HomeMy WebLinkAboutAH Packet 03-11-2021CITY OF CUPERTINO
ADMINISTRATIVE HEARING
AGENDA
This will be a teleconference meeting with no physical location .
Thursday, March 11, 2021
5:00 PM
Teleconference Meeting
TELECONFERENCE / PUBLIC PARTICIPATION INFORMATION TO HELP STOP THE
SPREAD OF COVID-19
In accordance with Governor Newsom’s Executive Order No-29-20, this will be a
teleconference meeting without a physical location to help stop the spread of COVID-19.
Members of the public wishing comment on an item on the agenda may do so in the
following ways:
1) E-mail comments by 4:00 p.m. on Thursday, March 11th to the Hearing Officer at
planning@cupertino.org. These e-mail comments will be received by the Hearing Officer
before the meeting and posted to the City’s website after the meeting.
2) E-mail comments during the times for public comment during the meeting to the
Hearing Officer at planning@cupertino.org. The staff liaison will read the emails into the
record, and display any attachments on the screen, for up to 3 minutes (subject to the
Hearing Officer’s discretion to shorten time for public comments). Members of the public
that wish to share a document must email planning@cupertino.org prior to speaking.
3) Teleconferencing Instructions
Members of the public may observe the teleconference meeting or provide oral public
comments as follows:
Oral public comments will be accepted during the teleconference meeting . Comments may
be made during “oral communications” for matters not on the agenda, and during the
public comment period for each agenda item .
To address the Commission, click on the link below to register in advance and access the
meeting:
Online
Page 1
Administrative Hearing Agenda March 11, 2021
Please click the link below to join the webinar :
https://cityofcupertino.zoom.us/webinar/register/WN_KtpymyIwQHKilUTP40fEkw
Phone
Dial 669-900-6833 and enter Webinar ID: 921 8874 7243 (Type * 9 to raise hand to speak)
Unregistered participants will be called on by the last four digits of their phone number .
Or an H.323/SIP room system:
H.323:
162.255.37.11 (US West)
162.255.36.11 (US East)
Meeting ID: 921 8874 7243
SIP: 92188747243@zoomcrc.com
After registering, you will receive a confirmation email containing information about
joining the webinar.
Please read the following instructions carefully:
1. You can directly download the teleconference software or connect to the meeting in your
internet browser. If you are using your browser, make sure you are using a current and
up-to-date browser: Chrome 30+, Firefox 27+, Microsoft Edge 12+, Safari 7+. Certain
functionality may be disabled in older browsers, including Internet Explorer .
2. You will be asked to enter an email address and a name, followed by an email with
instructions on how to connect to the meeting . Your email address will not be disclosed to
the public. If you wish to make an oral public comment but do not wish to provide your
name, you may enter “Cupertino Resident” or similar designation.
3. When the Hearing Officer calls for the item on which you wish to speak, click on “raise
hand.” Speakers will be notified shortly before they are called to speak.
4. When called, please limit your remarks to the time allotted and the specific agenda topic .
In compliance with the Americans with Disabilities Act (ADA), anyone who is planning to
attend this teleconference meeting who is visually or hearing impaired or has any disability
that needs special assistance should call the City Clerk's Office at 408-777-3223, at least 48
hours in advance of the meeting to arrange for assistance. In addition, upon request, in
advance, by a person with a disability, meeting agendas and writings distributed for the
meeting that are public records will be made available in the appropriate alternative
format.
Page 2
Administrative Hearing Agenda March 11, 2021
ROLL CALL
APPROVAL OF MINUTES
1.Subject: Draft Minutes of February 11, 2021
Recommended Action: Approve or modify the Draft Minutes of February 11, 2021
Draft Minutes of February 11, 2021
ORAL COMMUNICATIONS
This portion of the meeting is reserved for persons wishing to address the Committee on any matter
within the jurisdiction of the Committee and not on the agenda. Speakers are limited to three (3)
minutes. In most cases, State law will prohibit the Commission from making any decisions with respect
to a matter not on the agenda.
WRITTEN COMMUNICATIONS
PUBLIC MEETING
2.Subject: Architectural and Site Permit to consider exterior and landscape alterations to
the Arioso Apartments existing pool deck area; and a Tree Removal Permit to allow the
removal and replacement of four (4) protected development trees at an existing
apartment complex (Arioso). Application No(s).: ASA-2020-006, TR-2020-044;
Applicant(s): Tim Barnes (Studio G Architects, Inc.); Location: 19608 Pruneridge Ave
APN #316-45-016
Recommended Action: That the Hearing Officer adopt the draft resolutions to:
1) Find that the proposed projects are exempt from CEQA; and
2) Approve the Architectural and Site Approval Permit (ASA-2020-006) and the Tree
Removal Permit (TR-2020-044).
Hearing Officer decision final unless appealed
Staff Report
1 - Draft Resolution for ASA-2020-006
2 - Draft Resolution for TR-2020-044
3 - Plan Set
4 - Arborists Report
OLD BUSINESS
NEW BUSINESS
ADJOURNMENT
In compliance with the Americans with Disabilities Act (ADA), anyone who is planning to attend this
teleconference meeting who is visually or hearing impaired or has any disability that needs special
assistance should call the City Clerk's Office at 408-777-3223, at least 48 hours in advance of the
Page 3
Administrative Hearing Agenda March 11, 2021
meeting to arrange for assistance. In addition, upon request, in advance, by a person with a disability,
meeting agendas and writings distributed for the meeting that are public records will be made available
in the appropriate alternative format.
Any writings or documents provided to a majority of the members after publication of the agenda will
be made available for public inspection. Please contact the City Clerk’s Office in City Hall located at
10300 Torre Avenue during normal business hours.
IMPORTANT NOTICE: Please be advised that pursuant to Cupertino Municipal Code 2.08.100
written communications sent to the Cupertino City Council, Commissioners or City staff concerning a
matter on the agenda are included as supplemental material to the agendized item. These written
communications are accessible to the public through the City’s website and kept in packet archives. You
are hereby admonished not to include any personal or private information in written communications to
the City that you do not wish to make public; doing so shall constitute a waiver of any privacy rights
you may have on the information provided to the City .
Members of the public are entitled to address the members concerning any item that is described in the
notice or agenda for this meeting, before or during consideration of that item. If you wish to address the
members on any other item not on the agenda, you may do so during the public comment .
Page 4
Cupertino, CA 95014
(408) 777-3308
ACTION MINUTES OF THE REGULAR MEETING OF
THE ADMINISTRATIVE HEARING HELD ON February 11, 2021
ROLL CALL
Hearing Officer present: Albert Salvador, Assistant Director of Community Development
Staff present: Jeff Tsumura, Associate Planner
Piu Ghosh, Planning Manager
Applicant(s) present: Ray Chen, Architect
Mr. Mike Qi, Property Owner
APPROVAL OF MINUTES:
1. August 13, 2020
The minutes of August 13, 2020 were approved as written
POSTPONEMENTS/REMOVAL FROM CALENDAR:
None
ORAL COMMUNICATIONS:
None
WRITTEN COMMUNICATIONS:
Two emails were received regarding item #2
PUBLIC MEETING ITEMS:
2. Application No.(s): EA-2018-02, TM-2018-01
Applicant: Ray Chen (Lands of Qi)
Location: 11226 Bubb Rd APN #362-06-036
Tentative Parcel Map application to allow the subdivision of an existing 32,316 square feet
(0.74 acre) residential lot into three residential lots ranging betwe en 9,699 square feet and
11,928 square feet
Administrative Hearing Officer’s decision final unless appealed.
Staff member Tsumura addressed the Hearing Officer. The application for approval is a
subdivision of a .74 acre parcel into 3 residential lots. Future development will involve the
demolition of the existing single family home and the construction of 3 new single family
2 Administrative Hearing
February 11, 2021
homes on the newly created lots. The future residential development will be processed
according to the City’s Ordinances. Under consideration by the Hearing Officer at this meeting
is just the Subdivision and the Mitigated Negative Declaration applications. Staff Member
Tsumura reviewed the lot configuration and sizes. The Mitigated Negative Declaration was
deemed appropriate for the scope of this project by the Environmental Review Committee on
January 21, 2021. The Initial Study found no potential environmental impacts that could not be
mitigated to “less than significant”.
The Hearing Officer asked if the applicant would like to make a statement. The applicant
declined, but said they were available if the Hearing officer had any questions.
The Hearing Officer opened the public comment period.
Mary Lemons
Kevin Qi
The Hearing Officer closed the comment period.
The Hearing Officer asked Staff for responses to the Speaker concerns. Staff member Tsumura
reiterated that the City’s development standards would be required for the design and
architecture of the proposed new homes. They reviewed for the speaker where the driveway
accesses for each lot would probably be located as part of the residential development. Staff
member Tsumura mentioned that there are protected trees on the lot. The removal of these
trees is not part of this approval. He asked that the Hearing Officer amend the approval to
include that no protected trees will be removed.
The Hearing Officer concurred with Staff’s findings; the project is in compliance with the
Municipal Codes.
DECISION: The application was approved by the Hearing Officer per the draft resolution(s)
adding a condition stating that no trees may be removed as part of this project.
ADJOURNMENT
Respectfully submitted:
_____/s/Beth Ebben
Beth Ebben
Deputy Board Clerk
ADMINISTRATIVE HEARING STAFF REPORT
Meeting Date: March 11, 2021
Subject
Architectural and Site Approval Permit to consider exterior and landscape alterations to
the Arioso Apartments existing pool deck area and a Tree Removal Permit to allow the
removal and replacement of four protected development trees. (Application No(s).: ASA-
2020-006, TR-2020-044; Applicant: Tim Barnes; Location: 19608 Pruneridge Avenue;
APN(s): 316-45-016)
Recommended Action
That the Hearing Officer adopt the draft resolutions (Attachments 1 and 2) to:
1. Find that the proposed actions are exempt from CEQA; and
2. Approve the Architectural and Site Approval Permit (ASA-2020-006) and the Tree
Removal Permit (TR-2020-044).
Discussion
Project Data
General Plan Designation Commercial/Residential
General Plan Special Area North Vallco Special Area
Zoning Designation P(CG,Res)
Lot Size (entire project) 305,355 sq. ft. (7.01 acres)
Existing Proposed
Floor Area (entire project) 230,501 sq. ft. (75%) No Change
Lot Coverage (entire project) 76,338 sq. ft. (25%) No Change
Project Consistency With:
General Plan Yes
Zoning Yes
Environmental Assessment Categorically Exempt per Section 15301 (Class 1) of
the California Environmental Quality Act (CEQA)
ASA-2020-006, TR-2020-044 19608 Pruneridge Ave. March 11, 2021
Page 2
Background
The Arioso property is located within the
North Vallco Gateway in the North Vallco
Special Area, which is a major employment
center for Cupertino and primarily comprised
of commercial and office uses with multi-
family residential developments on both sides
of the intersection of N. Wolfe Road and
Pruneridge Avenue.
The proposed project is limited to renovations
within the existing common amenity area of
the Arioso Apartments. The common amenity
area is located on the south west corner of the
Arioso Apartment site and is bounded by
Arioso Apartment residential buildings to
the north, the Courtyard by Marriott hotel to
the east, a single-family residential planned
development to the south, and Linnet Lane the
west (see Figure 1).
The 201-unit Arioso Apartment project was
approved in 1997 (U-1996-15) and constructed
in 1999. The existing exterior materials for the
complex and associated amenity area consist of
stucco walls in a neutral color palette. The
existing pool area features a club house with
attached trellis, a concrete lower deck
surrounding a pool and hot tub, and an upper
level with a BBQ area, small fire pit, and stone
flooring (see Figures 2 & 3). The original project
approval does not include conditions of
approval related to exterior paint color or
materials.
The property owner is proposing to modernize
this space by improving functionality and
developing attractive gathering spaces for the
users.
Figure 1. Project site N. WOLFE ROAD LINNET LANE HILTON
GARDEN
INN
ARIOSO
APARTMENTS
COURTYARD BY
MARRIOT
POOL DECK
Figures 2 (above) and 3 (below)
Existing conditions.
ASA-2020-006, TR-2020-044 19608 Pruneridge Ave. March 11, 2021
Page 3
Analysis
The applicant is requesting exterior and landscape modifications to the existing pool deck
area of the Arioso Apartment complex. The scope of work for the project is as follows:
Demolition of existing trellis (attached to club house), lower deck concrete
flooring, upper deck stone flooring, BBQs, and fire pit area;
Installation of two new trellises, new built-in wood seating areas, new BBQ and
fire pit areas, new lighting fixtures, and associated hardscaping in wood and
concrete;
Replacement of the existing wrought iron fencing around the pool area with
wooden fencing;
Removal and replacement of four protected development trees; and
Installation of enhanced landscaping.
The scope of work does not include any changes to existing uses, parking supply or
demand, floor area, lot coverage, club house building height, or club house building color
for the subject site and will not result in an increased intensity of the existing use.
Therefore, only an Architectural and Site Approval permit is required for the proposed
improvements.
Exterior Modifications
The applicant is requesting to
modernize and maximize usability of
the apartment’s existing pool area by
creating small private gathering spaces
and incorporating additional textures
and finishes, including drought-
tolerant landscaping, 100% recycled
wood decking, low-maintenance
weathered steel trellises, and
contemporary wood seating and
lounging options (see Figures 4 & 5).
As part of this project, the existing
trellis attached to the club house will be
replaced with a more modern and
functional design featuring two
weathered steel (cor-ten) trellises. The
existing BBQ and fire pit areas will also
be replaced with more usable and Figure 4 (above) and 5 (below) Proposed design.
ASA-2020-006, TR-2020-044 19608 Pruneridge Ave. March 11, 2021
Page 4
intimate spaces with well-defined boundaries that have a contemporary aesthetic. The
existing club house (architectural details or colors), pool, and hot tub will not be modified
as part of the scope of work.
The proposed design includes two main amenity areas, the lower deck and an upper
terrace.
Lower deck: A 1,138 sq. ft., 12’ tall cor-ten trellis is proposed for the lower deck and will
extend over the hot tub, providing shade for the adjacent pool area (Sheets AS.4 & L5.2).
The lower deck trellis will be setback approximately 24’ from the western property line
on Linnet Lane and 14’-7” from the northern property line, which abuts the parking lot
for the Arioso Apartments. The lower trellis will, therefore, not create adverse impacts to
the surrounding area.
The lower deck will feature 100% recycled wood decking under the trellis to compliment
the warmth of the new design (Sheets L1.2 & L5.2). The remainder of the lower deck will
incorporate new concrete with moveable loung e chairs and other seating options
surrounding the hot tub and pool area (Sheet L1.3).
Upper terrace: A small 211 sq. ft. 12’ tall cor-ten trellis is proposed over the new BBQ and
seating area in the south west corner of the upper terrace space (Sheets L1.2 & L5.2). While
the subject property is located in a planned development zoning district, which allow s
for setback flexibility, staff has worked with the applicant to ensure that the trellis in this
area is setback 10’-6” from the southern property line to match the setback to height ratios
allowed under the City’s Accessory Structure Ordinance (Chapter 19.100) for accessory
structures on residential properties. This will allow sufficient distance and minimize any
potential impact to the closest single-family residence in the residential planned
development on Mine Court which abuts this area. The trellis will be setback
approximately 13’-6” from the western property line along Linnet Lane (where there are
no adjacent neighbors.)
The upper terrace will feature concrete paving with wood loungers and fire pit areas to
form separate usable areas to create a sense of privacy and natural social distancing (Sheet
L1.3). The lower deck and upper terrace will be separated by two new concrete planter
walls with drought-tolerant plantings to provide a distinct separation between the two
amenity areas.
Fencing and Lighting: The applicant is also proposing new fencing and lighting fixtures as
part of the scope of work. The existing wrought iron metal fencing and pedestrian gates,
separating the amenity space from the parking lot to the north and from Linnet Lane to
the west, will be replaced with horizontal wood fencing to compliment the new design
ASA-2020-006, TR-2020-044 19608 Pruneridge Ave. March 11, 2021
Page 5
elements (shown in Figure 5 in the background). The existing fence height is eight feet along
Linnet Lane and varies from eight feet to nine feet along the northerly fence adjacent to
the Arioso Apartment parking lot. The new fencing will be maintained at the existing
height, with no changes to proposed fence heights. The southerly fence separating the
pool deck area from the adjacent single-family residential development will not be
modified.
New landscape lighting design will incorporate low voltage tree up-lighting and LED
down-lighting for the two trellises. The applicant has provided site photometrics, which
indicate that the new light fixtures will not cause light to spill -over onto adjacent
residential properties (Sheet L1.4A).
The main objectives of the proposed design are to create more variety of useable spaces
for small gathering and provide filtered shade for residents (Sheets L5.1 & L5.2). The
proposed aesthetics for the pool deck upgrades will be compatible with the recent paint
and pedestrian entrance gate upgrades to the Arioso Apartment residential towers
previously approved with permit number DIR-2019-012. The proposed exterior changes
are minor in scope and are architecturally harmonious with the other portions of the
project.
Tree Removals/Replacements & Landscape Modifications
Per the Protected Trees Ordinance (Chapter 14.18) of the Cupertino Municipal Code
(CMC), all approved development trees (i.e. trees required to be planted or retained as
part of a development application, building permit, tree removal permit, or code
enforcement action) are considered “protected” and require approval of a Tree Removal
Permit prior to removal. Replacements for the removed trees are required as part of the
Tree Removal Permit.
The applicant is proposing to remove a total of four protected development trees as part
of the proposed modifications to the pool deck area (Sheet LD.2). The arborist report
provided (Attachment 4) assesses the location, size, current condition, and overall health
of the all trees on the property. The four trees proposed for removal have been identified
to be in fair and poor condition. The table below includes the trees proposed for removal.
TABLE 1 – TREES TO BE REMOVED AND REPLACEMENTS
Tree ID # Tree Species DBH Condition Required Replacement(s)
17 Sweetgum
(Liquidambar styraciflua) 7” Fair One 24”-box
18 Red Tip Photinia
(Photinia x fraseri) 2” Poor One 24”-box
ASA-2020-006, TR-2020-044 19608 Pruneridge Ave. March 11, 2021
Page 6
TABLE 1 – TREES TO BE REMOVED AND REPLACEMENTS
Tree ID # Tree Species DBH Condition Required Replacement(s)
19 Coast Redwood
(Sequoia sempervirens) 14” Fair Two 24”-box
(or One 36”-box)
20 Brisbane Box
(Lophostemon confertus) 4” Poor One 24”-box
Total Replacements Required per Municipal Code
Five 24”-box OR
Three 24”-box and one 36”-
box
* Note: tree ID # corresponds with the tree inventory provided with the arborist report
The required replacement trees per the Protected Trees Ordinance are five 24”-box trees
or one 36”-box plus three 24”-box trees. The applicant exceeds the minimum number of
replacement trees by proposing a total of 14 36”-box trees of various species to be planted
on site and two additional 36”-box native Oak (Quercus Agrifolia) to be planted across
Linnet Lane at the playground and field owned and managed by the Arioso Apartment
complex (Sheets L4.1 & L4.2). All replacement trees will be retained on the site as
protected development trees. The arborist report and proposed tree replacement species
and locations were peer-reviewed by the City’s Arborist who had no objections to the
project.
The applicant is also proposing to modify the existing landscape by replacing portions of
the existing planting area around the perimeter of the project area with native and
drought-tolerant ground cover (Sheets L4.1 & L4.2). The project is subject to a Prescriptive
Compliance Application per the Landscape Ordinance (Chapter 14.15) of the CMC. The
Landscape Ordinance requires the applicant to submit a Water-Efficient Landscape
Checklist and finalized landscape and irrigation plans prior to building permit issuance.
The new landscape and replacement trees, discussed above, will be compatible with the
new design of the amenity area and will provide a buffer and added privacy for the
adjacent residential properties.
Environmental Review
This project is categorically exempt from the requirements of the California
Environmental Quality Act (CEQA) per Section 15301 – Existing Facilities.
Other Department/Agency Review
The City’s Building Division, Environmental Programs Division, Public Works
Department, and the Santa Clara County Fire Department have no objections to the
project.
ASA-2020-006, TR-2020-044 19608 Pruneridge Ave. March 11, 2021
Page 7
Public Noticing & Community Outreach
The following table is a brief summary of the noticing for this project:
Notice of Public Hearing Agenda
Site Signage (at least 10 days prior to
hearing)
11 notices mailed to property owners
adjacent to the project site (at least 10
days prior to the hearing)
Posted on the City's official notice
bulletin board (five days prior to
hearing)
Posted on the City of Cupertino’s
Web site (five days prior to hearing)
No comments have been received at the time of production of this staff report.
Permit Streamlining Act
This project is subject to the Permit Streamlining Act (Government Code Section 65920 –
65964). The City has complied with the deadlines found in the Permit Streamlining Act.
Project Received: November 4, 2020; Deemed Incomplete: December 4, 2020
Revisions Received: December 16, 2020; Deemed Incomplete: January 15, 2021
Revisions Received: January 20, 2021; Deemed Complete: February 18, 2021
The City has 60 days from when the project is deemed categorically exempt to decide on
the project.
Conclusion
Staff recommends approval of the Architectural and Site Approval Permit and the Tree
Removal Permit as the proposed project will not create adverse impacts to the
surrounding area. Additionally, all the findings for approval of the proposed project,
consistent with Chapter 19.168 and 14.18 of the Cupertino Municipal Code, may be made
as reflected in the draft resolutions.
With respect to the Architectural and Site Approval Permit, the following findings may
be made:
1. The proposal, at the proposed location, will not be detrimental or injurious to property
or improvements in the vicinity, and will not be det rimental to the public health,
safety, general welfare, or convenience;
The proposal includes exterior and landscape modifications to the existing pool deck area of the
Arioso Apartment complex that modernize and maximize the usability of the amenity space.
The exterior enhancements will incorporate small private gathering spaces and additional
textures and finishes, including 100% recycled wood decking, low-maintenance weathered
steel (cor-ten) trellises, contemporary wood seating and lounging options, and native
landscaping. The proposal includes minor improvements to an existing use. No changes to the
ASA-2020-006, TR-2020-044 19608 Pruneridge Ave. March 11, 2021
Page 8
location of the use is being proposed. Potential impacts to an adjacent single-family residential
property will be mitigated by setbacks, the installation of required replacement trees and
proposed landscape enhancements. Therefore, the exterior and landscape modifications will not
be detrimental or injurious to property or improvements in the vicinity, and will not be
detrimental to the public health, safety, general welfare, or convenience.
2. The proposal is consistent with the purposes of Chapter 19.168, the General Plan, any
specific plan, zoning ordinances, applicable planned development permit, conditional
use permits, variances, subdivision maps or other entitlements to use which regulate
the subject property including, but not limited to, adherence to the following specific
criteria:
a) Abrupt changes in building scale should be avoided. A gradual transition related
to height and bulk should be achieved between new and existing buildings.
The project scope does not include the modification or addition of buildings. The proposed
12-foot tall trellises are considered unenclosed accessory structures. The northerly trellis
abuts the Arioso Apartment complex parking lot. The southerly trellis will be set back 10’-
6” from the closest adjacent single-family residential property with new landscaping and
replacement trees within the setback area, which will provide a buffer and added privacy
for the adjacent residential property. The existing club house building is not part of the
scope of work and will be maintained with no change to building height, footprint, color,
or design. Therefore, there will be no abrupt changes in building scale related to height and
bulk and no new buildings are being proposed.
b) In order to preserve design harmony between new and existing buildings and in
order to preserve and enhance property values, the materials, textures and colors
of new building should harmonize with adjacent development by being consistent
or compatible with design and color schemes with the future character of the
neighborhoods and purposes of the zone in which they are situated. The location,
height and materials of walls, fencing, hedges and screen planting should
harmonize with adjacent development. Unsightly storage areas, utility
installations and unsightly elements of parking lots should be concealed. The
planting of ground cover or various types of pavements should be used to prevent
dust and erosion, and the unnecessary destruction of existing healthy trees should
be avoided. Lighting for development should be adequate to meet safety
requirements as specified by the engineering and building departments and
provide shielding to prevent spill-over light to adjoining property owners.
The exterior and landscape modifications are harmonious with the existing building form
and are compatible with recent design upgrades to the adjacent Arioso Apartment
residential towers and the Courtyard by Marriot hotel. The neutral color palette of the
ASA-2020-006, TR-2020-044 19608 Pruneridge Ave. March 11, 2021
Page 9
design will also be well-suited with the adjacent single-family residential properties.
Furthermore, potential impacts to adjacent single-family residential properties will be
mitigated by maintaining appropriate setbacks for the trellises and the installation of
required replacement trees and proposed landscape enhancements. The proposed upgrades
to the existing materials and colors will therefore not impact the future character of the
neighborhood. The project avoids the unnecessary destruction of existing healthy trees on
site. The proposed tree removals are due to poor health and initial planting locations that
are not suitable for the continued maintenance of the trees. The proposed tree replacements
exceed the Cupertino Municipal Code requirements and will improve the aesthetics of the
site for its users. New landscaping is being proposed to enhance existing landscaping at
the site and promote native ground cover. The proposed lighting fixtures are designed to
prevent spill-over light to adjoining properties.
c) The number, location, color, size, height, lighting and landscaping of outdoor
advertising signs and structures have been designed to minimize traffic hazard,
positively affect the general appearance of the neighborhood and harmonize with
adjacent development.
No signs are proposed as part of this project.
d) With respect to new projects within existing residential neighborhoods, new
development should be designed to protect residents from noise, traffic, light and
visually intrusive effects by use of buffering, setbacks, landscaping, walls and
other appropriate design measures.
This application is not a new development project.
With respect to the Tree Removal Permit, the following findings may be made:
3. That the protected trees are a detriment to the subject property and cannot be
adequately supported according to good urban forestry practices due to the
overplanting or overcrowding of trees on the subject property.
The proposed tree removals are due to poor initial planting locations that are not suitable for
the continued maintenance of the trees. The proposed tree replacements and locations for
replacement will improve the aesthetics of the site for its users. The City’s consulting arborist
has reviewed the arborist report and takes no exception to the proposal for removal.
Next Steps
The permit will become effective 14 calendar days from the date of the hearing. The
decision of the Administrative Hearing Officer is final, unless appealed within 14
calendar days from the date of the hearing. The applicant team may apply for building
ASA-2020-006, TR-2020-044 19608 Pruneridge Ave. March 11, 2021
Page 10
and/or other permits with the City at the end of the appeal period (March 25, 2021 at
5:00pm).
This approval is valid until March 11, 2023. The applicant team may apply for a one-time
two-year extension before the approval expires.
Prepared by: Erika Poveda, Associate Planner
Reviewed and Approved for submission by: Piu Ghosh, Planning Manager
ATTACHMENTS
1. Draft Resolution for ASA-2020-006
2. Draft Resolution for TR-2020-044
3. Plan Set
4. Arborist Report
ASA-2020-006
CITY OF CUPERTINO
10300 Torre Avenue
Cupertino, California 95014
DRAFT RESOLUTION
OF THE ADMINISTRATIVE HEARING OFFICER OF THE CITY OF
CUPERTINO APPROVING AN ARCHITECTURAL AND SITE PERMIT
TO ALLOW EXTERIOR AND LANDSCAPE MODIFICATIONS TO THE
EXISTING POOL DECK AREA AT ARIOSO APARTMENTS LOCATED
AT 19608 PRUNERIDGE AVENUE
SECTION I: PROJECT DESCRIPTION
Application No.: ASA-2020-006
Applicant: Tim Barnes (Studio G Architects, Inc.)
Location: 19608 Pruneridge Avenue (APN 316-45-016)
SECTION II: FINDINGS
WHEREAS, the City of Cupertino received an application for an Architectural and Site
Approval to consider allowing modifications to the existing pool deck and landscaping
for an existing multi-family residential complex, as described in Section I. of this
Resolution; and
WHEREAS, the necessary public notices have been given as required by the Procedural
Ordinance of the City of Cupertino, and the Administrative Hearing Officer has held at
least one public meeting with regard to the application; and
WHEREAS, pursuant to the provisions of the California Environmental Quality Act of
1970 (Public Resources Code section 21000 et seq.) (“CEQA”), together with the State
CEQA Guidelines (California Code of Regulations, Title 14, Section 15000 et seq.)
(hereinafter, "CEQA Guidelines"), the City staff has independently studied the proposed
Project and has determined that the Project is exempt from environmental review
pursuant to the categorical exemption in CEQA Guidelines section 15301 for the reasons
set forth in the staff report dated March 11, 2021 and incorporated herein; and
WHEREAS, the applicant has met the burden of proof required to support said
application; and
WHEREAS, the Administrative Hearing Officer finds as follows with regard to this
application:
Draft Resolution ASA-2020-006 March 11, 2021
Page 2
1. The proposal, at the proposed location, will not be detrimental or injurious to property
or improvements in the vicinity, and will not be detrimental to the public health,
safety, general welfare, or convenience;
The proposal includes exterior and landscape modifications to the existing pool deck area of the
Arioso Apartment complex that modernize and maximize the usability of the amenity space.
The exterior enhancements will incorporate small private gathering spaces and additional
textures and finishes, including 100% recycled wood decking, low-maintenance weathered
steel (cor-ten) trellises, contemporary wood seating and lounging options, and native
landscaping. The proposal includes minor improvements to an existing use. No changes to the
location of the use is being proposed. Potential impacts to an adjacent single-family residential
property will be mitigated by setbacks, the installation of required replacement trees and
proposed landscape enhancements. Therefore, the exterior and landscape modifications will not
be detrimental or injurious to property or improvements in the vicinity, and will not be
detrimental to the public health, safety, general welfare, or convenience.
2. The proposal is consistent with the purposes of Chapter 19.168, the General Plan any
specific plan, zoning ordinances, applicable planned development permit, conditional
use permits, variances, subdivision maps or other entitlements to use which regulate
the subject property including, but not limited to, adherence to the following specific
criteria:
a) Abrupt changes in building scale should be avoided. A gradual transition related
to height and bulk should be achieved between new and existing buildings.
The project scope does not include the modification or addition of buildings. The proposed
12-foot tall trellises are considered unenclosed accessory structures. The northerly trellis
abuts the Arioso Apartment complex parking lot. The southerly trellis will be set back 10’-
6” from the closest adjacent single-family residential property with new landscaping and
replacement trees within the setback area, which will provide a buffer and added privacy
for the adjacent residential property. The existing club house building is not part of the
scope of work and will be maintained with no change to building height, footprint, color,
or design. Therefore, there will be no abrupt changes in building scale related to height and
bulk and no new buildings are being proposed.
b) In order to preserve design harmony between new and existing buildings a nd in
order to preserve and enhance property values, the materials, textures and colors
of new building should harmonize with adjacent development by being consistent
or compatible with design and color schemes with the future character of the
neighborhoods and purposes of the zone in which they are situated. The location,
height and materials of walls, fencing, hedges and screen planting should
Draft Resolution ASA-2020-006 March 11, 2021
Page 3
harmonize with adjacent development. Unsightly storage areas, utility
installations and unsightly elements of parking lots should be concealed. The
planting of ground cover or various types of pavements should be used to prevent
dust and erosion, and the unnecessary destruction of existing healthy trees should
be avoided. Lighting for development should be adequate to meet safety
requirements as specified by the engineering and building departments and
provide shielding to prevent spill-over light to adjoining property owners.
The exterior and landscape modifications are harmonious with the existing building form
and are compatible with recent design upgrades to the adjacent Arioso Apartment
residential towers and the Courtyard by Marriot hotel. The neutral color palette of the
design will also be well-suited with the adjacent single-family residential properties.
Furthermore, potential impacts to adjacent single-family residential properties will be
mitigated by maintaining appropriate setbacks for the trellises and the installation of
required replacement trees and proposed landscape enhancements. The proposed upgrades
to the existing materials and colors will therefore not impact the future character of the
neighborhood. The project avoids the unnecessary destruction of existing healthy trees on
site. The proposed tree removals are due to poor health and initial planting locations that
are not suitable for the continued maintenance of the trees. The proposed tree replacements
exceed the Cupertino Municipal Code requirements and will improve the aesthetics of the
site for its users. New landscaping is being proposed to enhance existing landscaping at
the site and promote native ground cover. The proposed lighting fixtures are designed to
prevent spill-over light to adjoining properties.
c) The number, location, color, size, height, lighting and landscaping of outdoor
advertising signs and structures have been designed to minimize traffic hazard,
positively affect the general appearance of the neighborhood and harmonize with
adjacent development.
No signs are proposed as part of this project.
d) With respect to new projects within existing residential neighborhoods, new
development should be designed to protect residents from noise, traffic, light and
visually intrusive effects by use of buffering, setbacks, landscaping, wal ls and
other appropriate design measures.
This application is not a new development project.
NOW, THEREFORE, BE IT RESOLVED:
That after careful consideration of the maps, facts, exhibits, testimony, staff’s report and
presentation, and other evidence submitted in this matter, subject to the conditions which
are enumerated in this Resolution beginning on PAGE 4 thereof,
Draft Resolution ASA-2020-006 March 11, 2021
Page 4
The application for an Architectural and Site Approval, Application no. ASA-2020-006 is
hereby approved and that the subconclusions upon which the findings and conditions
specified in this resolution are based and contained in the Public Meeting record
concerning Application no. ASA-2020-006 as set forth in the Minutes of the
Administrative Hearing Meeting of March 11, 2021 and are incorporated by reference as
though fully set forth herein.
SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT
DEPARTMENT
1. APPROVED EXHIBITS
Approval is based on the plan set drawn by Studio G Architects, titled “Pool Deck
Remodel for Arioso Apartments – 19608 Pruneridge Ave., Cupertino, CA 95014”
consisting of 30 sheets labeled A0.0, A0.1, AS.1, AS.2, AS.3, AS.4, AS.5, AS.6, C4.0,
L1.0, L1.1, L1.2, L1.3, L1.4, L1.4A, L2.1, L3.0, L3.2, L3.3, L3.4, L3.5, L3.6, L3.7, L4.1,
L4.2, L5.1, L5.2, LD.1, LD.2 and LD.3, except as may be amended by conditions in
this resolution.
2. ACCURACY OF PROJECT PLANS
The applicant/property owner is responsible to verify all pertinent property data
including but not limited to property boundary locations, building setbacks,
property size, building square footage, any relevant easements and/or
construction records. Any misrepresentation of any property data may invalidate
this approval and may require additional review.
3. ANNOTATION OF THE CONDITIONS OF APPROVAL
The conditions of approval set forth shall be incorporated into and annotated on
the first page of the building plans.
4. BUILDING AND FIRE CODE
The applicant shall apply for and obtain building permits to allow the construction
of the approved project. The applicant shall provide information and plans to
allow the Building Official and the Fire Marshall, or their designee, to determine
that the proposed plans comply with Building and Fire Codes in effect at the time
of application for a building permit.
5. CONSULTATION WITH OTHER DEPARTMENTS
The applicant is responsible to consult with other departments and/or agencies
with regard to the proposed project for additional conditions and requirements.
Any misrepresentation of any submitted data may invalidate an approval by the
Community Development Department.
Draft Resolution ASA-2020-006 March 11, 2021
Page 5
6. CONCURRENT APPROVAL CONDITIONS
The conditions of approval contained in file no. TR-2020-044 shall be applicable to
this approval.
7. DEMOLITION REQUIREMENTS
All demolished building and site materials shall be recycled to the maximum
extent feasible subject to the Building Official. The applicant shall provide
evidence that materials were recycled prior to occupancy.
8. DUST CONTROL
The following construction practices shall be implemented during all phases of
construction for the proposed project to prevent visible dust emissions from
leaving the site:
a. Water all exposed surfaces areas (e.g., parking areas, staging areas, soil piles,
graded areas, and unpaved access roads) at least twice daily and more often
during windy periods to prevent visible dust from leaving the site; active areas
adjacent to windy periods; active areas adjacent to existing land uses shall be
kept damp at all times, or shall be treated with non-toxic stabilizers or dust
palliatives.
b. All haul trucks transporting soil, sand, or other loose material off-site shall be
covered.
c. All visible mud or dirt track-out onto adjacent public roads shall be removed
using wet power vacuum street sweepers at least once per day. The use of dry
power sweeping is prohibited.
d. All vehicle speeds on unpaved roads shall be limited to 15 mph.
e. All roadways, driveways, and sidewalks to be paved shall be complet ed as
soon as possible. Building pads shall be laid as soon as possible after grading
unless seeding or soil binders are used.
f. Idling times shall be minimized either by shutting equipment off when not in
use or reducing the maximum idling time to 5 minutes (as required by the
California airborne toxics control measure Title 13, Section 2485 of California
Code of Regulations [CCR]). Clear signage shall be provided for construction
workers at all access points.
g. All construction equipment shall be maintained and properly tuned in
accordance with manufacturer’s specifications. All equipment shall be checked
by a certified mechanic and determined to be running in proper condition prior
to operation.
h. Post a publicly visible sign with the telephone number and person to contact
at the Lead Agency regarding dust complaints. This person shall respond and
Draft Resolution ASA-2020-006 March 11, 2021
Page 6
take corrective action within 48 hours. The Air District’s phone number shall
also be visible to ensure compliance with applicable regulations.
The applicant shall incorporate the City’s construction best management practices
into the building permit plan set prior to any grading, excavation , foundation or
building permit issuance.
9. EXTERIOR BUILDING MATERIALS/TREATMENTS
The final building exterior plan shall closely resemble the details shown on the
original approved plans. Final building exterior treatment plan (including but not
limited to details on exterior color, materials, architectural treatments, doors,
windows, lighting fixtures, and/or embellishments) shall be reviewed and
approved by the Director of Community Development prior to issuance of
building permits to ensure quality and consistency. Any exterior changes
determined to be substantial by the Director of Community Development shall
either require a modification to this permit or a new permit based on the extent of
the change.
10. OUTDOOR LIGHTING
All outdoor lighting shall be downward directed and shielded. Uplighting for
trees shall be low voltage. Lighting shall be turned off after 11:00 p.m. or when
people are no longer present, whichever occurs later, except lighting required for
security purposes. Lighting spillover is not allowed onto neighboring properties.
11. GRADING AND CONSTRUCTION HOURS AND NOISE LIMITS
a. All grading activities shall be limited to the dry season (April 15 to October 1),
unless permitted otherwise by the Director of Public works.
b. Construction hours and noise limits shall be compliant with all requirements
of Chapter 10.48 of the Cupertino Municipal Code.
c. Grading, street construction, underground utility and demolition hours for
work done more than 750 feet away from residential areas shall be limited to
Monday through Friday, 7 a.m. to 8 p.m. and Saturday and Sunday, 9 a.m. to
6 p.m. Grading, street construction, demolition or underground utility work
within 750 feet of residential areas shall not occur on Saturdays, Sundays,
holidays, and during the nighttime period as defined in Section 10.48.053(b) of
the Municipal Code.
d. Construction activities shall be limited to Monday through Friday, 7 a.m. to 8
p.m. and Saturday and Sunday, 9 a.m. to 6 p.m. Construction activities are not
allowed on holidays as defined in Chapter 10.48 of the Municipal Code. Night
Draft Resolution ASA-2020-006 March 11, 2021
Page 7
time construction is allowed if compliant with nighttime standards of Section
10.48 of the Cupertino Municipal Code.
e. Rules and regulations pertaining to all construction activities and limitations
identified in this permit, along with the name and telephone number of an
applicant appointed disturbance coordinator, shall be posted in a prominent
location at the entrance to the job site.
f. The applicant shall be responsible for educating all contractors and
subcontractors of said construction restrictions.
The applicant shall comply with the above grading and construction hours and
noise limit requirements unless otherwise indicated.
12. LANDSCAPE PROJECT SUBMITTAL
Prior to issuance of building permits, the applicant shall submit a full Landscape
Documentation Package, per sections 14.15.050 A, B, C, and D of the Landscape
Ordinance, for projects with landscape area 500 square feet or more or elect to
submit a Prescriptive Compliance Application per sections 14.15.040 A, B, and C
for projects with landscape area between 500 square feet and 2,500 square feet.
The Landscape Documentation Package or Prescriptive Compliance Application
shall be reviewed and approved to the satisfaction of the Director of Community
Development prior to issuance of building permits, and additional requirements
per sections 14.15.040 D, E, F, and G or 14.15.050 E, F, G, H, and I will be required
to be reviewed and approved prior to final inspections.
13. NESTING BIRDS
Nests of raptors and other birds shall be protected when in active use, as required
by the federal Migratory Bird Treaty Act and the California Department of Fish
and Game Code.
a. Construction and tree removal/pruning activities shall be scheduled to avoid
the nesting season to the extent feasible. If feasible, tree removal and/or
pruning shall be completed before the start of the nesting season to help
preclude nesting. The nesting season for most birds and raptors in the San
Francisco Bay area extends from February 1 through August 31.
Preconstruction surveys (described below) are not required for tree removal or
construction activities outside the nesting period.
b. If construction activities and any required tree removal occur during the
nesting season (February 1 and August 31), a qualified ornithologist shall be
required to conduct surveys prior to tree removal or construction activities.
Preconstruction surveys shall be conducted no more than 14 days prior to the
start of tree removal, pruning or construction. Preconstruction surveys shall be
Draft Resolution ASA-2020-006 March 11, 2021
Page 8
repeated at 14-day intervals until construction has been initiated in the area
after which surveys can be stopped. During this survey, the ornithologist shall
inspect all trees and other possible nesting habitats in and immediately
adjacent to the construction areas for nests.
c. If the survey does not identify any nesting birds that would be affected by
construction activities, no further mitigation is required. If an active nest
containing viable eggs or young birds is found sufficiently close to work areas
to be disturbed by these activities, their locations shall be documented and
protective measures implemented under the direction of the qualified
ornithologist until the nests no longer contain eggs or young birds.
d. Protective measures shall include establishment of clearly delineated exclusion
zones (i.e. demarcated by identifiable fencing, such as orange construction
fencing or equivalent) around each nest location as determined by the qualified
ornithologist, taking into account the species of birds nesting, their tolerance
for disturbance and proximity to existing development. In general, exclusion
zones shall be a minimum of 300 feet for raptors and 75 feet for passerines and
other birds. The active nest within an exclusion zone shall be monitored on a
weekly basis throughout the nesting season to identify signs of disturbance and
confirm nesting status. The radius of an exclusion zone may be increased by
the qualified biologist, if project activities are determined to be adversely
affecting the nesting birds. Exclusion zones may be reduced by the qualified
biologist only in consultation with California Department of Fish and Wildlife.
The protection measures and buffers shall remain in effect until the young have
left the nest and are foraging independently or the nest is no longer active.
e. A final report on nesting birds and raptors, including survey methodology,
survey date(s), map of identified active nests (if any), and protection measures
(if required), shall be submitted to the Planning Manager, through the building
permit review process, and be completed to the satisfaction of the Community
Development Director prior to the start of grading.
14. SIGNAGE
Signage is not approved with this application. Signage shall conform to the City
Sign Code.
15. TREE AND LANDSCAPE MAINTENANCE
The property owner shall be responsible for ensuring that the existing trees and
newly planted trees are properly maintained including but not limited to ensuring
that there is adequate soil drainage, that the soil is well -aerated, and irrigation
systems are thoroughly tested to provide sufficient water to landscaped areas
while reducing water waste.
Draft Resolution ASA-2020-006 March 11, 2021
Page 9
16. TREE PROTECTION
As part of the demolition or building permit drawings, a tree protection plan shall
be prepared by a certified arborist for the trees to be retained. In addition, the
following measures shall be added to the protection plan:
For trees to be retained, chain link fencing and other root protection shall be
installed around the dripline of the tree prior to any project site work.
No parking or vehicle traffic shall be allowed under root zones, unless using
buffers approved by the Project Arborist.
No trenching within the critical root zone area is allowed. If trenching is
needed in the vicinity of trees to be retained, the City’s consulting arborist shall
be consulted before any trenching or root cutting beneath the dripline of the
tree.
Wood chip mulch shall be evenly spread inside the tree projection fence to a
four-inch depth.
Tree protection conditions shall be posted on the tree protection barriers.
Retained trees shall be watered to maintain them in good health.
A covenant on the property shall be recorded that identifies all the protected
trees, prior to final occupancy.
The tree protection measures shall be inspected and approved by the certified
arborist prior to issuance of building permits. The City’s consulting arborist shall
inspect the trees to be retained and shall provide reviews prior to issuance of
demolition, grading or building permits. A report ascertaining the good health of
the trees mentioned above shall be provided prior to issuance of final occupancy.
17. INDEMNIFICATION
As part of the application, to the fullest extent permitted by law, the applicant shall
agree to indemnify, defend with the attorneys of the City’s choice, and hold
harmless the City, its City Council, and its officers, employees, and agents
(collectively, the “indemnified parties”) from and against any liability, claim,
action, cause of action, suit, damages, judgment, lien, levy, or proceeding
(collectively referred to as “proceeding”) brought by a third party against one or
more of the indemnified parties or one or more of the indemnified parties and the
applicant related to any Ordinance, Resolution, or action approving the project,
the related entitlements, environmental review documents, finding or
determinations, or any other permit or approval authorized fo r the project. The
indemnification shall include but not be limited to damages, fees, and costs
awarded against the City, if any, and cost of suit, attorneys’ fees, and other costs,
liabilities, and expenses incurred in connection with such proceeding whether
Draft Resolution ASA-2020-006 March 11, 2021
Page 10
incurred by the Applicant, the City, or the parties initiating or bringing such
proceeding.
The applicant shall agree to (without limitation) reimburse the City its actual
attorneys’ fees and costs incurred in defense of the litigation. Such attorneys’ fees
and costs shall include amounts paid to the City’s outside counsel and shall
include City Attorney time and overhead costs and other City staff overhead costs
and any costs directly related to the litigation reasonably incurred by City . The
applicant shall likewise agree to indemnify, defend, and hold harmless the
indemnified parties from and against any damages, attorneys’ fees, or costs
awards, including attorneys’ fees awarded under Code of Civil Procedure section
1021.5, assessed or awarded against the indemnified parties. The Applicant shall
cooperate with the City to enter a Reimbursement Agreement to govern any such
reimbursement.
The Applicant shall agree to (without limitation) reimburse the City for all costs
incurred in additional investigation or study of, or for supplementing, redrafting,
revising, or amending, any document (such as an Environmental Impact Report,
negative declaration, specific plan, or general plan amendment) if made necessary
by proceedings challenging the project approvals and related environmental
review, if the applicant desires to continue to pursue the project.
The Applicant shall agree that the City shall have no liability to the Applicant for
business interruption, punitive, speculative, or consequential damages.
18. NOTICE OF FEES, DEDICATIONS, RESERVATIONS, OR OTHER EXACTIONS
The Conditions of Project Approval set forth herein may include certain fees,
dedication requirements, reservation requirements, and other exactions.
PASSED AND ADOPTED this 11th day of March 2021 at a noticed Public Meeting of the
Administrative Hearing Officer of the City of Cupertino, State of California, held by the
Director of Community Development, or his or her designee, pursuant to Cupertino
Municipal Code Section 19.12.120.
ATTEST: APPROVED:
Erika Poveda Albert Salvador
Associate Planner Assistant Director of Community Development
TR-2020-044
CITY OF CUPERTINO
10300 Torre Avenue
Cupertino, California 95014
DRAFT RESOLUTION
OF THE ADMINISTRATIVE HEARING OFFICER OF THE CITY OF
CUPERTINO APPROVING A TREE REMOVAL PERMIT TO ALLOW
THE REMOVAL AND REPLACEMENT OF FOUR
PROTECTED TREES LOCATEDAT 19608 PRUNERIDGE AVENUE
SECTION I: PROJECT DESCRIPTION
Application No.: TR-2020-044
Applicant: Tim Barnes (Studio G Architects, Inc.)
Location: 19608 Pruneridge Avenue (APN 316-45-016)
SECTION II: FINDINGS TREE REMOVAL PERMIT:
WHEREAS, the City of Cupertino received an application for a Tree Removal permit as
described in Section I of this Resolution; and
WHEREAS, the necessary public notices have been given as required by the Procedural
Ordinance of the City of Cupertino, and the Administrative Hearing Officer has held at
least one public meeting in regard to the application; and
WHEREAS, pursuant to the provisions of the California Environmental Quality Act of
1970 (Public Resources Code section 21000 et seq.) (“CEQA”), together with the State
CEQA Guidelines (California Code of Regulations, Title 14, Section 15000 et seq.)
(hereinafter, "CEQA Guidelines"), the City staff has independently studied the proposed
Project and has determined that the Project is exempt from environmental review
pursuant to the categorical exemption in CEQA Guidelines section 15304 for the reasons
set forth in the staff report dated March 11, 2021 and incorporated herein; and
WHEREAS, the applicant has met the burden of proof required to support said
application; and
WHEREAS, the Administrative Hearing Officer finds as follows with regard to this
application:
1. That the protected trees are a detriment to the subject property and cannot be
adequately supported according to good urban forestry practices due to the
overplanting or overcrowding of trees on the subject property.
Draft Resolution TR-2020-044 March 11, 2021
Page 2
The proposed tree removals are due to poor initial planting locations that are not suitable for
the continued maintenance of the trees. The proposed tree replacements and locations for
replacement will improve the aesthetics of the site for its users. The City’s consulting arborist
has reviewed the arborist report and takes no exception to the proposal for removal.
NOW, THEREFORE, BE IT RESOLVED:
That after careful consideration of the maps, facts, exhibits, testimony, staff’s report and
presentation, and other evidence submitted in this matter, subject to the conditions which
are enumerated in this Resolution beginning on PAGE 2 thereof:
The application for a Tree Removal permit, Application no. TR-2020-044 is hereby
approved and that the subconclusions upon which the findings and conditions specified
in this resolution are based and contained in the Public Meeting record concerning
Application no. TR-2020-044 as set forth in the Minutes of the Administrative Hearing
Meeting of March 11, 2021 and are incorporated by reference as though fully set forth
herein.
SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY
DEVELOPMENT DEPT.
1. APPROVED EXHIBITS
This approval for tree removal is based on the certified arborist report prepared by
Richard Gessner (ISA Certified Arborist, WE-4341B) with Monarch Consulting
Arborists, dated August 10, 2020 and consisting of 21 pages; and the tree removal and
replacement plans drawn by Studio G. Architects and TS Studio, consisting of two (2)
pages labeled L4.1 and LD.2, except as may be amended by conditions in this
resolution.
2. ACCURACY OF PROJECT PLANS
The applicant/property owner is responsible to verify all pertinent property data
including but not limited to property boundary locations, building setbacks, property
size, building square footage, any relevant easements and/or construction records.
Any misrepresentation of any property data may invalidate this approval and may
require additional review.
3. CONCURRENT APPROVAL CONDITIONS
The conditions of approval contained in file no. ASA-2020-006 shall be applicable to
this approval.
Draft Resolution TR-2020-044 March 11, 2021
Page 3
4. TREE AND LANDSCAPE MAINTENANCE
The property owner shall be responsible for ensuring that the existing trees and newly
planted trees are properly maintained including but not limited to ensuring that there
is adequate soil drainage, that the soil is well-aerated, and irrigation systems are
thoroughly tested to provide sufficient water to landscaped areas while reducing
water waste.
5. TREE REPLACEMENTS
The applicant is required to plant replacement trees in accordance with the Protected
Tree Ordinance and per the approved replacement plan. In the event changes to the
replacement tree species, sizes, or locations are proposed, the revised planting plan
shall be reviewed and approved prior to issuance of building permits by the Director
of Community Development and in consultation with the City’s Consultant Arborist,
if it is determined if the approved replacement plan is not feasible for any reason.
6. TREE PROTECTION
As part of the demolition or building permit drawings, a tree protection plan shall be
prepared by a certified arborist for the trees to be retained. In addition, the following
measures shall be added to the protection plan:
For trees to be retained, chain link fencing and other root protection shall be
installed around the dripline of the tree prior to any project site work.
Signs indicating the protected status of the tree shall be installed on the protective
fencing.
Tree protection conditions shall be posted on the tree protection fencing.
No parking or vehicle traffic shall be allowed under root zones, unless using
buffers approved by the Project Arborist.
No trenching within the critical root zone area is allowed. If trenching is needed
in the vicinity of trees to be retained, the City’s consulting arborist shall be
consulted before any trenching or root cutting beneath the dripline of the tree.
Wood chip mulch shall be evenly spread inside the tree projection fence to a four-
inch depth.
Retained trees shall continue to be irrigated or hand-watered to maintain them in
good health.
The tree protection measures shall be inspected and approved by the certified arborist
prior to issuance of building permits. The City’s consulting arborist shall inspect the
trees to be retained and shall provide reviews prior to issuance of demolition, grading
or building permits. Additionally, a report ascertaining the good health of the trees
mentioned above shall be provided prior to issuance of final occupancy. Any trees
Draft Resolution TR-2020-044 March 11, 2021
Page 4
identified to be in poor health or incongruent with the site-wide tree replacement plan
in the report shall be required to be removed and replaced.
7. INDEMNIFICATION
As part of the application, to the fullest extent permitted by law, the applicant shall
agree to indemnify, defend with the attorneys of the City’s choice, and hold harmless
the City, its City Council, and its officers, e mployees, and agents (collectively, the
“indemnified parties”) from and against any liability, claim, action, cause of action,
suit, damages, judgment, lien, levy, or proceeding (collectively referred to as
“proceeding”) brought by a third party against one or more of the indemnified parties
or one or more of the indemnified parties and the applicant related to any Ordinance,
Resolution, or action approving the project, the related entitlements, environmental
review documents, finding or determinations, or any other permit or approval
authorized for the project. The indemnification shall include but not be limited to
damages, fees, and costs awarded against the City, if any, and cost of suit, attorneys’
fees, and other costs, liabilities, and expenses incurred in connection with such
proceeding whether incurred by the Applicant, the City, or the parties initiating or
bringing such proceeding.
The applicant shall agree to (without limitation) reimburse the City its actual
attorneys’ fees and costs incurred in defense of the litigation. Such attorneys’ fees and
costs shall include amounts paid to the City’s outside counsel and shall include City
Attorney time and overhead costs and other City staff overhead costs and any costs
directly related to the litigation reasonably incurred by City. The applicant shall
likewise agree to indemnify, defend, and hold harmless the indemnified parties from
and against any damages, attorneys’ fees, or costs awards, including attorneys’ fees
awarded under Code of Civil Procedure section 1021.5, assessed or awarded against
the indemnified parties. The Applicant shall cooperate with the City to enter a
Reimbursement Agreement to govern any such reimbursement.
The Applicant shall agree to (without limitation) reimburse the City for all costs
incurred in additional investigation or study of, or for supplementing, redrafting,
revising, or amending, any document (such as an Environmental Impact Report,
negative declaration, specific plan, or general plan amendment) if made necessary by
proceedings challenging the project approvals and related environmental review, if
the applicant desires to continue to pursue the project.
The Applicant shall agree that the City shall have no liability to the Applicant for
business interruption, punitive, speculative, or consequential damages.
Draft Resolution TR-2020-044 March 11, 2021
Page 5
8. NOTICE OF FEES, DEDICATIONS, RESERVATIONS, OR OTHER EXACTIONS
The Conditions of Project Approval set forth herein may include certain fees,
dedication requirements, reservation requirements, and other exactions.
PASSED AND ADOPTED this 11th day of March 2021 at a noticed Public Meeting of the
Administrative Hearing Officer of the City of Cupertino, State of California, held by the
Director of Community Development, or his or her designee, pursuant to Cupertino
Municipal Code Section 19.12.120.
ATTEST: APPROVED:
Erika Poveda Albert Salvador
Associate Planner Assistant Director of Community Development
SCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250SAN JOSE, CA 95110T:408.283.0100 ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTEN MATERIALS INDICATED HEREIN ARE THE WORK AND PROPERTY OF STUDIO G ARCHITECTS. THIS DOCUMENT MAY NOT BE DUPLICATED, REUSED OR DISCLOSED BY ANY METHOD WITHOUT THE WRITTEN CONSENT OF STUDIO G ARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESS12/14/2020 8:24:54 PMA0.0COVER SHEETPOOL DECK IMPROVEMENTS forKL08/06/20202017.15019608 Pruneridge AveCupertino, CA 95014POOL DECK REMODEL FOR 19608 PRUNERIDGE AVE, CUPERTINO, CA 95014A.P.N.316-47-018ZONINGP (CG, RES)DESIGNATED LAND USECOMMERCIAL, RESIDENTIALCONSTRUCTION TYPECLUBHOUSE BUILDING: V-BSITE AREA305,355 SF (± 7.01 AC) APARTMENT UNIT COUNT201TOTAL BUILDING AREA230,501 (EXISTING AND PROPOSED)FLOOR AREA RATIO0.75 (EXISTING AND PROPOSED)LOT COVERAGE0.25 (EXISTING AND PROPOSED)EXISTING PATIO AREA:±3,488 SFPROJECT AREA (NEW PATIO)±3,400 SFAPPLICABLE CODES2019 CALIFORNIA BUILDING CODE2019 CALIFORNIA ELECTRICAL CODE2019 CALIFORNIA MECHANICAL CODE2019 CALIFORNIA PLUMBING CODE2019 CALIFORNIA ENERGY CODE2019 CALIFORNIA FIRE CODE2019 CALGREEN CODEALL APPLICABLE LOCAL, COUNTY, STATE AND FEDERAL CODES, LAWS AND REGULATIONS.ARIOSO APARTMENTSPROJECT DIRECTORYTHIS PROJECT INCLUDES REMODELING OF AN EXISTING POOL DECK, INCLUDING SHADE STRUCTURES, BARBEQUE, AND SHADE STRUCTURES.IMPERMEABLE AREA IMPACTED FALLS BELOW C.3 LIMITS, SEE CIVIL, SEE LANDSCAPE DRAWINGS.PROJECT LOCATIONPRELIMINARY(NOT FOR CONSTRUCTION)HEALTH DEPARTMENT(NOT FOR CONSTRUCTION)PRICING PLANS(NOT FOR CONSTRUCTION)BUILDING SUBMITTALGENERALCIVILVICINITY MAPPROJECT INFORMATIONSCOPE OF WORKSHEET INDEXPLANNING DEPARTMENT(NOT FOR CONSTRUCTION)CONTRACTOR:URC WEST, INC.NATE JOHNSTON, DIRECTOR OF CONSTRUCTION1122 N.MELROSE DR. VISTA, CA 92083P(M): 760.277.0193P(O): 760.451.8921 ARCHITECT:STUDIO G ARCHITECTS, INC.KELLY SIMCOXTIM BARNES299 BASSETT ST. SUITE 250SAN JOSE, CA 95110P: 408.283.0100x13E: tim@studiogarchitectsinc.comLANDSCAPE ARCHITECT:TS STUDIOJ. LEE STICKLES55 SUMNER ST.SAN FRANCISCO, CA 94103P: 415.596.2121E: lstickles@tsstudio.orgAS.1 EXISTING SITE PLAN (FOR REFERENCE ONLY)AS.2 EXISTING PARKING PLAN (FOR REFERENCE ONLY)AS.3 KEY SITE PLANAS.4 ENLARGED SITE PLANAS.5 EXISTING SITE IMAGES ( FOR REFERENCE ONLY)AS.6 SITE DETAILSL1.0 LANDSCAPE SITE PLANLD.1 LANDSCAPE DEMO PLANLD.2 TREE DISPOSITION PLANLD.3 TREE PROTECTION DETAILSL1.1 LANDSCAPE LAYOUT PLANL1.2 LANDSCAPE MATERIAL PLANL1.3 LANDSCAPE FURNITURE PLANL1.4 LANDSCAPE LIGHTING PLANL1.4A LANDSCAPE LIGHTING CALCSL2.1 LANDSCAPE GRADING PLANL3.0 IRRIGATION LAYOUT PLANL3.2 IRRIGATION DETAILSL3.3 IRRIGATION DETAILSL3.4 IRRIGATION NOTESL3.5 IRRIGATION NOTESL3.6 WATER USE CALCULATIONSL3.7 HYDROZONE LAYOUTL4.1 LANDSCAPE PLANTING PLANL4.2 LANDSCAPE PLANTING IMAGESL5.1 LANDSCAPE SECTIONSL5.2 LANDSCAPE PERSPECTIVEC4.0 UTILITY PLANA0.0 COVER SHEETA0.1 GENERAL NOTES, ABBREVIATIONS & LEGENDSOWNER:CIM GROUPANDRE HERRINGONE KAISER PLAZAOAKLAND, CA 94612P: 510.992.6190E: aherring@cimgroup.comPARKING SUMMARYNO. DATE DESCRIPTION08/06/2020 PLANNING SETPARKING COUNTS ARE UNCHANGED FROM EXISTING PERMITTED CONDITIONS. SEE CIVIL SHEET 1.LANDSCAPEARCHITECTURALCIVIL ENGINEER:HOHBACH-LEWIN, INC.BILL HENN260 SHERIDAN AVE. #150PALO ALTO, CA 94306P: 650.617.5930E: BHenn@hohbach-lewin.com
A.B. ANCHOR BOLTA.C. ASPHALT CONCRETEA/C AIR CONDITIONINGA.F.F. ABOVE FINISH FLOORA.T. ACOUSTIC TILEADJ. ADJUSTABLEA.F.S. AUTOMATIC FIRE SPRINKLERALUM. ALUMINUM∠ANGLEANOD. ANODIZEDAPPROX. APPROXIMATELYARCH. ARCHITECTURALASPH. ASPHALT@ATBD. BOARDBLDG. BUILDINGBLKG. BLOCKINGBM. BEAMB.O.J. BOTTOM OF JOISTSBOT. BOTTOMB.U. BUILT-UPCAB. CABINETCAD. PL. CADMIUM PLATEDC.B. CATCH BASIN (SITE)C.B. CHALKBOARD C.D. CUP DISPENSERCEM. CEMENTCER. CERAMICC.G. CORNER GUARDCHANNELC.I. CAST IRONC.J. CONSTRUCTION JOINTC or C.L. CENTER LINECLR. CLEARCLG. CEILINGC.M.U. CONCRETE MASONRY UNITC.O. CLEANOUTCOL. COLUMNCOMP. COMPOSITIONCONC. CONCRETECONN. CONNECTIONCONT. CONTINUOUSCONTR. CONTRACTORC.O.T.G. CLEAN OUT TO GRADECTSK. COUNTERSUNKC.W. COLD WATERDET. DETAILD.F. DOUGLAS FIRD.F. DRINKING FOUNTAINDIA. DIAMETERDIM. DIMENSIONDN. DOWNDR. DOORD.S. DOWNSPOUTDWGS. DRAWINGSEA. EACHE.J. EXPANSION JOINTELECT. ELECTRICALELEV. ELEVATIONENAM. ENAMELENCL. ENCLOSUREE.P.B. ELECTRIC PANEL BOARDEQ. EQUALEQUIP. EQUIPMENTE.W.C. ELECTRIC WATER COOLERE.W.H. ELECTRIC WATER HEATEREXH. EXHAUSTEXIST. or (E) EXISTINGEXT. EXTERIORF.A. FIRE ALARMF.B. FLAT BARFBRGL. FIBERGLASSF.D. FLOOR DRAINFDN. FOUNDATIONF.E. FIRE EXTINGUISHERF.E.C. FIRE EXTINGUISHER CABINETF.H. FIRE HYDRANT OR FLAT HEADF.H.C. FIRE HOSE CABINETFIN. FINISHFLR. FLOORF.O. FINISHED OPENING or FACE OFF.O.C. FACE OF CONCRETEF.O.F. FACE OF FINISHF.O.M. FACE OF MASONRYF.O.S. FACE OF STUDF.S. FLOOR SINKFTG. FOOTINGF.R.P. FIBERGLASS REINFORCED PLASTICGA. GAUGEGALV. GALVANIZE(D)G.I. GALVANIZED IRONGL. GLASSGRD. GROUND or GRADEG.S.F. GROSS SQUARE FEETG.V. GATE VALVEG.V.C.B. GATE VALVE IN CONCRETE BOXGYP. GYPSUMHDR. HEADERHDWD. HARDWOODHDWR. HARDWAREH.M. HOLLOW METALHORIZ. HORIZONTALH.P. HIGH POINTHR. HOURH.R.C. HOSE REEL CABINETH.S.B. HIGH STRENGTH BOLTHT. HEIGHTH.T.D. HANDICAP TOWEL DISPENSERHTG. HEATINGH.W. HOT WATERH.W.D. HOT WATER DISPENSERI.D. INSIDE DIAMETERINV. INVERTINSUL. INSULATIONINT. INTERIORJAN. JANITORJ.B. JUNCTION BOXJT. JOINTKIT. KITCHENK.O. KNOCK-OUTK.P. KICK PLATELAM. LAMINATE LAV. LAVATORYLKR. LOCKERL.P. LOW POINTL.S.D. LIQUID SOAP DISPENSERLT. LIGHTMAT. MATERIALMAX. MAXIMUMM.B. MACHINE BOLTMECH. MECHANICALMEMB. MEMBRANEMFR. MANUFACTURERM.H. MANHOLEMIN. MINIMUMMISC. MISCELLANEOUSM.O. MASONRY OPENINGM.S. MACHINE SCREWMTD. MOUNTEDMTL. METALMUL. MULLIONN.I.C. NOT IN CONTRACTNO. NUMBERN.S.F. NET SQUARE FEETN.T.S. NOT TO SCALEO.C. ON CENTERO.D. OUTSIDE DIAMETERO.D. OVERFLOW DRAINOFF. OFFICEO.H. OVERHEADOPNG. OPENINGOPP. OPPOSITEP.B. PANIC BARP.D.F. POWDER DRIVEN FASTENERP.H. PHILLIPS HEADP or PL. PLATEP/L PROPERTY LINEPLAS. PLASTERP.LAM. PLASTIC LAMINATEPLYWD. PLYWOODPNL. PANELPOL. POLISHEDPORC. PORCELAINPOL. POLISHEDPR. PAIRP.S.D. POWDER SOAP DISPENSERPT. POINTP.T.D. PAPER TOWEL DISPENSERPTN. PARTITIONP.V.C. POLY VINYL CHLORIDEQT. QUARRY TILER. RISERSR.A. RETURN AIRRAD. RADIUSR.C.P. REINFORCED CONCRETE PIPERD. ROUNDR.D. ROOF DRAINREC. RECESSEDREF. REFERENCEREINF. REINFORCEDREQ. REQUIREDRESIL. RESILIENTR.H. ROUND HEAD or ROBE HOOKRM. ROOMRO. ROUGH R.O. ROUGH OPENINGR/W RIGHT OF WAYRWD. REDWOODR.W.L. RAIN WATER LEADERS.C. SOLID CORES.C.D. SEAT COVER DISPENSER orSEE CIVIL DRAWINGSS.D. STORM DRAIN or SOAP DISPENSERSEC. SECTIONS.E.D. SEE ELECTRICAL DRAWINGSS.F. SQUARE FOOT/FEETSQ.FT. SQUARE FOOT/FEETSHT. SHEETSHTHG. SHEATHINGSHLV. SHELF/SHELVESSIM. SIMILARSK. SINK or SKETCHS.M. SHEET METALS.M.D. SEE MECHANICAL DRAWINGSS.M.S. SHEET METAL SCREWS.N.D. SANITARY NAPIKIN DISPOSALS.N.V. SANITARY NAPKIN VENDORS.O.V. SHUT OFF VALVES.P.D. SEE PLUMBING DRAWINGSSPECS. SPECIFICATIONSSQ. SQUARES.S. SERVICE SINK or STAINLESS STEELS.S.D. SEE STRUCTURAL DRAWINGSS.ST. STAINLESS STEELSTD. STANDARDSTL. STEELSTN. STAINSTOR. STORAGESTRUCT. STRUCTURALSUSP. SUSPENDEDT & B TOP AND BOTTOMT.B. TOWEL BARTEL. TELEPHONET & G TONGUE AND GROOVET.O. TOP OF T.O.S. TOP OF SLABT.O.W. TOP OF WALLT.P.D. TOILET PAPER DISPENSERTRD. TREADTYP. TYPICALU.L. UNDERWRITERS LABORATORYUNF. UNFINISHEDU.O.N. UNLESS OTHERWISE NOTEDUR. URINALV.C.P. VITREOUS CLAY PIPEV.C.T. VINYL COMPOSITION TILEVERT. VERTICALVEST. VESTIBULEV.G.D.F. VERTICAL GRAIN DOUGLAS FIRV.W.C. VINYL WALL COVERINGW/ WITHW.C. WATER CLOSETWD. WOODW.H. WATER HEATERWNSCT. WAINSCOTW.P. WATERPROOF or WORK POINTW.R. WASTE RECEPTACLE orWATER RESISTANTW.S. WEATHER STRIPPINGW.W.F. WELDED WIRE FABRICW.W.M. WOVEN WIRE MESHA. ALL ACCESSIBLE PARKING STALLS SHALL BE ADA COMPLIANT.B. CONTRACTOR TO FIELD VERIFY EXISTING TOW-AWAY SIGN AT THE PARKING ENTRANCE (S) DRIVE FOR COMPLIANCE, PROVIDE NEW AS REQ'D. SEE "AS.6" SHEETS FOR REFERENCE TO SITE SIGN DETAILS.C. THE ACCESSIBLE PARKING STALLS SHALL HAVE A MAXIMUM OF 2% PERMITTED SLOPE IN ANY DIRECTION.D. PATCH & REPAIR ALL AREA DAMAGED DUE TO ANY NEW CONSTRUCTION AS REQUIRED TO MATCH EXISTING OR BETTER.E. SEE "AS.6" SHEET FOR REFERENCES TO ALL SITE ADA DETAILS.F. ALL SITE CONDITIONS ARE EXISTING TO REMAIN, U.ON. SEE "AS.4" SHEETS FOR ADDITIONAL SITE INFORMATION.G. CONTRACTOR TO SUBMIT SHOP DRAWINGS & FINISH MATERIAL & SAMPLES TO ARCHITECT FOR REVIEW, PROVIDE MIN. 3'-0" X 3'-0" MOCK-UP SAMPLES OF ALL CONCRETE & PAINT FINISH, & ALL OTHER FINISH DEEMED NECESSARY FOR ARCHITECT REVIEW PRIOR TO PURCHASE / FABRICATION.A. EXISTING FIRE SPRINKLER SYSTEM TO REMAIN. PROTECT AND MAINTAIN DURING CONSTRUCTION. CONTRACTOR'S PRICING SHALL INCLUDE MODIFYING THE EXISTING FIRE SPRINKLER AND FIRE ALARM SYSTEMS AS REQUIRED FOR NEW PLAN LAYOUT AND CODE REVISIONS INCLUDING ADA. CONTRACTOR WILL BE RESPONSIBLE FOR THE DRAWINGS, SUBMITTAL, AND APPROVAL OF ANY FIRE SPRINKLER AND FIRE ALARM WORK AS A DEFERRED SUBMITTAL.B. ALL DOORS ADJACENT TO WALLS ARE GIVEN AS 4" FROM FACE OF JAMB TO FACE OF FINISH OR ADJACENT WALL, TYPICAL U.O.N.C. PRESERVE AND MAINTAIN EXISTING EXITS THROUGHOUT CONSTRUCTION.D. PATCH AND REPAIR ALL AREAS THAT ARE AFFECTED DURING CONSTRUCTION.E. CONTRACTOR'S PRICE SHALL INCLUDE PROVIDING 10% COVERAGE OF EACH TYPE OF CARPET TILE ON THE PROJECT FOR "ATTIC STOCK".F. THE GENERAL CONTRACTOR SHALL ESTABLISH THE LOCATION OF ALL NEW WALLS IN THE FIELD ON THE FLOOR, EITHER WITH CHALK LINES OR TAPE AS APPROPRIATE. THEN GENERAL CONTRACTOR SHALL ARRANGE A WALK OF THE ENTIRE PROJECT AREA WITH THE OWNER AND ARCHITECT TO CONFIRM THAT THE SIZE, SHAPE, AND PLACEMENT OF ALL ROOMS RECEIVES OWNER APPROVAL PRIOR TO FRAMING ANY NEW WALLS. IF THE OWNER REQUESTS ANY CHANGE, GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT BEFORE PROCEEDING WITH SUCH CHANGE.G. ALL EXISTING TO REMAIN AND NEW WALL SURFACES TO RECEIVE SMOOTH LEVEL 4 FINISH. H. ALL PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE, U.O.N. ALL CLEAR DIMENSIONS ARE NOT ADJUSTABLE WITHOUT ARCHITECTS APPROVAL. I. UPON COMPLETION OF PARTITION LAYOUT, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT FOR REVIEW AND VERIFICATION OF LAYOUT PRIOR TO PARTITION INSTALLATION.J. ALL GYP. BD. PARTITIONS SHALL BE TAPED AND SANDED SMOOTH TO A LEVEL 4 FINISH U.O.N. THE CONTRACTOR SHALL PATCH AND REPAIR SURFACES TO MATCH ADJACENT OR ADJOINING SURFACES WHEREVER REQUIRED. THESE SURFACES SHALL BE ALIGNED AND SANDED SMOOTH. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE AND TRUE, AND IN PROPER ALIGNMENT. K. VERIFY POSITIONS OF EXISTING COLUMNS TO BE LOCATED WITHIN NEW WALL CONSTRUCTION AND NOTIFY ARCHITECT OF DISCREPANCIES.L. MAINTAIN ALL EXISTING RATED CONSTRUCTION UNLESS OTHERWISE NOTED ON PLANS. PATCH AND REPAIR AS REQUIRED TO INSURE INTEGRITY OF EXISTING FIRE RATINGS.M. FINISH FACES SHALL ALIGN AT JUNCTION OF NEW AND EXISTING CONSTRUCTION U.O.N.N. CONTRACTOR SHALL PROVIDE MOISTURE RESISTANT GYP. BD. IN BATHROOMS AS NOTED. SHOWER AREAS EXPOSED TO GREATER CONCENTRATIONS OF MOISTURE TO RECEIVE TILE BACKER BOARD.O. (E) PARTITIONS/EXTERIOR WALLS PATCH/REPAIR GYP. BD. AS NECESSARY. (TAPE, MUD, SAND TO LEVEL 4 FINISH). PATCH AND SKIM BASE OF WALLS WHERE BASE IS REMOVED. PREPARE FOR (N) N.I.C. FINISHES.P. LIGHTING/SIGNAGE SHALL COMPLY WITH CBC SECTION 1011.Q. EXISTING EXTERIOR WALL WITH BRICK VENEER TO REMAIN, U.O.N. PATCH/REPAIR AS REQUIRED. ANY NEW BRICK INFILL OR PATCH MUST MATCH EXISTING VENEER THAT REMAINS. CONTRACTOR TO DETERMINE BEST METHOD FOR MATCH-SALVAGE OF EXISTING TO BE REMOVED FOR INSTALL OR USE OF NEW BRICK VENEER THAT HAS BEEN TREATED AS REQUIRED TO LOOK AGED AND MATCHES EXISTING. INFILED/PATCH AREAS SHALL NOT APPEAR DIFFERENT THAN EXISTING TO REMAIN AREAS. ADDITIONALLY ALL INFILL/PATCHED AREAS SHALL NOT SHOW A VERTICAL OR HORIZONTAL 'CUT' SEAM, EXISTING VENEER SHALL BE REMOVED AS REQUIRED ON A FULL BRICK/COURSE SO THAT THE INFILL APPEARS SEAMLESS.R. PENETRATIONS OF FIRE-RATED CONSTRUCTION TO COMPLY WITH DETAILS AS SHOWN ON A9.10, TYP.A. CONTRACTOR'S PRICE SHALL INCLUDE ANY COSTS THAT WILL BE INCURRED TO MEET ALL CONDITIONS AND REQUIREMENTS OF THE OWNER WITH RESPECT TO DEMOLITION, CONTROL OF NOISE, REFUSE, SCREENING FOR DUST, AND GENERAL DISRUPTION TO CONTINUING OCCUPANCY AND OPERATION OF THE BUILDING.B. ALL EXISTING FACILITIES TO REMAIN UNLESS OTHERWISE NOTED TO BE REMOVED AND/OR RELOCATED.C. THE DESIGN INTENT IS TO PRESERVE THE INTEGRITY OF THE EXISTING STRUCTURAL SYSTEM. IF PLYWOOD, CONCRETE, OR STRUCTURAL STEEL IS ENCOUNTERED DURING DEMOLITION, CONTRACTOR SHALL NOTIFY ARCHITECT AND/OR BUILDING OWNER PRIOR TO PROCEEDING.D. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR EXTENT OFMECHANICAL, PLUMBING AND ELECTRICAL DEMOLITION WORK.E. EXISTING FIRE SPRINKLER SYSTEM TO REMAIN. PROTECT AND MAINTAIN DURING CONSTRUCTION. CONTRACTOR'S PRICING SHALL INCLUDE MODIFYING THE EXISTING FIRE SPRINKLER AND FIRE ALARM SYSTEMS AS REQUIRED FOR NEW PLAN LAYOUT AND CODE REVISIONS INCLUDING ADAF. CONTRACTOR'S PRICE SHALL INCLUDE ANY COSTS THAT WILL BE INCURRED TO MEET ALL CONDITIONS AND REQUIREMENTS OF THE OWNER WITH RESPECT TO DEMOLITION, CONTROL OF NOISE, REFUSE, SCREENING FOR DUST, AND GENERAL DISRUPTION TO CONTINUING OCCUPANCY AND OPERATION OF THE BUILDING.G. ALL EXISTING UTILITIES TO REMAIN UNLESS OTHERWISE NOTED TO BE REMOVED.H. THE DESIGN INTENT IS TO PRESERVE THE INTEGRITY OF THE EXISTING STRUCTURAL SYSTEM. IF PLYWOOD, CONCRETE, OR STRUCTURAL STEEL IS ENCOUNTERED DURING DEMOLITION, CONTRACTOR SHALL NOTIFY ARCHITECT BEFORE PROCEEDING. ALL BEARING WALLS, SHEAR WALLS, BRACE FRAMES, STRUCTURAL COLUMNS AND BEAMS TO REMAIN, U.O.N.I. IN AREAS OF DEMOLITION REMOVE ALL SUSPENDED CEILING GRID, TILES, DIFFUSERS, RETURNS, LIGHTS, BRANCH HVAC DUCTS, SPEAKERS, NON REQUIRED DRAFT STOPS. ETC. U.O.N.J. REMOVE ALL EXISTING PARTITIONS, FURRING, EQUIPMENT, FIXTURES, FLOORING, ETC. DOWN TO THE BUILDING SHELL AS REQUIRED FOR THE NEW WORK U.O.N. PREPARE SURFACES FOR THE NEW WORK. K. REMOVE ALL ABANDONED ELECTRICAL AND LIGHT U.O.N.L. CAP AND IDENTIFY EXPOSED UTILITIES. CONTRACTOR'S WORK ASSOCIATED WITH DISCONNECTING, REMOVING AND CAPPING UTILITY SERVICES WITHIN AREAS OF DEMOLITION IS INCLUDED IN SCOPE OF WORK.M. REMOVE ALL EXISTING FLOOR FINISHES AND BASE, U.O.N. REMOVE ALL EXISTING CONDITIONS WHICH CAUSE RISES OR DEPRESSION IN FLOORING SURFACE SUCH AS FASTENERS, OUTLET CORES, MOUNDED COVER PLATES, RESILIENT FLOORING, CARPET, CARPET PAD, FLASH PATCH, CONCRETE FILL, PLYWOOD, ETC. TO ENSURE FLOOR IS SMOOTH AND LEVEL. PREPARE FOR NEW FINISHES.N. PATCH REMAINING PORTIONS OF WALLS AND FINISHED SURFACES AS REQUIRED FOR NEW FINISHES.O. MAINTAIN BUILDING SECURITY, ALL LIFE SAFETY/FIRE PROTECTION SYSTEMS AND EXIT PASSAGES AT ALL TIMES. (E) FIRE SPRINKLERS TO REMAIN. RETROFIT AS REQUIRED FOR NEW WORK.P. THE ARCHITECT HAS NO KNOWLEDGE OF AND SHALL NOT BE HELD LIABLE FOR ANY ASBESTOS OR OTHER HAZARDOUS MATERIALS DISCOVERED DURING CONSTRUCTION. THE CONTRACTOR SHALL ISOLATE THE AFFECTED AREA AND CONTACT THE OWNER FOR FURTHER INSTRUCTIONS BEFORE PROCEEDING.Q. GENERAL CONTRACTOR TO VERIFY EXISTING CONDITIONS AND REPORT AND DISCREPANCIES TO ARCHITECT BEFORE START OF DEMOLITION.R. ANY QUESTIONS REGARDING SCOPE OF DEMOLITION SHALL BE CLARIFIED WITH ARCHITECT PRIOR TO PROCEEDING WITH WORK.S. COORDINATE SELECTIVE DEMOLITION AND REPAIR OF EXISTING SURFACES AS REQUIRED FOR INSTALLATION OF ELECTRICAL AND COMMUNICATION CONDUITS AS REQUIRED.T. ALL EXISTING BUILDING RATINGS ASSUMED TO MEET BUILDING CODS STANDARDS. THE ARCHITECT CAN NOT BE HELD LIABLE FOR ANY DISCREPANCIES IN EXISTING CONSTRUCTION. U. EXISTING EXTERIOR WALL WITH BRICK VENEER TO REMAIN, U.O.N. PATCH/REPAIR AS REQUIRED. ANY NEW BRICK INFILL OR PATCH MUST MATCH EXISTING VENEER THAT REMAINS. CONTRACTOR TO DETERMINE BEST METHOD FOR MATCH-SALVAGE OF EXISTING TO BE REMOVED FOR INSTALL OR USE OF NEW BRICK VENEER THAT HAS BEEN TREATED AS REQUIRED TO LOOK AGED AND MATCHES EXISTING. INFILED/PATCH AREAS SHALL NOT APPEAR DIFFERENT THAN EXISTING TO REMAIN AREAS. ADDITIONALLY ALL INFILL/PATCHED AREAS SHALL NOT SHOW A VERTICAL OR HORIZONTAL 'CUT' SEAM, EXISTING VENEER SHALL BE REMOVED AS REQUIRED ON A FULL BRICK/COURSE SO THAT THE INFILL APEPARS SEAMLESS.A. GENERAL CONTRACTOR TO REVIEW WALL LAYOUT WITH ARCHITECT PRIOR TO STARTING CONSTRUCTION.B. ALL WALL DIMENSIONS TO FINISHED FACE U.O.N.C. CURTAIN WALL DIMENSIONS TO OUTSIDE FACE OF FRAME U.O.N.D. WINDOW DIMENSIONS TO OUTSIDE EDGE OF FRAME U.O.N.E. SEE WINDOW ELEVATIONS FOR WINDOW MULLION DIMENSIONS.F. DOOR FINISHED OPENING 5" FROM FINISHED SURFACE OF WALL TYP.G. RAILING DIMENSIONS TO CENTER OF RAILING U.O.N.H. ALIGN FINISHED FACE TO FINISHED FACE AS NOTED.A. CONTRACTOR TO PROVIDE ANY MISSING ESCUTCHEONS AT SPRINKLER HEADS.B. REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR MORE INFORMATION. C. ALL LIGHT FIXTURES AND HVAC REGISTERS SHALL BE LOCATED ON CEILING GRID U.O.N. ALL CEILING FIXTURES INCLUDING ALL DOWNLIGHTS & SPRINKLER HEADS SHALL BE CENTERED ON PANEL OR TILE, TYPICAL UNLESS OTHERWISE NOTED.D. NOTIFY ARCHITECT OF ANY CONFLICTS WITH THE SUSPENDED CEILING GRID SYSTEM, HVAC, OR SPRINKLER FIXTURES PRIOR TO INSTALLATION. ALL FIXTURE RELOCATION IS SUBJECT TO SGA APPROVAL. E. EMERGENCY LIGHTING SHALL BE PROVIDED PER 2016 CBC SEC. 1006. NO SURFACE MOUNTED EMERGENCY LIGHTING FIXTURES WILL BE ACCEPTED. PROVIDE LOW-LEVEL EXIT SIGNS AND PATHWAY MARKING, WHERE REQUIRED BY 2016 C.B.C. SEC. 1011.6 FOR "A" OCCUPANCIES.F. ALL CEILING FIXTURES AND WIRING FOR LIGHT FIXTURES, EXIT SIGNS, OR OTHER ELECTRICAL DEVICES SHALL BE U.L. APPROVED, THERMALLY PROTECTED, AND SHALL BE INSTALLED IN CONDUIT OR OTHER WIRING METHOD APPROVED BY THE BUILDING DEPARTMENT.G. ALL SWITCHES, THERMOSTATS, AND OTHER WALL-MOUNTED CONTROL DEVICES SHALL BE MOUNTED AT 48" ABOVE UNFINISHED FLOOR TO TOP OF BOX U.O.N. H. SUBMITTALS AND SHOP DRAWINGS FOR ALL LIGHT FIXTURES ARE REQUIRED FOR APPROVAL PRIOR TO PURCHASE OF MATERIALS/FIXTURES.I. THIS DRAWING IS FOR LAYOUT PURPOSES ONLY. ENGINEERING OF SWITCHING AND CIRCUITRY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND REGULATIONS FOR BUILDING LIFE SAFETY, EMERGENCY, EGRESS AND NIGHT LIGHTS. SEE ELECTRICAL NOTES.J. HORNS AND STROBES SHALL BE PROVIDED THROUGHOUT AREA OF WORK AS REQUIRED TO MEET TITLE 24 REQUIREMENTS. LAYOUT MUST BE SUBMITTED TO SGA FOR APPROVAL PRIOR TO INSTALLATION.K. LIGHT FIXTURES AND SWITCHING SHALL CONFORM TO TITLE 24 REQUIREMENTS. DOUBLE SWITCH EACH FIXTURE SEPARATELY, ADDITIONALLY, LIGHT FIXTURES IN AREA OF WORK WITHIN 15'-0" OF EXTERIOR GLASS SHALL BE DOUBLE SWITCHED SEPARATELY PER CODE REQUIREMENTS. PROVIDE A CONSISTENT LAMP COLOR TEMPERATURE THROUGHOUT THE SPACE. MATCH EXISTING BUILDING STANDARD LAMP U.O.N.L. REWORK EXISTING LIGHT FIXTURE SWITCH LOCATIONS, HVAC DIFFUSER LOCATIONS, FIRE SPRINKLER LAYOUT AND THERMOSTAT LOCATIONS AS REQUIRED FOR NEW LOBBY LAYOUT. M. THE GENERAL CONTRACTOR SHALL FIELD-VERIFY EXISTING ROOF INSULATION, AND PROVIDE AN ALLOWANCE TO REPLACE MISSING OR DEFICIENT AREAS AS REQUIRED BY THE BUILDING DEPARTMENT.N. PATCH AND REPAIR ALL AREAS THAT ARE AFFECTED DURING CONSTRUCTION.O. ALL NEW GYP. BD. CEILINGS & SOFFITS SHALL BE SMOOTH FINISH, MATCH LEVEL OF EXISTING. EXISITNG SOFFITS TO REAMIN SHALL BE FINISHES TO SMOOTH LEVEL 4 AS WELL.P. ALL NEW EXTERIOR LIGHTS SHALL BE DAMP LABEL TYPE, TYPICAL.Q. EXIT SIGNS ARE NORMALLY ILLUMINATED AT ALL TIMES AND PROVIDED WITH AN EMERGENCY ELECTRICAL SYSTEM FROM STORAGE BATTERIES, UNIT EQUIPMENT, OR AN ON-SITE GENERATOR SET TO INSURE CONTINUED ILLUMINATION FOR AT LEAST 90 MINUTES IN CASE OF PRIMARY POWER LOSS.R. PROVIDE CEILING ACCESS PANELS AS REQUIRED FOR CODE COMPLIANCY AND MAINTENANCE OF ALL SYSTEMS ABOVE CEILING. CONTRACTOR TO ATTEMPT TO PROVIDE MULTIPLE POINTS OF ACCESS THROUGH ONE PANEL WHEN LAYOING OUT UTILITIES ABOVE CEILING. PRIOR TO INSTLLATION, CONTRACTOR TO REVIEW IN FIELD WITH ARCHITECT AND OWNER THE LOCATIONS OF ALL PANELS. CEILING ACCESS PANELS TO BE PAINTED TO MATCH CEILING FINISH.S. ALL LIGHTS & CEILING MOUNTED DEVICES SHALL BE CENTERED WITHIN VISUAL SIZE OF CEILING TILE, OR 1/2 OF TILE SIZE, U.O.N.T. OPEN TO STRUCTURE CEILING SHALL BE CLEANED OF DEBRIS, CAP ALL UNUSED CONDUIT, WIRE, PIPE & DUCT AND PREP TO RECEIVE NEW PAINT FINISH.A. IN AREAS OF DEMOLITION REMOVE ALL SUSPENDED CEILING GRID, TILES, DIFFUSERS, RETURNS, LIGHTS, BRANCH HVAC DUCTS, SPEAKERS, NON REQUIRED DRAFT STOPS. ETC. U.O.N.B. REFER TO DEMOLITION FLOOR PLAN FOR ADDITIONAL SCOPE OF LIMITED DEMOLITION WORK REQUIRED.C. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR MORE INFORMATION. A. ALL FINISHES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.B. ALL PAINTED SURFACES SHALL RECEIVE (2) COATS OVER PRIMER, TYPICAL UNLESS NOTED OTHERWISE.C. ALL AREAS TO RECEIVE PATCH & REPAIR SHALL MATCH ADJACENT FINISHES, TYPICAL UNLESS OTHERWISE NOTED.D. ALL FLOORING SHALL CONTINUE UNDER TOEKICKS AND COUNTERTOP OVERHANGS OF ALL CASEWORK, TYPICAL THROUGHOUT.E. CONTRACTOR SHALL PROVIDE (3) 4'x4' WALL SAMPLE BRUSH-OUTS OF PAINT COLOR FOR ARCHITECT'S AND TENANT'S REVIEW PRIOR TO PURCHASE OF PAINT. ASSUME (2) ROUNDS OF REVISIONS TO COLOR.F. ALL EXISTING PAINTED SURFACES SHALL RECEIVE NEW PAINT, U.O.N.G. FINISHES SHOWN IN ELEVATION -ASSUME WRAP BACK TO NEXT PARTNER SURFACE. REVIEW ALL TRANSITIONS WITH ARCHITECT. H. ALL FINISH MATERIALS, PAINTS, AND CARPETS TO COMPLY WITH CURRENT CALGREEN.I. PROVIDE 10% OVERAGE OF ALL FINISHES FOR TENANT.J. ALL WALLS SHALL BE MIN LEVEL 4 SMOOTH FINISH & PAINT P1, U.O.N. PROTECT ALL (E) FLOOR FINISHES TO REMAIN WITH MASONITE DURING CONSTRUCTION.K. FINISH MATERIAL POLLUTANT CONTROL: FINISH MATERIALS SHALL COMPLY WITH SECTIONS 5.504.4.1 THROUGH 5.504.4.4L. ADHESIVES, SEALANTS & CAULKS: ADHESIVES, SEALANTS & CAULKS USED ON THE PROJECT SHALL MEET THE REQUIREMENTS OF THE STANDARDS LISTED IN CGC 5.504.4.1M. PAINTS AND COATING: ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH TABLE 5.504.4.3 UNLESS MORE STRINGENT LOCAL LIMITS APPLY. VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AT THE REQUEST OF THE ENFORCING AGENCY.N. CARPET SYSTEMS: ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE TESTING & PRODUCT REQUIREMENTS OF ONE OF THE STANDARDS LISTED IN SECTION 5.504.4.4.O. COMPOSITE WOOD PRODUCTS: HARDWOOD, PLYWOOD, PARTICLEBOARD & MEDIUM DENSITY FIBERBOARD COMPOSITE WOOD PRODUCTS USED ON THE INTERIOR OR EXTERIOR OF THE BUILDING SHALL MEET THE REQUIREMENTS FOR FORMALDEHYDE AS SPECIFIED IN TABLE 5.504.4.5.A. PROVIDE CEILING ACCESS PANELS AS REQUIRED FOR CODE COMPLIANCY AND MAINTENANCE OF ALL SYSTEMS ABOVE CEILING. CONTRACTOR TO ATTEMPT TO PROVIDE MULTIPLE POINTS OF ACCESS THROUGH ONE PANEL WHEN LAYING OUT UTILITIES ABOVE CEILING. PRIOR TO INSTALLATION, CONTRACTOR TO REVIEW IN FIELD WITH ARCHITECT AND OWNER THE LOCATIONS OF ALL PANELS. CEILING ACCESS PANELS TO BE PAINTED TO MATCH CEILING FINISH.B. PROVIDE WALL ACCESS PANELS AS REQUIRED FOR CODE COMPLIANCE AND MAINTENANCE OF ALL SYSTEMS IN WALLS. CONTRACTOR TO LIMIT THE NUMBER OF PANELS. LOCATION TO BE UNDER SINK AND WITHIN TOILET PARTITION AREAS. PRIOR TO INSTALLATION, CONTRACTOR TO REVIEW IN FIELD WITH ARCHITECT AND OWNER THE LOCATIONS OF ALL PANELS. WALL PANELS ARE TO BE #4 BRUSHED STAINLESS STEEL.C. COORDINATE CEILING MECHANICAL VENT LOCATIONS WITH MECHANICAL DRAWINGS. PRIOR TO INSTALLATION, LOCATIONS ARE TO BE REVIEWED IN FIELD WITH ARCHITECT AND OWNER.D. ALL WALLS SHALL BE PREPPED FOR LEVEL 4 SMOOTH FINISH AND RECEIVE NEW PAINT, P1 U.O.N.A. PROVIDE HARDWARE SUBMITTAL FOR ARCHITECT'S REVIEW BEFORE ORDERING HARDWARE.B. ALL DOOR HARDWARE MUST COMPLY WITH 2016 CALIFORNIA BUILDING CODE SECTION 1008.1.9C. ALL DOOR HARDWARE SHALL BE US26D SATIN CHROMIUM PLATED, ND-SERIES, SPARTA LEVER, AND ALL SEALS SHALL BE BLACK, UNLESS OTHERWISE NOTED.D. ALL CYLINDERS SHALL BE MASTER KEYED AND KEYED DIFFERENTLY U.N.O. IN WRITING BY THE OWNER PRIOR TO SHIPMENT OF HARDWARE TO JOB SITE.E. (2) COPIES OF EACH KEY SHALL BE SUPPLIED TO OWNER. NO OTHER COPIES SHALL EXIST WITHOUT OWNER'S CONSENT.F. MAXIMUM FORCE REQUIRED TO OPERATE ALL FIRE-RATED DOORS (CORRIDORS, OCCUPANCY SEPARATIONS, STAIRWAY ENCLOSURES, ETC.) SHALL BE 15 POUNDS.G. MAXIMUM FORCE REQUIRED TO OPERATE ALL EXTERIOR & INTERIOR DOORS SHALL BE 5 POUNDS.H. ALL GLAZING SUBJECT TO HUMAN IMPACT AND WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF ANY DOOR IN A CLOSED POSITION SHALL BE SAFETY GLAZING.I. FLOOR OR LANDING AT EACH DOOR SHALL NOT BE MORE THAN 1/2" LOWER THAN THE THRESHOLD.J. LANDINGS AT ALL DOORS SHALL COMPLY WITH 2016 CALIFORNIA BUILDING CODE SECTION 1008.1.6K. ALL DOORS SHALL BE EQUIPPED WITH SINGLE EFFORT, NON-GRASP LEVER HARDWARE INSTALLED MINIMUM 30" AND MAXIMUM 44" ON CENTER ABOVE FINISHED FLOOR IN CONFORMANCE WITH 2016 CALIFORNIA BUILDING CODE SECTION 1133B.2.5.2.L. ALL FIRE-RATED EXIT ACCESS DOORS SHALL BEAR AN APPROVED LABEL OR OTHER IDENTIFICATION SHOWING THE RATING THERE OF, THE NAME OF THE MANUFACTURER, AND THE IDENTIFICATION OF THE SERVICE CONDUCTING THE INSPECTION OF MATERIALS AND WORKMANSHIP AT THE FACTORY DURING FABRICATION AND ASSEMBLY AS REQUIRED UNDER 2016 CALIFORNIA BUILDING CODE SECTION 715.4M. ALL DOORS WITH CARD READERS AND ELECTRICAL TRANSFER HINGES SHALL BE FACTORY BORED.N. ALL TOP & BOTTOM DOOR BOLT STRIKE CUPS SHALL BE FINISH US26D.O. ALL DOOR STRIKES SHALL BE PROVIDED WITH DUST BOXES. DUST BOXES SHALL MATCH DOOR HARDWARE FINISH, BRASS IS NOTPERMITTED.P. ELECTRIC CARD KEY ACCESS IS ONLY USED FOR ENTERING INTO SPACES WITH RESTRICTED ACCESS. ELECTRIC CARD KEYS ARE NEVER REQUIRED TO EXIT OUT OF ANY AREA OR OUT OF THE BUILDING.Q. ALL EXIT DOORS SHALL OPEN FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT.R. FOLDING EXTERIOR WALL, HARDWARE TO BE SPECIFIED AND PROVIDED BY MANUFACTUREER. FINISH TO MATCH BRUSHED S.S. S. ALL HARDWARE TO BE SPECIFIED AND PROVIDED BY MANUFACTURER. FINISH TO MATCH BRUSHED S.S.T. ALL EXTERIOR DOORS & HARDWARE SYSTEMSSHALL CONFORM TO TITLE 24 REQUIREMENTS.SECTION REFERENCE NO.COLUMN OR GRIDLINEAAX.XXREVISION NUMBER -SEE REVISION INFO & DATE ON COVER SHEET AND/OR TITLE BLOCKOFFICE103# SFSECTION REFERENCE SHEET NO.ELEVATION REFERENCE NO. (EXTERIOR)ELEVATION REFERENCE SHEET NO. (EXTERIOR)DETAIL REFERENCE NO.DETAIL REFERENCE SHEET NO.1DATUM / POINT OF REFERENCEINTERIOR ELEVATION REFERENCE NO.ELEVATION REFERENCE SHEET NO.DABCKEYNOTE REFERENCEROOM NAMEROOM NUMBERCEILING HEIGHTWINDOW TAG101DOOR TAG8'-8 1/2"1/A2.1AELEVATION VIEW NUMBER & SHEET (INTERIOR)DIRECTION OF ELEVATION VIEW (INTERIOR)TYPAX.XXOPPHANDAX.XXREVISION CLOUDAX.XX?XROOM AREAATYPTYPB2WALL TAGSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250SAN JOSE, CA 95110T:408.283.0100 ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTEN MATERIALS INDICATED HEREIN ARE THE WORK AND PROPERTY OF STUDIO G ARCHITECTS. THIS DOCUMENT MAY NOT BE DUPLICATED, REUSED OR DISCLOSED BY ANY METHOD WITHOUT THE WRITTEN CONSENT OF STUDIO G ARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESS1/4" = 1'-0"12/14/2020 8:30:03 PMA0.1GENERAL NOTES,ABBREVIATIONS & LEGENDSPOOL DECK IMPROVEMENTS forKL08/06/20202017.15019608 Pruneridge AveCupertino, CA 95014ABBREVIATIONSGENERAL NOTES1. THESE GENERAL NOTES SHALL APPLY TO ALL WORK AND ALL DRAWINGS IN THIS SET AND SHALL EXTEND TO ANY CHANGES, EXTRAS, OR ADDITIONS AGREED TO DURING THE COURSE OF THE WORK.2. BIDDERS ARE INSTRUCTED TO VISIT AND INSPECT THE PREMISES PRIOR TO SUBMITTING THEIR PROPOSALS, AND TO FAMILIARIZE THEMSELVES WITH THE CONDITIONS UNDER WHICH THE WORK WILL BE PERFORMED. NO SUBSEQUENT EXTRAS OR ADDITIONS WILL BE ALLOWED ON ANY CLAIM FOR LACK OF KNOWLEDGE OF CONDITIONS OR CIRCUMSTANCES ABOUT WHICH THE BIDDER COULD HAVE INFORMED HIMSELF. APPOINTMENTS SHALL BE ARRANGED THROUGH THE OWNER'S REPRESENTATIVE.3. BIDDERS SHALL MAKE KNOWN TO THE ARCHITECT ANY LIMITATIONS, EXCLUSIONS, OR MODIFICATIONS TO THE PROJECT DURING BIDDING PHASE OF THE PROJECT. UNLESS SPECIFICALLY NOTED THEY WILL BE PRESUMED TO BE INCLUDED IN THE BID. NO SUBSEQUENT EXTRAS OF ADDITIONS WILL BE ALLOWED FOR LIMITATION, EXCLUSIONS OR MODIFICATIONS NOT NOTED BY BIDDER.4. THE GENERAL CONTRACTOR SHALL PAY ALL FEES AND SECURE ALL REQUIRED PERMITS FOR THE WORK INDICATED ON THE DRAWINGS.5. THE GENERAL CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE PREMISES ON WHICH THE WORK IS PERFORMED, AS WELL AS FOR SAFETY OF ALL PERSONS AND PROPERTY ON THE SITE DURING PERFORMANCE OF HIS/HER CONTRACT. THESE REQUIREMENTS SHALL NOT BE LIMITED TO NORMAL WORKING HOURS, BUT SHALL APPLY CONTINUOUSLY ALL HOURS OF THE DAY (24 HOURS) AND ALL CALENDAR DAYS OF THE WEEK (7 DAYS).6. THERE SHALL BE NO SUBSTITUTION OF MATERIALS WHERE A MANUFACTURER IS SPECIFIED. WHERE THE TERM "OR APPROVED EQUAL" IS USED, THE ARCHITECT AND OWNER SHALL DETERMINE THE EQUALITY BASED UPON THE INFORMATION SUBMITTED BY THE CONTRACTOR. INFORMATION MUST BE PROVIDED FROM A MANUFACTURER AND MUST INCLUDE A SIDE-BY-SIDE COMPARISON OF EACH PRODUCT IDENTIFYING THE CRITICAL COMPONENTS FOR COMPARISON (STRUCTURAL, SYSTEM COMPONENTS AND DETAILS, FIRE/LIFE/SAFETY, COLOR OPTIONS, MATERIALS, LEED, WARRANTY, ETC.). 7. THE GENERAL CONTRACTOR SHALL REVIEW ALL PLANS AND SPECIFICATIONS, AND VERIFY ALL GOVERNING DIMENSIONS AT THE BUILDING PRIOR TO THE COMMENCEMENT OF THE WORK. HE/SHE SHALL EXAMINE ALL ADJOINING WORK AND/OR AREAS UPON WHICH THE PERFORMANCE OF THEIR WORK IS IN ANY WAY DEPENDENT. ANY VARIATIONS OR DISCREPANCIES SHALL BE REPORTED WITH ALL DUE EXPEDIENCY TO THE ARCHITECT AND OWNER PRIOR TO THE FABRICATION OR ERECTION OF THE WORK IN QUESTION.8. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISTRIBUTION OF DRAWINGS TO ALL TRADES UNDER HIS JURISDICTION. AFTER EXECUTION OF THE CONSTRUCTION CONTRACT, THE AWARDED GENERAL CONTRACTOR WILL RECEIVE ONE COMPLETE SET OF DOCUMENTS AS "ISSUED FOR CONSTRUCTION".9. ANY INFORMATION REQUIRED BY THE CONTRACTORS THAT IS NOT SHOWN ON THE DRAWINGS, SPECIFICATIONS, OR OTHER DOCUMENTS SHALL BE REQUESTED BY THE GENERAL CONTRACTOR FROM THE ARCHITECT PRIOR TO BID OR PRIOR TO COMMENCEMENT OF WORK.10. NO PORTION OF WORK REQUIRING A SHOP DRAWING OR SAMPLE REVIEW SHALL COMMENCE PRIOR TO SUBMITTAL BY CONTRACTOR AND REVIEW AND APPROVAL BY OWNER AND ARCHITECT.11. SHOULD THE GENERAL CONTRACTOR BY THEIR OWN FAULT FAIL TO ADHERE TO THE CONSTRUCTION SCHEDULE, HE/SHE SHALL (AT THE DISCRETION OF THE OWNER) PERFORM WORK ON PREMIUM TIME TO CONFORM WITH THE SCHEDULE. ANY EXPENSES ATTRIBUTED TO SUCH WORK SHALL BE BORNE BY THE GENERAL CONTRACTOR. IN ADDITION, AT THE TIME OF FAILURE TO CONFORM TO THE CONSTRUCTION SCHEDULE, THE GENERAL CONTRACTOR SHALL SUBMIT A RECOVERY SCHEDULE FOR REVIEW AND APPROVAL BY THE OWNER, INDICATING MILESTONES AND COMPLETION DATES.12. THE GENERAL CONTRACTOR SHALL SUPPLY A LIST OF ALL SUBCONTRACTORS TO THE ARCHITECT AND OWNER PRIOR TO COMMENCEMENT OF WORK. INFORMATION SHALL INCLUDE THE NAME OF THE PRINCIPLE CONTACT, THE COMPLETE ADDRESS (PHYSICAL BUSINESS AND MAILING), THE TELEPHONE NUMBER, AND THE EMAIL ADDRESS FOR EACH SUBCONTRACTOR RESPONSIBLE FOR ANY PORTION OF THE WORK.13. THE GENERAL CONTRACTOR SHALL, COMPLY WITH THE RULES AND REGULATIONS OF THE CITY, INCLUDING THE HOURS OF AVAILABILITY, MANNER OF HANDLING MATERIALS, DELIVERIES, EQUIPMENT, AND DEBRIS TO AVOID CONFLICT AND INTERFERENCE WITH NORMAL OPERATIONS.14. ALL DIMENSIONS SHOWN ARE TAKEN TO FACE OF FINISH U.O.N. 15. WEEKLY REPORT FORM, SIGNED BY THE GENERAL CONTRACTOR OR SUPERINTENDENT SHALL BE COMPLETED AND DELIVERED TO THE ARCHITECT AND OWNER. THIS REPORT SHALL INDICATED WORK IN PROGRESS AND ITEMS TO BE RESOLVED, AS WELL AS CRITICAL MILESTONES.16. THE GENERAL CONTRACTOR SHALL BE ANSWERABLE TO THE OWNER'S REPRESENTATIVE FOR HIS/HER WORK AND SHALL NOT ACCEPT INSTRUCTION FROM OTHER PERSONNEL WITHOUT VERIFICATION FROM THE OWNER. CONTRACTOR SHALL BE LIABLE FOR ANY EXPENSE CAUSED BY EXECUTION OF WORK WITHOUT SUCH VERIFICATION AND FOR THE EXPENSE CAUSED BY REMOVAL AND CORRECTION OF SUCH WORK.17. A REPRESENTATIVE OF THE GENERAL CONTRACTOR AUTHORIZED TO DISCUSS THE WORK AND RECEIVE INSTRUCTIONS FROM THE ARCHITECT SHALL BE AVAILABLE AT ALL TIMES WHILE THE WORK IS IN PROGRESS.18. GREAT CARE SHALL BE EXERCISED TO ASSURE THAT THE BUILDING SHALL BE PROTECTED FROM DAMAGE THAT COULD OCCUR BECAUSE OF THIS WORK AND THE CONTRACTOR SHALL PROVIDE PROTECTION FOR EXISTING AREAS AND NEW WORK AREAS. ANY DAMAGE DUE TO WORK OR ACCIDENTS, SHALL BE REPAIRED, REPLACED, OR PATCHED AT THE DISCRETION OF THE OWNER. THE CONTRACTOR SHALL BEAR ALL FINANCIAL RESPONSIBILITY FOR DAMAGE AND SUBSEQUENT REPAIRS DUE TO FAILURE OF PROTECTING EXISTING AREAS AND NEW WORK AND/OR ACCIDENTS.19. THE CONTRACTOR SHALL PROTECT ALL MATERIALS THAT EXIST ON THE JOB SITE FROM DAMAGE AND SHALL MAINTAIN PROTECTION DURING THE EXECUTION OF THE WORK. THIS PROTECTION EXTENDS OUTSIDE OF THE BUILDING TO ALL LOCATIONS ON THE SITE INCLUDING ANY AREAS USED FOR ROUTING MATERIALS TO AREAS OF WORK. THE CONTRACTOR IS RESPONSIBLE TO RECTIFY ANY DAMAGE ATTRIBUTABLE TO HIS/HER OPERATIONS FOR THE DURATION OF WORK AND CONTRACT TIME.20. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL WOODWORK, DOORS & FRAMES, WINDOWS, AND ALL WORK AS MAY BE SPECIFICALLY REQUESTED IN THE CONTRACT DOCUMENTS TO THE ARCHITECT FOR REVIEW AND WRITTEN APPROVAL. SHOP DRAWINGS SHALL SHOW ALL DIMENSIONS AND CONDITIONS, INCLUDING VERIFICATIONS FROM IN-FIELD AS NECESSARY. WHEN THE ARCHITECT REQUIRES A REVISION AND RESUBMITTAL OF THE SHOP DRAWINGS, SUCH RESUBMITTALS SHALL OCCUR WITHIN ONE (1) WEEK OF NOTIFICATION OF SUCH REQUIREMENT AND SHALL NOT BE SUBJECT TO ADDITIONAL COST TO THE OWNER.21. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE EXTENT, NATURE AND SCOPE OF WORK DESCRIBED IN THE CONTRACT DOCUMENTS AND COORDINATE WITH THE OWNER AND ARCHITECT THE INTERFACING OF ANY OWNER WORK WITH THAT INDICATED IN THE CONTRACT DOCUMENTS. THE GENERAL CONTRACTOR IS TO PROVIDE ALL LABOR AND MATERIALS NECESSARY TO EXECUTE ALL WORK AS SHOWN/INDICATED IN DRAWINGS, SPECIFICATIONS, AND DOCUMENTS, WITH THE EXCEPTION OF THOSE ITEMS AS NOTED AS "N.I.C." OR AS NOTED TO BE SEPARATE CONTRACTS. HE/SHE SHALL BE RESPONSIBLE FOR COORDINATING THE WORK WITH THAT OF ALL OTHER TRADES, INCLUDING COORDINATION WITH THOSE TRADES OPERATING UNDER SEPARATE CONTRACTS WITH THE OWNER.22. ALL WORK SHALL BE PERFORMED BY SKILLED AND QUALIFIED WORKMEN AND IN ACCORDANCE WITH THE HIGHEST STANDARD OF QUALITY AND BEST PRACTICES OF THE TRADES INVOLVED. CARE SHALL BE TAKEN TO ENSURE COMPLIANCE WITH BUILDING REGULATIONS/CODES, AND/OR GOVERNMENTAL LAWS, STATUES OF ORDINANCES CONCERNING THE USE OF LABOR, AND CONDUCTED IN THE MANNER OF INDUSTRY STANDARD PRACTICE.23. ALL MATERIALS TO BE NEW, UNUSED AND OF THE HIGHEST QUALITY IN EVERY RESPECT UNLESS OTHERWISE NOTED.24. ALL WORK SHALL BE INSTALLED AND ERECTED PLUMB, LEVEL, SQUARE AND TRUE, IN PROPER ALIGNMENT.25. MANUFACTURED MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS UNLESS OTHERWISE NOTED.26. WORK IS TO BE PERFORMED IN ACCORDANCE WITH THE RULES AND REGULATIONS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION AND SHALL CONFORM WITH ALL CITY, COUNTY, STATE AND FEDERAL CONSTRUCTION SAFETY AND SANITARY LAWS, CODES, STATUTES AND ORDINANCES. ANY DISCREPANCIES, VARIATIONS OR OMISSIONS IN THE CONTRACT DOCUMENTS SHALL BE REPORTED PROMPTLY TO THE OWNER AND ARCHITECT.27. TIME IS OF THE ESSENCE AND THE GENERAL CONTRACTOR SHALL KEEP SUFFICIENT WORKMEN ON THE JOB SITE AT ALL TIMES TO PERFORM THE WORK PER THE SCHEDULE AND IN THE MOST EXPEDITIOUS MANNER CONSISTENT WITH GOOD WORKMANSHIP, SOUND BUSINESS PRACTICES, AND IN THE BEST INTERESTS OF THE OWNER.28. IT IS EXPECTED THAT SUFFICIENT LABOR WILL BE PROVIDED SO THATACTIVITY FOR ANY GIVEN TRADE WILL NOT BE LIMITED TO ONLY ONE PART OF THE TOTAL WORK AREA.29. EACH TRADE WILL BE EXPECTED TO PROCEED IN A FASHION THAT WILL NOT DELAY OR DETAIN THE TRADE FOLLOWING THEM.30. ALL WORK SHALL BE COMPLETED FOR THE AGREED CONTRACT PRICE WITHOUT RECOURSE TO LABOR STOPPAGES OR REVISIONS OF GOVERNING REGULATIONS, LAWS, AND CODES ABOUT WHICH THE CONTRACTOR COULD HAVE REASONABLY BEEN EXPECTED TO HAVE ANY FOREWARNING AND TO HAVE MADE APPROPRIATE CONTINGENCY PLANS PRIOR TO THE EXECUTION OF THE CONTRACT.31. THE CONTRACTOR SHALL NOT PROCEED WITH ANY ADDITIONAL WORK OR CHANGES FOR WHICH EXPECTS ADDITIONAL COMPENSATION BEYOND THE CONTRACT AMOUNT WITHOUT WRITTEN AUTHORIZATION FROM THE OWNER. FAILURE TO OBTAIN SUCH AUTHORIZATION SHALL INVALIDATE ANY CLAIM FOR EXTRA COMPENSATION AND WORK WILL BE CONSIDERED NON-CONFORMING.32. DO NOT SCALE DRAWINGS, DIMENSIONS SHALL GOVERN. DETAILS SHALL GOVERN OVER PLANS AND ELEVATIONS. LARGE SCALE DETAILS SHALL GOVERN OVER SMALL SCALE DETAILS. CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO THE OWNER AND ARCHITECT PRIOR TO COMMENCEMENT OF WORK.33. CUTTING, CHASING, DRILLING OR DEMOLITION OF WALLS, SLABS, ETC. REQUIRING THE USE OF JACK HAMMERS OR OTHER HEAVY HAND OR POWER TOOLS SHALL BE PERFORMED PER CITY REQUIREMENTS. THIS PROVISION EXTENDS TO ALL EQUIPMENT USED IN THE WORK.34. ALL INSTALLED PLUMBING, MECHANICAL, AND ELECTRICAL EQUIPMENT SHALL OPERATE QUIETLY AND BE FREE OF VIBRATIONS TO THE EXTENT POSSIBLE.35. ALL WORK AND MATERIALS SHALL BE GUARANTEED AGAINST DEFECTS IN DESIGN, WORKMANSHIP, AND MATERIALS FOR A PERIOD OF AT LEAST ONE (1) YEAR FROM APPROVAL FOR FINAL PAYMENT.36. CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES FREE OF ACCUMULATIONS OF WASTE MATERIALS OR RUBBISH CAUSED BY THEIR OPERATIONS OR OPERATIONS OF SEPARATE CONTRACTORS. CONTRACTOR SHALL CONFINE THEIR OPERATIONS FOR REMOVAL TO SUCH METHODS AS MAY BE AGREEABLE TO THE OWNER. THE PROJECT SHALL BE LEFT CLEAN AND CLEAR TO THE SATISFACTION OF THE OWNER AND THE DISPOSITION TO ALL SALVAGED MATERIALS TO BE CLEARED WITH THE OWNER PRIOR TO REMOVAL. PREMISES TO BE SWEPT CLEAN OF RELATED CONSTRUCTION DEBRIS DAILY.37. UPON COMPLETION OF THE WORK THE CONTRACTOR SHALL NOTIFY THE ARCHITECT. THE ARCHITECT SHALL REVIEW THE WORK AND COMPILE A "PUNCH LIST" OF NEEDED CORRECTIONS AND UNSATISFACTORY AND/OR INCOMPLETE WORK. FINAL PAYMENT WILL BE CONTINGENT ON THE COMPLETION OF THESE ITEMS UNDER THE TERMS OF THE CONTRACT.38. THE MAXIMUM FLAME SPREAD CLASSIFICATION OF FINISH MATERIALS USED ON WALLS AND CEILINGS MUST COMPLY WITH 2016 CBC CHAPTER 8, AS WELL AS ALL CODE REQUIREMENT FOR FIRE RATING.39. DRAWINGS IN THIS SET AND THE DESIGNS THEREON ARE THE PROPERTY OF STUDIO G ARCHITECTS, INC. AND SHALL NOT BE REPRODUCED IN ANY WAY WITHOUT SPECIFIC WRITTEN AUTHORIZATION FROM STUDIO:G ARCHITECTS, INC.40. IT IS INTENDED THAT THE GENERAL CONTRACTOR WILL PROVIDE A COMPLETE JOB AND ANY OMISSIONS IN THESE NOTES OR IN THE OUTLINE OF THE WORK SHALL NOT BE CONSTRUED AS RELIEVING THE GENERAL CONTRACTOR OF SUCH RESPONSIBILITIES AS ARE IMPLIED BY THE SCOPE OF WORK, EXCEPT ITEMS SPECIFICALLY NOTED.41. ELECTRICAL CONTRACTORS SHALL FURNISH AND INSTALL ALL FIXTURES, LAMPS AND ACCESSORIES AS INDICATED ON THE DRAWINGS. DESIGN INTENT IS THAT ALL FIXTURES ARE TO BE COMPLETE WITH LAMPS AND ACCESSORIES FOR FULLY FUNCTIONAL ELECTRICAL SYSTEMS. SUBSTITUTIONS WILL NOT BE ALLOWED WITHOUT WRITTEN AUTHORIZATION FROM THE OWNER.42. HEATING, VENTILATING, AND AIR CONDITIONING: ALL WORK SHALL CONSIST OF ALL LABOR, MATERIALS AND SERVICES REQUIRED FOR MODIFICATIONS TO THE EXISTING SYSTEMS, AND SHALL RESULT IN A COMPLETE OPERABLE FORCED AIR HEATING, VENTILATING AND AIR CONDITIONING SYSTEM, IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES, REQUIREMENTS OF THE SERVICING UTILITY AND FUNCTIONS SHOWN ON THE DRAWINGS.43. ELECTRICAL: ALL WORK SHALL CONSIST OF ALL LABOR, MATERIALS AND SERVICES REQUIRED FOR MODIFICATIONS TO THE EXISTING SYSTEMS, AND SHALL RESULT IN A COMPLETE WIRING SYSTEM INCLUDING, BUT NOT LIMITED TO, OUTLETS, WALL SWITCHES, AND INSTALLATION OF LIGHTING FIXTURES, LAMPS, APPLIANCES, AND LIKE ACCESSORIES AS INDICATED ON THE DRAWINGS OR AS REQUIRED FOR THE COMPLETION OF THE WORK.44. PLUMBING: ALL WORK SHALL CONSIST OF ALL LABOR, MATERIALS AND SERVICES REQUIRED FOR MODIFICATIONS TO THE EXISTING SYSTEMS, AND SHALL RESULT IN A COMPLETE SYSTEM INCLUDING, BUT NOT LIMITED TO, DRAIN-WASTE AND VENT LINES, HOT AND COLD WATER LINES, AND GAS LINES AS INDICATED ON THE DRAWINGS. ALL EXCAVATION, SAW CUTTING, AND BACKFILL IS REQUIRED AND CONSIDERED PART OF THE CONTRACTOR, AS IS THE INSTALLATION OF ALL FIXTURES AND APPLIANCES. THE SYSTEM SHALL MEET THE REQUIREMENTS OF THE STATE BOARD OF HEALTH AND ALL LOCAL CODES AND REGULATIONS.45. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL EXIT SIGNS AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION (LOCAL BUILDING CODES) AND SHALL SUBMIT THOSE SIGNS (LOCATE SIGNS ON PLAN AND PROVIDE CUT SHEETS FOR STYLES) TO THE OWNER AND ARCHITECT FOR REVIEW AND APPROVAL.46. THE GENERAL CONTRACTOR SHALL ESTABLISH THE LOCATION OF ALL NEW WALLS IN THE FIELD ON THE FLOOR, EITHER WITH CHALK LINES OR TAPE, AS APPROPRIATE. THE GENERAL CONTRACTOR SHALL ARRANGE A WALK OF THE ENTIRE PROJECT AREAS WITH THE OWNER/TENANT AND ARCHITECT TO CONFIRM THE SIZE, SHAPE, AND PLACEMENT OF ALL ROOMS TO OBTAIN OWNER/TENANT APPROVAL PRIOR TO EXECUTION OF FRAMING ANY NEW WALLS. IF THE OWNER/TENANT REQUESTS ANY CHANGE, THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT BEFORE PROCEEDING WITH ANY CHANGE.47. FINISHES SHOWN IN ELEVATION SHALL BE ASSUMED TO WRAP ON ADJACENT SURFACE (WHICH MAY NOT NECESSARILY BE SHOWN IN ELEVATION). GENERAL CONTRACTOR SHALL WALK PROJECT WITH THE OWNER/TENANT AND ARCHITECT TO CONFIRM ALL START AND STOP POINTS OF FINISHES.FIRE PREVENTIONGENERAL RESTROOM PLAN NOTESGENERAL REFLECTED CEILING PLAN NOTES1. THIS PROJECT MAY REQUIRE MODIFICATIONS TO THE BUILDINGS FIRE SPRINKLER SYSTEM. PRIOR TO MAKING ANY CHANGES TO THE FIRE SPRINKLER SYSTEM, PROVIDE CONSTRUCTION DOCUMENTS TO THE COUNTY FIRE DEPARTMENT FOR REVIEW AND PERMIT ISSUANCE. THE COUNTY FIRE DEPARTMENT PROVIDES FIRE PREVENTION SERVICES TO THE CITY OF CUPERTINO AND HAS OFFICES LOCATED AT 20215 STEVENS CREEK BLVD, CUPERTINO.2. THIS PROJECT WILL REQUIRE A FIRE CODE CONSTRUCTION PERMIT. PRIOR TO INSTALLATION, PROVIDE APPROVED CONSTRUCTION DOCUMENTS AND A PERMIT APPLICATION TO THE COUNTY FIRE DEPARTMENT FOR REVIEW AND PERMIT ISSUANCE. THE COUNTY FIRE DEPARTMENT PROVIDES FIRE PREVENTION SERVICES TO THE CITY OF CUPERTINO AND HAS OFFICES LOCATED AT 20215 STEVENS CREEK BLVD., CUPERTINO.3. PROVIDE THE REQUIRED LABELING/MARKING & IDENTIFICATION OF ANY FIRE-BARRIERS, FIRE-PARTITIONS, SMOKE BARRIERS & SMOKE PARTITIONS AS REQUIRED PER 2016 CBC SECTION 703.7. WHEREAS, FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY & PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING, SUCH IDENTIFICATION SHALL:A. BE LOCATED IN ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING OR ATTIC SPACES;B. BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL & AT INTERVALS NOT EXCEEDING 30 FEET MEASURE HORIZONTALLY ALONG THE WALL OR PARTITION; &C. INCLUDE LETTERING NOT LESS THAN 3 INCHES IN HEIGHT WITH A MINIMUM 3/8 INCH STROKE IN A CONTRASTING COLOR INCORPORATING THE SUGGESTED WORDING. " FIRE AND/OR SMOKE BARRIER-PROTECT ALL OPENINGS" OR OTHER WORDING.SYMBOLS & LEGENDGENERAL CONSTRUCTION PLAN NOTESGENERAL DEMOLITION FLOOR PLAN NOTESGENERAL DIMENSION PLAN NOTESGENERAL SITE NOTESGENERAL RCP DEMOLITION NOTESGENERAL FINISHES NOTESGENERAL DOOR NOTESNO. DATE DESCRIPTION08/06/2020 PLANNING SET
SCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250SAN JOSE, CA 95110T:408.283.0100 ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTEN MATERIALS INDICATED HEREIN ARE THE WORK AND PROPERTY OF STUDIO G ARCHITECTS. THIS DOCUMENT MAY NOT BE DUPLICATED, REUSED OR DISCLOSED BY ANY METHOD WITHOUT THE WRITTEN CONSENT OF STUDIO G ARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSFOR REFERENCE ONLY1" = 40'-0"12/14/2020 8:25:59 PMAS.1EXISTING SITE PLAN (FORREFERENCE ONLY)POOL DECK IMPROVEMENTS forAUTHOR08/06/20202017.15019608 Pruneridge AveCupertino, CA 95014NO. DATE DESCRIPTION08/06/2020 PLANNING SET1" = 40'-0"1SITE PLAN - EXISTING (FOR REFERENCE ONLY)REF.NORTHTRUENORTH
SCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250SAN JOSE, CA 95110T:408.283.0100 ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTEN MATERIALS INDICATED HEREIN ARE THE WORK AND PROPERTY OF STUDIO G ARCHITECTS. THIS DOCUMENT MAY NOT BE DUPLICATED, REUSED OR DISCLOSED BY ANY METHOD WITHOUT THE WRITTEN CONSENT OF STUDIO G ARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSFOR REFERENCE ONLY1" = 40'-0"12/14/2020 8:32:14 PMAS.2EXISTING PARKING PLAN (FORREFERENCE ONLY)POOL DECK IMPROVEMENTS forAUTHOR08/06/20202017.15019608 Pruneridge AveCupertino, CA 950141" = 40'-0"1PARKING PLAN - EXISTING (FOR REFERENCE ONLY)NO. DATE DESCRIPTION08/06/2020 PLANNING SETREF.NORTHTRUENORTH
LP
AS.41AS.42AS.43123TYP4BLDG. 5&6 MULTI-FAMILY RESIDENTIALBLDG. 3 MULTI-FAMILY RESIDENTIALBLDG. 2 MULTI-FAMILY RESIDENTIALBLDG. 4 MULTI-FAMILY RESIDENTIAL1111LEASING OFFICE110630 MINE CT.-SINGLE FAMILY RESID.10631 MINE CT.-SINGLE FAMILY RESID.10632 MINE CT.-SINGLE FAMILY RESID10633 MINE CT.-SINGLE FAMILY RESID.119701 PARKVIEW CT.SINGLE FAMILY RESIDENTIAL110605 N WOLFE RD.HOTEL -COURTYARD BY MARRIOTT 1COMMUNITY PARK1TO REMAIN(E) 19' - 8" SIDE SETBACKEXISTING BUILDING FOOTPRINTEXISTING CONCRETE PAVINGPROPERTY LINENEW RESYSTA WOOD DECK PAVING, SEE LANDSCAPE DWGS.CONCRETE PAVING WITH CONTROL JINTS, SEE LANDSCAPE DWGS.NEW CONCRETE WALLA. ALL ACCESSIBLE PARKING STALLS SHALL BE ADA COMPLIANT.B. CONTRACTOR TO FIELD VERIFY EXISTING TOW-AWAY SIGN AT THE PARKING ENTRANCE (S) DRIVE FOR COMPLIANCE, PROVIDE NEW AS REQ'D. SEE "AS.6" SHEETS FOR REFERENCE TO SITE SIGN DETAILS.C. THE ACCESSIBLE PARKING STALLS SHALL HAVE A MAXIMUM OF 2% PERMITTED SLOPE IN ANY DIRECTION.D. PATCH & REPAIR ALL AREA DAMAGED DUE TO ANY NEW CONSTRUCTION AS REQUIRED TO MATCH EXISTING OR BETTER.E. SEE "AS.6" SHEET FOR REFERENCES TO ALL SITE ADA DETAILS.F. ALL SITE CONDITIONS ARE EXISTING TO REMAIN, U.ON. SEE "AS.4" SHEETS FOR ADDITIONAL SITE INFORMATION.G. CONTRACTOR TO SUBMIT SHOP DRAWINGS & FINISH MATERIAL & SAMPLES TO ARCHITECT FOR REVIEW, PROVIDE MIN. 3'-0" X 3'-0" MOCK-UP SAMPLES OF ALL CONCRETE & PAINT FINISH, & ALL OTHER FINISH DEEMED NECESSARY FOR ARCHITECT REVIEW PRIOR TO PURCHASE / FABRICATION.SCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250SAN JOSE, CA 95110T:408.283.0100 ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTEN MATERIALS INDICATED HEREIN ARE THE WORK AND PROPERTY OF STUDIO G ARCHITECTS. THIS DOCUMENT MAY NOT BE DUPLICATED, REUSED OR DISCLOSED BY ANY METHOD WITHOUT THE WRITTEN CONSENT OF STUDIO G ARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSAs indicated12/15/2020 6:07:58 PMAS.3KEY SITE PLANPOOL DECK IMPROVEMENTS forEY08/06/20202017.15019608 Pruneridge AveCupertino, CA 950141" = 40'-0"1SITE PLAN - NEW KEY PLANNOTES: • SEE SHEET A0.1 FOR ADDITIONAL PROJECT CONDITIONS & REQUIREMENTS & GENERAL NOTES.• SEE SHEET AS.4 FOR ADDITIONAL INFORMATION AND ENLARGED PARTIAL SITE PLANS.• PARKINGS ARE EXISTING TO REMAIN, UON.• SEE CIVIL & LANDSCAPE DWGS. FOR MORE INFORMATION.• SEE LANDSCAPE DWGS. FOR NEW LIGHTING PLAN IN AREA OF WORK.• SEE LANDSCAPE DWGS. FOR NEW LANDSCAPE FURNITURE PLAN.• SEE SHEET AS.6 FOR GENERAL SITE PLAN DETAILS FOR REFERENCE ONLY.KeynotesLEGENDIndicated by x on the plansGENERAL NOTES1 (E) BUILDING, NOT IN SCOPE OF WORK.2 (E) ACCESSIBLE PARKINGS, SEE 3/AS.4.3 AREA OF NEW WORK, SEE 1/AS.4.4(E) PROPERTY LINE.NO. DATE DESCRIPTION08/06/2020 PLANNING SET1 12/14/2020 PLANNING REV.REF.NORTHTRUENORTH
12345675TYP8TYP95TYP1011127131314515161616TYP17TYP18TYP19202126TYP2728TYP33TYP34(E) SIDE SETBACK TO REMAIN19' - 9 1/2"(E) SIDE SETBACK TO REMAIN14' - 7 1/8"(E) FRONT SETBACK TO REMAIN
89' - 1"(E) REAR SETBACK TO REMAIN35' - 2"21' - 0"18' - 8 1/2"5' - 5"20'-0" 2' - 4"4' - 11"11' - 0"2262929322728242922TYP2324252829303120' - 2"353626EXISTING BUILDING FOOTPRINTEXISTING CONCRETE PAVINGPROPERTY LINENEW RESYSTA WOOD DECK PAVING, SEE LANDSCAPE DWGS.CONCRETE PAVING WITH CONTROL JINTS, SEE LANDSCAPE DWGS.NEW CONCRETE WALLA. ALL ACCESSIBLE PARKING STALLS SHALL BE ADA COMPLIANT.B. CONTRACTOR TO FIELD VERIFY EXISTING TOW-AWAY SIGN AT THE PARKING ENTRANCE (S) DRIVE FOR COMPLIANCE, PROVIDE NEW AS REQ'D. SEE "AS.6" SHEETS FOR REFERENCE TO SITE SIGN DETAILS.C. THE ACCESSIBLE PARKING STALLS SHALL HAVE A MAXIMUM OF 2% PERMITTED SLOPE IN ANY DIRECTION.D. PATCH & REPAIR ALL AREA DAMAGED DUE TO ANY NEW CONSTRUCTION AS REQUIRED TO MATCH EXISTING OR BETTER.E. SEE "AS.6" SHEET FOR REFERENCES TO ALL SITE ADA DETAILS.F. ALL SITE CONDITIONS ARE EXISTING TO REMAIN, U.ON. SEE "AS.4" SHEETS FOR ADDITIONAL SITE INFORMATION.G. CONTRACTOR TO SUBMIT SHOP DRAWINGS & FINISH MATERIAL & SAMPLES TO ARCHITECT FOR REVIEW, PROVIDE MIN. 3'-0" X 3'-0" MOCK-UP SAMPLES OF ALL CONCRETE & PAINT FINISH, & ALL OTHER FINISH DEEMED NECESSARY FOR ARCHITECT REVIEW PRIOR TO PURCHASE / FABRICATION.SCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250SAN JOSE, CA 95110T:408.283.0100 ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTEN MATERIALS INDICATED HEREIN ARE THE WORK AND PROPERTY OF STUDIO G ARCHITECTS. THIS DOCUMENT MAY NOT BE DUPLICATED, REUSED OR DISCLOSED BY ANY METHOD WITHOUT THE WRITTEN CONSENT OF STUDIO G ARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSAs indicated1/19/2021 8:51:00 PMAS.4ENLARGED SITE PLANPOOL DECK IMPROVEMENTS forEY08/06/20202017.15019608 Pruneridge AveCupertino, CA 95014NOTES: • SEE SHEET A0.1 FOR ADDITIONAL PROJECT CONDITIONS & REQUIREMENTS & GENERAL NOTES.• PARKING IS EXISTING TO REMAIN, UON.• SEE CIVIL & LANDSCAPE DRAWINGS FOR MORE INFORMATION.• SEE LANDSCAPE DRAWINGS FOR NEW LIGHTING PLAN IN AREA OF WORK.• SEE LANDSCAPE DRAWINGS FOR NEW LANDSCAPE FURNITURE PLAN.• SEE SHEET AS.6 FOR GENERAL SITE PLAN DETAILS, FOR REFERENCE ONLY.KeynotesLEGENDIndicated by x on the plansGENERAL NOTES1/8" = 1'-0"1ENLARGED PARTIAL SITE PLAN - AREA OF NEW WORK3/16" = 1'-0"2ENLARGED ADA PARKING A3/16" = 1'-0"3ENLARGED ADA PARKING B1 (N) CONCRETE BBQ COUNTER.2 (N) 36" NATURAL GAS GRILL, PROVIDE DEDICATED GAS CONNECTION AS REQUIRED.3 (N) AC/DC POWERED TOUCHLESS FAUCET WITH SOAP DISPANCER, PROVIDE DEDICATED ELECTRICAL AND WATER CONNECTION ASREQUIRED.4 (N) BUILT-IN WOOD TABLE AND BENCH.5 (N) CORE-TEN TRELISS.6 (N) RESYSTA WOOD FENCE.7 (N) WOOD LOUNGE SEAT WITH BACK.8 (N) CONCRETE PLANTER WALL.9 (E) CONCRETE PAVING.10 (N) RESYSTA WOOD DECK PAVING.11 (N) RESYSTA WOOD STEPS WITH S.S HANDRAIL.12 (N) CONCRETE STEPS WITH S.S HANDRAIL.13 (E) BUILDING, NOT IN SCOPE OF WORK.14 (N) COMPOSITE WOOD FENCE.15 (N) 4'X8' PAVER GRATE.16 (N) GATE.17 CONCRETE PAVING WITH CONTROL JOINTS.18 (N) CUBBLE MULCH.19 REQUIRED 30" X 48" CLEAR & UNOBSTRUCTED ACCESSIBLE AREA.20 (N) ADA ACCESS, 4.8% WALK WAY. SEE LANDSCAPE PLANS FOR ADDITIONAL INFORMATION.21 (E) HOT TUB.22 (E) ACCESSIBLE PATH AT ACCESSIBLE PARKING STALL TO REMAIN, NO CHANGE.23 (E) INTERNATIONAL SYMBOL OF ACCESSIBLE LOGO AT PARKING STALL, SEE DETAIL.24 (E) ACCESSIBLE STRIPING WITH LETTERS READING "NO PARKING" TO REMAIN, SEE DETAIL.25 (E) VAN ACCESSIBLE PARKING SIGN TO REMAIN. SEE DETAIL.26 (E) SIDEWALK TO REMAIN27 (E) PARKING STRIPING TO REMAIN, U.O.N -TYP28 (E) DRIVEWAY.29 (E) CURB RAM TO REMAIN, TYP. SEE LANDSCAPE DWGS.30 (E) VAN ACCESSIBLE PARKING TO REMAIN.31 (N) DETECTABLE WARNING DOMES, SEE AS.6 FOR DETAIL.32 (E) DETECTABLE WARNING DOMES TO REMAIN, SEE DETAIL.33 (E) PROPERTY LINE.34 (E) TREES, SEE LANDSCAPE DWGS35 (E) ACCESSIBLE PARKING SIGN TO REMAIN, SEE REF DETAIL.36 (E) ACCESSIBLE PARKING TO REMAIN.REF.NORTHTRUENORTHNO. DATE DESCRIPTION08/06/2020 PLANNING SET1 12/14/2020 PLANNING REV.2 01/19/2021 PLANNING REV.
SCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250SAN JOSE, CA 95110T:408.283.0100 ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTEN MATERIALS INDICATED HEREIN ARE THE WORK AND PROPERTY OF STUDIO G ARCHITECTS. THIS DOCUMENT MAY NOT BE DUPLICATED, REUSED OR DISCLOSED BY ANY METHOD WITHOUT THE WRITTEN CONSENT OF STUDIO G ARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESS12/14/2020 8:28:15 PMAS.5EXISTING SITE IMAGES ( FORREFERENCE ONLY)POOL DECK IMPROVEMENTS forTB08/06/20202017.15019608 Pruneridge AveCupertino, CA 95014NO. DATE DESCRIPTION08/06/2020 PLANNING SET1. FROM PARKING LOT TOWARDS CLUBHOUSE2. FROM PARKING LOT TOWARDS POOL DECK3. POOL DECK TOWARDS HOUSING5. POOL DECK TOWARDS WEST LAWN6. POOL DECK LOOKING WEST4. CLUBHOUSE FROM POOL DECK7. POOL DECK EXTERIOR FENCE FROM LINNET LANE
DETECTABLE WARNING, SEE ACCESSIBLE CURB RAMP DETAIL, TYPACCESSIBLE PARKING SIGN1:12 MAX SLOPE @ RAMPLEVEL LANDING 1:50 MAX FLUSH WITH DRIVENO PARKING3' WIDE STRIPING3' CONCRETE WHEEL STOP SEE 8/A1.3RAMPVANNO PARKINGINTERNATIONAL ACCESSIBILITY SYMBOL 36" SQ.CBSTRIPING FOR VAN ACCESSIBLE PARKINGSIGN TYPE 'B'ATHE ACCESS AISLE IS MARKED BY A BORDER & HATCHED LINES THAT ARE PAINTED BLUE."NO PARKING" PAINTED IN 12" HIGH LETTERS WITHIN STRIPING1. ACCESSIBLE SPACE MUST PERMIT USE OF EITHER CAR DOOR.2. WHEEL STOP REQUIRED WHEN NO CURB OR BARRIER IS PROVIDED WHICH WILL PERVENT ENCROACHMENT OF CARS OVER WALKWAYS. 3. WHEELCHAIR USERS MUST NOT BE FORCED TO GO BEHIND PARKED CARS OTHER THAN THEIR OWN.4. MAX. CROSS SLOPE OF 1:50, ALL WLAKS.5. 12" MIN. BORDER GROOVES TOP OF CURB RAMOS TYP. 1/4" X 1/4" AT 3/4" O.C. SEE DETAIL 6/A1.3.6. PROVIDE DETECTABLE WARNING THAT EXTENDS FULL LENGTH AND WIDTH OF CURB RAMP APPROACH INTO PARKING LOT. MANUFACTURER: WAUSAU TRUNCATED DOMES, 12"X12" SIZE, CAST IN CONCRTE, COLOR: GREY. SEE DETECTABLE WARNING DETAIL THIS SHEET.7. SURFACE OF THE ACCESSIBLE PARKING SPACES & ACCESSIBLE AISLES DO NOT EXCEED 2% GRADIENT IN ANY DIRECTION.8. DO NOTPAINT THE CURBS OR WHEEL STOPS BLUE, LEAVE NATURAL CONCRETE, TYPICAL.(*)12' - 0" MINMIN (*)5' - 0"9' - 0" MIN18' - 0" MIN3' - 0"18' - 0" MIN9' - 0" MINMIN5' - 0"9' - 0" MIN3' - 0"NO PARKING9' - 0" MINMIN5' - 0"18' - 0" MINNO PARKINGSTRIPING FOR STANDARD ACCESSIBLE PARKINGSTRIPING FOR SINGLE STANDARD ACCESSIBLE PARKINGRAMPRAMPRAMPRAMPMIN4' - 0"MIN4' - 0"RAMPMIN4' - 0"MIN4' - 0"MIN4' - 0"MIN4' - 0"(*) EXCEPTION: 12'-0" WIDE CAN BE REDUCED TO 9'-0" MIN. WIDTH FOR VAN ACCESSIBLE STALL IF ACCESSIBLE AISLE IS 8'-0" WIDE MIN.SIGN TYPE 'A'SIGN TYPE 'A'ALIGNVAN ACCESSIBLEACCESSIBLEPLATE OR PERMITONLYRESERVEDSIGN TYPE "A"CAP POST TOP TYP.ATTACH SIGN TO POST AT TOP & BOTTOMSTEEL SIGN W/ BLUE LETTERING AND BLUESYMBOL ON WHITE BACKGROUND, TYP.ADD VAN ACCESSIBLE SIGN AT TYPE "B"SUPPORT: 2" DIA. STEEL PIPEFINISH GRADECONCRETE FOOTING 1'-0" DIA.COMPACTED SUBGRADE TO 95% OF MAX.SIGN TYPE A- AS SHOWN, SIGN TYPE B- INCLUDES VAN ACCESSIBLE SIGNMINIMUM FINE $250"MINIMUM FINE $250" REQUIRED TO BEPLACED BELOW BOTH TYPE "A" & TYPE "B"SIGNSMIN.6"-8"1' - 0"1' - 6"1' - 6"6" RAD., TYP.2-1/2" RADIUSBLUE BACKGROUND2" WIDE WHITE STROKE, TYP.PARKING STALL℄EDGE OF PARKING STALL1' - 2"2"1 1/2"3"1' - 0"1 1/2"6"1 ' - 1 "3' - 0"1' - 1"1' - 1"1 1/2"R10"3' - 0"ALIGNTOOLED EDGE, TYP.1/2" PRE-MOLDED JOINTAC PAVINGCOMPACTED SUBGRADE TO 95% OF MAX.#4 T&B1"MIN2"5"ALIGN▲ PLAN▲ SECTION▲ TRUNCATED DOME SPACINGSET IN CONCRETE, FLAT PORTION FLUSH, TYP.℄℄℄BASE DIAMETER0.9" - 0.92"TOP DIAMETER0.45" - 0.47"APART2.3" - 2.4"℄HEIGHT0.2".TOP DIAMETER0.45" - 0.47"BASE DIAMETER0.9" - 0.92"APART2.3" - 2.4"TOP DIAMETER0.45" - 0.47"BASE DIAMETER0.9" - 0.92"APART2.3" - 2.4"NOTE: PROVIDE DETECTABLE WARNING THAT EXTENDS FULL LENGTH AND WIDTH OF CURB RAMP APPROACH INTO PARKING LOT. MANUFACTURER: WAUSAU TRUNCATED DOMES, 12"X12" SIZE, CAST IN CONCRTE, COLOR: DARK GREY. SEE DETECTABLE WARNING DETAIL THIS SHEET.PRE-CAST CONCRETE BUMPER, 3'-0" LONG W/ (2) #3 REBARSAC PAVING OVER AGGREGATE BASEROCKCOMPACTED SUBGRADE TO 95% OF MAX.3"2"3"3"3"(2) #6 GALV DOWELS 24" LONG, 9" FROM EA. END OF BUMPERFRONT OF PARKING STALL2' - 0"DO NOT PAINT BLUENOTE: DO NOTPAINT WHEEL STOPS BLUETOOLED EDGE, TYP.1/2" PRE-MOLDED JOINTAC PAVING OVER BASEROCKCOMPACTED SUBGRADE TO 95% OF MAX.FINISH GRADE1"5"NOTE: BOTTOM OF NEW CURBEXTENDS 2" BEYOND BOTTOM OFEXISTING BASE ROCKEXISTINGNEW DETECTABLEWARNING, SEE DETAIL 7.FLARED SIDES AT 1:10MAX.RAMP SLOPE AT 1:12MAX.NEW DETECTABLEWARNING, SEE DETAIL 7.MIN.4' - 0"MIN.4' - 0"3' - 0"FLAT LANDING 2% MAX. SLOPE IN ANY DIRECTION.PLACARDS OR SPECIALOR BY TELEPHONINGMAY BE RECLAIMED ATTOWED VEHICLESOWNER'S EXPENSE.TOWED AWAY AT THEDISABILITIES WILL BEFOR PERSONS WITHLICENSE PLATES ISSUEDACCESSIBLE SPACES NOTPARKED IN DESIGNATEDUNAUTHORIZED VEHICLESDISPLAYING DISTINGUISHINGCAP POST TOP TYP. SIGN LETTERS: SIGNLETTERS: MIN. 1" HIGH BLANK SPACESARE TO BE FILLED IN WITH APPROPRIATEINFORMATION AS A PERMANENT PART OFTHE SIGN SIGN MATERIAL:REFLECTORIZED PAINT OR PORCELAIN ONMETAL SIGN COLORS: WHITE LETTERS ONBLUE BACKGROUND EQUAL TO NO.15090 FEDERAL STANDARD 595BOPTION: COMPLYING WITH 24 CAC Sec.2-7102SUPPORT: STANDARD GALVANIZED STEELCHANNEL "U" POSTFINISH GRADECONCRETE FOOTING 1'-0" DIA.COMPACTED SUBGRADE* CONTRACTOR SHALL PROVIDE SIGNS IF SIGN ISNOT CURRENTLY LOCATED AT ENTRY DRIVES ORADJACENT TO ACCESSIBLE PARKING , V.I.F.* VERIFY VEHICLE RECLAIM SERVICE AND PHONENUMBER WITH BUILDING OWNER.3'-0" TYP.4"7'-0" MAX. (N.T.S.)1' - 10" MIN.1' - 5"1' - 0"3"A-9 TOWING510-244-2806TOOLED EDGE, TYPICALMATCH (E)1/2" PREMOLDEDJOINT, MATCH CONC.COLOR, SUBMIT SAMPLE OF SEALANT FOR ARCHITECT REVIEWCONCRETE WALK OVER BASEROCK, FINISH TO MATCH (E)COMPACTEDSUBGRADETO 95% OFMAX.#4 T&B RE-INFORCINGCLASS II AGGREGATE BASE, DEPTH TO MATCH (E), 6" MIN.6X6 / 10X10 W.W.F. AT MID SECTION(E) CONC WALKNEW CONCRETE FTG.:MATCH (E) DIMENSION OF BOTTOM OF BASE ROCK OR 12" MIN. WHICHEVER IS GREATERMIN4"MATCH (E)CONCRETE WALK, FINISHTO MATCH (E)TOOLED JOINT6X6 / 10X10 W.W.F. ATMID SECTIONCOMPACTED SUBGRADETO 95% OF MAX.NOTE: FOR ADDITIONAL INFORMATION, SEE STRUCTURAL DWGS.#4 T&B REINFORCING6"6"4"1" - 3"TOOLED JOINTEXISTING ASPHALT DRIVEOVER BASE ROCKCOMPACT SUB-GRADE TO 95% OF MAX.CLASS II AGGREGATE BASEROCK DEPTH TO MATCH (E), 6" MIN.DETECTABLE WARNINGS, SET INCONCRETE. SEE 7/A1.3.1/2" SEALANT (MATCH CONC.COLOR) SUBMIT SAMPLE OFSEALANT FOR ARCHITECT REVIEW.8"8"NEW CONCRETE FTG.: MATCH (E) DIMENSION OF BOTTOM OF BASE ROCK OR 12" MIN.WHICHEVER IS GREATERCONCRETE WALK OVER BASEROCK, FINISH TO MATCH (E)BORDER IMAGE SHALL BE WHITE ON BLUE BACKGROUND UNLESS LIGHT ON DARK OR DARK ON LIGHT PATTERN OF OTHER COLORS IS PERMISSIBLE BY LOCAL BUILDING AUTHORITYINSTALL INTERNATIONAL ACCESSIBILITY SYMBOL IN LOCATIONS AS REQUIRED BY CODE.SIGNS SHALL BE MOUNTED ON APPROACH SIDE OF THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, SIGN SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLE ON THE RIGHT.PICTOGRAM FIELD, 6" MIN.LOCATE C OF SIGN 60" A.F.FEXCEPT AT CHECK-OUT COUNTERS,SCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250SAN JOSE, CA 95110T:408.283.0100 ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTEN MATERIALS INDICATED HEREIN ARE THE WORK AND PROPERTY OF STUDIO G ARCHITECTS. THIS DOCUMENT MAY NOT BE DUPLICATED, REUSED OR DISCLOSED BY ANY METHOD WITHOUT THE WRITTEN CONSENT OF STUDIO G ARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSFOR REFERENCE ONLYAs indicated12/14/2020 8:28:42 PMAS.6SITE DETAILSPOOL DECK IMPROVEMENTS forEY08/06/20202017.15019608 Pruneridge AveCupertino, CA 950143/32" = 1'-0"2TYP. ADA PARKING SPACES1" = 1'-0"5TYP. RESERVED ADA PARKING SIGN3/4" = 1'-0"4INTERNATIONAL SYMB. OF ACCESSIBILITY1 1/2" = 1'-0"10CONCRETE CURB3" = 1'-0"7TYP. DETECTABLE WARNING1 1/2" = 1'-0"8CONCRETE WHEELSTOP1 1/2" = 1'-0"11CONCRETE CURB AT LANDSCAPE1/4" = 1'-0"12ACCESSIBLE CURB RAMP1" = 1'-0"6TYP. ADA PARKING TOWAWAY SIGN1 1/2" = 1'-0"13CONCRETE TIE TO EXIST. CONCRETE1 1/2" = 1'-0"14TYP. PEDESTRIAN WALK AT LANDSCAPING1 1/2" = 1'-0"9PEDESTRIAN WALK AT DRIVEWAY3" = 1'-0"3INT. SYM. OF ACC. SURFACE MOUNTEDNO. DATE DESCRIPTION08/06/2020 PLANNING SET
6" SD ~8LF6" SD ~7LF4" PERF ~29LF4" PERF ~12LF4" PERF ~14LF4" PERF ~33LF4" PERF ~23LF4" PERF ~72LF4" PERF ~20LF3231134" PERF ~16LF
4" PERF ~16LF
4" PERF ~16LF 326" SD ~9LF6" SD ~6LF6" SD ~29LF6" SD ~8LF6" SD ~7LF4" PERF ~29LF4" PERF ~12LF4" PERF ~14LF4" PERF ~33LF4" PERF ~23LF4" PERF ~72LF4" PERF ~20LF3231134" PERF ~16LF
4" PERF ~16LF
4" PERF ~16LF 326" SD ~9LF6" SD ~6LF6" SD ~29LFNORTH
SCALE: 1" = 10'05'15'20'10'PLANNING SUBMITTAL07.14.2020MARKET READY IMPROVEMENTS forGML, VAB07/14/20202017.150NO.DATEDESCRIPTIONSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgC4.0(650) 617-5930, Fax (650) 617-5932260 Sheridan Avenue, Suite 150S T R U C T U R A L & C I V I L E N G I N E E R SPalo Alto, CA 94306Plot Date:Dec 10, 2020 - 2:36 PM
HOHBACH-LEWIN #13229.31
Utility PlanUTILITY LEGENDUTILITY KEYNOTESCONNECT TO EXISTING STORM DRAIN SYSTEMEXISTING TRENCH/SLOTTED DRAIN TO BE CUT BACKTO NEW WALKWAY EDGEINSTALL NEW TRENCH DRAIN, SEE GRADINGLEGEND/SHEET L2.1 FOR TRENCH DRAINREQUIREMENTSCONNECT NEW SUBDRAINAGE SYSTEM TO EXISTINGSTORM DRAIN SYSTEMFIRE HYDRANTWATER VALVEWATER METERSTORM DRAIN MANHOLEBACKFLOW PREVENTERCATCH BASINAREA DRAINCLEANOUT TO GRADE1234FIRE DEPARTMENT CONNECTION
03/27/2019 03:31:07 PM MARKET READY IMPROVEMENTS forTS12/10/20202017.150NO.DATEDESCRIPTIONSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date12.09.2020PLANNING RE- SUBMITTAL12.10.2020TRUENORTHN1"=8'16'0'32'L1.0 LANDSCAPE SITE PLANLD.1 LANDSCAPE DEMO PLANLD.2 TREE DISPOSITION PLANLD.3 TREE PROTECTION DETAILSL1.1 LANDSCAPE LAYOUT PLANL1.2 LANDSCAPE MATERIAL PLANL1.3 LANDSCAPE FURNITURE PLANL1.4 LANDSCAPE LIGHTING PLANL1.4A LANDSCAPE LIGHTING CALCSL2.1 LANDSCAPE GRADING PLANL3.0 IRRIGATION LAYOUT PLANL3.2 IRRIGATION DETAILSL3.3 IIRRIGATION DETAILSL3.4 IRRIGATION NOTESL3.5 IRRIGATION NOTESL3.6 WATER USE CALCULATIONSL3.7 HYDROZONE LAYOUTLANDSCAPE SHEET LISTL4.1 LANDSCAPE PLANTING PLANL4.2 LANDSCAPE PLANTING IMAGESL5.1 LANDSCAPE SECTIONSL5.2 LANDSCAPE PERSPECTIVES
03/27/2019 03:31:07 PM MARKET READY IMPROVEMENTS forTS12/10/20202017.150NO.DATEDESCRIPTIONSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date12.09.2020PLANNING RE- SUBMITTAL12.10.20201"=8'1 #7C
03/27/2019 03:31:07 PM MARKET READY IMPROVEMENTS forTS12/10/20202017.150NO.DATEDESCRIPTIONSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date01.17.2021PLANNING RE- SUBMITTAL12.10.2020PLANNING RE- SUBMITTAL01.20.202121"=8'2 #22 #3
03/27/2019 03:31:07 PM MARKET READY IMPROVEMENTS forTS12/10/20202017.150NO.DATEDESCRIPTIONSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date12.09.2020PLANNING RE- SUBMITTAL12.10.20201"=8'
L1L1L1L1L1L1L1L2L2L2L2L2L2L3L3L3L3L3L3L1L1L2L2L1E1E103/27/2019 03:31:07 PM MARKET READY IMPROVEMENTS forTS12/10/20202017.150NO.DATEDESCRIPTIONSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date12.09.2020PLANNING RE- SUBMITTAL12.10.20201"=8'
2.23.03.98.38.47.88.34.42.13.74.14.14.12.43.24.12.22.01.81.61.10.81.01.11.21.12.33.14.01.61.31.10.90.80.60.70.80.80.92.02.73.41.31.10.90.70.60.60.60.70.80.91.72.22.71.10.90.70.60.50.60.60.70.91.01.41.94.66.06.76.76.66.86.56.13.61.91.41.10.90.70.60.50.50.40.40.50.50.60.80.91.22.08.79.39.410.48.59.59.88.01.21.62.02.42.72.82.92.92.72.41.91.51.20.90.80.60.50.50.40.40.40.50.60.70.91.11.41.92.73.23.53.53.43.22.92.41.12.011.11.81.81.81.71.51.31.10.90.70.60.40.40.30.20.20.20.10.10.10.10.10.10.20.30.30.40.40.40.30.31.01.12.47.111.011.012.511.12.73.23.74.04.14.03.73.22.71.02.213.41.21.92.12.21.92.93.43.94.34.44.34.03.52.90.92.10.50.60.60.60.60.50.20.20.20.20.30.30.40.40.50.60.81.01.21.51.92.42.93.43.94.24.34.23.93.42.90.82.10.40.50.50.50.50.50.40.40.40.40.40.40.50.50.60.70.91.01.31.61.92.42.83.34.03.73.32.80.72.00.30.40.40.40.40.40.40.40.40.40.50.50.50.60.70.80.91.11.41.72.02.42.83.53.22.80.72.00.20.30.30.30.30.40.40.40.40.40.50.50.60.60.70.81.01.21.41.82.12.52.93.63.22.80.72.00.20.30.30.30.30.30.30.40.40.40.40.50.60.60.80.91.11.31.61.92.32.73.23.93.53.10.61.90.20.20.20.30.30.30.30.30.40.40.50.50.60.70.80.91.11.41.72.12.63.14.54.13.50.61.90.20.20.20.20.30.30.30.30.40.40.50.50.60.70.81.01.21.51.92.32.93.64.35.85.44.84.10.51.50.20.20.20.20.20.30.30.30.40.40.50.50.60.70.91.11.31.72.12.63.34.14.95.86.56.97.16.96.45.64.70.30.60.40.10.10.10.20.20.20.20.30.30.30.40.40.50.60.70.80.91.11.41.82.22.93.64.65.66.67.48.08.27.97.36.45.40.20.20.10.10.10.10.20.20.20.20.30.30.30.40.40.50.60.70.81.01.21.51.92.43.14.05.06.27.38.28.89.08.78.07.05.90.10.10.10.10.10.10.20.20.20.20.30.30.30.40.40.50.60.70.81.01.31.62.02.63.34.25.46.67.88.89.59.79.48.67.56.30.10.10.10.10.10.10.20.20.20.20.20.30.30.40.40.50.60.70.91.11.31.72.12.73.54.55.66.98.29.310.010.29.99.17.96.60.10.10.10.10.10.10.20.20.20.20.20.30.30.40.40.50.60.70.91.11.41.72.22.83.64.65.87.28.59.610.310.510.29.38.26.80.10.10.10.10.10.10.10.20.20.20.20.30.30.40.40.50.60.70.91.11.41.82.22.93.74.76.07.38.79.810.510.710.49.58.47.00.10.10.10.10.10.10.10.20.20.20.20.30.30.40.40.50.60.80.91.11.41.82.32.93.84.86.17.58.89.910.710.910.59.78.57.10.10.10.10.10.10.10.10.20.20.20.20.30.30.40.40.50.60.80.91.21.41.82.33.03.84.96.17.58.910.010.710.910.69.88.67.20.10.10.10.10.10.10.10.20.20.20.20.30.30.40.40.50.60.80.91.21.51.82.33.03.84.96.27.68.910.010.811.010.79.88.67.20.10.10.10.10.10.10.10.20.20.20.20.30.30.40.40.50.60.80.91.21.41.82.33.03.84.96.27.68.910.110.811.010.79.88.67.30.10.10.10.10.10.10.10.20.20.20.20.30.30.40.40.50.60.80.91.21.41.82.33.03.84.96.27.58.910.010.811.010.69.88.67.20.10.10.10.10.10.10.10.20.20.20.20.30.30.40.40.50.60.70.91.11.41.82.32.93.84.86.17.58.810.010.710.910.69.78.57.10.10.10.10.10.10.10.10.10.20.20.20.30.30.40.40.50.60.70.91.11.41.72.22.93.74.86.07.48.79.910.610.810.59.68.47.10.10.10.10.10.10.10.10.10.20.20.20.30.30.40.40.50.60.70.91.11.41.72.22.83.64.65.97.28.59.610.410.610.29.48.26.90.10.10.10.10.10.10.10.10.20.20.20.30.30.30.40.50.60.70.81.01.31.62.12.73.54.55.77.08.39.410.110.310.09.28.06.70.10.10.10.10.10.10.10.10.20.20.20.20.30.30.40.50.50.70.81.01.21.62.02.63.34.35.46.78.09.09.79.99.68.87.76.40.10.10.10.10.10.20.20.20.20.30.30.40.40.50.60.80.91.21.51.92.43.14.05.16.37.58.49.19.39.08.27.26.00.10.10.10.10.10.10.20.20.20.30.30.40.40.50.60.70.91.11.41.72.22.93.74.75.76.87.78.38.48.27.56.65.50.10.10.10.10.10.10.20.20.20.20.30.30.40.50.50.70.81.01.21.62.02.63.34.15.16.06.87.37.47.26.65.84.80.10.10.10.10.10.10.20.20.20.20.30.30.40.40.50.60.70.91.11.41.82.22.83.54.35.05.66.06.16.05.54.80.10.10.10.10.10.10.10.20.20.20.20.30.30.40.50.60.70.81.01.21.51.92.42.40.10.10.10.10.10.10.10.20.20.20.20.30.30.40.40.50.60.70.91.11.31.61.91.60.10.10.10.10.10.10.10.60.80.91.11.31.61.20.10.10.10.10.10.10.10.10.50.60.80.91.11.21.10.00.00.10.10.10.10.10.10.10.50.60.60.70.91.01.00.00.00.00.10.10.10.10.10.10.10.00.00.00.10.10.10.10.10.10.10.00.00.00.00.10.10.10.10.10.10.00.00.00.00.10.10.10.10.10.10.00.00.00.00.00.10.10.10.10.10.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.003/27/2019 03:31:07 PM MARKET READY IMPROVEMENTS forTS12/10/20202017.150NO.DATEDESCRIPTIONSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date12.09.2020PLANNING RE- SUBMITTAL12.10.20201"=8'ScheduleSymbolLabelQuantityManufacturerCatalog NumberDescriptionLampNumber LampsFilenameLumens Per LampLight Loss FactorWattageA29ORGANIC LIGHTING.OLQL/('6LGH:DUP:KLWH3000K DecoLED1Deco - 3000K -- Top - 3.28ft -- 011601.ies1020.91.1B40BEULUX LIGHTINGYT01 Series- L270LED CLL620 - 0.04 W140Bilton- BL1-24058-IP00-40.IES40.856
03/27/2019 03:31:07 PM MARKET READY IMPROVEMENTS forTS12/10/20202017.150NO.DATEDESCRIPTIONSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date12.09.2020PLANNING RE- SUBMITTAL12.10.20201"=8'
CWSPOCSYMBOLMANUFACTURER/MODEL/DESCRIPTIONTORO DZK-700-1-DRIP VALVE KITDRIP CONTROL VALVE KIT. WITH 1" TORO 700 ULTRAFLOWINLINE VALVE, TORO Y-FILTER, AND 40 PSI PRESSUREREGULATOR AND FITTINGS. RANGES 0.25GPM-30GPM.TORO DB-PC DRIP BUBBLERPRESSURE COMPENSATING DRIP BUBBLER ON FLEXIBLE RISER.FLOW RATE AS NOTED. INSTALL TWO PER 15 GALLON TREE, 4PER 24" BOX TREE.INSTALL 2 EACH 318C ROOTWELL AERATION TUBES. CONTACTDARYL GREEN 949-548-7311AREA TO RECEIVE DRIPLINETORO RGP-218 (18)SUB-SURFACE PRESSURE COMPENSATING LANDSCAPEDRIPLINE WITH ROOTGUARD TECHNOLOGY. 0.53 GPHEMITTERS AT 18.0" O.C. DRIPLINE LATERALS SPACED AT 18.0"APART, WITH EMITTERS OFFSET FOR TRIANGULAR PATTERN.BURY 4" BELOW GRADE. ALL HEADERS AND FOOTERS PIPINGTO BE 3/4" IF FLOW IS BELOW 6 GPM AND 1" IF FLOW IS 7-15GPMSYMBOLMANUFACTURER/MODEL/DESCRIPTIONTORO 075-SLSCONE-PIECE, 3/4" SINGLE LUG, QUICK COUPLER VALVE WITHSTANDARD METAL COVER.MATCO-NORCA 514T BRASS GATE VALVE1/2"-4" BRASS GATE VALVE, FULL PORT, WITH SOLID WEDGE.IPS. WHEEL HANDLE. SAME SIZE AS MAINLINE PIPE. INSTALLIN A 10" ROUND VALVE BOX.HUNTER A2C-1200-M12-STATION CONTROLLER OUTDOOR METAL WALL MOUNTCABINET. INSTALL 5 ADDITIONAL EXPANSION MODULESA2M-600. INSTALL ON OUTSIDE WALL FOR MAINTENANCEACCESS. CONNECT HUNTER SOLAR SYNC WEATHER SESNORAND PROGRAMHUNTER WSS-SENWIRELESS SOLAR, RAIN FREEZE SENSOR WITH OUTDOORINTERFACE, CONNECT TO NEW HUNTER A2C CONTROLLER,INSTALL ON SW SIDE OF BUILDING AWAY FROMOVERHANGING STRUCTURES.EXISTING CONTROLLERREMOVE EXISTING CONTROLLER AND EXTEND ALL WIRES TONEW HUNTER CONTROLLER. PROGRAM CONTROLLERINCLUDING ALL EXISTING IRRIGATION ZONESPOINT OF CONNECTION 1"CONTRACTOR TO CONFIRM POC LOCATION, SIZE ANDPRESSURES AVAILABLE.IRRIGATION MAINLINE: PVC SCHEDULE 402020-07-08 19:02CWSPOCIRRIGATION LAYOUT PLANL3.0POINT OF CONNECTION (P.O.C).1.CONNECT IRRIGATION MAINLINE TO MAIN WATER SUPPLY ( SEE CIVIL ORARCHITECTURAL DRAWINGS FOR LOCATION). LANDSCAPE CONTRACTOR TO VERIFYLOCATION, SIZE, FLOW AND PRESSURES AVAILABLE AND TO NOTIFY LANDSCAPEARCHITECT OF ANY NECESSARY CHANGES NEEDED TO BE MADE SO THAT THEIRRIGATION SYSTEM PERFORMS TO AN IRRIGATION EFFICIENCY OF A MINIMUM OF81 PERCENT.2.SYSTEM MAXIMUM OPERATING PRESSURES. 80 PSI ( AT P.O.C) INSTALL PRESSUREREDUCER IF PRESSURES EXCEED EQUIPMENT MANUFACTURERS SUGGESTEDMAXIMUM OPERATING PRESSURES.3.SYSTEM MINIMUM OPERATING PRESSURES. 40 PSI (AT P.O.C)IRRIGATING AROUND EXISTING TREES.ANY IRRIGATION (MAINLINE OR LATERALS) WITH IN DRIP LINES OF EXISTING TREES SHALL BEFIELD APPROVED BY CONSULTING ARBORIST AND OR LANDSCAPE ARCHITECT PRIOR TO ANYTRENCHING WORK COMMENCES. HAND TRENCH AND OR FOLLOW ALL ARBORISTS/LANDSCAPEARCHITECTS RECOMMENDATIONS.DO NOT STACK OR STORE ANY MATERIALS, EQUIPMENT OR MACHINERY UNDER DRIP LINE OFEXISTING TREES.1.UPON COMPLETION OF LANDSCAPE AND IRRIGATION INSTALLATION THE LANDSCAPECONTRACTOR SHALL SUBMIT THE FOLLOWING AS REQUIRED BY CALIFORNIA MODELCERTIFICATION FROM LANDSCAPE ARCHITECT FOR INSTALLATION ACCORDING TO THEAPPROVED LANDSCAPE DOCUMENTATION PACKAGE.2.SOIL MANAGEMENT REPORT AND RECEIPTS FOR SOIL IMPROVEMENT PRODUCTS.3.LANDSCAPE MAINTENANCE MANAGEMENT REPORT.4.IRRIGATION MAINTENANCE MANAGEMENT REPORT.5.IRRIGATION SCHEDULE FOR NEW AND ESTABLISHED PLANT MATERIALS6.IRRIGATION AUDIT REPORT INDICATING SITE IRRIGATION EFFICIENCY,7.IRRIGATION DISTRIBUTION UNIFORMITY, ALL INSTALLED EQUIPMENT COMPLIES WITH APPROVED MWELO GUIDELINES.8.CERTIFICATE OF COMPLETION (COC) FORM.CONTACT LOCAL ENFORCING AGENCY FOR APPROVED SUBMITTAL FORMS AND PROCEDURES.NORTHMARKET READY IMPROVEMENTS forTS07/10/20202017.150NO.DATEDESCRIPTIONTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgPLANNING SUBMITTAL08.17.2020TATEOFCALI
FOR
NIA
LICENS
E
D
L
ANDSCAPEARCHITECTSignatureRenewal Date9.30.2021Date07.17.2020SCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSSTATEOFCALI
FOR
NIA
LICENS
E
D
L
ANDSCAPEARCHITECTSignatureRenewal Date9.30.2021Date07.17.2020SignatureRenewal Date9.30.2021Date07.17.2020PLANNING RE- SUBMITTAL12.10.2020
IRRIGATION DETAILSL3.27" WIDTH(17.8 CM)FRONT ELEVATIONRIGHT ELEVATION16" (40.7 CM) OPEN DOOR WIDTH234IRRIGATION CONTROLLER (A2C-SS) PERPLANIRRIGATION CONTROL WIRE IN CONDUITSIZE AND TYPE PER LOCAL CODESELECTRICAL SUPPLY CONDUIT CONNECTTO POWER SOURCE, J-BOX INSIDECONTROLLERADJACENT SURFACE TO MOUNTCONTROLLER PER PLANNOTE MOUNT CONTROLLER LCD SCREENAT EYE LEVEL, CONTROLLER SHALL BEHARD-WIRED TO GROUNDED 110 VACPOWER SOURCEHUNTER CONTROLLERHUNTER SOLAR SYNC RECOMMENDEDMOUNTING SITEDO NOT PLACE UNDER TREE OROVERHANG OR ON FENCENOTES:1. DISTANCE FROM SENSOR TO CONTROLLERNOT TO EXCEED 500 LF2. SENSOR MAY BE SECURELY MOUNTED ONFENCE OR STEEL POST OR ON EAVE OFBUILDING.3. SENSOR SHOULD NOT BE MOUNTED UNDERTREES, IN AREAS AFFECTED BY SPRINKLERSYSTEM OR UNDER EAVE OF HOUSE.NorthHUNTER ACC2 CONTROLLER WITH SOLAR SYNCNTS1AB-IR-TIM-HUNT-0224" MIN. BELOW FIN. GRADEWATER SERVICE SHUT OFF VALVE10X14 STANDARD BOX, HEAT BRAND "SOV" ON LIDWITH 2" HIGH CHARACTERS.FINISHED GRADE.6" VALVE BOX EXTENTIONS, ASREQUIRED.PVC MAIN LINE, SIZE ASPER PLAN.1419 STANDARD VALVE BOX.PVC S REDUCER, ASREQUIRED.NIBCO T-580 BRONZEBALL VALVE.1/4 BEND COUPLING.WATER SERVICECONNECTION.TWO 6X2X16 CONC.BLOCK CAPS, ONE EACHSIDE OF BOX1/2" WIRE CLOTH GOPHERSCREEN, WRAP UP SIDES.WATER SERVICE CONNECTIONNTS3" APPROVED MULCH LAYER2AB-IR-POC-10NTSBRASS BALL ISOLATION VALVE10"X15" RECTANGULAR BOX WITH 6"EXTENSION.ISOLATION BALL VALVE ASSPECIFIED, SAME SIZE ASMAIN LINE.SCHEDULE 80THREADED NIPPLEAS REQUIRED.PVC MAIN LINE.TWO 6X2X16 CONCRETEBLOCK CAPS, ONE ONEACH SIDE OF BOX.1/2" WIRE CLOTH GOPHERSCREEN, WRAP UP SIDES.3AB-IR-POC-328406-10NOTES:1- SEE IRRIGATION LEGEND FOR MAINLINE AND LATERAL LINE PIPE SIZE AND TYPE.2- DIRECT BURIAL CONTROL WIRES SHALL BE INSTALLED IN SCH. 40 PVC ELECTRICAL CONDUIT IF REQUIRED.3- 2-WIRE IRRIGATION WIRE SHALL BE INSTALLED IN SCH. 40 PVC ELECTRICAL CONDUIT.4- DETECTABLE LOCATOR TAPE SHALL BE LOCATED SIX INCHES (6") ABOVE THE ENTIRE MAINLINE RUN.DIRECT BURIAL LOW VOLTAGECONTROL WIRES.PAVEMENT.IRRIGATION TRENCHINGNTS24" MIN.1'-0"
IN PLANTING AREA
1'-51 2" IN PLANTING AREA & WALKS
3'-0" UNDERNEATH TRAFFIC PAVEMENT
NON-PRESSURIZED LINE (LATERAL LINE).BACKFILL WITH 6" OF #2 SAND.DETECTABLE LOCATOR TAPE.PRESSURIZED LINE (MAINLINE).BACKFILL WITH 6" OF #2 SAND.6"FINISHED GRADE.4AB-IR-MAI-08DEPTH AS PER SPECIFICATIONS WIDTH VARIESMAINLINE & SLEEVING1 1/2" = 1'-0"BACKFILL WITH 100% COARSE SAND, WATERJET & MECHANICALLY COMPACT TO 90%OPTIMUM DENSITY. ALLOW 48 HOURS TOSETTLE, AND BACKFILL AND COMPACT WITHNATIVE SOIL.PVC MAIN LINEBEDDINGNATIVE SOIL BACKFILL COMPACTTO 95% COMPACTIONFINISHED GRADE4" MIN4" MIN.PVC SLEEVE. 2XSIZE OF PIPEAB-IR-MAI-075PAVINGPVC CAP (TYPICAL)SLEEVESDITCHPAVING24" MIN.
TO FINISH
GRADE 18" MIN.18" MIN.
24" MAX.4" MIN. CLEARANCESLEEVING DETAILNTS1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.2. DO NOT SCALE DRAWINGS.3. ALL PVC IRRIGATION SLEEVES TO BE CLASS 200 PIPE.4. ALL JOINTS TO BE SOLVENT WELDED AND WATERTIGHT.5. WHERE THERE IS MORE THAN ONE SLEEVE, EXTEND THE SMALLER SLEEVE TO 24" MINIMUM ABOVE FINISH GRADE.6. MECHANICALLY TAMP TO 95% PROCTOR.6AB-IR-MAI-328409-06MINIMUM BEARING SURFACE AREAPIPE SIZETEE AND PLUG90° BEND45° BEND1-1/2"0.45 FEET ²0.63 FEET ²0.34 FEET ²2"0.69 FEET ²2-1/2"1.0 FEET ²3"1.48 FEET ²4"2.43 FEET ²6"5.25 FEET ²8"9.08 FEET ²10"14.93 FEET ²0.97 FEET ²1.41 FEET ²2.10 FEET ²3.45 FEET ²7.41 FEET ²12.83 FEET ²21.07 FEET ²0.53 FEET ²0.77 FEET ²1.14 FEET ²1.87 FEET ²4.02 FEET ²6.96 FEET ²11.44 FEET ²THRUST BLOCK (2)NTSNOTES:1- SIZE THRUST BLOCKS SHALL BE SPECIFIED AS SHOW IN THE TABLE ABOVE.2- CONTROL WIRES SHALL NOT BE ENCASED IN CONCRETE.3- ALL FITTINGS SHALL BE WRAPPED WITH POLYETHYLENE TO PREVENT CONCRETE FROM ADHERING TO PIPE, FITTINGS OR BOLTS.4- JOINTS AND BOLTS SHALL BE ACCESSIBLE FOR REPAIRS.5- THRUST BLOCKS SHALL BE A MINIMUM OF 6" THICK.6- ONE 80 LBS. SACK OF CONCRETE SHALL COVER .6 FT.³BEARING SURFACE.BEARING SURFACE.EXISTING OR MODIFIED SOIL. (SEE SPECIFICATIONS FORSOIL MODIFICATION).7AB-IR-MAI-121'-0"1'-0"1'-0"1'-0"BVICVMVQCVGRJUMBO RECTANGULARVALVE BOX(22" X 16" X 12")STANDARDRECTANGULARVALVE BOX(18" X 12" X 12")2'- 0"
Typ.Wate
r
t
ype
Cont
ro
l
le
r
Des
igna
t
ion
Box
s
i
ze
L
id
Co
lo
r # 1# 2# 2# 3# 4IDENTIFICATION GUIDEPWPWPWPWPWPWPWPWPWPWPWPWPWAAAAAAAAAAAAAMVFSHMBVBVGVARVQCVRCVMSGRSBFC# 2# 2# 2# 2# 1# 2# 2# 3# 2# 2# 4# 3# 3Match top dressMatch top dressMatch top dressMatch top dressMatch top dressMatch top dressMatch top dressMatch top dressMatch top dressMatch top dressMatch top dressMatch top dressMatch top dressMaster valveFlow sensorHydrometerBall valve 3" or lessBall valve 4" or moreGate valveAir release valveQuick coupler valveRemote control valveMoisture sensorGrounding rodSplice boxFuture connectionEXAMPLEPOTABLE WATER SYSTEM ON CONTROLLER 'A', REMOTECONTROL VALVE STATION # 3. (ALL NON POTABLE SHALL BEPURPLE)PAVEMENT,WALL, ORBUILDING.NOTES:1- LOCK ALL VALVE BOXES WITH BOLT PROVIDED2- VALVE BOXES SHALL BE LABELED BY HOT IRON BRANDING ORBRASS NUMBER TAG3- LOCATE VALVE ASSEMBLIES IN PLANTING OR TURF AREA.4- VALVE LOCATIONS SHALL BE APPROVED BY THE OWNER'SREPRESENTATIVE PRIOR TO INSTALLATION.5- VALVE BOXES SHALL BE CENTERED ABOVE VALVE ASSEMBLIESTO FACILITATE ACCESS AND MAINTENANCE.6- VALVE BOXES SHALL BE FLUSH WITH TURF OR 3" ABOVEGRADE FOR MULCH INSTALLATION.7- VALVE BOXES SHALL BE SET PARALLEL TO EACH OTHER ANDPERPENDICULAR TO THE EDGE OF PAVEMENT.8- SEE OTHER IRRIGATION DETAILS FOR FURTHER INFORMATION.STANDARDRECTANGULARVALVE BOX(18" X 12" X 12")CIRCULARVALVE BOX(10" D)CIRCULARVALVE BOX(6" D)COMMERCIAL VALVE BOX LAYOUTDO NOT SCALE8AB-IR-VAL-VALV-328406-01STEP 1: STRIP WIRES 12" FROMENDS.STEP 2: APPLY SIZED WIRE NUTAND TURN CLOCKWISE DIRECTION.STEP 3: INSERT SPLICE INTO 3MGEL FILLED CLEAR TUBE. PUSH SOTHAT THE WIRE NIT MAKESCONTACT WITH END OF TUBE.STEP 4: POSITION WIRES INCHANNELS AND CLOSE TUBECOVER.NOTE:MAXIMUM WIRES PERCONNECTOR ARE THREE EACH #14's OR TWO EACH # 12's.3M-DBYR WIRE SPLICESNTS9AB-IR-VAL-1618" min.PLAN VIEWSECTION VIEWPRESSURE COMPENSATING BUBBLER SHALL BESET 1" ABOVE FINISHED GRADE. (SEEIRRIGATION LEGEND FOR MAKE AND MODEL).SWING JOINT FROM FLEX HOSE.FINISHED GRADE.SCH. 40 PVC 90° ELBOW SLIP TO THREAD.LATERAL LINE IRRIGATION. (SEE IRRIGATIONPLANS FOR SIZING).SCH. 40 PVC 90° ELBOW SLIP TO THREAD.SCH. 40 PVC TEE OR 90° ELBOW.EDGE OF ROOT BALL.EXISTING OR MODIFIED SOIL. (SEESPECIFICATIONS FOR SOIL MODIFICATION).LATERAL LINE IRRIGATION. (SEE IRRIGATIONPLANS FOR SIZING).NOTES:1- ALL IRRIGATION FITTINGS SHALLBE SCH. 40 PVC UNLESS SPECIFIEDOTHERWISE.2- ALL THREADED CONNECTIONSFROM SCH. 40 TO SCH. 80 PVCSHALL BE MADE USING TEFLONTAPE.3- CONTRACTOR SHALL SETTLE THEAREA AROUND THE BUBBLER ANDEDGE OF THE ROOT BALL SO THATALL IRRIGATION FLOWS THROUGHTHE ROOT BALL.EDGE OF ROOT BALL. SETTLE BACKFILL SO THATIRRIGATION FLOWS THROUGH THE ROOT BALL.SWING JOINT. SEE DETAIL.TREE BUBBLER (4) LAYOUT3/4" = 1'-0"10AB-IR-TRE-02MARKET READY IMPROVEMENTS forTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSSTATEOFCALI
FOR
N
IA
LICENS
E
D
L
ANDSCAPEARCHITECTSignatureRenewal Date9.30.2021Date07.17.2020TS07/10/20202017.150NO.DATEDESCRIPTIONPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date07.17.2020PLANNING RE- SUBMITTAL12.10.2020
IRRIGATION DETAILSL3.31 1/2" = 1'-0"1" DRIP VALVE/FILTER/REGULATORFILTER AS SPECIFIED.SxT TEE W/ 2" NIPPLE ATMAINLINE.PRESSURE REGULATOR ASSPECIFIED.PVC TRUE UNION BALLVALVE.20"X17" JUMBO PLASTICVALVE BOX.3" ABOVE GRADE ATSHRUBS.RCV AS SPECIFIED.CONTROLLER WIRE WITH 30 INCH LINEAR LENGTHOF COIL, WITH PLASTIC I.D. TAG AND WATERPROOFCONNECTORS.12" BELOW
GRADE.12" WIRE CLOTH GOPHERSCREEN, WRAP UP SIDES.12" DRAIN ROCK FILL45° DOWN AS REQ. TOLATERAL PIPE DEPTH.OUTLET PIPE SAME SIZE ASVALVE, 24" MIN. LENGTH TOFIRST FITTING.PVC UNION W/ SHORT NIPPLES.3" MIN.SET BOX FLUSH ATTURF.SCH. 80 RISER.HOUSE BRICK.CHRISTY ID TAG.1AB-IR-DRI-VALV-328413-021" ABOVE FINISH GRADE.FINISH GRADE.6" ROUND PLASTIC VALVE BOX.HEAT BRAND "AR" ON LID IN 1"HIGH CHARACTERS.TORO DL2000 AIR/VACUUMRELIEF VALVE (YD-500-34).TORO LOC-EZE X 1/2" FPT TEE(FTF16).TORO DL2000 TUBING(RGP-XX-XXX) OR TORO BLUESTRIPE POLY TUBING(EHD1645-XXX) AIR-RELIEFLATERAL.PEA GRAVEL SUMP (6" DEEP).BRICK SUPPORTS (2 COMMONBRICKS REQUIRED).NATIVE SOIL PERSPECIFICATIONS.765432189981234567SECTION/ELEVATIONNOT TO SCALELEGEND:NOTES:1. USE ONE AIR/RELIEF VALVE FOR EVERY 7 GPM PER ZONE. LOCATE AT HIGH POINTS. REFER TO TORO PUBLICATION #ALT111 FOR SPECIFICATIONS.2. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.3. DO NOT SCALE DRAWING.4. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS,CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES ONLY. THIS DRAWINGMAY NOT BE USED FOR CONSTRUCTION.5. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUSTBE REVIEWED AND APPROVED BY THE PRODUCT MANUFACTURER TO BE CONSIDERED ACCURATE.6.INSTALL PURPLE BOXES ON ALL NON POTABLE WATER PROJECTSTORO AIR RELIEF VALVENTS2AB-IR-DRI-INLI-17INSTALL POP-UP INDICATOR HEAD 24" OFF OFPAVEMENT OR THE EDGE OF PLANTED AREASERVED BY DRIP TUBINGNOTE: INSTALL INDICATOR HEAD 24" MAX FROM THE EDGE OF PAVING OR THE PLANTER EDGE. INSTALLYELLOW COLORED INDICATOR CAP ON XERI POP HEAD. FOR RECYCLED WATER USE A PURPLEIRRIGATION CAP.DRIP LINE TO BE INSTALLED 4" BELOWFINISHED SOIL GRADE, TYPICALSUBSURFACE DRIP TUBING, DEPTH ASSHOWN ON LEGEND AND DETAILAMMENDED SOILINSTALL POP-UP INDICATOR HEAD 2-3"ABOVE FINISHED GRADE IN SHRUB ANDGROUND COVER AREAS AND 12" FROMFLUSH VALVEPOP-UP INDICATOR HEAD, WITH AIRRIGATION FLUSH NOZZLE, YELLOWCOLORED AND PURPLE COLORED FOR NONPOTABLE SYSTEMS. PUSH CAP TO FLUSHSTREAM INTO PLANTER.6"6"2-3"4"RAIN BIRD XERI POP XP 600X DRIP INDICATOR OFF OF DRIP LINEBRICK SUPPORTSPEA GRAVEL SUMP (6" x 18").1" = 1"6" ROUND PLASTIC VALVE BOXWITH LOCKING LIDTORO DL2000 FLUSH VALVE(FCH-H-FIPT)TOP OF BOX 3" ABOVE FINISH GRADETO ALLOW FOR APPROVED MULCHLAYERMICRO-SPRAY POP-UP INDICATOR:RAIN BIRD XERI-POP XP-600X1/4" BARB TRANSFER CONNECTOR1/4" DISTRIBUTION TUBING:(LENGTH AS REQUIRED)3AB-IR-DRI-328413-06DRIP LINE LAYOUT AROUND TREE12345678924576811810911112313121314151016 Dripline Maximum Lateral Lengths (Feet)Inlet Pressure psi12" Spacing18" Spacing24" SpacingNominal Flow (gph)Nominal Flow (gph)Nominal Flow (gph)0.60.90.60.90.60.9152731553142504243222031816935329450836830360230413350586414403952554654026524745041728552842072048860460290596455780514NTS817174AB-IR-DRI-DRIP-328413-01SLOPED CONDITION NOTE:1.DRIPLINE LATERALS SHOULD FOLLOW THE CONTOURS OF THE SLOPE WHENEVERPOSSIBLE.2.INSTALL AIR RELIEF VALVE AT HIGHEST POINT.3.NORMAL SPACING WITHIN THE TOP 23 OF SLOPE,4.INSTALL DRIPLINE AT 25% GREATER SPACING AT THE BOTTOM 13 OF THE SLOPE.5.WHEN ELEVATION CHANGE IS 10 FT OR MORE, ZONE THE BOTTOM 13 ON A SEPARATEVALVE.TYPICAL COMPRESSIONFITTING.DRIPLINE SPACING ASNOTED.AIR RELIEF VALVE ATHIGH POINT, IFINDICATED.CENTER FEED EXAMPLEEMITTER 12" 18" 24"FLOW SPACING SPACING SPACING0.6 GPH 1.0 GPM 0.67 GPM 0.50 GPM0.9 GPH 1.5 GPM 1.0 GPM 0.75 GPMLATERAL FLOW PER 100 FT (GPM)END FEED EXAMPLEFLUSH VALVE OR CAPAT LOW END, ASNOTED.TYPICAL DRIP LINE WITHEMITTER SPACING ASNOTED. TIE DOWNSTAKE AT ALL TEES, ELLS,AND AT 4' O.C. AT CLAY,3' O.C. AT LOAM, OR 2'O.C. AT SAND. EMITTER FLOW RATEEMITTER LATERALSPACING SPACING 0.6 0.9 12 12 0.96 1.44 18 18 0.69 1.03 24 24 0.28 0.41GRID PRECIPITATION RATES (IN/HR) MAX GPM PSI LOSSSCHEDULE 40 PVC HEADER SIZE1/2" 4.7 GPM 7.7 PSI3/4" 8.3 GPM 5.6 PSI1" 13.5 GPM 4.2 PSI1-1/2" 33.9 GPM 2.9 PSI2" 52.4 GPM 1.9 PSIPOLY PIPE HEADER SIZE1/2" 4.7 GPM 8.8 PSI3/4" 8.3 GPM 6.3 PSI1" 13.5 GPM 4.8 PSI1-1/2" 31.8 GPM 2.9 PSI2" 52.4 GPM 2.2 PSIMAXIMUM FLOW PER ZONE EMITTER FLOW RATE GPH 12" SPACING 18" SPACING 24" SPACINGPSI 0.6 0.9 0.6 0.9 0.6 0.910 125 96 175 135 218 17120 249 191 350 171 442 34030 307 236 434 333 550 42240 350 268 495 380 627 17150 125 96 175 135 218 17160 125 96 175 135 218 171MAXIMUM LATERAL LENGTH (FEET)TYPICAL FPT ADAPTER ANDCOMPRESSION COUPLER.DRIP VALVE / FILTER /REGULATOR.12" POLYETHYLENE ORPVC HEADER.TYPICAL OFFSET 2"FROM HARDSCAPE,4" FROM PLANTEDAREA.COMPRESSION ADAPTER:USE AN ABS TO PVC BONDING SOLVENTFOR GLUING ADAPTER TO PVC TEE.LANDSCAPEDRIPLINE TUBING.LANDSCAPE DRIPLINE TUBING.PVC MANIFOLD LINE WITHPVC TEE.WATER SOURCE: DRIP VALVE ORLATERAL FROM VALVE.FLUSH VALVEAIR RELIEF VALVE: RAIN BIRD ARVALVE KIT, INSTALL AT HIGH POINTOF SYSTEM.TYPICAL DRIPLINE REQUIREMENTSNTSPVC MAINLINE.3/4" PVC LATERALPIPE.PVC MANIFOLD LINE.DOGBONE SHAPEDCORNER SHAPEDCURVED POLYGONPOLYGON SHAPED"C" SHAPEDODD SHAPEDHOURGLASS SHAPEDDIDIDIDIDIDIDIDIDIDIDRIPLINE INDICATORDRIPLINE INDICATOR.6AB-IR-DRI-DRIP-19PVC EXHAUST HEADERPVC SCH 40 TEE OR EL (TYPICAL)BARB X MALE FITTING:FLUSH POINT (TYPICAL)PERIMETER OF AREAPERIMETER DRIPLINE PIPE TO BE INSTALLED 2"-4"FROM PERIMETER OF AREAON-SURFACE DRIPLINE:PVC SUPPLY HEADERPVC DRIP MANIFOLD FROM CONTROL ZONEVALVE KIT (SIZED TO MEET LATERAL FLOWDEMAND)PVC SCH 40 RISER PIPEDRIP INDICATOROTES:1. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED ON SOILTYPE, PLANT MATERIALS AND CHANGES IN ELEVATION. SEE INSTALLATIONSPECIFICATIONS ON RAIN BIRD WEB SITE (WWW.RAINBIRD.COM) FORSUGGESTED SPACING.2. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE MAXIMUMSPACING SHOWN IN THE ACCOMPANYING TABLE.3. WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE OVER 50PSI, IT ISRECOMMENDED THAT STAINLESS STEEL CLAMPS BE INSTALLED ON EACHFITTING.Dripline Maximum Lateral Lengths (Feet)Inlet Pressure psi12" Spacing18" Spacing24" SpacingNominal Flow (gph)Nominal Flow (gph)Nominal Flow (gph)0.60.90.60.90.60.9152731553142504243222031816935329450836830360230413350586414403952554654026524745041728552842072048860460290596455780514END FEED DRIP GRID SYSTEMNTS5AB-IR-DRI-DRIP-17MARKET READY IMPROVEMENTS forTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSSTATEOFCALI
FOR
N
IA
LICEN
SE
D
L
A
NDSCAPEARCHITECTSignatureRenewal Date9.30.2021Date07.17.2020TS07/10/20202017.150NO.DATEDESCRIPTIONPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date07.17.2020PLANNING RE- SUBMITTAL12.10.2020
IRRIGATION NOTESL3.4SECTION 32 8400 IRRIGATIONPART 1 GENERAL1.1SUMMARYA.Irrigation system required for this work includes but is not limited to the furnishing of all labor, tools, materials, appliances, tests,permits, taxes, etc., necessary for the installation of a landscape irrigation system as herein specified and shown on the drawings,and the removal of all debris from the site.1.Locate, purchase, deliver and install piping, conduit, sleeves, 120 volt and low voltage electrical and water connections, valves,backflow preventer devices, controllers, rain sensors, spray and bubbler heads, drip irrigation lines, and associated accessoriesfor a fully operational automatic irrigation system.2.Trenching and water settling of backfill material.3.Testing and startup of the irrigation system.4.Prepare an as built record set of drawings.5.Training of the Owner's maintenance personnel in the operational requirements of the Irrigation system.6.Clean up and disposal of all excess and surplus material.7.Maintenance of the irrigation system during the proscribed maintenance period.B.The system shall efficiently and evenly irrigate all areas and be complete in every respect and shall be left ready for operation to thesatisfaction of the Owner's Representative.C.Coordinate with other trades, as needed to complete work, including but not limited to Water Meter, Point of Connection (POC) andBackflow Preventer Device (BFPD) location and electrical hookups.1.2CONTRACT DOCUMENTSA.Shall consist of specifications and its general conditions and the drawings. The intent of these documents is to include all labor,materials, and services necessary for the proper execution of the work. The documents are to be considered as one. Whatever iscalled for by any part shall be as binding as if called for in all parts.1.3RELATED DOCUMENTS AND REFERENCESA.Related Documents: Refer to Landscape Documents or Landscape Architect provided documentation and specificationsReferences:1.American Society of Testing Materials (ASTM): cited section numbers.2.National Sanitation Foundation (NSF): rating system.3.Irrigation Association: Turf & Landscape Irrigation Best Management Practices1.4VERIFICATIONA.Irrigation piping and related equipment are drawn diagrammatically. Scaled dimensions are approximate only. Before proceedingwith work, carefully check and verify dimensions and immediately notify the Owner's Representative of discrepancies between thedrawings or specifications and the actual conditions. Although sizes and locations of plants and or irrigation equipment are drawn toscale wherever possible, it is not within the scope of the drawings to show all necessary offsets, obstructions, or site conditions. TheContractor shall be responsible to install the work in such a manner that it will be in conformance to site conditions, complete, and ingood working order.B.Piping and equipment is to be located within the designated planting areas wherever possible unless specifically defined ordimensioned otherwise.1.5PERMITS AND REGULATIONSA.The Contractor shall obtain and pay for all permits related to this section of the work unless previously excluded under provision ofthe contract or general conditions. The Contractor shall comply with all laws and ordinances bearing on the operation or conduct ofthe work as drawn and specified. If the Contractor observes that a conflict exists between permit requirements and the work outlinedin the contract documents, the Contractor shall promptly notify the Owner's Representative in writing including a description of anynecessary changes and changes to the contract price resulting from changes in the work.B.Wherever references are made to standards or codes in accordance with which work is to be performed or tested, the edition orrevision of the standards and codes current on the effective date of this contract shall apply, unless otherwise expressly set forth.C.In case of conflict among any referenced standards or codes or between any referenced standards and codes and thespecifications, the more restrictive standard shall apply or Owner's Representative shall determine which shall govern.1.6PROTECTION OF WORK, PROPERTY AND PERSONA.The Contractor shall adequately protect the work, adjacent property, and the public, and shall be responsible for any damages orinjury due to the Contractor's actions.1.7CHANGES IN THE WORKA.The Owner's Representative may order changes in the work, and the contract sum being adjusted accordingly. All such orders andadjustments plus claims by the Contractor for extra compensation must be made and approved in writing before executing the workinvolved.B.All changes in the work, notifications and Contractor's request for information (RFI) shall conform to the contract general conditionrequirements.1.8CORRECTION OF WORKA.The Contractor shall re-execute any work that fails to conform to the requirements of the contract and shall remedy defects due tofaulty materials or workmanship upon written notice from the Owner's Representative, at the soonest as possible time that can becoordinated with other work, and seasonal weather demands, but not more than 90 (ninety) days after notification.1.9DEFINITIONSA.Owner's Representative: The person appointed by the Owner to represent their interest in the review and approval of the work andto serve as the contracting authority with the Contractor. The Owner's Representative may appoint other persons to review andapprove any aspects of the work.B.Substantial Completion Acceptance: The date at the end of the Planting, Planting Soil, and Irrigation installation where the Owner'sRepresentative accepts that all work in these sections is complete and the Warranty period has begun. This date may be differentthat the date of substantial completion for the other sections of the project.C.Final Acceptance: The date when the Owner's Representative accepts that the plants and work in this section meet all therequirements of specification. It is intended that the materials and workmanship warranty for Planting, Planting Soil, and Irrigationwork run concurrently.1.10SUBMITTALSA.See the contract General Conditions for policy and procedures related to submittals.B.Product data1.Submit a minimum of (3) complete lists of all irrigation equipment to be used, manufacturer's brochures, maintenance manuals,warrantees and operating instructions, within 15 days after the notice to proceed.a.This submission may be done digitally and all documents shall be submitted in one PDF document.2.The submittals shall be packaged and presented in an organized manner, in the quantity described in Division 1 of thespecifications. Provide a table of contents of all submitted items.3.Clearly identify on each submitted sheet by underlining or highlighting (on each copy) the specific product being submitted forapproval. Failure to clearly identify the specific product being submitted will result in a rejection for the entire submittal. Nosubstitutions of material or procedures shall be made concerning these documents without the written consent of an acceptedequivalent by the Owner's Representative.4.Equipment or materials installed or furnished without prior approval of the Owner's Representative, may be rejected by theOwner's Representative and the Contractor shall be required to remove such materials from the site at their own expense.5.Approval of substitution of material and/or products, other than those specified shall not relieve the Contractor from complyingwith the requirements of the contract documents and specifications. The Contractor shall be responsible, at their own expense,for all changes that may result from the approved substitutions, which affect the installation or operations other items of their ownwork and/or the work of other Contractors.C.Samples: Samples of the equipment may be required at the request of the Owner's Representative if the equipment is other thanthat specified.D.Other Submittals: Submit for approval:1.Documentation of the installer's qualifications.2.As built record set of drawings.3.Testing data from all required pressure testing.4.Backflow prevention device certification: Certification from the manufacturer or their representative that the back flow preventiondevice has been installed correctly according to the manufactures requirements.5.Booster pump certification: Certification from the manufacturer or their representative that the booster pump has been installedcorrectly according to the manufacturer's requirements.6.Irrigation controller certification: Certification from the manufacturer or an authorized distributor that the Controller has beeninstalled correctly according to the manufactures requirements.1.11OBSERVATION OF THE WORKA.The Owner's Representative may inspect the work at any time. They may remove samples of materials for conformity tospecifications. Rejected materials shall be immediately removed from the site and replaced at the Contractor's expense. The cost oftesting materials not meeting specifications shall be paid by the Contractor.B.The Owner's Representative shall be informed of the progress of the work so the work may be observed at the following key times inthe construction process. The Owner's Representative shall be afforded sufficient time to schedule visit to the site. Failure of theOwner's Representative to make field observations shall not relieve the Contractor from meeting all the requirements of thisspecification.1.Trenching, directional boring, and sleeving review.2.Hydrostatic pressure testing.3.Adjustment and coverage test.4.Pre-maintenance observation.5.Final acceptance / system malfunction corrections.1.12PRE-CONSTRUCTION CONFERENCEA.Schedule a pre-construction meeting with the Owner's Representative at least seven (7) days before beginning work to review anyquestions the Contractor may have regarding the work, administrative procedures during construction and project work schedule.1.13QUALITY ASSURANCEA.It is the intention of this specification to accomplish the work of installing an automatic irrigation system, which will operate in anefficient and satisfactory manner. The irrigation system shall be installed and made operational according to the workmanlikestandards established for landscape installation and sprinkler irrigation operation as set forth by the most recent Best ManagementPractices (BMP) of the Irrigation Association.B.The specification can only indicate the intent of the work to be performed rather than a detailed description of the performance of thework. It shall be the responsibility of the Contractor to install said materials and equipment in such a manner that they shall operateefficiently and evenly and support optimum plant growth and health.C.The Owner's Representative shall be the sole judge of the true intent of the drawings and specifications and of the quality of allmaterials furnished in performance of the contract.D.The Contractor shall keep one copy of all drawings and specifications on the work site, in good order. The Contractor shall makethese documents available to the Owner's Representative when requested.E.In the event of any discrepancies between the drawings and the specification, the final decision as to which shall be followed, shallbe made by the Owner's Representative.F.In the event the installation is contradictory to the direction of the Owner's Representative, the installation shall be rectified by theContractor at no additional cost to the Owner. The Contractor shall immediately bring any such discrepancies to the attention of theOwner's Representative.G.It shall be distinctly understood that no oral statement of any person shall be allowed in any manner to modify any of the contractprovisions. Changes shall be made only on written authorization of the Owner's Representative.H.Installer Qualifications: The installer shall be a firm having at least 5 years of successful experience of a scope similar to thatrequired for the work.a.Installer Field Supervision: The installer shall maintain on site an experienced full-time supervisor who can communicate inEnglish with the Owner's Representative.b.Submit the installer's qualifications for approval.1.14IRRIGATION SYSTEM WARRANTY:A.The Contractor shall Warrantee all workmanship and materials for a period of 1year (s) following the acceptance of the work.6.Any parts of the irrigation work that fails or is defective shall be replaced or reconstructed at no expense to the Owner includingbut not limited to: restoring grades that have settled in trenches and excavations related to the work. Reconstruction shall includeany plantings, soil, mulch or other parts of the constructed landscape that may be damaged during the repair or that results fromsoil settlement.B.The date of acceptance of the work and start of the Guarantee period shall be determined by the Owner's Representative, upon thefinding that the entire irrigation system is installed as designed and specified, and found to be operating correctly, supplying waterevenly to all planting and/or lawn areas.C.The system controller shall be warranted by the equipment manufacturer against equipment malfunction and defects for a period of5 years, following the acceptance of the work.D.Neither the final acceptance nor any provision in the contract documents shall relieve the Contractor of responsibility for faultymaterials or workmanship. The Contractor shall remedy any defects within a period of 7 days (s) from the date of notification of adefect.1.15SITE CONDITIONSA.It is the responsibility of the Contractor to be aware of all surface and sub-surface conditions, and to notify the Owner'sRepresentative, in writing, of any circumstances that would negatively impact the installation of the work. Do not proceed with workuntil unsatisfactory conditions have been corrected.1.16DELIVERY, STORAGE, AND HANDLINGA.All materials and equipment shall be stored properly and protected as required by the Contractor. The Contractor shall be entirelyresponsible for damages or loss by weather or other cause to work under the contract. Materials shall be furnished in amplequantities and at such times as to ensure uninterrupted progress of the work.B.Deliver the products to the job site in their original unopened container with labels intact and legible at time of use.C.Store in accordance with the manufacturers' recommendations.1.17PROTECTIONA.The Contractor shall continuously maintain adequate protection of all their work from damage, destruction, or loss, and shall protectthe owner's property from damage arising in connection with this contract. Contractor shall make good any such damage,destruction, loss or injury. Contractor shall adequately protect adjacent property as provided by law and the contract documents.B.The Contractor shall maintain sufficient safeguards, such as railings, temporary walks, lights, etc., against the occurrence ofaccidents, injuries or damage to any person or property resulting from their work, and shall alone be responsible for the same if suchoccurs.C.All existing paving, structures, equipment or plant material shall be protected at all times, including the irrigation system related toplants, from damage by workers and equipment. The Contractor shall follow all protection requirements including plant protectionprovision of the general contract documents. All damages shall be repaired or replaced at the Contractor's expense. Repairs and orreplacement shall be to the satisfaction of the Owner's Representative, including the selection of a Contractor to undertake therepair or maintenance. Repairs shall be at no cost to the owner.1.For trees damaged to the point where they will not be expected to survive or which are severely disfigured and that are too largeto replace, the cost of damages shall be as determined by the Owner's arborist using accepted tree value evaluation methods.D.The Contractor shall refrain from trenching within the drip line of any existing tree to remain. The Owner's Representative mayrequire the Contractor to relocate proposed irrigation work, bore lines beneath roots or use air spade technology to dig trenchesthrough and under the root system to avoid damage to existing tree root areas.1.18EXCAVATING AROUND UTILITIESA.Contractor shall carefully examine the civil, record, and survey drawings to become familiar with the existing underground conditionsbefore digging.1.Do not begin any excavation until all underground utilities have been located and marked.Determine location of underground utilities and perform work in a manner that will avoid possible damage. Hand excavate, asrequired. Maintain stakes and or markings set by others until parties concerned mutually agree to their removal.B.Notification to 811 is required for all excavation around utilities. The Contractor is responsible for knowing the location and avoidingutilities that are not covered by the Local Utility Locator Service.C.Section 4216/4217 of the government code requires a dig-alert identification number be issued before a “permit to excavate” will bevalid. For your dig-alert identification number call underground service alert toll free 1-800-422-4133 two working days beforebeginning construction.1.19POINT OF CONNECTIONPoint of connection option 1 - Irrigation Contractor providedA.The point of connection of the irrigation system to its electrical power sources shall be provided by the irrigation installer. Allconnections shall be made by a licensed electrical Contractor per governing codes at the location shown on the drawings.B.The point of connection of the irrigation system to its potable and or non-potable water sources, including the main shutoff valve andbackflow preventer shall be provided by the irrigation installer. All connections shall be made by a licensed Contractor per governingcodes, at the location shown on the drawings.Point of connection option 2 - General Contractor providedA.The point of connection of the irrigation system to its electrical power sources shall be provided by the General Contractor's licensedelectrical Contractor per governing codes at the location shown on the drawings. The irrigation Contractor will connect the power toprovided junction box or grounded plug receptacle.B.The point of connection of the irrigation system to its potable and or non-potable water sources, including the main shutoff valve andbackflow preventer shall be provided by the General Contractor's licensed plumbing Contractor per governing codes at the locationshown on the drawings. The minimum size and water pressure of the pressurized line will be as noted on the irrigation drawing.1.20TEMPORARY UTILITIESA.All temporary piping, wiring, meters, panels and other related appurtenances required between source of supply and point of useshall be provided by the Contractor and coordinated with the Owner's Representative. Existing utilities may be used with the writtenpermission of the owner.1.21CUTTING, PATCHING, TRENCHING AND DIGGINGA.The Contractor shall do all cutting, fitting, trenching or patching of their work that may be required to make its several parts cometogether as shown upon, or implied by, the drawings and specifications for the completed project.B.Digging and trenching operations shall be suspended when the soil moisture is above field capacity.1.22USE OF PREMISESA.The Contractor shall confine their apparatus; the storage of materials, and the operations of their workers to limits indicated by thelaw, ordinances, or permits and shall not unreasonably encumber the premises with their materials.B.Contractor parking, and material and equipment storage shall in areas approved by the Owner's Representative.1.23AS BUILT RECORD SET OF DRAWINGSA.Immediately upon the installation of any buried pipe or equipment, the Contractor shall indicate on the progress record drawings thelocations of said pipe or equipment. The progress record drawings shall be made available at any time for review by the Owner'sRepresentative.B.Before final acceptance of work, the Contractor shall provide an as built record set of drawings showing the irrigation system workas built. The drawings shall be transmitted to the Owner's Representative in paper format and as a pdf file of each document oncompact disk or flash drive. The drawings shall include all information shown on the original contract document and revised to reflectall changes in the work. The drawings shall include the following additional information1.All valves shall be numbered by station and corresponding numbers shall be shown on the as built record set of drawings.2.All main line pipe or irrigation equipment including sleeves, valves, controllers, irrigation wire runs which deviate from the mainlinelocation, backflow preventers, remote control valves, grounding rods, shut-off valves, rain sensors, wire splice locations, andquick coupling valves shall be located by two (2) measured dimensions, to the nearest one-half foot. Dimensions shall be givenfrom permanent objects such as buildings, sidewalks, curbs, walls, structures and driveways. All changes in direction and depth ofmain line pipe shall be noted exactly as installed. Dimensions for pipes shall be shown at no greater than a 50 ft. maximuminterval.3.As built record set of drawings shall be signed and dated by the Contractor attesting to and certifying the accuracy of the as builtrecord set of drawings. As built record set of drawings shall have "As Built Record Set of Drawings”, companyname, address, phone number and the name of the person who created the drawing and the contact name (if different).C.The Owner shall make the original contract drawing files available to the Contractor.1.24CONTROLLER CHARTS:A.Provide one controller chart for each automatic controller installed.1.On the inside surface of the cover of each automatic controller, prepare and mount a color-coded chart showing the valves, mainline, and systems serviced by that particular controller. All valves shall be numbered to match the operation schedule and thedrawings. Only those areas controlled by that controller shall be shown. This chart shall be a plot plan, entire or partial, showingbuilding, walks, roads and walls. The plan, reduced as necessary and legible in all details, shall be made to a size that will fit intothe controller cover. This print shall be approved by the Owner's Representative and shall be protected in laminated in a plasticcover and be secured to the inside back of the controller cabinet door.2.The controller chart shall be completed and approved prior to acceptance of the work.1.25TESTINGA.Provide all required system testing with written reports as described in part 3.1.26OPERATION AND MAINTENANCE MANUALS AND GUARANTEESA.Prepare and deliver to the Owner's Representative within ten calendar days prior to completion of construction, two 3-ring hardcover binders containing the following information:1.Index sheet stating Contractor's address and telephone number, list of equipment with name and addresses of localmanufacturers' representatives.2.Catalog and parts sheets on all material and equipment.3.Guarantee statement. The start of the guarantee period shall be the date the irrigation system is accepted by the Owner.4.Complete operating and maintenance instruction for all major equipment.5.Irrigation product manufacturers warrantees.B.In addition to the above-mentioned maintenance manuals, provide the Owner's maintenance personnel with instructions formaintaining major equipment and show evidence in writing to the Owner's Representative at the conclusion of the project that thishas been rendered.PART 2 PRODUCTS2.1MATERIALS GENERALA.All materials shall be of standard, approved and first grade quality and shall be new and in perfect condition when installed andaccepted.B.See the parts schedule on the drawings for specific components and manufacturers. The use of a manufacturer's name and modelor catalog number is for the purpose of establishing the standard of quality and configuration desired only. Other manufacturer'sequipment may be submitted for approval with written approval by the Owner's Representative. Substituted equipment shall notsubstantially alter the operations of the system.C.Approval of any items or substitutions indicates only that the product(s) apparently meet the requirements of the drawings andspecifications on the basis of the information or samples submitted. The Contractor shall be responsible for the performance ofsubstituted items. If the substitution proves to be unsatisfactory or not compatible with other parts of the system, the Contractor shallreplace said items with the originally specified items, including all necessary work and modifications to replace the items, at no costto the owner.2.2RECLAIMED WATER SYSTEM DESIGNATIONA.Where irrigation systems use reclaimed water, all products including valve boxes, lateral and main line pipe, etc. where applicableand/or required by local code shall have the reclaimed water purple color designation.2.3PIPING MATERIALA.Individual types of pipe and fittings supplied are to be of compatible manufacturer unless otherwise approved. Pipe sizes shown arenominal inside diameter unless otherwise noted.B.Plastic pipe:1.All pipe shall be free of blisters, internal striations, cracks, or any other defects or imperfections. The pipe shall be continuouslyand permanently marked with the following information: manufacturer's name or trade mark, size, class and type of pipe pressurerating, quality control identifications, date of extrusion, and National Sanitation Foundation (NSF) rating.2.Pressure main line for piping upstream of remote control valves and quick coupling valves:a.Pipe smaller than 2 inch diameter shall be plastic pipe for use with solvent weld or threaded fittings. Shall be manufacturedrigid virgin polyvinyl chloride (PVC) 1220, Type 1, Grade 2 conforming to ASTM D 1785, designated as Schedule 40.b.Pipe 2 - 3 inch diameter shall be manufactured rigid virgin polyvinyl chloride (PVC), Type 1, Grade 2 conforming to ASTM D1785, designated as bell gasket Class 315.c.Pipe larger than 3 inch diameter shall be manufactured rigid virgin polyvinyl chloride (PVC), Type 1, Grade 2 conforming toASTM D 1785, designated as bell gasket Class 200 PVC.3.Non_pressure lateral line for piping downstream of remote control valves: plastic pipe for use with solvent weld or threadedfittings. Shall be manufactured rigid virgin polyvinyl chloride PVC 1220 (type 1, grade 2) conforming to ASTM d 1785, designatedas Class 200, 3/4 minimum size.C.Galvanized pipe shall be used for above ground connections to, backflow prevention device assemblies, hose bibs, and boosterpumps and as shown on the plans and details.1.Pipe shall be hot dip galvanized continuous welded, seamless, Schedule 40 conforming to applicable current ASTM standards.2.4FITTINGS AND CONNECTIONS:A.Polyvinyl chloride pipe fittings and connections: Type II, Grade 1, Schedule 40, high impact molded fittings, manufactured from virgincompounds as specified for piping tapered socket or molded thread type, suitable for either solvent weld or screwed connections.Machine threaded fittings and plastic saddle and flange fittings are not acceptable. Furnish fittings permanently marked withfollowing information: nominal pipe size, type and schedule of material, and National Sanitation Foundation (NSF) seal of approval.PVC fittings shall conform to ASTM D2464 and D2466.B.Brass pipe fittings, unions and connections: standard 125 pound class 85% red brass fittings and connections, IPS threaded.C.PVC Schedule 80 threaded risers and nipples: Type I, grade 1, Schedule 80, high impact molded, manufactured from virgincompounds as specified for piping and conforming to ASTM D-2464. Threaded ends shall be molded threads only. Machinedthreads are not acceptable.D.Galvanized pipe fittings shall be galvanized malleable iron ground joint Schedule 40 conforming to applicable current ASTMstandards.2.5SOLVENT CEMENTS AND THREAD LUBRICANTA.Solvent cements shall comply with ASTM D2564. Socket joints shall be made per recommended procedures for joining PVC plasticpipe and fittings with PVC solvent cement and primer by the pipe and fitting manufacturer and procedures outlined in the appendixof ASTM D2564.B.Thread lubricant shall be Teflon ribbon-type, or approved equal, suitable for threaded installations as per manufacturer'srecommendations.C. Pipe Joint Compound (Pipe dope) shall be used on all galvanized threaded connections. Pipe Joint Compound is a white colored,non-separating thread sealant compound designed to seal threaded connections against leakage due to internal pressure. It shallcontain PTFE (Polytetrafluoroethylene) to permit a tighter assembly with lower torque, secure permanent sealing of all threadedconnections and allow for easy disassembly without stripping or damaging threads.2.6BACKFLOW PREVENTION DEVICESA.The backflow prevention device shall be certified to NSF/ANSI 372 shall be ASSE Listed 1013, rated to 180 degree F, and suppliedwith full port ball valves.B.The main body and access covers shall be low lead bronze (ASTM B 584)C.The seat ring and all internal polymers shall be NSF Listed Noryl and the seat disc elastomers shall be silicone.D.Backflow Preventer shall be as indicated on the drawings.2.7PRESSURE REGULATORA.Pressure regulator shall certified to NSF/ANSI 372, consisting of low lead bronze body bell housing, a separate access cap shall bethreaded to the body and shall not require the use of ferrous screws.B.The main valve body shall be cast bronze (ASTM B 584).C.The access covers shall be bronze (ASTM B 584 or Brass ASTM B 16)D.The assembly shall be of the balanced piston design and shall reduce the pressure in both flow and no flow conditions.E.Pressure regulator shall be as indicated on the drawings.2.7. WYE STRAINERA. Strainer shall conform to MIL -S-16293, and be ANSI 3rd party certified to comply with the states lead plumbing law 0.25%maximum weighted average lead content.B. The main body shall be low lead bronze (ASTM B 584)C. The access covers shall be yellow brass or cast bronze (ASTM B 16 or ASTM B 584)D. Strainer screen shall be 300 series stainless steel available in 20, 40, 60, 80, or 100 mesh.F.Wye strainer shall be as indicated on the plans.G.2.8BACKFLOW PREVENTER CAGE & FROST BLANKETH.A heavy-duty steel mesh cage with rust proof finish. The caging shall be sized to allow space for the entire piping assemblyassociated with the Backflow Preventer unit, and all associated equipment.I.The cage shall include the manufacturers' standard tamper proof locking mechanism.J.Provide a concrete base as detailed on the drawings.K.Backflow Preventer Cage type, manufacturer and color shall be as indicated on the plans.L.A Frost Blanket, manufacturer and color shall be as indicated on the plans.2.9BOOSTER PUMP ( where applicable)A.Booster pump shall be housed in a sturdy, locking, weather-resistant case, furnished for maximum exterior protection.B.Booster pump shall be as indicated on the drawings. .2.10BALL VALVESA.Ball valves for 3/4 inch through 2 - 1/2 inch shall be of PVC, block, tru-union design with EDPDM seals and o-ring.B.Ball valves for 3 inch and larger shall be gate design and shall be iron body, brass or bronze mounted AWWA gate valves, and shallhave a clear waterway equal to the full nominal diameter of the valve, and shall be rubber gasket, flanged or mechanical joint only,and shall be able to withstand a continuous working pressure of 150 PSI. Valve shall be equipped with a square-operating nut.C.All ball valves located in a valve manifold shall be the same size as the main line (1-1/2 inch size minimum). Provide pipe-reducingadapters down stream of valves, as required. All ball valves in line shall be the same size as the pipe.D.Ball valves shall be as indicated on the drawings.2.11CHECK VALVESA.Swing check valves 2 inch and smaller shall be 200 lbs., W.O.G., bronze construction with replaceable composition, neoprene orrubber disc and shall meet or exceed federal specification WW-V-5ld, class a, type iv.B.Anti_drain valves shall be of heavy-duty virgin PVC construction with female iron pipe thread inlet and outlet. Internal parts shall bestainless steel and neoprene. Anti-drain valves shall be field adjustable against draw out from 5 to 40 feet of head.C.Check valves shall be as indicated on the drawings.2.12REMOTE CONTROL VALVESA.Remote control valves shall be electrically operated, single seat, normally closed configuration, equipped with flow controladjustment and capability for manual operation.B.Valves shall be actuated by a normally closed low wattage solenoid using 24 volts, 50/60 cycle solenoid power requirement.Solenoid shall be epoxy encased. A union shall be installed on the discharge end.C.Remote control valves shall be wired to controller in same numerical sequence as indicated on drawings.D.Remote control valves shall be as indicated on the drawings.2.13MASTER CONTROL VALVESE.Master Control Valve shall be compatible with the irrigation controller.F.Master control valves shall be as indicated on the drawings.2.14FLOW SENSORA.Flow sensor shall be compatible with the irrigation controller.B.Flow sensor shall be as indicated on the drawings.2.15HYDROMETERC.Hydrometer shall be compatible with the irrigation controller.D.Hydrometer shall be as indicated on the drawings.2.16QUICK COUPLER VALVESA.Quick coupler valves shall be a one or two piece, heavy-duty brass construction with a working pressure of 150 PSI with a built inflow control and a self_closing valve.B.Quick coupler shall be equipped with locking red brass cap covered with durable yellow thermo-plastic rubber cover. Key size shallbe compatible with quick coupler and of same manufacturer.C.Quick coupler valves shall be as indicated on the drawings.2.17SPRINKLER HEADSD.All sprinkler heads shall have check valves installed.E.All sprinkler heads shall be as indicated on the drawings.F.Riser nipples for all sprinkler heads shall be the same size as the riser opening in the sprinkler body and fabricated as shown on thedrawings.2.18AUTOMATIC CONTROLLERA.Controller shall be housed in a sturdy, locking, weather_resistant case, furnished for maximum exterior protection.B.Controller shall be equipped with evapo-transpiration (ET) sensor, which adjusts the controller programming based on local climaticconditions. The sensor shall also have a rain sensing shut-off switch, wind sensing shut off switch, and freeze sensing shut-off ofswitch.1.If a moisture sensor is used in lieu of an evapo-transpiration sensor an additional sensor, which has a rain-sensing shut-off switch,wind sensing shut-off switch, and freeze sensing shut-off switch shall be provided.C.Automatic controller shall be as indicated on the drawings.2.19CONTROLLER DECODERSD.All decoders shall be per the controller manufacturer's specifications.E.Decoder model number shall be as shown on the drawings.2.20ELECTRICAL CONTROL WIRINGA.Low voltage1.The electrical control wire shall be direct burial type UF, no. 14 AWG, solid, single conductor, copper wire UL approved or larger,if required to operate system as designed.2.For 2-Wire controllers all irrigation wire for the controller, flow sensor, master valve, hydrometer, remote control valves andmoisture sensors shall be per the controller manufacturer's specifications and recommendations.3.Color code wires to each valve. Common wire shall be white.4.If multiple controllers are being utilized, and wire paths of different controllers cross each other, both common and control wiresfrom each controller to be of different colors.5.Control wire splices: Splices are when required shall be placed in splice boxes.6.Wire connections shall be per the controller manufacturer's specifications and recommendations.B.High voltage1.Shall be of type as required by local codes and ordinances.2.Shall be of proper size to accommodate needs of equipment it is to serve.2.21VALVE BOXES AND MATERIALSA.Valve boxes: valve boxes shall be constructed of ABS (acrylonitrile butadiene styrene) plastic, green in color, with rigid base andsides and shall be supplied with bolt lock cover secured with stainless steel bolts. Cover shall be identified as shown on drawings.Provide box extensions as required.1.Master valves, flow sensors, remote control irrigation valves, gate valves, and ball valves 3 inch or less in size shall use a 14 inchx 19 inch x 12 inch rectangular box.2. Quick coupler valves, wire splices, and grounding rods shall use a 10 inch circular box.2.22CONCRETE THRUST BLOCKSA.Concrete thrust blocks shall be sized per the pipe manufactures requirement or as indicated on the drawings.2.23VALVE IDENTIFICATION TAGSA. Valve Identification Tags shall be 2.25 inch x 2.65 inch polyurethane. Color: potable water; yellow / Non-potable water; purple.Tags shall be permanently attached to each remote control valve with tamper proof seals as indicated on the drawings.2.24EQUIPMENT TO BE FURNISHED TO OWNERA.Two (2) sets of keys for each automatic controller.B.Two (2) 48 inch tee wrenches for operating the gate valves.C.Three (3) sets of special tools required for removing, disassembling and adjusting each type of sprinkler and valve supplied on thisproject.D.Five (5) Extra sprinkler heads, nozzles, shrub adapters, nozzle filter screens, for each type used on the project.E.Two (2) quick coupler keys to match manufacturer type of quick coupler.2.25INCIDENTAL MATERIALS AND EQUIPMENTA.Furnish all materials and equipment not specified above, but which are necessary for completion of the work as intended.2.26MAIN LINE LOCATOR TAPEA.3 - inch wide plastic detectable locator tape.2.27MAIN LINE AND LATERAL LINE BEDDING SANDA.Sand shall consist of natural or manufactured granular material, free of organic material, mica, loam, clay or other substances notsuitable for the intended purpose.B.Sand shall be masonry sand ASTM C 144 or coarse concrete sand, ASTM C 33.MARKET READY IMPROVEMENTS forTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSSTATEOFCALI
FOR
NIA
LICEN
SE
D
L
ANDSCAPEARCHITECTSignatureRenewal Date9.30.2021Date07.17.2020TS07/10/20202017.150NO.DATEDESCRIPTIONPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date07.17.2020PLANNING RE- SUBMITTAL12.10.2020
IRRIGATION NOTESL3.52.24EQUIPMENT TO BE FURNISHED TO OWNERA.Two (2) sets of keys for each automatic controller.B.Two (2) 48 inch tee wrenches for operating the gate valves.C.Three (3) sets of special tools required for removing, disassembling and adjusting each type ofsprinkler and valve supplied on this project.D.Five (5) Extra sprinkler heads, nozzles, shrub adapters, nozzle filter screens, for each type used onthe project.E.Two (2) quick coupler keys to match manufacturer type of quick coupler.2.25INCIDENTAL MATERIALS AND EQUIPMENTA.Furnish all materials and equipment not specified above, but which are necessary for completion ofthe work as intended.2.26MAIN LINE LOCATOR TAPEA.3 - inch wide plastic detectable locator tape.2.27MAIN LINE AND LATERAL LINE BEDDING SANDA.Sand shall consist of natural or manufactured granular material, free of organic material, mica, loam,clay or other substances not suitable for the intended purpose.B.Sand shall be masonry sand ASTM C 144 or coarse concrete sand, ASTM C 33.PART 3 EXECUTION3.1GENERAL REQUIREMENTSA.Code requirements shall be those of state and municipal codes and regulations locally governing thiswork, providing that any requirements of the drawings and specifications, not conflicting therewith, butexceeding the code requirements, shall govern unless written permission to the contrary is granted bythe Owner's Representative.B.Extreme care shall be exercised at all times by the Contractor in excavating and working in the projectarea due to existing utilities and irrigation systems to remain. Contractor shall be fully responsible forexpenses incurred in the repair of damages caused by their operation.1.The Contractor is responsible for identifying and maintaining existing irrigation main lines thatsupply water to areas on the site as noted on the drawings and outside of the proposed limit ofwork. The Contractor shall relocate or replace existing irrigation main line piping as required toprovide a continuous supply of water to all areas of existing irrigation on site.a.Providing continuous water supply shall include hand watering and or the use of watering trucksto provide adequate water.C.Plan locations of backflow preventers, valves, controllers, irrigation lines, sleeves, spray heads andother equipment are diagrammatic and indicate the spacing and relative locations of all installations.Final site conditions and existing and proposed plantings shall determine final locations and adjustedas necessary and as directed to meet existing and proposed conditions and obtain complete watercoverage. Minor changes in locations of the above from locations shown shall be made as necessaryto avoid existing and proposed trees, piping, utilities, structures, etc. at the Contractor's expense orwhen directed by the Owner's Representative.1.The Contractor shall be held responsible for relocation of any items without first obtaining theOwner's Representative's approval. The Contractor shall remove and relocate such items at theirexpense if so directed by the Owner's Representative.D.Prior to any work the Contractor shall stake out locations of all pipe, valves, equipment and irrigationheads and emitters using an approved staking method and maintain the staking of the approvedlayout in accordance with the drawings and any required modifications. Verify all horizontal andvertical site dimensions prior to staking of heads. Do not exceed spacing shown on drawings for anygiven area. If such modified spacing demand additional or less material than shown on the drawings,notify the Owner's Representative before beginning any work in the adjacent area.E.Stub out main line at all end runs and as shown on drawings. Stub out wires for future connectionwhere indicated on plan and as directed.F.Point of connection shall be approximately as shown on drawings. Connect new underground pipingand valves and provide all flanges, adapters or other necessary fittings for connection.G.Permission to shut off any existing in-use water line must be obtained 48 hours in advance, in writingfrom the Owner. The Contractor shall receive instructions from the Owner's Representative as to theexact length of time of each shut-off.H.No fittings shall be installed on pipe underneath pavement or walls.I.Prior to starting any work, Contractor shall obtain a reading of existing static water pressure (no flowcondition) at the designated point of connection and immediately submit written verification of pressurewith date and time of recording to Owner's Representative.3.2TRENCHING, DIRECTIONAL BORING AND SLEEVINGA.Perform all trenching, directional boring, sleeving and excavations as required for the installation ofthe work included under this section, including shoring of earth banks to prevent cave_ins.B.The Contractor may directional bore lines where it is practical or where required on the plans.1.Extend the bore 1' past the edge of pavement unless noted differently on the plans2.Cap ends of each bore and locate ends at finished grade using metal stakes.3.All boring and sleeving shall have detectable locator tape placed at the ends of the pipe.C.Make trenches for mains, laterals and control wiring straight and true to grade and free of protrudingstones, roots or other material that would prevent proper bedding of pipe or wire.D.Excavate trenches wide enough to allow a minimum of 4 - inch between parallel pipelines and 8 inchfrom lines of other trades. Maintain 3 - inch vertical clearance between irrigation lines. Minimumtransverse angle is 45 degrees. All pipes shall be able to be serviced or replaced without disturbingthe other pipes.E.Trenches for pipelines shall be made of sufficient depth to provide the minimum cover from finishedgrade as follows:4.Pressure main line: 18 inches below finish grade and 24-30 inches below paved areas in Schedule40 PVC sleeves.5.Reclaimed water constant pressure main lines shall cross at least twelve (12) inches below potablewater lines.a.If a constant pressure reclaimed water main line must be installed above a potable water line orless than twelve (12) inches below a potable water line, then reclaimed water line shall beinstalled within an approved protective sleeve. The sleeve shall extend ten (10) feet from eachside of the center of the potable line, for a total of twenty (20) feet. The sleeve shall becolor-coded (purple) for use with reclaimed water.3.Lateral lines: 12 inches below finish grade and 18 inches below paved areas in Schedule 40 PVCsleeves.4.Control wiring: to the side of pressure main line and 24 inches below paved areas in Schedule 40PVC sleeves.F.On new on-site systems (post-meter), the required horizontal separation between potable water lines,reclaimed water constant pressure main lines and sewer lines shall be a minimum of four (4) feetapart as directed by the project engineer and/ or regulatory agency. Measurements shall be betweenfacing surfaces, not pipe centerlines.G.When trenching through areas of imported or modified soil, deposit imported or modified soils on oneside of trench and subsoil on opposite side.H.Backfill the trench per the requirements in paragraphs “Backfilling and Compacting” below.3.3PIPE INSTALLATIONA.General Pipe Installation1.Exercise caution in handling, loading and storing, of plastic pipe and fittings to avoid damage.a.The pipe and fittings shall be stored under cover until using, and shall be transported in avehicle with a bed long enough to allow the length of pipe to lay flat so as not to be subjected toundue bending or concentrated external load at any point.b.All pipe that has been dented or damaged shall be discarded unless such dent or damagedsection is cut out and pipe rejoined with a coupling.2.Trench depth shall be as specified above from the finish grade to the top of the pipe.3.Install a detectable pipe locator tape 6 to 8 inches above all main line pipes.B.Polyvinyl Chloride Pipe (PVC) Installation1.Under no circumstance is pipe to rest on concrete, rock, wood blocks, construction debris or similaritems.2.No water shall be permitted in the pipe until a period of at least 24 hours has elapsed for solventweld setting and curing.3.Install assemblies and pipe to conform to respective details and where shown diagrammatically ondrawings, using first class workmanship and best standard practices as approved. All fittings thatare necessary for proper connections such as swing joints, offsets, and reducing bushings that arenot shown on details shall be installed as necessary and directed as part of the work.4.Dielectric bushings shall be used in any connections of dissimilar metals.5.Gasketed plastic pipe: pipe-to-pipe joints or pipe to fittings shall be made in accordance withmanufacturer's specifications.6.Solvent weld or threaded plastic pipe:a.Installation of all pipe and fittings shall be in strict accordance with manufacturer'sspecifications.b.Pipe shall be cut using approved PVC pipe cutters only. Sawed joints are disallowed. All fieldcuts shall be beveled to remove burrs and excess before gluing.c.Welded joints shall be given a minimum of 15 minutes to set before moving or handling. Excesssolvent on the exterior of the joint shall be wiped clean immediately after assembly.d.Plastic to metal connections shall be made with plastic adapters and if necessary, short (notclose) brass threaded_nipples. Connection shall be made with two (2) wraps of Teflon tape andhand tightened plus one turn with a strap wrench.e.Snake pipe horizontally in trench to allow one (1) foot of expansion and contraction per 100 feetof straight run.f.Threaded pipe joints shall be made using Teflon tape. Solvent shall not be used with threadedjoints. Pipe shall be protected from tool damage during assembly. All damaged pipe shall beremoved and replaced. Take up threaded joints with light wrench pressure.g.No close nipples or risers are allowed. Cross connections in piping is disallowed.h.Center load pipe at 10 feet on center intervals with small amount of backfill to prevent archingand slipping under pressure. Other than this preliminary backfill all pipe joints, fittings andconnections are to remain uncovered until successful completion of hydrostatic testing andwritten approval of the testing report.i.Concrete thrust blocks shall be constructed behind all pipe fittings 1-1/2 inch diameter andlarger at all changes of direction of 45 degrees or more.C.Galvanized Pipe Installation1.All joints shall be threaded with pipe joint compound used on all threads.2.Dielectric bushings shall be used in any connections of dissimilar metals.3.4TRENCHING, DIRECTIONAL BORING, AND SLEEVING REVIEW:A.Upon completion and installation of all trenching, directional boring, and sleeving, all installed irrigationcontrol wiring, lines and fittings shall be visually observed by the Owner's Representative unlessotherwise authorized. Do not cover any wires, lines or fittings until they have been tested andobserved by the Owner's Representative.3.5FLUSHINGA.Openings in piping system during installation are to be capped or plugged to prevent dirt and debrisfrom entering pipe and equipment. Remove plugs when necessary to flush or complete system.B.After completion and prior to the installation of any terminal fittings, the entire pipeline system shall bethoroughly flushed to remove dirt, debris or other material.3.6HYDROSTATIC PRESSURE TESTINGA.After flushing, and the installation of valves the following tests shall be conducted in the sequencelisted below. The Contractor shall furnish all equipment; materials and labor necessary to perform thetests and all tests shall be conducted in the presence of the Owner's Representative.B.Water pressure tests shall be performed on all pressure main lines before any couplings, fittings,valves and the like are concealed.C.Immediately prior to testing, all irrigation lines shall be purged of all entrapped air or debris byadjusting control valves and installing temporary caps forcing water and debris to be discharged froma single outlet.D.Test all pressure main line at 150 PSI. For a minimum of four (4) hours with an allowable loss of 5 PSI.Pressure and gauges shall be read in PSI, and calibrated such that accurate determination of potentialpressure loss can be ascertained.E.Re_test as required until the system meets the requirements. Any leaks, which occur during testperiod, will be repaired immediately following the test. All pipe shall be re_tested until final writtenacceptance.F.The Contractor is responsible for proving documentation stating the weather conditions, date, the starttime and initial water pressure readings, the finish time and final water pressure readings and the typeof equipment used to perform the test. The documentation must be signed by a witness acceptable tothe Owner, verifying all of the above-mentioned conditions.G.Submit a written report of the pressure testing results with the other above required information to theOwner's Representative for approval.3.7BACKFLOW PREVENTER TESTINGA.The backflow preventer shall be tested according to procedures and results per the requirements ofthe Foundation for Cross-Connection Control and Hydraulic Research, University of SouthernCalifornia or American Water Works Association whichever is more stringent.B.Testing shall be performed by a Backflow Prevention Assembly Tester with a current certification fromthe American Backflow Preventer Association.3.8CONTROLLER AND BOOSTER PUMP TESTING AND CERTIFICATIONA.Controller and booster Pump shall be certified by a factory approved certified professional. Contactxxxxxxxx at xxx.xxx.xxxx.3.9BACKFILLING AND COMPACTINGA.Irrigation trenches shall be carefully backfilled with material approved for backfilling and free of rocksand debris one (1) inch in diameter and larger. When back filling trenches in areas of imported ormodified planting soil, replace any excavated subsoil at the bottom and the imported soil or modifiedplanting soil at the top of the trench.B.Backfill shall be compacted with approved equipment to the following densities1.Backfill under pavement and within 2 feet of the edge of pavement: Compact to 95% or greater ofmaximum dry density standard proctor.2.Backfill of subsoil under imported planting mixes or modified existing planting soil: Between 85 and90% of maximum dry density standard proctor.3.Backfill of imported planting mixes or modified existing planting soil: Compact to the requirementsof the adjacent planting mix or planting soil as specified in section “Planting Soil”.C.Finish grade of all trenches shall conform to adjacent grades without dips or other irregularities.Dispose of excess soil or debris off site at Contractor's expense.D.Any settling of backfill material during the maintenance or warranty period shall be repaired at theContractor's expense, including any replacement or repair of soil, lawn, and plant material or pavingsurface.3.10RESURFACING PAVING OVER TRENCHESA.Restore all surfaces and repair existing underground installations damaged or cut as a result of theexcavation to their original condition, satisfactory to the Owner's Representative.B.Trenches through paved areas shall be resurfaced with same materials quality and thickness asexisting material. Paving restoration shall be performed by the project paving Sub-contractor or anapproved Contractor skilled in paving work.C.The cost of all paving restoration work shall be the responsibility of the irrigation Contractor unless thetrenching thru the paving was, by previous agreement, part of the general project related construction.3.11INSTALLATION OF EQUIPMENTA.General:1.All equipment shall be installed to meet all installation requirements of the product manufacturer.In the event that the manufactures requirements cannot be implemented due to particular conditionat the site or with other parts of the design, obtain the Owner's Representative's writtenauthorization and approval for any modifications.2.Install all equipment at the approximately at the location(s) and as designated and detailed on thedrawings. Verify all locations with the Owner's Representative.3.Install all valves within a valve box of sufficient size to accommodate the installation and servicingof the equipment. Group valves together where practical and locate in shrub planting areas.4.All sprinkler irrigation systems that are using water from potable water systems shall requirebackflow prevention. All backflow prevention devices shall meet and be installed in accordancewith requirements set forth by local codes and the health department.B.Pressure regulator:1.Set regulator for required PSI per manufacturer's specifications.C.Check Valve:1.Install check valves approximately at the locations necessary to prevent low head run off.D.Remote control valves:1.Install one remote control valve per valve box.2.Remote control valve manifolds and quick coupler valves shall be separate allowing use of a quickcoupler with all remote control valves shut off.3.Install boxes no farther than 12 inches from edge of paving and perpendicular to edge of pavingand parallel to each other. Allow 12 inches clearance between adjacent valve boxes.E.Quick coupler valve:1.Install each quick coupler valve in its own valve box.2.Install thrust blocks on quick couplers.3.Place no closer than 12 inches to adjacent paving.4.Install 18 inches off set from main line.F.Sprinkler heads:1.All main lines and lateral lines, including risers, shall be flushed and pressure tested beforeinstalling sprinkler heads.2.Install specified sprinkler heads as shown in details at locations shown on the drawings. Adjustlayout for full coverage, spacing of heads shall not exceed the maximum spacing recommended bythe manufacturer.3.All sprinkler heads shall be set perpendicular to finish grade unless otherwise designated on thedrawings or details.G.Irrigation controllers:1.Remote control valves shall be connected to controller in numerical sequence as shown on thedrawings.2.Controller shall be tested with complete electrical connections. The Contractor shall be responsiblefor temporary power to the controller for operation and testing purposes.3.Connections to control wiring shall be made within the pedestal of the controller. All wire shallfollow the pressure main insofar as possible.4.Electrical wiring shall be in a rigid gray PVC plastic conduit from controller to electrical outlet. Theelectrical Contractor shall be responsible for installing all wiring to the controller, in order tocomplete this installation. A disconnect switch shall be included.H.Wiring:1.Low Voltagea.Control wiring between controller and electrical valves shall be installed in the same trench asthe main line where practical. The wire shall be bundled and secured to the lower quadrant ofthe trench at 10 foot intervals with plastic electrical tape.b.When the control wiring cannot be installed in the same main line trench it shall be installed aminimum of 18 inches below finish grade and a bright colored plastic ribbon with suitablemarkings shall be installed in the trench 6 inches below grade directly over the wire.c.An expansion loop shall be provided every 500 feet in a box and inside each valve box.Expansion loop shall be formed by wrapping wire at least eight (8) times around a ¾ inch pipeand withdrawing pipe.d.Provide one control wire to service each valve in system.e.Provide 03 common wire(s) per controller, or as needed.f.Run two (2) spare #14 - 1 wires from controller along entire main line to last electric remotecontrol valve on each and every leg of main line. Label spare wires at controller and wire stub tobe located in a box.g.All control wire splices not occurring at control valve shall be installed in a separate splice valvebox.h.Wire markers (sealed, 1 inch to 3 inch square) are to identify control wires at valves and atterminal strips of controller. At the terminal strip mark each wire clearly indicting valve circuitnumber.2.High Voltagea.All electrical work shall conform to local codes, ordinances and any authorities havingjurisdiction. All high voltage electrical work to be performed by licensed electrician.b.The Contractor shall provide 120-volt power connection to the automatic controller unless notedotherwise on drawings.I.Valve boxes:1.Install one valve box for each type of valve installed as per the details.2.Gravel sump shall be installed after compaction of all trenches. Final portion of gravel shall beplaced inside valve box after valve is backfilled and compacted.3.Permanently label valve number and or controller letter on top of valve box lid using a methodapproved by the Owners Representative.J.Tracer wire:1.Tracer wire shall be installed with non_metallic plastic irrigation main lines where controller wiresare not buried in the same trench as the main line.2.The tracer wire shall be placed on the bottom of the trench under the vertical projection of the pipewith spliced joints soldered and covered with insulation type tape.3.Tracer wire shall be of a color not used for valve wiring. Terminate wire in a valve box. Provideenough length of wire to make a loop and attach wire marker with the designation "tracer wire".K.Drip Installation:1.Clamp fittings with Oetiker clamps or approved equal when operating pressure exceeds specificdrip tubing fitting requirements.2.When installing drip tubing, install soil staples as listed below:a.Sandy Soil - One staple every three (3') feet and two (2) staples on each change of direction(tee, elbow, or cross).b.Loam Soil - One staple every four (4') feet and two (2) staples on each change of direction (tee,elbow, or cross).c.Clay Soil - One staple every five (5') feet and two (2) staples on each change of direction (tee,elbow, or cross).3.Cap or plug all openings as soon as lines have been installed to prevent the intrusion of materialsthat would obstruct the pipe. Leave in place until removal is necessary for completion ofinstallation.4.Thoroughly flush all water lines before installing valves and other hydrants.3.12ADJUSTMENT AND COVERAGE TESTA.Adjustment:1.The Contractor shall flush and adjust all sprinkler heads, valves and all other equipment toascertain that they function according to the manufacturer's data.2.Adjust all sprinkler heads not to overspray onto walks, roadways and buildings when undermaximum operating pressure and during times of normal prevailing winds.B.Coverage test:1.The Contractor shall perform the coverage test in the presence of the Owner's Representative afterall sprinkler heads have been installed, flushed and adjusted. Each section is tested todemonstrate uniform and adequate coverage of the planting areas serviced.2.Any systems that require adjustments for full and even coverage shall be done by the Contractorprior to final acceptance at the direction of the Owner's Representative at no additional cost.Adjustments may also include realignment of pipes, addition of extra heads, and changes in nozzletype or size.3.The Contractor at no additional cost shall immediately correct all unauthorized changes orimproper installation practices.4.The entire irrigation system shall be operating properly with written approval of the installation bythe Owner's representative prior to beginning any planting operations.3.13REPAIR OF PLANTING SOILA.Any areas of planting soil including imported or existing soils or modified planting soil which becomecompacted or disturbed or degraded as a result of the installation of the irrigation system shall berestored to the specified quality and compaction prior to beginning planting operations at no additionalexpense to the Owner. Restoration methods and depth of compaction remediation shall be approvedby the Owner's Representative.3.14CLEAN-UPA.During installation, keep the site free of trash, pavements reasonably clean and work area in anorderly condition at the end of each day. Remove trash and debris in containers from the site no lessthan once a week.a.Immediately clean up any spilled or tracked soil, fuel, oil, trash or debris deposited by theContractor from all surfaces within the project or on public right of ways and neighboringproperty.B.Once installation is complete, wash all soil from pavements and other structures.1.Make all repairs to grades ruts, and damage to the work or other work at the site.2.Remove and dispose of all excess soil, packaging, and other material brought to the site by theContractor.3.15PROTECTIONA.The Contractor shall protect installed irrigation work from damage due to operations by otherContractors or trespassers.1.Maintain protection during installation until Acceptance. Treat, repair or replace damaged workimmediately. The Owner's Representative shall determine when such treatment, replacement orrepair is satisfactory.3.16PRE-MAINTENANCE OBSERVATION:A.Once the entire system shall be completely installed and operational and all planting is installed, theOwner's Representative shall observe the system and prepare a written punch list indicating all itemsto be corrected and the beginning date of the maintenance period.B.The irrigation/landscape contractor is responsible for scheduling an irrigation audit prior to generalmaintenance taking effect. The irrigation auditor must be CLIA certified, in good standing and mustcomply with all Irrigation Associations methods and code of ethics.C.This is not final acceptance and does not relieve the Contractor from any of the responsibilities in thecontract documents.3.17GENERAL MAINTENANCE AND THE MAINTENANCE PERIODA.General maintenance shall begin immediately after installation of irrigation system. The generalmaintenance and the maintenance period shall include the following:1.On a weekly basis the Contractor shall keep the irrigation system in good running order and makeobservations on the entire system for proper operation and coverage. Repair and cleaning shall bedone to keep the system in full operation.2.Records of all timing changes to control valves from initial installation to time of final acceptanceshall be kept and turned over to the Owner's Representative at the time of final acceptance.3.During the last week of the maintenance period, provide equipment familiarization and instructionon the total operations of the system to the personnel who will assume responsibility for runningthe irrigation system.4.At the end of the maintenance period, turn over all operations logs, manuals, instructions,schedules, keys and any other equipment necessary for operation of the irrigation system to theOwner's Representative who will assume responsibility for the operations and maintenance of theirrigation system.B.The maintenance period for the irrigation system shall coincide with the maintenance period for thePlanting. (See specification section “Planting”3.18SUBSTANTIAL COMPLETION ACCEPTANCEA.Upon written notice from the Contractor, the Owners Representative shall review the work and make adetermination if the work is substantially complete.B.The date of substantial completion of the irrigation shall be the date when the Owner's Representativeaccepts that all work in Planting, Planting Soil, and Irrigation installation sections is complete.3.19FINAL ACCEPTANCE / SYSTEM MALFUNCTION CORRECTIONSA.At the end of the Plant Warrantee and Maintenance period, (See specification section “Planting”) theOwner's Representative shall inspect the irrigation work and establish that all provisions of theirrigation system are complete and the system is working correctly.1.Restore any soil settlement over trenches and other parts of the irrigation system.2.Replace, repair or reset any malfunctioning parts of the irrigation system.B.The Contractor shall show all corrections made from punch list. Any items deemed not acceptableshall be reworked and the maintenance period will be extended.C.The Contractor shall show evidence that the Owner's Representative has received all charts, records,drawings, and extra equipment as required before final acceptance.D.Failure to pass review: If the work fails to pass final review, any subsequent observations must berescheduled as per above. The cost to the Owner for additional observations will be charged to theContractor at the prevailing hourly rate of the reviewer.END OF SECTION 32 8400MARKET READY IMPROVEMENTS forTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSSTATEOFCALI
FO
R
NIA
LICEN
SE
D
L
ANDSCAPEARCHITECTSignatureRenewal Date9.30.2021Date07.17.2020TS07/10/20202017.150NO.DATEDESCRIPTIONPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date07.17.2020PLANNING RE- SUBMITTAL12.10.2020
WATER USE CALCULATIONSL3.6·Irrigation/Watering ResponsibilityoIt is the responsibility of the Maintenance Contractor to operate theirrigation system in an efficient manner and to minimize water waste.It is the Maintenance Contractor's responsibility to adjust the system toapply water in accordance with plant requirements based on weather,soil, and site conditions. The irrigation program shall be scheduled tominimize water waste through runoff, excessive irrigation run times,utilize CYCLE SOAK scheduling when applicable. It is the responsibilityof the Maintenance Contractor to operate the irrigation system basedon local municipal guidelines.·Irrigation Activationo Activate irrigation system in spring (or when weather permits). Charge mainline in February or March to check for leaks and/or malfunctioning valves.o Turn on backflow preventers, open gate valves and activate booster pumps if installed.o Set the irrigation controller to RUN MODE and verify that all programs are activated and set up to be run in Self Adjusted mode.o Site verification and adjustments. This includes turning on each zone, monitoring for leaks or malfunctioning parts, cutting grass away from sprinkler heads and adjusting sprinklers for proper arc and maximum efficiency.o Verify that drip irrigation is functional and that distribution tubing has not been cut or broken during non operational period.o Service, clean and adjust and weather sensor system. This is critical for ALL self adjusting controllers.o If applicable service irrigation booster pump, this need to be completed by the manufacturers certified technician.·Irrigation Monitoring/Landscape WateringoCheck the ET/Weather Based self adjusting system programming, FlowSensor and Master Valve operation and programming; adjust asrequired to ensure proper operation.oALL Backflow Prevention Devices are to be maintained as per Local cityor county codes.oAll turf areas shall be monitored to determine the need forsupplemental irrigation. Frequency and duration of each watering willbe dependent on local weather conditions. To determine the need forwatering, Landscape Maintenance Contractor shall use a soil probe toexamine the first 6-12” of the soil profile. If the soil is cool, damp andholds its shape, watering is not necessary. Plant material roots shouldbe encourage to root as deep as possible, this is accomplished by deeproot watering, longer irrigation run times and utilizing CYLCE SOAKmethod. Frequent shallow irrigation scheduling is ineffective and willonly promote shallow rooting and require excessive water waste.o Groundcover and shrub beds shall be watered using an automaticirrigation system. The entire groundcover/shrub bed shall be soaked toa depth to maximize healthy plant root growth. Irrigation run time tobe based on irrigation device precipitation rate (not flow rate) and plantmaterial irrigation demand. (Use WUCOLS reference for plant wateringneeds). In the event of establishing plants, or compromised soil profile,watering frequencies may be adjusted.oEstablish time settings and intervals of irrigation water application foreach valve of all irrigation zones. Make adjustments when necessary tocorrespond to variable watering requirements. Check for coverage andplugged emission/nozzle devices. Clean devices and adjust deviceswhile maintaining the system in proper working order.oALL automatic controllers will be programmed to apply water duringhours as permitted by local town, city or county ordinances.·Irrigation System RepairoCleaning and adjusting the sprinklers heads are the MaintenanceContractor's responsibility. Repair and/or replacement of anyvandalized or malfunctioning component beyond MaintenanceContractor's control is the responsibility of the Owner/Agent. Anydamage caused by Maintenance Contractor will be repaired byMaintenance Contractor at no cost to the Owner/Agent.o All irrigation repaired or replaced MUST be in accordance with theoriginal irrigation design, local city or county guidelines and mustprovide the maximum efficiency as possible so as NOT to waste water.oALL Drip systems are to be manually flushed a minimum one time peryear and filters to be cleaned on a regular basis.oAll damaged and repaired pipe MUST be flushed of all debris.Maintenance Contractor to guarantee full operational and efficientperformance of repaired systems.oRepairs to Backflow Prevention Devices must be conducted by a trainedcertified backflow technician.oIt is recommended that ALL irrigation maintenance and repair beperformed by California Licensed and/or Certified contractor. Notmaintaining irrigation systems in an efficient manner will result in plantand landscape degradation and additional maintenance costs.·Irrigation System WinterizationoWhere applicable, shut off and drain irrigation system(s) at the end ofthe irrigation season. Turn off all main supply valves, open all manualdrain valves, and bleed valves on backflow prevention devices. Performwinterization prior to November 1st.·Irrigation Start upo Flush all drip lines at flush points.o Remove and clean all filters and replace any damaged filters.o Check that all weathers sensors are functioning and replace batteries asneeded.IRRIGATION MAINTENANCEIRRIGATION SCHEDULEMWELO CALCULATIONSPRECIPITATION RATES & SOIL INTAKE RATESMARKET READY IMPROVEMENTS forTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSSTATEOFCALI
FOR
N
IA
LICENS
E
D
L
A
NDSCAPEARCHITECTSignatureRenewal Date9.30.2021Date07.17.2020TS07/10/20202017.150NO.DATEDESCRIPTIONPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date07.17.2020PLANNING RE- SUBMITTAL12.10.2020
HYDROZONE LAYOUTNORTHL3.7MARKET READY IMPROVEMENTS forTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSSTATEOFCALI
FO
R
N
IA
LICENS
E
D
L
ANDSCAPEARCHITECTSignatureRenewal Date9.30.2021Date07.17.2020TS07/10/20202017.150NO.DATEDESCRIPTIONPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date07.17.2020PLANNING RE- SUBMITTAL12.10.2020
03/27/2019 03:31:07 PM MARKET READY IMPROVEMENTS forTS12/10/20202017.150NO.DATEDESCRIPTIONSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date01.17.2021PLANNING RE- SUBMITTAL12.10.2020PLANNING RE- SUBMITTAL01.20.202121"=8'SITE MAPLINNET LANEAREA BAREA AAREA BAREA B2 #42 #4
03/27/2019 03:31:07 PM MARKET READY IMPROVEMENTS forTS12/10/20202017.150NO.DATEDESCRIPTIONSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date12.09.2020PLANNING RE- SUBMITTAL12.10.20201"=8'GIANT CHAIN FERNWOODWARDIA FIMBRIATAWESTERN SWORD FERNPOLYSTICHUM MUNITUMCORAL BELLSHEUCHERA 'MICRANTHA' MARTHARODERICKAUTUMN FERNDRYOPTERIS ERYTHROSORA 'BRILLIANCE'DEER FERNBLECHNUM SPICANTDEER GRASSMUHLENBERGIA RIGENSPINE MUHLYMUHLENBERGIA DUBIAATLAS FESCUEFESTUCA MAIREIMONKEYFLOWERMIMULUS 'JELLY BEAN RED'SMALL MAPLE TREEACER SPECIES SUITABLE FOR CONTAINERSPALMATUM / JAPONICUMEASTERN REDBUDCERCIS CANADENSISPRAIRIE GOLD ASPENPOPULUS TREMULOIDES 'NE ARB'TREES - SELECTION LISTUNDERSTORY - SELECTION LIST
03/27/2019 03:31:07 PM MARKET READY IMPROVEMENTS forTS12/10/20202017.150NO.DATEDESCRIPTIONSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date12.09.2020PLANNING RE- SUBMITTAL12.10.20201 #5
03/27/2019 03:31:07 PM MARKET READY IMPROVEMENTS forTS12/10/20202017.150NO.DATEDESCRIPTIONSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date12.09.2020PLANNING RE- SUBMITTAL12.10.2020B.VIEW FROM TRELLISA.VIEW TOWARDS WOOD SEATING & LOUNGE AND FENCEPROPOSED HARDSCAPE MATERIALS100% RECYCLEDSUSTAINABLE DECKING - MADE FROM AGRICULTURAL WASTEDECKING / SEATING / TABLECONCRETE - PAVING / WALLSTRELLISLONG LIFE SPAN / LOW MAINTENANCEPROVIDING WARMTH AND SHADECONCRETE WITH SAWCUT JOINTSWEATHERED COR-TENRESYSTA DECKINGINTEGRAL COLORSUSTAINABILITY - HIGH REFLECTIVITYNARRATIVE - ARIOSO POOL AND CLUBHOUSE -THE EXISTING EXTERIOR POOL, HOT TUB AND UPPER AMENITY AREA IS APPROXIMATELY 8925 SF ADJACENT THE EXISTING CLUBHOUSE.THE EXISTING AMENTITY AREA HAS LITTLE SHADE WITH AN UNDERUTILIZED UPPER TERRACE AND HARDSCAPE AREA. MOST OF THEUNDERSTORY HAS DIED, AND EXISTING TREES REMAIN. A SMALL WOOD TRELLIS ADJACENT THE BUILDING IS IN POOR CONDITION, HIGHMAINTENANCE AND DOES NOT PROVIDE SHADE TO NEEDED AREAS. THE POOL AND HOT TUB ARE IN GOOD CONDITION AND WILL REMAIN.THE PROPOSED DESIGN SEEKS TO MAXIMIZE USABILITY DURING THE DAYS AND EVENINGS WITH SMALL PRIVATE GATHERING SPACESTHROUGHOUT. THE DESIGN AESTHETIC REFLECTS A SIMPLE, ELEGANT AND COMFORTABLE SPACE THAT DOES NOT COMPETE WITH THEEXISTING ARCHITECTURE, BUT PROVIDES A FRESH UPDATE THAT COMPLEMENTS THE OVERALL SPACE WITH MORE USABLE INTIMATEAMENITY SPACES AND CONTEMPORARY FEELING FOR YOUNG FAMILIES.THE PROPOSED DESIGN INCLUDES TWO MAIN AMENITY AREAS, THE LOWER DECK AND AN UPPER TERRACE. AT THE LOWER DECK ALONG COR-TEN TRELLIS WITH INTEGRATED FENCE RUNS PARALLEL TO THE FENCE, PROVIDING SHADE ADJACENT THE POOL. THETRELLIS EXTENDS OVER THE SAUNA, PROVIDING A SPACE THAT CAN BE USED DURING HOT SUMMER DAYS WITH ADDED FEELING OFPROTECTION AT NIGHT. THE REMAINDER OF THE TRELLIS EXTENDS OVER A LARGE LOUNGE AREA, PROVIDING A USABLE SHADY SPACEFOR FAMILIES WITH CLEAR VISIBILITY TO THE POOL. WITH DECORATIVE LIGHTING ABOVE, THE TRELLIS PROVIDES A SCALING DEVICEFOR INTIMATE NIGHT TIME FAMILY GATHERING. A 100% RECYCLED WOOD DECKING COMPLIMENTS THE WARMTH OF THE TRELLIS,ADDING A FEELING OF QUALITY AND COMFORT TO THE LOWER DECK AREA.AN UPPER TERRACE AREA PROVIDES AN OVERLOOK WITH SMALLER NOOKS FRAMED BY PROPOSED PLANTING FOR GATHERING DURINGDAY AND EVENING. LIGHT DECIDUOUS TREES PROVIDE SHADE IN THE SUMMER, WITH FILTERED LIGHT FLOWING THROUGH THESTRUCTURED BRANCHES, PROVIDING A PLACE OF WARMTH AND COMFORT DURING THE WINTER. NATIVE AND LOW WATER USE PLANTSPROVIDE A BEAUTIFUL GARDEN SETTING. WOOD LOUNGES AND FIRE PITS FORM SEPARATE NOOKS EXTENDING A SENSE OF PRIVACY,WARMTH AND A FEELING OF NATURAL SOCIAL DISTANCING.THE UPPER TERRACE FORMS A SPATIALLY SEPARATE AREA FROM THE POOL, WHILE STILL PROVIDING CLEAR VISIBILITY INTO THE AREAFOR SAFETY. A SMALL COR-TEN TRELLIS IS PROPOSED OVER THE BBQ AND COMMUNITY TABLE AREA TO PROVIDE SHADE FROM HOTSUMMER SUN, WITH A USABLE BBQ AND FAMILY SPACE FOR DAY OR EVENING.THE MAIN OBJECTIVES OF THE DESIGN IS TO CREATE MORE VARIETY OF INTIMATE SPACES FOR SMALL GATHERING AND PROVIDEFILTERED SHADE FROM THE HOT SUMMER SUN. INTIMATE SPACES ARE FORMED AND SEPARATED THROUGH SCALING DEVICES,INCLUDING VEGETATION, SEATING, LEVEL CHANGES, PLANTER WALLS AND TRELLISES.SUSTAINABILITY:MATERIAL SELECTION:CONCRETE - HIGH REFLECTIVE VALUE TO DETER AN URBAN HEAT ISLANDCORTEN - LOW MAINTENANCE, LONG LIFE SPAN DURABLE SOLUTIONRESYSTA WOOD DECKING - 100% RECYCLED, MADE FROM AGRICULTURAL WASTENATIVE PLANTS:100% OF UNDERSTORY PLANTS ARE CA NATIVE OR LOW WATER USEBIO-DIVERSITY:DESIGN PROPOSES A MIX OF NATIVE PLANTS THAT PROVIDE HABITATFOR BUTTERFLIES AND BIRDSSITE RUNOFF:25% OF PROPOSED HARDSCAPE AREA (SEATING AND WALLS) IS ABLE TO BEDIRECTED INTO PROPOSED PLANTING AREA.C.TRELLIS AND FENCE BEYONDD.TRELLIS AND FENCE BEYOND1 #5,6
03/27/2019 03:31:07 PM MARKET READY IMPROVEMENTS forTS12/10/20202017.150NO.DATEDESCRIPTIONSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date12.09.2020PLANNING RE- SUBMITTAL12.10.20201"=8'
#3#2#1#4#5#6#7#8#9#10#11#12#13#15#14#17#18#19#20#1603/27/2019 03:31:07 PM MARKET READY IMPROVEMENTS forTS12/10/20202017.150NO.DATEDESCRIPTIONSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date12.09.2020PLANNING RE- SUBMITTAL12.10.20201"=8'#16#1#3#1#2#4#5#6#19#20#18#17#13#10#11#14#15#7#8#12#9#16
03/27/2019 03:31:07 PM MARKET READY IMPROVEMENTS forTS12/10/20202017.150NO.DATEDESCRIPTIONSCALEDATEDRAWN BYPROJECT ID299 BASSETT ST. SUITE 250
SAN JOSE, CA 95110
T:408.283.0100
ARCHITECTSALL DESIGNS, DRAWINGS AND WRITTENMATERIALS INDICATED HEREIN ARE THE WORKAND PROPERTY OF STUDIO G ARCHITECTS.THIS DOCUMENT MAY NOT BE DUPLICATED,REUSED OR DISCLOSED BY ANY METHODWITHOUT THE WRITTEN CONSENT OF STUDIO GARCHITECTS. ALL RIGHTS RESERVED.STAMPSHEET TITLESHEET NO.REVISIONSPROJECT ADDRESSTS STUDIO55 Sumner StreetSan Francisco, CA 94103www.tsstudio.orgPLANNING SUBMITTAL08.17.2020SignatureRenewal Date9.30.2021Date12.09.2020PLANNING RE- SUBMITTAL12.10.2020
19608 Pruneridge Avenue Arborist’s Assessment
and Report
August 10, 2020
August 10, 2020
TS Studio
978 Hayes Street
San Francisco, CA 94117
Summary
The plans indicate the pool area will be renovated to better accommodate the tenants. There will
be four trees removed and none are considered Heritage or Specimen species. Two of the four
trees to be removed are in poor condition and two fair while all four meet the criteria for removal
as stated in Justification - 14.18.180 Review, Determination and Findings. Subsections 1 and 3.
The replacement plan far exceeds the required four or five trees as indicated in 14.18.160 of the
municipal code and the selected species are appropriate for the desired function, location, and
future water use. Tree protection will focus on creating a barrier between the trees and
construction by protecting either the trunks or by placing fence along the planting beds.
Introduction
Background
The Arioso Apartments are planning on renovating the landscape around the pool area at the
complex. The renovation would include removing four trees. The City of Cupertino has
indicated they would like an arborist’s report regarding the existing trees and justification for the
removal.
Assignment
•Provide an arborist’s report including an assessment of the trees within the project area. The
assessment is to include the species, size (trunk diameter/circumference), condition (health,
structure, and form)..
•Photographs of the trees.
•Arborist report from a certified arborist with justification for removal
•provide justification from a certified arborist for the proposed replacement tree species.
•Provide tree protection requirements near trellis.
Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018
831.331.8982 - rick@monarcharborist.com Page of 1 21
19608 Pruneridge Avenue Arborist’s Assessment
and Report
August 10, 2020
Limits of Assignment
•The information in this report is limited to the condition of the trees during my inspection on
August 4, 2020 . No tree risk assessments were performed.
•The plans reviewed for this assignment were as follows provided by TS Studio dated July 10,
2020:
Purpose and Use
The report is intended to identify all the trees within the plan area that could be affected by a
project. The report is to be used by the property owners, owner’s agents, and the City of
Cupertino as a reference for existing tree and site conditions to help satisfy planning
requirements.
Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018
831.331.8982 - rick@monarcharborist.com Page of 2 21 03/27/2019 03:31:07 PMMARKET READY IMPROVEMENTS for
TS
07/10/2020
2017.150
NO.DATE DESCRIPTION
SCALE
DATE
DRAWN BY
PROJECT ID299 BASSETT ST. SUITE 250SAN JOSE, CA 95110T:408.283.0100ARCHITECTS
ALL DESIGNS, DRAWINGS AND WRITTEN
MATERIALS INDICATED HEREIN ARE THE WORK
AND PROPERTY OF STUDIO G ARCHITECTS.
THIS DOCUMENT MAY NOT BE DUPLICATED,
REUSED OR DISCLOSED BY ANY METHOD
WITHOUT THE WRITTEN CONSENT OF STUDIO G
ARCHITECTS. ALL RIGHTS RESERVED.
STAMP
SHEET TITLE
SHEET NO.
REVISIONS
PROJECT ADDRESS TS STUDIO55 Sumner StreetSan Francisco, CA 94103
www.tsstudio.org
50% CD07.09.2020
TRUE
NORTH N1"=8'
16'0'32'
L1.0 LANDSCAPE SITE PLAN
LD.1 LANDSCAPE DEMO PLAN
LD.2 TREE DISPOSITION PLAN
LD.3 TREE PROTECTION DETAILS
L1.1A LANDSCAPE LAYOUT PLAN
L1.2A LANDSCAPE MATERIAL PLAN
L1.3A LANDSCAPE FURNITURE PLAN
L1.4A LANDSCAPE LIGHTING PLAN
L2.1 LANDSCAPE GRADING PLAN
L3.0 IRRIGATION LAYOUT PLAN
L3.1 IRRIGATION DETAILS
L3.2 IRRIGATION DETAILS
L3.3 IRRIGATION NOTES
L3.4 IRRIGATION NOTES
LANDSCAPE SHEET LIST
L4.1 LANDSCAPE PLANTING PLAN
L5.1 LANDSCAPE SECTIONS
L6.1 LANDSCAPE DETAILS
L6.2 LANDSCAPE DETAILS
L6.3 LANDSCAPE DETAILS
L6.4 LANDSCAPE DETAILS
L6.5 LANDSCAPE DETAILS
L6.6 LANDSCAPE DETAILS
L6.7 LANDSCAPE DETAILS
L6.8 LANDSCAPE DETAILS
L6.9 LANDSCAPE DETAILS
19608 Pruneridge Avenue Arborist’s Assessment
and Report
August 10, 2020
Observations
Tree Inventory
The inventory contains the trees indicated in the plans located around the pool area and
immediate exterior. There are 20 trees composed of seven different species including the
following: 5 Brisbane box (Lophostemon confertus), 1 coast redwood (Sequoia sempervirens), 5
London plane (Platanus x hispanica), 4 pear (Pyrus calleryana), 1 queen palm (Syagrus
romanzoffiana), 1 red tip photinia (Photinia x fraseri), and 3 sweetgum (Liquidambar
styraciflua) (Chart 1). Pear tree #3 and coast redwood #19 are the two largest trees with trunk
diameters of 16 and 14 inches respectively. There are no Heritage Trees or Specimen Trees . 1 2
However all the trees are Protected Trees 14.18.050 (C) “Approved development trees(s)”
Heritage Tree: means any tree or grove of trees which, because of factors including, but not 1
limited to, its historic value, unique quality, girth, height or species, has been found by the
Planning Commission to have a special significance to the community.
Specimen Tree: means any class of tree specified in Section 14.18.050 of the city code.2
Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018
831.331.8982 - rick@monarcharborist.com Page of 3 21
Quantity
19608 Pruneridge Avenue Arborist’s Assessment
and Report
August 10, 2020
Discussion
Condition Rating
A tree’s condition is a determination of its overall health, structure, and form (ISA 2018). The
assessment considered all three characteristics for a combined condition rating.
•100% - Exceptional = Good health and structure with significant size, location or quality.
•61-80% - Good = Normal vigor, well-developed structure, function and aesthetics not
compromised with good longevity for the site.
•41-60 % - Fair = Reduced vigor, damage, dieback, or pest problems, at least one significant
structural problem or multiple moderate defects requiring treatment. Major asymmetry or
deviation from the species normal habit, function and aesthetics compromised.
•21-40% - Poor = Unhealthy and declining appearance with poor vigor, abnormal foliar color,
size or density with potential irreversible decline. One serious structural defect or multiple
significant defects that cannot be corrected and failure may occur at any time. Significant
asymmetry and compromised aesthetics and intended use.
•6-20% - Very Poor = Poor vigor and dying with little foliage in irreversible decline. Severe
defects with the likelihood of failure being probable or imminent. Aesthetically poor with
little or no function in the landscape.
•0-5% - Dead/Unstable = Dead or imminently ready to fail.
Most of the trees are in fair condition, seven good and three in poor shape (Appendix B)(Chart
2).
Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018
831.331.8982 - rick@monarcharborist.com Page of 4 21
Quantity
19608 Pruneridge Avenue Arborist’s Assessment
and Report
August 10, 2020
Expected Impact Level
Impact level defines how a tree may be affected by construction activity and proximity to the
tree, and is described as low, moderate, or high. The following scale defines the impact rating:
•Low = The construction activity will have little influence on the tree.
•Moderate = The construction may cause future health or structural problems, and steps must be
taken to protect the tree to reduce future problems.
•High = Tree structure and health will be compromised and removal is recommended, or other
actions must be taken for the tree to remain. The tree is located in the building envelope.
There are four trees that will be highly impacted and caused to be removed (Table 2).
Proposed Replacements and Species
The proposed planting accounts for the removal of the four trees including 14 of each of the
following species: (Acer palmatum or japonica) Japanese maples, (Cercis canadensis) redbud,
and (Populus tremulides) quaking aspen. The quantities exceed the replacement requirements
and the species selected will all conform with the desired function, location, and water use for
the site constraints.
Table 2: Trees Highly Impacted and Justification
Species Tree
I.D. #
Trunk
Diameter
Condition Required
Mitigation
Replacements
14.18.160
Justification - 14.18.180
Review, Determination and
Findings.
sweetgum
(Liquidambar
styraciflua)
17 7 Fair 24 inch box Subsection (3) tree is
sandwiched in a small planting
area directly adjacent to several
other specimens. Fruits cause
tripping hazards on walkway and
in pool area
red tip photinia
(Photinia x
fraseri)
18 2 Poor 24 inch box Subsection (1) tree is in poor
health with no remedy for
successful survival in its
environment.
coast redwood
(Sequoia
sempervirens)
19 14 Fair 2 - 24 inch box
or 1 - 36 inch
box
Subsection (3) Coast redwood
specimen is a planting bed with
inadequate space and high
watering requirements.
Brisbane box
(Lophostemon
confertus)
20 4 Poor 24 inch box Subsection (1) tree is failed
planting specimen that has never
established and now significantly
leans.
Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018
831.331.8982 - rick@monarcharborist.com Page of 5 21
19608 Pruneridge Avenue Arborist’s Assessment
and Report
August 10, 2020
Tree Protection
Tree protection focuses on avoiding damage to the roots, trunk, or scaffold branches from heavy
equipment. The tree protection zone (TPZ) is the defined area in which certain activities are
prohibited to minimize potential injury to the tree. The most current accepted method for
determining the TPZ radius is to use a formula based on species tolerance, tree age/vigor/health,
and trunk diameter (Matheny, N. and Clark, J. 1998) (Fite, K, and Smiley, E. T., 2016). Trunk
protection can be performed by placing vertical timbers against the stems avoiding mechanical
damage from equipment.
Tree #1-7 are located outside the fenced pool area and there is no need for additional fence while
trunk protection is recommended. Trees #8 through #11 are behind a retaining wall and fence is
not necessary in this location either. Trees #12 through #16 will have tree protection fence
around them which can be placed at the edge of hard-scape to enclose the planting beds. The
plans indicate there will be trunk protection placed on those retained with in the construction
area.
Conclusion
The plans indicate the pool area will be renovated to better accommodate the tenants. There will
be four trees removed and none are considered Heritage or Specimen species. Two of the four
trees to be removed are in poor condition and two fair while all four meet the criteria for removal
as stated in Justification - 14.18.180 Review, Determination and Findings. Subsections 1 and 3.
The replacement plans indicate forty-two additional trees will be planted which far exceeds the
required four or five as indicated in 14.18.160 of the municipal code. The species indicated for
replacement are appropriate for the desired function, location, and future water use. Tree
protection will focus on creating a barrier between the trees and construction by protecting either
the trunks or by placing fence along the planting beds to not disturb the soil surface underneath.
Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018
831.331.8982 - rick@monarcharborist.com Page of 6 21
19608 Pruneridge Avenue Arborist’s Assessment
and Report
August 10, 2020
Recommendations
1.Place tree numbers and tree protection fence locations and guidelines on the plans including
the grading, drainage, and utility plans.
2.Place trunk protection on trees #1 through #11. Place fence around trees #12 through #16 at
the edge of concrete.
3.All tree maintenance and care shall be performed by a qualified arborist with a C-61/D-49
California Contractors License. Tree maintenance and care shall be specified in writing
according to American National Standard for Tree Care Operations: Tree, Shrub and Other
Woody Plant Management: Standard Practices parts 1 through 10 and adhere to ANSI
Z133.1 safety standards and local regulations. All maintenance is to be performed according
to ISA Best Management Practices.
4.Refer to Appendix D for general tree protection guidelines including recommendations for
arborist assistance while working under trees, trenching, or excavation within a trees drip
line or designated TPZ/CRZ.
5.Provide a copy of this report to all contractors and project managers, including the architect,
civil engineer, and landscape designer or architect. It is the responsibility of the owner to
ensure all parties are familiar with this document.
6.Arrange a pre-construction meeting with the project arborist or landscape architect to verify
tree protection is in place, with the correct materials, and at the proper distances.
Construction and Post-Construction Phase
1.Monitor the health and structure of all trees for any changes in condition.
2.Perform any other mitigation measures to help ensure long term survival.
Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018
831.331.8982 - rick@monarcharborist.com Page of 7 21
19608 Pruneridge Avenue Arborist’s Assessment
and Report
August 10, 2020
Appendix A: Tree Locations and Protection
Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018
831.331.8982 - rick@monarcharborist.com Page of 8 21
#3#2
#1
#4
#5
#6
#7
#8
#9
#10
#11
#12
#13
#15
#14
#17
#18
#19
#20
#16
03/27/2019 03:31:07 PMMARKET READY IMPROVEMENTS for
TS
07/10/2020
2017.150
NO.DATE DESCRIPTION
SCALE
DATE
DRAWN BY
PROJECT ID299 BASSETT ST. SUITE 250SAN JOSE, CA 95110T:408.283.0100ARCHITECTS
ALL DESIGNS, DRAWINGS AND WRITTEN
MATERIALS INDICATED HEREIN ARE THE WORK
AND PROPERTY OF STUDIO G ARCHITECTS.
THIS DOCUMENT MAY NOT BE DUPLICATED,
REUSED OR DISCLOSED BY ANY METHOD
WITHOUT THE WRITTEN CONSENT OF STUDIO G
ARCHITECTS. ALL RIGHTS RESERVED.
STAMP
SHEET TITLE
SHEET NO.
REVISIONS
PROJECT ADDRESS
TS STUDIO
55 Sumner Street
San Francisco, CA 94103
www.tsstudio.org
50% CD07.09.2020
1"=8'
#16
#1
#3
#1#2
#4#5
#6
#18#19
#17#16
#13
#10#11
#14#15#7#8
#12
#9
19608 Pruneridge Avenue Arborist’s Assessment
and Report
August 10, 2020
Appendix B: Tree Table and Summary
Table 3: Inventory Summary
Tree Species I.D. #Trunk
Diameter
(in.)
~ Height
(ft.)
~ Canopy
Diameter
(ft.)
Condition Expected
Impact
sweetgum (Liquidambar
styraciflua)
1 8 25 25 Good Low/Retain
sweetgum (Liquidambar
styraciflua)
2 6 25 20 Good Low/Retain
pear (Pyrus calleryana)3 16 25 25 Fair Low/Retain
pear (Pyrus calleryana)4 8 25 25 Fair Low/Retain
pear (Pyrus calleryana)5 8 25 25 Fair Low/Retain
pear (Pyrus calleryana)6 9 25 25 Fair Low/Retain
queen palm (Syagrus
romanzoffiana)
7 8 20 15 Good Low/Retain
Brisbane box (Lophostemon
confertus)
8 5 20 15 Good Low/Retain
Brisbane box (Lophostemon
confertus)
9 5 20 15 Good Low/Retain
Brisbane box (Lophostemon
confertus)
10 5 20 15 Good Low/Retain
Brisbane box (Lophostemon
confertus)
11 5 20 15 Good Low/Retain
London plane (Platanus x
hispanica)
12 5 25 20 Fair Low/Retain
London plane (Platanus x
hispanica)
13 7 25 20 Fair Low/Retain
London plane (Platanus x
hispanica)
14 6 25 20 Poor Low/Retain
London plane (Platanus x
hispanica)
15 7 25 20 Fair Low/Retain
London plane (Platanus x
hispanica)
16 6 25 20 Fair Low/Retain
sweetgum (Liquidambar
styraciflua)
17 7 25 20 Fair High/
Remove
red tip photinia (Photinia x
fraseri)
18 2 8 6 Poor High/
Remove
Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018
831.331.8982 - rick@monarcharborist.com Page of 9 21
19608 Pruneridge Avenue Arborist’s Assessment
and Report
August 10, 2020
coast redwood (Sequoia
sempervirens)
19 14 35 20 Fair High/
Remove
Brisbane box (Lophostemon
confertus)
20 4 20 15 Poor High/
Remove
Tree Species I.D. #Trunk
Diameter
(in.)
~ Height
(ft.)
~ Canopy
Diameter
(ft.)
Condition Expected
Impact
Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018
831.331.8982 - rick@monarcharborist.com Page of 10 21
19608 Pruneridge Avenue Arborist’s Assessment
and Report
August 10, 2020
Appendix C: Photographs
C1: Photinia #18
Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018
831.331.8982 - rick@monarcharborist.com Page of 11 21