Loading...
05080261 (2)CITY OF CUPERTINO t BUILDING DIVISION PERMIT mCON7CR.CTt�R INF�ORM�.TTON�* 9[u Bu1LDINGADDRESS: 1 74 TATTRETTA DR ARGONAUT WINDOW & DOOR PERMIT N005O80261 NER'S NAME: PERMIT ISSUE DATE ROBERT WONG NE: SANITARY NO. CONTROL NO. 408)996-9670 CHITEC (ENGINEER: BUILDING PERMIT INFO BLDG ELECT PLUMB MMI LICENSED CONTRACTOR'S DECLARATION lob Description 1 hereby affirm that 1 am licensed ureter provisions of Chapter 9 (commencin{ with Section 7M)) tiolvislon 3 often Business and Prafessiom Code. and my license is inronrnrenand erroet(z_r % �Z2` 15 WINDOWS/2 DOORS/EGRESS License Cl0s{, Lic,p Dam�L''^SG-'J Contractor ARCHITECTS DECLARATION 1 undcramnd my plans shall be used as public recnNs Li.dacd Professional OWNER -BUILDER DECLARATION I hereby affirm that 1 am exempt from du Contractors License Law for the following mason. (Section 703 1.3, Business and Profesaiom Code: Any city ar county which requires a permit ,, Construct, ellen improve, dcmolit h. ar repar, any sora m $10000 prior to its issuance, also requires the applicant far such permit to File a signed statement Ft. Floor Area Valuation that he is licensed pursuant to the previsions of the Cantratori License Law (Chapter 9 Sq. (commencing with Section 700() or Division 3 of the Business and Professions Crxk) or - tat M is exempt therefrom and the basis for the alleged exemption. Any violation of rou Occupancy Type Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not mareNan five hundred dallan (5500)L q 1, as owner of the propery, or my employees with wages as their cele compensation, Required Inspections will do he work and the amcmum is not intended or.frenal forsalo(S.C. 70". Businw and Forrestal.. Code: The Conmun's License taw does not apply Ine an owner of 9 P property, who builds or improves thereon, end who does such work himself or through his Own employees, provided that such Improvements are not intended oroRaed (Or Silt. if. however, she building or improvement is sold within one year of completion, the owner builder will have the burden of proving that he did not build or improve for purpose of sale.). ❑ I. as owner of the property, am exclusively contracting with li¢nsed convector, to cense the (Sec. aq Business am Professions Cadet) Them to thencor's nd La es no, an owner of brittle or imporum thereon, and came law coca not apply / tpropertyctowha who canvas. for such projects with a conrrecror(a) licensed pursuant te the Contractors a D LicenseLOW. C]1 am exempt antler Sec. . B & P C for this mason p� der Date V� WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ham and will maintain a Cenifrme, of Cement. self-intim for Workers Compere as provided for by Section 3700 of the Labor Cotle, for she performance of the for which this Permit is issued. 01 I have end will maintain Worker's Compensation Insurance, as required by Section 3700 Crude, labor Code, for the pcRormma of the work for which this permit is issued. ' My Workers Cmepematlon Insurance earn., and Pali, number am: 57 -%k'(F fdNiJ Q a6 21 L4 '� ¢.oder. Policy No.: CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE Obls motion reed tat hccomplcwd Blue permit is forome hundred dallars (SIM) or lmcJ 1 certify that in the Performance or Nc work for which this Permit Is issued, I shall not employ any person in any manner. as to became subjecu0 the Workers' Campleccomn Law. Of Calif, a q Applicen NOTICE APPLICA r making Ws of Exemption, you should bee a subject to the Worker's Compemmion previsions of the Labor Code, you must o .,wi th comply with such provisions or this permit shall W deemed revoked. 'me CONSTRUCTION LENDING AGENCY I hereby affirm that there Is a Construction lending agency for the perro mance of the work for which this permit is issued (See. 3097, Civ. C.) Ispders Name Lender's Address and sure that the above iws rmuiun is { 1 cenify the I have read this city building 1 agree to and county comply with ill city and county and sum laws relating e ntdinancm c ection P rposesenlatives of this City reenter Upon Ne i0mvengeolumcd construction. red hereby for I shove-(Weiagree to awrty indcor.cdan keephe. (We) agree o cave, indemnity and keep hay in an the City of against against I which movie anyway accuse against mid City /n l i, f/'U� incoides,judgmenu,crauandexpensu ineonsCANT ND gmmi NDSAspc it s APPLICANT UND RS NDS A ILL COM Y WITH ALL NON -POINT J Issued by: Date SOURCEREG TIO g 4 ° w Re -roofs ignat oral ica Con D Dem AZARDOUS MATERIALS DISCLOSURE Type of Roof Will Nee cant or furore building aeupmtstore orhandle hazardous material m defined by the Cupenino Municipal Code. Chapter 9.13, and Ne Health and Safety oJc. Scotian 35533(a)7t All roofs shall be inspected prior to any roofing material being installed. ❑ 6Ma If a roof is installed without firs[ obtaining an inspection, I agree to remove Willll the applicant or future building Occupant Six equipment or dcvi¢s which It havardom air contaminants as JcOncd by the Bay Area Air Quality Management all new materials for inspection. ❑ Yes Y - I have mad the horardttus mmcdals requirements under CWptcr6.95oftW Califor.QS� ria HCnlh A Safety Cmlc, Secllans 25X15,35533 and 25576.1 undersand that if the huilJm ( '—.d N/ Jam not currently have a a nr, that itis responsibility . dairy the acupant of the myuiomcncv which t etpri.mi adca orac.r�tcamaroccapan,, i re A lican Date 30 —05 All roof coverings to be Class "B" or better weer thnri a t Dam CITY OF CUPERTINO PERMIT APPLICATION FORM APN # 3.2 6 S oza Date: g -3a --as Building Address: Mailing Address (if different from building address): 01ZI/ Ljv2r Ae, Owner's Name: . W O,A s ne #: `. _ W Contractor: P,&.W-,q Nc. License #: GQ _72-3 Contact: t Phone: 8. 6`4 9. Tr � ILF-P lytel*-K4� Fax: -.374-ro q Cupertino Business License#: Building Permit Info: BldgyJ, Elect ❑ Plumb ❑ Mech ❑ Job Description: ININU- s \µ #4&#WS 2 ea LIKE 0PiWIA1 y g Residential wNEerPV C -4d &m mercial ❑ ' Sq.Ft. Floor Area: Sq.Ft.: Cost of Project: 6a ' ov /O, o Occupancy Group: Type of Construction: Please check this box if the project is a second -story addition: ❑ Project Size: Standard ❑ Laze ❑ Major ❑ BBOILER5 Quantity Fee ID Fee Description Fee Group BAPPLOTHER Other Appliances MECHANICAL BBOILERI Boiler <= 100,000 Btu MECHANICAL BBOILER2 Boiler > 100K to 500K Btu MECHANICAL BBOILER3 Boiler> 500K to 1M Btu MECHANICAL BBOILER4 Boiler> 1M'to 1.75 M Btu MECHANICAL BBOILER5 Boiler > 1.75M Btu MECHANICAL BCONSTAX Construction Tax BUILDING BCONSTAX Ind/Off/Comm/Quasi BUILDING BCONSTAXBQ Con. Tax for BQ Zone BUILDING BCONSTAXH Hotel and Motel BUILDING BCONSTAXR Constax — Resi/Mobile BUILDING BELEC1000 Elec 600V <= 1000A ELECTRICAL BELEC1001 Elec 600V > 1000A ELECTRICAL BELEC200 Elec Svcs 600V <= 200A ELECTRICAL BENERGY Energy BUILDING BENERGYADD Energy Add Multi BUILDING BINVESTIGA Investigation fee BUILDING 1of3 � ���, 7i� 10 CUPERTINO CITY OF CUPERTINO PERMIT APPLICATION FORM Quantity Fee ID Fee Description Fee Group BMISCELL Miscellaneous Fee BUILDING BMITIGATC Comm. Housing Mit. Fee BUILDING BNUCOMME New Comm Electric ELECTRICAL BNUCOMMM New Comm Mechanical MECHANICAL BNUCOMMP New Comm Plumb PLUMBING BOVERTIME Inspection Overtime BUILDING BPBACKFLOW Atmospheric Vacuum PLUMBING BPCESSPOOL Cesspool PLUMBING BPERMFEE Bldg Permit Fees BUILDING BPFIXTURE Pb1g Fixture PLUMBING BPGAS Gas Piping System Fee PLUMBING BPINTERCEP Ind Waste Interceptor PLUMBING BPLANCHK Plan Check Fee BUILDING BPLANCKADD Plan Check Add Multi BUILDING BPLANCKREP Plan Check Repeat Fee BUILDING BPREPIPE Re i e Of Fixtures PLUMBING BPSEWAGE Sewage Disposal PLUMBING BPSEWER Sewers PLUMBING BPSPRINK Lawn S rinklerBackflo PLUMBING BPSTORM Storm/Rain Water PLUMBING BPTRAP Kitchen Trap PLUMBING BPVENT Alt of Drain & Vent PLUMBING BPWATER IustaWAlter Water Pie PLUMBING 'BPWHEATER Water Heater/Vent PLUMBING BPWSVCS Main Water Service PLUMBING BREINSPECT Reinspection Fee BUILDING BREMACOVER A/C Unit > 10,000 cfm MECHANICAL BREMAIRHAN A/C Units <= 10,000 cfm MECHANICAL BREMAPPLI Appliance Install MECHANICAL BREMBUSWAY Remodel Busways ELECTRICAL BREMFIXT Lighting Fixtures ELECTRICAL BREMFURN Relocation of Furnace MECHANICAL BREMFURNOV Relo Furnace > I OK btu MECHANICAL BREMHEAT Heater Installation MECHANICAL BREMINHOOD Installation of Hood MECHANICAL BREMMISC Misc Apparatus ELECTRICAL BREMNRAPP Rem Non -Res Appliance ELECTRICAL BREMPOLE Pole/Platform Fixture ELECTRICAL BREMPOWER Power Device/Apparatus ELECTRICAL BREMRECEPT Rc tl Switch & Outlets ELECTRICAL BREMRELOCA Relocation of Hood MECHANICAL BRENMPALT Repair/Alter Heating MECHANICAL BREMRESAPP Remodel Res Appliance ELECTRICAL 2 of 3 OF CUPEIINO CITY OF CUPERTINO PERMIT APPLICATION FORM Quantity Fee ID Fee Description Fee Group BREMSIGNAD Rmdl Signs Add Branch ELECTRICAL BREMSIGNS Remodel Signs, Marquee ELECTRICAL BREMTHEATR Theatrical Lighting Fix ELECTRICAL BREMVENFAN Vent Fan Single Duct MECHANICAL BREMVENSYS Ventilation Systems MECHANICAL BSCBLVD Scb Specific Plan BUILDING BSEISMICOM Seismic Commercial BUILDING BSEISMICRE Seismic Fee Res BUILDING BSPECIAL Special Inspection BUILDING ' BSWIM Swimming Pool BUILDING BTEMP Temporary Power ELECTRICAL BTEMPPERM Temporary Bldg Permit BUILDING - BTEMPSVCS Temp Dist Svcs ELECTRICAL BUSLIC Business License BUILDING ELECTRIC Electrical sq foot ELECTRICAL EPERMITFEE Elec Permit Issuance ELECTRICAL MPERMFEE Mechanicals . foot MECHANICAL MPERNUTFEE Mech Permit Issuance MECHANICAL PPERMITFEE Plumbing Permit Issue PLUMBING PPLBG Plumbing Fee sq foot PLUMBING PLLONGRNGC Planning LR Comme/ Multi -Pam PLANNING PLLONGRNGR Planning Long Range Residential PLANNING ZADDCHG Address Chane BUILDING 3 of 3 1 J I N � O A T v 00 3 N T O D\ m 9 � � tai, G rte. O n x� � � v .•_» oo O m w O 3 X n a � w z N 6 z 1p azo0 a �< m > ^ w w rpm N "O x C 3 = [n c,s wr m C A xo x ti oo ti .�. 00 m G W CD N dQ rT z v � x R O ' p N z n N 3 W O r Z � v y a� e 0 z r w o z B < � g a o 3 0 3 2 0 a G= y O G a O H NTly I N � O A T v 00 3 N T O D\ m 9 � � tai, G m w O 3 n a z z azo0 a m > ^ w D 3 = [n A m C A oo ti .�. 00 G W CD N dQ rT z o x rn p N z n 3 O � n 0 z z B < Code Corner Emergency Escape and Rescue Openings p IRC R310 Ln 0 N by Ron Dayville o Senior Plans Examiner, City of EI Segundo, California; rondarvilleOaol.co co U LD IE -2o" clear-�{ a Maximum size window for 20" clear width. �- 34 1/a' Clow -� Openable v Minimum ;i Area size window v 5.7 sq. ft for 24- a clear height 44" sill height Because so many fire deaths occur when occupants of residential buildings are asleep at the time of a fire, the International Residential Code' (IRC) requires that: • basements with habitable space and • every sleeping room below the fourth story shall have at least one operable.window or exterior door opening approved for emergency escape and rescue. IRC Section R310.1.4 requires rescue openings to be operational from the inside of the room without the use of keys or tools, and Section R303.5 requires that glazed openings open directly onto a street or public alley, or a yard or court located on the same lot as the building. • The net clear openable area shall be no less than 5.7 square feet (see exceptions for grade floor openings and window wells). • In addition to the above requirement, the net clear openable height dimension shall be a minimum of 24 inches. The net clear openable width dimension shall be a minimum of 20 inches. (Note: using both minimum figures will not obtain the required 5.7 square feet.) • The finished sill height shall not be more than 44 Inches above the floor. The chart below summarizes the minimum window dimensions that will achieve a 5.7 square -foot opening. Minimum Wldth/Height Requirements for Emergency Eacape and Rescue Windows finehasl Width 20 1 20.5 21 21.5 1 22 1 22.5 1 23 1 23.5 1 24 1 24.5 1 25 1 25.5 1 26 26.5 1 27 Height 41 40 39.1 38.2 37.3 38.5 35.7 34.9 34.2 33.5 32.6 322 31.6 31 30.4 Width 27.5 28 28.5 29 29.5 1 30 1 30.5 1 31 1 31.5 1 32 32.5 1 33 1 33.5 34 34.2 Height 29.8 1 29.3 28.8 28.3 27.8 27.4 26.9 26.5 2fi.1 25.7 25.3 24.9 1 24.5 24.1 24 i C. M 310.0.2 310.14.2 kler systems and standpipes shall be designed and installed as specified in Chapter 9. 310.10 Fire Alarm Systems. Group R, Division 1 Occupancies shall be provided with a manual and automatic fire alarm system in apartment houses three or more stories in height or containing 16 or more dwelling units, in hotels three or more stories in height or containing 20 or more guest rooms and in congregate resi- dences three or more stories in height or having an occupant load of 20 or more ffor SFMJ in accordance with Chapter 35 and the California Fire Code. A fire alarm and communication system shall be provided in Group R, Division l Occupancies located in a high-rise building. EXCEPTIONS: 1. A manual fire alarm system need not be pro- vided in buildings not over two stories in height when all individual dwelling units and contiguous anic and crawl spaces are separated from each other and public or common area by at least one-hour fin -resistive occupancy separations and each individual dwelling unit or guest room has an exit directly to a public way, exit court or yard. 2. A separate fire alarm system need not be provided in buildings that arc protected throughout by an approved supervised fire sprinkler system having a local alarm to notify all occupants. 2a. [For SFMJ A separate manual and automatic fire alarm sys- tem need not be provided in buildings that am protected throughout by an approved supervised fue sprinkler system having a local alarm sys. tem forthe notificationofalloccupams. Occupant notifcadonshall re- sult from actuation ofany flowofwaterorthe operation of anymanual station. The alarm signal shall be a distinctive sound that is not used for any other purpose other than the fire alarm. Alarm -signaling de- vices shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by 15 decibels minimum, or ex- ceeds any maximum sound level with a duration of 30 seconds minimum by 5 decibels minimum, whichever is louder. Sound levels for alarm signals shall be 120 decibels maximum. For the purposes of this section, area separation walls shall not define separate buildings. 310.10.1 [For SFMJ Group R, Divisions 2.1 or 2.3 Occupan- cies. Buildings containing Group R, Division 2.1 Occupancy shall be provided with an approved manual and automatic fire alarm system in accordance with Chapters 3,-9 and 35 and the California Fire Code. EXCEPTTON: Buildings housing nonambulatory clients on the first story only, and which oreprotected throughout by the following: 1. Anapprovedandsupervisedautomoticsprudrlersystem,asspe- cified in Chapter 9, which upon activation will initiate the fin alarm system to notify all occupants. 2. A manual fire alarm system in accordance with Chapters 9 and 35. 3. Smoke alarms required by Section 310.9.1. 310.10.2 [For SFMJ Group R, Divisions 1.1.1,1.2.1 and 1.3.1 Occupancies. In addition tosmoke detectors required bySection 310.9, Group R, Divisions 2.1.1, 2.2.1 and 2.3.1 Occupancies shall be provided with at least one manual pull station at a loca- tion approved by the authority having jurisdiction Such pull sta- tion shall actuate a distinctive fire alarm signal which shall be audible throughout the facility. These devices need not be inter- connected to any other firealarm device, electrically supervised orprovided with emergency power. ' 310.10.3 [For SFMJ Group R, Division 2.2 Occupancies. In addition to smoke alarms required by Section 310.9, buildings containing Group R, Division 2.2 Occupancies shall be provided _ with a manual fire alarm system in accordance with Chapter 35 and the California Fire Code. —---NOTF: See Health and Safety Code, Sections 13113.7and 13113.8" for other fire alarm requirements. 1-34 .. 2001 CALIFORNIA BUILDING 310.12 Special Hazards. Chimneys and heating apparatus shall conform to the requirements of Chapter3l and the Mechani- cal Code. The storage, use and handling of flammable and combustible liquids in [for SFMJ Divisions 1 and 2 Occupancies shall be in accordance with the Fire Code. In Division I Occupancies, doors leading into rooms in which Class I flammable liquids are stored or used shall be protected by a fire assembly having a one-hour fire -protection rating. Such fire assembly shall be self-closing and shall be posted with a sign on each side of the door in 1 -inch (25.4 mm) block letters stating: FIRE DOOR—KEEP CLOSED. [For SFMJ Every unenclosed gas-fired water heater or fur- nace which is within the area used for child care in a large family day-care home shall be protected in such a way as to prevent chil- dren from making contact with those appliances. EXCEPTION: This does not apply to kitchen stoves or ovens. 310.13 Access to Buildings and Facilities. 310.13.1 [For DSA/ACJ General accessibility requirements can be found in Chapters 10, 11A, 11B, 11C and 30. 310.14 [For HCD 1, SFMJ Existing Group R, Division 1Oc- cupancies. In accordance with Health and Safety Code Section 13143.2, the provisions of Sections 310.14.3 through 310.14.11 shall only apply to multistory structures existing on January 1, 1975, let for human habitation, including, and limited to, apart- ments, houses, hotels and motels in which rooms used for sleep- ing are let above the ground floor. EXCEP77ON(ForHCD I]: Any portion of an existing residential structure may be altered, repaired or rehabilitated regardless of the value ofihe workortheduration ofthecomiructionperiod withoutthe entire structure being made to comply with the mquimmems of this chapter for new construction NOTES [For HCD 1]: 1. See Sections 17958.8 and 17958.9 of the Health and Safety Code for regulations governing the alteration and repair of existing and relocated buildings. 2. See Section 179203 of the Health and Safety Code for condi- tions that constitute a substandard building. 310.14.1 [For HCD 11 Limited -density owner -built rural dwellings. The provisions regulating the erection and construc- tion of dwellings and appurtenant structures shall not apply to existing structures as to which construction is commenced or approvedprior to the effective date of these regulations. Require- ments relating to use, maintenance and occupancy shall apply to all dwellings and appurtenant structures approved for construc- tion or. constructed before or after the effective date of this chapter. - - 310.14.2 [For SFMJ Number of exits. Every apartment and every other sleeping room shall have access to nor less than two exits—when the occupant load is JO or more (exits need not be directly from the apartment or sleeping room). A fire escape as specified herein may be used as one required exit. Subject to approval of the authority having jurisdiction, a ladder device as specified herein may be used in lieu of a fire es - C L A L • to 0 N 310.11 Heating. Dwelling units, guest rooms and tong ~e residences shall be provided with heating facilities caps. f maintaining a room temperature of 70°F (21eC) at a point t cD (914 mm) above the floor in all habitable rooms. F.XCEPTION[ForHCD I]: For limted-density owner-bui al dwellings, a heating facility or appliance shall be insmlkd ch A dwelling subject to theprovisionsofSubchapter 1. Chapter 1, c California Code of Regulations; however, there shall be no specified C requirementforheatingcapaciyor tempersturemainterrance. The use C of solid fuel or solar -heating devices shall be deemed as complying C with the requirements of this section If nonmmwnbk fuel is used in A these dwellings, rooms so heated shall meet current installation stan- c dards. C 310.12 Special Hazards. Chimneys and heating apparatus shall conform to the requirements of Chapter3l and the Mechani- cal Code. The storage, use and handling of flammable and combustible liquids in [for SFMJ Divisions 1 and 2 Occupancies shall be in accordance with the Fire Code. In Division I Occupancies, doors leading into rooms in which Class I flammable liquids are stored or used shall be protected by a fire assembly having a one-hour fire -protection rating. Such fire assembly shall be self-closing and shall be posted with a sign on each side of the door in 1 -inch (25.4 mm) block letters stating: FIRE DOOR—KEEP CLOSED. [For SFMJ Every unenclosed gas-fired water heater or fur- nace which is within the area used for child care in a large family day-care home shall be protected in such a way as to prevent chil- dren from making contact with those appliances. EXCEPTION: This does not apply to kitchen stoves or ovens. 310.13 Access to Buildings and Facilities. 310.13.1 [For DSA/ACJ General accessibility requirements can be found in Chapters 10, 11A, 11B, 11C and 30. 310.14 [For HCD 1, SFMJ Existing Group R, Division 1Oc- cupancies. In accordance with Health and Safety Code Section 13143.2, the provisions of Sections 310.14.3 through 310.14.11 shall only apply to multistory structures existing on January 1, 1975, let for human habitation, including, and limited to, apart- ments, houses, hotels and motels in which rooms used for sleep- ing are let above the ground floor. EXCEP77ON(ForHCD I]: Any portion of an existing residential structure may be altered, repaired or rehabilitated regardless of the value ofihe workortheduration ofthecomiructionperiod withoutthe entire structure being made to comply with the mquimmems of this chapter for new construction NOTES [For HCD 1]: 1. See Sections 17958.8 and 17958.9 of the Health and Safety Code for regulations governing the alteration and repair of existing and relocated buildings. 2. See Section 179203 of the Health and Safety Code for condi- tions that constitute a substandard building. 310.14.1 [For HCD 11 Limited -density owner -built rural dwellings. The provisions regulating the erection and construc- tion of dwellings and appurtenant structures shall not apply to existing structures as to which construction is commenced or approvedprior to the effective date of these regulations. Require- ments relating to use, maintenance and occupancy shall apply to all dwellings and appurtenant structures approved for construc- tion or. constructed before or after the effective date of this chapter. - - 310.14.2 [For SFMJ Number of exits. Every apartment and every other sleeping room shall have access to nor less than two exits—when the occupant load is JO or more (exits need not be directly from the apartment or sleeping room). A fire escape as specified herein may be used as one required exit. Subject to approval of the authority having jurisdiction, a ladder device as specified herein may be used in lieu of a fire es - C L A L • L A •A IILA • r, L_J L A LC 2001 CALIFORNIA BUILDING CODE vided there is adequate light and ventilation and adequate means of egress. 310.7 [For HCD ]]Efficiency Dwelling Units. An efficiency dwelling unit shall conform to the requirements of the code ex- cept as herein provided or as provided in Health and Safety Code Section 17958.1.: 1. The unit shall have a living room of not less than 220 square feet (20.4 m2) of superficial floor area. An additional 100 square feet (9.3 m2) of superficial floor area shall be provided for each occupant of such unit in excess of two. 2. The unit shall be provided with a separate closet. 3. The unit shall be provided with a kitchen sink, cooking appliance and refrigeration facilities, each having a clear working space of not less than 30 inches (762 mm) in front. Light and ven- tilation conforming to this code shall be provided. 4. The unit shall be provided with a separate bathroom contain- ing a water closet, lavatory and bathtub or shower. NOTE: Subjectio otherprovisionsof larq the applicablesubseetion ofthellealth and Safety Code is repeated herefor clarity and reads as follows: Section 17958.1. Subject to Sections 17922, 17958 and 17958.5, a city or county may, by ordinance, permit efficiency units for occupancy by no more than two persons which have a minimum floor area of 150 square feet and which may also have partial kitchen or bathroom facilities, as specified by the ordi- nance. In all other respects, these efficiency units shall conform to minimum standards far those occupancies otherwise made ap- plicable pursuant to this part. "Efficiency uni4 "as used in this section, has the samemeaning specified in the Uniform Building Code of the International Con- ference of Building Officials, as incorporated by reference in Chapter 2-12 of Part 2 of Title 24 of the California Code ofRegu- lotions. 310.8 Shaft and Exit Enclosures. Exits shall be enclosed as specified in Chapter 10. Elevator shafts, vent shafts, dumbwaiter shafts, clothes chutes and other vertical openings shall be enclosed and the enclosure shall be as specified in Section 711. In nonsprinklered Group R, Division 1 Occupancies, corridors serving an occupant load of 10 or more shall be separated from corridors and other areas on adjacent floors by not less than ap- proved fixed wired glass set in steel frames or by 20 -minute smoke- and draft -control assemblies, which are automatic clos- ing by smoke detection. A310.9 Smoke Alarms and Sprinkler Systems. C 310.9.1 Smoke Alarms. 310.9.1.1 General. Dwelling units, congregate residences and L A hotel or lodging house guest rooms ffor SFMJ and residential L c care facilities classified as Group R, Divisions 2.1.1, 2.2.1, 2.3.1 L c and Group R, Division 6 Occupancies that are used for sleeping L c purposes shall be provided with smoke alarms or multiple -station L c smoke alarms. Smoke alarms shall be installed in accordance L c with this code and the approved manufacturer's instructions. L A EXCEP770N: A fire alarm system with smoke detectors located in accordance with Sections 310.9.1.4 and 310.9.1.5 may be installed in L A lieu ofsmoke alarms. Upon actuation ofthe detector,only those notift- LA cation appliances in the dwelling unit or guest room shall activate. 310.9.1.2 Additions, alterations or repairs to Group R Occu- pancies. When the valuation of an addition, alteration or repair to a Group R Occupancy exceeds $1,000 and a permit is required, or when one or more sleeping rooms are added or created in exist - 310.6.3 310.9.2 ing Group R Occupancies, smoke alarms shall be installed in ac- A II cordance with Sections 310.9.1.3, 310.9.1.4 and 310.9.1.5 of this section. EXCEPTION: Repairs to the exterior surfaces of a Group R Occu- pancy arc exempt from the requirements of this section. 310.9.1.3 Power source. In new construction, required smoke alarms shall receive their primary power from the building wiring when such wiring is served from acommercial source and shall be equipped with a battery backup. The smoke alarm shall emit a sig- nal when the batteries are low. Wiring shall be permanent and without a disconnecting switch other than those required for over - current protection. Smoke alarms may be solely battery operated when installed in existing buildings; or in buildings without com- mercial power; or in buildings which undergo alterations, repairs or additions regulated by Section 310.9.1.2. 310.9.1.4 Location within dwelling units. In dwelling units, a smoke alarm shall be installed in each sleeping room and at a point centrally located in the corridor or area giving access to each separate sleeping area. When the dwelling unit has more than one story and in dwellings with basements, asmoke alarm shall be in- stalled on each story and in the basement. In dwelling units where a story or basement is split into two or more levels, the smoke alarm shall be installed on the upper level, except that when the lower level contains a sleeping area, a smoke alarm shall be in- stalled on each level. When sleeping rooms are on an upper level, the smoke alarms shall be placed at the ceiling of the upper level in close proximity to the stairway. In dwelling units where the ceiling height of a room open to the hallway serving the bedrooms exceeds that of the hallway by 24 inches (610 mm) or more, smoke alarms shall be installed in the hallway and in the adjacent room. Smoke alarms shall sound an alarm audible in all sleeping areas of the dwelling unit in which they are located. 310.9.1.5 Location in efficiency dwelling units, congregate residences and hotels. In efficiency dwelling units, hotel suites and in hotel (for SFMJ motel or lodging house and congregate residence and residential care and group care facility sleeping rooms, smoke alarms shall be located on the ceiling or wall of the main room or each sleeping room. When sleeping rooms within an efficiency dwelling unit or hotel suite are on an upper level, the smoke alarms shall be placed at the ceiling of the upper level in close proximity to the stairway. When actuated, the smoke alarms shall sound an alarm audible within the sleeping area of the dwell- ing unit or congregate residence, hotel suite, or sleeping room in which it is located. 3109.1.6. Single-andmultiple-station smoke alarms andsmoke detectors installed within dwelling units, congregate residences and hotel rooms shall not be connected to the building fire alarm system. EXCEPTION: Connection of such devices for annunciation only. Buildings containing Roup R, Division 2.1 Occupancies shall be provided with an approved manual and automatic fire alarm system in accordance with Chapters 3, 9 and 35 and the Califor- nia Fire Code. EXCEPTION: Buildings housing nonambulatory clients on the first story only, and which are protected throughout by the following: 1. Anapprovedandsupemisedautomaticsprintlersystem,asspe- cified in Chapter 9, which upon activation will initiate the fire alarm system to notify all occupants. 2. A manual fire alarm system in accordance with Chapters 9 and 35. 3. Smoke alarms required by Section 310.9.1. 310.9.2 Sprinkler and standpipe systems. When required by Section 904.2.1 or other provisions of this code, automatic sprin- 1-33 All LII LII 0 0 0 )£ - ;j § ■ ) .'o { \ � � 23 0 ;0 0 0 � 1p ; Jim� §( )£ - ;j § ■ ) .'o { \ � � 23 0 ;0 0 0 �