DIR-2022-011 - EMF Report SF15002A EME Com n' te1(p ee t Department
P130r rjpgsRi�r jrDn5Cupertino
curertrJNa npoRnIiGn YOUR RF SAFETY PARTNER
Case# D I R-2022-011
RAM" W' ft_NCY ELECTROMAGNETIC FIELDS EXPOSURE REPORT
Approval Body: Director/Staff
Approva I Date 07/13/22 PRE-Activation
Signature Jeffrey Tsumura Prepared for T-Mobile
Case Manager
Site Name: PG&E Monta Vista Sub
Site ID: SF15002A
Site Type: Powerline Tower
Located at:
10110 California Oak Way
Cupertino, CA 95014
Latitude: 37.32507003 / Longitude: -122.076807
Report Date: 1/27/2022
Report By: Christopher Stollar, P.E.
Based on FCC Rules and Regulations, T-Mobile will be compliant provided
recommendation(s) are implemented.
Page 1/14
(T6r]M W� -rnn�irk pp hcctuuD�e rp��a rt m e nt
1.0 PEXETI�ViMMA�Y..ino................................................. 3
CUPERTIN02.0 SITE DIAMW1 *..........................................................................................................................................4
Case # 2.1 SiteWPp,2M-0.1.1............................................................................................................................................4
2.2 Anvoinaiinvamwq).............................................................................................................................................5
3.0 ANALYSIS..............................................................................................................................................................6
Aproval4dyEqiigsfl'Plreffons.........................................................................................................................................6
Aproval(Date-OAII*WN.....................................................................................................................................................9
Sinature4.1 i 'fsumura.......................................................................................................................................................9
ecos)...........................................................................................................................................9
4.3 Statement of Compliance................................................................................................................................11
4.4 Engineer Certification......................................................................................................................................11
AppendixA: Background..............................................................................................................................................12
Appendix B: Measurement and/or Computer Simulation Methods.....................................................................13
AppendixC: Limitations ...............................................................................................................................................13
Appendix D: Sample T-Mobile RF Advisory Signs..................................................................................................14
•
Dtech
communcaions 5850 Oberlin Drive,Ste.300 ♦ San Diego,CA 92121 ♦ 858.792.0066♦ www.dtechcom.com Page 2/14
MrVMM4V&W-"9AdMpartment
PI nnin Division— ��i q
Dtech �omm�mcations,LL� tech� has been retained by Smartlink,LLC, contractors to T-Mobile, to
car aT'Nodetermine whetA_PrPRq Pss communications facility complies with the Federal Communications
Ca se# CommissiodL i'REXO?R4%1 Frequency ("RF") Safety Guidelines. This report contains a computer-
simulated aApr y6ti iccafNrAlrixb rcFkctromagnetic Fields ("EMF' exposure resulting from the facility. The analysis
also includes assessment of existing wireless carriers on site,where information is provided. The table
A provjj�f� ,P ff#5 ttA46s at a glance:
A proval Date 07/13/22
Si nature Jeffrey Tsumura Table /:EMFSummarg
T-M
o.
Access Tye Climbing Pegs
Access to antennas locked NA
RF Sign(s) @ access point(s) NOC, Guidelines &Warning
(Recommended)
RF Sign(s) @ antennas None
Barrier(s) @ sectors NA
Max EMF level for 2.4% General Population
T-Mobile on Ground
Max EMF level for 0.4% General Population
T-Mobile on Adjacent Building Roof
Min Clearance Distance from Face of 98 Feet
T-Mobile's Antennas
•
Dtech
communcaions 5850 Oberlin Drive,Ste.300 ♦ San Diego,CA 92121 ♦ 858.792.0066♦ www.dtechcom.com Page 3/14
�c�rr� ri ►# I � t Department
The P�aPnsn�Dommunicationetac�ilnity is located on the ground. The facility consists of 1 wireless
CUP RTINQcarrier(s) or opARR�q- `IEPIobile.The antennas are typically grouped into sectors pointing in different
C se# directions to[3 URie3r@212eQdSlred areas of coverage. T-Mobile's antennas are mounted on a powerline tower
and connecc&90itaiohvwTaP-6i lnent via coaxial cables.
A provaI B2dy$j?jrM r/ Staff
A prova I Date 07/1�/22
Signature ,
'F� A-
�• Q +
r►.
r
�� f� • � b`k - -
v
Dtech
communcaions 5850 Oberlin Drive,Ste.300 ♦ San Diego,CA 92121 ♦ 858.792.0066♦ www.dtechcom.com Page 4/14
Attf Department
n on- URFcnl0
The tPo �e e� re sectstto n , specifications provided by our clients and/or gathered from physical
cUr ItTIN°field surveys wINeP* Ple. This final configuration',including power settings and antenna orientations
C se# must be maid 2)ki%in compliance with FCC guidelines. For co-locators or nearby transmitters,
cons ervativepp9 owimgr*er(a)sed for purposes of a cumulative study where information is not provided or
available.
A proval Body: Director/ Staff
Approval Date 07/13/22
. Site Technical Specifications
Signature
Bottom Tip Bottom Tip Bottom Tip
Antenna cd5 Manager Frequency Orientation Horizontal Antenna Antenna Total ERP Height Above Height Above Height Antenna
ID Operator Antenna Mfg Antenna Model Type (MHz) Technology (°T) BWdth(°) Aperture(ft) Gain(dBd) (Watts) Ground(Z)(ft) Adj.Roof(Z)(ft) Level(Z)(ft)
Al T-Mobile Ericsson AIR6449 Panel 2500 NR 340 13 _2.8 22.4 34367 58.6 43.6 0.0
Al T-Mobile Ericsson AIR6449 Panel 2500 LTE 340 13 2.8 22.4 20620 1 58.6 1 43.6 0.0
A2 T-Mobile RFS APXVAALL1843-U-NA20 Panel 600 LTE 340 66 6.0 11.7 3148 1 48.0 1 33.0 0.0
A2 T-Mobile RFS APXVAALL1843-U-NA20 Panel 700 LTE 340 62 6.0 12.3 2416 1 48.0 33.0 0.0
A2 T-Mobile RFS APXVAALL1843-U-NA20 Panel 1900 GSM/LTE 340 62 6.0 15.1 9061 48.0 33.0 0.0
A2 T-Mobile RFS APXVAALL1843-U-NA20 Panel 2100 LTE 340 55 6.0 15.5 7677 48.0 33.0 0.0
B1 T-Mobile Ericsson AIR6449 Panel 2500 NR 90 13 2.8 22.4 34367 58.6 43.6 0.0
B1 T-Mobile Ericsson AIR6449 Panel 2500 LTE 90 13 2.8 22.4 20620 58.6 43.6 0.0
62 T-Mobile RFS APXVAALL1843-U-NA20 Panel 600 LTE 90 66 6.0 11.7 3148 48.0 33.0 0.0
B2 T-Mobile RFS APXVAALL1843-U-NA20 Panel 700 LTE 90 62 6.0 12.3 2416 48.0 33.0 0.0_
B2 T-Mobile RFS APXVAALL1843-U-NA20 Panel 1900 GSM/LTE 90 62 6.0 15.1 9061 48.0 33.0 0.0
B2 T-Mobil FS APXVAALL1843-U-NA20 Panel 2100 LTE 90 55 6.0 15.5 7677 48.0 33.0 0.0_
Cl T-Mobile Ericsson AIR6449 Panel 2500 NR 180 13 2.8 22.4 34367 58.6 43.6 0.0_
C1 T-Mobile Ericsson AIR6449 Panel 2500 LTE 180 13 2.8 1 22.4 20620 58.6 43.6 0.0
C2 T-Mobile RFS -� XVA APALL1843-U-NA20 Panel 600 LTE 180 66 6.0 11.7 3148 48.0 33.0 0.0_
C2 T-Mobile RFS APXVAALL1843-U-NA20 Panel 700 LTE 180 62 6.0 12.3 2416 48.0 33.0 0.0_
C2 T-Mobile RFS APXVAALL1843-U-NA20 Panel 1900 GSM/LTE 180 62 6.0 15.1 9061 48.0 33.0 0.0
C2 T-Mobile RFS APXVAALL1843-U-NA20 Panel 2100 LTE 180 55 6.0 15.5 7677 48.0 33.0 0.0
1 Per T-Mobile direction,the AIR6449 ERP's were calculated with an input power of 20OW for NR and 120W for LTE.
•
Dtech
communcaions 5850 Oberlin Drive,Ste.300 ♦ San Diego,CA 92121 ♦ 858.792.0066♦ www.dtechcom.com Page 5/14
MnWO&Nsffevelopment Department
3Plapmisonrec�icnonpertino
CUP RTINO APPROVED
Ca 5e# Figure 1:Plan P n22w04A of results compared to FCC's General Population MPE (Maximum Permissible Exposure)Limits
for a typical 6 0i ip gimc&t�i e represents areas where exposure levels are calculated to be at or below 5%;Green-between 5% d�
100% (below MPE limits);blue,yellow&red—greater than 100% (exceeds MPE limits). Individuals can safely occupy areas in white
A proval BAae o tzi�otar.,h6Sta#time;whereas areas in blue,yellow&red must be restricted to BF trained personnel who has been made
A prow pMe ofp��r{i�p�g'jf22exposure, has control and knows how to reduce their exposure with the use ofpersonalprotectzon equpment or
as t e a iVy to power ilown 7he transmaters.
Si nature Jeffrey Tsumura
Case Manager %of FCC General Public Exposure Limit
� X:55 I ■ 5<X:5100 N 100<X5500 500<X55,000 ■ X>5,000
Simulation Diagram
4
ML
L
Groun
to
a
i
i4
a
Wi
d "
3 B
Aj Climbing
L
Pegs L
}iSV�}TL' L
1
evi 1)
XA
.Adj.Bldg.
(Roof
G ound
Ground Level MaxSim Levels •T-Mobile 6
N IF Elevatioriff T-Mobile:2,41%
Grid Size=10It
•
Dtech
comm°ncaions 5850 Oberlin Drive,Ste.300 ♦ San Diego,CA 92121 ♦ 858.792.0066♦ www.dtechcom.com Page 6/14
C � {' / 1�� f�pp �rto FCC's General Population MPE (Maximum Permissible Exposure)Limits
for a ty cal 6 oot t l erspn. bVhtt re resents areas where exposure levels are calculated to be at or below S%;Green-between 3% &
900%'( �vE �t`�,Qe,y �t} crc greater than l00% (exceeds MPE limits). Individuals can safely occupy areas in white
CUr F BTINo andgreen for indefinAp ,0 Dve;whereas areas in blue,yellow&red must be restricted to BF train ed personnel who has been made
C se# 4�1� ''�'1
fully aware ofp l o has control and knows how to reduce their exposure with the use ofpersonal protection egu pment or
��izrrh�ir rrirccirp" rt�ia*ir nr.+titter.�-
Ap lication Number(s�
A prova I Body: Directo taff %of FCC General Public Exposure Limit
A prova I Date
07/13/2221
5 5 I ■ 5<X<_100 . 100<X 5 500 500<X 5 5,000 I ■ X b,5,000
Si unature J re Tsumura Simulation Diagram
Case Manager
■■■F5
' �■a`
1
Groun
4Gro
6
41
1
1
A "a
l
7
Wf
` 3 �
B
ti
Climbing
Pegs �
(Ro f Lev q
GrDund
Adj.Bldg. Roof Max Sim Levels •T-Mobile 161
N IF Elevation:15' T-Mobile:0.4%
Grid Size=10 ft (On Adj.Bldg.Roof)
•
Dtech
communcaions 3830 Oberlin Drive,Ste.300 ♦ San Diego,CA 92121 ♦ 838.792.0066♦ www.dtechcom.com Page 7/14
C � { i/ VE�� �pp �rto FCC's General Population MPE (Maximum Permissible Exposure)Limits
for a ty cal 6 oot t l erspn. bVhtt re resents areas where exposure levels are calculated to be at or below S%;Green-between 3% &
900%'( �vE �t`�,Qe,y �t} crc greater than l00% (exceeds MPE limits). Individuals can safely occupy areas in white
CUP F BTINo andgreen for indefitAP .O Dve;whereas areas in blue,yellow&red must be restricted to BF train ed personnel who has been made
C se# 4�1� ''�'1
fully aware ofp l o has control and knows how to reduce their exposure with the use ofpersonal protection egu pment or
�5zr�h5r arnccirp' rt� r».itter.�-
Ap lication Number(s�
A prova I Body: Directo taff %of FCC General Public Exposure Limit
A prova I Date
07/13/2221
I ■ 5<X<_100 ■ 100<X5500 500<X55,000 IN X b,5,000
Si unature J re Tsumura Simulation Diagram
Case Mana 8er
MEN ■■■■■■■■■■■■■
■■ ■MEMO ■■■E■■ ■
■■ MEN NONE■■
■■E■ No
N■■■■■
■ENE■ NEE■■■■■■■■■
■■■■■ IMMMMMMMM
A
■
■■■■■W A
■■■■■■L :
■■NONE r3 B 1000■■
■ EL --
peg,ifi■■■■■1.
_■� ■■■■■■■■
Adj.Bldg. EF (^, MEN■■■NEE
` A(Roof Le"el) ■L 4EEEEEEEEE
NOON ■■■■■■■■■■
d■■■■ ■■■■■■■■■■■
I■■■■ ■■■■■■■■■■
E■■■■ ■■■■■■■■■■■ .
�IIIIIIIIIL��.-.�� ��■■_
/ Antenna Level Max Sim Levels •T-Mobile 6
N Elevation:48' T-Mobile:8612.0%
Grid Size=10It
•
Dtech
comm°ncaions 3830 Oberlin Drive,Ste.300 ♦ San Diego,CA 92121 ♦ 838.792.0066♦ www.dtechcom.com Page 8/14
M MNR' J�WNpment Department
Pla nin, Division — Cupertino
4.1 Resu�ts
CUPERTINO APPROVED
Case# For a persorDQ6Z0g2-r0dAssible areas on the ground and adjacent building roof, calculations for
T-Mobile's 4oc-aift1mod 6wexposure levels below the FCC's most stringent General Population MPE Limits
(see figure 1 - 2).
Approval Body: Director/Staff
A provddd latdina 974 W the highest calculated exposure level is above the FCC's General Population MPE
Si gnat4 ts %*4eTTu-�b�ile antenna(s) (see figure 3). The overexposed (red,yellow and blue) areas extend
98- eet trom t igg of the T—oGTe—antenna(s). From the provided drawings,there are no other
buildings or surrounding structures at antenna elevation within 98-feet of the T-Mobile antenna(s). Beyond
98-feet, exposure levels are predicted to be below the FCC's most stringent General Population MPE
Limits.
The antennas are mounted on a tall tower and therefore not accessible by the general public. It is presumed
that T-Mobile employees and contractors are aware of the transmitting antennas and will take appropriate
precautions when working near them. However, there may be situations where workers i.e. power-line
workers, etc. may find themselves directly in front of the antennas. Individuals working near/in front of
antenna(s) must receive appropriate RF safety training and be made aware of the HotZones (areas where RF
exposure may potentially exceed FCC safety limits). In addition, contact information should be made
available in the event work is required within the HotZones. Alternatively, if the need occurs for any
maintenance personnel to work directly in front of the antennas,T-Mobile should be contacted to arrange
for the power to be shut down during the work period.
4.2 Recommendation(s)
The following compliance action(s) would be sufficient to meet the FCC's RF Safety Guidelines
(see figure 4):
1) Install RF advisory signs according to the Recommendation diagram.
•
Dtech
communcaions 5850 Oberlin Drive,Ste.300 ♦ San Diego,CA 92121 ♦ 858.792.0066♦ www.dtechcom.com Page 9/14
t6mMuKftNr0,evWopMent Department
Planning Division — Cupertino
CUPERTIINQ APPROVED
Recommendation Diagram
Case # -20 -
pplication Numb r(s) i
*4
A prova I Body. D rector Staff `+
A prova I Date 7/13/2
Si wature leffrDv TsUML ra Groin
k
L
as ellii Ianag r ,
5
t
i
�py 4
hA AL
1
L
I L
0 B .,
Climbing
�
r ■r Pegs
N.a&S:NO`
1 Adj.Bldg.
(Roof Level)
ound
101 T-Mobile 6
Grid Size=10 ft
•
Dtech
communcations 5850 Oberlin Drive,Ste.300 ♦ San Diego,CA92121 ♦ 858.792.0066♦ num.dtechcom.com Page 10/14
Co Mrp•�l u%i�VDw61(6 i t1 wpa rtment
Based onn hle bDo el results anRysisiand recommendation(s),it is the undersigned's professional opinion
CUr RT1Nothat T-Mobile'sWNYWompliant with the FCC's RF Safety Guidelines provided recommendation(s) are
C se# implemente(DIR-2022-011
Application Number(s)
A proval B�.qy.j�a' ii pre*cation
Approval Date 7/13/22
Si matAbis reDo tr&Th%grPrepared by or under the direction of the following Registered Professional Engineer:
Darang'I ech, hoKUMgnto nr is registration number 16000. I have reviewed this report and believe it to be
both true and accurate to the best of my knowledge.
OFE551p
CO
w E16 0 T
* EXR G L3
sr
grFOr CAL�FAQ�
•
Dtech
communcaions 5850 Oberlin Drive,Ste.300 ♦ San Diego,CA 92121 ♦ 858.792.0066♦ www.dtechcom.com Page 11/14
O& fuiffify-CJ?eWjI10 1e-(tt Department
Planni pp� ion.—CCu e�mo
Dtech uses t�i F(� �'s defin�s described in detail in Office of Engineering&Technology, Bulletin No. 65
CUP RTINO("OET-65") "E' �i�Wmpliance with FCC Guidelines for Human Exposure to Radiofrequency
Ca se# ElectromagrDUR420221:044e table below summarizes the current Maximum Permissible Exposure
("MPE") sAirt�dils4itsuaihWified into two groups: General population and Occupational.
A prova I Body: Director/ StafF
A prova I Date 07/13/22 Table 3:FCC MPE Limier(from OET-65)
SI nature I Jeffrey Tsum raML(
se K anag-
• .
Time
minutes
• '
I
30- 300 0.2 30 1.0 6
300 - 1500 Frequency (Mhz)/1500 30 Frequency (Mhz)/300 6
(0.2— 1.0) (1.0— 5.0)
1500 - 1.0 30 5.0 6
100,000
General population/uncontrolled limits apply in situations in which the general public may be exposed or
in which persons who are exposed as a consequence of their employment, and may not be fully aware of the
potential for exposure or cannot exercise control over their exposure. Therefore, members of the general
public always fall under this category when exposure is not employment-related.
Occupational/controlled limits apply in situations in which persons are exposed as a consequence of their
employment, and those persons have been made fully aware of the potential for exposure and can exercise
control over their exposure. Occupational/controlled limits also apply where exposure is of a transient
nature as a result of incidental passage through a location where exposure levels may be above general
population/uncontrolled limits, as long as the exposed person has been made fully aware of the potential
for exposure and can exercise control over his or her exposure by leaving the area or by some other
appropriate means.
It is important to understand that the FCC guidelines specify exposure limits not emission limits. For a
transmitting facility to be out of compliance with the FCC's RF safety guidelines an area or areas where
levels exceed the MPE limits must, first of all, be in some way accessible to the public or to workers. When
accessibility to an area where excessive levels is appropriately restricted,the facility or operation can certify
that it complies with the FCC requirements.
•
Dtech
communcaions 5850 Oberlin Drive,Ste.300 ♦ San Diego,CA 92121 ♦ 858.792.0066♦ www.dtechcom.com Page 12/14
CVV#W"MVtt®t_#Agtr1F,@ftputer Simulation Methods
Piannin Division—Cupertino
Spatial average�measurement technique is used. An area between 2 and 6 feet, approximately the size of
CVr RTINOan average hum PsRsQAPd in single passes from top to bottom in multiple planes. When possible,
Case# measuremenglRe2D22clOAdvery close proximity to the antennas and inside the main beam where most of
the energy i&,wDthcitiwdiur' c(s6patial averaged values were recorded.
A prov?PNX;ARr ARE/tr ndard power density prediction computer Model'to assess the worse-case,
A provaMMWive 9_7412Ract of the surrounding areas of the subject site. In addition, the analysis is performed
Si natu4100% c-Y 1�dtransmitters are active at all times and transmitting at maximum power. For purposes
of a cumulative ,rqk* y transmitters are included where possible. The result is a surrounding area map
color-coded to percentages of the applicable FCC's MPE Limits. A result higher than 100% exceeds the
Limits.
Appendix C: Limitations
The conclusions in this document rendered by Dtech are based solely upon the information collected during
the site survey and/or furnished by our Client which Dtech believes is accurate and correct. Dtech,
however,has no responsibility should such Client provided information prove to be inaccurate or
incorrect. Third party specification estimates used for cumulative computer simulation purposes,where
applicable, are based on common industry practices and our best interpretation of available information.
Data,results and conclusions in this document are valid as of its date. However, as mobile technologies
continuously change,these data,results and conclusions may also be at variance with such future changes.
Dtech has no responsibility to update its survey or report to account for such future technology changes.
This document was prepared for the use of our Client only and cannot be utilized by any third party for any
purpose without Dtech's written consent. Dtech shall have no liability for any unauthorized use of this
document and any such unauthorized user shall defend,indemnify and hold Dtech and its owners, directors,
officers and employees harmless from and against any liability, claim, demand,loss or expense (including
reasonable attorney's fees) arising from such unauthorized use.
2 Roofmaster(tm)
•
Dtech
communcaions 5850 Oberlin Drive,Ste.300 ♦ San Diego,CA 92121 ♦ 858.792.0066♦ www.dtechcom.com Page 13/14
D� 1C �ret�� h�itisory Signs
Planning Division — Cupertino
CUPERTINO APPROVED
Case #
Appl cation I) i beWTICE /Iil,�\
p�Gl11DELINES FOR WORKING ONM IN 'N CASE OF
Approval Body: Dire nr .P.y. dIn—.—tr.—ONMENTS
7u personne uld have eUENCYlectromagnetic eur—gy
A proval Date 07 1=}ovrnanreh ringths sit.must beauthorized. EMERGENCY
0 A wall antennas are alive.Si nature Jeffrey}SLRTINbrgkin nantennas,notify Dwnersanddsable CALL
LO pjr) f3feetclearancefromallanitemas -888_662 4662
rrPPii nt of antennas.
•t/se personal RF monitors while working new
anlerinas. site HIM
!serer operate transmitters wthout shlatds during
normal operation. Site Narnm
!Do not oparater bass station antennas in equipment
morns.
NOC Sign
GUIDELINES Sign
• ACAUTION
(• ��w)�
. 1
Beyond this point:
Radio point
m ycy fields beyond Radio frequency fields at this site
this point may exceed the FCC may exceed FCC rules for human
general public exposure limit. exposure.
Obey all posted signs and site guidelines For your safety,obey all posted signs and
for working In radio frequency site guidelines for working in redlo
aerironmenta.
frequency ernironmanta.
NOTICE Sign CAUTION Sign
AWARNING
Beyond this point:
Radio frequency fields at this site
exceed the FCC rules for human
¢xposura.
Failure to obey all posted signs antl site
guidelines for Working in radio fregeeecy
environments could result in serious injury.
WARNING Sign
3 The above signage is for reference only. Actual signs may be updated in accordance to T-Mobile RF policy. See cover page for site specific information.
•
Dtech