BLD-2021-0678 Plans 07/16/21INDEX
ABBREVIATIONS ELECTRICAL NOTES
VICINITY MAP
JURISDICTION NOTES
REV BY DATE COMMENTS
REV A NAME DATE COMMENTS
REV B BP 6/16/2021 Layout altered & added equip. distance to prop. line
REV C LJS 7/9/2021 Layout updated due to FSB.
* * **
* * **
LICENSE GENERAL NOTES
Phuong Devries
07/16/21
07/16/21
BLD-2021-0975
Haley McKee
(E) DRIVEWAY
01' 32'16'
Scale:1/16" = 1'
PROPERTY PLAN
c
Phuong Devries
07/16/21
Front Of House
(E) DRIVEWAY 3' FSB1'-6
"
F
S
B
3' FSB3' FSB3' FS
B
12" SB
1'-6
"
FS
B12" SB12
"
S
B 3' FSB1'-6" FSB1'-6" FSB3' FSB1'-6" FSB1'-6" FSB3' FSB1'-6"
F
S
B
1'-6" FS
B12" setback12" setback12
"
s
e
t
bac
k
3' FSB1 2" SB
12" SB1
2
"
S
B
3' FS
B3' FSB3' FS
B3' FSB1'-6" F
S
B
B
CPitch4/12M
P
1 Pitch4/12M
P
2
Pitch4/12M
P
3
Scale: 3/32" = 1'
SITE PLAN
0 1'10' 21'
LEGEND
MP3
17° (4:12)
212
17° (4:12)
212
Comp Shingle 2 Stories
MP2
19° (4:12)
212
19° (4:12)
212
Comp Shingle 2 Stories
MP1
19
212
19
212
Comp Shingle 2 Stories
#SSTAMPCA
#ESTAMPCA
c
Phuong Devries
07/16/21
S1
SIDE VIEW OF MP3 NTS
STORIES: ROOF AZI PITCH
ARRAY AZI PITCH
MP3
212 17
212 17
Comp Shingle
22x4 @ 24" OC
2x4 @24" OC
RAFTER
C.J.
C
S1
SIDE VIEW OF MP2 NTS
STORIES: ROOF AZI PITCH
ARRAY AZI PITCH
MP2
212 19
212 19
Comp Shingle
22x4 @ 24" OC
2x4 @24" OC
RAFTER
C.J.
B
Scale: 1 1/2" = 1'
STANDOFFS1
#SSTAMPCA
Phuong Devries
07/16/21
#SSTAMPCA
Phuong Devries
07/16/21
LICENSEMODULE SPECS
INV 1
INVERTER SPECS GENERAL NOTES MAIN PANEL SPECS GROUND SPECS
INV 2
INV 3
AC DC
A
B
EGC
GEC
GNDGND
A
L2
L1
EGC
GND
240V
Inverter 1 IND
EGC
DC-
DC+
DC-
DC+
EGC
DC-
DC+
EGC
DC-
DC+
MP 2: 1x9
MP 3: 1x3
GD
PV A POI
1
Voc* = VDC Isc = ADC
Vmp = VDC Imp= ADC1
2
Voc* = VDC Isc = ADC
Vmp = VDC Imp= ADC2
3
Vmp = VAC Imp= AAC
3
#ESTAMPCA
c
Phuong Devries
07/16/21
SOLAR PV SYSTEM
EQUIPPED WITH RAPID
SHUTDOWN
- Address: 817 Cottonwood Dr
OPERATING VOLTAGE = 240V JB-95016040-00
Phuong Devries
07/16/21
LB-130089-10X
Per Code:
CEC 690.31.G.3
Label Location:
(C)(IC)(CB)
LB-050081-10X
Per Code:
CEC 690.13.B
Label Location:
(DC) (INV)
690_53_2017
Per Code:
CEC 690.53
Label Location:
(DC) (INV)
LB-050082-10X
Per Code:
CEC 690.13.B
Label Location:
(AC) (POI)
LB-040007-10X
Per Code:
CEC 690.54
Label Location:
(AC) (POI)
LB-040013-10X Label Location:
(AC)
LB-070005-10X
Per Code:
690.13.B
Label Location:
(DC)(CB)
LB-070039-10X_2017
Per Code:
705.12.B.2.3.b
Label Location:
(POI)
LB_200127_10X
Per Code:
705.12.B.2.3.c
LB-040009-10X
Per Code:
705.12.B.3
Label Location:
(POI)
LB-060046-10X
Per Code:
CEC 690.54; CEC 690.13.B
Label Location:
(POI)
LB-101092-10X
Per Code:
690.56 (C)(3)
Label Location:
RSD Switch
LB-250002-34X
Per Code:
690.56(C)(1)(a)
Label Location:
SolarEdge and,Delta M-Series and,Telsa Inverter
(POI): Point of Interconnection
(M): Utility Meter
(LC): Load Center
(INV): Inverter With Integrated DC Disconnect
(IC): Interior Run Conduit
(DC): DC Disconnect
(D): Distribution Panel
(CB): Combiner Box
(C): Conduit
(AC): AC Disconnect
Label Set
Phuong Devries
07/16/21
YIELD SECURITY
ANTI PID TECHNOLOGY
(APT)
HOT-SPOT PROTECT
(HSP)
TRACEABLE QUALITY
(TRA.QTM)
ANTI LID TECHNOLOGY
(ALT)
Product and
Performance
Warranty
Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY
Higher yield per surface area, lower BOS costs, higher
power classes, and an efficiency rate of up to 19.5 %.
INNOVATIVE ALL-WEATHER TECHNOLOGY
Optimal yields, whatever the weather with
excellent low-light and temperature behavior.
ENDURING HIGH PERFORMANCE
Long-term yield security with Anti LID and Anti PID Technology1,
Hot-Spot Protect and Traceable Quality Tra.Q™.
ZEP COMPATIBLETM FRAME DESIGN
High-tech black Zep CompatibleTM frame, for improved aesthetics,
easy installation and increased safety.
A RELIABLE INVESTMENT
Inclusive 25-year product warranty and 25-year
linear performance warranty2.
STATE OF THE ART MODULE TECHNOLOGY
Q.ANTUM DUO combines cutting edge cell separation
and innovative wiring with Q.ANTUM Technology.
1 APT test conditions according to IEC/TS 62804-1:2015, method B (−1500 V, 168 h)
2 See data sheet on rear for further information
THE IDEAL SOLUTION FOR:
Rooftop arrays on
commercial and
industrial buildings
Q.PEAK DUO BLK-G6+ / SC
330-345
ENDURING HIGH
PERFORMANCE
Į [% / K]+ 0.04 ȕ [% / K] − 0.27
Ȗ [% / K]− 0.36 NMOT [°F] 109 ± 5.4 (43 ± 3 °C)
330 335 340 345
[W]330 335 340 345
[A]10.41 10.47 10.52 10.58
[V]40.15 40.41 40.66 40.92
[A]9.91 9.97 10.02 10.07
[V]33.29 33.62 33.94 34.25
[%]≥ 18.4 ≥ 18.7 ≥ 19.0 ≥ 19.3
[W]247.0 250.7 254.5 258.2
[A]8.39 8.43 8.48 8.52
[V]37.86 38.10 38.34 38.59
[A]7.80 7.84 7.89 7.93
[V]31.66 31.97 32.27 32.57
[V]1000 (IEC) / 1000 (UL) II
[A DC]20 C (IEC) / TYPE 2 (UL)
[lbs / ft2] 50 (2400 Pa) / 50 (2400 Pa)− 40 °F up to + 185 °F
(− 40 °C up to + 85 °C) [lbs / ft2] 75 (3600 Pa) / 75 (3600 Pa)
3 See Installation Manual
Certified
UL 1703
(254141)
Hanwha Q CELLS America Inc.
400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us
MECHANICAL SPECIFICATION
Format 68.5 × 40.6 × 1.57 in (including frame)
(1740 × 1030 × 40 mm)
Weight 47.4 lbs (21.5 kg)
Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass
with anti-reflection technology
Back Cover Composite film
Frame Black anodized aluminum
Cell 6 × 20 monocrystalline Q.ANTUM solar half cells
Junction Box 2.09-3.98 × 1.26-2.36 × 0.59-0.71 in (53-101 × 32-60 × 15-18 mm),
Protection class IP67, with bypass diodes
Cable 4 mm² Solar cable; (+) ≥ 43.3 in (1100 mm), (−) ≥ 43.3 in (1100 mm)
Connector Stäubli MC4; IP68
Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use
of this product.Specifications subject to technical changes © Q CELLS Q.PEAK DUO BLK-G6+/SC_330-345_2019-11_Rev01_NAELECTRICAL CHARACTERISTICS
POWER CLASS
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)MinimumPower at MPP1 PMPP
Short Circuit Current1 ISC
Open Circuit Voltage1 VOC
Current at MPP IMPP
Voltage at MPP VMPP
Efficiency1 Ș
MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2
MinimumPower at MPP PMPP
Short Circuit Current ISC
Open Circuit Voltage VOC
Current at MPP IMPP
Voltage at MPP VMPP
1 Measurement tolerances P MPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2800 W/m², NMOT, spectrum AM 1.5
Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE
At least 98 % of nominal power during
first year. Thereafter max. 0.54 %
degradation per year. At least 93.1 %
of nominal power up to 10 years. At
least 85 % of nominal power up to
25 years.
All data within measurement toleranc-
es. Full warranties in accordance with
the warranty terms of the Q CELLS
sales organization of your respective
country.
Typical module performance under low irradiance conditions in
comparison to STC conditions (25 °C, 1000 W/m²)
TEMPERATURE COEFFICIENTS
Temperature Coefficient of I SC Temperature Coefficient of VOC
Temperature Coefficient of PMPP Normal Module Operating Temperature
PROPERTIES FOR SYSTEM DESIGN
Maximum System Voltage VSYS Protection Class
Maximum Series Fuse Rating Fire Rating based on ANSI / UL 1703
Max. Design Load, Push / Pull (UL)3 Permitted Module Temperature
on Continuous DutyMax. Test Load, Push / Pull (UL)3
QUALIFICATIONS AND CERTIFICATES
UL 1703, CE-compliant, IEC 61215:2016, IEC 61730:2016,
Application Class II, U.S. Patent No. 9,893,215 (solar cells)
200 400 600 800 1000
110
100
90
80RELATIVE EFFICIENCY [%]IRRADIANCE [W/m²]RELATIVE EFFICIENCYCOMPARED TO NOMINAL POWER [%]100
95
90
85
80
75
15 5 2 5200 10
YEARS
98
Q CELLS
Industry standard for tiered warranties*
Industry standard for linear warranties*
*Standard terms of guarantee for the 10 PV companies
with the highest production capacity in 2014 (as at: September 2014)
37.4" (950 mm)
68.5" (1740 mm)
4 × Fastening points (DETAIL A)
Frame
6.06"
(154 mm)
40.55" (1030 mm)
38.6" (981 mm)
1.57" (40 mm)
8 × Drainage opening
0.14" × 3.1" (3.6 mm × 8 mm)
6 × Grounding points ø 0.16" (4 mm)
Label
DETAIL A 0,472" (12 mm)
0.354" (9 mm)1.063" (27 mm)
15.6“ (395 mm)
7.09" (180 mm)
4 × Drainage opening
≥ 43.3" (1100
m
m)
≥ 43.3" (1100
m
m)
Phuong Devries
07/16/21
DC-
DC+
1
GD
·
·
·
·
·
DC1
Phuong Devries
07/16/21
·
·
·
·
·
DC1
DC-
DC+
1
GD
Phuong Devries
07/16/21
TESLA.COM/ENERGY
SOLAR INVERTER
411 mm
660 mm
158
mm
Tesla Solar Inverter provides DC to AC conversion and integrates with the Tesla ecosystem,
including Solar Panels, Solar Roof, Powerwall, and vehicle charging, to provide a seamless
sustainable energy experience.
KEY FEATURES
• Integrated rapid shutdown, arc
fault, and ground fault protection
• No neutral wire simplifies installation
• 2x the standard number of MPPTs for
high production on complex roofs
NA 2021-6-1
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature –30°C to 45°C (–22°F to 113°F)4
Operating Humidity (RH) Up to 100%, condensing
Storage Temperature –30°C to 70°C (–22°F to 158°F)
Maximum Elevation 3000 m (9843 ft)
Environment Indoor and outdoor rated
Enclosure Rating Type 3R
Ingress Rating IP55 (Wiring compartment)
Pollution Rating PD2 for power electronics and terminal wiring
compartment, PD3 for all other components
Operating Noise @ 1 m < 40 db(A) nominal, < 50 db(A) maximum
ELECTRICAL SPECIFICATIONS
MODEL NUMBER 1534000-xx-y 1538000-xx-y
OUTPUT (AC)3.8 kW 7.6 kW
Nominal Power 3,800 W 7,600 W
Maximum Apparent Power 3,328 VA at 208 V
3,840 VA at 240 V
6,656 VA at 208 V
7,680 VA at 240 V
Maximum Continuous Current 16 A 32 A
Breaker (Overcurrent Protection)20 A 40 A
Nominal Power Factor 1 - 0.9 (leading / lagging)
THD (at Nominal Power)<5%
INPUT (DC)
MPPT 2 4
Input Connectors per MPPT 1-2 1-2-1-2
Maximum Input Voltage 600 VDC
DC Input Voltage Range 60 - 550 VDC
DC MPPT Voltage Range 60 - 480 VDC1
Maximum Current per MPPT (Imp)13 A
Maximum Short Circuit
Current per MPPT (Isc)15 A
COMPLIANCE INFORMATION
Grid Certifications UL 1741, UL 1741 SA, IEEE 1547, IEEE 1547.1
Safety Certifications UL 1699B, UL 1741, UL 1998 (US)
Emissions EN 61000-6-3 (Residential), FCC 47CFR15.109 (a)
MECHANICAL SPECIFICATIONS
Dimensions 660 mm x 411 mm x 158 mm (26 in x 16 in x 6 in)
Weight 52 lb3
Mounting options Wall mount (bracket)
3 Door and bracket can be removed for a mounting weight of 37 lb.
4 For the 7.6 kW Solar Inverter, performance may be de-rated to 6.2 kW at
240 V or 5.37 kW at 208 V when operating at temperatures greater than
45°C.
1 Maximum current.
2 Cellular connectivity subject to network operator service coverage and signal
strength.
PERFORMANCE SPECIFICATIONS
Peak Efficiency 98% at 208 V
98.1% at 240 V
98.4% at 208 V
98.6% at 240 V
CEC Efficiency 97.5% at 208 V
97.5% at 240 V
97.5% at 208 V
98.0% at 240 V
Allowable DC/AC Ratio 1.7
Customer Interface Tesla Mobile App
Internet Connectivity Wi-Fi (2.4 GHz, 802.11 b/g/n),
Ethernet, Cellular (LTE/4G)2
AC Remote Metering Support Wi-Fi (2.4 GHz, 802.11 b/g/n),
RS-485
Protections Integrated arc fault circuit interrupter
(AFCI), Rapid Shutdown
Supported Grid Types 60 Hz, 240 V Split Phase
60 Hz, 208 V Wye
Required Number of Tesla Solar
Shutdown Devices per Solar Module
See Solar Shutdown Device
Requirements per Module on page 3
Warranty 12.5 years
TESLA.COM/ENERGY
SOLAR SHUTDOWN DEVICE
The Tesla Solar Shutdown Device is part of the PV system rapid
shutdown (RSD) function in accordance with Article 690 of the
applicable NEC. When paired with the Tesla Solar Inverter, solar
array shutdown is initiated by any loss of AC power.
650 mm 150 mm
125 mm
250 mm
M4 Screw
M8 Bolt
Nail /
Wood Screw
22 mm
ENVIRONMENTAL SPECIFICATIONS
Ambient Temperature -40°C to 50°C (-40°F to 122°F)
Storage Temperature –30°C to 70°C (–22°F to 158°F)
Enclosure Rating NEMA 4 / IP65
ELECTRICAL SPECIFICATIONS
Nominal Input DC Current Rating (IMP) 12 A
Maximum Input Short Circuit Current (ISC) 15 A
Maximum System Voltage 600 V DC
COMPLIANCE INFORMATION
Certifications UL 1741 PVRSS
PVRSA (Photovoltaic Rapid
Shutdown Array)
MECHANICAL SPECIFICATIONS
Electrical Connections MC4 Connector
Housing Plastic
Dimensions 125 mm x 150 mm x 22 mm
(5 in x 6 in x 1 in)
Weight 350 g (0.77 lb)
Mounting Options ZEP Home Run Clip
M4 Screw (#10)
M8 Bolt (5/16")
Nail / Wood screw
RSD MODULE PERFORMANCE
Maximum Number of Devices per String 5
Control Power Line Excitation
Passive State Normally open
Maximum Power Consumption 7 W
Warranty 25 years
PVRSA
RSD Initiation Method Loss of AC power
Compatible Equipment Tesla Solar Inverter
SOLAR SHUTDOWN DEVICE REQUIREMENTS PER MODULE
The following modules have been certified as part of a PV Rapid Shutdown Array (PVRSA) when installed together with the Tesla Solar Inverter and Tesla
Solar Shutdown Devices. See the Tesla Solar Inverter Installation Manual for guidance on installing Tesla Solar Inverter and Solar Shutdown Devices with
other modules.
Brand Model Required Solar Shutdown Devices
Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules
Hanwha Q.PEAK DUO BLK-G5 1 Solar Shutdown Device per 3 modules
Hanwha Q.PEAK DUO BLK-G6+1 Solar Shutdown Device per 3 modules
NA 2021-6-1
Phuong Devries
07/16/21
FLASHING INSERT
ZS COMP DATASHEET 2
Listed to UL 2703 and UL 2582 for Wind Driven Rain
Part #850-1628
SPECIFICATIONS Designed for pitched roofs.
Installs in portrait and landscape orientations.
Engineered for spans up to 72 and cantilevers up to 24.
ZS Comp has a UL 1703 Class A Fire Rating when installed using modules from any
PDQXIDFWXUHUFHUWL¿HGDV³7\SH´RU³7\SH´
Attachment method UL listed to UL 2582 for Wind Driven Rain.
ZS Comp supports 50 psf (2400 Pa) front and up to 72 psf (3450 Pa) rear side design load
rating for Portrait module orientation per UL 2703.
ZS Comp supports 50 psf (2400 Pa) front side and up to 72 psf (3450 Pa) rear side design
load rating for Landscape module orientation.
Engineered for compliance with ASCE 7-05, 7-10, and 7-16 wind load requirements.
Zep wire management products listed to UL 1565 for wire positioning devices.
ZS Comp grounding products are listed to UL 2703 and UL 467.
ZS Comp bonding products are listed to UL 2703.
DESCRIPTION PV mounting solution for composition shingle roofs.
Works with all Zep Compatible Modules.
Auto bonding UL-listed hardware creates structural and electrical bond.
ROOFING SYSTEM SPECIFICATIONS
MOUNTING BLOCK
CAPTURED WASHER LAG
Listed to UL 2703
Part #850-1633
Part #850-1631-002 and #850-1631-004
ZS COMP DATASHEET 3
GROUND ZEP LEVELING FOOT
DC WIRE CLIP HOME RUN CLIP
Listed to UL 1565
Part #850-1510
ARRAY SKIRT END CAP
Listed to UL 2703
Part #850-1511
Listed to UL 2703
Part #850-1613
Listed to UL 2703
Part #850-1608
Listed to UL 2703
Part #850-1606
Listed to UL 2703
Part #850-1586 (Left)
Part #850-1588 (Right)
INTERLOCKSKIRT GRIP
Listed to UL 2703
Part #850-1397
Listed to UL 1565
Part #850-1509
Listed to UL 2703
Part #850-1281
HYBRID INTERLOCK
Phuong Devries
07/16/21
PVRSA Model: ZS Rapid Shutdown Array
(Applicable to ZS Comp, ZS Span, ZS Ramp, and ZS Seam)
Category QIJR, Report Date: 2021-03-05
Table of Essential Elements
Function Manufacturer Model No.
Firmware
Versions and
Checksums
Certification
Standard
PVRSE Mid Circuit
Interrupter (MCI)Tesla MCI-1
15503792 N/A UL 1741 PVRSE
Inverter Tesla 7.6 kW: 15380002
3.8 kW: 15340002
V1, D85CAB80
V1, 8A3CA3F2
UL 1741, 1998
PVRSS/PVRSE
PV Module Hanwha
Q- CELLS
Q.PEAK DUO BLK-G5/SC315
Q.PEAK DUO BLK-G5/SC320
Q.PEAK DUO BLK G6+/SC330
Q.PEAK DUO BLK-G6+/SC335
Q.PEAK DUO BLK-G6+/SC340
Q.PEAK DUO BLK-G6+/SC345
N/A UL 1703
Interlock Tesla
ZEP 850-1613-001
ZEP 850-1388-001
ZEP 850-1281-001
N/A UL 2703
Ground Zep Tesla ZEP 850-1511-001
ZEP 850-1172-002 N/A UL 467
UL 2703
DC Wire Clip Tesla ZEP 850-1509-001
ZEP 850-1448-001 N/A UL 1565
Homerun Wire Clip Tesla ZEP 850-1510-001 UL 1565
PVRSA Initiator1
(See installation
requirements below)
Non-Specific N/A N/A N/A
1 Dedicated PV system AC circuit breaker or AC disconnect switch, labeled per NEC 690.12 requirements.
2 Applies to variations of this part number with suffix of two numbers and one letter..
Note: PVRSA installation requirements may reduce the effective equipment and component ratings below the individual
equipment and component PVRSE ratings in order to achieve PVRSA shock hazard reduction requirements.
PVRSA Installation Requirements
Max System Voltage 600 Vdc
Max Array Internal Voltage After Actuation 165 Vdc (cold weather open circuit)
Max Series-Connected Panels between MCIs:3
Other Installation Instructions:
1. An MCI must be connected to one end of each series string or sub-array string.
2. Verification that MCIs are installed with 3 or fewer modules between MCIs shall be documented for
inspection, by voltage measurement logs and/or as-built string layout diagrams.
3. The dedicated PV system AC circuit breaker or PV system AC disconnect switch shall serve as the PVRSA
initiator and shall be sized and installed in accordance with NEC requirements. The specific part shall be
identified on the as-built system drawings.
Certification Mark of UL on the installation instructions is the only method provided by UL to identify products
manufactured under its Certification and Follow-Up Service. The Certification Mark for these products includes
the UL symbol, the words "CERTIFIED" and "SAFETY," the geographic identifier(s), and a file number.”
PVRSA Model: Solarglass Roof Rapid Shutdown Array
Category QIJR, Report Date: 2021-03-05
Table of Essential Elements
Function Manufacturer Model No.
Firmware Versions
and Checksums
Certification
Standard
PVRSE Mid Circuit
Interrupter (MCI)Tesla MCI-1
15503792 N/A UL 1741 PVRSE
Inverter Tesla 7.6 kW: 15380002
3.8 kW: 15340002
V1, D85CAB80
V1, 8A3CA3F2
UL 1741, 1998
PVRSS/PVRSE
PV Module Tesla SR60T1 N/A UL 61730
Diode Harness Tesla SRDTH N/A UL 9703
PV Wire Jumper(s) Tesla
SR-BJ2X
SR-BJ3X
SR-BJ4X
SR-BJMini
N/A UL 9703
Pass-Through Box Tesla SRPTB-4 N/A UL 1741
PVRSA Initiator1
(See installation
requirements below)
Non-Specific N/A N/A N/A
1 Dedicated PV system AC circuit breaker or AC disconnect switch, labeled per NEC 690.12 requirements.
2 Applies to variations of this part number with suffix of two numbers and one letter.
Note: PVRSA installation requirements may reduce the effective equipment and component ratings below the individual
equipment and component PVRSE ratings in order to achieve PVRSA shock hazard reduction requirements.
PVRSA Installation Requirements
Max System Voltage 600 Vdc
Max Array Internal Voltage After Actuation 165 Vdc (cold weather open circuit)
Max Series-Connected Panels between MCIs:10
Other Installation Instructions:
1. An MCI must be connected to one end of each series string or mounting plane sub-array string.
2. Verification that MCIs are installed with 10 or fewer modules between MCIs shall be documented for
inspection, by voltage measurement logs and/or as-built string layout diagrams.
3. The dedicated PV system AC circuit breaker or PV system AC disconnect switch shall serve as the PVRSA
initiator and shall be sized and installed in accordance with NEC requirements. The specific part shall be
identified on the as-built system drawings.
Certification Mark of UL on the installation instructions is the only method provided by UL to identify products
manufactured under its Certification and Follow-Up Service. The Certification Mark for these products includes
the UL symbol, the words "CERTIFIED" and "SAFETY," the geographic identifier(s), and a file number.”
Phuong Devries
07/16/21