Loading...
RM-2025-010 - A1 Site Plan1021 NOVEMBER DR. PROPOSED NEW ADDITION 173 SQ. FT. 10 5 . 6 9 ' 82.21' 48' 10 0 ' (E) WATER METER TO REMAIN SIDEWALK PLANTER STRIP GP RE S I D E N T I A L DE S I G N S 82 9 S . 7 t h S t r e e t S a n J o s e , C A 9 5 1 1 2 Ph o n e : ( 4 0 8 ) 2 9 2 - 3 8 0 0 ( 4 0 8 ) 2 7 4 - 3 0 6 9 gp r e s i d e n t i a l @ g m a i l . c o m OW N E R : Job Drawn Scale Date Sheet A NE W A D D I T I O N PR O P O S E D 7.19.24 AS NOTED GP CU P E R T I N O , C A 9 5 0 1 4 10 2 1 N O V E M B E R D R I V E SH A H R E S I D E N C E 1 SHAN RESIDENCE PROPOSED ADDITION & REMODEL 1021 NOVEMBER DR. CUPERTINO, CA 95014 a.p.n # ....................... 362-16-001 occupancy group .......... r-3/u construction type ........ v-b zoning ........................ r1-6 california building code (cbc)..........2022 california electrical code (cec).......2022 california mechanical code (cmc)..... 2022 california plumbing code (cpc).........2022 california energy code ..................2022 california fire code (cfc)................2022 california residential code (crc)......2022 city of cupertino municipal code 2022 california green building code GENERAL NOTES APPLICABLE CODES PROJECT DATA SCOPE OF WORK a) lot size ...................... 6,510 sq. ft. b) existing dwelling .......... 2,076 sq. ft. c) existing garage ............ 445 sq. ft. c.1) reserve garage area....... 35 sq, ft. d) existing front porch ......... 34 sq. ft. e) new addition .................. 173 sq. ft. f) 12" eaves ...................... 215 sq. ft. SITE AREA 5) 4) 3) 2) 1)termination of all environmental air ducts shall be a minimum of 3ft from any openings in the building (i.e., dryers, bath, and utility fans, etc. must be 3ft away from doors, windows, opening skylights or attic vents.) water closets shall have a maximum of 1.28 gallons per flush. per cpc 402.2.2 seismic anchorage of water heater to include anchors or straps at points within the upper and lower one-third of its vertical dimension. the lower anchor located to maintain a minimum distance of 4 inches above. water heater pressure relief valve shall drain to an exterior wall per 2, cpc 608 tub/shower combination shall be provided with individual control valves of the pressure balance for the thermostatic mixing valve type per cpc 418. MECHANICAL-PLUMBING-ELECTRICAL NOTES shower/tub walls backing material shall be cementitious, wonderboard or durock. extened to a minimum height of 72 inches above the drain inlet per crc r308.4 (no green board allowed in shower/tub walls.) 5) 4) 3) 2) 1)emergency egress from sleeping rooms, min. 24" clear height, 20" clear width, 5.7 min. area opening height dimension shall be 44" max.above finish floor and egress windows for bedrooms shall be openable. provide smoke detectors in each existing sleeping area and at a central point in hallway solely battery. all smoke detectors in new construction area shall have primary power and equipped with battery back-up. per R308.3 & 308.4, glazing in hazardous locations shall be tempered. please see sheet a2 for addition notes on glazing in hazardous location. 6)any deviations from the plans, which are necessitated by the field conditions or any conditions from those indicated on plan, shall be called to the attention of the designer prior to continuing construction. all work is to be coordinated so the operation between the trades, where required, is accomplished. cross section proposed floor plan A3 foundation plan site plan A1.1 A1 DRAWING INDEX roof framing plan A2 existing & demo. floor plan T24 calgreen checklist title 24 all built-in appliances such as, stove, range hood, dish washer,garbage disposal, etc. shall have a dedicated circuit. 7) 6)shower head shall a max. flow of 1.8 gpm (upc 402.8) and kitchen faucets max. 1.8 gpm., lavatory faucet 1.2 gpm (upc 402.5) all branch circuits that supply 125 volt single-phase 15 and 20amp receptacle outlets installed in dwelling unit shall be protected by an arc-fault circuit interrupter(s). vicinity map SCALE: 1/8"= 1'-0" SITE PLAN (e) dwelling contractor shall verify all dimensions, elevations, foundation & framing systems, and conditions prior to starting construction. any deviations from approved plans which are necessitated by field conditions or conditions different from those indicated on plans must be brought to the attention of the design professional prior to starting construction so that a unanimous decision (among contractor, owner, design professional, and any other party involved) is made. otherwise, gp residential designs accepts no liability for any condition(s) caused by such deviations/discrepancies. GENERAL NOTES no concentrated flow across the right-of-way, nor neighboring properties. field verify site set-backs prior to excavation. for any discrepancies, please notify designer. NOTE: proposed rear addition of existing bedroom expansion 173 sq. ft. fire sprinkler - no total living sq. ft (b+e) = 2,249 sq. ft. f.a.r. (b+c+c.1+e) 2,729 / 6,510 = 41.9% lot coverage (b+c+c.1+d+e+f) 2,980 / 6,510 = 45.2% A5 T24-1 title 24 8) interior remodel of (n) kitchen 210 s.f. elevations (e) garage A4 5.2' A6 20'-0" rear setback provide 1-hour fire rated overhang - see detail 6.4' 5.0' T24-2 CG single-family residential mandatory requirement summary co m m e n t s 1 1 . 1 8 . 2 4 a p 1 PROJECT CONTACT designer: gp residential designs gpresidentialdesigns@gmail.com 408.292.3800 civil engineer: coppens land surveying christopher m. coppens 518-277-0097 owner: shah jitesh harish & deepa jagdish 1 certificate of installation notes: according to the 2022 energy code single-family residential compliance manual, a copy of the completed, signed, and dated cf2r must be posted at the building site for review by the enforcement agency in conjunction with requests for final inspection for the building. copies of the registered cf2r forms shall be provided to the homeowner. the certificate of installation (cf2r) is separated into: 1) envelope (cf2r-env), 2) lighting (cf2r-ltg), 3) mechanical (cf2r-mch), plumbing (cf2r-plb) 1 1 (e) outdoor condenser unit to be relocated 1 (n) location of (e) outdoor condenser unit 1 6'-1"3 10'-0" p.s.e. 5'-0" w.c.e. 1 1 20'-0" b.s.l. 5 5'-0" w.c.e. 5'-0" p.s.e. 1 1 2 new tankless gas water heater 1 (n) sun tunnel skylight 1 new sun tunnel in hallway 1 A1.2 notes 1 1 5'-0" setback 1 1 3 1 1'-0" eaves 1 (e) 6'-0" height wood fence 1 (e) 6'-0" height wood fence 1 (e) 6'-0" height wood fence 1 (e) driveway18'-0" 22.7'3 1 1 (e) conc. walkway 11 1 1 boundary and building location survey co m m e n t s 2 . 2 5 . 2 5 g p 2 3 co m m e n t s 3 . 1 8 . 2 5 g p 3 3 5 co m m e n t s 4 . 2 8 . 2 5 g p 4 LOT WIDTH = 54'-10" REQUIRED FRONT SETBACK = 20'-0" 54'-10" X 20'-0" = 1,096 S.F. (MINIMUM USEABLE REAR YARD AREA) USEABLE REAR YARD AREA CALCULATION 5 co m m e n t s 5 . 2 1 . 2 5 g p 5 16'-2" PROPOSED USEABLE REAR YARD AREA 1,290 S.F. 5 5 54'-10" 5 1,290 S.F. (PROPOSED USEABLE REAR YARD AREA) 1,290 S.F > 1,096 S.F. PROPOSED = OK