Loading...
11040141 - MISC COMPRESSION TEST REPORT u C W (ASTM C42) ( yq F'7; 5� Q 2U 11 To: t:y Western Athletic Club, Inc. Project No.: 04611095 Edgar Elliott Z Re: Bay Club Silicon Valley 1 Lombard Street A 0101 Nortfi Wolfe Road San Francisco, CA 94111 Cupertino, CA ' l D MIX DATA ...............................................................•:•!:•./:•:•:•:�::.......ev4/...................... Specimen: Shotcrete Mix Design#: R70138C1 Supplier: Central SAMPLE DATA .................................................................................................. Ground Floor Level Columns & Beam Grid Line: L Between 6& 7 Date: 01/26/12 Sampled by: 11896 Design Strength, psi: 4000 LABORATORY DATA .......................................................................................... Specimen No. 94418-1 94418-2 94418-3 94418-4 Date Tested: 2/23/2012 2/23/2012 2/2.3/2012 Moisture Condition Dry Dry Dry Length before capping 5.542 5.511 5.408 Diameter 2.735 2.742 2.735 Length after capping 5.759 5.663 5.561 Ratio 2.11 2.07 2.03 Correction Factor: 1 1 1 Area,sq. in.: 5.875 5.905 5.875 Load, lbs.: 28840 28430 27995 Type of Fracture: Type 4 Type 4 Type 4 Comp.Strength, psi: 4910 4810 4770 Core Average 4830 Remarks: The 28 Day Average Test Result Complies With The Respectfully submitted, Minimum Specified Design Requirement. KRAZAN &ASSOCIATES, INC. Materials Testing Division COMPRESSION TEST REPORT (C31, C39, C67, C78, C138, C143, C172, C173, C231, C617, C1019, & C1231) To: Western Athletic Club, Inc. Project No.: 04611095 Edgar Elliott Jl i'' 'Z• f' Re: Bay Club Silicon Valley 1 Lombard Street OBy San Francisco, CA 94111 s 10101 North Wolfe Road Cupertino, CA MIXDATA .......................................................................................................... Specimen: Concrete Mix Design#: 340PC9D1 Supplier: Central Cement Factor,sack: 6sk Ticket#: 18430471 Max.Size Agg., In.: Pea Admixture: 322N SAMPLE DATA .................................................................................................. Elevator Pit Slab& Slab-On-Grade at Line J Around Column @ 1 Slump-Inches(ASTM C143): 4.25 Date Cast: 01/13/12 Air Temp-F: 39 Sampled by: 10649 Mix Temp-F (ASTM C1064): 62 Design Strength, psi: 4000 Unit Weight (ASTM C138): Air Content, % (ASTM C231): LABORATORY DATA .......................................................................................... Specimen No. 94728-1 94728-2 94728-3 94728-4 94728-5 Date Tested: 1/20/2012 2/10/2012 2/10/2012 2/10/2012 Age,days: 7 28 28 28 H Dimensions: 4.00x8.00 4.00x8.00 4.00x8.00 4.00x8.00 4.00x8.00 Area,sq.In.: 12.57 12.57 12.57 12.57 12.57 Ultimate Load, lbs.: 70730 70540 70265 Comp.Strength, psi: 5630 5610 5590 Type of Fracture: Tested By: Average Strength: 5610 Date of Report: 02/17/12 Respectfully submitted, Remarks: The 28 Day Average Test Result Complies With The Minimum Specified Design Requirement. KRAZAN &ASSO IATES, INC. Materials Testing Division