HomeMy WebLinkAboutAH Packet 8-22-2019CITY OF CUPERTINO
ADMINISTRATIVE HEARING
AGENDA
10300 Torre Avenue, City Hall Conference Room C
Thursday, August 22, 2019
5:00 PM
ROLL CALL
APPROVAL OF MINUTES
1.Subject: Draft Minutes of June 13, 2019
Recommended Action: approve or modify the Draft Minutes of June 13, 2019
Draft Minutes of June 13, 2019
ORAL COMMUNICATIONS
This portion of the meeting is reserved for persons wishing to address the members on any matter not
on the agenda. Speakers are limited to three (3) minutes. In most cases, State law will prohibit the
members from making any decisions with respect to a matter not listed on the agenda
WRITTEN COMMUNICATIONS
PUBLIC MEETING
2.Subject: Architectural and Site Approval Permit to allow for an 80 square foot
first-floor addition to an existing duplex.
Application No(s).: ASA-2019-01; Applicant(s): Anthony Estrella (Ponce residence);
Location: 22821 Medina Ln
APN#342-30-011
Recommended Action: That the Hearing Officer adopt the draft resolution to:
1) Find that the proposed project is exempt from CEQA; and
2) Approve the Architectural and Site Approval Permit.
Administrative Officer's decision final unless appealed
Staff Report
1 - Draft Resolution for ASA-2019-01
2 - Plan Set
OLD BUSINESS
NEW BUSINESS
STAFF AND COMMITTEE REPORTS
Page 1
Administrative Hearing Agenda August 22, 2019
ADJOURNMENT
In compliance with the Americans with Disabilities Act (ADA), anyone who is planning to attend the
next meeting who is visually or hearing impaired or has any disability that needs special assistance
should call the City Clerk's Office at 408-777-3223, 48 hours in advance of the meeting to arrange for
assistance. Upon request, in advance, by a person with a disability, meeting agendas and writings
distributed for the meeting that are public records will be made available in the appropriate alternative
format. Also upon request, in advance, an assistive listening device can be made available for use
during the meeting.
Any writings or documents provided to a majority of the members after publication of the agenda will
be made available for public inspection. Please contact the City Clerk’s Office in City Hall located at
10300 Torre Avenue during normal business hours.
IMPORTANT NOTICE: Please be advised that pursuant to Cupertino Municipal Code 2.08.100
written communications sent to the Cupertino City Council, Commissioners or City staff concerning a
matter on the agenda are included as supplemental material to the agendized item. These written
communications are accessible to the public through the City’s website and kept in packet archives. You
are hereby admonished not to include any personal or private information in written communications to
the City that you do not wish to make public; doing so shall constitute a waiver of any privacy rights
you may have on the information provided to the City .
Members of the public are entitled to address the members concerning any item that is described in the
notice or agenda for this meeting, before or during consideration of that item. If you wish to address the
members on any other item not on the agenda, you may do so during the public comment .
Page 2
Cupertino, CA 95014
(408) 777-3308
ACTION MINUTES OF THE REGULAR MEETING OF
THE ADMINISTRATIVE HEARING HELD ON June 13, 2019
ROLL CALL
Hearing Officer present: Ben Fu, Acting Community Development Director
Staff present: Ellen Yau, Associate Planner
Applicant(s) present: Steven Dauber, property owner
APPROVAL OF MINUTES:
1.May 23, 2019
The minutes of May 23, 2019 were approved as written
POSTPONEMENTS/REMOVAL FROM CALENDAR:
None
ORAL COMMUNICATIONS:
None
WRITTEN COMMUNICATIONS:
None
PUBLIC MEETING ITEMS:
2. Application No.(s): ASA-2019-03
Applicant:Steve Dauber (Dauber residence)
Location: 10367 Heney Creek Pl APN# 342-48-027
Architectural and Site approval to allow a 77 square foot addition and modifications to the façade
material for a single family residence located in a Planned Development Zone
Administrative Hearing Officer’s decision final unless appealed.
Staff member Yau addressed the Hearing Officer. The project site is located in a Planned
Development that was originally approved in 1977. The property owner would like to update
the entire façade of the home and enclose a balcony and a rear alcove area. This will increase
the square footage by 77 square feet. The Planned Development has a zoning designation that
includes Hillside Intent. This designation means that the home’s exterior should be
harmonious with the surrounding landscape in color and textures. The homeowner is
proposing rock veneer, HardiePlank siding and painted neutral tones over stucco. The current
exterior is largely wood siding so the HardiePlank is very similar in design, but more durable.
2 Administrative Hearing
June 13, 2019
The proposed exterior changes are still in keeping with the look and style of the neighborhood.
The project was reviewed by other City departments, notices were sent to the neighbors and
the property owner also reached out to his neighbors. Because the project site is the rear home
on a tree covered flag lot, the visual impacts are minimal.
The hearing officer asked for clarification that the height and footprint of the home were not
changing. He also asked for the distance between the balcony (to be enclosed) and the adjacent
home. Staff member Yau stated that it was about 50 feet. He asked the property owner about
the outreach he conducted with his neighbors. Mr. Dauber said he emailed all of the 37 homes
in the subdivision to ask how they felt about replacing some of the wood siding with stucco.
He received 10 responses, 9 of these were in favor. His immediate neighbor was unable to
attend tonight’s meeting, but does not have any issues with the façade changes.
The Hearing Officer opened the public comment period.
There were no speakers.
The Hearing Officer closed the comment period.
The Hearing Officer thanked the applicant for working with Staff through the process. He
appreciated the work that the architect did to provide drawings that were easy to read and
informational. The Hearing Officer supported the project as it maintains the original intent of
the Planned Development’s style and preserved the overall feel of the neighborhood.
DECISION: The application was approved by the Hearing Officer per the Draft Resolution
ADJOURNMENT
Respectfully submitted:
_____/s/Beth Ebben
Beth Ebben
Deputy Board Clerk
ADMINISTRATIVE HEARING STAFF REPORT
Agenda Date: August 22, 2019
Subject
Architectural and Site Approval Permit to consider allowing an 80 square foot first-floor
addition to an existing duplex; (Application No(s).: ASA-2019-01; Applicant: Anthony
Estrella; Location: 22821 Medina Lane; APN(s): 342-30-011)
Recommended Action
That the Hearing Officer adopt the draft resolution (Attachment 1) to:
1. Find that the proposed project is exempt from CEQA; and
2. Approve the Architectural and Site Approval Permit.
Discussion
Project Data:
General Plan Planning Area Inspiration Heights Neighborhood
General Plan Designation Low Density / Medium Density (5-10 DU/Ac.)
Zoning Designation R2-4.25
Density:Existing Proposed
10 DU/acre 10 DU/acre (no change)
Net Lot Area 9,064 square feet (0.21 acres)
Site Development Allowed/Required Existing Proposed
Lot Coverage (max 40%)3,625 sf
3,345 sf
(36.9%)
3,425 sf
(37.8%)
1st Floor Setbacks
Front 20’21’No Change
Rear (greater of 20’ or 20% of
the lot depth)22’-11”20’-9”No Change
Side: (greater of 6’ or 20% of lot
width at front setback line)
13.8’ combined and
no side less than 6’
Left: 8’-1”No Change
Right: 6’-11”No Change
ASA-2019-01 22821 Medina Lane August 22, 2019
Page 2
Consistency
General Plan Yes
Zoning Yes
Environmental Assessment Categorically Exempt per Section 15301 (Class 1) of
the California Environmental Quality Act (CEQA)
Background:
Site Description
The existing duplex is located in the
Inspiration Heights neighborhood
near the intersection of Medina Lane
and El Prado Way (Figure 1). The
property abuts a planned
development of attached
townhomes to the north, and
additional duplex properties to the
east, south, and west.
The existing duplex was initially
constructed in 1969 with a total
existing area of 3,345 square feet. The
existing living space for Unit “A” is
1,421 square feet while Unit “B” is
1,123 square feet. The duplex also
includes an 801 square feet three-car
garage.
Analysis:
Conformance with General Plan and Zoning
The proposed project is consistent with the General Plan Land Use Designation of
Low/Medium Density (5-10 units/acre), which allows a maximum of two (2) dwelling
units based on the net lot area, and the zoning designation of Residential Duplex (R-2).
Architectural and Site Approval
The applicant, Anthony Estrella, representing the property owner, Robert Ponce, is
proposing an 80 square foot addition and minor interior remodel to Unit “B” of the
existing duplex (see plan set – Attachment 2). The proposed project will increase the
living area of the smaller unit from 1,123 square feet to 1,203 square feet. Total lot
Figure 1. Site Aerial
ASA-2019-01 22821 Medina Lane August 22, 2019
Page 3
coverage on site will increase from 36.9% to 37.8%. The R-2 Zoning Ordinance allows a
maximum lot coverage of 40% for duplex units. Therefore, the proposed project does not
exceed the maximum allowable lot coverage.
The addition for Unit “B” is proposed within the interior courtyard area of the property,
to the west of the existing unit and to the north of the existing third car garage space.
Approximately 19 square feet of the third car garage space will be converted to habitable
area for the addition of the proposed bedroom. This garage space is larger than the
required interior dimensions for a single car garage per the Municipal Code. Therefore,
after conversion, the garage would continue to conform with the requirements of the
Parking Ordinance.
The addition will not impact existing setbacks or result in significant visual impacts to
surrounding properties. The architecture and material of the proposed addition are
designed to match the existing home and be compatible with the character of the
neighborhood by maintaining a similar building form and the existing total building
height. Additionally, exterior finishes of the addition will be consistent with the existing
building and will use stucco, similar roofing material, and windows.
While no other exterior or site modifications are proposed as part of the project, the
project does propose minor interior remodeling, including elimination of an interior
connection from the third garage space, relocation of a coat closet and washer and dryer
facilities to accommodate the addition of the new bedroom.
Environmental Review
This project is categorically exempt from the requirements of the California
Environmental Quality Act (CEQA) per Section 15301 – Existing Facilities.
Public Noticing And Community Outreach
The following table is a brief summary of the noticing for this project:
Notice of Public Hearing Agenda
Site Signage (at least 10 days prior to
hearing)
9 notices mailed to property owners
adjacent to the project site (at least 10
days prior to the hearing)
Posted on the City's official notice
bulletin board (five days prior to
hearing)
Posted on the City of Cupertino’s
Web site (five days prior to hearing)
No comments have been received at the time of production of this staff report.
Permit Streamlining Act
ASA-2019-01 22821 Medina Lane August 22, 2019
Page 4
This project is subject to the Permit Streamlining Act (Government Code Section 65920 –
65964). The City has complied with the deadlines found in the Permit Streamlining Act.
Project Received: March 12, 2019; Deemed Incomplete: April 1, 2019
Revisions Received: May 13, 2019; Deemed Incomplete: June 12, 2019
Revisions Received: June 24, 2019; Deemed Complete: July 11, 2019
Since this project is Categorically Exempt, the City has 60 days (until September 11, 2019)
to make a decision on the project.
Conclusion
Staff recommends approval of the Architectural and Site Approval permit, since the plans
and conditions of approval address all concerns related to the proposed project.
Additionally, the findings for approval of the proposed project, consistent with Chapter
19.168 of the Cupertino Municipal Code, may be made as follows:
1. The proposal, at the proposed location, will not be detrimental or injurious to property
or improvements in the vicinity, and will not be detrimental to the public health,
safety, general welfare, or convenience;
The applicant is proposing an addition of 80 square feet to an existing duplex. The proposed
project complies with the allowed use of the property and does not intensify the use of the
property. The addition will be located in an existinginterior courtyard area of the property.
The addition is designed to be consistent with the existing duplex by maintaining the
building height, building form, and exterior finishes for stucco, roofing material, and
windows. No other exterior or site modifications are proposed as part of the scope of work.
All of the proposed changes are minor improvements to the existing duplex and will not be
detrimental to the public health, safety, general welfare or convenience.
2. The proposal is consistent with the purposes of Chapter 19.168: Architectural and Site
Review of the Cupertino Municipal Code, the General Plan any specific plan, zoning
ordinances, applicable planned development permit, conditional use permits,
variances, subdivision maps or other entitlements to use which regulate the subject
property including, but not limited to, adherence to the following specific criteria:
a) Abrupt changes in building scale should be avoided. A gradual transition related
to height and bulk should be achieved between new and existing buildings.
The square footage added to the home is minimal. The existing wall plane height of the
duplex will be maintained, and the proposed roof form will be similar to the existing roof
form. Therefore, there will not result in an abrupt change in building scale.
b) In order to preserve design harmony between new and existing buildings and in
order to preserve and enhance property values, the materials, textures and colors
ASA-2019-01 22821 Medina Lane August 22, 2019
Page 5
of new building should harmonize with adjacent development by being consistent
or compatible with design and color schemes with the future character of the
neighborhoods and purposes of the zone in which they are situated. The location,
height and materials of walls, fencing, hedges and screen planting should
harmonize with adjacent development. Unsightly storage areas, utility
installations and unsightly elements of parking lots should be concealed. The
planting of ground cover or various types of pavements should be used to prevent
dust and erosion, and the unnecessary destruction of existing healthy trees should
be avoided. Lighting for development should be adequate to meet safety
requirements as specified by the engineering and building departments, and
provide shielding to prevent spill-over light to adjoining property owners.
The proposed architectural design, materials, and finishes, will be consistent with the
existing building and harmonize with the character of the neighborhood. The project
proposes no changes to the location, height, and materials of existing fencing and
landscaping and does not propose any storage, utility units, and/or parking lots.
Furthermore, the proposal has been designed to meet the requirements of the Residential
Duplex (R-2) Ordinance.
c) The number, location, color, size, height, lighting and landscaping of outdoor
advertising signs and structures have been designed to minimize traffic hazard,
positively affect the general appearance of the neighborhood and harmonize with
adjacent development.
No signage is proposed as part of this residential project.
d) With respect to new projects within existing residential neighborhoods, new
development should be designed to protect residents from noise, traffic, light and
visually intrusive effects by use of buffering, setbacks, landscaping, walls and
other appropriate design measures.
The proposed project is not a new project. It is a single-story addition located within an
existing interior courtyard area of an existing duplex property and will not result in any
significant visual impacts to surrounding properties. The project has been designed in
accordance with the development standards of the R-2 Zoning District with the intent to
protect residents from unnecessary noise, traffic, light and visually intrusive effects.
Additionally, the materials used and architectural articulation proposed for the addition are
appropriately consistent with the existing exterior of the duplex and complements the
existing neighborhood in materials and colors. The project will not be visually intrusive or
cause noise, traffic, and light impacts to the adjacent properties.
ASA-2019-01 22821 Medina Lane August 22, 2019
Page 6
Next Steps
The permit will be effective 14 calendar days from the date of the hearing. The decision
of the Administrative Hearing Officer is final, unless appealed within 14 calendar days
from the date of the hearing. The applicant team may apply for building and/or other
permits with the City at the end of the appeal period.
This approval is valid until August 22, 2021. The applicant team may apply for a one-time
one year extension before the approval expires.
Prepared by: Erika Poveda, Assistant Planner
Reviewed and Approved for submission by:Piu Ghosh, Principal Planner
ATTACHMENTS
1. Draft Resolution for ASA-2019-01
2.Plan Set
ASA-2019-01
CITY OF CUPERTINO
10300 Torre Avenue
Cupertino, California 95014
RESOLUTION NO.
OF THE ADMINISTRATIVE HEARING OFFICER OF THE CITY OF
CUPERTINO APPROVING AN ARCHITECTURAL AND SITE APPROVAL
PERMIT TO ALLOW AN 80 SQUARE FOOT SINGLE-STORY ADDITION TO
AN EXISTING DUPLEX LOCATEDAT 22821 MEDINA LANE (APN 342-30-011)
SECTION I: PROJECT DESCRIPTION
Application No.:ASA-2019-01
Applicant:Anthony Estrella
Location:22821 Medina Lane
SECTION II: FINDINGS FOR ARCHITECTURAL AND SITE APPROVAL PERMIT:
WHEREAS, the City of Cupertino received an application for an Architectural and Site
Approval to consider allowing an approximately 80 square foot single-story addition to
an existing duplex, as described in Section I. of this Resolution; and
WHEREAS, the necessary public notices have been given as required by the Procedural
Ordinance of the City of Cupertino, and the Administrative Hearing Officer has held at
least one public meeting in regard to the application; and
WHEREAS, pursuant to the provisions of the California Environmental Quality Act of
1970 (Public Resources Code section 21000 et seq.) (“CEQA”), together with the State
CEQA Guidelines (California Code of Regulations, Title 14, Section 15000 et seq.)
(hereinafter, "CEQA Guidelines"), the City staff has independently studied the proposed
Project and has determined that the Project is exempt from environmental review
pursuant to the categorical exemption in CEQA Guidelines section 15301 for the reasons
set forth in the staff report dated July 25, 2019 and incorporated herein; and
WHEREAS, the applicant has met the burden of proof required to support said
application; and
WHEREAS, the Administrative Hearing Officer finds as follows with regard to this
application:
Resolution No.ASA-2019-01 July 25, 2019
Page 2
1.The proposed development, at the proposed location, will not be detrimental or
injurious to property or improvements in the vicinity, and will not be detrimental to
the public health, safety, general welfare, or convenience;
The applicant is proposing an addition of 80 square feet to an existing duplex. The proposed
project complies with the allowed use of the property and does not intensify the use of the
property. The addition will be located in an existing interior courtyard area of the property.
The addition is designed to be consistent with the existing duplex by maintaining the
building height, building form, and exterior finishes for stucco, roofing material, and
windows. No other exterior or site modifications are proposed as part of the scope of work.
All of the proposed changes are minor improvements to the existing duplex and will not be
detrimental to the public health, safety, general welfare or convenience.
2.The proposal is consistent with the purposes of Chapter 19.168, the General Plan
any specific plan, zoning ordinances, applicable planned development permit,
conditional use permits, variances, subdivision maps or other entitlements to use
which regulate the subject property including, but not limited to, adherence to the
following specific criteria:
a) Abrupt changes in building scale should be avoided. A gradual transition related
to height and bulk should be achieved between new and existing buildings.
The square footage added to the home is minimal. The existing wall plane height of the
duplex will be maintained, and the proposed roof form will be similar to the existing roof
form. Therefore, there will not result in an abrupt change in building scale.
b) In order to preserve design harmony between new and existing building and in
order to preserve and enhance property values, the materials, textures and colors
of new building should harmonize with adjacent development by being consistent
or compatible with design and color schemes with the future character of the
neighborhoods and purposes of the zone in which they are situated. The location,
height and materials of walls, fencing, hedges and screen planting should
harmonize with adjacent development. Unsightly storage areas, utility
installations and unsightly elements of parking lots should be concealed. The
planting of ground cover or various types of pavements should be used to prevent
dust and erosion, and the unnecessary destruction of existing healthy trees should
be avoided. Lighting for development should be adequate to meet safety
requirements as specified by the engineering and building departments, and
provide shielding to prevent spill-over light to adjoining property owners.
The proposed architectural design, materials, and finishes, will be consistent with the
existing building and harmonize with the character of the neighborhood. The project
proposes no changes to the location, height, and materials of existing fencing and
Resolution No.ASA-2019-01 July 25, 2019
Page 3
landscaping and does not propose any storage, utility units, and/or parking lots.
Furthermore, the proposal has been designed to meet the requirements of the Residential
Duplex (R-2) Ordinance.
c) The number, location, color, size, height, lighting and landscaping of outdoor
advertising signs and structures have been designed to minimize traffic hazard,
positively affect the general appearance of the neighborhood and harmonize with
adjacent development.
No signage is proposed as part of this residential project.
d) With respect to new projects within existing residential neighborhoods, new
development should be designed to protect residents from noise, traffic, light and
visually intrusive effects by use of buffering, setbacks, landscaping, walls and
other appropriate design measures.
The proposed project is not a new project. It is a single-story addition located within an
existing interior courtyard area of an existing duplex property and will not result in any
significant visual impacts to surrounding properties. The project has been designed in
accordance with the development standards of the R-2 Zoning District with the intent to
protect residents from unnecessary noise, traffic, light and visually intrusive effects.
Additionally, the proposed materials and architectural articulation are proposed to be
applied consistently throughout the exterior of the home and complements the existing
neighborhood in materials and colors. The project will not be visually intrusive or cause
noise, traffic, and light impacts to the adjacent properties.
NOW, THEREFORE, BE IT RESOLVED:
That after careful consideration of the maps, facts, exhibits, testimony, staff’s report and
presentation,and other evidence submitted in this matter, subject to the conditions which
are enumerated in this Resolution beginning on PAGE 3 thereof,:
The application for an Architectural and Site Approval, Application no. ASA-2019-01 is
hereby approved and that the subconclusions upon which the findings and conditions
specified in this resolution are based and contained in the Public Meeting record
concerning Application no. ASA-2019-01 as set forth in the Minutes of the Administrative
Hearing Meeting of July 25, 2019 and are incorporated by reference as though fully set
forth herein.
Resolution No.ASA-2019-01 July 25, 2019
Page 4
SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY
DEVELOPMENT DEPT.
1. APPROVED EXHIBITS
Approval is based on the plan set drawn by A.R.E. Design Group entitled “Ponce
Residence” consisting of seven (7) sheets,except as may be amended by conditions
in this resolution.
2. ACCURACY OF PROJECT PLANS
The applicant/property owner is responsible to verify all pertinent property data
including but not limited to property boundary locations, building setbacks,
property size, building square footage, any relevant easements and/or
construction records. Any misrepresentation of any property data may invalidate
this approval and may require additional review.
3. ANNOTATION OF THE CONDITIONS OF APPROVAL
The conditions of approval set forth shall be incorporated into and annotated on
the first page of the building plans.
4. CONSULTATION WITH OTHER DEPARTMENTS
The applicant is responsible for consulting with other departments and/or agencies
with regard to the proposed project for additional conditions and requirements. Any
misrepresentation of any submitted data may invalidate an approval by the
Community Development Department.
5. FENCES
Any changes to the fencing shall require design review with the Community
Development Department and shall comply with Cupertino Municipal Code Chapter
19.48 Fences
6. EXTERIOR BUILDING MATERIALS/TREATMENTS
Final building exterior treatment plan (including but not limited to details on exterior
color, material, architectural treatments, lighting fixtures, and/or embellishments)
shall be reviewed and approved by the Director of Community Development prior to
issuance of building permits. The final building exterior plan shall closely resemble
the details shown on the original approved plans. Any exterior changes determined
to be substantial by the Director of Community Development shall require a
modification approval with neighborhood input. Prior to issuance of building
permits, staff will review exterior material, architectural elements, and building scale
and massing to ensure quality and consistency with the approved findings prescribed
in Section II above.
Resolution No.ASA-2019-01 July 25, 2019
Page 5
7.DEMOLITION REQUIREMENTS
All demolished building and site materials shall be recycled to the maximum
extent feasible subject to the Building Official. The applicant shall provide
evidence that materials were recycled prior to occupancy.
8. GRADING AND CONSTRUCTION HOURS AND NOISE LIMITS
The applicant shall indicate compliance with the following grading and
construction hours and noise limit requirements on all demolition, construction
and grading permits, and in the construction management plan(s), unless
otherwise indicated.
a. All grading activities shall be limited to the dry season (April 15 to October 1),
unless permitted otherwise by the Director of Public works.
b. Construction hours and noise limits shall be compliant with all requirements
of Chapter 10.48 of the Cupertino Municipal Code.
c. Grading, street construction, underground utility and demolition hours for
work done more than 750 feet away from residential areas shall be limited to
Monday through Friday, 7 a.m. to 8 p.m. and Saturday and Sunday, 9 a.m. to
6 p.m. Grading, street construction, demolition or underground utility work
within 750 feet of residential areas shall not occur on Saturdays, Sundays,
holidays, and during nighttime period as defined in Section 10.48.053(b) of the
Municipal Code.
d. Construction activities shall be limited to Monday through Friday, 7 a.m. to 8
p.m. and Saturday and Sunday, 9 a.m. to 6 p.m. Construction activities are not
allowed on holidays as defined in Chapter 10.48 of the Municipal Code. Night
time construction is allowed if compliant with nighttime standards of Section
10.48 of the Cupertino Municipal Code.
e. Rules and regulations pertaining to all construction activities and limitations
identified in this permit, along with the name and telephone number of an
applicant appointed disturbance coordinator, shall be posted in a prominent
location at the entrance to the job site.
f. The applicant shall be responsible for educating all contractors and
subcontractors of said construction restrictions.
9. BAAQMD BASIC CONTROL MEASURES (DUST CONTROL)
Project shall comply with the Bay Area Quality Management District’s Basic
Construction Mitigation Measures to reduce construction fugitive dust impacts as
follows:
a.All exposed surfaces (e.g., parking areas, staging areas, soil piles, graded areas,
and unpaved access roads) shall be watered two times per day.
Resolution No.ASA-2019-01 July 25, 2019
Page 6
b.All haul trucks transporting soil, sand, or other loose material off-site shall be
covered.
c.All visible mud or dirt tracked-out onto adjacent public roads shall be removed
using wet power vacuum street sweepers at least once per day. The use of dry
power sweeping is prohibited.
d.All vehicle speeds on unpaved roads shall be limited to 15 mph.
e.All roadways, driveways, and sidewalks to be paved shall be completed as
soon as possible. Building pads shall be laid as soon as possible after grading
unless seeding or soil binders are used.
f.Idling times shall be minimized either by shutting equipment off when not in
use or reducing the maximum idling time to 5 minutes (as required by the
California airborne toxics control measure Title 13, Section 2485 of California
Code of Regulations [CCR]). Clear signage shall be provided for construction
workers at all access points.
g.All construction equipment shall be maintained and properly tuned in
accordance with manufacturer’s specifications. All equipment shall be checked
by a certified mechanic and determined to be running in proper condition prior
to operation.
h.A publicly visible sign shall be posted with the telephone number and person
to contact at the City of Cupertino regarding dust complaints. This person shall
respond and take corrective action within 48 hours. The BAAQMD phone
number shall also be visible to ensure compliance with applicable regulations.
Applicant shall indicate compliance with BAAQMD’s basic control measures on all
demolition, construction and grading permits and construction management plan(s).
10. CONSULTATION WITH OTHER DEPARTMENTS
The applicant is responsible to consult with other departments and/or agencies with
regard to the proposed project for additional conditions and requirements. Any
misrepresentation of any submitted data may invalidate an approval by the
Community Development Department.
11. INDEMNIFICATION
Except as otherwise prohibited by law, the applicant shall indemnify and hold
harmless the City, its City Council, and its officers, employees and agents (collectively,
the “indemnified parties”) from and against any claim, action, or proceeding brought
by a third party against one or more of the indemnified parties or one or more of the
indemnified parties and the applicant to attack, set aside, or void this Resolution or
any permit or approval authorized hereby for the project, including (without
limitation) reimbursing the City its actual attorneys’ fees and costs incurred in defense
of the litigation. The applicant shall pay such attorneys’ fees and costs within 30 days
Resolution No.ASA-2019-01 July 25, 2019
Page 7
following receipt of invoices from City. Such attorneys’ fees and costs shall include
amounts paid to counsel not otherwise employed as City staff and shall include City
Attorney time and overhead costs and other City staff overhead costs and any costs
directly related to the litigation reasonably incurred by City.
12. NOTICE OF FEES, DEDICATIONS, RESERVATIONS, OR OTHER EXACTIONS
The Conditions of Project Approval set forth herein may include certain fees,
dedication requirements, reservation requirements, and other exactions. Pursuant to
Government Code Section 66020(d) (1), these Conditions constitute written notice of
a statement of the amount of such fees, and a description of the dedications,
reservations, and other exactions. You are hereby further notified that the 90-day
approval period in which you may protest these fees, dedications, reservations, and
other exactions, pursuant to Government Code Section 66020(a), has begun. If you
fail to file a protest within this 90-day period complying with all of the requirements
of Section 66020, you will be legally barred from later challenging such exactions.
PASSED AND ADOPTED this 25th day of July, 2019 at a noticed Public Meeting of the
Administrative Hearing Officer of the City of Cupertino, State of California, held by the
Director of Community Development, or his or her designee, pursuant to Cupertino
Municipal Code Section 19.12.120.
ATTEST:APPROVED:
Erika Poveda Benjamin Fu
Assistant Planner Acting Director of Community Development
UNIT "A"UNIT "B"ADDITION(E) GARAGE FORUNIT "A"(E) GARAGEFOR UNIT"BDRAINSLOPE 5%DRAINSLOPE 5%DRAIN
SLOPE 5%
DRAIN
SLOPE 5%DRAINSLOPE 5%SWALEDRAIN
SLOPE 5%
DRAIN
SLOPE 5%
DRAIN
SLOPE 5%
DRAIN
SLOPE 5%(E) 100 AMPELECT. PANELUNIT BGAS METER
WATER METERUNIT BWATER METERUNIT A(E) LATERAL
(E) CLEANOUTCURB 10' P.U.E.2' P.U.E.(E) DRIVEWAY
(E) DRIVEWAY
24.5' REAR SETBACK LINE20' FRONT SETBACK LINE12734666SWALE(E) 6' HIGH
REDWOO0D FENCE
(E) 6' HIGH
REDWOO0D FENCE
(E) 6' HIGH
REDWOO0D FENCE (E) 6' HIGHREDWOO0D FENCE(E) 6' HIGH
REDWOO0D F
E
N
C
E
L=69'-5"5' W.C.E.NGUMLEMONORANGEAPPLECYPRESSCREEPE-MYRTHEYUCCA1234567Contact InformationOwner Robert Ponce 408-992-1102ApplicantAnthony Estrella 408-407-8900CONTACT DATA#SHEETSPDATESCALEDRAWNCHECKEDBYREVISIONSADDITION FOR:
Cupertino, CA
PONCE RESIDENCE
22821 Medina Lane
(408)-406-8900 BUS.
DRAFTING AND DESIGNS BY:
A.R.E. DESIGN GROUP
SAN JOSE,CALIFORNIA
715 N. FIRST ST. ste. 34
SITE PLAN 9/18/18JC12/18/18JC
711807118081804030LS8036LS5943LS
3068
4040LS3840LS266826682668506826684268
4268 356824681668
5968 SLD. DOOR
TO BE REMOVED
4040 WINDOW
TO BE REMOVED
26682668
2668 2668 DR.TO BEREMOVED51'-2"(E) GARAGE(E) MASTERBDRM(E)
MASTER
BATH (E) BEDROOM(E) LIVING ROOM(E) KITCHEN UNIT "A"(E) GARAGEFIRE PLACE TO
BE REMOVED FENCEFENCE
21'-9"7'-3"12'-4"22'-4"3'-9"
22'-8 1
16"14'-7"30'22'-9"1'-11"11'11'-9"6'-5"4'-4"10'-11"2'-6"
4'-9"51'-7"27'-1"4'-6"78'-3"AT LEAST ONE 20 AMP BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLYLAUNDRY RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHEROUTLETS. (CEC 210.11(C)(2))C)RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. (CEC210.11(C)(2))#SHEETEXDATESCALEDRAWNCHECKEDBYREVISIONSADDITION FOR:
Cupertino, CA
PONCE RESIDENCE
22821 Medina Lane
(408)-406-8900 BUS.
DRAFTING AND DESIGNS BY:
A.R.E. DESIGN GROUP
SAN JOSE,CALIFORNIA
715 N. FIRST ST. ste. 34
JC9/19/18
TAMPER RESISITANT RECEPTACLES PER CEC 406.11.ALL 125-VOLT, 15-AND 20-AMPERE RECEPTACLE SHALL BE LISTED OUTLETSMOTION TRIGGERED LIGHT W/ SWITCHWH71180711808180
4030LS8036LS5943LS
3068
4040LS3840LS(N) 4040 DBLPANE SLD. GLSWINDOW (EGRESS)2668(N) 3068
DR.2668506826684268
4268 35682668
(N) 6168 DBL.
PANE SLD. GLS
DR. (TEMP.)
3768
2668
(N) 2668
DR.R4R4R4(E) GARAGE FORUNIT B(E) MASTERBDRM(E)
MASTER
BATH 18 (E) BATH (E) LIVING ROOM(E) KITCHEN(N) BEDROOMUNIT "A"36" CONC.LANDING4'-1"3'-4"14'-2"(E) GARAGE FORUNIT "A"(N) 5068SOLID CORE DR.R42'-9"3'-10"
(N) 2468
DR.FAU3'-3"3'-2"EGRESS22"X18"ATTICACCESS(E) BEDROOMALL FAUCETS AND WATER CLOSETSARE EXISTING.3' MINEGRESS WDEXHAUST DUCTPROVIDE 100 S.I. OFOPENING AT LAUNDRYDOOR FOR MAKEUP AIRPROVIDE 100 S.I. OFOPENING AT UTILITY DOOR FORCOMBUSTION AIR TOFURNACE AND WATER HEATERALL 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS ORDEVICES INSTALLED IN DWELLING UNIT , KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVINGROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS,HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTEDARE-FAULT CIRCUIT INTERRUPTER. (CEC 210.12)AT LEAST ONE 20 AMP BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLYLAUNDRY RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHEROUTLETS. (CEC 210.11(C)(2))(E) 100 AMP ELECT. PANELUNIT BGFIGFIALL INSTALLED LUMINARIES SHALL BE HIGH EFFICACYIN ACCORDANCE WITH TABLE 150.0-AAT LEAST ONE 20 AMP BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLYLAUNDRY RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHERALL INSTALLED LUMINARIES SHALL BE HIGH EFFICACYLAUNDRYRECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. (CEC20'A) RECESSED DOWNLIGHT LUMINARIES IN CEILING SHALL BE LISTED FOR ZERO CLEARANCE, SHALL BE CERTIFIED AS AIRTIGHT (INCLUDING EXHAUST FAN HOUSINGS), SHALL BE SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINARIES HOUSING AND CEILING , SHALL NOT CONTAIN SCREW BASE SOCKETS, AND ALL LIGHT SOURCES SHALL BE MARKED WITH "JA8-2016-E" AS SPECIFIED REFERENCE JOIST APPENDIX JA8.B) ALL FORWARD PHASE SHALL BE SWITCHED SEPARATELY FROM LIGHTING SYSTEM.C) EXHAUST FAN SHALL BE SWITCHED SEPARATELY FROM LIGHTING SYSTEMD) LUMINARIES SHALL BE SWITCHED WITH READILY ACCESSIBLE CONTROLS THAT PERMIT THE LUMINARIES TO BE MANUALLY SWITCHED ON AND OFF.E) IN BATHROOMS, GARAGE, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE LUMINARIES IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR.F) DIMMERS OR VACANCY SENSORS SHALL CONTROL ALL LUMINARIES (EXCEPTIONS: LUMINARIES IN CLOSETS LESS THAN 70sp. ft. AND IN HALLWAYS)G) RESIDENTIAL OUTDOOR LIGHTING SHALL BE CONTROLLED BY A MANUAL ON AND OFF SWITCH WITH PHOTOCELL AND MOTION SENSOR(A) AIR DUCT SHALL NOT PREVENT ACCESS TO AN AREA OF THE CRAWL SPACE(B) WHERE IT IS REQUIRED TO MOVE UNDER DUCT FOR ACCESS TO ARE OF THE CRAWL SPACE A MINIMUM VERTICAL CLEARANCE OF EIGHTEEN (18") INCHES SHALL BE PROVIDED(E) CLOTHES DRYER MOISTURE EXHAUST DUCT SHALL TERMINATE OUTSIDE THE BUILDING AND HAVE A BACKDRAFT DAMPER. EXHAUST DUCT IS LIMITED TO 14'WITH TWO ELBOWS. THIS SHALL BE REDUCED 2' FOR EVERY ELBOW IN EXCESS OF TWO.SHOW MINIMUM 4" DIAMETER, SMOOTH, METAL DUCT.(D) PROVIDE MAKEUP AIR FOR CLOTHES DRYER. WHEN A CLOSET IS DESIGNED FOR THE INSTALLED OF A CLOTHES DRYER, A MINIMUM OPENING OF 100 SQUARE INCHES SHALL BE PROVIDED IN THE DOOR. (CMC 504.4.1(1))(C) SINGLE-WALL METAL PIPE SHALL NOT BE USED AS A VENT IN DWELLING AND RESIDENTIAL OCCUPANCIES PER CMC 802.7.3.CALIFORNIA CIVIL CODE ARTICLE 1101.4 AND CAL GREEN SECTION 301.1, FORALL BUILDING ALTERATIONS OR IMPROVEMENTS TO A SINGLE FAMILYRESIDENTIAL PROPERTY, EXISTING PLUMBING FIXTURES IN THE ENTIREHOUSE THAT DO NOT MEET CURRENT FLOW RATES WILL NEED TO BEUPGRADED.A) WATER CLOSETS WITH A FLOW RATE IN EXCESS OF 1.6 gpf. WILL NEED TO BE REPLACED WITH WATER CLOSETS WITH A MAXIMUM FLOW RATE OF 1.28 gpfB) SHOWER HEADS WITH A FLOW RATE GREATER THAN 2.5 GPM. WILL NEED TO BE REPLACED WITH A MAXIMUM 2.0 gpm SHOWER HEAD.C) LAVATORY AND KITCHEN FAUCETS WITH A FLOW RATE GREATER THAN 2.2 gpm WILL NEED TO BE REPLACED WITH FAUCET WITH MAXIMUM FLOW RATE OF 1.5 gpm (OR 1.8 gpm FOR KITCHEN FAUCETS).ENERGY LIGHTING REQUIREMENTSMECHANICAL NOTESPLUMBING NOTESA) MINIMUM NET CLEAR OPENABLE DIMENSION OF 24 INCHES IN HEIGHT (R310.2.1).B) MINIMUM NET CLEAR OPENABLE DIMENSION 20 INCHES IN WIDTH (R310.2.1).C) MINIMUM NET CLEAR OPENABLE DIMENSION OF 5.7 SQUARE FEET IN AREA. GRADE FLOOR ORBELOW GRADE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SQ FT (R310.2.1).D) THE BOTTOM OF THE CLEAR OPENING SHALL NOT BE GREATER THAN 44 INCHES MEASUREFROM THE FLOOR. (R310.2.2).(G) ELEMENTS OF APPLIANCES WHICH GENERATE A GLOW, SPARK, OR FLAME (SUCH ASWATER HEATER AND FURNACE) SHALL BE LOCATED A MINIMUM OF 18 INCHESABOVE GARAGE FLOOR (CMC 305.1, CPC 507.13.).WINDOW NOTESA.ROVIDE A 120V ELECTRICAL RECEPTACLE THAT IS WITHIN 3 FEET FROM THE WATERHEATER AND ACCESSIBLE TO THE WATER HEATER WITH NO OBSTRUCTIONS.B.PROVIDE A CATEGORY III OR IV VENT, OR A TYPE B VENT WITH STRAIGHT PIPE BETWEENTHE OUTSIDE TERMINATION AND THE SPACE WHERE THE WATER HEATER IS INSTALLED.C.PROVIDE A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THEBASE OF THE INSTALLED WATER HEATER, AND ALLOWS NATURAL DRAINING WITHOUTPUMP ASSISTANCE. CLARIFY ON PLAN HOW THIS WILL BE ACCOMPLISHED.D.PROVIDE A GAS SUPPLY LINE WITH A CAPACTITY OF AT LEAST 200,000 BTU/HR.INSTALLATION REQUIREMENTS FOR NEW HOT WATER HEATER(H) SINGLE-WALL METAL PIPE SHALL NOT BE USED AS A VENT IN DWELLINGSAND RESIDENTIAL OCCUPANCIES PER CMC 802.7.3(F) DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM 26 GAGE (0.48) SHEET STEEL OR OTHER APPROVED MATERIAL OR OTHER PENETRATIONS OF GARAGE/DWELLING CEILINGS AND WALLS ARE TO BE PROTECTED (R302.11, ITEM 4).(J) AIR DUCTS INSTALLED UNDER A FLOOR IN A CRAWL SPACE SHALL BE INSTALLED INACCORDANCE WITH THE FOLLOWING: (CMC 603.2)(1) SHALL NOT PREVENT ACCESS TO AN AREA OF THE CRAWL SPACE. (2) WHERE IT IS REQUIRED TO MOVE UNDER DUCTS FOR ACCESS TO AREAS OF THECRAWL SPACE A MINIMUM VERTICAL CLEARANCE OF EIGHTEEN (18) INCHESSHALL BE PROVIDED.D) ALL DOMESTIC HOT WATER SYSTEM PIPING CONDITIONS LISTED BELOW, WHETHER BURIED OR UNBURISED, MUST BE INSULATED AND THE INSULATION THICKNESS SHALL BE SELECTED FROM THE FUILD TEMPERATURE RANGED BASED ON THE THICKNESS REQUIREMENTS IN TABLE 120.3-A (CEnC 150(J)(2)) 1) THE FIRST 5 FEET OF HOT AND COULD WATER PIPES FROM THE STORAGE TANK. 2) ALL PIPING WITH A NOMINAL DIAMETER OF 34" INCH OR LARGER. 3) ALL HOT WATER PIPES FROM THE HEATING SOURCE TO THE KITCHEN FIXTURES.#SHEET1DATESCALEDRAWNCHECKEDBYREVISIONSADDITION FOR:
Cupertino, CA
PONCE RESIDENCE
22821 Medina Lane
(408)-406-8900 BUS.
DRAFTING AND DESIGNS BY:
A.R.E. DESIGN GROUP
SAN JOSE,CALIFORNIA
715 N. FIRST ST. ste. 34
JC9/19/18WATER HEATER STRAP DETAILJC1/30/19
(E) STUCCO(E) STUCCO(E) STUCCO(E) STUCCO
(E) STUCCO
(E) STUCCO (E) ROOF LINE FOR REAR UNITS NOT FRONT UNITS(E) ROOF LINE FOR FRONT UNIT14'-5"
14'-5"(E) STUCCO(E) STUCCO(E) STUCCO(E) STUCCO(E) STUCCO(E) STUCCO14'-5"
14'-5"#SHEET2DATESCALEDRAWNCHECKEDBYREVISIONSADDITION FOR:
Cupertino, CA
PONCE RESIDENCE
22821 Medina Lane
(408)-406-8900 BUS.
DRAFTING AND DESIGNS BY:
A.R.E. DESIGN GROUP
SAN JOSE,CALIFORNIA
715 N. FIRST ST. ste. 34
JC9/19/18
(N) DBL PANESL GL DR.(N) STUCCOFINISH TOMATCH (E)(E) STUCCO14'-5"(E) STUCCO(E) STUCCO(N) STUCCOFINISH TOMATCH (E)(E) STUCCO(N) DBL. PANEWINDOWTEMPTEMP13'-11"#SHEET2ADATESCALEDRAWNCHECKEDBYREVISIONSADDITION FOR:
Cupertino, CA
PONCE RESIDENCE
22821 Medina Lane
(408)-406-8900 BUS.
DRAFTING AND DESIGNS BY:
A.R.E. DESIGN GROUP
SAN JOSE,CALIFORNIA
715 N. FIRST ST. ste. 34
JC9/19/18
EXISTING FOUNDATIONFIELD VERIFYACCESS (18" X 30" MIN)
BE REMAIN)
PROVIDE CRAWL SPACE
AT OPENING (FOOTING TO
PROVIDE (N) 4X6 HEADER
CUT (E) STEM WALL TO OF UNDER FLOOR AREA(3) 5 X 14 SCREENED CRAWLSPACE VENTS TO BE 1/150(N) FTG.#5 DOWELS 16" LONGEPOXY 4" INTO (E) FTG. EMBED 12" IN EXISTING FOUNDATIONFIELD VERIFYEXISTING SLAB FOUNDATIONA4(A) FASTENERS FOR PRESERVATIVE-TREATEDWOOD SHALL BE OF HOT DIPPED ZINC-COATEDGALVANIZED STEEL, STAINLESS STEEL, SILICONBRONZE OR COPPER (R317.3.1)1) ONE-HALF-INCH DIAMETER OR GREATER STEEL BOLTS.2) PLAIN CARBON STEEL FASTENERS IN SBX/DOTAND ZINC BORATE PRESERVATIVE-TREATED WOODIN AN INTERIOR, DRY ENVIRONMENT SHALL BEPERMITTED.NAILED W/ 8d @ 6" O.C.@ ALL EDGES SUPPORTING MEMBERS.T&G APA RATED STURD-1-FLOORFLOOR SHEATING TO BE 1-1/8" & AT 12" O.C. @ ALL INTERMEDIATEFLOOR SHEATINGFOUNDATION NOTESEXCEPTIONSH
T
T
4
HT
T
4
HTT4HTT4
(N) 2X6 FLR. JST.
@ 16" OC DF#2
(N) 2X6 FLR. JST.
@ 16" OC DF#2
4X4 POST W/18X18 SQR FTG.4X4 POST W/18X18 SQR FTG.(N) FTG.#5 DOWELS 16" LONGEPOXY 4" INTO (E) FTG. EMBED 12" IN GH HANGER
@ GDR ENDS#5 DOWELS 16" LONGEPOXY 4" INTO (E) FTG. EMBED 12" IN (E) HDR(E) HDR
(E) HDR
(E) HDR
(E) HDR
(E) HDR
(E) HDR
(E) HDR
(E) HDR
(E) HDR(E) HDR(E) HDR(E) HDR(E) HDR(E) HDR(E) HDR(E) HDR(E) HDR(N) 4X12 HDR(N) 4X12 HDR
(N) 4X8 HDR
(N) 4X8 HDR (N) 4X12 HDR(N) 4X8 HDR(N) 2X6 CLG. JST.@ 16" O.C. D.F.#2(N) 4X8 HDR
(N) 2X6CLG. JST.@ 16" O.C.D.F.#213'-4"ABWP24'
BWP
1
6'-10BWP16'BWP1A42'-10"ABWP2H
T
T
4
HT
T
4
H
T
T
4
H
T
T
4
8'-8"BWP16'-1"
BWP
1
6'-8"
BWP
14
#SHEET3DATESCALEDRAWNCHECKEDBYREVISIONSADDITION FOR:
Cupertino, CA
PONCE RESIDENCE
22821 Medina Lane
(408)-406-8900 BUS.
DRAFTING AND DESIGNS BY:
A.R.E. DESIGN GROUP
SAN JOSE,CALIFORNIA
715 N. FIRST ST. ste. 34
JC9/19/18
A(E) HDR(E) HDR
(E) HDR
(E) HDR
(E) HDR
(E) HDR
(E) HDR
(E) HDR
(E) HDR(N) 4X12 HDR(E) HDR(E) HDR(E) HDR(E) HDR(E) HDR(E) HDR(E) HDR(N) 4X12 HDR
(N) 4X12 HDR
(N) 4X12 HDR (N) 4X12HDR(N) 4X8 HDR(N) 2X6 RAFTERS@ 24" O.C. D.F.#2(N) 2X8 RIDGE
(
N
)
2
X
8
F
L
A
T(N) 2X8 FLAT(N) 4X12
HDR R-1, 4X12 BEAM DF#2(N) 4X8 HDR
(E) RIDGE(N) 2X6 RAFTERS@ 24" O.C. D.F.#2INTERMEDIATE SUPPORTING MEMBERS.@ ALL EDGES & 12" O.C. @ RATED SHEATING NAILED W/ 8d @ 6" O.CROOF SHEATING TO BE 1/2" C-DX APA ROOF SHEATING4X4 POST W/ LPC4Z4X4 POST W/ LPC4Z1/150 OF ATTIC SPACE AREA OF ATTIC VENTILATION TO BE ONLY 1 VENT NEEDED FOR 80. SF.314"X16" GABLE VENTFOR JOIST SIZE SEEFRAMING PLANS(N) BEDROOM8'
7'-1"#SHEET3ADATESCALEDRAWNCHECKEDBYREVISIONSADDITION FOR:
Cupertino, CA
PONCE RESIDENCE
22821 Medina Lane
(408)-406-8900 BUS.
DRAFTING AND DESIGNS BY:
A.R.E. DESIGN GROUP
SAN JOSE,CALIFORNIA
715 N. FIRST ST. ste. 34
SECTON "A"
ROOF FRAMING PLAN
JC9/19/18