HomeMy WebLinkAboutAH Summary 05-14-2020
To: Mayor and City Council Members
Planning Commissioners
From: Benjamin Fu, Director of Community Development
Date: May 18, 2020
Subj: REPORT OF ADMINISTRATIVE HEARING DECISION MADE
May 14, 2020
Chapter 19.12.170 of the Cupertino Municipal code provides for
Appeal of decisions made at an Administrative Hearing
1. Application
ASA-2019-007, TR-2019-034, Tom Young (Spectrum Development/Courtyard By Marriott), 10605
N. Wolfe Rd
Description
Architectural and Site approval to allow facade modifications to an existing hotel (Courtyard by
Marriott) and a Tree Removal Permit to allow the removal and replacement of 15 development
trees
Action
The application was approved at the Administrative Hearing. The approval is effective May 14,
2020. The fourteen-calendar day appeal will expire on May 28, 2020.
Enclosures:
Administrative Hearing Report of May 14, 2020
Resolution No(s) 115 and 116
Plan set
OFFICE OF COMMUNITY DEVELOPMENT
CITY HALL
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3308 • FAX (408) 777-3333 • planning@cupertino.org
ADMINISTRATIVE HEARING STAFF REPORT
Meeting Date: May 14, 2020
Subject
Architectural and Site Approval Permit to allow for façade and landscape modifications
to the Courtyard by Marriott Hotel. Tree Removal Permit to allow for the removal and
replacement of 15 development trees. (Application No(s).: ASA-2019-007, TR-2019-034;
Applicant: Tom Young (Spectrum Development); Location: 10605 N. Wolfe Road.;
APN(s): 316-47-049)
Recommended Action
That the Hearing Officer adopt the draft resolutions (Attachments 1 and 2) to:
1. Find that the proposed actions are exempt from CEQA; and
2. Approve the Architectural and Site Approval Permit (ASA-2019-007) and the Tree
Removal Permit (TR-2019-034).
Discussion
Project Data
General Plan Designation Commercial/Residential
General Plan Special Area North Vallco Special Area
Zoning Designation P(Hotel)
Lot Size 154,624 sq. ft. (3.55 Acres)
Existing Proposed
Floor Area 79,406 sq. ft. (51.4%) No Change
Lot Coverage 35,223 sq. ft. (22.8%) 35,911 sq. ft. (23.2%)
Building Height 47’-6” No change
Project Consistency With:
General Plan Yes
Zoning Yes
Environmental Assessment Categorically Exempt per Section 15301 (Class 1) of
the California Environmental Quality Act (CEQA)
ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020
Page 2
Background
The property is located within the North Vallco Gateway in the North Vallco Special
Area. The North Vallco Special
Area is a major employment center
for Cupertino and is primarily
comprised of commercial and office
development – including
Courtyard by Marriott, Hilton
Garden, Cupertino Village, and
Apple Campus 2.
The project site is bounded by
Homestead Road to the north, N.
Wolfe Road to the east, HWY-280 to
the south, and Linnet Lane the west
(see Figure 1). The property is
located adjacent to the Hilton
Garden Inn and an approved (not
constructed yet) 185-room hotel to
the north, multi-family residential
(Arioso Apartments & The
Hamptons) to the north west and
east and single-family residential to
the west (off Linnet Lane). The 149-
room Courtyard by Marriott Hotel
was approved in 1986 by Planning
Commission with the approval of
U-1986-33.
Analysis
The applicant is requesting façade and landscape modifications to the existing Courtyard
by Marriott Hotel. The scope of work for the project is as follows:
Replacement of the arrival porte cochere;
Installation of architectural elements at the main and side entrances;
Exterior façade architectural material upgrades;
Demolition and replacement of the trash enclosure;
Installation of a new bicycle parking rack;
Removal and replacement of 15 development trees; and
Landscape enhancements.
Figure 1. Project site N. WOLFE ROAD LINNET LANE HILTON
GARDEN
INN
ARIOSO
APARTMENTS
ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020
Page 3
The scope of work does not include any increase to the existing room count, floor area,
or height and will therefore not result in an increased intensity of the existing use.
Exterior Building Modifications
The existing exterior materials for the Courtyard by Marriott consist of stucco walls with
a tile roof in a neutral color palette (see Figure 2). In line with Courtyard’s new
contemporary aesthetic, the applicant is requesting to modernize the building by
incorporating additional textures and finishes, including dry stone, faux wood (fiber
cement) wall paneling, and metal elements, along with a more contemporary color
scheme of white, greys, and brown.
As part of this project, the arrival porte cochere, main entrance and two entry stair towers
(on the east and west elevations) will be replaced with a more modern design feature
with a contemporary flat-roof, faux wood paneling, and metal accents (see Figures 3 & 4).
The porte cochere will be reduced in height by ~5.5’ (from 18’-4” to 12’10”) and the main
entrance by one foot (from 23’-10” to 22’10”). The proposed porte cochere will be slightly
larger in size and will cause the lot coverage to marginally increase from 35,223 sq. ft.
(22.8%) to 35,911 sq. ft. (23.2%). The North Vallco Special Area does not have a lot
coverage limitation imposed on the site.
In order to achieve the desired aesthetic, the applicant has proposed a minor increase in
the parapet height for the east and west entry stair towers, resulting in a total increase in
height of ~one-foot (from 32’-3” to ~33’-4”). However, the overall height of the building
Figure 2. Existing Conditions
ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020
Page 4
is not impacted since the existing roof forms of the bulk of the structure will remain
unchanged.
The proposed design was peer-reviewed by the City’s consulting architect who found
that the proposed changes are minor in scope and are architecturally harmonious with
the other portions of the building.
Figure 3 (above). Existing and Proposed
North Elevation
Figure 4 (below). Existing and Proposed West
Elevation
ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020
Page 5
The existing floor area and the number of guestrooms will not be impacted by the
proposed scope of work.
New lighting fixtures are also proposed as part of the scope of work. The applicant has
provided site photometrics, which indicate that the new light fixtures will not cause light
to spill-over onto adjacent residential or hotel properties.
Modifications to the existing signage are not part of th is scope of work and have been
reviewed and approved with a separate Building Permit (BLD-2020-0234).
Tree Removals/Replacements & Landscape Modifications
Per the Protected Trees Ordinance (Chapter 14.18) of the Cupertino Municipal Code
(CMC), all approved development trees (i.e. trees required to be planted or retained as
part of a development application, building permit, tree removal permit, or code
enforcement action) are considered “protected” and require approval of a tree removal
permit prior to removal. Replacements for the removed trees are required as part of the
tree removal permit.
The applicant is proposing to remove a total of 15 development trees along the exterior
of the building as part of the Tree Removal Permit (TR-2019-034). The arborist report
(Attachment 4) assesses the location, size, current condition, and overall health of the
trees proposed to be removed. These trees have generally been identified to be in good
condition, with trees #2 and #7 in fair condition, and trees #15 and #16 in critical condition.
Per the draft conditions of approval for TR-2010-034, all trees outlined in the arborist
report for removal are approved, with the exception of Tree #3, which shall remain on
site. The table below includes the trees proposed for removal (note: tree # corresponds
with the tree inventory provided with the arborist report).
TABLE 1 – TREES TO BE REMOVED AND REPLACEMENTS
Tree # DBH Tree Species Replacements
1 15 Camphor (Cinnamomum camphora) 2 – 24” box
2 6 Camphor (Cinnamomum camphora) 1 – 24” box
4 15 Southern Live Oak (Quercus virginiana) 2 – 24” box
5 15 Southern Live Oak (Quercus virginiana) 2 – 24” box
6 14 Southern Live Oak (Quercus virginiana) 2 – 24” box
7 14 Southern Live Oak (Quercus virginiana) 2 – 24” box
8 8 Japanese black pine (Pinus thunbergiana) 1 – 24” box
9 14 Australian Willow (Geijera parviflora) 2 – 24” box
10 12 Southern Live Oak (Quercus virginiana) 1 – 24” box
11 12 Southern Live Oak (Quercus virginiana) 1 – 24” box
ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020
Page 6
TABLE 1 – TREES TO BE REMOVED AND REPLACEMENTS
Tree # DBH Tree Species Replacements
12 12 Southern Live Oak (Quercus virginiana) 1 – 24” box
13 2 Eastern Redbud (Cercis canadensis) 1 – 24” box
14 3 Eastern Redbud (Cercis canadensis) 1 – 24” box
15 10 Coast Redwood (Sequoia sempervirens) 1 – 24” box
16 7 Coast Redwood (Sequoia sempervirens) 1 – 24” box
Total Replacements Required 21 – 24” box
The required replacement trees per the Protected Trees Ordinance are 21 24”-box trees.
The applicant exceeds the minimum number of replacement trees by proposing 27 trees
to be planted on site as follows:
12 24”-Box Crape Myrtle (Lagerstroemia Indica)
7 24”-Box Fruitless Olive (Olea Europaea)
6 24”-Box Streetspire Oak (Quercus Robur)
2 24”-Box Coast Redwood (Sequoia sempervirens)
These trees will be retained on the site as protected development trees. The arborist report
and proposed tree replacement species and locations were peer -reviewed by the City’s
Arborist who had no objections to the project. No trees along the westerly property line
adjoining the existing residential development are proposed for removal.
The applicant is also proposing to modify the existing landscape by removing and
replacing portions of the existing turf and planting area. The project is subject to a Full
Landscape Documentation Package per the Landscape Ordinance (Chapter 14.15) of the
CMC. The Landscape Ordinance requires the applicant to submit a Water -Efficient
Landscape Checklist, Water Budget Calculations, and finalized landscape, irrigation, and
grading design plan prior to building permit issuance.
Additional Site Modifications
The applicant is proposing to install a bicycle parking rack near the main entrance of the
hotel. The Parking Ordinance (Chapter 19.124) of the CMC requires one Class II bicycle
parking stall per every 20,000 sq. ft. of hotel floor area. The proposed bicycle rack
complies with the Parking Ordinance by providing 4 Class II bicycle parking stalls for the
79,406 sq. ft. hotel. The proposed plan will maintain the existing 140 vehicular parking
stalls required for the site.
The applicant is also proposing to replace the existing wood trash enclosure with a new
240 sq. ft. covered trash enclosure with a total height of 9’-9” in compliance with the City’s
requirements. The proposed trash enclosure will be located on the west building
ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020
Page 7
elevation and will incorporate the same exterior materials and paint color scheme
proposed throughout the primary building. The trash enclosure is considered an
accessory structure and is consistent with the Accessory Buildings/Structures Ordinance
(Chapter 19.100) of the CMC with regard to height and setbacks.
As part of the site modifications, the applicant has agreed to remove a portion of the
existing 6’ chain link fence along the east property line surrounding the pedestrian and
bicycle access pathway off N. Wolfe Road.
Interior modifications and minor tenant improvements have been reviewed and
approved by a separate Building Permit (B-2019-0205).
Environmental Review
This project is categorically exempt from the requirements of the California
Environmental Quality Act (CEQA) per Section 15301 – Existing Facilities.
Other Department/Agency Review
The City’s Building Division, Environmental Programs Division, Public Works
Department, and the Santa Clara County Fire Department have no objections to the
project.
Public Noticing & Community Outreach
The following table is a brief summary of the noticing for this project:
Notice of Public Hearing Agenda
Site Signage (at least 10 days prior to
hearing)
7 notices mailed to property owners
adjacent to the project site (at least 10
days prior to the hearing)
Posted on the City's official notice
bulletin board (five days prior to
hearing)
Posted on the City of Cupertino’s
Web site (five days prior to hearing)
No comments have been received at the time of production of this staff report.
Permit Streamlining Act
This project is subject to the Permit Streamlining Act (Government Code Section 65920 –
65964). The City has complied with the deadlines found in the Permit Streamlining Act.
Project Received: September 26, 2019; Deemed Incomplete: October 29, 2019
Revisions Received: January 5, 2020; Deemed Incomplete: February 5, 2020
Revisions Received: February 25, 2020; Deemed Complete: March 25, 2020
ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020
Page 8
Since this project is Categorically Exempt, the City has 60 days (until May 25, 2020) to
make a decision on the project.
Conclusion
Staff recommends approval of the Architectural and Site Approval Permit and the Tree
Removal Permit, as the proposed project will not create adverse impacts to the
surrounding area. Additionally, all the findings for approval of the proposed project,
consistent with Chapter 19.168 and 14.18 of the Cupertino Municipal Code, may be made
as reflected in the draft resolutions.
With respect to the Architectural and Site Approval Permit, the following findings may
be made:
1. The proposal, at the proposed location, will not be detrimental or injurious to property
or improvements in the vicinity, and will not be detrimental to the public health,
safety, general welfare, or convenience;
The proposal includes façade modifications to the existing Courtyard by Marriott hotel that
modernize the architectural style of the building. The exterior enhancements will incorporate
a flat-roof design, additional textures and finishes, including dry stone, faux wood (fiber
cement) wall paneling, and metal elements, and a more contemporary color scheme of white,
greys, and brown. The existing floor area, number of guestrooms, and total building height
will not be impacted by the proposed scope of work and the footprint of the existing hotel will
largely be retained with a minor increase in lot coverage. The materials used will have to
comply with building code and other state code standards for health and safety. Furthermore,
the project is located at an established hotel site in a residential and commercial district and is
surrounded by another hotel use, multi-family residential, and a small number of single-family
residential uses. Therefore, the façade modifications will not be detrimental or injurious to
property or improvements in the vicinity, and will not be detrimental to the publi c health,
safety, general welfare, or convenience.
2. The proposal is consistent with the purposes of Chapter 19.168, the General Plan any
specific plan, zoning ordinances, applicable planned development permit, conditional
use permits, variances, subdivision maps or other entitlements to use which regulate
the subject property including, but not limited to, adherence to the following specific
criteria:
a) Abrupt changes in building scale should be avoided. A gradual transition related
to height and bulk should be achieved between new and existing buildings.
The scale of the building will be maintained with no increase to the height. The façade
modifications will incorporate a flat-roof design at the main entrance, which will result in
a minor reduction in bulk. Overall, the hotel will maintain the same form as the existing
ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020
Page 9
structure with an enhanced contemporary design. Therefore, there will be no abrupt
changes in building scale related to height and bulk and no new buildings are being
proposed.
b) In order to preserve design harmony between new and existing buildings and in
order to preserve and enhance property values, the materials, textures and colors
of new building should harmonize with adjacent development by being consistent
or compatible with design and color schemes with the future character of the
neighborhoods and purposes of the zone in which they are situated. The location,
height and materials of walls, fencing, hedges and screen planting should
harmonize with adjacent development. Unsightly storage areas, utility
installations and unsightly elements of parking lots should be concealed. The
planting of ground cover or various types of pavements should be used to prevent
dust and erosion, and the unnecessary destruction of existing healthy trees should
be avoided. Lighting for development should be adequate to meet safety
requirements as specified by the engineering and building departments and
provide shielding to prevent spill-over light to adjoining property owners.
The façade modifications are harmonious with the existing building form and the proposed
upgrades to the existing materials and colors will not impact the future character of the
neighborhood. The new trash enclosure is located to the west of the building in an area not
visible from the public right-of-way and is designed to be compatible with the proposed
aesthetic of the hotel. The proposed tree removals are due to poor initial planting locations
that are not suitable for the continued maintenance of the trees. The proposed tree
replacements will improve the aesthetics of the site for its users. Additional landscaping is
being proposed to enhance existing landscaping at the site. The proposed new lighting
fixtures are designed in order to prevent spill-over light to adjoining properties.
c) The number, location, color, size, height, lighting and landscaping of outdoor
advertising signs and structures have been designed to minimize traffic hazard,
positively affect the general appearance of the neighborhood and harmonize with
adjacent development.
No signs are proposed as part of this project.
d) With respect to new projects within existing residential neighborhoods, new
development should be designed to protect residents from noise, traffic, light and
visually intrusive effects by use of buffering, setbacks, landscaping, walls and
other appropriate design measures.
This application is not a new development project.
ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020
Page 10
With respect to the Tree Removal Permit, the following findings may be made:
3. That the protected trees are a detriment to the subject property and cannot be
adequately supported according to good urban forestry practices due to the
overplanting or overcrowding of trees on the subject property.
The proposed tree removals are due to poor initial planting locations that are not suitable for
the continued maintenance of the trees. The proposed tree replacements will improve the
aesthetics of the site for its users. The City’s consulting arborist has reviewed the arborist
report and takes no exception to the proposal for removal.
Next Steps
The permit will become effective 14 calendar days from the date of the hearing. The
decision of the Administrative Hearing Officer is final, unless appealed within 14
calendar days from the date of the hearing. The applicant team may apply for building
and/or other permits with the City at the end of the appeal period (May 28, 2020 at
5:00pm).
This approval is valid until May 14, 2022. The applicant team may apply for a one-time
two-year extension before the approval expires.
Prepared by: Erika Poveda, Associate Planner
Reviewed and Approved for submission by: Piu Ghosh, Planning Manager
ATTACHMENTS
1. Draft Resolution for ASA-2019-007
2. Draft Resolution for TR-2019-034
3. Plan Set
4. Arborist Report
ASA-2019-007
CITY OF CUPERTINO
10300 Torre Avenue
Cupertino, California 95014
RESOLUTION NO. 115
OF THE ADMINISTRATIVE HEARING OFFICER OF THE CITY OF
CUPERTINO APPROVING AN ARCHITECTURAL AND SITE PERMIT
TO ALLOW FAÇADE AND LANDSCAPE MODIFICATIONS TO THE
EXISTING COURTYARD BY MARRIOTT HOTEL LOCATED
AT 10605 N. WOLFE ROAD
SECTION I: PROJECT DESCRIPTION
Application No.: ASA-2019-007
Applicant: Tom Young (Spectrum Development/Courtyard by Marriot Hotels)
Location: 10605 N. Wolfe Road (APN 316-47-049)
SECTION II: FINDINGS
WHEREAS, the City of Cupertino received an application for an Architectural and Site
Approval to consider allowing modifications to the exterior building materials and
landscaping for an existing hotel, as described in Section I. of this Resolution; and
WHEREAS, the necessary public notices have been given as required by the Procedural
Ordinance of the City of Cupertino, and the Administrative Hearing Officer has held at
least one public meeting with regard to the application; and
WHEREAS, pursuant to the provisions of the California Environmental Quality Act of
1970 (Public Resources Code section 21000 et seq.) (“CEQA”), together with the State
CEQA Guidelines (California Code of Regulations, Title 14, Section 15000 et seq.)
(hereinafter, "CEQA Guidelines"), the City staff has independently studied the proposed
Project and has determined that the Project is exempt from environmental review
pursuant to the categorical exemption in CEQA Guidelines section 15301 for the reasons
set forth in the staff report dated May 14, 2020 and incorporated herein; and
WHEREAS, the applicant has met the burden of proof required to support said
application; and
Resolution No. 115 ASA-2019-007 May 14, 2020
Page 2
WHEREAS, the Administrative Hearing Officer finds as follows with regard to this
application:
1. The proposal, at the proposed location, will not be detrimental or injurious to property
or improvements in the vicinity, and will not be detrimental to the public health,
safety, general welfare, or convenience;
The proposal includes façade modifications to the existing Courtyard by Marriott hotel that
modernize the architectural style of the building. The exterior enhancements will incorporate
a flat-roof design, additional textures and finishes, including dry stone, faux wood (fiber
cement) wall paneling, and metal elements, and a more contemporary color scheme of white,
greys, and brown. The existing floor area, number of guestrooms, and total building height
will not be impacted by the proposed scope of work and the footprint of the existing hotel will
largely be retained with a minor increase in lot coverage. The materials used will have to
comply with building code and other state code standards for health and safety. Furthermore,
the project is located at an established hotel site in a residential and commercial district and is
surrounded by another hotel use, multi-family residential, and a small number of single-family
residential uses. Therefore, the façade modifications will not be detrimental or injurious to
property or improvements in the vicinity, and will not be detrimental to the public health,
safety, general welfare, or convenience.
2. The proposal is consistent with the purposes of Chapter 19.168, the General Plan any
specific plan, zoning ordinances, applicable planned development permit, conditional
use permits, variances, subdivision maps or other entitlements to use which regulate
the subject property including, but not limited to, adherence to the following specific
criteria:
a) Abrupt changes in building scale should be avoided. A gradual transition related
to height and bulk should be achieved between new and existing buildings.
The scale of the building will be maintained with no increase to the height. The façade
modifications will incorporate a flat-roof design at the main entrance, which will result in
a minor reduction in bulk. Overall, the hotel will maintain the same form as the existing
structure with an enhanced contemporary design. Therefore, there will be no abrupt
changes in building scale related to height and bulk and no new buildings are being
proposed.
b) In order to preserve design harmony between new and existing buildings and in
order to preserve and enhance property values, the materials, textures and colors
of new building should harmonize with adjacent development by being consistent
or compatible with design and color schemes with the future character of the
Resolution No. 115 ASA-2019-007 May 14, 2020
Page 3
neighborhoods and purposes of the zone in which they are situated. The location,
height and materials of walls, fencing, hedges and screen planting should
harmonize with adjacent development. Unsightly storage areas, utility
installations and unsightly elements of parking lots should be concealed. The
planting of ground cover or various types of pavements should be used to prevent
dust and erosion, and the unnecessary destruction of existing healthy trees should
be avoided. Lighting for development should be adequate to meet safety
requirements as specified by the engineering and building departments and
provide shielding to prevent spill-over light to adjoining property owners.
The façade modifications are harmonious with the existing building form and the proposed
upgrades to the existing materials and colors will not impact the future character of the
neighborhood. The new trash enclosure is located to the west of the building in an area not
visible from the public right-of-way and is designed to be compatible with the proposed
aesthetic of the hotel. The proposed tree removals are due to poor initial planting locations
that are not suitable for the continued maintenance of the trees. The proposed tree
replacements will improve the aesthetics of the site for its users. Additional landscaping is
being proposed to enhance existing landscaping at the site. The proposed new lighting
fixtures are designed in order to prevent spill-over light to adjoining properties.
c) The number, location, color, size, height, lighting and landscaping of outdoor
advertising signs and structures have been designed to minimize traffic hazard,
positively affect the general appearance of the neighborhood and harmonize with
adjacent development.
No signs are proposed as part of this project.
d) With respect to new projects within existing residential neighborhoods, new
development should be designed to protect residents from noise, traffic, light and
visually intrusive effects by use of buffering, setbacks, landscaping, walls and
other appropriate design measures.
This application is not a new development project.
NOW, THEREFORE, BE IT RESOLVED:
That after careful consideration of the maps, facts, exhibits, testimony, staff’s report and
presentation, and other evidence submitted in this matter, subject to the conditions which
are enumerated in this Resolution beginning on PAGE 3 thereof,
The application for an Architectural and Site Approval, Application no. ASA-2019-007 is
hereby approved and that the subconclusions upon which the findings and conditions
specified in this resolution are based and contained in the Public Meeting record
Resolution No. 115 ASA-2019-007 May 14, 2020
Page 4
concerning Application no. ASA-2019-007 as set forth in the Minutes of the
Administrative Hearing Meeting of May 14, 2020 and are incorporated by reference as
though fully set forth herein.
SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT
DEPARTMENT
1. APPROVED EXHIBITS
Approval is based on the plan set drawn by Baskervill titled “Spectrum
Development Group, Courtyard by Marriott – San Jose Cupertino, CA – 10605 N.
Wolfe Rd., Cupertino, CA 95014 Exterior Reimage” consisting of 52 sheets labeled
T.001, A.001, A.002, A.010, A.011, A.012, A.013, A.110, A.111, A.114, A.201, A.202,
A.203, A.204, A.211, A.212, A.213, A.214, A.401a, A.401b, A.401c, A.402a, A.402b,
A.402c, A.403a, A.403b, A.403c, A.403d, A.404a, A.405, A.406, D.110, D.111, D.114,
D.201, D.202, D.301, E.001, E.101, E.102, E.103, E.104, E.201, E.202, G.001, G.002,
L.001, L.002, L.003, L.004, P.114, and PD.114, except as may be amended by
conditions in this resolution. Sheets S0.0, S1.0, S2.0, S2.1, S3.0, S4.0, S5.0, S5.1, and
S6.0 were neither reviewed nor approved as part of this project.
2. ACCURACY OF PROJECT PLANS
The applicant/property owner is responsible to verify all pertinent property data
including but not limited to property boundary locations, building setbacks,
property size, building square footage, any relevant easements and/or
construction records. Any misrepresentation of any property data may invalidate
this approval and may require additional review.
3. CONCURRENT APPROVAL CONDITIONS
The conditions of approval contained in file no. TR-2019-034 shall be applicable to
this approval.
4. ANNOTATION OF THE CONDITIONS OF APPROVAL
The conditions of approval set forth shall be incorporated into and annotated on
the first page of the building plans.
5. EXTERIOR BUILDING MATERIALS/TREATMENTS
a. The final building exterior plan shall closely resemble the details shown on the
original approved plans.
b. All final building exterior treatment plan (including but not limited to details
on exterior color, materials, architectural treatments, doors, windows, lighting
fixtures, and/or embellishments) shall be reviewed and approved by the
Resolution No. 115 ASA-2019-007 May 14, 2020
Page 5
Director of Community Development prior to issuance of building permits to
ensure quality and consistency.
c. Any exterior changes determined to be substantial by the Director of
Community Development shall either require a modification to this permit or
a new permit based on the extent of the change.
6. LANDSCAPE PROJECT SUBMITTAL
Prior to issuance of building permits, the applicant shall submit a full Landscape
Documentation Package, per sections 14.15.050 A, B, C, and D of the Landscape
Ordinance, for projects with landscape area 500 square feet or more The Landscape
Documentation Package shall be reviewed and approved to the satisfaction of the
Director of Community Development prior to issuance of building permits, and
additional requirements per sections 14.15.050 E, F, G, H, and I will be required to be
reviewed and approved prior to final inspections.
7. LANDSCAPE INSTALLATION REPORT
The project is subject to all provisions delineated in the Landscape Ordinance (CMC,
Chapter 14.15). A landscape installation audit shall be conducted by a certified
landscape professional after the landscaping and irrigation system have been
installed. The findings of the assessment shall be consolidated into a landscape
installation report.
The landscape installation report shall include but is not limited to: inspection to
confirm that the landscaping and irrigation system are installed as specified in the
landscape and irrigation design plan, system tune-up, system test with distribution
uniformity, reporting overspray or run-off that causes overland flow, and preparation
of an irrigation schedule.
The landscape installation report shall include the following statement: “The
landscape and irrigation system have been installed as specified in the landscape and
irrigation design plan and complies with the criteria of the ordinance and the permit.”
8. LANDSCAPE AND IRRIGATION MAINTENANCE
Per the Landscape Ordinance (CMC, Chapter 14.15), a maintenance schedule shall be
established and submitted to the Director of Community Development or his/her
designee, either with the landscape application package, with the landscape
installation report, or any time before the landscape installation report is submitted.
a. Schedules should take into account water requirements for the plant
establishment period and water requirements for established landscapes.
b. Maintenance shall include, but not be limited to the following: routine
inspection; pressure testing, adjustment and repair of the irrigation system;
Resolution No. 115 ASA-2019-007 May 14, 2020
Page 6
aerating and de-thatching turf areas; replenishing mulch; fertilizing; pruning;
replanting of failed plants; weeding; pest control; and removing obstructions
to emission devices.
c. Failed plants shall be replaced with the same or functionally equivalent plants
that may be size-adjusted as appropriate for the stage of growth of the overall
installation. Failing plants shall either be replaced or be revived through
appropriate adjustments in water, nutrients, pest control or other factors as
recommended by a landscaping professional.
9. SIGNAGE
Signage is not approved with this application. Signage shall conform to the City
Sign Code.
10. LIGHTING
On-site lighting must be in conformance with Cupertino Municipal Code Chapters
19.60 and 19.124.
11. DEMOLITION REQUIREMENTS
All demolished building and site materials shall be recycled to the maximum
extent feasible subject to the Building Official. The applicant shall provide
evidence that materials were recycled prior to occupancy.
12. GRADING AND CONSTRUCTION HOURS AND NOISE LIMITS
The applicant shall indicate compliance with the following grading and
construction hours and noise limit requirements on all demolition, construction
and grading permits, and in the construction management plan(s), unless
otherwise indicated.
a. All grading activities shall be limited to the dry season (April 15 to October 1),
unless permitted otherwise by the Director of Public works.
b. Construction hours and noise limits shall be compliant with all requirements
of Chapter 10.48 of the Cupertino Municipal Code.
c. Grading, street construction, underground utility and demolition hours for
work done more than 750 feet away from residential areas shall be limited to
Monday through Friday, 7 a.m. to 8 p.m. and Saturday and Sunday, 9 a.m. to
6 p.m. Grading, street construction, demolition or underground utility work
within 750 feet of residential areas shall not occur on Saturdays, Sundays,
holidays, and during nighttime period as defined in Section 10.48.053(b) of the
Municipal Code.
d. Construction activities shall be limited to Monday through Friday, 7 a.m. to 8
p.m. and Saturday and Sunday, 9 a.m. to 6 p.m. Construction activities are not
Resolution No. 115 ASA-2019-007 May 14, 2020
Page 7
allowed on holidays as defined in Chapter 10.48 of the Municipal Code. Night
time construction is allowed if compliant with nighttime standards of Section
10.48 of the Cupertino Municipal Code.
e. Rules and regulations pertaining to all construction activities and limitations
identified in this permit, along with the name and telephone number of an
applicant appointed disturbance coordinator, shall be posted in a prominent
location at the entrance to the job site.
f. The applicant shall be responsible for educating all contractors and
subcontractors of said construction restrictions.
13. BAAQMD BASIC CONTROL MEASURES (DUST CONTROL)
Project shall comply with the Bay Area Quality Management District’s Basic
Construction Mitigation Measures as follows:
a. All exposed surfaces (e.g., parking areas, staging areas, soil piles, graded areas,
and unpaved access roads) shall be watered two times per day.
b. All haul trucks transporting soil, sand, or other loose material off-site shall be
covered.
c. All visible mud or dirt tracked-out onto adjacent public roads shall be removed
using wet power vacuum street sweepers at least once per day. The use of dry
power sweeping is prohibited.
d. All vehicle speeds on unpaved roads shall be limited to 15 mph.
e. All roadways, driveways, and sidewalks to be paved shall be completed as
soon as possible. Building pads shall be laid as soon as possible after grading
unless seeding or soil binders are used.
f. Idling times shall be minimized either by shutting equipment off when not in
use or reducing the maximum idling time to 5 minutes (as required by the
California airborne toxics control measure Title 13, Section 2485 of California
Code of Regulations [CCR]). Clear signage shall be provided for construction
workers at all access points.
g. All construction equipment shall be maintained and properly tuned in
accordance with manufacturer’s specifications. All equipment shall be checked
by a certified mechanic and determined to be running in proper condition prior
to operation.
h. A publicly visible sign shall be posted with the telephone number and person
to contact at the City of Cupertino regarding dust complaints. This person shall
respond and take corrective action within 48 hours. The BAAQMD phone
number shall also be visible to ensure compliance with applicable regulations.
Resolution No. 115 ASA-2019-007 May 14, 2020
Page 8
Applicant shall indicate compliance with BAAQMD’s basic control measures on
all demolition, construction and grading permits and construction management
plan(s).
14. CONSULTATION WITH OTHER DEPARTMENTS
The applicant is responsible to consult with other departments and/or agencies
with regard to the proposed project for additional conditions and requirements.
Any misrepresentation of any submitted data may invalidate an approval by the
Community Development Department.
15. INDEMNIFICATION
The applicant agrees that, to the fullest extent permitted by law, the applicant shall
indemnify, defend with the attorneys of the City’s choice, and hold harmless the
City, its City Council, and its officers, employees, and agents (collectively, the
“indemnified parties”) from and against any liability, claim, action, cause of
action, suit, damages, judgment, lien, levy, or proceeding brought by a third party
against one or more of the indemnified parties or one or more of the indemnified
parties and the applicant related to any Ordinance, Resolution, or action
approving the project, the related entitlements, environmental review documents,
finding or determinations, or any other permit or approval authorized for the
project, including (without limitation) reimbursing the City its actual attorneys’
fees and costs incurred in defense of the litigation. The applicant shall pay such
attorneys’ fees and costs within 30 (thirty) days following receipt of invoices from
City. Such attorneys’ fees and costs shall include amounts paid to the City’s
outside counsel and shall include City Attorney time and overhead costs and other
City staff overhead costs and any costs directly related to the litigation reasonably
incurred by City. The applicant shall likewise indemnify, defend, and hold
harmless the indemnified parties from and against any damages, attorneys’ fees,
or costs awards, including attorneys’ fees awarded under Code of Civil Procedure
section 1021.5, assessed or awarded against the indemnified parties.
The Applicant further agrees to defend, indemnify and hold harmless the
indemnified parties for all cost incurred in additional investigation or study of, or
for supplementing, redrafting, revising, or amending any document (such as an
Environmental Impact Report, negative declaration, specific plan, or general plan
amendment) if made necessary by proceedings challenging the project approvals
and related environmental review if the applicant desires to continue to pursue
the project.
16. NOTICE OF FEES, DEDICATIONS, RESERVATIONS, OR OTHER EXACTIONS
The Conditions of Project Approval set forth herein may include certain fees,
dedication requirements, reservation requirements, and other exactions. Pursuant
to Government Code Section 66020(d) (1), these Conditions constitute written
Resolution No. 115 ASA-2019-007 May 14, 2020
Page 9
notice of a statement of the amount of such fees, and a description of the
dedications, reservations, and other exactions. You are hereby further notified that
the 90-day approval period in which you may protest these fees, dedications,
reservations, and other exactions, pursuant to Government Code Section 66020(a),
has begun. If you fail to file a protest within this 90-day period complying with all
of the requirements of Section 66020, you will be legally barred from later
challenging such exactions.
SECTION IV: CONDITIONS ADMINISTERED BY THE ENVIRONMENTAL SERVICES
DEPARTMENT
17. TRASH ENCLOSURE MODIFICATION
SHEET A.406: Please reconfigure the storm drain within the trash enclosure to an
area outside of the structure. The full trash capture device identified should remain
on the relocated storm drain inlet. Please note that the Sanitary District may require
a sanitary drain within the enclosure with a filter system. Please inquire directly with
them for their requirements.
SHEETS A.110, A.406, and Page 12 of Exhibit A (1987 topographic site survey): Please
identify the location of the relocated storm drain inlet from the trash enclosure.
Include the specific model of full trash capture device to be installed to the inlet.
SECTION V: CONDITIONS ADMINISTERED BY THE FIRE DEPARTMENT
18. FIRE SPRINKLER MODIFICATIONS
This building is equipped with a fire sprinkler system. Any modifications to the
structure may require modification of the fire sprinkler system and will be
determined during architectural review. A State of California licenses (C-16) Fire
Protection Contractor shall submit plans, calculations, a completed permit
application and appropriate fees to this department for review and approval prior
to beginning their work. Call (408) 378-4010 for more information.
19. FIRE ALARM SYSTEM
This building is equipped with a fire alarm system. Any modifications to the
structure may require modification of the fire alarm system and will be determined
during architectural review. Any modifications to the current system will require
submittal of shop drawings (3 sets) and a permit application to the Fire Prevention
Division for review and approval before installing the system. Call (408) 378-4010
for more information.
Resolution No. 115 ASA-2019-007 May 14, 2020
Page 10
20. EXITING
All required exits and paths of egress shall be kept unobstructed and maintained
at all times.
21. FIRE LANE & HYDRANTS
All fire lanes shall be maintained and unobstructed access provided to fire
hydrants at all times.
22. CONSTRUCTION SITE FIRE SAFETY
All construction sites must comply with applicable provisions of the CFC Chapter
33 and our Standard Detail and Specification SI-7. Provide appropriate notations
on subsequent plan submittals, as appropriate to the project. CFC Chp. 33.
PASSED AND ADOPTED this 14th day of May 2020 at a noticed Public Meeting of the
Administrative Hearing Officer of the City of Cupertino, State of California, held by the
Director of Community Development, or his or her designee, pursuant to Cupertino
Municipal Code Section 19.12.120.
ATTEST: APPROVED:
/s/Erika Poveda /s/Albert Salvador
Erika Poveda Albert Salvador
Associate Planner Assistant Director of Community Development
TR-2019-034
CITY OF CUPERTINO
10300 Torre Avenue
Cupertino, California 95014
RESOLUTION NO. 116
OF THE ADMINISTRATIVE HEARING OFFICER OF THE CITY OF
CUPERTINO APPROVING A TREE REMOVAL PERMIT TO ALLOW
THE REMOVAL AND REPLACEMENT OF FIFTEEN
PROTECTED TREES LOCATEDAT 10605 N. WOLFE ROAD
SECTION I: PROJECT DESCRIPTION
Application No.: TR-2019-034
Applicant: Tom Young (Spectrum Development/Courtyard by Marriott)
Location: 10605 N. Wolfe Road (APN 316-47-049)
SECTION II: FINDINGS TREE REMOVAL PERMIT:
WHEREAS, the City of Cupertino received an application for a Tree Removal permit as
described in Section I of this Resolution; and
WHEREAS, the necessary public notices have been given as required by the Procedural
Ordinance of the City of Cupertino, and the Administrative Hearing Officer has held at
least one public meeting in regard to the application; and
WHEREAS, pursuant to the provisions of the California Environmental Quality Act of
1970 (Public Resources Code section 21000 et seq.) (“CEQA”), together with the State
CEQA Guidelines (California Code of Regulations, Title 14, Section 15000 et seq.)
(hereinafter, "CEQA Guidelines"), the City staff has independently studied the proposed
Project and has determined that the Project is exempt from environmental review
pursuant to the categorical exemption in CEQA Guidelines section 15304 for the reasons
set forth in the staff report dated May 14, 2020 and incorporated herein; and
WHEREAS, the applicant has met the burden of proof required to support said
application; and
WHEREAS, the Administrative Hearing Officer finds as follows with regard to this
application:
Resolution No. 116 TR-2019-034 May 14, 2020
Page 2
1. That the protected trees are a detriment to the subject property and cannot be
adequately supported according to good urban forestry practices due to the
overplanting or overcrowding of trees on the subject property.
The proposed tree removals are supported due to poor initial planting locations not suitable for
the continued growth and maintenance of the trees. The proposed tree replacements will
improve the aesthetics of the site for its users. The City’s consulting arborist has reviewed the
arborist report and takes no exception to the proposal for removal.
NOW, THEREFORE, BE IT RESOLVED:
That after careful consideration of the maps, facts, exhibits, testimony, staff’s report and
presentation, and other evidence submitted in this matter, subject to the conditions which
are enumerated in this Resolution beginning on PAGE 2 thereof:
The application for a Tree Removal permit, Application no. TR-2019-034 is hereby
approved and that the subconclusions upon which the findings and conditions specified
in this resolution are based and contained in the Public Meeting record concerning
Application no. TR-2019-034 as set forth in the Minutes of the Administrative Hearing
Meeting of May 14, 2020 and are incorporated by reference as though fully set forth herein.
SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY
DEVELOPMENT DEPT.
1. APPROVED EXHIBITS
This approval for tree removal is based on the certified arborist report prepared by
Lori Murphy (ISA Certified Arborist, WE-7844AM) with Davey Resource Group,
dated September 4, 2019 and consisting of 24 pages; and the tree replacement plan
drawn by licensed landscape architect, Melvin R. Easter (LA # 4128), consisting of one
(1) page labeled L.002, except as may be amended by conditions in this resolution.
2. TREE #3 TO BE RETAINED
This approval is for the removal of the fifteen (15) protected trees outlined in the
certified arborist report with the exception of Tree #3, 6” DBH Cherry Plum (Prunus
cerasifera), as indicated in the arborist’s Tree Inventory. Tree #3 shall be retained on
site and protected.
3. ACCURACY OF PROJECT PLANS
The applicant/property owner is responsible to verify all pertinent property data
including but not limited to property boundary locations, building setbacks, property
size, building square footage, any relevant easements and/or construction records.
Resolution No. 116 TR-2019-034 May 14, 2020
Page 3
Any misrepresentation of any property data may invalidate this approval and may
require additional review.
4. CONCURRENT APPROVAL CONDITIONS
The conditions of approval contained in file no. ASA-2019-007 shall be applicable to
this approval.
5. PREVIOUS CONDITIONS OF APPROVAL
All previous conditions of approval, in accordance with TR-2010-12 shall remain
in effect except as may be amended by conditions contained in this resolution.
6. FINAL PLANTING PLAN
The applicant shall plant replacement trees in accordance with the replacement
requirements of the Protected Tree Ordinance. The trees shall be planted prior to final
occupancy of site permits.
The final planting plan shall be reviewed and approved by the Director of Community
Development prior to issuance of building permits. The Director of Community
Development shall have the discretion to require additional tree replacements as
deemed necessary. An ISA Certified Arborist shall confirm that the replacement trees
were planted properly and according to plan prior to final occupancy.
7. TREE REPLACEMENTS
The applicant is required to plant replacement trees in accordance with the Protected
Tree Ordinance and per the approved replacement plan.
8. TREE PROTECTION
As part of the demolition or building permit drawings, a tree protection plan shall be
prepared by a certified arborist for the trees to be retained. In addition, the following
measures shall be added to the protection plan:
a. For trees to be retained, chain link fencing and other root protection shall be
installed around the dripline of the tree prior to any project site work.
b. Signs indicating the protected status of the tree shall be installed on the protective
fencing.
c. Tree protection conditions shall be posted on the tree protection fencing.
d. No parking or vehicle traffic shall be allowed under root zones, unless using
buffers approved by the Project Arborist.
e. No trenching within the critical root zone area is allowed. If trenching is needed
in the vicinity of trees to be retained, the City’s consulting arborist shall be
consulted before any trenching or root cutting beneath the dripline of the tree.
Resolution No. 116 TR-2019-034 May 14, 2020
Page 4
f. Wood chip mulch shall be evenly spread inside the tree projection fence to a four-
inch depth.
g. Retained trees shall continue to be irrigated or hand-watered to maintain them in
good health.
The tree protection measures shall be inspected and approved by the certified arborist
prior to issuance of building permits.
The City’s consulting arborist shall inspect the trees to be retained and shall provide
reviews prior to issuance of demolition, grading or building permits. Additionally, a
report ascertaining the good health of the trees mentioned above shall be provided
prior to issuance of final occupancy. Any trees identified to be in poor health or
incongruent with the site-wide tree replacement plan in the report shall be required
to be removed and replaced.
9. TREE AND LANDSCAPE MAINTENANCE
The property owner shall be responsible for ensuring that the existing trees and newly
planted trees are properly maintained including but not limited to ensuring that there
is adequate soil drainage, that the soil is well-aerated, and irrigation systems are
thoroughly tested to provide sufficient water to landscaped areas while reducing
water waste.
10. DISCLOSURE OF PROTECTED TREES AND COVENANT
The property owner/applicant understands that the replacement trees may not be
removed without a Tree Removal Permit and that they shall be responsible for
ensuring the ongoing proper maintenance and care of the trees. The location and
species of all replacements trees on site shall be disclosed upon sale of the property.
In addition, a covenant shall be recorded on the property that identifies all the
protected trees, prior to final occupancy.
11. CONSULTATION WITH OTHER DEPARTMENTS
The applicant is responsible for consulting with other departments and/or agencies
with regard to the proposed project for additional conditions and requirements. Any
misrepresentation of any submitted data may invalidate an approval by the
Community Development Department.
12. INDEMNIFICATION
The applicant agrees that, to the fullest extent permitted by law, the applicant shall
indemnify, defend with the attorneys of the City’s choice, and hold harmless the City,
its City Council, and its officers, employees, and agents (collectively, the “indemnified
parties”) from and against any liability, claim, action, cause of action, suit, damages,
judgment, lien, levy, or proceeding brought by a third party against one or more of
Resolution No. 116 TR-2019-034 May 14, 2020
Page 5
the indemnified parties or one or more of the indemnified parties and the applicant
related to any Ordinance, Resolution, or action approving the project, the related
entitlements, environmental review documents, finding or determinations, or any
other permit or approval authorized for the project, including (without limitation)
reimbursing the City its actual attorneys’ fees and costs incurred in defense of the
litigation. The applicant shall pay such attorneys’ fees and costs within 30 (thirty) days
following receipt of invoices from City. Such attorneys’ fees and costs shall include
amounts paid to the City’s outside counsel and shall include City Attorney time and
overhead costs and other City staff overhead costs and any costs directly related to
the litigation reasonably incurred by City. The applicant shall likewise indemnify,
defend, and hold harmless the indemnified parties from and against any damages,
attorneys’ fees, or costs awards, including attorneys’ fees awarded under Code of
Civil Procedure section 1021.5, assessed or awarded against the indemnified parties.
The Applicant further agrees to defend, indemnify and hold harmless the indemnified
parties for all cost incurred in additional investigation or study of, or for
supplementing, redrafting, revising, or amending any document (such as an
Environmental Impact Report, negative declaration, specific plan, or general plan
amendment) if made necessary by proceedings challenging the project approvals and
related environmental review if the applicant desires to continue to pursue the project.
13. NOTICE OF FEES, DEDICATIONS, RESERVATIONS, OR OTHER EXACTIONS
The Conditions of Project Approval set forth herein may include certain fees,
dedication requirements, reservation requirements, and other exactions. Pursuant to
Government Code Section 66020(d) (1), these Conditions constitute written notice of
a statement of the amount of such fees, and a description of the dedications,
reservations, and other exactions. You are hereby further notified that the 90-day
approval period in which you may protest these fees, dedications, reservations, and
other exactions, pursuant to Government Code Section 66020(a), has begun. If you
fail to file a protest within this 90-day period complying with all of the requirements
of Section 66020, you will be legally barred from later challenging such exactions.
Resolution No. 116 TR-2019-034 May 14, 2020
Page 6
PASSED AND ADOPTED this 14th day of May 2020 at a noticed Public Meeting of the
Administrative Hearing Officer of the City of Cupertino, State of California, held by the
Director of Community Development, or his or her designee, pursuant to Cupertino
Municipal Code Section 19.12.120.
ATTEST: APPROVED:
/s/Erika Poveda /s/Albert Salvador
Erika Poveda Albert Salvador
Associate Planner Assistant Director of Community Development
Corporate Headquarters
1500 North Mantua Street
P.O. Box 5193
Kent, OH 4240-5193
330-673-5685
Toll Free 1-800-828-8312
Fax: 330-673-0860
Regional Office
6005 Capistrano Ave. Suite A
Atascadero, CA 93422
Direct: 503-880-3818
Lori.Murphy@Davey.com
September 4th, 2019
Ashley Seay
Baskervill
101 S. 15th St. Suite 200
Richmond, VA 23219
aseay@baskervill.com
804.728.3015
RE: Tree Inventory and Arborist Report for Courtyard Hotel in Cupertino, CA
Dear Ms. Seay,
Thank you for contracting with Davey Resource Group Inc.(DRG)regarding the above project.In support of your
objectives DRG is pleased to provide you with the attached report for the planned project.
A DRG International Society of Arboriculture (ISA)Certified Arborist (#PD-2444A)conducted the site assessment of
sixteen trees that are planned for removal prior to landscaping upgrades at the Courtyard Hotel in Cupertino,
California.The trees were assessed for location,size,current condition,and overall health to assist with design
considerations for landscape upgrades and tree removals.The attached report can be used to assist with tree removal
permitting.
The survey determined the following:
▪ Sixteen (16) trees were evaluated
▪ Seven (7)distinct species were identified.The most common species was southern live oak (Quercus
virginiana)
▪ Tree condition was rated from good to critical
▪ All trees fall under protected status as defined by the City of Cupertino, CA (Ch. 14.18.050,C)
▪ New landscape installation will require hand digging to reduce impacts to roots of retained trees
Please feel free to contact me if you would like more information or have any questions.
Sincerely,
Lori Murphy - Consulting Arborist
Davey Resource Group Inc.
Certified Arborist #WE-7844-AM
916-899-7917
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
TREE INVENTORY
AND ARBORIST REPORT
Courtyard Hotel
10605 N. Wolfe Rd.
Cupertino, CA
September 2019
Courtyard Hotel
Cupertino, CA 2 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Tree Inventory and Arborist Report
Courtyard Hotel, 10605 N. Wolfe Rd.,
Cupertino, California
Prepared for
Ashley Seay
Baskervill
1 01 S. 15th St., Suite 200
Richmond, VA 23219
September 2019
Prepared by:
Davey Resource Group
A Division of The Davey Tree Expert Company
1500 North Mantua Street
Kent, OH 44240
Contact:
Lori Murphy
Certified Arborist #WE-7844AM
ISA Tree Risk Assessment Qualified
www.d aveyresourcegroup.com
Lori Murphy
ISA Arborist #WE 7844 AM
ISA Tree Risk Assessment Qualified
www.d aveyresourcegroup.com
Notice of Disclaimer
Inventory data provided by Davey Resource Group is based on visual recording at the time of inspection. Visual records do
not include testing or analysis and do not include aerial or subterranean inspection. Davey Resource group is not
responsible for discovery or identification of hidden or otherwise non-observable risks. Records may not remain
accurate after inspection due to variable deterioration of inventoried material and site disturbance. Davey
Resource Group provides no warran ty with respect to the fitn ess of the urban forest for any use or purpose
whatsoever or for future outcomes of the in ven toried trees.
Courtyard Hotel
Cupertino, CA 3 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Contents
Summary 5
Introduction 5
Assignment 5
Limits of Assignment 5
Purpose and Use of Report 5
Observations 6
Methods 6
Site Observations 6
Analysis and Discussion 6
Conclusion and Recommendations 7
Landscape Comments 7
Appendix A – Tree Inventory and Condition Assessment 8
Table 1. Tree Inventory July 2019 8
Table 2. Condition Assessment August 2019 9
Appendix B – Photos 10
Appendix C - Area Map 24
Courtyard Hotel
Cupertino, CA 4 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Summary
In August 2019,Davey Resource Group,Inc.(DRG)was contracted by Ms.Ashley Seay of Baskervill to conduct a tree
inventory and develop an arborist report for sixteen (16)client-identified trees slated for removal to facilitate site and
landscape upgrades at the Courtyard by Marriott Hotel in Cupertino, CA.
An International Society of Arboriculture (ISA)Certified Arborist from DRG (PD-2444A)conducted an evaluation of
the trees on August 22nd and 28th,2019.The data set was collected as GIS-based tree inventory and trees were
assessed by their location,size,current condition,and overall health.The evaluations determined,based on visual
inspection,tree condition ratings ranged from good (11 trees)to fair (3 trees).Two redwood trees were in critical
condition. Only trees identified by the project contact were assessed.
Introduction
Assignment
Baskervill architects are coordinating with Courtyard Hotel to implement landscape and site upgrades around the
hotel.DRG received a landscape plan of the site that detailed those trees slated for removal.The trees are protected
under Cupertino Municipal Code Chapter 14.18.050-C as part of an approved development and require a permit for
removal.
This inventory establishes the quantity and condition of trees slated for removal.The condition of each tree was
visually assessed and photographed.The property managers are planning landscape upgrades and proactive removals
on the site and replacing these with more appropriate species.This tree inventory is intended to help apply for
necessary tree removal permits.By proactively managing trees adjacent to buildings and other assets,managers are
planning for the necessary steps to create a plan for a sustainable low-maintenance landscape.
Limits of Assignment
Many factors can limit specific and accurate data when performing evaluations of trees,their conditions,and potential
for failure or response to site disturbances.No soil or tissue testing was performed.All observations were made from
the ground on August 22nd and 28th,2019,and no soil excavation to expose roots was performed.The
determinations and recommendations presented here are based on current data and conditions that existed at the
time of the evaluation and cannot be a predictor of the ultimate outcome for the evaluated trees in the future.
Purpose and Use of Report
The scope of work includes only inventoried trees as identified by the client.The purpose is to help create a
sustainable landscape through strategic removal and replacement with appropriate species.This report will be used to
facilitate tree removal permitting with the City of Cupertino.
This report outlines strategies to help property managers interpret tree data collected and provide long-term
management recommendations.Effective care of this tree population requires the management plan to address
potential impacts and to the building and hardscape.The planned upgrades provide long term strategies for ensuring
the safety and overall health of the trees on site.
Overall,trees are an important component of the urban ecosystem.Property managers have an opportunity to
steward this resource proactively in order to maintain safety and property values and guide maintenance planning
which will enhance and preserve the beauty and livability within the surrounding community.With appropriate
management the trees will be vital assets to the property for many years to come.
Courtyard Hotel
Cupertino, CA 5 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Observations
Methods
Only a visual inspection was used to develop the findings,conclusions,and recommendations found in this report.For
each tree,diameter at breast height (DBH)was collected using the following methods.All trees identified by the client
as planned for removal were collected. Shrubs were not required to be included in the inventory.
Data collection also included height estimation,canopy radius estimation,a visual assessment of tree condition,
structure,and health,and a photographic record of trees and site conditions.To assign condition,numerical values
were assigned to grade the attributes of the roots,trunk,branches,and foliage,including structure and health,and
averaged to obtain an overall condition rating.No physical inspection of the upper canopy,sounding,root crown
excavation, resistance drilling, or other technologies were used in the evaluation of the trees.
Site Observations
The inventory took place at the The Courtyard Hotel located at 10605 N.Wolfe Rd.north of Interstate 280 in
Cupertino,California.Many planting locations next to the building are narrow and limiting the growth of the trees.The
site is level and trees are irrigated.
Tree Observations
Sixteen (16)trees were assessed within the project area including seven distinct species.The most common species is
southern live oak (Quercus virginiana,7 trees),with camphor tree (Cinnamomum camphora,2 trees),coast redwood
(Sequoia sempervirens,2 trees),and Eastern redbud (Cercis canadensis,2 trees)were the next most prevalent species.
There is only one specimen each of Australian willow (Geijera parviflora
),Austrian black pine (Pinus thunbergiana),
and cherry plum (Prunus cerasifera
).Tree condition ratings for most trees was good (11 trees)and three (3)trees are
in fair condition.The two redwoods are in critical condition due to a serious decline in health.Tree diameters ranged
from 2”to 15”with an average of 11”and heights ranged from 10’to 35’with an average of 26’.The tree inventory is
a mixed age population from young to mature.
The completeTree Inventory and Condition Assessment can be found in Appendix A and tree photographs can be
found in Appendix B.
Analysis and Discussion
Preliminary designs were provided and reviewed for this Arborist Report.Renovation includes upgrades to the existing
landscape including removal of 16 trees.Two of the trees (#15 )are in critical condition,and two (#1 )will
have significant impacts from entryway construction.One tree (#3)will be impacted by a bike storage installation and
the remaining trees are outgrowing available planting space.The trees next to the building need room to expand
without need for excessive pruning to keep them from causing damage.Trees planted in inappropriate locations for
their species ultimately require significant maintenance as they continue to grow to their genetic potential and are
repeatedly pruned,sometimes multiple times per year.For example,southern live oak is an evergreen tree with a
growth rate of two to three feet per year.The mature stature is over fifty feet (50’)feet tall and sixty feet (60’)wide.
In order to be a sustainable landscape asset,this tree requires a minimum of 30’clearance in all directions from the
trunk.
Courtyard Hotel
Cupertino, CA 6 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Conclusion and Recommendations
Based on visual evaluations and review of site plans,it was determined that 16 trees are slated for removal.The
majority of assessed trees are in good to fair condition and two are in serious decline.Most trees are planted in
growth limiting spaces.While canopy loss is a concern,removing these trees and replacing them with species that are
more suitable to the available grow space will promote the health and vigor of the trees to be retained.DRG
recommends removal of all sixteen subject trees and re-planting with suitable species that will not overwhelm
buildings and crowd adjacent trees.Suitable species include fruitless olive (Olea europaea ‘Monher’),upright
Streetspire oak (Quercus robur x alba ‘JFS-KW1QX’),and crape myrtle (Lagerstroemia indica).With thoughtful
consideration to available space and species choices and planning for the mature height,spread,and root growth of
the trees will help to ensure that the tree population can sustainably reach maturity and provide the social and
environmental benefits intended.Conducting this tree inventory highlighted some opportunities to mitigate or relieve
negative impacts through the removal of certain trees.
Landscape Comments
Careful installation of new landscaping by hand digging will reduce impacts to trees that will be retained.Best
Management Practices (BMP)in tree preservation recommend impacting no more than twenty five percent of a tree’s
root system.A ten foot minimum excavation free zone around all existing trees should be observed to help ensure
maximum survivability of these trees.Also,a five foot clearance from the trunk of all newly installed trees is
recommended to reduce competition for rooting space.As is true of all landscape plans,proper hydrozoning is
necessary for sustainable landscapes.
Courtyard Hotel
Cupertino, CA 7 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Appendix A – Tree Inventory and Condition Assessment
Table 1. Tree Inventory August 2019
Tree
#DBH Common Name Botanical Name Condition
Rating Height Notes
1 15 Camphor tree Cinnamomum
camphora Good 35 Hardscape damage
2 14 Camphor tree Cinnamomum
camphora Fair 35 Stressed
3 6 Cherry plum Prunus cerasifera Fair 16 Poor structure, root damage
4 15 Southern live oak Quercus virginiana Good 35 One-sided
5 15 Southern live oak Quercus virginiana Good 35 One-sided
6 14 Southern live oak Quercus virginiana Good 35 One-sided
7 14 Southern live oak Quercus virginiana Fair 35 Basal decay
8 8 Japanese black pine Pinus thunbergiana Good 10
9 14 Australian willow Geijera parviflora Good 25 Crowded location
10 12 Southern live oak Quercus virginiana Good 25 Signs of stress
11 12 Southern live oak Quercus virginiana Good 25 One-sided
12 12 Southern live oak Quercus virginiana Good 25 Signs of stress
13 2 Eastern redbud Cercis canadensis Good 12
14 3 Eastern redbud Cercis canadensis Good 12
15 10 Coast redwood Sequoia sempervirens Critical 35 Serious decline
16 7 Coast redwood Sequoia sempervirens Critical 25 Serious decline
Courtyard Hotel
Cupertino, CA 8 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Table 2. Condition Assessment August 2019
Tree
Number
Root
Health
Root
Structure
Trunk
Health
Trunk
Structure
Scaffold
Health
Scaffold
Structure
Twigs
Condition
Foliage
Condition
Condition
rating
1 3 3 3 3 3 3 2.5 3 73
2 3 3 3 3 2 3 2 3 69
3 2.5 2.5 3 2 3 2 3 3 70
4 3 3 3 3 3 3 3 3 75
5 2.5 3 3 3 3 3 3 3 73
6 2.5 3 3 3 3 3 3 3 73
7 2 3 2 3 3 3 3 3 69
8 2 3 3 3 3 3 2.5 2.5 72
9 3 3 3 3 3 3 3 3 75
10 3 3 3 3 3 3 2.5 3 73
11 3 3 3 3 3 3 3 3 75
12 3 3 3 3 3 3 3 3 75
13 3 3 3 3 3 3 3 3 75
14 3 3 3 3 3 3 3 3 75
15 1 1 .5 2 .5 2 0 .5 9
16 .5 1 .5 2 .5 2 0 0 9
Courtyard Hotel
Cupertino, CA 9 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Appendix B – Photos
Photo 1. Camphor tree #1 is damaging curb
Courtyard Hotel
Cupertino, CA 10 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Photo 2. Camphor tree #2 is showing signs of stress
Courtyard Hotel
Cupertino, CA 11 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Photo 3. Tree #3 has poor branch structure
Photo 4. Tree #3 leans
Courtyard Hotel
Cupertino, CA 12 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Photo 5. Tree #4 is growing too close to building
Courtyard Hotel
Cupertino, CA 13 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Photo 6. Tree #5 is one sided
Courtyard Hotel
Cupertino, CA 14 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Photo 7. Tree #6 is one sided
Courtyard Hotel
Cupertino, CA 15 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Photo 8. Tree #7 has unbalanced and off-center canopy
Courtyard Hotel
Cupertino, CA 16 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Photo 9. Tree #8 has an excessive lean
Courtyard Hotel
Cupertino, CA 17 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Photo 10. Tree #9 is growing very close to building
Courtyard Hotel
Cupertino, CA 18 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Photo #11. Tree #10 has unbalanced and off-center canopy
Courtyard Hotel
Cupertino, CA 19 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Photo 12. Tree #11 is one-sided
Courtyard Hotel
Cupertino, CA 20 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Photo 13. Tree #12 is unbalanced and one-sided
Courtyard Hotel
Cupertino, CA 21 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Photo 14. Tree #14 is planned for removal and replacement.
Courtyard Hotel
Cupertino, CA 22 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Photo 15. Trees #15 and #16 are in serious decline.
Courtyard Hotel
Cupertino, CA 23 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
Appendix C - Area Map
Courtyard Hotel
Cupertino, CA 24 September 2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
USE GROUP: A-3 / B / R-1 (NO CHANGE)
CONSTRUCTION TYPE (602): TYPE VA (NO CHANGE)
FULLY SPRINKLERED: YES (NO CHANGE)
FIRE ALARM SYSTEM: YES (NO CHANGE)
HEIGHT OF BUILDING: 47'-6 1/2" (3 STORIES) (NO CHANGE)
HIGH RISE: NO (NO CHANGE)
BUILDING CODES: 2016 CALIFORNIA BUILDING CODE, VOLUME 1 & 2
2016 CALIFORNIA EXISTING BUILDING CODE
MECHANICAL CODE: 2016 CALIFORNIA MECHANICAL CODE
PLUMBING CODE: 2016 CALIFORNIA PLUMBING CODE
ELECTRICAL CODE: 2016 CALIFORNIA ELECTRICAL CODE
FIRE CODE: 2016 CALIFORNIA FIRE CODE
ACCESSIBILITY CODE: 2016 CALIFORNIA BUILDING CODE, VOLUME 1 & 2
ENERGY CODE: 2016 CALIFORNIA ENERGY CODE
2016 CALIFORNIA GREEN BUILDING STANDARD CODE
CUPERTINO MUNICIPAL CODE
ASSESSOR'S PARC EL NUMBER: 316-47-019
ZONING AND LAND USE: ZONING - P(HOTEL);
LAND USE - COMMERCIAL RESIDENTIAL
FLOOR AREA RATIO (FAR): BUILDING AREA: 79,406 SQ.FT
LOT AREA: 154,624 SQ. FT
EXISTING FAR = 0.51
PROPOSED FAR (NO CHANGE)
LOT COVERAGE: EXISTING = 35,223 SF
PROPOSED = 35,911 SF
THIS IS FOR RENOVATION OF AN EXISTING HOTEL. THE EXTERIOR SCOPE INCLUDES A
NEW ARRIVAL PORTE COCHERE, NEW FEATURE FRAMES/ BUILD OUTS AT THE MAIN
ENTRY AND SIDE ENTRIES, BICYCLE PARKING, LANDSCAPING ENHANCEMENT,
EXTERIOR MATERIAL UPGRADES, A NEW TRASH ENCLOSURE, REMOVAL OF EXISTING
TREES AND PLANTING OF NEW TREES. GUESTROOMS ARE NOT INCLUDED IN PROJECT
SCOPE.
NO CHANGES TO EXISTING MEANS OF EGRESS
D
PROJECT
SITE
AREA IN SCOPE AREA NOT IN SCOPE
- BICYCLE PARKING
COURTYARD BY MARRIOTT -
SAN JOSE CUPERTINO, CA
10605 N WOLFE RD, CUPERTINO, CA 95014
SPECTRUM DEVELOPMENT GROUP
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:54:40 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
TITLE SHEET
05/14/2019 -
PERMIT SET
T.001
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
C O U RTYARD BY
M ARRIOTT - SAN
JOSE CUPERTINO,
CA
CODE DATA SUMMARY.DESCRIPTION OF WORK.
VICINITY MAP.
DRAWING INDEX.
SHEET
NO SHEET TITLE
REV
NO REV DATE
T.001 TITLE SHEET D 02/07/2020
G.001 3D VIEWS A 07/03/2019
G.002 3D VIEWS A 07/03/2019
S0.0 GENERAL NOTES C 1 1 /20/201 9
S1.0 KEY PLAN
S2.0 FOUNDATION PLANS - ENTRANCE AND STAIRS
S2.1 ROOF FRAMING PLANS - ENTRANCE
S3.0 ROOF FRAMING PLANS - STAIRS AND AWNINGS
S4.0 FOUNDATION DETAILS
S5.0 ROOF FRAMING DETAILS
S5.1 ROOF FRAMING DETAILS
S6.0 TRASH ENCLOSURE C 1 1 /20/201 9
L.001 EXISTING CONDITIONS & DEMOLITION PLAN C 1 1 /20/201 9
L.002 PLANTING PLAN C 1 1 /20/201 9
L.003 LANDSCAPE DETAILS, NOTES, & SCHEDULE C 1 1 /20/201 9
L.004 PLANT IMAGE BOARD (EX. & PROPOSED) C 1 1 /20/201 9
A.001 GENERAL DRAWING STANDARDS & NOTES
A.002 WINDOW TYPES, FRAME TYPES & SCHEDULE
A.010 EXISTING CONDITIONS - PHOTOGRAPHIC
DOCUMENTATION
A.01 1 SITE PLAN - ACCESSIBILITY
A.012 CONSTRUCTON MANAGEMENT PRACTICES
A.013 CALGREEN
D.110 DEMOLITION - SITE PLAN D 02/07/2020
D.111 DEMOLITION - 1ST FLOOR PLAN A 07/03/2019
D.114 DEMOLITION PLAN - ROOF A 07/03/2019
D.201 DEMOLITION - EXTERIOR ELEVATIONS D 02/07/2020
D.202 DEMOLITION - EXTERIOR ELEVATIONS - COURTYARD D 02/07/2020
D.301 DEMOLITION WALL SECTIONS D 02/07/2020
A.110 OVERALL PLANS - SITE D 02/07/2020
A.111 OVERALL PLANS - 1ST FLOOR PLAN D 02/07/2020
A.114 ROOF PLAN D 02/07/2020
A.201 EXTERIOR ELEVATIONS D 02/07/2020
A.202 EXTERIOR ELEVATIONS - COURTYARD D 02/07/2020
A.203 EXTERIOR ELEVATIONS, COLOR D 02/07/2020
A.204 EXTERIOR ELEVATIONS - COURTYARD, COLOR D 02/07/2020
A.211 ELEVATIONS - EXISTING & PROPOSED D 02/07/2020
A.212 ELEVATIONS - EXISTING & PROPOSED D 02/07/2020
A.213 ELEVATIONS - EXISTING & PROPOSED D 02/07/2020
A.214 ELEVATIONS - EXISTING & PROPOSED D 02/07/2020
A.401a ENLARGED PORTE COCHERE PLANS, REFLECTED CEILING
PLANS & ROOF PLANS
A.401b ENLARGED PORTE COCHERE SECTIONS AND ELEVATIONS
A.401c DETAILS - PORTE COCHERE
A.402a ENLARGED PLANS - MAIN ENTRANCE
A.402b ENLARGED SECTIONS - MAIN ENTRANCE
A.402c DETAILS - MAIN ENTRANCE
A.403a ENLARGED PLANS, REFLECTED CEILING PLANS & DETAILS
- FRONT STAIRCASE #1 & #2
A.403b ENLARGED ELEVATIONS - FRONT STAIRCASE #1 & #2
A.403c ENLARGED SECTIONS & DETAILS - FRONT STARICASE #1 &
#2
A.403d DETAILS - FRONT STIARCASE
A.404a ENLARGED PLANS, REFLECTED CEILING PLANS & DETAILS
- SIDE ENTRANCE
C 1 1 /20/201 9
A.405 ENLARGED PLANS, REFLECTED CEILING PLANS & DETAILS
- REAR STAIRCASE
A 07/03/2019
A.406 TRASH ENCLOSURE DETAILS D 02/07/2020
P.114 NEW WORK ROOF PLAN
PD.114 DEMOLITION ROOF PLAN
E.001 LEGEND, SPECS
E.101 GROUND FLOOR - DEMOLITION
E.102 GROUND FLOOR - NEW WORK C 1 1 /20/201 9
E.103 GROUND FLOOR - SITE PHOTOMETRICS C 1 1 /20/201 9
E.1 04 GROUND FLOOR - SITE BOUNDARY PHOTOMETRICS D 02/1 4/201 9
E.201 ELEVATIONS
E.202 ELEVATIONS
BASKERVILL
101 S. 15TH ST., SUITE 200 (23219)
P.O. BOX 400
RICHMOND, VA 2 32 1 8 -040 0
PHONE: (804) 343-1 01 0
WWW.BASKERVILL.COM
CONTACT: TERRI CALLAW AY &
ARCHITECT / INTERIORS / ENGINEER:
DAVIDO CONSULTING GROUP, INC.
9706 4TH AVE NE, SUITE 300
SEATTLE, WA 98115
PHONE: (206) 523-0024
CONTACT: MATTHEW C. SCHMITTER
STRUCTURAL ENGINEER:
SPECTRUM DEVELOPMENT GROUP
3605 SANDY PLAINS ROAD
SUITE 240 #414
MARIETTA, GA 30066
PHONE: (404) 229-6078
CONTACT: TOM YOUNG
CLIENT :
CLARION PARTNERS
1717 McKINNEY AVENUE
SUITE 1900
DALLAS, TX 75202
OWNER:
KEY PLAN - EXTERIOR REIMAGE
EXTERIOR REIMAGE
MARRIOTT INTERNATIONAL
10400 FERNWOOD RD
BETHESDA, MD 20817
PHONE: (301) 380 6299
PURCHASING AGENT:
VALERIE WARSHAW
PROJECT ALTERNATIVES
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
B 09/05/2 01 9 PRELIMINARY REVIEW -
REVISION #2
C 1 1 /20/2 01 9 BUILDING PERMIT REVIEW -
REVISION #3
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
SURROUNDING USE MAP
D
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
A
B
C
1D2D3D4D 5D 6D D
E 1E2E3E4E 5E 6E
1C2C3C4C 5C 6C
1B2B3B4B 5B 6B
1A2A3A4A 5A 6A
6 5 4 3 2 1
WINDOW TYPE (ALPHABETIC)
COLUMN LINE
WORK OR DATUM POINT
CEILING TYPE / FINISH
CEILING HEIGHT
FINISH TAG (PLANS)
DOOR NUMBER
PARTITION TYPE
DRAWING WHERE SHOWN
SECTION CALL-OUT
ELEVATION CALL-OUT
DRAWING WHERE SHOWN
DETAIL CALL-OUT
DRAWING WHERE SHOWN
KEYNOTE
FURNITURE TYPE
EE
EXISTING NEW
A4a
C
1 REVISION (NUMERIC)
?
C TAG 01
9' - 0" A.F.F.
ROOMNAME
A123
123A
ROOM NUMBER
BUILDING PORTION (WHEN USED)
1A
A101
SIM
FURN
A101
6AREF
6A REF6AREF
6AREF
A101
1A SIM
N
SW
E
33.00°
PROJECT NORTH
DELTA BETWEEN TRUE
& PROJECT NORTH
TRUE NORTH
F TAG 01
SHEET SEQUENCE
VIEW TYPE MODIFIER
0 = DEMOLITION PLANS
(OPTIONAL)
1 = FLOOR PLANS
2 = REFELECTED CEILING
PLANS
3 = FINISH PLANS
4 = FF&E PLANS
VIEW TYPE
0 = GENERAL / SCHEDULES
1 = PLANS
2 = EXTERIOR ELEVATIONS
& DETAILS
3 = OVERALL BUILDING &
EXTERIOR WALL
SECTIONS
4 = ENLARGED PLANS
5 = INTERIOR ELEVATIONS
& CASEWORK
6 = DETAILS
DISCIPLINE
T = TITLE SHEET & INDEX
G = GENERAL
B = GEOTECHNICAL /
ENVIRONMENTAL
D = DEMOLITION SERIES
C = CIVIL
L = LANDSCAPE
A = ARCHITECTURAL /
INTERIORS
I = INTERIORS
S = STRUCTURAL
F = FIRE PROTECTION
P = PLUMBING
M = MECHANICAL / HVAC
E = ELECTRICAL
X = OTHER
CONCRETE
MASONRY (CMU)
CONCRETE
PRECAST
CONCRETE
BRICK
STONE
STEEL
ALUMINUM
POROUS FILL
SOIL
RIGID INSULATION
BATT INSULATION
GYPSUM DRYWALL
PLASTER OR SAND
PLYWOOD
FRAMING LUMBER
FINISH WOOD
CERAMIC TILE
ACOUSTICAL PANELS
LIGHTWEIGHT
CONC. TOPPING
BLOCKING
USE OF TOBACCO PRODUCTS IS NOT PERMITTED ANYWHERE ON OWNER'S
PROPERTY. PROHIBIT USE OF ALL TOBACCO PRODUCTS, INCLUDING BUT NOT LIMITED
TO CIGARETTES, CIGARS, PIPES, CHEWING TOBACCO, SNUFF, DIP, SNUS AND
ELECTRONIC CIGARETTES BY ALL PERSONNEL COVERED BY THIS CONTRACT WHILE
ON OWNER'S PROPERTY. THIS PROHIBITION APPLIES TO OCCUPANTS OF JOBSITE
OFFICES, STORAGE OR WORK SHEDS, WORK AREAS ASSIGNED EXCLUSIVELY TO THE
CONTRACTOR, AND VEHICLES WHILE THE VEHICLE IS ON OWNER'S PROPERTY.
ENFORCE REQUIREMENTS STRICTLY.
DEFINITION: THE TERM "DESIGN PROFESSIONAL" MEANS "ARCHITECT", "PROFESSIONAL
ENGINEER", "INTERIOR DESIGNER" OR OTHER PARTY RESPONSIBLE FOR PROVIDING
DESIGN SERVICES AS APPROPRIATE.
1. VERIFY ALL EXISTING CONDITIONS.
2. CONTRACTOR TO MAINTAIN EGRESS ROUTES FROM EXISTING BUILDING
THROUGHOUT THE COURSE OF CONSTRUCTION.
3. VERTICAL DIMENSIONS ARE FROM "FLOOR LINE" UNLESS OTHERWISE NOTED.
REFER TO ELEVATIONS FOR "FLOOR LINE" DATUMS.
4. HORIZONTAL DIMENSIONS FOR NEW CONSTRUCTION ARE FROM FACE OF FINISH
UNLESS OTHERWISE NOTED. HORIZONTAL DIMENSIONS FOR EXISTING
CONSTRUCTION ARE FROM FACE OF EXISTING FINISHED SURFACE.
5. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF
CONFLICT, CONSULT WITH THE DESIGN PROFESSIONAL TO OBTAIN CLARIFICATION
BEFORE CONTINUING WITH CONSTRUCTION.
6. HOLES CUT THROUGH EXISTING OR NEW FIRE RATED CONSTRUCTION FOR
INSTALLATION OF PIPING, DUCTWORK, OR OTHER PENETRATIONS SHALL BE KEPT
TO A MINIMUM NUMBER AND HELD TO A MINIMUM SIZE. FILL VOIDS BETWEEN
PIPES, DUCTS, OTHER PENETRATING ITEMS AND RATED CONSTRUCTION WITH FIRE
RETARDANT SEALANT SYSTEM LISTED IN THE UL FIRE RESISTANCE DIRECTORY
WITH FIRE (F) AND TEMPERATURE (T) RATINGS EQUAL TO OR GREATER THAN THE
FIRE RESISTANCE RATING OF THE ASSEMBLY BEING SEALED.
7. ALIGN NEW FLOOR FINISHES WITH EXISTING ADJACENT FLOOR FINISHES UNLESS
OTHERWISE INDICATED WHERE NEW AND EXISTING FINISHED SURFACES ARE
INDICATED TO BE ALIGNED, INSTALL SO FINISHED SURFACES ARE FLUSH (FEATHER
MAXIMUM 1/8” PER FOUR FEET).
8. IT IS UNDERSTOOD AND AGREED THAT DRAWING REFINEMENTS, ADDITIONAL
DETAILING AND CLARIFICATIONS WILL BE ISSUED DURING THE CONSTRUCTION
SCHEDULE AND NO ADJUSTMENT WILL BE MADE IN THE CONTRACTORS’ OR SUB-
CONTRACTORS’ PRICE UNLESS SUCH REFINEMENT, DETAILING OR
CLARIFICATIONS RESULT IN CHANGES TO THE SCOPE, QUALITY, FUNCTION AND OR
INTENT OF THE DRAWINGS AND THE PROJECT MANUAL NOT REASONABLY
INFERABLE BY A CONTRACTOR OR SUB-CONTRACTOR EXPERIENCED IN THIS TYPE
OF WORK.
9. ALL CONTRACTORS AND SUB-CONTRACTORS MUST QUOTE ON COMPLETED, FULLY
OPERABLE SYSTEMS BASED ON THE DESIGN INTENT OF THE CONTRACT
DOCUMENTS, AND ALL MATERIAL AND LABOR IMPLIED THEREFROM.
10. UNLESS OTHERWISE REQUIRED BY THE OWNER, CONSTRUCTION ADMINISTRATION
SERVICES WILL BE COMPLETED USING NEWFORMA PROJECT CENTER.
REFERENCE DIVISION 1 OF THE SPECIFICATION FOR THE PROCEDURES FOR
REQUESTS FOR INFORMATION AND SUBMITTALS.
1. ALL FIREPROOFIN G DESIGNS SHOULD BE CONSIDERED THERMALLY
UNRESTRAINED.
2. SPRAYED FIREPROOFING FOR STRUCTURAL MEMBERS WITH W/D OR A/P RATIOS
OTHER THAN THE SPECIFIED UL DESIGN, WILL BE ADJUSTED IN ACCORDANCE
WITH THE ADJUSTMENT OF SPRAYED PROTECTION MATERIAL THICKNESS FOR
UNRESTRAINED RATINGS FOR VARIOUS BEAM AND COLUMN SIZES AS FOUND IN
THE MOST CURRENT EDITION OF THE UL FIRE RESISTANCE DIRECTORY.
3. ALL BEAMS AND COLUMNS SHALL BE ADJUSTED USING W/D OR A/P RATIOS TO
DETERMINE THE CORRECT FIREPROOFING THICKNESS.
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 12:14:04 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
GENERAL DRAWING
STANDARDS & NOTES
05/14/2019 -
PERMIT SET
A.001
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
CO U RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
ABBREVIATIONS
ABBRV FULL WORD
LIN LINEAR
LLV LONG LEG VERTICAL
LVR LOUVER
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MLD MOLDING
mm MILLIMETER
MO MASONRY OPENING
MT METAL THRESHOLD
MTL METAL
MULL MULLION
MWK MILLWORK
N NORTH
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFF OFFICE
OFOI OWNER FURNISHED OWNER INSTALLED
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPP H OPPOSITE HAND
OVFL OVERFLOW
#LBS POUNDS
PAR PARALLEL
PART PARTIAL
PARTN PARTITION
PERIM PERIMETER
PERP PERPENDICULAR
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER, PLASTIC
PLBG PLUMBING
PLWD PLYWOOD
PNL PANEL
PNT PAINT
PP PITCH POCKET
PR PAIR
PRV POWERED ROOF VENTILATOR
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED, PORCELAIN TILE
PWC PLASTIC WALL COVERING
QT QUARRY TILE
QTY QUANTITY
QUAL QUALITY
R RISER
RA RETURN AIR
RAD RADIUS
RB RUBBER, RUBBER BASE
RD ROOF DRAIN
REBAR REINFORCING BAR
RECEP RECEPTACLE, RECEPTION
REF REFERENCE
REFL REFLECTED
REFR REFRIGERATOR
REG REGULAR
REINF REINFORCED
REP REPAIR
REQ REQUIRE, REQUIRED
RESIL RESILIENT
REV REVISION
RFG ROOFING
RH RIGHT HAND
RL RAIN LEADER
RM ROOM
RO ROUGH OPENING
RT RIGHT
S SOUTH
SC SOLID CORE
SCHED SCHEDULE
SCUP SCUPPER
SD SOAP DISPENSER
SECT SECTION
SHT SHEET
SHWR SHOWER
SIM SIMILAR
SND SANITARY NAPKIN DISPENSER
SNR SANITARY NAPKIN RECEPTACLE
SP STAND PIPE
SPEC SPECIFICATION
SPM SINGLE PLY MEMBRANE
SS SERVICE SINK, STAINLESS STEEL
SSM SOLID SURFACE MATERIAL
ST STAINLESS
STL STEEL
STN STONE
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SV SHEET VINYL
SYS SYSTEM
T TREAD
T GL TEMPERED GLASS
T&G TONGUE & GROOVE
TB TOWEL BAR
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPERED, TEMPORARY
TERR TERRAZZO
THK THICK
TLT TOILET
TOC TOP OF CURB, TOP OF CONCRETE
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOSL TOP OF SLAB
TTD TOILET TISSUE DISPENSER
TWS THRU-WALL SCUPPER
TYP TYPICAL
UC UNDERCOUNTER, UNDERCUT
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
VB VAPOR BARRIER, VINYL BASE
VC VALVE CABINET
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VIN VINYL
VIT VITREOUS CHINA
VNR VENEER
VP VENT PIPE, VAPOR PROOF
VTR VENT THRU ROOF
VWC VINYL WALL COVERING
W WIDTH
W/ WITH
W/O WITHOUT
WAINS WAINSCOT
WB WOOD BASE
WC WALL COVERING, WATER CLOSET
WD WOOD
WG WIRE GLASS
WH WATER HEATER
WIN WINDOW
WPR WATERPROOFING
WPT WORK POINT
WR WATER RESISTANT, WASTE RECEPTACLE
WT WEIGHT
WWF WELDED WIRE FABRIC
ABBREVIATIONS
ABBRV FULL WORD
@ AT
A/C AIR CONDITIONING
AB ANCHOR BOLT
AC ACOUSTICAL
ACP ACOUSTICAL CEILING PANEL
AD ACCESS DOOR
ADJ ADJACENT, ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AL ALUMINUM
ALT ALTERNATE
AP ARMOR PLATE
APPROX APPROXIMATE
ARCH ARCHITECTURAL
AWC ACOUSTICAL WALL COVERING
BC BRICK COURSES(ING)
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BENCH MARK, BEAM
BOT BOTTOM
BRG BEARING
BRK BRICK
BSMT BASEMENT
BUR BUILT UP ROOFING
CB CATCH BASIN
CF CUBIC FOOT (FEET)
CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CFM CUBIC FOOT PER MINUTE
CG CORNER GUARD
CHAN CHANNEL
CHR CHAIR RAIL
CI CAST IRON
CIP CAST IN PLACE
CJ CONTROL JOINT
CLG CEILING
CLO CLOSET
CLR CLEAR
cm CENTIMETER
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
COMP COMPOSITION, COMPOSITE
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
CP CLEAR PLASTIC
CPT CARPET
CR CRASH RAIL
CR/BG CRASH RAIL / BUMPER GUARD
CT CERAMIC TILE
CTR CENTER
CV CHECK VALVE
CW CLEAR WIRE GLASS
CY CUBIC YARD
CYL CYLINDER
Ѥ CENTERLINE
D DEPTH
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIM DIMENSION
DISP DISPENSER
DIV DIVISION
DN DOWN
DP DAMPROOFING
DR DOOR, DRAIN
DS DOWNSPOUT
DWG DRAWING
DWGS DRAWINGS
EA EACH
EB EXPANSION BOLT
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATOR, ELEVATION
EMER EMERGENCY
ENGR ENGINEER(ING)
EPDM ETHYLENE PROPYLENE DIENE MONOMER (ROOF
MEMBRANE)
EQ EQUAL
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXPA EXPANSION ANCHOR
EXT EXTERIOR
F FAHRENHEIT
FA FIRE ALARM
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FHC FIRE HOSE CABINET
FIN FINISH(ED)
FO FINISHED OPENING
FOF FACE OF FINISH
FOS FACE OF STUD
FRTW FIRE RETARDANT TREATED WOOD
FV FIELD VERIFIED
FWC FABRIC WALL COVERING
GA GAGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GEN GENERAL
GL GLASS, GLAZING
GND GROUND
GNV GOOSE NECK VENTILATOR
GR GROUT
GYP GYPSUM
GYP BD GYPSUM BOARD
H HIGH
HB HOSE BIBB
HC HOLLOW CORE
HD HEAVY DUTY
HDW HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HRL HANDRAIL
HVAC HEATING VENTILATING & AIR CONDITIONING
HWD HARDWOOD
ID INSIDE DIAMETER
IN INCH
INSUL INSULATION
INT INTERIOR
IPT INTERIOR PAINT
JAN JANITOR
JCT JUNCTION
JST JOIST
JT JOINT
JT B JOINT BACKER
KB KEYBOARD
KIT KITCHEN
KO KNOCKOUT
KP KICK PLATE
KS KNEE SPACE
L LENGTH
LAM LAMINATE, LAMINATED
LAM GL LAMINATED GLASS
LAV LAVATORY
LB POUND
LBF POUNDS-FORCE
LH LEFT HAND
SHEET LAYOUT
GENERAL SYMBOLS
DRAWING NUMBERS
MAT ERIAL GRAPHICS
TOBACCO FREE WORKZONE NOTES
GENERAL NOTES
FIREPROOFING NOTES
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
SEALANT
UNFACED BATT INSULATION, MIN R-13
ALUMINUM STOREFRONT
SYSTEM
1" POLYMER-BASED EXTERIOR
INSULATION AND FINISHING SYSTEM
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
SHEATHING
SILL PAN WITH END DAMS
ON SEALANT BED
ALUMINUM STOREFRONT
SYSTEM
SEALANT
SHIM
ELASTOMERIC COATING
DRAINAGE FILL
SLOPE GRADE AWAY FROM
FOUNDATION 1/8"/FT MINIMUM
BACKER ROD AND
CONTINUOUS SEALANT
BACKER ROD AND
CONTINUOUS SEALANT
METAL FLASHING
SHIM
SEALANT
5/8" GYP BD
UNFACED BATT INSULATION, MIN R-13
ALUMINUM STOREFRONT
SYSTEM
BACKER ROD AND
CONTINUOUS SEALANT
BACKER ROD AND
CONTINUOUS SEALANT
1"
1" POLYMER-BASED EXTERIOR
INSULATION AND FINISHING SYSTEM
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
SHEATHING
7'-4"8'-0"1B
A.002
1A
A.002
1C
A.002
1/4" CLEARANCE FROM EDGE
OF PANEL TO FLASHING
"Z" FLASHING
FIBER CEMENT PANELS ON
PROPRIETARY CLIP SYSTEM
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED EXTERIOR
INSULATION. INSULATION
COMPRESSIVE STRENGTH OF 25 PSI
NEW SHEATHING
EXISTING WALL AND WINDOW TO
REMAIN. FIELD CONDITION MAY VARY.
GC TO VIF. REMOVE SHEATHING AND
EIFS FINISH AND PREPARE TO
RECEIVE NEW
PROVIDE BUG SCREEN AT EXPOSED
ENDS OF FIBER CEMENT PANEL
WALLS
EXIST WALL
METAL FLASHING
REMOVE EXISTING SEALANT,
SECURE FLASHING, AND
PROVIDE NEW SEALANT
FIBER CEMENT PANEL
FIBER CEMENT PANEL SPACER,
PROPRIETARY, REFERENCE
MANUFACTURER DETAILS
CONT INSULATION, EXIST
5/8" GYP BOARD SHEATHING, EXIST
NEW FLUID APPLIED VAPOR
PERMEABLE AIR BARRIER
PROPRIETARY CLIP SYSTEM,
REFERENCE MANUFACTURER DETAILS
DETAIL APPLIES TO EXISTING
WINDOWS WHERE FIBER
CEMENT PANELS ARE BEING
APPLIED TO THE HOSTING WALL.
PROPRIETARY SINGLE FLANGE
SEALANT BACKER, REFERENCE
MANUFACTURER DETAILS
SEALANT
"L" TRIM, PAINT FIBER CEMENT PANELS ON
PROPRIETARY CLIP SYSTEM
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED EXTERIOR
INSULATION. INSULATION
COMPRESSIVE STRENGTH OF 25 PSI
NEW SHEATHING
EXISTING WALL AND WINDOW TO
REMAIN. FIELD CONDITION MAY VARY.
GC TO VIF. REMOVE SHEATHING AND
EIFS FINISH AND PREPARE TO
RECEIVE NEW
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 12:14:04 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
WINDOW TYPES, FRAME
TYPES & SCHEDULE
05/14/2019 -
PERMIT SET
A.002
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE: 3" =1'-0"DRAWING REF: A.0021CSTOREFRONT -J AMB
DETAIL
SCALE: 3" =1'-0"DRAWING REF:A.0021ASTOREFRONT -SILL
DETAIL
SCALE: 3" =1'-0"DRAWING REF: A.0021BSTOREFRONT HEAD DETAIL
SCALE:1/4" = 1'-0" DRAWING REF: A.111 3A ELEVATION - STOREFRONT
SCALE:3" = 1'-0"DRAWING REF:A.402c2BEXISTINGWINDOW-HEAD
DETAIL
SCALE:3" = 1'-0"2A EXISTING WINDOW SILL DETAIL
SCALE: 3" =1'-0"2 C DETAIL -W IN DOW JAMB
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
DN
3 2 1
45 6
9 8 7
12 11 10
C2
C1
GREEN SCREEN
AERIAL VIEW
REAR PARKING
REAR ENTRY
VIEW - REAR PARKING VIEW FROM I280
PROPERTY BACKING UP TO INTERSTATE. VISIBILITY OF REAR ENTRANCES OBSCURED BY GREEN SCREEN FROM PUBLIC VIEW
VIEW FROM N. WOOLF RD
1
2
3
4 5 6
7
8
9
101112
C1C2
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 12:14:06 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
EXISTING CONDITIONS -
PHOTOGRAPHIC
DOCUMENTATION
05/14/2019 -
PERMIT SET
A.010
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
EXISTING CONDITIONS - PHOTOGRAPHIC DOCUMENTATION
EXISTING CONDITIONS - PHOTOGRAPHIC DOCUMENTATION - PROPERTY VISIBILITY PHOTOGRAPHIC DOCUMENTATION - KEY PLAN
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
DN
DN
ACCESSIBLE
ENTRANCE
ACCESSIBLE
ENTRANCE
ACCESSIBLE ENTRANCE
ACCESSIBLE
PARKING STALL
VAN ACCESSIBLE
PARKING STALL
ACCESSIBLE
PARKING STALL
VAN ACCESSIBLE
PARKING STALL
VAN ACCESSIBLE
PARKING STALL
VAN ACCESSIBLE
PARKING STALL
ACCESSIBLE PATH OF TRAVELACCESSIBLE PATH OF TRAVEL
ACCESSIBLE
PATH OF TRAVEL
ACCESSIBLE
PATH OF TRAVEL
ACCESSIBLE
PATH OF TRAVEL
ACCESSIBLE
PATH OF TRAVEL
ACCESSIBLE
PATH OF TRAVEL
PUBLIC RIGHT OF WAY/
PUBLIC SIDEWALK
(SIDWALK ELEVATION
MATCH ADJACENT
PARKING ELEVATION -
NO CURB RAMP
REQUIRED)
CURB RAMP
CURB RAMP
REFER TO
6B/A601
CURB RAMP
REFER TO 6B/A601
CURB RAMP
REFER TO
6B/A601
CURB RAMP
REFER TO 6B/A601
CURB RAMP
REFER TO 6B/A601
FEDERAL
YELLOW
TRUNCATED
DOMES
FEDERAL YELLOW
TRUNCATED
DOMES
FEDERAL YELLOW
TRUNCATED
DOMES
FEDERAL YELLOW
TRUNCATED
DOMES
FEDERAL YELLOW
TRUNCATED
DOMES
FEDERAL YELLOW
TRUNCATED DOMES
FEDERAL YELLOW
TRUNCATED DOMES
CURB RAMP
NOTE: RAISED CURBS
(+/-4") SEPARATE
SIDEWALKS FROM
VEHICULAR AREAS,
TYP.
PARKING COUNT:
TOTAL PARKING STALLS: 140
TOTAL ACCESSIBLE PARKING STALLS: 6
TOTAL VAN ACCESSIBLE PARKING STALLS: 4
REFER TO A601 FOR PARKING SPACE
DETAILS FOR STALL SIZE, MARKING, AND
SIGNAGE.
ACCESSIBLE
PATH OF TRAVEL
TO PUBLIC RIGHT
OF WAY/ PUBLIC
SIDEWALK
CURB RAMP
REFER TO
6B/A6012'-0" MINIMUM
FINE $250
INTERNATIONAL SYMBOL OF ACCESSIBILITY
IN WHITE ON A DARK BLUE BACKGROUND -
70 SQIN60" MIN2" DIA GALVANIZED
STEEL POST 24" INTO
GROUND BY HOTEL
OPERATIONS
ACCESSIBLE
PARKING
ACCESSIBLE ROUTE80 MIN. ATVAN
ACCESSIBLE
MIN.
17"22" MIN.1" LETTERING STATING
"UNAUTHORIZED" VEHICLES PARKED IN DESIGNATED
ACCESSIBLE SPACES NOT DISPLAYING
DISTINGUISHING PLACARDS OR SPECIAL LICENSE
PLATES ISSUED FOR PERSONS WITH DISABILITIES
WILL BE TOWED AWAY AT OWNER'S EXPENSE.
TOWED VEHICLES MAY BE RECLAIMED AT :
___________ OR BY TELEPHONING ______________."
BLANK SPACES SHALL BE FILLED IN WITH
APPROPRIATE INFORMATION AS A PERMANENT PART
OF THE SIGN
216" MINIMUM108" 96"
INTERNATIONAL SYMBOL
OF ACCESSIBILITY
36" BY 36" MIN.
BLUE LINES
HATCHED WHITE
LINES 36" ON
CENTER MAX.
NO PARKING
WHITE LETTERS
12" TALLEQ EQ
SIGNAGE REFER TO
4E/A.010
216" MINIMUM108" 60"
BLUE LINES
HATCHED WHITE
LINES 36" ON
CENTER MAX.
NO
PARKING
WHITE LETTERS
12" TALL
INTERNATIONAL SYMBOL
OF ACCESSIBILITY
36" BY 36" MIN.
EQ EQ
SIGNAGE REFER TO
4E/A.010
3'-0" SLOPE 1:12 MAXFOR 6'-0" +/- 4'-0" MIN.4'-0"
CROSS SLOPE OF 1:48
DETECTABLE
WARNINGS
2" 2"
BRUSH CONCRETE WITH
SLOPE OF 1:48 IN ALL
DIRECTIONS
BRUSH CONCRETE WITH
SLOPE OF 1:48 IN ALL
DIRECTIONS4'-0" MIN.COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 12:14:15 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
SITE PLAN -
ACCESSIBILITY
05/14/2019 -
PERMIT SET
A.011
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:1/16" = 1'-0"DRAWING REF: A.401b6ASITEPLAN- ACCESSIBILITY
SCALE: 1/2" =1'-0"4E VAN PARKING
SIGN
SITE PLAN -
ACCESSIBILITY AND
SITE ACCESSIBILITY
REQUIREMENTS.
WORK NOT IN SCOPE
FOR THIS DRAWING
SET. SITE PLAN FOR
REFEREN C E ONLY.
SCALE: 1/4" = 1'-0"3E VAN ACCESSIBLE PARKING DETAIL
SCALE: 1/4" = 1'-0"2E ACCESSIBLE PARKING DETAIL
SCALE:1/4" =1'-0"1 E CURB RAMP DETAIL
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 12:14:15 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
CONSTRUCTON
MANAGEMENT
PRACTICES
05/14/2019 -
PERMIT SET
A.012
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 3:29:25 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
CALGREEN
05/14/2019 -
PERMIT SET
A.013
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
DN
DN
30 TOTAL COURTYARD - GC TO VIF
26.56.19.A
18 TOTAL EXTERIOR - GC TO VIF
A.110
3E
10.14.00.C
10.14.00.C
PARKING COUNT:
TOTAL PARKING STALLS: 140 (NO CHANGE)
TOTAL ACCESSIBLE PARKING STALLS: 6 (NO CHANGE)
TOTAL VAN ACCESSIBLE PARKING STALLS: 4 (NO CHANGE)
REFER TO A.011 FOR ACCESSIBLE PARKING SPACE DETAILS
FOR STALL SIZE, MARKING, AND SIGNAGE.
4 BICYCLE PARKING STALLS PROVIDED
BUILDING AREA: 79,406 SQ.FT
PER CMC SECTION 1 9.1 24.040 - HOTEL = 20,000 SQ. FT / STALL
79,406 / 20,000 = 3,97 = 4 BICYCLE STALLS REQUIRED
149 GUESTROOMS (NO CHANGE)
18 NUMBER OF EMPLOYEES AT ANY GIVEN TIME
9'-0" TYP 25'-0" TYP18'-0" TYPPUBLIC RIGHT OF WAY/
PUBLIC SIDEWALK
N WOLFE ROAD
PUBLIC SIDEWALK
EXISTING CHAIN LINK FENCE TO
BE DEMOLISHED (+/-6' HIGH)
EXISTING TO REMAIN CHAIN
LINK FENCE (+/- 6' HIGH)
EXISTING TO REMAIN "DOG
EAR" WOOD PRIVACY FENCE
(+/- 6' HIGH)
EXISTING TO REMAIN "DOG
EAR" WOOD PRIVACY FENCE
(+/- 6' HIGH)
EXISTING TO REMAIN CHAIN
LINK FENCE (+/- 12' HIGH)
EXISTING TO REMAIN CHAIN
LINK FENCE (+/- 6' HIGH)
EXISTING TO REMAIN "DOG EAR"
WOOD PRIVACY FENCE (+/- 6' HIGH)
DRIVE
27'-10"DRIVE25'-0"DRI
VE24'
-8 1/4"
DRIVE
25'-7 1/2" 20'-0" 24'-0"
DRIVE
26'-6 3/4" DRIVE17'-3 1/2"DRIVE32'-7"1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
47 46 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68
89
88
87
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
72
71
70
69
73
74
75
76
77
78
79
80
81
82
83
84
85
86106107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132
133134
135
136
137
138
139
140
PARKING STALLS
NUMBERED FOR CLARITY
45
A.406
2A
NEW WASTE TRIO STATION
WITH CIGARETTE FILTER URN
ATTACHMENT
DRIVE24'-0"CB-8
CB-7
CB-6
CB-5
CB-4
NEW CURB CB-3
CB-2
CB-1
D
19'-2 3/4"15'-0"
PROPERTY LINE
D
EXISTING EASEMENT ABANDONED EASEMENT
D D
D
NEW FENCE
EXTENSION
D
03.30.00.A
10.14.00.B
4'-0"4'-0" 4'-0" 12'-0"4'-0"
10'-6 3/4"
BIKE RACK
4 BICYCLE STALLS 3'-0"10" MIN. 4" MIN. 1'-8"
9" MIN.2'-6"PROVIDE RELIANCE
FOUNDRY R-7906 POST &
RING BIKE BOLLARD
NEW 4" REINFORCED
CONCRETE SLAB, BROOM
FINISH
4" MIN, COMPACT
SUBGRADE
EXPANSION JOINT
EXISTING SIDE WALK
ALIGN
SLOPE TO DRAIN - GC
TO VIF DIRECTION OF
SLOPE IN FIELD
1/4" PER 12"
LEGEND: NEW TRASH CAPTURE SYSTEM
CB #1, REM TRITON BFTG-FTC FILTER DEVICES. (CONFIGURED WITH BIOFLEX
TRASH GUARD (BFTG) MEDIA CARTRIDGE STRATEGY)
TR24SR-D-FOG-BFTG-FTC DESIGNED FOR A 2' X 2' DROP CATCH BASIN
CB #2
CB #3, 4, 5, 6, 7, 8 REM TRITON BFTG-FTC FILTER DEVICES. (CONFIGURED WITH
BIOFLEX TRASH GUARD (BFTG) MEDIA CARTRIDGE STRATEGY.)
TR2448-TH-BFTG-FTC
CATCH BASIN ID -SEE PLAN CAPTURE DEVICE DESCRIPTION
NOTE: ALL STORM DRAIN INLETS TO BE MARKED WITH NEW "NO DUMPING - FLOWS TO CREEK" SIGNAGE
D
D
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:53:13 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
OVERALL PLANS - SITE
05/14/2019 -
PERMIT SET
A.110
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
KEYNOTES
03.30.00.A *ADD ALT* PROVIDE NEW 4" MIN. REINFORCED CONCRETE SLAB. BROOM
FINISH.
1 0.1 4.00.B *ADD ALT* PROVIDE "BICYCLE PARKING" SIGN
1 0.1 4.00.C SIGNAGE BY OTHERS.
26.56.1 9.A OFCI LIGHT BOLLARD. INSTALL IN EXISTING LIGHT BOLLARD LOCATION.
REFER TO ELECTRICAL DRAWINGS FOR DETAILS
NSWE100.00°
SCALE:1/16" =1'-0"DRAWING REF: -A.404a6AOVERALL
PLAN - SITE
SCALE: 1/8" = 1'-0" DRAWING REF: A.1103E
ADD ALT - ENLARGED PLAN
BICYCLE PARKING
SCALE: 1" = 1'-0"2E ADD ALT - BIKE RACK SECTION
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
C 1 1 /20/2 01 9 BUILDING PERMIT REVIEW -
REVISION #3
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
D
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
DN D DREF.DWOOOO
O O
OO
OO
OOOODDD
DODDD
DOA.201
A.201
A.201
A.201
4C
A.202
A.403a
1A
A.405
1A
A.403a
1C
A.401a
3A
A.402a
4A
A.405
1A SIM. MIR.
A.002 3A
A.203
6A
A.203
6B
A.203 4C
A.2034E
6B
3E3C A.204
6A
NO WORK IN THIS AREA
POCHE LEGEND
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:53:15 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
OVERALL PLANS - 1ST
FLOOR PLAN
05/14/2019 -
PERMIT SET
A.111
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:3/32" =1'-0"DRAWING REF:-A.404a6AOVERALL
PLAN -GROUND FLOOR
KEYNOTES
NSWE100.00°
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
D
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
A.201
A.201
A.201
A.201
4C
A.202
A.402a
6A
A.403a
5A
A.403a
5C
A.002 3A
A.401a
5A
A.203
6A
A.203
6B
A.203 4C
A.2034E
6B
3E3C A.204
6A
FULLY ADHERED, CONTINUOUS
TPO ROOF MEMBRANE
FULLY ADHERED, CONTINUOUS
TPO ROOF MEMBRANE
FULLY ADHERED, CONTINUOUS
TPO ROOF MEMBRANE
FULLY ADHERED, CONTINUOUS
TPO ROOF MEMBRANE
FULLY ADHERED, CONTINUOUS
TPO ROOF MEMBRANE
D
D
D
D
D
NO WORK IN THIS AREA
POCHE LEGEND
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:53:16 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
ROOF PLAN
05/14/2019 -
PERMIT SET
A.114
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
KEYNOTES
NSWE100.00°
SCALE: 3/32" = 1'-0"DRAWING REF: -A.404a6AOVERALLPLANS
-ROOF
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
D
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
4C
A.403c
09.91.13.A
09.91.13.A
26.56.19.B
09.91.13.A
EF-1
FC-1
EF-2
EF-2
EF-3
EF-3
EF-3
EF-1
EF-2
EF-1 EF-1EF-1
EF-1
EF-2EF-1 EF-2
EF-2
EF-1
TYP.
EF-4
EF-4
09.91.13.A
31.00.00.A NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 45'-6"NATURAL GRADE TO TOP OF PROPOSED PLATE33'-3 3/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 47'-6 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 33'-1 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 31'-8 1/2"MTL-2 AT UNDERSIDE
OF PORTE COCHERE &
CANOPYD 2'-0 3/4" (PARAPET)
D
D
09.91.13.A
09.91.13.A
09.91.13.A09.91.13.A
26.56.19.B
EF-2 EF-2EF-2
EF-3
EF-2 EF-2
FC-1
EF-3
EF-2
EF-2
EF-2
EF-2
EF-2
EF-2
EF-1
EF-1
EF-1
EF-1
EF-1EF-1
EF-2
EF-2
EF-2
EF-1 EF-1
EF-1
EF-1
EF-2
EF-1
EF-2
EF-2 EF-2 EF-2
EF-2 EF-1
EF-2EF-4
EF-4
09.91.13.A
NATURAL GRADE TO TOP OF PROPOSED PLATE31'-3 3/4" 31.00.00.ANATURAL GRADE TO TOP OF EXISTING PLATE+/- 27'-2 1/2"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 42'-8"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/2"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"MTL-2 AT UNDERSIDE
OF PORTE COCHERE &
CANOPY D2'-0 3/4" (PARAPET)
D
D
EF-2
TRASH ENCLOSURE
EF-2 @ TRASH ENCLOSURE
ROOF STRUCTURE
D
D
1A
A.402b
6A
A.402b
3C
A.402b
3A
A.402b
EF-1 EF-1FC-1
EF-3
EF-2 EF-2
EF-2
EF-2
EF-1
EF-2
EF-1 EF-1
EF-2
EF-2
FC-1
EF-3
EF-2
EF-2
EF-2 EF-2
4A
A.402b
09.91.13.A 09.91.13.A
09.91.13.A
09.91.13.A
EF-3
FC-1
EF-1 EF-1 EF-1EF-1 EF-1 EF-1 NATURAL GRADE TO TOP OF PORTE COCHERE+/- 13'-2"31.00.00.A NATURAL GRADE TO TOP OF PROPOSED PLATE+/- 22'-10"12'-10"MTL-2 AT UNDERSIDE
OF PORTE COCHERE
D
EF-2 @ TRASH ENCLOSURE WALLS,
GATE, & ROOF STRUCTURE
D
EF-1 EF-1 EF-1 EF-1 EF-2 EF-1EF-1 EF-1 EF-1 EF-2
EF-2 EF-2 EF-2
EF-1
EF-2
EF-2EF-2 EF-2
5A
A.405
5A
A.405
SIM
EF-2 EF-2 EF-4 EF-4 NATURAL GRADE TO TOP OF EXISTING PLATE+/- 12'-10 3/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 19'-3 3/4"31.00.00.A
EF-2
CEILING
EF-1
EF-2
EF-2 PERPENDICULAR
WALL
PERPENDICULAR
WALL
EF-1
EF-1
EF-1
CEILING
PERPENDICULAR
WALL
NOTE: AT LOCATIONS
WHERE OUTSIDE
FACE OF BALCONY
WALL (PARKING LOT
FACING) ARE
INDICATED TO BE
PAINTED EF-2, ALL
LOCATIONS
INDICATED TO BE
PAINTED EF-1 IN THIS
VIEW ARE TO BE
PAINTED EF-2
EF-1
CEILING
EF-1
CEILING
EF-1
EF-1
PERPENDICULAR
WALL
PERPENDICULAR
WALL
EF-1
EF-1
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:53:21 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
EXTERIOR ELEVATIONS
05/14/2019 -
PERMIT SET
A.201
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
C OU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
KEYNOTES
09.91.13.A PAINT EXISTING TO REMAIN EIFS - REFER TO ELEVATIONS FOR COLORS.
PAINT TRIMS, FASCIA, GUTTERS, RAIN LEADERS, HANDRAILS, GUARDRAIL,
PTAC COVERS - MATCH ADJACENT EIFS WALL FINISH.
26.56.1 9.B OFCI EXTERIOR GRADE SCONE LIGHT. INSTALL IN EXISTING LIGHT
LOCATION. REFER TO ELECTRICAL DRAWINGS FOR DETAILS
31.00.00.A NATURAL GRADE - AS PER GRADING PLAN DATED 10/25/86 BY SANDIS AND
ASSOCIATES INC. ENGINEERS, SURVEYORS AND PLANNERS
SCALE:3/32" = 1'-0"DRAWING REF: A4106AELEVATION -EAST
SCALE:3/32" = 1'-0"DRAWING REF: A.1116BELEVATION -WEST
SCALE:3/32" = 1'-0"DRAWING REF: A.1114CELEVATION -NORTH
SCALE:3/32" = 1'-0"DRAWING REF: A.1114EELEVATION -SOUTH
TYP.
SCALE:3/32" = 1'-0"6C ELEVATION - JACUZZY
SCALE: 3/32" = 1'-0" 5C
ELEVATION - TYPICAL SIDE WALL
AT BALCONIES WITH WING WALLS
EXTERIOR FINISH LEGEND
FINISH NO. MATERIAL MANUFACTURER STYLE NAME / NO. COLOR SIZE DESCRIPTION / REMARKS
DRY STONE
ST-01 DRY STONE HERITAGE STONE EIRE DRY STACK PROVIDE SAMPLE FOR FINAL
APPROVAL BY
ARCHITECT/MARRIOTT
FIBER CEMENT WALL PANEL
FC-1 FIBER CEMENT WALL
PANEL
NICHIHA VINTAGE WOOD CEDAR 18" x 10' x 5/8" W/ TAMLYN COORDINATED
TRIM
METAL CEILING PANEL
MTL-2 METAL CEILING PANEL PAC-CLAD FLUSH SOLID WALL
PANEL
DARK BRONZE 12" CEILING OF PORTE COCHERE
AND FRONT ENTRANCE
CANOPY
PAINT
EF-1 PAINT SHERWIN WILLAIMS SNOWBOUND SW 7004
EF-2 PAINT BENJAMIN MOORE HEARTSONE SW 1601
EF-3 PAINT BENJAMIN MOORE GRAPHITE 1603
PT-3 PAINT SHERWIN WILLAIMS FIRETEX FX5090 TO MATCH PAC-CLAD
DARK BRONZE
EGGSHELL FOR (4) EXPOSED
STEEL COLUMNS AND (2)
EXPOSED BEAMS @ PORTE
COCHERE
PT-4 PAINT SHERWIN WILLAIMS PRO-INDUSTRIAL
PRE-CATYLYZED WATER
BASED EPOXY
TRICORN BLACK SW 6258 EXTERIOR RAILINGS
PT-5 PAINT SHERWIN WILLAIMS PRO-INDUSTRIAL
PRE-CATYLYZED WATER
BASED EPOXY
TO MATCH POR-CLAD
DARK BRONZE
CANOPY SOFFIT
EF-4 PAINT SHERWIN WILLIAMS PORTABELLO SW6102
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
C 1 1 /20/2 01 9 BUILDING PERMIT REVIEW -
REVISION #3
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
D
D
D
D
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
09.91.13.A
EF-1
EF-4 EF-1
EF-2EF-2
EF-1
EF-2
EF-1
EF-2
EF-1 EF-1
EF-1
EF-3
EF-1EF-1
26.56.19.B
TYP.NATURAL GRADE TO TOP OF PROPOSED PLATE+/- 33'-4 1/4"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 42'-8"NATURAL GRADE TO TOP OF PROPOSED PLATE+/- 21'-8 1/2"31.00.00.ANATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/2"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"44'-11"09.91.13.A
09.91.13.A 09.91.13.A
EF-2 EF-2EF-2
EF-2EF-2 EF-2
EF-2
EF-1
NATURAL GRADE TO TOP OF EXISTING PLATE+/- 11'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 18'-0 1/2"31.00.00.A
09.91.13.A
09.91.13.A
09.91.13.A EF-2
EF-2
EF-1
EF-1
EF-1
EF-1
EF-2
EF-1
26.56.19.B 26.56.19.B 26.56.19.B NATURAL GRADE TO TOP OF EXISTING PLATE+/- 12'-8"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 22'-10 1/2"31.00.00.A
4C
A.403c
2C
A.403c
09.91.13.A
EF-3
EF-1
EF-1
EF-1 EF-2
EF-1 EF-2 EF-1
EF-1 EF-1 EF-1 EF-4
EF-2EF-2 EF-2
EF-2
EF-1
26.56.19.B
TYP.NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 27'-2 1/2"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 43'-6"NATURAL GRADE TO TOP OF PROPOSED PLATE+/- 33'-4 1/4"31.00.00.A 44'-11"MTL-2 AT UNDERSIDE OF
PORTE COCHERE & CANOPY
D
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:53:24 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
EXTERIOR ELEVATIONS -
COURTYARD
05/14/2019 -
PERMIT SET
A.202
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:3/32" = 1'-0"DRAWING REF: A.1116BELEVATION -WEST COURTYARD
SCALE:3/32" = 1'-0"DRAWING REF: A4233EELEVATION -SOUTH COURTYARD
SCALE:3/32" = 1'-0"DRAWING REF: A.1113CELEVATION -NORTH COURTYARD
SCALE:3/32" = 1'-0"DRAWING REF: A.1116AELEVATION -EAST COURTYARD
KEYNOTES
09.91 .1 3.A PAINT EXISTING TO REMAIN EIFS - REFER TO ELEVATIONS FOR COLORS.
PAINT TRIMS, FASCIA, GUTTERS, RAIN LEADERS, HANDRAILS, GUARDRAIL,
PTAC COVERS - MATCH ADJACENT EIFS WALL FINISH.
2 6.56.1 9.B OFCI EXTERIOR GRADE SCONE LIGHT. INSTALL IN EXISTING LIGHT
LOCATION. REFER TO ELECTRICAL DRAWINGS FOR DETAILS
31 .00.00.A NATURAL GRADE - AS PER GRADING PLAN DATED 10/25/86 BY SANDIS AND
ASSOCIATES INC. ENGINEERS, SURVEYORS AND PLANNERS
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
C 1 1 /20/2 01 9 BUILDING PERMIT REVIEW -
REVISION #3
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
D
D
D
D
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
EF-1 EF-1 EF-1 EF-1 EF-2 EF-1EF-1 EF-1 EF-1 EF-2
EF-2 EF-2 EF-2
EF-1
EF-2
EF-2EF-2 EF-2
EF-2 EF-2 EF-4 EF-4
EF-1 EF-1FC-1
EF-3
EF-2 EF-2
EF-2
EF-2
EF-1
EF-2
EF-1 EF-1
EF-2
EF-2
FC-1
EF-3
EF-2
EF-2
EF-2 EF-2
EF-3
FC-1
EF-1 EF-1 EF-1EF-1 EF-1 EF-1 MTL-2 AT UNDERSIDE OF
PORTE COCHERE & CANOPY
D
EF-2 @ TRASH ENCLOSURE WALLS,
GATE, & ROOF STRUCTURE
D
EF-1
FC-1
EF-2
EF-2
EF-3
EF-3
EF-3
EF-1
EF-2
EF-1 EF-1EF-1
EF-1
EF-2EF-1 EF-2
EF-2
EF-1
TYP.
EF-4
EF-4
MTL-2 AT UNDERSIDE OF
PORTE COCHERE & CANOPY
D
EF-2 EF-2EF-2
EF-3
EF-2 EF-2
FC-1
EF-3
EF-2
EF-2
EF-2
EF-2
EF-2
EF-2
EF-1
EF-1
EF-1
EF-1
EF-1EF-1
EF-2
EF-2
EF-2
EF-1 EF-1
EF-1
EF-1
EF-2
EF-1
EF-2
EF-2 EF-2 EF-2
EF-2 EF-1
EF-2EF-4
EF-4
MTL-2 AT UNDERSIDE OF
PORTE COCHERE & CANOPY
D
EF-2
TRASH ENCLOSURE
EF-2 @ TRASH ENCLOSURE
ROOF STRUCTURE
D
D
ST-1
FC-1
EF-4
EF-3
EF-2
EF-1
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:53:32 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
EXTERIOR ELEVATIONS,
COLOR
05/14/2019 -
PERMIT SET
A.203
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:3/32" = 1'-0"DRAWING REF: A.1114EELEVATION -SOUTH -COLOR
SCALE:3/32" = 1'-0"DRAWING REF: A.1114CELEVATION -NORTH -COLOR
SCALE:3/32" = 1'-0"DRAWING REF:A4106AELEVATION -EAST -COLOR
SCALE:3/32" = 1'-0"DRAWING REF:A.1116BELEVATION -WEST -COLOR
EXTERIOR COLOR FINISH LEGENDEXTERIOR FINISH LEGEND
FINISH NO. MATERIAL MANUFACTURER STYLE NAME / NO. COLOR SIZE DESCRIPTION / REMARKS
DRY STONE
ST-01 DRY STONE HERITAGE STONE EIRE DRY STACK PROVIDE SAMPLE FOR FINAL
APPROVAL BY
ARCHITECT/MARRIOTT
FIBER CEMENT WALL PANEL
FC-1 FIBER CEMENT WALL
PANEL
NICHIHA VINTAGE WOOD CEDAR 18" x 10' x 5/8" W/ TAMLYN COORDINATED
TRIM
METAL CEILING PANEL
MTL-2 METAL CEILING PANEL PAC-CLAD FLUSH SOLID WALL
PANEL
DARK BRONZE 12" CEILING OF PORTE COCHERE
AND FRONT ENTRANCE
CANOPY
PAINT
EF-1 PAINT SHERWIN WILLAIMS SNOWBOUND SW 7004
EF-2 PAINT BENJAMIN MOORE HEARTSONE SW 1601
EF-3 PAINT BENJAMIN MOORE GRAPHITE 1603
PT-3 PAINT SHERWIN WILLAIMS FIRETEX FX5090 TO MATCH PAC-CLAD
DARK BRONZE
EGGSHELL FOR (4) EXPOSED
STEEL COLUMNS AND (2)
EXPOSED BEAMS @ PORTE
COCHERE
PT-4 PAINT SHERWIN WILLAIMS PRO-INDUSTRIAL
PRE-CATYLYZED WATER
BASED EPOXY
TRICORN BLACK SW 6258 EXTERIOR RAILINGS
PT-5 PAINT SHERWIN WILLAIMS PRO-INDUSTRIAL
PRE-CATYLYZED WATER
BASED EPOXY
TO MATCH POR-CLAD
DARK BRONZE
CANOPY SOFFIT
EF-4 PAINT SHERWIN WILLIAMS PORTABELLO SW6102
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
D
D
D
D
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
EF-1
EF-4 EF-1
EF-2EF-2
EF-1
EF-2
EF-1
EF-2
EF-1 EF-1
EF-1
EF-3
EF-1EF-1
TYP.
EF-2 EF-2EF-2
EF-2 EF-2 EF-2
EF-2
EF-1
EF-2
EF-2
EF-1
EF-1
EF-1
EF-1
EF-2
EF-1
EF-3
EF-1
EF-1
EF-1 EF-2
EF-1 EF-2 EF-1
EF-1 EF-1 EF-1 EF-4
EF-2EF-2 EF-2
EF-2
EF-1
TYP.
MTL-2 AT UNDERSIDE OF
PORTE COCHERE & CANOPY
D
ST-1
FC-1
EF-4
EF-3
EF-2
EF-1
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:53:42 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
EXTERIOR ELEVATIONS -
COURTYARD, COLOR
05/14/2019 -
PERMIT SET
A.204
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:3/32" = 1'-0"DRAWING REF: A.1116BELEVATION -EAST COURTYARD, COLOR
SCALE:3/32" = 1'-0"DRAWING REF: A4233EELEVATION -SOUTH COURTYARD, COLOR
SCALE:3/32" = 1'-0"DRAWING REF: A.1113CELEVATION -NORTH COURTYARD, COLOR
SCALE:3/32" = 1'-0"DRAWING REF: A.1116AELEVATION -WEST COURTYARD, COLOR
EXTERIOR COLOR FINISH LEGENDEXTERIOR FINISH LEGEND
FINISH NO. MATERIAL MANUFACTURER STYLE NAME / NO. COLOR SIZE DESCRIPTION / REMARKS
DRY STONE
ST-01 DRY STONE HERITAGE STONE EIRE DRY STACK PROVIDE SAMPLE FOR FINAL
APPROVAL BY
ARCHITECT/MARRIOTT
FIBER CEMENT WALL PANEL
FC-1 FIBER CEMENT WALL
PANEL
NICHIHA VINTAGE WOOD CEDAR 18" x 10' x 5/8" W/ TAMLYN COORDINATED
TRIM
METAL CEILING PANEL
MTL-2 METAL CEILING PANEL PAC-CLAD FLUSH SOLID WALL
PANEL
DARK BRONZE 12" CEILING OF PORTE COCHERE
AND FRONT ENTRANCE
CANOPY
PAINT
EF-1 PAINT SHERWIN WILLAIMS SNOWBOUND SW 7004
EF-2 PAINT BENJAMIN MOORE HEARTSONE SW 1601
EF-3 PAINT BENJAMIN MOORE GRAPHITE 1603
PT-3 PAINT SHERWIN WILLAIMS FIRETEX FX5090 TO MATCH PAC-CLAD
DARK BRONZE
EGGSHELL FOR (4) EXPOSED
STEEL COLUMNS AND (2)
EXPOSED BEAMS @ PORTE
COCHERE
PT-4 PAINT SHERWIN WILLAIMS PRO-INDUSTRIAL
PRE-CATYLYZED WATER
BASED EPOXY
TRICORN BLACK SW 6258 EXTERIOR RAILINGS
PT-5 PAINT SHERWIN WILLAIMS PRO-INDUSTRIAL
PRE-CATYLYZED WATER
BASED EPOXY
TO MATCH POR-CLAD
DARK BRONZE
CANOPY SOFFIT
EF-4 PAINT SHERWIN WILLIAMS PORTABELLO SW6102
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
C 1 1 /20/2 01 9 BUILDING PERMIT REVIEW -
REVISION #3
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
D
D
D
D
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
6B
D.301
02.41.19.63
02.41.19.52
02.41.19.52
02.41.19.63
02.41.19.69
02.41.19.69
02.41.19.69
02.41.19.69
02.41.19.53
02.41.19.69
02.41.19.53
NATURAL GRADE TO TOP OF EXISTING PLATE+/- 12'-10 3/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 19'-3 3/4"31.00.00.A
EF-1 EF-1 EF-1 EF-1 EF-2 EF-1EF-1 EF-1 EF-1 EF-2
EF-2 EF-2 EF-2
EF-1
EF-2
EF-2EF-2 EF-2
EF-2 EF-2 EF-4 EF-4
EF-2 EF-2EF-2
EF-3
EF-2 EF-2
FC-1
EF-3
EF-2
EF-2
EF-2
EF-2
EF-2
EF-2
EF-1
EF-1
EF-1
EF-1
EF-1EF-1
EF-2
EF-2
EF-2
EF-1 EF-1
EF-1
EF-1
EF-2
EF-1
EF-2
EF-2 EF-2 EF-2
EF-2 EF-1
EF-2EF-4
EF-4
MTL-2 AT UNDERSIDE OF
PORTE COCHERE & CANOPY
D
EF-2
TRASH ENCLOSURE
D
EF-2 @ TRASH ENCLOSURE
ROOF STRUCTURE
D
3B
D.301
2B
D.301
02.41.19.67
02.41.19.51
02.41.19.53
02.41.19.51
02.41.19.50
02.41.16.01
02.41.19.52
02.41.19.69
26.56.19.B
02.41.19.63
02.41.19.69
02.41.19.69
02.41.19.69
02.41.19.65 TYP.
02.41.19.69
NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 42'-8"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/2"NATURAL GRADE TO TOP OF ROOF RIDGE TO BE DEMOLISHED+/- 32'-3 1/2"NATURAL GRADE TO TOP OF EXISTING / TO BE DEMOLSIHED PLATE+/- 27'-2 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 11'-10 3/4"NATURAL GRADE TO TOP OF PORTE COCHERE ROOF RIDGE TO BE DEMOLISHED+/- 18'-4 3/4"31.00.00.A
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:53:48 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
ELEVATIONS - EXISTING
& PROPOSED
05/14/2019 -
PERMIT SET
A.211
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
C 1 1 /20/2 01 9 BUILDING PERMIT REVIEW -
REVISION #3
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
SCALE:3/32" = 1'-0"DRAWING REF:xG0021 DEMOLITION ELEVATION - SOUTH
SCALE:3/32" = 1'-0"DRAWING REF:xG0022 ELEVATION SOUTH,COLOR
SCALE:3/32" = 1'-0"DRAWING REF:A.4063ELEVATION -WEST,COLOR
SCALE:3/32" = 1'-0"DRAWING REF:A.4064DEMOLITIONELEVATION - WEST
D
D
D
D
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
EF-1 EF-1FC-1
EF-3
EF-2 EF-2
EF-2
EF-2
EF-1
EF-2
EF-1 EF-1
EF-2
EF-2
FC-1
EF-3
EF-2
EF-2
EF-2 EF-2
EF-3
FC-1
EF-1 EF-1 EF-1EF-1 EF-1 EF-1 MTL-2 AT UNDERSIDE OF
PORTE COCHERE & CANOPY
D
EF-2 @ TRASH ENCLOSURE WALLS,
GATE, & ROOF STRUCTURE
D
2A
D.301
4A
D.301
02.41.19.67
02.41.19.52
02.41.19.51
02.41.19.69
02.41.19.51
02.41.16.01 02.41.19.56 02.41.19.52
02.41.19.66
02.41.19.68
02.41.19.67
02.41.19.51
02.41.19.53
02.41.19.69 02.41.19.69
02.41.19.69
02.41.19.52
NATURAL GRADE TO TOP OF PLATE OF PORTE COCHERE TO BE DEMOLISHED+/- 11'-10 3/4"NATURAL GRADE TO TOP OF PORTE COCHERE ROOF RIDGE TO BE DEMOLISHED+/- 18'-5 1/4"NATURAL GRADE TO TOP OF EXISTINGPLATE TO BE DEMOLISHED+/- 13'-10 3/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE TO BE BUILD OVER+/- 23'-10 3/4"31.00.00.A
02.41.19.63
02.41.19.52
02.41.19.67
02.41.19.51
02.41.19.53
02.41.19.51
02.41.16.01
02.41.19.50
02.41.19.69
02.41.19.69
02.41.19.69
02.41.19.65
02.41.19.71
TYP.
02.41.19.69
NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 45'-6"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 31'-8 1/2"NATURAL GRADE TO TOP OF PLATE TO BE DEMOLISHED+/- 29'-2 1/2"NATURAL GRADE TO TOP OF PLATE TO BE DEMOLISHED+/- 12'-10 3/4"NATURAL GRADE TO TOP OF PORTE COCHERE ROOF RIDGE TO BE DEMOLISHED+/- 19'-4 3/4"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 33'-1 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 47'-6 1/2"31.00.00.A
EF-1
FC-1
EF-2
EF-2
EF-3
EF-3
EF-3
EF-1
EF-2
EF-1 EF-1EF-1
EF-1
EF-2EF-1 EF-2
EF-2
EF-1
TYP.
EF-4
EF-4
MTL-2 AT UNDERSIDE OF
PORTE COCHERE & CANOPY
D
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:54:02 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
ELEVATIONS - EXISTING
& PROPOSED
05/14/2019 -
PERMIT SET
A.212
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
C 1 1 /20/2 01 9 BUILDING PERMIT REVIEW -
REVISION #3
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
SCALE:3/32" = 1'-0"DRAWING REF:A.401a1 ELEVATION -NORTH,COLOR
SCALE:3/32" = 1'-0"DRAWING REF:A.401a2 DEMOLITION ELEVATION -NORTH
SCALE:3/32" = 1'-0"DRAWING REF:A4103DEMOLITIONELEVATION - EAST
SCALE:3/32" = 1'-0"DRAWING REF:A4104ELEVATION -EAST,COLOR
D
D
D
D
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
02.41.19.69 02.41.19.69 02.41.19.69
NATURAL GRADE TO TOP OF EXISTING PLATE+/- 11'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 18'-0 1/2"EF-2 EF-2EF-2
EF-2 EF-2 EF-2
EF-2
EF-1
02.41.19.63
02.41.19.69
02.41.19.69
02.41.19.65
02.41.19.52
02.41.19.67
02.41.19.51
02.41.19.50
02.41.16.01
02.41.19.5102.41.19.6502.41.19.65
02.41.19.6502.41.19.65
02.41.19.65
02.41.19.65
02.41.19.65
02.41.19.52
TYP.TYP.TYP.
02.41.19.69
31.00.00.ANATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/2"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 42'-8"EF-1
EF-4 EF-1
EF-2EF-2
EF-1
EF-2
EF-1
EF-2
EF-1 EF-1
EF-1
EF-3
EF-1EF-1
TYP.
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:54:10 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
ELEVATIONS - EXISTING
& PROPOSED
05/14/2019 -
PERMIT SET
A.213
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
C 1 1 /20/2 01 9 BUILDING PERMIT REVIEW -
REVISION #3
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
SCALE:3/32" = 1'-0"DRAWING REF:A4231 DEMOLITION ELEVATION - SOUTH COURTYARD
SCALE:3/32" = 1'-0"DRAWING REF: A4232 ELEVATION -SOUTH COURTYARD, COLOR
SCALE:3/32" = 1'-0"DRAWING REF:A0063DEMOLITIONELEVATION - WEST COURTYARD
SCALE:3/32" = 1'-0"DRAWING REF: A.402a4ELEVATION -WEST COURTYARD, COLOR
D
D
D
D
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
02.41.19.69
02.41.19.6902.41.19.69
02.41.19.6502.41.19.65 02.41.19.65
02.41.19.69
TYP.NATURAL GRADE TO TOP OF EXISTING PLATE+/- 12'-8"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 22'-10 1/2"EF-2
EF-2
EF-1
EF-1
EF-1
EF-1
EF-2
EF-1
5B
D.301
02.41.16.01
02.41.19.50
02.41.19.51
02.41.19.53
02.41.19.66
02.41.19.51
02.41.19.67
02.41.19.69
02.41.19.69 02.41.19.63
02.41.19.65
02.41.19.65 02.41.19.65
02.41.19.65
02.41.19.65
02.41.19.65
TYP.
TYP.
02.41.19.69
02.41.19.52
NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 27'-2 1/2"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 43'-6"EF-3
EF-1
EF-1
EF-1 EF-2
EF-1 EF-2 EF-1
EF-1 EF-1 EF-1 EF-4
EF-2EF-2 EF-2
EF-2
EF-1
TYP.
MTL-2 AT UNDERSIDE OF
PORTE COCHERE & CANOPY
D
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:54:18 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
ELEVATIONS - EXISTING
& PROPOSED
05/14/2019 -
PERMIT SET
A.214
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
C 1 1 /20/2 01 9 BUILDING PERMIT REVIEW -
REVISION #3
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
SCALE:3/32" = 1'-0"DRAWING REF:D.1111 DEMOLITION ELEVATION - NORTH COURTYARD
SCALE:3/32" = 1'-0"DRAWING REF: xG0022 ELEVATION -NORTH COURTYARD, COLOR
SCALE:3/32" = 1'-0"DRAWING REF:A.401a3DEMOLITIONELEVATION - EAST COURTYARD
SCALE:3/32" = 1'-0"DRAWING REF: A.401a4ELEVATION -EAST COURTYARD, COLOR
D
D
D
D
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
5A
A.401b
3A
A.401b
2'-4" 24'-7" 2'-4"
29'-3" 7'-11" 1'-8"2'-4"21'-8" 2'-4"5C
A.402b
SIM
A.401b 5C
EQ EQ EQ EQ
EQ EQ EQ EQ26'-4"3A
A.401c
2A
A.401c
5A
A.401c
EQ EQALIGN
PORTE COCHERE
EDGE OF ROOF
ABOVE
EDGE OF SOFFIT
ABOVE
PORTE COCHERE
EDGE OF ROOF
ABOVE
CONCRETE
PLANTER,
REFERENCE
STRUCTURAL
DRAWINGS
NEW PORTE COCHERE PAVEMENT
NEW CONCRETE PAD, SUNDEK-CLASSIC
TEXTURE DECORATIVE CONCRETE
APPLICATION w/ CUSTOM 1'-0" LINEAR BANDS.
COLOR: PEWTER GRAY,
SLOPE NOT TO EXCEED 1:50 IN ALL
DIRECTIONS
NEW SIDEWALK
AND CURB
PORTE COCHERE
EDGE OF ROOF
ABOVE
EDGE OF LOW
ROOF ABOVE
6C
A.401a
6A
A.401c
A.401a
4C
5A
A.401b
5C
A.402b
3'-9"11'-1 1/4" 12'-1 1/4" 1 6'-1 1 1/4"
3A
A.401b
26'-11 1/2"EQ. EQ. EQ. 6'-0" 6'-0" 6'-0" EQ.EQ. 8'-4" EQ.EQ. 6'-4" EQ.1 '-1 1 " 7'-0"
4'-7" 26'-1 1 " 3'-11 3/4"
35'-6"1'-5 3/4" 24'-0" 1'-5 3/4"11 3/4" 9'-1 1/4" 1'-8" 5'-2 1/4"EQEQ (TYP 10 AT PORTE COCHERE)
26.56.20
C PT-05
C PT-05 26.56.20
(TYP 4 AT VESTIBULE)
5C
A.401c
SIM
6C
A.401c
5A
A.401b
3A
A.401b
SLOPE 1/4":1'-0" MINSLOPE1/4":1'-0" MINA.401b 5C
6C
A.401c
4" THICK 3,000 PSI
CONCRETE PAVING, W/
6X6X10/10 WELDED WIRE
FABRIC
TYP. COMPACTED
SUBGRADE
EXISTING ASPHALT PAVING
ALIGN
SUNDEK-CLASSIC TEXTURE DECORATIVE
CONCRETE APPLICATION w/ CUSTOM 1'-0"
LINEAR BANDSCOLOR: PEWTER GRAY
4" THICK 3,000 PSI
CONCRETE PAVING, W/
6X6X10/10 WELDED WIRE
FABRIC
TYP. COMPACTED
SUBGRADE
EXISTING ASPHALT PAVING
ALIGN
SUNDEK-CLASSIC TEXTURE DECORATIVE
CONCRETE APPLICATION w/ CUSTOM 1'-0"
LINEAR BANDS. COLOR: PEWTER GRAY
SLOPE NOT TO
EXCEED 1:50 IN ALL
DIRECTIONS
SQUARE CAST IRON
ROOF DRAIN AND
OVERFLOW DRAIN,
SECURE TO
STRUCTURAL
COLUMN, PAINT
WITH INTUMESCENT
PAINT, PT-3
EXPOSED
STRUCTURAL STEEL,
REFERENCE
STRUCTURAL
DRAWINGS, PAINT
WITH INTUMESCENT
PAINT, PT-3
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 12:14:51 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
ENLARG ED PORTE
COCHERE PLANS,
REFLECTED CEILING
PLANS & ROOF PLANS
05/14/2019 -
PERMIT SET
A.401a
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
KEYNOTES
26.56.20 NEW EXTERIOR RECESSED LIGHT. REFERENCE ELECTRICAL DRAWINGS.
SCALE:1/4" = 1'-0"DRAWING REF: A.1113AENLARGEDPLAN-PORTE
COCHERE
SCALE:1/4" = 1'-0"DRAWING REF:A.401b3CENLARGEDREFLECTEDCEILING PLAN - PORTE COCHERE
SCALE:1/4" = 1'-0"DRAWING REF:A.1145AENLARGEDROOFPLAN- PORTE COCHERE
SCALE:6E PERSPECTIVE
SCALE: 1 1/2" = 1'-0"DRAWING REF: A.401a6CDETAIL-PORTE
COCHERE PAVEMENT
SCALE: 3" =1'-0"DRAWING REF:A.401a4CDETAIL- PLAN -PORTE
COCHERE
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
1'-6"11'-4" A.401c
3C
A.401c
4C
1st Floor
A.401c
2C
GROUND SLOPE MAY VARY
CONCRETE
PLANTER,
REFERENCE
STRUCTURAL
DRAWINGS
GROUND
SLOPE MAY
VARY
3RD FLOOR
18' - 7"
2ND FLOOR
9' - 3"
1 ST FLOOR
0' - 0"
A.402c
5E SIM
A.402c
3C SIM
12'-10"3'-6"19'-0" 22'-6"1st Floor
1 /4" / 1'-0" MI N
22.14.28.A
+/- 9'-0"CL
1/4" / 1'-0" MIN
3RD FLOOR
18' - 7"
2ND FLOOR
9' - 3"
1 ST FLOOR
0' - 0"1'-6"11'-4" 2'-2 1/4"9'-1 3/4" 3A
A.401b
3A
A.401c
2A
A.401c 1'-6"11'-4" 2'-2 1/4"9'-1 3/4" 1/8"9'-1 5/8" COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 12:14:54 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
ENLARG ED PORTE
COCHERE SECTIONS
AND ELEVATIONS
05/14/2019 -
PERMIT SET
A.401b
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
KEYNOTES
22.14.28.A PRIMARY ROOF DRAIN. CONCEAL PRIMARY ROOF DRAIN IN ROOF
ASSEMBLY. CONNECT TO UNDERGROUND STORM/SEVER RUNOFF SYSTEM.
WHEN POSSIBLE LOCATE TO EXISTING LOCATION FROM DEMOLISHED
DOWNSPOUT
SCALE: 1/4" = 1'-0"DRAWING REF:A.401a3APORTECOCHERE-SECTION
SCALE: 1/4" = 1'-0"DRAWING REF:A.401a 5A PORTE COCHERE -SECTION
SCALE: 1/4" = 1'-0"DRAWING REF:A.402a3CPORTECOCHERE-SIDE
ELEVATION
SCALE: 1/4" = 1'-0"DRAWING REF:A.401a5CPORTECOCHERE-FRON T
ELEVATION
SCALE: 1/4" = 1'-0"3D PORTE COCHERE -SIDE ELEVATION@
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
BACKER ROD AND CONTINUOUS
SEALANT, PER PANEL REQ.
METAL PANEL SYSTEM ON
CARRIER
DRIP EDGE
PT WD BLOCKING
METAL WRAP DARK
BRONZE FINISH
5/8" DENSGLASS
SHEATHING
MEMB FLASH
COATED MET DRIP
EDGE
FASTNER 4" OC
STAGGERED
CONT 2x6 PT WD
NAILER SHIM AS REQ
RIGID INSULATION -
1 1/2" MIN.
MEMB. ROOFING - EXTEND
OVER EDGE OF BUILDING
VARIES1'-2 3/8"6" MIN.TAPERED RIGID INSULATION -1 .5" MIN
FULLY ADHERED, CONTINUOUS TPO ROOF MEMBRANE
FIBER CEMENT PANEL ON
PROPRIETARY CLIP SYSTEM
1" POLYMER-BASED EXTERIOR INSULATION.
INSULATION COMPRESSIVE STRENGTHS OF 25
PSI MIN.
NEW FLUID-APPLIED VAPOR PERMEABLE AIR
BARRIER
5/8" DENSGLASS SHEATHING
3/4" PLYWOOD SHEATHING
UNFACED BATH INSULATION R-19 MIN
EXISTING VESTIBULE WALLS
& SOFFIT - EXTEND TO
UNDERSIDE OF DECK
REPAIR EXISTING FINISHES
AS REQUIRED.
METAL PANEL SYSTEM
ON CARRIER
EXISTING TO REMAIN
STOREFRONT
BACKER ROD AND
CONTINUOUS SEALANT, PER
PANEL REQ.
PROVIDE BUG SCREEN AT EXPOSED
ENDS OF FIBER CEMENT PANEL WALLS
EXISTING WALL TO REMAIN. REMOVE
SHEATHING AND EIFS FINISH AND
PREPARE TO RECEIVE NEW
REINFORCED PARAMITER SECUREMNT DETAIL
1" POLYISO INSULATION
EXPOSED STRUCTURAL
STEEL, REFERENCE
STRUCTURAL DRAWINGS,
PAINT WITH INTUMESCENT
PAINT, PT-3
METAL PANEL SYSTEM ON
CARRIER
TPO ROOF MEMBRANE, EXTEND
ON TOP OF CHANNEL
PLYWOOD DECKING,
REFERENCE STRUCTURAL
DRAWINGS
STRUCTURAL WOOD AND
JOISTS, REFRENCE
STRUCTURAL DRAWINGS
BACKER ROD AND
CONTINUOUS SEALANT, PER
PANEL REQ.
TAPERED RIGID INSULATION
VARIESMEMB FLASH
COATED MET DRIP
EDGE. COLOR TO
MATCH PAINT PT-3
5A
A.401c
WATERPROOFING
MEMBRANE UNDER TOP
CAP
PRECAST CONCRETE
CAP, STAINED TO
MATCH DRY STONE
DRY STONE: 4" DRY
STACKED STONE
VENEER, PROVIA, DRY
STACK COLOR EIRIE
EMBED STEEL COLUMN
IN CONCRETE BASE
CONCEAL DRAIN
PIPE IN CONCRETE
BASE.
EXPANSION JOINT
WHERE PAVING
MEETS BASE
CAST IRON, SQUARE
DRAIN PIPE. FINISH
TO MATCH
ADJACENT STEEL
STRUCTURE
2"REFER TO STRUCTURAL DRAWINGS
1 3/4"2'-0 1/2"1 3/4"
2'-4"1'-10" 2'-0"REFER TO STRUCTURAL DRAWINGS COATED MET DRIP EDGE
MEMB FLASH
FASTNER 4" OC STAGGERED
CONT 2x6 PT WD NAILER SHIM AS REQ
MEMB. ROOFING - EXTEND
OVER EDGE OF BUILDING
RIGID INSULATION -1 1/2" MIN.
BACKER ROD AND CONTINUOUS
SEALANT, PER PANEL REQ.
METAL PANEL SYSTEM ON
CARRIER
STRUCTURE - REFER TO
STRUCTURAL DRAWINGS
METAL WRAP DARK
BRONZE FINISH
5/8" DENSGLASS
SHEATHING
DRIP EDGE
PT WD BLOCKING
CONTINUES CLEAT
3A
A.401c
2A
A.401c
LANDSCAPE FABRIC WITH
COARSE GRAVEL BELOW
PLANTING MIX
DRY STONE: 4" DRY
STACKED STONE VENEER,
PROVIA, DRY STACK
COLOR EIRIE
PRECAST CONCRETE
CAP, STAINED TO
MATCH DRY STONE
MORTAR BED, TYP. SLOPE TO DRAIN.
WEEP HOLES, 24" O.C.
WATERPROOF ALL INSIDE
FACE OF CONCRETE
CL
REFERENCE STRUCTURAL
DRAWINGS FOR CONCRETE
CONSTRUCTION DETAILS
REFERENCE
STRUCTURAL
DRAWINGS FOR REBAR
LOCATION AND
INFORMATION
WATERPROOFING
MEMBRANE UNDER TOP
CAP
PRECAST CONCRETE
CAP, STAINED TO MATCH
DRY STONE
DRY STONE: 4" DRY
STACKED STONE
VENEER, PROVIA, DRY
STACK COLOR EIRIE
EMBED STEEL COLUMN IN
CONCRETE BASE
CONCEAL DRAIN PIPE
IN CONCRETE BASE.
EXPANSION JOINT
WHERE PAVING MEETS
COLUMN BASE
CAST IRON, SQUARE
DRAIN PIPE. FINISH TO
MATCH ADJACENT
STEEL STRUCTURE
3'-1"REFER TO STRUCTURAL DRAWINGS LANDSCAPE FABRIC WITH
COARSE GRAVEL BELOW
PLANTING MIX
DRY STONE: 4" DRY STACKED
STONE VENEER, PROVIA, DRY
STACK COLOR EIRIE
PRECAST CONCRETE CAP,
STAINED TO MATCH DRY
STONE
CL
MORTAR BED, TYP. SLOPE TO
DRAIN.
WEEP HOLES, 24" O.C.
EXPANSION JOINT WHERE
PAVING MEETS BASE
WATERPROOF ALL INSIDE FACE
OF CONCRETE
CL
STRUCTURAL STEEL BEYOND
REFERENCE STRUCTURAL
DRAWINGS FOR CONCRETE
CONSTRUCTION DETAILS
REFERENCE
STRUCTURAL
DRAWINGS FOR
CONCRETE
CONSTRUCTION
DETAILS
REFERENCE
STRUCTURAL
DRAWINGS FOR REBAR
LOCATION AND
INFORMATION
2'-9"
8"
4 3/4" 3 1/4"
1 1/2"1 1/2"2'-6"
8"
3 1/4" 4 3/4"
LANDSCAPINGREFERENCE STRUCTURAL
DRAWINGS FOR
INFORMATION
EXPANSION JOINT
WHERE PAVING
MEETS COLUMN BASE
STEEL COLUMN - REFER TO
STRUCTURAL DRAWINGS
NEW FLUID-APPLIED
VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED
EXTERIOR INSULATION
AND FINISHING SYSTEM
5/8" DENSGLASS
SHEATHING
PT WOOD
1ST FLOOR
0' - 0"
1/4" GALV ST GUTTER
BRACKETS @ 3'-0" OC
(PAINT TO MATCH)
MIDPOINT BETWEEN
GUTTER STRAPS
1/8" GALV ST GUTTER
BRACKETS @ 3'-0" OC
(PAINT TO MATCH)
MIDPOINT BETWEEN
GUTTER STRAPS
4" x 4" PRE-FIN MET
GUTER
METAL WRAP DARK
BRONZE FINISH
5/8" DENSGLASS
SHEATHING
STEEL COLUMN - REFER TO
STRUCTURAL DRAWINGS
COATED MET DRIP EDGE
MEMB FLASH
FASTNER 4" OC STAGGERED
DRIP EDGE
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED
EXTERIOR INSULATION AND
FINISHING SYSTEM
5/8" DENSGLASS SHEATHING
CONT 2x6 PT WD NAILER SHIM
AS REQ
MEMB. ROOFING - EXTEND
OVER EDGE OF BUILDING
BACKER ROD AND CONTINUOUS
SEALANT, PER PANEL REQ.
METAL PANEL SYSTEM ON
CARRIER
RIGID INSULATION -1 1/2" MIN.
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 12:14:58 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
DETAILS - PORTE
COCHERE
05/14/2019 -
PERMIT SET
A.401c
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE: 1 1/2" = 1'-0"DRAWING REF: A.401b4CPORTECOCHERE-LOW ER
ROOF
SCALE: 1 1/2" = 1'-0"DRAWING REF: A.401b3CPORTECOCHERE-LOW ER
ROOF @ VESTIBULE
SCALE: 1 1/2" = 1'-0"DRAWING REF: A.401b2CDETAIL-S ECTION
-PORTE
COCHERE ROOF
SCALE: 1 1/2" = 1'-0"DRAWING REF: A.401a 3A DETAIL -SECTION
COLUMN
SCALE: 1 1/2" = 1'-0"DRAWING REF: A.401a5CPORTECOCHERE-LOW ER
ROOF
SCALE: 1 1/2" = 1'-0"DRAWING REF:A.401a5ADETAIL-SECTION
-COLUMN
AT PLANTER
SCALE: 1 1/2" = 1'-0"DRAWING REF: A.401a2ADETAIL-S ECTION
PLANTER
SCALE: 1 1/2" = 1'-0"DRAWING REF:A.401a6ADETAIL-SECTION
-LOW
ROOF COLUMN BASE
SCALE: 1 1/2" = 1'-0"DRAWING REF: A.401a6CPORTECOCHERE-LOW ER
ROOF @ COLUMN
KEYNOTES
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
J
J
J
J
1A
A.402b
6A
A.402b
3C
A.402b
3A
A.402b
5C
A.402b
4A
A.402b
A.402c
6A
A.402c
6A
A.402c
6C
1'-8 1/4"+/- 26'-11 1/2"1'-0 5/8" 7'-4" 1'-8" 7'-4" 1'-8" 7'-4" 6 7/8"1'-3 1/4"07.24.13.A
06.10.00.E
08.41.13.A
07.24.13.A
07.24.13.A
ST-01
08.41.13.A
ST-01
08.41.13.A
ST-01
TYP.
TYP.
A.402c
6B
A.402c
5B
32.92.00
03.30.00
07.24.13.A
03.30.00
07.24.13.A
03.30.00
08.41.13.A
ST-02
ST-02
1'-3 1/4" 1'-8"
1'-8"
32.92.00
07.24.13.A
TYP.
6A
A.401c
5C
A.402b
4A
A.402b ALL NEW ROOF SLOPES1/4":1'-0" MIN. TYPALL NEW ROOF SLOPES1/4":1'-0" MIN. TYP22.14.28.B
07.21.00.E
07.21.00.E
07.21.00.E
07.32.13.A
07.72.00.A
5C
A.401c
6C
A.401c
22.14.28.A
22.14.28.B
22.14.28.A
5C
A.402b
4A
A.402b
A.402c
6A
07.42.50
10.14.00
07.24.13.A
07.24.13.A
07.24.13.A
07.24.13.A
07.24.13.A
6C
A.401c
C EF-1
9' - 0" A.F.F.
C EF-1
9' - 0" A.F.F.
C 401
7' - 11 3/4" A.F.F.
C 401
7' - 11 3/4" A.F.F.
C 401
C 401
C 401
7' - 11 3/4" A.F.F.
C 401
7' - 11 3/4" A.F.F.
C 401
7' - 11 3/4" A.F.F.
C 401
7' - 11 3/4" A.F.F.
C 401
09.29.00.A
09.91.23.H
09.91.23.H
09.91.23.H
09.91.23.H
09.91.23.H
07.24.13.A
07.24.13.A
NOT ACCESSIBLE
SPACE
26.56.20
C EF-3
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 12:15:06 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
ENLARG ED PLANS -
MAIN ENTRANCE
05/14/2019 -
PERMIT SET
A.402a
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:1/4" = 1'-0"1 A ENLARGED PLAN -MAIN ENTRANCE
SCALE:1/4" = 1'-0"DRAWING REF:A.1146AENLARGEDROOFPLAN-MAIN ENTRANCE
SCALE:6E PERSPECTIVE
SCALE: 1/4" = 1'-0" DRAWING REF: A.1114A
ENLARGED PLAN
MAIN ENTRANCE UPPER LEVEL
SCALE: 1/4" = 1'-0" 2A
ENLARGED PLAN
MAIN ENTRANCE REFLECTED CEILING PLAN
SCALE: 1/4" = 1'-0"5A
ENLARGED PLAN
MAIN ENTRANCE UPPER LEVEL
REFLECTED CEILING PLAN
KEYNOTES
03.30.00 CAS T-IN-PLACE CONCRETE FLOOR SLAB. SEE S TRUCTURAL DRAWINGS.
06.10.00.E STRONG WALL REFER TO STRUCTURAL DRAWINGS FOR DETAILS
07.21.00.E BUILD UP CRICKET WITH RIGID INSULATION.
07.24.1 3.A EIFS COATINGS - REFER TO ELEVATIONS FOR COLOR
07.32.13.A REUSE CERAMIC TILE SAVED FROM DEMOLITION OR PROVIDE NEW TO
MATCH EXISTING
07.42.50 NICHINA FIBER CEMENT PANEL SYSTEM.
07.72.00.A PREMANUFACTURED COPING - METAL ERA PERMA TILE CONTINUES CLEAT
08.41.13.A
09.29.00.A PROVIDE NEW SOFFIT. MATCH ADJACENT SOFFIT ELEVATION AND TEXTURE.
09.91.23.H PREP AND PAINT SOFFIT
1 0.1 4.00 OFCI SIGNAGE. PROVIDE BLOCKING AND POWER TO SIGNAGE PER
ELECTRICAL DRAWINGS.
22.14.28.A PRIMARY ROOF DRAIN. CONCEAL PRIMARY ROOF DRAIN IN ROOF
ASSEMBLY. CONNECT TO UNDERGROUND STORM/SEVER RUNOFF SYSTEM.
WHEN POSSIBLE LOCATE TO EXISTING LOCATION FROM DEMOLISHED
DOWNSPOUT
22.14.28.B OVERFLOW ROOF DRAIN.
26.56.20 NEW EXTERIOR RECESSED LIGHT. REFERENCE ELECTRICAL DRAWINGS.
32.92.00 ADD LANDSCAPE
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
1st Floor
A.402c
3A3'-6"10'-0" 9'-0" 22'-6"3RD FLOOR
18' - 7"
2ND FLOOR
9' - 3"
1 ST FLOOR
0' - 0"
A.402c
5E SIM
+/- 14'-5 5/8"A.402c
4D SIM
1st Floor
3RD FLOOR
18' - 7"
2ND FLOOR
9' - 3"
1 ST FLOOR
0' - 0"
+/- 14'-5 5/8"3'-6"9'-9" 9'-3" 22'-6"A.402c
5E SIM
A.402c
4D SIM
1st Floor
EF-3
3RD FLOOR
18' - 7"
2ND FLOOR
9' - 3"
1 ST FLOOR
0' - 0"
A.402c
5E SIM
3'-6"10'-0" 9'-0" A.402c
4D SIM
1st Floor
3RD FLOOR
18' - 7"
2ND FLOOR
9' - 3"
1 ST FLOOR
0' - 0"
A.402c
5E SIM
3'-6"10'-0" 9'-0" +/- 14'-5 5/8"22'-6"A.402c
4D SIM
1ST FLOOR
0' - 0"
2ND FLOOR
9' - 3"
3RD FLOOR
18' - 7"
1A
A.402b
6A
A.402b
3C
A.402b
3A
A.402b
4A
A.402b
A.402c
6D
FC-1
A.402c
5E
A.402c
4D
3RD
18'
1 ST
0'
1st Floor
A.402c
3C
A.402c
4A
3RD FLOOR
18' - 7"
2ND FLOOR
9' - 3"
1ST FLOOR
0' - 0"3'-6"10'-0" 9'-0" +/- 14'-5 5/8"22'-6"E.Q. E.Q. E.Q. E.Q. E.Q. E.Q.E.Q.E.Q. E.Q. E.Q. 22'-6"07.42.50.A
07.24.13.B
EF-3
FC-1
EF-1
EF-1EF-1 EF-1
?
EF-1EF-1
EF-3EF-2
EF-2
ALIGN
EF-1
EF-1
EF-1
EF-1 EF-1
EF-3
EF-3
NO WORK IN THIS AREA
POCHE LEGEND
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 12:15:11 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
ENLARG ED SECTIONS -
MAIN ENTRANCE
05/14/2019 -
PERMIT SET
A.402b
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:1/4" = 1'-0"DRAWING REF:A.2011AMAINENTRANCE-SECTION
SCALE:1/4" = 1'-0"DRAWING REF:A.201 6A MAIN ENTRANCE -SECTION
SCALE:1/4" = 1'-0"DRAWING REF:A.2013CMAINENTRANCE-SECTION
SCALE:1/4" = 1'-0"DRAWING REF:A.201 3A MAIN ENTRANCE -SECTION
SCALE:1/4" = 1'-0"DRAWING REF:A.401a 5C MAIN ENTRANCE -SECTION
SCALE:1/4" = 1'-0"DRAWING REF:A.201 4A MAIN ENTRANCE -SECTION
KEYNOTES
07.24.13.B REVEAL IN EIFS COATINGS
07.42.50.A CONTROL JOINT
SCALE:1/4" = 1'-0"5D MAIN ENTRANCE -FRONT ELEVATION
SCALE:1/4" = 1'-0"3D MAIN ENTRANCE -SIDE ELEVATION
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
EXISTING EXTERIOR WALL. PREPARE
ETR EIFS AS REQUIRED TO RECEIVE
NEW PAINT
EXISTING EXTERIOR WALL FRAMING
AND INSULATION. REMOVE EIFS AND
SHEETING TO THE EXTEND SHOWN
1" POLYMER-BASED EXTERIOR
INSULATION AND FINISHING
SYSTEM
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
FOR SHEATHING, FRAMING &
FOUNDATION REFER TO
STRUCTURAL DRAWINGS
CONCEAL STORM PIPE
WITHIN NEW STRUCTURE
EXISTING EXTERIOR WALL.
PREPARE ETR EIFS AS
REQUIRED TO RECEIVE
NEW PAINT
BACKER ROD AND
CONTINUES SEALANT
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED
EXTERIOR INSULATION AND
FINISHING SYSTEM
5/8" DENSGLASS SHEATHING
1/2" RESILIANT CHANNEL
SOFFIT VENT
SOFFIT DRIP EDGE
2X WD FRAMING REFER TO
STRUCTURAL DRAWINGS
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED
EXTERIOR INSULATION AND
FINISHING SYSTEM
5/8" DENSGLASS SHEATHING
UNFACED BATT
INSULATION
PREMANUFACTURED
COPING - METAL ERA PERMA
TITE CONTINUOUS CLEAT
COPING
BUTYL SEALING TAPE
FULLY ADHERED, CONTINUOUS
TPO ROOF MEMBRANE,
EXTEND OVER PARAPET AND
SECURE TO OUTSIDE FACE OF
SHEATHING
TAPERED RIGID INSULATION
3/4" PLYWOOD
PLYWOOD SHEATHING
TURN FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER ON
TOP OF WALL ADHERE ROOF
MEMBRANE TO IT
NEW 2X WD FRAMING,
REFERENCE STRUCTURAL
DRAWINGS
NEW CEMENT PANELS ON
PROPRIETARY CLIP SYSTEM
EXTERIOR RECESSED LIGHT
FIXTURE, REFERENCE
ELECTRICAL DRAWINGS FOR
MORE INFORMATION
CL
FULLY ADHERED, CONTINUOUS
TPO ROOF MEMBRANE,
EXTEND OVER PARAPET AND
SECURE TO OUTSIDE FACE OF
SHEATHING
TAPERED RIGID INSULATION
3/4" PLYWOOD
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED
EXTERIOR INSULATION AND
FINISHING SYSTEM
5/8" DENSGLASS SHEATHING
1/2" RESILIANT CHANNEL
UNFACED BATT INSULATION
1" POLYMER-BASED EXTERIOR
INSULATION. INSULATION COMPRESIVE
STRENGHT OF 25 PSI MIN.
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
NEW SHEATHING
NEW OR EXISTING 2X WD
FRAMING, REFERENCE
STRUCTURAL DRAWINGS
EXISTING TO REMAIN OR
PROVIDE NEW UNFACED
BATT INSULATION. GC TO VIF.
5 1/2"BACKER ROD AND
CONTINUES SEALANT
TURN FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER ON
TOP OF WALL ADHERE ROOF
MEMBRANE TO IT
TAPERED CRICKET
PREMANUFACTURED COPING - METAL ERA
PERMA TITE CONTINUOUS CLEAT COPING
REF ROOF PLAN
FOR CRICKET SIZE
EXTENT OF ROOFING MEMBRANE
PRE-FINISHED THRU WALL
FLASHING
REMOVABLE COUNTERFLASHING
BUTYL SEALING TAPE
REUSE ROOF TILE SAVED FROM
DEMOLITION OR PROVIDE NEW
TO MATCH EXISTING
5/8" DENSGLASS SHEATHING
3/4" PLYWOOD
UNFACED BATT
INSULATION
WD FRAMING - REFER TO
STRUCTURAL DRAWINGS
EXTEND TPO ROOF
MEMBRANNE AND
SECURE AT LEAST 2'-0"
MIN UNDER ROOF TILE
EXISTING TO REMAIN
ROOF STRUCTURE
EXISTING SOFFIT TO REMAIN
PREP AND PAINT AS REQIRED
ALIGN
ALIGN
PROVIDE NEW SOFIT
UNFACED BATT INSULATION
1/2" GWB
1'-0" CLEAR MIN 2'-0" MIN.
MEMBRANE FALSHING - ADHERE
TO WALL
TPO ROOF MEMBRANNE
PROVIDE BLOCKING AS REQUIRED
BASE SECURMENT, NOT SHOWN
SILL OPEN END
OF END TILE OR
PROVIDE BUG
SCREEN
NEW CEMENT PANELS
ON PROPRIETARY CLIP
SYSTEM
1" POLYMER-BASED EXTERIOR
INSULATION. INSULATION
COMPRESIVE STRENGTH OF 25 PSI
MIN.
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
NEW SHEATHING
NEW OR EXISTING 2X WD
FRAMING, REFERENCE
STRUCTURAL DRAWINGS
EXISTING TO REMAIN OR
PROVIDE NEW UNFACED
BATT INSULATION. GC TO VIF.
NEW BEAM. REFER TO
STRUCTURAL DRAWINGS FOR
DETAILS
METAL FLASHING
PROVIDE BUG SCREEN AT
EXPOSED ENDS OF FIBER
CEMENT PANEL WALLS
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED EXTERIOR
INSULATION AND FINISHING SYSTEM
5/8" DENSGLASS SHEATHING
SOFFIT VENT
SOFFIT DRIP EDGE
UNFACED BATT INSULATION
1/2" RESILIANT CHANNEL
EXISTING STRUCTURE TO
REMAIN
EXISTING EXTERIOR
WALL.REPAIR AND
PREPARE ETR EIFS AS
REQUIRED TO RECEIVE
NEW PAINT
BACKER ROD AND
CONTINUES SEALANT
COLUMN BEYOND
2x WD FRAMING REFER TO
STRUCTURAL DRAWINGS
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED EXTERIOR
INSULATION AND FINISHING
SYSTEM
5/8" DENSGLASS SHEATHING
1/2" RESILIANT CHANNEL
FULLY ADHERED, CONTINUOUS
TPO ROOF MEMBRANE, EXTEND
OVER PARAPET AND SECURE TO
OUTSIDE FACE OF SHEATHING
TAPERED RIGID INSULATION
3/4" PLYWOOD
ROOF DRAIN - REFER TO
PLUMBING DRAWINGS FOR
DETAILS
TURN FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER ON TOP OF
WALL ADHERE ROOF MEMBRANE TO IT
STRONG WALL REFER
TO STRUCTURAL
1" POLYMER-
BASED EXTERIOR
INSULATION AND
FINISHING SYSTEM
NEW FLUID-APPLIED
VAPOR
PERMEABLE AIR BARRIER
NEW SHEATHING
FRAMING REFER TO
STRUCTURAL
2x WOOD FRAMING
REINSTALL
STOREFRONT
SAVED FROM
DEMOLITION OR
PROVIDE NEW TO
MATCH EXISTING
PROVIDE NEW
STOREFRONT
EDGE OF NEW
CONCRETE SLAB
PROVIDE NEW
CERAMIC FLOOR
TILE
PROVIDE NEW GWB AND
REPAIR EXISTING FINISH TO
MATCH EXISTING WALL
FINISH
PROVIDE NEW GWB AND REPAIR
EXISTING FINISH TO MATCH
EXISTING WALL FINISH
EXISTING DOOR TO REMAIN
REINSTALL CARD READER
SAVED FROM DEMOLITION
FRAME NEW WALL
CL
WATERBLOCK SEAL
PROTECTION
BOARD
MEMBRANE ROOFING -
EXTEND 3/4" INTO BOWL
DOME STRAINER WITH
GRAVEL STOP RING
CLAMPING RING
CONNECT TO PIPE
2"6"4". 1" EIFS
SUBSTRATE
2x6 ROOF JOIST @ 16"
O.C
2x6 WOOD STUD WALL
1" EIFS
16"X 6" PREFINISHED
ALUMINUM SCUPPER PAN,
WATERTIGHT
CONT SEALANT
TAPERED RIGID
INSULATION
SINGLE PLY MEMBRANE
CONT UNDER SCUPPER,
ATTACH TO EIFS
MEMBRANE FLASHING
CONT
SEALANT
CONT SEALANT
SINGLE PLY MEMBRANE
TO COUNTER FLASH
WOOD BLOCKING
2x6 WOOD STUD WALL
SUBSTRATE
SUBSTRATE
CONT SEALANT
2" DRIP EDGE LIP
CONT CLEAT
NOTE:
SET BOTTOM OF 16"X 6" OVERFLOW
SCUPPERS AT 3" ABOVE BOTTOM OF
NEAREST DS COLLECTOR.
CONT SEALANT
WOOD BLOCKING
TAPERED RIGID
INSULATION
1'-6" 1 5/8"1'-6" 1 5/8"1 5/8" 1'-9 1/4"1 5/8"
1'-9 1/4"
STRONG WALL REFER
TO STRUCTURAL
1" POLYMER-
BASED EXTERIOR
INSULATION AND
FINISHING SYSTEM
ALL 4 SIDES
NEW FLUID-APPLIED
VAPOR
PERMEABLE AIR BARRIER
ALL 4 SIDES
NEW SHEATHING
ALL 4 SIDES
FRAMING REFER TO
STRUCTURAL
2x WOOD FRAMING
EXISTING STOREFRONT TO REMAIN
1" POLYMER-BASED EXTERIOR
INSULATION AND FINISHING SYSTEM
EXISTING EXTERIOR WALL. PREPARE
ETR EIFS AS REQUIRED TO RECEIVE
NEW PAINT
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
FOR SHEATHING, FRAMING &
FOUNDATION REFER TO
STRUCTURAL DRAWINGS
EDGE OF NEW CONCRETE
SLAB BELOW. REFER TO
STRUCTURAL DRAWINGS
UNFACED BATT INSULATION
5/8" GWB. PROVIDE NEW
AND REPAIR EXISTING
WALLS AS REQUIRED.
BACKER ROD AND CONTINUES SEALANT
PROVIDE NEW
STOREFRONT. FINISH TO
MATCH EXISTING
ADJACENT STOREFRONT.
A.002
2B
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 12:15:17 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
DETAILS - MAIN
ENTRANCE
05/14/2019 -
PERMIT SET
A.402c
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE: 1 1/2" =1'-0"DRAWING REF:A.402a6AMAINENTRYBUILDOUT -PLAN DETAIL
SCALE: 1 1/2" =1'-0"DRAWING REF:A.401b5EMAINENTRYBUILDOUT- DETAIL
SCALE: 1 1/2" =1'-0"DRAWING REF:A.402b4DMAINENTRYBUILDOUT-DETAIL
SCALE: 1 1/2" =1'-0"DRAWING REF:A.401b3CMAINENTRYBUILDOUT-DETAIL
SCALE: 1 1/2" =1'-0"DRAWING REF:A.402b3AMAINENTRYBUILDOUT-DETAIL
SCALE: 1 1/2" =1'-0"DRAWING REF:A.402b6DMAINENTRYBUILDOUT-DETAIL
SCALE: 1 1/2" =1'-0"DRAWING REF:A.402a6CMAINENTRYBUILDOUT- PLAN DETAIL
SCALE: 1 1/2" =1'-0"4C TYPICAL DETAIL - ROOF DRAIN
SCALE: 1 1/2" =1'-0"4B TYPICAL DETAIL - OVERFLOW SCUPPER
SCALE: 1 1/2" =1'-0"DRAWING REF:A.402a6BMAINENTRYBUILDOUT- PLAN DETAIL
SCALE: 1 1/2" =1'-0"DRAWING REF:A.402a5BMAINENTRYBUILDOUT- PLAN DETAIL
SCALE: 1 1/2" =1'-0"DRAWING REF:A.402b4AMAINENTRYBUILDOUT- DETAIL
KEYNOTES
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
A.403b
1A
2A
A.403c
4A
A.403c
A.403d
1A
A.403d
2A
A.403d
2B
8'-3 1/2" 7'-11 1/2"
07.24.13.A
4C
A.403c
A.403b
5C
A.403b 3C
2C
A.403c
A.403d
2B
A.403d
2A
A.403d
1A
07.42.50
07.24.13.A07.24.13.A
A.403b 3A
A.403b
1A
2A
A.403c A.403b
5A
4A
A.403c
SLOPE1/4":1'-0" MIN22.14.28.B
22.14.28.A
07.72.00.C
A.403b
5C
A.403b 3C
SLOPE1/4":1'-0" MINEXISTINGSLOPE22.14.28.B
22.14.28.A
4C
A.403c
2C
A.403c
1A
A.403d
07.42.50
07.24.13.A
2A
A.403c
4A
A.403c
A.403d
3A
07.42.50 07.24.13.A
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 12:15:28 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
ENLARG ED PLANS,
REFLECTED CEILING
PLANS & DETAILS -
FRONT STAIRCASE #1 &
#2
05/14/2019 -
PERMIT SET
A.403a
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:1/4" = 1'-0"DRAWING REF: A.1111AENLARGEDFIRSTFLOOR PLAN - STAIRCASE #1
SCALE:1/4" = 1'-0"DRAWING REF: A.1111CENLARGEDFIRSTFLOOR PLAN - STAIRCASE #2
SCALE:6E PERSPECTIVE - STAIRCASE #1
KEYNOTES
07.24.1 3.A EIFS COATINGS - REFER TO ELEVATIONS FOR COLOR
07.42.50 NICHINA FIBER CEMENT PANEL SYSTEM.
07.72.00.C MODIFY EXCISING VENT AND FLASH AS REQUIRED FOR NEW ROOF.
ELEVATION.
22.14.28.A PRIMARY ROOF DRAIN. CONCEAL PRIMARY ROOF DRAIN IN ROOF
ASSEMBLY. CONNECT TO UNDERGROUND STORM/SEVER RUNOFF SYSTEM.
WHEN POSSIBLE LOCATE TO EXISTING LOCATION FROM DEMOLISHED
DOWNSPOUT
22.14.28.B OVERFLOW ROOF DRAIN.
SCALE:1/4" = 1'-0"DRAWING REF:A.1145AENLARGEDROOFPLAN- STAIRCASE #1
SCALE:1/4" = 1'-0"DRAWING REF:A.1145CENLARGEDROOFPLAN- STAIRCASE #2
SCALE:4E PERSPECTIVE - STAIRCASE #2
SCALE:1/4" = 1'-0"3C ENLARGED SECOND FLOOR PLAN - STAIRCASE #2
SCALE:1/4" = 1'-0"3A ENLARGED SECOND FLOOR PLAN - STAIRCASE #1
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
2A
A.403c
4A
A.403c
?
FC-1
EF-3
E.Q. E.Q. E.Q. E.Q.
EF-3
EF-3FC-1
4C
A.403c
2C
A.403c
EF-3
2A
A.403c
4A
A.403c
EF-3
4C
A.403c
2C
A.403c
FC-1 EF-3
EF-3
EF-2
EF-3
FC-1
EF-3
EF-3 EF-3
E.Q. E.Q. E.Q.3'-4"+/- 30'-10" +/- 35'-2"26'-3 1/2"
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 12:15:29 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
ENLARG ED ELEVATIO NS
- FRONT S TAIRCAS E #1
& #2
05/14/2019 -
PERMIT SET
A.403b
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:1/4" = 1'-0"DRAWING REF: A4011ASTAIRCASE #1 - PARKING ELEVATION
SCALE:1/4" = 1'-0"DRAWING REF:A.403a3ASTAIRCASE #1 -FRONT
ELEVATION
SCALE:1/4" = 1'-0"DRAWING REF: xG0021CSTARICASE #2 - COURTYARD ELEVATION
SCALE:1/4" = 1'-0"DRAWING REF: A.403a5ASTAIRCASE #1 - COURTYARD ELEVATION
SCALE:1/4" = 1'-0"DRAWING REF:A.403a5CSTAIRCASE #2 - PARKING ELEVATION
SCALE:1/4" = 1'-0"DRAWING REF:A.1103CSTARICASE #2 -FRONT
ELEVATION
KEYNOTES
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
T.O. PLATTE
HIGH EAVE
LOW EAVE
1 st Floor
A.403d
4C SIM
A.403d
2C SIM
High Eave
30' - 9 3/4"
Low Eave
28' - 3 3/4"
T.O. Platte
26' - 9 3/4"
3RD FLOOR
18' - 7"
2ND FLOOR
9' - 3"
1 ST FLOOR
0' - 0"
A.402c
3C SIM
T.O. PLATTE
HIGH EAVE
LOW EAVE
1st Floor
High Eave
30' - 9 3/4"
Low Eave
28' - 3 3/4"
T.O. Platte
26' - 9 3/4"
3RD FLOOR
18' - 7"
2ND FLOOR
9' - 3"
1 ST FLOOR
0' - 0"
A.403d
4C SIM
T.O. PLATTE
HIGH EAVE
LOW EAVE
1st Floor
A.403d
4B
A.403d
4C
A.403d
2C
Level 1
Level 2
10' - 0"
High Eave
30' - 9 3/4"
Low Eave
28' - 3 3/4"
T.O. Platte
26' - 9 3/4"
3RD FLOOR
18' - 7"
2ND FLOOR
9' - 3"
1 ST FLOOR
0' - 0"
A.402c
3C SIM
T.O. PLATTE
HIG H EAVE
LOW EAVE
1 st Floor
Level 1
Level 2
10' - 0"
High Eave
30' - 9 3/4"
Low Eave
28' - 3 3/4"
T.O. Platte
26' - 9 3/4"
3RD FLOOR
18' - 7"
2ND FLOOR
9' - 3"
1 ST FLOOR
0' - 0"
A.403d
4C SIM
07.24.13.A
07.24.13.A
07.24.13.A
07.42.50
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 12:15:31 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
ENLARGED SECTIONS &
DETAILS - FRONT
S TARICAS E #1 & #2
05/14/2019 -
PERMIT SET
A.403c
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:1/4" = 1'-0"DRAWING REF: A.2014CSTAIRCASE #2 -SECTION
SCALE: 1/4" = 1'-0" DRAWING REF: A.2022CSTAIRCASE#2 -SECTION
SCALE: 1/4" = 1'-0" DRAWING REF: A.403a2ASTAIRCASE #1 -SECTION
SCALE:1/4" = 1'-0" DRAWING REF: A.403a 4A STAIRCASE #1 -SECTION
KEYNOTES
07.24.1 3.A EIFS COATINGS - REFER TO ELEVATIONS FOR COLOR
07.42.50 NICHINA FIBER CEMENT PANEL SYSTEM.
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
BACKER ROD AND
CONTINUOUS SEALANT,
PER PANEL REQ.
FIBER CEMENT PANELS
ON PROPRIETARY CLIP
SYSTEM
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED
EXTERIOR INSULATION.
INSULATION COMPRESSIVE
STRENGTH OF 25 PSI
NEW SHEATHING
EXISTING WALL
TO REMAIN.
REMOVE
SHEATHING AND
EIFS FINISH AND
PREPARE TO
RECEIVE NEW.
FRAMING MAY
VARIES. GC TO
VIF
WRAP IN METAL -FINISH
TO MATCH FIBER CEMENT
PANELS
NEW SHEATHING
TIE STEEL ANGLE TO
EXISTING FRAMING.
GC TO VIF
FACE OF FIBER
CEMENT PANEL ABOVE
1" POLYMER-
BASED EXTERIOR
INSULATION AND
FINISHING
SYSTEM
NEW FLUID-APPLIED
VAPOR
PERMEABLE AIR
BARRIER
CAULK
1/2" MIN. - 1" MAX.
1" POLYMER-BASED
EXTERIOR INSULATION AND
FINISHING SYSTEM
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
FOR SHEATHING, FRAMING &
FOUNDATION REFER TO
STRUCTURAL DRAWINGS
CONCEAL STORM PIPE
WITHIN NEW STRUCTURE
EXISTING EXTERIOR
WALL FRAMING AND
INSULATION. REMOVE
EIFS AND SHEETING TO
THE EXTEND SHOWN
EXISTING TO REMAIN WALL
SHEATHING AND EIFS. FRAMING
MAY VARIES. GC TO VIF
1" POLYMER-BASED
EXTERIOR
INSULATION AND
FINISHING SYSTEM
NEW FLUID-APPLIED
VAPOR
PERMEABLE AIR
BARRIER
FOR SHEATHING, FRAMING &
FOUNDATION REFER TO
STRUCTURAL DRAWINGS
NEW SHEATHING
2'-6".1'-0".
EXISTING WALL
TO REMAIN.
REMOVE
SHEATHING AND
EIFS FINISH AND
PREPARE TO
RECEIVE NEW.
FRAMING MAY
VARIES. GC TO
VIF
EXISTING STORE
FRONT TO
REMAIN
EXISTING STEEL
DOOR AND FRAME
TO REMAIN
FIBER CEMENT PANELS ON
PROPRIETARY CLIP SYSTEM
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
OVER:
OVER:
1" POLYMER-BASED
EXTERIOR INSULATION.
INSULATION COMPRESSIVE
STRENGTH OF 25 PSI
OVER:
NEW SHEATHING
TRIM WITH METAL ON
EXPOSED ENDS
BACKER ROD AND
CONTINUOUS SEALANT,
PER PANEL REQ.
PREFABRICATED OVERHANG
FLASHING BY FIBER CEMENT
PANELS MANUFACTURER
EXISTING EFIS TO REMAIN.
PREP AS REQUIRED TO
RECEIVE NEW PAINT FINISH
FIBER CEMENT PANELS ON
PROPRIETARY CLIP SYSTEM
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED EXTERIOR
INSULATION. INSULATION
COMPRESSIVE STRENGTH OF 25 PSI
NEW SHEATHING
EXISTING WD STRUCTURE TO
REMAIN. REMOVE SHEATHING AND
EXTERIOR WALL FINISH
REPAIR AS REQUIRED WITH POLYMER-
BASED EXTERIOR INSULATION AND
FINISHING SYSTEM. MATCH ADJACENT
EXISTING ADJACENT EFIS THICKENS
AND FINISH
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED
EXTERIOR INSULATION AND
FINISHING SYSTEM
5/8" DENSGLASS SHEATHING
1/2" RESILIANT CHANNEL
SOFFIT VENT
SOFFIT DRIP EDGE
NEW FRAMING REFER TO
STRUCTURAL DRAWINGS
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED
EXTERIOR INSULATION AND
FINISHING SYSTEM
5/8" DENSGLASS SHEATHING
UNFACED BATT
INSULATION
PREMANUFACTURED
COPING -METAL ERA PERMA
TITE CONTINUOUS CLEAT
COPING
BUTYL SEALING TAPE
FULLY ADHERED, CONTINUOUS
TPO ROOF MEMBRANE,
EXTEND OVER PARAPET AND
SECURE TO OUTSIDE FACE OF
SHEATHING
TAPERED RIGID INSULATION
PLYWOOD
ROOF FRAMING,
REFERENCE
STRUCTURAL
DRAWINGS
UNFACED BATT INSULATION
5 1/2"
CL
FIBER CEMENT PANELS ON
PROPRIETARY CLIP SYSTEM
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED EXTERIOR
INSULATION. INSULATION
COMPRESSIVE STRENGTH OF 25 PSI
NEW SHEATHING
EXISTING WD
STRUCTURE TO
REMAIN. REMOVE
SHEATHING AND
EXTERIOR WALL
FINISH
BACKER ROD AND CONTINUES
SEALANT
EXTERIOR RECESSED LIGHT FIXTURE,
REFERENCE ELECTRICAL DRAWINGS
FOR MORE INFORMATION
FRAME NEW
WALL OVER
EXISTING WALL.
REFER TO
STRUCTURAL
DRAWINGS FOR
DETAILS
TURN FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER ON
TOP OF WALL ADHERE ROOF
MEMBRANE TO IT
MAINTAIN
EXISTING FIRE
RATING DURING
CONSTRUCTION
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED
EXTERIOR INSULATION AND
FINISHING SYSTEM
NEWSHEATHING
UNFACED BATT
INSULATION
PREMANUFACTURED
COPING -METAL ERA PERMA
TITE CONTINUOUS CLEAT
COPING
BUTYL SEALING TAPEFULLY ADHERED,
CONTINUOUS TPO ROOF
MEMBRANE, EXTEND
OVER PARAPET AND
SECURE TO OUTSIDE
FACE OF SHEATHING
TAPERED RIGID
INSULATION
3/4" PLYWOOD
TURN FLUID-APPLIED
VAPOR
PERMEABLE AIR BARRIER
ON TOP OF WALL ADHERE
ROOF MEMBRANE TO IT
1/2" MIN. - 1" MAX.NEW SHEATHING
EXISTING WALL TO REMAIN.
REMOVE SHEATHING AND EIFS
FINISH AND PREPARE TO
RECEIVE NEW. FRAMING MAY
VARIES. GC TO VIF
WRAP IN METAL -FINISH
TO MATCH FIBER CEMENT
PANELS
1" POLYMER-BASED
EXTERIOR INSULATION
AND FINISHING SYSTEM
NEW FLUID-APPLIED
VAPOR
PERMEABLE AIR BARRIER
CAULK
NEW FLUID-APPLIED
VAPOR PERMEABLE
AIR BARRIER
1" POLYMER-BASED
EXTERIOR
INSULATION.
INSULATION
COMPRESSIVE
STRENGTH OF 25 PSI
NEW SHEATHING
BACKER ROD AND
CONTINUOUS SEALANT,
PER PANEL REQ.
FIBER CEMENT PANELS
ON PROPRIETARY CLIP
SYSTEM
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2345 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 12:15:32 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
DETAILS - FRONT
S TIARCASE
05/14/2019 -
PERMIT SET
A.403d
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
KEYNOTES
SCALE: 1 1/2" = 1'-0"DRAWING REF: A.403a2AENLARGED PLAN DETAIL
SCALE: 1 1/2" = 1'-0"DRAWING REF:A.403a1AENLARGEDDETAIL-FOCAL
WALL
SCALE: 1 1/2" = 1'-0"DRAWING REF: A.403a2BENLARGED PLAN DETAIL
SCALE: 1 1/2" = 1'-0"DRAWING REF:A.403c 4B ENLARGED SECTION DETAIL
SCALE: 1 1/2" = 1'-0"DRAWING REF:A.403c 4C ENLARGED SECTION DETAIL
SCALE: 1 1/2" = 1'-0"DRAWING REF:A.403c2CENLARGEDSECTIONDETAIL
SCALE: 1 1/2" = 1'-0"DRAWING REF: A.403a3AENLARGED PLAN DETAIL
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
-A.404a 3C
-A.404a
2C
-A.404a1C
4C
-A.404a
A.403d
2A
A.403d
2B
23.07.19.A
4C
-A.404a
07.24.13.B07.24.13.B
07.42.50.B
+/- 1'-0"+/- 18'-5 1/4" +/- 1'-0" +/- 9'-0 1/4" +/- 29' -5 1/2"T.O. PLATTE
HIG H EAVE
LOW EAVE
1st Floor
-A.404a
6D
-A.404a
6C
-A.404a
6A
-A.404a
6D SIM
High Eave
30' - 9 3/4"
Low Eave
28' - 3 3/4"
T.O. Platte
26' - 9 3/4"
3RD FLOOR
18' - 7"
2ND FLOOR
9' - 3"
1 ST FLOOR
0' - 0"
4C
-A.404a
EXISTING SITE CONDITION. VERIFY IN
FIELD. B.O. FIBER CEMENT PANEL TO
BE HELD 2" MIN ABOVE BOTH SOIL
AND HARDSCAPING.
NEW METAL FLASHING
FIBER CEMENT PANELS ON
PROPRIETARY CLIP SYSTEM
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED EXTERIOR
INSULATION. INSULATION
COMPRESSIVE STRENGTH OF 25 PSI
MIN2"PROVIDE BUG SCREEN AT EXPOSED
ENDS OF FIBER CEMENT PANEL
WALLS
NEW SHEATHING
EXISTING WD STUD WALL TO REMAIN.
REMOVE SHEATHING AND EXTERIOR
WALL FINISH
EXISTING TO REMAIN ROOF STRUCTURE
EXISTING TO REMAIN ROOF TILE
FIBER CEMENT PANEL ON PROPRIETARY CLIP
SYSTEM
1" POLYMER-BASED EXTERIOR INSULATION.
INSULATION COMPRESSIVE STRENGTHS OF 25
PSI MIN.
NEW FLUID-APPLIED VAPOR PERMEABLE AIR
BARRIER
5/8" DENSGLASS SHEATHING
PROVIDE NEW GALV. COUNTERFLASHING
POP RIVETS AT 12" OC.
EXISTING WALL TO REMAIN. REMOVE
SHEATHING AND EIFS FINISH AND PREPARE
TO RECEIVE NEW
EXISTING WALL AND SHEATING TO REMAIN. GC TO
VERFY EXISTING BLOCKING LOCATION
OVRLAP EXISTING ROOF FELT UNDER NEW VAPER
BARRIER
PROVIDE BUG SCREEN AT EXPOSED ENDS OF
FIBER CEMENT PANEL WALLS
6" MIN.SOFT COPPER SHAPED TO CONFORM TILE
PROFILE
FIBER CEMENT PANELS ON
PROPRIETARY CLIP SYSTEM
NEW FLUID-APPLIED VAPOR
PERMEABLE AIR BARRIER
1" POLYMER-BASED EXTERIOR
INSULATION. INSULATION
COMPRESSIVE STRENGTH OF 25 PSI
NEW SHEATHING
EXISTING WD STUD WALL TO REMAIN.
REMOVE SHEATHING AND EXTERIOR
WALL FINISH
EXISTING TO REMAIN ROOF TRUSS
BACKER ROD AND CONTINUES
SEALANT
EXISTING TO REMAIN FACIA. PREP
AND REPAIR AS REQUIRED FOR
NEW PAINT FINISH
EXISTING TO REMAIN GUTTER.
PREP AND REPAIR AS REQUIRED
FOR NEW PAINT FINISH
EXISTING TO REMAIN ROOF TILE
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 11/21/2019 4:38:08 PM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
ENLARG ED PLANS,
REFLECTED CEILING
PLANS & DETAILS - SIDE
ENTRANCE
05/14/2019 -
PERMIT SET
A.404a
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
KEYNOTES
07.2 4.1 3.B REVEAL IN EIFS COATINGS
07.42.50.B CORNER TRIM
23.07.1 9.A EXISTING TO REMAIN HVAC UNIT. KEEP AND PROTECT DURING
CONSTRUCTION. MODIFY ELECTRICAL CONNECTIONS AND LINES AS
REQUIRED FOR NEW CONSTRUCTION
SCALE:1/4" = 1'-0"DRAWING REF:-A.404a 3C ELEVATION -SIDE ENTRANCE
SCALE:1/4" = 1'-0"1 A ENLARGED FIRST FLOOR PLAN -SIDE ENTRANCE
SCALE:6E PERSPECTIVE
SCALE:1/4" = 1'-0"DRAWING REF:-A.404a 2 C ELEVATION -SIDE ENTRANCE
SCALE:1/4" = 1'-0"DRAWING REF:-A.404a1CELEVATION-SIDE ENTRANCE
SCALE:1/4" =1'-0"DRAWING REF: -A.404a 4C SECTION -SIDE
ENTRANCE
SCALE:1/4" = 1'-0"3A ENLARGED SECOND FLOOR PLAN -SIDE ENTRANCE
SCALE: 1 1/2"= 1'-0"DRAWING REF: -A.404a 6A DETAIL -SIDE ENTRANCE
SCALE: 1 1/2"= 1'-0"DRAWING REF: -A.404a6CDETAIL-SIDE ENTRANCE
SCALE: 1 1/2"= 1'-0"DRAWING REF: -A.404a6DDETAIL-SIDE ENTRANCE
C 1 1 /20/2 01 9 BUILDING PERMIT REVIEW -
REVISION #3
C
1 1 /22/201 9
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
5A
A.405
A.4052B
A.405
3B
A.405
3C
A.405
4B
1/2" GWB ON FURRING STRIPS
CONTINUOUS TPO ROOF MEMBRANE
EXISTING
STRUCTURE
TO REMAIN
STRUCTURE
PLYWOOD AND CANOPY STRUCTURE -
REFER TO STRUCTURAL DRAWINGS
6B
A.405
MEMBRANE FLASHING - ADHERE TO WALL
PROVIDE BLOCKING AS REQUIRED
PRE-FIN MET GUTTER. MATCH
STYLE OF EXISTING GUTTERS.
PAINT TO MATCH BRONZE FINISH
METAL WRAP DARK
BRONZE FINISH
COATED MET DRIP EDGE
MEMB FLASH
FASTNER 4" OC STAGGERED
PROVIDE BLOCKING AS REQ
CAULK
HEAT WELDED SEAM (TYP)
CAULK
LIGHT FIXTURE - REFER TO
ELECTRICAL DRAWINGS
EXISTING WALL, SHEATHING AND EIFS
FINISH TO REMAIN. PREPARE TO
RECEIVE NEW PAINT FINISH.
EXISTING WALL, SHEATHING AND
EIFS FINISH TO REMAIN.
PREPARE TO RECEIVE NEW
PAINT FINISH.
PROVIDENEW EFIS AND SHEETING
AS REQUIRED
PROVIDENEW EFIS AND
SHEETING AS REQUIRED
A
5A
A.405
A.405
6B
EF-2EF-1 EF-4
6B
A.405
6A
A.405
3' - 6".19'-0 3/4"10" 8'-5" +/- 28'-3 3/4"EF-4
EF-4
A
6B
A.405
6A
A.405
1/2" GWB ON FURRING
STRIPS
METAL WRAP DARK
BRONZE FINISH
COATED MET
DRIP EDGE
MEMB FLASH
FASTNER 4" OC
STAGGERED
CAULK
EIFS (EF-4)
EIFS (EF-4)
EIFS - (EF-2)
EIFS (EF-2)
FRAMING - REFER TO
STRUCTURAL
1/4" GALV ST GUTTER BRACKETS
@ 3'-0" OC (PAINT TO MATCH)
MIDPOINT BETWEEN GUTTER
STRAPS
1/8" GALV ST GUTTER BRACKETS @
3'-0" OC (PAINT TO MATCH) MIDPOINT
BETWEEN GUTTER STRAPS
4" x 4" PRE-FIN MET GUTTER
EDGE OF CANOPY ABOVE
EXISTING WALL, SHEATHING AND EIFS
FINISH TO REMAIN. PREPARE TO
RECEIVE NEW PAINT FINISH.
PROVIDE EIFS
REPAIR AS REQUIRED WITH POLYMER-
BASED EXTERIOR INSULATION AND
FINISHING SYSTEM. MATCH ADJACENT
EXISTING ADJACENT EFIS THICKNES
AND FINISH
1/2" 3 1/2"1"
GALVANAIZE FLASHING - COLOR
MATCH FIBER CEMENT PANELS
PROVIDE BLOCKING AS REQUIRED
CAULK
STRUCTURAL MEMBER - REFER
TO STRUCTURAL DRAWINGS.
BUILD OUT AROUND NEW
STRUCTURE
+/- 10"WRAP IN METAL. DARK BRONZE
FINISH
EXISTING WALL, SHEATHING AND EIFS
FINISH TO REMAIN. PREPARE TO
RECEIVE NEW PAINT FINISH.
EXISTING WALL, SHEATHING AND EIFS
FINISH TO REMAIN. PREPARE TO
RECEIVE NEW PAINT FINISH.
A
5A
A.405
A.405 2B
A.405
3B
A.405
3C
6B
A.405 19'-2 1/16"12'-11 1/2" 1 1/2"6'-6 3/4"5 1/2" 3'-8" 4'-10" 3'-8" 5 1/2"1'-4 1/2"
NOT FOR
CONSTRUCTION
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 7/2/2019 5:54:06 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
ENLARG ED PLANS,
REFLECTED CEILING
PLANS & DETAILS -
REAR STAIRCASE
05/14/2019 -
PERMIT SET
A.405
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE: 1/4" = 1'-0" DRAWING REF: A.1111A
ENLARGED FIRST FLOOR PLAN
REAR ENTRANCE
KEYNOTES
SCALE:6E PERSPECTIVE
SCALE:1 1/2" =1'-0"DRAWING REF: A.201 5A SECTION -REAR ENTRANCE
SCALE:1/4" = 1'-0"DRAWING REF:A.4052BELEVATION -REAR ENTRANCE
SCALE:1/4" = 1'-0"DRAWING REF:A.405 3B ELEVATION -REAR ENTRANCE
SCALE:1/4" = 1'-0"DRAWING REF:A.4053CELEVATION -REAR ENTRANCE
SCALE:1 1/2" =1'-0"DRAWING REF: A.4056BSECTION -REAR ENTRANCE
SCALE: 1 1/2" = 1'-0" DRAWING REF: A.4054BENLARGEDPLAN DETAIL
SCALE:1 1/2" =1'-0"DRAWING REF: A.405 6A SECTION -REAR ENTRANCE
SCALE:1/4" = 1'-0"3A
ENLARGED SECOND FLOOR PLAN
REAR ENTRANCE
SCALE: 1/4" = 1'-0"2A
ENLARGED FIRST FLOOR PLAN
REAR ENTRANCE RCP
A
A
A
A
A
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
07/16/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
A.406 1C
A.406
4C
A.4063C
BIN 1
BIN 2
CART 2
CART 1
STEEL GATE
EXTENT OF CONCRETE PAD -
FLUSH WITH ADJACENT ASPHALT
CONCRETE PAD
CMU WALL ON
CONCRETE FOOTING
8" HIGH CONCRETE
CURB - EXTEND 8"
INTO INTERIOR 8"18'-1 1/2"15'-6" 8"10 3/4"NEW CURB 2'-1"ALIGN
NEW STORM DROP INLET &
GRATE (CB-2) -GC TO TIE INTO
EXISTING STORM SEWER -
PROVIDE FULL TRASH CAPTURE
(SEE TRASH CAPTURE LEGEND
ON A.110)
NEW FENCE TO
MATCH EXISTING
EXISTING FENCE & GATE
EQEQ 7'-0"
CL
CL
D
D
D
D
15'-0" 19'-2 3/4"5'-0"D
D
D
TRASH ENCLOSURE
240 SF
D 6'-0"METAL ROOF & FRAME
PER STRUCTURAL
STEEL POST
STUCCO FINISH
OVER CMU WALL ON
CONCRETE FOOTING
1'-0"1'-0"
STEEL GATE &
HINGES WELDED TO
STEEL POST
GATE B.O.D. -AMETCO ROLLING CANTILEVER GATE (GALV. STEEL)NATURAL GRADE TO TOP OF ROOF9'-9"D
DCLEAR8'-6"STEEL POST - SEE
STRUCTURAL
METAL ROOF &
FRAME - SLOPE 1/4"
PER FOOT
STUCCO FINISH
OVER CMU WALL ON
CONCRETE FOOTING
1'-0"
1'-0"
METAL GUTTER &
DOWNSPOUT
NATURAL GRADE TO TOP OF ROOF9'-9"D
METAL ROOF &
FRAME - SLOPE 1/4"
PER FOOT
STUCCO FINISH
OVER CMU WALL ON
CONCRETE FOOTING
METAL GUTTER &
DOWNSPOUT
CLEAR8'-6"NATURAL GRADE TO TOP OF ROOF9'-9"D
D
EXISTING WOOD TRASH
ENCLOSURE TO BE DEMOLISHED
6'-9" 10'-9 1/4" 5'-6"11'-8 1/4" 5'-6"EXISTING WOOD TRASH
ENCLOSURE TO BE DEMOLISHED 5'-6"2 3'-1 1 1/4"
EXISTING WOOD TRASH
ENCLOSURE TO BE
DEMOLISHED
EXISTING FENCE
TO REMAIN
A.406 2D
A.406
4D
A.406 3D 23'-11 1/4"11'-8 1/4"6'-9"2'-7"10'-9 1/4"EXISTING FENCE
TO REMAIN
TRASH ENCLOSURE WOOD
FENCE TO BE DEMOLISHED
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:54:19 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
TRASH ENCLOSURE
DETAILS
05/14/2019 -
PERMIT SET
A.406
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
C 1 1 /20/2 01 9 BUILDING PERMIT REVIEW -
REVISION #3
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
SCALE:1/4" = 1'-0"DRAWING REF: A.1102AENLARGEDPLAN -TRASH ENCLOSURE
SCALE:1/4" = 1'-0"DRAWING REF: A.4061CELEVATION -TRASH ENCLOSURE FRONT
SCALE:1/4" = 1'-0"DRAWING REF: A.4064CELEVATION -TRASH ENCLOSURE SIDE
SCALE:1/4" = 1'-0"DRAWING REF: A.4063CELEVATION -TRASH ENCLOSURE REAR
SCALE:1/4" = 1'-0"DRAWING REF:A.4063DELEVATION -EXISTING TRASH ENCLOSURE REAR
SCALE:1/4" = 1'-0"DRAWING REF:A.4064DELEVATION -EXISTING TRASH ENCLOSURE SIDE
SCALE:1/4" = 1'-0"DRAWING REF:A.4062DELEVATION -EXISTING TRASH ENCLOSURE FRONT
D
SCALE: 1/8" = 1'-0"DRAWING REF:D.1106DDEMOLITIONPLAN-EXISTING TRASH ENCLOSURE
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
DN
DN
02.41.19.64
02.41.19.64 (30 TOTAL COURTYARD - GC TO VIF)
(18 TOTAL EXTERIOR - GC TO VIF)
02.41.19.60
02.41.19.60
02.41.19.60
02.41.19.71
02.41.19.72
02.41.19.72
02.41.19.73
02.41.19.78
PUBLIC RIGHT OF WAY/
PUBLIC SIDEWALK
N WOLFE ROAD
PUBLIC SIDEWALK
DEMOLISH PORTION OF EXISTING CHAIN LINK
FENCE EXTENDING BEYOND WOOD FENCE
EXISTING TO REMAIN "DOG
EAR" WOOD PRIVACY FENCE
(+/- 6' HIGH)
02.41.19.80
02.41.19.80
A.406
6D
D
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:54:21 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
DEMOLITION - SITE PLAN
05/14/2019 -
PERMIT SET
D.110
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:1/16" = 1'-0"DRAWING REF: -A.404a6ADEMOLITIONPLAN -SITE
KEYNOTES
02.41 .1 9.60 REMOVE LANDSCAPING AS REQUIRED FOR CONSTRUCTION
02.41 .1 9.64 REMOVE BOLLARD LIGHTS AND PREP TO RECEIVE NEW LIGHT FIXTURE.
REFER TO ELECTRICAL DRAWINGS FOR DETAILS
02.41 .1 9.71 REMOVE BACK LIGHTED SIGNAGE. RETURN WIRING BACK TO SOURCE.
PATCH END REPAIR ADJACENT SURFACES AS REQUIRED. REFER TO
ELECTRICAL DRAWINGS FOR DETAILS
02.41 .1 9.72 REMOVE EXISTING SIGNAGE. KEEP AND PROTECT POWER CONNECTION
FOR FUTURE SIGNAGE. REFER TO ELECTRICAL DRAWINGS FOR DETAILS
02.41 .1 9.73 *ADD ALT* PREP AS REQUIRED FOR NEW BICYCLE PARKING
02 .41 .1 9.78 DEMOLISH EXISTING TRASH ENCLOSURE
02.41 .1 9.80 DEMOLISH EXISTING ENTRY CANOPY AND SIDEWALLS
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
C 1 1 /20/2 01 9 BUILDING PERMIT REVIEW -
REVISION #3
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
NSWE100.00°
D
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
DN
DN
J
J
J
C
CCCC
D.201
6A
D.201
6B
D.201 5C
D.2015E
6B
3E3C D.202
6A
02.41.19.53
02.41.19.53
02.41.19.61
02.41.19.52
02.41.19.52
02.41.19.59
02.41.19.58
02.41.19.50
02.41.19.50
02.41.19.56
02.41.19.52
02.41.19.53
02.41.19.55 02.41.19.57
02.41.19.53
02.41.19.60
02.41.19.59
02.41.19.63
02.41.19.63
02.41.19.59
02.41.16.01
02.41.16.01
02.41.19.54
02.41.19.62
02.41.19.52
02.41.19.52
02.41.19.52
02.41.19.52
02.41.19.52
02.41.19.71
02.41.19.75
02.41.19.76
02.41.19.74
A.203
6A
A.203
6B
A.203 4C
A.2034E
6B
3E 3C A.204
6A
K1 -R
112
QQ1 -R
116
K1 -L
118
K1 -L
119
K1 -R
120
K1C-R
121
QQ1 -L
122
QQARI-L
123
QQ1 -R
124
QQ1 -R
125
QQ2C-L
126
QQ1 -L
127
KS1 -L
128
K1C-R
129
K1C-L
131
K1 -R
133
K1 -L
135
K1 -R
137
K1 -L
139
K1C-R
141
KS1 -R
142
QQ1C-L
143
QQ2C-R
144
QQ1C-R
145
QQ1 -L
146
KA1 -L
147
K1 -R
148
K1 -R
149
K1 -L
150
K1 -R
152
QQ1 -L
154
QQ1 -R
156
K1 -L
155
K1 -R
157
K1 -L
158
K2C-R
160
KSARI-L
162
K1 -R
101
K1 -L
103
K1C-R
105
K1C-L
107
DDS2-R
108
K1 -R
109
K2C-L
110
K1 -L
111
K1 -R
115
QQ1 -L
114
LOBBY
1.10
EMPLOYEE
LOUNGE
1.11
MEETING
ROOM A
1.12
MEETING
ROOM B
1.13
GUEST
LAUNDRY
1.14
FITNESS
ROOM
1.15
VESTIBULE
1.10A
CORRIDOR
1.04
ELEV LOBBY
1.04A
CORRIDOR
1.03
ICE
1.03A
CORRIDOR
1.01
ELEVATOR
LOBBY
1.01B
CORRIDOR
1.02
STAIR #1
ST1.01
STAIR #2
ST2.01
ELEV #2
EL.2
ELEV #1
EL.1
STAIR #3
ST3.01
STAIR #4
ST4.01
DEMO WORK
POCHE LEGEND - DEMO
LANDSCAPE DEMO
NIC
NOT FOR
CONSTRUCTION
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 7/2/2019 5:54:13 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
DEMOLITION - 1ST
FLOOR PLAN
05/14/2019 -
PERMIT SET
D.111
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:3/32" = 1'-0"DRAWING REF:A.401b6ADEMOLITIONPLAN -OVERALL
GROUND FLOOR
KEYNOTES
02 .41 .1 6.01 REMOVE COLUMNS AND CONCRETE FOOTINGS. REFER TO STRUCTURAL
DRAWINGS FOR DETAILS.
02 .41 .1 9.50 REMOVE PORTE COCHERE & PORTE COCHERE LIGHTING. REFER TO
ELECTRICAL DRAWINGS FOR DETAILS
02 .41 .1 9.52 REMOVE DOWN SPOUTS AND DISCONETCT FOR EXISTING TO REMAIN
UNDERGROUND DRAINAGE
02.41 .1 9.53 REMOVE FINISH AND SUBSTRATE TO EXTEND SHOWN
02.41 .1 9.54 SALVAGE BANQUET SEATING AND STORE FOR REUSE
02 .41 .1 9.55 REMOVE FLOORING AT EXTEND SHOWN
02.41 .1 9.56 REMOVE BAY WINDOWS
02.41 .1 9.57 REMOVE CEILING AT BAY WINDOWS
02 .41 .1 9.58 REMOVE STOREFRONT
02 .41 .1 9.59 SALVAGE AUTOMATIC DOOR OPENER / CARD READER DOOR HARDWARE
02 .41 .1 9.60 REMOVE LANDSCAPING AS REQUIRED FOR CONSTRUCTION
02 .41 .1 9.61 REMOVE LIGHT FIXTURE. REFER TO ELECTRICAL DRAWINGS
02 .41 .1 9.62 EXISTING TO REMAIN WALL MOUNTED FIRE DEPARTMENT BOX. KEEP AND
PROTECT DURING CONSTRUCTION
02 .41 .1 9.63 REMOVE WALLS AND ROOF AT REAR ENTRANCE.
02.41 .1 9.71 REMOVE BACK LIGHTED SIGNAGE. RETURN WIRING BACK TO SOURCE.
PATCH END REPAIR ADJACENT SURFACES AS REQUIRED. REFER TO
ELECTRICAL DRAWINGS FOR DETAILS
02 .41 .1 9.74 EXISTING TO REMAIN HVAC UNIT. KEEP AND PROTECT DURING
CONSTRUCTION. MODIFY ELECTRICAL CONNECTIONS AND LINES AS
REQUIRED FOR NEW CONSTRUCTION
02 .41 .1 9.75 REMOVE CONCRETE SIDEWALK AS REQUIRED FOR NEW CONSTRUCTION
02 .41 .1 9.76 REMOVE STOOP CONCRETE AS REQUIRED FOR NEW CONSTRUCTION
A
A
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
07/16/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
D.201
6A
D.201
6B
D.201 5C
D.2015E
6B
3E3C D.202
6A
02.41.19.51
02.41.19.67
02.41.19.66
02.41.19.68
02.41.19.51
02.41.19.67
02.41.19.51
02.41.19.63
02.41.19.63
02.41.19.51
02.41.19.66
02.41.19.50
02.41.19.50
02.41.19.51
02.41.19.51
02.41.19.51
02.41.19.51
A
A
A.203
6A
A.203
6B
A.203 4C
A.2034E
6B
3E 3C A.204
6A
DEMO WORK
POCHE LEGEND - DEMO
LANDSCAPE DEMO
NIC
NOT FOR
CONSTRUCTION
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 7/2/2019 5:54:15 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
DEMOLITION PLAN -
ROOF
05/14/2019 -
PERMIT SET
D.114
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:3/32" = 1'-0"DRAWING REF: A.403c6ADEMOLITIONROOFPLAN
KEYNOTES
02.41 .1 9.50 REMOVE PORTE COCHERE & PORTE COCHERE LIGHTING. REFER TO
ELECTRICAL DRAWINGS FOR DETAILS
02.41 .1 9.51 REMOVE ROOF FACIA AND GUTTERS TO EXTEND SHOW.
02.41 .1 9.63 REMOVE WALLS AND ROOF AT REAR ENTRANCE.
02.41 .1 9.66 REMOVE TERRACOTTA ROOF SHINGLES AND STORE FOR REUSE AND
REPAIRS. EXISTING ROOF DECK TO REMAIN
02.41 .1 9.67 REMOVE TERRACOTTA ROOF SHINGLES AND STORE FOR REUSE AND
REPAIRS. REMOVE ROOF DECK AND TRUSSES AS REQUIRED FOR NEW
CONSTRUCTION
02.41 .1 9.68 REMOVE SKYLIGHT.
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
07/16/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
02.41.19.63
02.41.19.52
02.41.19.67
02.41.19.51
02.41.19.53
02.41.19.51
02.41.16.01
02.41.19.50
02.41.19.69
02.41.19.69
02.41.19.69
02.41.19.65
02.41.19.71
TYP.
02.41.19.69
NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 45'-6"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 31'-8 1/2"NATURAL GRADE TO TOP OF PLATE TO BE DEMOLISHED+/- 29'-2 1/2"NATURAL GRADE TO TOP OF PLATE TO BE DEMOLISHED+/- 12'-10 3/4"NATURAL GRADE TO TOP OF PORTE COCHERE ROOF RIDGE TO BE DEMOLISHED+/- 19'-4 3/4"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 33'-1 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 47'-6 1/2"31.00.00.A
02.41.19.67
02.41.19.51
02.41.19.53
02.41.19.51
02.41.19.50
02.41.16.01
02.41.19.52
02.41.19.69
26.56.19.B
02.41.19.63
3B
D.301
2B
D.301
02.41.19.69
02.41.19.69
02.41.19.69
02.41.19.65 TYP.
02.41.19.69
NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 42'-8"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/2"NATURAL GRADE TO TOP OF ROOF RIDGE TO BE DEMOLISHED+/- 32'-3 1/2"NATURAL GRADE TO TOP OF EXISTING / TO BE DEMOLSIHED PLATE+/- 27'-2 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 11'-10 3/4"NATURAL GRADE TO TOP OF PORTE COCHERE ROOF RIDGE TO BE DEMOLISHED+/- 18'-4 3/4"31.00.00.A
02.41.19.67
02.41.19.52
02.41.19.51
02.41.19.69
02.41.19.51
02.41.16.01 02.41.19.56 02.41.19.52
02.41.19.66
02.41.19.68
02.41.19.67
02.41.19.51
02.41.19.53
2A
D.301
02.41.19.69 02.41.19.69
02.41.19.69
02.41.19.52
4A
D.301
NATURAL GRADE TO TOP OF PLATE OF PORTE COCHERE TO BE DEMOLISHED+/- 11'-10 3/4"NATURAL GRADE TO TOP OF PORTE COCHERE ROOF RIDGE TO BE DEMOLISHED+/- 18'-5 1/4"NATURAL GRADE TO TOP OF EXISTINGPLATE TO BE DEMOLISHED+/- 13'-10 3/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE TO BE BUILD OVER+/- 23'-10 3/4"31.00.00.A
6B
D.301
02.41.19.63
02.41.19.52
02.41.19.52
02.41.19.63
02.41.19.69
02.41.19.69
02.41.19.69
02.41.19.69
02.41.19.53
02.41.19.69
02.41.19.53
NATURAL GRADE TO TOP OF EXISTING PLATE+/- 12'-10 3/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 19'-3 3/4"31.00.00.A
DEMO WORK
POCHE LEGEND - DEMO
LANDSCAPE DEMO
NIC
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:54:28 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
DEMOLITION - EXTERIOR
ELEVATIONS
05/14/2019 -
PERMIT SET
D.201
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:3/32" = 1'-0"DRAWING REF:A4106ADEMOLITIONELEVATION- EAST
SCALE:3/32" = 1'-0"DRAWING REF:A.4066BDEMOLITIONELEVATION -WEST
SCALE:3/32" = 1'-0"DRAWING REF:A.401a5CDEMOLITIONELEVATION
-NORTH
SCALE:3/32" = 1'-0"DRAWING REF:D.1115EDEMOLITIONELEVATION -SOUTH
KEYNOTES
02.41.16.01 REMOVE COLUMNS AND CONCRETE FOOTINGS. REFER TO STRUCTURAL
DRAWINGS FOR DETAILS.
02 .41 .1 9.50 REMOVE PORTE COCHERE & PORTE COCHERE LIGHTING. REFER TO
ELECTRICAL DRAWINGS FOR DETAILS
02.41.19.51 REMOVE ROOF FACIA AND GUTTERS TO EXTEND SHOW.
02 .41 .1 9.52 REMOVE DOWN SPOUTS AND DISCONETCT FOR EXISTING TO REMAIN
UNDERGROUND DRAINAGE
02 .41 .1 9.53 REMOVE FINISH AND SUBSTRATE TO EXTEND SHOWN
02 .41 .1 9.56 REMOVE BAY WINDOWS
02 .41 .1 9.63 REMOVE WALLS AND ROOF AT REAR ENTRANCE.
02 .41 .1 9.65 REMOVE EXTERIOR GRADE WALL SCONE AND PREP TO RECEIVE NEW.
REFER TO ELECTRICAL DRAWINGS FOR DETAILS
02 .41 .1 9.66 REMOVE TERRACOTTA ROOF SHINGLES AND STORE FOR REUSE AND
REPAIRS. EXISTING ROOF DECK TO REMAIN
02 .41 .1 9.67 REMOVE TERRACOTTA ROOF SHINGLES AND STORE FOR REUSE AND
REPAIRS. REMOVE ROOF DECK AND TRUSSES AS REQUIRED FOR NEW
CONSTRUCTION
02 .41 .1 9.68 REMOVE SKYLIGHT.
02 .41 .1 9.69 PREPARE AS REQUIRED EXISTING TO REMAIN EIFS, TRIMS, FASCIAS,
GUTTERS, RAIN LEADERS, HANDRAILS, GUARDRAILS, PTAC COVERS ETC TO
RECEIVE NEW FINISH
02 .41 .1 9.71 REMOVE BACK LIGHTED SIGNAGE. RETURN WIRING BACK TO SOURCE.
PATCH END REPAIR ADJACENT SURFACES AS REQUIRED. REFER TO
ELECTRICAL DRAWINGS FOR DETAILS
26.56.1 9.B OFCI EXTERIOR GRADE SCONE LIGHT. INSTALL IN EXISTING LIGHT LOCATION.
REFER TO ELECTRICAL DRAWINGS FOR DETAILS
31.00.00.A NATURAL GRADE - AS PER GRADING PLAN DATED 10/25/86 BY SANDIS AND
ASSOCIATES INC. ENGINEERS, SURVEYORS AND PLANNERS
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
D
D
D
D
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
02.41.16.01
02.41.19.50
02.41.19.51
02.41.19.53
02.41.19.66
02.41.19.51
02.41.19.67
02.41.19.69
02.41.19.69 02.41.19.63
5B
D.301
02.41.19.65
02.41.19.65 02.41.19.65
02.41.19.65
02.41.19.65
02.41.19.65
TYP.
TYP.
02.41.19.69
02.41.19.52
NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 27'-2 1/2"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 43'-6"44'-11"02.41.19.63
02.41.19.69
02.41.19.69
02.41.19.65
02.41.19.52
02.41.19.67
02.41.19.51
02.41.19.50
02.41.16.01
02.41.19.5102.41.19.65
02.41.19.6502.41.19.65
02.41.19.65
02.41.19.65
02.41.19.65
02.41.19.52
TYP.TYP.TYP.
02.41.19.69
31.00.00.ANATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/2"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 42'-8"44'-11"02.41.19.69 02.41.19.69 02.41.19.69
NATURAL GRADE TO TOP OF EXISTING PLATE+/- 11'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 18'-0 1/2"18'-1"02.41.19.69
02.41.19.6902.41.19.69
02.41.19.6502.41.19.65 02.41.19.65
02.41.19.69
TYP.NATURAL GRADE TO TOP OF EXISTING PLATE+/- 12'-8"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 22'-10 1/2"26'-7"DEMO WORK
POCHE LEGEND - DEMO
LANDSCAPE DEMO
NIC
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:54:31 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
DEMOLITION - EXTERIOR
ELEVATIONS -
COURTYARD
05/14/2019 -
PERMIT SET
D.202
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:3/32" = 1'-0"DRAWING REF:A.401a6ADEMOLITIONELEVATION - EAST COURTYARD
SCALE:3/32" = 1'-0"DRAWING REF:A0066BDEMOLITIONELEVATION- WEST COURTYARD
SCALE:3/32" = 1'-0"DRAWING REF:A4233EDEMOLITIONELEVATION- SOUTH COURTYARD
SCALE:3/32" = 1'-0"DRAWING REF:D.1113CDEMOLITIONELEVATION - NORTH COURTYARD
KEYNOTES
02.41 .1 6.01 REMOVE COLUMNS AND CONCRETE FOOTINGS. REFER TO STRUCTURAL
DRAWINGS FOR DETAILS.
02.41 .1 9.50 REMOVE PORTE COCHERE & PORTE COCHERE LIGHTING. REFER TO
ELECTRICAL DRAWINGS FOR DETAILS
02.41 .1 9.51 REMOVE ROOF FACIA AND GUTTERS TO EXTEND SHOW.
02 .41 .1 9.52 REMOVE DOWN SPOUTS AND DISCONETCT FOR EXISTING TO REMAIN
UNDERGROUND DRAINAGE
02 .41 .1 9.53 REMOVE FINISH AND SUBSTRATE TO EXTEND SHOWN
02 .41 .1 9.63 REMOVE WALLS AND ROOF AT REAR ENTRANCE.
02 .41 .1 9.65 REMOVE EXTERIOR GRADE WALL SCONE AND PREP TO RECEIVE NEW.
REFER TO ELECTRICAL DRAWINGS FOR DETAILS
02.41 .1 9.66 REMOVE TERRACOTTA ROOF SHINGLES AND STORE FOR REUSE AND
REPAIRS. EXISTING ROOF DECK TO REMAIN
02 .41 .1 9.67 REMOVE TERRACOTTA ROOF SHINGLES AND STORE FOR REUSE AND
REPAIRS. REMOVE ROOF DECK AND TRUSSES AS REQUIRED FOR NEW
CONSTRUCTION
02 .41 .1 9.69 PREPARE AS REQUIRED EXISTING TO REMAIN EIFS, TRIMS, FASCIAS,
GUTTERS, RAIN LEADERS, HANDRAILS, GUARDRAILS, PTAC COVERS ETC
TO RECEIVE NEW FINISH
31.00.00.A NATURAL GRADE - AS PER GRADING PLAN DATED 10/25/86 BY SANDIS AND
ASSOCIATES INC. ENGINEERS, SURVEYORS AND PLANNERS
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
C 1 1 /20/2 01 9 BUILDING PERMIT REVIEW -
REVISION #3
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
D
D
D
D
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
1ST FLOOR
0' - 0"
2ND FLOOR
9' - 3"
3RD FLOOR
18' - 7"
02.41.19.66
02.41.19.52
02.41.19.56
1ST FLOOR
0' - 0"
2ND FLOOR
9' - 3"
3RD FLOOR
18' - 7"
T.O. PLATTE
26' - 9 3/4"
HIGH EAVE
30' - 9 3/4"
LOW EAVE
28' - 3 3/4"
02.41.19.67
02.41.19.53
02.41.19.51
02.41.19.70
02.41.19.70
1ST FLOOR
0' - 0"
2ND FLOOR
9' - 3"
3RD FLOOR
18' - 7"
T.O. PLATTE
26' - 9 3/4"
HIGH EAVE
30' - 9 3/4"
LOW EAVE
28' - 3 3/4"
02.41.19.53
02.41.19.51
1ST FLOOR
0' - 0"
2ND FLOOR
9' - 3"
3RD FLOOR
18' - 7"
T.O. PLATTE
26' - 9 3/4"
HIGH EAVE
30' - 9 3/4"
LOW EAVE
28' - 3 3/4"
02.41.19.69
02.41.19.69
D
1ST FLOOR
0' - 0"
2ND FLOOR
9' - 3"
3RD FLOOR
18' - 7"
T.O. PLATTE
26' - 9 3/4"
HIGH EAVE
30' - 9 3/4"
LOW EAVE
28' - 3 3/4"
02.41.19.59
02.41.19.63
02.41.19.70
02.41.19.70
1ST FLOOR
0' - 0"
2ND FLOOR
9' - 3"
3RD FLOOR
18' - 7"
02.41.19.50
02.41.19.51
02.41.19.53
DEMO WORK
POCHE LEGEND - DEMO
LANDSCAPE DEMO
NIC
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/21/2020 11:54:34 AM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvt
DEMOLITION WALL
SECTIONS
05/14/2019 -
PERMIT SET
D.301
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
KEYNOTES
02 .41 .1 9.50 REMOVE PORTE COCHERE & PORTE COCHERE LIGHTING. REFER TO
ELECTRICAL DRAWINGS FOR DETAILS
02 .41 .1 9.51 REMOVE ROOF FACIA AND GUTTERS TO EXTEND SHOW.
02 .41 .1 9.52 REMOVE DOWN SPOUTS AND DISCONETCT FOR EXISTING TO REMAIN
UNDERGROUND DRAINAGE
02 .41 .1 9.53 REMOVE FINISH AND SUBSTRATE TO EXTEND SHOWN
02 .41 .1 9.56 REMOVE BAY WINDOWS
02 .41 .1 9.59 SALVAGE AUTOMATIC DOOR OPENER / CARD READER DOOR HARDWARE
02 .41 .1 9.63 REMOVE WALLS AND ROOF AT REAR ENTRANCE.
02 .41 .1 9.66 REMOVE TERRACOTTA ROOF SHINGLES AND STORE FOR REUSE AND
REPAIRS. EXISTING ROOF DECK TO REMAIN
02 .41 .1 9.67 REMOVE TERRACOTTA ROOF SHINGLES AND STORE FOR REUSE AND
REPAIRS. REMOVE ROOF DECK AND TRUSSES AS REQUIRED FOR NEW
CONSTRUCTION
02 .41 .1 9.69 PREPARE AS REQUIRED EXISTING TO REMAIN EIFS, TRIMS, FASCIAS,
GUTTERS, RAIN LEADERS, HANDRAILS, GUARDRAILS, PTAC COVERS ETC TO
RECEIVE NEW FINISH
02 .41 .1 9.70 EXISTING TO REMAIN WINDOW AND/OR DOOR. KEEP AND PROTECT DURING
CONSTRUCTION
SCALE: 1/4" = 1'-0"DRAWING REF: A.2122ADEMOLITION- LOBBY - WALL SECTION
SCALE: 1/4" = 1'-0"DRAWING REF: A.2113BDEMOLITION -FRONT ENTRANCE - WALL SECTION
SCALE: 1/4" = 1'-0"DRAWING REF: A.2145BDEMOLITION -FRONT ENTRANCE ROOF - WALL SECTION
SCALE: 1/4" = 1'-0"DRAWING REF: A.2112BDEMOLITION -SIDE ENTRANCE - WALL SECTION
SCALE: 1/4" = 1'-0"DRAWING REF: A.2116BDEMOLITION - REAR ENTRANCE - WALL SECTION
SCALE: 1/4" = 1'-0"DRAWING REF: A.2124ADEMOLITION- LOBBY - WALL SECTION
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
D 02/07/2 020 BUILDING PERMIT REVIEW -
REVISION #4
02/21/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
1. PROVIDE WORK IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL
ORDINANCES, AND AS APPROVED BY THE LOCAL AUTHORITY HAVING
JURISDICTION.
2. OBTAIN PERMITS AND PAY SUCH FEES AS MAY BE NECESSARY FOR
INSPECTIONS, TESTS, AND OTHER SERVICES NECESSARY FOR THE COMPLETION
OF THE WORK.
3. PROVIDE LABOR, MATERIAL, AND OTHER SERVICES AS MAY BE NECESSARY TO
PROVIDE A COMPLETE AND FUNCTIONING SYSTEM.
4. NOTIFY THE ARCHITECT/ENGINEER AND RESOLVE ANY ISSUES EXPERIENCED
DURING THE COURSE OF THE WORK PRIOR TO EXECUTION OF THE WORK.
5. PRODUCTS SPECIFIED IN THE DRAWINGS BY MANUFACTURER AND/OR MODEL
NUMBER ARE NOT LIMITED TO THE NAMED MANUFACTURER. PROVIDE
PRODUCTS BY THE NAMED MANUFACTURER OR EQUIVALENT PRODUCTS BY
OTHER MANUFACTURERS
6. SUBMIT SHOP DRAWINGS FOR THE FOLLOWING ITEMS:
A. LIGHT FIXTURES
B. PANELBOARDS / CIRCUIT BREAKERS
C. SAFETY SWITCHES
D. TRANSFORMERS
E. WIRING DEVICES
F. CONDUCTORS
G. CONDUIT
H. ALL OTHER ITEMS SPECIFIED BY MODEL NUMBER ON DRAWINGS
7. SHOP DRAWINGS MUST BE APPROVED BY ENGINEER PRIOR TO PURCHASE. IF A
SUBSTITUTION IS PROPOSED, BE PREPARED TO PROVIDE SAMPLES FOR
EVALUATION.
8. PROVIDE MATERIAL WITHIN ONE YEAR OF MANUFACTURE, BEARING A U.L. LABEL,
AND LISTED FOR ITS INSTALLED APPLICATION.
9. PROVIDE MAJOR COMPONENTS OF THE ELECTRICAL SYSTEM BY THE SAME
MANUFACTURER.
10. USE MOUNTING HEIGHTS INDICATED ON THE LEGEND EXCEPT WHERE
INDICATED ON THE DRAWINGS. MOUNTING HEIGHTS ARE MEASURED FROM THE
MIDDLE OF WALL MOUNTED DEVICES AND FROM THE BOTTOM OF PENDENT
MOUNTED DEVICES.
11. ASSEMBLE, HANG, AND CONNECT LIGHTING FIXTURES FURNISHED COMPLETE
WITH SOCKETS, TRIM HANGERS, SUPPORTS, ETC, AS REQUIRED FOR A
COMPLETE INSTALLATION. MOUNT LIGHT FIXTURES SUPPORTED
INDEPENDENTLY OF SUSPENDED CEILING COMPONENTS.
12. PROVIDE "LOCKING" TYPE DEVICES ON CIRCUIT BREAKERS CONNECTED TO
EMERGENCY LIGHTING, NIGHT LIGHTING, FIRE ALARM, AND SECURITY SYSTEMS.
13. IN FINISHED SPACES: FLUSH MOUNT LIGHT SWITCHES, RECEPTACLES, AND
TELECOMMUNICATIONS OUTLETS, ROUTE RACEWAYS CONCEALED.
14. PROVIDE MOTOR OVERLOAD DEVICES IN STARTERS BASED ON NAMEPLATE
RATING ON THE MOTORS BEING INSTALLED.
15. PROVIDE "HACR" TYPE CIRCUIT BREAKERS FOR CIRCUITS THAT SERVE HEATING,
AIR CONDITIONING, OR REFRIGERATION EQUIPMENT.
16. PROVIDE MINIMUM #10 NEUTRAL CONDUCTOR FOR MULTI-WIRE RECEPTACLE
BRANCH CIRCUITS.
17. PROVIDE SPLICES IN OUTLET OR JUNCTION BOXES ONLY.
18. PROVIDE UPDATED TYPE WRITTEN CIRCUIT DIRECTORY IN PLASTIC SLEEVE FOR
EACH PANELBOARD AFFECTED BY THE WORK.
19. PROVIDE U.L. APPROVED FIRE STOP SYSTEMS FOR PENETRATIONS THROUGH
FIRE AND SMOKE PARTITIONS TO MAINTAIN THE RATING OF THE PARTITION.
20. BOX-IN DEVICES ON FIRE/SMOKE PARTITIONS WITH FIRE RATED MATERIAL.
21. PROVIDE "AS-BUILT" DRAWINGS TO THE OWNER AT CONTRACT CLOSEOUT.
22. GUARANTEE WORK AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER OWNER
ACCEPTANCE.
23. PERFORM ALL WORK IN ACCORDANCE WITH CALIFORNIA NATIONAL ELECTRIC
CODE (2014), UNIFORM STATEWIDE BUILDING CODE (2012), ADA STANDARDS FOR
ACCESSIBLE DESIGN (2010), AND CONSTRUCTION AND PROFESSIONAL SERVICES
MANUAL, REV 0 (2013).
24. CONTRACTOR SHALL COMPLY WITH AND MAINTAIN A COPY OF CALIFORNIA
STATE FIRE PROTECTION CODE (2012) AND NFPA 241-2000 "STANDARD FOR
SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS"
ON SITE.
25. NOTIFY CONSTRUCTION MANAGER, OWNER , FIRE DEPARTMENT, AND
AUTHORITY HAVING JURISDICTION A MINIMUM OF SEVEN DAYS PRIOR TO ANY
FIRE ALARM OR SPRINKLER SYSTEM SERVICE INTERRUPTION. PROVIDE FIRE
WATCH IN ACCORDANCE WITH CALIFORNIA STATEWIDE FIRE PREVENTION CODE
(2012), PARAG RAPH 901.7. SERVICE INTERRUPTIONS SHALL BE CONFINED TO
TIMES WHEN THE BUILDING IS NORMALLY UNOCCUPIED.
1. PROJECT DESCRIPTION:
EXTERIOR RENOVATION
2. APPLICABLE CODES:
CALIFORNIA BUILDING CODE, 2016
CALIFORNIA ELECTRICAL CODE, 2016 EDITION
CALIFORNIA ENERGY CODE, 2016 EDITION
CALIFORNIA GREEN BUILDING CODE 2016 EDITION
CUPERTINO MUNICIPAL CODE
3. EXISTING USE GROUP: A-3 / B / R-1 (NO CHANGE)
4. CONSTRUCTION CLASSIFICATION:TYPE VA ( NO CHANGE)
5. NUMBER OF STORIES: 3
6. BUILDING HEIGHT: 44' - 6"
1. DEMOLITION DRAWINGS ARE PROVIDED AS REFERENCE ONLY. DEMOLITION
DRAWINGS ARE BASED ON NON-DESTRUCTIVE FIELD INVESTIGATION AND
EXISTING DRAWINGS.
2. VISIT THE PROJECT SITE AND BECOME FAMILIAR WITH EXISTING FIELD
CONDITIONS PRIOR TO PROCEEDING WITH THE WORK.
3. CLEAN AND REPAIR ALL EQUIPMENT INDICATED FOR REUSE OR SALVAGE.
4. DISPOSE OF, IN A LEGAL MANNER, ALL MATERIALS INDICATED FOR REMOVAL AND
NOT INDICATED FOR REUSE OR SALVAGE.
5. MAINTAIN CONTINUITY OF EXISTING BRANCH CIRCUITS AND FEEDERS NOT
INDICATED FOR REMOVAL BUT MAY BE DISTURBED BY THE WORK. REROUTE
CIRCUITS AS REQUIRED DUE TO THE WORK.
6. EXISTING CONDUIT MAY BE ABANDONED IN THE WALLS, FLOOR SLAB, AND BELOW
GRADE ONLY. REMOVE CONDUITS TO THE SURFACE OF THE WALL/FLOOR AND
PATCH.
7. REMOVE UNUSED CABLING AND CONDUCTORS ALL THE WAY BACK TO THE
SOURCE.
DESCRIPTION
CARD READER, MOUNT +46" AFF, PROVIDE 3/4" EMPTY
CONDUIT TO ACCESSIBLE ABOVE CEILING SPACE
SYMBOL
CR
DESCRIPTION
LIGHT FIXTURE
LIGHT FIXTURE, WALL MOUNT
BOLLARD
SYMBOL
SYMBOL DESCRIPTION
BRANCH CIRCUIT HOMERUN, HATCH MARKS INDICATE TYPE
AND NUMBER OF CONDUCTORS, DASHED LINES INDICATE
UNDER FLOOR/GROUND ROUTING, PROVIDE 3#12 IN 3/4"
CONDUIT UNLESS OTHERWISE INDICATED.
INDICATES PHASE CONDUCTOR
INDICATES NEUTRAL CONDUCTOR
INDICATES GROUNDING CONDUCTOR
JUNCTION BOX, CEILING
ADA PUSHBUTTON
J
RELATED DOCUMENTS
DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING
GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 01
SPECIFICATIONS, APPLY.
260513 - CONDUCTORS AND CABLES
1. PROVIDE COPPER CONDUCTORS, NEMA WC/ICEA S-95-658 TYPE
THHN/THWN-2, TYPE UF, AND TYPE SO.
2. PROVIDE SOLID CONDUCTORS FOR #10 AWG AND SMALLER, STRANDED FOR #
8 AWG AND LARGER.
3. COLOR CODE ALL CONDUCTORS.
260526 - GROUNDING AND BONDING
1. PROVIDE 3/4" DIA X 10'-0" COPPER CLAD GROUND RODS.
2. PROVIDE INSULATED GROUNDING CONDUCTORS WITH ALL FEEDER AND
BRANCH CIRCUITS.
260529 - HANGERS AND SUPPORTS
1. PROVIDE HOT DIP GALVANIZED STEEL SLOTTED SUPPORT SYSTEMS WITH
MFMA-4 FACTORY FABRICATED COMPONENTS FOR FIELD ASSEMBLY.
2. PROVIDE STEEL HANGERS, CLAMPS, AND ASSOCIATED FITTINGS FOR
CONDUIT AND CABLE SUPPORT.
3. ATTACHMENTS
3.1 WOOD - LAG SCREWS.
3.2 CONCRETE - EXPANSION ANCHORS.
3.3 MASONRY - TOGGLE TYPE BOLTS.
3.4 STEEL - BEAM CLAMPS.
3.5 LIGHT STEEL - SHEET METAL SCREWS.
260533 - RACEWAYS AND BOXES
1. METAL CONDUIT
1 .1 GRC - COMPLY WITH ANSI C80 AND UL 6.
1 .2 EMT - COMPLY WITH ANSI C80.3 AND UL 797.
1 .3 FMC - COMPLY WITH UL 1; ZINC-COATED STEEL.
1 .4 LFMC - FLEXIBLE STEEL CONDUIT WITH PVC JACKET, COMPLY WITH UL
360.
1 .5 FITTINGS - COMPLY WITH FB 1 AND UL 514B.
1 .6 FITTING FOR EMT - STEEL SETSCREW.
2. NON-METALLIC CONDUIT
2.1 PVC, SCHEDULE 40 - COMPLY WITH NEMA TC 2 AND UL 651.
3. APPLICATIONS
3.1 OUTDOORS EXPOSED USE GRC, UNDERGROUND USE PVC.
3.2 INDOORS EXPOSED USE GRC, CONCEALED USE EMT.
3.3 CONNECTION TO VIBRATING EQUIPMENT USE LFMC OR FMC.
3.4 PROVIDE MINIMUM 3/4" RACEWAYS.
3.5 PROVIDE PULL STRING IN ALL EMPTY CONDUITS.
260553 - IDENTIFICATION
1. PROVIDE LAMINATED ACRYLIC PLASTIC SIGNS FOR ALL EQUIPMENT,
ENGRAVED LEGEND WITH BLACK LETTERS ON WHITE FACE, PUNCHED OR
DRILLED FOR MECHANICAL FASTENERS.
2. PROVIDE SIGNS DESIGNATING EQUIPMENT IDENTIFICATIONS, SYSTEM
VOLTAGE AND PHASE, AND PPE WARNING.
3. FOR EXTERIOR APPLICATIONS PROVIDE UV STABILIZED SIGNS.
2651 1 6 - FLUORESCENT INTERIOR LIGHTING
1. COMPLY WITH UL 1598 AND ANSI C81.61.
2. PROVIDE ELECTRONIC BALLASTS, UL 935, ANSI C82.1 1 , CLASS A SOUND
RATING, 10% THD, 42KHz OPERATING FREQUENCY, BALLAST FACTOR: 0.88 OR
HIGHER, 0.95 POWER FACTOR OR HIGHER.
3. EMERGENCY FLUORESCENT POWER UNIT - INTERNAL TYPE, MODULAR
BATTERY-INVERTER TO OPERATED ONE LAMP AT 1100 LUMEN OUTPUT,
SEALED NI-CAD BATTERY.
4. LAMPS - 3500 DEGREE K, 20,000 HOURS AVERAGE LIFE, CRI: 85 OR HIGHER.
2651 1 9 - LED INTERIOR LIGHTING
1. COMPLY WITH NEMA LE 4 AND ANSI C79.1 AND C81.61.
2. MINIMUM CRI: 80, CCT: 3000 DEGREES K, L70 LAMP LIFE: 50,000 HOURS.
265617 - FLUORESCENT EXTERIOR LIGHTING
1. COMPLY WITH UL 1598 AND ANSI C81.61.
2. PROVIDE ELECTRONIC BALLASTS, UL 935, ANSI C82.1 1 , CLASS A SOUND
RATING, 10% THD, 42KHz OPERATING FREQUENCY, BALLAST FACTOR: 0.88 OR
HIGHER, 0.95 POWER FACTOR OR HIGHER.
265619 -LED EXTERIOR LIGHTING
1. COMPLY WITH NEMA LE 4 AND ANSI C79.1 AND C81.61.
2. MINIMUM CRI: 80, CCT: 3000 DEGREES K, L70 LAMP LIFE: 50,000 HOURS.
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 1:11:28 PM C:\Users\skruyne\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Electrical_Exterior_R18_skruyne.rvt
LEGEND, SPECS
05/14/2019 -
PERMIT SET
E.001
2.180648.0
GENERAL NOTES
PROJECT INFORMATIONGENERAL DEMOLITION NOTES
SECURITY LEGEND
LIGHTING LEGEND
POWER LEGEND
ABBREVIATIONS
ELECTRICAL SPECIFICATIONS
ELECTRICAL DRAWING LIST
DRAWING NUMBER DRAWING TITLE
E.001 LEGEND, SPECS
E.101 GROUND FLOOR - DEMOLITION
E.102 GROUND FLOOR - NEW WORK
E.201 ELEVATIONS
E.202 ELEVATIONS
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NO. NUMBER
P/BD PANELBOARD
PR PRESENT TO REMAIN
PRI PRIMARY
PVC POLYVINYL CHLORIDE
PWR POWER
RCPT RECEPTACLE
RL RELOCATED
SEC SECURITY
SW SWITCH
SWBD SWITCHBOARD
TELECOM TELECOMMUNICATIONS
TV TELEVISION
TVSS TRANSIENT VOLTAGE SURGE SUPRESSOR
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
V VOLTAGE
W/ WITH
XFER TRANSFER
XFMR TRANSFORMER
EM EMERGENCY
EQ EQUIPMENT
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FC FOOT CANDLE
FT FEET
FVNR FULL VOLTAGE NON-REVERSING
G GROUND
GFCI GROUND FAULT CIRCUIT INTERRUPTING
GFI GROUND FAULT INTERRUPTING
GND GROUND
HP HORSEPOWER
IAW IN ACCORDANCE WITH
ILTG INTERIOR LIGHTING
IN INCHES
KCMIL KILO CIRCULAR MILLS
KVA KILOVOLT AMPS
KW KILOWATTS
KWH KILOWATT HOURS
LED LIGHT EMITTING DIODE
LTG LIGHTING
LTS LIGHTS
MCC MOTOR CONTROL CENTER
MISC MISCELLANEOUS
MTD MOUNTED
MTR MOTOR
N NEUTRAL
1P SINGLE POLE
1PH SINGLE PHASE
2P TWO POLE
3P THREE POLE
3PH THREE PHASE
A AMPERES
A/V AUDIO / VISUAL
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AIC AMPERE INTERRUPTING CAPACITY
AL ALUMINUM
AMP AMPERE
AUTO AUTOMATIC
AWG AMERICAN WIRE GAUGE
BFC BELOW FINISHED CEILING
BFG BELOW FINISHED GRADE
C CONDUIT
C/T CURRENT TRANSFORMER
CATV CABLE TELEVISION
CB CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CF COMPACT FLUORESCENT
CKT CIRCUIT
CU COPPER
DEMO DEMOLITION
DISC DISCONNECT
ELEC ELECTRICAL
ELTG EXTERIOR LIGHTING
LIGHTING FIXTURE SCHEDULE
TYPE MANUFACTURER MODEL VOLTAGE
LAMP INPUT LOAD MOUNTING COMMENTSQTY WATTS TYPE
BG EATON LIGHTING EON-B1-LED-B2-4000-UNV-T4-DI
MELV-BK-42-EDGE 120 V 1 16 W LED 16 VA BOLLARD
W1 EATON LIGHTING 673-16-WP-I3/830-UNV-MB 120 V 1 20 W LED 20 VA WALL
Z102 EATON LIGHTING LDSQ4B20D010TR-EU4B1020804
0-4LSBQ1MB-HB26 120 V 1 22 W LED 22 VA RECESSED
05/14/2019
10605 N WOLFE RD, CUPERTINO, CA 95014
COURTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
CR CR
CRCRCRJ
J
26.18
26.22
TYPICAL
26.1
26.19
TYPICAL
26.19
TYPICAL
26.19
TYPICAL
26.19
TYPICAL
26.1
26.19
TYPICAL
26.23
TYPICAL
26.24
26.24
TYPICAL
TYPICAL
26.19
TYPICAL
26.1
26.34
26.34
26.34
26.2
26.2
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 1:11:32 PM C:\Users\skruyne\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Electrical_Exterior_R18_skruyne.rvt
GROUND FLOOR -
DEMOLITION
05/14/2019 -
PERMIT SET
E.101
2.180648.0
KEYNOTES
26.1 REMOVE EXISTING LIGHT FIXTURE; RETAIN EXISTING CIRCUIT FOR REUSE
26.2 REMOVE EXISTING RECEPTACLE; RETAIN EXISTING CIRCUIT FOR REUSE.
26.1 8 REMOVE EXISTING LIGHT FIXTURES AND ALL ASSOCIATED CONDUIT AND WIRING
LOCATED AT PORTE COCHERE. TURN OVER EXISTING FIXTURES TO OWNER.
26.1 9 REMOVE EXISTING BOLLARD. REUSE EXISTING CONDUIT, WIRING, CIRCUIT, AND
CONTROLS FOR REPLACEMENT BOLLARD. CONTRACTOR TO FIELDS VERIFY.
TURN OVER EXISTING FIXTURE TO OWNER.
26.2 2 REMOVE EXISTING LIGHT FIXTURES AND RELOCATE AS SHOWN ON NEW WORK
PLAN E102. CLEAN AND RELAMP FIXTURES PRIOR TO REINSTALLING.
26.2 3 REMOVE EXISTING SCONCE. REUSE EXISTING CONDUIT, WIRING, AND CONTROLS
FOR REPLACEMENT.
26.2 4 REMOVE EXISTING BALCONY LIGHT. REUSE EXISTING CONDUIT, WIRING, AND
CONTROLS FOR REPLACEMENT SCONCE. TURN OVER EXISTING FIXTURE TO
OWNER.
26.34 DISCONNECT PUSHBUTTON MOTORIZED DOOR AND RELOCATE AS SHOW ON
NEW WORK PLAN E102
SCALE: 3/32" = 1'-0"6A 1ST FLOOR LIGHTING PLAN DEMO
05/14/2019
10605 N WOLFE RD, CUPERTINO, CA 95014
COURTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
REF.DWJ
CR CR
CRCRCRJ
J JCRJ
J
J
E.201 5A
E.201
6B
E.2024A
E.202
6C
Z102
Z102
Z102
Z102
Z102
Z102
Z102
Z102 Z102
Z102
Z102
Z102
Z102
Z102
Z102
Z102
BG
BG
BG
BG
BG
BG
BG
BG
BG
BG
BG
BG
BG
BG
BG
BG
BG
BG
BG
BG
BG
BG
BG
BG BG
BG BG BG BG BG
BG
BG
BG
BGBGBG
26.12
TYPICAL
26.12
TYPICAL
TYPICAL
TYPICAL
TYPICAL
26.20
26.20
26.20
26.20
TYPICAL
26.20
26.17
26.17
26.17
TYPICAL
TYPICAL
26.16
26.11
26.10
TYPICAL
26.14
26.15
26.11
26.11
E.102
3E
BG
BG
BG
BG
BG
BG
26.9
26.35
26.35
26.35
26.17
26.37
26.37
26.38
26.37
TYPICAL
W1
W1
W1
W1
W1
W1
W1
W1
W1
W1
W1 W1 W1
W1 W1
W1 W1 W1
W1 W1
W1
W1
W1W1 W1
W1 W1
W1
W1 W1 W1
Z102
Z102
Z102
26.17
26.17
Z102
Z102
26.17
W1
W1
Z102
26.17
Z102
26.17
BG
26.44
BG
26.44
BG
26.44
BG
26.44
BG
26.44
BG
26.44
C
C
C
C
C
C
26.9
26.8
26.7
26.21
26.17
Z102
Z102
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 11/12/2019 10:34:55 AM C:\Users\slebow\Documents\Revit Files\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Electrical_Exterior_R18_slebow.rvt
GROUND FLOOR - NEW
WORK
05/14/2019 -
PERMIT SET
E.102
2.180648.0
106050 N. WOLF RD,
CUPERTINO CA 95014
COU RTYARD BY
MARRIOT - SAN
JOSE CUPERTINO,
CA
SCALE: 3/32" = 1'-0"6A 1ST FLOOR LIGHTING PLAN
SCALE: 1/8" =1'-0"DRAWING REF:E.1023E1STFLOORLIGHTINGPLAN - FRONT STAIR CASE
C 1 1 /20/2 01 9 BUILDING PERMIT REVIEW -
REVISION #3
PR
PR
PR
PR
PR
KEYNOTES
2 6.1 6 PROVIDE CONNECTION TO SIGNAGE BACKLIGHTING. COORDINATE ALL FINAL
CONNECTIONS WITH EQUIPMENT SUPPLIED.
26.17 PROVIDE 4" SQUARE FIXTURE, EATON LIGHTING AS INDICATED.
26.20 PROVIDE ONE FOR ONE REPLACEMENT OF EXISTING FIXTURE WITH NEW
FIXTURE AS SHOWN. REUSE EXISTING CIRCUIT AND CONTROLS. BOLLARD
ORIENTATION SHALL BE TOWARDS NEAREST PATHWAY.
26.21 CIRCUIT NEW PUSHBUTTON MOTORIZED DOOR TO SPARE 20A BREAKER IN
EXISTING PANEL IN CLOSEST CLOSET ; FIELD VERIFY LOCATION. SEE
ARCHITECTURE DRAWINGS FOR PUSHBUTTON MOUNTING HEIGHTS AND
LOCATIONS.
26.35 RECONNECT PUSHBUTTON MOTORIZED DOOR TO EXISTING CIRCUIT SERVING
THIS AREA. FIELD VERIFY EXACT LOCATION
26.37 RECONNECT TO EXISTING CIRCUIT AND CONTROLS SERVING THIS AREA.
26.38 CONNECT TO 20A 120V EXISTING CIRCUIT SERVING AREA ON SECOND FLOOR
FOR SIGNAGE. FIELD VERIFY EXACT LOCATION.
26.44 PROVIDE NEW FIXTURE AS SHOWN. REUSE NEAREST EXISTING BOLLARD CIRCUIT
AND CONTROLS. BOLLARD ORIENTATION SHALL BE TOWARDS NEAREST
PATHWAY. FIELD VERIFY LOAD DOES NOT EXCEED EXISTING BREAKER
RATING.UK
KEYNOTES
26.7 CIRCUIT NEW EXTERIOR EGRESS LIGHTING TO SPARE 20A BREAKER IN EXISTING
PANEL IN CLOSEST CLOSET; FIELD VERIFY LOCATION. PROVIDE EXTERIOR
LIGHTING CONTROLS TO MATCH EXISTING.
26.8 REINSTALL EXISTING CARD READER. EXTEND ALL WIRING AND CONTROLS TO
NEW LOCATION. SEE ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS AND
LOCATION.
26.9 PROVIDE ONE FOR ONE REPLACEMENT OF EXISTING FIXTURE WITH NEW.
TYPICAL ALL FLOORS. REUSE EXISTING CIRCUIT AND CONTROLS.
26.10 REINSTALL EXISTING LIGHTS. EXTEND EXISTING CIRCUIT AND WIRING TO NEW
LOCATIONS. REUSE EXISTING CIRCUIT AND CONTROLS.
26.11 NEW STRIP LIGHTING UNDER ROOF. SEE ELEVATIONS ON E201, E202, AND
ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION.
26.12 PROVIDE ONE FOR ONE REPLACEMENT OF EXISTING FIXTURE WITH NEW
FIXTURE AS SHOWN. TYPICAL ALL FLOORS. REUSE EXISTING CIRCUIT AND
CONTROLS. REPLACE FIXTURES ON BOTH COURTYARD BALCONIES AND
BUILDING PERIMETER BALCONIES.
26.14 EXTEND ORIGINAL LIGHTING CIRCUIT AND CONTROLS AND RECONNECT TO NEW
FIXTURES.
26.15 CIRCUIT IN SPARE IN PANEL LOCATED IN CLOSEST CLOSET; FIELD VERIFY. TIE
INTO EXISTING EXTERIOR LIGHTING CONTROL SYSTEM. C
1 1 /22/201 9
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
26.43
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 11/12/2019 10:35:00 AM C:\Users\slebow\Documents\Revit Files\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Electrical_Exterior_R18_slebow.rvt
GROUND FLOOR - SITE
PHOTOMETRICS
05/14/2019 -
PERMIT SET
E.103
2.180648.0
106050 N. WOLF RD,
CUPERTINO CA 95014
COU RTYARD BY
MARRIOT - SAN
JOSE CUPERTINO,
CA
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
C 1 1 /20/2 01 9 BUILDING PERMIT REVIEW -
REVISION #3
SCALE:1/16" =1'-0"6A GROUND FLOOR - SITE PHOTOMETRICS
KEYNOTES
26.43 EXISTING POLE FIXTURES CALCULATED USING EQUIVALENT MODERN POLE
FIXTURE OF SAME MANUFACTURER. LOCATION AND MODEL BASED ON EXISTING
DRAWINGS. CONTRACTOR TO FIELD VERIFY LIGHTING REQUIREMENTS.
1 1 /22/201 9
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
SITE BOUNDARY LINE
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 2/12/2020 1:53:54 PM C:\Users\slebow\Documents\Revit Files\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Electrical_Exterior_R18_slebow.rvt
GROUND FLOOR - SITE
BOUNDARY
PHOTOMETRICS
05/14/2019 -
PERMIT SET
E.104
2.180648.0
106050 N. WOLFE RD,
CUPERTINO CA 95014
COU RTYARD BY
MARRIOT - SAN
JOSE CUPERTINO,
CA
D 02/1 4/2 01 9 BUILDING PERMIT REVIEW -
REVISION #4
SCALE:1/16" =1'-0"6A GROUND FLOOR - SITE BOUNDARY PHOTOMETRICS
GENERAL NOTES
1. SITE BOUNDARY PHOTOMETRIC CALCULATION PERFORMED ONLY WITH NEW
LIGHTING FIXTURES. EXISTING FIXTURES ARE NOT INCLUDED IN SITE
BOUNDARY PHOTOMETRIC CALCULATION.
D
02/12/2020
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
26.13
26.13
26.13
26.38
26.16
26.13
26.12
TYPICAL
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 1:11:48 PM C:\Users\skruyne\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Electrical_Exterior_R18_skruyne.rvt
ELEVATIONS
05/14/2019 -
PERMIT SET
E.201
2.180648.0
KEYNOTES
26.1 2 PROVIDE ONE FOR ONE REPLACEMENT OF EXISTING FIXTURE WITH NEW
FIXTURE AS SHOWN. TYPICAL ALL FLOORS. REUSE EXISTING CIRCUIT AND
CONTROLS. REPLACE FIXTURES ON BOTH COURTYARD BALCONIES AND
BUILDING PERIMETER BALCONIES.
26.1 3 PROVIDE EXTERIOR LED STRIP LIGHTING ALONG NEW WALL, EATON - NEORAY -
"S122-DRL030XXX-0035-1-U-ED-4-B", LENGTH AT REQUIRED, RECESSED GYP
WITH FLANGE. CONNECT TO AVAILABLE CIRCUIT AND PANEL AND EXISTING
EXTERIOR LIGHTING CONTROLS IN ELECTRICAL CLOSEST; CONTRACTOR FIELD
VERIFY.
26.16 PROVIDE CONNECTION TO SIGNAGE BACKLIGHTING. COORDINATE ALL FINAL
CONNECTIONS WITH EQUIPMENT SUPPLIED.
26.38 CONNECT TO 20A 120V EXISTING CIRCUIT SERVING AREA ON SECOND FLOOR
FOR SIGNAGE. FIELD VERIFY EXACT LOCATION.
SCALE:3/32" = 1'-0"DRAWING REF: E.1025AELEVATION -WEST
SCALE:3/32" = 1'-0"DRAWING REF: E.1026BELEVATION -SOUTH
05/14/2019
10605 N WOLFE RD, CUPERTINO, CA 95014
COURTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
26.13
26.12
TYPICAL
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 1:11:59 PM C:\Users\skruyne\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Electrical_Exterior_R18_skruyne.rvt
ELEVATIONS
05/14/2019 -
PERMIT SET
E.202
2.180648.0
SCALE:3/32" = 1'-0"DRAWING REF: E.1024AELEVATION -EAST
SCALE:3/32" = 1'-0"DRAWING REF: E.1026CELEVATION -NORTH
KEYNOTES
26.1 2 PROVIDE ONE FOR ONE REPLACEMENT OF EXISTING FIXTURE WITH NEW
FIXTURE AS SHOWN. TYPICAL ALL FLOORS. REUSE EXISTING CIRCUIT AND
CONTROLS. REPLACE FIXTURES ON BOTH COURTYARD BALCONIES AND
BUILDING PERIMETER BALCONIES.
26.1 3 PROVIDE EXTERIOR LED STRIP LIGHTING ALONG NEW WALL, EATON -
NEORAY - "S122-DRL030XXX-0035-1-U-ED-4-B", LENGTH AT REQUIRED,
RECESSED GYP WITH FLANGE. CONNECT TO AVAILABLE CIRCUIT AND
PANEL AND EXISTING EXTERIOR LIGHTING CONTROLS IN ELECTRICAL
CLOSEST; CONTRACTOR FIELD VERIFY.
05/14/2019
10605 N WOLFE RD, CUPERTINO, CA 95014
COURTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
ST-1
FC-1
EF-4
EF-3
EF-2
EF-1
NOT FOR
CONSTRUCTION
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 7/2/2019 5:54:44 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
3D VIEWS
05/14/2019 -
PERMIT SET
G.001
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:6A EXTERIOR PERSPECTIVE - FRONT
EXTERIOR COLOR FINISH LEGEND
A
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
07/16/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
ST-1
FC-1
EF-4
EF-3
EF-2
EF-1
NOT FOR
CONSTRUCTION
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 7/2/2019 5:54:56 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
3D VIEWS
05/14/2019 -
PERMIT SET
G.002
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
SCALE:6A EXTERIOR PERSPECTIVE - REAR
EXTERIO R COLOR FINISH LEGEND
A
A
A
A 07/03/2 01 9 PRELIMINARY REVIEW -
REVISION
07/16/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 3/21/2019 10:57:57 AM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
EXISTING CONDITIONS
& DEMOLITION PLAN
05/14/2019 -
PERMIT SET
L.001
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COURTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
B 09/05/2019 PRELIMINARY REVIEW-
REVISION #02
C 11/20/2019 BUILDING PERMIT REVIEW-
REVISION #3
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 3/21/2019 10:57:57 AM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
PLANTING PLAN
L.002
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COURTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
05/14/2019 -
PERMIT SET
B 09/05/2019 PRELIMINARY REVIEW-
REVISION #02
C 11/20/2019 BUILDING PERMIT REVIEW-
REVISION #3
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 3/21/2019 10:57:57 AM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
LANDSCAPE DETAILS,
NOTES, & SCHEDULE
L.003
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COURTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
05/14/2019 -
PERMIT SET
B 09/05/2019 PRELIMINARY REVIEW-
REVISION #02
C 11/20/2019 BUILDING PERMIT REVIEW-
REVISION #3
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 3/21/2019 10:57:57 AM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt
PLANT IMAGE BOARD
(EX. & PROPOSED)
L.004
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COURTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
05/14/2019 -
PERMIT SET
B 09/05/2019 PRELIMINARY REVIEW-
REVISION #02
C 11/20/2019 BUILDING PERMIT REVIEW-
REVISION #3
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
ABBREVIATIONS - PLUMBING
CO CLEANOUT
(E) EXISTING
OST OVERFLOW STORM
ST STORM PIPING
ELBOW, TURNING DOWN
ELBOW, TURNING UP
PIPE CAP
POINT OF CONNECTION, NEW TO EXISTING
REMOVE TO THIS POINT
NEW PIPING OR EQUIPMENT (SHOWN DARK)
EXISTING PIPING OR EQUIPMENT TO REMAIN (SHOWN LIGHT)
EXISTING PIPING OR EQUIPMENT TO BE REMOVED
PLUMBING LEGEND
RD-3A
666 SF
(E) 6" ST
CO AT BASE
(E) 6" ST
RD-3B
666 SF
CAP PIPE CAP
PIPE
CO AT BASE
EXISTING STORM
BELOW GRADE
EXISTING STORM
BELOW GRADE
RD-3A
694 SF
RD-3A,
502 SF
RD-3A,
436 SF
RD-3A,
436 SF
22.19
22.19
RD-3B
694 SF
RD-3B
502 SF
RD-3B,
436 SF
RD-3B,
436 SF
22.20
22.20
22.20
22.20
CAP PIPE
3" ST
3" ST
CO AT BASE
CO AT BASE
3" ST
22.19
TIE INTO EXISTING STORM PIPING.
PROVIDE CLEANOUT AT BASE OF PIPING IN WALL.
TIE INTO EXISTING STORM PIPING.
PROVIDE CLEANOUT AT BASE OF PIPING IN WALL.
POCHE LEGEND
NOT IN CONTRACT
DEMO WORK
APPLICABLE CODES:
BUILDING CODE: 2016 CALIFORNIA BUILDING CODE, VOLUME 1 & 2
PLUMBING CODE: 2016 CALIFORNIA PLUMBING CODE
2016 CALIFORNIA GREEN BUILDING STANDARD CODE
CUPERTINO MUNICIPAL CODE
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 9:19:44 AM C:\Users\rshearon\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Plumbing_R18_rshearon.rvt
NEW WORK ROOF PLAN
05/14/2019 -
PERMIT SET
P.114
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
STORM & STORM OVERFLOW PIPING
(ABOVE SLAB/GRADE)
ST & OST
CAST IRON HUBLESS PIPE, TYPE DWV, ASTM A74, ASTM A888, CISPI 301 WITH MATCHING FITTINGS. JOINT
SURFACES SHALL BE CLEAN AND FREE FROM MOISTURE. HEAVY DUTY SHIELDED COUPLINGS MEETING CISPI 310,
WITH STAINLESS STEEL SHIELD AND NEOPRENE GASKET.
STORM & STORM OVERFLOW PIPING
(BELOW SLAB/GRADE)
ST
PVC, TYPE DWV, ASTM D 2665, WITH MATCHING FITTINGS. JOINT SURFACES SHALL BE CLEAN AND FREE FROM
MOISTURE. A PURPLE PRIMER THAT COMFORMS WITH ASTM F 656 SHALL BE APPLIED. SOLVENT CEMENT NOT
PURPLE IN COLOR AND CONFORMING TO ASTM D 2564 SHALL BE APPLIED TO ALL JOINT SURFACES. THE JOINT
SHALL BE MADE WHILE CEMENT IS WET AND SHALL BE IN ACCORDANCE WITH ASTM D 2588.
SYSTEM SYMBOL PIPE, FITTING AND JOINTS
PLUMBING MATERIAL SCHEDULE
PLUMBING ROOF DRAIN SCHEDULE
TYPE
BODY
MATERIAL
COMBINATION
FLASHING RING AND
GRAVEL STOP DOME MATERIAL
UNDERDECK
CLAMP SUMP RECEIVER WATER DAM REMARKS
RD-3A CAST IRON REQUIRED CAST IRON REQUIRED REQUIRED NOT REQUIRED JAY R SMITH SERIES 1010-R-C-CID
RD-3B CAST IRON REQUIRED CAST IRON REQUIRED NOT REQUIRED REQUIRED JAY R SMITH SERIES 1080-WD025-C-CID
SCALE:3/32" =1'-0"6A NEW WORK ROOF PLAN
KEYNOTES
22.1 9 4"X3" DOWNSPOUT BOOT AT ARCHITECTURAL
DOWNSPOUT. TIE INTO EXISTING STORM PIPING BELOW
GRADE. DOWNSPOUT BOOT TO BE JAY R. SMITH MFG. CO.
NO. 1785. EXTEND NEW STORM PIPING TO EXISTING
UNDERGROUND STORM.
22.2 0 DOWNSPOUT NOZZLE, ZURN NO. Z199.
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda
(E) 6" ST
(E) 6" ST
EXISTING STORM
BELOW GRADE
EXISTING STORM
BELOW GRADE
22.12
22.12
22.12
22.12
POCHE LEGEND
NOT IN CONTRACT
DEMO WORK
COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
ISSUE
PROJECT NUMBER
1 A 2 3 4 5 6 A B C D E13 4 5 6 2 B C D EBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.2 5/14/2019 9:19:47 AM C:\Users\rshearon\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Plumbing_R18_rshearon.rvt
DEMOLITION ROOF PLAN
05/14/2019 -
PERMIT SET
PD.114
2.180648.0
10605 N WOLFE RD, CUPERTINO, CA 95014
COU RTYARD BY
MARRIOTT - SAN
JOSE CUPERTINO,
CA
KEYNOTES
22.12 REMOVE DOWNSPOUT.
SCALE:3/32" = 1'-0"6A DEMOLITION ROOF PLAN
05/14/2019
ASA-2019-007,
TR-2019-034
05/19/20
Erika Poveda