d Y_k or the cehide part. `. In s,. CHARGING THE VEHICLE Pmss the buttm on taxa €.trrvr the cable frm o,rnnoctcf to r€ sem.it ammd ft.cables hanger, m the n:tiwpq dwk VEMCLECONNECTED•• arNar hw—vt�nr""ctxfirmlyiritvthQ arae eas p els will begin "er,fdg churcie F_4t.vvfhol <urtoinatic«lE;g+<When ting€nserf�i:tha"v;Ji�",(.E a€�xxnrwe3s+u 8 ch�igiru� &g€ns,the. % c`14ECTEDliltinnthe e O VEHICLECHAlGINC�light cP ing dock w'1 io urremata. €1 begin blink.Thera is no riegd to prssn START. vEMeLE ctutNG • OvrAKr Charring Wilt stag eutorn timN Whin thu VEHICLE STOP When omplete. "fou ti an manually CHARUNG light strop;.^ stop dording by pre'ssing STOP, blinlang on the charger, When thq READY TO CHARGE press the button care the light blinks,ramove the conm;4ctrw cor nE ctor to release. from the vehicle charge port.If Nell to rer iov€i from, you have "ed 910P,you can whi'cle charge purl. press START to resume charging. AM RillPf i A, 102 0 • f f x ' f � M � 'CS des fheY ' rr'yd B 4 � c�u F TC # T 6 _.' MA i Mtilt � 1 aven�en�l fti � "'AN \• Electnclans w1#1'- r zaOe �- to x � � n The EVSE-RS Charging Station charges all SAE J1772-compliant vehicles—including both electric vehicle(EV)and plug-in hybrid (PHEV)models—in the convenience of the home garage,workplace, condominium,apartment,or retail parking structure.The Home SPECIFICATION EVSE-RS Charging Station safely and reliably delivers AC power to the Connector SAE J1772 compliant vehicle's on-board charger and features a weather-resistantVE(I� Ra .... . >; f Voltage 208VAC to 240VACc� la6�a�1s . Frequency 60/50Hz The EV Charging Station can be installed by one of our independent Output Current 30A max certified licensed electricians who also facilitate necessary permitting Input Current 40A max and inspection,and provide information about EVSE-RS use to the Operating Temperature 22°F to 1221F customer.An optional module is available to enable WiFi,Zigbee,or -30°C to 50 C cellular network connectivity. _................... _..... Storage/Transit Temperature -40°F to 140°F -40°C to 60°C Relative Humidity Up to 95/0 non-condensing Dimensions 12"x 12 x 8" (approximate) Weight 10 lbs.(excl.cable) ........ Cord Length Up to 25'available 'p Regulatory Co1­11111111111 "1mpliance UL,cUL,C11111-_111_1______...-1_11E ick CrUL C V listed C E Information and specifications subject to change. -' «" V...._._. "Installation services available in certain areas, contactAV for additional information. 02011 AeroVironment,Inc. 15_01 11_I 0147