Loading...
HomeMy WebLinkAboutAH Packet 05-14-2020CITY OF CUPERTINO ADMINISTRATIVE HEARING AGENDA This is a teleconference meeting with no physical location Thursday, May 14, 2020 5:00 PM Teleconference Meeting TELECONFERENCE / PUBLIC PARTICIPATION INFORMATION TO HELP STOP THE SPREAD OF COVID-19 In accordance with Governor Newsom’s Executive Order No-29-20, this will be a teleconference meeting without a physical location to help stop the spread of COVID-19. Members of the public wishing comment on an item on the agenda may do so in the following ways: 1) E-mail comments by 4:00 p.m. on Thursday, April 14 to the Hearing Officer at planning@cupertino.org. These e-mail comments will be received by the Hearing Officer before the meeting and posted to the City’s website after the meeting. 2) E-mail comments during the times for public comment during the meeting to the Hearing Officer at planning@cupertino.org. The staff liaison will read the emails into the record, and display any attachments on the screen, for up to 3 minutes (subject to the Hearing Officer’s discretion to shorten time for public comments). Members of the public that wish to share a document must email planning@cupertino.org prior to speaking. 3) Teleconferencing Instructions Members of the public may observe the teleconference meeting or provide oral public comments as follows: Oral public comments will be accepted during the teleconference meeting. Comments may be made during “oral communications” for matters not on the agenda, and during the public comment period for each agenda item . To address the Hearing Officer, click on the link below to register in advance and access the meeting: Online Page 1 Administrative Hearing Agenda May 14, 2020 Please click the link below to join the webinar : https://cityofcupertino.zoom.us/webinar/register/WN_py9Ztnf9RpuM-M0qG7XuaA Phone Dial 888 788 0099 and enter Webinar ID: 959 7759 6491 (Type * 9 to raise hand to speak) Unregistered participants will be called on by the last four digits of their phone number . Or an H.323/SIP room system: H.323: 162.255.37.11 (US West) 162.255.36.11 (US East) Meeting ID: 959 7759 6491 SIP: 95977596491@zoomcrc.com After registering, you will receive a confirmation email containing information about joining the webinar. Please read the following instructions carefully: 1. You can directly download the teleconference software or connect to the meeting in your internet browser. If you are using your browser, make sure you are using a current and up-to-date browser: Chrome 30+, Firefox 27+, Microsoft Edge 12+, Safari 7+. Certain functionality may be disabled in older browsers, including Internet Explorer . 2. You will be asked to enter an email address and a name, followed by an email with instructions on how to connect to the meeting. Your email address will not be disclosed to the public. If you wish to make an oral public comment but do not wish to provide your name, you may enter “Cupertino Resident” or similar designation. 3. When the Hearing Officer calls for the item on which you wish to speak, click on “raise hand.” Speakers will be notified shortly before they are called to speak. 4. When called, please limit your remarks to the time allotted and the specific agenda topic . In compliance with the Americans with Disabilities Act (ADA), anyone who is planning to attend this teleconference meeting who is visually or hearing impaired or has any disability that needs special assistance should call the City Clerk's Office at 408-777-3223, at least 48 hours in advance of the meeting to arrange for assistance. In addition, upon request, in advance, by a person with a disability, meeting agendas and writings distributed for the meeting that are public records will be made available in the appropriate alternative format. Page 2 Administrative Hearing Agenda May 14, 2020 ROLL CALL APPROVAL OF MINUTES 1.Subject: Draft Minutes of January 9, 2020 Recommended Action: Approve or modify the Draft Minutes of January 9, 2020 Draft Minutes of January 9, 2020 ORAL COMMUNICATIONS This portion of the meeting is reserved for persons wishing to address the Hearing Officer on any matter within the jurisdiction of the Hearing Officer and not on the agenda. Speakers are limited to up to three (3) minutes. In most cases, State law will prohibit the Hearing Officer from making any decisions with respect to a matter not on the agenda. PUBLIC MEETING 2.Subject: Architectural and Site Approval Permit to allow for facade and landscape modifications to an existing hotel (Courtyard by Marriott); and a Tree Removal Permit to allow the removal and replacement of 15 development trees. Application No(s): ASA-2019-007, TR-2019-034; Applicant(s): Tom Young (Spectrum Development); Location: 10605 N Wolfe Rd APN #316-47-019 Recommended Action: That the Hearing Officer adopt the draft resolutions to: 1) Find that the proposed actions are exempt from CEQA; and 2) Approve the Architectural and Site Approval Permit (ASA-2019-007) and the Tree Removal Permit (TR-2019-034). Administrative Hearing Officer's decision final unless appealed Staff Report 1 - Draft Resolution for ASA-2019-007 2 - Draft Resolution for TR-2019-034 3 - Plan Set 4 - Arborist Report PUBLIC HEARINGS OLD BUSINESS NEW BUSINESS ADJOURNMENT In compliance with the Americans with Disabilities Act (ADA), anyone who is planning to attend this teleconference meeting who is visually or hearing impaired or has any disability that needs special assistance should call the City Clerk's Office at 408-777-3223, at least 48 hours in advance of the meeting to arrange for assistance. In addition, upon request, in advance, by a person with a disability, Page 3 Administrative Hearing Agenda May 14, 2020 meeting agendas and writings distributed for the meeting that are public records will be made available in the appropriate alternative format. Any writings or documents provided to a majority of the members after publication of the agenda will be made available for public inspection. Please contact the City Clerk’s Office in City Hall located at 10300 Torre Avenue during normal business hours. IMPORTANT NOTICE: Please be advised that pursuant to Cupertino Municipal Code 2.08.100 written communications sent to the Cupertino City Council, Commissioners or City staff concerning a matter on the agenda are included as supplemental material to the agendized item. These written communications are accessible to the public through the City’s website and kept in packet archives. You are hereby admonished not to include any personal or private information in written communications to the City that you do not wish to make public; doing so shall constitute a waiver of any privacy rights you may have on the information provided to the City . Members of the public are entitled to address the members concerning any item that is described in the notice or agenda for this meeting, before or during consideration of that item. If you wish to address the members on any other item not on the agenda, you may do so during the public comment . Page 4 Cupertino, CA 95014 (408) 777-3308 ACTION MINUTES OF THE REGULAR MEETING OF THE ADMINISTRATIVE HEARING HELD ON January 9, 2020 ROLL CALL Hearing Officer present: Albert Salvador, Assistant Director of Community Development Staff present: Ellen Yau, Associate Planner Applicant(s) present: Nathan Ung, 19900 Stevens Creek Blvd, LLC Scott Stotler, Dutchins Development, LLC APPROVAL OF MINUTES: 1. August 22, 2019 The minutes of August 22, 2019 were approved as written POSTPONEMENTS/REMOVAL FROM CALENDAR: None ORAL COMMUNICATIONS: None WRITTEN COMMUNICATIONS: None PUBLIC MEETING ITEMS: 2. Application No.(s): DP-2019-001, ASA-2019-006, TR-2019-032 Applicant: Nathan Ng (19900 Stevens Creek Blvd, LLC) Location: 19900 Stevens Creek Blvd APN# 369-05-038 Development Permit to allow the construction of 2,235 square feet of new commercial use space to an existing retail building (Scandinavian Design); an Architectural and Site Approval to allow facade, parking, landscaping and site improvements; and a Tree Removal Permit to allow the removal and replacement of twenty-five (25) development trees. Administrative Hearing Officer’s decision final unless appealed. Staff member Yau addressed the Hearing Officer. She explained that the property owners are proposing to remodel the former Scandinavian Design furniture store. They will be enclosing two walkways, making façade changes, creating an interior courtyard, and re-designing the building to allow for multiple tenant spaces. They have worked with Staff to meet the landscape easement requirements for the Heart of the City Plan. There will be 114 parking 2 Administrative Hearing January 9, 2020 spaces where 112 are required. There will also be a bicycle parking area. The applicants are voluntarily participating in the City’s Public Art program by having a mural painted on the northwestern corner of the building. Other City Department Staff have reviewed the proposed project and have no concerns. The applicant, Nathan Ung, addressed the Hearing Officer. He feels that due to the location of the building, large store retail is not the best use for this space. The traffic flow is not convenient for customers as there is no left-hand turn entrance. The smaller retail, service based (insurance sales, real estate agency, etc.) shops are a better fit for this site. These types of business are quiet and usually do not have a lot of customers in at one time. The architectural upgrades and other site improvements should make the building much more inviting for future tenants. The Hearing Officer opened the public comment period. Alan Roth King Wah and Wei Wei The Hearing Officer closed the comment period. The Hearing Officer asked for clarification that the proposed project meets the parking requirements and that the proposed service retail uses are permitted for the site. Staff member Yau confirmed. He asked if the existing landscaping was going to be removed to accommodate the parking. She said that a small area was going to be removed, but it was far away from the frontage so was not in conflict with the Heart of the City landscaping requirements. The Hearing officer asked about the number of accessible and EV parking spaces. The applicant stated that they are in compliance with the number of accessible spaces required and have planned to add two EV spaces in the future. He also stated that tenants coming into the site will not be grocery , entertainment or restaurant as the site does not meet the parking requirements for those types of uses. A new trash enclosure will be installed on site. The Hearing officer concurred with Staff’s findings. Since the building envelope was not changing, the uses of the site are in conformance and the overall design will be an improvement, the application was approved. He informed the applicant that if the uses of the building were to change to conditional uses in the future, a new hearing would be required. DECISION: The applications were approved by the Hearing Officer per the draft resolution(s). 3. Application No.(s): ASA-2019-005 Applicant: Scott Stotler (Dutchints Development, LLC) Location: 10100 Bubb Rd APN# 357-20-024 Architectural and Site Approval Permit to allow for architectural an d site improvements to an existing 13,250 square foot industrial building. Administrative Hearing Officer’s decision final unless appealed. Staff member Yau addressed the Hearing Officer. She explained that the property most recently has been used for a repair shop. The current owner would like to use the space for a real estate development firm. The site is located in a Light Industrial Zone, so this is a 3 Administrative Hearing January 9, 2020 permitted use. The application will slightly reduce the building shell by approximately 400 square feet to create a courtyard entrance. The building will undergo architectural changes that will reduce the look of the mass and scale through a new roof design and glass storefront elements where entrances used to be. A new sidewalk will be installed along the front and the parking lot will be re-striped to provide 47 spaces. None of the trees on site will be removed as part of these upgrades. A variety of new trees and shrubs will be planted as is required by the City’s Municipal Code. The proposed project has been reviewed by other City departments. They had no concerns about the proposed changes to the site. The applicant, Scott Stotler, said he was available to answer any questions. His team has worked with Staff to create a new façade to this building that he hopes will inspire the adjacent property owners and other others in the area to want to make changes to their spaces too. The Hearing Officer clarified that the space will just have one tenant in it. The applicant said that they have no plans to subdivide the space to house multiple tenants. The Hearing Officer reminded the applicant about the requirements for accessible parking spaces and asked for clarification regarding the ‘path of travel’ from the parking lot to the building entrances. The Hearing Officer said the applicant will need to work on these issues with the Building Department during the building permit issuance process. The Hearing Officer opened the public comment period. There were no speakers. The Hearing Officer closed the comment period. The Hearing Officer reviewed the presentation from Staff and the Applicants. He concurred that the project is in conformance with the City’s Municipal Code and that the proposed building upgrades will not be detrimental to the surrounding businesses. DECISION: The applications were approved by the Hearing Officer per the draft resolution(s). ADJOURNMENT Respectfully submitted: _____/s/Beth Ebben Beth Ebben Deputy Board Clerk ADMINISTRATIVE HEARING STAFF REPORT Meeting Date: May 14, 2020 Subject Architectural and Site Approval Permit to allow for façade and landscape modifications to the Courtyard by Marriott Hotel. Tree Removal Permit to allow for the removal and replacement of 15 development trees. (Application No(s).: ASA-2019-007, TR-2019-034; Applicant: Tom Young (Spectrum Development); Location: 10605 N. Wolfe Road.; APN(s): 316-47-049) Recommended Action That the Hearing Officer adopt the draft resolutions (Attachments 1 and 2) to: 1. Find that the proposed actions are exempt from CEQA; and 2. Approve the Architectural and Site Approval Permit (ASA-2019-007) and the Tree Removal Permit (TR-2019-034). Discussion Project Data General Plan Designation Commercial/Residential General Plan Special Area North Vallco Special Area Zoning Designation P(Hotel) Lot Size 154,624 sq. ft. (3.55 Acres) Existing Proposed Floor Area 79,406 sq. ft. (51.4%) No Change Lot Coverage 35,223 sq. ft. (22.8%) 35,911 sq. ft. (23.2%) Building Height 47’-6” No change Project Consistency With: General Plan Yes Zoning Yes Environmental Assessment Categorically Exempt per Section 15301 (Class 1) of the California Environmental Quality Act (CEQA) ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020 Page 2 Background The property is located within the North Vallco Gateway in the North Vallco Special Area. The North Vallco Special Area is a major employment center for Cupertino and is primarily comprised of commercial and office development – including Courtyard by Marriott, Hilton Garden, Cupertino Village, and Apple Campus 2. The project site is bounded by Homestead Road to the north, N. Wolfe Road to the east, HWY-280 to the south, and Linnet Lane the west (see Figure 1). The property is located adjacent to the Hilton Garden Inn and an approved (not constructed yet) 185-room hotel to the north, multi-family residential (Arioso Apartments & The Hamptons) to the north west and east and single-family residential to the west (off Linnet Lane). The 149- room Courtyard by Marriott Hotel was approved in 1986 by Planning Commission with the approval of U-1986-33. Analysis The applicant is requesting façade and landscape modifications to the existing Courtyard by Marriott Hotel. The scope of work for the project is as follows:  Replacement of the arrival porte cochere;  Installation of architectural elements at the main and side entrances;  Exterior façade architectural material upgrades;  Demolition and replacement of the trash enclosure;  Installation of a new bicycle parking rack;  Removal and replacement of 15 development trees; and  Landscape enhancements. Figure 1. Project site N. WOLFE ROAD LINNET LANE HILTON GARDEN INN ARIOSO APARTMENTS ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020 Page 3 The scope of work does not include any increase to the existing room count, floor area, or height and will therefore not result in an increased intensity of the existing use. Exterior Building Modifications The existing exterior materials for the Courtyard by Marriott consist of stucco walls with a tile roof in a neutral color palette (see Figure 2). In line with Courtyard’s new contemporary aesthetic, the applicant is requesting to modernize the building by incorporating additional textures and finishes, including dry stone, faux wood (fiber cement) wall paneling, and metal elements, along with a more contemporary color scheme of white, greys, and brown. As part of this project, the arrival porte cochere, main entrance and two entry stair towers (on the east and west elevations) will be replaced with a more modern design feature with a contemporary flat-roof, faux wood paneling, and metal accents (see Figures 3 & 4). The porte cochere will be reduced in height by ~5.5’ (from 18’-4” to 12’10”) and the main entrance by one foot (from 23’-10” to 22’10”). The proposed porte cochere will be slightly larger in size and will cause the lot coverage to marginally increase from 35,223 sq. ft. (22.8%) to 35,911 sq. ft. (23.2%). The North Vallco Special Area does not have a lot coverage limitation imposed on the site. In order to achieve the desired aesthetic, the applicant has proposed a minor increase in the parapet height for the east and west entry stair towers, resulting in a total increase in height of ~one-foot (from 32’-3” to ~33’-4”). However, the overall height of the building Figure 2. Existing Conditions ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020 Page 4 is not impacted since the existing roof forms of the bulk of the structure will remain unchanged. The proposed design was peer-reviewed by the City’s consulting architect who found that the proposed changes are minor in scope and are architecturally harmonious with the other portions of the building. Figure 3 (above). Existing and Proposed North Elevation Figure 4 (below). Existing and Proposed West Elevation ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020 Page 5 The existing floor area and the number of guestrooms will not be impacted by the proposed scope of work. New lighting fixtures are also proposed as part of the scope of work. The applicant has provided site photometrics, which indicate that the new light fixtures will not cause light to spill-over onto adjacent residential or hotel properties. Modifications to the existing signage are not part of th is scope of work and have been reviewed and approved with a separate Building Permit (BLD-2020-0234). Tree Removals/Replacements & Landscape Modifications Per the Protected Trees Ordinance (Chapter 14.18) of the Cupertino Municipal Code (CMC), all approved development trees (i.e. trees required to be planted or retained as part of a development application, building permit, tree removal permit, or code enforcement action) are considered “protected” and require approval of a tree removal permit prior to removal. Replacements for the removed trees are required as part of the tree removal permit. The applicant is proposing to remove a total of 15 development trees along the exterior of the building as part of the Tree Removal Permit (TR-2019-034). The arborist report (Attachment 4) assesses the location, size, current condition, and overall health of the trees proposed to be removed. These trees have generally been identified to be in good condition, with trees #2 and #7 in fair condition, and trees #15 and #16 in critical condition. Per the draft conditions of approval for TR-2010-034, all trees outlined in the arborist report for removal are approved, with the exception of Tree #3, which shall remain on site. The table below includes the trees proposed for removal (note: tree # corresponds with the tree inventory provided with the arborist report). TABLE 1 – TREES TO BE REMOVED AND REPLACEMENTS Tree # DBH Tree Species Replacements 1 15 Camphor (Cinnamomum camphora) 2 – 24” box 2 6 Camphor (Cinnamomum camphora) 1 – 24” box 4 15 Southern Live Oak (Quercus virginiana) 2 – 24” box 5 15 Southern Live Oak (Quercus virginiana) 2 – 24” box 6 14 Southern Live Oak (Quercus virginiana) 2 – 24” box 7 14 Southern Live Oak (Quercus virginiana) 2 – 24” box 8 8 Japanese black pine (Pinus thunbergiana) 1 – 24” box 9 14 Australian Willow (Geijera parviflora) 2 – 24” box 10 12 Southern Live Oak (Quercus virginiana) 1 – 24” box 11 12 Southern Live Oak (Quercus virginiana) 1 – 24” box ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020 Page 6 TABLE 1 – TREES TO BE REMOVED AND REPLACEMENTS Tree # DBH Tree Species Replacements 12 12 Southern Live Oak (Quercus virginiana) 1 – 24” box 13 2 Eastern Redbud (Cercis canadensis) 1 – 24” box 14 3 Eastern Redbud (Cercis canadensis) 1 – 24” box 15 10 Coast Redwood (Sequoia sempervirens) 1 – 24” box 16 7 Coast Redwood (Sequoia sempervirens) 1 – 24” box Total Replacements Required 21 – 24” box The required replacement trees per the Protected Trees Ordinance are 21 24”-box trees. The applicant exceeds the minimum number of replacement trees by proposing 27 trees to be planted on site as follows:  12 24”-Box Crape Myrtle (Lagerstroemia Indica)  7 24”-Box Fruitless Olive (Olea Europaea)  6 24”-Box Streetspire Oak (Quercus Robur)  2 24”-Box Coast Redwood (Sequoia sempervirens) These trees will be retained on the site as protected development trees. The arborist report and proposed tree replacement species and locations were peer -reviewed by the City’s Arborist who had no objections to the project. No trees along the westerly property line adjoining the existing residential development are proposed for removal. The applicant is also proposing to modify the existing landscape by removing and replacing portions of the existing turf and planting area. The project is subject to a Full Landscape Documentation Package per the Landscape Ordinance (Chapter 14.15) of the CMC. The Landscape Ordinance requires the applicant to submit a Water -Efficient Landscape Checklist, Water Budget Calculations, and finalized landscape, irrigation, and grading design plan prior to building permit issuance. Additional Site Modifications The applicant is proposing to install a bicycle parking rack near the main entrance of the hotel. The Parking Ordinance (Chapter 19.124) of the CMC requires one Class II bicycle parking stall per every 20,000 sq. ft. of hotel floor area. The proposed bicycle rack complies with the Parking Ordinance by providing 4 Class II bicycle parking stalls for the 79,406 sq. ft. hotel. The proposed plan will maintain the existing 140 vehicular parking stalls required for the site. The applicant is also proposing to replace the existing wood trash enclosure with a new 240 sq. ft. covered trash enclosure with a total height of 9’-9” in compliance with the City’s requirements. The proposed trash enclosure will be located on the west building ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020 Page 7 elevation and will incorporate the same exterior materials and paint color scheme proposed throughout the primary building. The trash enclosure is considered an accessory structure and is consistent with the Accessory Buildings/Structures Ordinance (Chapter 19.100) of the CMC with regard to height and setbacks. As part of the site modifications, the applicant has agreed to remove a portion of the existing 6’ chain link fence along the east property line surrounding the pedestrian and bicycle access pathway off N. Wolfe Road. Interior modifications and minor tenant improvements have been reviewed and approved by a separate Building Permit (B-2019-0205). Environmental Review This project is categorically exempt from the requirements of the California Environmental Quality Act (CEQA) per Section 15301 – Existing Facilities. Other Department/Agency Review The City’s Building Division, Environmental Programs Division, Public Works Department, and the Santa Clara County Fire Department have no objections to the project. Public Noticing & Community Outreach The following table is a brief summary of the noticing for this project: Notice of Public Hearing Agenda  Site Signage (at least 10 days prior to hearing)  7 notices mailed to property owners adjacent to the project site (at least 10 days prior to the hearing)  Posted on the City's official notice bulletin board (five days prior to hearing)  Posted on the City of Cupertino’s Web site (five days prior to hearing) No comments have been received at the time of production of this staff report. Permit Streamlining Act This project is subject to the Permit Streamlining Act (Government Code Section 65920 – 65964). The City has complied with the deadlines found in the Permit Streamlining Act. Project Received: September 26, 2019; Deemed Incomplete: October 29, 2019 Revisions Received: January 5, 2020; Deemed Incomplete: February 5, 2020 Revisions Received: February 25, 2020; Deemed Complete: March 25, 2020 ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020 Page 8 Since this project is Categorically Exempt, the City has 60 days (until May 25, 2020) to make a decision on the project. Conclusion Staff recommends approval of the Architectural and Site Approval Permit and the Tree Removal Permit, as the proposed project will not create adverse impacts to the surrounding area. Additionally, all the findings for approval of the proposed project, consistent with Chapter 19.168 and 14.18 of the Cupertino Municipal Code, may be made as reflected in the draft resolutions. With respect to the Architectural and Site Approval Permit, the following findings may be made: 1. The proposal, at the proposed location, will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience; The proposal includes façade modifications to the existing Courtyard by Marriott hotel that modernize the architectural style of the building. The exterior enhancements will incorporate a flat-roof design, additional textures and finishes, including dry stone, faux wood (fiber cement) wall paneling, and metal elements, and a more contemporary color scheme of white, greys, and brown. The existing floor area, number of guestrooms, and total building height will not be impacted by the proposed scope of work and the footprint of the existing hotel will largely be retained with a minor increase in lot coverage. The materials used will have to comply with building code and other state code standards for health and safety. Furthermore, the project is located at an established hotel site in a residential and commercial district and is surrounded by another hotel use, multi-family residential, and a small number of single-family residential uses. Therefore, the façade modifications will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the publi c health, safety, general welfare, or convenience. 2. The proposal is consistent with the purposes of Chapter 19.168, the General Plan any specific plan, zoning ordinances, applicable planned development permit, conditional use permits, variances, subdivision maps or other entitlements to use which regulate the subject property including, but not limited to, adherence to the following specific criteria: a) Abrupt changes in building scale should be avoided. A gradual transition related to height and bulk should be achieved between new and existing buildings. The scale of the building will be maintained with no increase to the height. The façade modifications will incorporate a flat-roof design at the main entrance, which will result in a minor reduction in bulk. Overall, the hotel will maintain the same form as the existing ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020 Page 9 structure with an enhanced contemporary design. Therefore, there will be no abrupt changes in building scale related to height and bulk and no new buildings are being proposed. b) In order to preserve design harmony between new and existing buildings and in order to preserve and enhance property values, the materials, textures and colors of new building should harmonize with adjacent development by being consistent or compatible with design and color schemes with the future character of the neighborhoods and purposes of the zone in which they are situated. The location, height and materials of walls, fencing, hedges and screen planting should harmonize with adjacent development. Unsightly storage areas, utility installations and unsightly elements of parking lots should be concealed. The planting of ground cover or various types of pavements should be used to prevent dust and erosion, and the unnecessary destruction of existing healthy trees should be avoided. Lighting for development should be adequate to meet safety requirements as specified by the engineering and building departments and provide shielding to prevent spill-over light to adjoining property owners. The façade modifications are harmonious with the existing building form and the proposed upgrades to the existing materials and colors will not impact the future character of the neighborhood. The new trash enclosure is located to the west of the building in an area not visible from the public right-of-way and is designed to be compatible with the proposed aesthetic of the hotel. The proposed tree removals are due to poor initial planting locations that are not suitable for the continued maintenance of the trees. The proposed tree replacements will improve the aesthetics of the site for its users. Additional landscaping is being proposed to enhance existing landscaping at the site. The proposed new lighting fixtures are designed in order to prevent spill-over light to adjoining properties. c) The number, location, color, size, height, lighting and landscaping of outdoor advertising signs and structures have been designed to minimize traffic hazard, positively affect the general appearance of the neighborhood and harmonize with adjacent development. No signs are proposed as part of this project. d) With respect to new projects within existing residential neighborhoods, new development should be designed to protect residents from noise, traffic, light and visually intrusive effects by use of buffering, setbacks, landscaping, walls and other appropriate design measures. This application is not a new development project. ASA-2019-007, TR-2019-034 10605 N. Wolfe Rd. May 14, 2020 Page 10 With respect to the Tree Removal Permit, the following findings may be made: 3. That the protected trees are a detriment to the subject property and cannot be adequately supported according to good urban forestry practices due to the overplanting or overcrowding of trees on the subject property. The proposed tree removals are due to poor initial planting locations that are not suitable for the continued maintenance of the trees. The proposed tree replacements will improve the aesthetics of the site for its users. The City’s consulting arborist has reviewed the arborist report and takes no exception to the proposal for removal. Next Steps The permit will become effective 14 calendar days from the date of the hearing. The decision of the Administrative Hearing Officer is final, unless appealed within 14 calendar days from the date of the hearing. The applicant team may apply for building and/or other permits with the City at the end of the appeal period (May 28, 2020 at 5:00pm). This approval is valid until May 14, 2022. The applicant team may apply for a one-time two-year extension before the approval expires. Prepared by: Erika Poveda, Associate Planner Reviewed and Approved for submission by: Piu Ghosh, Planning Manager ATTACHMENTS 1. Draft Resolution for ASA-2019-007 2. Draft Resolution for TR-2019-034 3. Plan Set 4. Arborist Report ASA-2019-007 CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 DRAFT RESOLUTION OF THE ADMINISTRATIVE HEARING OFFICER OF THE CITY OF CUPERTINO APPROVING AN ARCHITECTURAL AND SITE PERMIT TO ALLOW FAÇADE AND LANDSCAPE MODIFICATIONS TO THE EXISTING COURTYARD BY MARRIOTT HOTEL LOCATED AT 10605 N. WOLFE ROAD SECTION I: PROJECT DESCRIPTION Application No.: ASA-2019-007 Applicant: Tom Young (Spectrum Development) Location: 10605 N. Wolfe Road (APN 316-47-049) SECTION II: FINDINGS WHEREAS, the City of Cupertino received an application for an Architectural and Site Approval to consider allowing modifications to the exterior building materials and landscaping for an existing hotel, as described in Section I. of this Resolution; and WHEREAS, the necessary public notices have been given as required by the Procedural Ordinance of the City of Cupertino, and the Administrative Hearing Officer has held at least one public meeting with regard to the application; and WHEREAS, pursuant to the provisions of the California Environmental Quality Act of 1970 (Public Resources Code section 21000 et seq.) (“CEQA”), together with the State CEQA Guidelines (California Code of Regulations, Title 14, Section 15000 et seq.) (hereinafter, "CEQA Guidelines"), the City staff has independently studied the proposed Project and has determined that the Project is exempt from environmental review pursuant to the categorical exemption in CEQA Guidelines section 15301 for the reasons set forth in the staff report dated May 14, 2020 and incorporated herein; and WHEREAS, the applicant has met the burden of proof required to support said application; and Draft Resolution ASA-2019-007 May 14, 2020 Page 2 WHEREAS, the Administrative Hearing Officer finds as follows with regard to this application: 1. The proposal, at the proposed location, will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience; The proposal includes façade modifications to the existing Courtyard by Marriott hotel that modernize the architectural style of the building. The exterior enhancements will incorporate a flat-roof design, additional textures and finishes, including dry stone, faux wood (fiber cement) wall paneling, and metal elements, and a more contemporary color scheme of white, greys, and brown. The existing floor area, number of guestrooms, and total building height will not be impacted by the proposed scope of work and the footprint of the existing hotel will largely be retained with a minor increase in lot coverage. The materials used will have to comply with building code and other state code standards for health and safety. Furthermore, the project is located at an established hotel site in a residential and commercial district and is surrounded by another hotel use, multi-family residential, and a small number of single-family residential uses. Therefore, the façade modifications will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience. 2. The proposal is consistent with the purposes of Chapter 19.168, the General Plan any specific plan, zoning ordinances, applicable planned development permit, conditional use permits, variances, subdivision maps or other entitlements to use which regulate the subject property including, but not limited to, adherence to the following specific criteria: a) Abrupt changes in building scale should be avoided. A gradual transition related to height and bulk should be achieved between new and existing buildings. The scale of the building will be maintained with no increase to the height. The façade modifications will incorporate a flat-roof design at the main entrance, which will result in a minor reduction in bulk. Overall, the hotel will maintain the same form as the existing structure with an enhanced contemporary design. Therefore, there will be no abrupt changes in building scale related to height and bulk and no new buildings are being proposed. b) In order to preserve design harmony between new and existing buildings and in order to preserve and enhance property values, the materials, textures and colors of new building should harmonize with adjacent development by being consistent or compatible with design and color schemes with the future character of the Draft Resolution ASA-2019-007 May 14, 2020 Page 3 neighborhoods and purposes of the zone in which they are situated. The location, height and materials of walls, fencing, hedges and screen planting should harmonize with adjacent development. Unsightly storage areas, utility installations and unsightly elements of parking lots should be concealed. The planting of ground cover or various types of pavements should be used to prevent dust and erosion, and the unnecessary destruction of existing healthy trees should be avoided. Lighting for development should be adequate to meet safety requirements as specified by the engineering and building departments and provide shielding to prevent spill-over light to adjoining property owners. The façade modifications are harmonious with the existing building form and the proposed upgrades to the existing materials and colors will not impact the future character of the neighborhood. The new trash enclosure is located to the west of the building in an area not visible from the public right-of-way and is designed to be compatible with the proposed aesthetic of the hotel. The proposed tree removals are due to poor initial planting locations that are not suitable for the continued maintenance of the trees. The proposed tree replacements will improve the aesthetics of the site for its users. Additional landscaping is being proposed to enhance existing landscaping at the site. The proposed new lighting fixtures are designed in order to prevent spill-over light to adjoining properties. c) The number, location, color, size, height, lighting and landscaping of outdoor advertising signs and structures have been designed to minimize traffic hazard, positively affect the general appearance of the neighborhood and harmonize with adjacent development. No signs are proposed as part of this project. d) With respect to new projects within existing residential neighborhoods, new development should be designed to protect residents from noise, traffic, light and visually intrusive effects by use of buffering, setbacks, landscaping, walls and other appropriate design measures. This application is not a new development project. NOW, THEREFORE, BE IT RESOLVED: That after careful consideration of the maps, facts, exhibits, testimony, staff’s report and presentation, and other evidence submitted in this matter, subject to the conditions which are enumerated in this Resolution beginning on PAGE 3 thereof, The application for an Architectural and Site Approval, Application no. ASA-2019-007 is hereby approved and that the subconclusions upon which the findings and conditions specified in this resolution are based and contained in the Public Meeting record Draft Resolution ASA-2019-007 May 14, 2020 Page 4 concerning Application no. ASA-2019-007 as set forth in the Minutes of the Administrative Hearing Meeting of May 14, 2020 and are incorporated by reference as though fully set forth herein. SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPARTMENT 1. APPROVED EXHIBITS Approval is based on the plan set drawn by Baskervill titled “Spectrum Development Group, Courtyard by Marriott – San Jose Cupertino, CA – 10605 N. Wolfe Rd., Cupertino, CA 95014 Exterior Reimage” consisting of 52 sheets labeled T.001, A.001, A.002, A.010, A.011, A.012, A.013, A.110, A.111, A.114, A.201, A.202, A.203, A.204, A.211, A.212, A.213, A.214, A.401a, A.401b, A.401c, A.402a, A.402b, A.402c, A.403a, A.403b, A.403c, A.403d, A.404a, A.405, A.406, D.110, D.111, D.114, D.201, D.202, D.301, E.001, E.101, E.102, E.103, E.104, E.201, E.202, G.001, G.002, L.001, L.002, L.003, L.004, P.114, and PD.114, except as may be amended by conditions in this resolution. Sheets S0.0, S1.0, S2.0, S2.1, S3.0, S4.0, S5.0, S5.1, and S6.0 were neither reviewed nor approved as part of this project. 2. ACCURACY OF PROJECT PLANS The applicant/property owner is responsible to verify all pertinent property data including but not limited to property boundary locations, building setbacks, property size, building square footage, any relevant easements and/or construction records. Any misrepresentation of any property data may invalidate this approval and may require additional review. 3. CONCURRENT APPROVAL CONDITIONS The conditions of approval contained in file no. TR-2019-034 shall be applicable to this approval. 4. ANNOTATION OF THE CONDITIONS OF APPROVAL The conditions of approval set forth shall be incorporated into and annotated on the first page of the building plans. 5. EXTERIOR BUILDING MATERIALS/TREATMENTS a. The final building exterior plan shall closely resemble the details shown on the original approved plans. b. All final building exterior treatment plan (including but not limited to details on exterior color, materials, architectural treatments, doors, windows, lighting fixtures, and/or embellishments) shall be reviewed and approved by the Draft Resolution ASA-2019-007 May 14, 2020 Page 5 Director of Community Development prior to issuance of building permits to ensure quality and consistency. c. Any exterior changes determined to be substantial by the Director of Community Development shall either require a modification to this permit or a new permit based on the extent of the change. 6. LANDSCAPE PROJECT SUBMITTAL Prior to issuance of building permits, the applicant shall submit a full Landscape Documentation Package, per sections 14.15.050 A, B, C, and D of the Landscape Ordinance, for projects with landscape area 500 square feet or more The Landscape Documentation Package shall be reviewed and approved to the satisfaction of the Director of Community Development prior to issuance of building permits, and additional requirements per sect ions 14.15.050 E, F, G, H, and I will be required to be reviewed and approved prior to final inspections. 7. LANDSCAPE INSTALLATION REPORT The project is subject to all provisions delineated in the Landscape Ordinance (CMC, Chapter 14.15). A landscape installation audit shall be conducted by a certified landscape professional after the landscaping and irrigation system have been installed. The findings of the assessment shall be consolidated into a landscape installation report. The landscape installation report shall include but is not limited to: inspection to confirm that the landscaping and irrigation system are installed as specified in the landscape and irrigation design plan, system tune-up, system test with distribution uniformity, reporting overspray or run-off that causes overland flow, and preparation of an irrigation schedule. The landscape installation report shall include the following statement: “The landscape and irrigation system have been installed as specified in the landscape and irrigation design plan and complies with the criteria of the ordinance and the permit.” 8. LANDSCAPE AND IRRIGATION MAINTENANCE Per the Landscape Ordinance (CMC, Chapter 14.15), a maintenance schedule shall be established and submitted to the Director of Community Development or his/her designee, either with the landscape application package, with the landscape installation report, or any time before the landscape installation report is submitted. a. Schedules should take into account water requirements for the plant establishment period and water requirements for established landscapes. b. Maintenance shall include, but not be limited to the following: routine inspection; pressure testing, adjustment and repair of the irrigation system; Draft Resolution ASA-2019-007 May 14, 2020 Page 6 aerating and de-thatching turf areas; replenishing mulch; fertilizing; pruning; replanting of failed plants; weeding; pest control; and removing obstructions to emission devices. c. Failed plants shall be replaced with the same or functionally equivalent plants that may be size-adjusted as appropriate for the stage of growth of the overall installation. Failing plants shall either be replaced or be revived through appropriate adjustments in water, nutrients, pest control or other factors as recommended by a landscaping professional. 9. SIGNAGE Signage is not approved with this application. Signage shall conform to the City Sign Code. 10. LIGHTING On-site lighting must be in conformance with Cupertino Municipal Code Chapters 19.60 and 19.124. 11. DEMOLITION REQUIREMENTS All demolished building and site materials shall be recycled to the maximum extent feasible subject to the Building Official. The applicant shall provide evidence that materials were recycled prior to occupancy. 12. GRADING AND CONSTRUCTION HOURS AND NOISE LIMITS The applicant shall indicate compliance with the following grading and construction hours and noise limit requirements on all demolition, construction and grading permits, and in the construction management plan(s), unless otherwise indicated. a. All grading activities shall be limited to the dry season (April 15 to October 1), unless permitted otherwise by the Director of Public works. b. Construction hours and noise limits shall be compliant with all requirements of Chapter 10.48 of the Cupertino Municipal Code. c. Grading, street construction, underground utility and demolition hours for work done more than 750 feet away from residential areas shall be limited to Monday through Friday, 7 a.m. to 8 p.m. and Saturday and Sunday, 9 a.m. to 6 p.m. Grading, street construction, demolition or underground utility work within 750 feet of residential areas shall not occur on Saturdays, Sundays, holidays, and during nighttime period as defined in Section 10.48.053(b) of the Municipal Code. d. Construction activities shall be limited to Monday through Fr iday, 7 a.m. to 8 p.m. and Saturday and Sunday, 9 a.m. to 6 p.m. Construction activities are not Draft Resolution ASA-2019-007 May 14, 2020 Page 7 allowed on holidays as defined in Chapter 10.48 of the Municipal Code. Night time construction is allowed if compliant with nighttime standards of Section 10.48 of the Cupertino Municipal Code. e. Rules and regulations pertaining to all construction activities and limitations identified in this permit, along with the name and telephone number of an applicant appointed disturbance coordinator, shall be posted in a prominent location at the entrance to the job site. f. The applicant shall be responsible for educating all contractors and subcontractors of said construction restrictions. 13. BAAQMD BASIC CONTROL MEASURES (DUST CONTROL) Project shall comply with the Bay Area Quality Management District’s Basic Construction Mitigation Measures as follows: a. All exposed surfaces (e.g., parking areas, staging areas, soil piles, graded areas, and unpaved access roads) shall be watered two times per day. b. All haul trucks transporting soil, sand, or other loose material off-site shall be covered. c. All visible mud or dirt tracked-out onto adjacent public roads shall be removed using wet power vacuum street sweepers at least once per day. The use of dry power sweeping is prohibited. d. All vehicle speeds on unpaved roads shall be limited to 15 mph. e. All roadways, driveways, and sidewalks to be paved shall be completed as soon as possible. Building pads shall be laid as soon as possible after grading unless seeding or soil binders are used. f. Idling times shall be minimized either by shutting equipment off when not in use or reducing the maximum idling time to 5 minutes (as required by the California airborne toxics control measure Title 13, Section 2485 of California Code of Regulations [CCR]). Clear signage shall be provided for construction workers at all access points. g. All construction equipment shall be maintained and properly tuned in accordance with manufacturer’s specifications. All equipment shall be checked by a certified mechanic and determined to be running in proper condition prior to operation. h. A publicly visible sign shall be posted with the telephone number and person to contact at the City of Cupertino regarding dust complaints. This person shall respond and take corrective action within 48 hours. The BAAQMD phone number shall also be visible to ensure compliance with applicable regulations. Draft Resolution ASA-2019-007 May 14, 2020 Page 8 Applicant shall indicate compliance with BAAQMD’s basic control measures on all demolition, construction and grading permits and construction management plan(s). 14. CONSULTATION WITH OTHER DEPARTMENTS The applicant is responsible to consult with other departments and/or agencies with regard to the proposed project for additional conditions and requirements. Any misrepresentation of any submitted data may invalidate an approval by the Community Development Department. 15. INDEMNIFICATION The applicant agrees that, to the fullest extent permitted by law, the applicant shall indemnify, defend with the attorneys of the City’s choice, and hold harmless the City, its City Council, and its officers, employees, and agents (collectively, the “indemnified parties”) from and against any liability, claim, action, cause of action, suit, damages, judgment, lien, levy, or proceeding brought by a third party against one or more of the indemnified parties or one or more of the indemnified parties and the applicant related to any Ordinance, Resolution, or action approving the project, the related entitlements, environmental review documents, finding or determinations, or any other permit or approval authorized for the project, including (without limitation) reimbursing the City its actual attorneys’ fees and costs incurred in defense of the litigation. The applicant shall pay such attorneys’ fees and costs within 30 (thirty) days following receipt of invoices from City. Such attorneys’ fees and costs shall include amounts paid to the City’s outside counsel and shall include City Attorney time and overhead costs and other City staff overhead costs and any costs directly related to the litigation reasonably incurred by City. The applicant shall likewise indemnify, defend, and hold harmless the indemnified parties from and against any damages, attorneys’ fees, or costs awards, including attorneys’ fees awarded under Code of Civil Procedure section 1021.5, assessed or awarded against the indemnified parties. The Applicant further agrees to defend, indemnify and hold harmless the indemnified parties for all cost incurred in additional investigation or study of, or for supplementing, redrafting, revising, or amending any document (such as an Environmental Impact Report, negative declaration, specific plan, or general plan amendment) if made necessary by proceedings challenging the project approvals and related environmental review if the applicant desires to continue to pursue the project. Draft Resolution ASA-2019-007 May 14, 2020 Page 9 16. NOTICE OF FEES, DEDICATIONS, RESERVATIONS, OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90-day approval period in which you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90-day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. SECTION IV: CONDITIONS ADMINISTERED BY THE ENVIRONMENTAL SERVICES DEPARTMENT 17. TRASH ENCLOSURE MODIFICATION SHEET A.406: Please reconfigure the storm drain within the trash enclosure to an area outside of the structure. The full trash capture device identified should remain on the relocated storm drain inlet. Please note that the Sanitary District may require a sanitary drain within the enclosure with a filte r system. Please inquire directly with them for their requirements. SHEETS A.110, A.406, and Page 12 of Exhibit A (1987 topographic site survey): Please identify the location of the relocated storm drain inlet from the trash enclosure. Include the specific model of full trash capture device to be installed to the inlet. SECTION V: CONDITIONS ADMINISTERED BY THE FIRE DEPARTMENT 18. FIRE SPRINKLER MODIFICATIONS This building is equipped with a fire sprinkler system. Any modifications to the structure may require modification of the fire sprinkler system and will be determined during architectural review. A State of California licenses (C-16) Fire Protection Contractor shall submit plans, calculations, a completed permit application and appropriate fees to this department for review and approval prior to beginning their work. Call (408) 378-4010 for more information. 19. FIRE ALARM SYSTEM This building is equipped with a fire alarm system. Any modifications to the structure may require modification of the fire alarm system and will be determined Draft Resolution ASA-2019-007 May 14, 2020 Page 10 during architectural review. Any modifications to the current system will require submittal of shop drawings (3 sets) and a permit application to the Fire Prevention Division for review and approval before installing the system. Call (408) 378-4010 for more information. 20. EXITING All required exits and paths of egress shall be kept unobstructed and maintained at all times. 21. FIRE LANE & HYDRANTS All fire lanes shall be maintained and unobstructed access provided to fire hydrants at all times. 22. CONSTRUCTION SITE FIRE SAFETY All construction sites must comply with applicable provisions of the CFC Chapter 33 and our Standard Detail and Specification SI-7. Provide appropriate notations on subsequent plan submittals, as appropriate to the project. CFC Chp. 33. PASSED AND ADOPTED this 14th day of May 2020 at a noticed Public Meeting of the Administrative Hearing Officer of the City of Cupertino, State of California, held by the Director of Community Development, or his or her designee, pursuant to Cupertino Municipal Code Section 19.12.120. ATTEST: APPROVED: Erika Poveda Albert Salvador Associate Planner Assistant Director of Community Development TR-2019-034 CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 DRAFT RESOLUTION OF THE ADMINISTRATIVE HEARING OFFICER OF THE CITY OF CUPERTINO APPROVING A TREE REMOVAL PERMIT TO ALLOW THE REMOVAL AND REPLACEMENT OF FIFTEEN PROTECTED TREES LOCATED AT 10605 N. WOLFE ROAD SECTION I: PROJECT DESCRIPTION Application No.: TR-2019-034 Applicant: Tom Young (Spectrum Development) Location: 10605 N. Wolfe Road (APN 316-47-049) SECTION II: FINDINGS TREE REMOVAL PERMIT: WHEREAS, the City of Cupertino received an application for a Tree Removal permit as described in Section I of this Resolution; and WHEREAS, the necessary public notices have been given as required by the Procedural Ordinance of the City of Cupertino, and the Administrative Hearing Officer has held at least one public meeting in regard to the application; and WHEREAS, pursuant to the provisions of the California Environmental Quality Act of 1970 (Public Resources Code section 21000 et seq.) (“CEQA”), together with the State CEQA Guidelines (California Code of Regulations, Title 14, Section 15000 et seq.) (hereinafter, "CEQA Guidelines"), the City staff has independently studied the proposed Project and has determined that the Project is exempt from environmental review pursuant to the categorical exemption in CEQA Guidelines section 15304 for the reasons set forth in the staff report dated May 14, 2020 and incorporated herein; and WHEREAS, the applicant has met the burden of proof required to support said application; and WHEREAS, the Administrative Hearing Officer finds as follows with regard to this application: Draft Resolution TR-2019-034 May 14, 2020 Page 2 1. That the protected trees are a detriment to the subject property and cannot be adequately supported according to good urban forestry practices due to the overplanting or overcrowding of trees on the subject property. The proposed tree removals are supported due to poor initial planting locations not suitable for the continued growth and maintenance of the trees. The proposed tree replacements will improve the aesthetics of the site for its users. The City’s consulting arborist has reviewed the arborist report and takes no exception to the proposal for removal. NOW, THEREFORE, BE IT RESOLVED: That after careful consideration of the maps, facts, exhibits, testimony, staff’s report and presentation, and other evidence submitted in this matter, subject to the conditions which are enumerated in this Resolution beginning on PAGE 2 thereof: The application for a Tree Removal permit, Application no. TR-2019-034 is hereby approved and that the subconclusions upon which the findings and conditions specified in this resolution are based and contained in the Public Meeting record concerning Application no. TR-2019-034 as set forth in the Minutes of the Administrative Hearing Meeting of May 14, 2020 and are incorporated by reference as though fully set forth herein. SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPT. 1. APPROVED EXHIBITS This approval for tree removal is based on the certified arborist report prepared by Lori Murphy (ISA Certified Arborist, WE-7844AM) with Davey Resource Group, dated September 4, 2019 and consisting of 24 pages; and the tree replacement plan drawn by licensed landscape architect, Melvin R. Easter (LA # 4128), consisting of one (1) page labeled L.002, except as may be amended by conditions in this resolution. 2. ACCURACY OF PROJECT PLANS The applicant/property owner is responsible to verify all pertinent property data including but not limited to property boundary locations, building setbacks, property size, building square footage, any relevant easements and/or construction records. Any misrepresentation of any property data may invalidate this approval and may require additional review. 3. CONCURRENT APPROVAL CONDITIONS The conditions of approval contained in file no. ASA-2019-007 shall be applicable to this approval. Draft Resolution TR-2019-034 May 14, 2020 Page 3 4. PREVIOUS CONDITIONS OF APPROVAL All previous conditions of approval, in accordance with TR-2010-12 shall remain in effect except as may be amended by conditions contained in this resolution. 5. TREE #3 TO BE RETAINED This approval is for the removal of the fifteen (15) protected trees outlined in the certified arborist report with the exception of Tree #3, 6” DBH Cherry Plum (Prunus cerasifera), as indicated in the arborist’s Tree Inventory. Tree #3 shall be retained on site and protected. 6. FINAL PLANTING PLAN The applicant shall plant replacement trees in accordance with the replacement requirements of the Protected Tree Ordinance. The trees shall be planted prior to final occupancy of site permits. The final planting plan shall be reviewed and approved by the Director of Community Development prior to issuance of building permits. The Director of Community Development shall have the discretion to require additional tree replacements as deemed necessary. An ISA Certified Arborist shall confirm that the replacement trees were planted properly and according to plan prior to final occupancy. 7. TREE REPLACEMENTS The applicant is required to plant replacement trees in accordance with the Protected Tree Ordinance and per the approved replacement plan. 8. TREE PROTECTION As part of the demolition or building permit drawings, a tree protection plan shall be prepared by a certified arborist for the trees to be retained. In addition, the following measures shall be added to the protection plan: a. For trees to be retained, chain link fencing and other root protection shall be installed around the dripline of the tree prior to any project site work. b. Signs indicating the protected status of the tree shall be installed on the protective fencing. c. Tree protection conditions shall be posted on the tree protection fencing. d. No parking or vehicle traffic shall be allowed under root zones, unless using buffers approved by the Project Arborist. e. No trenching within the critical root zone area is allowed. If trenching is needed in the vicinity of trees to be retained, the City’s consulting arborist shall be consulted before any trenching or root cutting beneath the dripline of the tree. Draft Resolution TR-2019-034 May 14, 2020 Page 4 f. Wood chip mulch shall be evenly spread inside the tree projection fence to a four- inch depth. g. Retained trees shall continue to be irrigated or hand-watered to maintain them in good health. The tree protection measures shall be inspected and approved by the certified arborist prior to issuance of building permits. The City’s consulting arborist shall inspect the trees to be retained and shall provide reviews prior to issuance of demolition, grading or building permits. Additionally, a report ascertaining the good health of the trees mentioned above shall be provided prior to issuance of final occupancy. Any trees identified to be in poor health or incongruent with the site-wide tree replacement plan in the report shall be required to be removed and replaced. 9. TREE AND LANDSCAPE MAINTENANCE The property owner shall be responsible for ensuring that the existing trees and newly planted trees are properly maintained including but not limited to ensuring that there is adequate soil drainage, that the soil is well-aerated, and irrigation systems are thoroughly tested to provide sufficient water to landscaped areas while reducing water waste. 10. DISCLOSURE OF PROTECTED TREES AND COVENANT The property owner/applicant understands that the replacement trees may not be removed without a Tree Removal Permit and that they shall be responsible for ensuring the ongoing proper maintenance and care of the trees. The location and species of all replacements trees on site shall be disclosed upon sale of the property. In addition, a covenant shall be recorded on the property that identifies all the protected trees, prior to final occupancy. 11. CONSULTATION WITH OTHER DEPARTMENTS The applicant is responsible for consulting with other departments and/or agencies with regard to the proposed project for additional conditions and requirements. Any misrepresentation of any submitted data may invalidate an approval by the Community Development Department. 12. INDEMNIFICATION The applicant agrees that, to the fullest extent permitted by law, the applicant shall indemnify, defend with the attorneys of the City’s choice, and hold harmless the City, its City Council, and its officers, employees, and agents (collectively, the “indemnified parties”) from and against any liability, claim, action, cause of action, suit, damages, judgment, lien, levy, or proceeding brought by a third party against one or more of Draft Resolution TR-2019-034 May 14, 2020 Page 5 the indemnified parties or one or more of the indemnified partie s and the applicant related to any Ordinance, Resolution, or action approving the project, the related entitlements, environmental review documents, finding or determinations, or any other permit or approval authorized for the project, including (without l imitation) reimbursing the City its actual attorneys’ fees and costs incurred in defense of the litigation. The applicant shall pay such attorneys’ fees and costs within 30 (thirty) days following receipt of invoices from City. Such attorneys’ fees and costs shall include amounts paid to the City’s outside counsel and shall include City Attorney time and overhead costs and other City staff overhead costs and any costs directly related to the litigation reasonably incurred by City. The applicant shall likewise indemnify, defend, and hold harmless the indemnified parties from and against any damages, attorneys’ fees, or costs awards, including attorneys’ fees awarded under Code of Civil Procedure section 1021.5, assessed or awarded against the indemnified parties. The Applicant further agrees to defend, indemnify and hold harmless the indemnified parties for all cost incurred in additional investigation or study of, or for supplementing, redrafting, revising, or amending any document (such as an Environmental Impact Report, negative declaration, specific plan, or general plan amendment) if made necessary by proceedings challenging the project approvals and related environmental review if the applicant desires to continue to pursue the project. 13. NOTICE OF FEES, DEDICATIONS, RESERVATIONS, OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90 -day approval period in which you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90-day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. PASSED AND ADOPTED this 14th day of May 2020 at a noticed Public Meeting of the Administrative Hearing Officer of the City of Cupertino, State of California, held by the Director of Community Development, or his or her designee, pursuant to Cupertino Municipal Code Section 19.12.120. Draft Resolution TR-2019-034 May 14, 2020 Page 6 ATTEST: APPROVED: Erika Poveda Albert Salvador Associate Planner Assistant Director of Community Development USE GROUP:A-3 / B / R-1 (NO CHANGE) CONSTRUCTION TYPE (602):TYPE VA (NO CHANGE) FULLY SPRINKLERED:YES (NO CHANGE) FIRE ALARM SYSTEM:YES (NO CHANGE) HEIGHT OF BUILDING:47'-6 1/2" (3 STORIES) (NO CHANGE) HIGH RISE:NO (NO CHANGE) BUILDING CODES:2016 CALIFORNIA BUILDING CODE, VOLUME 1 & 2 2016 CALIFORNIA EXISTING BUILDING CODE MECHANICAL CODE:2016 CALIFORNIA MECHANICAL CODE PLUMBING CODE:2016 CALIFORNIA PLUMBING CODE ELECTRICAL CODE:2016 CALIFORNIA ELECTRICAL CODE FIRE CODE:2016 CALIFORNIA FIRE CODE ACCESSIBILITY CODE:2016 CALIFORNIA BUILDING CODE, VOLUME 1 & 2 ENERGY CODE:2016 CALIFORNIA ENERGY CODE 2016 CALIFORNIA GREEN BUILDING STANDARD CODE CUPERTINO MUNICIPAL CODE ASSESSOR'S PARCEL NUMBER:316-47-019 ZONING AND LAND USE: ZONING - P(HOTEL); LAND USE - COMMERCIAL RESIDENTIAL FLOOR AREA RATIO (FAR):BUILDING AREA: 79,406 SQ.FT LOT AREA: 154,624 SQ. FT EXISTING FAR = 0.51 PROPOSED FAR (NO CHANGE) LOT COVERAGE:EXISTING = 35,223 SF PROPOSED = 35,911 SF THIS IS FOR RENOVATION OF AN EXISTING HOTEL. THE EXTERIOR SCOPE INCLUDES A NEW ARRIVAL PORTE COCHERE, NEW FEATURE FRAMES/ BUILD OUTS AT THE MAIN ENTRY AND SIDE ENTRIES, BICYCLE PARKING, LANDSCAPING ENHANCEMENT, EXTERIOR MATERIAL UPGRADES, A NEW TRASH ENCLOSURE, REMOVAL OF EXISTING TREES AND PLANTING OF NEW TREES. GUESTROOMS ARE NOT INCLUDED IN PROJECT SCOPE. NO CHANGES TO EXISTING MEANS OF EGRESS D PROJECT SITE AREA IN SCOPE AREA NOT IN SCOPE - BICYCLE PARKING COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA 10605 N WOLFE RD, CUPERTINO, CA 95014 SPECTRUM DEVELOPMENT GROUP COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:54:40 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtTITLE SHEET 05/14/2019 - PERMIT SET T.001 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA CODE DATA SUMMARY.DESCRIPTION OF WORK. VICINITY MAP. DRAWING INDEX. SHEET NO SHEET TITLE REV NO REV DATE T.001 TITLE SHEET D 02/07/2020 G.001 3D VIEWS A 07/03/2019 G.002 3D VIEWS A 07/03/2019 S0.0 GENERAL NOTES C 11/20/2019 S1.0 KEY PLAN S2.0 FOUNDATION PLANS - ENTRANCE AND STAIRS S2.1 ROOF FRAMING PLANS - ENTRANCE S3.0 ROOF FRAMING PLANS - STAIRS AND AWNINGS S4.0 FOUNDATION DETAILS S5.0 ROOF FRAMING DETAILS S5.1 ROOF FRAMING DETAILS S6.0 TRASH ENCLOSURE C 11/20/2019 L.001 EXISTING CONDITIONS & DEMOLITION PLAN C 11/20/2019 L.002 PLANTING PLAN C 11/20/2019 L.003 LANDSCAPE DETAILS, NOTES, & SCHEDULE C 11/20/2019 L.004 PLANT IMAGE BOARD (EX. & PROPOSED) C 11/20/2019 A.001 GENERAL DRAWING STANDARDS & NOTES A.002 WINDOW TYPES, FRAME TYPES & SCHEDULE A.010 EXISTING CONDITIONS - PHOTOGRAPHIC DOCUMENTATION A.011 SITE PLAN - ACCESSIBILITY A.012 CONSTRUCTON MANAGEMENT PRACTICES A.013 CALGREEN D.110 DEMOLITION - SITE PLAN D 02/07/2020 D.111 DEMOLITION - 1ST FLOOR PLAN A 07/03/2019 D.114 DEMOLITION PLAN - ROOF A 07/03/2019 D.201 DEMOLITION - EXTERIOR ELEVATIONS D 02/07/2020 D.202 DEMOLITION - EXTERIOR ELEVATIONS - COURTYARD D 02/07/2020 D.301 DEMOLITION WALL SECTIONS D 02/07/2020 A.110 OVERALL PLANS - SITE D 02/07/2020 A.111 OVERALL PLANS - 1ST FLOOR PLAN D 02/07/2020 A.114 ROOF PLAN D 02/07/2020 A.201 EXTERIOR ELEVATIONS D 02/07/2020 A.202 EXTERIOR ELEVATIONS - COURTYARD D 02/07/2020 A.203 EXTERIOR ELEVATIONS, COLOR D 02/07/2020 A.204 EXTERIOR ELEVATIONS - COURTYARD, COLOR D 02/07/2020 A.211 ELEVATIONS - EXISTING & PROPOSED D 02/07/2020 A.212 ELEVATIONS - EXISTING & PROPOSED D 02/07/2020 A.213 ELEVATIONS - EXISTING & PROPOSED D 02/07/2020 A.214 ELEVATIONS - EXISTING & PROPOSED D 02/07/2020 A.401a ENLARGED PORTE COCHERE PLANS, REFLECTED CEILING PLANS & ROOF PLANS A.401b ENLARGED PORTE COCHERE SECTIONS AND ELEVATIONS A.401c DETAILS - PORTE COCHERE A.402a ENLARGED PLANS - MAIN ENTRANCE A.402b ENLARGED SECTIONS - MAIN ENTRANCE A.402c DETAILS - MAIN ENTRANCE A.403a ENLARGED PLANS, REFLECTED CEILING PLANS & DETAILS - FRONT STAIRCASE #1 & #2 A.403b ENLARGED ELEVATIONS - FRONT STAIRCASE #1 & #2 A.403c ENLARGED SECTIONS & DETAILS - FRONT STARICASE #1 & #2 A.403d DETAILS - FRONT STIARCASE A.404a ENLARGED PLANS, REFLECTED CEILING PLANS & DETAILS - SIDE ENTRANCE C 11/20/2019 A.405 ENLARGED PLANS, REFLECTED CEILING PLANS & DETAILS - REAR STAIRCASE A 07/03/2019 A.406 TRASH ENCLOSURE DETAILS D 02/07/2020 P.114 NEW WORK ROOF PLAN PD.114 DEMOLITION ROOF PLAN E.001 LEGEND, SPECS E.101 GROUND FLOOR - DEMOLITION E.102 GROUND FLOOR - NEW WORK C 11/20/2019 E.103 GROUND FLOOR - SITE PHOTOMETRICS C 11/20/2019 E.104 GROUND FLOOR - SITE BOUNDARY PHOTOMETRICS D 02/14/2019 E.201 ELEVATIONS E.202 ELEVATIONS BASKERVILL 101 S. 15TH ST., SUITE 200 (23219) P.O. BOX 400 RICHMOND, VA 23218-0400 PHONE: (804) 343-1010 WWW.BASKERVILL.COM CONTACT: TERRI CALLAWAY & ARCHITECT / INTERIORS / ENGINEER: DAVIDO CONSULTING GROUP, INC. 9706 4TH AVE NE, SUITE 300 SEATTLE, WA 98115 PHONE: (206) 523-0024 CONTACT: MATTHEW C. SCHMITTER STRUCTURAL ENGINEER: SPECTRUM DEVELOPMENT GROUP 3605 SANDY PLAINS ROAD SUITE 240 #414 MARIETTA, GA 30066 PHONE: (404) 229-6078 CONTACT: TOM YOUNG CLIENT : CLARION PARTNERS 1717 McKINNEY AVENUE SUITE 1900 DALLAS, TX 75202 OWNER: KEY PLAN - EXTERIOR REIMAGE EXTERIOR REIMAGE MARRIOTT INTERNATIONAL 10400 FERNWOOD RD BETHESDA, MD 20817 PHONE: (301) 380 6299 PURCHASING AGENT: VALERIE WARSHAW PROJECT ALTERNATIVES A 07/03/2019 PRELIMINARY REVIEW - REVISION B 09/05/2019 PRELIMINARY REVIEW - REVISION #2 C 11/20/2019 BUILDING PERMIT REVIEW - REVISION #3 D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 SURROUNDING USE MAP D 02/21/2020 A B C 1D2D3D4D5D6DD E 1E2E3E4E5E6E 1C2C3C4C5C6C 1B2B3B4B5B6B 1A2A3A4A5A6A 6 5 4 3 2 1 WINDOW TYPE (ALPHABETIC) COLUMN LINE WORK OR DATUM POINT CEILING TYPE / FINISH CEILING HEIGHT FINISH TAG (PLANS) DOOR NUMBER PARTITION TYPE DRAWING WHERE SHOWN SECTION CALL-OUT ELEVATION CALL-OUT DRAWING WHERE SHOWN DETAIL CALL-OUT DRAWING WHERE SHOWN KEYNOTE FURNITURE TYPE EE EXISTING NEW A4a C 1 REVISION (NUMERIC) ? C TAG 01 9' -0" A.F.F. ROOMNAME A123 123A ROOM NUMBER BUILDING PORTION (WHEN USED) 1A A101 SIM FURN A101 6AREF 6AREF 6AREF 6AREF A101 1A SIM N SW E 33.00° PROJECT NORTH DELTA BETWEEN TRUE & PROJECT NORTH TRUE NORTH F TAG 01 SHEET SEQUENCE VIEW TYPE MODIFIER 0 = DEMOLITION PLANS (OPTIONAL) 1 = FLOOR PLANS 2 = REFELECTED CEILING PLANS 3 = FINISH PLANS 4 = FF&E PLANS VIEW TYPE 0 = GENERAL / SCHEDULES 1 = PLANS 2 = EXTERIOR ELEVATIONS & DETAILS 3 = OVERALL BUILDING & EXTERIOR WALL SECTIONS 4 = ENLARGED PLANS 5 = INTERIOR ELEVATIONS & CASEWORK 6 = DETAILS DISCIPLINE T = TITLE SHEET & INDEX G = GENERAL B = GEOTECHNICAL / ENVIRONMENTAL D = DEMOLITION SERIES C = CIVIL L = LANDSCAPE A = ARCHITECTURAL / INTERIORS I = INTERIORS S = STRUCTURAL F = FIRE PROTECTION P = PLUMBING M = MECHANICAL / HVAC E = ELECTRICAL X = OTHER CONCRETE MASONRY (CMU) CONCRETE PRECAST CONCRETE BRICK STONE STEEL ALUMINUM POROUS FILL SOIL RIGID INSULATION BATT INSULATION GYPSUM DRYWALL PLASTER OR SAND PLYWOOD FRAMING LUMBER FINISH WOOD CERAMIC TILE ACOUSTICAL PANELS LIGHTWEIGHT CONC. TOPPING BLOCKING USE OF TOBACCO PRODUCTS IS NOT PERMITTED ANYWHERE ON OWNER'S PROPERTY. PROHIBIT USE OF ALL TOBACCO PRODUCTS, INCLUDING BUT NOT LIMITED TO CIGARETTES, CIGARS, PIPES, CHEWING TOBACCO, SNUFF, DIP, SNUS AND ELECTRONIC CIGARETTES BY ALL PERSONNEL COVERED BY THIS CONTRACT WHILE ON OWNER'S PROPERTY. THIS PROHIBITION APPLIES TO OCCUPANTS OF JOBSITE OFFICES, STORAGE OR WORK SHEDS, WORK AREAS ASSIGNED EXCLUSIVELY TO THE CONTRACTOR, AND VEHICLES WHILE THE VEHICLE IS ON OW NER'S PROPERTY. ENFORCE REQUIREMENTS STRICTLY. DEFINITION: THE TERM "DESIGN PROFESSIONAL" MEANS "ARCHITECT", "PROFESSIONAL ENGINEER", "INTERIOR DESIGNER" OR OTHER PARTY RESPONSIBLE FOR PROVIDING DESIGN SERVICES AS APPROPRIATE. 1. VERIFY ALL EXISTING CONDITIONS. 2. CONTRACTOR TO MAINTAIN EGRESS ROUTES FROM EXISTING BUILDING THROUGHOUT THE COURSE OF CONSTRUCTION. 3. VERTICAL DIMENSIONS ARE FROM "FLOOR LINE" UNLESS OTHERWISE NOTED. REFER TO ELEVATIONS FOR "FLOOR LINE" DATUMS. 4. HORIZONTAL DIMENSIONS FOR NEW CONSTRUCTION ARE FROM FACE OF FINISH UNLESS OTHERWISE NOTED. HORIZONTAL DIMENSIONS FOR EXISTING CONSTRUCTION ARE FROM FACE OF EXISTING FINISHED SURFACE. 5. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT, CONSULT WITH THE DESIGN PROFESSIONAL TO OBTAIN CLARIFICATION BEFORE CONTINUING WITH CONSTRUCTION. 6. HOLES CUT THROUGH EXISTING OR NEW FIRE RATED CONSTRUCTION FOR INSTALLATION OF PIPING, DUCTWORK, OR OTHER PENETRATIONS SHALL BE KEPT TO A MINIMUM NUMBER AND HELD TO A MINIMUM SIZE. FILL VOIDS BETWEEN PIPES, DUCTS, OTHER PENETRATING ITEMS AND RATED CONSTRUCTION WITH FIRE RETARDANT SEALANT SYSTEM LISTED IN THE UL FIRE RESISTANCE DIRECTORY WITH FIRE (F) AND TEMPERATURE (T) RATINGS EQUAL TO OR GREATER THAN THE FIRE RESISTANCE RATING OF THE ASSEMBLY BEING SEALED. 7. ALIGN NEW FLOOR FINISHES WITH EXISTING ADJACENT FLOOR FINISHES UNLESS OTHERWISE INDICATED WHERE NEW AND EXISTING FINISHED SURFACES ARE INDICATED TO BE ALIGNED, INSTALL SO FINISHED SURFACES ARE FLUSH (FEATHER MAXIMUM 1/8” PER FOUR FEET). 8. IT IS UNDERSTOOD AND AGREED THAT DRAWING REFINEMENTS, ADDITIONAL DETAILING AND CLARIFICATIONS WILL BE ISSUED DURING THE CONSTRUCTION SCHEDULE AND NO ADJUSTMENT WILL BE MADE IN THE CONTRACTORS’ OR SUB- CONTRACTORS’ PRICE UNLESS SUCH REFINEMENT, DETAILING OR CLARIFICATIONS RESULT IN CHANGES TO THE SCOPE, QUALITY, FUNCTION AND OR INTENT OF THE DRAWINGS AND THE PROJECT MANUAL NOT REASONABLY INFERABLE BY A CONTRACTOR OR SUB-CONTRACTOR EXPERIENCED IN THIS TYPE OF WORK. 9. ALL CONTRACTORS AND SUB-CONTRACTORS MUST QUOTE ON COMPLETED, FULLY OPERABLE SYSTEMS BASED ON THE DESIGN INTENT OF THE CONTRACT DOCUMENTS, AND ALL MATERIAL AND LABOR IMPLIED THEREFROM. 10. UNLESS OTHERWISE REQUIRED BY THE OWNER, CONSTRUCTION ADMINISTRATION SERVICES WILL BE COMPLETED USING NEWFORMA PROJECT CENTER. REFERENCE DIVISION 1 OF THE SPECIFICATION FOR THE PROCEDURES FOR REQUESTS FOR INFORMATION AND SUBMITTALS. 1. ALL FIREPROOFING DESIGNS SHOULD BE CONSIDERED THERMALLY UNRESTRAINED. 2. SPRAYED FIREPROOFING FOR STRUCTURAL MEMBERS WITH W/D OR A/P RATIOS OTHER THAN THE SPECIFIED UL DESIGN, WILL BE ADJUSTED IN ACCORDANCE WITH THE ADJUSTMENT OF SPRAYED PROTECTION MATERIAL THICKNESS FOR UNRESTRAINED RATINGS FOR VARIOUS BEAM AND COLUMN SIZES AS FOUND IN THE MOST CURRENT EDITION OF THE UL FIRE RESISTANCE DIRECTORY. 3. ALL BEAMS AND COLUMNS SHALL BE ADJUSTED USING W/D OR A/P RATIOS TO DETERMINE THE CORRECT FIREPROOFING THICKNESS. COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 12:14:04 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtGENERAL DRAWING STANDARDS & NOTES 05/14/2019 - PERMIT SET A.001 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA ABBREVIATIONS ABBRV FULL WORD LIN LINEAR LLV LONG LEG VERTICAL LVR LOUVER MAS MASONRY MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MEMB MEMBRANE MEZZ MEZZANINE MFR MANUFACTURER MIN MINIMUM MIR MIRROR MISC MISCELLANEOUS MLD MOLDING mm MILLIMETER MO MASONRY OPENING MT METAL THRESHOLD MTL METAL MULL MULLION MWK MILLWORK N NORTH NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OFCI OWNER FURNISHED CONTRACTOR INSTALLED OFF OFFICE OFOI OWNER FURNISHED OWNER INSTALLED OH OVERHEAD OPNG OPENING OPP OPPOSITE OPP H OPPOSITE HAND OVFL OVERFLOW #LBS POUNDS PAR PARALLEL PART PARTIAL PARTN PARTITION PERIM PERIMETER PERP PERPENDICULAR PL PLATE PLAM PLASTIC LAMINATE PLAS PLASTER, PLASTIC PLBG PLUMBING PLWD PLYWOOD PNL PANEL PNT PAINT PP PITCH POCKET PR PAIR PRV POWERED ROOF VENTILATOR PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PRESSURE TREATED, PORCELAIN TILE PWC PLASTIC WALL COVERING QT QUARRY TILE QTY QUANTITY QUAL QUALITY R RISER RA RETURN AIR RAD RADIUS RB RUBBER, RUBBER BASE RD ROOF DRAIN REBAR REINFORCING BAR RECEP RECEPTACLE, RECEPTION REF REFERENCE REFL REFLECTED REFR REFRIGERATOR REG REGULAR REINF REINFORCED REP REPAIR REQ REQUIRE, REQUIRED RESIL RESILIENT REV REVISION RFG ROOFING RH RIGHT HAND RL RAIN LEADER RM ROOM RO ROUGH OPENING RT RIGHT S SOUTH SC SOLID CORE SCHED SCHEDULE SCUP SCUPPER SD SOAP DISPENSER SECT SECTION SHT SHEET SHWR SHOWER SIM SIMILAR SND SANITARY NAPKIN DISPENSER SNR SANITARY NAPKIN RECEPTACLE SP STAND PIPE SPEC SPECIFICATION SPM SINGLE PLY MEMBRANE SS SERVICE SINK, STAINLESS STEEL SSM SOLID SURFACE MATERIAL ST STAINLESS STL STEEL STN STONE STOR STORAGE STRUCT STRUCTURAL SUSP SUSPENDED SV SHEET VINYL SYS SYSTEM T TREAD T GL TEMPERED GLASS T&G TONGUE & GROOVE TB TOWEL BAR TD TRENCH DRAIN TEL TELEPHONE TEMP TEMPERED, TEMPORARY TERR TERRAZZO THK THICK TLT TOILET TOC TOP OF CURB, TOP OF CONCRETE TOM TOP OF MASONRY TOS TOP OF STEEL TOSL TOP OF SLAB TTD TOILET TISSUE DISPENSER TWS THRU-WALL SCUPPER TYP TYPICAL UC UNDERCOUNTER, UNDERCUT UNFIN UNFINISHED UNO UNLESS NOTED OTHERWISE VB VAPOR BARRIER, VINYL BASE VC VALVE CABINET VCT VINYL COMPOSITION TILE VERT VERTICAL VEST VESTIBULE VIF VERIFY IN FIELD VIN VINYL VIT VITREOUS CHINA VNR VENEER VP VENT PIPE, VAPOR PROOF VTR VENT THRU ROOF VWC VINYL WALL COVERING W WIDTH W/ WITH W/O WITHOUT WAINS WAINSCOT WB WOOD BASE WC WALL COVERING, WATER CLOSET WD WOOD WG WIRE GLASS WH WATER HEATER WIN WINDOW WPR WATERPROOFING WPT WORK POINT WR WATER RESISTANT, WASTE RECEPTACLE WT WEIGHT WWF WELDED WIRE FABRIC ABBREVIATIONS ABBRV FULL WORD @ AT A/C AIR CONDITIONING AB ANCHOR BOLT AC ACOUSTICAL ACP ACOUSTICAL CEILING PANEL AD ACCESS DOOR ADJ ADJACENT, ADJUSTABLE AFF ABOVE FINISHED FLOOR AL ALUMINUM ALT ALTERNATE AP ARMOR PLATE APPROX APPROXIMATE ARCH ARCHITECTURAL AWC ACOUSTICAL WALL COVERING BC BRICK COURSES(ING) BLDG BUILDING BLK BLOCK BLKG BLOCKING BM BENCH MARK, BEAM BOT BOTTOM BRG BEARING BRK BRICK BSMT BASEMENT BUR BUILT UP ROOFING CB CATCH BASIN CF CUBIC FOOT (FEET) CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED CFM CUBIC FOOT PER MINUTE CG CORNER GUARD CHAN CHANNEL CHR CHAIR RAIL CI CAST IRON CIP CAST IN PLACE CJ CONTROL JOINT CLG CEILING CLO CLOSET CLR CLEAR cm CENTIMETER CMU CONCRETE MASONRY UNIT CO CLEAN OUT COL COLUMN COMP COMPOSITION, COMPOSITE CONC CONCRETE CONT CONTINUOUS CORR CORRIDOR CP CLEAR PLASTIC CPT CARPET CR CRASH RAIL CR/BG CRASH RAIL / BUMPER GUARD CT CERAMIC TILE CTR CENTER CV CHECK VALVE CW CLEAR WIRE GLASS CY CUBIC YARD CYL CYLINDER Ѥ CENTERLINE D DEPTH DBL DOUBLE DEG DEGREE DEMO DEMOLITION DET DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DIAG DIAGONAL DIFF DIFFUSER DIM DIMENSION DISP DISPENSER DIV DIVISION DN DOWN DP DAMPROOFING DR DOOR, DRAIN DS DOWNSPOUT DWG DRAWING DWGS DRAWINGS EA EACH EB EXPANSION BOLT EIFS EXTERIOR INSULATION AND FINISH SYSTEM EJ EXPANSION JOINT ELEC ELECTRICAL ELEV ELEVATOR, ELEVATION EMER EMERGENCY ENGR ENGINEER(ING) EPDM ETHYLENE PROPYLENE DIENE MONOMER (ROOF MEMBRANE) EQ EQUAL EQUIP EQUIPMENT ETR EXISTING TO REMAIN EWC ELECTRIC WATER COOLER EXIST EXISTING EXPA EXPANSION ANCHOR EXT EXTERIOR F FAHRENHEIT FA FIRE ALARM FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISH FLOOR FHC FIRE HOSE CABINET FIN FINISH(ED) FO FINISHED OPENING FOF FACE OF FINISH FOS FACE OF STUD FRTW FIRE RETARDANT TREATED WOOD FV FIELD VERIFIED FWC FABRIC WALL COVERING GA GAGE GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GEN GENERAL GL GLASS, GLAZING GND GROUND GNV GOOSE NECK VENTILATOR GR GROUT GYP GYPSUM GYP BD GYPSUM BOARD H HIGH HB HOSE BIBB HC HOLLOW CORE HD HEAVY DUTY HDW HARDWARE HGT HEIGHT HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR HRL HANDRAIL HVAC HEATING VENTILATING & AIR CONDITIONING HWD HARDWOOD ID INSIDE DIAMETER IN INCH INSUL INSULATION INT INTERIOR IPT INTERIOR PAINT JAN JANITOR JCT JUNCTION JST JOIST JT JOINT JT B JOINT BACKER KB KEYBOARD KIT KITCHEN KO KNOCKOUT KP KICK PLATE KS KNEE SPACE L LENGTH LAM LAMINATE, LAMINATED LAM GL LAMINATED GLASS LAV LAVATORY LB POUND LBF POUNDS-FORCE LH LEFT HAND SHEET LAYOUT GENERAL SYMBOLS DRAWING NUMBERS MATERIAL GRAPHICS TOBACCO FREE WORKZONE NOTES GENERAL NOTES FIREPROOFING NOTES 05/14/2019 SEALANT UNFACED BATT INSULATION, MIN R-13 ALUMINUM STOREFRONT SYSTEM 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER SHEATHING SILL PAN WITH END DAMS ON SEALANT BED ALUMINUM STOREFRONT SYSTEM SEALANT SHIM ELASTOMERIC COATING DRAINAGE FILL SLOPE GRADE AWAY FROM FOUNDATION 1/8"/FT MINIMUM BACKER ROD AND CONTINUOUS SEALANT BACKER ROD AND CONTINUOUS SEALANT METAL FLASHING SHIM SEALANT 5/8" GYP BD UNFACED BATT INSULATION, MIN R-13 ALUMINUM STOREFRONT SYSTEM BACKER ROD AND CONTINUOUS SEALANT BACKER ROD AND CONTINUOUS SEALANT 1" 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER SHEATHING 7'-4"8'-0"1B A.002 1A A.002 1C A.002 1/4" CLEARANCE FROM EDGE OF PANEL TO FLASHING "Z" FLASHING FIBER CEMENT PANELS ON PROPRIETARY CLIP SYSTEM NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION. INSULATION COMPRESSIVE STRENGTH OF 25 PSI NEW SHEATHING EXISTING WALL AND WINDOW TO REMAIN. FIELD CONDITION MAY VARY. GC TO VIF. REMOVE SHEATHING AND EIFS FINISH AND PREPARE TO RECEIVE NEW PROVIDE BUG SCREEN AT EXPOSED ENDS OF FIBER CEMENT PANEL WALLS EXIST WALL METAL FLASHING REMOVE EXISTING SEALANT, SECURE FLASHING, AND PROVIDE NEW SEALANT FIBER CEMENT PANEL FIBER CEMENT PANEL SPACER, PROPRIETARY, REFERENCE MANUFACTURER DETAILS CONT INSULATION, EXIST 5/8" GYP BOARD SHEATHING, EXIST NEW FLUID APPLIED VAPOR PERMEABLE AIR BARRIER PROPRIETARY CLIP SYSTEM, REFERENCE MANUFACTURER DETAILS DETAIL APPLIES TO EXISTING WINDOWS WHERE FIBER CEMENT PANELS ARE BEING APPLIED TO THE HOSTING WALL. PROPRIETARY SINGLE FLANGE SEALANT BACKER, REFERENCE MANUFACTURER DETAILS SEALANT "L" TRIM, PAINT FIBER CEMENT PANELS ON PROPRIETARY CLIP SYSTEM NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION. INSULATION COMPRESSIVE STRENGTH OF 25 PSI NEW SHEATHING EXISTING WALL AND WINDOW TO REMAIN. FIELD CONDITION MAY VARY. GC TO VIF. REMOVE SHEATHING AND EIFS FINISH AND PREPARE TO RECEIVE NEW COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 12:14:04 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtWINDOW TYPES, FRAME TYPES & SCHEDULE 05/14/2019 - PERMIT SET A.002 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 3" = 1'-0" DRAWING REF: A.0021CSTOREFRONT - JAMB DETAIL SCALE: 3" = 1'-0" DRAWING REF: A.0021ASTOREFRONT - SILL DETAIL SCALE: 3" = 1'-0" DRAWING REF: A.0021BSTOREFRONT HEAD DETAIL SCALE: 1/4" = 1'-0" DRAWING REF: A.1113AELEVATION - STOREFRONT SCALE: 3" = 1'-0" DRAWING REF: A.402c2BEXISTING WINDOW - HEAD DETAIL SCALE: 3" = 1'-0"2A EXISTING WINDOW SILL DETAIL SCALE: 3" = 1'-0"2C DETAIL - WINDOW JAMB 05/14/2019 DN 3 2 1 456 9 8 7 12 11 10 C2 C1 GREEN SCREEN AERIAL VIEW REAR PARKING REAR ENTRY VIEW - REAR PARKING VIEW FROM I280 PROPERTY BACKING UP TO INTERSTATE. VISIBILITY OF REAR ENTRANCES OBSCURED BY GREEN SCREEN FROM PUBLIC VIEW VIEW FROM N. WOOLF RD 1 2 3 4 5 6 7 8 9 101112 C1C2 COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 12:14:06 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtEXISTING CONDITIONS - PHOTOGRAPHIC DOCUMENTATION 05/14/2019 - PERMIT SET A.010 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA EXISTING CONDITIONS - PHOTOGRAPHIC DOCUMENTATION EXISTING CONDITIONS - PHOTOGRAPHIC DOCUMENTATION - PROPERTY VISIBILITY PHOTOGRAPHIC DOCUMENTATION - KEY PLAN 05/14/2019 DN DN ACCESSIBLE ENTRANCE ACCESSIBLE ENTRANCE ACCESSIBLE ENTRANCE ACCESSIBLE PARKING STALL VAN ACCESSIBLE PARKING STALL ACCESSIBLE PARKING STALL VAN ACCESSIBLE PARKING STALL VAN ACCESSIBLE PARKING STALL VAN ACCESSIBLE PARKING STALL ACCESSIBLE PATH OF TRAVELACCESSIBLE PATH OF TRAVEL ACCESSIBLE PATH OF TRAVEL ACCESSIBLE PATH OF TRAVEL ACCESSIBLE PATH OF TRAVEL ACCESSIBLE PATH OF TRAVEL ACCESSIBLE PATH OF TRAVEL PUBLIC RIGHT OF WAY/ PUBLIC SIDEWALK (SIDWALK ELEVATION MATCH ADJACENT PARKING ELEVATION - NO CURB RAMP REQUIRED) CURB RAMP CURB RAMP REFER TO 6B/A601 CURB RAMP REFER TO 6B/A601 CURB RAMP REFER TO 6B/A601 CURB RAMP REFER TO 6B/A601 CURB RAMP REFER TO 6B/A601 FEDERAL YELLOW TRUNCATED DOMES FEDERAL YELLOW TRUNCATED DOMES FEDERAL YELLOW TRUNCATED DOMES FEDERAL YELLOW TRUNCATED DOMES FEDERAL YELLOW TRUNCATED DOMES FEDERAL YELLOW TRUNCATED DOMES FEDERAL YELLOW TRUNCATED DOMES CURB RAMP NOTE: RAISED CURBS (+/- 4") SEPARATE SIDEWALKS FROM VEHICULAR AREAS, TYP. PARKING COUNT: TOTAL PARKING STALLS: 140 TOTAL ACCESSIBLE PARKING STALLS: 6 TOTAL VAN ACCESSIBLE PARKING STALLS: 4 REFER TO A601 FOR PARKING SPACE DETAILS FOR STALL SIZE, MARKING, AND SIGNAGE. ACCESSIBLE PATH OF TRAVEL TO PUBLIC RIGHT OF WAY/ PUBLIC SIDEWALK CURB RAMP REFER TO 6B/A6012'-0"MINIMUM FINE $250 INTERNATIONAL SYMBOL OF ACCESSIBILITY IN WHITE ON A DARK BLUE BACKGROUND - 70 SQIN60" MIN2" DIA GALVANIZED STEEL POST 24" INTO GROUND BY HOTEL OPERATIONS ACCESSIBLE PARKING ACCESSIBLE ROUTE80 MIN. ATVAN ACCESSIBLE MIN. 17"22" MIN.1" LETTERING STATING "UNAUTHORIZED" VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT OWNER'S EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT : ___________ OR BY TELEPHONING ______________." BLANK SPACES SHALL BE FILLED IN WITH APPROPRIATE INFORMATION AS A PERMANENT PART OF THE SIGN 216" MINIMUM108"96" INTERNATIONAL SYMBOL OF ACCESSIBILITY 36" BY 36" MIN. BLUE LINES HATCHED WHITE LINES 36" ON CENTER MAX. NO PARKING WHITE LETTERS 12" TALLEQEQ SIGNAGE REFER TO 4E/A.010 216" MINIMUM108"60" BLUE LINES HATCHED WHITE LINES 36" ON CENTER MAX. NO PARKING WHITE LETTERS 12" TALL INTERNATIONAL SYMBOL OF ACCESSIBILITY 36" BY 36" MIN. EQ EQ SIGNAGE REFER TO 4E/A.010 3'-0"SLOPE 1:12 MAXFOR 6'-0" +/-4'-0" MIN.4'-0" CROSS SLOPE OF 1:48 DETECTABLE WARNINGS 2"2" BRUSH CONCRETE WITH SLOPE OF 1:48 IN ALL DIRECTIONS BRUSH CONCRETE WITH SLOPE OF 1:48 IN ALL DIRECTIONS4'-0" MIN.COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 12:14:15 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtSITE PLAN - ACCESSIBILITY 05/14/2019 - PERMIT SET A.011 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 1/16" = 1'-0" DRAWING REF: A.401b6ASITE PLAN - ACCESSIBILITY SCALE: 1/2" = 1'-0"4E VAN PARKING SIGN SITE PLAN - ACCESSIBILITY AND SITE ACCESSIBILITY REQUIREMENTS. WORK NOT IN SCOPE FOR THIS DRAWING SET. SITE PLAN FOR REFERENCE ONLY. SCALE: 1/4" = 1'-0"3E VAN ACCESSIBLE PARKING DETAIL SCALE: 1/4" = 1'-0"2E ACCESSIBLE PARKING DETAIL SCALE: 1/4" = 1'-0"1E CURB RAMP DETAIL 05/14/2019 COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 12:14:15 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtCONSTRUCTON MANAGEMENT PRACTICES 05/14/2019 - PERMIT SET A.012 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA 05/14/2019 COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 3:29:25 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtCALGREEN 05/14/2019 - PERMIT SET A.013 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA 05/14/2019 DN DN 30 TOTAL COURTYARD - GC TO VIF 26.56.19.A 18 TOTAL EXTERIOR - GC TO VIF A.110 3E 10.14.00.C 10.14.00.C PARKING COUNT: TOTAL PARKING STALLS: 140 (NO CHANGE) TOTAL ACCESSIBLE PARKING STALLS: 6 (NO CHANGE) TOTAL VAN ACCESSIBLE PARKING STALLS: 4 (NO CHANGE) REFER TO A.011 FOR ACCESSIBLE PARKING SPACE DETAILS FOR STALL SIZE, MARKING, AND SIGNAGE. 4 BICYCLE PARKING STALLS PROVIDED BUILDING AREA: 79,406 SQ.FT PER CMC SECTION 19.124.040 - HOTEL = 20,000 SQ. FT / STALL 79,406 / 20,000 = 3,97 = 4 BICYCLE STALLS REQUIRED 149 GUESTROOMS (NO CHANGE) 18 NUMBER OF EMPLOYEES AT ANY GIVEN TIME 9'-0" TYP 25'-0" TYP18'-0" TYPPUBLIC RIGHT OF WAY/ PUBLIC SIDEWALK N WOLFE ROAD PUBLIC SIDEWALK EXISTING CHAIN LINK FENCE TO BE DEMOLISHED (+/- 6' HIGH) EXISTING TO REMAIN CHAIN LINK FENCE (+/- 6' HIGH) EXISTING TO REMAIN "DOG EAR" WOOD PRIVACY FENCE (+/- 6' HIGH) EXISTING TO REMAIN "DOG EAR" WOOD PRIVACY FENCE (+/- 6' HIGH) EXISTING TO REMAIN CHAIN LINK FENCE (+/- 12' HIGH) EXISTING TO REMAIN CHAIN LINK FENCE (+/- 6' HIGH) EXISTING TO REMAIN "DOG EAR" WOOD PRIVACY FENCE (+/- 6' HIGH) DRIVE 27'-10"DRIVE25'-0"DRI VE24' -8 1/4" DRIVE 25'-7 1/2"20'-0"24'-0" DRIVE 26'-6 3/4"DRIVE17'-3 1/2"DRIVE32'-7"1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 4746 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 89 88 87 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 72 71 70 69 73 74 75 76 77 78 79 80 81 82 83 84 85 86106107108109110111112113114115116117118119120121122123124125126127128129130131132 133134 135 136 137 138 139 140 PARKING STALLS NUMBERED FOR CLARITY 45 A.406 2A NEW WASTE TRIO STATION WITH CIGARETTE FILTER URN ATTACHMENT DRIVE24'-0"CB-8 CB-7 CB-6 CB-5 CB-4 NEW CURB CB-3 CB-2 CB-1 D 19'-2 3/4"15'-0" PROPERTY LINE D EXISTING EASEMENTABANDONED EASEMENT D D D NEW FENCE EXTENSION D 03.30.00.A 10.14.00.B 4'-0"4'-0"4'-0"12'-0"4'-0" 10'-6 3/4" BIKE RACK 4 BICYCLE STALLS 3'-0"10" MIN.4" MIN.1'-8" 9" MIN.2'-6"PROVIDE RELIANCE FOUNDRY R-7906 POST & RING BIKE BOLLARD NEW 4" REINFORCED CONCRETE SLAB, BROOM FINISH 4" MIN, COMPACT SUBGRADE EXPANSION JOINT EXISTING SIDE WALK ALIGN SLOPE TO DRAIN - GC TO VIF DIRECTION OF SLOPE IN FIELD 1/4" PER 12" LEGEND: NEW TRASH CAPTURE SYSTEM CB #1,REM TRITON BFTG-FTC FILTER DEVICES. (CONFIGURED WITH BIOFLEX TRASH GUARD (BFTG) MEDIA CARTRIDGE STRATEGY) TR24SR-D-FOG-BFTG-FTC DESIGNED FOR A 2' X 2' DROP CATCH BASIN CB #2 CB #3, 4, 5, 6, 7, 8 REM TRITON BFTG-FTC FILTER DEVICES. (CONFIGURED WITH BIOFLEX TRASH GUARD (BFTG) MEDIA CARTRIDGE STRATEGY.) TR2448-TH-BFTG-FTC CATCH BASIN ID - SEE PLAN CAPTURE DEVICE DESCRIPTION NOTE: ALL STORM DRAIN INLETS TO BE MARKED WITH NEW "NO DUMPING - FLOWS TO CREEK" SIGNAGE D D COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:53:13 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtOVERALL PLANS - SITE 05/14/2019 - PERMIT SET A.110 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA KEYNOTES 03.30.00.A *ADD ALT* PROVIDE NEW 4" MIN. REINFORCED CONCRETE SLAB. BROOM FINISH. 10.14.00.B *ADD ALT* PROVIDE "BICYCLE PARKING" SIGN 10.14.00.C SIGNAGE BY OTHERS. 26.56.19.A OFCI LIGHT BOLLARD. INSTALL IN EXISTING LIGHT BOLLARD LOCATION. REFER TO ELECTRICAL DRAWINGS FOR DETAILS NSWE100.00° SCALE: 1/16" = 1'-0" DRAWING REF: -A.404a6AOVERALL PLAN - SITE SCALE: 1/8" = 1'-0" DRAWING REF: A.1103E ADD ALT - ENLARGED PLAN BICYCLE PARKING SCALE: 1" = 1'-0"2E ADD ALT - BIKE RACK SECTION A 07/03/2019 PRELIMINARY REVIEW - REVISION C 11/20/2019 BUILDING PERMIT REVIEW - REVISION #3 D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 D 02/21/2020 DN DDREF.DWOOOOO O OO OO OOOODDDDODDDDO A.2014E A.201 A.201 A.201 6A 4C 6B A.202 6A 3E 6B 3C A.403a 1A A.405 1A A.403a 1C A.401a 3A A.402a 4A A.405 1A SIM. MIR. A.002 3A A.203 6A A.203 6B A.203 4C A.2034EA.204 6B A.204 3EA.2043CA.204 6A NO WORK IN THIS AREA POCHE LEGEND COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:53:15 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtOVERALL PLANS - 1ST FLOOR PLAN 05/14/2019 - PERMIT SET A.111 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 3/32" = 1'-0" DRAWING REF: -A.404a6AOVERALL PLAN - GROUND FLOOR KEYNOTES NSWE100.00° A 07/03/2019 PRELIMINARY REVIEW - REVISION D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 D 02/21/2020 A.2014E A.201 A.201 A.201 6A 4C 6B A.202 6A 3E 6B 3C A.402a 6A A.403a 5A A.403a 5C A.002 3A A.401a 5A A.203 6A A.203 6B A.203 4C A.2034EA.204 6B A.204 3EA.2043CA.204 6A FULLY ADHERED, CONTINUOUS TPO ROOF MEMBRANE FULLY ADHERED, CONTINUOUS TPO ROOF MEMBRANE FULLY ADHERED, CONTINUOUS TPO ROOF MEMBRANE FULLY ADHERED, CONTINUOUS TPO ROOF MEMBRANE FULLY ADHERED, CONTINUOUS TPO ROOF MEMBRANE D D D D D NO WORK IN THIS AREA POCHE LEGEND COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:53:16 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtROOF PLAN 05/14/2019 - PERMIT SET A.114 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA KEYNOTES NSWE100.00° SCALE: 3/32" = 1'-0" DRAWING REF: -A.404a6AOVERALLPLANS - ROOF A 07/03/2019 PRELIMINARY REVIEW - REVISION D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 D 02/21/2020 4C A.403c 09.91.13.A09.91.13.A 26.56.19.B 09.91.13.A 09.91.13.A 26.56.19.B 09.91.13.A EF-1 FC-1 EF-2 EF-2 EF-3 EF-3 EF-3 EF-1 EF-2 EF-1EF-1EF-1 EF-1 EF-2EF-1EF-2 EF-2 EF-1 TYP. EF-4 EF-4 09.91.13.A09.91.13.A 31.00.00.A NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 45'-6"NATURAL GRADE TO TOP OF PROPOSED PLATE33'-3 3/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 47'-6 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 33'-1 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 31'-8 1/2"MTL-2 AT UNDERSIDE OF PORTE COCHERE & CANOPYD 2'-0 3/4" (PARAPET)D D 09.91.13.A09.91.13.A 09.91.13.A09.91.13.A 09.91.13.A09.91.13.A 26.56.19.B26.56.19.B26.56.19.B26.56.19.B26.56.19.B26.56.19.B EF-2 EF-2EF-2 EF-3 EF-2EF-2 FC-1 EF-3 EF-2 EF-2 EF-2 EF-2 EF-2 EF-2 EF-1 EF-1 EF-1 EF-1 EF-1EF-1 EF-2 EF-2 EF-2 EF-1 EF-1 EF-1 EF-1 EF-2 EF-1 EF-2 EF-2 EF-2 EF-2 EF-2EF-1 EF-2EF-4 EF-4 09.91.13.A09.91.13.A NATURAL GRADE TO TOP OF PROPOSED PLATE31'-3 3/4"31.00.00.ANATURAL GRADE TO TOP OF EXISTING PLATE+/- 27'-2 1/2"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 42'-8"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/2"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"MTL-2 AT UNDERSIDE OF PORTE COCHERE & CANOPY D2'-0 3/4" (PARAPET)D D EF-2 TRASH ENCLOSURE EF-2 @ TRASH ENCLOSURE ROOF STRUCTURE D D 1A A.402b 6A A.402b 3C A.402b 3A A.402b EF-1 EF-1FC-1 EF-3 EF-2EF-2 EF-2 EF-2 EF-1 EF-2 EF-1EF-1 EF-2 EF-2 FC-1 EF-3 EF-2 EF-2 EF-2 EF-2 4A A.402b 09.91.13.A09.91.13.A 09.91.13.A09.91.13.A 09.91.13.A09.91.13.A 09.91.13.A09.91.13.A EF-3 FC-1 EF-1 EF-1 EF-1EF-1EF-1EF-1 NATURAL GRADE TO TOP OF PORTE COCHERE +/- 13'-2"31.00.00.A NATURAL GRADE TO TOP OF PROPOSED PLATE+/- 22'-10"12'-10"MTL-2 AT UNDERSIDE OF PORTE COCHERE D EF-2 @ TRASH ENCLOSURE WALLS, GATE, & ROOF STRUCTURE D EF-1 EF-1 EF-1EF-1 EF-2 EF-1EF-1EF-1 EF-1EF-2 EF-2 EF-2 EF-2 EF-1 EF-2 EF-2EF-2EF-2 5A A.405 5A A.405 SIM EF-2EF-2 EF-4 EF-4 NATURAL GRADE TO TOP OF EXISTING PLATE+/- 12'-10 3/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 19'-3 3/4"31.00.00.A EF-2 CEILING EF-1 EF-2 EF-2 PERPENDICULAR WALL PERPENDICULAR WALL EF-1 EF-1 EF-1 CEILING PERPENDICULAR WALL NOTE: AT LOCATIONS WHERE OUTSIDE FACE OF BALCONY WALL (PARKING LOT FACING) ARE INDICATED TO BE PAINTED EF-2, ALL LOCATIONS INDICATED TO BE PAINTED EF-1 IN THIS VIEW ARE TO BE PAINTED EF-2 EF-1 CEILING EF-1 CEILING EF-1 EF-1 PERPENDICULAR WALL PERPENDICULAR WALL EF-1 EF-1 COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:53:21 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtEXTERIOR ELEVATIONS 05/14/2019 - PERMIT SET A.201 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA KEYNOTES 09.91.13.A PAINT EXISTING TO REMAIN EIFS - REFER TO ELEVATIONS FOR COLORS. PAINT TRIMS, FASCIA, GUTTERS, RAIN LEADERS, HANDRAILS, GUARDRAIL, PTAC COVERS - MATCH ADJACENT EIFS WALL FINISH. 26.56.19.B OFCI EXTERIOR GRADE SCONE LIGHT. INSTALL IN EXISTING LIGHT LOCATION. REFER TO ELECTRICAL DRAWINGS FOR DETAILS 31.00.00.A NATURAL GRADE - AS PER GRADING PLAN DATED 10/25/86 BY SANDIS AND ASSOCIATES INC. ENGINEERS, SURVEYORS AND PLANNERS SCALE: 3/32" = 1'-0" DRAWING REF: A4106AELEVATION - EAST SCALE: 3/32" = 1'-0" DRAWING REF: A.1116BELEVATION - WEST SCALE: 3/32" = 1'-0" DRAWING REF: A.1114CELEVATION - NORTH SCALE: 3/32" = 1'-0" DRAWING REF: A.1114EELEVATION - SOUTH TYP. SCALE: 3/32" = 1'-0"6C ELEVATION - JACUZZY SCALE: 3/32" = 1'-0"5C ELEVATION - TYPICAL SIDE WALL AT BALCONIES WITH WING WALLS EXTERIOR FINISH LEGEND FINISH NO. MATERIAL MANUFACTURER STYLE NAME / NO. COLOR SIZE DESCRIPTION / REMARKS DRY STONE ST-01 DRY STONE HERITAGE STONE EIRE DRY STACK PROVIDE SAMPLE FOR FINAL APPROVAL BY ARCHITECT/MARRIOTT FIBER CEMENT WALL PANEL FC-1 FIBER CEMENT WALL PANEL NICHIHA VINTAGE WOOD CEDAR 18" x 10' x 5/8" W/ TAMLYN COORDINATED TRIM METAL CEILING PANEL MTL-2 METAL CEILING PANEL PAC-CLAD FLUSH SOLID WALL PANEL DARK BRONZE 12" CEILING OF PORTE COCHERE AND FRONT ENTRANCE CANOPY PAINT EF-1 PAINT SHERWIN WILLAIMS SNOWBOUND SW 7004 EF-2 PAINT BENJAMIN MOORE HEARTSONE SW 1601 EF-3 PAINT BENJAMIN MOORE GRAPHITE 1603 PT-3 PAINT SHERWIN WILLAIMS FIRETEX FX5090 TO MATCH PAC-CLAD DARK BRONZE EGGSHELL FOR (4) EXPOSED STEEL COLUMNS AND (2) EXPOSED BEAMS @ PORTE COCHERE PT-4 PAINT SHERWIN WILLAIMS PRO-INDUSTRIAL PRE-CATYLYZED WATER BASED EPOXY TRICORN BLACK SW 6258 EXTERIOR RAILINGS PT-5 PAINT SHERWIN WILLAIMS PRO-INDUSTRIAL PRE-CATYLYZED WATER BASED EPOXY TO MATCH POR-CLAD DARK BRONZE CANOPY SOFFIT EF-4 PAINT SHERWIN WILLIAMS PORTABELLO SW6102 A 07/03/2019 PRELIMINARY REVIEW - REVISION C 11/20/2019 BUILDING PERMIT REVIEW - REVISION #3 D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 D D D D 02/21/2020 09.91.13.A09.91.13.A EF-1 EF-4 EF-1 EF-2EF-2 EF-1 EF-2 EF-1 EF-2 EF-1 EF-1 EF-1 EF-3 EF-1EF-1 26.56.19.B TYP.NATURAL GRADE TO TOP OF PROPOSED PLATE+/- 33'-4 1/4"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 42'-8"NATURAL GRADE TO TOP OF PROPOSED PLATE+/- 21'-8 1/2"31.00.00.ANATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/2"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"44'-11"09.91.13.A09.91.13.A 09.91.13.A09.91.13.A 09.91.13.A09.91.13.A EF-2 EF-2EF-2 EF-2EF-2 EF-2 EF-2 EF-1 NATURAL GRADE TO TOP OF EXISTING PLATE+/- 11'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 18'-0 1/2"31.00.00.A 09.91.13.A09.91.13.A 09.91.13.A09.91.13.A 09.91.13.A09.91.13.A EF-2 EF-2 EF-1 EF-1 EF-1 EF-1 EF-2 EF-1 26.56.19.B26.56.19.B26.56.19.B26.56.19.B 26.56.19.B26.56.19.B26.56.19.B26.56.19.B 26.56.19.B26.56.19.B26.56.19.B26.56.19.B NATURAL GRADE TO TOP OF EXISTING PLATE+/- 12'-8"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 22'-10 1/2"31.00.00.A 4C A.403c 2C A.403c 09.91.13.A09.91.13.A EF-3 EF-1 EF-1 EF-1 EF-2 EF-1 EF-2 EF-1 EF-1 EF-1 EF-1 EF-4 EF-2EF-2EF-2 EF-2 EF-1 26.56.19.B TYP.NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 27'-2 1/2"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 43'-6"NATURAL GRADE TO TOP OF PROPOSED PLATE+/- 33'-4 1/4"31.00.00.A 44'-11"MTL-2 AT UNDERSIDE OF PORTE COCHERE & CANOPY D COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:53:24 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtEXTERIOR ELEVATIONS - COURTYARD 05/14/2019 - PERMIT SET A.202 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 3/32" = 1'-0" DRAWING REF: A.1116BELEVATION - WEST COURTYARD SCALE: 3/32" = 1'-0" DRAWING REF: A4233EELEVATION - SOUTH COURTYARD SCALE: 3/32" = 1'-0" DRAWING REF: A.1113CELEVATION - NORTH COURTYARD SCALE: 3/32" = 1'-0" DRAWING REF: A.1116AELEVATION - EAST COURTYARD KEYNOTES 09.91.13.A PAINT EXISTING TO REMAIN EIFS - REFER TO ELEVATIONS FOR COLORS. PAINT TRIMS, FASCIA, GUTTERS, RAIN LEADERS, HANDRAILS, GUARDRAIL, PTAC COVERS - MATCH ADJACENT EIFS WALL FINISH. 26.56.19.B OFCI EXTERIOR GRADE SCONE LIGHT. INSTALL IN EXISTING LIGHT LOCATION. REFER TO ELECTRICAL DRAWINGS FOR DETAILS 31.00.00.A NATURAL GRADE - AS PER GRADING PLAN DATED 10/25/86 BY SANDIS AND ASSOCIATES INC. ENGINEERS, SURVEYORS AND PLANNERS A 07/03/2019 PRELIMINARY REVIEW - REVISION C 11/20/2019 BUILDING PERMIT REVIEW - REVISION #3 D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 D D D D 02/21/2020 EF-1 EF-1 EF-1EF-1 EF-2 EF-1EF-1EF-1 EF-1EF-2 EF-2 EF-2 EF-2 EF-1 EF-2 EF-2EF-2EF-2 EF-2EF-2 EF-4 EF-4 EF-1 EF-1FC-1 EF-3 EF-2EF-2 EF-2 EF-2 EF-1 EF-2 EF-1EF-1 EF-2 EF-2 FC-1 EF-3 EF-2 EF-2 EF-2 EF-2 EF-3 FC-1 EF-1 EF-1 EF-1EF-1EF-1EF-1MTL-2 AT UNDERSIDE OF PORTE COCHERE & CANOPY D EF-2 @ TRASH ENCLOSURE WALLS, GATE, & ROOF STRUCTURE D EF-1 FC-1 EF-2 EF-2 EF-3 EF-3 EF-3 EF-1 EF-2 EF-1EF-1EF-1 EF-1 EF-2EF-1EF-2 EF-2 EF-1 TYP. EF-4 EF-4 MTL-2 AT UNDERSIDE OF PORTE COCHERE & CANOPY D EF-2 EF-2EF-2 EF-3 EF-2EF-2 FC-1 EF-3 EF-2 EF-2 EF-2 EF-2 EF-2 EF-2 EF-1 EF-1 EF-1 EF-1 EF-1EF-1 EF-2 EF-2 EF-2 EF-1 EF-1 EF-1 EF-1 EF-2 EF-1 EF-2 EF-2 EF-2 EF-2 EF-2EF-1 EF-2EF-4 EF-4 MTL-2 AT UNDERSIDE OF PORTE COCHERE & CANOPY D EF-2 TRASH ENCLOSURE EF-2 @ TRASH ENCLOSURE ROOF STRUCTURE D D ST-1 FC-1 EF-4 EF-3 EF-2 EF-1 COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:53:32 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtEXTERIOR ELEVATIONS, COLOR 05/14/2019 - PERMIT SET A.203 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 3/32" = 1'-0" DRAWING REF: A.1114EELEVATION - SOUTH - COLOR SCALE: 3/32" = 1'-0" DRAWING REF: A.1114CELEVATION - NORTH - COLOR SCALE: 3/32" = 1'-0" DRAWING REF: A4106AELEVATION - EAST - COLOR SCALE: 3/32" = 1'-0" DRAWING REF: A.1116BELEVATION - WEST - COLOR EXTERIOR COLOR FINISH LEGENDEXTERIOR FINISH LEGEND FINISH NO. MATERIAL MANUFACTURER STYLE NAME / NO. COLOR SIZE DESCRIPTION / REMARKS DRY STONE ST-01 DRY STONE HERITAGE STONE EIRE DRY STACK PROVIDE SAMPLE FOR FINAL APPROVAL BY ARCHITECT/MARRIOTT FIBER CEMENT WALL PANEL FC-1 FIBER CEMENT WALL PANEL NICHIHA VINTAGE WOOD CEDAR 18" x 10' x 5/8" W/ TAMLYN COORDINATED TRIM METAL CEILING PANEL MTL-2 METAL CEILING PANEL PAC-CLAD FLUSH SOLID WALL PANEL DARK BRONZE 12" CEILING OF PORTE COCHERE AND FRONT ENTRANCE CANOPY PAINT EF-1 PAINT SHERWIN WILLAIMS SNOWBOUND SW 7004 EF-2 PAINT BENJAMIN MOORE HEARTSONE SW 1601 EF-3 PAINT BENJAMIN MOORE GRAPHITE 1603 PT-3 PAINT SHERWIN WILLAIMS FIRETEX FX5090 TO MATCH PAC-CLAD DARK BRONZE EGGSHELL FOR (4) EXPOSED STEEL COLUMNS AND (2) EXPOSED BEAMS @ PORTE COCHERE PT-4 PAINT SHERWIN WILLAIMS PRO-INDUSTRIAL PRE-CATYLYZED WATER BASED EPOXY TRICORN BLACK SW 6258 EXTERIOR RAILINGS PT-5 PAINT SHERWIN WILLAIMS PRO-INDUSTRIAL PRE-CATYLYZED WATER BASED EPOXY TO MATCH POR-CLAD DARK BRONZE CANOPY SOFFIT EF-4 PAINT SHERWIN WILLIAMS PORTABELLO SW6102 A 07/03/2019 PRELIMINARY REVIEW - REVISION D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 D D D D 02/21/2020 EF-1 EF-4 EF-1 EF-2EF-2 EF-1 EF-2 EF-1 EF-2 EF-1 EF-1 EF-1 EF-3 EF-1EF-1 TYP. EF-2 EF-2EF-2 EF-2EF-2 EF-2 EF-2 EF-1 EF-2 EF-2 EF-1 EF-1 EF-1 EF-1 EF-2 EF-1 EF-3 EF-1 EF-1 EF-1 EF-2 EF-1 EF-2 EF-1 EF-1 EF-1 EF-1 EF-4 EF-2EF-2EF-2 EF-2 EF-1 TYP. MTL-2 AT UNDERSIDE OF PORTE COCHERE & CANOPY D ST-1 FC-1 EF-4 EF-3 EF-2 EF-1 COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:53:42 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtEXTERIOR ELEVATIONS - COURTYARD, COLOR 05/14/2019 - PERMIT SET A.204 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 3/32" = 1'-0" DRAWING REF: A.1116BELEVATION - EAST COURTYARD, COLOR SCALE: 3/32" = 1'-0" DRAWING REF: A4233EELEVATION - SOUTH COURTYARD, COLOR SCALE: 3/32" = 1'-0" DRAWING REF: A.1113CELEVATION - NORTH COURTYARD, COLOR SCALE: 3/32" = 1'-0" DRAWING REF: A.1116AELEVATION - WEST COURTYARD, COLOR EXTERIOR COLOR FINISH LEGENDEXTERIOR FINISH LEGEND FINISH NO. MATERIAL MANUFACTURER STYLE NAME / NO. COLOR SIZE DESCRIPTION / REMARKS DRY STONE ST-01 DRY STONE HERITAGE STONE EIRE DRY STACK PROVIDE SAMPLE FOR FINAL APPROVAL BY ARCHITECT/MARRIOTT FIBER CEMENT WALL PANEL FC-1 FIBER CEMENT WALL PANEL NICHIHA VINTAGE WOOD CEDAR 18" x 10' x 5/8" W/ TAMLYN COORDINATED TRIM METAL CEILING PANEL MTL-2 METAL CEILING PANEL PAC-CLAD FLUSH SOLID WALL PANEL DARK BRONZE 12" CEILING OF PORTE COCHERE AND FRONT ENTRANCE CANOPY PAINT EF-1 PAINT SHERWIN WILLAIMS SNOWBOUND SW 7004 EF-2 PAINT BENJAMIN MOORE HEARTSONE SW 1601 EF-3 PAINT BENJAMIN MOORE GRAPHITE 1603 PT-3 PAINT SHERWIN WILLAIMS FIRETEX FX5090 TO MATCH PAC-CLAD DARK BRONZE EGGSHELL FOR (4) EXPOSED STEEL COLUMNS AND (2) EXPOSED BEAMS @ PORTE COCHERE PT-4 PAINT SHERWIN WILLAIMS PRO-INDUSTRIAL PRE-CATYLYZED WATER BASED EPOXY TRICORN BLACK SW 6258 EXTERIOR RAILINGS PT-5 PAINT SHERWIN WILLAIMS PRO-INDUSTRIAL PRE-CATYLYZED WATER BASED EPOXY TO MATCH POR-CLAD DARK BRONZE CANOPY SOFFIT EF-4 PAINT SHERWIN WILLIAMS PORTABELLO SW6102 A 07/03/2019 PRELIMINARY REVIEW - REVISION C 11/20/2019 BUILDING PERMIT REVIEW - REVISION #3 D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 D D D D 02/21/2020 6B D.301 02.41.19.63 02.41.19.52 02.41.19.52 02.41.19.63 02.41.19.6902.41.19.69 02.41.19.6902.41.19.69 02.41.19.6902.41.19.69 02.41.19.6902.41.19.69 02.41.19.53 02.41.19.6902.41.19.69 02.41.19.53 NATURAL GRADE TO TOP OF EXISTING PLATE+/- 12'-10 3/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 19'-3 3/4"31.00.00.A EF-1 EF-1 EF-1EF-1 EF-2 EF-1EF-1EF-1 EF-1EF-2 EF-2 EF-2 EF-2 EF-1 EF-2 EF-2EF-2EF-2 EF-2EF-2 EF-4 EF-4 EF-2 EF-2EF-2 EF-3 EF-2EF-2 FC-1 EF-3 EF-2 EF-2 EF-2 EF-2 EF-2 EF-2 EF-1 EF-1 EF-1 EF-1 EF-1EF-1 EF-2 EF-2 EF-2 EF-1 EF-1 EF-1 EF-1 EF-2 EF-1 EF-2 EF-2 EF-2 EF-2 EF-2EF-1 EF-2EF-4 EF-4 MTL-2 AT UNDERSIDE OF PORTE COCHERE & CANOPY D EF-2 TRASH ENCLOSURE D EF-2 @ TRASH ENCLOSURE ROOF STRUCTURE D 3B D.301 2B D.301 02.41.19.67 02.41.19.51 02.41.19.53 02.41.19.51 02.41.19.50 02.41.16.01 02.41.19.69 02.41.19.52 02.41.19.69 02.41.19.69 26.56.19.B02.41.19.65 02.41.19.63 02.41.19.69 02.41.19.69 02.41.19.69 02.41.19.6502.41.19.6502.41.19.6502.41.19.65 TYP. 02.41.19.6902.41.19.69 NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 42'-8"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/2"NATURAL GRADE TO TOP OF ROOF RIDGE TO BE DEMOLISHED+/- 32'-3 1/2"NATURAL GRADE TO TOP OF EXISTING / TO BE DEMOLSIHED PLATE+/- 27'-2 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 11'-10 3/4"NATURAL GRADE TO TOP OF PORTE COCHERE ROOF RIDGE TO BE DEMOLISHED+/- 18'-4 3/4"31.00.00.A COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:53:48 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtELEVATIONS - EXISTING & PROPOSED 05/14/2019 - PERMIT SET A.211 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA A 07/03/2019 PRELIMINARY REVIEW - REVISION C 11/20/2019 BUILDING PERMIT REVIEW - REVISION #3 D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 SCALE: 3/32" = 1'-0" DRAWING REF: xG0021DEMOLITION ELEVATION - SOUTH SCALE: 3/32" = 1'-0" DRAWING REF: xG0022ELEVATION SOUTH, COLOR SCALE: 3/32" = 1'-0" DRAWING REF: A.4063ELEVATION - WEST, COLOR SCALE: 3/32" = 1'-0" DRAWING REF: A.4064DEMOLITION ELEVATION - WEST D D D D 02/21/2020 EF-1 EF-1FC-1 EF-3 EF-2EF-2 EF-2 EF-2 EF-1 EF-2 EF-1EF-1 EF-2 EF-2 FC-1 EF-3 EF-2 EF-2 EF-2 EF-2 EF-3 FC-1 EF-1 EF-1 EF-1EF-1EF-1EF-1MTL-2 AT UNDERSIDE OF PORTE COCHERE & CANOPY D EF-2 @ TRASH ENCLOSURE WALLS, GATE, & ROOF STRUCTURE D 2A D.301 4A D.301 02.41.19.67 02.41.19.52 02.41.19.51 02.41.19.69 02.41.19.69 02.41.19.51 02.41.16.01 02.41.19.56 02.41.19.52 02.41.19.66 02.41.19.68 02.41.19.67 02.41.19.51 02.41.19.53 02.41.19.6902.41.19.69 02.41.19.69 02.41.19.6902.41.19.69 02.41.19.52 NATURAL GRADE TO TOP OF PLATE OF PORTE COCHERE TO BE DEMOLISHED+/- 11'-10 3/4"NATURAL GRADE TO TOP OF PORTE COCHERE ROOF RIDGE TO BE DEMOLISHED+/- 18'-5 1/4"NATURAL GRADE TO TOP OF EXISTINGPLATE TO BE DEMOLISHED+/- 13'-10 3/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE TO BE BUILD OVER+/- 23'-10 3/4"31.00.00.A 02.41.19.63 02.41.19.65 02.41.19.69 02.41.19.52 02.41.19.67 02.41.19.51 02.41.19.53 02.41.19.69 02.41.19.51 02.41.16.01 02.41.19.50 02.41.19.69 02.41.19.69 02.41.19.69 02.41.19.65 02.41.19.71 TYP. 02.41.19.6902.41.19.69 NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 45'-6"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 31'-8 1/2"NATURAL GRADE TO TOP OF PLATE TO BE DEMOLISHED+/- 29'-2 1/2"NATURAL GRADE TO TOP OF PLATE TO BE DEMOLISHED+/- 12'-10 3/4"NATURAL GRADE TO TOP OF PORTE COCHERE ROOF RIDGE TO BE DEMOLISHED+/- 19'-4 3/4"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 33'-1 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 47'-6 1/2"31.00.00.A EF-1 FC-1 EF-2 EF-2 EF-3 EF-3 EF-3 EF-1 EF-2 EF-1EF-1EF-1 EF-1 EF-2EF-1EF-2 EF-2 EF-1 TYP. EF-4 EF-4 MTL-2 AT UNDERSIDE OF PORTE COCHERE & CANOPY D COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:54:02 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtELEVATIONS - EXISTING & PROPOSED 05/14/2019 - PERMIT SET A.212 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA A 07/03/2019 PRELIMINARY REVIEW - REVISION C 11/20/2019 BUILDING PERMIT REVIEW - REVISION #3 D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 SCALE: 3/32" = 1'-0" DRAWING REF: A.401a1ELEVATION - NORTH, COLOR SCALE: 3/32" = 1'-0" DRAWING REF: A.401a2DEMOLITION ELEVATION - NORTH SCALE: 3/32" = 1'-0" DRAWING REF: A4103DEMOLITION ELEVATION - EAST SCALE: 3/32" = 1'-0" DRAWING REF: A4104ELEVATION - EAST, COLOR D D D D 02/21/2020 02.41.19.69 02.41.19.69 02.41.19.6902.41.19.69 02.41.19.69 02.41.19.69 NATURAL GRADE TO TOP OF EXISTING PLATE+/- 11'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 18'-0 1/2"EF-2 EF-2EF-2 EF-2EF-2 EF-2 EF-2 EF-1 02.41.19.63 02.41.19.6902.41.19.69 02.41.19.6902.41.19.69 02.41.19.65 02.41.19.52 02.41.19.67 02.41.19.51 02.41.19.50 02.41.16.01 02.41.19.51 02.41.19.6502.41.19.65 02.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.65 02.41.19.6502.41.19.65 02.41.19.6502.41.19.6502.41.19.65 02.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.65 02.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.65 02.41.19.6502.41.19.6502.41.19.65 02.41.19.5202.41.19.52 TYP.TYP.TYP. 02.41.19.69 31.00.00.ANATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/2"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 42'-8"EF-1 EF-4 EF-1 EF-2EF-2 EF-1 EF-2 EF-1 EF-2 EF-1 EF-1 EF-1 EF-3 EF-1EF-1 TYP. COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:54:10 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtELEVATIONS - EXISTING & PROPOSED 05/14/2019 - PERMIT SET A.213 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA A 07/03/2019 PRELIMINARY REVIEW - REVISION C 11/20/2019 BUILDING PERMIT REVIEW - REVISION #3 D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 SCALE: 3/32" = 1'-0" DRAWING REF: A4231DEMOLITION ELEVATION - SOUTH COURTYARD SCALE: 3/32" = 1'-0" DRAWING REF: A4232ELEVATION - SOUTH COURTYARD, COLOR SCALE: 3/32" = 1'-0" DRAWING REF: A0063DEMOLITION ELEVATION - WEST COURTYARD SCALE: 3/32" = 1'-0" DRAWING REF: A.402a4ELEVATION - WEST COURTYARD, COLOR D D D D 02/21/2020 02.41.19.6902.41.19.69 02.41.19.6902.41.19.6902.41.19.6902.41.19.69 02.41.19.65 02.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.6902.41.19.69 TYP.NATURAL GRADE TO TOP OF EXISTING PLATE+/- 12'-8"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 22'-10 1/2"EF-2 EF-2 EF-1 EF-1 EF-1 EF-1 EF-2 EF-1 5B D.301 02.41.16.01 02.41.19.50 02.41.19.51 02.41.19.53 02.41.19.66 02.41.19.51 02.41.19.67 02.41.19.6902.41.19.69 02.41.19.6902.41.19.69 02.41.19.63 02.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.6502.41.19.6502.41.19.65 TYP. TYP. 02.41.19.69 02.41.19.5202.41.19.52 NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 27'-2 1/2"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 43'-6"EF-3 EF-1 EF-1 EF-1 EF-2 EF-1 EF-2 EF-1 EF-1 EF-1 EF-1 EF-4 EF-2EF-2EF-2 EF-2 EF-1 TYP. MTL-2 AT UNDERSIDE OF PORTE COCHERE & CANOPY D COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:54:18 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtELEVATIONS - EXISTING & PROPOSED 05/14/2019 - PERMIT SET A.214 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA A 07/03/2019 PRELIMINARY REVIEW - REVISION C 11/20/2019 BUILDING PERMIT REVIEW - REVISION #3 D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 SCALE: 3/32" = 1'-0" DRAWING REF: D.1111DEMOLITION ELEVATION - NORTH COURTYARD SCALE: 3/32" = 1'-0" DRAWING REF: xG0022ELEVATION - NORTH COURTYARD, COLOR SCALE: 3/32" = 1'-0" DRAWING REF: A.401a3DEMOLITION ELEVATION - EAST COURTYARD SCALE: 3/32" = 1'-0" DRAWING REF: A.401a4ELEVATION - EAST COURTYARD, COLOR D D D D 02/21/2020 5A A.401b 3A A.401b 2'-4"24'-7"2'-4" 29'-3"7'-11"1'-8"2'-4"21'-8"2'-4"5C A.402b SIM A.401b 5C EQ EQ EQ EQ EQEQEQEQ26'-4"3A A.401c 2A A.401c 5A A.401c EQ EQALIGN PORTE COCHERE EDGE OF ROOF ABOVE EDGE OF SOFFIT ABOVE PORTE COCHERE EDGE OF ROOF ABOVE CONCRETE PLANTER, REFERENCE STRUCTURAL DRAWINGS NEW PORTE COCHERE PAVEMENT NEW CONCRETE PAD, SUNDEK-CLASSIC TEXTURE DECORATIVE CONCRETE APPLICATION w/ CUSTOM 1'-0" LINEAR BANDS. COLOR: PEWTER GRAY, SLOPE NOT TO EXCEED 1:50 IN ALL DIRECTIONS NEW SIDEWALK AND CURB PORTE COCHERE EDGE OF ROOF ABOVE EDGE OF LOW ROOF ABOVE 6C A.401a 6A A.401c A.401a 4C 5A A.401b 5C A.402b 3'-9"11'-1 1/4"12'-1 1/4"16'-11 1/4" 3A A.401b 26'-11 1/2"EQ.EQ.EQ.6'-0"6'-0"6'-0"EQ.EQ.8'-4"EQ.EQ.6'-4"EQ.1'-11"7'-0" 4'-7"26'-11"3'-11 3/4" 35'-6"1'-5 3/4"24'-0"1'-5 3/4"11 3/4"9'-1 1/4"1'-8"5'-2 1/4"EQEQ(TYP 10 AT PORTE COCHERE) 26.56.20 C PT-05 C PT-05 26.56.20 (TYP 4 AT VESTIBULE) 5C A.401c SIM 6C A.401c 5A A.401b 3A A.401b SLOPE 1/4":1'-0" MINSLOPE 1/4":1'-0" MINA.401b 5C 6C A.401c 4" THICK 3,000 PSI CONCRETE PAVING, W/ 6X6X10/10 WELDED WIRE FABRIC TYP. COMPACTED SUBGRADE EXISTING ASPHALT PAVING ALIGN SUNDEK-CLASSIC TEXTURE DECORATIVE CONCRETE APPLICATION w/ CUSTOM 1'-0" LINEAR BANDSCOLOR: PEWTER GRAY 4" THICK 3,000 PSI CONCRETE PAVING, W/ 6X6X10/10 WELDED WIRE FABRIC TYP. COMPACTED SUBGRADE EXISTING ASPHALT PAVING ALIGN SUNDEK-CLASSIC TEXTURE DECORATIVE CONCRETE APPLICATION w/ CUSTOM 1'-0" LINEAR BANDS. COLOR: PEWTER GRAY SLOPE NOT TO EXCEED 1:50 IN ALL DIRECTIONS SQUARE CAST IRON ROOF DRAIN AND OVERFLOW DRAIN, SECURE TO STRUCTURAL COLUMN, PAINT WITH INTUMESCENT PAINT, PT-3 EXPOSED STRUCTURAL STEEL, REFERENCE STRUCTURAL DRAWINGS, PAINT WITH INTUMESCENT PAINT, PT-3 COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 12:14:51 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtENLARGED PORTE COCHERE PLANS, REFLECTED CEILING PLANS & ROOF PLANS 05/14/2019 - PERMIT SET A.401a 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA KEYNOTES 26.56.20 NEW EXTERIOR RECESSED LIGHT. REFERENCE ELECTRICAL DRAWINGS. SCALE: 1/4" = 1'-0" DRAWING REF: A.1113AENLARGED PLAN - PORTE COCHERE SCALE: 1/4" = 1'-0" DRAWING REF: A.401b3CENLARGED REFLECTED CEILING PLAN - PORTE COCHERE SCALE: 1/4" = 1'-0" DRAWING REF: A.1145AENLARGED ROOF PLAN - PORTE COCHERE SCALE:6E PERSPECTIVE SCALE: 1 1/2" = 1'-0" DRAWING REF: A.401a6CDETAIL - PORTE COCHERE PAVEMENT SCALE: 3" = 1'-0" DRAWING REF: A.401a4CDETAIL - PLAN - PORTE COCHERE 05/14/2019 1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7"1'-6"11'-4"A.401c 3C A.401c 4C 1st Floor 0' -0" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" 1st Floor 0' -0" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" A.401c 2C GROUND SLOPE MAY VARY CONCRETE PLANTER, REFERENCE STRUCTURAL DRAWINGS GROUND SLOPE MAY VARY 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" A.402c 5E SIM A.402c 3C SIM 12'-10"3'-6"19'-0"22'-6"1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 1st Floor 0' -0" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" 1st Floor 0' -0" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1 /4 " / 1 '-0 " M I N 22.14.28.A +/- 9'-0"CL 1/4" / 1'-0" MIN 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0"1'-6"11'-4"2'-2 1/4"9'-1 3/4"3A A.401b 3A A.401c 2A A.401c 1'-6"11'-4"2'-2 1/4"9'-1 3/4"1/8"9'-1 5/8"COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 12:14:54 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtENLARGED PORTE COCHERE SECTIONS AND ELEVATIONS 05/14/2019 - PERMIT SET A.401b 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA KEYNOTES 22.14.28.A PRIMARY ROOF DRAIN. CONCEAL PRIMARY ROOF DRAIN IN ROOF ASSEMBLY. CONNECT TO UNDERGROUND STORM/SEVER RUNOFF SYSTEM. WHEN POSSIBLE LOCATE TO EXISTING LOCATION FROM DEMOLISHED DOWNSPOUT SCALE: 1/4" = 1'-0" DRAWING REF: A.401a3APORTE COCHERE - SECTION SCALE: 1/4" = 1'-0" DRAWING REF: A.401a5APORTE COCHERE - SECTION SCALE: 1/4" = 1'-0" DRAWING REF: A.402a3CPORTE COCHERE - SIDE ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A.401a5CPORTE COCHERE - FRONT ELEVATION SCALE: 1/4" = 1'-0"3D PORTE COCHERE - SIDE ELEVATION@ 05/14/2019 BACKER ROD AND CONTINUOUS SEALANT, PER PANEL REQ. METAL PANEL SYSTEM ON CARRIER DRIP EDGE PT WD BLOCKING METAL WRAP DARK BRONZE FINISH 5/8" DENSGLASS SHEATHING MEMB FLASH COATED MET DRIP EDGE FASTNER 4" OC STAGGERED CONT 2x6 PT WD NAILER SHIM AS REQ RIGID INSULATION - 1 1/2" MIN. MEMB. ROOFING - EXTEND OVER EDGE OF BUILDING VARIES1'-2 3/8"6" MIN.TAPERED RIGID INSULATION - 1.5" MIN FULLY ADHERED, CONTINUOUS TPO ROOF MEMBRANE FIBER CEMENT PANEL ON PROPRIETARY CLIP SYSTEM 1" POLYMER-BASED EXTERIOR INSULATION. INSULATION COMPRESSIVE STRENGTHS OF 25 PSI MIN. NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 5/8" DENSGLASS SHEATHING 3/4" PLYWOOD SHEATHING UNFACED BATH INSULATION R-19 MIN EXISTING VESTIBULE WALLS & SOFFIT - EXTEND TO UNDERSIDE OF DECK REPAIR EXISTING FINISHES AS REQUIRED. METAL PANEL SYSTEM ON CARRIER EXISTING TO REMAIN STOREFRONT BACKER ROD AND CONTINUOUS SEALANT, PER PANEL REQ. PROVIDE BUG SCREEN AT EXPOSED ENDS OF FIBER CEMENT PANEL WALLS EXISTING WALL TO REMAIN. REMOVE SHEATHING AND EIFS FINISH AND PREPARE TO RECEIVE NEW REINFORCED PARAMITER SECUREMNT DETAIL 1" POLYISO INSULATION EXPOSED STRUCTURAL STEEL, REFERENCE STRUCTURAL DRAWINGS, PAINT WITH INTUMESCENT PAINT, PT-3 METAL PANEL SYSTEM ON CARRIER TPO ROOF MEMBRANE, EXTEND ON TOP OF CHANNEL PLYWOOD DECKING, REFERENCE STRUCTURAL DRAWINGS STRUCTURAL WOOD AND JOISTS, REFRENCE STRUCTURAL DRAWINGS BACKER ROD AND CONTINUOUS SEALANT, PER PANEL REQ. TAPERED RIGID INSULATION VARIESMEMB FLASH COATED MET DRIP EDGE. COLOR TO MATCH PAINT PT-3 5A A.401c WATERPROOFING MEMBRANE UNDER TOP CAP PRECAST CONCRETE CAP, STAINED TO MATCH DRY STONE DRY STONE: 4" DRY STACKED STONE VENEER, PROVIA, DRY STACK COLOR EIRIE EMBED STEEL COLUMN IN CONCRETE BASE CONCEAL DRAIN PIPE IN CONCRETE BASE. EXPANSION JOINT WHERE PAVING MEETS BASE CAST IRON, SQUARE DRAIN PIPE. FINISH TO MATCH ADJACENT STEEL STRUCTURE 2"REFER TO STRUCTURAL DRAWINGS 1 3/4"2'-0 1/2"1 3/4" 2'-4"1'-10"2'-0"REFER TO STRUCTURAL DRAWINGSCOATED MET DRIP EDGE MEMB FLASH FASTNER 4" OC STAGGERED CONT 2x6 PT WD NAILER SHIM AS REQ MEMB. ROOFING - EXTEND OVER EDGE OF BUILDING RIGID INSULATION - 1 1/2" MIN. BACKER ROD AND CONTINUOUS SEALANT, PER PANEL REQ. METAL PANEL SYSTEM ON CARRIER STRUCTURE - REFER TO STRUCTURAL DRAWINGS METAL WRAP DARK BRONZE FINISH 5/8" DENSGLASS SHEATHING DRIP EDGE PT WD BLOCKING CONTINUES CLEAT 3A A.401c 2A A.401c LANDSCAPE FABRIC WITH COARSE GRAVEL BELOW PLANTING MIX DRY STONE: 4" DRY STACKED STONE VENEER, PROVIA, DRY STACK COLOR EIRIE PRECAST CONCRETE CAP, STAINED TO MATCH DRY STONE MORTAR BED, TYP. SLOPE TO DRAIN. WEEP HOLES, 24" O.C. WATERPROOF ALL INSIDE FACE OF CONCRETE CL REFERENCE STRUCTURAL DRAWINGS FOR CONCRETE CONSTRUCTION DETAILS REFERENCE STRUCTURAL DRAWINGS FOR REBAR LOCATION AND INFORMATION WATERPROOFING MEMBRANE UNDER TOP CAP PRECAST CONCRETE CAP, STAINED TO MATCH DRY STONE DRY STONE: 4" DRY STACKED STONE VENEER, PROVIA, DRY STACK COLOR EIRIE EMBED STEEL COLUMN IN CONCRETE BASE CONCEAL DRAIN PIPE IN CONCRETE BASE. EXPANSION JOINT WHERE PAVING MEETS COLUMN BASE CAST IRON, SQUARE DRAIN PIPE. FINISH TO MATCH ADJACENT STEEL STRUCTURE 3'-1"REFER TO STRUCTURAL DRAWINGSLANDSCAPE FABRIC WITH COARSE GRAVEL BELOW PLANTING MIX DRY STONE: 4" DRY STACKED STONE VENEER, PROVIA, DRY STACK COLOR EIRIE PRECAST CONCRETE CAP, STAINED TO MATCH DRY STONE CL MORTAR BED, TYP. SLOPE TO DRAIN. WEEP HOLES, 24" O.C. EXPANSION JOINT WHERE PAVING MEETS BASE WATERPROOF ALL INSIDE FACE OF CONCRETE CL STRUCTURAL STEEL BEYOND REFERENCE STRUCTURAL DRAWINGS FOR CONCRETE CONSTRUCTION DETAILS REFERENCE STRUCTURAL DRAWINGS FOR CONCRETE CONSTRUCTION DETAILS REFERENCE STRUCTURAL DRAWINGS FOR REBAR LOCATION AND INFORMATION 2'-9" 8" 4 3/4"3 1/4" 1 1/2"1 1/2"2'-6" 8" 3 1/4"4 3/4" LANDSCAPINGREFERENCE STRUCTURAL DRAWINGS FOR INFORMATION EXPANSION JOINT WHERE PAVING MEETS COLUMN BASE STEEL COLUMN - REFER TO STRUCTURAL DRAWINGS NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM 5/8" DENSGLASS SHEATHING PT WOOD 1ST FLOOR 0' -0" 1/4" GALV ST GUTTER BRACKETS @ 3'-0" OC (PAINT TO MATCH) MIDPOINT BETWEEN GUTTER STRAPS 1/8" GALV ST GUTTER BRACKETS @ 3'-0" OC (PAINT TO MATCH) MIDPOINT BETWEEN GUTTER STRAPS 4" x 4" PRE-FIN MET GUTER METAL WRAP DARK BRONZE FINISH 5/8" DENSGLASS SHEATHING STEEL COLUMN - REFER TO STRUCTURAL DRAWINGS COATED MET DRIP EDGE MEMB FLASH FASTNER 4" OC STAGGERED DRIP EDGE NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM 5/8" DENSGLASS SHEATHING CONT 2x6 PT WD NAILER SHIM AS REQ MEMB. ROOFING - EXTEND OVER EDGE OF BUILDING BACKER ROD AND CONTINUOUS SEALANT, PER PANEL REQ. METAL PANEL SYSTEM ON CARRIER RIGID INSULATION - 1 1/2" MIN. COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 12:14:58 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtDETAILS - PORTE COCHERE 05/14/2019 - PERMIT SET A.401c 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 1 1/2" = 1'-0" DRAWING REF: A.401b4CPORTE COCHERE - LOWER ROOF SCALE: 1 1/2" = 1'-0" DRAWING REF: A.401b3CPORTE COCHERE - LOWER ROOF @ VESTIBULE SCALE: 1 1/2" = 1'-0" DRAWING REF: A.401b2CDETAIL - SECTION - PORTE COCHERE ROOF SCALE: 1 1/2" = 1'-0" DRAWING REF: A.401a3ADETAIL - SECTION COLUMN SCALE: 1 1/2" = 1'-0" DRAWING REF: A.401a5CPORTE COCHERE - LOWER ROOF SCALE: 1 1/2" = 1'-0" DRAWING REF: A.401a5ADETAIL - SECTION - COLUMN AT PLANTER SCALE: 1 1/2" = 1'-0" DRAWING REF: A.401a2ADETAIL - SECTION PLANTER SCALE: 1 1/2" = 1'-0" DRAWING REF: A.401a6ADETAIL - SECTION - LOW ROOF COLUMN BASE SCALE: 1 1/2" = 1'-0" DRAWING REF: A.401a6CPORTE COCHERE - LOWER ROOF @ COLUMN KEYNOTES 05/14/2019 J J J J 1A A.402b 6A A.402b 3C A.402b 3A A.402b 5C A.402b 4A A.402b A.402c 6A A.402c 6A A.402c 6C 1'-8 1/4"+/- 26'-11 1/2"1'-0 5/8"7'-4"1'-8"7'-4"1'-8"7'-4"6 7/8"1'-3 1/4"07.24.13.A 06.10.00.E 08.41.13.A 07.24.13.A 07.24.13.A ST-01 08.41.13.A ST-01 08.41.13.A ST-01 TYP. TYP. A.402c 6B A.402c 5B 32.92.0032.92.00 03.30.00 07.24.13.A 03.30.00 07.24.13.A 03.30.00 08.41.13.A ST-02 ST-02 1'-3 1/4"1'-8" 1'-8" 32.92.0032.92.00 07.24.13.A TYP. 6A A.401c 5C A.402b 4A A.402b ALL NEW ROOF SLOPES 1/4":1'-0" MIN. TYPALL NEW ROOF SLOPES 1/4":1'-0" MIN. TYP22.14.28.B 07.21.00.E07.21.00.E 07.21.00.E07.21.00.E 07.21.00.E 07.32.13.A 07.72.00.A 5C A.401c 6C A.401c 22.14.28.A 22.14.28.B 22.14.28.A 5C A.402b 4A A.402b A.402c 6A 07.42.50 10.14.00 07.24.13.A 07.24.13.A 07.24.13.A 07.24.13.A 07.24.13.A 6C A.401c C EF-1 9' -0" A.F.F. C EF-1 9' -0" A.F.F. C 401 7' -11 3/4" A.F.F. C 401 7' -11 3/4" A.F.F. C 401 7' -11 3/4" A.F.F. C 401 C 401 C 401 7' -11 3/4" A.F.F. C 401 7' -11 3/4" A.F.F. C 401 7' -11 3/4" A.F.F. C 401 7' -11 3/4" A.F.F. C 401 7' -11 3/4" A.F.F. C 401 7' -11 3/4" A.F.F. C 401 09.29.00.A09.29.00.A 09.91.23.H 09.91.23.H 09.91.23.H 09.91.23.H 09.91.23.H 07.24.13.A 07.24.13.A NOT ACCESSIBLE SPACE 26.56.20 C EF-3 COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 12:15:06 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtENLARGED PLANS - MAIN ENTRANCE 05/14/2019 - PERMIT SET A.402a 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 1/4" = 1'-0"1A ENLARGED PLAN - MAIN ENTRANCE SCALE: 1/4" = 1'-0" DRAWING REF: A.1146AENLARGED ROOF PLAN - MAIN ENTRANCE SCALE:6E PERSPECTIVE SCALE: 1/4" = 1'-0" DRAWING REF: A.1114A ENLARGED PLAN MAIN ENTRANCE UPPER LEVEL SCALE: 1/4" = 1'-0"2A ENLARGED PLAN MAIN ENTRANCE REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0"5A ENLARGED PLAN MAIN ENTRANCE UPPER LEVEL REFLECTED CEILING PLAN KEYNOTES 03.30.00 CAST-IN-PLACE CONCRETE FLOOR SLAB. SEE STRUCTURAL DRAWINGS. 06.10.00.E STRONG WALL REFER TO STRUCTURAL DRAWINGS FOR DETAILS 07.21.00.E BUILD UP CRICKET WITH RIGID INSULATION. 07.24.13.A EIFS COATINGS - REFER TO ELEVATIONS FOR COLOR 07.32.13.A REUSE CERAMIC TILE SAVED FROM DEMOLITION OR PROVIDE NEW TO MATCH EXISTING 07.42.50 NICHINA FIBER CEMENT PANEL SYSTEM. 07.72.00.A PREMANUFACTURED COPING - METAL ERA PERMA TILE CONTINUES CLEAT 08.41.13.A 09.29.00.A PROVIDE NEW SOFFIT. MATCH ADJACENT SOFFIT ELEVATION AND TEXTURE. 09.91.23.H PREP AND PAINT SOFFIT 10.14.00 OFCI SIGNAGE. PROVIDE BLOCKING AND POWER TO SIGNAGE PER ELECTRICAL DRAWINGS. 22.14.28.A PRIMARY ROOF DRAIN. CONCEAL PRIMARY ROOF DRAIN IN ROOF ASSEMBLY. CONNECT TO UNDERGROUND STORM/SEVER RUNOFF SYSTEM. WHEN POSSIBLE LOCATE TO EXISTING LOCATION FROM DEMOLISHED DOWNSPOUT 22.14.28.B OVERFLOW ROOF DRAIN. 26.56.20 NEW EXTERIOR RECESSED LIGHT. REFERENCE ELECTRICAL DRAWINGS. 32.92.00 ADD LANDSCAPE 05/14/2019 1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 1st Floor 0' -0" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" 1st Floor 0' -0" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" A.402c 3A3'-6"10'-0"9'-0"22'-6"3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" A.402c 5E SIM +/- 14'-5 5/8"A.402c 4D SIM 1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 1st Floor 0' -0" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" 1st Floor 0' -0" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" +/- 14'-5 5/8"3'-6"9'-9"9'-3"22'-6"A.402c 5E SIM A.402c 4D SIM 1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 1st Floor 0' -0" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" 1st Floor 0' -0" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" EF-3 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" A.402c 5E SIM 3'-6"10'-0"9'-0"A.402c 4D SIM 1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 1st Floor 0' -0" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" 1st Floor 0' -0" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" A.402c 5E SIM 3'-6"10'-0"9'-0"+/- 14'-5 5/8"22'-6"A.402c 4D SIM 1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 1A A.402b 6A A.402b 3C A.402b 3A A.402b 4A A.402b A.402c 6D FC-1 A.402c 5E A.402c 4D 1st Floor 0' -0" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" 1st Floor 0' -0" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" A.402c 3C A.402c 4A 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0"3'-6"10'-0"9'-0"+/- 14'-5 5/8"22'-6"E.Q.E.Q.E.Q.E.Q.E.Q.E.Q.E.Q.E.Q.E.Q.E.Q.22'-6"07.42.50.A 07.24.13.B EF-3 FC-1 EF-1 EF-1EF-1EF-1 ? EF-1EF-1 EF-3EF-2 EF-2 ALIGN EF-1 EF-1 EF-1 EF-1 EF-1 EF-3 EF-3 NO WORK IN THIS AREA POCHE LEGEND COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 12:15:11 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtENLARGED SECTIONS - MAIN ENTRANCE 05/14/2019 - PERMIT SET A.402b 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 1/4" = 1'-0" DRAWING REF: A.2011AMAIN ENTRANCE - SECTION SCALE: 1/4" = 1'-0" DRAWING REF: A.2016AMAIN ENTRANCE - SECTION SCALE: 1/4" = 1'-0" DRAWING REF: A.2013CMAIN ENTRANCE - SECTION SCALE: 1/4" = 1'-0" DRAWING REF: A.2013AMAIN ENTRANCE - SECTION SCALE: 1/4" = 1'-0" DRAWING REF: A.401a5CMAIN ENTRANCE - SECTION SCALE: 1/4" = 1'-0" DRAWING REF: A.2014AMAIN ENTRANCE - SECTION KEYNOTES 07.24.13.B REVEAL IN EIFS COATINGS 07.42.50.A CONTROL JOINT SCALE: 1/4" = 1'-0"5D MAIN ENTRANCE - FRONT ELEVATION SCALE: 1/4" = 1'-0"3D MAIN ENTRANCE - SIDE ELEVATION 05/14/2019 EXISTING EXTERIOR WALL. PREPARE ETR EIFS AS REQUIRED TO RECEIVE NEW PAINT EXISTING EXTERIOR WALL FRAMING AND INSULATION. REMOVE EIFS AND SHEETING TO THE EXTEND SHOWN 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER FOR SHEATHING, FRAMING & FOUNDATION REFER TO STRUCTURAL DRAWINGS CONCEAL STORM PIPE WITHIN NEW STRUCTURE EXISTING EXTERIOR WALL. PREPARE ETR EIFS AS REQUIRED TO RECEIVE NEW PAINT BACKER ROD AND CONTINUES SEALANT NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM 5/8" DENSGLASS SHEATHING 1/2" RESILIANT CHANNEL SOFFIT VENT SOFFIT DRIP EDGE 2X WD FRAMING REFER TO STRUCTURAL DRAWINGS NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM 5/8" DENSGLASS SHEATHING UNFACED BATT INSULATION PREMANUFACTURED COPING - METAL ERA PERMA TITE CONTINUOUS CLEAT COPING BUTYL SEALING TAPE FULLY ADHERED, CONTINUOUS TPO ROOF MEMBRANE, EXTEND OVER PARAPET AND SECURE TO OUTSIDE FACE OF SHEATHING TAPERED RIGID INSULATION 3/4" PLYWOOD PLYWOOD SHEATHING TURN FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER ON TOP OF WALL ADHERE ROOF MEMBRANE TO IT NEW 2X WD FRAMING, REFERENCE STRUCTURAL DRAWINGS NEW CEMENT PANELS ON PROPRIETARY CLIP SYSTEM EXTERIOR RECESSED LIGHT FIXTURE, REFERENCE ELECTRICAL DRAWINGS FOR MORE INFORMATION CL FULLY ADHERED, CONTINUOUS TPO ROOF MEMBRANE, EXTEND OVER PARAPET AND SECURE TO OUTSIDE FACE OF SHEATHING TAPERED RIGID INSULATION 3/4" PLYWOOD NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM 5/8" DENSGLASS SHEATHING 1/2" RESILIANT CHANNEL UNFACED BATT INSULATION 1" POLYMER-BASED EXTERIOR INSULATION. INSULATION COMPRESIVE STRENGHT OF 25 PSI MIN. NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER NEW SHEATHING NEW OR EXISTING 2X WD FRAMING, REFERENCE STRUCTURAL DRAWINGS EXISTING TO REMAIN OR PROVIDE NEW UNFACED BATT INSULATION. GC TO VIF. 5 1/2"BACKER ROD AND CONTINUES SEALANT TURN FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER ON TOP OF WALL ADHERE ROOF MEMBRANE TO IT TAPERED CRICKET PREMANUFACTURED COPING - METAL ERA PERMA TITE CONTINUOUS CLEAT COPING REF ROOF PLAN FOR CRICKET SIZE EXTENT OF ROOFING MEMBRANE PRE-FINISHED THRU WALL FLASHING REMOVABLE COUNTERFLASHING BUTYL SEALING TAPE REUSE ROOF TILE SAVED FROM DEMOLITION OR PROVIDE NEW TO MATCH EXISTING 5/8" DENSGLASS SHEATHING 3/4" PLYWOOD UNFACED BATT INSULATION WD FRAMING - REFER TO STRUCTURAL DRAWINGS EXTEND TPO ROOF MEMBRANNE AND SECURE AT LEAST 2'-0" MIN UNDER ROOF TILE EXISTING TO REMAIN ROOF STRUCTURE EXISTING SOFFIT TO REMAIN PREP AND PAINT AS REQIRED ALIGN ALIGN PROVIDE NEW SOFIT UNFACED BATT INSULATION 1/2" GWB 1'-0" CLEAR MIN 2'-0" MIN. MEMBRANE FALSHING - ADHERE TO WALL TPO ROOF MEMBRANNE PROVIDE BLOCKING AS REQUIRED BASE SECURMENT, NOT SHOWN SILL OPEN END OF END TILE OR PROVIDE BUG SCREEN NEW CEMENT PANELS ON PROPRIETARY CLIP SYSTEM 1" POLYMER-BASED EXTERIOR INSULATION. INSULATION COMPRESIVE STRENGTH OF 25 PSI MIN. NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER NEW SHEATHING NEW OR EXISTING 2X WD FRAMING, REFERENCE STRUCTURAL DRAWINGS EXISTING TO REMAIN OR PROVIDE NEW UNFACED BATT INSULATION. GC TO VIF. NEW BEAM. REFER TO STRUCTURAL DRAWINGS FOR DETAILS METAL FLASHING PROVIDE BUG SCREEN AT EXPOSED ENDS OF FIBER CEMENT PANEL WALLS NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM 5/8" DENSGLASS SHEATHING SOFFIT VENT SOFFIT DRIP EDGE UNFACED BATT INSULATION 1/2" RESILIANT CHANNEL EXISTING STRUCTURE TO REMAIN EXISTING EXTERIOR WALL.REPAIR AND PREPARE ETR EIFS AS REQUIRED TO RECEIVE NEW PAINT BACKER ROD AND CONTINUES SEALANT COLUMN BEYOND 2x WD FRAMING REFER TO STRUCTURAL DRAWINGS NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM 5/8" DENSGLASS SHEATHING 1/2" RESILIANT CHANNEL FULLY ADHERED, CONTINUOUS TPO ROOF MEMBRANE, EXTEND OVER PARAPET AND SECURE TO OUTSIDE FACE OF SHEATHING TAPERED RIGID INSULATION 3/4" PLYWOOD ROOF DRAIN - REFER TO PLUMBING DRAWINGS FOR DETAILS TURN FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER ON TOP OF WALL ADHERE ROOF MEMBRANE TO IT STRONG WALL REFER TO STRUCTURAL 1" POLYMER- BASED EXTERIOR INSULATION AND FINISHING SYSTEM NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER NEW SHEATHING FRAMING REFER TO STRUCTURAL 2x WOOD FRAMING REINSTALL STOREFRONT SAVED FROM DEMOLITION OR PROVIDE NEW TO MATCH EXISTING PROVIDE NEW STOREFRONT EDGE OF NEW CONCRETE SLAB PROVIDE NEW CERAMIC FLOOR TILE PROVIDE NEW GWB AND REPAIR EXISTING FINISH TO MATCH EXISTING WALL FINISH PROVIDE NEW GWB AND REPAIR EXISTING FINISH TO MATCH EXISTING WALL FINISH EXISTING DOOR TO REMAIN REINSTALL CARD READER SAVED FROM DEMOLITION FRAME NEW WALL CL WATERBLOCK SEAL PROTECTION BOARD MEMBRANE ROOFING - EXTEND 3/4" INTO BOWL DOME STRAINER WITH GRAVEL STOP RING CLAMPING RING CONNECT TO PIPE 2"6"4".1" EIFS SUBSTRATE 2x6 ROOF JOIST @ 16" O.C 2x6 WOOD STUD WALL 1" EIFS 16"X 6" PREFINISHED ALUMINUM SCUPPER PAN, WATERTIGHT CONT SEALANT TAPERED RIGID INSULATION SINGLE PLY MEMBRANE CONT UNDER SCUPPER, ATTACH TO EIFS MEMBRANE FLASHING CONT SEALANT CONT SEALANT SINGLE PLY MEMBRANE TO COUNTER FLASH WOOD BLOCKING 2x6 WOOD STUD WALL SUBSTRATE SUBSTRATE CONT SEALANT 2" DRIP EDGE LIP CONT CLEAT NOTE: SET BOTTOM OF 16"X 6" OVERFLOW SCUPPERS AT 3" ABOVE BOTTOM OF NEAREST DS COLLECTOR. CONT SEALANT WOOD BLOCKING TAPERED RIGID INSULATION 1'-6"1 5/8"1'-6"1 5/8"1 5/8"1'-9 1/4"1 5/8" 1'-9 1/4" STRONG WALL REFER TO STRUCTURAL 1" POLYMER- BASED EXTERIOR INSULATION AND FINISHING SYSTEM ALL 4 SIDES NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER ALL 4 SIDES NEW SHEATHING ALL 4 SIDES FRAMING REFER TO STRUCTURAL 2x WOOD FRAMING EXISTING STOREFRONT TO REMAIN 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM EXISTING EXTERIOR WALL. PREPARE ETR EIFS AS REQUIRED TO RECEIVE NEW PAINT NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER FOR SHEATHING, FRAMING & FOUNDATION REFER TO STRUCTURAL DRAWINGS EDGE OF NEW CONCRETE SLAB BELOW. REFER TO STRUCTURAL DRAWINGS UNFACED BATT INSULATION 5/8" GWB. PROVIDE NEW AND REPAIR EXISTING WALLS AS REQUIRED. BACKER ROD AND CONTINUES SEALANT PROVIDE NEW STOREFRONT. FINISH TO MATCH EXISTING ADJACENT STOREFRONT. A.002 2B COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 12:15:17 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtDETAILS - MAIN ENTRANCE 05/14/2019 - PERMIT SET A.402c 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 1 1/2" = 1'-0" DRAWING REF: A.402a6AMAIN ENTRY BUILDOUT - PLAN DETAIL SCALE: 1 1/2" = 1'-0" DRAWING REF: A.401b5EMAIN ENTRY BUILDOUT - DETAIL SCALE: 1 1/2" = 1'-0" DRAWING REF: A.402b4DMAIN ENTRY BUILDOUT - DETAIL SCALE: 1 1/2" = 1'-0" DRAWING REF: A.401b3CMAIN ENTRY BUILDOUT - DETAIL SCALE: 1 1/2" = 1'-0" DRAWING REF: A.402b3AMAIN ENTRY BUILDOUT - DETAIL SCALE: 1 1/2" = 1'-0" DRAWING REF: A.402b6DMAIN ENTRY BUILDOUT - DETAIL SCALE: 1 1/2" = 1'-0" DRAWING REF: A.402a6CMAIN ENTRY BUILDOUT - PLAN DETAIL SCALE: 1 1/2" = 1'-0"4C TYPICAL DETAIL - ROOF DRAIN SCALE: 1 1/2" = 1'-0"4B TYPICAL DETAIL - OVERFLOW SCUPPER SCALE: 1 1/2" = 1'-0" DRAWING REF: A.402a6BMAIN ENTRY BUILDOUT - PLAN DETAIL SCALE: 1 1/2" = 1'-0" DRAWING REF: A.402a5BMAIN ENTRY BUILDOUT - PLAN DETAIL SCALE: 1 1/2" = 1'-0" DRAWING REF: A.402b4AMAIN ENTRY BUILDOUT - DETAIL KEYNOTES 05/14/2019 A.403b 1A 2A A.403c 4A A.403c A.403d 1A A.403d 2A A.403d 2B 8'-3 1/2"7'-11 1/2" 07.24.13.A 4C A.403c A.403b 5C A.403b 3C 2C A.403c A.403d 2B A.403d 2A A.403d 1A 07.42.5007.42.50 07.24.13.A07.24.13.A A.403b 3A A.403b 1A 2A A.403c A.403b 5A 4A A.403c SLOPE 1/4":1'-0" MIN22.14.28.B 22.14.28.A 07.72.00.C A.403b 5C A.403b 3C SLOPE 1/4":1'-0" MINEXISTING SLOPE22.14.28.B 22.14.28.A 4C A.403c 2C A.403c 1A A.403d 07.42.5007.42.50 07.24.13.A07.24.13.A 2A A.403c 4A A.403c A.403d 3A 07.42.50 07.24.13.A07.24.13.A07.24.13.A COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 12:15:28 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtENLARGED PLANS, REFLECTED CEILING PLANS & DETAILS - FRONT STAIRCASE #1 & #2 05/14/2019 - PERMIT SET A.403a 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 1/4" = 1'-0" DRAWING REF: A.1111AENLARGED FIRST FLOOR PLAN - STAIRCASE #1 SCALE: 1/4" = 1'-0" DRAWING REF: A.1111CENLARGED FIRST FLOOR PLAN - STAIRCASE #2 SCALE:6E PERSPECTIVE - STAIRCASE #1 KEYNOTES 07.24.13.A EIFS COATINGS - REFER TO ELEVATIONS FOR COLOR 07.42.50 NICHINA FIBER CEMENT PANEL SYSTEM. 07.72.00.C MODIFY EXCISING VENT AND FLASH AS REQUIRED FOR NEW ROOF. ELEVATION. 22.14.28.A PRIMARY ROOF DRAIN. CONCEAL PRIMARY ROOF DRAIN IN ROOF ASSEMBLY. CONNECT TO UNDERGROUND STORM/SEVER RUNOFF SYSTEM. WHEN POSSIBLE LOCATE TO EXISTING LOCATION FROM DEMOLISHED DOWNSPOUT 22.14.28.B OVERFLOW ROOF DRAIN. SCALE: 1/4" = 1'-0" DRAWING REF: A.1145AENLARGED ROOF PLAN - STAIRCASE #1 SCALE: 1/4" = 1'-0" DRAWING REF: A.1145CENLARGED ROOF PLAN - STAIRCASE #2 SCALE:4E PERSPECTIVE - STAIRCASE #2 SCALE: 1/4" = 1'-0"3C ENLARGED SECOND FLOOR PLAN - STAIRCASE #2 SCALE: 1/4" = 1'-0"3A ENLARGED SECOND FLOOR PLAN - STAIRCASE #1 05/14/2019 2A A.403c 4A A.403c ? FC-1 EF-3 E.Q.E.Q.E.Q.E.Q. EF-3 EF-3FC-1 4C A.403c 2C A.403c EF-3 2A A.403c 4A A.403c EF-3 4C A.403c 2C A.403c FC-1 EF-3 EF-3 EF-2 EF-3 FC-1 EF-3 EF-3 EF-3 E.Q.E.Q.E.Q.3'-4"+/- 30'-10"+/- 35'-2"26'-3 1/2" COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 12:15:29 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtENLARGED ELEVATIONS - FRONT STAIRCASE #1 & #2 05/14/2019 - PERMIT SET A.403b 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 1/4" = 1'-0" DRAWING REF: A4011ASTAIRCASE #1 - PARKING ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A.403a3ASTAIRCASE #1 - FRONT ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: xG0021CSTARICASE #2 - COURTYARD ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A.403a5ASTAIRCASE #1 - COURTYARD ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A.403a5CSTAIRCASE #2 - PARKING ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A.1103CSTARICASE #2 - FRONT ELEVATION KEYNOTES 05/14/2019 1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" T.O. PLATTE 26' -9 3/4" HIGH EAVE 30' -9 3/4" LOW EAVE 28' -3 3/4" 1st Floor 0' -0" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" 1st Floor 0' -0" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" A.403d 4C SIM A.403d 2C SIM High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" A.402c 3C SIM 1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" T.O. PLATTE 26' -9 3/4" HIGH EAVE 30' -9 3/4" LOW EAVE 28' -3 3/4" 1st Floor 0' -0" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" 1st Floor 0' -0" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" A.403d 4C SIM 1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" T.O. PLATTE 26' -9 3/4" HIGH EAVE 30' -9 3/4" LOW EAVE 28' -3 3/4" 1st Floor 0' -0" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" Level 1 0' -0" Level 2 10' -0" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" 1st Floor 0' -0" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" A.403d 4B A.403d 4C A.403d 2C Level 1 0' -0" Level 2 10' -0" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" A.402c 3C SIM 1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" T.O. PLATTE 26' -9 3/4" HIGH EAVE 30' -9 3/4" LOW EAVE 28' -3 3/4" 1st Floor 0' -0" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" Level 1 0' -0" Level 2 10' -0" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" 1st Floor 0' -0" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" Level 1 0' -0" Level 2 10' -0" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" A.403d 4C SIM 07.24.13.A 07.24.13.A 07.24.13.A 07.42.50 COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 12:15:31 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtENLARGED SECTIONS & DETAILS - FRONT STARICASE #1 & #2 05/14/2019 - PERMIT SET A.403c 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 1/4" = 1'-0" DRAWING REF: A.2014CSTAIRCASE #2 - SECTION SCALE: 1/4" = 1'-0" DRAWING REF: A.2022CSTAIRCASE #2 - SECTION SCALE: 1/4" = 1'-0" DRAWING REF: A.403a2ASTAIRCASE #1 - SECTION SCALE: 1/4" = 1'-0" DRAWING REF: A.403a4ASTAIRCASE #1 - SECTION KEYNOTES 07.24.13.A EIFS COATINGS - REFER TO ELEVATIONS FOR COLOR 07.42.50 NICHINA FIBER CEMENT PANEL SYSTEM. 05/14/2019 BACKER ROD AND CONTINUOUS SEALANT, PER PANEL REQ. FIBER CEMENT PANELS ON PROPRIETARY CLIP SYSTEM NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION. INSULATION COMPRESSIVE STRENGTH OF 25 PSI NEW SHEATHING EXISTING WALL TO REMAIN. REMOVE SHEATHING AND EIFS FINISH AND PREPARE TO RECEIVE NEW. FRAMING MAY VARIES. GC TO VIF WRAP IN METAL - FINISH TO MATCH FIBER CEMENT PANELS NEW SHEATHING TIE STEEL ANGLE TO EXISTING FRAMING. GC TO VIF FACE OF FIBER CEMENT PANEL ABOVE 1" POLYMER- BASED EXTERIOR INSULATION AND FINISHING SYSTEM NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER CAULK 1/2" MIN. - 1" MAX. 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER FOR SHEATHING, FRAMING & FOUNDATION REFER TO STRUCTURAL DRAWINGS CONCEAL STORM PIPE WITHIN NEW STRUCTURE EXISTING EXTERIOR WALL FRAMING AND INSULATION. REMOVE EIFS AND SHEETING TO THE EXTEND SHOWN EXISTING TO REMAIN WALL SHEATHING AND EIFS. FRAMING MAY VARIES. GC TO VIF 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER FOR SHEATHING, FRAMING & FOUNDATION REFER TO STRUCTURAL DRAWINGS NEW SHEATHING 2'-6".1'-0". EXISTING WALL TO REMAIN. REMOVE SHEATHING AND EIFS FINISH AND PREPARE TO RECEIVE NEW. FRAMING MAY VARIES. GC TO VIF EXISTING STORE FRONT TO REMAIN EXISTING STEEL DOOR AND FRAME TO REMAIN FIBER CEMENT PANELS ON PROPRIETARY CLIP SYSTEM NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER OVER: OVER: 1" POLYMER-BASED EXTERIOR INSULATION. INSULATION COMPRESSIVE STRENGTH OF 25 PSI OVER: NEW SHEATHING TRIM WITH METAL ON EXPOSED ENDS BACKER ROD AND CONTINUOUS SEALANT, PER PANEL REQ. PREFABRICATED OVERHANG FLASHING BY FIBER CEMENT PANELS MANUFACTURER EXISTING EFIS TO REMAIN. PREP AS REQUIRED TO RECEIVE NEW PAINT FINISH FIBER CEMENT PANELS ON PROPRIETARY CLIP SYSTEM NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION. INSULATION COMPRESSIVE STRENGTH OF 25 PSI NEW SHEATHING EXISTING WD STRUCTURE TO REMAIN. REMOVE SHEATHING AND EXTERIOR WALL FINISH REPAIR AS REQUIRED WITH POLYMER- BASED EXTERIOR INSULATION AND FINISHING SYSTEM. MATCH ADJACENT EXISTING ADJACENT EFIS THICKENS AND FINISH NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM 5/8" DENSGLASS SHEATHING 1/2" RESILIANT CHANNEL SOFFIT VENT SOFFIT DRIP EDGE NEW FRAMING REFER TO STRUCTURAL DRAWINGS NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM 5/8" DENSGLASS SHEATHING UNFACED BATT INSULATION PREMANUFACTURED COPING - METAL ERA PERMA TITE CONTINUOUS CLEAT COPING BUTYL SEALING TAPE FULLY ADHERED, CONTINUOUS TPO ROOF MEMBRANE, EXTEND OVER PARAPET AND SECURE TO OUTSIDE FACE OF SHEATHING TAPERED RIGID INSULATION PLYWOOD ROOF FRAMING, REFERENCE STRUCTURAL DRAWINGS UNFACED BATT INSULATION 5 1/2" CL FIBER CEMENT PANELS ON PROPRIETARY CLIP SYSTEM NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION. INSULATION COMPRESSIVE STRENGTH OF 25 PSI NEW SHEATHING EXISTING WD STRUCTURE TO REMAIN. REMOVE SHEATHING AND EXTERIOR WALL FINISH BACKER ROD AND CONTINUES SEALANT EXTERIOR RECESSED LIGHT FIXTURE, REFERENCE ELECTRICAL DRAWINGS FOR MORE INFORMATION FRAME NEW WALL OVER EXISTING WALL. REFER TO STRUCTURAL DRAWINGS FOR DETAILS TURN FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER ON TOP OF WALL ADHERE ROOF MEMBRANE TO IT MAINTAIN EXISTING FIRE RATING DURING CONSTRUCTION NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM NEWSHEATHING UNFACED BATT INSULATION PREMANUFACTURED COPING - METAL ERA PERMA TITE CONTINUOUS CLEAT COPING BUTYL SEALING TAPEFULLY ADHERED, CONTINUOUS TPO ROOF MEMBRANE, EXTEND OVER PARAPET AND SECURE TO OUTSIDE FACE OF SHEATHING TAPERED RIGID INSULATION 3/4" PLYWOOD TURN FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER ON TOP OF WALL ADHERE ROOF MEMBRANE TO IT 1/2" MIN. - 1" MAX.NEW SHEATHING EXISTING WALL TO REMAIN. REMOVE SHEATHING AND EIFS FINISH AND PREPARE TO RECEIVE NEW. FRAMING MAY VARIES. GC TO VIF WRAP IN METAL - FINISH TO MATCH FIBER CEMENT PANELS 1" POLYMER-BASED EXTERIOR INSULATION AND FINISHING SYSTEM NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER CAULK NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION. INSULATION COMPRESSIVE STRENGTH OF 25 PSI NEW SHEATHING BACKER ROD AND CONTINUOUS SEALANT, PER PANEL REQ. FIBER CEMENT PANELS ON PROPRIETARY CLIP SYSTEM COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 12:15:32 PM C:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtDETAILS - FRONT STIARCASE 05/14/2019 - PERMIT SET A.403d 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA KEYNOTES SCALE: 1 1/2" = 1'-0" DRAWING REF: A.403a2AENLARGED PLAN DETAIL SCALE: 1 1/2" = 1'-0" DRAWING REF: A.403a1AENLARGED DETAIL - FOCAL WALL SCALE: 1 1/2" = 1'-0" DRAWING REF: A.403a2BENLARGED PLAN DETAIL SCALE: 1 1/2" = 1'-0" DRAWING REF: A.403c4BENLARGED SECTION DETAIL SCALE: 1 1/2" = 1'-0" DRAWING REF: A.403c4CENLARGED SECTION DETAIL SCALE: 1 1/2" = 1'-0" DRAWING REF: A.403c2CENLARGED SECTION DETAIL SCALE: 1 1/2" = 1'-0" DRAWING REF: A.403a3AENLARGED PLAN DETAIL 05/14/2019 -A.404a 3C -A.404a 2C -A.404a1C 4C -A.404a A.403d 2A A.403d 2B 23.07.19.A 4C -A.404a 07.24.13.B07.24.13.B 07.42.50.B +/- 1'-0"+/- 18'-5 1/4"+/- 1'-0"+/- 9'-0 1/4"+/- 29' -5 1/2"1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" T.O. PLATTE 26' -9 3/4" HIGH EAVE 30' -9 3/4" LOW EAVE 28' -3 3/4" 1st Floor 0' -0" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" 1st Floor 0' -0" High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" -A.404a 6D -A.404a 6C -A.404a 6A -A.404a 6D SIM High Eave 30' -9 3/4" Low Eave 28' -3 3/4" T.O. Platte 26' -9 3/4" 3RD FLOOR 18' -7" 2ND FLOOR 9' -3" 1ST FLOOR 0' -0" 4C -A.404a EXISTING SITE CONDITION. VERIFY IN FIELD. B.O. FIBER CEMENT PANEL TO BE HELD 2" MIN ABOVE BOTH SOIL AND HARDSCAPING. NEW METAL FLASHING FIBER CEMENT PANELS ON PROPRIETARY CLIP SYSTEM NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION. INSULATION COMPRESSIVE STRENGTH OF 25 PSI MIN2"PROVIDE BUG SCREEN AT EXPOSED ENDS OF FIBER CEMENT PANEL WALLS NEW SHEATHING EXISTING WD STUD WALL TO REMAIN. REMOVE SHEATHING AND EXTERIOR WALL FINISH EXISTING TO REMAIN ROOF STRUCTURE EXISTING TO REMAIN ROOF TILE FIBER CEMENT PANEL ON PROPRIETARY CLIP SYSTEM 1" POLYMER-BASED EXTERIOR INSULATION. INSULATION COMPRESSIVE STRENGTHS OF 25 PSI MIN. NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 5/8" DENSGLASS SHEATHING PROVIDE NEW GALV. COUNTERFLASHING POP RIVETS AT 12" OC. EXISTING WALL TO REMAIN. REMOVE SHEATHING AND EIFS FINISH AND PREPARE TO RECEIVE NEW EXISTING WALL AND SHEATING TO REMAIN. GC TO VERFY EXISTING BLOCKING LOCATION OVRLAP EXISTING ROOF FELT UNDER NEW VAPER BARRIER PROVIDE BUG SCREEN AT EXPOSED ENDS OF FIBER CEMENT PANEL WALLS 6" MIN.SOFT COPPER SHAPED TO CONFORM TILE PROFILE FIBER CEMENT PANELS ON PROPRIETARY CLIP SYSTEM NEW FLUID-APPLIED VAPOR PERMEABLE AIR BARRIER 1" POLYMER-BASED EXTERIOR INSULATION. INSULATION COMPRESSIVE STRENGTH OF 25 PSI NEW SHEATHING EXISTING WD STUD WALL TO REMAIN. REMOVE SHEATHING AND EXTERIOR WALL FINISH EXISTING TO REMAIN ROOF TRUSS BACKER ROD AND CONTINUES SEALANT EXISTING TO REMAIN FACIA. PREP AND REPAIR AS REQUIRED FOR NEW PAINT FINISH EXISTING TO REMAIN GUTTER. PREP AND REPAIR AS REQUIRED FOR NEW PAINT FINISH EXISTING TO REMAIN ROOF TILE COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.211/21/2019 4:38:08 PM C:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtENLARGED PLANS, REFLECTED CEILING PLANS & DETAILS - SIDE ENTRANCE 05/14/2019 - PERMIT SET A.404a 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA KEYNOTES 07.24.13.B REVEAL IN EIFS COATINGS 07.42.50.B CORNER TRIM 23.07.19.A EXISTING TO REMAIN HVAC UNIT. KEEP AND PROTECT DURING CONSTRUCTION. MODIFY ELECTRICAL CONNECTIONS AND LINES AS REQUIRED FOR NEW CONSTRUCTION SCALE: 1/4" = 1'-0" DRAWING REF: -A.404a3CELEVATION - SIDE ENTRANCE SCALE: 1/4" = 1'-0"1A ENLARGED FIRST FLOOR PLAN - SIDE ENTRANCE SCALE:6E PERSPECTIVE SCALE: 1/4" = 1'-0" DRAWING REF: -A.404a2CELEVATION - SIDE ENTRANCE SCALE: 1/4" = 1'-0" DRAWING REF: -A.404a1CELEVATION - SIDE ENTRANCE SCALE: 1/4" = 1'-0" DRAWING REF: -A.404a4CSECTION - SIDE ENTRANCE SCALE: 1/4" = 1'-0"3A ENLARGED SECOND FLOOR PLAN - SIDE ENTRANCE SCALE: 1 1/2" = 1'-0" DRAWING REF: -A.404a6ADETAIL - SIDE ENTRANCE SCALE: 1 1/2" = 1'-0" DRAWING REF: -A.404a6CDETAIL - SIDE ENTRANCE SCALE: 1 1/2" = 1'-0" DRAWING REF: -A.404a6DDETAIL - SIDE ENTRANCE C 11/20/2019 BUILDING PERMIT REVIEW - REVISION #3 C 11/22/2019 5A A.405 A.4052B A.405 3B A.405 3C A.405 4B 1/2" GWB ON FURRING STRIPS CONTINUOUS TPO ROOF MEMBRANE EXISTING STRUCTURE TO REMAIN STRUCTURE PLYWOOD AND CANOPY STRUCTURE - REFER TO STRUCTURAL DRAWINGS 6B A.405 MEMBRANE FLASHING - ADHERE TO WALL PROVIDE BLOCKING AS REQUIRED PRE-FIN MET GUTTER. MATCH STYLE OF EXISTING GUTTERS. PAINT TO MATCH BRONZE FINISH METAL WRAP DARK BRONZE FINISH COATED MET DRIP EDGE MEMB FLASH FASTNER 4" OC STAGGERED PROVIDE BLOCKING AS REQ CAULK HEAT WELDED SEAM (TYP) CAULK LIGHT FIXTURE - REFER TO ELECTRICAL DRAWINGS EXISTING WALL, SHEATHING AND EIFS FINISH TO REMAIN. PREPARE TO RECEIVE NEW PAINT FINISH. EXISTING WALL, SHEATHING AND EIFS FINISH TO REMAIN. PREPARE TO RECEIVE NEW PAINT FINISH. PROVIDENEW EFIS AND SHEETING AS REQUIRED PROVIDENEW EFIS AND SHEETING AS REQUIRED A 5A A.405 A.405 6B EF-2EF-1 EF-4 6B A.405 6A A.405 3' - 6".19'-0 3/4"10"8'-5"+/- 28'-3 3/4"EF-4 EF-4 A 6B A.405 6A A.405 1/2" GWB ON FURRING STRIPS METAL WRAP DARK BRONZE FINISH COATED MET DRIP EDGE MEMB FLASH FASTNER 4" OC STAGGERED CAULK EIFS (EF-4) EIFS (EF-4) EIFS - (EF-2) EIFS (EF-2) FRAMING - REFER TO STRUCTURAL 1/4" GALV ST GUTTER BRACKETS @ 3'-0" OC (PAINT TO MATCH) MIDPOINT BETWEEN GUTTER STRAPS 1/8" GALV ST GUTTER BRACKETS @ 3'-0" OC (PAINT TO MATCH) MIDPOINT BETWEEN GUTTER STRAPS 4" x 4" PRE-FIN MET GUTTER EDGE OF CANOPY ABOVE EXISTING WALL, SHEATHING AND EIFS FINISH TO REMAIN. PREPARE TO RECEIVE NEW PAINT FINISH. PROVIDE EIFS REPAIR AS REQUIRED WITH POLYMER- BASED EXTERIOR INSULATION AND FINISHING SYSTEM. MATCH ADJACENT EXISTING ADJACENT EFIS THICKNES AND FINISH 1/2"3 1/2"1" GALVANAIZE FLASHING - COLOR MATCH FIBER CEMENT PANELS PROVIDE BLOCKING AS REQUIRED CAULK STRUCTURAL MEMBER - REFER TO STRUCTURAL DRAWINGS. BUILD OUT AROUND NEW STRUCTURE +/- 10"WRAP IN METAL. DARK BRONZE FINISH EXISTING WALL, SHEATHING AND EIFS FINISH TO REMAIN. PREPARE TO RECEIVE NEW PAINT FINISH. EXISTING WALL, SHEATHING AND EIFS FINISH TO REMAIN. PREPARE TO RECEIVE NEW PAINT FINISH. A 5A A.405 A.4052B A.405 3B A.405 3C 6B A.405 19'-2 1/16"12'-11 1/2"1 1/2"6'-6 3/4"5 1/2"3'-8"4'-10"3'-8"5 1/2"1'-4 1/2" NOT FOR CONSTRUCTION COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.27/2/2019 5:54:06 PMC:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtENLARGED PLANS, REFLECTED CEILING PLANS & DETAILS - REAR STAIRCASE 05/14/2019 - PERMIT SET A.405 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 1/4" = 1'-0" DRAWING REF: A.1111A ENLARGED FIRST FLOOR PLAN REAR ENTRANCE KEYNOTES SCALE:6E PERSPECTIVE SCALE: 1 1/2" = 1'-0" DRAWING REF: A.2015ASECTION - REAR ENTRANCE SCALE: 1/4" = 1'-0" DRAWING REF: A.4052BELEVATION - REAR ENTRANCE SCALE: 1/4" = 1'-0" DRAWING REF: A.4053BELEVATION - REAR ENTRANCE SCALE: 1/4" = 1'-0" DRAWING REF: A.4053CELEVATION - REAR ENTRANCE SCALE: 1 1/2" = 1'-0" DRAWING REF: A.4056BSECTION - REAR ENTRANCE SCALE: 1 1/2" = 1'-0" DRAWING REF: A.4054BENLARGED PLAN DETAIL SCALE: 1 1/2" = 1'-0" DRAWING REF: A.4056ASECTION - REAR ENTRANCE SCALE: 1/4" = 1'-0"3A ENLARGED SECOND FLOOR PLAN REAR ENTRANCE SCALE: 1/4" = 1'-0"2A ENLARGED FIRST FLOOR PLAN REAR ENTRANCE RCP A A A A A A 07/03/2019 PRELIMINARY REVIEW - REVISION 07/16/2019 A.406 1C A.406 4C A.4063C BIN 1 BIN 2 CART 2 CART 1 STEEL GATE EXTENT OF CONCRETE PAD - FLUSH WITH ADJACENT ASPHALT CONCRETE PAD CMU WALL ON CONCRETE FOOTING 8" HIGH CONCRETE CURB - EXTEND 8" INTO INTERIOR 8"18'-1 1/2"15'-6"8"10 3/4"NEW CURB 2'-1"ALIGN NEW STORM DROP INLET & GRATE (CB-2) - GC TO TIE INTO EXISTING STORM SEWER - PROVIDE FULL TRASH CAPTURE (SEE TRASH CAPTURE LEGEND ON A.110) NEW FENCE TO MATCH EXISTING EXISTING FENCE & GATE EQEQ7'-0" CL CL D D D D 15'-0"19'-2 3/4"5'-0"D D D TRASH ENCLOSURE 240 SF D 6'-0"METAL ROOF & FRAME PER STRUCTURAL STEEL POST STUCCO FINISH OVER CMU WALL ON CONCRETE FOOTING 1'-0"1'-0" STEEL GATE & HINGES WELDED TO STEEL POST GATE B.O.D. - AMETCO ROLLING CANTILEVER GATE (GALV. STEEL)NATURAL GRADE TO TOP OF ROOF9'-9"D DCLEAR8'-6"STEEL POST -SEE STRUCTURAL METAL ROOF & FRAME -SLOPE 1/4" PER FOOT STUCCO FINISH OVER CMU WALL ON CONCRETE FOOTING 1'-0" 1'-0" METAL GUTTER & DOWNSPOUT NATURAL GRADE TO TOP OF ROOF9'-9"D METAL ROOF & FRAME -SLOPE 1/4" PER FOOT STUCCO FINISH OVER CMU WALL ON CONCRETE FOOTING METAL GUTTER & DOWNSPOUT CLEAR8'-6"NATURAL GRADE TO TOP OF ROOF9'-9"D D EXISTING WOOD TRASH ENCLOSURE TO BE DEMOLISHED 6'-9"10'-9 1/4"5'-6"11'-8 1/4"5'-6"EXISTING WOOD TRASH ENCLOSURE TO BE DEMOLISHED 5'-6"23'-11 1/4" EXISTING WOOD TRASH ENCLOSURE TO BE DEMOLISHED EXISTING FENCE TO REMAIN A.406 2D A.406 4D A.4063D 23'-11 1/4"11'-8 1/4"6'-9"2'-7"10'-9 1/4"EXISTING FENCE TO REMAIN TRASH ENCLOSURE WOOD FENCE TO BE DEMOLISHED COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:54:19 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtTRASH ENCLOSURE DETAILS 05/14/2019 - PERMIT SET A.406 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA C 11/20/2019 BUILDING PERMIT REVIEW - REVISION #3 D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 SCALE: 1/4" = 1'-0" DRAWING REF: A.1102AENLARGED PLAN - TRASH ENCLOSURE SCALE: 1/4" = 1'-0" DRAWING REF: A.4061CELEVATION - TRASH ENCLOSURE FRONT SCALE: 1/4" = 1'-0" DRAWING REF: A.4064CELEVATION - TRASH ENCLOSURE SIDE SCALE: 1/4" = 1'-0" DRAWING REF: A.4063CELEVATION - TRASH ENCLOSURE REAR SCALE: 1/4" = 1'-0" DRAWING REF: A.4063DELEVATION - EXISTING TRASH ENCLOSURE REAR SCALE: 1/4" = 1'-0" DRAWING REF: A.4064DELEVATION - EXISTING TRASH ENCLOSURE SIDE SCALE: 1/4" = 1'-0" DRAWING REF: A.4062DELEVATION - EXISTING TRASH ENCLOSURE FRONT D SCALE: 1/8" = 1'-0" DRAWING REF: D.1106DDEMOLITION PLAN - EXISTING TRASH ENCLOSURE 02/21/2020 DN DN 02.41.19.64 02.41.19.64 (30 TOTAL COURTYARD - GC TO VIF) (18 TOTAL EXTERIOR - GC TO VIF) 02.41.19.60 02.41.19.60 02.41.19.60 02.41.19.6002.41.19.60 02.41.19.71 02.41.19.72 02.41.19.72 02.41.19.73 02.41.19.78 PUBLIC RIGHT OF WAY/ PUBLIC SIDEWALK N WOLFE ROAD PUBLIC SIDEWALK DEMOLISH PORTION OF EXISTING CHAIN LINK FENCE EXTENDING BEYOND WOOD FENCE EXISTING TO REMAIN "DOG EAR" WOOD PRIVACY FENCE (+/- 6' HIGH) 02.41.19.80 02.41.19.80 A.406 6D D COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:54:21 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtDEMOLITION - SITE PLAN 05/14/2019 - PERMIT SET D.110 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 1/16" = 1'-0" DRAWING REF: -A.404a6ADEMOLITION PLAN - SITE KEYNOTES 02.41.19.60 REMOVE LANDSCAPING AS REQUIRED FOR CONSTRUCTION 02.41.19.64 REMOVE BOLLARD LIGHTS AND PREP TO RECEIVE NEW LIGHT FIXTURE. REFER TO ELECTRICAL DRAWINGS FOR DETAILS 02.41.19.71 REMOVE BACK LIGHTED SIGNAGE. RETURN WIRING BACK TO SOURCE. PATCH END REPAIR ADJACENT SURFACES AS REQUIRED. REFER TO ELECTRICAL DRAWINGS FOR DETAILS 02.41.19.72 REMOVE EXISTING SIGNAGE. KEEP AND PROTECT POWER CONNECTION FOR FUTURE SIGNAGE. REFER TO ELECTRICAL DRAWINGS FOR DETAILS 02.41.19.73 *ADD ALT* PREP AS REQUIRED FOR NEW BICYCLE PARKING 02.41.19.78 DEMOLISH EXISTING TRASH ENCLOSURE 02.41.19.80 DEMOLISH EXISTING ENTRY CANOPY AND SIDEW ALLS A 07/03/2019 PRELIMINARY REVIEW - REVISION C 11/20/2019 BUILDING PERMIT REVIEW - REVISION #3 D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 NSWE100.00° D 02/21/2020 DN DN J J J C CCCC D.201 6A D.201 6B D.201 5C D.2015E D.202 6B D.202 3ED.2023CD.202 6A 02.41.19.53 02.41.19.53 02.41.19.61 02.41.19.52 02.41.19.52 02.41.19.59 02.41.16.01 02.41.19.58 02.41.19.50 02.41.16.01 02.41.19.50 02.41.19.5602.41.19.5602.41.19.56 02.41.19.52 02.41.19.53 02.41.19.54 02.41.19.55 02.41.19.57 02.41.19.53 02.41.19.60 02.41.19.59 02.41.19.63 02.41.19.63 02.41.19.59 02.41.16.01 02.41.16.01 02.41.19.5402.41.19.54 02.41.19.62 02.41.19.52 02.41.19.5202.41.19.52 02.41.19.5202.41.19.52 02.41.19.52 02.41.19.52 02.41.19.71 02.41.19.75 02.41.19.76 02.41.19.74 A.203 6A A.203 6B A.203 4C A.2034EA.204 6B A.204 3EA.2043CA.204 6A K1-R 112 QQ1-R 116 K1-L 118 K1-L 119 K1-R 120 K1C-R 121 QQ1-L 122 QQARI-L 123 QQ1-R 124 QQ1-R 125 QQ2C-L 126 QQ1-L 127 KS1-L 128 K1C-R 129 K1C-L 131 K1-R 133 K1-L 135 K1-R 137 K1-L 139 K1C-R 141 KS1-R 142 QQ1C-L 143 QQ2C-R 144 QQ1C-R 145 QQ1-L 146 KA1-L 147 K1-R 148 K1-R 149 K1-L 150 K1-R 152 QQ1-L 154 QQ1-R 156 K1-L 155 K1-R 157 K1-L 158 K2C-R 160 KSARI-L 162 K1-R 101 K1-L 103 K1C-R 105 K1C-L 107 DDS2-R 108 K1-R 109 K2C-L 110 K1-L 111 K1-R 115 QQ1-L 114 LOBBY 1.10 EMPLOYEE LOUNGE 1.11 MEETING ROOM A 1.12 MEETING ROOM B 1.13 GUEST LAUNDRY 1.14 FITNESS ROOM 1.15 VESTIBULE 1.10A CORRIDOR 1.04 ELEV LOBBY 1.04A CORRIDOR 1.03 ICE 1.03A CORRIDOR 1.01 ELEVATOR LOBBY 1.01B CORRIDOR 1.02 STAIR #1 ST1.01 STAIR #2 ST2.01 ELEV #2 EL.2 ELEV #1 EL.1 STAIR #3 ST3.01 STAIR #4 ST4.01 DEMO WORK POCHE LEGEND - DEMO LANDSCAPE DEMO NIC NOT FOR CONSTRUCTION COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.27/2/2019 5:54:13 PMC:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtDEMOLITION - 1ST FLOOR PLAN 05/14/2019 - PERMIT SET D.111 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 3/32" = 1'-0" DRAWING REF: A.401b6ADEMOLITION PLAN - OVERALL GROUND FLOOR KEYNOTES 02.41.16.01 REMOVE COLUMNS AND CONCRETE FOOTINGS. REFER TO STRUCTURAL DRAWINGS FOR DETAILS. 02.41.19.50 REMOVE PORTE COCHERE & PORTE COCHERE LIGHTING. REFER TO ELECTRICAL DRAWINGS FOR DETAILS 02.41.19.52 REMOVE DOWN SPOUTS AND DISCONETCT FOR EXISTING TO REMAIN UNDERGROUND DRAINAGE 02.41.19.53 REMOVE FINISH AND SUBSTRATE TO EXTEND SHOWN 02.41.19.54 SALVAGE BANQUET SEATING AND STORE FOR REUSE 02.41.19.55 REMOVE FLOORING AT EXTEND SHOWN 02.41.19.56 REMOVE BAY WINDOWS 02.41.19.57 REMOVE CEILING AT BAY WINDOWS 02.41.19.58 REMOVE STOREFRONT 02.41.19.59 SALVAGE AUTOMATIC DOOR OPENER / CARD READER DOOR HARDWARE 02.41.19.60 REMOVE LANDSCAPING AS REQUIRED FOR CONSTRUCTION 02.41.19.61 REMOVE LIGHT FIXTURE. REFER TO ELECTRICAL DRAWINGS 02.41.19.62 EXISTING TO REMAIN WALL MOUNTED FIRE DEPARTMENT BOX. KEEP AND PROTECT DURING CONSTRUCTION 02.41.19.63 REMOVE WALLS AND ROOF AT REAR ENTRANCE. 02.41.19.71 REMOVE BACK LIGHTED SIGNAGE. RETURN WIRING BACK TO SOURCE. PATCH END REPAIR ADJACENT SURFACES AS REQUIRED. REFER TO ELECTRICAL DRAWINGS FOR DETAILS 02.41.19.74 EXISTING TO REMAIN HVAC UNIT. KEEP AND PROTECT DURING CONSTRUCTION. MODIFY ELECTRICAL CONNECTIONS AND LINES AS REQUIRED FOR NEW CONSTRUCTION 02.41.19.75 REMOVE CONCRETE SIDEWALK AS REQUIRED FOR NEW CONSTRUCTION 02.41.19.76 REMOVE STOOP CONCRETE AS REQUIRED FOR NEW CONSTRUCTION A A A 07/03/2019 PRELIMINARY REVIEW - REVISION 07/16/2019 D.201 6A D.201 6B D.201 5C D.2015E D.202 6B D.202 3ED.2023CD.202 6A 02.41.19.51 02.41.19.67 02.41.19.66 02.41.19.51 02.41.19.68 02.41.19.51 02.41.19.51 02.41.19.67 02.41.19.51 02.41.19.63 02.41.19.63 02.41.19.51 02.41.19.66 02.41.19.50 02.41.19.50 02.41.19.51 02.41.19.51 02.41.19.51 02.41.19.51 02.41.19.51 A A A.203 6A A.203 6B A.203 4C A.2034EA.204 6B A.204 3EA.2043CA.204 6A DEMO WORK POCHE LEGEND - DEMO LANDSCAPE DEMO NIC NOT FOR CONSTRUCTION COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.27/2/2019 5:54:15 PMC:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvtDEMOLITION PLAN - ROOF 05/14/2019 - PERMIT SET D.114 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 3/32" = 1'-0" DRAWING REF: A.403c6ADEMOLITION ROOF PLAN KEYNOTES 02.41.19.50 REMOVE PORTE COCHERE & PORTE COCHERE LIGHTING. REFER TO ELECTRICAL DRAWINGS FOR DETAILS 02.41.19.51 REMOVE ROOF FACIA AND GUTTERS TO EXTEND SHOW. 02.41.19.63 REMOVE WALLS AND ROOF AT REAR ENTRANCE. 02.41.19.66 REMOVE TERRACOTTA ROOF SHINGLES AND STORE FOR REUSE AND REPAIRS. EXISTING ROOF DECK TO REMAIN 02.41.19.67 REMOVE TERRACOTTA ROOF SHINGLES AND STORE FOR REUSE AND REPAIRS. REMOVE ROOF DECK AND TRUSSES AS REQUIRED FOR NEW CONSTRUCTION 02.41.19.68 REMOVE SKYLIGHT. A 07/03/2019 PRELIMINARY REVIEW - REVISION 07/16/2019 02.41.19.63 02.41.19.65 02.41.19.69 02.41.19.52 02.41.19.67 02.41.19.51 02.41.19.53 02.41.19.69 02.41.19.51 02.41.16.01 02.41.19.50 02.41.19.69 02.41.19.69 02.41.19.69 02.41.19.65 02.41.19.71 TYP. 02.41.19.6902.41.19.69 NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 45'-6"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 31'-8 1/2"NATURAL GRADE TO TOP OF PLATE TO BE DEMOLISHED+/- 29'-2 1/2"NATURAL GRADE TO TOP OF PLATE TO BE DEMOLISHED+/- 12'-10 3/4"NATURAL GRADE TO TOP OF PORTE COCHERE ROOF RIDGE TO BE DEMOLISHED+/- 19'-4 3/4"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 33'-1 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 47'-6 1/2"31.00.00.A 02.41.19.67 02.41.19.51 02.41.19.53 02.41.19.51 02.41.19.50 02.41.16.01 02.41.19.69 02.41.19.52 02.41.19.69 02.41.19.69 26.56.19.B02.41.19.65 02.41.19.63 3B D.301 2B D.301 02.41.19.69 02.41.19.69 02.41.19.69 02.41.19.6502.41.19.6502.41.19.6502.41.19.65 TYP. 02.41.19.6902.41.19.69 NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 42'-8"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/2"NATURAL GRADE TO TOP OF ROOF RIDGE TO BE DEMOLISHED+/- 32'-3 1/2"NATURAL GRADE TO TOP OF EXISTING / TO BE DEMOLSIHED PLATE+/- 27'-2 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 11'-10 3/4"NATURAL GRADE TO TOP OF PORTE COCHERE ROOF RIDGE TO BE DEMOLISHED+/- 18'-4 3/4"31.00.00.A 02.41.19.67 02.41.19.52 02.41.19.51 02.41.19.69 02.41.19.69 02.41.19.51 02.41.16.01 02.41.19.56 02.41.19.52 02.41.19.66 02.41.19.68 02.41.19.67 02.41.19.51 02.41.19.53 02.41.19.69 2A D.301 02.41.19.69 02.41.19.69 02.41.19.6902.41.19.69 02.41.19.52 4A D.301 NATURAL GRADE TO TOP OF PLATE OF PORTE COCHERE TO BE DEMOLISHED+/- 11'-10 3/4"NATURAL GRADE TO TOP OF PORTE COCHERE ROOF RIDGE TO BE DEMOLISHED+/- 18'-5 1/4"NATURAL GRADE TO TOP OF EXISTINGPLATE TO BE DEMOLISHED+/- 13'-10 3/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE TO BE BUILD OVER+/- 23'-10 3/4"31.00.00.A 6B D.301 02.41.19.63 02.41.19.52 02.41.19.52 02.41.19.63 02.41.19.6902.41.19.69 02.41.19.6902.41.19.69 02.41.19.6902.41.19.69 02.41.19.6902.41.19.69 02.41.19.53 02.41.19.6902.41.19.69 02.41.19.53 NATURAL GRADE TO TOP OF EXISTING PLATE+/- 12'-10 3/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 19'-3 3/4"31.00.00.A DEMO WORK POCHE LEGEND - DEMO LANDSCAPE DEMO NIC COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:54:28 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtDEMOLITION - EXTERIOR ELEVATIONS 05/14/2019 - PERMIT SET D.201 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 3/32" = 1'-0" DRAWING REF: A4106ADEMOLITION ELEVATION - EAST SCALE: 3/32" = 1'-0" DRAWING REF: A.4066BDEMOLITION ELEVATION - WEST SCALE: 3/32" = 1'-0" DRAWING REF: A.401a5CDEMOLITION ELEVATION - NORTH SCALE: 3/32" = 1'-0" DRAWING REF: D.1115EDEMOLITION ELEVATION - SOUTH KEYNOTES 02.41.16.01 REMOVE COLUMNS AND CONCRETE FOOTINGS. REFER TO STRUCTURAL DRAWINGS FOR DETAILS. 02.41.19.50 REMOVE PORTE COCHERE & PORTE COCHERE LIGHTING. REFER TO ELECTRICAL DRAWINGS FOR DETAILS 02.41.19.51 REMOVE ROOF FACIA AND GUTTERS TO EXTEND SHOW. 02.41.19.52 REMOVE DOWN SPOUTS AND DISCONETCT FOR EXISTING TO REMAIN UNDERGROUND DRAINAGE 02.41.19.53 REMOVE FINISH AND SUBSTRATE TO EXTEND SHOWN 02.41.19.56 REMOVE BAY WINDOWS 02.41.19.63 REMOVE WALLS AND ROOF AT REAR ENTRANCE. 02.41.19.65 REMOVE EXTERIOR GRADE WALL SCONE AND PREP TO RECEIVE NEW. REFER TO ELECTRICAL DRAWINGS FOR DETAILS 02.41.19.66 REMOVE TERRACOTTA ROOF SHINGLES AND STORE FOR REUSE AND REPAIRS. EXISTING ROOF DECK TO REMAIN 02.41.19.67 REMOVE TERRACOTTA ROOF SHINGLES AND STORE FOR REUSE AND REPAIRS. REMOVE ROOF DECK AND TRUSSES AS REQUIRED FOR NEW CONSTRUCTION 02.41.19.68 REMOVE SKYLIGHT. 02.41.19.69 PREPARE AS REQUIRED EXISTING TO REMAIN EIFS, TRIMS, FASCIAS, GUTTERS, RAIN LEADERS, HANDRAILS, GUARDRAILS, PTAC COVERS ETC TO RECEIVE NEW FINISH 02.41.19.71 REMOVE BACK LIGHTED SIGNAGE. RETURN WIRING BACK TO SOURCE. PATCH END REPAIR ADJACENT SURFACES AS REQUIRED. REFER TO ELECTRICAL DRAWINGS FOR DETAILS 26.56.19.B OFCI EXTERIOR GRADE SCONE LIGHT. INSTALL IN EXISTING LIGHT LOCATION. REFER TO ELECTRICAL DRAWINGS FOR DETAILS 31.00.00.A NATURAL GRADE - AS PER GRADING PLAN DATED 10/25/86 BY SANDIS AND ASSOCIATES INC. ENGINEERS, SURVEYORS AND PLANNERS A 07/03/2019 PRELIMINARY REVIEW - REVISION D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 D D D D 02/21/2020 02.41.16.01 02.41.19.50 02.41.19.51 02.41.19.53 02.41.19.66 02.41.19.51 02.41.19.67 02.41.19.6902.41.19.69 02.41.19.6902.41.19.69 02.41.19.63 5B D.301 02.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.6502.41.19.6502.41.19.65 TYP. TYP. 02.41.19.69 02.41.19.5202.41.19.52 NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 27'-2 1/2"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 43'-6"44'-11"02.41.19.63 02.41.19.6902.41.19.69 02.41.19.6902.41.19.69 02.41.19.65 02.41.19.52 02.41.19.67 02.41.19.51 02.41.19.50 02.41.16.01 02.41.19.51 02.41.19.6502.41.19.65 02.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.65 02.41.19.6502.41.19.65 02.41.19.6502.41.19.6502.41.19.65 02.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.65 02.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.65 02.41.19.6502.41.19.6502.41.19.65 02.41.19.5202.41.19.52 TYP.TYP.TYP. 02.41.19.69 31.00.00.ANATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/2"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 44'-1 1/2"NATURAL GRADE TO TOP OF EXISTING PLATE+/- 29'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 42'-8"44'-11"02.41.19.69 02.41.19.69 02.41.19.6902.41.19.69 02.41.19.69 02.41.19.69 NATURAL GRADE TO TOP OF EXISTING PLATE+/- 11'-8 1/4"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 18'-0 1/2"18'-1"02.41.19.6902.41.19.69 02.41.19.6902.41.19.6902.41.19.6902.41.19.69 02.41.19.65 02.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.6502.41.19.65 02.41.19.6902.41.19.69 TYP.NATURAL GRADE TO TOP OF EXISTING PLATE+/- 12'-8"NATURAL GRADE TO TOP OF EXISTING ROOF RIDGE+/- 22'-10 1/2"26'-7"DEMO WORK POCHE LEGEND - DEMO LANDSCAPE DEMO NIC COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:54:31 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtDEMOLITION - EXTERIOR ELEVATIONS - COURTYARD 05/14/2019 - PERMIT SET D.202 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE: 3/32" = 1'-0" DRAWING REF: A.401a6ADEMOLITION ELEVATION - EAST COURTYARD SCALE: 3/32" = 1'-0" DRAWING REF: A0066BDEMOLITION ELEVATION - WEST COURTYARD SCALE: 3/32" = 1'-0" DRAWING REF: A4233EDEMOLITION ELEVATION - SOUTH COURTYARD SCALE: 3/32" = 1'-0" DRAWING REF: D.1113CDEMOLITION ELEVATION - NORTH COURTYARD KEYNOTES 02.41.16.01 REMOVE COLUMNS AND CONCRETE FOOTINGS. REFER TO STRUCTURAL DRAWINGS FOR DETAILS. 02.41.19.50 REMOVE PORTE COCHERE & PORTE COCHERE LIGHTING. REFER TO ELECTRICAL DRAWINGS FOR DETAILS 02.41.19.51 REMOVE ROOF FACIA AND GUTTERS TO EXTEND SHOW. 02.41.19.52 REMOVE DOWN SPOUTS AND DISCONETCT FOR EXISTING TO REMAIN UNDERGROUND DRAINAGE 02.41.19.53 REMOVE FINISH AND SUBSTRATE TO EXTEND SHOWN 02.41.19.63 REMOVE WALLS AND ROOF AT REAR ENTRANCE. 02.41.19.65 REMOVE EXTERIOR GRADE WALL SCONE AND PREP TO RECEIVE NEW. REFER TO ELECTRICAL DRAWINGS FOR DETAILS 02.41.19.66 REMOVE TERRACOTTA ROOF SHINGLES AND STORE FOR REUSE AND REPAIRS. EXISTING ROOF DECK TO REMAIN 02.41.19.67 REMOVE TERRACOTTA ROOF SHINGLES AND STORE FOR REUSE AND REPAIRS. REMOVE ROOF DECK AND TRUSSES AS REQUIRED FOR NEW CONSTRUCTION 02.41.19.69 PREPARE AS REQUIRED EXISTING TO REMAIN EIFS, TRIMS, FASCIAS, GUTTERS, RAIN LEADERS, HANDRAILS, GUARDRAILS, PTAC COVERS ETC TO RECEIVE NEW FINISH 31.00.00.A NATURAL GRADE - AS PER GRADING PLAN DATED 10/25/86 BY SANDIS AND ASSOCIATES INC. ENGINEERS, SURVEYORS AND PLANNERS A 07/03/2019 PRELIMINARY REVIEW - REVISION C 11/20/2019 BUILDING PERMIT REVIEW - REVISION #3 D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 D D D D 02/21/2020 1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 02.41.19.66 02.41.19.52 02.41.19.56 1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" T.O. PLATTE 26' -9 3/4" HIGH EAVE 30' -9 3/4" LOW EAVE 28' -3 3/4" 02.41.19.67 02.41.19.53 02.41.19.51 02.41.19.70 02.41.19.70 1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" T.O. PLATTE 26' -9 3/4" HIGH EAVE 30' -9 3/4" LOW EAVE 28' -3 3/4" 02.41.19.53 02.41.19.51 1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" T.O. PLATTE 26' -9 3/4" HIGH EAVE 30' -9 3/4" LOW EAVE 28' -3 3/4" 02.41.19.69 02.41.19.69 D 1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" T.O. PLATTE 26' -9 3/4" HIGH EAVE 30' -9 3/4" LOW EAVE 28' -3 3/4" 02.41.19.63 02.41.19.59 02.41.19.63 02.41.19.70 02.41.19.7002.41.19.70 1ST FLOOR 0' -0" 2ND FLOOR 9' -3" 3RD FLOOR 18' -7" 02.41.19.50 02.41.19.51 02.41.19.53 DEMO WORK POCHE LEGEND - DEMO LANDSCAPE DEMO NIC COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/21/2020 11:54:34 AMC:\Users\mgodfrey\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgodfrey.rvtDEMOLITION WALL SECTIONS 05/14/2019 - PERMIT SET D.301 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA KEYNOTES 02.41.19.50 REMOVE PORTE COCHERE & PORTE COCHERE LIGHTING. REFER TO ELECTRICAL DRAWINGS FOR DETAILS 02.41.19.51 REMOVE ROOF FACIA AND GUTTERS TO EXTEND SHOW. 02.41.19.52 REMOVE DOWN SPOUTS AND DISCONETCT FOR EXISTING TO REMAIN UNDERGROUND DRAINAGE 02.41.19.53 REMOVE FINISH AND SUBSTRATE TO EXTEND SHOWN 02.41.19.56 REMOVE BAY WINDOWS 02.41.19.59 SALVAGE AUTOMATIC DOOR OPENER / CARD READER DOOR HARDWARE 02.41.19.63 REMOVE WALLS AND ROOF AT REAR ENTRANCE. 02.41.19.66 REMOVE TERRACOTTA ROOF SHINGLES AND STORE FOR REUSE AND REPAIRS. EXISTING ROOF DECK TO REMAIN 02.41.19.67 REMOVE TERRACOTTA ROOF SHINGLES AND STORE FOR REUSE AND REPAIRS. REMOVE ROOF DECK AND TRUSSES AS REQUIRED FOR NEW CONSTRUCTION 02.41.19.69 PREPARE AS REQUIRED EXISTING TO REMAIN EIFS, TRIMS, FASCIAS, GUTTERS, RAIN LEADERS, HANDRAILS, GUARDRAILS, PTAC COVERS ETC TO RECEIVE NEW FINISH 02.41.19.70 EXISTING TO REMAIN WINDOW AND/OR DOOR. KEEP AND PROTECT DURING CONSTRUCTION SCALE: 1/4" = 1'-0" DRAWING REF: A.2122ADEMOLITION - LOBBY - WALL SECTION SCALE: 1/4" = 1'-0" DRAWING REF: A.2113BDEMOLITION - FRONT ENTRANCE - WALL SECTION SCALE: 1/4" = 1'-0" DRAWING REF: A.2145BDEMOLITION - FRONT ENTRANCE ROOF - WALL SECTION SCALE: 1/4" = 1'-0" DRAWING REF: A.2112BDEMOLITION - SIDE ENTRANCE - WALL SECTION SCALE: 1/4" = 1'-0" DRAWING REF: A.2116BDEMOLITION - REAR ENTRANCE - WALL SECTION SCALE: 1/4" = 1'-0" DRAWING REF: A.2124ADEMOLITION - LOBBY - WALL SECTION A 07/03/2019 PRELIMINARY REVIEW - REVISION D 02/07/2020 BUILDING PERMIT REVIEW - REVISION #4 02/21/2020 1. PROVIDE WORK IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL ORDINANCES, AND AS APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION. 2. OBTAIN PERMITS AND PAY SUCH FEES AS MAY BE NECESSARY FOR INSPECTIONS, TESTS, AND OTHER SERVICES NECESSARY FOR THE COMPLETION OF THE WORK. 3. PROVIDE LABOR, MATERIAL, AND OTHER SERVICES AS MAY BE NECESSARY TO PROVIDE A COMPLETE AND FUNCTIONING SYSTEM. 4. NOTIFY THE ARCHITECT/ENGINEER AND RESOLVE ANY ISSUES EXPERIENCED DURING THE COURSE OF THE WORK PRIOR TO EXECUTION OF THE WORK. 5. PRODUCTS SPECIFIED IN THE DRAWINGS BY MANUFACTURER AND/OR MODEL NUMBER ARE NOT LIMITED TO THE NAMED MANUFACTURER. PROVIDE PRODUCTS BY THE NAMED MANUFACTURER OR EQUIVALENT PRODUCTS BY OTHER MANUFACTURERS 6. SUBMIT SHOP DRAWINGS FOR THE FOLLOWING ITEMS: A. LIGHT FIXTURES B. PANELBOARDS / CIRCUIT BREAKERS C. SAFETY SWITCHES D. TRANSFORMERS E. WIRING DEVICES F. CONDUCTORS G. CONDUIT H. ALL OTHER ITEMS SPECIFIED BY MODEL NUMBER ON DRAWINGS 7. SHOP DRAWINGS MUST BE APPROVED BY ENGINEER PRIOR TO PURCHASE. IF A SUBSTITUTION IS PROPOSED, BE PREPARED TO PROVIDE SAMPLES FOR EVALUATION. 8. PROVIDE MATERIAL WITHIN ONE YEAR OF MANUFACTURE, BEARING A U.L. LABEL, AND LISTED FOR ITS INSTALLED APPLICATION. 9. PROVIDE MAJOR COMPONENTS OF THE ELECTRICAL SYSTEM BY THE SAME MANUFACTURER. 10. USE MOUNTING HEIGHTS INDICATED ON THE LEGEND EXCEPT WHERE INDICATED ON THE DRAWINGS. MOUNTING HEIGHTS ARE MEASURED FROM THE MIDDLE OF WALL MOUNTED DEVICES AND FROM THE BOTTOM OF PENDENT MOUNTED DEVICES. 11. ASSEMBLE, HANG, AND CONNECT LIGHTING FIXTURES FURNISHED COMPLETE WITH SOCKETS, TRIM HANGERS, SUPPORTS, ETC, AS REQUIRED FOR A COMPLETE INSTALLATION. MOUNT LIGHT FIXTURES SUPPORTED INDEPENDENTLY OF SUSPENDED CEILING COMPONENTS. 12. PROVIDE "LOCKING" TYPE DEVICES ON CIRCUIT BREAKERS CONNECTED TO EMERGENCY LIGHTING, NIGHT LIGHTING, FIRE ALARM, AND SECURITY SYSTEMS. 13. IN FINISHED SPACES: FLUSH MOUNT LIGHT SWITCHES, RECEPTACLES, AND TELECOMMUNICATIONS OUTLETS, ROUTE RACEWAYS CONCEALED. 14. PROVIDE MOTOR OVERLOAD DEVICES IN STARTERS BASED ON NAMEPLATE RATING ON THE MOTORS BEING INSTALLED. 15. PROVIDE "HACR" TYPE CIRCUIT BREAKERS FOR CIRCUITS THAT SERVE HEATING, AIR CONDITIONING, OR REFRIGERATION EQUIPMENT. 16. PROVIDE MINIMUM #10 NEUTRAL CONDUCTOR FOR MULTI-WIRE RECEPTACLE BRANCH CIRCUITS. 17. PROVIDE SPLICES IN OUTLET OR JUNCTION BOXES ONLY. 18. PROVIDE UPDATED TYPE WRITTEN CIRCUIT DIRECTORY IN PLASTIC SLEEVE FOR EACH PANELBOARD AFFECTED BY THE WORK. 19. PROVIDE U.L. APPROVED FIRE STOP SYSTEMS FOR PENETRATIONS THROUGH FIRE AND SMOKE PARTITIONS TO MAINTAIN THE RATING OF THE PARTITION. 20. BOX-IN DEVICES ON FIRE/SMOKE PARTITIONS WITH FIRE RATED MATERIAL. 21. PROVIDE "AS-BUILT" DRAWINGS TO THE OWNER AT CONTRACT CLOSEOUT. 22. GUARANTEE WORK AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER OWNER ACCEPTANCE. 23. PERFORM ALL WORK IN ACCORDANCE WITH CALIFORNIA NATIONAL ELECTRIC CODE (2014), UNIFORM STATEWIDE BUILDING CODE (2012), ADA STANDARDS FOR ACCESSIBLE DESIGN (2010), AND CONSTRUCTION AND PROFESSIONAL SERVICES MANUAL, REV 0 (2013). 24. CONTRACTOR SHALL COMPLY WITH AND MAINTAIN A COPY OF CALIFORNIA STATE FIRE PROTECTION CODE (2012) AND NFPA 241-2000 "STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS" ON SITE. 25. NOTIFY CONSTRUCTION MANAGER, OWNER , FIRE DEPARTMENT, AND AUTHORITY HAVING JURISDICTION A MINIMUM OF SEVEN DAYS PRIOR TO ANY FIRE ALARM OR SPRINKLER SYSTEM SERVICE INTERRUPTION. PROVIDE FIRE WATCH IN ACCORDANCE WITH CALIFORNIA STATEWIDE FIRE PREVENTION CODE (2012), PARAGRAPH 901.7. SERVICE INTERRUPTIONS SHALL BE CONFINED TO TIMES WHEN THE BUILDING IS NORMALLY UNOCCUPIED. 1. PROJECT DESCRIPTION: EXTERIOR RENOVATION 2. APPLICABLE CODES: CALIFORNIA BUILDING CODE, 2016 CALIFORNIA ELECTRICAL CODE, 2016 EDITION CALIFORNIA ENERGY CODE, 2016 EDITION CALIFORNIA GREEN BUILDING CODE 2016 EDITION CUPERTINO MUNICIPAL CODE 3. EXISTING USE GROUP: A-3 / B / R-1 (NO CHANGE) 4. CONSTRUCTION CLASSIFICATION:TYPE VA ( NO CHANGE) 5. NUMBER OF STORIES: 3 6. BUILDING HEIGHT: 44' - 6" 1. DEMOLITION DRAWINGS ARE PROVIDED AS REFERENCE ONLY. DEMOLITION DRAWINGS ARE BASED ON NON-DESTRUCTIVE FIELD INVESTIGATION AND EXISTING DRAWINGS. 2. VISIT THE PROJECT SITE AND BECOME FAMILIAR WITH EXISTING FIELD CONDITIONS PRIOR TO PROCEEDING WITH THE WORK. 3. CLEAN AND REPAIR ALL EQUIPMENT INDICATED FOR REUSE OR SALVAGE. 4. DISPOSE OF, IN A LEGAL MANNER, ALL MATERIALS INDICATED FOR REMOVAL AND NOT INDICATED FOR REUSE OR SALVAGE. 5. MAINTAIN CONTINUITY OF EXISTING BRANCH CIRCUITS AND FEEDERS NOT INDICATED FOR REMOVAL BUT MAY BE DISTURBED BY THE WORK. REROUTE CIRCUITS AS REQUIRED DUE TO THE WORK. 6. EXISTING CONDUIT MAY BE ABANDONED IN THE WALLS, FLOOR SLAB, AND BELOW GRADE ONLY. REMOVE CONDUITS TO THE SURFACE OF THE W ALL/FLOOR AND PATCH. 7. REMOVE UNUSED CABLING AND CONDUCTORS ALL THE WAY BACK TO THE SOURCE. DESCRIPTION CARD READER, MOUNT +46" AFF, PROVIDE 3/4" EMPTY CONDUIT TO ACCESSIBLE ABOVE CEILING SPACE SYMBOL CR DESCRIPTION LIGHT FIXTURE LIGHT FIXTURE, WALL MOUNT BOLLARD SYMBOL SYMBOL DESCRIPTION BRANCH CIRCUIT HOMERUN, HATCH MARKS INDICATE TYPE AND NUMBER OF CONDUCTORS, DASHED LINES INDICATE UNDER FLOOR/GROUND ROUTING, PROVIDE 3#12 IN 3/4" CONDUIT UNLESS OTHERWISE INDICATED. INDICATES PHASE CONDUCTOR INDICATES NEUTRAL CONDUCTOR INDICATES GROUNDING CONDUCTOR JUNCTION BOX, CEILING ADA PUSHBUTTON J RELATED DOCUMENTS DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 01 SPECIFICATIONS, APPLY. 260513 - CONDUCTORS AND CABLES 1. PROVIDE COPPER CONDUCTORS, NEMA WC/ICEA S-95-658 TYPE THHN/THWN-2, TYPE UF, AND TYPE SO. 2. PROVIDE SOLID CONDUCTORS FOR #10 AWG AND SMALLER, STRANDED FOR # 8 AWG AND LARGER. 3. COLOR CODE ALL CONDUCTORS. 260526 - GROUNDING AND BONDING 1. PROVIDE 3/4" DIA X 10'-0" COPPER CLAD GROUND RODS. 2. PROVIDE INSULATED GROUNDING CONDUCTORS WITH ALL FEEDER AND BRANCH CIRCUITS. 260529 - HANGERS AND SUPPORTS 1. PROVIDE HOT DIP GALVANIZED STEEL SLOTTED SUPPORT SYSTEMS WITH MFMA-4 FACTORY FABRICATED COMPONENTS FOR FIELD ASSEMBLY. 2. PROVIDE STEEL HANGERS, CLAMPS, AND ASSOCIATED FITTINGS FOR CONDUIT AND CABLE SUPPORT. 3. ATTACHMENTS 3.1 WOOD - LAG SCREWS. 3.2 CONCRETE - EXPANSION ANCHORS. 3.3 MASONRY - TOGGLE TYPE BOLTS. 3.4 STEEL - BEAM CLAMPS. 3.5 LIGHT STEEL - SHEET METAL SCREWS. 260533 - RACEWAYS AND BOXES 1. METAL CONDUIT 1.1 GRC - COMPLY WITH ANSI C80 AND UL 6. 1.2 EMT - COMPLY WITH ANSI C80.3 AND UL 797. 1.3 FMC - COMPLY WITH UL 1; ZINC-COATED STEEL. 1.4 LFMC - FLEXIBLE STEEL CONDUIT WITH PVC JACKET, COMPLY WITH UL 360. 1.5 FITTINGS - COMPLY WITH FB 1 AND UL 514B. 1.6 FITTING FOR EMT - STEEL SETSCREW. 2. NON-METALLIC CONDUIT 2.1 PVC, SCHEDULE 40 - COMPLY WITH NEMA TC 2 AND UL 651. 3. APPLICATIONS 3.1 OUTDOORS EXPOSED USE GRC, UNDERGROUND USE PVC. 3.2 INDOORS EXPOSED USE GRC, CONCEALED USE EMT. 3.3 CONNECTION TO VIBRATING EQUIPMENT USE LFMC OR FMC. 3.4 PROVIDE MINIMUM 3/4" RACEWAYS. 3.5 PROVIDE PULL STRING IN ALL EMPTY CONDUITS. 260553 - IDENTIFICATION 1. PROVIDE LAMINATED ACRYLIC PLASTIC SIGNS FOR ALL EQUIPMENT, ENGRAVED LEGEND WITH BLACK LETTERS ON WHITE FACE, PUNCHED OR DRILLED FOR MECHANICAL FASTENERS. 2. PROVIDE SIGNS DESIGNATING EQUIPMENT IDENTIFICATIONS, SYSTEM VOLTAGE AND PHASE, AND PPE WARNING. 3. FOR EXTERIOR APPLICATIONS PROVIDE UV STABILIZED SIGNS. 265116 - FLUORESCENT INTERIOR LIGHTING 1. COMPLY WITH UL 1598 AND ANSI C81.61. 2. PROVIDE ELECTRONIC BALLASTS, UL 935, ANSI C82.11, CLASS A SOUND RATING, 10% THD, 42KHz OPERATING FREQUENCY, BALLAST FACTOR: 0.88 OR HIGHER, 0.95 POWER FACTOR OR HIGHER. 3. EMERGENCY FLUORESCENT POWER UNIT - INTERNAL TYPE, MODULAR BATTERY-INVERTER TO OPERATED ONE LAMP AT 1100 LUMEN OUTPUT, SEALED NI-CAD BATTERY. 4. LAMPS - 3500 DEGREE K, 20,000 HOURS AVERAGE LIFE, CRI: 85 OR HIGHER. 265119 - LED INTERIOR LIGHTING 1. COMPLY WITH NEMA LE 4 AND ANSI C79.1 AND C81.61. 2. MINIMUM CRI: 80, CCT: 3000 DEGREES K, L70 LAMP LIFE: 50,000 HOURS. 265617 - FLUORESCENT EXTERIOR LIGHTING 1. COMPLY WITH UL 1598 AND ANSI C81.61. 2. PROVIDE ELECTRONIC BALLASTS, UL 935, ANSI C82.11, CLASS A SOUND RATING, 10% THD, 42KHz OPERATING FREQUENCY, BALLAST FACTOR: 0.88 OR HIGHER, 0.95 POWER FACTOR OR HIGHER. 265619 - LED EXTERIOR LIGHTING 1. COMPLY WITH NEMA LE 4 AND ANSI C79.1 AND C81.61. 2. MINIMUM CRI: 80, CCT: 3000 DEGREES K, L70 LAMP LIFE: 50,000 HOURS. COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 1:11:28 PM C:\Users\skruyne\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Electrical_Exterior_R18_skruyne.rvtLEGEND, SPECS 05/14/2019 - PERMIT SET E.001 2.180648.0 GENERAL NOTES PROJECT INFORMATIONGENERAL DEMOLITION NOTES SECURITY LEGEND LIGHTING LEGEND POWER LEGEND ABBREVIATIONS ELECTRICAL SPECIFICATIONS ELECTRICAL DRAWING LIST DRAWING NUMBER DRAWING TITLE E.001 LEGEND, SPECS E.101 GROUND FLOOR - DEMOLITION E.102 GROUND FLOOR - NEW WORK E.201 ELEVATIONS E.202 ELEVATIONS NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NO. NUMBER P/BD PANELBOARD PR PRESENT TO REMAIN PRI PRIMARY PVC POLYVINYL CHLORIDE PWR POWER RCPT RECEPTACLE RL RELOCATED SEC SECURITY SW SWITCH SWBD SWITCHBOARD TELECOM TELECOMMUNICATIONS TV TELEVISION TVSS TRANSIENT VOLTAGE SURGE SUPRESSOR UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY V VOLTAGE W/ WITH XFER TRANSFER XFMR TRANSFORMER EM EMERGENCY EQ EQUIPMENT FA FIRE ALARM FAAP FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FC FOOT CANDLE FT FEET FVNR FULL VOLTAGE NON-REVERSING G GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTING GFI GROUND FAULT INTERRUPTING GND GROUND HP HORSEPOWER IAW IN ACCORDANCE WITH ILTG INTERIOR LIGHTING IN INCHES KCMIL KILO CIRCULAR MILLS KVA KILOVOLT AMPS KW KILOWATTS KWH KILOWATT HOURS LED LIGHT EMITTING DIODE LTG LIGHTING LTS LIGHTS MCC MOTOR CONTROL CENTER MISC MISCELLANEOUS MTD MOUNTED MTR MOTOR N NEUTRAL 1P SINGLE POLE 1PH SINGLE PHASE 2P TWO POLE 3P THREE POLE 3PH THREE PHASE A AMPERES A/V AUDIO / VISUAL AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AIC AMPERE INTERRUPTING CAPACITY AL ALUMINUM AMP AMPERE AUTO AUTOMATIC AWG AMERICAN WIRE GAUGE BFC BELOW FINISHED CEILING BFG BELOW FINISHED GRADE C CONDUIT C/T CURRENT TRANSFORMER CATV CABLE TELEVISION CB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISION CF COMPACT FLUORESCENT CKT CIRCUIT CU COPPER DEMO DEMOLITION DISC DISCONNECT ELEC ELECTRICAL ELTG EXTERIOR LIGHTING LIGHTING FIXTURE SCHEDULE TYPE MANUFACTURER MODEL VOLTAGE LAMP INPUT LOAD MOUNTING COMMENTSQTY WATTS TYPE BG EATON LIGHTING EON-B1-LED-B2-4000-UNV-T4-DI MELV-BK-42-EDGE 120 V 1 16 W LED 16 VA BOLLARD W1 EATON LIGHTING 673-16-WP-I3/830-UNV-MB 120 V 1 20 W LED 20 VA WALL Z102 EATON LIGHTING LDSQ4B20D010TR-EU4B1020804 0-4LSBQ1MB-HB26 120 V 1 22 W LED 22 VA RECESSED 05/14/2019 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA CRCR CRCRCRJ J 26.1826.18 26.22 TYPICAL 26.1 26.19 TYPICAL 26.19 TYPICAL 26.19 TYPICAL 26.19 TYPICAL 26.1 26.19 TYPICAL 26.23 TYPICAL 26.24 26.24 TYPICAL TYPICAL 26.19 TYPICAL 26.1 26.34 26.34 26.34 26.2 26.2 COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 1:11:32 PM C:\Users\skruyne\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Electrical_Exterior_R18_skruyne.rvtGROUND FLOOR - DEMOLITION 05/14/2019 - PERMIT SET E.101 2.180648.0 KEYNOTES 26.1 REMOVE EXISTING LIGHT FIXTURE; RETAIN EXISTING CIRCUIT FOR REUSE 26.2 REMOVE EXISTING RECEPTACLE; RETAIN EXISTING CIRCUIT FOR REUSE. 26.18 REMOVE EXISTING LIGHT FIXTURES AND ALL ASSOCIATED CONDUIT AND WIRING LOCATED AT PORTE COCHERE. TURN OVER EXISTING FIXTURES TO OWNER. 26.19 REMOVE EXISTING BOLLARD. REUSE EXISTING CONDUIT, WIRING, CIRCUIT, AND CONTROLS FOR REPLACEMENT BOLLARD. CONTRACTOR TO FIELDS VERIFY. TURN OVER EXISTING FIXTURE TO OWNER. 26.22 REMOVE EXISTING LIGHT FIXTURES AND RELOCATE AS SHOWN ON NEW WORK PLAN E102. CLEAN AND RELAMP FIXTURES PRIOR TO REINSTALLING. 26.23 REMOVE EXISTING SCONCE. REUSE EXISTING CONDUIT, WIRING, AND CONTROLS FOR REPLACEMENT. 26.24 REMOVE EXISTING BALCONY LIGHT. REUSE EXISTING CONDUIT, WIRING, AND CONTROLS FOR REPLACEMENT SCONCE. TURN OVER EXISTING FIXTURE TO OWNER. 26.34 DISCONNECT PUSHBUTTON MOTORIZED DOOR AND RELOCATE AS SHOW ON NEW WORK PLAN E102 SCALE: 3/32" = 1'-0"6A 1ST FLOOR LIGHTING PLAN DEMO 05/14/2019 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA REF.DWJ CRCR CRCRCRJ J JCRJ J J E.201 5A E.201 6B E.2024A E.202 6C Z102 Z102 Z102 Z102 Z102 Z102 Z102 Z102Z102 Z102 Z102 Z102 Z102 Z102 Z102 Z102 BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BGBGBG 26.12 TYPICAL 26.12 TYPICAL TYPICAL TYPICAL TYPICAL 26.20 26.20 26.20 26.20 TYPICAL 26.20 26.17 26.17 26.17 TYPICAL TYPICAL 26.16 26.11 26.10 TYPICAL 26.14 26.15 26.11 26.11 E.102 3E BG BG BG BG BG BGBG 26.9 26.35 26.35 26.35 26.17 26.37 26.37 26.38 26.37 TYPICAL W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1W1W1 W1W1 W1 W1W1W1 Z102 Z102 Z102 26.17 26.17 Z102 Z102 26.17 W1 W1 Z102 26.17 Z102 26.17 BG 26.44 BG 26.44 BG 26.44 BG 26.44 BG 26.44 BG 26.44 C C C C C C 26.9 26.8 26.7 26.21 26.17 Z102 Z102 COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.211/12/2019 10:34:55 AM C:\Users\slebow\Documents\Revit Files\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Electrical_Exterior_R18_slebow.rvtGROUND FLOOR - NEW WORK 05/14/2019 - PERMIT SET E.102 2.180648.0 106050 N. WOLF RD, CUPERTINO CA 95014 COURTYARD BY MARRIOT - SAN JOSE CUPERTINO, CA SCALE: 3/32" = 1'-0"6A 1ST FLOOR LIGHTING PLAN SCALE: 1/8" = 1'-0" DRAWING REF: E.1023E1ST FLOOR LIGHTING PLAN - FRONT STAIR CASE C 11/20/2019 BUILDING PERMIT REVIEW - REVISION #3 PR PR PR PR PR KEYNOTES 26.16 PROVIDE CONNECTION TO SIGNAGE BACKLIGHTING. COORDINATE ALL FINAL CONNECTIONS WITH EQUIPMENT SUPPLIED. 26.17 PROVIDE 4" SQUARE FIXTURE, EATON LIGHTING AS INDICATED. 26.20 PROVIDE ONE FOR ONE REPLACEMENT OF EXISTING FIXTURE WITH NEW FIXTURE AS SHOWN. REUSE EXISTING CIRCUIT AND CONTROLS. BOLLARD ORIENTATION SHALL BE TOWARDS NEAREST PATHWAY. 26.21 CIRCUIT NEW PUSHBUTTON MOTORIZED DOOR TO SPARE 20A BREAKER IN EXISTING PANEL IN CLOSEST CLOSET ; FIELD VERIFY LOCATION. SEE ARCHITECTURE DRAWINGS FOR PUSHBUTTON MOUNTING HEIGHTS AND LOCATIONS. 26.35 RECONNECT PUSHBUTTON MOTORIZED DOOR TO EXISTING CIRCUIT SERVING THIS AREA. FIELD VERIFY EXACT LOCATION 26.37 RECONNECT TO EXISTING CIRCUIT AND CONTROLS SERVING THIS AREA. 26.38 CONNECT TO 20A 120V EXISTING CIRCUIT SERVING AREA ON SECOND FLOOR FOR SIGNAGE. FIELD VERIFY EXACT LOCATION. 26.44 PROVIDE NEW FIXTURE AS SHOWN. REUSE NEAREST EXISTING BOLLARD CIRCUIT AND CONTROLS. BOLLARD ORIENTATION SHALL BE TOWARDS NEAREST PATHWAY. FIELD VERIFY LOAD DOES NOT EXCEED EXISTING BREAKER RATING.UK KEYNOTES 26.7 CIRCUIT NEW EXTERIOR EGRESS LIGHTING TO SPARE 20A BREAKER IN EXISTING PANEL IN CLOSEST CLOSET; FIELD VERIFY LOCATION. PROVIDE EXTERIOR LIGHTING CONTROLS TO MATCH EXISTING. 26.8 REINSTALL EXISTING CARD READER. EXTEND ALL WIRING AND CONTROLS TO NEW LOCATION. SEE ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS AND LOCATION. 26.9 PROVIDE ONE FOR ONE REPLACEMENT OF EXISTING FIXTURE WITH NEW. TYPICAL ALL FLOORS. REUSE EXISTING CIRCUIT AND CONTROLS. 26.10 REINSTALL EXISTING LIGHTS. EXTEND EXISTING CIRCUIT AND WIRING TO NEW LOCATIONS. REUSE EXISTING CIRCUIT AND CONTROLS. 26.11 NEW STRIP LIGHTING UNDER ROOF. SEE ELEVATIONS ON E201, E202, AND ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 26.12 PROVIDE ONE FOR ONE REPLACEMENT OF EXISTING FIXTURE WITH NEW FIXTURE AS SHOWN. TYPICAL ALL FLOORS. REUSE EXISTING CIRCUIT AND CONTROLS. REPLACE FIXTURES ON BOTH COURTYARD BALCONIES AND BUILDING PERIMETER BALCONIES. 26.14 EXTEND ORIGINAL LIGHTING CIRCUIT AND CONTROLS AND RECONNECT TO NEW FIXTURES. 26.15 CIRCUIT IN SPARE IN PANEL LOCATED IN CLOSEST CLOSET; FIELD VERIFY. TIE INTO EXISTING EXTERIOR LIGHTING CONTROL SYSTEM.C 11/22/2019 26.43 COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.211/12/2019 10:35:00 AM C:\Users\slebow\Documents\Revit Files\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Electrical_Exterior_R18_slebow.rvtGROUND FLOOR - SITE PHOTOMETRICS 05/14/2019 - PERMIT SET E.103 2.180648.0 106050 N. WOLF RD, CUPERTINO CA 95014 COURTYARD BY MARRIOT - SAN JOSE CUPERTINO, CA A 07/03/2019 PRELIMINARY REVIEW - REVISION C 11/20/2019 BUILDING PERMIT REVIEW - REVISION #3 SCALE: 1/16" = 1'-0"6A GROUND FLOOR - SITE PHOTOMETRICS KEYNOTES 26.43 EXISTING POLE FIXTURES CALCULATED USING EQUIVALENT MODERN POLE FIXTURE OF SAME MANUFACTURER. LOCATION AND MODEL BASED ON EXISTING DRAWINGS. CONTRACTOR TO FIELD VERIFY LIGHTING REQUIREMENTS. 11/22/2019 SITE BOUNDARY LINE COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.22/12/2020 1:53:54 PM C:\Users\slebow\Documents\Revit Files\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Electrical_Exterior_R18_slebow.rvtGROUND FLOOR - SITE BOUNDARY PHOTOMETRICS 05/14/2019 - PERMIT SET E.104 2.180648.0 106050 N. WOLFE RD, CUPERTINO CA 95014 COURTYARD BY MARRIOT - SAN JOSE CUPERTINO, CA D 02/14/2019 BUILDING PERMIT REVIEW - REVISION #4 SCALE: 1/16" = 1'-0"6A GROUND FLOOR - SITE BOUNDARY PHOTOMETRICS GENERAL NOTES 1. SITE BOUNDARY PHOTOMETRIC CALCULATION PERFORMED ONLY WITH NEW LIGHTING FIXTURES. EXISTING FIXTURES ARE NOT INCLUDED IN SITE BOUNDARY PHOTOMETRIC CALCULATION. D 02/12/2020 26.13 26.13 26.13 26.38 26.16 26.13 26.12 TYPICAL COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 1:11:48 PM C:\Users\skruyne\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Electrical_Exterior_R18_skruyne.rvtELEVATIONS 05/14/2019 - PERMIT SET E.201 2.180648.0 KEYNOTES 26.12 PROVIDE ONE FOR ONE REPLACEMENT OF EXISTING FIXTURE WITH NEW FIXTURE AS SHOWN. TYPICAL ALL FLOORS. REUSE EXISTING CIRCUIT AND CONTROLS. REPLACE FIXTURES ON BOTH COURTYARD BALCONIES AND BUILDING PERIMETER BALCONIES. 26.13 PROVIDE EXTERIOR LED STRIP LIGHTING ALONG NEW WALL, EATON - NEORAY - "S122-DRL030XXX-0035-1-U-ED-4-B", LENGTH AT REQUIRED, RECESSED GYP WITH FLANGE. CONNECT TO AVAILABLE CIRCUIT AND PANEL AND EXISTING EXTERIOR LIGHTING CONTROLS IN ELECTRICAL CLOSEST; CONTRACTOR FIELD VERIFY. 26.16 PROVIDE CONNECTION TO SIGNAGE BACKLIGHTING. COORDINATE ALL FINAL CONNECTIONS WITH EQUIPMENT SUPPLIED. 26.38 CONNECT TO 20A 120V EXISTING CIRCUIT SERVING AREA ON SECOND FLOOR FOR SIGNAGE. FIELD VERIFY EXACT LOCATION. SCALE: 3/32" = 1'-0" DRAWING REF: E.1025AELEVATION - WEST SCALE: 3/32" = 1'-0" DRAWING REF: E.1026BELEVATION - SOUTH 05/14/2019 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA 26.13 26.12 TYPICAL COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 1:11:59 PM C:\Users\skruyne\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Electrical_Exterior_R18_skruyne.rvtELEVATIONS 05/14/2019 - PERMIT SET E.202 2.180648.0 SCALE: 3/32" = 1'-0" DRAWING REF: E.1024AELEVATION - EAST SCALE: 3/32" = 1'-0" DRAWING REF: E.1026CELEVATION - NORTH KEYNOTES 26.12 PROVIDE ONE FOR ONE REPLACEMENT OF EXISTING FIXTURE WITH NEW FIXTURE AS SHOWN. TYPICAL ALL FLOORS. REUSE EXISTING CIRCUIT AND CONTROLS. REPLACE FIXTURES ON BOTH COURTYARD BALCONIES AND BUILDING PERIMETER BALCONIES. 26.13 PROVIDE EXTERIOR LED STRIP LIGHTING ALONG NEW WALL, EATON - NEORAY - "S122-DRL030XXX-0035-1-U-ED-4-B", LENGTH AT REQUIRED, RECESSED GYP WITH FLANGE. CONNECT TO AVAILABLE CIRCUIT AND PANEL AND EXISTING EXTERIOR LIGHTING CONTROLS IN ELECTRICAL CLOSEST; CONTRACTOR FIELD VERIFY. 05/14/2019 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA ST-1 FC-1 EF-4 EF-3 EF-2 EF-1 NOT FOR CONSTRUCTION COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.27/2/2019 5:54:44 PMC:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt3D VIEWS 05/14/2019 - PERMIT SET G.001 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE:6A EXTERIOR PERSPECTIVE - FRONT EXTERIOR COLOR FINISH LEGEND A A 07/03/2019 PRELIMINARY REVIEW - REVISION 07/16/2019 ST-1 FC-1 EF-4 EF-3 EF-2 EF-1 NOT FOR CONSTRUCTION COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.27/2/2019 5:54:56 PMC:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Arch_R18_mgarbacz.rvt3D VIEWS 05/14/2019 - PERMIT SET G.002 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA SCALE:6A EXTERIOR PERSPECTIVE - REAR EXTERIOR COLOR FINISH LEGEND A A A A 07/03/2019 PRELIMINARY REVIEW - REVISION 07/16/2019 ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL,P.O.BOX400,RICHMOND,VA23218-0400TEMPLATE2018.23/21/201910:57:57AMC:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbMSanJose-CupertinoCA_Arch_R18_mgarbacz.rvtEXISTING CONDITIONS & DEMOLITION PLAN 05/14/2019 - PERMIT SET L.001 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA B 09/05/2019 PRELIMINARY REVIEW- REVISION #02 C 11/20/2019 BUILDING PERMIT REVIEW- REVISION #3 ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL,P.O.BOX400,RICHMOND,VA23218-0400TEMPLATE2018.23/21/201910:57:57AMC:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbMSanJose-CupertinoCA_Arch_R18_mgarbacz.rvtPLANTING PLANL.002 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA 05/14/2019 - PERMIT SET B 09/05/2019 PRELIMINARY REVIEW- REVISION #02 C 11/20/2019 BUILDING PERMIT REVIEW- REVISION #3 ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL,P.O.BOX400,RICHMOND,VA23218-0400TEMPLATE2018.23/21/201910:57:57AMC:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbMSanJose-CupertinoCA_Arch_R18_mgarbacz.rvtLANDSCAPE DETAILS, NOTES, & SCHEDULEL.003 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA 05/14/2019 - PERMIT SET B 09/05/2019 PRELIMINARY REVIEW- REVISION #02 C 11/20/2019 BUILDING PERMIT REVIEW- REVISION #3 ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL,P.O.BOX400,RICHMOND,VA23218-0400TEMPLATE2018.23/21/201910:57:57AMC:\Users\mgarbacz\Documents\2.180648.0_SDG-CYbMSanJose-CupertinoCA_Arch_R18_mgarbacz.rvtPLANT IMAGE BOARD (EX. & PROPOSED)L.004 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA 05/14/2019 - PERMIT SET B 09/05/2019 PRELIMINARY REVIEW- REVISION #02 C 11/20/2019 BUILDING PERMIT REVIEW- REVISION #3 ABBREVIATIONS - PLUMBING CO CLEANOUT (E) EXISTING OST OVERFLOW STORM ST STORM PIPING ELBOW, TURNING DOWN ELBOW, TURNING UP PIPE CAP POINT OF CONNECTION, NEW TO EXISTING REMOVE TO THIS POINT NEW PIPING OR EQUIPMENT (SHOWN DARK) EXISTING PIPING OR EQUIPMENT TO REMAIN (SHOWN LIGHT) EXISTING PIPING OR EQUIPMENT TO BE REMOVED PLUMBING LEGEND RD-3A 666 SF (E) 6" ST CO AT BASE (E) 6" ST RD-3B 666 SF CAP PIPE CAP PIPE CO AT BASE EXISTING STORM BELOW GRADE EXISTING STORM BELOW GRADE RD-3A 694 SF RD-3A, 502 SF RD-3A, 436 SF RD-3A, 436 SF 22.19 22.19 RD-3B 694 SF RD-3B 502 SF RD-3B, 436 SF RD-3B, 436 SF 22.20 22.20 22.20 22.20 CAP PIPE 3" ST 3" ST CO AT BASE CO AT BASE 3" ST 22.19 TIE INTO EXISTING STORM PIPING. PROVIDE CLEANOUT AT BASE OF PIPING IN WALL. TIE INTO EXISTING STORM PIPING. PROVIDE CLEANOUT AT BASE OF PIPING IN WALL. POCHE LEGEND NOT IN CONTRACT DEMO WORK APPLICABLE CODES: BUILDING CODE: 2016 CALIFORNIA BUILDING CODE, VOLUME 1 & 2 PLUMBING CODE: 2016 CALIFORNIA PLUMBING CODE 2016 CALIFORNIA GREEN BUILDING STANDARD CODE CUPERTINO MUNICIPAL CODE COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 9:19:44 AM C:\Users\rshearon\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Plumbing_R18_rshearon.rvtNEW WORK ROOF PLAN 05/14/2019 - PERMIT SET P.114 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA STORM & STORM OVERFLOW PIPING (ABOVE SLAB/GRADE)ST & OST CAST IRON HUBLESS PIPE, TYPE DWV, ASTM A74, ASTM A888, CISPI 301 WITH MATCHING FITTINGS. JOINT SURFACES SHALL BE CLEAN AND FREE FROM MOISTURE. HEAVY DUTY SHIELDED COUPLINGS MEETING CISPI 310, WITH STAINLESS STEEL SHIELD AND NEOPRENE GASKET. STORM & STORM OVERFLOW PIPING (BELOW SLAB/GRADE)ST PVC, TYPE DWV, ASTM D 2665, WITH MATCHING FITTINGS. JOINT SURFACES SHALL BE CLEAN AND FREE FROM MOISTURE. A PURPLE PRIMER THAT COMFORMS WITH ASTM F 656 SHALL BE APPLIED. SOLVENT CEMENT NOT PURPLE IN COLOR AND CONFORMING TO ASTM D 2564 SHALL BE APPLIED TO ALL JOINT SURFACES. THE JOINT SHALL BE MADE WHILE CEMENT IS WET AND SHALL BE IN ACCORDANCE WITH ASTM D 2588. SYSTEM SYMBOL PIPE, FITTING AND JOINTS PLUMBING MATERIAL SCHEDULE PLUMBING ROOF DRAIN SCHEDULE TYPE BODY MATERIAL COMBINATION FLASHING RING AND GRAVEL STOP DOME MATERIAL UNDERDECK CLAMP SUMP RECEIVER WATER DAM REMARKS RD-3A CAST IRON REQUIRED CAST IRON REQUIRED REQUIRED NOT REQUIRED JAY R SMITH SERIES 1010-R-C-CID RD-3B CAST IRON REQUIRED CAST IRON REQUIRED NOT REQUIRED REQUIRED JAY R SMITH SERIES 1080-WD025-C-CID SCALE: 3/32" = 1'-0"6A NEW WORK ROOF PLAN KEYNOTES 22.19 4"X3" DOWNSPOUT BOOT AT ARCHITECTURAL DOWNSPOUT. TIE INTO EXISTING STORM PIPING BELOW GRADE. DOWNSPOUT BOOT TO BE JAY R. SMITH MFG. CO. NO. 1785. EXTEND NEW STORM PIPING TO EXISTING UNDERGROUND STORM. 22.20 DOWNSPOUT NOZZLE, ZURN NO. Z199. 05/14/2019 (E) 6" ST (E) 6" ST EXISTING STORM BELOW GRADE EXISTING STORM BELOW GRADE 22.12 22.12 22.12 22.12 POCHE LEGEND NOT IN CONTRACT DEMO WORK COPYRIGHT 2019 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. ISSUE PROJECT NUMBER 1 A23456ABCDE 134562 BCDEBASKERVILL, P.O. BOX 400, RICHMOND, VA 23218-0400TEMPLATE 2018.25/14/2019 9:19:47 AM C:\Users\rshearon\Documents\2.180648.0_SDG-CYbM San Jose-Cupertino CA_Plumbing_R18_rshearon.rvtDEMOLITION ROOF PLAN 05/14/2019 - PERMIT SET PD.114 2.180648.0 10605 N WOLFE RD, CUPERTINO, CA 95014 COURTYARD BY MARRIOTT - SAN JOSE CUPERTINO, CA KEYNOTES 22.12 REMOVE DOWNSPOUT. SCALE: 3/32" = 1'-0"6A DEMOLITION ROOF PLAN 05/14/2019 Corporate Headquarters 1500 North Mantua Street P.O. Box 5193 Kent, OH 4240-5193 330-673-5685 Toll Free 1-800-828-8312 Fax: 330-673-0860 Regional Office 6005 Capistrano Ave. Suite A Atascadero, CA 93422 Direct: 503-880-3818 Lori.Murphy@Davey.com September 4th, 2019 Ashley Seay Baskervill 101 S. 15th St. Suite 200 Richmond, VA 23219 aseay@baskervill.com 804.728.3015 RE: Tree Inventory and Arborist Report for Courtyard Hotel in Cupertino, CA Dear Ms. Seay, Thank you for contracting with Davey Resource Group Inc.(DRG)regarding the above project.In support of your objectives DRG is pleased to provide you with the attached report for the planned project. A DRG International Society of Arboriculture (ISA)Certified Arborist (#PD-2444A)conducted the site assessment of sixteen trees that are planned for removal prior to landscaping upgrades at the Courtyard Hotel in Cupertino, California.The trees were assessed for location,size,current condition,and overall health to assist with design considerations for landscape upgrades and tree removals.The attached report can be used to assist with tree removal permitting. The survey determined the following: ▪Sixteen (16) trees were evaluated ▪Seven (7)distinct species were identified.The most common species was southern live oak (​Quercus virginiana) ▪Tree condition was rated from good to critical ▪All trees fall under protected status as defined by the City of Cupertino, CA (​Ch. 14.18.050, ​C) ▪New landscape installation will require hand digging to reduce impacts to roots of retained trees Please feel free to contact me if you would like more information or have any questions. Sincerely, Lori Murphy - Consulting Arborist Davey Resource Group Inc. Certified Arborist #WE-7844-AM 916-899-7917 TREE INVENTORY   AND ARBORIST REPORT   Courtyard Hotel   10605 N. Wolfe Rd.  Cupertino, CA    September 2019      Courtyard Hotel Cupertino, CA 2    September​ 2019 ​ Tree Inventory and Arborist Report   Courtyard Hotel, 10605 N. Wolfe Rd.,   Cupertino, California      Prepared for    Ashley Seay   Baskervill   101 S. 15th St., Suite 200   Richmond, VA 23219        September 2019    Prepared by:    Davey Resource Group  A Division of The Davey Tree Expert Company  1500 North Mantua Street  Kent, OH 44240    Contact:     Lori Murphy  Certified Arborist #WE-7844AM  ISA Tree Risk Assessment Qualified  www.daveyresourcegroup.com     Lori Murphy  ISA Arborist #WE 7844 AM  ISA Tree Risk Assessment Qualified  www.daveyresourcegroup.com          Notice of Disclaimer Inventory data provided by Davey Resource Group is based on visual recording at the time of inspection. Visual records do not include testing or analysis and do not include aerial or subterranean inspection. Davey Resource group is not responsible for discovery or identification of hidden or otherwise non-observable risks. Records may not remain accurate after inspection due to variable deterioration of inventoried material and site disturbance. Davey Resource Group provides no warranty with respect to the fitness of the urban forest for any use or purpose whatsoever or for future outcomes of the inventoried trees. Courtyard Hotel Cupertino, CA 3    September​ 2019 Contents Summary 5 Introduction 5 Assignment 5 Limits of Assignment 5 Purpose and Use of Report 5 Observations 6 Methods 6 Site Observations 6 Analysis and Discussion 6 Conclusion and Recommendations 7 Landscape Comments 7 Appendix A – Tree Inventory and Condition Assessment 8 Table 1. Tree Inventory July 2019 8 Table 2. Condition Assessment August 2019 9 Appendix B – Photos 10 Appendix C - Area Map 24 Courtyard Hotel Cupertino, CA 4    September​ 2019 Summary In August 2019,Davey Resource Group,Inc.(DRG)was contracted by Ms.Ashley Seay of Baskervill to conduct a tree inventory and develop an arborist report for sixteen (16)client-identified trees slated for removal to facilitate site and landscape upgrades at the Courtyard by Marriott Hotel in Cupertino, CA. An International Society of Arboriculture (ISA)Certified Arborist from DRG (​PD-2444A​)conducted an evaluation of the trees on August 22nd and 28th,2019.The data set was collected as GIS-based tree inventory and trees were assessed by their location,size,current condition,and overall health.The evaluations determined,based on visual inspection,tree condition ratings ranged from good (11 trees)to fair (3 trees).Two redwood trees were in critical condition. Only trees identified by the project contact were assessed. Introduction Assignment Baskervill architects are coordinating with Courtyard Hotel to implement landscape and site upgrades around the hotel.DRG received a landscape plan of the site that detailed those trees slated for removal.The trees are protected under Cupertino Municipal Code Chapter 14.18.050-C as part of an approved development and require a permit for removal. This inventory establishes the quantity and condition of trees slated for removal.The condition of each tree was visually assessed and photographed.The property managers are planning landscape upgrades and proactive removals on the site and replacing these with more appropriate species.This tree inventory is intended to help apply for necessary tree removal permits.By proactively managing trees adjacent to buildings and other assets,managers are planning for the necessary steps to create a plan for a sustainable low-maintenance landscape. Limits of Assignment Many factors can limit specific and accurate data when performing evaluations of trees,their conditions,and potential for failure or response to site disturbances.No soil or tissue testing was performed.All observations were made from the ground on August 22nd and 28th,2019,and no soil excavation to expose roots was performed.The determinations and recommendations presented here are based on current data and conditions that existed at the time of the evaluation and cannot be a predictor of the ultimate outcome for the evaluated trees in the future. Purpose and Use of Report The scope of work includes only inventoried trees as identified by the client.The purpose is to help create a sustainable landscape through strategic removal and replacement with appropriate species.This report will be used to facilitate tree removal permitting with the City of Cupertino. This report outlines strategies to help property managers interpret tree data collected and provide long-term management recommendations.Effective care of this tree population requires the management plan to address potential impacts and to the building and hardscape.The planned upgrades provide long term strategies for ensuring the safety and overall health of the trees on site. Overall,trees are an important component of the urban ecosystem.Property managers have an opportunity to steward this resource proactively in order to maintain safety and property values and guide maintenance planning which will enhance and preserve the beauty and livability within the surrounding community.With appropriate management the trees will be vital assets to the property for many years to come. Courtyard Hotel Cupertino, CA 5    September​ 2019 Observations Methods Only a visual inspection was used to develop the findings,conclusions,and recommendations found in this report.For each tree,diameter at breast height (DBH)was collected using the following methods.All trees identified by the client as planned for removal were collected. Shrubs were not required to be included in the inventory. Data collection also included height estimation,canopy radius estimation,a visual assessment of tree condition, structure,and health,and a photographic record of trees and site conditions.To assign condition,numerical values were assigned to grade the attributes of the roots,trunk,branches,and foliage,including structure and health,and averaged to obtain an overall condition rating.No physical inspection of the upper canopy,sounding,root crown excavation, resistance drilling, or other technologies were used in the evaluation of the trees. Site Observations The inventory took place at the The Courtyard Hotel located at 10605 N.Wolfe Rd.north of Interstate 280 in Cupertino,California.Many planting locations next to the building are narrow and limiting the growth of the trees.The site is level and trees are irrigated. Tree Observations Sixteen (16)trees were assessed within the project area including seven distinct species.The most common species is southern live oak (​Quercus virginiana​,7 trees),with camphor tree (​Cinnamomum camphora,​2 trees),coast redwood (​Sequoia sempervirens​,2 trees),and Eastern redbud (​Cercis canadensis​,2 trees)were the next most prevalent species. There is only one specimen each of Australian willow (​Geijera parviflora​),Austrian black pine (​Pinus thunbergiana​), and cherry plum (​Prunus cerasifera​).Tree condition ratings for most trees was good (11 trees)and three (3)trees are in fair condition.The two redwoods are in critical condition due to a serious decline in health.Tree diameters ranged from 2”to 15”with an average of 11”and heights ranged from 10’to 35’with an average of 26’.The tree inventory is a mixed age population from young to mature. The completeTree Inventory and Condition Assessment can be found in Appendix A and tree photographs can be found in ​Appendix B​. Analysis and Discussion Preliminary designs were provided and reviewed for this Arborist Report.Renovation includes upgrades to the existing landscape including removal of 16 trees.Two of the trees (#15 &#16)are in critical condition,and two (#1 &#2)will have significant impacts from entryway construction.One tree (#3)will be impacted by a bike storage installation and the remaining trees are outgrowing available planting space.The trees next to the building need room to expand without need for excessive pruning to keep them from causing damage.Trees planted in inappropriate locations for their species ultimately require significant maintenance as they continue to grow to their genetic potential and are repeatedly pruned,sometimes multiple times per year.For example,southern live oak is an evergreen tree with a growth rate of two to three feet per year.The mature stature is over fifty feet (50’)feet tall and sixty feet (60’)wide. In order to be a sustainable landscape asset,this tree requires a minimum of 30’clearance in all directions from the trunk.   Courtyard Hotel Cupertino, CA 6    September​ 2019 Conclusion and Recommendations Based on visual evaluations and review of site plans,it was determined that 16 trees are slated for removal.The majority of assessed trees are in good to fair condition and two are in serious decline.Most trees are planted in growth limiting spaces.While canopy loss is a concern,removing these trees and replacing them with species that are more suitable to the available grow space will promote the health and vigor of the trees to be retained.DRG recommends removal of all sixteen subject trees and re-planting with suitable species that will not overwhelm buildings and crowd adjacent trees.Suitable species include fruitless olive (​Olea europaea ‘Monher’),upright Streetspire oak (​Quercus robur x ​alba ‘JFS-KW1QX’)​,and crape myrtle (​Lagerstroemia indica​).With thoughtful consideration to available space and species choices and planning for the mature height,spread,and root growth of the trees will help to ensure that the tree population can sustainably reach maturity and provide the social and environmental benefits intended.Conducting this tree inventory highlighted some opportunities to mitigate or relieve negative impacts through the removal of certain trees. Landscape Comments Careful installation of new landscaping by hand digging will reduce impacts to trees that will be retained.Best Management Practices (BMP)in tree preservation recommend impacting no more than twenty five percent of a tree’s root system.A ten foot minimum excavation free zone around all existing trees should be observed to help ensure maximum survivability of these trees.Also,a five foot clearance from the trunk of all newly installed trees is recommended to reduce competition for rooting space.As is true of all landscape plans,proper hydrozoning is necessary for sustainable landscapes. Courtyard Hotel Cupertino, CA 7    September​ 2019 Appendix A – Tree Inventory and Condition Assessment Table 1. Tree Inventory August 2019 Tree # DBH Common Name Botanical Name Condition Rating Height Notes 1 15 Camphor tree Cinnamomum camphora Good 35 Hardscape damage 2 14 Camphor tree Cinnamomum camphora Fair 35 Stressed 3 6 Cherry plum Prunus cerasifera Fair 16 Poor structure, root damage 4 15 Southern live oak Quercus virginiana Good 35 One-sided 5 15 Southern live oak Quercus virginiana Good 35 One-sided 6 14 Southern live oak Quercus virginiana Good 35 One-sided 7 14 Southern live oak Quercus virginiana Fair 35 Basal decay 8 8 Japanese black pine Pinus thunbergiana Good 10 9 14 Australian willow Geijera parviflora Good 25 Crowded location 10 12 Southern live oak Quercus virginiana Good 25 Signs of stress 11 12 Southern live oak Quercus virginiana Good 25 One-sided 12 12 Southern live oak Quercus virginiana Good 25 Signs of stress 13 2 Eastern redbud Cercis canadensis Good 12 14 3 Eastern redbud Cercis canadensis Good 12 15 10 Coast redwood Sequoia sempervirens Critical 35 Serious decline 16 7 Coast redwood Sequoia sempervirens Critical 25 Serious decline Courtyard Hotel Cupertino, CA 8    September​ 2019 Table 2. Condition Assessment August 2019 Tree Number Root Health Root Structure Trunk Health Trunk Structure Scaffold Health Scaffold Structure Twigs Condition Foliage Condition Condition rating 1 3 3 3 3 3 3 2.5 3 73 2 3 3 3 3 2 3 2 3 69 3 2.5 2.5 3 2 3 2 3 3 70 4 3 3 3 3 3 3 3 3 75 5 2.5 3 3 3 3 3 3 3 73 6 2.5 3 3 3 3 3 3 3 73 7 2 3 2 3 3 3 3 3 69 8 2 3 3 3 3 3 2.5 2.5 72 9 3 3 3 3 3 3 3 3 75 10 3 3 3 3 3 3 2.5 3 73 11 3 3 3 3 3 3 3 3 75 12 3 3 3 3 3 3 3 3 75 13 3 3 3 3 3 3 3 3 75 14 3 3 3 3 3 3 3 3 75 15 1 1 .5 2 .5 2 0 .5 9 16 .5 1 .5 2 .5 2 0 0 9 Courtyard Hotel Cupertino, CA 9    September​ 2019 Appendix B – Photos Photo 1. Camphor tree #1 is damaging curb Courtyard Hotel Cupertino, CA 10    September​ 2019 Photo 2. Camphor tree #2 is showing signs of stress Courtyard Hotel Cupertino, CA 11    September​ 2019 Photo 3. Tree #3 has poor branch structure Photo 4. Tree #3 leans Courtyard Hotel Cupertino, CA 12    September​ 2019 Photo 5. Tree #4 is growing too close to building Courtyard Hotel Cupertino, CA 13    September​ 2019 Photo 6. Tree #5 is one sided Courtyard Hotel Cupertino, CA 14    September​ 2019 Photo 7. Tree #6 is one sided Courtyard Hotel Cupertino, CA 15    September​ 2019 Photo 8. Tree #7 has unbalanced and off-center canopy Courtyard Hotel Cupertino, CA 16    September​ 2019 Photo 9. Tree #8 has an excessive lean Courtyard Hotel Cupertino, CA 17    September​ 2019 Photo 10. Tree #9 is growing very close to building Courtyard Hotel Cupertino, CA 18    September​ 2019 Photo #11. Tree #10 has unbalanced and off-center canopy Courtyard Hotel Cupertino, CA 19    September​ 2019 Photo 12. Tree #11 is one-sided Courtyard Hotel Cupertino, CA 20    September​ 2019 Photo 13. Tree #12 is unbalanced and one-sided Courtyard Hotel Cupertino, CA 21    September​ 2019 Photo 14. Tree #14 is planned for removal and replacement. Courtyard Hotel Cupertino, CA 22    September​ 2019 Photo 15. Trees #15 and #16 are in serious decline. Courtyard Hotel Cupertino, CA 23    September​ 2019 Appendix C - Area Map Courtyard Hotel Cupertino, CA 24    September​ 2019