GENERAL LIGHTING IN EACH ROOM CONTAINING A WATER CLOSET AND KITCHENS MUST
PROVIDE A MINIMUM OF 40 LUMENS PER WATT. IN THE KITCHEN THE MOST ACCESSIBLE
SWITCHES) MUST CONTROL THE GENERAL LIGHTING. LIGHTS USED FOR SPECIFIC
DECORATIVE EFFECTS (AND ARE NOT THE ONLY LUMINARIES IN THE KITCHEN) NEED
NOT MEET THIS REQUIREMENT. HOWEVER, THEY MUST BE SEPARATELY SWITCHED FROM
THE GENEML LIGHTING.
- IN THE BATHROOM AREA AS ALTERNATIVE THE 40 LUMENS FIXTURE MAY MEET THIS
REQUIREMENT BY INSTALLING THE FIXTURE IN AN ADJACENT ROOM THAT HAS
COMPLEMENTARY PLUMBING FIXTURES.
SCREW IN FLUORESCENT BULBS CANNOT BE USED TO MEET THIS REQUIREMENT.
WHEN IN DOUBT ABOUT MEETING THIS REQUIREMENT CALL
FRANK R. IANNUCCI, 408-866-1620.
ALL FLUORESCENT BALLAST MUST BE APPROVED BY THE CEC, THIS CAN BE CHECKED
THROUGH THE BUILDING DEPARTMENT ISSUING THE BUILDING PERMIT, THE CALIFORNIA
ENERGY COMMISSION 916-324-3376, OR BY CALLING OUR OFFICE
408-866-1620.
ALL REFRIGERATORS, REFRIGERATOR -FREEZERS AND FREEZERS MUST BE ON THE CEC
APPROVAL LIST THIS CAN BE CHECKED THROUGH THE BUILDING DEPARTMENT ISSUING
THE BUILDING PERMIT, THE CALIFORNIA ENERGY COMMISSION 916-324-3376, OR BY
CALLING OUR OFFICE 408-866-1620.
EQUIPMENT LIST AND INSULATION PLACEMENT NOTE
ADDITION FOR
TANG RESIDENCE
10231 MIRA VISTA RD
CUPERTINO, CA 95014
JOB # 980751
NOTE: MINIMUM HEATING AND COOLING LOAD CALCULATIONS ARE GENERATED BY THE
MICROPAS PROGRAM. THERE ARE OTHER DESIGN FACTORS THAT MUST BE CONSIDERED,
DUCT FLOW, COIL SIZING , OVERSIZING SAFETY MARGIN, ETC. IT IS THE
RESPONSIBILITY OF THE MECHANICAL CONTRACTOR OR WHOEVER DESIGNS AND INSTALLS
THE HEATING AND COOLING SYSTEM TO MAKE THE FINAL DECISION ABOUT THE SIZE OF
THE EQUIPMENT TO BE INSTALLED.
THE HVAC EQUIPMENT USED MUST MEET THE EFFICIENCIES SHOWN IN THE TITLE 24
CALCULATIONS, THESE ARE AS FOLLOWS:
HEATING: NEW FURNACE MUST HAVE AN AFUE EFFICIENCY OF.78.
AIR CONDITIONING: IF AIR-CONDITIONING IS INSTALLED IT MUST HAVE A MINIMUM
SEER OF 10.
HOT WATER HEATER: THE NEW 50 GALLON WATER HEATER WILL BE INSTALLED. THE
WATER HEATER MUST HAVE A .53 ENERGY FACTOR. AND IT MUST
HAVE AN EXTERNAL INSULATION WRAP OF R-12
NOTE: WHEN WRAPPING INSULATION AROUND A WATER HEATER THE MANUFACTURERS
DATA AND RECOMMENDATIONS MUST BE FOLLOWED.
SETBACK THERMOSTAT: A SETBACK THERMOSTAT IS REQUIRED FOR EACH NEW FURNACE.
FAUCETS AND SHOWERHEADS: SHOWERHEADS AND FAUCETS MUST BE ON
THE CEC APPROVAL LISTING IN ORDER TO BE INSTALLED. THIS CAN BE CHECKED
THROUGH THE BUILDING DEPARTMENT ISSUING THE BUILDING PERMIT, THE CALIFORNIA
ENERGY COMMISSION 916-654-4080, OR BY CALLING OUR OFFICE 408-866-1620.
INSULATION PLACEMENT:
INSULATION TO BE INSTALLED MUST MEET CEC QUALITY STANDARDS.
SEE THE ATTACHED CROSS SECTION DRAWING FOR INSULATION PLACEMENT AND
R-VALUES.
ALL NEW VERTICAL GLASS AREAS ARE METAL DOUBLE GLAZED WITH A MAXIMUM U-VALUE
OF 0.75, OR BETTER. THE PATIO SLIDING DOOR MUST HAVE AN U-VALUE OF 0.77
OR BETTER.
NOTE: ALL R-VALUES AND U-VALUES LISTED ARE MINIMUM VALUES AND CAN
BE EXCEEDED.
b.TYP.
10 BUILT U" ROOF
12,
GLAZING,
i
u
II, CAMMR M.
0.
ATTIC SPACE
LIVING SPACE
8, FLR, ABOVE GAKAa
5, GARAGE 5EPAWION WAIL
ADDITION FOR
TANG RESIDENCE
10231 MIRA VISTA RD
CUPERTINO, CA 95014
APPLIC. R-VALUE. INSUL. TYPE
I, TW, FLAT CEILING
A DUCT
CRAX 5PAa
2, VAILTED POOP W/ AT11C
'`�-- 3. VKLT19 ROOF
LYING SPADE
JOB # 980751
TYPICAL
A.EXT WALL
9, %AP
INSULATION
1.
TYPICAL FLAT CEILING
TYP
R-19
INSULATION
BATT
OR
RIGID
2.
VAULTED ROOF W/ATTIC
N/A
INSULATION
BATT
OR
RIGID
3.
VAULTED ROOF NO ATTIC
N/A
INSULATION
BATT
OR
RIGID
4.
EXTERIOR WALL
TYP
R-13
INSULATION
BATT
OR
RIGID
5.
SEPARATION WALL
N/A
INSULATION
BATT
OR
RIGID
6.
WALL BACKING INTO ATTIC
N/A
INSULATION
BATT
OR
RIGID
7.
CRAWL SPACE FLOOR
TYP
R-19
INSULATION
BATT
OR
RIGID
8.
FLOOR ABOVE GARAGE
TYP
R-19
INSULATION
BATT
OR
RIGID
9.
SLAB EDGE INSULATION
N/A
10.
BUILT UP ROOF
N/A
11.
CANTILEVERED FLOOR
TYP
R-19
INSULATION
BATT
OR
RIGID
U-VALUE
12.
GLAZING
TYP
0.75
METAL WINDOWS
FRENCH DOORS
N/A
, OR BETTER
PATIO SLIDING DOORS
TYP
0.77
OR BETTER
13.
SKYLIGHTS
N/A
I OR BETTER
14.
HEATING & COOLING DUCTS
MINIMUM INSL.
R-VALUE 4.2
NOTE: THIS CROSS SECTION IS USED ONLY FOR DIAGRAMMATIC
PURPOSES AND IS NOT A TRUE CROSS SECTION OF THIS PROJECT.
EXISTING & ADDITION
COMPLIANCE
CALCULATION AND
COMPLIANCE RUN
® •
ADDITION WORKSHEET Page 1 ADD
Project Title.......... TANG RESIDENCE Date........ 10/30/98
e
MICROPAS4 v4.51 File-TANG1 Program -ADDITIONS
User#-MP1107 User -Frank R. Iannucci Energy Run -EXISTING PLUS ADDITION
ADDITION WORKSHEET - COMPUTER PERFORMANCE
EXISTING
File Name .................. TANG1
Run Title.. .. ....... EXISTING
Conditioned Floor Area..... 1397 sf
Standard Design Energy Use. 22.76 kBtu/sf-yr
Proposed Design Energy Use. 70.63 kBtu/sf-yr
NEW (EXISTING PLUS ADDITION)
File Name .................. TANG2
Run Title .................. EXISTING PLUS ADDITION
Conditioned Floor Area..... 2881 sf
Sthndard Design Energy Use. 29.21 kBtu/sf-yr
Proposed Design Energy Use. 40.23 kBtu/sf-yr
FLOOR AREA RATIO Floor
Existing New Area
Floor Area Floor Area Ratio
1397 / 2881 = 0.485
ADDITION DESIGN ENERGY USE FOR NEW (EXISTING PLUS ADDITION)
Floor
New Area Existing Existing Addition
Standard Ratio Proposed Standard Design
29.21 + 0.485 x ( 70.63 - 22.76) = 52.42
Note: If (Existing Proposed - Existing Standard) is
negative, this difference is set to zero.
ADDITION ENERGY USE SUMMARY
Energy Use Addition Proposed Compliance
(kBtu/sf-yr) Design Design Margin
New .................... 52.42 40.23 12.19
*** Addition complies with Computer Performance ***
. e �
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R
Project Title.......... TANG RESIDENCE Date........ 10/30/98
P t Add 10231 MIRA VISTA RD *******
rojec ress........
CUPERTINO, CA 95014 *v4.51*
Documentation Author... KIM H. TRUONG ******* Building Permit
Frank R. Iannucci Energy Consultant
21 N Harrison Ave Ste 210 Plan Check Date
Campbell, CA 95008
408-866-1620 Field C ec Date
Climate Zone.. ..... 04
Compliance Method...... MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc.
MICROPAS4 v4.51 File-TANG2 Wth-CTZ04S92 Program -FORM CF-1R
User#-MP1107 User -Frank R. Iannucci Energy Run -EXISTING PLUS ADDITION
Component
TVDe
Wall
Door
Wall
Roof
Floor
Floor
Frame Cavity
Type R-value
Wood R-0
Wood R-0
Wood R-13
GENERAL INFORMATION
Conditioned Floor Area.....
Building Type ..............
Construction Type .........
Building Front Orientation.
Number of Dwelling Units...
Number of Stories.. ......
Floor Construction Type....
Glazing Percentage.........
Average Glazing U-value....
2881 sf
Single Family Detached
Existing Plus Addition
Front Facing 90 deg (E)
1
2
Raised Floor
19 8 of floor area
0.89 Btu/hr-sf-F
BUILDING SHELL INSULATION
Sheathing Insul Assembly
R-value R-value U-value Location/Comments
R-0 R-0
R-n/a R-0
R-0 R-13
Wood R-19 R-0 R-19
Wood R-0 R-0 R-0
Wood R-19 R-0 R-19
FENESTRATION
0.386 TYP EXT WALL
TO GARAGE
0.330 ENTRY SOLID
TO GARAGE
0.088 TO GARAGE
TYP ADD WALL
0.051 FLAT/TO ATTIC
0.097 RAISED
0.037 RAISED, ABOVE GARAGE
CANTILEVERED
# of
Interior
Over -
Area
U-
Pan-
Shading/
Exterior
hang/ Framing
Orientation
(sf)
Value
es
Description
Shading
Fins
Type
Window
Right
(N)
40.0
1.190
1
Drapes.Std
None
None
Metal
Window
Front
(E)'
71.5
1.190
1
Drapes.Std
None
None
Metal
Window
Left
(S)
24.0
0.750
2
Drapes.Std
None
None
Metal
Window
Back
(W)
49.0
1.190
1
Drapes.Std
None
None
Metal
Window
Back
(NW)
8.0
1.190
1
Drapes.Std
None
None
Metal
Window
Right
(NE)
8.0
1.190
1
Drapes.Std
None
None
Mdtal
Window
Right
(N)
68.0
0.750
2
Drapes.Std
None
None
Metal
Window
Front
(E)
90.5
0.750
2
Drapes.Std
None
None
Metal
Window
Left
(S)
62.5
0.750
2
Drapes.Std
None
None
Metal
Window
Back
(W)
87.0
0.750
2
Drapes.Std
None
None
Metal
Door
Right
(N)
40.0
0.770
2
Drapes.Std
None
None
Metal
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R
Project Title.......... TANG RESIDENCE Date........ 10/30/98
MICROPAS4 v4.51 File-TANG2 Wth-CTZ04S92 Program -FORM CF-1R
User#-MP1107 User -Frank R. Iannucci Energy Run -EXISTING PLUS ADDITION
HVAC SYSTEMS
Minimum
Duct
Duct
Thermostat
Equipment Type
Efficiency
Location
R-value
Type
Furnace
0.780 AFUE
Attic
R-4.2
Setback
ACSplit
10.00 SEER
Attic
R-4.2
Setback
Furnace
0.780 AFUE
Attic
R-4.2
Setback
ACSplit
10.00 SEER
Attic
R-4.2
Setback
WATER
HEATING SYSTEMS
Tank Type Heater Type
Storage Gas
Number
in Energy
Distribution Type System Factor
Standard 1 0.53 EF
SPECIAL FEATURES/REMARKS
JOB # 980751
ALL INSULATION VALUES ARE MINIMUM REQUIREMENTS. SEE
PLANS TO VERIFY ACTUAL INSULATION VALUES TO BE INSTALLED.
Tank External
Size Insulation
(gal) R-value
50 R-12
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-lR
Project Title.......... TANG RESIDENCE Date........ 10/30/98
MICROPAS4 v4.51 File-TANG2 Wth-CTZ04S92 Program -FORM CF-lR
User#-MP1107 User -Frank R. Iannucci Energy Run -EXISTING PLUS ADDITION
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title-24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features/
Remarks section.
DESIGNER or OWNER
Name.... THU HA NGUYEN
Company. BUILDING DESIGNER
Address. 2849 BURDICK WAY
SAN JOSE, CA 95148
Phone... 408-238-4577
License.
Signed..
(d ate)
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed..
( ate)
DOCUMENTATION AUTHOR
Name.... KIM H. TRUONG
Company. Frank R. Iannucci Energgyy Consult
Address. 21 N Harrison Ave Ste 210
Campbell, CA 95008
Phone... 408-866-1620 _
Signed. .
(date)
•
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF-1R
Project Title.......... TANG RESIDENCE Date........ 10/30/98
Project Address........ 10231 MIRA VISTA RD
CUPERTINO, CA 95014 *v4.51*
Documentation Author... KIM H. TRUONG ******* Building Permit
Frank R. Iannucci Energy Consultant
21 N Harrison Ave Ste 210 Plan cFe-FR%Date
Campbell, CA 95008
408-866-1620 Field C ec Date
Climate Zone. ..... 04
Compliance Method...... MICR0PAS4 v4.51 for 1995 Standards by Enercomp, Inc.
MICROPAS4 v4.51 File-TANG2 Wth-CTZ04S92 Program -FORM MF-1R
User#-MP1107 User -Frank R. Iannucci Energy Run -EXISTING PLUS ADDITION
Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. Items marked with an
asterisk (*) may be superseded by more stringent compliance requirements listed
on the Certificate of Compliance. When this checklist is incorporated into the
permit documents, the features noted shall be considered by all parties as
binding minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
Design- Enforce-
er ment
*150(a): Minimum R-19 ceiling insulation.
150(b): Loose fill insulation manufacturers labeled R-Value.
*150(c): Minimum R-13 wall insulation in framed walls
(does not apply to exterior mass walls).
*150fd2: Minimum R-13 raised floor insulation in framed floors;
minimum R-8 in concrete raised floors.
✓
150(i): Slab edge insulation - water absorption rate no greater
than 0.3%, water vapor transmission rate no greater than 2.0
perm/inch.�G
118: Insulation specified or installed meets CEC quality
standards. Indicate type and form.
t%
116-17: Fenestration Products, Exterior Doors and Infiltration/
exfiltration controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
b. Manufactured fenestration products have label with
certified U-value, and infiltration certification.
c. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed.
1500(g): Vapor barriers mandatory in Climate Zones 14 and 16
N/
150(f): Special infiltration barrier installed to comply with
��
Sec. 151 meets CEC quality standards.
150(e): Installation of Fireplaces, Decorative Gas Appliances
and gas logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
E
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF-1R
Project 'title.......... TANG RESIDENCE Date........ 10/30/98
MICROPAS4 v4.51 File-TANG2 Wth-CTZ04S92 Program -FORM MF-1R
User#-MP1107 User -Frank R. Iannucci Energy Run -EXISTING PLUS ADDITION
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
Design- Enforce-
er went
110-13: HVAC equipment, water heaters, showerheads and faucets
certified by the CEC.
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA.
150(i): Setback thermostat on all applicable heating systems._
150(j): Pipe and Tank insulation
1. Indirect hot water tanks (e.g., unfired storage tanks or
backup solar hot water tanks) have insulation blanket (R-12
or greater) or combined interior/exterior insulation (R-16
or greater).
2. First 5 feet of pipes closest to water heater tank, non -
recirculating systems, insulated (R-4 or greater).
3: All buried or exposed piping insulated in recirculating
sections of hot water system.
4. Cooling system piping below 55 degrees insulated.
5. Piping insulated between heating source and indirect
hot water tank.
✓
*150(m): Ducts and Fans
1. Ducts constructed, installed and sealed to comply with UMC
sections 601 and 603; ducts insulated to a minimum
installed value of R-4.2 or ducts enclosed entirely within
conditioned space.
2. Exhaust fan systems have backdraft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually
✓
operated dampers.
114: Pool and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on -off
switch, weatherproof operating instructions, no electric
resistance heating and no pilot light.
2. System.installed with:
a. At least 36 inches pipe between filter and heater for
future solar heating.
b. Cover for outdoor pools or outdoor spa.
3. Pool system has directional inlets and a circulation
pump time switch.
115: Gas -fired central furnace, pool heater, spa heater or
household cooking appliance have no continuously burning
pilot light (Exception: Non -electrical cooking appliance
with pilot < 150 Btu/hr.).
LIGHTING MEASURES
Design- Enforce-
eir went
150(k): 40 lumens/watt or greater for general lighting in
kitchens and rooms with water closets; and recessed ceiling ✓✓✓/
fixtures IC (insulation cover) approved.
COMPUTER METHOD SUMMARY Page 1 C-2R
Project Title.......... TANG RESIDENCE Date........ 10/30/98
* *****
Project Address........ 10231 MIRA VISTA RD
CUPERTINO, CA 95014 *v4.51*
Documentation Author... KIM H. TRUONG ******* Building Permit
Frank R. Iannucci Energy Consultant
21 N Harrison Ave Ste 210 Plan C ec Date
Campbell, CA 95008
408-866-1620 Field Check7 Date
Climate Zone.. ..... 04
Compliance Method...... MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc.
MICROPAS4 v4.51 File-TANG2 Wth-CTZ04S92 Program -FORM C-2R
User#-MP1107 User -Frank R. Iannucci Energy Run -EXISTING PLUS ADDITION
MICROPAS4 ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating..........
11.49
21.00
-9.51
Space Cooling..........
8.65
10.17
-1.52
Water Heating..........
9.07
9.06
0.01
Total 29.21
40.23
-11.02
*** Building
does not comply with
Computer Performance ***
GENERAL INFORMATION
Conditioned Floor Area..... 2881 sf
Building Type .............. Single Family Detached
Construction Type ......... Existing Plus Addition
Building Front Orientation. Front Facing 90 deg (E)
Number of Dwelling Units... 1
Number of Building Stories. 2
Weather Data Type.......... ReducedYear
Floor Construction Type.... Raised Floor
Number of Building Zones... 2
Conditioned Volume......... 25929 cf
Footprint Area ............. 1794.5 sf
Ground Floor Area.......... 1794.5 sf
Slab -On -Grade Area......... 0 sf
Glazing Percentage......... 19 8 of floor area
Average Glazing U-value.... 0.89 Btu/hr-sf-F
Average Ceiling Height..... 9 ft
BUILDING ZONE INFORMATION
Floor
t of
Vent
Special
Area
Volume
Dwell
Cond-
Thermostat
Height
Vent Area
Zone Type
(�f)
(cf)
Units
itioned
Type
(ft)
(of)
EXISTING
Residence
1397
12573
0.48
Yes
Setback
2.0
n/a
ADDITION
Residence
1484
13356
0.52
Yes
Setback
8.0
n/a
COMPUTER METHOD SUMMARY Page 2 C-2R
Project Title.......... TANG RESIDENCE Date........ 10/30/98
MICROPAS4 v4.51 File-TANG2 Wth-CTZ04S92 Program -FORM C-2R
User#-MP1107 User -Frank R. Iannucci Energy Run -EXISTING PLUS ADDITION
OPAQUE SURFACES
Area U- Insul Act Solar Form 3
Surface (sf) value R-val Azm Tilt Gains Reference
EXISTING
- Existing
1
Vall
174
2
Va11
181
3
Vall
40
4
Wall
214
5
Door
40
6
Door
18
7
Wall
118
8
Wall
168
9
Wall
12
10
Rall
12
11
Roof
351
12
Floor
1167
ADDITION -
New
13
%all
430
14
Wall
270
15
Wall
460
16
Wall
379
17
R-oof
1493
18
Floor
342
19
Floor
226
20
Floor
60
Location/
Comments
0.386
0
0
90
Yes
W.0.2X4.16
TYP EXT WALL
0.386
0
90
90
Yes
W.0.2X4.16
TYP EXT WALL
0.386
0
180
90
Yes
W.0.2X4.16
TYP EXT WALL
0.386
0
270
90
Yes
W.0.2X4.16
TYP EXT WALL
0.330
0
90
90
Yes
None
ENTRY SOLID
0.330
0
90
90
No
None
TO GARAGE
0.088
13
90
90
No
W.13.2X4.16
TO GARAGE
0.386
0
ISO
90
No
W.0.2X4.16
TO GARAGE
0.386
0
315
90
Yes
W.0.2X4.16
TYP EXT WAIL
0.386
0
45
90
Yes
W.0.2X4.16
TYP EXT WALL
0.051
19
n/a
0
Yes
R.19.2X8.16
FLAT/TO ATTIC
0.097
0
n/a
0
No
FC.0.2X6.16
RAISED
0.088
13
0
90
Yes
W.13.2X4.16
TYP ADD WALL
0.088
13
90
90
Yes
W.13.2X4.16
TYP ADD WALL
0.088
13
L80
90
Yes
W.13.2X4.16
TYP ADD WALL
0.088
13
270
90
Yes
W.13.2X4.16
TYP ADD WALL
0.051
19
n/a
0
Yes
R.19.2X8.16
FLAT/TO ATTIC
0.037
19
n/a
0
No
FC.19.2X8.16
RAISED
0.037
19
n/a
0
No
FC.19.2X8.16
ABOVE GARAGE
0.037
19
n/a
0
No
FC.19.2X8.16
CANTILEVERED
FENESTRATION
SURFACES
# of
Area Pan- Frame
Surface (sf) es Type
EXISTING - Existing
1 Window 40.0 1
2 Window 71.5 1
3 Window •24.0 2
4 Window 49.0 1
5 Window 8.0 1
6 Window 8.0 1
ADDITION - New
7 Window 68.0 2
8 Window 90.5 2
9 Window 62.5 2
10 Window 87.0 2
11 Door 40.0 2
Vent Sc SC Interior
Open U- Act Glass Int Shading/
Type value Azm Tlt Only Shade Description
Metal
Slider
1.190
0
90
1.00
0.78
Drapes.Std
Metal
Slider
1.190
90
90
1.00
0.78
Drapes.Std
Metal
Slider
0.750
180
90
0.88
0.78
Drapes.Std
Metal
Slider
1.190
270
90
1.00
0.78
Drapes.Std
Metal
Slider
1.190
315
90
1.00
0.78
Drapes.Std
Metal
Slider
1.190
45
90
1.00
0.78
Drapes.Std
Metal
Slider
0.750
0
90
0.88
0.78
Drapes.Std
Metal
Slider
0.750
90
90
0.88
0.78
Drapes.Std
Metal
Slider
0.750
180
90
0.88
0.78
Drapes.Std
Metal
Slider
0.750
270
90
0.88
0.78
Drapes.Std
Metal
Slider
0.770
0
90
0.88
0.78
Drapes.Std
COMPUTER METHOD SUMMARY Page 3 C-2R
Project Title.......... TANG RESIDENCE Date........ 10/30/98
MICROPAS4 v4.51 File-TANG2 Wth-CTZ04S92 Program -FORM C-2R
User#-MP1107 User -Frank R. Iannucci Energy Run -EXISTING PLUS ADDITION
System Type
EXISTING
Furnace
ACSplit
ADDITION
Furnace
ACSplit
Tank Type Heater Type
1 Storage Gas
HVAC SYSTEMS
Minimum Duct Duct Duct
Efficiency Location R-value Efficiency
0.780 AFUE Attic R-4.2
10.00 SEER Attic R-4.2
0.780 AFUE Attic R-4.2
10.00 SEER Attic R-4.2
WATER HEATING SYSTEMS
Number
in Energy
Distribution Type System Factor
Standard 1 0.53
SPECIAL FEATURES/REMARKS
JOB # 980751
ALL INSULATION VALUES ARE MINIMUM REQUIREMENTS. SEE
PLANS TO VERIFY ACTUAL INSULATION VALUES TO BE INSTALLED.
0.880
0.870
0.880
0.870
Tank External
Size Insulation
(gal) R-value
50 R-12
EXISTING RESIDENCE
BUDGET INFORMATION
COMPUTER METHOD SUMMARY Page 1 C-2R
Project Title.......... TANG RESIDENCE Date........ 10/30/98
dd
Project A ress........ 10231 MIRA VISTA RD
CUPERTINO, CA 95014 *v4.51*
Documentation Author... KIM H. TRUONG ******* Building Permit
Frank R. Iannucci Energy Consultant
21 N Harrison Ave Ste 210 Plan Check T Date
Campbell, CA 95008
408-866-1620 Field C ec Date
Climate Zone.. ..... 04
Compliance Method...... MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc.
MICROPAS4 v4.51 File-TANG1 Wth-CTZ04S92 Program -FORM C-2R
User#-MP1107 User -Frank R. Iannucci Energy Run -EXISTING
MICROPAS4 ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating..........
11.07
46.21
-35.14
Space Cooling..........
11.69
24.42
-12.73
Total 22.76
70.63
-47.87
*** Water Heating not
calculated ***
Zone Type
EXISTING
Residence
GENERAL INFORMATION
Conditioned Floor Area..... 1397 sf
Building Type .............. Single Family Detached
Construction Type ......... Existing
Building Front Orientation. Front Facing 90 deg (E)
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... ReducedYear
Floor Construction Type.... Raised Floor
Number of Building Zones... 1
Conditioned Volume......... 12573 cf
Footprint Area ............. 1397 sf
Ground Floor Area.......... 1397 sf
Slab -On -Grade Area......... 0 sf
Glazing Percentage......... 15.2 8 of floor area
Average Glazing U-value.... 1.19 Btu/hr-sf-F
Average Ceiling Height..... 9 ft
BUILDING ZONE INFORMATION
Floor
i of
Area
volume Dwell Cond- Thermostat
(sf)
(cf) Units itioned Type
1397
12573 1.00 Yes NoSetback
Vent Special
Height Vent Area
(ft) (sf)
2.0 n/a
COMPUTER METHOD SUMMARY Page 2 C-2R
Project Title.......... TANG RESIDENCE Date........ 10/30/98
MICROPAS4 v4.51 File-TANG1 Wth-CTZ04S92 Program -FORM C-2R
User#-MP1107 User -Frank R. Iannucci Energy Run -EXISTING
OPAQUE
SURFACES
Area
U-
Insul Act
Solar
Form 3 Location/
Surface
(sf)
value
R-val Azm Tilt Gains
Reference Comments
EXISTING -
Existing
1
Wall
200
0.386
0 0
90 Yes
W.0.2X4.16 TYP EXT WALL
2
Wall
299
0.386
0 90
90 Yes
W.0.2X4.16 TYP EXT WALL
3
Wall
236
0.386
0 180
90 Yes
W.0.2X4.16 TYP EXT WALL
4
Wall
377
0.386
0 270
90 Yes
W.0.2X4.16 TYP EXT WALL
5
Door
20
0.330
0 90
90 Yes
None ENTRY SOLID
6
Roof
1397
0.051
19 n/a
0 Yes
R.19.2X8.16 FLAT/TO ATTIC
7
Floor
1397
0.097
0 n/a
0 No
FC.0.2X6.16 RAISED
FENESTRATION SURFACES
# of
Vent
SC SC Interior
Area Pan-
Frame
Open
U- Act
Glass Int Shading/
Surface
(sf) es
Type
Type
value Azm
Tlt Only Shade Description
EXISTING -
Existing
'
1
Window
40.0 1
Metal
Slider
1.190 0
90 1.00 0.78 Drapes.Std
2
Window
113.0 1
Metal
Slider
1.190 90
90 1.00 0.78 Drapes.Std
3
Window
4.0 1
Metal
Slider
1.190 180
90 1.00 0.78 Drapes.Std
4
Window
54.8 1
Metal
Slider
1.190 270
90 1.00 0.78 Drapes.Std
HVAC
SYSTEMS
Minimum
Duct
System Type
Efficiency
Location
EXISTING
Furnace
0.750 AFUE
Attic
ACSplit
8.00 SEER
Attic
SPECIAL FEATURES/REMARKS
JOB # 980751
Duct Duct
R-value Efficiency
R-2.1 0.780
R-2.1 0.740
HVAC SIZING Page 1 HVAC
Project Title.......... TANG RESIDENCE Date........ 10/30/98
P t Add 10231 M RA V S *******
r0
MICROPAS4 v4.51 File-TANG2 Wth-CTZ04S92 Program-HVAC SIZING
User#-MP1107 User -Frank R. Iannucci Energy Run -EXISTING PLUS ADDITION
GENERAL INFORMATION
Floor Area.........._......
2881 sf
Volume.. ...........
25929 cf
Front Orientation..........
Front Facing
90 deg (E)
Sizing Location............
CUPERTINO
Latitude.. ._......
37.3 degrees
Winter Outside Design......
33 F
Winter Inside Design.......
70 F
Summer Outside Design......
88 F
Summer Inside Design.......
78 F
Summer Range.. ......
30 F
Interior Shading Used......
No
Exterior Shading Used......
No
Overhang Shading Used......
No
Latent Load Fraction.......
0.20
HEATING AND COOLING
LOAD SUMMARY
Heating
Cooling
Description
(Btuh)
(Btuh)
Opaque Conduction and Solar......
26122
6127
Glazing Conduction ...............
18124
4898
Glazing Solar ....................
n/a
21913
Infiltration .....................
17804
2124
Internal Gain ....................
n/a
3450
Ducts ............................
6205
3851
Sensible Load ....................
68255
42363
Latent Load ......................
n/a
8473
Minimum Total Load
68255
50836
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designet's responsibility to consider all factors when selecting
the HVAC equipment.
HVAC SIZING Page 2 HVAC
Project Title.......... TANG RESIDENCE Date........ 10/30/98
MICROPAS4 v4.51 File-TANG2 Wth-CTZ04S92 Program-HVAC SIZING
User#-MP1107 User -Frank R. Iannucci Energy Run -EXISTING PLUS ADDITION
HEATING AND COOLING LOAD SUMMARY BY ZONE
ZONE 'EXISTING'
Floor Area .......................
1397 sf
Volume ...........................
12573 cf
Heating
Cooling
Description
(Btuh)
(Btuh)
Opaque Conduction and Solar......
Glazing Conduction ...............
17397
8437
2738
2280
Glazing Solar ....................
n/a
9211
Infiltration .....................
8633
1030
Internal Gain ....................
n/a
1656
Ducts ............................
3447
1691
Sensible Load ....................
37915
18606
Latent Load ......................
n/a
3721
Minimum Zone Load
37915
22328
ZONE 'ADDITION'
Floor Area .......................
1484 sf
Volume ...........................
13356 cf
Heating
Cooling
Description
(Btuh)
(Btuh)
Opaque Conduction and Solar......
8725
3389
Glazing Conduction ...............
9687
2618
Glazing Solar ....................
n/a
12703
Infiltration .....................
9171
1094
Internal Gain ....................
n/a
1794
Ducts ............................
2758
2160
Sensible Load ....................
30340
23757
Latent Load ......................
n/a
4751
Minimum Zone Load
30340
28508
' I
GENE WONG P.E.
` 3583 Rollingside Drive, San Jose, Calif. 95148
(408) 274-7782
V.�'4�0Iif,: Foy co0MUaYS
I ST' y uc �-ro izY AODIT t o Q
IT 10 -;- 31 M I tz A VI s IZDkr�,7
JAN 141999
t3L 'dN ECTION DEFAR"IMEW
F CUPERTINO
ic m
No. C043`39 A
�r t 1, -
--
Building Department - ---`
AJditivt:
! 0?31 \ ir? Vis a
conuol rc O064
Permit d S3095
Rr`'hecked by Bnice
1 ATjAc112o Aur, QEvlS6t2 e�7A1L
5
[tern 19 provided.
,tern 20: Nut addressed .`ully C,).--neCt 2I39 to wall/diaphragm.
Item 24, Show.liandnil calculimunL. L SEE (ZEVISEb v No ,
ATTACOVO Awo k6v+ 3
liEti� � 1�
y , �
21-> 0"
i
o,
=3�y
S
W=l•Y�I.sS,cvl,c,�o='S9ob'I
1.1 57 At�ll,lt�( ,
Mo = 3565 = 338b8'
1Y+35r)1 �.�Y'r
5 1-�, 303 13
338b$
�ii.� dolt, pt�E�ui2� •.
X= 1:903 — 33 86
s � 1.•v5 ,� S,S g
GkU-�. M t I I •r � �'d ,! 14' f 1. , � �C 14• _ � k
�3 - z a• `I' S �S
i
0�5-v 115 ,tzo
• �M= 09 �to�jy,tl,o ,c (14:S,ti•ib�z� _ �I.K ) ��1�,
1 v OK
C- 44U-K 2Al l�
11'Ll oK-.
µex
(L (20La
�b 4so(li)�I Z = 49op,,
P-AI L To PoST ((344U'1
Co/Br.�
_- -i•�
1C fo_."vnit—
A cjD
ArFu..iJA� Lk y, 5A. t 7S' La
' �(T
,t/ _ / 201-7 S . . /' (-
US& Mlnl. 2- (04 'rp IVA IL S
M = �-Lz`a �4) 430 Ft•.c
4-, _ `f-Bo(1-0/I./ a//ps) J
po�T l'U f'iEL�M LoNti1EC'IiL��ll _
�, ito L- i Ilo (54
0 wn:itc✓1. DtliS166 DIA.—
Dct i' /`$-Dt OsA c `/ES i 'A = 19.-/
, G f-
11
RECORDING REQUESTED BY:
WHEN RECORDED NI IAIL TO:
l J 1 3/ Yi v Sfa. R.' 8
DECLARATION OF RESTRICTIONS
This DECLARATION OF RESTRICTIONS made this /7 day of , uc.e.-Abe ,-
1992-- by Ch , cu i. n o , hereinafter referred to as "declarant."
WHEREAS, Declarant is the owner of certain real property located in the City of
Cupertino, County of Santa Clara, California, more particularly described as follows:
APN _ 3.53 - O 24- 03.E (Legal description attached as Exhibit A.)
WHEREAS, Declarant and/or persons acting on behalf of Declarant propose to construct a
second dwelling unit on an existing single-family lot.
WHEREAS, Chapter 19.84, an Ordinance of the City of Cupertino regulates the
construction and maintenance of second dwelling units in single family (RI)zones as
follows:
1. The owner must reside on the premises in the principal or second dwelling
unit.
2. A deed restriction setting forth the above -described occupancy
requirement must be recorded prior to granting a building permit for a new
dwelling unit or granting an occupancy permit for an existing second unit
constructed prior to the adoption of the second unit regulations.
3. The owner of a property which contains a second dwelling must sign an
affidavit on each yearly anniversary date of the approval of said second unit
declaring under perjury that he/she is living on the premises.
4. In the event the owner is unable to reside on the premises for any reason,
continued occupancy of two units on the property is invalid and illegal. Only
one of the units may be non -owner occupied and the other second unit must
be rendered unoccupiable, except as an accessory building as permitted by
the R1, residential single family, zoning district of the City of Cupertino.
5. In that event, the second unit must be modified to conform with the
accessory building provisions of the R1 Ordinance by elimination of the food
preparation capability within the kitchen area including the removal of
cooking units including range and ovens and disconnection of special
electrical wiring and/or gas lines to service said kitchen area.
6. In lieu of eliminating the food preparation facilities, the owner of the
property has the option of leaving one of the two units vacant.
7. Certification of removal of the functional food preparation facilities must
be made by inspection by the City of Cupertino Building Department prior to
non -owner occupancy of the property. An inspection fee will be charged to
certify that the modifications have been completed.
8. If the owner elects to leave one of the units vacant, the owner must
prepare a letter describing the unit and the length of time it will remain
vacant. The unit must be subject to periodic inspections by the City to
confirm that it is not occupied.
NOW, THEREFORE, in consideration of, and subject to, the terms and conditions set
forth above, Declarant agrees as follows:
Declarant agrees to comply with the above referenced conditions and restrictions and
hereby notices all future property buyers of said conditions.
Declarant agrees that this declaration is intended to be a covenant running with the land and
will bind and inure to the benefit of the heirs, personal representatives, successors and
assigns of each present and future owner of the real property described herein.
Dated: I % �L
Declarant
All Signatures must be Acknowledged
•
CALIFORNIA ALL-PURPOSE ACKNOWLEDGMENT
State of California
ti ss.
5 County of SSvn(t ClGtlt`
t
ti
n
On�ftQiU�O:Y %—Iqf before me, PO-42 R 6,1 --�(L � �J/iG
Date j Name and Titre of Cffi— .'Jane Doe. Nota P.15W)
n personally appeared C�' �• - N51 n Tao
jj N-0) of Signer(,)
1
<}
i✓ personally known to me
n
proved to me on the basis of satisfactory
h
evidence
n,
to be the person() whose name(A rLsYafe
subscribed to the with instrument and
HA[ R. CHCi �►+}1
acknowledged to me tha he MC/thEy executed
n _ Commission = 1167564
`
the same in is heHtherrthorized
-� NCalifornia—CD`oi
capacity(i), andc that by hherkheir
Sonic C'o'o Cc'-ny
'
signature(%) on the instrument the person(�r), or
MYCC^�ErLres.ci3;.2002
i
the entity upon behalf of which the person)
acted, executed the instrument.
p WITNESS my hand and official sea
I Y A // / L
Place Notary Seal AW- Sgnature of Notary Puhed
OPTIONAL
? Though the information below is not required by law, It may prove valuable to persons relying on the document
and could prevent fraudulent removal and reattachment of this form to another document.
Description of Attached Documgnt
ti Title or Type of Document: t)P c(Ara REsn c
Document Date: f Number of Pages: y
} Signer(s) Other Than Named Above.
ti
Capacity(ies) Claimed lb Signer
Signer's Name: l� h i cs —
n ,5 Individual Top of thumb here
ED 5
Corporate Officer — Title(s):
s ❑ Partner — ❑ Limited General
Attorney in Fact
Trustee
h
❑ Guardian or Conservator
y ❑ Other:
Signer Is Representing:
LJ
It 1997 Natant Notary Association • 9750 De Soto Ave PO gas 2402 • Chats —it, CA 91313 2402 Prod No WIT Reorder Calt Toe.Free 1 e00.976 6827
CLTA Standard Policy - 1990 Form Order No. 1807986
Policy No. 27-01-90 279107
EXHIBIT "ONE"
Lot 45, as shown on that certain Map entitled "Tract No. 1113", which Map was filed for record in the
Office of the Recorder of the County of Santa Clara, State of California, on February 09, 1954 in Book
48 of Maps at page(s) 8 and 9.
Assessor's Parcel No: 357-02-032
PLEASE KEEP
•
1
err 4•i�
f
•jl
Ordinance No. 1799
CITY OF CUPERTINO
10300 Torre Avenue Telephone 777-3228
INSPECTION NOTICE
�fBUILDING DIVISION p
JOB -JC / '. , � /C DATE 0
ADDRESS j31 �Ila /� TIME
DAILY REPORT ❑ CORRECTION NOTICE v10LATION ❑
TYPE INSP.: BLDG < ELEC. ❑ PLBG. ❑ MECH. ❑
❑ STOP WORK ❑ REINSPECTION FEE
%CJ Gz 0 10125L1
f1 �¢iclh)C,Yi�
refundable, to the
the Director shall
Community De
ve
,• manner as provide
a public hearing,; —
mandatory finding S^��
Community Deve
application for an �(j <S Imo' T .--
Development ma}
Section 19.136.0
C. An exception whi
date thereof, shall•
period shall speci:
variance. An exce
event of the erecti
occurred and cont
extension may be WEATHER INSP.
application is filet
19.124.100(D).
D. In addition to any,
and maintain acie CARD TO REMAIN O JOB -SITE
conditions attache
this chapter.
II. EXEMPTION
e provisions of this ordinance shall not apply to any building for which a
building t
application for
permit was accpted a new second story building or i� «�)
addition on or before Au t 31 and issued by February 18, 1999.
The privacy protection requirements for window alignment contained in Section
^
19.28.F.2 are not required for any building for which a building permit
application was accepted for a new second story building or addition between
September 1, 1998 and November 5, 1998.
`
Any exemption hereunder applies only to the original applicant. , rivari ; i�
III. PUBLICATION �� L
The City Clerk shall cause this ordinance to be published at least once in a
newspaper of general circulation published and circulated in the City within 15 days
after its adoption, in accordance with Government code § 36933, shall certify to the
adoption of this ordinance and shall cause this ordinance and her certification,
together With proof of publication, to be entered in the Book of Ordinances of the
Council of this City.
6W4CIE
MAR 23
L-Ivl,-� RUM
QED L�r 1 l V r CLL V 1-� 1 1LJ 1. SCALE 1/4,
0
'ELEVATION SCALE 1/4' =
Cate
Scale F
Cr2wn-
Sheet
f
O: E
3ED LEE 1 5)Itjh r,Lr. V t,�, 1 1\J1 v SCALE 1W
•
I�
i
.ELEVATION SCALE 1l4' = V -D
s�
F F To
-roP of
r.A,:.
0
z
z
r�.
i
Q
L
w T \
z v
O
w i-r
z
Q
z
F-
O
W
O
a
Dale C
Scale µ
Drawn ltt
Job Ct-kl
Sheet
A
OL 6
.ELEVATION SCALE 1l4' = V -D
s�
F F To
-roP of
r.A,:.
0
z
z
r�.
i
Q
L
w T \
z v
O
w i-r
z
Q
z
F-
O
W
O
a
Dale C
Scale µ
Drawn ltt
Job Ct-kl
Sheet
A
OL 6
TreeWorld
P.O. Box 1 111 Santa Clara, CA 95052
408-984-8812
State Contractors lic #738961
ARBORIST REPORT
of
A proposed: single family residence
/&Z-3/
Located at: 10213 Mira Vista Road
Cupertino, CA
Prepared for:
Tang
C'p '4 — //SM/
As of: September 1, 1999
By: Kenneth R. Sanford, Certified Arborist #ISA-WC-2243
TreeWorld •
P.O. Box 1 111 Santa Clara, CA 95052
408.984-8812
State Contractors lic #738961
Introduction
Ken R. Sanford (TreeWorld) was requested by Charles Tang to inspect,
evaluate and report on trees located at 10231 Mira Vista Road, Cupertino,
Calif. This report is intended to provide evidence of compliance for
ordinance No. 1799 of the City Council of the City of Cupertino (privacy
protection requirements) Pictures provided correspond with site map (See
"Exhibit A"). The following is our findings and recommendations.
Method of Evaluation
1. Record location of each tree on site map.
2. Identity each tree as to species.
3. Measure trunk diameter at point 48" above grade.
4. Evaluate tree health of the tree on a 0 - 5 scale, where 0 = poor
and 5 = excellent condition.
5. Note any areas of structural weakness such as decay, cracks, poor crown
conformation, history of failure, etc.
Description of Trees
A total of 3 trees were evaluated which includes the following:
Common Name Scientific Name No. of Trees
Live Oak Quercus agrifolia
Mulbury Mulbury
Cherry Plum Prunus cerasifera
TreeWorld 0
P.O. Box 1111 Santa Clara, CA 95052
408-984-8812
State Contractors lic #738961
Tree number ( 1 )
Type: live Oak
Trunk diameter at 4 ft. = 18"
Canopy diameter: = 30 ft.
Height: — 35 ft.
Health condition: 5
Save
Tree number ( 2 )
Type: Mulbury
Trunk diameter at 4 ft. = 10"
Canopy diameter = 10 ft.
Height: 15'
Health condition: 5
Save
Tree(3)
Type: Flowering Plum
Trunk diameter at 4 ft. = 5"
Canopy diameter = 7 ft.
Height: = 12 ft.
Health condition: 5
Save
`A
TreeWor[d 0
P.O. Box I I l l Santa Clara, CA 95052
408-984-8812
State Contractors lie #738961
Summary
It is the opinion of this arborist that the trees planted and described and evaluated in this
report fully comply with the ordinance No. 1799 of the City of Cupertino. It is also
recommended that no further plantings be required in this area as long as regular
maintenance and yearly health inspection are made by a certified arborist.
The information contained in this report is true and correct to the best of my knowledge.
Changes to the plans and to the site may necessitate the revision to the information
contained herein.
TreeWorld
r
Ken R. Sanford
Arborist #ISA-2243
Tres171 1 x I
AS
-- _
� q I
5�40 d i ,-� - - f - - --fir x - - •'
'free
reeq = Que.cus Oak
rue$ MOMS hlalberi�
l o•q ZZ
%iee L• Pun�s �3l�rscana � '�rcT ,2g1 �c7���3 Q
Ewa. !I cr,j, �• �� �� o
i
�b
2 1S1'C�j /
I �¢ .4 •� - ^ �I�f• i1i � IZ I I
611 or,
------------
\' E 4" I t •� 1 4
t�
r
l
r.
,r
„
f
/
`i
1
Ordinance No. 1799
Appendix B
Release of Privacv Protection Measures
Single Family Residential Ordinance
Pale 6
Ordinance 19.28 (Single Family) requires that after September 21, 1998, all new two
story additions or homes be required to complete privacy protection measures. A
modification or deletion to these requirements may be granted by staff if the adjacent
affected property owners sign a release agreeing to modify or delete the requirements.
Date
Property Location
Address: 10231 Mira Vista Road, Cupertino, CA 95014
I agree to waive or modify the privacy protection measures required of the Single Family
Residential Ordinance as follows:
I agree to waive the Planting Requirements (Ordinance No. 1799 F.1).
Property Owner.
Address:
Phone:
Signature: —� ` �—
Ordinance No. 1799
•
Appendix B
Release of Privacv Protection Measures
Single Family Residential Ordinance
Page 6
Ordinance 19.28 (Single Family) requires that after September 21, 1998, all new two
story additions or homes be required to complete privacy protection measures. A
modification or deletion to these requirements may be granted by staff if the adjacent
affected property owners sign a release agreeing to modify or delete the requirements.
Date 'C-i/J�
Property Location
Address: 10231 Mira Vista Road, Cupertino, CA 95014
I agree to waive or modify the privacy protection measures required of the Single Family
Residential Ordinance as follows:
I agree to waive the Planting Requirements (Ordinance No. 1799 F.1).
//ewetiii : 4/•i po
Property Owner. CV-) o,r r2s Y .- rc l—
Address: IaazK P40 V,
Phone: 'tD ca-
Signature:
►r
Ordinance No. 1799
n
Appendix B
Release of Privacv Protection Measures
Single Family Residential Ordinance
Page 6
Ordinance 19.28 (Single Family) requires that after September 21, 1998, all new two
story additions or homes be required to complete privacy protection measures. A
modification or deletion to these requirements may be granted by staff if the adjacent
affected property owners sign a release agreeing to modify or delete the requirements.
Date $ l � �' F
Property Location
Address: 10231 Mira Vista Road, Cupertino, CA 95014
I agree to waive or modify the privacy protection measures required of the Single Family
Residential Ordinance as follows:
I agree to waive the Planting Requirements (Ordinance No. 1799 F.1).
Property Owner: %L" — 11IV
1q AIS-
Address: /O /L1 — /1'%Ar_b
Phone: �o $' —
Signature:
0 TreeWorld
P.O. Box 1 11 l Santa Clara, CA 95052
1, 408-984-8812
State Contractors lic #738961
$
ARBORIST REPORT
of
A proposed: single family residence
/0Z 3/
Located at: 10213 Mira Vista Road
Cupertino, CA
Prepared for:
Cam- Tang
Iry
�.vow
As of: September 1, 1999
By: Kenneth R. Sanford, Certified Arborist #1SA-WC-2243
14
0 TreeWorld i
P.O. Box I 1 1 1 Santa Clara, CA 95052
408.984-8812
State Contractors lic #738961
Introduction
Ken R. Sanford (TreeWorld) was requested by Charles Tang to inspect,
evaluate and report on trees located at 10231 Mira Vista Road, Cupertino,
Calif. This report is intended to provide evidence of compliance for
ordinance No. 1799 of the City Council of the City of Cupertino (privacy
protection requirements) Pictures provided correspond with site map (See
"Exhibit A"). The following is our findings and recommendations.
Method of Evaluation
1. Record location of each tree on site map.
2. Identity each tree as to species.
3. Measure trunk diameter at point 48" above grade.
4. Evaluate tree health of the tree on a 0 - 5 scale, where 0 = poor
and 5 = excellent condition.
5. Note any areas of structural weakness such as decay, cracks, poor crown
conformation, history of failure, etc.
Description of Trees
A total of 3 trees were evaluated which includes the following:
Common Name Scientific Name No. of Trees
Live Oak Quercus agrifolia
Mulbury Mulbury
Cherry Plum Prunus cerasifera
10
TreeWorld
P.O. Box I I I I Santa Clara, CA 95052
408-984-8812
State Contractors lic #738961
Tree number ( 1 )
Type: live Oak
Trunk diameter at 4 ft. = 18"
Canopy diameter: = 30 ft.
Height: — 35 ft.
Health condition: 5
Save
Tree number ( 2 )
Type: Mulbury
Trunk diameter at 4 ft. = 10"
Canopy diameter = 10 ft.
Height: 15'
Health condition: 5
Save
Tree(3)
Type: Flowering Plum
Trunk diameter at 4 ft. = 5"
Canopy diameter = 7 ft.
Height: = 12 ft.
Health condition: 5
Save
O TreeWorld 0
P.O. Box I I I I Santa Clara, CA 95052
408-984-8812
State Contractors lic #738961
Summary
It is the opinion of this arborist that the trees planted and described and evaluated in this
report fully comply with the ordinance No. 1799 of the City of Cupertino. It is also
recommended that no further plantings be required in this area as long as regular
maintenance and yearly health inspection are made by a certified arborist.
The information contained in this report is true and correct to the best of my knowledge.
Changes to the plans and to the site may necessitate the revision to the information
contained herein.
TreeWorld
Ken R. Sanford
Arborist #ISA-2243
ri i
tayj I i ��n j .-•��j
I
1 i � It I „•
le, QueYw, Oak
reef ' I�on�S Nlalber� � ' -
\ ( (21 ZO
1 iz L' PrUndi shylCcvla
I
LZ
71.
29
�, N � I ..'• ' � . `a'�l'�.�c_ ^ate
Ordinance No. 1799
Appendix B
Release of Privacv Protection Measures
Single Family Residential Ordinance
Pale 6
Ordinance 19.28 (Single Family) requires that after September 21, 1998, all new two
story additions or homes be required to complete privacy protection measures. A
modification or deletion to these requirements may be granted by staff if the adjacent
affected property owners sign a release agreeing to modify or delete the requirements.
Date
Property Location
Address: 10231 Mira Vista Road, Cupertino, CA 95014
I agree to waive or modify the privacy protection measures required of the Single Family
Residential Ordinance as follows:
I agree to waive the Planting Requirements (Ordinance No. 1799 F.1).
Property Owner: j(
Address: �� •��
Phone: �P. ���r. ✓
Signature: k✓
Ordinance No. 1799 Paf,e 6
Appendix B
Release of Privacv Protection Measures
Single Family Residential Ordinance
Ordinance 19.28 (Single Family) requires that after September 21, 1998, all new two
story additions or homes be required to complete privacy protection measures. A
modification or deletion to these requirements may be granted by staff if the adjacent
affected property owners sign a release agreeing to modify or delete the requirements.
Date
Property Location
Address: 10231 Mira Vista Road, Cupertino, CA 95014
I agree to waive or modify the privacy protection measures required of the Single Family
Residential Ordinance as follows:
I agree to waive the Planting Requirements (Ordinance No. 1799 F.1).
Property Owner.
Address:
Phone: '4, rr
Signature: ,
`„ J
Ordinance No. 1799
Appendix B
Release of Privacy Protection Measures
Single Familv Residential Ordinance
Page 6
Ordinance 19.28 (Single Family) requires that after September 21, 1998, all new two
story additions or homes be required to complete privacy protection measures. A
modification or deletion to these requirements may be granted by staff if the adjacent
affected property owners sign a release agreeing to modify or delete the requirements.
Date
Property Location
Address: 10231 Mira Vista Road, Cupertino, CA 95014
I agree to waive or modify the privacy protection measures required of the Single Family
Residential Ordinance as follows:
I agree to waive the Planting Requirements (Ordinance No. 1799 F.1).
Property Owner. - r'% - - /q /A/IS
Address: 1=11 MIR i4IWW— ,b
Phone:
Signature: