Loading...
SFSFO00492A Post EME Report Radio Frequency — Electromagnetic Energy (RF-EME) Post-Construction Site No. SFSFO00492A SFSFO00492A 6191 Bollinger Road Cupertino, California 95014 EBI Project No. 6223004169 December 1 , 2023 December 1 1 , 2023 f . s Prepared for: Dish Wireless Prepared by: EBI Consulting environmental I engineering I due diligence RF Site Audit Site No. SFSF000492A EBI Project No. 6223004169 6191 Bollinger Road, Cupertino, California EXECUTIVE SUMMARY EnviroBusiness Inc. (dba EBI Consulting) has been contracted by Dish to conduct radio frequency electromagnetic (RF-EME) monitoring for Dish Site SFSF000492A located at 6191 Bollinger Road in Cupertino, California to determine RF-EME exposure levels from wireless communications equipment installed at this site. As described in greater detail in Appendix A of this report, the Federal Communications Commission (FCC) has developed Maximum Permissible Exposure (MPE) Limits for general population exposures and occupational exposures. This report summarizes the results of RF-EME monitoring in relation to relevant FCC RF-EME compliance standards for limiting human exposure to RF-EME fields. EBI field personnel visited this site on December I, 2023. This report contains a summary of the RF EME analysis for the site, including the following: ■ Antenna Inventory ■ Site Photographs ■ Site Plan with antenna locations ■ Graphic representation of onsite monitoring results This document addresses the emissions and signage of Dish's transmitting facilities independently. Emission readings included in this report are cumulative of all carriers on site. However, this report does not address other carrier compliance. STATEMENT OF COMPLIANCE The results of the RF emissions survey indicate that the readings do not exceed applicable FCC MPE limits. An installation is considered out of compliance with FCC regulations if, in an area that exceeds the FCC limits, that installation's contribution is greater than 5% of the applicable MPE and there are no mitigation measures in place. RF Site Audit Site No. SFSF000492A EBI Project No. 6223004169 6191 Bollinger Road, Cupertino, California I. SITE DESCRIPTION Dish has installed RF transmitting antennas at the following location (the "wireless telecommunications facility"): 6191 Bollinger Road, Cupertino, California 95014 SITE ID: SFSF000492A Facility Type: Rooftop Access Restriction(s): Open to Public RF Signage (Existing and Installed) Yes Type(s) and Location: NOC Information & Guidelines —Antenna Enclosure Facility Area Classification: Uncontrolled (General Population) Access to Site Issues: No Roof Access Points Measurement Results Max RF Level at Surrounding 4.6450% of FCC General Population MPE limit Street Level Around Site: FCC Compliance The results of the RF emissions survey indicate that the Conclusion: readings do not exceed applicable FCC MPE limits. EBI Consulting performed an RF emission survey of the RF environment surrounding the facilities installed by Dish at this location. The facility is located on the rooftop of a one-story church. This facility is accessible to the general public. A survey was performed on December I, 2023 to determine the RF emission levels present at the site. Measurements were performed on the areas considered accessible to the general population at the roof level and at ground level surrounding the building. To measure the RF emissions within the vicinity, EBI Consulting utilized a NARDA E Field Probe Model NARD-EA5091 Standard Shaped probe S/N 1201, Frequency Range 300 KHz-50 GHz with NARDA Electromagnetic Survey Meter Model NARDA-NBM-550 S/N G-0009. Probe calibration was performed on June 24, 2022 with meter calibration performed on June 24, 2022. RF Site Audit Site No. SFSFO00492A EBI Project No. 6223004169 6191 Bollinger Road, Cupertino, California 2. ANTENNA INVENTORY The below table outlines the Dish antennas that were observed to be on site during EBI's site walk. Antenna specifications below are based on direct evidence from an antenna or transmitter cabinet, information from the site manager or building manager, information from the licensees, educated estimates by the field technician or a combination of some or all of these sources. "N/A" (not available) is used if any of the following information was not able to be verified. Azimuth Height Above Ant# Type Manufacturer/ Model (o) Ground Level Carrier (feet) Panel JMA/MX08FRO465-20 0 58.5 Dish 2 Panel JMA/MX08FRO465-20 0 58.5 Dish 3 Panel JMA/MX08FRO465-20 120 58.5 Dish 4 Panel JMA/MX08FRO465-20 120 58.5 Dish 5 Panel JMA/MX08FRO465-20 240 58.5 Dish 6 Panel JMA/MX08FRO465-20 240 58.5 Dish RF Site Audit Site No. SFSF000492A EBI Project No. 6223004169 6191 Bollinger Road, Cupertino, California 3. PHOTOS The following photos show the Dish wireless telecommunications facility. ` k Site Overview 3. Dish Equipment Cabinet Access i - i s IN CASE OF W -r EMERGENCY, s,aYea CALL o-h�UenYe��r� 1.866.316.7575 °ra exro-vreunits Site No: 2. Alternate Site Overview 4. Other Carrier Signage RF Site Audit Site No. SFSFO00492A EBI Project No. 6223004169 6191 Bollinger Road, Cupertino, California .r 1 1 1 S. Dish Sector A Overview 8. Dish Sector A Broadcast Direction 6. Dish Sector A Close Up 9. Dish Sector B Overview Y 7. Dish NOC Information & Guidelines Signs 10. Dish Sector B Close Up RF Site Audit Site No. SFSFO00492A EBI Project No. 6223004169 6191 Bollinger Road, Cupertino, California Y� 11. Dish Sector B Broadcast Direction 14. Dish Sector C Broadcast Direction r- 12. Dish Sector C Overview 15. Alternate Site Overview 13. Dish Sector C Close Up RF Site Audit Site No. SFSFO00492A EBI Project No. 6223004169 6191 Bollinger Road, Cupertino, California 4. FIELD MEASUREMENTS 4.1 Roof and Ground-Level Measurements An RF emissions survey was performed at the wireless telecommunications facility. This survey included walking the roof surface and noting the maximum average spatial readings encountered. The maximum value of the average spatial readings of RF emissions encountered on the roof level was 0.0000% of the General Population standard. See Appendix B for the layout depicting the actual readings (% of the FCC MPE General Population standard limit) at various locations at the site. RF Site Audit Site No. SFSF000492A EBI Project No. 6223004169 6191 Bollinger Road, Cupertino, California S. SIGN INSTALLATION Signs are the primary means for control of access to areas where RF exposure levels may potentially exceed the MPE. In order to meet FCC requirements, the signs must: ■ Be posted at a conspicuous point; ■ Be posted at the appropriate locations; ■ Be readily visible; and ■ Make the reader aware of the potential risks rp for to entering the affected area. The table below presents the signs that may be used for Dish installations. NOTICE,& INFORMATION f..n.M faY In�.wrry an This is an ACCESS P01NT la an a w.rr••w r. a rea w it h i ran smillin anlennaa. � .�... Guidelines a NOC Information m,..,.. .�..,r.... _rrw..,wr •l lVa. r..w..v,.... 0(►}} A Blue Notice '"'"...�..r..� Red Warning VVEMM..,.r..\... ._ . . .-. i!*awr.rr� r� ICA004 Yellow Caution r ti�,y 4w.r�ie n[!A4 4�wYVi\Y... ar/r,yrr�\i� w1.rti��N Atw�t�r.•t Mr Based upon guidance provided by Dish, the following signage has been installed on the site (Including any Compliant Existing Signage): ■ NOC Information and Guidelines signs existing on enclosure near Sector A. The signage installed at the site is represented in the photographs presented in Section 3. Posting of the signage was completed per FCC rules and regulations and Dish's corporate RF safety policies. RF Site Audit Site No. SFSFO00492A EBI Project No. 6223004169 6191 Bollinger Road, Cupertino, California 6. CONCLUSION EBI has prepared this Radiofrequency Emissions Report for telecommunications equipment installed at the site located at 6191 Bollinger Road in Cupertino, California. The results of the RF emissions survey indicate that the levels of RF emissions exposure do not exceed applicable FCC MPE limits. The highest level of RF emissions measured on the roof was 0.0000% of the FCC's MPE limits based on the General Population standard. Additionally, the highest level of RF emissions measured at ground level surrounding the building was 4.6450% of the FCC's MPE limits based on the General Population standard. An uncontrolled/general population environment assumes that access to the facility is not generally restricted to authorized personnel and facility management and members of the general public will be able to access the rooftop. 7. LIMITATIONS This report was prepared for the use of Dish. It was performed in accordance with generally accepted practices of other consultants undertaking similar studies at the same time and in the same locale under like circumstances. The conclusions provided by EBI are based solely on the information collected during the site visit and provided by the client. The observations in this report are valid on the date of the investigation. Any additional information that becomes available concerning the site should be provided to EBI so that our conclusions may be revised and modified, if necessary. This report has been prepared in accordance with Standard Conditions for Engagement and authorized proposal, both of which are integral parts of this report. No other warranty, expressed or implied, is made. RF Site Audit Site No. SFSFO00492A EBI Project No. 6223004169 6191 Bollinger Road, Cupertino, California 8. Certification This report was prepared for Dish and serves as certification for current emissions and signage of the existing Dish wireless telecommunications facility. The analysis and information provided is based on applicable FCC regulations concerning RF safety and the control of human exposure to RF emissions. The information and analysis contained in this report are accurate and complete to the best knowledge and belief of the undersigned. Survey Completed by: Y� G December I, 2023 Joseph Vitulli RF-EME Specialist I EBI Consulting Report Prepared by: � Y December 11, 2023 Joseph Vitulli RF-EME Specialist I EBI Consulting RF Site Audit Site No. SFSF000492A EBI Project No. 6223004169 6191 Bollinger Road, Cupertino, California Reviewed and Approved by: Q?,pFESSIO P��- A. MCc� ' 88 m rn o EXP.30SEPa5 - 9 � OF C sealed 12dec2023 Michael McGuire Electrical Engineer mikep.h2dc.com Note that EBI's scope of work is limited to an evaluation of the Radio Frequency — Electromagnetic Energy (RF-EME) field generated by the antennas and broadcast equipment noted in this report. The engineering and design of the building and related structures, as well as the impact of the antennas and broadcast equipment on the structural integrity of the building, are specifically excluded from EBI's scope of work. RF Site Audit Site No. SFSF000492A EBI Project No. 6223004169 6191 Bollinger Road, Cupertino, California Appendix A FEDERAL COMMUNICATION COMMISSION (FCC) REQUIREMENTS The FCC has established Maximum Permissible Exposure (MPE) limits for human exposure to Radiofrequency Electromagnetic (RF-EME) energy fields, based on exposure limits recommended by the National Council on Radiation Protection and Measurements (NCRP) and, over a wide range of frequencies, the exposure limits developed by the Institute of Electrical and Electronics Engineers, Inc. (IEEE) and adopted by the American National Standards Institute (ANSI) to replace the 1982 ANSI guidelines. Limits for localized absorption are based on recommendations of both ANSI/IEEE and NCRP. The FCC guidelines incorporate two separate tiers of exposure limits that are based upon occupational/controlled exposure limits (for workers) and general population/uncontrolled exposure limits for members of the general public. Occupational/controlled exposure limits apply to situations in which persons are exposed as a consequence of their employment and in which those persons who are exposed have been made fully aware of the potential for exposure and can exercise control over their exposure. Occupational/ controlled exposure limits also apply where exposure is of a transient nature as a result of incidental passage through a location where exposure levels may be above general population/uncontrolled limits (see below), as long as the exposed person has been made fully aware of the potential for exposure and can exercise control over his or her exposure by leaving the area or by some other appropriate means. General population/uncontrolled exposure limits apply to situations in which the general public may be exposed or in which persons who are exposed as a consequence of their employment may not be made fully aware of the potential for exposure or cannot exercise control over their exposure. Therefore, members of the general public would always be considered under this category when exposure is not employment-related, for example, in the case of a telecommunications tower that exposes persons in a nearby residential area. Table I and Figure I (below), which are included within the FCC's OET Bulletin 65, summarize the MPE limits for RF emissions. These limits are designed to provide a substantial margin of safety. They vary by frequency to take into account the different types of equipment that may be in operation at a particular facility and are "time-averaged" limits to reflect different durations resulting from controlled and uncontrolled exposures. The FCC's MPEs are measured in terms of power (mW) over a unit surface area (cm2). Known as the power density, the FCC has established an occupational MPE of 5 milliwatts per square centimeter (mW/cm2) and an uncontrolled MPE of I mW/cm2 for equipment operating in the 1900 MHz frequency range. For the Dish equipment operating at 700 MHz, the FCC's occupational MPE is 2.33 mW/cm2 and an uncontrolled MPE of 0.47 mW/cm2. These limits are considered protective of these populations. RF Site Audit Site No. SFSF000492A EBI Project No. 6223004169 6191 Bollinger Road, Cupertino, California Table I: Limits for Maximum Permissible Exposure (MPE) (A) Limits for Occupational/Controlled Exposure Frequency Range Averaging (MHz) Electric Field Magnetic Field Power Density(S) Time [E]z Strength (E) Strength (H) (mW/cmz) [H]z, o (V/m) (Alm) (minutes) s) 0.3-3.0 614 1.63 100* 6 3.0-30 1842/f 4.89/f 900/f * 6 30-300 61.4 0.163 1.0 6 300-1,500 -- -- f/300 6 1,500-100,000 -- -- 5 6 (B) Limits for General Population/Uncontrolled Exposure Frequency Range Averaging (MHz) Electric Field Magnetic Field Power Density(S) Time [E]z Strength (E) Strength (H) (mW/cmz) [H]z, o (V/m) (A/m) ) minutee s 0.3-1.34 614 1.63 100 * 30 1.34-30 824/f 2.19/f 180/f2 * 30 30-300 27.5 0.073 0.2 30 300-1,500 -- -- f/1,500 30 1,500-100,000 -- -- 1.0 30 f= Frequency in (MHz) * Plane-wave equivalent power density FCC Limits for Maxfrrlum Permissible Exposure (MPE) Plane-wave Equwafent Power Oensity OccupationaflContralled Exposure ---- General PopulationlUneontrofied Exposure 100 k 70 � 5 � { � f D.L 0.1. D.03 0.3 } 3 30 300 3,000 30,000 300,000 1.34 1,500 100,000 Frequency (MHz) RF Site Audit Site No. SFSFO00492A EBI Project No. 6223004169 6191 Bollinger Road, Cupertino, California Personal Communication (PCS) facilities used by Dish in this area operate within a frequency range of 600 to 5000 MHz. Facilities typically consist of. 1) electronic transceivers (the radios or cabinets) connected to wired telephone lines; and 2) antennas that send the wireless signals created by the transceivers to be received by individual subscriber units (PCS telephones). Transceivers are typically connected to antennas by coaxial cables. Because of the short wavelength of PCS services, the antennas require line-of-site paths for good propagation, and are typically installed above ground level. Antennas are constructed to concentrate energy towards the horizon, with as little energy as possible scattered towards the ground or the sky. This design, combined with the low power of PCS facilities, generally results in no possibility for exposure to approach Maximum Permissible Exposure (MPE) levels, with the exception of areas directly in front of the antennas. MPE limits are designed to provide a substantial margin of safety. These limits apply for continuous exposures and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health. RF Site Audit Site No. SFSFO00492A EBI Project No. 6223004169 6191 Bollinger Road, Cupertino, California Appendix B Field Measurements and Site Layout I tSectorA 4.645 4.258 i Equipment 0.635 4.0865 2.8115 3.1715 3.903 1.083 2.403 1 3.069 3.5465 3.668 2.96 Sector C 2.8025 2.551 �-- P__ 2.245 Sector B 1.135 ` c ,� �•a e•a 60' Site Plan with Monitoring Results LEGEND Facility Operator: Dish Wireless Site Number: SFSFO00492A Dish Antennas Site Visit Date: 12-01-2023 ♦ Green numbers are Spatially-Averaged Measurements %FCC General Public Limit EBI Consulting environmental l engineering i dae diligence