Loading...
HomeMy WebLinkAbout21-182 Encroachment Agreement, GTE Mobilnet of California Limited Partnership, dba Verizon Wireless, R.O.W, 20975 Valley Green DriveCupertino_Cuper020 / 417714 ENCROACHMENT AGREEMENT This Encroachment Agreement ("Encroachment Agreement"), made this day of , 20_ ("Effective Date") between the City of Cupertino, a political subdivision of the State of California, hereinafter designated "Licensor" and GTE Mobilnet of California Limited Partnership, d/b/a Verizon Wireless, with its principal offices at c/o Verizon Wireless, 180 Washington Valley Road, Bedminster, New Jersey 07921, hereinafter designated "Licensee": 1. Encroachment Agreement. This is an Encroachment Agreement as referenced in that certain Small Cell License Agreement between Licensor and Licensee dated May 16, 2017 ("Agreement"). This Encroachment Agreement shall serve as an encroachment license. All of the terms and conditions of the Agreement are incorporated hereby by reference and made a part hereof without the necessity of repeating or attaching the Agreement. In the event of a contradiction, modification or inconsistency between the terms of the Agreement and this Encroachment Agreement, the terms of the Encroachment Agreement shall govern. Capitalized terms used in this Encroachment Agreement shall have the same meaning described for them in the Agreement unless otherwise indicated herein. 2 Project Description and Locations. Licensee shall have the right to use the ROW for a Small Cell at the designated areas in the ROW as further described in Attachment 1 attached hereto (the "Licensed Area"). 3. Equipment. The Small Cell to be installed at the Licensed Area is described in Attachment 1 attached hereto. 4. Term. The term of this Encroachment Agreement shall be as set forth in Section 2 of the Agreement. 5. Fees. The initial annual Rent for the term of this Encroachment Agreement shall be Three Hundred Dollars ($300) and paid in accordance with Paragraph 5.1 of the Agreement, as amended by Section 4, to that certain Settlement Agreement and Mutual Release entered into between Licensor and Licensee dated October 4, 2017, and as adjusted by Paragraph 5.2 of the Agreement. 6. Commencement Date. The first day of the month following the date Licensee has Commenced Installation of its Equipment at the Licensed Area. 7. Approvals/Fiber. It is understood and agreed that Licensee's ability to use the Licensed Area is contingent upon its obtaining all of the certificates, permits and other approvals (collectively the "Governmental Approvals") that may be required by any Federal, State or Local authorities, as well as a satisfactory fiber and electrical connection which will permit Licensee use of the Licensed Area as set forth above. In the event that (i) any of such applications for such Governmental Approvals should be finally rejected; (ii) any Governmental Approval issued to Licensee is canceled, expires, lapses, or is otherwise withdrawn or terminated by governmental authority; (iii) Licensee determines that such Governmental Approvals may not be obtained in a timely manner; (iv) Licensee determines. that it will be unable to obtain in a satisfactory manner, or maintain any fiber or power connection; or (v) Licensee determines that the Licensed Area is no longer technically compatible for its use, Licensee shall have the right to terminate this Encroachment Agreement. Notice of Licensee's exercise of its right to terminate shall be given to Licensee in writing by certified mail, return receipt requested, and shall be effective upon the mailing of such notice by Licensee, or upon such later date as designated by Licensee. All rentals paid to said termination date shall be retained by Licensor. Upon such termination, this Encroachment Agreement shall be of no further force or effect except to the extent of the representations, warranties and indemnities made by each parry to the other hereunder. Otherwise, Licensee shall have no further obligations for the payment of Rent to Licensor. & Miscellaneous. N/A [Signature page follows] EXECUTED to be effective as of the date shown above. LICENSOR: City of Cupertino, apolitical subdivision of the State of California By: � f— Nanthad Mosley _ Title: City Enfineer ATTEST: Kirsten Squarcia City Clerk Dec 8, 2020 APPROVED AS TO FORM CITY ATTORNEY' S OFFICE BY: flee mor M. Miruze� Print NameHeat er M. Minner City Attorney LICENSEE: GTE MOBILNET OF CALIFORNIA LIMITED PARTNERSHIP, DB/A VERIZON WIRELESS by Cellco Partnership, its General Partner By: ' Cc J-- w A I l f Zq z� Name: Scott Stewart Title: Director Network Exhibits: Attachment 1 Attachment 1 Licensed Area See attached. APPLICANT: VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 CONTACT: CHRIS MOLLER PHONE: (925) 339.2778 EMAIL: CHRIS.MOLLER@VERIZONWIRELESS.COM SITE ACQUISITION: MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 PHONE: (415) 989.1102 EMAIL: VERIZONPOLYGONTEAM@MODUS-CORP.COM LAND USE PLANNER: MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 PHONE: (415) 989.1102 EMAIL: VERIZONPOLYGONTEAM@MODUS-CORP.COM E Ir 1:;r. PROJECT TEAM MODUS PROJECT MANAGER: MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 PHONE: (415) 989.1102 EMAIL: VERIZONPOLYGONTEAM@MODUS-CORP.COM A&E PROJECT MANAGER: MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 PHONE: (415) 989.1102 EMAIL: VERIZONPOLYGONTEAM@MODUS-CORP.COM CONSTRUCTION/IMPLEMENTATION MANAGER: MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 PHONE: (415) 989.1102 EMAIL: VERIZONPOLYGONTEAM@MODUS-CORP.COM CUPERTINO CUPER020 (NEAR) 20975 VALLEY GREEN DR CUPERTINO, CA 95014 SITE ID: CUPERTINO CUPER020 SITE TYPE: LIGHT POLE POLE # : 5800 COUNTY: SANTA CLARA PSLC: 417714 PROJECT DESCRIPTION VERIZON WIRELESS PROPOSES TO INSTALL A NEW WIRELESS COMMUNICATION SITE ON A LIGHT POLE IN THE PUBLIC RIGHT-OF-WAY. SCOPE: • INSTALL (1) NEW CANISTER ANTENNA INSIDE NEW FRP CONCEALMENT SHROUD ON TOP OF POLE • INSTALL (2) 5G ANTENNA/RADIOS • INSTALL (2) RRUS-32 RADIOS • INSTALL (2) PSU-AC08 BEHIND RADIOS • INSTALL NEW COAX FROM EQUIPMENT TO NEW ANTENNA WITHIN POLE • INSTALL (1) NEW SMART METER / DISCONNECT ON SIDE OF POLE • INSTALL NEW POLE AND FOUNDATION TO REPLACE EXISTING VICINITY MAP Homestead Park AparinnentS r $ Kirkland Or .111 Crunch Fitness Sunnyvale Village Square Kodiak Cl villa 1 r Jin Li Yuan Apartments ro Louise Dr O La GF8ndl- Dr Forge Homestead Apartments 7-Eleven McDonald's Tea Era YAY01 Cupertino � Rite Al z a Taiwan Porridge a. @ Kingdom 4 Q _ a Safeway Village Green Apartments + The Markham Q � Apartments Valley Church � CulJi i Is z .—... 20975 VALLEY 0 SITE GREEN DRIVE Public Storage raidena X Villages at Cupertino Apartment Homes 9 •z T1 Dr Garden Gate Elementary School Gr•enl•*l pr lr A rr Gr ° d Or d cracntdnlOr ro � Grenola Dr' C Kinderland Child 0 Development Center Laurvtta Dr Garden Gale Or valley C Apple Fitness Center 9 W A"(�* Q Apple 9 Oun4er Dr Fd9o0 m N 4 µ rclord nr SITE INFORMATION SITE ADDRESS: OWNER: APPLICANT: LATITUDE: LONGITUDE: COUNTY: ASSESSORS PARCEL NUMBER ZONING: ELEVATION: (NEAR) 20975 VALLEY GREEN DR CUPERTINO, CA 95014 CITY OF CUPERTINO 10300 TORRE AVE CUPERTINO, CA 95014 VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 37.33321 NAD83 -122.0414 NAD83 SANTA CLARA PUBLIC RIGHT OF WAY NEAR 326-09-041 CITY OF CUPERTINO 238.83' AMSL / o CALL 811 BEFORE YOU DIG IT'S THE LAW THE UTILITIES SHOWN HEREIN ARE FOR THE CONTRACTORS CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THE ENGINEER/SURVEYOR ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL THE UTILITIES WITHIN THE LIMITS OF THE WORK. ALL DAMAGE MADE TO THE (E) UTILITIES BY THE CONTRACTOR SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. DRAWING INDEX SHEET NO. SHEET TITLE T-1 TITLE SHEET T-2 GENERAL NOTES C-1 SURVEY A-1 SITE PLAN & ENLARGED SITE PLAN A-2 ELEVATIONS A-3 ELEVATIONS A-4 CIRCUIT DIAGRAM D-1 DETAILS D-2 DETAILS D-3 POLE SPECS D-4 CITY STANDARD DETAILS E-1 ELECTRICAL GENERAL NOTES E-2 ONE -LINE DIAGRAM & GROUNDING SCHEMATIC E-3 ELECTRICAL DETAILS CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES. • 2019 CALIFORNIA CODE • 2019 CALIFORNIA BUILDING CODE (CBC), BASED ON THE 2018 IBC • 2019 CALIFORNIA RESIDENTIAL CODE (CRC), BASED ON THE 2018 IRC • 2019 CALIFORNIA ELECTRICAL CODE (CEC), BASED ON THE 2017 NEC • 2019 CALIFORNIA MECHANICAL CODE (CMC), BASED ON THE 2018 UMC • 2019 CALIFORNIA PLUMBING CODE (CPC), BASED ON THE 2018 UPC • 2019 CALIFORNIA GREEN BUILDINGS STANDARDS CODE (CALGREEN) • 2019 CALIFORNIA FIRE CODES WITH ALL LOCAL AMENDMENTS • ANY LOCAL BUILDING CODE AMENDMENTS TO THE ABOVE • CITY / COUNTY ORDINANCES ACCESSIBILITY REQUIREMENTS FOR PERSONS WITH DISABILITIES: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. ACCESSIBILITY IS NOT REQUIRED IN ACCORDANCE WITH CALIFORNIA ADMINISTRATIVE STATE CODE PART 2, TITLE 24, CHAPTER 11 B, SECTION 1 103B. verizonN/ VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 DRAWN BY: APE CHECKED BY: BPM �A�PPROVEDBY: LJB REV DATE DESCRIPTION 0 04/03/20 100% CD 1 06/24/20 100% CD REV 1 2 10/29/20 100% CD PLAN CHECK 'eRp�ESS/0. f = � ` Ln * NO. C64533 CIVIL���_= Or IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT CUPERTINO_CUPER020 (NEAR) 20975 VALLEY GREEN DR CUPERTINO, CA 95014 TITLE SHEET T-1 GENERAL NOTES GENERAL CONSTRUCTION NOTES 1. PLANS ARE INTENDED TO BE DIAGRAMMATIC ONLY, UNLESS NOTED OTHERWISE. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 2. THE CONTRACTOR SHALL OBTAIN, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. 3. CONTRACTOR SHALL CONTACT USA (UNDERGROUND SERVICE ALERT) AT (800) 227-2600, FOR UTILITY LOCATIONS, 2 WORKING DAYS BEFORE PROCEEDING WITH ANY EXCAVATION, SITE WORK OR CONSTRUCTION. 4. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OTHERWISE, OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 5. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CBC'S REQUIREMENTS REGARDING EARTHQUAKE RESISTANCE, FOR, BUT NOT LIMITED TO, PIPING, LIGHT FIXTURES, CEILING GRID, INTERIOR PARTITIONS, AND MECHANICAL EQUIPMENT. ALL WORK MUST COMPLY WITH LOCAL EARTHQUAKE CODES AND REGULATIONS. 6. REPRESENTATIONS OF TRUE NORTH, OTHER THAN THOSE FOUND ON THE PLOT OF SURVEY DRAWINGS, SHALL NOT BE USED TO IDENTIFY OR ESTABLISH BEARING OF TRUE NORTH AT THE SITE. THE CONTRACTOR SHALL RELY SOLELY ON THE PLOT OF SURVEY DRAWING AND ANY SURVEYOR'S MARKINGS AT THE SITE FOR THE ESTABLISHMENT OF TRUE NORTH, AND SHALL NOTIFY THE ARCHITECT / ENGINEER PRIOR TO PROCEEDING WITH THE WORK IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND THE TRUE NORTH ORIENTATION AS DEPICTED ON THE CIVIL SURVEY. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE TO NOTIFY THE ARCHITECT / ENGINEER. 7. THE BUILDING DEPARTMENT ISSUING THE PERMITS SHALL BE NOTIFIED AT LEAST TWO WORKING DAYS PRIOR TO THE COMMENCEMENT OF WORK, OR AS OTHERWISE STIPULATED BY THE CODE ENFORCEMENT OFFICIAL HAVING JURISDICTION. 8. DO NOT EXCAVATE OR DISTURB BEYOND THE PROPERTY LINES OR LEASE AREA LINES, UNLESS OTHERWISE NOTED. 9. ALL EXISTING UTILITIES, FACILITIES, CONDITIONS, AND THEIR DIMENSIONS SHOWN ON THE PLAN HAVE BEEN PLOTTED FROM AVAILABLE RECORDS. THE ARCHITECT / ENGINEER AND THE OWNER ASSUME NO RESPONSIBILITY WHATSOEVER AS TO THE SUFFICIENCY OR THE ACCURACY OF THE INFORMATION SHOWN ON THE PLANS, OR THE MANNER OF THEIR REMOVAL OR ADJUSTMENT. CONTRACTORS SHALL BE RESPONSIBLE FOR DETERMINING EXACT LOCATION OF ALL EXISTING UTILITIES AND FACILITIES PRIOR TO START OF CONSTRUCTION. CONTRACTORS SHALL ALSO OBTAIN FROM EACH UTILITY COMPANY DETAILED INFORMATION RELATIVE TO WORKING SCHEDULES AND METHODS OF REMOVING OR ADJUSTING EXISTING UTILITIES. 10. CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES, BOTH HORIZONTAL AND VERTICALLY, PRIOR TO THE START OF CONSTRUCTION. ANY DISCREPANCIES OR DOUBTS AS TO THE INTERPRETATION OF PLANS SHOULD BE IMMEDIATELY REPORTED TO THE ARCHITECT / ENGINEER FOR RESOLUTION AND INSTRUCTION, AND NO FURTHER WORK SHALL BE PERFORMED UNTIL THE DISCREPANCY IS CHECKED AND CORRECTED BY THE ARCHITECT / ENGINEER. FAILURE TO SECURE SUCH INSTRUCTION MEANS CONTRACTOR WILL HAVE WORKED AT HIS/HER OWN RISK AND EXPENSE. 11. ALL NEW AND EXISTING UTILITY STRUCTURES ON SITE AND IN AREAS TO BE DISTURBED BY CONSTRUCTION SHALL BE ADJUSTED TO FINISH ELEVATIONS PRIOR TO FINAL INSPECTION OF WORK. 12. ANY EXISTING COMPONENTS DISTURBED DURING CONSTRUCTION SHALL BE RETURNED TO IT'S ORIGINAL CONDITION PRIOR TO COMPLETION OF WORK. SIZE, LOCATION AND TYPE OF ANY UNDERGROUND UTILITIES OR IMPROVEMENTS SHALL BE ACCURATELY NOTED AND PLACED ON "AS -BUILT" DRAWINGS BY GENERAL CONTRACTOR, AND ISSUED TO THE ARCHITECT / ENGINEER AT COMPLETION OF PROJECT. 13. ALL TEMPORARY EXCAVATIONS FOR THE INSTALLATION OF FOUNDATIONS, UTILITIES, ETC., SHALL BE PROPERLY LAID BACK OR BRACED IN ACCORDANCE WITH CORRECT OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) REQUIREMENTS. 1. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CONTRACTOR. 2. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS MUST BE VERIFIED. CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 3. THE EXISTING CELL SITE IS IN FULL COMMERCIAL OPERATION. ANY CONSTRUCTION WORK BY CONTRACTOR SHALL NOT DISRUPT THE EXISTING NORMAL OPERATION. ANY WORK ON EXISTING EQUIPMENT MUST BE COORDINATED WITH CONTRACTOR. ALSO, WORK SHOULD BE SCHEDULED FOR AN APPROPRIATE MAINTENANCE WINDOW USUALLY IN LOW TRAFFIC PERIODS AFTER MIDNIGHT. 4. SINCE THE CELL SITE IS ACTIVE, ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN WORKING AROUND HIGH LEVELS OF ELECTROMAGNETIC RADIATION. EQUIPMENT SHOULD BE SHUTDOWN PRIOR TO PERFORMING ANY WORK THAT COULD EXPOSE THE WORKERS TO DANGER. PERSONAL RF EXPOSURE MONITORS ARE ADVISED TO BE WORN TO ALERT OF ANY DANGEROUS EXPOSURE LEVELS. 5. CONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWING. CONTRACTOR SHALL UTILIZE EXISTING TRAYS AND/OR SHALL ADD (N) TRAYS AS NECESSARY. CONTRACTOR SHALL CONFIRM THE ACTUAL ROUTING WITH THE CONTRACTOR. 6. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. APPLICABLE CODES, REGULATIONS AND STANDARDS: 1. CONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. 2. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE TIME OF PERMITTING AWARD SHALL GOVERN THE DESIGN. 3. CONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING STANDARDS: 3.1. - AMERICAN CONCRETE INSTITUTE (ACI) 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 3.2. - AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, ASD, NINTH EDITION 3.3. - TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 222-F, STRUCTURAL STANDARD FOR STRUCTURAL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES 3.4. - INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING EARTH RESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND SYSTEM IEEE 1 100 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OF ELECTRICAL EQUIPMENT. 3.5. -IEEE C62.41, RECOMMENDED PRACTICES ON SURGE VOLTAGES IN LOW VOLTAGE AC POWER CIRCUITS (FOR LOCATION CATEGORY 'C3" AND "HIGH SYSTEM EXPOSURE") 4. TIA 607 COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS 4.1. TELCORDIA GR-63 NETWORK EQUIPMENT -BUILDING SYSTEM (NEBS): PHYSICAL PROTECTION 4.2. TELCORDIA GR-347 CENTRAL OFFICE POWER WIRING 4.3. TELCORDIA GR-1275 GENERAL INSTALLATION REQUIREMENTS 4.4. TELCORDIA GR-1503 COAXIAL CABLE CONNECTIONS 5. ANY AND ALL OTHER LOCAL & STATE LAWS AND REGULATIONS 6. FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING MATERIAL, METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN. GENERAL TRENCHING NOTES 1. MAINTAIN 24" MINIMUM COVER FOR ALL ELECTRICAL CONDUITS, U.O.N. 2. MAINTAIN 30" MINIMUM COVER FOR ALL TELECOMMUNICATIONS CONDUITS. 3. MINIMUM 1" SAND SHADING BELOW CONDUITS, AND 6" COVERING ON TOP OF CONDUITS REQUIRED. 4. REFER TO SHEET E-1 FOR ADDITIONAL REQUIREMENTS GENERAL GROUNDING NOTES 1. GROUNDING SHALL BE TESTED AT 5 OHMS OR LESS. 2. WOOD MOLDING, STAPLED EVERY 3'-0" AND AT EACH END. GENERAL CONDUIT NOTES 1. ALL CONDUITS WILL BE MANDRELED AND EQUIPPED WITH 3/8" PULL ROPE. 2. SCHEDULE 40 CONDUIT FOR UNDERGROUND USE. 3. SCHEDULE 80 CONDUIT FOR RISER USE AND ELSEWHERE AS NOTES. TRANSITION FROM SCHEDULE 40 PVC OR RIGID STEEL CONDUIT TO SCHEDULE 80 USING APPROVED FITTINGS DESIGNED TO PROVIDE A SMOOTH INTERIOR WALL TRANSITION TO THE REDUCED INTERIOR DIAMETER OF SCHEDULE 80. ADJUST CONDUIT SIZE IF NECESSARY TO MAINTAIN THE INTERIOR AREA REQUIRED FOR THE WIRING SPECIFIED. 4. GALVANIZED STEEL CONDUIT FOR ANY CONDUIT UNDER 3", STUB UP 10" THEN CONVERT TO SCHEDULE 80. 5. CONTRACTOR TO STUB UP POLE 10" w/ 3" POWER CONDUIT. POWER COMPANY TO CONVERT FROM 3" STUB SCHEDULE 80 TO 2" SCHEDULE 80 FROM TOP OF STUB UP. 6. ZRC COLD GALVANIZING COMPOUND OR EQUIVALENT IS REQUIRED ON EXPOSED THREADS IN RIGID STEEL CONDUIT AND THE CUT ENDS OF SUPPORT STRUTS, ETC. TO PREVENT RUSTING. TYPICAL R.O.W. POLE CONSTRUCTION NOTES 1. CABLE NOT TO IMPEDE 15" CLEAR SPACE OFF POLE FACE. 2. ALL CLIMB STEPS NEXT TO CONDUIT SHALL HAVE EXTENDED STEPS. 3. NO BOLT THREADS TO PROTRUDE MORE THAN 1-1/2" 4. ALL HOLES IN POLE LEFT FROM REARRANGEMENT OF CLIMB STEPS TO BE FILLED 5. 900 SHORT SWEEPS UNDER ANTENNA ARM, ALL CABLES MUST TRANSITION ON THE INSIDE OR BOTTOM OF THE ARM (NO CABLE ON TOP OF ARM). 6. USE 900 CONNECTOR AT CABLE CONNECTION FOR OMNI DOWN ANTENNAS. 7. USE CABLE CLAMPS TO SECURE CABLE TO ARMS, PLACE 2" CABLE I.D. TAGS ON BOTH SIDES OF ARMS. 8. USE 1/2" DIA. CABLE ON ANTENNAS UNLESS OTHERWISE SPECIFIED. 9. PLACE GPS ON ARM OF SOUTHERN SKY EXPOSURE AT MINIMUM 6" FROM TRANSMIT ANTENNA WHICH IS 24" AWAY FROM CENTER OF POLE. 10. FILL VOID AROUND CABLES AT CONDUIT OPENING WITH FOAM SEALANT TO PREVENT WATER INTRUSION. CONTRACTOR REQUIREMENTS DO NOT SCALE OFF DRAWINGS CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK ABBREVIATIONS A.B. ANCHOR BOLT GLB• GLUE LAMINATED ABV. ABOVE (GLU-LAM) BEAM ACCA ANTENNA CABLE COVER GPS GLOBAL POSITIONING verizonN/ ASSEMBLY SYSTEM ADD'L ADDITIONAL GRND. GROUND A.F.F. ABOVE FINISHED FLOOR HDR. HEADER A.F.G. ABOVE FINISHED GRADE HGR. HANGER AGL ABOVE GROUND LEVEL HT. HEIGHT ALUM ALUMINUM ICGB. ISOLATED COPPER ALT. ALTERNATE GROUND BUS AMSL ABOVE SEA LEVEL IN.(") INCH(ES) VERIZON WIRELESS ANT. ANTENNA INT. INTERIOR APPRX. APPROXIMATE(LY) LB.(#) POUND(s) 2785 MITCHELL DRIVE, SUITE 9 ARCH. ARCHITECTURAL) L.B. LAG BOLTS WALNUT CREEK, CA AWG. AMERICAN WIRE GAUGE L.F. LINEAR FEET(FOOT) BLDG. BUILDING L. LONGITUDINAL 94598 BLK. BLOCK MAS. MASONRY BLKG BLOCKING MAX. MAXIMUM BM. BEAM M.B. MACHINE BOLT B.N. BOUNDARY NAILING MECH. MECHANICAL BN BACK-UP CABINET MFR. MANUFACTURER BTCW. BARE TINNED COPPER WIRE MIN. MINIMUM B.O. BOTTOM MISC. MISCELLANEOUS B.O.F. BOTTOM OF FOOTING MTL. METAL CAB. CABINET NO. (#) NUMBER CANT. CANTILEVER(ED) N.T.S. NOT TO SCALE C.I.P. CAST IN PLACE (N) NEW CLG. CEILING O.C. ON CENTER fi D U S Q CENTERLINE OPNG. OPENING CLR. CLEAR P/C PRE CAST CONCRETE COL. COLUMN PCs PERSONAL COMMUNICATION CONIC. CONCRETE SERVICES MODUS, LLC CONN. CONNECTION(OR) R PLATE CONST. CONSTRUCTION PLY. PLYWOOD 240 STOCKTON ST., 3RD FLOOR CONT. CONTINUOUS PPC. POWER PROTECTION CABINET d PENNY (NAILS) PRC. PRIMARY FLEXING CABINET SAN FRANCISCO, CA DBL. DOUBLE P.S.F. POUNDS PER SQUARE FOOT 94108 DEPT. DEPARTMENT P.S.I. POUNDS PER SQUARE INCH D.F. DOUGLAS FIR P.T. PRESSURE TREATED DIA. DIAMETER PWR. POWER (CABINET) DIAG. DIAGONAL QTY. QUANTITY DRAWN BY: APE DIM. DIMENSION RAD.(R) RADIUS DWG. DRAWING(S) REF. REFERENCE DWL. DOWEL(S) REINF. REINFORCING CHECKED BY: BPM EA. EACH REQ'D. REQUIRED EL. ELEVATION RGS. RIGID GALVANIZED STEEL �A�PPROVEDBY: LJB ELEC. ELECTRICAL R.O.W. RIGHT OF WAY ELEV. ELEVATOR SCH. SCHEDULE EMT. ELECTRICAL METALLIC SHT. SHEET TUBING Sim. SIMILAR REV DATE DESCRIPTION E.N. EDGE NAIL SPEC. SPECIFICATIONS) 0 04/03/20 100% CD ENG. ENGINEER SQ. SQUARE EQ. EQUAL S.S. STAINLESS STEEL 1 06/24/20 100% CD REV 1 EXP. EXPANSION STD. STANDARD 2 10/29/20 100% CD PLAN CHECK EXST.(E) EXISTING STL. STEEL EXT. EXTERIOR STRUC. STRUCTURAL FAB. FABRICATION(OR) TEMP. TEMPORARY F.F. FINISH FLOOR THK. THICKNESS F.G. FINISH GRADE T.N. TOE NAIL FIN. FINISH(ED) T.O.A. TOP OF ANTENNA FLR. FLOOR T.O.C. TOP OF CURB FDN. FOUNDATION T.O.F. TOP OF FOUNDATION F.O.C. FACE OF CONCRETE T.O.P. TOP OF PLATE(PARAPET) F.O.M. FACE OF MASONRY T.O.S. TOP OF STEEL F.O.S. FACE OF STUD T.O.W. TOP OF WALL F.O.W. FACE OF WALL TYP. TYPICAL F.S. FINISH SURFACE U.G. UNDER GROUND FT.(') FOOT(FEET) U.L. UNDERWRITES LABORATORY FTG. FOOTING U.N.O. UNLESS NOTED OTHERWISE G. GROWTH(CABINET) V.I.F. VERIFY IN FIELD GA. GAUGE W WIDE(WIDTH) GI. GALVANIZE(D) W/ WITH G.F.I. GROUND FAULT CIRCUIT WD. WOOD INTERRUPTER W.P. WEATHERPROOF WT. WEIGHT m-EGEND STEEL GROUT OR PLASTER SPOT ELEVATION (E) BRICK Zx REVISION (E) MASONRY OGRID REFERENCE CONCRETE - - EARTH e-- X DETAIL REFERENCE 0000000000 GRAVEL X ELEVATION X-X REFERENCE PLYWOOD X X-X SECTION REFERENCE SAND MATCH LINE - - - - - CENTERLINE WORK POINT _ _ _ _ _ _ PROPERTY/LEASE LINE GROUND CONDUCTOR T TELEPHONE CONDUIT E ELECTRICAL CONDUIT E/T ELECTRICAL & TELCO CONDUITS A COAXIAL CABLE O/H OVERHEAD SERVICE CONDUCTORS X CHAIN LINK FENCING WOOD FENCING OHT/OHP OVERHEAD TELEPHONE/ OVERHEAD POWER oHT OVERHEAD TELEPHONE OHP OVERHEAD POWER LINE 'QRfl.. ESS... ' NO. C64533 _CIVIL���__ OF C kol IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT CUPERTINO_CUPER020 (NEAR) 20975 VALLEY GREEN DR CUPERTINO, CA 95014 GENERAL NOTES T-2 I I ABBREVIATIONS REF PLAT # BK. 326 - PG. 9 PL PROPERTY LINE RIGHT OF WAY D%W DRIVEWAY SITE ID:CUPERTINO_CUPER_20 (N) NEWTING AGL ABOVE GROUND LEVEL 60, CTR-LINE CENTER LINE I OH OVERHEAD DISCLAIMER: I 40 Y SYMBOLS THE BOUNDARY REPRESENTED ON THIS MAP IS BASED ON COMPILED w a I EASTERLY (9 EXISTING POLE ® WATER VAULT RECORD DATA, GIS LINEWORK AND IS BEST FIT ONTO EXISTING IMPROVEMENTS. IT IS POSSIBLE FOR THE LOCATION OF THE SUBJECT a C) w o RIGHT-OF-WAY OF PULL BOX STREET SIGN OTHERS UTILITY POLE TO SHIFT FROM THE PLACEMENT SHOWN HEREON WITH 1n o v1 N STELLING RD TREE ® MAIL BOX ADDITIONAL FIELD EVIDENCE AND RESEARCH. THEREFORE, ANY Z SHRUB MH MANHOLE SPATIAL REFERENCE MADE OR SHOWN BETWEEN THE BOUNDARY AND EXISTING GROUND FEATURES, EASEMENTS, OR LEASE AREA SHOWN I �w WATER VALVE d FIRE HYDRANT HEREON IS INTENDED TO BE APPROXIMATE AND IS SUBJECT TO 0 0 LARM 6' AT 274.23' —G GUY WIRE STREET LIGHT POLE VERIFICATION BY RESOLVING THE POSITION OF THE BOUNDARY LINES. Uj Zo I EXISTING VALVE HEINLET �. z U w PROPOSED LOCATION OF FACILITIES: o FIBER VAULT L MONUMENT oN-16 BASIS OF BEARINGS HORIZONTAL DATUM ( ) GEODETIC NORTH AS REFERENCED TO THE WORLD GEODETIC SYSTEM w v> J LATITUDE: 37°19'59.526"N LINE TYPES OF 1984("WGS84"), WHICH ON THIS SURVEY, FOR ALL INTENTS AND a w J LONGITUDE: 122°02'28.975"W - - RIGHT OF WAY PURPOSES, IS THE SAME AS THE NORTH AMERICAN DATUM OF I o J U ELEVATION: 238.83' - — — CENTER LINE TOP OF POLE 1983 ("NAD83"). I Q Z ui 6 I O/H OH LINE(S) 30-6 AGL (E) STREET LIGHT BRACKETS o v H� yl STEEL LIGHT POLE 29'-10" AGL I 21'-3"# APN: 10711 I w 7-9 t 326-09-041 BACK N STELLING RD I N OF POLE TO 20975 CUPERTINO, 6„ o Z RIGHT-OF-WAY VALLEY GREEN DR CA 95014 < CUPERTINO, ♦ CA 95014 I- - - - - - - - - - (E) CONCRETE SIDEWALK a LANDSCAPE WESTERLY I FACE OF THE CURB RIGHT-OF-WAY OF ��j E TOP OF STREET SIGN N STELLING RD 12'-6" AGL E BOTTOM OF SIGN 0 11'-7" AGL (E) TOP OF STREET SIGN/` 10'-10" AGL 10697 O (E) BOTTOM OF SIGNS N STELLING RD 9'-11" AGL MEDIAN VALLEY GREEN DR CUPERTINO, — — — — — — CA 95014 CTR-LINE I 0 (E) GRADE FACE OF THE CURB 00 N21 8' I LANDSCAPE (E) CONCRETE SIDEWALK Center pole — — — — — — — — — — Lotitude 37.33321 N Longitude 122.0414 W N NAD83 & WGS84 Z Pole height: 30' 6" J�w J W J J a a W H� w � ~ o w v1 U = w 10683 a w Z ~ a W GRAPHIC SCALE VERTICAL DATUM N STELLING RD o W 0 o� w 25 0 15 30 50 CUPERTINO, Z v w z v THE NORTH AMERICAN VERTICAL DATUM OF 1988 ("NAVD88") I a z Z 20990 CA 95014 IJ o < J of VALLEY GREEN DR w CUPERTINO, (IN FEET) 40'W CA 95014 1 inch = 30ft. 60' Pole ID: 5800 SCALE: 1" = 8' LAND S��G MICHAEL `moo DESIGN BY: PE REV DESCRIPTION DATE DRAWN BY: PE 1. ISSUE OF CONSTRUCTION 02/25/2020 --NG 4746 Clayton Rd, Concord, CA, 94521. CUPERTINO CUPER020 APPROVED:e_® splanneng@gmail.com APPROVED: PIa1 11 1 20975 VALLEY GREEN DR APPROVED: `� www.planneng.com CUPERTINO, CA 95014 STgTF OF CpL\F���\P PLS STAMP NOTE: 1. FIBER PULLBOX EXACT LOCATION TO BE VERIFIED IN FIELD 2. UPON COMPLETION OF CONSTRUCTION, RESTORE LANDSCAPE AND IRRIGATION TO LIKE OR BETTER CONDITION, TEST IRRIGATION 3. UPON COMPLETION OF CONSTRUCTION, NOTIFY THE CITY OF NEW STREETLIGHT INSTALLATION SO THAT NEW BADGE ID NUMBER CAN BE PLACED BY THE CITY ONTO THE NEW STREETLIGHT POLE. (E) FACE OF THE CURB C� z J (E) POLE TO BE REMOVED w — — — — — — — — — — — — — ZI +l 0 co (N) LUMINAIRE (N) STEEL MAST ARM -n W m T W m 70 ENLARGED SITE PLAN J N J N J N a 3 0 Ln w I w U z 0 U �--9"± BACK OF POLE TO ROW LINE- ) (E) POLE FOUNDATION TO BE N REMOVED. OLD BASE TO BE FILLED WITH CONTROLLED DENSITY FILL TO WITHIN 12" OF FINISH GRADE AND CAPPED \ WITH PLANTING SOIL. I J (N) LIGHT POLE (N) LOCATION OF VERIZON \ WIRELESS CANISTER ANTENNA IN FRP \ "' SHROUD MOUNTED ON LIGHT POLE (N) LOCATION OF VERIZON WIRELESS EQUIPMENT MOUNTED ON LIGHT POLE 24"x36" SCALE: 1/2" = l'-0" 11"07" SCALE: 1/4" = 1'-0" w z J w 0 SCALE 2' 1 1 0" 2' 1 /2"=1 '-0" CONDUIT TABLE DESIGNATION CONDUIT BEFORE CONTENTS AFTER CONTENTS (2) #8 STREET LIGHT EXI STI NG 1 1/2" DI A. PVC EC1 CONDUCTORS & (1) #8 BARE N/A (TO BE REMOVED) EQU I PMENT GROU ND (2) #8 STREET LIGHT (2) #8 STREET LIGHT CONDUCTORS & (1) #8 BARE EC2 EXISTING 1 1/2" DI A. PVC CONDUCTORS & (1) #8 BARE EQU I PM ENT GROU ND EQU I PM ENT GROU ND 1 1/2" 2 CELL MAXCELL WITH ONE CELL CONTAINING NEW (2) # 10 THW POW ER & (1) #8 GROU ND. OTHER CELL TO NCI PROPOSED] 1/2" DI A. PVC N/A REMAIN EMPTY, RESERVED FOR FUTURE USE. OUTSIDE OF THE MAXCELL CONTAI NS (2) # 10 EXISTT NG STREET LI GHT CONDU CTORS & (1) #8 BARE EQU I PM ENT GROU ND NC2 PROPOSED 1 1/2" DI A. PVC N/A (4) FO JU M PIERS PROPOSED 2" DIA. CONDUIT NC3 N/A FIBER CABLES (TBD) (UNDER SEPARATE PERMIT) PULL BOX TABLE DESIGNATION DESCRIPTION E1 EXISTING STREET LIGHT PULL BOX w/CARRIER GROUND Ni NEW FI BER PU LLBOX (TO BE LOCATED MI N. 5-0" FROM POLE FOU NDATI ON) (E) FACE OF THE CURB 10711 N STELLING RD CUPERTINO, CA 95014 2 SITE PLAN w Z J w 0- 0 w V Q o _ J w Q V w w J Lu U U Z 0 V) Zw w Q 3 0 w N w Q w Z U Z Z w O 0 w w W w — 1N 2 A-1 GED SITE PLAN (E) STREET SIGN (N) LOCATION OF VERIZON WIRELESS CANISTER ANTENNA AND EQUIPMENT (E) POLE LEGEND R FIBER LINE(S) E ELECTRICAL LINE S/L STREET LIGHT LINE FIBEE A.P.N.: 326-09-041 20975 VALLEY GREEN DR CUPERTINO, CA 95014 (E) CONCRETE SIDWALK (E) LANDSCAPE (E) FACE OF THE CURB VALLEY GREEN DR (E) STREET SIGN (E) MANHOLE (E) MEDIAN 24"x36" SCALE: 1/16" = l'-0" SCALE 11"x17" SCALE: 1/32" = 1'-0" 16' 12' 8' 4' 0" 16' 1/16"=1'-0" N verizonNI VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 m m0DUS MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 DRAWN BY: APE CHECKED BY: BPM APPROVED BY: LJB REV DATE DESCRIPTION 0 04/03/20 100% CD 1 06/24/20 100% CD REV 1 2 10/29/20 100% CD PLAN CHECK 'QRflESSS . ON --j Ln sue- -m NO. C64533 CIVILZ��__ OF. CA\-\FO IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT CUPERTINO_CUPER020 (NEAR) 20975 VALLEY GREEN DR CUPERTINO, CA 95014 SITE PLAN A-1 NOTES: 1. ALL NEW ANTENNAS, BRACKETS, AND OTHER EQUIPMENT WILL BE PAINTED TO MATCH LIGHT POLE. 2. ALL EXISTING SIGNAGE TO BE RELOCATED SHALL BE FASTENED USING STEEL BANDING PER SHEET T-2. 3. INSPECT EXISTING POLE FOR DENTS AND REPLACE POLE AS DIRECTED BY THE CITY 1 CONCEALMENT SHROUD p 1 SHROUOU D verizonN/ T.O. N CONCEALMENT SHROUD 35-6" AGL 4 (N) VERIZON WIRELESS CANISTER ANTENNA D 1 VERIZON WIRELESS RAID CENTER OF N CANISTER ANTENNA 34'-3" AGL 2785 MITCHELL DRIVE, SUITE 9 3 (N) (2) TWIN DIPLEXERS D 1 IN FRP SHROUD WALNUT CREEK, CA 94598 T.O. N LIGHT SENSOR 32'-0" AGL (N) (2) 5G ANTENNAS 6 IN FRP SHROUD D_1 AlIll T.O. E STEEL LIGHT POLE 30'-6" AGL E STEEL LIGHT BRACKET 29'-10" AGL RAID CENTER OF N 5G ANTENNA 31'-7" AGL T.O. N STEEL LIGHT POLE 30'-0" AGL u u 7 (N) LUMINAIRE E-3 aous (!! (E) LUMINAIRE (N) 6'-0" MAST ARM MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 T.O. N NOTICE SIGNAGE 25-2" AGL (N) NOTICE SIGNAGE, TYP. OF (1) 12 FACING STREETSIDE D_1 DRAWN BY: APE CHECKED BY: BPM APPROVED BY: LJB REV DATE DESCRIPTION 0 04/03/20 100% CD 1 06/24/20 100% CD REV 1 2 10/29/20 100% CD PLAN CHECK (N) LIGHT POLE (E) LIGHT POLE TO BE REPLACED (N) (2) RRUS 32s W/ PSU-08 AND 5 8 10 5 CABLE SHROUD D-1 D-1 D-1 E-3 (E) ROAD SIGN T.O. N RADIO UNITS 15-0" AGL (N) RED "BICYCLE 7 9 WRONG WAY" SIGNAGE T.O. N SIGN 14'-8" AGL T.O. E SIGN 12'-6" AGL 1 1'-7" AGL 10'-10" AGLN B.O. E SIGN I I 9'-1 ( AGL (E) ROAD SIGN B.O. N SIGN 13'-2" AGL T.O. E SIGN 12'-6" AGL B.O. N CABLE SHROUD 12'-1" AGL dKB.O. E SIGN 1 V-7' AGL T.O. E SIGN 10'-10" AGL B.O. E SIGN rl (E) ROAD SIGN PORT HOLE LOCATION 1 FOR RRUS D 2 (E) ROAD SIGN QgOFESS/ON"'' 9 ~/ �0 = c = � ' Ln = rrr = crf _ * =: N0. C64533 9�. ,, CIVIL . " 0� OF. C A� 9'-1 1" AGL JK T.O. N DISCONNECT /SMART METER 8'-9" AGL (N) DISCONNECT SMART METER > > 4 3 (ON OPPOSING SIDE) D-1 E-3 E-3 1 � E-3 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT B.O. N DISCONNECT / SMART METER 7-0" AGL PORT HOLE LOCATION 1 Ilk 7-9" BACK OF POLE TO ROW LINE 7-9" BACK OF POLE TO ROW LINE FOR DISCONNECT D 2 CUPERTINO_CUPER020 (NEAR) 20975 VALLEY GREEN DR CUPERTINO, CA 95014 (E) FOUNDATION TO BE REPLACED 4 (N) FOUNDATION D-2 EXISTING & PROPOSED ELEVATIONS EXISTING SURFACE 0'-0" AGL EXISTING SURFACE 0'-0[' AGL A-2 EXISTING ELEVATION 2 PROPOSED ELEVATION 1 1/2"ALo., 1/2"ALo., NOTES: ------------ 1. ALL NEW ANTENNAS, BRACKETS, AND OTHER EQUIPMENT WILL BE PAINTED TO MATCH LIGHT POLE. 2. ALL EXISTING SIGNAGE TO BE RELOCATED SHALL BE FASTENED USING STEEL BANDING PER SHEET T-2. 3. INSPECT EXISTING POLE FOR DENTS AND REPLACE POLE AS DIRECTED BY THE CITY ■ verizonN/ (N) FRP CONCEALMENT 1 SHROUD D 1 T.O. N CONCEALMENT SHROUD 35-6" AGL F= � I I (N) VERIZON WIRELESS 4 VERIZON WIRELESS RAID CENTER OF N CANISTER ANTENNA 34'-3" AGL I CANISTER ANTENNA D_1 2785 MITCHELL DRIVE, SUITE 9 � J (N) (2) TWIN DIPLEXERS 3 IN FRP SHROUD D_1 II� I WALNUT CREEK, CA 94598 (N) LIGHT SENSOR -$T.O. -32'-0" AGL RAD CENTER OF N 5G ANTENNA 31'-7" AGL u U I 7 T.O. E STEEL LIGHT POLE 30'-6" AGL E STEEL LIGHT BRACKET 29'-10" AGL (E) LUMINAIRE T.O. N STEEL LIGHT POLE 30'-0" AGL (N) LUMINAIRE E-3 (N) (2) 5G ANTENNAS IN FRP SHROUD D_1 ! ❑ D U S MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 T.O. N NOTICE SIGNAGE FACING STREETSIDE DRAWN BY: APE 25-2" AGL CHECKED BY: BPM APPROVED BY: LJB REV DATE DESCRIPTION 0 04/03/20 100% CD 1 06/24/20 100% CD REV 1 2 10/29/20 100% CD PLAN CHECK (N) LIGHT POLE (E) LIGHT POLE TO BE REPLACED 5 8 10 5 (N) (2) RRUS 32s W/ PSU-08 AND CABLE SHROUD D-1 D-1 D-1 E-3 T.O. N RADIO UNITS 15-0" AGL T.O. N SIGN 14'-8" AGL o 0 (N) RED "BICYCLE 7 9 WRONG WAY" SIGNAGE T.O. E SIGN 12'-6" AGL rk B.O. E SIGN 1 1'-7" AGL T.O. E SIGN (E) ROAD SIGN B.O. N SIGN 13'-2" AGL T.O. E SIGN 12'-6" AGL B.O. N CABLE SHROUD 12'-1" AGL B.O. E SIGN 1 1'-7" AGL (E) ROAD SIGN PORT HOLE LOCATION 1 FOR RRUS D-2 eRp�ESS/o. . BG�D f `�� _ - � : �r � _ NO. C64533 10'-10" AGL B.O. E SIGN 9'-1 1" AGL (E) ROAD SIGN T.O. E SIGN 10'-10" AGL E SIGN (E) ROAD SIGN . 9 " ,,, CIVIL ,.•` ��_ - �� ...... OF �B.O. 9'-1 1" AGL T.O. N DISCONNECT / SMART METER 8'-9" AGL (N) DISCONNECT SMART METER 1 1 D-1 4 3 1 O E-3 E-3 E-3 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT B.O. N DISCONNECT / SMART METER 7-0" AGL PORT HOLE LOCATION 1 FOR DISCONNECT D-2 CUPERTINO_CUPER020 (NEAR) 20975 VALLEY GREEN DR CUPERTINO, CA 95014 (E) FOUNDATION TO BE REPLACED (N) FOUNDATION p EXISTING & PROPOSED ELEVATIONS A-3 EXISTING SURFACE 0'-0" AGL EXISTING SURFACE 0'-0" AGL EXISTING ELEVATION SCALE 2 PROPOSED ELEVATION SCALE 1 1/2 1/2 U Y 0 U O OW z U � Z 0 Z � d' a W 0 to 2 Of =�W 0'_ Z 0 = O � Q ~ U U wa'Z Z0 O U OLLI Z Z OW`1OZ LLI �OZ 0 ¢ w ULLI MLLI 0 Z Q 0" Z' 0 � w J W W Z of O Z Om w 0 F— Z Z Q H O O J J LUaO a� (nJZZ OLI O Q O w�zw 0?Qm w F-: M w 0'R 0 �UWW m J(U)Z OQ�a W Q = w z a ZZU) O W OwwF U � LU w 8 Z F < or w N Q Z 0=<— u)~W` Lua�a =O� � ~ W J H m U)0=o w a 0 � =oZ� H Z ¢ Z =Q�CL U Lu w af 0 w c� IL c_) 0 Q ,zl, 0 oCL wCL roCf) r LJ = ZQ Z OUCnUJO LEGEND � ELECTRICAL SERVICE CABINET O# EXISTING LUMINAIRE UNDERGROUND ELECTRICAL SERVICE POINT �# LUMINA[RE W/ CELLULAR EQUIPMENT POLE MOUNTED ELECTRICAL SERVICE POINT MASTER PEU (MOUNTED TO POLE) OR OP STREETLIGHT COMMUNICATION EQUIPMENT CITY SERVICE BOX - GATEWAY (MOUNTED TO POLE) # CIRCUIT NUMBER (HH) HAND -HOLE (NO PULL BOX) • SPLICED CONNECTION F-] PULLBOX (NO SPLICE) ON CD z Lw LUMINAIRES CONTROLLED BY INDIVIDUAL PHOTOCELLS. + DIRECTLY FED FROM POC AND IS NOT FUSED. TYPICAL SERVICE FUSE SIZE OF 30A 40A FUSE CAN BE UTILIZED. @ CONDUCTOR UPSIZING AS INDICATED TO REDUCE VOLTAGE DROP TO <5000% TO BE D( SF CUPERTINO 074 TO PASS VOLTAGE DROP CALCULATIONS. CALCULATIONS FOR CUPI WORK NEEDED FOR CUPERTINO CUPER020. CUPERTINO CUPER020 AS STAND-ALONE SI + WATTAGE FOR PROPOSED CELLULAR EQUIPMENT IS BASED ON UTILIZING ONE RADIO F ONE RADIO RATED AT 68W9 AND TWO RADIOS RATED AT 400W EACH ++ WATTAGE FOR PROPOSED CELLULAR EQUIPMENT IS BASED ON UTILIZING TWO RADIO` SERVICE POINT LOCATION CIRCUIT # BREAKER (FUSE) SIZE POLE ID CELLULAR EQUIPMENT WATTAGE EXISTING LUMINAIRE PROPOSED LUMINAIRE AMPERAGE VOLTAGE DROP EXISTING PROPOSED EXISTING PROPOSED VALLEY GREEN DR & N STEELING RD 1 40A+ 5809 - 40VV ID - 208 2207 1 047% � 4, 7 � 5808 - 4OW ID - 5807 - 4 0 W ID - 5806 29437+ 4OW ID 5805 - 40W ID - 5804 - 40W ID - 5803 - 40W ID - 5802 - 4OW I D - 5800 29360++ 50W ID 176_6 24 - 5 0 W I D - CONSULTANT: WMH Corporation 55 S Market St, Suite1200 San Jose, CA 95113 APPLICANT: Modus, Inc. 240 Stockton Street, 3rd Floor San Francisco, CA 94108 Date: DECEMBER 19, 2019 Scale: NO SCALE Designed: P. BATTH Drawn: P. BATTH Checked: S. VOGTMAN Proj. Engr: S.VOGTMAN File: $REQUEST REVISIONS DESIGN DESIGN CITY APPR. BY DATE APPR. DATE CUPERTINO IMPROVEMENT PLANS FOR MODUS OMT POLES POLE 5800 CUPERTINO CUPER020 CALIFORNIA z 0 Q Ld W FOR CITY OF CUPERTINO USE PROJECT # PUBLIC WORKS KEVIN REIDEN INSPECTOR: VOICE MAIL: (408) 777—JI04 PROJECT ENGINEER NAME DATE CITY OF CUPERTINO SHEET A-4 DATE MARCH 2O15 ERICSSON STREETMACRO 6701 WHITE NOTICE BLUE BACKGROUND 1'-0" DIMENSIONS: 21.2" TALL x 8.1" WIDE x 5.1" DEEP 10 WEIGHT: 31.0± LBS WHITE BACKGROUND TWIN DIPLEXER PCS/AWS DETAIL 7 CBC1 923T-431 0 / El F13P06 rizonve BLACK SYMBOL COLOR: GRAY 8.34" Transmitting Antenna(s) DIMENSIONS: 8.3" TALL x 4.6" WIDE x 1.8" DEEP TOTAL WEIGHT: 4.4 LBS. Radio frequency fields beyond 5.1" 8.1"1 on this point MAY EXCEED the FCC r- - - � VERIZON WIRELESS General Population exposure o limit. TOP VIEW 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA Obey all posted signs an BLACK LETTERING, TYP site guidelines. Call Verizon at 1-800-264-6620 2.5" 8.34" 94598 PRIOR to working beyond this N N 0 0 o paint. 8.1" CC)o � 00 P1000 UNISTRUT o 0 0 2 LOCATIONSId Site I D/ PSLC. WAY _j L- FRONT VIEW (BACK TOBACKINSTALLATION) SIDE VIEW a ID S NOTES:�'� ® Nk_OpO Im 1. OUTDOOR RATED SELF ADHESIVE VINYL DECAL WITH UV PROTECTION. 2. POST SIGN 3'-0" BELOW PROPOSED ANTENNA. TOP VIEW SIDE VIEW FRONT VIEW 3. CONTRACTOR TO CONFIRM SPECIFIC SIGN REQUIREMENTS WITH VERIZON WIRELESS. MODUS, LLC 4. DECAL SHALL FACE OUT THE STREET AND WHEN FEASIBLE AWAY FROM THE STREET, IF NO BUILDING WINDOW IS PRESENT WITHIN 25 FEET FACING THE EXISTING POLE. 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA NOTICE SIGNAGE SCALE 12 BICYCLE WRONG WAY SIGN SCALE 9 ERICSSON 6701 SCALE 6 TWIN DIPLEXER SCALE 3 94108 NTS NTS NTS NTS EAR-LOKT BUCKLE USE DOUBLE 4YRAPPED� BAND CLAMP AP PLIED W ITH G40269 ERICSSION RRUS-32 REMOTE RADIO UNIT NOTES REFER TO DETAIL 10/D1 DRAWN BY: APE TOOL ROR MAXIMUM S7RENGTH AND HOLDING POWER. COLOR: GRAY FOR SHROUD AND 8/D1 FOR D51089 G517.09, D51389 DIMENSIONS: 27.2" TALL X 12.1" WIDE X 7.0" REINFORCEMENT DIAMOND ENGINEERING CHECKED BY: BPM APPROVED BY: LJB SHUTDOWN PROTOCOL - USE G43099 BAND - USEG43299 BA%D - USE G44099 BUCKLE - USE t t-4299 BUCKLE TOTAL WEIGHT: 60 LBS. POWER CONSUMPTION: 740 W SERVICES Normal Shut -Down Protocols: ROAD SIGN (OR APPROVED EQUAL) 1. Call 800-264-6620 NOC 24HRS prior to schedule a shut -down day and time. 7" PART # 2. Give NOC the Node number VVSP360S-AM-00 REV DATE DESCRIPTION 3. On schedule day of shut -down, Put breaker switches in 0 04/03/20 100% CD "OFF"position. 0 4. Call NOC when work is completed. 1 06/24/20 100% CD REV 1 Emergency Shut -Down Protocols: 1'-3" DIA. 2 10/29/20 100% CD PLAN CHECK 1. Call 800-264-6620 NOC. 2. Give NOC the Node number i 3. Put breaker switches in "OFF" position. 3.000000" 4. Call NOC when work is completed. 1 �8" 04 10.437540" I I NOTES: 8•000000" ° ° hi, o 1. SIGN PROVIDED BY GC MOUNTED TO N OUTSIDE OF DISCONNECT COVER H�W�� I � 2. CONTRACTOR TO NOTE SITE ID/ I I MARKET ID/ SITE NAME / PSLC ID b6b CANISTER ANTENNA, LkJ SEE DETAIL 4/D-1 12.1" ROAD SIGN MOUNTING I I o - TOP VIEW SIDE VIEW BRACKET FRONT VIEW I I TWIN DIPLEXER, SHUT -DOWN SIGN SCALE 1 1 STEEL BAND SCALE 8 RRUS 32 SCALE C� SEE DETAIL 3/D-1 egp�...... : O ,. ,��il�s B ,, f �"•., =�,_ C/,Q NTS NTS NTS `� I �, nL_r�= w rr, VVSSP-360S-M - _ NO. C64533 - ANTENNA COLOR: LIGHT GRAY N =. yj ' ., CIVIL = 10" ROAD SIGN MOUNTED TO SIGN x DIMENSIONS: 24.00" TALL Q12.00" �� F O •• QF SUPPORT BRACKET, HDG #8 X 1" NET WEIGHT: 28.7 LBS CAO ,•' HEX TEK-SCREW, TYP. 5G ANTENNA, ......,, SEE DETAIL 6/D-1 ao 1"TYP. IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT I h PLAN U N o NOTCH AT LIGHT \ c� ARM SHEET METAL SKIRT C U P E RTI N O_C U P E R020 12.00" o (NEAR) 20975 VALLEY LO PAN HEAD TEK-SCREW, TYP. OF 4 RRU PER PLAN I I I I N GREEN DR L -- - LIGHT POLE CUPERTINO, CA 95014 I � (N) 12 GA. STEEL "CABLE L SHROUD" REMOVABLE 12 GA. GALV. SHEET STEEL FRONT PANEL 3 1 /4" STREET SIGN SUPPORT ELEVATION VIEW DETAILS SIGN SUPPORT BRACKET MOUNTED TO BACK OF RRU, UTILIZING RRU MOUNTING SCREW PLAN ELEVATION SIDE ELEVATION D-1 CABLE SHROUD SCALE 10 SIG N SUPPORT BRACKET SCALE 7 ANTENNA SCALE 4 ANTENNA SHROUD & SKIRT SCALE 1 NTS NTS NTS NTS SIDEWALK: SUBGRADE SHALL BE COMPACTED TO AT LEAST 95% RELATIVE COMPACTION. 1) WHERE UNSUITABLE SUBGRADE MATERIAL IS ENCOUNTERED, REMEDIAL WORK SHALL BE DONE UNDER THE DIRECTION OF THE CITY ENGINEER, INCLUDES BUT IS NOT LIMITED TO, REMOVING UNSUITABLE MATERIAL AND PLACING A LAYER OF CLASS II AGGREGATE BASE UNDER THE INSTALLATION. 2) UNDERCUT SUBGRADE FOR GUTTER OR SIDEWALK SHALL BE FILLED WITH APPROVED GRANULAR MATERIAL. 3) EXISTING CONCRETE SHALL BE REMOVED AT EXPANSION OR WEAKENED PLANE JOINTS OR AT SAWCUTS. 4) SAWCUTS MUST BE FULL DEPTH. 5) NO UTILITY BOXES, POLES, POSTS OR ANY OTHER FACILITIES OR DEVICES WILL BE PERMITTED IN THE SIDEWALK AREA WITHOUT THE WRITTEN APPROVAL OF THE CITY ENGINEER. 6) NEW WORK SHALL MATCH EXISTING SCORE AND COLOR. 7) SUBGRADE SHALL BE THOROUGHLY WETTED IMMEDIATELY PRIOR TO PLACING CONCRETE. 8) CONCRETE SHALL BE CLASS B-5 SACK MIX WITH 3/4 INCH MAXIMUM AGGREGATE. 9) CONCRETE SHALL HAVE A SLUMP OF NOT MORE THAN 4 INCHES. 10) NO ADMIXTURES SHALL BE USED WITHOUT THE PERMISSION OF THE CITY ENGINEER. 1 1) 1 /2" THICK EXPANSION JOINTS SHALL BE PLACED ON BOTH SIDES OF DRIVEWAY APPROACHES, CURB, GUTTER, AND SIDEWALK RETURN POINTS AND AT 20' ON CENTER. 12) WEAKENED PLANE JOINTS AT LEAST 1 1 /2" DEEP SHALL BE PLACED AT THE CENTER OF DRIVEWAYS AND 20' ON CENTER. 13) 1 /4' DEEP SCORE MARKS SHALL BE PLACED AS DESCRIBED IN THE STANDARD SPECIFICATIONS OR AS DIRECTED BY CITY ENGINEER. 14) NO CONCRETE SHALL BE PLACED UNTIL THE CITY ENGINEER OR HIS AUTHORIZED REPRESENTATIVE HAS INSPECTED AND APPROVED FORMS OF SUBGRADE. 15) ALL EXPOSED EDGES SHALL BE ROUNDED WITH 1 /2" RADIUS TOOL. 16) ALL SURFACES SHALL BE BROOM FINISHED UNLESS OTHERWISE NOTED. 17) CURBS, SIDEWALKS AND DRIVEWAY APPROACHES SHALL BE BACKFILLED WITHIN 7 DAYS AFTER PLACING CONCRETE. THIS SHALL INCLUDE ANT REQUIRED AC PATCHWORK. 18) FORM FACES SHALL NOT VARY FROM THE DIMENSIONS SHOWN BY MORE THAN .02 FEET. FORMS SHALL MEET GRADE. 19) UNLESS OTHERWISE SPECIFIED ON THE APPROVED PLANS, CONCRETE SHALL BE CURED BY MEANS OF THE IMPERVIOUS MEMBRANE METHOD. 20) ALL SIDEWALK CONSTRUCTION ADJACENT TO CURB SHALL BE POURED MONOLITHIC WITH CURB UNLESS OTHERWISE APPROVED BY ENGINEER. 21) ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY SHALL BE COMPLETED NO LATER THAN 5 DAYS AFTER INSTALLATION OF UTILITY. A MINIMUM OF 6" OF ASPHALT SHALL BE REMOVED ALONG THE GUTTER LIP FOR THE INSTALLATION OF FORMS. FOR CURB AND GUTTER INSTALLATIONS AC SHALL BE BROUGHT TO FINISH GRADE OF FORMS AND TRANSITIONED AS REQUIRED BY THE CITY ENGINEER. 22) ALL FACE ANGLE INSTALLATIONS IN RETURNS SHALL MATCH EXISTING RADIUS OF CURB. 1) ALL CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-14. 2) CONTRACTOR SHALL VERIFY SITE CONDITIONS & ALL DIMENSIONS PRIOR TO STARTING WORK. NOTIFY ENGINEER OF RECORD OF ANY DISCREPANCIES. 3) CEMENT SHALL CONFORM TO ASTM C150, TYPE II. 4) CONCRETE AGGREGATES SHALL CONFORM TO ASTM C33. 5) ALL CONCRETE SHALL BE A 5 SACK MIX WITH A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI AT 28 DAYS. 6) ALL REINFORCING STEEL SHALL BE GRADE 60 AND CONFORM TO ASTM A615 UNLESS OTHERWISE NOTED. SEE PLAN FOR SIZE AND PLACEMENT. 7) MINIMUM LAP SPLICE SHALL BE 40 BAR DIAMETERS UNLESS OTHERWISE NOTED. 8) MINIMUM BEND DIAMETER SHALL BE 6 BAR DIAMETERS UNLESS OTHERWISE NOTED. 9) MINIMUM REINFORCING COVERAGE IS Y UNLESS OTHERWISE NOTED. 10) CONCRETE SHALL BE PLACED AGAINST FIRM UNDISTURBED SOIL AT DEPTH SHOWN. 1 1) BOTTOM OF ALL FOOTING TRENCHES SHALL BE CLEAN AND LEVEL. 12) ALL ANCHOR BOLTS & THREADED ROD SHALL BE ASTM F1554 GRADE 55 MINIMUM, UNLESS OTHERWISE NOTED: NEW: & WITHOUT SIGNIFICANT RUST. TOP 2 FEET & HARDWARE TO BE GALVANIZED PER ASTM A 123. 13) A 1 /2" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE UNLESS OTHERWISE NOTED. 14) REINFORCING, DOWELS, BOLTS, ANCHORS, SLEEVES, ETC TO BE EMBEDDED IN CONCRETE SHALL BE SECURELY POSITIONED BEFORE PLACING CONCRETE. 15) ALL CONCRETE SHALL BE THOROUGHLY CONSOLIDATED BY MOTORIZED VIBRATORY MEANS AND THOROUGHLY WORKED AROUND REINFORCEMENT, EMBEDDED ITEMS AND INTO CORNERS OF FORMS WELDING 1) ALL WELDS SHALL BE SHIELDED METAL ARC TYPE (SMAW), IN ACCORDANCE WITH THE "STANDARD CODE FOR ARC AND GAS WELDING IN BUILDING CONSTRUCTION", AWS D1.1, BY THE AMERICAN WELDING SOCIETY. 2) WELDING ROD SHALL BE E70XX, MINIMUM (70 KSI). 3) PERIODIC INSPECTION IS PERMITTED FOR THE FOLLOWING: - SINGLE PASS FIELD WELDS NOT EXCEEDING 5/16" 4) REMOVE ALL EXISTING CONDUCTORS AND GROUND WIRES FROM POLE PRIOR TO WELDING AND INSTALL NEW AFTER WELDING IS COMPLETE IN ACCORDANCE WITH STANDARD SPECIFICATION 86-2.04 (B) 5) WELDING TO BE PERFORMED BY AN AWS CERTIFIED WELDER FOR THE TYPE OF AND POSITION INDICATED. ALL WORK MUST BE IN CONFORMANCE WITH LATEST EDITION OF AISC & AWS D1.1. 6) GRIND SURFACES TO BE WELDED WITH A SILICON CARBIDE WHEEL PRIOR TO WELDING TO REMOVED ALL GALVANIZING WHICH MAY OTHERWISE BE CONSUMED IN THE WELD METAL. APPLY ANTI -SPATTER COMPOUND AFTER GRINDING. 7) WELDING TECHNIQUE MUST MINIMIZE TEMPERATURE RISE ON THE INSIDE SURFACE OF THE LIGHT POLE AND ALSO VOLATIZE ANY REMAINING ZINC WITHIN THE BASE METAL WITH MINIMUM SPATTER. USE AN E70 (LOW HYDROGEN) ELECTRODE. USE LARGEST DIAMETER ELECTRODE COMPATIBLE WITH WELDING POSITION AND MATERIAL THICKNESS. STRICTLY FOLLOW ALL MANUFACTURER'S INSTRUCTIONS FOR STORAGE AND USE OF ELECTRODES. AVOID REMOVING ELECTRODES FROM MANUFACTURER'S PACKAGING UNTIL READY FOR IMMEDIATE USE. 8) WELDING MAY PRODUCE TOXIC FUMES. REFER TO ANSI STANDARD Z49.1 -SAFETY IN WELDING AND CUTTING" FOR PROPER PRECAUTIONS. 9) UPON COMPLETION OF WELDING, APPLY GALV-A-STICK ZINC COATING TO ALL UNPROTECTED SURFACES. APPLY A SECOND LAYER OF COLD GALVANIZING SPRAY COMPOUND CONTAINING A MINIMUM ZINC CONTENT OF 95%. APPLY A FINAL COAT OF COMPATIBLE PAINT TO MATCH SURROUNDING SURFACES. EXCEPTION - CONTINUOUS SPECIAL INSPECTION IS REQUIRED FOR ALL WELDING (NOT LISTED ABOVE) UNLESS PERFORMED IN AN APPROVED FABRICATOR'S SHOP. STRUCTURAL NOTES 1) FOUNDATION SOIL STRATA IS NATIVE SOIL OR ENGINEERED FILL AS PER THE PROJECT SOILS REPORT WHEN APPLICABLE. IF THERE ARE ANY DISCREPANCIES BETWEEN THE SOILS REPORT & THESE PLANS, THE SOILS REPORT SHALL GOVERN. SOILS REPORT: N/A WHEN NO SOILS REPORT IS AVAILABLE, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT ALL SOIL CONDITIONS ARE APPROPRIATE FOR THE CONSTRUCTION OF THIS PROPOSED PROJECT AS SHOWN WITHIN. SOIL DESIGN IS BASED ON CBC SOIL TYPE 5-CLAY, SANDY CLAY, SILTY CLAY, CLAYEY SILT, SILT, AND SANDY SILT (CL, ML, MH AND CH). IF MATERIALS OTHER THAN THOSE LISTED HEREIN ARE PRESENT, OR IF SOIL ENCOUNTERED IS OTHERWISE UNSUITABLE, A GEOTECHNICAL ENGINEER SHALL BE RETAINED FOR OBSERVATION AND RECOMMENDATIONS BEFORE PROCEEDING WITH CONSTRUCTION. AS A RESULT, INCREASED FOOTING DIAMETER AND/OR DEPTH MAY BE REQUIRED. 2) FOUNDATIONS SHALL BEAR ON FIRM, UNDISTURBED SOIL STRATA, OR ENGINEERED FILL. 3) THE BOTTOM OF ALL FOOTINGS SHALL BE LEVEL. 4) CENTER FOOTINGS UNDER COLUMNS UNLESS OTHERWISE INDICATED. 5) OWNER/DEVELOPER AND APPROPRIATE SUBCONTRACTOR(S) ARE RESPONSIBLE FOR REVIEWING THE SOILS REPORT (IF APPLICABLE) PRIOR TO COMMENCING CONSTRUCTION. 6) THE CONTRACTOR AND/OR OWNER SHALL BE RESPONSIBLE FOR ESTABLISHING AND MAINTAINING ALL PROPERTY LINES AND CORNERS AND SHALL ENSURE THAT CONSTRUCTION IS WITHIN ALL APPLICABLE SETBACKS AND EASEMENTS. 7) THE ENTIRE AREA TO BE COVERED BY STRUCTURES SHALL BE CLEARED AND GRUBBED TO REMOVE SURFACE VEGETATION AS REQUIRED. 8) STOP FOUNDATION POUR 3 1/2" BELOW GRADE. PLACE FINISH CAP AFTER STANDARD IS SET AND PLUMBED. BUILD UP GROUT UNDER STANDARD BASE ON LOW SIDE (TYP.). 9) SURFACE OF FINISH CAP TO BE AT GRADE AND SLOPED TO MATCH EXISTING OR FUTURE SIDEWALK (TYP.). 10) ANCHOR BOLT SIZE AND LENGTH AS INDICATED (TYP.). 1 1) 4' SECTION OF ANCHOR BOLT BENT AT 90° RIGHT ANGLE (TYP.). 12) STANDARDS TO BESET AT 1'-9" TO CENTER FROM BACK OF CURB UNLESS SHOWN OTHERWISE. DESIGN CRITERIA • DESIGN STANDARD: 2013 AASHTO-LTS6 • WIND SPEED: 85 MPH • WIND EXPOSURE: C • SOIL LATERAL BEARING VALUE: 1500 PSF SPECIAL INSPECTION • FIELD WELDING • CONCRETE PIER COMPRESSION TESTS • REINFORCING PLACEMENT GROUT: 1) HIGH -STRENGTH NON -SHRINK GROUT SHALL BE PROVIDED BY SAKRETE. 2) GROUT SHALL MEET OR EXCEED ASTM C1 107 SPECIFICATIONS. 3) GROUT SHALL MEET THE PREPARATION/APPLICATION STANDARDS AS LISTED IN ACI 302.1 AND ACI 304.1 4) USE ONLY WHEN THE PRODUCT, AIR, AND SURFACE TEMPERATURE ARE ABOVE 40°F (4°C) FOR A MINIMUM OF 24 HOURS. 5) CLEAN AREA AND REMOVE ALL UNSOUND CONCRETE, GREASE, OIL, PAINT, AND ANY OTHER FOREIGN MATERIAL THAT WILL INHIBIT PERFORMANCE. 6) PRIOR TO GROUT PLACEMENT, ALL SURFACES MUST BE CLEAN AND SATURATED WITH WATER FOR 24 HOURS. REMOVE EXCESS WATER BRINGING IT TO A SURFACE SATURATED FRY CONDITION (SSD). 7) PROVIDE AIR RELIEF HOLES WHERE NECESSARY IF GROUTING IS BENEATH LARGE PLATES. 8) WOOD FORM WORK OR OTHER ABSORBENT FORMS SHOULD BE COATED WITH A FORM RELEASE OIL TO PREVENT GROUT ADHERENCE AND WATER ABSORPTION. 9) DESIGN FORM WORK TO FACILITATE RAPID, CONTINUOUS AND COMPLETE FILLING OF THE SPACE TO BE GROUTED. RODDING THE GROUT LIGHTLY WILL HELP MOVE MATERIAL. 10) USE METHODS THAT WILL ENABLE THE GROUT TO FLOW BY GRAVITY BETWEEN THE SURFACES AND KEEP THE GROUT IN FULL CONTACT WITH THESE SURFACES UNTIL IT HAS HARDENED. 1 1) AVOID VIBRATION WHICH CAN CAUSE BLEEDING AND SEGREGATION. SHUT DOWN NEARBY MACHINES FOR A MINIMUM OF 24 HOURS. 12) MINIMUM APPLICATION THICKNESS IS 1" (25mm) AND A MAXIMUM THICKNESS OF 4" (100mm). 13) FOR INSTALLATION WHERE ACIDS AND SULFATES ARE PRESENT, A PROTECTIVE COATING IS REQUIRED. PROTECT UNCOATED ALUMINUM FROM DIRECT CONTACT WITH PORTLAND CEMENT -BASED MATERIALS. 14) REFER TO: - ACI 351.1 R-99 REPORT ON GROUTING BETWEEN FOUNDATIONS AND BASES FOR SUPPORT EQUIPMENT AND MACHINERY - ACI 351.2R FOUNDATIONS FOR STATIC EQUIPMENT - ACI 306R COLD WEATHER CONCRETING - ACI 305R HOT WEATHER CONCRETING 15) ONLY MIX WITH CLEAN POTABLE WATER. THE WATER QUANTITIES SHOWN ARE APPROXIMATE AND MAY VARY SLIGHTLY WITH THE TYPE OF EQUIPMENT AND APPLICATION CONDITIONS. 16) WATER DEMAND AND MIX TEMPERATURE MUST BE DETERMINED USING STANDARD TEST METHODS FOR CONSISTENCY AND TEMPERATURE MEASUREMENT AT THE TIME OF APPLICATION. 17) PLACE 3/4 OF DESIRED MIXING WATER, START MIXER THEN SLOWLY ADD THE DRY MATERIAL. AFTER ALL OF THE POWDER HAS BEEN ADDED, SLOWLY ADD THE REMAINING 1 /4 WATER UNTIL THE DESIRED CONSISTENCY IS ACHIEVED. 18) AVOID ADDING EXCESSIVE AMOUNTS OF WATER THAT PROMOTES SEGREGATION OR BLEEDING OF THE GROUT. 19) MIX FOR 3-5 MINUTES TO ENSURE A UNIFORM LUMP FREE CONSISTENCY AND PLACE IMMEDIATELY. 20) SAKRETE NON -SHRINK CONSTRUCTION GROUT CAN BE EXPOSED UNDER NORMAL WEATHERING CONDITIONS. 21) FORMS MAY BE REMOVED AS SOON AS THE GROUT REACHES ITS FINAL SET. 22) PREVENT RAPID WATER LOSS BY COVERING THE EXPOSED GROUT SURFACES WITH WET BURLAP DURING THE FIRST 48 HOURS OR APPLY AN ACCEPTABLE WATER BASED CURE AND SEAL AGENT. 23) PROTECT FROM FREEZING FOR A MINIMUM OF 48 HOURS AFTER PLACEMENT. ACI 308 STANDARD PRACTICE FOR CURING CONCRETE. 24) AIR, MIX AND SUBSTRATE TEMPERATURES SHOULD BE BETWEEN 40OF (4°C) AND 90°F (320C). - COLDER TEMPERATURES OR HIGHER HUMIDITY CONDITIONS WILL RETARD SET TIMES. - DO NOT USE IN APPLICATIONS OF HIGH DYNAMIC LOADING. - DO NOT RETEMPER GROUT BY ADDING WATER. - DO NOT USE A FLOOR TOPPING OR IN LARGE AREAS WITH AN EXPOSED SHOULDER AROUND BASE PLATES. 25) READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) BEFORE USING THIS PRODUCT. WARNING: WEAR PROTECTIVE CLOTHING AND EQUIPMENT. FOR EMERGENCY INFORMATION, CALL CHEMTREC AT 800-424-9300 OR 703-527-3887 (OUTSIDE USA). 7 POLE PER PLAN B LL O z N LL NOTE: TOTAL ANCHOR PROJECTION IS 2 5/8" PLUS THE GROUT PAD THICKNESS (2) GALV HEX NUTS & (2) GALV FLAT WASHERS PER BOLT 1" MAX. HIGH STRENGTH NON SHRINK GROUT RACO 1/2"-l"BRONZE GROUND CLAMP OR EQUIVALENT, (4) TOTAL II =o U Q 3" MIN. U CLR. TYP — Lo III III II J 3 Lu w u = OJ-- #=4' m I— II II II II I— —I 91 I—° II 11 _°°all Ip 7 r 7. 1= i— 0 Lu III II °II ` dll IL II II II II II II II` II z M0 �L—_4 3" MIN. CLR.TYP 2'-6" DIA. A. NEW DRILLED PIER SECTION PIER BASE PLATE PER POLE MFG. BOLT CIRCLE PER POLE MFG. GROUNDING PROVISION NUT RETAINER WELDED OPPOSITE HANDHOLE ON POLE WALL W/ 1 /2" - 13NC SS SQ NUT & 3/4" LG SS HEX BOLT PIER 900 1 N 3" MIN. CLR.TYF B. PLAN VIEW BASE PLATE C. PLAN VIEW PIER 450 D D D. HOOK AND BENDS 90° 135° D D bd t� E. STIRRUP & TIES PIER FOUNDATION (2) 1 1/2" DIA. CONDUIT ANCHOR BOLTS PER POLE SPEC, (4) TOTAL, SEE SHEET D-3 ANCHOR PLATE PER POLE SPEC, SEE SHEET D-3 #4 TIES @ 12" O.C. (3) WITHIN TOP 5" #6 REBAR VERT, (6) TOTAL NOTES: LID 1. POLYMER CONCRETE CONSTRUCTION 2. STANDARD LOAD RATING 20,800 LBS 3. TWO (2) BOLT DOWN LOCATIONS 4. NON SKID SURFACE STANDARD 5. APPROXIMATE WEIGHT 104 LBS BOX 1. POLYMER CONCRETE CONSTRUCTION 2. STACKABLE FOOT 3. APPROXIMATE WEIGHT 150LBS BOLT DOWN TYP. OF (2) NON SKID SURFACE (STANDARD) 3/8" X 3" HEX BOLT (2 EACH END) FIBER PULLBOX ellill ME' IN 3" LIFT PIN TYP. OF (2) 2"X8" NAMEPLATE RECESS 3 verizon)/ VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 DRAWN BY: APE CHECKED BY: BPM APPROVED BY: LJB POLE PER PLAN REV DATE DESCRIPTION 0 04/03/20 100% CD 1 06/24/20 100% CD REV 1 HAND HOLE COVER 2 10/29/20 100% CD PLAN CHECK VANDAL RESISTANT SCREW SAW CUT (E) SIDEWALK TO FLAG LINES ANCHOR BOLTS PER POLE SPEC, (4) TOTAL, SEE SHEET D-3 #4 TIES @ 12" O.C. (3) WITHIN TOP 5" #6 REBAR VERT, (6) TOTAL 2 1 /2" MIN. 4d n 1800 D=6d FOR #3 THRU #8 INSIDE BEND DIAMETER BAR SIZE D #3 1 1 /2" #4 2" #5 2 1 /2" D= 1 /2" FOR #4 BARS D= 3/4" FOR #6 BARS NOT USED PORT TYPE A (PIPE) C D DISCONNECT 2"± 1-1 /2" 1 1 /2" 3/4" RRU 2"± 1-1/2" 1 1/2" 3/4" SCHED. 40 STD PIPE TAPERED STEEL LIGHT POLE 1 /16" CHAMFER MIN I.S. & O.S. TYP U o WA 3/16 SCHED. 40 STD PIPE SECTION A -A TAPERED STEEL LIGHT POLE 1 /16" CHAMFER MIN I.S. & O.S. TYP U o A 3/16 SCHED. 40 STD PIPE NOTE: COLD SPRAY GALVANIZE AFTER WELDING 4 CABLE ACCESS AT POLE ELEVATION 2 TAPERED STEEL LIGHT POLE AT RRU: 1-1/2" SCHEDULE 40 STEEL PIPE CUT HOLE TO 1/16" LARGER THAN NOMINAL PIPE DIA., TYP. 'QRflF ESS NOES B' F Op 2 _ Ln NO. C64533 _CIVIL���__ OF C �L1F0 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT CUPERTINO_CUPER020 (NEAR) 20975 VALLEY GREEN DR CUPERTINO, CA 95014 AT LOAD CENTER: DETAILS 1-1 /2" SCHEDULE 40 STEEL PIPE D-2 SCALE NTS 11Lk' DETAIL 2 DETAIL 1 "R" 34' -3" NOMINAL 6.25" LUMINAIRE VSEE MOUNTING DETAIL 4 LUMINAIRE HEIGHT DETAIL 3 ARM DATA SEE POLE DATA DESIGN CRITERIA: AASHTO 2013 DETAIL 5 WIND VELOCITY: DETAIL 6 100 MPH ❑ETAIL 7 DETAIL 8 8 MATERIAL DATA FINISH DATA MIN. COMPONENT ASTM YIELD DESIGNATION (KSI) SYSTEM: GALVANIZED - NO AEROSOL REPAIR BASE COAT: HOT -DIP GALVANIZED TO ASTM A123 PRIME COAT: NONE FINISH COAT: NONE COLOR: NONE TAPERED TUBES A595 GR. A 55 BASE PLATE A572 GR.50 50 SIMPLEX PLATES A572 GR.50 50 GUSSETS A572 GR.50 50 LUM. CONN.BOLTS A325 -- A501,A513,A618 PIPE / TUBING A500 GR. B OR C 36 SPEC: F-544 ANCHOR BOLTS F1554 GR.55 55 HARDWARE COATING HOT DIP ZINC -- REMOVABLE POLE CAP L I DETAIL I POLE CAP 8.00" NOMINAL STRAIGHT SECTION REFORMED TO 2.38" O.D. 20 8.00„ RISE DETAIL 2 1 LUMINAIRE ARM END 2.50" DIA. ACCES5 HOLE 0 31" 6.63" 4.63 25 25 0.94" 1.50" 5.75" i I F_ 5.aa" 2.50" !I 7.63" 0.250" (3) -0 .63" X THICK 1.75" HEX GALVANIZING 25 GUSSETS CAP SCREWS DRAIN HOLE 00.38" 0.750" 1.000" DETAIL 3 LUMINAIRE ARM ATTACHMENT POLE DATA POLE TUBE POLE BASE ANCHOR BOLT ANCHOR PLATE LUMINAIRE ARM TUBE G}TY. BASE TOP GAUGE SQUARE BOLT THK. SLOT THREAD ARM GAUGE ARM RISE OIA. DIA LENGTH OR „ „S CIRCLE „M „Z DIA. LENGTH LENGTH W1 W2 W3 W4 BASE OR SPAN HEIGHT (IN) . (IN) (FT) THK . (IN) ,� �� Y (IN) (IN) (IN) (IN} (IN) (IN) (IN) (IN) (IN) DIA . THK . L R „ (IN) (IN) (IN) (IN) (FT) (FT) 7 8.00 3.80 30.00 7 11.50 11.00 1.00 1.38 X 1.94 1.25 42.00 10.00 7.78 6.75 1.88 10.50 4.68 11 15.33 4.75 C AT7 04/19/18 B ❑J7 03/07/18 A DJ7 03/06/18 DJ7 03/01/18 REV DRAWN BY -DATE FOUNDATION DJ7 04/19/18 RMVD POLE TOP CONN.SMASTIUPD FOR RECORD SOLD TO: VERIZON WIRELESS DJ7 03/07/18 UPD RADOME HEIGHT TO 5'-5"/AD❑ED RA❑OME CAP SHIP TO: SF CUPERTINO CUPER001 DJ7 03/06/18 ADDED POLE AND POLE TOP ASSEMBLY P.D. #: NNCA323040 DJ7 03/01/18 - - - - - - - - - - - - - - - AGENT: EPIC MARKETING CO, INC. CHECK BY -DATE DESCRIPTION PULE TUBE WALL COVER ATTACHMENT LUG - 7 GA. X 1" H.R.M.S. BAR 7 GA. RIM. ""NDHULE COVER GA, H,R.M.S. 0.25"X3" PAN HEAD MACHINE SCREW 0.50" MIN. 1.50" DETAIL 4 1 311x5" HANDHOLE ` 7. 0.50" NUT HOLDER FOR GROUNDING MELDED TO INTERIOR OF POLE SHAFT AT 1800 FROM HANDHOLE RIM. FASTENERS PROVIDED. 0.250" THICK H.R.M.S. HANDHOLE MOUNTING BAR 0.31"-18UNC X 2.00" HEX SOCKET FLAT HEAD SCREW - STAINLESS STEEL HANDHOLE COVER- 11 GA. H.R.M.S, W/COUNTERSUNK 2.25"0 HOLE i- 0. 280 T L POLE SHAFT WALL HANDHOLE RIM FORMED FROM PIPE SIZE TUBING. DETAIL 5 HANDHOLE ALL ANGLES MEASURED CLOCKWISE FROM HAND HOLE AS VIEWED FROM SMALL END OF POLE e3X5 HANDHOLE `�OB ODAS STREET LIGHT PROJECT CUPERTINO, CALIFORNIA TITLE SMALL CELL STRUCTURES gLUMINAIRE ARM ANCHOR BOLT HOLE SLOWER HANDHOLE RADIAL INDEX VALMONT INDUSTRIES, INC. RESERVES THE RIGHT TO INSTALL VARIOUS, ENGINEER APPROVED, MATERIAL HANGING ACCOMMODATIONS TO FACILITATE THE MANUFACTURING PROCESS. n MI, Y I S il POLE BASE / ❑IA. +0.06" 1.50" RADIUS Z DETAIL 67 POLE BASE DI A. (4) -ANCHOR BOLTS WITH (4) HEX NUTS AND (4) WASHERS THREAD PER BOLT WITH THREADED END LENGTH LENGTH GALVANIZED AT LEAST 12.00" ANCHOR PLATE DETAIL 7 ANCHOR BOLT W3 W1 �0.500" W2 „Y„ 1 w4 W1 W2 I I 1 ANCHOR BOLT w3 DIAMETER + 0.06" DETAIL 8 ANCHOR PLATE ALTHOUGH RARE, VIBRATIONS SEVERE ENOUGH TO CAUSE DAMAGE CAN OCCASIONALLY OCCUR IN STRUCTURES OF ALL TYPES. BECAUSE THEY ARE INFLUENCED BY MANY INTERACTING VARIABLES, VIBRATIONS ARE GENERALLY UNPREDICTABLE. THE USER'S MAINTENANCE PROGRAM SHOULD INCLUDE OBSERVATION FOR EXCESSIVE VIBRATION AND EXAMINATION FOR ANY STRUCTURAL DAMAGE OR BOLT LOOSENING. THE VALMONT WARRANTY SPECIFICALLY EXCLUDES FATIGUE FAILURE OR SIMILAR PHENOMENA RESULTING FROM INDUCED VIBRATION, HARMONIC OSCILLATION DR RESONANCE ASSOCIATE❑ WITH MOVEMENT OF AIR CURRENTS AROUND THE PRODUCT. VIBRATION DISCLAIMER Valley,NE 68064 i402) 359-2201 ORDER NUMBER: 377953-P1 PAGE NUMBER: 1 OF 2 DRAWING NUMBER TEV CA377953P verizon, VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 DRAWN BY: APE CHECKED BY: BPM APPROVED BY: LJB REV DATE DESCRIPTION 0 04/03/20 100% CID 1 06/24/20 100% CD REV 1 2 10/29/20 1000 CD PLAN CHECK IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT CUPERTINO_CUPER020 (NEAR) 20975 VALLEY GREEN DR CUPERTINO, CA 95014 POLE SPECS D-3 - - - _�; J L �L— u J — — — _ Lu _ -- - - -_ - - L7- '-,J -u + _ i.kES' BY SPRAY APPLICATION- _ 7 ;-� _ _ ROLLING: — - F>' �':! — — - -- _ _-_�_ Y SANb dA 1 10 -1„4 .�0; PLAGE:tiwfi - r ---- - - _ lyn lum -CLA c -lot I S-TING TFIIryl�ih2) BASS? TlfJd A 6 MIN;7YP �° CUT `- TH C 0 `13F�� _ FILL DEPTH AC Rf:MOVAL ` ` A.C. ; v w—r� TO 9y74r- SEENOt '1:=-- - - ' •AN /, SI V TI - r GLE c T CK DES OF -XCA A ON - - -- - ANU BETKEN COURSES -- CLASS,' I, TYPE- t i r -- , ^ ' SPRAY AN APPLICATION OF -SS -I l - OR ,I1IJii AS-APPROVVM I Y'"i_ClaUI, QN I3EFOkE PLACING A..0 - - THL. CI1 Y LNGINLLN _ t . _ . _ — L1MiIT�_OF X -- t'OD CLASS II OR "CLASS III AGGREGATE BASE AT - - - - - - - COMPAt •f10N, a y BACKIILL- SHAi.L BE B�;Kk'ILI, � u;• I NATIVE MATf;RIALS MAY ONLY WiTPI WRf I`T l CONSF'NT-- t: ENGINEER. NATI\i( 4CKFILI Ct7tv1�1sf`fit t BF_ %, IINLF-SS OTI-iE;RWISE "P-RMI'fl-FD IN WRI ZING BY THE CITY ENGINEER. Rr LAIIVE - - CO-0k'TION PER AS I-M 015S7, D2922, D2.21- AND 03017. CONTRACTOR SHALL VLPJFY SUIT .ABILITY OF NATIVE BACKFILL PRIOR fFO- BE: INNING CON aTRUCTIUN: - - 2) IF f-D04- OF TRENCH IS 3' Of LESS f` cim , -- THE LIP OF GU'ITF.R, TI=iF: COIJTRACTOR SHALL - RLPAVL TO Tl fE _LIP .'Or GOTTCI?.,- _ EXISTING STREET TRENCH RETORATI0 FOR ,ALL-'UBLIC STORM REV 2/ 6/17 CITY OF PEFdT(?40 AF'RROVED 8�'; z�_ DATE;;_ 7-/13/,,' d-24 STAN�AE�b:_f ET,' TLC _.__-- ;CITY ENGINEER-. --------. --..-- — - _ - SpT STATE NOTE: I I c . is Ni °v�b ,uii E��• I � 1 � -, is• � �Gti,�_�5�, �rQ, '•�"� :'�.'. � a'c'�" � � "�".:S�K'If'�= »_ n,. .r.Sl CITY STANDARD DETAILS Awl .i Y• .I r a - I I � ) ; "a i • 51�. .Y .'S4.F'&:' 1 yY 4. � ;. "��wr YS, ,, "op a j{'�r 7» a ` --. '. verizon- VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 m0DUS MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 DRAWN BY: APE CHECKED BY: BPM APPROVED BY: LJB REV DATE DESCRIPTION 0 04/03/20 100% CD 1 06/24/20 100% CD REV 1 2 10/29/20 100% CD PLAN CHECK IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT CUPERTINO_CUPER020 (NEAR) 20975 VALLEY GREEN DR CUPERTINO, CA 95014 CITY STANDARD DETAILS D-4 ELECTRICAL NOTES 1. GENERAL REQUIREMENTS A. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST RULES AND REGULATIONS OF THE NATIONAL ELECTRIC CODE AND ALL STATE AND LOCAL CODES. NOTHING IN THESE PLANS OR SPECIFICATIONS SHALL BE CONSTRUED AS TO PERMIT WORK NOT CONFORMING TO THE MOST STRINGENT OF THESE CODES. SHOULD CHANGES BE NECESSARY IN THE DRAWINGS OR SPECIFICATIONS TO MAKE THE WORK COMPLY WITH THESE REQUIREMENTS, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING AND CEASE WORK ON PARTS OF THE CONTRACT B. THE CONTRACTOR SHALL MAKE A SITE VISIT PRIOR TO BIDDING AND CONSTRUCTION TO VERIFY ALL EXISTING CONDITIONS AND SHALL NOTIFY THE ENGINEER IMMEDIATELY UPON DISCOVERY OF ANY DISCREPANCIES. THE CONTRACTOR ASSUMES ALL LIABILITY FOR FAILURE TO COMPLY WITH THIS PROVISION. C. THE EXTENT OF THE WORK IS INDICATED BY THE DRAWINGS, SCHEDULES, AND SPECIFICATIONS AND IS SUBJECT TO THE TERMS AND CONDITIONS OF THE CONTRACT. THE WORK SHALL CONSIST OF FURNISHING ALL LABOR, EQUIPMENT, MATERIALS AND SUPPLIES NECESSARY FOR A COMPLETE AND OPERATIONAL ELECTRICAL SYSTEM. THE WORK SHALL ALSO INCLUDE THE COMPLETION OF ALL ELECTRICAL WORK NOT MENTIONED OR SHOWN WHICH ARE NECESSARY FOR SUCCESSFUL OPERATION OF ALL SYSTEMS. D. THE CONTRACTOR SHALL PREPARE A BID FOR A COMPLETE AND OPERATIONAL SYSTEM, WHICH INCLUDES THE COST FOR MATERIAL AND LABOR. E. WORKMANSHIP AND NEAT APPEARANCE SHALL BE AS IMPORTANT AS THE OPERATION. DEFECTIVE OR DAMAGED MATERIALS SHALL BE REPLACED OR REPAIRED PRIOR TO FINAL ACCEPTANCE IN A MANNER ACCEPTABLE TO OWNER AND ENGINEER. F. COMPLETE THE ENTIRE INSTALLATION AS SOON AS THE PROGRESS OF THE WORK WILL PERMIT. G. ANY ERROR, OMISSION OR DESIGN DISCREPANCY ON THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION OR CORRECTION BEFORE CONSTRUCTION. H. "PROVIDE" INDICATES THAT ALL ITEMS ARE TO BE FURNISHED, INSTALLED AND CONNECTED IN PLACE. I. CONTRACTOR SHALL SECURE ALL NECESSARY BUILDING PERMITS AND PAY ALL REQUIRED FEES. 2. EQUIPMENT LOCATION A. ALL DRAWINGS INDICATE DIAGRAMMATICALLY THE DESIRED LOCATIONS OR ARRANGEMENTS OF CONDUIT RUNS, OUTLETS, EQUIPMENT, ETC., AND ARE TO BE FOLLOWED AS CLOSELY AS POSSIBLE. PROPER JUDGEMENT MUST BE EXERCISED IN EXECUTING THE WORK SO AS TO SECURE THE BEST POSSIBLE INSTALLATION IN THE AVAILABLE SPACE AND TO OVERCOME LOCAL DIFFICULTIES DUE TO SPACE LIMITATIONS OR INTERFERENCE OF STRUCTURE CONDITIONS ENCOUNTERED. B. IN THE EVENT CHANGES IN THE INDICATED LOCATIONS OR ARRANGEMENTS ARE NECESSARY, DUE TO FIELD CONDITIONS IN THE BUILDING CONSTRUCTION OR REARRANGEMENT OF EQUIPMENT, SUCH CHANGES SHALL BE MADE WITHOUT COST, PROVIDING THE CHANGE IS ORDERED BEFORE THE CONDUIT RUNS, ETC., AND WORK DIRECTLY CONNECTED TO THE SAME IS INSTALLED AND NO EXTRA MATERIALS ARE REQUIRED. C. COORDINATE THE WORK OF THE SECTION WITH THAT OF ALL OTHER TRADES. WHERE CONFLICTS OCCUR, CONSULT WITH THE PERSPECTIVE CONTRACTOR AND COME TO AGREEMENT AS TO CHANGES NECESSARY. OBTAIN WRITTEN ACCEPTANCE FROM ENGINEER FOR THE PROPOSED CHANGES BEFORE PROCEEDING. 3. TESTS A. BEFORE FINAL ACCEPTANCE OF WORK, THE CONTRACTOR SHALL INSURE THAT ALL EQUIPMENT, SYSTEMS, FIXTURES, ETC., ARE WORKING SATISFACTORILY AND TO THE INTENT OF THE DRAWINGS. 4. PERMITS A. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING OUT AND PAYING FOR ALL THE REQUIRED PERMITS, INSPECTION AND EXAMINATION WITHOUT ADDITIONAL EXPENSE TO THE OWNER. 5. GROUNDING A. THE CONTRACTOR SHALL PROVIDE A COMPLETE, AND APPROVED GROUNDING SYSTEM INCLUDING ELECTRODES. ELECTRODE CONDUCTOR, BONDING CONDUCTORS, AND EQUIPMENT CONDUCTORS AS REQUIRED BY ARTICLE 250 OF NATIONAL ELECTRICAL CODE. B. CONDUITS CONNECTED TO EQUIPMENT AND DEVICES SHALL BE METALLICALLY JOINED TOGETHER TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY. C. FEEDERS AND BRANCH CIRCUIT WIRING INSTALLED IN A NONMETALLIC CONDUIT SHALL INCLUDE A CODE SIZED GROUNDING CONDUCTOR HAVING GREEN INSULATION. THE GROUND CONDUCTOR SHALL BE PROPERLY CONNECTED AT BOTH ENDS TO MAINTAIN ELECTRICAL CONTINUITY. D. REFER TO GROUND BUS DETAILS. PROVIDE NEW GROUND SYSTEM COMPLETE WITH CONDUCTORS, GROUND ROD AND DESCRIBED TERMINATIONS. E. ALL GROUNDING CONDUCTORS SHALL BE SOLID TINNED COPPER AND ANNEALED #2 UNLESS NOTED OTHERWISE. F. ALL NON -DIRECT BURIED TELEPHONE EQUIPMENT GROUND CONDUCTORS SHALL BE #2 STRANDED, THHN (GREEN) INSULATION. G. ALL GROUND CONNECTIONS SHALL BE MADE WITH "HYGROUND" COMPRESSION SYSTEM BURNDY CONNECTORS EXCEPT WHERE NOTED OTHERWISE. H. PAINT AT ALL GROUND CONNECTIONS SHALL BE REMOVED. I. GROUNDING SYSTEM RESISTANCE SHALL NOT EXCEED 5 OHMS. IF THE RESISTANCE VALUE IS EXCEEDED, NOTIFY THE OWNER FOR FUTURE INSTRUCTION ON METHODS FOR REDUCING THE RESISTANCE VALUE. SUBMIT TEST REPORTS AND FURNISH TO VERIZON ONE COMPLETE SET OF PRINTS SHOWING "INSTALLED WORK". 6. UTILITY SERVICE A. TELEPHONE AND ELECTRICAL METERING FACILITIES SHALL CONFORM TO THE REQUIREMENTS OF THE SERVING UTILITY COMPANIES. CONTRACTOR SHALL VERIFY SERVICE LOCATIONS AND REQUIREMENTS. SERVICE INFORMATION WILL BE FURNISHED BY THE SERVING UTILITIES. B. CONFORM TO ALL REQUIREMENTS OF THE SERVING UTILITY COMPANIES. 7. PRODUCTS A. ALL MATERIALS SHALL BE NEW, CONFORMING WITH THE NEC, ANSI, NEMA, AND THEY SHALL BE U.L. LISTED AND LABELED. B. CONDUIT: B. 1. RIGID CONDUIT SHALL BE U.L. LABEL GALVANIZED ZINC COATED WITH ZINC INTERIOR AND SHALL BE USED WHEN INSTALLED IN OR UNDER CONCRETE SLABS, IN CONTACT WITH THE EARTH, UNDER PUBLIC ROADWAYS, IN MASONRY WALLS OR EXPOSED ON BUILDING EXTERIOR, RIGID CONDUIT IN CONTACT WITH EARTH SHALL BE 1 /2 LAPPED WRAPPED WITH HUNTS WRAP PROCESS NO. 3. B.2. ELECTRICAL METALLIC TUBING SHALL HAVE U.L. LABEL, FITTINGS SHALL BE COMPRESSION TYPE. EMT SHALL BE USED ONLY FOR INTERIOR RUNS. B.3. FLEXIBLE METALLIC CONDUIT SHALL HAVE U.L. LISTED LABEL AND MAY BE USED WHERE PERMITTED BY CODE. FITTINGS SHALL BE "JAKE" OR "SQUEEZE" TYPE. SEAL TIGHT FLEXIBLE CONDUIT. ALL CONDUIT IN EXCESS OF SIX FEET IN LENGTH SHALL HAVE FULL SIZE GROUND WIRE. B.4. ALL UNDERGROUND CONDUITS SHALL BE PVC SCHEDULE 40 (UNLESS NOTED OTHERWISE) AT A MINIMUM DEPTH OF 24" BELOW GRADE. B.5. ALL CONDUIT ONLY (C.O.) SHALL HAVE PULL ROPE. C. ALL WIRE AND CABLE SHALL BE COPPER, 600 VOLT, #12 AWG MINIMUM UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. CONDUCTORS # 10 AWG AND SMALLER SHALL BE SOLID. CONDUCTORS #8 AWG AND LARGER SHALL BE STRANDED. TYPE THHN INSULATION USED UNLESS CONDUCTORS INSTALLED IN CONDUIT EXPOSED TO WEATHER, IN WHICH CASE TYPE THWN INSULATION SHALL BE USED. D. PROVIDE GALVANIZED COATED STEEL BOXES AND ACCESSORIES SIZED PER CODE TO ACCOMMODATE ALL DEVICES AND WIRING. E. TOGGLE SWITCHES SHALL BE 20 AMP, 120 VOLT AC, SPECIFICATION GRADE WHITE (UNLESS NOTED OTHERWISE) FINISH. MOUNT SWITCHES AT +48" ABOVE FINISHED FLOOR. F. PANELBOARD SHALL BE DEAD FRONT SAFETY TYPE WITH ANTI -BURN SOLDERLESS COMPRESSION APPROVED FOR COPPER CONDUCTORS, COPPER BUS BARS, FULL SIZED NEUTRAL BUS, GROUND BUS AND EQUIPPED WITH QUICK -MAKE QUICK -BREAK BOLT -IN TYPE THERMAL MAGNETIC CIRCUIT BREAKERS. MOUNT TOP OF THE PANELBOARD AT 6'-3" ABOVE FINISHED FLOOR. PROVIDE TYPEWRITTEN CIRCUIT DIRECTORY. G. ALL CIRCUIT BREAKERS, MAGNETIC STARTERS AND OTHER ELECTRICAL EQUIPMENT SHALL HAVE AN INTERRUPTING RATING NOT LESS THAN MAXIMUM SHORT CIRCUIT CURRENT TO WHICH THEY MAY BE SUBJECTED. H. GROUND RODS SHALL BE COPPER CLAD STEEL, 5/8" ROUND AND 10' LONG. COPPERWELD OR APPROVED EQUAL. I. CONDUIT REQUIREMENTS (TYP., U.N.O.): UNDERGROUND: PVC (SCHED 40 OR 80), INDOOR: EMT (RGS IN TRAFFIC AREAS, OUTDOOR (ABOVE GRADE): RGS. J. PLACE "TRUE TAPE" AND PULL ROPE IN THE CONDUITS AS REQUIRED. 8. INSTALLATION A. PROVIDE SUPPORTING DEVICES FOR ALL ELECTRICAL EQUIPMENT, FIXTURES, BOXES, PANEL, ETC., EQUIPMENT SHALL BE BRACED TO WITHSTAND HORIZONTAL FORCES IN ACCORDANCE WITH STATE AND LOCAL CODE REQUIREMENTS. PROVIDE PRIOR ALIGNMENT AND LEVELING OF ALL DEVICES AND FIXTURES. 9. PROJECT CLOSEOUT A. UPON COMPLETION OF WORK, CONDUCT CONTINUITY, SHORT CIRCUIT, AND FALL POTENTIAL GROUNDING TESTS FOR APPROVAL. SUBMIT TEST REPORTS TO PROJECT MANAGER. CLEAN PREMISES OF ALL DEBRIS RESULTING FROM WORK AND LEAVE WORK IN A COMPLETE AND UNDAMAGED CONDITION. B. PROVIDE PROJECT MANAGER WITH ONE SET OF COMPLETE "AS INSTALLED" DRAWINGS AT THE COMPLETION OF THE JOB, SHOWING ACTUAL DIMENSIONS, ROUTINGS AND CIRCUITS. GENERAL ABBREVIATIONS A AMPERE MFR MANUFACTURER ACCA ANTENNA CABLE COVER MIN MINIMUM ASSEMBLY MLO MAIN LUGS ONLY AIC AMPERE INTERRUPTING MTD MOUNTED CAPACITY MTG MOUNTING APPROX APPROXIMATELY MTS MANUAL TRANSFER SWITCH AT AMPERE TRIP N NEUTRAL AWG AMERICAN WIRE GAGE (N) NEW BATT BATTERY NEMA NATIONAL ELECTRICAL BD BOARD MANUFACTURERS ASSOC. BR BRANCH OH OVERHEAD BRKR BREAKER P POLE BTCW BARE TINNED COPPER WIRE PCs PERSONAL BTS BASE TRANSMISSION SYSTEM COMMUNICATION SYSTEM C CONDUIT PH PHASE CAB CABINET PNLBD PANELBOARD CB CIRCUIT BREAKER PPC POWER PROTECTION CABINET CKT CIRCUIT PRC PRIMARY RADIO CABINET CONT CONTINUOUS PRI PRIMARY DEM DEMAND PWR POWER (E) EXISTING RCPT RECEPTACLE EGR EMERGENCY GEN. RECEPTACLE RGS RIGID GALVANIZED STEEL ELEC ELECTRICAL SAF SAFETY EMT ELECTRICAL METALLIC TUBING SDBC SOFT DRAWN BARE COPPER ENCL ENCLOSURE SEC SECONDARY EXIST EXISTING S.N. SOLID NEUTRAL FAC FACTOR SURF SURFACE F/A FIRE ALARM SW SWITCH FLUOR FLUORESCENT TEL TELEPHONE FT FOOT/FEET TYP TYPICAL FU FUSE U/G UNDERGROUND G GROUND U.L. UNDERWRITER'S LABORATORY GEN GENERATOR INC. GFCI GROUND FAULT CIRCUIT U.N.O. UNLESS NOTED OTHERWISE INTERRUPTER V VOLT GND GROUNDING VAC VOLT ALTERNATING CURRENT GPS GLOBAL POSITIONING SYSTEM W WATT OR WIRE GR GROWTH W/ WITH HDBC HARD DRAWN COPPER WIRE W/O WITHOUT HPS HIGH PRESSURE SODIUM XFER TRANSFER LG LENGTH XFMR TRANSFORMER LPS LOW PRESSURE SODIUM XLPE CROSS-LINK POLYETHYLENE MAX MAXIMUM MECH MECHANICAL ELECTRICAL LEGEND OHT/OHP OVERHEAD TELEPHONE/OVERHEAD POWER OHT OVERHEAD TELEPHONE LINE OHP OVERHEAD POWER LINE E POWER RUN T TELCO RUN E/T POWER/TELCO RUN G GROUND LINE —a= FUSE, SIZE AND TYPE AS INDICATED. LIGHTING FIXTURE 5/8" X 10'-0" ,CU. GND ROD 24" MIN. BELOW GRADE. MECHANICAL CONNECTION fL CIRCUIT BREAKER verizonNI VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 r lq MODUS MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 DRAWN BY: APE CHECKED BY: BPM APPROVED BY: LJB REV DATE DESCRIPTION 0 04/03/20 100% CD 1 06/24/20 100% CD REV 1 2 10/29/20 100% CD PLAN CHECK OQgflFESSlo/ ., NO. C64533 _CIVIL���__ OF C �L1F0 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT CUPERTINO_CUPER020 (NEAR) 20975 VALLEY GREEN DR CUPERTINO, CA 95014 ELECTRICAL GENERAL NOTES E-1 NOTES: 1. GROUND ROD: UL LISTED COPPER CLAD STEEL. MINIMUM 5/8" DIAMETER x 10'-0" LONG. ALL GROUND RODS MAY BE INSTALLED WITH INSPECTION SLEEVES. GROUND RODS SHALL BE DRIVEN TO THE DEPTH OF GROUND CONDUCTOR. 2. CELL REFERENCE GROUND BAR: POINT OF GROUND REFERENCE FOR ALL COMMUNICATIONS EQUIPMENT FRAMES. ALL BONDS ARE MADE WITH GREEN INSULATED COPPER CONDUCTORS, SIZED AS SHOWN. BOND TO GROUND ROD AS SHOWN IN THE GROUNDING SCHEMATIC. 3. EXTERIOR UNIT BONDS: METALLIC OBJECTS SHALL BE BONDED TO THE EXTERIOR GROUND ROD. 4. PROVIDE ALL ELECTRICAL WORK & MATERIALS AS SHOWN ON THE DWGS, AS CALLED FOR HEREIN, & AS IS NECESSARY TO FURNISH A COMPLETE INSTALLATION. 5. OUTDOOR EQUIPMENT SHALL BE RATED NEMA 3R AND/OR UL LISTED FOR WET ENVIRONMENT. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING THE GROUNDING SYSTEM AND ENSURING A 5 OHM OR LESS GROUNDING PATH. ADDITIONAL GROUND RODS AND/OR CHEMICAL ROD SYSTEM SHALL BE USED IF THE GIVEN DESIGN CANNOT BE MADE TO ACHIEVE THIS REQUIREMENT. IU UIHLK JIKLLI LIUHIJ ,T�l CITY SERVICE CONDUCTORS w STREET LIGHT PULL BOX o- CITY SERVICE CONDUCTORS TO SERVICE POINT (N) WATERPRO CONNECTION W/ 72" OF CONDUCTOR SLACK STREET LIGHT SINGLE LINE DIAGRAM (N) 2 #10 WIRES (N) 30A FUSE AT MID -POINT OF 48" CONDUCTOR SLACK IN PULLBOX E E E E E E LEGEND FIBER LINE(S) FIBER POWER RUN E GROUND WIRE(S) G COAX CABLE A FUSE & FUSE HOLDER, SIZE AND TYPE AS INDICATED. GROUND ROD (N) STREET LIGHT l0A FUSE AT MID -POINT OF 48" CONDUCTOR SLACK IN PULLBOX (N) STREET LIGHT CONDUCTORS 2#10 (N) (2) TWIN DIPLEXERS (N) (4) 1 /4" COAX CABLES FROM RADIOS TO TWIN DIPLEXERS 6701 6701 FIBER � I cm� �m w (N) (1) FIBER JUMPERS TOLU no FEED EACH ANTENNA/RADIO ry Em w LL m FUTURE FIBER AND m" Ew m CONDUIT UNDER " O° a SEPARATE PERMIT LL ��B�R �kBEFRR �kB&R �kBEF�R FIBER 11X17 BOX FIBER FIBER FIBER FIBER FIBER FIB (UNDER SEPARATE PERMIT) FIBER POC FIBER FIBER FIBER FIBER FIBER FIBER/COAX DIAGRAM RRUS 32 (N) CONDUCTORS G (N) EQUIPMENT L—� E LUMINAIRE (N) STREET LIGHT CONDUCTORS 2#10 (N) (4) 1 /4" COAX CABLES FROM TWIN DIPLEXERS TO ANTENNA (N) (4) 1 /4" COAX CABLES FROM RADIO TO TWIN DIPLEXERS QQQ Q c RET CABLE, ACCESSIBLE THROUGH HANDHOLE. CABLE TIE EXCESS CABLING AT ANTENNA CAGE Q (N) (2) FIBER JUMPERS TO FEED 3 2 Carrier ground wire and ground rod to be labeled if placed in City's electrical box. (N) DI 3 E-3 (N) 6 E-3 2 (N) (4) (N) TERMIN/ (N) #10 WIRE FROG SEE STIR (N)STREE (E) CITY SERVICE POINT SEE CIRCUIT DIAGRAM E CITY SERVICE CONDUCTORS NOTE: CONDUIT FILL CALCULATIONS REQUIRED 1.5" 0 CONDUIT CONTACT ENGINEER IF SMALLER ELECTRICAL AND GROUNDING DIAGRAM D-1 4 CANISTER ANTENNA D-1 6 SG ANTENNA ------------ E �I LUMINAIRE 0 (N) STREET LIGHT CONDUCTORS 11 I w(, 2# 10 & 1 #8 GND I �w w SHROUD 6701 6701 caw PER N.E.C. ARTICLE 250 14 WIRES ROUND #14 WIRES :ROUND FROM ANTENNA TO �ECTED AT GROUND BAR IN NECT SWITCH PER CEC ,ND 800.100(B)(2) 10 WIRES WIRE FROM TERMINAL BLOCK ONNECT VAGO SPLICE CONNECTORS )ISCONNECT 10 WIRES & (1) #10 GROUND ;0 SPLICERS :ONNECT `10 WIRES f0 STREET LIGHT CONDUCTORS AND STREET LIGHT TO OTHER STREET LIGHTS CITY SERVICE CONDUCTORS verizonN/ VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 WALNUT CREEK, CA 94598 MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA 94108 DRAWN BY: APE CHECKED BY: BPM APPROVED BY: LJB REV DATE DESCRIPTION 0 04/03/20 100% CD 1 06/24/20 100% CD REV 1 2 10/29/20 100% CD PLAN CHECK 'QRflF ESS /0. WES B' F t/,p Uj m NO. C64533 CIVIL���__ OF C AL IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT CUPERTINO_CUPER020 (NEAR) 20975 VALLEY GREEN DR CUPERTINO, CA 95014 ELECTRICAL SINGLE -LINE AND GROUNDING DIAGRAM E-2 Conduit Fill Calculation - 1.5" PVC with MaxCell 2-cell 3 1 /8" Conduit Inside Diameter (I.D.): 1.5 in- (N) PG&E TRANSFORMER RATED SMARTPOLE METER verizonN/(FURNISHED &INSTALLED BY Total Inside Area, (TL/4)D' (rlj4)11,5}` - 1.77 in.� PG&E) Allowable fill at 40% (Per CEC)- (1.77)xU_4 = 0.71 in! A A 1.S" PVC Calculated Fil I: Size Area iin.21 Qtv. Total Areaiin.2l co co Fiber*': 1F 0,0544 476 VERIZON WIRELESS 2785 MITCHELL DRIVE, SUITE 9 DUAL IN -LINE FUSE HOLDER ATT Power: #10 0.0243 Z 0.0486 ELEVATION WALNUT CREEK, CA ATT Ground: 48 0.0437 1 D.043 94598 3.06"O Streetlight Power". #8 0.0437 2 D.U874 NICKLE PLATED BRASS PIN TOP VIEW WHITE COLOR M COPPER COLOR Streetlight Ground: #8 0.0437 2 D_0874 PLUNGER SWITCH TCltal: 0.4847 BRASS PIN BRASS PIN NICKLE PLATED c� Total calculated fill is less than 40%a11owable COPPER COLOR WHITE COLOR m0DUS SIDE VIEW All power anc ground conductors Type THVv "WORST CASE SIZE OR QUANTITY SHOWN CONSERVATIVELY, SEE PLANS FOR ACTUAL SIZE / QUANTITY REQUIRE PLAN 4-PIN SOCKET MODUS, LLC 240 STOCKTON ST., 3RD FLOOR SAN FRANCISCO, CA NOT USED 12 FUSE HOLDER 9 CONDUIT FILL 6 SMART METER 3 94108 ERICSSION PSU AC 08 DRAWN BY: APE DIMENSIONS: 2.72" TALL x 10.79" WIDE x 7.09" DEEP CHECKED BY: BPM PHOTOCELL TABLE WEIGHT: 11.46 Ibs APPROVED BY: LJB PHOTOCELL THE PSU IS REQUIRED TO OPERATE THE RRUS ON AC. IF THE RRUS IS INSTALLED OUTDOORS, THE ACCU IS VA& AV] POLE ID CIRCUIT # REQUIRED ALSO REQUIRED, OTHERWISE THE ACCU IS OPTIONAL. THE EQUIPMENT FOR AC POWER SUPPLY IS, (YES/NO) SHOWN FIGURE 1 REV DATE DESCRIPTION 5809 1 NO RSWSeries 0 04/03/20 100% CID 5808 1 NO fit" LED Street Lumtnaire - Small 1 06/24/20 100% CD REV 1 5807 1 NO PnxlluctDwcriptlm two GROUNDING x 7 W 2 I 2 10/29/20 100% CD PLAN CHECK " A_flNG CO IINECTOR Ohl METER 5806 1 NO iheCreeaRSWScncs,�tT.iemgthfmaMsi°Tc=_hrwlegy,w lcruns{ermlhcwati�li.itlesand �_ INTERFACE r rp . {, {I�PBeEUMg-24-5t munici*ities light lhair tesi drht ial sttoets. Wilk the-flrsl maple LED streetlight at rw trh CCT. the RSW � SERVNT 11HL211+ 5805 1 NO ssric: delwers up to 127 LF-W, enhanced visual cumfnrt wnh redaced g:are and high talon cartra:x x Y W 2 5804 1 NO Leading to impra+ed umrall illomirmlion using leap e"rgy_ The RSW Series prarides rwrm, irwitmg dark skylrie,n0f lighting the{ makes goad econanic serum. x{L1 Blattl 5803 1 NO Ajirlkrdor Roadway - Lacal,iCcZlector 0 ° 5802 1 NO __ sa Not.X(111l,tnaYfWN)cafluctors tmm the endesiee to t.e camected 5800 1 NO No [rx EIiCUn2c1 €tritcll !tv ve,l4n,r 6624 1 NO Performance Summary lJtMues Cree Wf a etMae TechneLagr tVEF14• pl,acaCxl I krccptacic lac°tian YES Awxrvbiedin the U,S,A.uI L1.5, and imparted parts AC POWER INTERFACE Ethapty! Up to 127 LPiM 1G76mrnl r :T 141k5t1 PSU 6a _ Cal: Min -mum 70 CRI I-IMC , I(MOK & 50001(1, 89 CRI 12700K, 3000K, 400015 5 5DON11 g_p- CV" 2%UK 7LWra, AMOK, 5000K {1iirI1M1RM �t LlmitedWarranhp'_ 7IOyters r"'} I C+b Ih9L1E 9uCJf y rah •I � [-w.an�mn�brram.R, l[— Nv to 3m4.a} t� Acceswries I20tmrnl�4 i ACCU f IQl ti-mxlut" s:L tisOMASMotd M ul�';°,Mx FIGURE 1 'eRp.. �ESS/0. f PHOTOCELL TABLE 1 1 PSU AC08 5 RECEPTACLE WIRING DIAGRAM 2 ME q Y_ 4, � C�, Util+ty Lahrl4acatiprs Ln - rn = — TESCO DISCONNECT BOX WITH CT AND METER SOCKET _ : i \ 1 /2" STAINLESS STEELyt, 0 =_ * N0. C64533 LIGHT POLE / COLOR: GRAY BANDS dehm=IstT,ajl = CIVIL I DIMENSIONS: 20.5" TALL x 8.75" WIDE x 4.25" DEEP ., .. \-AtW tl�J,re -r .dI-W,10Nq TOTAL WEIGHT: ...... \ drdanng Information STEEL MOUNT [:-,pd.r��tvs.a.11r-r.7� tirf�ul.G^.N PHASE.: 3-WIRE 0 t�F,,,CA BRACKET AND L 0 RSWI a TIT 3NE ij, K7 uL iav N X2 VOLTAGE: 120/240 u ° � AMPACITY: 60 MAX PLATE PrPOW ym1m IMagptlrlg WK pa k VUTJCR1 tuuay� poem Vh4g0t*VF4o;ptxia 00"s BOLT GRND. 2 BOLT PARALLEL CROSS RUN UNIVERSAL PIPE ROD CLAMP SPLICER CLAMP CLAMPS IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS Rsttrs +t❑ I4T 2u61 u 29"Jay 1 61Ew. WQ3vQMF!Wd,rrlumbkOutpw THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED 3 rtull iO,Qa„Ill Type 11 .nry 3304 Llrara 2TOAk 60CR1 Jrwv-sal fl 7..PYl'PNlecct'I 1 aCtpx1ffi Nuu saw.1 U t13, X. or C t a N 75/1.25 PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT DISCONNECT TuRr 2Ne SL So" t2a2Trf EsttrtWwanaaauLulpw Cn�sNllrrgcllr^ah TOP VIEW aN� �.000 Lurorts . m r �t 7. pn racepriza pw ran d nw l 2gm I;bN Ix sal, rq VAH III mcum 3>;tilKADC4a AWE136St Matta —• Fawns cwricc id C. tlhr Rrlar to pages 5 L ► I:r pony, and rim Wm&. I.as,tr xwluas 1/2" STAINLESS 4W PWM=lrasrmxtafP lt7Pt1 IMAN LuRtrraurpal TOP VIEW STEEL BANDS 4MOK MCM W'°yh°'� Him zatim X3 A3 OF AI mRT t .mar ou 1pu: rs pa Tara mte 4.25" 8. 75" sa LIGHT POLE siox.� Fit tadrtemlftALUng:aunu: k-dA cwuaga lan tPx wu '�"° ;�L�r P°" rSg STEEL MOUNT amaw.tmeRl ard CUPERTINO_CUPER020 BRACKET AND _ PLATE "F`•��•""" .12,h"—ham. --'VI U. h"=LI r, 2 HOLE LUG CAST "T" SPLICER 1 BOLT PARALLEL SHUTDOWN "LV1�1 r11c�].[wn.,.•1.,'rrij.ma,awyn�u�r �'S J�lras�,-.•..�_,e,�[wyr rwr�,�M*'w. Gc[aw [p�nw,.'� �rrrn nwrl i,++r�Iw l.Orw,lwlrr ,�. 1p+i„c „R..�rrAM� N o N PG&E SMART CLAMP (NEAR) 20975 VALLEY STEEL MOUNT r' METER GREEN DR BRACKET AND s"utoowN M EATON DISCONNECT PLATE — — — — ® _.Am °'�°'gCREEmr.CUPERTINO, CA 95014 BOX DG222NRB � o 1 /2" STAINLESS STEEL BANDS 0.375 1 1/2"STD PIPE- 4$p ELECTRICAL DETAILS DISCONNECT NIPPLE 1 /2" THREAD SIGNAGE PER SEALING 7/D-2 TAPE LT 1 BOLT PARALLEL FRONT VIEW SIDE VIEW SIDE VIEW FRONT VIEW PIPE CLOAMP CLAMP UNIVERSALPIPECLAMPS E-3 DISCONNECT MOUNTING 10 LUMINAIRE SPECS 7 DISCONNECT 4 MECHANICAL CONNECTION 1 Encroachment Agreement - 20975 Valley Green Dr - CUPER 020 Final Audit Report Created: 2020-12-07 By: Araceli Alejandre (aracelia@cupertino.org) Status: Signed Transaction ID: CBJCHBCAABAAPQJP8NgAIIBSpUbBJ1GVAWNm29kaRruW 2020-12-09 "Encroachment Agreement - 20975 Valley Green Dr - CUPER 0 20" History Document created by Araceli Alejandre (aracelia@cupertino.org) 2020-12-07 - 5:57:20 PM GMT- IP address: 73.170.27.253 Document emailed to Heather M. Minner (minner@smwlaw.com) for signature 2020-12-07 - 6:00:54 PM GMT Email viewed by Heather M. Minner (minner@smwlaw.com) 2020-12-08 - 11:19:30 PM GMT- IP address: 104.143.198.247 &0 Document e-signed by Heather M. Minner (minner@smwlaw.com) Signature Date: 2020-12-08 - 11:20:08 PM GMT - Time Source: server- IP address: 52.39.49.65 Icy Document emailed to Chad Mosley (chadm@cupertino.org) for signature 2020-12-08 - 11:20:10 PM GMT Email viewed by Chad Mosley (chadm@cupertino.org) 2020-12-09 - 0:09:54 AM GMT- IP address: 104.47.73.126 Document e-signed by Chad Mosley (chadm@cupertino.org) Signature Date: 2020-12-09 - 0:10:07 AM GMT - Time Source: server- IP address: 67.164.60.110 Document emailed to Kirsten Squarcia (kirstens@cupertino.org) for signature 2020-12-09 - 0:10:10 AM GMT Email viewed by Kirsten Squarcia (kirstens@cupertino.org) 2020-12-09 - 0:15:35 AM GMT- IP address: 104.47.46.254 &0 Document e-signed by Kirsten Squarcia (kirstens@cupertino.org) Signature Date: 2020-12-09 - 0:15:51 AM GMT - Time Source: server- IP address: 69.110.137.176 Adobei ol)2 Slgl'1 c�rerrrinv Agreement completed. 2020-12-09 - 0:15:51 AM GMT FMIdi Adobe Ob2 Slgl'1 CVrLR INO