Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13050127
CITY OF CUPERTINO BUILDING PERMIT I BUILDING ADDRESS: 10620 MADRID RD OWNER'S NAME: XIAODONG ZHAO OWNER'S PHONE: 4083061132 ❑ LICENSED CONTRACTOR'S DECLARATION r.e.se Class_ Lic. # M Ic 1 j Contractor dLXl- 4Mg&AL0 Dates' �I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business &Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all n�o -pnull.soouurce regulations per. the Cupertino Municipal Code, Section 9.18/ 1 , -,- Date L ❑ OWrTER- BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: I have and will maintain a Certificate of Consent to self- insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I 'shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions.or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date CONTRACTOR:SOLARCITY 3055 CLEARVIEW WAY SAN MATEO, CA 94402 JOB DESCRIPTION: RESIDENTIAL PERMIT NO: 13050127 DATE ISSUED: 05 /16/2013 PHONE NO: (650) 638 -1028 COMMERCIAL INSTALL 22 ROOF TOP FLUSH MOUNTED SOLAR PANELS 5.37 KW Sq. Ft Floor Area: Valuation: $22000 APN Number: 35608042.00 1 Occupancy Type: PERMIT EXPIltES IF WORK IS NOT STARTED WITI8AYS OF PERMIT ISSUANCE OR 180 DAP WOM LAST CALLED INSPECTION. Issued by: Date: 15-1/&- ["1 RE- ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the ertino 1 Code, Chapter 9.12 and the Health & Safety Co d;,-8 ctions 2550 33, a25534. Owner or authorized CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT •BUILDING DIVISION \ 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 AE (408) 777 -3228 • FAX (408) 777 -3333 • buildinq(cDcupertinc.org CUPERTINO ! PROJECT ADDRESS 'L °N U b I D /q r (J , , OWNERNAME X \ E -MALI, I STREET D S' CITY TA F.AX 4 CONTACT NAME PHO E-MAIL STREET ADDRESS CITY. STATE, ZIP FAX ❑ OWNER ❑ OWNER- BUILDER ❑ OWNER AGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ .ARCHrrECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME - LICENSE NUMBER O LICENSE TYPE f I / BUS. L/It� x a j�L� COMPANYNAME E / LQ W Al j 1 i/� d -G1 1 STREET ADDRES S J -^ l r 7'Uf CITY TE, 1 �� /O 7 P t� ARCFUTECT/ENGINEER NAME LICENSE NUMBER i BUS. LIC k COMPANY NAME E -MAIL FAX STREET ADDRESS - CITY, STATE, ZIP I PHONE USE OF SFD or Duplex ❑ Multi - Family PROJECT IN WILDLAND PROJECT IN ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes U NO STRUCTURE: SOLAR PANELS T-C3ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HE ❑ OTHER: F RSOLAR PANELS: NUMBER OF PANELSAfNrrS. KILOWATTS TOTAL VALL'ATi DESCRIPTION OF WORK RECEIVED I . By my signature below, I certify to each of the following: I a rty wrier or authorized a nt :o act on the to owner's behalf. I have read this application and the information I have rovid is correct. I h scnpnon .f Worl�a verify it is accurate agree to comply with all applicable local Ordinances and state laws relating to ildin onstruction. I a sent tives of upeit to enter the a�l ent� d property for insp purposes. L Signature of ApplicantlAgenr. Date: ,�/j Sttp LEMENTAL INF TION REQUIRED o usEOnlY OVER -THE- COUNTER - y F ;G 1 - EXPRESS - ' U _ - ❑ STANDARD U S- LARGE _ a ❑ MAJOR PVApp_201 Ldoc revised 03116111 VK47. JOB ADDRESS: PERMIT #�: OWNER'S NAME: i �. lil PHONE #.� GENERAL CONTRACTOR- BUSINESS-ZXCETSE.�# ADDRESS: ^° CITY /ZIPCCF�, k A 4 *Our municipal code requires all busi�iesses working in the city to have a City of Cupertino busines5tlicense.' ' NO BUILDING FINAL OR FINAL. OCCUPANCY 'INSPECTION(S) WILL B SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONT CTORS HAVE OB AThTED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Ste ature Date Please check applicable subcontractors and comp the following information' Y ,�L SUBCONTRACTOR BUSINESS NAME SINESS LICENSE # Cabinets & Millwork rh ` Cement Finishing Electrical Excavation Fencing Flooring / Carpeting Linoleum / Wood Glass / Glazing Heating Insulation Landscaping Lathing Masonry Painting / Wallpaper Paving Plastering s Plumbing Roofing ' Septic Tank Sheet Metal Sheet Rock Tile / Date Contractor Signature ABBREVIATIONS ELECTRICAL NOTES INDEX LICENSE JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET CA # 888104 FLASHING WILL BE PAINTED TO MATCH AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN PV2 SITE PLAN C -46, C -10 EXTERIOR BLDG BUILDING POSITION, A SIGN WILL BE PROVIDED WARNING PV3 STRUCTURAL VIEWS CONC CONCRETE OF THE HAZARDS PER ART. 690.17. PV4 PV5 STRUCTURAL VIEWS UPLIFT CALCULATIONS Installing 9 22 —roof top C COMBINER BOX 2. EACH UNGROUNDED CONDUCTOR OF THE D DISTRIBUTION PANEL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PV6 THREE LINE DIAGRAM flush— mounted panels r5.39kW) l P J DC DIRECT CURRENT BY PHASE AND SYSTEM PER ART. 210.5. PV7 ELECTRICAL CALCULATIONS EGC EQUIPMENT GROUNDING CONDUCTOR 3. A NATIONALLY - RECOGNIZED TESTING CUTSHEETS ATTACHED APN: 356 -08 -042 (E) EXISTING LABORATORY SHALL LIST ALL EQUIPMENT IN EMT ELECTRICAL METALLIC TUBING COMPLIANCE WITH ART. 110.3. G SOLAR GUARD METER 4. CIRCUITS OVER 250V TO GROUND SHALL CUPERTINO GALV GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) GEC GROUNDING ELECTRODE CONDUCTOR 5. DC CONDUCTORS EITHER DO NOT ENTER Building Department GENERAL NOTES GND GROUND RUN IN RACEWAYS HDG HOT DIPPED GALVANIZED OR HE FIRST ACCESSIBLE %IAY 16 2013 I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN 1. THIS SYSTEM IS GRID - INTERTIED VIA A PLOT p LANg EVIEWED FOR CODE COMPLIANCE INVS INVERTERS RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 2. UL- LISTED POWER- CONDITIONING INVERTER. THIS SYSTEM HAS NO BATTERIES, NO UPS. CHECICF B.y Isc SHORT CIRCUIT CURRENT -D Reviewed By kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE 3. PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AND D`4�'E ��6 kW KILOWATT UL- LISTED LOCATION PROVIDED BY THE INVERTER INPUT CIRCUIT ARE UNGROUNDED. /3 LBW LOAD BEARING WALL MANUFACTURER USING UL LISTED GROUNDING 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED MIN MINIMUM HARDWARE. 5. ALL WORK TO BE DONE TO 2010 CALIFORNIA PL COMMUNITY DEVELOPMENT ENT MIR MIRROR 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, BUILDING CODE. G DEPT UPEPART (N) NEW RAIL, BOXES, ETC.) SHALL BE GROUNDED USING 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE APPROVED NEC NATIONAL ELECTRIC CODE UL LISTED LAY -IN LUGS LISTED FOR THE 2008 NATIONAL ELECTRIC CODE AS AMENDED BY This set of plans and specifications MUST be kept at the NIC NOT IN CONTRACT PURPOSE. POSTS SHALL BE MADE THE 2010 CALIFORNIA ELECTRIC CODE . BLDG, job site during construction. It is unlawful to make an NTS NOT TO SCALE ELECTRICALLY CONTINUOUS WITH ATTACHED Dg changes or alterations on same, or to deviate OC ON CENTER RAIL. therefrom, without approval from the Building Official. P PANEL BOARD 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE PL PROPERTY LINES BONDED WITH EQUIPMENT GROUND CONDUCTORS The Stamping of this plan and specifications SHALL NOT PV PHOTOVOLTAIC AND GROUNDED AT THE MAIN ELECTRIC PANEL. be held to permit or to be an approval of the violation VICINITY MAP PVC POLYVINYL CHLORIDE 10. THE DC GROUNDING ELECTRODE CONDUCTOR Of anv-Drovisions of any City Ordinance or State Law. S SUBPANEL SHALL BE SIZED ACCORDING TO ART. SCH SCHEDULE 250.166(B) & 690.47. BY , • • - - SS STAINLESS STEEL r. DATE 3 SSD SEE STRUCTURAL DRAWINGS NO. 1 STC STANDARD TESTING CONDITIONS = '' SWH SOLAR WATER HEATER _ r • TYP TYPICAL ,:.. UON UPS UNLESS OTHERWISE NOTED UNINTERRUPTIBLE POWER SUPPLY, r _- V VOLT }. Vmp VOC VOLTAGE AT MAX POWER VOLTAGE AT OPEN CIRCUIT 0 F F I C 0 NO W WATT µ 3 NEMA 3R, RAINTIGHT REV BY DATE COMMENTS • I REV A NAME 5/6/2013 COMMENTS CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT USED FOR THE JOB NUMBER: J B- 9501738 00 PREMISE OWNER: AHJ: Cupertino DESCRIPTION: ZHAO, XIAODONG ZHAO RESIDENCE DESIGN: MWALK -� ►�. �- - MARKET: RESI MODULES: 22 TRINA SOLAR TSM- 245PC05 PA05. BENEFIT OF ANYONE NOR SHALL IT ' PART TO OTHERS E EXCEPT SOLMOLE INC., BE DISCLOSED IN WHOLE OR IN OUTSIDE THE RECIPIENT'S 8 10620 MADRID RD 5,39 KW PV Array y 'I', S ol�rc't &AW /_ r /W. PROJECT MANAGER: MOUNTING SYSTEM: ORGANIZATION, EXCEPT IN CONNEC11ON WITH C U P E R TI N O, CA 95014 3055 Clear iew9�2Son Mateo, CA THE SALE AND USE OF THE RESPECTIVE Comp Mount Type C SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCIIY INC. S -US PAGE NAME: 4O8 306 -1132 COVER SHEET SHEET: PV 1 REV: DATE: 5/6/2013 T:(65o) 636 -1028 F:(650) 638 -1029 (888) -SCI. -CITY (765 -2489) www.solarcity.com PAYMENT TYPE: PPA INVE IER: (1r POWER -ONE # AURORA PVI- 4.2 -OUTD 3 6' to PL 25' to PL I Total roof area is 2048 sq ft. Total array area is 396 sq ft. 5% coverage. 1.1 Front Of House N a O --U O 10620 Madrid Rd Gas Main 1 C:r-'1C:n1n (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC EEEI DC DISCONNECT & WARNING LABELS AC EEI AC DISCONNECT & WARNING LABELS JUNCTION BOX M DC COMBINER BOX & WARNING DISTRIBUTION PANEL & WARNING Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER CONDUIT RUN ON EXTERIOR - -- CONDUIT RUN ON INTERIOR GATE /FENCE --- INTERIOR EQUIPMENT SITE PLAN w Scale: 3/32" = 1' Z 01, 10' 21' 3 CONFIDENTIAL -THE INFORMATION HEREIN JOB NUMBER J B -9 5 017 3 8 0 0 PREMISE OWNER: AHJ: Cupertino DESCRIPTION: DESIGN: -�6#% CONTAINED SHALL NOT BE USED FOR THE PITCH: 17 PITCH: 17 ZHAO, XIAODONG ZHAO RESIDENCE MWALK ,SolarCity. MARKET: REST MODULES: 22 TRINA SOLAR TSM- 245PC05 PADS. MP1 AZIMUTH: 269 ARRAYA AZIMUTH: 269 Alp, , PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH C U P E R TI N O, CA 95014 r/ && -� MATERIAL: Comp Shingle STORY: One PROJECT MANAGER: MOUNTING SYSTEM: 3055 Clearview Way Son Mateo, CA THE SALE AND USE OF THE RESPECTIVE PITCH: 17 ARRAY PITCH: 17 —L SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PAGE NAME: 4O8 306 -1132 S —US SITE PLAN SHEET: REV: DATE: PV 2 5/6/2013 MP2 AZIMUTH: 179 ARRAY AZIMUTH: 179 INVE TER: (1� POWER —ONE #AURORA PVI- 4.2 —OUTD 1,r! a. MATERIAL: Comp Shingle STORY: One F r & M yy °16. °fYas4 4 i F y CUPERTINO , Building Department D 30'toPL PV4 I MAY 16 2013 REVIEWED FOR CODE COMPLIANCE . : 87toPL Reviewed By —5 ^- 3 6' to PL 25' to PL I Total roof area is 2048 sq ft. Total array area is 396 sq ft. 5% coverage. 1.1 Front Of House N a O --U O 10620 Madrid Rd Gas Main 1 C:r-'1C:n1n (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC EEEI DC DISCONNECT & WARNING LABELS AC EEI AC DISCONNECT & WARNING LABELS JUNCTION BOX M DC COMBINER BOX & WARNING DISTRIBUTION PANEL & WARNING Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER CONDUIT RUN ON EXTERIOR - -- CONDUIT RUN ON INTERIOR GATE /FENCE --- INTERIOR EQUIPMENT SITE PLAN w Scale: 3/32" = 1' Z 01, 10' 21' 3 CONFIDENTIAL -THE INFORMATION HEREIN JOB NUMBER J B -9 5 017 3 8 0 0 PREMISE OWNER: AHJ: Cupertino DESCRIPTION: DESIGN: -�6#% CONTAINED SHALL NOT BE USED FOR THE ZHAO, XIAODONG ZHAO RESIDENCE MWALK ,SolarCity. MARKET: REST MODULES: 22 TRINA SOLAR TSM- 245PC05 PADS. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN $ 10620 MADRID RD 5.39 KW PV Array Alp, , PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH C U P E R TI N O, CA 95014 r/ && -� PROJECT MANAGER: MOUNTING SYSTEM: 3055 Clearview Way Son Mateo, CA THE SALE AND USE OF THE RESPECTIVE Comp Mount Type C —L SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PAGE NAME: 4O8 306 -1132 S —US SITE PLAN SHEET: REV: DATE: PV 2 5/6/2013 T'(650) 638 -1028 F:(650) 638 -1029 (88s) -Sa -CITY (765 -2486) www.solarcit.com PAYMENT TYPE: PPA INVE TER: (1� POWER —ONE #AURORA PVI- 4.2 —OUTD RAFTER: 2x10 SUPPORT: 2x10, 2x12, 3 1/2 x 16 PSL MAX SPAN: 17' -8" A SIDE VIEW OF MP1 PV MODULE 5/16" BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA LAG BOLT WITH SEALING WASHER (2 -1/2" EMBED, MIN) (E) RAFTER SUBSEQUENT MODULES S (E) 2x10 RAFTER ® 16" O.C. (E) 3 1/2 x 16 PSL RIDGE BOARD (E) 2x12 CEILING JOIST ® 12" O.C. I INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT HOLE. (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. (3) 1NSER7 FLASHING. (4) PLACE MOUNT. (5) INSTALL LAG BOLT WITH SEALING WASHER. G(6) INSTALL LEVELING FOOT WITH BOLT & WASHERS. (E) 200 RAFTERS 16" SPACING FRONT VIEW OF MPI SCALE: 1/2" = 1 CUPERTINO Building Department MAY 'I S" 2013 REVIEWED FOR DOGE CONI L IAILCE Reviewed By CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART IZ OTHERS EPT IDE THE RECIPIENTS VAT ORGANIZAl10N, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: J B- 9 5 017 3 8 00 MISE OWNER AH r Cupertino DESCRIPTION: ZHAO, XIAODONG ZHAO RESIDENCE 810620 MADRID RD 5.39 KW PV Array C U P E R TI N O, C A 9 5014 PAGE NAME S —US (408) 306 -1132 STRUCTURAL VIEWS M WALK �`„!' 1 �� �« SoiaiCity. MARKET: REST MODULES 22 TRINA SOLAR TSM- 245PCO5 PADS. PROJECT MANAGER: MOUNTING SYSTEM: Comp Mount Type C 3055 Clearview Way San Mateo, CA T: (650) 638 -109�F (650) 636 -7029 (B86) -65O) 638 (765 -2489) www.e�arasty.aam SHEET. REV: DAIS PV 3 5/6/2013 r��ENT TYPE PPA IN IiJE 11 POWER —ONE # AURORA PVT- 4.2 —OUTD RAFTER: 2x10 SUPPORT: 2x10, 2x8 MAX SPAN: 16' -8" � SIDE VIEW OF MP2 PV MODULE 5/16" BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA LAG BOLT WITH SEALING WASHER (2 -1/2" EMBED, MIN) (E) RAFTER SZ STANDOFF (E) 2x10 RAFTER ® 16" O.C. (E) 2x8 CEILING JOIST @ 16" O.C. (E) 200 RAFTERS ® 16" SPACING FRONT VIEW OF MP2 SCALE: 1/2" = 1' CUPERTINO Building Department MAY 16 203 REVIEWED FOR CODE COMPLIANCE Reviewed By J� CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT IN VMOLE INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART IZ OTHERS OUTSIDE THE CONNECTION VAS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. INSTALLATION ORDER PREMISE OWNER: AHJ: Cupertino DESCRIPIION: ZHAO XIAODONG ZHAO RESIDENCE 8 1 0620 MADRID RD 5.39 KW PV Array CUPERTINO, CA 95014 PAGE NAME: S —US (408) 306 -1132 STRUCTURAL VIEWS. DESIGN: MWALK (1) LOCATE RAFTER, MARK HOLE LOCATION, AND DRILL PILOT HOLE. MODULES 22 TRINA SOLAR TSM- 245PC05 PA05. &Awl M&LI. C ) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. MOUNTING SYSTEM: Comp Mount Type C 3055 Clearview Way San Mateo, CA E(850) 638 -109�F (650) 638 -1029 1 (BBB) -SOL -CITY (765 -2489) www.solarcity.com (3) INSERT FLASHING. IN TER: IN( POWER —ONE # AURORA PVI- 4.2 —OUTD (4) PLACE MOUNT. (5) INSTALL LAG BOLT WITH SEALING WASHER. (6) IN LEVELING FOOT WITH BOLT & WASHERS. (E) 200 RAFTERS ® 16" SPACING FRONT VIEW OF MP2 SCALE: 1/2" = 1' CUPERTINO Building Department MAY 16 203 REVIEWED FOR CODE COMPLIANCE Reviewed By J� CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT IN VMOLE INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART IZ OTHERS OUTSIDE THE CONNECTION VAS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: J B- 9501738 00 PREMISE OWNER: AHJ: Cupertino DESCRIPIION: ZHAO XIAODONG ZHAO RESIDENCE 8 1 0620 MADRID RD 5.39 KW PV Array CUPERTINO, CA 95014 PAGE NAME: S —US (408) 306 -1132 STRUCTURAL VIEWS. DESIGN: MWALK ��I�' ��� ! '= s ''/,,sO�a��t y. MARKET: REST MODULES 22 TRINA SOLAR TSM- 245PC05 PA05. &Awl M&LI. PROJECT MANAGER: MOUNTING SYSTEM: Comp Mount Type C 3055 Clearview Way San Mateo, CA E(850) 638 -109�F (650) 638 -1029 1 (BBB) -SOL -CITY (765 -2489) www.solarcity.com SHEET REV: DATE: PV 4 5/6/2013 PAYMENT TYPE: PPA IN TER: IN( POWER —ONE # AURORA PVI- 4.2 —OUTD UPLIFT CALCULATIONS SolarCity 05.06.2 Wind Uplift Calculator Version # PV System Type Comp Roof # er-4 (Comp Roof Only) 0 SotarClty SleekMount'TM' Comp Roof 1 ASCE 7 -05 Roof Slope indscape 170 U Rafter Spacirid M. ally/Fully Enclosed Method 167 '.O.C. 13 sf PV Module Orientation V Landscape 85 mph Total Area of Array Fig. 6-1 387 sf b PV Module Width C 3.3 ft Section 6.5:6.3 - PV Module Length 0 5.4 ft Gable Roof Attachment TVDe Fig. 6- 11s /C/D -14gre Coma Mount Tvve C h 1 Wind Design Code 0 48" ASCE 7 -05 ?`�'��!/ � .I,, SolarQV. indscape Wind Design Method U 24" M. ally/Fully Enclosed Method TribCL 13 sf Basic Wind Speed V IN TER: (1 POWER —ONE #AURORA PVT- 4.2 —OUTD 85 mph 3 psf Fig. 6-1 Exposure.CategorY b PCL C 39 Ibs Section 6.5:6.3 - Roof We 0 - 1521.bs, Gable Roof - 426lbs Fig. 6- 11s /C/D -14gre Me;Rof Helg►t h 637lbs b ft section 6 Least Horiz Dim of Building, LHD 66.04 Oft Wan ,Area,(, M64M A 17:6 sf i$e.i5if9:71 Roof Wind Zone Width a 3 ft Wind Directionality Factor Kd 0.85 Section 6-4 Velocity Pressure qh, qh = 0.00256 (Kz) (Kzt) (Kd) (VA2) (1) Equatlon 6-15 ia,2n f Max Allowed Foot X- Spacing Max Allowed X Cantilever Max Standoff Tributary Area PV Assembly Dead Load DLPV WLUP'= 0.6 DLPVcos(6) Attachment Uplift Capacity TCL/Tallow indscape 4W 48" 48" ?`�'��!/ � .I,, SolarQV. indscape 24v 24" 24" PROECT MANAGER: TribCL 13 sf 13 sf 13 sf IN TER: (1 POWER —ONE #AURORA PVT- 4.2 —OUTD WPV 3 psf 3 psf 3 psf PCL 39 Ibs 39 Ibs 39 Ibs TCL - 1521.bs, - 2741bs - 426lbs Tallow 637 Ibs 637lbs 637Ibs )CRLand 21x. 43:0% 66.04 CUPERTINO f Building Department ,oil MAY I "� 2013 REVIEWED FOR CODE COM P iANCE Reviewed By, hr 111/ CONFIDENTIAL — 'ME INFORMATION HEREIN CONTAINED SHALL NOT E USED FOR THE BENEFlT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT 8E DISCLOSED IN WHOLE OR IN PART IZ OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCnY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION of SOLARGTY INC. JOB NUMBER J B- 9501738 00'" °Y"� ""& Cupertino DESCRIPTION: ZHAO, XIAODONG ZHAO RESIDENCE $10620 MADRID RD 5.39 KW PV Array CUPERTINO, CA 95014 408 306 -1132 PAGE NAME S —US ( UPLIFT CALCULATIONS DEIGN: MWALK ?`�'��!/ � .I,, SolarQV. MARKET: REST MODULES: 22 TRINA SOLAR TSM- 245PCO5 PADS. PROECT MANAGER: MOUNTING SYSTEM: Comp Mount Type C 3055 Clearview Way Son Mateo, CA T: (650) 638- 1028F:(650) 638 -1029 (e6srsa -aTY (765 -24as) www.solarcRy.cam SHEET: REV DATE:- 5 6 2013 PV 5 / / PAYMENT TYPE: PPA IN TER: (1 POWER —ONE #AURORA PVT- 4.2 —OUTD BOND (N) #8 GEC TO (N) GROUND ROD E 200A MAIN SERVICE PANEL Inv 1: UU Ungrounded INV 1 — ( 1 ) POWER —ONE # AURORA PM -4.2— OUTD —S —US LABEL- A — (22) TRINA SOLAR # TSM- 245PC05/PA05.18 (;A # 6661 U4 Inverter 24OV, 96% PV Module; 245W, 222.9W PTC, 4OMM, Block Frame C -46, C -10 AT PANEL WITH IRREVERSIBLE CRIMP E 200/2P MAIN CIRCUIT BREAKER Voc: 37.3 Panel Number: NA INV 2 Vpmax:30.7 Meter Number: 1005904728 *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN Underground Service Entrance INV 3 THE DC STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. MAIN SERVICE PANEL I I — (1 )MURRAY # MP22520 PV BACKFEED BREAKER Breaker, 20A iP -25A 2P- 20A /1P, 2 Spaces, Quad — (1) Ground Rod /8' x , Copper AC ( 1) AWG #10, THWN -2. Black O (1) AWG #10, THWN -2, Red ( 1 )AWG #10, THWN -2, White NEUTRAL Vmp =240 VAC Imp =20 AAC ....... - ( 1) AWG #B..1HWN -2., Green, . EPC /GEC (1, ) Conduit, Kit;. 3/47 EMT ......... Inverter 1 IND POWER —ONE RORA PVT -4.2— OUTD —S —US -- - - - - -- 1 I - DO NOT ADJUST MIN. ACTIVATION V LTAGE I — DC +— DC- — — —1 String(s) Of 11 On MP 2- ----------- EGC - - -� GC-- 1------------- - - - - -- — (1 ) Conduit Kit; 3/4' EMT DO NOT ADJUST MIN. AMVATION V LTAGE 1 String(s) Of 11 On MP 1 --- --- ---- ---� CUPERTINO Building Depatnent MAY 196 2013 REVIEWED FOR CODE COMPLIANCE Reviewed By, Val O zaov Voc 410.3 VDC Isc = 8.47 ADC EGC Vmp = 337.7 VDC Imp= 7.98 ADC O(1) GFP /GFCI ❑N ........................... . Voc = 410.3 VDC Isc = 8.47 ADC EGC Vmp = 337.7 VDC Imp= 7.98 ADC — — BENEFIT OF ANYONE EXCEPT SOLARCITY INC., E NOR SHALL IT BE DISCLOSED IN WHOLE OR IN -- - - - - -- 1 I - DO NOT ADJUST MIN. ACTIVATION V LTAGE I — DC +— DC- — — —1 String(s) Of 11 On MP 2- ----------- EGC - - -� GC-- 1------------- - - - - -- — (1 ) Conduit Kit; 3/4' EMT DO NOT ADJUST MIN. AMVATION V LTAGE 1 String(s) Of 11 On MP 1 --- --- ---- ---� CUPERTINO Building Depatnent MAY 196 2013 REVIEWED FOR CODE COMPLIANCE Reviewed By, Val O (2 ) AWG 110, PV WARE, Black i ( 1 ) AWG #B. Said Bare Copper Voc 410.3 VDC Isc = 8.47 ADC EGC Vmp = 337.7 VDC Imp= 7.98 ADC O(1) ( 1) Conduit Kit:.3 /4', EMT .......... ( 2) AWG f10. PV WARE, Block AWG #B, Solid Bare Copper ( ?)Conduit Kii . 3/4' , EMT ...................................... ........................... . Voc = 410.3 VDC Isc = 8.47 ADC EGC Vmp = 337.7 VDC Imp= 7.98 ADC CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT USED FOR THE JOB NUMBER J B- 9501738 OO PREMISE OWNER aHt Cupertino DESCRIPTION: ZHAO, XIAODONG ZHAO RESIDENCE DESIGN: a,'•!' II'„�SolarCity. MARKET: REST MODULES: 22 TRINA SOLAR TSM- 245PCO5 PA05. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., E NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 810620 MADRID RD 5.39 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH CUPERTINO, CA 95014 PROECT MANAGER: MOUNTING SYSTEM: 3055 Clearview Way San Mateo, CA THE SALE AND USE OF THE RESPECTIVE COnT Mount Type C PAGE NAME: SHEET: REV: DATE: PAYMENT TYPE: PPA IN TER (1 POWER —ONE # AURORA PVT- 4.2 —OUTD SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. S —US (408) 306 -1132 THREE LINE DIAGRAM PV 6 5/6/2013 T: (650) 636 - 1024402 50) 638 -1029 1 (868) -SCI -CITY (765 -2489) www.solarcitycom 1. Conductor Sizing per Art 690.8(6) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current. b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(B)(16). c. Evaluate conductor temperature at terminations per 110.14(C). Ampacity of wire derated for conditions of termination must . be >= continuous current *1.25. All string terminations are rated at 90' C. 2. OCP Sizing per Art 690.8(B)(1) a. Round up to next size per Art 240.4(B) ------------------------------------------- 3. Conductor Sizing per Art 690.8(A) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current. b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(8)(16). c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current *1.25. All branch terminations are rated at 75' C min. ------------------------------------------ 4. OCP Sizing a. Round up to next size per Art 240.4(B) 5. Conductor Sizing per Art 690.8(A) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current. b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(B)(16). c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current *1.25. All inverter output terminations are rated at 75' C. 6. OCP Sizing a. Round up to next size per Art 240.4(B) 7. Conductor Sizing per Art 690.8(A) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current. b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(6)(16). c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current *1.25. All inverter output terminations are rated at 75' C min. Module: Inverter 1: Module: Inverter 2: Module: Inverter 3: Module: Inverter 4: ELECTRICAL CALCULATIONS 22 TRINA SOLAR # TSM- 245PC05 1222.9 1 Inv Power I WPTC Voltage Drop Calculations Version 5_8.0 1 Power -One PVI -4.2 -5 10.96 14800 14707. 65 Vdrop = i lm 2 * Length' * Resistance I m ) Total: 22 Modules Photovoltaic Module Electrical Specifications: Voc: 37.3 V Vmp: 30.7 V Isc: 8.47 A Imp: 7.98 A Tvoc: - 0.11532 V /deg C Tisc: 4.185 mA/deg C String Type A and 2 Combined Strings Type A Power -One PVI -4.2 -S 11 TRINA SOLAR # TSM 245PC05 Voc= 410.3 Vmp= 337.7 Isc= 8.47 Imp= 7.98 Total Inv Pwr: 4800 4707.65 PTC Total STC: 5390 dea F dea C Record Low Temp Max Average Hi Temp Record Hi Temp: Icont= 10.59 Art 690.8(A)(1 1.a Conductor: AWG 10 PV Wire 32 0 82 28 89 32 Voc Correction Method: Manuf Tvoc data Voc Correction Factor: 40 1.b Inverter Min Vdc Input: 120 3.c Icont = (Amps) Start ampacity Temperature derate ( % =F) Conduit fill derate ( %_ #) Derated ampacity Min Vmp at Max Temp: 307.6 d284 Max Voc at Min Temp: 442.01 Icont * 1.25 = (Amps) Ampacity Inverter Max Vdc Input: 600 Icont * 1.25 = (Amps) OCP Size = Max String Size: 14 Inverter Type 1 -way wire length: 80 Hi:82 Power -One PVI -4.2 -S 1 way wire length: 10 ft Icont = 201A Art 690:8(A)(1) Icont * 1.25 = (Amps) 30 deg C ampacity = 13.23 40 1.b Icont= (Amps) Start ampacity Temperature derate ( % =F) Conduit fill derate ( %_ #) Derated ampacity 10.59 3.c Icont = (Amps) Start ampacity Temperature derate ( % =F) Conduit fill derate ( %_ #) Derated ampacity 20 d284 1.c Icont * 1.25 = (Amps) Ampacity 13.23 40 1.d Icont * 1.25 = (Amps) OCP Size = 13.23 15 Inverter Type A Output 1 AWG_10 j at Max Ave Power -One PVI -4.2 -S 1 way wire length: 10 ft Icont = 201A Art 690:8(A)(1) 3.a Icont * 1.25 = (Amps) OCP Size = 25 Art 690.8(B)(1) Art 240.6(A) 25 3.b Conductor: AWG -10 Icont * 1.25 = (Amps) 30 deg C ampacity = THWN -2 at 90 deg C: Table 310.16 25 40 3.c Icont = (Amps) Start ampacity Temperature derate ( % =F) Conduit fill derate ( %_ #) Derated ampacity 20 AWG -10 40 0.91 1 36.4 3.d Icont * 1.25 = (Amps) Ampacity 25 307.604 35 Total voltage drop in AC conductors = 0.08 Total voltage drop in AC and DC conductors = 0.59 Branch Circuit Type A Im A Max. Length ft Wire p 410.3 String: 7.98 80 AWG -10 at Max Ave Hi:82 Vdrop = 7. 1 40hms / 307.604 0.51 Branch: FT9-8--T 0 1 AWG_10 j at Max Ave Hi:82 Vdrop = ( 7.98 1 40hms) / 307.604 0 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PAGE NAME: S -US (408) 306 -1132 ELECTRICAL CALCULATIONS Total volta a droD in DC conductors = 0.51 Inverter: 1 7.98 1 10 1 AWG_10 at 240V Vdrop = ( 7.98 2U 0.0012 Ohms ) / 240 V 0.0798 Combinedi 0 0 1 j at 240V Vdrop = 0 U Ohms) / 240 V 0 Total voltage drop in AC conductors = 0.08 Total voltage drop in AC and DC conductors = 0.59 Branch Circuit Type A 75degC 1 strings per branch 1 11 modules per series string Voc-- 410.3 V Vmp= 337.7 V Isc= 8.47 IAWG A Imp= 7.98 A Icont= 10.59 A 2.a Conductor 1: _10 Conductor 2: 1 AWG 10 Icont * 1.25 = (Amps) 30 deg C ampacity = 2.b Icont= (Amps) Start ampacity Temperature derate ( %-- Conduit fill derate Derated ampacity 2.c Temp table Icont *1.25= (Amps) Ampacity 2.d OCP Size = 1 way wire length: 1 strings per branch 2 11 Im odules per series string Voc-- 410.3 V Vmp= 337.7 V Isc= 8.47 A Imp= 7.98 A Icont= 10.59 A Art 69 PV Wire 75degC PV Wire 13.23 Conductor 1 Conductor 2 13.23 13.23 40 40 10.59 10.59 40 40 0.82 0.82 0.81 0.8 26.24 26.24 Term 1 Term 9 75degC 75degC 13.23 13.23 35 35 15 T 15 Combined Inverter Output Service Voltage= Total Inverter Power- 1 wa Icont = # of inverters *max inverter current Art 6 Icont = Am s deg F deg F 0 MAC 1 PERTINQ ng .Department 2013 4.a Icont *1.25 = (Amps) Art 69ft. f(I WED FOR C DE COMPLIANCE OCP size = Art 240.6(A) 4.b Conductor: THVVN 2 at 90 deg C: TabR@0fb1ked By �y,.r 17AT� Icont * 1.25 = (Amps) 30 deg C ampacity = 4.c Icont = (Amps) Start ampacity Temperature derate ( % =F) Conduit fill derate ( % = #) Derated ampacity 4.d Icont * 1.25 = (Amps) CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER J B -9 5 017 3 8 0 0 PREMISE OWNER MI Cupertino DESCRIPTION: ZHAO, XIAODONG ZHAO RESIDENCE DESIGN: MWALK MARKET; REST MODULES- 22 TRINA SOLAR TSM- 245PCO5 PAO5. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 810620 MADRID RD 5.39 KW PV Array •'I'�SolarCity. o PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH C U P E R TI N 0, CA 95014 r/II� PROJECT MANAGER MOUNTING SYSTEM: 3055 gearview Way Son Mateo, CA THE SALE AND USE OF THE RESPECTIVE Comp Mount Type C _L SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PAGE NAME: S -US (408) 306 -1132 ELECTRICAL CALCULATIONS SHEET- REV: DATE: PV 7 5/6/2013 T:(650) 638 -102�F (650) 638 -1029 1 (888) -SOL -CITY (765 -2489) www.solarcitycom PAYMENT TYPE: PPA IN TER: 1) POWER -ONE # AURORA PVI- 4.2 -0UTD Label Location: (C) Per Code: CA Fire Guidelines Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (DC) (INV) Per Code: CEC 690.5(C) Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 Label Location: (AC) (POI) Label Location: (AC) (POI) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.13.4 Label Location: (POI) Per Code: CEC 690.64.13.4 Label Location: (DC) (INV) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED CUPER`fINO Building Department i MAY 1 6 2013 REVIEWED FOR CODE COMPLIANCE Reviewed By (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �► San Mateo, CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC - CA Label Set �;•...• T:(650)638 -1028 F:(650)638 -1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE /l SolarCitv-1 ( 888)- SOL- Cm(765 -2489) www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. mono multi solutions - - - --- - - Trinamount II nvr.:nsdar FOR PITCHED ROOF 10 YEAR PRODUCT WARRANTY FOR MODULE AND MOUNTING SYSTEM 5X FASTER TO INSTALL ULTRA LOW RESISTANCE SUITABLE FOR COMBINING PV MODULE EXPERTISE WITH A HIGHLY / INNOVATIVE MOUNTING SYSTEM SOLUTION. ® COMPOSITION SHINGLE Trina Solar is introducing Trinamount - the fastest, easiest and least Maximum Power Voltage -VMP (V) expensive way to mount PV modules onto residential and commercial 29.8 rooftops. With a series of drop -in and quarter -turn connections on a TRAPEZOIDAL METAL ® specialized module frame, this mounting solution installs up to 5 times Maximum Power Current -IMPP (A) faster than conventional mounting systems. Trinamount connects STANDING SEAM ROOF ® directly to the module frame, eliminating the need for long rails. By drastically reducing the number of parts, cost of materials and 7.89 installation time, Trinamount offers the optimal solution for residential Open Circuit Voltage -Voc (V) and commercial installations. Trinamount II FOR PITCHED ROOF TSM -PC05 / PA05.18 mono multi solutions ELECTRICAL DATA @ STC TSM -225 TSM -230 TSM -235 TSM -240 TSM -245 DIMENSIONS OF PV MODULE TSM -PC05 / PA05.18 PC /PA05.18 PC /PA05.18 PC /PA05.18 PC /PA05.18 PC /PA05.18 Peak Power Watts -PM x (Wp) 225 230 235 240 245 938 P O 1 0 +3 0 +3 0 +3 + +3 Al jA I 1�1 Back View ower u puf Tolerance -Pnwx ( %) / / / 0/ 3 0/ Maximum Power Voltage -VMP (V) 29.4 I 1�1 Back View ower u puf Tolerance -Pnwx ( %) / / / 0/ 3 0/ Maximum Power Voltage -VMP (V) 29.4 29.8 30.1 30.4 30.7 Maximum Power Current -IMPP (A) 7.66 7.72 7.81 7.89 7.98 Open Circuit Voltage -Voc (V) 36.9 37.0 37.1 37.2 37.3 Short Circuit Current -Isc (A) 8.20 8.26 8.31 8.37 8.47 Module Efficiency gm ( %) 13.7 14.1 14.4 14.7 15.0 I -V CURVES OF PV MODULE TSM- 230PC05 / PA05.18 900 --- -- 1000 ' 890 _. ------ ..-------------- .--------------- ------- -__ -- 700 - --------- -- -- -- - -- -- - -- - -- I BDOW /m2-- -- - - - - -- 690 _ __.__ ------------- a 600w/m2 400- idovw %mT "------ ------------- - - - - -- -- - - - - - - -- U 3. r--------- -- --- --- --- -- - - ------ zaow /m 2P° -- - - - -- - -- 100 -- - D°° - -- -- -- - -- ------------ - - - - -- -- 000 1000 20"0 3040 404° Voltage (VI Values al Standard Test Conditions STC (Air Mass AM 1.5, Irradiance 1000W /m', Cell Temperature 25 °C). ELECTRICAL DATA @ NOCT TSM -225 TSM -230 TSM -235 TSM -240 TSM -245 PC /PA05.18 PC /PA05.18 PC /PA05.18 PC /PA05.18 PC /PA05.18 Maximum Power (W) 164 168 172 175 178 Maximum Power Voltage (V) 26.9 27.1 27.4 27.7 27.8 Maximum Power Current (A) 6.12 6.20 6.27 6.32 6.41 Open Circuit Voltage (V) 33.8 33.9 34.0 34.1 34.2 Short Circuit Current (A) 6.62 6.68 6.70 6.75 6.83 NOCT: Irradiance at 800W /m'. Ambient Temperature 20°C. Wind Speed I M /s. MECHANICAL DATA Solar cells Cell orientation Module dimension Weight Glass Frame J -Box Cables / Connector TEMPERATURE RATINGS Nominal Operating Cell Temperature (NOCT) Temperature Coefficient of P- Temperature Coefficient of Voc Temperature Coefficient of Isc Multicrystalline 156 x 156mm (6 inches) 60 cells (6 x 10) 1650 x 992 x 40mm (64.95 x 39.05 x 1.57 inches) 20.3kg (44.81b) High transparancy solar glass 3.2mm (0.13 inchesl Anodized aluminium alloy IP 65 rated Photovoltaic Technology cable 4.0mm2 (0.006 inches'), I I00mm (43.3 inches), MC4 / H4 46 °C ( ±2 °C) 0.43 % / °C 0.32 % / °C 0.047 % / °C MAXIMUM RATINGS Operational Temperature - 40 - +85 °C Maximum System Voltage 1000V DC(IEC)/ 600V DC(UL) R Max Series Fuse Rating 15A CERTIFICATION E ®1 PV`iLE �i t I Uus WARRANTY 10 year workmanship warranty cC \I I)v� a 25 year linear performance warranty (Please refer to product worronty for details) ti ooMPATjA( • Trinasolar A W Trinasolar The power behind the panel eapPAt`e The power behind the panel UPERTINO RUilding D "ipartment :t MAY 2013 i I � EWED FOR CODE COMH IANCE Reviewed By I� I �r sz g I^ CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. 0 2011 Trina Solar Limited. All rights reserved. Specifications included in this datasheet are subject to change without notice. SolarCity SleekMountT"" - Comp The SolarCity SleekMount hardware solution is optimized to achieve superior strength and aesthetics while minimizing roof disruption and labor. The elimination of visible rail ends and mounting clamps, combined with the addition of array trim and a lower profile all contribute to a more visually appealing system. SleekMount utilizes Zep CompatibleTM modules with strengthened frames that attach directly to Zep Solar standoffs, effectively eliminating the need for rail and reducing the number of standoffs required. In addition, composition shingles are not required to be cut for this system, allowing for minimal roof disturbance. • Utilizes Zep Solar hardware and UL 1703 listed Zep CompatibleTM modules • Interlock and grounding devices in system UL listed to UL 2703 • Interlock and Ground Zep ETL listed to UL 1703 as "Grounding and Bonding System" • Ground Zep UL and ETL listed to UL 467 as grounding device • Painted galvanized waterproof flashing • Anodized components for corrosion resistance • Applicable for vent spanning functions Components 5/16" Machine Screw 0 Leveling Foot I* Lag Screw Comp Mount 0 Comp Mount Flashing T,a l"SolarCity. ® January 2013 SolarCity SleekMounff - Comp w_ OOMPATjB qi?���3" LISTED - � ?pSolarCity a� 00 ® January 2013 �MPP Installation Instructions Drill Pilot Hole of Proper Diameter for Fastener Size Per NDS Section 1.1.3.2 Seal pilot hole with roofing sealant Insert Comp Mount flashing under upper layer of shingle Place Comp Mount centered upon flashing Install lag pursuant to NDS Section 11.1.3 with sealing washer. Secure Leveling Foot to the Comp Mount using machine Screw Place module CUPERTINO Building Depatrent MAY 1 2013 REVIEWED FOR CODE COMPLIANCE Reviewed By /N sower -ogre= `JRenewob/e Energy Solutions NwIll 0 Of U rd IaG�etiIR4110 AURORA Nominal Output Power _ _ _ _ _ ._ _ W 3000 _. __. 3600 _. __... -- - -- 4200 ...__ _._ _._.. Maximum Output Power W 3000 ! 3300** 3300 ** 3600 4000 ** 4000* 4200 4600 ** 4600 "* Rated Grid AC Voltage V 208 240 277 208 240 277 208 240 277 Input Side(DC7. ._.:. _ .. _... _.._ _. _ - - _ Number of Independent MPPT Channels 2 2 2 Maximum Usable Power for Each Channel W 2000 3000 3000 Absolute Maximum Voltage (Vmax) V 600 600 600 Start-Up Voltage (Vstart) V 200 (adj. 120-350) 200 (adj. 120-350) 200 (adj. 120-350) Full Power MPPTVoltageRange V _ 160 -530 120 -530 140 -530 Operating MPPT Voltage Range V _. _. 0.7xVstart-580 _ _ 0.7xVstart-580 0.7xVstart -580 Maximum Current (ldcmax) for both MPPT in Parallel A 20 32 32 Maximum Usable Current per Channel A 10 16 16 Maximum Short Circuit Current Limit per Channel A 12.5 20 20 mr of Wire Landing Terminals Per Channel Nu be 2 Pairs 0 on -S version) 2 Pairs (1 on -S version) 2 Pairs (1 on- S version) Array Wiring Termination Terminal block Pressure Clamp, AWG10 AWG4 Output Side (AC) Grid Connection Type 10/2W Split- 10/2W 10/2W Split- 10/2W 10/2W Split- 10/2W '._0/3W.. AdlustableVoltagep3 nge(Vmin -Vmax) . V Rata._. - ...,._.0/3W 183 -228 211 -264 244 -304 183 -228 211 -264 244304 183 -228 211 -264 244304 Grid Frequency Hz 60 60 60 _.- Adjustable Grid Frequency Range Hz 57 60.5 57-60'S 57 60.5 _ -._ Maximum Current (lacmax) _ Arras 145 145 12 17.2 16 16 20 j 20 20 Power Factor > 0.995 > 0.995 > 0.995 Distortion Total Harmonic Distortion At Rated Power ; 0/0 ; < 2 <2 ' < 2 _._. Rate. _. _ ... . Grid Wiring TermknationType- _ ._ ._ . _. _ . _ . - - -- -- - -- - - - -- - - - - -- - -- - -- - - - -_- -- - -- _ .Rata. _ Terminalblock ,PressureClamp,AWG10 -ter Protection Devices ,, -- Input -_ Reverse Polarity Protection Yes Yes Yes Over - Voltage Protection Type, .- _ Varistor, 2 for each channel Varlstor, 2 for each channel Varistor, 2 for each channel PV Array Ground Fault Detection Pre startup Riso and dynamic GFDI (Requires Floating Arrays) Output ----------------- _ - Anti - Islanding Protection Meets UL 1741%IEE7547 Meets UL 1741AEE1547 Meets UL 1741%IEE1547 - _._._ requirements- _--- __- _.__... - - -._- „_requirements_ -- - _ - - _requirements,_ Over Votage Protection Type Varstor, 2 (L, - Lz % L, - G) Varistor _2 (_L, Lz L, G) Va__ristor, 2 (L, - L, % L, G) Maximum AC OCPD Retina A . 20 20 15 25 20 20 25 25 25 % 96.9 97 97 % 96 96 96 Wens <06 <0.6 <0.6 t� �Cs°�"'” f.�v��::�.�ti��„4,t o ����i�,a.��"�M .::),� '. �r �� p�•�r�s���^�S�d�.�x�mri� ��rr�"����� .s,..Sars...0 , 16 characters x 2 lines LCD display ... _ ................ AURORA UNIVERSAL( opt.) --- -- -- _-= --- -- _-_---------- ' - -- ------------------------ I --- PVI- US &R5485 232 Ambient AirOperating Temperature Range 'p ('C) -13 to +140 ( -25 to +60) with -13 to ±140 ( -25 to+60) with i -13 to +140 ( -25 to +60) with --------------------------------------- --------------------- ------- ---- deratingabovet3l,( 55),--- :------ deratingabove113 OS) _Ambient Air Storage Temperature Range °F (°C) t -40 to 176 (-40 to +80) -40 to 176 (-40 to +80) i, ._, -40 to 176 (-40 to ±80) , Relative Humidity %RH 01.00 condensing _, r __ 0100tondensing ........... - __0100 condensing. _ Acoustic Noise Emission Level „db jA) @1 m _ <50 < 50 < 50 Maximum 0 ratan Altitude without Deratin ft(m) 6560 (2000) 6560 (2000) 6560 (2000) Endosureratin�_ _ _ __ __ i NEMA 4X NEMA 4X NEMA4X _. Cooking _ NaturalConvection Natural Convection NaturalConvechon Dlmensions (H x W x D) - - Weight Ib /(kg) <47.3 (21.3) -S version <47 3 (21.3) S version <47 3 (21 3) -5 version. Mounting System Wall bracket Wail bracket Wall bracket -_- _ .._ _ .__ .._ _.._. _.. Rata_ _ - - -- - - - - -_ . - Trade size KOs: (tea x 1 /21 and Trade size KOs: (tea x 1/2') and Trade size KOs: (tea x 1/21 and Conduit Connections * - Rea x 1 -1/4; 3 places side, front (2ea x 1 -1/4, 3 places sid2-0. IX,, 3 places side, fro [g � y / q rear) rear) rear) UPEF2` INO DC Switch Rating (Per Contact) AN B/600 25/600 25/600 f Building Department Isolation Level Transformerless (Floating Array) Transformerless (Floatm prmerless (Floating Array) and EMC Standard UL 1741 CSA - C22.2 N. 107.1 -01 UL 1741 CSA C22.2 N.6f1, CSA - C22.2 N 107."1 Safety Approval CSA, CSA, .`1A 1.' 2013 Warranty '' , Standard Warranty years 10 10 10 _._. Extendedwarra�ty ._. - years is &zo __. is &zo f�REVIEWED 1PK CODE COIV1Pi_IpiVCE AvaUabk Models Standard- Without DC Switch and Wiring Box PVI -3.0- OUTD -US PVI- 3.6-0UTD -US PVI -4.2- OUTD -US With DC Switch and Wiring Box PVI -3.0 OUTD -S-US PVI- 3.6- OUTD -S -US rye VgeN1Cs" s 'Ali data Is subject to change without notice "Capability enabled at nominal AC voltage and with suficlent DC power available -- When equipped with optional DC Switch and Wiring Box F • OSA INTERNATIONAL Certificate of Compliance Certificate: 2096477 Master Contract: 173688 Project: 2439385 Date Issued: July 19, 2011 Issued to: Power -One, Inc 740 Calle Plano Camarillo, CA 93012 USA Attention: Robert White The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. ® RQIr}(eMPSt&Ck' Issued by: Rob Hempstock, AScT. C us PRODUCTS CLASS 531109 - POWER SUPPLIES - Distributed Generation Power Systems Equipment CLASS 531189 - POWER SUPPLIES Distributed Generation - Power Systems Equipment - Certified to U.S. Standards Utility Interactive Inverter, Models PVI- 4.2- OUTD -US, PVI- 3.6- OUTD -US, PVI- 3.0- OUTD -US, PVI -4.2- OUTD-S-US, PVI -3.6- OUTD -S -US, PVI -3.0- OUTD -S -US, PVI -4.2- OUTD -US -W, PVI -3.6- OUTD -US -W and PVI- 3.0- OUTD -US -W; provided with two DC input channels, permanently connected. For details related to ratings, reference should be made to the CSA Certification Record, Appendix 1 or the Descriptive Report. APPLICABLE REQUIREMENTS CSA -C22.2 No. 107.1 -01 - General Use Power Supplies UL Std No. 1741- Second Edition - Inverters, Converters, Controllers and Interconnection System Equipment for Use With Distributed Energy Resources (January 28, 2010) DQD 507 Rev. 2009-09 -01 Page: 1 In CUPERTINO 2 Building Department SAY I A 2 REVIEWED FOR CC)I)E COMPLANCE Reviewed By _ jam,,, /74"r / ^ 'SolarCity To Whom It May Concern, VVe would like to reinstate Pennit#:13OSO137 for 1O62O Madrid Rd, Cupertino, Ca. BSO14.The installation of the PV system is complete and just requires a final inspection. Gerry Igtanloc SolarCity ° CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10620 MADRID RD CONTRACTOR: SOLARCITY PERMIT NO: 13050127 OWNER'S NAME: XIAODONG ZHAO 3055 CLEARVIEW WAY DATE ISSUED: 05/16/2013 OWNER'S PHONE: 4083061132 SAN MATEO, CA 94402 PHONE NO: (650) 638 -1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL INSTALL 22 ROOF TOP FLUSH MOUNTED SOLAR PANELS License Class C tO C 4 (0 Lic. # '6 ��' 1 5.37 KW Contractor 56L /b C 1 T ` , Date Z 1 _ REV # 1 - CHANGE MODULE FROM TRINA TO I hereby affirm that I am licensed under the provisions of Chapter 9 ADVANTAGE - ISSUED 1/2/2014 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is.in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $22000 erformance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 35608042.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above, information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DA C LED INSPECTION. indemnify and keep harmless the City of Cupertino. against liabilities, judgment costs, and expenses which may accrue against said City in consequence of the Date: granting of this permit. Additionally, the applicant understands and will comply 4s,s y: with all non -point source regulations per the Cupertino Municipal Code, Section RE- ROOFS: 9.18. Signature Date Z Al roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER- BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury. one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(x) should I store or handle hazardous I have and will maintain a Certificate of Consent to self - insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sectio 5 5, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this Owner or authorized agent: Date: permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making thiscertificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date ti A AC BLDG CONC C DC EGC (E) EMT G GALV GEC GND HDG I Imp INVS Isc kVA kW LBW MIN MIR (N) NEC NIC NTS PC PL PV PVC S SCH SS SSD STC SWH TYP UON UPS V Vmp Voc W 3R ABBREVIATIONS AMPERE ALTERNATING CURRENT BUILDING CONCRETE COMBINER BOX DISTRIBUTION PANEL DIRECT CURRENT EQUIPMENT GROUNDING CONDUCTOR EXISTING ELECTRICAL METALLIC TUBING SOLAR GUARD METER GALVANIZED GROUNDING ELECTRODE CONDUCTOR GROUND HOT DIPPED GALVANIZED CURRENT CURRENT AT MAX POWER INVERTERS SHORT CIRCUIT CURRENT KILOVOLT AMPERE KILOWATT LOAD BEARING WALL MINIMUM MIRROR NEW NATIONAL ELECTRIC CODE NOT IN CONTRACT NOT TO SCALE ON CENTER PANEL BOARD PROPERTY LINES PHOTOVOLTAIC POLYVINYL CHLORIDE SUBPANEL SCHEDULE STAINLESS STEEL SEE STRUCTURAL DRAWINGS STANDARD TESTING CONDITIONS SOLAR WATER HEATER TYPICAL UNLESS OTHERWISE NOTED UNINTERRUPTIBLE POWER SUPPLY VOLT VOLTAGE AT MAX POWER VOLTAGE AT OPEN CIRCUIT WATT NEMA 3R, RAINTIGHT ELECTRICAL NOTES 1. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 2. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 3. A NATIONALLY — RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 25O.92(B) 5. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 7. MODULE FRAMES SHALL BE GROUNDED AT THE UL— LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, RAIL, BOXES, ETC.) SHALL BE GROUNDED USING UL LISTED LAY —IN LUGS LISTED FOR THE PURPOSE. POSTS SHALL BE MADE ELECTRICALLY CONTINUOUS WITH ATTACHED RAIL. 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS AND GROUNDED AT THE MAIN ELECTRIC PANEL. 10. THE DC GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED ACCORDING TO ART. 250.166(8) & 690.47. INDEX PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 STRUCTURAL VIEWS PV5 UPLIFT CALCULATIONS PV6 THREE LINE DIAGRAM Cutsheets Attached GENERAL NOTES 1. THIS SYSTEM IS GRID — INTERTIED VIA A UL— LISTED POWER— CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS INVERTER INPUT CIRCUIT ARE UNGROUNDED. 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED 5. ALL WORK TO BE DONE TO 2010 CALIFORNIA BUILDING CODE. 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2008 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2010 CALIFORNIA ELECTRIC CODE. CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: J B -95 PREMISE OWNER: AHJ: Cupertino CONTAINED SHALL NOT BE USED FOR THE ZHAO, XIAODONG MARKET- MODULES: BENEFIT OF ANYONE EXCEPT SOLARCITY INC., 10620 MADRID RD NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST 22 Advanta a Module PART TO OTHERS OUTSIDE THE RECIPIENTS CUPERTINO CA 95014 PROJECT MANAGER: ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE Comp Moun T e C SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. S (408) 306 -1132 PAYMENT TYPE: PPA INVERTER: POWER —ONE # AURORA PVI- 4.2— OUTD —S— LICENSE CA # 888104 C -46, C -10 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DMSI - APPROVED This set of plans and specifications MUST be kept at the job site during construction. t is unlawful to make an changes or alterations on same, or to deviate therefrom, without approval from the Building Official. The Stamping of this plan and specifications SHALT. NOT be held to permit or to be an approval of the violation cf any ' rdinance or State Lave. �.„;, I son 11'FFICk COPY VICINITY MAP DESCRIPTION: 0 I E 5.5 W PV Array PAGE NAME: COVER SHEET JURISDICTION NOTES FLASHING WILL BE PAINTED TO MATCH EXTERIOR Installing 22 —roof top flush— mounted panels (5.39kW) APN: 356 -08 -042 r 1 i IVFD i JAN 2 2014 CUPERTINO 11(.tr Building Department 2013 REVIEVVED FOR CODE COMPLIANCE Reviewed By hh71,11 REV BY DATE COMMENTS REV A TBLAU 12/31/2011 CHGD MODULES TO ADVANTAGE 250 i* • e DESIGN: Michael Walker SHEET: REV: DATE: PV 1 a 12/31/201 3055 Clearview Way San Mateo, CA 94402 T:(650) 638 -1028 F:(650) 638 -1029 (888) —SOL —CITY (765 -2489) www.solorcity.com BOND (N) #8 GEC TO (E) GROUND ROD E 200A MAIN SERVICE PANEL AT PANEL WITH IRREVERSIBLE CRIMP �E� 20012P MAIN CIRCUIT BREAKER Panel Number. Meter Number: 1005904728 INV i INV 2 INV 3 I) POWER—ONE III AURORA 00W, PVI- 4.2— OUTD —S —US LABEL A Inverter. Ziabee 4224OV. 96% (1)MBrookeer,#20AFP 25A/2P- 20A /1P, 2 Spaces, Quadd BREAKER AC Inverter I IND POWER —ONE RORA PVI- 4.2— OUTD —S —US Advantage Module PV Module; 250W, 227.9W PTC, Poly, 60cell, Bick Frame, White Bcksht, ZEP Voc: 38.4 Vpmax:30.1 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER SolarCity # 88E C -10 ADJUST MIN. ACTIVATION VO TAGE 1 String(s) Of 11 On MP 2 -- — — — — — — — — - - - -� (I )Conduit Kit; 3/4° EMT MIN. ACTIVATION VO TAGE ig(s) Of 11 On MP 1 --------- - - - - -i CUPERTINO Building Department 2 r:`VIC FOR CaDE COMPLIANCE Reviewed By J 9,a •�j/AT (1) 21xa2rOS1R GS, UNFUSEDNGROUNDED DC — (2 ) ZEP !! 850- 1196 -001 Combiner Box Bracket; For ZEP, bottom mount only (1 AWG 110, THWN -2, Black (1 AWG #10, THWN -2, Black Voc* = 469.79VDC Isc =8.87 ADC (2 )AWG #10, PV WIRE, Black Voc* = 469.79VDC Isc =8.87 ADC O Isl— (1 ) AWG #10, THWN -2, Red O (1)AWG #10, THWN -2, Red Vmp = 331.1 VDC Imp= 8.31 ADC O (1)AWG #10, Solid Bare Copper EGC Vmp = 331.1 VDC Imp= 8.31 ADC LO=LL � (I)AWG #10, THWN -2, White NEUTRAL Vmp =240 VAC Imp AAC (1 AWG #10, THWN- 2,,Green . EGC (1 AWG #10, THWN —Y, Block Voc* = 469.79VDC Isc = 8.87 ADC (2 AWG 00, PV WIRE, Black Voc * _ L.] 469.79VDC Isc = 8.87 ADC ® (1) AWG 110, THWN -2, Red Vmp = 331.1 VDC Imp = 8.31 ADC 2 (1) AWG #10, Solid Bare Copper EGC Vmp = 331.1 VDC Imp= 8.31 ADC (1) AWG /10 THWN -2, .Green.. EGC ..... .. LLLL^JJJJ CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE 7aV PREMISE OWNER: AHJ: Cupertno DESCRIPTION: ZHAO, XIAODONG ZHAO RESIDENCE DESIGN: Michael Walker GFP /GFCI a MARKET: MODULES: BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Advantage Module PV Module; 250W, 227.9W PTC, Poly, 60cell, Bick Frame, White Bcksht, ZEP Voc: 38.4 Vpmax:30.1 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER SolarCity # 88E C -10 ADJUST MIN. ACTIVATION VO TAGE 1 String(s) Of 11 On MP 2 -- — — — — — — — — - - - -� (I )Conduit Kit; 3/4° EMT MIN. ACTIVATION VO TAGE ig(s) Of 11 On MP 1 --------- - - - - -i CUPERTINO Building Department 2 r:`VIC FOR CaDE COMPLIANCE Reviewed By J 9,a •�j/AT (1) 21xa2rOS1R GS, UNFUSEDNGROUNDED DC — (2 ) ZEP !! 850- 1196 -001 Combiner Box Bracket; For ZEP, bottom mount only (1 AWG 110, THWN -2, Black (1 AWG #10, THWN -2, Black Voc* = 469.79VDC Isc =8.87 ADC (2 )AWG #10, PV WIRE, Black Voc* = 469.79VDC Isc =8.87 ADC O Isl— (1 ) AWG #10, THWN -2, Red O (1)AWG #10, THWN -2, Red Vmp = 331.1 VDC Imp= 8.31 ADC O (1)AWG #10, Solid Bare Copper EGC Vmp = 331.1 VDC Imp= 8.31 ADC LO=LL � (I)AWG #10, THWN -2, White NEUTRAL Vmp =240 VAC Imp AAC (1 AWG #10, THWN- 2,,Green . EGC (1 AWG #10, THWN —Y, Block Voc* = 469.79VDC Isc = 8.87 ADC (2 AWG 00, PV WIRE, Black Voc * _ L.] 469.79VDC Isc = 8.87 ADC ® (1) AWG 110, THWN -2, Red Vmp = 331.1 VDC Imp = 8.31 ADC 2 (1) AWG #10, Solid Bare Copper EGC Vmp = 331.1 VDC Imp= 8.31 ADC (1) AWG /10 THWN -2, .Green.. EGC ..... .. LLLL^JJJJ CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: J B- 9501738 00 PREMISE OWNER: AHJ: Cupertno DESCRIPTION: ZHAO, XIAODONG ZHAO RESIDENCE DESIGN: Michael Walker `��toIi .1191111 o";., MARKET: MODULES: BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 10620 MADRID RD 5.5 KW PV Array 'I' SolarCity. REST 22 Advantage Module PART OTHERS OUTSIDE THE RECIPIENTS ORGANIZIZ ATION, EXCEPT IN CONNECTION WITH CUPERTINO, CA 95014 PROJECT MANAGER: MOUNTING SYSTEM: 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN OF SOLARCITY Comp Mount Type C PAGE NAME: PACE (408) 306 -1132 San Mateo, CA 94402 T:(650) 638 -1028 F :(650) 638 -1029 SHEET: REV: DATE PV 6 PAYMENT TYPE INVERTER: IS PERMISSION INC. PPA POWER —ONE #AURORA PVI- 4.2— OUTD —S— S THREE LINE DIAGRAM a (888) —SOL —CITY (765 -2489) www.Warcitycom mmi SolarCity Advantage Module The SolarCity Advantage module represents a 60 Cell, ZEP enabled module. The values shown are the most extreme potential values from SolarCity's portfolio of CEC approved and UL or ETL listed modules. Modules will have a minimum 10 year warranty. The module installed will be one of the following: Yingli Solar: YL2XXP -29b Trina Solar: PA05.18 ReneSola: JC2XXM -24Bb BenQ: PM245P01 2XXW Canadian Solar: CSPX -2XXPX Electrical Parameters at Standard Test Conditions (STC) Power Output Pmax W 245 250 Power Output Tolerances APmax W -0/ +5 -0/ +5 Module Efficiency nm % 15.23 15.54 Maximum Power Voltage Vmp V 30.2 30.1 Maximum Power Current Impp A 8.17 8.31 Open- circuit voltage Voc V 37.8 38.4 Short- circuit current Isc A 8.63 8.87 Values at Standard Test Conditions STC (Air Mass AM1.5, Irradiance 1000W /m', Cell Temperature 25 °C). Electrical Parameters at Nominal Operating Cell Temperature (NOCT) Nominal operating cell temperature Power Output Pmax W 178 185 Voltage at Pmax Vmpp V 27.8 27 Current at Pmax Impp A 6.54 6.7 Open- circuit voltage Voc V 34.5 3-1 Short- circuit current Isc A 7.08 7.25 NOCT: Irradiance at 800W /m2 , Ambient Temperature 20 °C, Wind Speed 1M /s. Thermal Characteristics Nominal operating cell temperature NOCT °C 46+/-2 Temperature coefficient of Pmax y % / °C -0.45 Temperature coefficient of Voc PVoc % / °C -0.34 Temperature coefficient of Isc alsc % / °C 0.065 General Characteristics Solar Cells Multicrystaline Frame Aluminum alloy/ anodized black Weight 45.2 Ibs (20.5 kg) i _............_�; CUPERTINO Building Department fi "R, GODE COMPLIANCE YGE Z 60 YL245P -29b � YL245P -296 CELL SERIES YL245P -29b YL235P -29b YL230P -29b • Ideal for residential and commercial applications where cost savings, installation time, and aesthetics matter most. ► Lower balance -of- system costs with Zep Compatible`" frame. ► Reduce on -roof labor costs by more than 25 %. ► Leverage the built -in grounding system - if it's mounted, it's grounded. ► Lower your parts count - eliminate rails, screws, mounting clips, and grounding hardware. ► Design and permit projects easily with access to layout calculator and stamped drawings. ► Lower installation costs with savings across equipment and labor. ► Minimize roof penetrations while maintaining the system's structural integrity. 1 Invest in an attractive solar array that includes a black frame, low mounting profile, and aesthetic array skirt. ► Increase energy output with flexible module layouts (portrait or landscape). ► Trust in the reliability and theft - resistance of the Zep Compatible" system. AC SOLUTION OPTION The YGE -Z Series is now available as an Enphase Energized- AC Solution. This solution delivers optimum performance and integrated intelligence. The Enphase M215 -Z Zep Compatible Microinverter is designed to connect directly into the Z Series module groove, eliminating the need for tools or fasteners - all with one easy step. Intelligent real -time _. monitoring at the system and module level with Enlighten. YIN OLAR AWN U.S. Soccer Powered by Yingli Solar Leading limited power warranty* ensures 91.2% of rated power for 10 years, and 80.7% of rated power for 25 years. 10 -year limited product warranty. * In compliance with our warranty terms and conditions. UL 1703 and ULC 1703, CEC, FSEC, ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007, SA8000 C �L us ! CERT- rpHO.oL «STEUoovu_I 44DD YINGLISOLAR.COM /US I Yingli Americas YGE-Z 60CELL SERIES ELECTRICAL PERFORMANCE Test Conditions (STC) Electrical parameters at Module type �' Standard B • Y1_250P -296 YL245P -296 1I YL245P -296 YL235P-296 YL230P -29b Power output W 250 245 i 240 235 230 Module efficiency -- n nm + % i' 15.3 _ 11- 15.0 j: _ _ -14.7 14.4 14.1 Voltage at P. V,,:pv'i V 30.4 lil 30.2 I 29.5 I, 29.5 29.5 Current at Pm.. I A 8.24 8.11 4 8.14 _ ICI 7.97 7.80 Open - circuit voltage VI, V I 38.4 'j 37.8 37.5 37 0 37.0 Short- circuit current 11 1 A 8.79 8.63 jl 8.65 8.54 jll 8.40 STC: 1000W/m2 irradiance, 25 °C cell temperature, AM1.5g spectrum according to EN 60904 -3 Average relative efficiency reduction of 5.0% at 200W /m2 according to EN :50904.1 Operating Electrical parameters at Nominal 46+/-2 Temperature coefficient of P:,.,. I y ij w-C ii Power output �'' P:�,,. , W 181.1 177.9 174.3 Voltage at Pm.. ji, V�PY V I^ 27.6 27.2 26.6 170.7 (j 167.0 26.6 Current at P. I'.h_PP i A E 6.56 j 6.54 I 6.56 X26.6 �1 6.42 j� 6.29 Open - circuit voltage li V_ V 35A 1s 34.5 34.2 ~� 33.8 3~ 3.8 Short-circuit current I:< !! A P,: 7.12 6.99 :i 7.01 11 6.92 6.81 NOCT: open- circuit module operation temperature at 800W/m2 imadiance, 20 "C ambient temperature, 1 m/s wind speed THERMAL CHARACTERISTICS Nominal operating cell temperature ii Nocr °C 46+/-2 Temperature coefficient of P:,.,. I y ij w-C ii -0.45 Temperature coefficient of V« II 0- > %rc C -0.33 Temperature coefficient of IK li ax %/ °C) 0.06 Temperature coefficient of VmPp 6vmw @ -0.45 OPERATING CONDITIONS Max. system voltage 600V. Max. series fuse rating 15A Limiting reverse current 15A Operating temperature range -40 to 194°F( -40 to 90 °C) Max. static load, front (e.g., snow, and wind) 50 psf (2400 Pa) Max. static load, back (e.g., wind) 50 psf 12400 Pa) Hailstone impact 1 in (25 mm) at 51 mph (23 m /s) CONSTRUCTION MATERIALS Front cover (material/typetthickness) - Low -iron glass / tempered / 3.2 mm Glass may have anti - reflective coating Cell ( quantity/materiaVtype /dimensions/ area /# of busbars) 60 / polysilicon / mukicrystalline / 156 mm x 156 mm / 243.3 ant / 2 or 3 Encapsulant (material) Ethylene vinyl acetate (EVA) Frame (material/color) Anodized aluminum alloy/ black Junction box (protection degree) zIP65 Cable (type /length /gauge /outside diameter) PV Wire / 43.31 in (1100 mm) / 12 AWG / 0.244 in (6.2 mm) Plug connector (manufacturer /type /protection degree) I Amphenol / H4 / IP68 The specifications in this datasheet are not guaranteed and are subject to change without prior notice. This datasheet complies with EN 50380:2003 requirements. Yingli Green Energy Americas, Inc. info@yingliamericas.com Tel: +1 (888) 686 -8820 YINGLISOLAR.COM /US I NYSENGE ®Yngli Green Energy Holding Co. Ltd. I YGEZ60Cel1Series2012 _EN_201206_V01 Powered by YINGLI GENERAL CHARACTERISTICS Dimensions(UW /H) 64.96 in (1650 mm)/38.98 in (990 mm)/ 1.81 in (46 mm) Weight 45.2 lbs (20.5 kg) PACKAGING SPECIFICATIONS Number of modules per pallet:. 22 Number of pallets per 53' container ! 36 Packaging box dimensions (L/W /H)', 67 in (1700 mm) / 45 in (1150 mm) / 47 in (1190 mm) Box weight C 1076lbs (488 kg) Units: inch (mm) CUPERTINO Building Department SE(MON G-C r 1 FOR CODE COMPLIANCE Iry Warning: Read the InstallatioFi J� i �" entirety 7 y / + before handling, installing, and opera'�ingiK�t rthYr�lles. c-/�nd Our Partners YIN OLAR ., U.S. Soccer Powered by Yingli Solar GreenTriplex PM245PO I Multi- Crystalline Photovoltaic Module gym-•° • o n'.rr+w:''. e- ,`_nom-- '•••����..._. s, 9, �R ms's Power Range 245 - 260 Wp oPV OMPAtj OMPPT CYCLE V O BenQ BenQ Solar GreenTriplex PM245P01 (245 - 260Wp) Electrical Data Typ. Nominal Power PN Highly Strengthened Design 25OW Module complies with advanced loading tests to ��.., meet 2400 Pa loading requirements 15.2% PI-67 Rated Junction Box j Advanced water and dust proof level Typ. NominalVoltageVmp (V) Integrated Racking Solution N Simplifies installation process and reduces labor costs oPV OMPAtj OMPPT CYCLE V O BenQ BenQ Solar GreenTriplex PM245P01 (245 - 260Wp) Electrical Data Typ. Nominal Power PN 245W 25OW 255W 260W Typ. Module Efficiency 15.2% 15.5% 15.8% 16.1% Typ. NominalVoltageVmp (V) 30.3 30.6 30.8 31.2 Typ. Nominal Current I,np (A) 8.09 8.17 8.28 8.34 Typ. Open CircuitVoltageVoc M 37.2 37.4 37.6 37.7 Typ. Short Circuit Current Isc (A) 8.64 8.69 8.76 8.83 Maximum Tolerance of PN OperatingTemperature - 40- - +85'C 0/+3% -40 - +45 °C • Above data are the eHeco a measurement at Standard Test Conditions (STC) I 000 Senal Fuse Rating 15A, • STC: irradiance 1000 W /W, specual di,uibudon AM 1.5, temperature 25 ±2'C, In accord -o wsh EN 60904 -3 Tested up to 2400 Pa according to UL 1703 -The even electnol dam are nom nal values which account for basic measurements and manufacturing tolerances of t I0%, Wth the exception of Pu The class fat ons is performed according to P,i Certifications According to UL 1703 guidelines v Please confirm other cert tat ons with official Temperature Coefficient Packing configuration Container 20' GP 40' GP 40' HQ NOCT 46 ± 2 °C Typ.Temperature Coefficient of PN -0.44 % / K Typ.Temperature Coefficient ofVoc -0.32 %/ K Temperature Coefficient of Isc 0.04 % / K •NOCT:N -tad Opendon Celli penture,measudngconduonsmadimce BWW/ m', AMI. Sa ,rtempeature20°C.windspeed l m/s Mechanical Characteristics Dimensions (L xW x H) 1639 x 983 x 40 mm (64.53 x 38.70 x 1.57 in) Weight 19.Skg (43 Ibs) Front Glass High transparent solar glass (tempered), 3.2 mm (0.13 in) Cell 60 muldcrysalline solar cells, 156 x 156 mm (6" x 6 ") Cell Encapsulation EVA Back Sheet Composite film (White) Frame Anodized aluminum frame (Black) Junction Box IP -67 rated with 3 bypass diodes Cables 1 x 4 mm' (0.04 x 0.16 inch?), length: each 1.0 m (39.37 in) Connector Type Tyco PV4 Operating Conditions OperatingTemperature - 40- - +85'C AmbientTemperature Range -40 - +45 °C Max System Voltage UL I 000 Senal Fuse Rating 15A, Maximum Surface Load Capacity Tested up to 2400 Pa according to UL 1703 Warranties and Certifications Product Warranty Maximum 10 years for material and workmanship Performance Guarantee Guaranteed output of 90% for 10 years and 80% for 25; yea rs Certifications According to UL 1703 guidelines v Please confirm other cert tat ons with official dealers Packing configuration Container 20' GP 40' GP 40' HQ Pieces per pallet 26 26 26 Pallets per container 6 14 28 Pieces per container 156 364 728 AU Optronics Corporation No. I, Li -Hsin Rd. 2, Hsinchu Science Park, Hsinchu 30078,Taiwan Tel: +886 -3- 500-8899 E -mail: BenQSolar@auocom www.BenQSolarcom Dimensions mm [inch] FromViev Back Vie [s IUghtview 1.571 IN Curve 9.0 8.0 J.0 Q 6.0 S.a 4.0 3.0 2.0 1.0 00 Holm x4 IN curve vs d'df. irradiance ......................... Atns [045] 40 Ds�] .3 ............................. ........ [I ........ 2 A-A Cross Section a i I I 300 ' in - -- 1 -f0 m - 200�dma - 0 s 10 IS 20 25 30 35 40 . Voltage M Cumant'voltage chamoteristics.with dependence on irradiance and module temperature. Dealer Stamp BenQ Solar is a division of AUOptronics Thise- heetispdnted.thSyink © Copyright May 2013 AU Operonics Corp. All rights reserved. Information may dtange wirhout notice. CUPIE TINO Building Depat nent i( �e V EV',"JEi r Ok C ;ODE CU W P L I A N C E i <evjewed By �E11r r : yfiiG WwBenQ Solar Mono Multi Solutions TSM - PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE DIMENSIONS OF PV MODULE TSM - PA05.18 TSM=PA05.18 THE TRINAMOUNT MODULE E 60 CELL MULTICRYSTALLINE MODULE WITH TRINAMOUNT FRAME 240 -260W POWER OUTPUT RANGE 15.97 As a leading global manufacturer of next generation photovoltaic products; we believe close cooperation with our partners is critical to success. With local presence around the globe, Trina is able to provide exceptional service to each customer in each market and supplement our innovative, reliable products with the backing of Trina as a strong, bankable partner. We are committed to building strategic, mutually beneficial collaboration with installers, developers, distributors and other partners as the backbone of our shared success in driving Smart Energy Together. Trina Solar Limited www,trinasolar.com Trinasolar Smart Energy Together I � Our most versitile product ;1 • Compatible with all major BOS components and system designs One of the industry's most trusted modules .;�. • Over 2 GW sold across all major global markets • Field proven performance 941 mm 604.3GFOUrvprvG rvOlE A A iz -oaniry NaE 812mm 180 Back View nL I,V CURVES OF PV MODULE TSM -245 PA05.18 a Highly reliable due to stringent quality control I, • Over 30 in -house tests (UV, TC, HE and many more) • In -house testing goes well beyong certification requirements Certified to withstand challenging environmental ®conditions • 130 km /hr wind load (2400 Pa) • 900 kg snow load per module (5400 Pa) LINEAR PERFORMANCE WARRANTY 0.40 10.0' 20.- 30.°' 40.0' Voltage(V) CERTIFICATION° mr�x 1 a E C &US PVCYCLE LISTED �r Trinasolar Smart Energy Together MECHANICAL DATA TSM -240 TSM -245 TSM -250 TSM -255 TSM -260 ELECTRICAL DATA @STC PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 Peak Power Watts -PMAX (WP) 240 245 250 255 260 Power Output Tolerance -I'mm ( %) 0/ +3 0/ +3 0/ +3 0/ +3 0/ +3 Maximum Power Voltage -VMP (V) 29.7 30.2 : 30.3 : 30.5 30.7 Maximum Power Current -IMPP (A) 8.10 8.13 837 8.36 8.47 Open Circuit Voltage -Voc (V) 37.3 37.5 37.6 37.7 37.9 Short Circuit Current -Isc (A) 8.62 8.68 8.85 8.92 9.00 Module Efficiency qm ( %) 14.7 15.0 15.3 15.6 15.9 STC: Irradiance 1000 W /m', Cell Temperature 250C, Air Mass AM1.5 according to EN 60904 -3. Average efficiency reduction of 4.5% at 200 W 1m2 according to EN 60904 -1. MECHANICAL DATA TSM -240 TSM -245 TSM -250 TSM -255 TSM -260 ELECTRICAL DATA @ NOCT PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 Maximum Power -PMnz (Wp) 174 178 181 184 188 Maximum Power Voltage -VMP (V) 26.6 26.8 27.0 2Z2 27.4 Maximum Power Current -IMPP (A) 6.55 6.64 6.70 6.77 6.86 Open Circuit Voltage (V) -Voc IV) 34.1 34.2 34.3 34.4 34.6 Short Circuit Current (A) -Isc (A) 7.04 : 7.10 Z25 7.31 7.37 NOCT: Irradiance at 800 W /m', Ambient Temperature 200C, Wind Speed I m /s. MECHANICAL DATA Solar cells :. Multicrystalline 156. 156 mm (6 inches) Cell orientation 60 cells (6 x 10) Module dimensions 1650 x 992 x 40 mm (64.95 x 39.05 x 1.57 inches) Weight 18.6 kg (41.0 lbs) Glass High tra nsparency solar glass 3.2 m m (0.13 inches) Backsheet White Frame Black Anodized Aluminium Alloy with Trinamount Groove J -Box I IP 65 or 1P 67 rated Cables Photovoltaic Technology cable 4.0 mm' (0.006 inches'), j 1100 mm (43.3 inches) Connector j Original MC4 TEMPERATURE RATINGS Nominal Operating Cell 45 °C ( ±2 °C) Temperature (NOCT) Voltage' . Max Series Fuse Rating Temper,atureCoefflc left t,ofPruk 3 % / 1C Temperature Coefficient of Voc - 0.32 % / °C Tem perature Coefficient of Isc 1 0.047%/ °C' WARRANTY 10 year Product Workmanship 1 25 year Linear Power Warranty (Please refer to product warranty for MAXIMUM RATINGS Operational Temperature, - 40 - +85 °C Maximum Sye4`im, i 11000V DC((EC)/ i OC(t)L) Voltage' . Max Series Fuse Rating 600V , 15A UPEP { 110 Building Depa ent PACKAGING CONFIGURATION U FOR CODE C011IPt- Modules per box: 24pieces iRe Vl ewe i7 By 5Es3n` Modules per 40' container: 672 pieces m rt 0 ref CAUTION: READ SAFEMAND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. GA*PA;, ©2013 Trina Solar Limited. All rights reserved. Specifications included in this datasheet are subject to change without notice. i ) ;oviro r ReneS-Wla 1".Sll q1i High Module Conversion Efficiencies ° 0 IBM x'150?: �qD �ee 0 C N (L coU co E 0 EL Zep Compatible Mechanical Load Capability of up to 5400 Pa Conforms with IEC 61215:2005, IEC 61730: 2004, UL 1703 PV Standards 1509001, OHSAS18001, IS014001 Certified Application Class A, Safety Class 11, Fire Rating C 0 1 5 10 15 20 25 YEAR Black also available APPROVED PRODUCT n QGOMrATgm c ©us C (A) �� Ewa - EN w PV CYCLE 0 LISTM rocs J 4 latertek v `,.R 7materialwo 2 ��• linear power output ReneSolaxom Rene S-a Virtus@ii Module "Ill, 245W, 250W, 255W, 2607 Dimensions IN Curves Voltage M Irradlance 200W/m7 40OW /mt 6WW /mt 800W/m, 1000W /m' Drawing Only for Reference uxnwaeox ��x a 16.1% 16.0% Maximum Power (Pmax) 24S W 250W 255 W 260 W wager ecah-mxr oaAmxou vur xou 3 Voltage M Irradlance 200W/m7 40OW /mt 6WW /mt 800W/m, 1000W /m' Packing Information Drawing Only for Reference Efficiency 15.8% 16.2% 16.2% 16.1% 16.0% Maximum Power (Pmax) 24S W 250W 255 W 260 W Power Tolerance 0 -KW - 0 - .SW 0- SW 0 --SW Module Efficiency 15.1% 15.4% 15.7% 16.0% Maximum Power Current (imp) 8.19A 9.31A 8.39A 853A Maximum Power Voltage (Vmp) 29.9 V 30.1 V 30.4 V 30.5 V Short Circuit Current (in) 8.73A 8.83A 2.86A 8.95A Open Circuit Voltage (Voc) 375 V 37.4 V 37.5 V 37.6 V Values at Standard Test Conditions STC (Air Mass AM7.5, Irradiance 10DOW /mr, Cell Temperature 25 °C) , Electrical Characteristics Maximum Power (Pmax) a 192 w r 185 W law 193 W Maximum Power Current (imp) 653A 657A 6.63A 6.74A Maximum Power Voltage (Vmp) 275 V 282 V 28.5V 28.6 V Short Circuit Current(Isc) 7.04A 7.12A 7.20A 727A Open Circuit Voltage (Voc) 35.0 V 355 V 35.5 V 352 V Values at Normal Operating Cell Temperature, Irradiance of goo W /mr, spectrum AM 1.5, ambient temperature 2M wind speed 1 We Mechanical Characteristics Cell Type 2566456 mm PolyaystaW„e, 6016x10) pa M series Temperature CoeflklentoFVoc 450%/°C Glass High Transmission, taw IrMTemPoe "Glass Temperature Coefficient of fix: 0.04%/,0 Frame An dlaed MannMum Alloy Temperature Cdef clentofPmax -0A0%f C Junction Box IP65/IP67 rated, with bypasdioda Nominal Operating Cell Temperature(NOCT) 45°CtrC Dimension •64A x 391 x 25 Inches Output Cable 12 AW6, 39A/472 Inches Weight 44.1 lbs Installation Hale location SftD,.wingAb- Packing Information / UPERTIX10 Container 20'GP 40•GP 40'X0 Operating Temperature it1 �k S�F 3uildinq Department Pallets per Container 12 28 28 Maximum System Voltage (EU) /600VDC (US) Pieces per Container 300 700 770 r,,,}000VDC Maximum Series Fuse Rating I� w.; 20A 5EU) /j20A (US) ne1rRDLwaoS Onrt •Ow:bb,nbswferroiemsem¢MOilm ) `4 UMOx:al xrxb rberveE.O,bp„nO �MUxen,rtxgenw AaiRwNw[plttrotlre. - ..�.�. ..�... _...... ... "NI EVIEv'vi =i.. i'UR reviewed By ReneSola.com DE WIVIPLIANCE J�11 ,iA11111 i QQe I I I III �l Key Features • Quick and easy to Install - dramatically reduces installation time • Lower system costs - can cut rooftop Installation costs in half • Aesthetic seamless appearance - low profile with auto leveling and alignment • Built -in. hyper- bonded grounding system - if it's mounted, it's grounded • Theft resistant hardware • Ultra-Iowpp'rts count - 3 parts for the mounting and grounding systern • industry first comprehensive warranty insurance by AM $estratedie4ding insurance conipani,"In the world • Industry leading pins only power tolerance: 0 - +SW • Backward compatibility with all standard rooftop and ground mounting systems • Backed By Our New 10125 Linear Power Warranty Plus our added 25 year insurance coverage 1$70 t Added Value CS6P•240P asx F . rom Warranty Nominal Maximum Power Pmax Y 240W 246W fir#. t §'� 255W Optimum Operating Voltage Vmp 29.8V 29.9V 5 16 1s 20 25 ' $1 CanadianSolar Next Generation Solar Module NewEdge, the next generation module designed for multiple types of mounting systems, offers customers the added value of minimal system costs, aesthetic seamless appearance, auto groundingand theft resistance. The black- framed CS6P -PX is a robust 60 cell solar module incorporating the groundbreaking Zap compatible frame. The specially designed frame allows for rail -free fast installation with the industry's most reliable grounding system. The module uses high efficiency poly - crystalline silicon cells laminated with a white back sheet and framed with black anodized aluminum. The black- framed CS6P -PX is the perfect choice for customers who are looking for a high quality aesthetic module with lowest system Cost. Best Quality • 235 quality control points in module production • EL screening to eliminate product defects • Current binning to improve system performance • Accredited Salt mist resistant Best Warranty Insurance • 25 years worldwide coverage • 100 %d warranty term coverage • Providing third party bankruptcy rights • Non - cancellable • Immediate coverage • Insured by 3 world top insurance companies Comprehensive Certificates • IEC 61216, IEC 61730, IEC61701 ED2, UL1703, CEC Listed, CE and MCS • IS09001: 2008: Quality Management System • ISO/TS16949:2009: The automotive quality management system • IS014001:2004: Standards for Environmental management system • QC080000 HSPM: The Certification for Hazardous Substances Regulations • OHSAS 18001:2007 International standards for occupational health and safety • REACH Compliance • 10 year product warranty on materials and workmanship • o A 6S' ♦ p � a ' /EF 25 year linear power output warranty www.canadiansolar.com Electrical Data CS6P- 235/240/245/2501255PX Black- framed STC C86P•235P CS6P•240P CS6P -245P CS6P- 280PXCS6P -255PX Nominal Maximum Power Pmax 236W 240W 246W 25OW 255W Optimum Operating Voltage Vmp 29.8V 29.9V 30.OV 30.1V 30.2V Optimum Operating Current (Imp) 7.90A 8.03A 8A7A 8.30A 8.43A Open Circuit Voltage (Voc) 36.9V 37.OV 37.1V 37.2V 37AV Short Circuit Current (Ise) 8.46A 8.59A 8.74A 8.87A 9.00A Module Efficiency 14.61% 14.92% 15.23% 1 15.54% 15.85% Operating Temperature - 40'C - +85'C Maximum System Voltage 1000V IEC /600V UL Maximum Series Fuse Rating 15A Application Classification Class A Power Toterance 0 - +5w Under Standard Test Conditions (STC) of Inmdlance Of 1 dad WIM', Spectrum AM Ld and cell temperature or 20 v NOCT CS6P -235P CS6P -240P CS6P -245P CS6P•250PXCS6P -255PX Nominal Maximum Power Pmax 170W 174W 178W 181W 185W Optimum Operating Voltage (Vmp) 27.2V 27.3V 27AV 27.5V 27.5V optimum Operating Current (imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage (Voc) 33.9V 34.OV 34.1V 34.2V 34AV Short Circuit Current (Isc) 6.86A 6.96A 7.08A 7.19A 7.29A Under Normal Operating Cell Temperature, Irradlance of 900 W /m', spectrum AM 1.5, ambient temperature 201C, wind speed We Mechanical Data Cell Type Poly - crystalline 156 x 156mm, 2 or 3 Busbars CsllArrangement 60 (6 x 10) Dimensions 1638 x 982 x 40mm (64.5 x 38.7 x 1.57in) Weight 20.5kg (45.2lbs) Front Cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy J -BOX IP65,3diodes Cable 4mm'(IEC) /12AWG(UL),1000mm Connectors MC4 or MC4 Comparable Standard Packaging (Modules per Pallet) 24pcs Module Places per container (40 ft. Container) 672pcs (40'HO) 1 -V Curves (CS6P- e 7 6 - � 5 a 3 — :o00wJa+2 Z — 8now(m2 ' _ 1 �600nJm,2 — mowt,a2 *Specifications included in this data a e Section A -A 7 35.0 f 5 0 > v J � 25C —45r — sheet are subject to change without prior notice. About Canadian Solar Canadian Solar Inc. is one of the world's largest solar companies. As a leading vertically- integrated manufacturer of ingots, wafers, cells, solar modules and solar systems, Canadian Solar delivers solar power products of uncompromising quality to worldwide customers. Canadian Solar's world class team of professionals works closely with our customers to provide them with solutions for all their solar needs. EN -Rev 10.17 Copyright 0 2012 Canadian Solar Inc. Temperature Characteristics Temperature Coefficient Pmax - 0.43 % /°C Voc -0.34 %/•C [so 0.065 %/-C Normal Operating Cell Temperature 45t2•C Performance at Low Irradiance Industry leading performance at low Irradiation environment, +95.5% module efficiency from an Irradiance of 1000w /m2 to 200w /m' (AM 1.5, 25 -C) Engineering Drawings CUPERTINO Building Depa. tfnent Canadian Solar was founded In Canada in;- nd wig { J successfully listed on NASDAQ Exchange (si owl 4hy' November 2006. Canadian Solar has module manufacturing capacity of 2.0513W and cell manufacturing capacity of 1.3GW.