Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05. U-2006-05 Union Pacific RR
CITY OF CUPERTINO 10300 Torre Avenue, Cupertino, California 95014 DEPARTMENT OF COMMUNITY DEVELOPMENT REPORT FORM Application: Applicant (s): Property Owner: Property Location: U-2006-05, EXC-2006-03 Agenda Date: May 23, 2006 Jim Mattison (for AAT Communications Corp.) Union Pacific Railroad Approximately 600 feet southerly of McClellan Road along the Union Pacific Railroad corridor APPLICATION SUMMARY 1) Use permit to erect a telecommunication facility consisting of a 65-foot monopole (treepole) and ground equipment. 2) Height Exception for a 65-foot monopole (treepole) for a telecommunications facility to exceed 55 feet in height. RECOMMENDATION 1) Discuss the applications and continue them to a future public hearing to allow the applicant time to redesign the proposal to improve the visual screening, or 2) If the continuance is unacceptable to the applicant, deny the applications, per the . model resolution. PROJECT DATA General Plan Land Use Designation: Zoning: Existing Land Use: Maximum Height of Antennas: Distance to Nearest Residential Property: Required Setback to Residential: Environmental Determination: Transportation BQ- Quasi-Public Building Railroad right-of-way 65 feet 65+ feet 65 feet Categorical Exemption, Section 15303: New Construction or Conversion of Small Structures BACKGROUND: Project: The applicant, Jim Mattison, representing AAT Communications Corp., is proposing to construct a 110' long by 15' wide multi-user personal wireless service facility, consisting of a 65-foot tall treepole and a base equipment pad enclosed by an 8- foot tall chain link fence in the Union Pacific Railroad right-of-way (formerly Southern Pacific Transportation Company). The northerly end of the facility is located about 600 feet southerly of McClellan Road and would be accessed by an unimproved gravel access driveway from McClellan Road. A Santa Clara Valley Water District 15-foot 5-1 File No. U-2006-05, EXC-2006-03 Page 2 May 23, 2006 water pipeline easement parallels the proposed facility. The concrete pad and antenna base are outside of the easement area, but the chain link fence encroaches on the easement at grade and the antennas encroach on the easement 33 to 65 feet above grade. The proposed treepole that would carry the panel antennas is located on the southern side of the facility, easterly of a grove of Redwood trees located on Santa Clara Valley Water District property. The plan set shows a pole that could accommodate four racks of antennas, The facility is proposed for Cingular Wireless, which has a pending application to locate on the treepole if it is approved and built. The applicant believes other wireless communications carriers will be interested in the site and has shown an enlarged equipment pad to indicate its potential for at least four carriers. The surrounding land uses are: a two-story apartment complex to the east; single-family residential and the railroad corridor to the south; a Santa Clara Valley Water District groundwater recharge (pond) facility to the west; and light industrial uses and the railroad corridor to the north. Neighborhood Meetin~: The applicant hosted a neighborhood meeting on May 3, 2006 with noticing going out to a 1000-foot radius. Eleven residents attended the evening meeting. The residents had numerous questions about the project, including who organized the meeting and who the notices went to; the exact location of the proposed facility on the property and its distance from nearby residences; which carrier(s) were going to occupy the facility and how many; the safety of radio frequency radiation and how much would be cumulatively generated by the carrier(s); where existing wireless facilities were and who operated them; Attendees were provided with copies of the radio frequency radiation assessment, photosimulations, facility plans and location maps of existing facilities. DISCUSSION Location The proposed multi-user treepole is located about 710 feet southerly of McClellan Road. Based on the drawings showing hypothetical antenna arrangements, the lower antennas on the treepole are about 65 feet away from the property line of the 2-story apartment building on the east. The uppermost set of antenna should be mounted closer to the pole to achieve a residential setback at least equal to the height of the antennas. The aerial photograph below shows other measured distances to residential properties, all within the ordinance setback standards of 50 feet or the height of the antennas, whichever is greater. 5~;;' File No. U-2006-05, EXC-2006-03 Page 3 May 23, 2006 . Approximate Location of Treepole Visual Screening Base Equipment. As depicted the base equipment will be visible on the equipment pad. If the use permit application is approved, a condition should be added to the resolution requiring a vegetative green color opaque mesh to be mounted to the fencing in order to screen the base equipment. Treepole. The applicant is proposing a treepole like the one erected at 3860 Middlefield Road, Palo AIto, CA. Staff took several pictures of this treepole that are attached as Exhibit A. The applicant has provided three photosimulations to depict how the treepole would appear at the proposed location (Exhibit B). The vantage points selected are: 1) the intersection of McClellan Road and the UPRR corridor; 2) common area within the apartment complex; and 3) a west side trail next to the percolation pond on Water District property. 5/3 File No. U-2006-05, EXC-2006-03 Page 4 May 23, 2006 Because of the heavy onsite landscaping on the Water District property, the project site has very limited visibility from Bubb Road. As can be seen in the simulations, the treepole is visible in all three perspectives, although the existing trees in the foreground or background reduce the visibility of the pole. This is not considered satisfactory screening in accordance with the Siting and Design Guidelines of the City's Wireless Master Plan. Staff's preference is to shift the treepole southerly along the railroad corridor until the existing, tall redwoods act as an effective visual foreground or background to the treepole. This has been simulated by staff by shifting the treepole image in the applicant's photosimulations (Exhibit C) to demonstrate the additional level of screening that can be achieved. The applicant is open to this idea of shifting the treepole to a less visible vantage point, but lacked sufficient time to re-survey the site and modify the drawings before the hearing. The plans also depict additional landscape screening on the east side of the railroad corridor between the treepole and apartment complex. Staff is recommending the planting of 48" box coastal redwoods or other similar fast-growing, evergreen tree in the landscape gaps with needed irrigation until the trees have become established. Staff would also recommend additional large trees on the north and south sides of the project site at the edge of the railroad corridor to screen views from those directions. Staff recommends that the Planning Commission discuss the applications and continue it with directions to the applicant as to screening and location preference. Radio Frequency Radiation (RFR) Assessment A cumulative RFR assessment was prepared by Hammett & Edison, Inc. (Exhibit D ) based on a hypothetical antenna buildout of the treepole. A corrected Figure 3 is included with this report that was not available at the neighborhood meeting. In addition, an answer to a technical question asked at the neighborhood hearing is included in the back of the report. Based on the report assumptions, the maximum ground-level RF exposure due to multiple sets of antennas at different heights is estimated to be 0.021 mW f cm2 ,which is 2.5% of the applicable public exposure limit. The maximum calculated level at the second floor elevation of any nearby building is 3.4 % of the applicable exposure limit. Federal law prohibits local governments from making decisions on personal wireless service facilities based on RF considerations if the RF levels are below Federal 5,Lf File No. U-2006-05, EXC-2006-03 Page 5 May 23, 2006 Communications Commission safety standards. Since the type and number of antennas, the power output and mounting height may vary from this study, each company seeking to locate on this proposed treepole should prepare an individual RF study, taking into account project, approved and background RF levels. Staff recommends adding such a condition if this project is approved. Equipment Noise Although no base equipment has been proposed with this application, such equipment has the potential to generate noise in excess of City standards. A condition should be added to any use permit approval, requiring each carrier interested in locating on this monopole to provide a noise assessment of project and ambient noise with mitigations, if needed, to bring noise levels in conformance with the City noise ordinance. De AnzafUnion Pacific Trail The Land Usef Community Design Element of the General Plan envisions a regional trail along the Union Pacific Railroad corridor, extending from Cupertino all the way to Los Gatos. Acquisition of right-of-way or pedestrian easements is anticipated. As Union Pacific is consenting to a new land use and improvements to its property, not connected to its railroad transportation activities, staff recommends that any use permit approval be conditioned with a requirement to provide an improved trail from McClellan Road to Rainbow Drive with the granting of an easement for pedestrian and bicyclist public access. Submitted by: Colin Jung, Senior Planner Approved by: Steve Piasecki, Director of Community Developme~ ENCLOSURES Use Permit and Height Exception Model Resolutions of Denial Draft Use Permit and Height Exception Model Resolutions of Approval Exhibit A: Palo Alto Treepole pictures Exhibit B: 3 photosimuIations prepared by Previsualists Exhibit C: 2 modified photosimulations, showing treepole location shift Exhibit D: RFR Study prepared by Hammett & Edison, Inc. dated February 9, 2006 Plan Set G: \ Planning \ PDREPORT\ pcUsereports \ U-2006-05.doc 5'-5 Exhibit: A Palo Alto Treepole 3860 Middlefield Road 5~1o U-2006-0S CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 RESOLUTION NO. (denial) OF THE PLANNING COMMISSION OF THE CITY OF CUPERTINO DENYING A USE PERMIT TO ALLOW THE CONSTRUCTION OF A MULTI-USER PERSONAL WIRELESS SERVICE FACILITY CONSISTING OF A 65-FOOT TALL TREEPOLE AND ANCILLARY EQUIPMENT CABINETS LOCATED IN A FENCED ENCLOSURE 600 FEET SOUTIfERLY OF MCCLELLAN ROAD ALONG THE UNION PACIFIC RAILROAD CORRIDOR, APN 362-01-025 SECTION I: FINDINGS WHEREAS, the Planning Commission of the City of Cupertino received an application for a Use Permit, as described in Section II of this Resolution; and WHEREAS, the necessary public notices have been given in accordance with the Procedural Ordinance of the City of Cupertino, and the Planning Commission has held one or more public hearings on this matter; and WHEREAS, the project's treepole is inadequately screened and blended with natural landscaping in accordance with adopted siting and design guidelines and is considered visually obtrusive in its environmental context. The project is thus inconsistent with the City's Wireless Facilities Master Plan. NOW, THEREFORE, BE IT RESOLVED: That after careful consideration of maps, facts, exhibits, testimony and other evidence submitted in this matter, the application for Use Permit is not approved; and That the subconcIusions upon which the findings and conditions specified in this resolution are based and contained in the public hearing record concerning Application No. U-2006-05 as set forth in the Minutes of the Planning Commission Meeting of May 23, 2006 and are incorporated by reference as though fully set forth herein. SECTION II: PROTECT DESCRIPTION Application No.: Applicant: Property Owner: Location: U-2006-05 Jim Mattison (for AAT Communications Corp,) Union Pacific Railroad 600 feet southerly of McClellan Road along the Union Pacific Railroad corridor 6-7 PASSED AND ADOPTED this 23rd day of May 2006, at a Regular Meeting of the Planning Commission of the City of Cupertino, State of California, by the following roll call vote: AYES: NOES: ABSTAIN: ABSENT: COMMISSIONERS: COMMISSIONERS: COMMISSIONERS: COMMISSIONERS: ATTEST: APPROVED: Steve Piasecki Director of Community Development Marty Miller, Chair Cupertino Planning Commission g:/ planning/ pdIeport/ res/U-2006-05 denial. doc 513 EXC-2006-03 CITY OF CUPERTINO 10300 Torre Avenue . Cupertino, California 95014 RESOLUTION NO. (denial) OF THE PLANNING COMMISSION OF THE CITY OF CUPERTINO DENYING A HEIGHT EXCEPTION TO ALLOW A 65-FOOT TALL TREEPOLE AT A LOCATION APPROXIMATELY 600 FEET SOUTHERLY OF MCCLELLAN ROAD ALONG THE UNION PACIFIC RAILROAD CORRIDOR SECTION I: PROJECT DESCRIPTION Application No.: Applicant: Location: EXC-2006-03 Jim Mattison (for AAT Communications Corp.) about 600 feet southerly of McClellan Road along the Union Pacific Railroad corridor SECTION II: FINDINGS FOR EXCEPTION WHEREAS, in order to provide height flexibility in situations when collocation of personal wireless service antennas is desirable ITom a design and visual standpoint, an applicant for development may file an exception request to seek approval to deviate from the standards; and WHEREAS, the Planning Commission finds the following with regards to the Height Exception for this application: 1. That the siting and visual screening of the treepole are inadequate and create obtrusive visual impacts that are aggravated by the extra height of the treepole proposed under this height exception. 2. That the proposed project will be injurious to property or improvements in the area and be materially detrimental to the public welfare in that the treepole is inadequately screened in accordance with the siting and design guidelines of the City's Wireless Facilities Master Plan, and would degrade the visual environment ofthe area. 3. The proposed development will not create a hazardous condition for pedestrian or vehicular traffic because it is not sited within the travel ways or sight lines of pedestrian or vehicular traffic. NOW, THEREFORE, BE IT RESOLVED: That after careful consideration of maps, facts, exhibits, testimony and other evidence submitted in this matter, application no. EXC-2006-03 is hereby denied; and That the subconclusions upon which the findings and conditions specified in this Resolution are based and contained in the Public Hearing record concerning Application EXC-2006-03, as set forth in the Minutes of the Planning Commission Meeting of May 23,2006, and are incorporated by reference herein. 5 ß¡ Resolution No. Page 2 EXC-2006-03 May 23, 2006 PASSED AND ADOPTED this 23rd day of May 2006, at a Regular Meeting of the Planning Commission of the City of Cupertino by the following roll call vote: AYES: NOES: ABSTAIN: ABSENT: COMMISSIONERS: COMMISSIONERS: COMMISSIONERS: COMMISSIONERS: ATTEST: APPROVED: Steve Piasecki Director of Community Development Marty Miller, Chair Planning Commission g:/planning/pdreport/res/EXC-2006-03 res, doc [) -/D U-2006-0S CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 RESOLUTION NO. OF THE PLANNING COMMISSION OF THE CITY OF CUPERTINO APPROVING A USE PERMIT TO ALLOW THE CONSTRUCTION OF A MULTI-USER PERSONAL WIRELESS SERVICE FACILITY CONSISTING OF A TREEPOLE FOR ANTENNA MOUNTING AND ANCILLARY EQUIPMENT CABINETS LOCATED IN A FENCED ENCLOSURE AT A LOCA TION APPROXIMATELY 600 FEET SOUTHERLY OF MCCLELLAN ROAD ALONG THE UNION PACIFIC RAILROAD CORRIDOR APN 362-01-025 SECTION I: FINDINGS WHEREAS, the Planning Commission of the City of Cupertino received an application for a Use Permit, as described in Section 11 of this Resolution; and WHEREAS, the necessary public notices have been given in accordance with the Procedural Ordinance of the City of Cupertino, and the Planning Commission has held one or more public hearings on this matter; and WHEREAS, the applicant has met the burden of proof required to support said application; and has satisfied the following requirements: 1) The proposed use, at the proposed location, will not be detrimental or injurious to . property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience; 2) The proposed use will be located and conducted in a manner in accord with the Cupertino Wireless Facilities Master Plan, Comprehensive General Plan and the purpose of this title. NOW, THEREFORE, BE IT RESOLVED: That after careful consideration of maps, facts, exhibits, testimony and other evidence submitted in this matter, the application for Use Permit is hereby approved, subject to the conditions which are enumerated in this Resolution beginning on Page 2 thereof; and That the subconclusions upon which the findings and conditions specified in this resolution are based and contained in the public hearing record concerning Application No. U-2006-0S as set forth in the Minutes of the Planning Commission Meeting of May 23, 2006 and are incorporated by reference as though fully set forth herein. 5 -II DRAFT SECTION II: PROTECT DESCRIPTION Application No.: Applicant: Property Owner: Location: U-2006-05 Jim Mattison (for AAT Communications Corp.) Union Pacific Railroad 600 feet southerly of McClellan Road along the Union Pacific Railroad corridor SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPT. 1. APPROVED EXHIBITS Approval is based on Exhibits titled: " as may be amended by the conditions contained in this resolution. . except 2. CO-LOCATION OF ANTENNA The applicant shall make its mast available to other wireless cOmlnunications carriers for antenna co-location subject to the approval of the Director of Community Development under Cupertino Municipal Code Section 19.132. 3. ABANDONMENT If after installation, the aerial is not used for its permitted purpose for a continuous period of 18 months, said antennas and associated facilities shall be removed. The applicant shall bear the entire cost of demolition and removal. 4. EXPIRATION DATE This use permit shall expire five (5) years after the effective date of the permit. The applicant may apply for a renewal of the use permit at which time the Planning Commission may review the state of wireless communication and camouflage technologies to determine if the visual impact of the personal wireless facility can be reduced. 5. TREE POLE APPEARANCE AND MAINTENANCE The applicant shall use a sufficient number of artificial branches to obscure the appearance of the panel antennas and any associated mounting framework. The mast and any panel antenna mounted close to the mast shall be painted brown to mimic a tree trunk. The applicant shall perform regular maintenance of the permitted tree pole to maintain its appearance and obscure the panel antenna from public view. 7. LANDSCAPE SCREEN MAINTENANCE The applicant shall provide for the watering and maintenance of the landscape screen areas for a period of two years. A covenant shall be recorded on the property identifying this landscaping as necessary for the visual screening of the personal wireless service facility and the trees shall not be removed without City approval. 5 -/:< DRAFT 8. NOISE LEVEL OF THE EOUIPMENT CABINETS The equipment cabinets shall conform to the City's Noise Ordinance. Each applicant seeking a personal wireless service facility shall submit a noise assessment indicating its equipment's compliance with the City's noise ordinance. 9. RADIO FREQUENCY RADIATION ASSESSMENTS Each applicant seeking a personal wireless service facility shall submit a radio frequency radiation assessment, indicating estimated ground floor and second floor radio frequency emission exposure levels in relation to Federal safety standards. 10. BASE EQUIPMENT SCREENING A vegetative green color opaque mesh shall be mounted to the fencing in order to screen the base equipment. 11. DE ANZA/UNION PACIFIC TRAIL AND EASEMENT The applicant shall provide an improved asphalt trail from McClellan Road to Rainbow Drive along the Union Pacific Railroad corridor with the granting of an easement for pedestrian and bicyclist public access. PASSED AND ADOPTED this 23rd day of May 2006, at a Regular Meeting of the Planning Commission of the City of Cupertino, State of California, by the following roll call vote: AYES: NOES: ABSTAIN: ABSENT: COMMISSIONERS: COMMISSIONERS: COMMISSIONERS: COMMISSIONERS: ATTEST: APPROVED: Steve Piasecki Director of Community Development Marty Miller, Chair Cupertino Planning Commission g:! planning! pdreport! res!U-2006-05 res approval,doc 5~/3 DRAFT EXC-2006-03 CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 RESOLUTION NO. OF THE PLANNING COMMISSION OF THE CITY OF CUPERTINO APPROVING A HEIGHT EXCEPTION TO ALLOW A 65-FOOT TALL TREEPOLE AT A LOCATION APPROXIMATELY 600 FEET SOUTHERLY OF MCCLELLAN ROAD ALONG THE UNION PACIFIC RAILROAD CORRIDOR SECTION I: PROJECT DESCRIPTION Application No.: Applicant: Location: EXC-2006-03 Jim Mattison (for AAT Communications Corp.) about 600 feet southerly of McClellan Road along the Union Pacific Railroad corridor SECTION II: FINDINGS FOR EXCEPTION WHEREAS, in order to provide height flexibility in situations when collocation of personal wireless service antennas is desirable from a design and visual standpoint, an applicant for development may file an exception request to seek approval to deviate from the standards; and WHEREAS, the Planning Commission finds the following with regards to the Height Exception for this application: 1. That the literal enforcement of the provlSlons of this title will result in restrictions inconsistent with the spirit and intent of this title in that the extra antenna height above the ordinance maximwn is needed to accommodate the collocation of multiple wireless carrier antennas in an area that has proven difficult to serve with wireless communications because of the lack of adequate and snitable sites for personal wireless service facilities that do not create unacceptable visual impacts. 2. That the proposed project will not be injurious to property or improvements in the area nor be materially detrimental to the public health, safety, or welfare in that the wireless technology produces radiation below federal exposure standards on an individual and cnmulative level. The treepole will have minimal visual impact as the pole is adequately screen with existing and proposed landscaping. 3. The proposed development will not create a hazardous condition for pedestrian or vehicular traffic because it is not sited within the travel ways or sight lines of pedestrian or vehicular traffic. NOW, THEREFORE, BE IT RESOLVED: That after careful consideration of maps, facts, exhibits, testimony and other evidence submitted in this matter, application no. EXC-2006-03 is hereby approved; and 5//t-( Resolution No. Page 2 EXC-2006-03 May 23, 2006 That the subconclusions upon which the findings and conditions specified in this Resolution are based and contained in the Public Hearing record conceming Application EXC-2006-03, as set forth in the Minutes of the Planning Commission Meeting of May 23,2006, and are incorporated by reference herein. SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPT. 1. APPROVED EXHIBITS Approval is based on Exhibits titled: " except as may be amended by the conditions contained in this resolution. 2. NOTICE OF FEES. DEDICATIONS. RESERVATIONS OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (I), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90-day approval period in which you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90-day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. PASSED AND ADOPTED this 23rd day of May 2006, at a Regular Meeting of the Planning Commission of the City of Cupertino by the following roll call vote: AYES: NOES: ABSTAIN: ABSENT: COMMISSIONERS: COMMISSIONERS: COMMISSIONERS: COMMISSIONERS: ATTEST: APPROVED: Steve Piasecki Director of Community Development Marty Miller, Chair Planning Commission g :/planning/pdreport/res/EXC-2006-03 res. doc 5~(5 17, 2006 January McClellan Road. \,.1 tl1~ h f r~ n (i )""~f..p;'1 ,..." , \ Ed^ the railroad crossing at based upon information provided by project a.pplicant. Questions Photosimulation of view ~ - ()- January 17, 2006 Photosimulation of view looking due west from the nearby apartment complex. visit ~yy,Pl:LQ.Iº.Slr::!.,COM . ~ F\! \.; b I+-: lhi ,.~."~.~,..,,,.'" Ú"\ , ~ " 17, lOOC January off Bubb Road. 'h~ItIBíT ~( looking due east from across the lake, Proposod multJ..corrier tree pole....... Information provided by project applic;anL Questions Photoslmulatlon of view '1ì ~ <::;¡) 17, 2006 January the nearby apartment complex. looking due west from . 4IfemrJ-ìll.Q., PrOfDSo. SlêDl.-v1Õ- TrœpiJle, shiff visit \W...'l'œH£ 1.877.799.3210 or Photosimulation of view © ~'\ ~ -2:> '4 ¡: \:"1-.\1\1 'pIT: 1..--\..2) '$ ¡ ./MuK'f f7. i\1(I(I, A-1+~~f\J-¡\ý-€.J Prß pOS~~ 0< S~WI~ T('~pt)k Sh/ft- ~,..............,........,_-...,.........u..n"''''.~_'''''''''''''''''.~«''' Cupertino U:CIIICI.., SbNI Cl.lpNfna. C4 MT" -- ...~...'!g 5 -,;(0 £'ihlbìt-: D AA T Communications· Proposed Base Station Southern Pacific Railroad and McClellan Road· Cupertino, California Statement of Hammett & Edison, Inc., Consulting Engineers The firm of Hammett & Edison, Inc., Consulting Engineers, has been retained on behalf of AAT Communications, to evaluate the communications tower proposed to be located at Southern Pacific Railroad and McClellan Road in Cupertino, California, for compliance with appropriate guidelines limiting human exposure to radio ftequency ("RF':) electromagnetic fields. Prevailing Exposure Standards The U.S. Congress requires that the Federal Communications Commission ("FCC") evaluate its actions for possible significant impact on the environment. In Docket 93-62, effective October 15, 1997, the FCC adopted the human exposure limits for field strength and power density recommended in Report No. 86, "Biological Effects and Exposure Criteria for Radiofrequency Electromagnetic Fields," published in 1986 by the Congressionally chartered National Council on Radiation Protection and Measurements ("NCRP"). Separate limits apply for occupational and public exposure conditions, with the latter limits generally five times more restrictive. The more recent Institute of Electrical and Electronics Engineers ("IEEE") Standard C95.1-1999, "Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz," includes nearly identical exposure limits. A summary of the FCC's exposure limits is shown in Figure I. These limits apply for continuous exposures and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health. The most restrictive limit for exposures of unlimited duration to radio ftequency energy for several personal wireless services are as follows: Personal WireJess Service Personal Communication ("PCS") Cellular Telephone Specialized Mobile Radio [most restrictive ftequency range] ADDTOX. Freauency 1,950 MHz 870 855 30-300 Occuoationa1 Limit 5.00 mW/cm2 2.90 2.85 1.00 Public Limit 1.00 mW/cm2 0.58 0.57 0.20 General Facility Requirements Base stations typically consist of two distinct parts: the electronic transceivers (also called "radios" or "channels") that are connected to the traditional wired telephone lines, and the passive antennas that send the wireless signals created by the radios out to be received by individual subscriber units. The transceivers are often located at ground level and are connected to the antennas by coaxial cables about I inch thick. Because of the short wavelength of the frequencies assigned by the FCC for wireless services, the antennas require line-of-sight paths for their signals to propagate well and so are installed at some height above ground. The antennas are designed to concentrate their energy toward HE HAMMETT &: EDISON, INC. CDNSULTWG ENGINEERS SAN FRANCSCO AA TCupertin0596 Page 1 00 5 -,;2./ AAT Communications· Proposed Base Station Southern Pacific Railroad and McClellan Road· Cupertino, California the horizon, with very little energy wasted toward the sky or the ground. Along with the low power of such facilities, this means that it is generally not possible for exposure conditions to approach the maximum pennissible exposure limits without being physically very near the antennas. Computer Modeling Method The FCC provides direction for determining compliance in its Office of Engineering and Technology Bulletin No. 65, "Evaluating Compliance with FCC-Specified Guidelines for Human Exposure to Radio Frequency Radiation," dated August 1997. Figure 2 attached describes the calculation methodologies, reflecting the facts that a directional antenna's radiation pattern is not fully fonned at locations very close by (the "near-field" effect) and that the power level trom an energy source decreases with the square of the distance trom it (the "inverse square law"). The conservative nature of this method for evaluating exposure conditions has been verified by numerous field tests, Site and Facility Description Based upon infonnation provided by AAT Communications, including drawings by URS Corporation, dated January 10, 2006, it is proposed to install a new communications tower to be located south of the intersection of the Southern Pacific Railroad and McClellan Road in Cupertino. Proposed to be installed on the tower are antennas for use by up to three wireless telecommunications carriers although specific carriers and facilities have not been identified. It is assumed that each carrier would install the number of antennas necessary to provide acceptable service in all directions using a standard "three-sector" approach. Therefore for the limited purpose of this study, hypothetical transmitting facilities for the tower are assumed to be as follows: Carrier Cingular Wireless Verizon Wireless Antenna Model (12) Kathrein 742-264 (6) Antel BXA80063-4 (6) Antel BXA185060-8 (9) Decibel DB844H65 Antenna Heieht 65 ft 55 55 45 Maximum ERP 1500 watts 1500 1500 1500 Sprint Nextel SMR Study Results HE For a person anywhere at ground, the maximum ambient RF exposure level due to the various described operations is calculated to be 0.021 mW/cm2, which is 2.5% of the applicable public exposure limit. The maximum calculated level at the second-floor elevation of any nearby building is 3.4% of the public exposure limit. A visual representation of the calculated exposure due to the hypothetical operations is provided in Figure 3. These results are based upon the hypothetical build- out of wireless communications facilities noted above at the proposed site in order to demonstrate that HAMMETI &; EDISON, INC. CONSULTING ENGINEERS SAN FRANCISCO AA TCupertin0596 Page 2 00 5-,.? ~ AAT Communications· Proposed Base Station Southern Pacific Railroad and McClellan Road· Cupertino, California operation of the facility can comply with FCC guidelines for exposure to radio frequency exposure. These results should not be used to represent actual exposure conditions at the site after construction. A complete calculation or measurement analysis of all facilities, once final specifications häve been established, should be perfonned in order to assess compliance with FCC public and occupational exposure guidelines. No Recommended Mitigation Measures Due to their mounting locations, the antennas would not be accessible to the general public, and so no mitigation measures are expected to be necessary to comply with the FCC public exposure guidelines. It is presumed that the several carriers would, as FCC licensees, take adequate steps to ensure that their employees or contractors comply with FCC occupational exposure guidelines whenever work is required near the antennas themselves. Conclusion Based on the infonnation and analysis above, it is the undersigned's professional opinion that the new communications tower proposed by AAT Communications at Southern Pacific Railroad and McClellan Road in Cupertino, California, can comply with the prevailing standards for limiting public exposure to radio frequency energy and, therefore, need not for this reason cause a significant impact on the environment. The highest calculated level in publicly accessible areas is much less than. the prevailing standards allow for exposures of unlimited duration. This finding is consistent with measurements of actual exposure conditions taken at other operating base stations. Authorship The undersigned author of this statement is a qualified Professional Engineer, holding California Registration No. E-16747, which expires on September 30, 2007. This work has been carried out by him or under his direction, and all statements are true and correct of his own knowledge except, where noted, when data has been supplied by others, which data he believes to be correct. February 9, 2006 y Mark D. Neumann, P.E. HE HAMME'IT &: EDISON, INC. CONSUL'J'ß\JG ENGINEERS SAN FRANCISCO AA TCupertin0596 Page 3 of3 5-;)3 FCC Radio Frequency Protection Guide The V,S. Congress required (1996 Telecom Act) the Federal Communications Commission ("FCC") to adopt a nationwide human exposure standard to ensure that its licensees do not, cumulatively, have a significant impact on the environment. The FCC adopted the limits from Report No. 86, "Biological Effects and Exposure Criteria for Radiofrequency Electromagnetic Fields," published in 1986 by the Congressionally chartered National Council on Radiation Protection and Measurements, which are nearly identical to the more recent Institute of Electrical and Electronics Engineers Standard C95.1-1999, "Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz." These limits apply for continuous exposures from all sources and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health. As shown in the table and chart below, separate limits apply for occupational and public exposure conditions, with the latter limits (in italics and/or dashed) up to five times more restrictive: Freauencv Applicable Range (MHz) 0.3 - 1.34 1.34 - 3.0 3,0 - 30 30 - 300 300 - 1,500 1,500 - 100,000 ~ ~ þNa 0._ 0 ~¡!:j::; 0,,::> P-.°a -- 1000 100 10 I 0.1 Electroma!!11etic Fields (f is freauencv of emission in MHz) Electric Magnetic Equivalent Far-Field Field Strength Field Strength Power Density (Vim) (Nm) (mW/cm') 614 614 1.63 1.63 100 100 614 823.81[ 1.63 2. 191[ 100 1801/ 1842/f 823,81[ 4.89/f 2. 191[ 900/t" 180// 61.4 27.5 0.163 0.0729 1.0 0,2 3.54Vr 1.59VJ Vr/106 Vil238 f/300 [/1500 137 61.4 0.364 0.163 5.0 1.0 ./ Occupational Exposure "./' PCS Cell , , FM , ~ /'- Public Ex osure .". ____I - 0.1 1 10 100 103 Frequency (MHz) 105 104 Higher levels are allowed for short periods of time, such that total exposure levels averaged over six or thirty minutes, for occupational or public settings, respectively, do not exceed the limits, and higher levels also are allowed for exposures to small areas, such that the spatially averaged levels do not exceed the limits. However, neither of these allowances is incorporated in the conservative calculation fonnulas in the FCC Office of Engineering and Technology Bulletin No. 65 (August 1997) for projecting field levels. Hammett & Edison has built those formulas into a proprietary program that calculates, at each location on an arbitrary rectangular grid, the total expected power density from any number of individual radio sources. The program allows for the description of buildings and uneven terrain, if required to obtain more accurate projections. HE HAMMElT &: EDISON, INC. CONSULTING ENGINEERS SAN FRANOSCO FCC Guidelines Figure I 5 ~d-lf RFRCALC TM Calculation Methodology Assessment by Calculation of Compliance with FCC Exposure Guidelines The U.S. Congress required (1996 Telecom Act) the Federal Communications Commission ("FCC") to adopt a nationwide human exposure standard to ensure that its licensees do not, cumulatively, have a significant impact on the environment. The maximum pennissible exposure limits adopted by the FCC (see Figure I) apply for continuous exposures /Tom all sources and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health. Higher levels are allowed for short periods of time, such that total exposure levels averaged over six or thirty minutes, for occupational or public settings, respectively, do not exceed the limits. Near Field. Prediction methods have been developed for the near field zone of panel (directional) and whip (omnidirectional) antennas, typical at wireless telecommunications cell sites. The near field zone is defined by the distance, D, /Tom an antenna beyond which the manufacturer's published, far field antenna patterns will be fully fonned; the near field may exist for increasing D until some or all of three conditions have been met: 2h2 I)D>T 2)D>5h 3)D>1.6À where h = aperture height of the antenna, in meters, and À = wavelength of the transmitted signal, in meters. The FCC Office of Engineering and Technology Bulletin No. 65 (August 1997) gives this fonnula for calculating power density in the near field zone about an individual RF source: . S - 180 0.1 x Pnet .. mW 2 power density - !JBW x 7t x D x h' In /em, where SBW = half-power beamwidth of antenna, in degrees, and P net = net power input to the antenna, in watts. The factor of 0.1 in the numerator converts to the desired units of power density. This fonnula has been built into a proprietary program that calculates distances to FCC public and occupational limits. Far Field. OET-65 gives this fonnula for calculating power density in the far field of an individual RF source: d . S 2.56 x 1.64 x 100 x RFF2 x ERP . mW¡ 2 power enslty = 2' In ¡em , 4 x 7tX D where ERP = total ERP (all polarizations), in kilowatts, RFF = relative field factor at the direction to the actual point of calculation, and D = distance /Tom the center of radiation to the point of calculation, in meters. The factor of 2.56 accounts for the increase in power density due to ground reflection, assuming a reflection coefficient of 1.6 (1.6 x 1.6 = 2.56). The factor of 1.64 is the gain of a half-wave dipole relative to an isotropic radiator. The factor of 100 in the numerator converts· to the desired units of power density. This fonnula has been built into a proprietary program that calculates, at each location on an arbitrary rectangular grid, the total expected power density /Tom any number of individual radiation sources. The program also allows for the description of uneven terrain in the vicinity, to obtain more accurate projections. HE HAMMETT & EDISON, INC. CONSULTING EN"GINEERS SAN FRANCSCO Methodology Figure 2 5~)5 AAT Communications· Proposed Base Station Southern Pacific Railroad and McClellan Road· Cupertino, California Calculated NIER Exposure Levels Within 1,000 Feet of Proposed Site For Simultaneous Operation of Three Hypothetical Carriers Aerial photo from Terraserver Legend blank -less than 1% of FCC public limit (i.e., more than 100 times below) ¿mw~;, - I % and above near ground level (highest level is 2.5%) 'i:!Wm, - 1% and above at 2nd floor level (highest Jevel is 3.4%) Calculated using fonTIulas in FC C Office of Engineering Technology Bulletin No. 65 (1997), considering terrain varial ions within 1,000 feet of site. See text for further infonnation. HE HAMMElT &; EDISON, INC. OONSULTING ENGINEERS SAN FRANCISCO AATCupertino596 Figure 3.1 5 - ;l? " To: imattisonía>.sbcqlobal.net Sent: Friday, May 12, 2006 3:14 PM Subject: UPRRlCupertino Cell Tower Jim, Attached is a revised Figure 3 with the corrected base map of 1000- foot radius.? We apologize for the scaling error on the photograph.? Please note that there is no change in the RF exposure levels at ground or on the second floor, still calculated to be well below the applicable public limit.?? In our calculations of power density, we used actual directional antenna patterns from the antenna manufacturers with the maximum effective radiated power in any direction, ?not some lesser power with?an omnidirectional antenna pattern.? The resulting arrangement of the black and red dots on Figure 3 is a clear indicator of the fact that a directional antenna pattern was used.?? Please let me know if you have any other questions. Thanks, Raj Hammett & Edison, Inc. 707/996-5200 voice 707/996-5280 fax 5-:;1 ~ 0 . ~ 1! N i! ~ ~~ !i j ,. ~z 2 ::s~ I ~ s~ ~ s¡ m ~ ~ ~ ò ~ G o - z ~ ~ '-J~ hfl)~ ~ ~~~~ ~~b ~z¡¡¡~ is ~"'~~ '"'"" i3f')f') ~I~~ ~~ 8 ~ ~8!~ ,¡:¡~~ ~O~CII ð N i .~ 8-- GG ~~ i~ii ~ ~~ ~ § ..- CUPERTINO ..- IIoCI.WAN STREET UNION PACFIC RIIILROAD R/W CUPERTINO, CA -- TITLE SHEET AND PROJECT INFORMATION -~ 58-00111003.01 -.. R """"EL -.. - "SHNI - T-1 10-19-2005 - '" NOTED TITLE SHEET AND PROJECT INFORMATION SITE SURVEY SITE PLAN ELEVATIONS SHEET INDEX T- c- A- A-2 THE FACIUTY WIll ENHANCE THE GENERAl HEAlTH, SAFElY AND WELFARE Of THE CIlY BY PROVIDING MORE REUABLE COMMUNICATION AT THIS LOCATION. MT COMMUNICATIONS CORP. ATTN: ALLEN BULLARD 6325 HARRISON DRIVE. SUITE #3 LAS VEGAS, NY 89120 TEL NO. (702) 892-9100 X 225 362-01-025 AAT IS PROPOSING TO MAINTAIN AN UNMANNED WIRELESS TELECOMMUNICATION FACILITY CONSISTING OF A NEW 65'-0" HIGH MONOPINE WITH (4) FUTURE EQUIPMENT PADS WITHIN THE 1650 SOFT FENCED LEASE AREA. UGHT INDUSTRIAL - M RAILROAD RIGHT OF WAY RAILROAD RIGHT OF WAY / TELECOMMUNICATIONS FACILITY McCLEUAN STREET UNION PACIFIC RAILROAD R/W CUPERTINO, CA AAT COMMUNICATIONS CORP. CtNGULAR UNION PACIFIC RAILROAD 1400 DOUGLAS STREET, MAIL STOP 0640, OMAHA, NE 68179 PROJECT DESCRIPTION PROJECT SUMMARY SITE ASSESSOR'S PARCEL NUMBER: PRIMARY LEASE TO: SECONDARY LEASE TO: APPLICANT: CUPERTINO (ZONING DRAWING) PROPERTY OWNER: ZONING: USE: PROPOSED USE: SITE ADDRESS: MULTI-USER (FID NUMBER) CURRENT CURRENT (SITE NAME) TBD ""IE ""IE ""IE IN""'" APPROVAL SIGN OFF ZONING INmALS LANDLORD INITIALS MANAGER) CONSTRUCTlON CONSULTANT 000 (PROJECT SUITE CMI F"NGINFFR· CONTACT: SOHAlL SHAH, P.E. URS CORPORATION 1615 MURRAY CANYON RD., SAN DIEGO, CA 92108 TEL. NO.: (619) 294-9400 FAX NO.: (619) 293-7920 SITF DFVFlOPFR' CONTACT: JIM MArnSON 785 ORCHARD DR~ FOLSOM, CA 95630 TEL NO.: (925) 698-1590 ""IE ""IE ""IE SITE TECH INmALS: INmALS: INmALS: lEASNG RF t TAKE 1-5 NORTH. MERGE ONTO CA-152 WEST TOWARD GILROY/ HOWSTER/SAN JOSE. TURN LEFT ONTO PACHECO PASS HWY /CA-152. MERGE ONTO US-101 N TOWARD SAN JOSE/WATSONVIllE. MERGE ONTO CA-85 N VIA EXIT 377A TOWARD CUPERTlNO/hATN VIEW. TAKE THE STEVENS CREEK BOULEVARD EXIT. TURN LEFT ONTO STEVENS CREEK BLVD. TURN LEFT ONTO BUBB RD. TURN LEFT ONTO MCCLELLAN RD. THE SITE IS CURRENTLY ACCESSED VIA McCLELLAND RD. RD Ii ! . . WoQWAN > ~ ~ :5:BL~ CREEK SITE DIRECTIONS VICINITY MAP u g. I ~ I f;j ~ t! ~ = I i ~ ~ c' ,,~~ hl~lu o o ~ W " .. " ffi z ":¡g ~ Q~¡;;;¡8~E a ~oO>~~8 z c: 0::: (') '~e. w 0 z _ (t '" 0 - Q. 0 0 ~C')I '-' I- 0::: >- ~ d,œ Ie I.) oZw"'«i~ ~ o<)i5~x~ ;¡: it >- z'sJ!!:¡ ~ ~ ~ ~ ~- ~ a: " '" ~ ¡¡ :>.. ~ ~§ ~~ ~~ ~b:¡ ~~ :c:;~ ~ 3c 1O:e.;. ~"cS C) ~~ It:i ~ ~ C ~ ~ ~ ::::¡ ~ C ~ e... ~ I I ...... - C-1 ,._ E COMPOUND DETAIL - ~ 0 50 100 Scale: 1" 50' SYMBOL LEGEND + - Spot _ion ~ -.... . - Wonho6e R/W - RiØ'lt-of-Way I!. - Cent.-tlne . - Iron p.,. Nt œ - T... .......... - Fence Lite ""lor.......... -- ....... í- \-.--- ........ fill \ ~ \ \ \ \ \ \ - \ \ \ \ \ \ \ \ McCLELLAN ROAD _ _ ì - ~ -=- _ 4O'PuÏiÌI:,.Rilht..f.Way _ -/:.- _ -, _ _ 1 I I ! I f I : I I Ii I I I ! I I I I ~ I;; ~I~ O.:F =:':: =II~ ..~ =- ii "C . ,> I , I I I I I I r I I I I I I I I I I I I I I I I SURVEYOR'S CERTIFICATE I, __ ... .....,. 0 CaIIorIIIa ........ ,........ lAnd s..,r. UOMIt Moo 51. ....., licit the .... LoIIIudt IN ....... ..........Cllllllrrl..4 .._-d...___..... +/- 15 IIItIllltlanl1al; -.I tilt 1M..... '-......... II __to"'+1-3"'~ HCIIIZONW.ØI\_ IWJID LAD.Œ 3718'...... ....... ,- 'ÆR1ICM.DA'RIt 1M.... RUllEILV.BASEŒ'JOID-ØJMB. ~ I MILLMAN SURVEYING, INC. CORPORATE HEADQUARTERS 1742 Georgetown Rood, Suite H Hudson, Ohio 44235 (800) 520-1010 ,//'11'11. surveY;ngomerico.com MSI JOB No, 7347 ..............., ~ -,.,.. ...cllllan....of....~1n;. " > ~ o ErinWy - KirwinLn - T' c: REFERENCE RECORD or ~ IIOOIC ... PAGE J4 SITE BENCH MARK TOP RIM (1F IIIN+ICX.E LOCAtED APPROXIMA'laY 80.0 FEET SQU1H aF TI£ SOU1HWEST CORNER ar LEASE MEA AS SHQIMr¡ I£REON. ELEVATION: 3Jt.40 FEET A.M.S.L. BASIS OF BEARING HIiIEJIIIWt~AU.IEllatGSSlll:.tttEJlEØtIS1IEŒJfIEIUI:Œ"1IOtÐ,1OØII ASIElNGN ooœ'cII" E, 1&.... REalI) SUlMYEIOOK" 'AGt54Œs.R'ÐSIM 11£ RECCIIER'S CI'FIŒ Œ SNfTA a.MA CCURY, CM.FtIIIA. LEASE PREMISES DESCRIPTI.QN /' =1 11 ~ ~ -- AIcauIrAv ð ~~ ~, OcNoresAv I L ~ - - :ClltllllnRd ~ r - . t I PrssidOoDr l TT1 0 - HyannisportlX ~y - ... ~ 11 - ~ " . . ~ ÆI RosarioAv . EcrwardWy , - CoIumboJsAv , VICINITY MAP ---:¡;¡:- ~ ~ 8 ~ ~ ¡ J. * N * .!. i!i ~~ Ii! ~~ i ~ ~ f ~ ~i ~ ~i ¡¡¡ ¡¡¡ ~ ~ ¡¡ ~ . ~ m 0 - z .- ClJPERIH) .- IkClfllJN STREIT UNION PACIFIC RAlL.R<:W> R/W CUPERlN). CA -~ 58-00111003.01 -.. R.G.I8REL -.. - s. SIW< - A-1 10-19-2005 - AS NOTED 15'-0" I 10'-0" LEASE AREA FACILITY LAYOUT - SCALE: 1/8" "-0" I \~ I \~ I I SITE PLAN - SCALE: 1" 0'-0" ~ ~ t..J¡;¡ ~o! ~ ~~8~ ~ ~¡;¡'i, h !g~~ :"i ~II!~~ ..... ~-~ "'"'" :;jC..... ~ I~~~ ~ª ~ ~ M~ -, , :N::t1'1 ã!lð~ .~ ~"., i~!i!!i! o ~~ z ~ ;; SITE PLAN - ~ ~ 5'-0" ,<:1 a~ o.w c::~ "'~ ~ ,. I I -+'23/'" WATER PIPE I I I I I I I I I I I I I I I I I I I I I I I I I I I I ---l I I --1 I I I I I I -:¡p,--..... .. ---1"_ . ~.:~ ~~ I #.4'1 ~ wi ~I~ ie¡:j ã:~ ffi~ ~ ---l I I --1 I I I ==~I I --1 I I I I __...J I I I --, I --1 I I I __...J ---H EXISTING ACCESS ROAD I ~ : I I l......\ , " l' PROPOSED PAD-MOUNTED METER PEDESTAl FUTURE 15'-0· X 10'-0" EQUIPMENT PAD FUTURE 8'-0" X 12'-0" EQUIPMENT PAD PROPOSED 8'-0" HIGH- CHAlNUNK FENCE (TYP-ALL AROUND) FUTURE a'-o" X 12'-0" EQUIPMENT PAD FUTURE 10'-0" X 20'-0" EQUIPMENT SHELTER FUTURE ANTENNAS MOUNTED ON A 65'-0" HIGH MONOPINE PROPOSED 12'-0· WIDE ACCESS GATE · œ I ;... b I " '" · '" I ;... ... I ;... · .., I .. · o I ;" b · o I N b I ;... · o I N · o I ... .~ <¡>!1i ~g \ , ~ EXISTING CHAlN- \........- UN" FENCE (TYP) \ \ ~ . \ \ \ \ \ \ \ SCALE NOTE: IF DIt.4EN510NS SHOWN ON PLAN DO NOT SCAlE CORRECTLY, CHECK FOR REDUCTION OR ENlARGEMENT FROM ORIGINAL PLANS. I \ ~ \ RAILROAD TRACKS GRAVEL I I \ I \ I c. -; 'i. "0 t. "" "é> ~' 1" "ß ö I \ II 1\ \\ " II 143s' F: GRAPHIC SCALE 8 . 0 8 16 (SCALE: 1/8- - 1'-Oj 20 GRAPHIC SCALE o 10 - - (selLE: ," _ 10'-0") s 10 14'38' \ \1\ I I I I ~\ , ð ~ ~ 0 :¡: . , ~ ' ¡¡ ~ N - G 2 ' , N S! ~ 1 ~ ¡¡ I~ I ~ I~ ~ Œ ~ ~~ ~ ð n a ~~ ~ 0 ~ ~ ~ ! < m o - -~ 58-00111003.01 -.. .......EL -.. - s._ - A-2 10-19-2005 - AS NO1[) ~ ~ \,)~ ~ ~~ ~ ~~!! N I-~g; ~i~g ~ ti~~ ~ª 8 ª ã~~~ :ÑJ.~ iGlCJI~ ðN I~ g-- Z5~ ~~:i!:i! 2 ~~ ð ~ .- CUPERTINO .- IkCtEWN SIRŒT utICIM PACFIC RAII..R(W) R/W CUPEJm«), CA - ELEVATIONS TOP OF MONOPINE ElEV. 85'-O~ CENTER OF ANTENNAS ELEV.63'-O· CENTER Of ANTENNAS ELEV. 53'-0· FVT1JRE PN\lEl. CENTER OF ANTENNAS ANTENNAS '" O11<ERS ELEV.43'-O· CENTER OF ANTENNAS El.£V.33'-0· PROPOSm MT 65'-0"- HIGH WONOPINE PROPOSED PAD-MOUNTED (DESIGN BV OTHERS) ! 800A MEI'ER PEDESrAL WITH (4)-200A. SlMGLE PHASE BREAKERS. I PROPOSED HOFFW.N PftOPOSED S'-O· HIGH TELCO ENCLOSURE CHAlNUNK F[NCE ON "H" F'RAME (tYP-ALL AROUND) ~ [ GROUND l.E'ÆL - - ELEV. 0'-0" (330'-0· AWSL) PROPOSED 12'-0" WIDE DOUBlE LfAF ACCESS GATE NORTH ELEVATION SCALE: 1· '" s'-o" PROF<JS£'"""""'" TELCO ENCLDSURE ON "H" FRANE PROPOSED PAD-MOUNTED 8I)Gt, WET'ER PEDESTAl WITH(4)-~SINGL.E 1'tiASEBR£>KERS. "" SCALE NOTE: IF DIMENSIONS SHOWN ON PI.AN DO NOT SCALE CORRECTLY, CHECK roR REDUCTION OR ENLARGEMENT FRO" 0RtGI1W... P\..NIIS. ~ TOP OF WQNOPlNE EL£V. 8,5'-0· $ CENTER OF ANTENPW> ELEV. 63'-0· $ CÐITER OF ANTENNAS ELEV. 53'-0" $ CENTER OF ANTENNAS EI..EV.43'-0· $ CENTER OF ANTENNAS ELEV.33'-o" $......' """" EL£V. 0'-0· (330'-0· AMSL) GRAPHIC SCALE 8 4 , 8 18 - - (SCALE: ," _ 8'-0") FUTURE PANEl.. ANTEN'" '" 01HERS ! PROf'OSEO S'-O" HIGH - PROPOSED MT 65'-0" CHAlNUNK FENCE HIGH WONOPlNE (TYP-ALL AROUND) \' (DESIGN BY OTHERS) Im_. I 1_1__U!!m!!rn! !!! :r - EAST ELEVATION SCALE: ,. = 8'-0·