Loading...
19900 SCB MSP - stamped plans Community Development Department Planning Division — Cupertino * V V I f V V1� f r r f]I f CUPERTINO APPROVED Case# S-2020-001 u ;0 :4 t) 0 a A 1,I Application Number(s) Approval Body: Director/Staff Approva I Date 12/11/20 Signature Gian Paolo Martire Case Manager Index Introduction Section A: Submittal Approval Process Pg. 2 Section B: General Specifications I Section C: Signage Pg. 3 Section D: General Conditions Pg. 4 Section E: Prohibited Signs I Section F: Maintenence Pg. 5 Typical Tenant/Occupant Sign Allowances, Conditions & Sizing Pg. 6 Typical Tenant Sign Type Exhibits Pg. 7 Monument Sign Pg.11 Sign Vendor / Designer Pedestrian Level Blade Signs Pg. 12 Pacific Neon Co.2939AccademyWay Window / Door Graphics Pg. 13 Sacramento, CA 95815916.927.0527 Building Elevations with Sign Exhibits Pg. 14 Contact:John Richardsonwww.pacificneon.com Site Plan / Sign Locations Pg. 15 Sign Allowance Matrix Pg. 16 Property Address 19900 Stevens Creek Boulevard Cupertino, CA 95014 REV.5.8.20 6.25.20 9.23.20 10.8.20 Community Development Department Planning Division — Cupertino r IF 'CUPLRTIN4 19906ASM& Creek Shopping Center Introduction: SECTION A: SUBMITTAL &APPROVAL PROCESSES ESTABLISHED �020-(l This document establishes guidelines and criteria for the design, . Case # --Efi2btC�r�C (s)oA,_IIP,Apd implementation and regulation of Tenant/Occupant signage for 19900 1. Planning Preliminary Review QQ Application Numbers) Cupertino, CA 95014 Stevens Creek Shopping Center in Cupertino California.This sign program Prior to submittal to Landlord,Tenant shall complete a prliminary NEON is to establish sign parameters for current and prospective review with the City of Cupertino PLannin staff b sending a Approva I Body: Director/StafF y p g y g 12/11/20 Tenant/Occupant in order preserve and enhance the appearance of the request to planning@cupertino.org for permission in writing to Approva I Date building and the integrity of the architectural design.The objectives are to proceed with other submittals. MP BUILDING SIGNAGE CRITERIA 2939Sacramento,California Signature o I encourage high quality and unique signage,which is an integral part of Sacramento,California 95815 the architecture of the building using a consistent and uniform sign 2. Submittal to Landlord Case Manager Tel 916.927.0527 standard,and to maintain the aesthetic quality of the property along with Prior to sign fabrication and application for City approval of permits, Fax 916.927.2414 April 2020 the community standards of Cupertino,California.The intent of these each Tenant/Occupant shall submit to the Landlord for approval one www.pacificneon.com criteria is to insure that Tenant/Occupant signage on this property is set of detailed design and shop drawings including the following designed and executed in a manner which will achieve these objectives Project No: 19-0928-07 while providing appropriate identification of Tenant/Occupant's a. Elevation of storefront illustrating the proposed sign design and Account PROJECT DIRECTORY businesses,including incorporation of corporate identification where all dimensions as they relate to the storefront elevation of Executive: John Richardson applicable.The design of all graphics will be carefully considered in Tenant/Occupant's premises including fully dimensioned Tenant relation to the site architecture and landscaping,as well as to the specific frontages and dimensioned site plan with Tenant and building Project: City of Jurisdiction context of the location within the project. frontages;Fully dimensioned and scaled sign shop drawings.Sign 19900 Stevens Creek elevation must be rendered in color and must specify exact Shopping Center City of Cupertino The design,fabrication,installation and maintenance of all signs,including dimensions(including line spacing),copy,layout,materials,colors, 10300 Torre Ave. but not limited to style and placement of lettering,size,color,materials method of attachment,illumination,electrical and all other details Address: Cupertino,CA 95014 and methods of illumination shall be subject to the prior written approval pertinent to the sign construction,as well as all sign area square 19900 Stevens Creek Boulevard Planning Division of the Landlord as provided in this criteria.Any installed non-conforming footage calculation(s) in compliance with this criteria. Cupertino,CA 95014 Attn: Ellen Yau or unapproved sign,or non-maintained sign must be brought into b. Sign section detail through the letter and/or logo shall show the Associate Planner conformance or removed at the non-conforming Tenant/Occupant's dimensioned projection of the face of the letter and/or logo Drawn By: William Dickson EIIenY@cupertino.org expense. and method/specification of illumination. Letters and/or logo sign Date: 4.20.20 (408) 777-1360 details must be accurately dimensioned including line spacing. Revision: 9.23.20 c. Approval or disapproval of sign submittals shall remain the sole right Sign Company of the Landlord or his chosen representative. If submittals are disapproved,then Tenant/Occupants must submit revised plans until Pacific Neon Co. Landlord's approval is obtained. Attn:John Richardson 2939 Academy Way 3. Formal City Submittal Customer Approval: Sacramento,CA 95815 A full set of final plans must be approved and stamped by the Phone (916)927-0527 Landlord prior to permit application or sign fabrication. Following Email:john.richardson@pacificneon.com Landlord's approval of the proposed signage,Tenant/Occupant or his U.L.Listed aagent must submit an application to the City of Cupertino for all Signs to be manufactured to U.L.Specifications and will g pP y p bear the U.L.Label(s).The sign is intended to be installed Developer permits for fabrication and installation by a licensed and bonded in accordance with the requirements of Article600ofthe National Electrical Code and/or other applicable local codes. Sign contractor. This includes proper grounding and bonding of the sign. 19900 Stevens Creek Blvd., LLC Electrical Circuits Attn: Nathan Ungt a. Each Tenant/Occupant shall be responsible for the fulfillment of all Customer to provide primary dedicated electricalcircuit(s) 800 West 6th Street,Suite 600, Los Angeles,CA 90017 with a separate ground to the electrical panel.L.E.D. 9 requirements of these Criteria and of government agencies with Electronics to have a separate dedicated 120Vcomplete T(213)683-0500 D(213)270-6221 F(213)607-7821 jurisdiction and a roved s eCIfICatI0n5. circuit(No shared neutral).common ground to electrical 1 pp p panel acceptable. b. All City coordination with respect to approvals and permits for signs Copyright 02016 and their installation shall be obtained by the Tenant/Occupant or his All print and electronic art remains the sole,copyrighted Representative,at his SOIe expense. property of Pacific Neon Company and are not to be p p distributed,copied,e-mailed or transferred in any way c. Any changes requested by the City of Cupertino regarding design without prior written release from Pacific Neon Company. or intent must be also cleared by Landlord before resubmittal to City. California Title 24 compliant d. The Landlord reserves the right to revise the Criteria in accordance with the City of Cupertino Sign Code Ordinance.These Criteria may be revised at any time if so required by any government agency 19900 Stevens Creek Shopping Center I Tenant/Occupant Sign Criteria (cont.) Community Development Department Plannin Division—Cupertino ha�inAq�PRC) D isdiction over ts contents. 7. Power for the Tenant/Occupant signage shall be provided by the lineal building frontages of each Tenant/Occupant's leased space. �CUPLRTIN4 A Tenant/Occupant's electrical panel to a junction box at all sign ESTABLISHED 1946 Case # 4. &@P"a80gommencement locations.Power hookup shall be the responsibility of the Each Tenant is allowed(1) illuminated sign with a mininum (20)sq.ft. P A WOW W&V q is sign contractor shall not be permitted to Tenant/Occupant. signage allotment regardless of Tenant frontage.No single tenant sign commence installation of the exterior sign unless all of the following area to exceed(200)sq.ft.,regardless of leased frontage. NEON Approval Body: DiFg�tt�q'1yh3jb-Wen met: 8. Tenant/Occupant signs will be no larger than the specifications Approval Date a. �,��rq� c�set of final drawings reflecting the Landlord's and the outlined in this criteria. Tenants with interior pedestrian corridor entrances are allowed(1)D/F pp ! �nnrn inl chnll kn Qbtaipiad from ogch party non-illuminated, pedestrian blade sign within walkway/breezeway area. 2939 Academy way Signature CtlianTk6ff hotNst receive the sign installer's and/or sign 9. All signs are to be positioned so as to be proportional to the area Please refer to section PEDESTRIAN LEVEL BLADE SIGN (Building Sacramento,California 95815 man gl;tWgA,j�,9rti icate of Insurance and Business License. upon which they are placed,as well as to comply with the square Interior)on following page for definitions and specifications for these sign Tel 916.927.0527 c. The Landlord must receive and approve the sign installer's and/or footage limitations.They should also be centered at the appropriate types. Fax 916.927.2414 sign company's schedule for installation of signage. location on the elevation to be balanced with the buildings as a www.pacificneon.com whole(not necessarily centered on the Tenant/Occupant space).The Signage Size Restrictions 5. Modifications appropriate location for all signage shall be coordinated with the Project No: 19-0928-07 In the event Tenant/Occupant wishes to change its exterior sign Landlord. Tenant building signs must not exceed 80%of the vertical height of the Account anytime during the term of its lease,then Tenant/Occupant must architectural building fascia nor 70% of the width of the leased tenant Executive: John Richardson comply with the requirements set forth herein and any future 10. No signs shall extend above facade or architectural screen. frontage.Vertical architectural fascia is typically described as the building modifications,revisions or changes which have been made to the wall area located above the window mullion and top exposed edge of the Project: criteria for the property after the execution of its lease agreement. 11. Fasteners,anchors or other securing elements shall not be roofline of a given building wall at the tenant's lease location.Signs 19900 Stevens Creek visible.All fasteners shall be resistant to corrosion. located on architectureal design screens,the vertical architectural area of Shopping Center the screen would be above the canopy and to top edge of the architectural SECTION B: GENERAL SPECIFICATIONS & 12. Installation shall be weather-tight with appropriate use of flashings, screen. Address: REQUIREMENTS sealants and other building materials,as may be required. 19900 Stevens Creek Boulevard Actual Tenant sign sizes may be less than the maximum values listed as Cupertino,CA 95014 1. All signs shall be reviewed for conformance with these guidelines 13. Tenant/Occupant shall perform installation and other work required dictated by architectural building conditions,and square footage and overall design quality.Approval or disapproval of sign submittals herein at Tenant/Occupant's sole cost and expense. allowances. Drawn By: William Dickson shall remain the right of the Landlord and/or the City of Cupertino. Date: 4.20.20 14. No other signage except that described herein is permitted. EXTERIOR BUILDING SIGNS Revision: 9.23.20 2. All electrical signs shall bear the UL label and be visible from pedestrian level.Signs must be constructed and installed to meet or 15. Tenant/Occupant will be responsible for patching and repairing Face Lit& Halo Lit Pan Channel Letters exceed all applicable codes and City requirements. Per City of (depending on inspection of damage by Landlord)of canopy to Cupertino,a building permit issued by the city shall be obtained original condition upon removal of any signage installed by All Tenant building signs must be individual,internally illuminated letters prior to the erection of any business identification sign. Tenant/Occupant. and/or cloud shaped pan channel logo cabinets. For visual graphic consistency,all sign elements(logo/letters) must be mounted to graphic Customer Approval: 3. Sign content shall be limited to the Tenant/Occupant's name and offset outline backer panels to obscure/hide raceway cabinet structure.All primary graphic logo unless specifically provided for herein. SECTION C: SIGNAGE signs must conform to City of Cupertino building and electrical codes. Construction and installation of signs must be executed by licensed and U.L.Listed 4. Notwithstandingthe following Sin Provisions,Tenant/Occupants ants SIGN AREA MEASUREMENT bonded sign contractors only. Paint finishes to be automotive quality or bear thns toe U1.Labe el(s).red sign U.L.intended one and will 9 9 P 9 Y q Y bear the U.L.Label(s).The sign is intended to be installed may utilize standard corporate logos and/or prototypical signage better,exhibiting no runs,drips,orange peeling or other defects.LED in accordance with the requirements of Article600ofthe National Electrical Code and/or other applicable local codes. graphics, if established as recognizable company or corporate trade Total Tenant/Occupant sign area to be calculated by creating rectangles to modules to be spaced to exhibit no hot spots.Construction of pan channel Thisincludes proper grounding and bonding of the sign. mark or used in a majority of the Tenant/Occupant's stores,subject to encapsulate similar sign graphic elements such as word groupings and cabinets to be weathertight with no visible light leakages. Electrical circuits approval by the City of Cupertino. logos,calculating the areas of those rectangular elements and adding Customer to provide primary dedicated electricalcircuit(s) with a separate ground to the electrical panel.L.E.D. those areas together. Please refer to section "Tenant/Occupant Sign Construction & Design Guidelines: Electronics to have a separate dedicated 120Vcomplete 5. All signage on the building shall be internally illuminated individual Allowances&Conditions" for additional specifications and example.Any pacelacc shared neutral).common ground to electrical panel acceptable. channel letters or logos. No cabinet signs shall be permitted except exceptions or deviations to this standard method of calculation shall be All Tenant Signs Copyright 02016 for logos and graphics which contain square design elements. subject to the review by the Landlord and the City of Cupertino. Due to building wall/fascia conditions concerning electrical access and for All print and electronic art remains the sole,copyrighted Si na a illumination shall not include flashing,moving or visual graphic consistency,all sin elements to o/letters must be property d,Pacific Neon Company and are not to be 9 g 9 9 9 P Y 9 ( 9 ) distributed,copied,e-mailed or transferred in any way scintillating effects. SIGN AREA ALLOTMENT mounted to graphic flat cut-out(F.C.O.)offset outline backer panels to without prior written release from Pacific Neon Company. obscure/hide raceway cabinet structure. No pan channel letters or logos California Title 24 Compliant 6. Pan channel letters/logo are to be defined as individual channel This property is located within the Heart of the City Special Area(HOC) will be allowed to be attached directly to face of raceway cabinets without letters or as connected channels that may be composed of and thereforehas additional sign area than what the Sign Ordinance offset outline backer panels to obscured/hide raceway cabinet structure. script letters with connected serifs,or as non script letters that are normally allows.The Heart of the Clty(HOC)allows for commercial retail connected by heavy outlines into an integrated shape. development allows 1.5 sq.ft.of sign area per 1 lineal foot of store Tenant Signs Mounted on Architectural Metal Screen Facade Sheet No. frontage allowances.Total Tenant/Occupant sign area is based upon the In order to prevent unnecessary damage to architectural metal screen and 19900 Stevens Creek Shopping Center I Tenant/Occupant Sign Criteria (cont.) Community Development Department Plannin Division—Cu ertino to mini ize enpetrations intd screens,tenants should design signs utilizing copy must be dimensional with a depth no less than 1" and mounted on �CUPLRTIN4 only(1)PUFC Q14W access.Word groupings and logo cabinets to offset outline F.C.O.backer panels to minimize the number of attachment 8. Upon termination of lease,all window signs must be removed at ESTABLISHED Case # bridg 0e@b Qther with 5/8" rigid conduit tubes,located within penetrations into building facade.Regardless of construction method,both Tenant/Occupant's expense.Glazing must be returned to original orlW- ar&Wgc L.t o MeLdl screen and painted to match screen non-illuminated and illuminated letters must adhere to the same sign area condition.If glazing cannot be returned to original condition, color.Tenants must submit detailed design and construction details from restrictions. Tenant/Occupant is required to provide replacement at NEON Approval 13odysiqDfi46&8FrAlg ng exact placement of attachment anchors,number Tenant/Occupant's own expense. of antll ,f of penetration for electrical access,and location of TENANT PANELS ON MONUMENT SIGN Approval Dateolor+rir� hririnoc /if�nnlir�hlo\in roles+inn+ +l,o architectural sidin DOOR GRAPHICS/HOURS/ADDRESS g 2939 Academy Way Signature Qldt1$riahA6cM4g@6 submitted for approval must be to scale with sign Landlord reserves the right for tenant sign placement on existing Sacramento,California 95815 design i 4g4t. ,exact placement on ui ing elevation. freestanding signs according to tenant lease agreements,which includes 1. All Tenant/Occupants should have business name/logo located is Tel 916.927.0527 location of sign(s),design,content and size. single door or right side of double doors(or both doors).Graphics are Fax 916.927.2414 Tenant Signs Mounted on Concrete Fagade preferred to be White vinyl film applied first surface to glazing. www.pacificneon.com In order to prevent unnecessary damage to concrete facades,tenants PEDESTRIAN LEVEL BLADE SIGN (Building Interior) Graphics must not exceed 20/o of total door glazing area. should design signs utilizing(1)point for electrical access for each word 2. All Tenant/Occupants should have hours of operation clearly Project No: 19-0928-07 group/logo(if applicable).Word groupings and logo cabinets are not Tenant is allocated(1)D/F non-illuminated blade sign within the displayed either on door or sidelight glazing. Lettering should be Account allowed to use conduit tubes to bridge between raceway cabinets.Tenants pedestrian corridor located within the building as a standard wayfinding White vinyl film applied first surface to glazing. Executive: John Richardson must submit detailed design and construction details from sign contractor sign,directing customers to office/shop entrance. Blade signs are illustrating exact placement of attachment anchors,number of anchors standardized using specified hardware,face backgrounds and colors as set 3. Graphics should contain imagery or copy pertaining to business and Project: and point of penetration for electrical access.All drawings submitted for forth on examples page.Tenants may use logos and typography associated are subject to design review by Landlord. 19900 Stevens Creek approval must be to scale with sign design illustrated with exact with business identity.No other advertising or graphics are allowed.All Shopping Center placement on building elevation. graphics to be White vinyl film on black field,as specified in MSP example LANDLORD DESIGN ALLOWANCES/APPROVALS and documentation. Address: Universal Sign Design Conditions Landlord reserves the right for such allowances according to tenant lease 19900 Stevens Creek Boulevard WINDOW SIGNS/GRAPHICS aggreements,which includes location of sign(s),design,content and size. Cupertino,CA 95014 1. Pan channel letters and logos must be fabricated aluminum All sign designs and color schemes are subject to approval by Landlord an channel construction with interior illumination provided b LEDs. 1. Window graphics are permitted for sidelights,side windows and Drawn By: William Dickson P P Y and the City of Cupertino,who reserve the right to change or modify No exposed LEDs will be allowed. doors as outllined in MSP. designs to conform or maintain design standards in order to compliment Date: 4.20.20 o 2. Faces and returns to have painted or architectural 2. Graphics and/or copy to be limited to cover no more than 20/o of building architecture. Revision: 9.23.20 brushed metal finishes.Painted finishes to have professional the total window area. application with automotive quality paints. SECTION D: GENERAL CONDITIONS 3. Graphics should contain imagery or copy pertaining to business. compliment but must com table be acceptable, graphics may y p , p 3. LEDs to be sufficiently spaced to prevent uneven or light source Decorative g 1. The fabricator may make recommendations and/or changes to the acrchitecture of building. Hand-painted,permanent signs may be Customer Approval: segmentation of modules when viewed at night. details as shown on the drawings provided Landlord approves such acceptable,but design must be authorized and contractor's qualification may be subject to review by Landlord prior to execution recommendations in writing prior to shop drawings or fabrication of . 4. Logos can be cloud shaped pan channel cabinets but square or prototypes or samples. rectagular logos are strongly discouraged unless it is relevant or 4. Signs may be computer cut vinyl film and/or digitally printed vinyl Signslto be manufactured to U.L.Specifications and will integral to logo graphic. film with U.V.inks or U.V.film overlays.Signs digitally printed with 2. All electrical signs shall be UL compliant and carry the certified and bear the U.L.Label(s).The sign is intended to be installed registered UL label affixed to sign cabinet in a lace where it is in accordance with the requirements of Article600ofthe faded graphics shall be removed or replaced at Landlord's discretion. 9 9 p National Electrical Code and/or other applicable local codes. 5. Hidden raceways to be self contained,housing wiring and low Decorative graphics may be acceptable,but must compliment visible at pedestrian level. Thisincludes proper grounding and bonding of the sign. voltage electronic power supplies.All raceways must be no more than acrchitecture of building. Hand-painted,permanent signs may be Electrical circuits 3" deep and all exposed surfaces must be painted to match fascia acceptable,but design must be authorized by Landlord and 3. The sign contractor shall be responsible for the fulfillment of all the Customer to provide primary dedicated electricalcircuit(s) with a separate ground to the electrical panel.L.E.D. color.All housing structures and electrical connections to be contractor's qualifications may be subject to review by Landlord prior requirements and specifications,completing the installation in a Electronics to have a separate dedicated 120Vcomplete circuit(No shared neutral).Common ground to electrical weatherproof and compliant with State,City and U.L.electrical to execution. workman-like manner,and cleaning up,patching and painting any panel acceptable. standards and manufacturing/installation methodology. surfaces damaged by the installation to original building Copyright©2016 5. Paper,hand-painted holiday signs or temporary signs are strictly specifications. All print and electronic art remains the sole,copyrighted 6. All sign designs and color schemes are subject to approval b prohibited. property d,Pacific Neon Company and are not to be g 9 1 pp y p distributed,copied,e-mailed or transferred in any way Landlord and the City of Cupertino,who reserve the right to change 4. All sign fabrication work shall be of excellent quality.All logo images without prior written release from Pacific Neon Company. or modify designs to conform or maintain design standards in order 6. Graphics that are perceived as abusive,inflamatory,or obscene by and type styles shall be accurately reproduced. Lettering that California Title 24 Compliant to compliment building architecture. community standards are strictly prohibited,and are subject to approximates typestyles shall not be acceptable. Landlord reserves immediate removal at Tenant/Occupant's expense. the right to reject any fabrication work deemed to be below Non-Illuminated Letters standard. 7. All window graphics are subject to review and approval at Landlord's discretion.Violation of guidelines will require removal , Tenants may be alllowed non-illuminated secondary letters if construction 5. Signs must be made of durable rust-inhibited materials that are prohibits the letter characters from internal illumination. Non-Illuminated of window graphics at Tenant/Occupant's own expense. appropriate and complimentary to the building. 19900 Stevens Creek Shopping Center I Tenant/Occupant Sign Criteria (cont.) Community Development Department F_ Planning Division — Cupertino ,��ppp `'C��� 3. Landlord reserves the right to periodically hire an independent �C V PLRTIN4 6. Finis!WRAW�netal shall be free from oil canning and 10. Sign which emits odor,noise or visible matter other than light. electrical engineer at Tenant/Occupant's sole expense,to inspect the ESTABLISHED 1946 Ca se # Rio 2oLoe1 f inishes shall be free of dust,ripples,weld marks, installation of all Tenant/Occupant's signs.Tenant/Occupant will be e uniform surfaces 11. No person shall exhibit,post or display or cause to be exhibited, required to have any discrepancies and/or code violations corrected Aconforming to the thighest standards of the industry. posted or displays upon any sign,anything obscene,indecent or at Tenant/Occupant's expense.Landlord may correct any code NEON Approva I Body: Director/Staff immoral nature or unlawful,as determined in the sole discretion of violations,requests for sign removals,or discrepancies not corrected 7. �Sjlg �gg lighting should be concealed and light leaks will not be Landlord. within ten(10)days of notice,at Tenant/Occupant's sole expense, Approval Date PsYm,t o including an overhead charge of 10%. 2939 Academy way Signature Gian Paolo Martire 12. No sign shall be installed,or located so as to prevent free ingress to Sacramento,California 95815 8. All n&W$"A%,qainted with the highest quality automotive or egress from any door. 4. Contractors installing signs are to be qualified,insured and licensed Tel 916.927.0527 polyurethane paint(preferably Matthews Paint,or equal quality by the State of California and are to have a current City business Fax 916.927.2414 alternative),unless otherwise specified.Tenant/Occupant is required 13. External displays(other than holiday decorations)which consist of license. www.pacificneon.com to execute a sign painting application that yields the longest life with unshielded light bulbs,open or strings of open light bulbs. the least likelihood of paint fading and peeling.Paint must withstand Project No: 19-0928-07 exterior weather conditions,and be sprayed to a smooth finish, not 14. Signs displaying pricing of any kind. Account brushed on. Executive: John Richardson 15. Temporary signs of any nature used or installed without 9. Details on drawings indicate a design approach for sign structures Landlord's approval in writing,and in accordance with City Project: but do not necessarily include all fabrication details required for the regulations. 19900 Stevens Creek complete structural integrity of the signs,including consideration for Shopping Center static,dynamic and erection loads during handling,erecting and 16. Unprofessional hand-lettered sign in public view from the storefront service at the installed locations,nor do they necessarily consider the are prohibited. Address: preferred shop practices of the individual general sign contractors. 19900 Stevens Creek Boulevard Therefore,it shall be the responsibility of the fabricator to perform 17. Absolutely no signs are permitted to be taped to the storefront or any Cupertino,CA 95014 the complete structural design of the signs and to incorporate all the other visible surface. reasonable safety factors to protect the Landlord and sign fabricator Drawn By: William Dickson against public liability. 18. Any sign that is not in conformance with this criteria. Date: 4.20.20 Revision: 9.23.20 SECTION E: PROHIBITED SIGNS & RESTRICTIONS 19. No simulated materials(i.e.,wood grained plastic laminates)or wall coverings. The following instances are provided as examples of prohibited signage applications and may not exhibit all possible conditions.Signs prohibited 20. Excessively bright or garish signs by Landlord that do not conform to the Master Sign Program are not limited to those set forth below. Customer Approval: SECTION F: MAINTENANCE 1. Signs which move,swing,rotate,flash,blink,scintillate,fluctuate or have animated light areas. 1. Tenant/Occupant shall maintain his sign in good working order to U.L.Listed include replacement of damaged or burned out LED lighting Signs to be manufactured to U.L.Specifications and will nstalled 3. Off-Premises signage. at Tenant/Occupant's sole cost and expense. In the event Landlord inaccordar the L.Label(theres).The requirements ntsofedtle6o be00ofthe p in accordance with the requirementr of Article 600 of the notifies Tenant/Occupant of an existing defect and Tenant/Occupant National Electrical Code and/or other applicable local codes. 4. "A"frame signs prohibited without Landlord approval,and in fails to cure said defect within ten(10)days after notification, This includes proper grounding and bonding of the sign. accordance with Citypolicy. Electrical circuits p y Landlord may cause the defect to be repaired.Tenant/Occupant customer to provide primary dedicated electricalcircuit(s) hereby agrees to reimburse Landlord for the cost of any such repairs with a separate ground to the electrical panel.L.E.D. 5. Signs using exposed fastenings. Electronics to have a separate dedicated 120Vcomplete within ten days after the receipt of an invoice setting forth those circuit(No shared neutral).common ground to electrical costs incurred by Landlord,plus an overhead charge of 10% panel acceptable. 6. Paper,cardboard,cloth,form core,gatorboard, inflatable or minimum plus any damages resulting from lost income. Copyright©2016 styrofoam signs,stickers or decals,painted lettering or decals hung All print and electronic art remains the sole,copyrighted property of Pacific Neon Company and are not to be on or behind storefronts. distributed,copied,e-mailed or transferred in any way 2. Upon termination or expiration of the lease,Tenant/Occupant hereby without prior written release from Pacific Neon Company. 7. Flying signs such as blimps or kites designed to be kept aloft by agrees to remove his sign and repair any holes or damage to the California Title 24 Compliant mechanical,chemical or hot air means. fascia and restore the fascia to its original condition at Tenant/Occupant's cost and expense to Landlord's sole satisfaction 8. Stationary or walking sandwich boards or costumed or with three(3)days of expiration of term or early termination of non-costumed persons shall not be utilized for advertising outside of Tenant/Occupant's lease.If Tenant/Occupant does not repair the wall Tenant/Occupant's premises. surface to Landlord's sole satisfaction,then Landlord reserves the Sheet No. right to perform the repairs at Tenant/Occupant's expense. 5 9. Balloons,flags or marketing tents. 19900 Stevens Creek Shopping Center I Tenant/Occupant Sign Allowances & Area Calculation Methods Community Development Department Planning Division — Cupertino CUPERTINO APPROVED ESTABLISHED Case# S-2020-001 Application Number(s) NEON Approval Body: Director/Staff Approva I Date 12/11/20 2939 Academy way Signature Gian Paolo Martire 14 TOTAL SIGN WIDTH Sacramento,California 95815 Cas Manager r LOGO PAN CHANNEL NOT TO EXCEED 70%OF ALLOCATED TENANT LEASED FRONTAGE Tel 916.927.0527 l l Fax 916.927.2414 l www.pacificneon.com TOTAL SIGN HEIGHT l ——— --------------------------- NOT TO EXCEED 80% Project No: 19-0928-07 OF ALLOCATED TENANT FASCIA HEIGHT l Account (PLEASE REFER TO Executive: John Richardson SHEET 3 UNDER SIGNAGE SIZE RESTRICTIONS FOR l Project: TYPICAL DEFINITION OF l 19900 Stevens Creek VERTICAL ARCHITECTURAL l ___ _ ____ ____ __ __ Shopping Center FASCIA) l l I Address: l OFFSET OUTLINE PAN CHANNEL 19900 Stevens Creek Boulevard I __ ___ I F.CO.BACKERPANEL LETTERS Cupertino,CA 95014 Drawn By: William Dickson OFFSET OUTLINE SIGN AREA(REPRESENTED BY BLUE AREAS WITH DASHED LINES) Date: 4.20.20 F.C.O.BACKER PANEL CALCULATED BY CREATING CONTINUOUS RECTANGULAR SHAPES(UP Revision: 9.23.20 TO 12 SIDES) ENCAPSULATING SIGN GRAPHIC ELEMENTS Customer Approval: • For sign area allotment, each leased Tenant/Occupant space is allowed (1.5) sq. ft. of sign area per each lineal ft. of ground level Tenant/Occupant building frontage. Each sign element (logo/letter) to Tenant/Occupant sign letter/logo sizing and design are subject to review U.L.Listed be enclosed within rectangular graphic area boxes with no more than Signs to be manufactured to U.L.Specifications and will g g p and approval by Landlord/City prior to manufacturing or installation.Actual bear the U.L.Label(s).The sign is intended to be installed (12) sides.The area of this shape is the calculation for signage. in accordance with the requirements ofArticle 600 of the Tenant/Occupant layout will further be dictated by square footage allotment National Electrical Code and/or other applicable local codes. Please refer to MSP for Tenant sign specifications per Tenant This includes proper grounding and bonding of the sign. and building fascia configuration as well as Tenant/Occupant's specific logo facade type. Electrical Circuits standards. Customer to provide primary dedicated electrical circuit(s) with a separate ground to the electrical panel.L.E.D. Electronics to have a separate dedicated 120V complete • All sign letters/logos to be face or halo illuminated. Secondary copy circuit(No shared neutral).Common ground to electrical may be non-illuminated, but must be dimensional with min. 1 " depth panel acceptable. and mounted to offset outline F.C.O. backer r�anels.All racewa s are to copy 016 N Y All print and electronic art remains the sole,copyrighted ot to be be hidden/obsured behind F.C.O. offset outline backer panel(s). propbuted,cperty of ied,eeoncompanyandarenanyway distributed,copied,e-mailed or transferred in any way Landlord/City reserves final design and color approval prior to without prior written release from Pacific Neon Company. manufacturing. California Title 24 Compliant • Community Development Department Planning Division — Cupertino 'CUPLRTIN4 APPROVED ESTABLISHED _ 46 Case # S-2020-001 FPACIFIC Application Number(s) NEON Approval Body: Director/Staff Approval Date 12/11/20 2939 Academy Way Signature Gian Paolo Martire Sacramento,California 95815 Case Manager Tel 916.927.0527 Fax 916.927.2414 www.pacificneon.com Project No: Account Executive: Project: Address: Drawn By: Date: Revision: Customer Approval: U.L.Listed Signs to be manufactured to U.L.Specifications and will bear the U.L.Label(s).The sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. Electrical circuits Customer to provide primary dedicated electrical circuit(s) with a separate ground to the electrical panel.L.E.D. Electronics to have a separate dedicated 120V complete circuit(No shared neutral).Common ground to electrical panel acceptable. Copyright 02016 All print and electronic art remains the sole,copyrighted property of Pacific Neon Company and are not to be distributed,copied,e-mailed or transferred in any way without prior written release from Pacific Neon Company. California Title 24 Compliant 19900 Stevens Creek Shopping Center Tenant Signs - 3D Model view M Community Development Department Planning Division — Cupertino CUPERTINO APPROVED ESTABLISHED 1946 Case# S-2020-001 Application Number(s) NEON Approval Body: Director/Staff Approva I Date 12/11/20 2939 Academy Way Signature Glan Paolo Martlre Sacramento,California 95815 Case Manager Tel 916.927.0527 Fax 916.927.2414 www.pacificneon.com Project No: 19-0928-07 Assemb Account led 3p all II Executive: Sohn Richardson Siding Bac 19900 Stevens Creek kground I V1all Shopping Center Address: NOTE: 19900 Stevens Creek Boulevard NO MOUNTING HARDWARE OR ELECTRICAL SHOWN FOR SIMPLIFICATION PURPOSES Cupertino,CA 95014 Drawn By: William Dickson Date: 4.20.20 5/8"DIA.RIGID CONDUIT POWER SUPPLY Revision: BRIDGES BETWEEN RACEWAY CABINETS CORRUGATED METAL SIDING ABOVE TENANT SPACE Customer Approval: i U.L.Listed Signs to be manufactured to U.L.Specifications and will bear the U.L.Label(s).The sign is intended to be installed in accordance with the requirements of Article 600 of the �/— National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. FABRICATED ALUMINUM Electrical circuits Customer to provide primary dedicated electrical circuit(s) p 00 --- ► RACEWAY(S)ATTACHED TO FACE OF with a separate ground to the electrical panel.L.E.D. CORRUGATED METAL SIDING Electronics to have a separate dedicated 120V complete circuit(No shared neutral).Common ground to electrical panel acceptable. EC.O.ALUMINUM OFFSET OUTLINE Copyright®2o16 FACES OF BACKER PAN E All print and electronic art remains the sole,copyrighted xpl0ded p 0 RACEWAY CABINET(S) property of Pacific Neon Company and are not to be 3 distributed,copied,e-mailed or transferred in any way IIIwithout prior written release from Pacific Neon Company. UStratl°n , - 1 FABRICATED ALUMINUM PAN CHANNEL dch LETTERS/LOGO ATTACH EDTO FACE(S)OF California Title 24 Compliant Sign Element La EC.O.OFFSET OUTLINE BACKER PANEL(S) yer Disassembled 19900 Stevens Creek Shopping Center Tenant Signs - Fabricated Alumnum Pan Channel Letters & Logo Attached to Concrete Fascia M Community Development Department Planning Division — Cupertino CUPERTINO APPROVED ESTABLISHED 1946 Case# S-2020-001 NOTE: P NO ELECTRICAL BRIDGING BETWEEN RACEWAYS Application Number(s) ARE ALLOWED ON CONCRETE FACADES.EACH ■ RACEWAY TO HAVE SEPARATE ELECTRICAL Approval Body: Director/Staff FEEDS THRU CONCRETE STRUCTURE.ELECTRICAL 12/11/20 FEEDS TO BE LOCATED ABOVE ROOF LINE.ALL Approva I Date FEEDS BEHIND PARAPET WALL&INTO ROOF 2939 Academy Way Signature Gian Paolo Martire MEMBRANE TO BE WEATHER SEALED. Sacramento,California 95815 Case Manager PAN CHANNEL F.C.O.ALUMINUM Tel 916.927.0527 OFFSET OUTLINE Fax 916.927.2414 m LETTERS/LOGO BACKER PANEL www.pacificneon.com m z m Project No: 19-0928-07 m N = 6 06 Account _ _ e Executive: John Richardson 0 D 3"DEEP FABRICATED ALUM. SELF-CONTAINED RACEWAY 0 PAINTED TO MATCH Project: A CONCRETE FASCIA SURFACE 19900 Stevens Creek t Shopping Center ILLUMINATED Address: PAN CHANNEL LETTER 19900 Stevens Creek Boulevard Cupertino,CA 95014 m Illuminated Pan Channel Letters/Logo with F.C.O. Offset Outline Backer Panel - Scale 3/4" = 1'-0" Drawn By: William Dickson PRIMARY ELECTRICAL Date: 4.20.20 THRU CONCRETE WITH ALL PENETRATIONS SEALED Revision: WITH WEATHERTIGHT ri MATERIALS F.C.O.ALUMINUM OFFSET OUTLINE CONCRETE FASCIA BACKER PANEL Customer Approval: FC.O.ALUMINUM ABOVE TENANT SPACE(S) PAN CHANNEL OFFSET OUTLINE LETTERS/LOGO BACKER PANEL U.L.Listed Signs to be manufactured to U.L.Specifications and will I bear the U.L.Label(s).The sign is intended to be installed Min accordance with the requirements of Article 600 of the I a End View- scale 1 = 1 -0" National Electrical Code and/or other applicable local codes. . This includes proper grounding and bonding of the sign. Electrical Circuits Customer to provide primary dedicated electrical circuit(s) SILHOUETTE OF RACEWAY NOTE: with a separate ground to the electrical panel.L.E.D. Electronics to have a separate dedicated 120V complete BEHIND BACKER PANEL PAINTED SIGNS TO BE CONSTRUCTED&INSTALLED BY circuit(No shared neutral).Common ground to electrical TO MATCH CONCRETE FASCIA LICENCED/BONDED SIGN CONTRACTOR ONLY. panel acceptable. SILHOUETTE OF RACEWAY ALL SIGNS TO BE CERTIFIED U.L.COMPLIANT& Copyright®2o16 BEHIND BACKER PANEL PAINTED BEAR VISIBLE APPROPRIATE LABELING AS SUCH. All print and electronic art remains the sole,copyrighted property of Pacific Neon Company and are not to be TO MATCH CONCRETE FASCIA distributed,copied,e-mailed or transferred in any way without prior written release from Pacific Neon Company. California Title 24 Compliant m Illustration of Raceway Locations Behind Letters/ Logo (Ghosted for Clarity of Position) - Scale 3/4" = 1'-0" 19900 Stevens Creek Shopping Center Tenant Signs - 3D Model view M Community Development Department Planning Division — Cupertino CUPERTINO APPROVED ESTABLISHED 1946 Case# S-2020-001 Application Number(s) NEON Approval Body: Director/Staff Approva I Date 12/11/20 2939 Academy Way Signature Gian Paolo Martire Sacramento,California 95815 Case Manager Tel 916.927.0527 Fax 916.927.2414 www.pacificneon.com Project No: 19-0928-07 Assembled Account 3p Model I Executive: John Richardson Project: Illu Stratton As shown Attached to Co 19900 Stevens Creek NOTE: Concrete Background I wall Shopping Center NO MOUNTING HARDWARE OR ELECTRICAL Address: SHOWN FOR SIMPLIFICATION PURPOSES 19900 Stevens Creek Boulevard Cupertino,CA 95014 Drawn By: William Dickson ' Date: 4.20.20 Revision: CONCRETE FASCIA — — —JI ABOVE TENANT SPACE Customer Approval: U.L.Listed Signs to be manufactured to U.L.Specifications and will bear the U.L.Label(s).The sign is intended to be installed - in accordance with the requirements of Article 600 of the FABRICATED ALUMINUM National Electrical Code and/or other applicable local codes. i------- � This includes proper grounding and bonding of the sign. RACEWAY(S)ATTACHED TO s J CONCRETE FASCIA Electrical Circuits I _ Customer to provide primary dedicated electrical circuit(s) 111 ii �' '� � with a separate ground to the electrical panel.L.E.D. i Electronics to have a separate dedicated 120V complete circuit(No shared neutral).Common ground to electrical -- 6 - panel acceptable. — _ F.C.O.ALUMINUM OFFSET OUTLINE Copyright 02016 BACKER PANEL ATTACHED TO FACE(S)OF All print and electronic art remains the sole,copyrighted Exploded M RACEWAY CABINET(S) property of Pacific Neon Company and are not to be model III �' distributed,copied,e-mailed or transferred in any way ------/ � without prior written release from Pacific Neon Company. r — 'FABRICATED ALUMINUM PAN CHANNEL statj on Each LETTERS/LOGO ATTACHED TO FACE(S)OF California Title 24 Compliant Sign Element Layer Disassembled F.C.O.OFFSET OUTLINE BACKER PANEL(S) 19900 Stevens Creek Shopping Center D/F Monument Sign Community Development Department Planning Division — Cupertino CUPERTIN4 APPROVED ESTABLISHED 1946 Case # S-2020-001 Application Number(s) ■ Approval Body: Director/Staff A rova I Date 12/11/20 MODULAR DESIGN DIMENSIONAL pp 2939 Academy Way = 10'-0.. V-2" DIVIDERS FOR OPTIONAL FUTURE Sacramento,California 95815 Signature Gian Paolo Martire RECONFIGURATION(IF NECESSARY) Case Manager Tel 916.927.0527 11 1— TT Fax 916.927.2414 rp www.pacificneon.com TENANTAT 3 Ai TENANT W Project No: 19-0928-07 T7ENANT 1 '= Account TENANT 31 Executive: John Richardson IA TENANTI Project: io l 19900 Stevens Creek TENANT 5qE Me `�4�; Shopping Center TE NA N T 2 -E NA N T Address: 19900 Stevens Creek Boulevard TENANT • TENANT • Cupertino,CA 95014 O2 3 Drawn By: William Dickson L M, Date: 4.20.20 Revision: g 23.20 r � 10'-4" _I Customer Approval: D/F Illuminated Monument Sign (Side 1) End View(Facing Parking Lot) D/F Illuminated Monument Sign(Side 2) Scale 112" =V-0" Scale 112"=V-0" Scale 112 =V-0" Sign Area:47.5 sq.ft. U.L.Listed Signs to be manufactured to U.L.Specifications and will bear the U.L.Label(s).The sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. Electrical Circuits Material Schedule Customer to provide primary dedicated electrical circuit(s) with a separate ground to the electrical panel.L.E.D. O NOTE: Electronics to have a separate dedicated 120V complete Tenant Panels/Cabinet O Base circuit(No shared neutral).Common ground to electrical Cabinet to be fabricated aluminum construction.Tenant panels to be Fabricated aluminum frame construction skinned with AEP Span Flex MONUMENT SIGN TO BE INSTALLED UTILIZING panel acceptable. aluminum with routed,1/2" push-thru White acrylic graphics.Face and Series 1.2FX10-20 metal siding with Slate Gray Standard Finish EXISTING FOOTING AND PIPE STRUCTURE(ALL returns of tenant panels to have light(sand)texcote finish painted (prepainted). SIZES&CONDITIONS TO BE VERIFIED) Copyright®2016 Medium Gray(T.B.D.).Cabinet to be internally illuminated with White All print and electronic art remains the sole,copyrighted property of Pacific Neon Company and are not to be LED module grid. O4 Fabricated aluminum 11/2"s .Grid Dividers tube plant-on dimensional dividers to be distributed,copied,e-mailed or transferred in any way q P without prior written release from Pacific Neon Company. O Reveal painted to match Matthews Brush Aluminum,satin finish.Note:Grid All cornice and dividers to be fabricated aluminum with exposed dividers to butt against horizontal divider(modular construction)to California Title 24 Compliant surfaces painted to match AEP Span Slate Gray,matte finish. allow option of removal for future tenant reconfigurations if necessary (see drawing for butt joint placements). 19900 Stevens Creek Shopping Center D/F Projecting Pedestrian Corridor Tenant Signs (Interior) 0 Community Development Department Planning Division — Cupertino CUPERTINO APPROVED ESTABLISHED 1946 Case# S-2020-001 Application Number(s) NEON Approval Body: Director/StafF Approva l Date 12/11/20 ��2.52 �� 1'-2" 2939 Academy Way Signature Gian Paolo Martire Sacramento,California 95815 Case Ma t�a�e Tel 916.927.0527 Fax 916.927.2414 www.pacificneon.com 00 I Project No: 19-0928-07 = N N I N Account Executive: John Richardson oo ant Sign Project: 19900 Stevens Creek ® 1 77 Shopping Center Address: 19900 Stevens Creek Boulevard Section View End View of Plaque Cap and Bracket Projecting Sign Plaque Cupertino,CA 95014 Scale 1-112" =V-0" Scale 1-1/2" =V-0" Drawn By: William Dickson Date: 4.20.20 Revision: -- V 61 Material Schedule Customer Approval: 1O Projecting Sign System Vista Sign System extrusion V11x350-WBS27 w/ clear aluminum finish. U.L.Listed OHeader/Tenant Panel Strips Signs to be manufactured to U.L.Specifications and will PVC Black w/matte finish.All copy to be bear the U.L.Label(s).The sign is intended to be installed applied 3 M White Vinyl. in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. Electrical Circuits - Customer to provide primary dedicated electrical circuit(s) Interior Wall Section with a separate ground to the electrical panel.L.E.D. Electronics to have a separate dedicated 120V complete Scale 1/2 =1 -0 circuit(No shared neutral).Common ground to electrical panel acceptable. Pedestrian Sign Copyright02016 of Projecting All print and electronic art remains the sole,copyrighted el View property of Pacific Neon Company and are not to be 3D Mod distributed,copied,e-mailed or transferred in any way without prior written release from Pacific Neon Company. California Title 24 Compliant 19900 Stevens Creek Shopping Center I Typical Tenant/Occupant Door & Window Graphics Community Development Department Planning Division — Cupertino CUPERTIN4 APPROVED ESTABLISHED 1946 Case # S-2020-001 Application Numbers) No additional window signs beyond NEON address/suite number is allowed Approval Body: Director/Staff Approval Date 12/11/20 NO WINDOW GRAPHICS 3M 3630-20 White vinyl NO WINDOW GRAPHICS 2939 Academy Way Signature Gian Paolo Martire SIGN ALLOWED film applied 1st Surface. SIGN ALLOWED Sacramento,California 95815 II Case Manager i Tel 916.927.0527 927.2414 42O N Fax 916.www.pacificncificneon.com Project No: 19-0928-07 420 IF NO TRANSOM Account Executive: John Richardson Tenant Name Tenant Name 1 ------ --------- Project: Hours of Operation 19900 Stevens Creek Additional Window Additional Window Graphics Area Graphics Area (Not to Exceed 20% (Not to Exceed 20% (Not to Exceed 20% (Not to Exceed 20% Shopping Center of Total Window Area) ;of Total Window Area); :of TotaI Window Area)', of Total Window Area) Address: ------------------------ --------------- --------------- ------------------------------- 19900 Stevens Creek Boulevard Cupertino,CA 95014 Drawn By: William Dickson Date: 4.20.20 Revision: g 23.20 Customer Approval: Window Graphics Scale 1/2"=V-0" U.L.Listed Signs to be manufactured to U.L.Specifications and will bear the U.L.Label(s).The sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. Electrical Circuits TENANT DOOR&WINDOW GRAPHICS 5. Graphics/copy on doors,address numerals and hours of operation shall be white vinyl 11. All window graphics are subject to review and approval at Landlord's discretion. Customer to provide primary dedicated electrical circuit(s) film. Violation of guidelines will require removal of window graphics at tenant's own with a separate ground to the electrical panel.L.E.D. q g p Electronic to have a separate dedicated 120V complete 1. Window signs are limited to tenant name,logo,hours of operation or graphics related expense. circuit(No shared neutral).Common ground to electrical to business identity. 6. No limitation on design or color for secondary graphics located on sidelight window(s) panel acceptable. provided that window graphics relate to tenant business or services. 12. Upon termination of lease,all window signs must be removed at tenant's expense. ° Glazing must be returned to original condition.If glazing cannot be to returned to Copyright®2016 2. Window signage must not exceed 20/o of the glazed area of the individual window 99 g All print and electronic art remains the sole,copyrighted panes. 7. Paper,hand painted holiday signs or temporary signs are strictly prohibited. original condition,tenant is required to provide replacement at tenant's own expense. property of Pacific Neon Company and are not to be distributed,copied,e-mailed or transferred in any way 3. All tenants are required to have address numerals applied either over 8. No graphics of any kind are allowed on the upper windows and door transom(except without prior written release from Pacific Neon Company. entrance doors as shown or on right(entrance door)if tenant has no transom.Address address numerals). California Title 24 Compliant numerals shall be 6"copy if located on transom and 3"if located on right door glazing. 9. Graphics that are perceived as abusive,inflamatory or obscene by community standards are strictly prohibited and are subject to immediate removal at tenant's expense. 4. All tenants are required to have hours of operation as part of their window graphics package and should be located either on entrance door or adjacent sidelight window. 10. No block-out film to obscure or hide occupying tenant space will be allowed. Hours should be displayed at an appropriate height and visibility. 19900 Stevens Creek Shopping Center Building Elevations & Typical sign Placement Community Development Department NOTE: D7 Planning Division — Cupertino ALL SIGN PLACEMENTS SHOWN ARE FOR DEMONSTRATION PURPOSES ONLY.FINAL SIZES,QUANTITIES AND LOCATION T.B.D. �CUPERTIN4 APPROVED = - 1946 Case # S-2020-001 Application Numbers) ■ Approval Body: Director/Staff 1 Approval Date 12/11/20 2939 Academy Way • • TENANT Signature Gian Paolo Martire Sacramento,California 95815 r � Case Manager Tel 916.927.0527 Fax 916.927.2414 www.pacificneon.com North Elevation -Scale 1"=20'-0" Project No: 19-0928-07 Account DASHED RED LINE Executive: John Richardson INDICATES ROOF LINE Project: 19900 Stevens Creek Shopping Center — I I --- __-- 40 __-- --- -- -- ---- --®Ter�cw -- --TENANT --mom -- Address: P19900 Stevens Creek Boulevard Cupertino,CA 95014 i0f, IN�11111Drawn By: William Dickson East Elevation-scale 1"=zo'-o" Date: 4.20.20 Revision: DASHED RED LINE INDICATES ROOF LINE SIGN PLACEMENT NOTE: Customer Approval: — SIGNS MOUNTED ON CONCRETE FASCIAS _______ 71•IIAIIrC______________t A MUST HAVE ELECTRICAL PENETRATIONS T11 ABOVE ROOF LINE&BE OBSCURED .04, IN FROM VIEW. U.L.Listed Signs to be manufactured to U.L.Specifications and will bear the U.L.Label(s).The sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. South Elevation-Scale 1"=20'-0" Electrical Circuits Customer to provide primary dedicated electrical circuit(s) DASHED RED LINE with a separate ground to the electrical panel.L.E.D. Electronics to have a separate dedicated 120V complete INDICATES ROOF LINE circuit(No shared neutral).Common ground to electrical panel acceptable. Copyright 02016 All print and electronic art remains the sole,copyrighted _ property of Pacific Neon Company and are not to be distributed,copied,e-mailed or transferred in any way without prior written release from Pacific Neon Company. TENANT------------- ------- ----------- -- -------- ----------- --------------- ------------- California Title 24 Compliant West Elevation-Scale 1"=20A , 19900 Stevens Creek Shopping Center Site Plan & Sign Locations Community Development Department Planning Division — C u p e ling EXISTING BUILDINGS ON ADJACENT PROPERTY 'CUPLRTIN4 AP ROVED � = - - 35-0" Case # 6So.20210 1 pplicatio Num er(s) 0°13'00"E Approval o y hector Staff E LANDSCAPE ------------------ - (E)LANDSCAPE ----------------------- i I Approval a e 12/11/ 0 1 2 3 4 1ffi 14 1a 1s 17 18 19 22 23 24 26 26 27 28 I 2939 Academy Way Signature la Paolo artlr Sacramento,California 95815 m ® \ ❑� I Tel916.927.0527 Case ana er — a Fax 916.927.2414 www.pacificneon.com TRUCK RADIUS — �� �� Aso Project No: 19-0928-07 8 0 RI NGLE `� `� Account Executive: 72 32 John Richardson 196 105 i 104 11033 1002 lot 'Go 99 96 97 96 95 94 93 92 91 9® 69 ffi6 87 as � I � I � Project: 76 71 II II I 66 �r 19900 Stevens Creek 10 — 1 11 . — E PLANTER 74 70 ffi4 Q Shopping Center �o II m va m 76 69 ffi� I Address: a 76 so as i w 19900 Stevens Creek Boulevard W m W Cupertino,CA 95014 a l o Q Q 77 67 37 Drawn By: William Dickson 0 o I O W U4t - - - - - -T- - - - - - - - - - - — 7ffi 66 38 ° Date: 4.20.20 162 103 104 105 106 IN O Revision: 2 -- -- -- -- - - -__ -- -- - -- -- -- -- -- -- - -- -- - - -- -- -- 9.23.20 10.8.20 O --- ( - -- - o -- - - - - -- -- - o m ° ffi9 Ycli3 w w 107 g ffi® 64 Q It LU 0 115 ffi1 66 o Q U 41 ,o �, zo o W z 6) � � 82 62 I9 � Customer Approval: ao 00 "' Z D oPoseaE.,,Co, o. 42 U, w (E) CONCRFJT W LK .m ffiffi 61 I (n I— - 'I w � 4ffi 84 69 U.L.Listed Signs to be manufactured to U.L.Specifications and will 4me _ I I I I I 44 bear the U.L.Label(s).The sign is intended to be installed 114 I I 85i rig / 1 ) in accordance with the requirements of Article 600 of the / / / 4� National Electrical Code and/or other applicable local codes. 7 - / This includes proper grounding and bonding of the sign. Electrical Circuits Customer to provide primary dedicated electrical circuit(s) Q with a separate ground to the electrical panel.L.E.D. i - -- 112 111 110 109 108 c ——--— 47 Electronics to have a separate dedicated 120V complete circuit(No shared neutral).Common ground to electrical panel acceptable. w 113 0 48 1 -------——-- _ Copyright 02016 w I All print and electronic art remains the sole,copyrighted Q affi property of Pacific Neon Company and are not to be a I distributed,copied,e-mailed or transferred in any way ?, 67 66 66 ri4 6,ffi 6� 6i1 66 49 without prior written release from Pacific Neon Company. California Title 24 Compliant N 0°13'00"W 372.28' -------------------------- I11JLheet No. Scale 1 —30'-0 EXISTING PARKING LOT ON ADJACENT PROPERTY 15 19900 Stevens Creek Shopping Center I Sign Allowance Matrix C rrlrrrra writ-D1�ve I�purl e lDp�rhr�n e r1t 19900 STEVENS CREEK LLC GENERAL NOTES Planning Divisic)n SE P ;l �,10N PRIMARY WALL SIGNAGE 1.)WALL SIGNAGE: C V PERTIIYO APPROVED ALLOWABLE SIGNAGE AREA: LIGHT 1 WALL SIGN PER BUSINESS WITH EXTERIOR FRONTAGE ESTABLISHED 1946 I WALL SIGNAGE AREA 1 LF.= MAX.LENGTH AT 70% SOURCE. PERMANENT WINDOW 1 SF OF WALL SINGE PER 1.5 LF OF STORE FRONTAGE WHICH THE SIGN IS LOCATED PRIMARY LEASED Case # S-2020-00 I 1.5 SQ.FT.(MAX 200 SF).SEE OF FRONTAGE (FT.) SEE NOTE SIGNAGE.5 SF/1.LINEAR LENGTH NOT TO EXCEED 70%OF MAX.FRONTAGE ANT NAME FRONTAGE(FT). NOTE(A) WALL SIGN ID# SEE NOTE E&F (B) FT SEE NOTE(D) PACIFIC 1 R '�Mt s 4LA M A vard 101 Not Occupied 40'-3" 40 28 ■ p-1 1 19900 Stevens Creek Boulevard 102 Not Occupied 23'-6" 24 16 Approva D60V. XmQ ulevard 103 Not Occupied 33'-6" 34 23 2.)GROUND SIGNAGE: 1 1 t reek Boulevard 104 Not Occupied 24'-7" 25 17 Approva -D�# ,Occupied 23'-6" 24 17 2939 Academy Way uIeva'`" 1Vrd 106 , 1 SF OF FREESTANDING SIGN FOR EVERY FOUR FEET OF STREET FRONTAGE.ACTUAL FRONTAGE 224.96. Sacramento,California 95815 Signatur 1 Boouleva Not Occupied 23'-3" 23 16 ACTUAL FRONTAGE 224.96.MAXIMUM SQUARE FOOTAGE OF ADVERTISEMENT=54 SF. 1 19900 tev��er�s areeRk Boulevard 107 Not Occupied 21'-8" 22 15 MAXIMUM SIGN HEIGHT=8' Tel 916.927.0527 1 19900 Stevens Creek Boulevard 108 Not Occupied 23-3" 23 16 MAXIMUM NUMBER OF TENANT PANELS=6 Fax 916.927.2414 1 19900 Stevens Creek Boulevard 109 Not Occupied 23'- 6" N/A N/A www.pacificneon.com STREET ADDRESS SHALL BE CLEARLY IDENTIFIED IN NUMERALS NO LESS THAN 5"IN HEIGHT 1 19900 Stevens Creek Boulevard 110 Not Occupied 25'-4" N/A N/A 1 19900 Stevens Creek Boulevard 111 Not Occupied 21'-8" N/A N/A NOTE(S): Project NO: 1 9-0928-07 1 19900 Stevens Creek Boulevard 112 Not Occupied 23'-6" N/A N/A 1 19900 Stevens Creek Boulevard 113 Not Occupied 34'-1" 24 17 Ac count A.)FRONTAGE ROUNDED TO THE NEAREST FOOT.ALLOWABLE Executive: John Richardson 1 19900 Stevens Creek Boulevard 114 Not Occupied 28'-9" 20 SIGN AREA NOT TO EXCEED THE STATED ALLOWANCES. 1 19900 Stevens Creek Boulevard 115 Not Occupied 36'-4" 36 25 B.)INTERNALLY ILLUMINATED Project: 19900 Stevens Creek 1 106 05 104 103 102 101 1®® 00 03 08 06 00 94 00 02 01 00 go i BP 87 90 Shopping Center — Address: I E PLANTER - 19900 Stevens Creek Boulevard I ae ieona --- -- _ Cupertino,CA 95014 m m Drawn By: m � William Dickson Date: 4.20.20 Revision: 6.25.20 101 9.23.20 10.8.20 102 103 104 105 106 I Y I � 3 107 Customer Approval: 115 I 0. ':0 I P, —EA conm. U.L.Listed :REr, w LK _ Signs to be manufactured to U.L.Specifications and will bear the U.L.Label(s).The sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. ° This includes proper grounding and bonding of the sign. Z 114 Electrical Circuits Customer to provide primary dedicated electrical circuit(s) _ _ T with a separate round to the electrical panel.L.E.D. --- - - - - - - _ P 9 � — — ti t � a i Electronics to have a separate dedicated 120V complete �_1_�y '�_1_w __�_ circuit(No shared neutral).Common ground to electrical panel acceptable. 111 110 109 108 Copyright 02016 o° All print and electronic art remains the sole,copyrighted property of Pacific Neon Company and are not to be 113 distributed,copied,e-mailed or transferred in any way 3� without prior written release from Pacific Neon Company. w _ California Title 24 Compliant it I 1 Z „ais Aoo SY I , - N 0°13'00"W 372.28' FLOOR PLAN OF LEASING SPACES -