Loading...
TUP-2021-003 - Approval Set Community Development Department Planni g Division — Cupertino CUPERTINO APPROVED Case # I U P-2021-003 Ap lication Number(s) Approval Body: Director/ Staff TEMPORARY SKYLIGHT MOCKUP Approva I Date 0 /06/22 Signature Jeffre Tsumura Case Manager GENERAL NOTES CODE INFORMATION DRAWING LIST P1 PROVIDE TREE PROTECTION FOR PROPERTY LINE 1. DO NOT SCALE THE DRAWINGS. AUTHORITY HAVING JURISDICTION: THE CITY OF CUPERTINO, CALIFORNIA A-001 GENERAL INFORMATION TWO TREES ADJACENT TO A-002 TREE PROTECTION DETAILS MOCKUP AS PER CITY OF 6' HIGH CHAINLINK CONSTRUCTION FENCING WITH BLACK SCRIM, 2. VERIFY FIELD CONDITIONS PRIOR TO COMMENCEMENT OF EACH PORTION OF WORK. A-100 PLANS, ELEVATIONS, AND DETAILS CUPERTINO STANDARD DETAILS PROVIDE (2) 3'-0" MIN WIDTH EXITS LOCATED AS SHOWN. D E F F E R E D SUBMITTALS P1 6-2 AND 6-4 TEMPORARY STRUCTURE LOCATION, 3. THE CONTRACT DOCUMENTS ARE COMPLIMENTARY, AND WHAT IS REQUIRED BY ONE � I� SEE 1/A-100 jFOR PLAN SHALL BE AS BINDING AS IF REQUIRED BY ALL. THE CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE WORK AS DESCRIBED IN THE CONTRACT T , BUILDING PERMIT 50 SETBACK REQUIRED AT RESIDENTIAL ZONES, DOCUMENTS. NOTIFY THE ARCHITECT FOR RESOLUTION OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. I - �; 'NO SETBACK REQUIRED AT ML ZONES 4. DIMENSIONS SHOWN AS 'VIF' SHALL BE VERIFIED BY THE CONTRACTOR IN THE FIELD BY LAYING OUT THE PARTITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES IN PROJECT INFORMATION � A S. DIMENSIONS PRIOR TO PROCEEDING WITH WORK. �\ 5. DIMENSIONS SHOWN AS 'CLEAR' OR 'HOLD' SHALL BE MAINTAINED AND ALLOW FOR LTS WAY, CUPERTINO, CA 95014 THICKNESS OF FINISHES; INCLUDING FLOOR FINISHES. NOTIFY ARCHITECT OF ANY N: 3 20 6 ------------- 147'-0» DISCREPANCIES IN DIMENSIONS PRIOR TO PROCEEDING WITH WORK. PARCEL AREA: 212,758 SF P,, _ - 14 OUT OF 1,241 VAILABLE ZONI G: P(ML) n;-� PARKING SPAC WILL BE TEMPORARILY 6. DIMENSIONS ARE TO THE STRUCTURAL GRID OR TO FINISH SURFACES, UNLESS --- UNAVAILABLE WHILE THE MOCKUP IS IN OTHERWISE INDICATED. AREA OF GLAZING PANELS 172 SF `."I 152'-3 7 8" I, ` PLACE AREA OF SCAFFOLD STRUCTURE 840 SF - 7. THROUGHOUT THIS SET OF DRAWINGS, THE TERM "OWNER" REFERS TO THE III ! '11 <- ; 344,185 SF OF OFFICE ON SITE CLIENT/TENANT. THE TERM LANDLORD" REFERS TO THE PROPERTY OWNER. THE P1 /285 SF = 1208 REQUIRED PKG SPACES TERM "DM" REFERS TO THE OWNER'S REPRESENTATIVE DURING CONSTRUCTION. P1 PROJECT DESCRIPTION -IIr 1241-14 = 1227 PKG SPACES AVAILBLE 12. OWNERSHIP AND USE OF DOCUMENTS: i { WHILE MOCKUP IS IN PLACE THIS IS AN INSTRUMENT OF PROFESSIONAL SERVICE AND SHALL REMAIN THE 1 - LO PROPERTY OF BOHLIN CYWINSKI JACKSON WHETHER THE PROJECT FOR WHICH IT IS CONSTRUCTION OF A TEMPORARY STRUCTURE TO SUPPORT 8 SKYLIGHT GLAZING PANELS AS __ M s MADE IS EXECUTED OR NOT. NO CHANGES, ALTERATIONS, ADDITIONS, OR DELETIONS A MOCKUP FOR REVIEW OF AESTHETIC APPEARANCE. GLAZING PANELS WILL BE ATTACHED TO A SCAFFOLD STRUCTURE DESIGNED BY A LICENSED ENGINEER. STRUCTURE IS EXPECTED TO REMAIN IN PLACE FOR APPROX. TWO WEEKS FOLLOWING COMPLETION, AFTER WHICH IT MAY BE MADE HERETO EXCEPT BY THE ARCHITECT AND THIS SHALL NOT BE USED OR J ! � _,` FORRCOOMPLDETION BY AN OFYOH S OPROJECT BYN OTHER ROTHERS WIOHOUTDTHONTTEEXPRESSS TO THIS WRITTENPROJECT OF 1 IJ 12 RESULTS WAY ENTRANCE WILL BE REMOVED BY THE CONTRACTOR. THE STRUCTURE IS NOT INTENDED FOR USE OR CONSENT OF BOHLIN CYWINSKI JACKSON. SUBMISSION OR DISTRIBUTION TO MEET OCCUPANCY AND ACCESS WILL BE RESTRICTED TO AUTHORIZED PERSONNEL ONLY. - 0 � REGULATORY REQUIREMENTS OF FOR PURPOSES IN CONNECTION WITH THIS PROJECT DISTURBANCE TO THE SITE WILL BE LIMITED TO THE MINIMUM NECESSARY TO INSTALL THE - - IS NOT CONSTRUED AS PUBLICATION IN DEROGATION OF THE RIGHTS OF BOHLIN SCAFFOLDING AND FENCING (TREES AND PAVEMENT WILL NOT BE DISTURBED), AND IT WILL " CYWINSKI JACKSON. BE RETURNED TO ITS PREVIOUS CONDITION FOLLOWING REMOVAL OF THE TEMPORARY ° p 1 13. GENERAL CONTRACTOR TO OBTAIN AND PAY FOR ALL PERMITS, INSPECTIONS, AND STRUCTURE. p AND FINAL SIGN OFFS REQUIRED BY THE GOVERNING AUTHORITIES GOVERNING THE WORK. 14. ALL WORK AND MATERIALS SHALL BE IN FULL CONFORMANCE WITH THE LATEST FEDERAL, STATE, AND LOCAL BUILDING CODES AND ORDINANCES, INCLUDING THEIR PROJECT DIRECTORY L MOST RECENT REVISIONS, ADDITIONS, AMENDMENTS, AND INTERPRETATIONS. IN THE 1 , EVENT OF CONFLICT, THE MOST STRINGENT REQUIREMENTS SHALL APPLY. -- \ B14 APPLICANT: PROPERTY OWNER: (LANDLORD) - 15. ALL DIMENSIONS & EXISTING CONDITIONS SHALL BE CHECKED AND VERIFIED BY THE APPLE, INC. SWIFT RESULTS WAY LLC CONTRACTOR AT THE SITE PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. ONE APPLE PARK WAY, M/S 52-RD c/o SWIFT REAL ESTATE PARTNERS u CUPERTINO, CA 95014 260 CALIFORNIA ST, SUITE 1100 - 16. ALL EXISTING CONSTRUCTION SHALL BE PROTECTED FROM DAMAGE THROUGHOUT THE PHONE: 917-297-5028 SAN FRANCISCO, CA 94111-4300 - * \ \ = X PERIOD OF CONSTRUCTION WORK. ANY DAMAGED CONSTRUCTION OR FEATURES SHALL CONTACT: ROBERTO BOTELHO PHONE: 408-307-3956 Apple Inc. i ICE I �� �� �- BE REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE SATISFACTION TO THE EMAIL: RBOTELHO@APPLE.COM CONTACT: NATE CARLSON - - 1 Apple Park Way OWNER WITH MATERIALS EQUIVALENT OR SUPERIOR TO THE ORIGINAL ITEM(S). CONTACT: REBECCA TOLENTINO EMAIL: CARLSON@SWIFTRP.COM r l ICI J B 1 5 - - ,, ;�� 17. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL DIMENSIONS EMAIL: REBECCA_TOLENTINO@APPLE.COM ' 2J MS 52-RD AND INSPECT CONDITIONS OF PRIOR WORK OF THE OTHER TRADES BEFORE STARTING Cupertino, CA WORK. PROCEEDING WITH WORK SHALL CONSTITUTE ACCEPTANCE OF PRIOR WORK. ARCHITECT: SCAFFOLDING ENGINEER: �I f' c =\ 95014 BOHLIN CYWINSKI JACKSON SCAFFOLD ENGINEERING, INC _ �C3 °� 18. DETAILS ARE USUALLY KEYED AND NOTED "TYPICAL" ONLY ONCE, WHEN THEY FIRST 49 GEARY STREET, SUITE 300 401 SOUTH SEGUIN ROAD v _ --_ - 1 OCCUR, AND ARE REPRESENTATIVE OF SIMILAR CONDITIONS THROUGHOUT, UNLESS SAN FRANCISCO, CA 94108 CONVERSE, TX 78109 - Architect: PHONE: 415-989-2100 PHONE: 830-609-9113 - ;=\ Bohlin Cywinski Jackson 19. SUITABLE MEASURES SHALL BE TAKEN TO PREVENT INTERACTION BETWEEN DISSIMILAR FAX: 415-989-2101 FAX: 775-822-6462 ` - = METALS. CONTACT: STEVE CHAITOW CONTACT: EDWARD FOSTER 1. -' www.bcj.com EMAIL: SCHAITOW@BCJ.COM EMAIL: ED@SCAFFENGINEERING.COM 20. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S PROJECT SITE --' - _ El INSTRUCTIONS. L--- ;" ` CU ERT NOS CA12 RESULT A 95014 � , - - GENERAL CONTRACTOR: P(Res) 21. IN ALL CASES WHERE WORK DEPICTED IN THESE DRAWINGS REPRESENTS A COMPLETE PLANT CONSTRUCTION COMPANY _ SYSTEM COMPOSED OF SEPARATE PARTS, IT IS THE RESPONSIBILITY OF THE GENERAL P( Res) CONTRACTOR TO PROVIDE ALL PARTS, COMPONENTS, 300 NEWHALL ST. _ ACCESSORIES, HARDWARE T ,, I I SANFRANCISCO, CA 94124 rYl Q ve FASTENERS, ETC. REQUIRED FOR A COMPLETE AND FULLY FUNCTIONING ASSEMBLY ` �.S�I - � . 7 PHONE: 530-383-4812 � -_I WITHIN THE DEFINITIONS OF NORMAL INDUSTRY STANDARDS, WHETHER OR NOT THESES - CONTACT: WHITNEY REESE I r 1 0 MISCELLANEOUS ITEMS ARE DIRECTLY SPECIFIED IN THE CONSTRUCTION DOCUMENTS. EMAIL: WHITNEYR@PLANTCO.COM � �! ► 1 � �� � � 30. THE ARCHITECT HAS NO KNOWLEDGE OF AND SHALL NOT BE HELD LIABLE FOR ANY \ f ASBESTOS OR OTHER HAZARDOUS MATERIALS ON THE JOBSITE. IF ASBESTOS OR --I - OTHER HAZARDOUS MATERIALS ARE DISCOVERED DURING CONSTRUCTION, ISOLATE THE \ _ AFFECTED AREA AND CONTACT THE OWNER FOR FURTHER INSTRUCTION BEFORE •� \ -- -- y-; �` PROCEEDING. live A a) _ 31. PROVIDE AND MAINTAIN BARRICADES, LIGHTING, AND GUARDRAILS AS REQUIRED BY M \ 1 - -- � Temporary Skylight Mockup APPLICABLE CODES AND REGULATIONS TO PREVENT ACCESS TO THE MOCKUP EXCEPT BY AUTHORIZED PERSONNEL ML =rc -_ --- -- �- ;�.� 12 Results Way E I' V Cupertino, CA 95014 Issued/Revised Date a r Ave _ T V -� Temporary Use Permit 10/04/21 - - AREA MAP �ICINTY PLAN 12 JEST SITE J B4 - '' ' P1Permit Corrections- Rev 1 11/03/21 PROJECT SITE 12 RESULTS WAY CUPERTINO, CA 95014 \on B3 _M SUNNYVALE 9 1 0 _ . ._ 1■ i ° ,. n os s xeas v r�•S SANTA CLARA LU FrT ... •.... _ U LSE a r I Co -J l a u a uxo > c ° .,- ea<x erry Farm . amlta ve m 6 i a r r ".l aimtv r ,x... ._.�,. � M L 1 i I I I II I I II I I I I II I II III III III_i � I I I III III , I I 0 ,e Apple Approval Date y 1(CG) Al" ��. . aa.00. �" � ` � � �1 I 'a f- MCLELLAN RD GF� ra m, w ti P(R3) GENERAL INFORMATION - A RESU ZONING PLAN SITE PLAN S L Y yam .°°I•"°°— — NOT TO SCALE 1"=100'-0" A-001 Community Development Department Planni g Division — Cupertino CUPERTINO APPROVED Case # I U P-2021-003 Ap licatim Number(s) Approval Body: Director/ Staff Approva I Date 0 /06/22 Signature Jeffre Tsumura Case Manager CITY OF CUPERTINO TREE PROTECTION REQUIREMENTS: 1. Prior to any construction operations contractor shall construct and maintain, for each protected tree on a construction site, protective fencing which encircles the outer limits of the Tree Protection Zone (TPZ). The TPZ is calculated to be a radius of 6 times the diameter of the tree's trunk measured 4.5 feet above the natural grade, or as otherwise approved by the Director of Public Works. Apple Inc. 2. All protective fencing shall be in place prior to commencement of any site work and remain in place until 1 Apple Park Way all exterior construction activity at the site has been completed. MS 52-RD 3. Protective fencing shall be at least four (4) feet high, clearly visible, affixed to 2 inch galvanized posts Cupertino, CA driven into the ground no less than 8' on center, and shall have a tree protection sign affixed to the fence 95014 every twenty (20) feet in such a manner to be clearly visible and legible to workers on the site at a Notes: distance of twenty-five 25 feet. The sign(s) shall read "Kee Out Tree Protection Zone". Tree Protection Area shall be 6 times the DBH of the tree y ( ) p in all directions from the face of the trunk. 1- See Tree Protection Requirements Architect: 4. Install a 5-inch layer of mulch within the TPZ to aid in retaining moisture (Detail 6-2) for additional tree protection Bohlin Cywinski Jackson requirements. 5. Trees shall be kept well watered, especially during dry summer months. A long, slow soak over the www.hcj.com entire root zone is the preferred method of watering. Frequent, shallow watering should be avoided, and 2- If there is no existing irrigation, see water should not be directed at or near the trunks of trees. Tree Protection Requirements for 6. The Contractor shall cause the required fencing and signage to be installed and maintained for the watering requirements. duration of the construction. 3- No pruning shall be performed except 7. In situations where a protected tree remains in the immediate area of intended construction and the tree by an approved arborist. may be in danger of being damaged by construction equipment or other activity, the contractor or subcontractor shall protect the tree with 2"x4" lumber encircled with wire or other means that do not 4- No equipment shall operate inside the damage the tree. The intent is to protect the trunk of the tree against incidental contact by large protective fencing including during fence construction equipment. installation and removal. 8. Material Storage: No storage or placement of materials intended for use in construction or waste 5- Any modification must be approved by materials accumulated due to excavation or demolition shall be placed within the limits of the TPZ of any the Director of Public Works. protected tree. Tree Protection Temporary Skylight Mockup 9. Equipment Cleaning/Liquid Disposal: No equipment shall be cleaned or other liquids, including, without fence: 4' High, 12 Results Way limitation, paint, oil, solvents, asphalt, concrete, mortar or similar materials shall be deposited or allowed clearly visible, Cupertino, CA 95014 to flow into the TPZ of a protected tree. mounted on steel posts installed at 8' 10. Tree Attachments: No signs, wires or other attachments, other than those of a protective nature, shall f on center. be attached to any protected tree. 8.5" x 11" �l 2" x 6' steel posts 11. Vehicular Traffic: No vehicular and/or construction equipment traffic or parking shall take place within laminate sign n or approved equal the TPZ of any protected tree other than on existing street pavement. plastic. in driven into the 12. No heavy equipment, including but not limited to trucks, tractors, trailers, bulldozers, excavators, skid minimum of one ground. Issued/Revised Date steer tractors, trenchers, compressors, and hoists, shall be allowed inside the TPZ of any protected tree sign for each KEEP OUT Temporary Use Permit 10/04/21 on any construction site. facing direction of _ TREE 5" thick P, Permit Corrections Rev 1 11/03/21 the fence. i PROTECTION layer of mulch. 13. Grade Changes: No grade changes shall be allowed within the limits of the TPZ of any protected tree AREA unless adequate protective construction methods are approved in advance in writing by the city. _i.�I� , ; 1, , �,,�� �; �'�!�;�!�;��;\�;� ' Maintain existing 14. Impervious Paving: No paving with asphalt, concrete or other impervious materials shall be placed I r grade with the tree - within the limits of the TPZ of a protected tree. °�; �� �� �-- � ` ii `� q - - protection fence unless otherwise 15. Root Pruning: Any roots two inches or larger in diameter which are exposed as a result of trenching or approved by the other excavation and which are permitted to be cut shall be cut off square with a sharp medium tooth city. saw and covered with natural fiber burlap within two hours of initial exposure. 16. All public sidewalks shall remain open, free and clear for public access, unless closure is permitted by Apple Approval Date the Public Works Department. City of Cupertino Approved B ?—+-- Date 5/27/2020 _ TREE PROTECTION CITY OF CUPERTINO APPROVED BY: �z—_ DATE: �/27/2020 6-2 Standard Detail pp y 6 4 DETAILS STANDARD DETAILS ( , y E Il gineer City Engineer A-002 Community Development Department Planni g Division — Cupertino 1 M X 2M GLAZING MOCKUP PANEL, CUPERTINO APPROVED TYP OF 8 Case # UP-2021-003 Ap Aication Number(s) I I Approval Body: Director/ Staff Approva I Date 0 /06/22 Signature Jeffre Tsumura Case Manager I I SCAFFOLDING TRUSS, TYP. i/ i/ iii i/r // i//i/r/ // i// /r/ji/ji / //jiii i/ji jij iii/ iz AS PER SCAFFOLDING ENG. , 4 X 8 PANELS, PAINTED GRAY, BEYOND CLAMP RUBBER PADS GLASS PANEL N .......... ............................................. ......................................................... .......... ............................................ SCAFFOLDING 0 DESIGNED BY LICENSED ENGINEER i i� ....................................................... ....................................................... ...................................................... ...................................................... ................ .................................. ..................................................... : I : SCRIM BEYOND :I SCAFFOLD BEAM ELEVATION GLASS ATTACHMENT DETAIL 3 1/4„-1'—O" 3"=1'-0" Apple Inc. 30,-0" 01 1 Apple Park Way MS 52-RD 10'-0" 10'-0" 10'-0" Cupertino, CA 95014 TRANSLUCENT SCRIM AROUND SCAFFOLD, (DASHED LINE DESCRIBES EXTENT) Architect: Bohlin Cywinski Jackson www.bcj.com i� OPEN TO PAVING // \ / 1 M X 2M GLAZING MOCKUP PANEL, v / SURFACE I BELOW, TYP. / v /\ / \ / \ / I SCAFFOLDING TRUSS, TYP OF 8 AS PER SCAFFOLDING ENGINEER CD SCAFFOLDING BELOW, SEE SCAFFOLD DRAWINGS 1 M X 2M GLAZING MOCKUP PANEL, TYP OF 8 I I I I I I I - 4 SCAFFOLDING TRUSS, - Temporary Skylight Mocku AS PER SCAFFOLD ENGINEER p Yp A--� ' F ? 12 Results Wa i i _ Y T_ CT N N 4 X 8 PANELS, PAINTED GRAY Cupertino, CA 95014 �.::'.'.'.::' i / co N I CL OF SCAFFOLD SCAFFOLDING, \ / \ / \ / POSTS, TYP. i AS DESIGNED BY LICENSED ENGINEER Issued/Revised Date CD Temporary Use Permit 10/04/21 V. ti / \ / OPEN TO PAVING \ / \ / \ / SURFACE BELOW TYP. \ / \ :r r : : :::::.: ........................... . ......... .......................... .......................... . ............ . ............. . ....Ji ..................... SCRIM OVER SCAFFOLD, BLACK F 1:::::::::::::::..... ::':.: t 5'-10 3/4" Apple Approval Date 3 PLANS, ELEVS, & DETAILS P LAN ELEVATION 1 1/47)=1 1-0" 2 1/4114-0)) A- 1 00