Loading...
HomeMy WebLinkAboutAH Packet 8-22-2019CITY OF CUPERTINO ADMINISTRATIVE HEARING AGENDA 10300 Torre Avenue, City Hall Conference Room C Thursday, August 22, 2019 5:00 PM ROLL CALL APPROVAL OF MINUTES 1.Subject: Draft Minutes of June 13, 2019 Recommended Action: approve or modify the Draft Minutes of June 13, 2019 Draft Minutes of June 13, 2019 ORAL COMMUNICATIONS This portion of the meeting is reserved for persons wishing to address the members on any matter not on the agenda. Speakers are limited to three (3) minutes. In most cases, State law will prohibit the members from making any decisions with respect to a matter not listed on the agenda WRITTEN COMMUNICATIONS PUBLIC MEETING 2.Subject: Architectural and Site Approval Permit to allow for an 80 square foot first-floor addition to an existing duplex. Application No(s).: ASA-2019-01; Applicant(s): Anthony Estrella (Ponce residence); Location: 22821 Medina Ln APN#342-30-011 Recommended Action: That the Hearing Officer adopt the draft resolution to: 1) Find that the proposed project is exempt from CEQA; and 2) Approve the Architectural and Site Approval Permit. Administrative Officer's decision final unless appealed Staff Report 1 - Draft Resolution for ASA-2019-01 2 - Plan Set OLD BUSINESS NEW BUSINESS STAFF AND COMMITTEE REPORTS Page 1 Administrative Hearing Agenda August 22, 2019 ADJOURNMENT In compliance with the Americans with Disabilities Act (ADA), anyone who is planning to attend the next meeting who is visually or hearing impaired or has any disability that needs special assistance should call the City Clerk's Office at 408-777-3223, 48 hours in advance of the meeting to arrange for assistance. Upon request, in advance, by a person with a disability, meeting agendas and writings distributed for the meeting that are public records will be made available in the appropriate alternative format. Also upon request, in advance, an assistive listening device can be made available for use during the meeting. Any writings or documents provided to a majority of the members after publication of the agenda will be made available for public inspection. Please contact the City Clerk’s Office in City Hall located at 10300 Torre Avenue during normal business hours. IMPORTANT NOTICE: Please be advised that pursuant to Cupertino Municipal Code 2.08.100 written communications sent to the Cupertino City Council, Commissioners or City staff concerning a matter on the agenda are included as supplemental material to the agendized item. These written communications are accessible to the public through the City’s website and kept in packet archives. You are hereby admonished not to include any personal or private information in written communications to the City that you do not wish to make public; doing so shall constitute a waiver of any privacy rights you may have on the information provided to the City . Members of the public are entitled to address the members concerning any item that is described in the notice or agenda for this meeting, before or during consideration of that item. If you wish to address the members on any other item not on the agenda, you may do so during the public comment . Page 2 Cupertino, CA 95014 (408) 777-3308 ACTION MINUTES OF THE REGULAR MEETING OF THE ADMINISTRATIVE HEARING HELD ON June 13, 2019 ROLL CALL Hearing Officer present: Ben Fu, Acting Community Development Director Staff present: Ellen Yau, Associate Planner Applicant(s) present: Steven Dauber, property owner APPROVAL OF MINUTES: 1.May 23, 2019 The minutes of May 23, 2019 were approved as written POSTPONEMENTS/REMOVAL FROM CALENDAR: None ORAL COMMUNICATIONS: None WRITTEN COMMUNICATIONS: None PUBLIC MEETING ITEMS: 2. Application No.(s): ASA-2019-03 Applicant:Steve Dauber (Dauber residence) Location: 10367 Heney Creek Pl APN# 342-48-027 Architectural and Site approval to allow a 77 square foot addition and modifications to the façade material for a single family residence located in a Planned Development Zone Administrative Hearing Officer’s decision final unless appealed. Staff member Yau addressed the Hearing Officer. The project site is located in a Planned Development that was originally approved in 1977. The property owner would like to update the entire façade of the home and enclose a balcony and a rear alcove area. This will increase the square footage by 77 square feet. The Planned Development has a zoning designation that includes Hillside Intent. This designation means that the home’s exterior should be harmonious with the surrounding landscape in color and textures. The homeowner is proposing rock veneer, HardiePlank siding and painted neutral tones over stucco. The current exterior is largely wood siding so the HardiePlank is very similar in design, but more durable. 2 Administrative Hearing June 13, 2019 The proposed exterior changes are still in keeping with the look and style of the neighborhood. The project was reviewed by other City departments, notices were sent to the neighbors and the property owner also reached out to his neighbors. Because the project site is the rear home on a tree covered flag lot, the visual impacts are minimal. The hearing officer asked for clarification that the height and footprint of the home were not changing. He also asked for the distance between the balcony (to be enclosed) and the adjacent home. Staff member Yau stated that it was about 50 feet. He asked the property owner about the outreach he conducted with his neighbors. Mr. Dauber said he emailed all of the 37 homes in the subdivision to ask how they felt about replacing some of the wood siding with stucco. He received 10 responses, 9 of these were in favor. His immediate neighbor was unable to attend tonight’s meeting, but does not have any issues with the façade changes. The Hearing Officer opened the public comment period. There were no speakers. The Hearing Officer closed the comment period. The Hearing Officer thanked the applicant for working with Staff through the process. He appreciated the work that the architect did to provide drawings that were easy to read and informational. The Hearing Officer supported the project as it maintains the original intent of the Planned Development’s style and preserved the overall feel of the neighborhood. DECISION: The application was approved by the Hearing Officer per the Draft Resolution ADJOURNMENT Respectfully submitted: _____/s/Beth Ebben Beth Ebben Deputy Board Clerk ADMINISTRATIVE HEARING STAFF REPORT Agenda Date: August 22, 2019 Subject Architectural and Site Approval Permit to consider allowing an 80 square foot first-floor addition to an existing duplex; (Application No(s).: ASA-2019-01; Applicant: Anthony Estrella; Location: 22821 Medina Lane; APN(s): 342-30-011) Recommended Action That the Hearing Officer adopt the draft resolution (Attachment 1) to: 1. Find that the proposed project is exempt from CEQA; and 2. Approve the Architectural and Site Approval Permit. Discussion Project Data: General Plan Planning Area Inspiration Heights Neighborhood General Plan Designation Low Density / Medium Density (5-10 DU/Ac.) Zoning Designation R2-4.25 Density:Existing Proposed 10 DU/acre 10 DU/acre (no change) Net Lot Area 9,064 square feet (0.21 acres) Site Development Allowed/Required Existing Proposed Lot Coverage (max 40%)3,625 sf 3,345 sf (36.9%) 3,425 sf (37.8%) 1st Floor Setbacks Front 20’21’No Change Rear (greater of 20’ or 20% of the lot depth)22’-11”20’-9”No Change Side: (greater of 6’ or 20% of lot width at front setback line) 13.8’ combined and no side less than 6’ Left: 8’-1”No Change Right: 6’-11”No Change ASA-2019-01 22821 Medina Lane August 22, 2019 Page 2 Consistency General Plan Yes Zoning Yes Environmental Assessment Categorically Exempt per Section 15301 (Class 1) of the California Environmental Quality Act (CEQA) Background: Site Description The existing duplex is located in the Inspiration Heights neighborhood near the intersection of Medina Lane and El Prado Way (Figure 1). The property abuts a planned development of attached townhomes to the north, and additional duplex properties to the east, south, and west. The existing duplex was initially constructed in 1969 with a total existing area of 3,345 square feet. The existing living space for Unit “A” is 1,421 square feet while Unit “B” is 1,123 square feet. The duplex also includes an 801 square feet three-car garage. Analysis: Conformance with General Plan and Zoning The proposed project is consistent with the General Plan Land Use Designation of Low/Medium Density (5-10 units/acre), which allows a maximum of two (2) dwelling units based on the net lot area, and the zoning designation of Residential Duplex (R-2). Architectural and Site Approval The applicant, Anthony Estrella, representing the property owner, Robert Ponce, is proposing an 80 square foot addition and minor interior remodel to Unit “B” of the existing duplex (see plan set – Attachment 2). The proposed project will increase the living area of the smaller unit from 1,123 square feet to 1,203 square feet. Total lot Figure 1. Site Aerial ASA-2019-01 22821 Medina Lane August 22, 2019 Page 3 coverage on site will increase from 36.9% to 37.8%. The R-2 Zoning Ordinance allows a maximum lot coverage of 40% for duplex units. Therefore, the proposed project does not exceed the maximum allowable lot coverage. The addition for Unit “B” is proposed within the interior courtyard area of the property, to the west of the existing unit and to the north of the existing third car garage space. Approximately 19 square feet of the third car garage space will be converted to habitable area for the addition of the proposed bedroom. This garage space is larger than the required interior dimensions for a single car garage per the Municipal Code. Therefore, after conversion, the garage would continue to conform with the requirements of the Parking Ordinance. The addition will not impact existing setbacks or result in significant visual impacts to surrounding properties. The architecture and material of the proposed addition are designed to match the existing home and be compatible with the character of the neighborhood by maintaining a similar building form and the existing total building height. Additionally, exterior finishes of the addition will be consistent with the existing building and will use stucco, similar roofing material, and windows. While no other exterior or site modifications are proposed as part of the project, the project does propose minor interior remodeling, including elimination of an interior connection from the third garage space, relocation of a coat closet and washer and dryer facilities to accommodate the addition of the new bedroom. Environmental Review This project is categorically exempt from the requirements of the California Environmental Quality Act (CEQA) per Section 15301 – Existing Facilities. Public Noticing And Community Outreach The following table is a brief summary of the noticing for this project: Notice of Public Hearing Agenda Site Signage (at least 10 days prior to hearing) 9 notices mailed to property owners adjacent to the project site (at least 10 days prior to the hearing) Posted on the City's official notice bulletin board (five days prior to hearing) Posted on the City of Cupertino’s Web site (five days prior to hearing) No comments have been received at the time of production of this staff report. Permit Streamlining Act ASA-2019-01 22821 Medina Lane August 22, 2019 Page 4 This project is subject to the Permit Streamlining Act (Government Code Section 65920 – 65964). The City has complied with the deadlines found in the Permit Streamlining Act. Project Received: March 12, 2019; Deemed Incomplete: April 1, 2019 Revisions Received: May 13, 2019; Deemed Incomplete: June 12, 2019 Revisions Received: June 24, 2019; Deemed Complete: July 11, 2019 Since this project is Categorically Exempt, the City has 60 days (until September 11, 2019) to make a decision on the project. Conclusion Staff recommends approval of the Architectural and Site Approval permit, since the plans and conditions of approval address all concerns related to the proposed project. Additionally, the findings for approval of the proposed project, consistent with Chapter 19.168 of the Cupertino Municipal Code, may be made as follows: 1. The proposal, at the proposed location, will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience; The applicant is proposing an addition of 80 square feet to an existing duplex. The proposed project complies with the allowed use of the property and does not intensify the use of the property. The addition will be located in an existinginterior courtyard area of the property. The addition is designed to be consistent with the existing duplex by maintaining the building height, building form, and exterior finishes for stucco, roofing material, and windows. No other exterior or site modifications are proposed as part of the scope of work. All of the proposed changes are minor improvements to the existing duplex and will not be detrimental to the public health, safety, general welfare or convenience. 2. The proposal is consistent with the purposes of Chapter 19.168: Architectural and Site Review of the Cupertino Municipal Code, the General Plan any specific plan, zoning ordinances, applicable planned development permit, conditional use permits, variances, subdivision maps or other entitlements to use which regulate the subject property including, but not limited to, adherence to the following specific criteria: a) Abrupt changes in building scale should be avoided. A gradual transition related to height and bulk should be achieved between new and existing buildings. The square footage added to the home is minimal. The existing wall plane height of the duplex will be maintained, and the proposed roof form will be similar to the existing roof form. Therefore, there will not result in an abrupt change in building scale. b) In order to preserve design harmony between new and existing buildings and in order to preserve and enhance property values, the materials, textures and colors ASA-2019-01 22821 Medina Lane August 22, 2019 Page 5 of new building should harmonize with adjacent development by being consistent or compatible with design and color schemes with the future character of the neighborhoods and purposes of the zone in which they are situated. The location, height and materials of walls, fencing, hedges and screen planting should harmonize with adjacent development. Unsightly storage areas, utility installations and unsightly elements of parking lots should be concealed. The planting of ground cover or various types of pavements should be used to prevent dust and erosion, and the unnecessary destruction of existing healthy trees should be avoided. Lighting for development should be adequate to meet safety requirements as specified by the engineering and building departments, and provide shielding to prevent spill-over light to adjoining property owners. The proposed architectural design, materials, and finishes, will be consistent with the existing building and harmonize with the character of the neighborhood. The project proposes no changes to the location, height, and materials of existing fencing and landscaping and does not propose any storage, utility units, and/or parking lots. Furthermore, the proposal has been designed to meet the requirements of the Residential Duplex (R-2) Ordinance. c) The number, location, color, size, height, lighting and landscaping of outdoor advertising signs and structures have been designed to minimize traffic hazard, positively affect the general appearance of the neighborhood and harmonize with adjacent development. No signage is proposed as part of this residential project. d) With respect to new projects within existing residential neighborhoods, new development should be designed to protect residents from noise, traffic, light and visually intrusive effects by use of buffering, setbacks, landscaping, walls and other appropriate design measures. The proposed project is not a new project. It is a single-story addition located within an existing interior courtyard area of an existing duplex property and will not result in any significant visual impacts to surrounding properties. The project has been designed in accordance with the development standards of the R-2 Zoning District with the intent to protect residents from unnecessary noise, traffic, light and visually intrusive effects. Additionally, the materials used and architectural articulation proposed for the addition are appropriately consistent with the existing exterior of the duplex and complements the existing neighborhood in materials and colors. The project will not be visually intrusive or cause noise, traffic, and light impacts to the adjacent properties. ASA-2019-01 22821 Medina Lane August 22, 2019 Page 6 Next Steps The permit will be effective 14 calendar days from the date of the hearing. The decision of the Administrative Hearing Officer is final, unless appealed within 14 calendar days from the date of the hearing. The applicant team may apply for building and/or other permits with the City at the end of the appeal period. This approval is valid until August 22, 2021. The applicant team may apply for a one-time one year extension before the approval expires. Prepared by: Erika Poveda, Assistant Planner Reviewed and Approved for submission by:Piu Ghosh, Principal Planner ATTACHMENTS 1. Draft Resolution for ASA-2019-01 2.Plan Set ASA-2019-01 CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 RESOLUTION NO. OF THE ADMINISTRATIVE HEARING OFFICER OF THE CITY OF CUPERTINO APPROVING AN ARCHITECTURAL AND SITE APPROVAL PERMIT TO ALLOW AN 80 SQUARE FOOT SINGLE-STORY ADDITION TO AN EXISTING DUPLEX LOCATEDAT 22821 MEDINA LANE (APN 342-30-011) SECTION I: PROJECT DESCRIPTION Application No.:ASA-2019-01 Applicant:Anthony Estrella Location:22821 Medina Lane SECTION II: FINDINGS FOR ARCHITECTURAL AND SITE APPROVAL PERMIT: WHEREAS, the City of Cupertino received an application for an Architectural and Site Approval to consider allowing an approximately 80 square foot single-story addition to an existing duplex, as described in Section I. of this Resolution; and WHEREAS, the necessary public notices have been given as required by the Procedural Ordinance of the City of Cupertino, and the Administrative Hearing Officer has held at least one public meeting in regard to the application; and WHEREAS, pursuant to the provisions of the California Environmental Quality Act of 1970 (Public Resources Code section 21000 et seq.) (“CEQA”), together with the State CEQA Guidelines (California Code of Regulations, Title 14, Section 15000 et seq.) (hereinafter, "CEQA Guidelines"), the City staff has independently studied the proposed Project and has determined that the Project is exempt from environmental review pursuant to the categorical exemption in CEQA Guidelines section 15301 for the reasons set forth in the staff report dated July 25, 2019 and incorporated herein; and WHEREAS, the applicant has met the burden of proof required to support said application; and WHEREAS, the Administrative Hearing Officer finds as follows with regard to this application: Resolution No.ASA-2019-01 July 25, 2019 Page 2 1.The proposed development, at the proposed location, will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience; The applicant is proposing an addition of 80 square feet to an existing duplex. The proposed project complies with the allowed use of the property and does not intensify the use of the property. The addition will be located in an existing interior courtyard area of the property. The addition is designed to be consistent with the existing duplex by maintaining the building height, building form, and exterior finishes for stucco, roofing material, and windows. No other exterior or site modifications are proposed as part of the scope of work. All of the proposed changes are minor improvements to the existing duplex and will not be detrimental to the public health, safety, general welfare or convenience. 2.The proposal is consistent with the purposes of Chapter 19.168, the General Plan any specific plan, zoning ordinances, applicable planned development permit, conditional use permits, variances, subdivision maps or other entitlements to use which regulate the subject property including, but not limited to, adherence to the following specific criteria: a) Abrupt changes in building scale should be avoided. A gradual transition related to height and bulk should be achieved between new and existing buildings. The square footage added to the home is minimal. The existing wall plane height of the duplex will be maintained, and the proposed roof form will be similar to the existing roof form. Therefore, there will not result in an abrupt change in building scale. b) In order to preserve design harmony between new and existing building and in order to preserve and enhance property values, the materials, textures and colors of new building should harmonize with adjacent development by being consistent or compatible with design and color schemes with the future character of the neighborhoods and purposes of the zone in which they are situated. The location, height and materials of walls, fencing, hedges and screen planting should harmonize with adjacent development. Unsightly storage areas, utility installations and unsightly elements of parking lots should be concealed. The planting of ground cover or various types of pavements should be used to prevent dust and erosion, and the unnecessary destruction of existing healthy trees should be avoided. Lighting for development should be adequate to meet safety requirements as specified by the engineering and building departments, and provide shielding to prevent spill-over light to adjoining property owners. The proposed architectural design, materials, and finishes, will be consistent with the existing building and harmonize with the character of the neighborhood. The project proposes no changes to the location, height, and materials of existing fencing and Resolution No.ASA-2019-01 July 25, 2019 Page 3 landscaping and does not propose any storage, utility units, and/or parking lots. Furthermore, the proposal has been designed to meet the requirements of the Residential Duplex (R-2) Ordinance. c) The number, location, color, size, height, lighting and landscaping of outdoor advertising signs and structures have been designed to minimize traffic hazard, positively affect the general appearance of the neighborhood and harmonize with adjacent development. No signage is proposed as part of this residential project. d) With respect to new projects within existing residential neighborhoods, new development should be designed to protect residents from noise, traffic, light and visually intrusive effects by use of buffering, setbacks, landscaping, walls and other appropriate design measures. The proposed project is not a new project. It is a single-story addition located within an existing interior courtyard area of an existing duplex property and will not result in any significant visual impacts to surrounding properties. The project has been designed in accordance with the development standards of the R-2 Zoning District with the intent to protect residents from unnecessary noise, traffic, light and visually intrusive effects. Additionally, the proposed materials and architectural articulation are proposed to be applied consistently throughout the exterior of the home and complements the existing neighborhood in materials and colors. The project will not be visually intrusive or cause noise, traffic, and light impacts to the adjacent properties. NOW, THEREFORE, BE IT RESOLVED: That after careful consideration of the maps, facts, exhibits, testimony, staff’s report and presentation,and other evidence submitted in this matter, subject to the conditions which are enumerated in this Resolution beginning on PAGE 3 thereof,: The application for an Architectural and Site Approval, Application no. ASA-2019-01 is hereby approved and that the subconclusions upon which the findings and conditions specified in this resolution are based and contained in the Public Meeting record concerning Application no. ASA-2019-01 as set forth in the Minutes of the Administrative Hearing Meeting of July 25, 2019 and are incorporated by reference as though fully set forth herein. Resolution No.ASA-2019-01 July 25, 2019 Page 4 SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPT. 1. APPROVED EXHIBITS Approval is based on the plan set drawn by A.R.E. Design Group entitled “Ponce Residence” consisting of seven (7) sheets,except as may be amended by conditions in this resolution. 2. ACCURACY OF PROJECT PLANS The applicant/property owner is responsible to verify all pertinent property data including but not limited to property boundary locations, building setbacks, property size, building square footage, any relevant easements and/or construction records. Any misrepresentation of any property data may invalidate this approval and may require additional review. 3. ANNOTATION OF THE CONDITIONS OF APPROVAL The conditions of approval set forth shall be incorporated into and annotated on the first page of the building plans. 4. CONSULTATION WITH OTHER DEPARTMENTS The applicant is responsible for consulting with other departments and/or agencies with regard to the proposed project for additional conditions and requirements. Any misrepresentation of any submitted data may invalidate an approval by the Community Development Department. 5. FENCES Any changes to the fencing shall require design review with the Community Development Department and shall comply with Cupertino Municipal Code Chapter 19.48 Fences 6. EXTERIOR BUILDING MATERIALS/TREATMENTS Final building exterior treatment plan (including but not limited to details on exterior color, material, architectural treatments, lighting fixtures, and/or embellishments) shall be reviewed and approved by the Director of Community Development prior to issuance of building permits. The final building exterior plan shall closely resemble the details shown on the original approved plans. Any exterior changes determined to be substantial by the Director of Community Development shall require a modification approval with neighborhood input. Prior to issuance of building permits, staff will review exterior material, architectural elements, and building scale and massing to ensure quality and consistency with the approved findings prescribed in Section II above. Resolution No.ASA-2019-01 July 25, 2019 Page 5 7.DEMOLITION REQUIREMENTS All demolished building and site materials shall be recycled to the maximum extent feasible subject to the Building Official. The applicant shall provide evidence that materials were recycled prior to occupancy. 8. GRADING AND CONSTRUCTION HOURS AND NOISE LIMITS The applicant shall indicate compliance with the following grading and construction hours and noise limit requirements on all demolition, construction and grading permits, and in the construction management plan(s), unless otherwise indicated. a. All grading activities shall be limited to the dry season (April 15 to October 1), unless permitted otherwise by the Director of Public works. b. Construction hours and noise limits shall be compliant with all requirements of Chapter 10.48 of the Cupertino Municipal Code. c. Grading, street construction, underground utility and demolition hours for work done more than 750 feet away from residential areas shall be limited to Monday through Friday, 7 a.m. to 8 p.m. and Saturday and Sunday, 9 a.m. to 6 p.m. Grading, street construction, demolition or underground utility work within 750 feet of residential areas shall not occur on Saturdays, Sundays, holidays, and during nighttime period as defined in Section 10.48.053(b) of the Municipal Code. d. Construction activities shall be limited to Monday through Friday, 7 a.m. to 8 p.m. and Saturday and Sunday, 9 a.m. to 6 p.m. Construction activities are not allowed on holidays as defined in Chapter 10.48 of the Municipal Code. Night time construction is allowed if compliant with nighttime standards of Section 10.48 of the Cupertino Municipal Code. e. Rules and regulations pertaining to all construction activities and limitations identified in this permit, along with the name and telephone number of an applicant appointed disturbance coordinator, shall be posted in a prominent location at the entrance to the job site. f. The applicant shall be responsible for educating all contractors and subcontractors of said construction restrictions. 9. BAAQMD BASIC CONTROL MEASURES (DUST CONTROL) Project shall comply with the Bay Area Quality Management District’s Basic Construction Mitigation Measures to reduce construction fugitive dust impacts as follows: a.All exposed surfaces (e.g., parking areas, staging areas, soil piles, graded areas, and unpaved access roads) shall be watered two times per day. Resolution No.ASA-2019-01 July 25, 2019 Page 6 b.All haul trucks transporting soil, sand, or other loose material off-site shall be covered. c.All visible mud or dirt tracked-out onto adjacent public roads shall be removed using wet power vacuum street sweepers at least once per day. The use of dry power sweeping is prohibited. d.All vehicle speeds on unpaved roads shall be limited to 15 mph. e.All roadways, driveways, and sidewalks to be paved shall be completed as soon as possible. Building pads shall be laid as soon as possible after grading unless seeding or soil binders are used. f.Idling times shall be minimized either by shutting equipment off when not in use or reducing the maximum idling time to 5 minutes (as required by the California airborne toxics control measure Title 13, Section 2485 of California Code of Regulations [CCR]). Clear signage shall be provided for construction workers at all access points. g.All construction equipment shall be maintained and properly tuned in accordance with manufacturer’s specifications. All equipment shall be checked by a certified mechanic and determined to be running in proper condition prior to operation. h.A publicly visible sign shall be posted with the telephone number and person to contact at the City of Cupertino regarding dust complaints. This person shall respond and take corrective action within 48 hours. The BAAQMD phone number shall also be visible to ensure compliance with applicable regulations. Applicant shall indicate compliance with BAAQMD’s basic control measures on all demolition, construction and grading permits and construction management plan(s). 10. CONSULTATION WITH OTHER DEPARTMENTS The applicant is responsible to consult with other departments and/or agencies with regard to the proposed project for additional conditions and requirements. Any misrepresentation of any submitted data may invalidate an approval by the Community Development Department. 11. INDEMNIFICATION Except as otherwise prohibited by law, the applicant shall indemnify and hold harmless the City, its City Council, and its officers, employees and agents (collectively, the “indemnified parties”) from and against any claim, action, or proceeding brought by a third party against one or more of the indemnified parties or one or more of the indemnified parties and the applicant to attack, set aside, or void this Resolution or any permit or approval authorized hereby for the project, including (without limitation) reimbursing the City its actual attorneys’ fees and costs incurred in defense of the litigation. The applicant shall pay such attorneys’ fees and costs within 30 days Resolution No.ASA-2019-01 July 25, 2019 Page 7 following receipt of invoices from City. Such attorneys’ fees and costs shall include amounts paid to counsel not otherwise employed as City staff and shall include City Attorney time and overhead costs and other City staff overhead costs and any costs directly related to the litigation reasonably incurred by City. 12. NOTICE OF FEES, DEDICATIONS, RESERVATIONS, OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90-day approval period in which you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90-day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. PASSED AND ADOPTED this 25th day of July, 2019 at a noticed Public Meeting of the Administrative Hearing Officer of the City of Cupertino, State of California, held by the Director of Community Development, or his or her designee, pursuant to Cupertino Municipal Code Section 19.12.120. ATTEST:APPROVED: Erika Poveda Benjamin Fu Assistant Planner Acting Director of Community Development UNIT "A"UNIT "B"ADDITION(E) GARAGE FORUNIT "A"(E) GARAGEFOR UNIT"BDRAINSLOPE 5%DRAINSLOPE 5%DRAIN SLOPE 5% DRAIN SLOPE 5%DRAINSLOPE 5%SWALEDRAIN SLOPE 5% DRAIN SLOPE 5% DRAIN SLOPE 5% DRAIN SLOPE 5%(E) 100 AMPELECT. PANELUNIT BGAS METER WATER METERUNIT BWATER METERUNIT A(E) LATERAL (E) CLEANOUTCURB 10' P.U.E.2' P.U.E.(E) DRIVEWAY (E) DRIVEWAY 24.5' REAR SETBACK LINE20' FRONT SETBACK LINE12734666SWALE(E) 6' HIGH REDWOO0D FENCE (E) 6' HIGH REDWOO0D FENCE (E) 6' HIGH REDWOO0D FENCE (E) 6' HIGHREDWOO0D FENCE(E) 6' HIGH REDWOO0D F E N C E L=69'-5"5' W.C.E.NGUMLEMONORANGEAPPLECYPRESSCREEPE-MYRTHEYUCCA1234567Contact InformationOwner Robert Ponce 408-992-1102ApplicantAnthony Estrella 408-407-8900CONTACT DATA#SHEETSPDATESCALEDRAWNCHECKEDBYREVISIONSADDITION FOR: Cupertino, CA PONCE RESIDENCE 22821 Medina Lane (408)-406-8900 BUS. DRAFTING AND DESIGNS BY: A.R.E. DESIGN GROUP SAN JOSE,CALIFORNIA 715 N. FIRST ST. ste. 34 SITE PLAN 9/18/18JC12/18/18JC 711807118081804030LS8036LS5943LS 3068 4040LS3840LS266826682668506826684268 4268 356824681668 5968 SLD. DOOR TO BE REMOVED 4040 WINDOW TO BE REMOVED 26682668 2668 2668 DR.TO BEREMOVED51'-2"(E) GARAGE(E) MASTERBDRM(E) MASTER BATH (E) BEDROOM(E) LIVING ROOM(E) KITCHEN UNIT "A"(E) GARAGEFIRE PLACE TO BE REMOVED FENCEFENCE 21'-9"7'-3"12'-4"22'-4"3'-9" 22'-8 1 16"14'-7"30'22'-9"1'-11"11'11'-9"6'-5"4'-4"10'-11"2'-6" 4'-9"51'-7"27'-1"4'-6"78'-3"AT LEAST ONE 20 AMP BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLYLAUNDRY RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHEROUTLETS. (CEC 210.11(C)(2))C)RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. (CEC210.11(C)(2))#SHEETEXDATESCALEDRAWNCHECKEDBYREVISIONSADDITION FOR: Cupertino, CA PONCE RESIDENCE 22821 Medina Lane (408)-406-8900 BUS. DRAFTING AND DESIGNS BY: A.R.E. DESIGN GROUP SAN JOSE,CALIFORNIA 715 N. FIRST ST. ste. 34 JC9/19/18 TAMPER RESISITANT RECEPTACLES PER CEC 406.11.ALL 125-VOLT, 15-AND 20-AMPERE RECEPTACLE SHALL BE LISTED OUTLETSMOTION TRIGGERED LIGHT W/ SWITCHWH71180711808180 4030LS8036LS5943LS 3068 4040LS3840LS(N) 4040 DBLPANE SLD. GLSWINDOW (EGRESS)2668(N) 3068 DR.2668506826684268 4268 35682668 (N) 6168 DBL. PANE SLD. GLS DR. (TEMP.) 3768 2668 (N) 2668 DR.R4R4R4(E) GARAGE FORUNIT B(E) MASTERBDRM(E) MASTER BATH 18 (E) BATH (E) LIVING ROOM(E) KITCHEN(N) BEDROOMUNIT "A"36" CONC.LANDING4'-1"3'-4"14'-2"(E) GARAGE FORUNIT "A"(N) 5068SOLID CORE DR.R42'-9"3'-10" (N) 2468 DR.FAU3'-3"3'-2"EGRESS22"X18"ATTICACCESS(E) BEDROOMALL FAUCETS AND WATER CLOSETSARE EXISTING.3' MINEGRESS WDEXHAUST DUCTPROVIDE 100 S.I. OFOPENING AT LAUNDRYDOOR FOR MAKEUP AIRPROVIDE 100 S.I. OFOPENING AT UTILITY DOOR FORCOMBUSTION AIR TOFURNACE AND WATER HEATERALL 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS ORDEVICES INSTALLED IN DWELLING UNIT , KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVINGROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS,HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTEDARE-FAULT CIRCUIT INTERRUPTER. (CEC 210.12)AT LEAST ONE 20 AMP BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLYLAUNDRY RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHEROUTLETS. (CEC 210.11(C)(2))(E) 100 AMP ELECT. PANELUNIT BGFIGFIALL INSTALLED LUMINARIES SHALL BE HIGH EFFICACYIN ACCORDANCE WITH TABLE 150.0-AAT LEAST ONE 20 AMP BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLYLAUNDRY RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHERALL INSTALLED LUMINARIES SHALL BE HIGH EFFICACYLAUNDRYRECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. (CEC20'A) RECESSED DOWNLIGHT LUMINARIES IN CEILING SHALL BE LISTED FOR ZERO CLEARANCE, SHALL BE CERTIFIED AS AIRTIGHT (INCLUDING EXHAUST FAN HOUSINGS), SHALL BE SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINARIES HOUSING AND CEILING , SHALL NOT CONTAIN SCREW BASE SOCKETS, AND ALL LIGHT SOURCES SHALL BE MARKED WITH "JA8-2016-E" AS SPECIFIED REFERENCE JOIST APPENDIX JA8.B) ALL FORWARD PHASE SHALL BE SWITCHED SEPARATELY FROM LIGHTING SYSTEM.C) EXHAUST FAN SHALL BE SWITCHED SEPARATELY FROM LIGHTING SYSTEMD) LUMINARIES SHALL BE SWITCHED WITH READILY ACCESSIBLE CONTROLS THAT PERMIT THE LUMINARIES TO BE MANUALLY SWITCHED ON AND OFF.E) IN BATHROOMS, GARAGE, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE LUMINARIES IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR.F) DIMMERS OR VACANCY SENSORS SHALL CONTROL ALL LUMINARIES (EXCEPTIONS: LUMINARIES IN CLOSETS LESS THAN 70sp. ft. AND IN HALLWAYS)G) RESIDENTIAL OUTDOOR LIGHTING SHALL BE CONTROLLED BY A MANUAL ON AND OFF SWITCH WITH PHOTOCELL AND MOTION SENSOR(A) AIR DUCT SHALL NOT PREVENT ACCESS TO AN AREA OF THE CRAWL SPACE(B) WHERE IT IS REQUIRED TO MOVE UNDER DUCT FOR ACCESS TO ARE OF THE CRAWL SPACE A MINIMUM VERTICAL CLEARANCE OF EIGHTEEN (18") INCHES SHALL BE PROVIDED(E) CLOTHES DRYER MOISTURE EXHAUST DUCT SHALL TERMINATE OUTSIDE THE BUILDING AND HAVE A BACKDRAFT DAMPER. EXHAUST DUCT IS LIMITED TO 14'WITH TWO ELBOWS. THIS SHALL BE REDUCED 2' FOR EVERY ELBOW IN EXCESS OF TWO.SHOW MINIMUM 4" DIAMETER, SMOOTH, METAL DUCT.(D) PROVIDE MAKEUP AIR FOR CLOTHES DRYER. WHEN A CLOSET IS DESIGNED FOR THE INSTALLED OF A CLOTHES DRYER, A MINIMUM OPENING OF 100 SQUARE INCHES SHALL BE PROVIDED IN THE DOOR. (CMC 504.4.1(1))(C) SINGLE-WALL METAL PIPE SHALL NOT BE USED AS A VENT IN DWELLING AND RESIDENTIAL OCCUPANCIES PER CMC 802.7.3.CALIFORNIA CIVIL CODE ARTICLE 1101.4 AND CAL GREEN SECTION 301.1, FORALL BUILDING ALTERATIONS OR IMPROVEMENTS TO A SINGLE FAMILYRESIDENTIAL PROPERTY, EXISTING PLUMBING FIXTURES IN THE ENTIREHOUSE THAT DO NOT MEET CURRENT FLOW RATES WILL NEED TO BEUPGRADED.A) WATER CLOSETS WITH A FLOW RATE IN EXCESS OF 1.6 gpf. WILL NEED TO BE REPLACED WITH WATER CLOSETS WITH A MAXIMUM FLOW RATE OF 1.28 gpfB) SHOWER HEADS WITH A FLOW RATE GREATER THAN 2.5 GPM. WILL NEED TO BE REPLACED WITH A MAXIMUM 2.0 gpm SHOWER HEAD.C) LAVATORY AND KITCHEN FAUCETS WITH A FLOW RATE GREATER THAN 2.2 gpm WILL NEED TO BE REPLACED WITH FAUCET WITH MAXIMUM FLOW RATE OF 1.5 gpm (OR 1.8 gpm FOR KITCHEN FAUCETS).ENERGY LIGHTING REQUIREMENTSMECHANICAL NOTESPLUMBING NOTESA) MINIMUM NET CLEAR OPENABLE DIMENSION OF 24 INCHES IN HEIGHT (R310.2.1).B) MINIMUM NET CLEAR OPENABLE DIMENSION 20 INCHES IN WIDTH (R310.2.1).C) MINIMUM NET CLEAR OPENABLE DIMENSION OF 5.7 SQUARE FEET IN AREA. GRADE FLOOR ORBELOW GRADE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SQ FT (R310.2.1).D) THE BOTTOM OF THE CLEAR OPENING SHALL NOT BE GREATER THAN 44 INCHES MEASUREFROM THE FLOOR. (R310.2.2).(G) ELEMENTS OF APPLIANCES WHICH GENERATE A GLOW, SPARK, OR FLAME (SUCH ASWATER HEATER AND FURNACE) SHALL BE LOCATED A MINIMUM OF 18 INCHESABOVE GARAGE FLOOR (CMC 305.1, CPC 507.13.).WINDOW NOTESA.ROVIDE A 120V ELECTRICAL RECEPTACLE THAT IS WITHIN 3 FEET FROM THE WATERHEATER AND ACCESSIBLE TO THE WATER HEATER WITH NO OBSTRUCTIONS.B.PROVIDE A CATEGORY III OR IV VENT, OR A TYPE B VENT WITH STRAIGHT PIPE BETWEENTHE OUTSIDE TERMINATION AND THE SPACE WHERE THE WATER HEATER IS INSTALLED.C.PROVIDE A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THEBASE OF THE INSTALLED WATER HEATER, AND ALLOWS NATURAL DRAINING WITHOUTPUMP ASSISTANCE. CLARIFY ON PLAN HOW THIS WILL BE ACCOMPLISHED.D.PROVIDE A GAS SUPPLY LINE WITH A CAPACTITY OF AT LEAST 200,000 BTU/HR.INSTALLATION REQUIREMENTS FOR NEW HOT WATER HEATER(H) SINGLE-WALL METAL PIPE SHALL NOT BE USED AS A VENT IN DWELLINGSAND RESIDENTIAL OCCUPANCIES PER CMC 802.7.3(F) DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM 26 GAGE (0.48) SHEET STEEL OR OTHER APPROVED MATERIAL OR OTHER PENETRATIONS OF GARAGE/DWELLING CEILINGS AND WALLS ARE TO BE PROTECTED (R302.11, ITEM 4).(J) AIR DUCTS INSTALLED UNDER A FLOOR IN A CRAWL SPACE SHALL BE INSTALLED INACCORDANCE WITH THE FOLLOWING: (CMC 603.2)(1) SHALL NOT PREVENT ACCESS TO AN AREA OF THE CRAWL SPACE. (2) WHERE IT IS REQUIRED TO MOVE UNDER DUCTS FOR ACCESS TO AREAS OF THECRAWL SPACE A MINIMUM VERTICAL CLEARANCE OF EIGHTEEN (18) INCHESSHALL BE PROVIDED.D) ALL DOMESTIC HOT WATER SYSTEM PIPING CONDITIONS LISTED BELOW, WHETHER BURIED OR UNBURISED, MUST BE INSULATED AND THE INSULATION THICKNESS SHALL BE SELECTED FROM THE FUILD TEMPERATURE RANGED BASED ON THE THICKNESS REQUIREMENTS IN TABLE 120.3-A (CEnC 150(J)(2)) 1) THE FIRST 5 FEET OF HOT AND COULD WATER PIPES FROM THE STORAGE TANK. 2) ALL PIPING WITH A NOMINAL DIAMETER OF 34" INCH OR LARGER. 3) ALL HOT WATER PIPES FROM THE HEATING SOURCE TO THE KITCHEN FIXTURES.#SHEET1DATESCALEDRAWNCHECKEDBYREVISIONSADDITION FOR: Cupertino, CA PONCE RESIDENCE 22821 Medina Lane (408)-406-8900 BUS. DRAFTING AND DESIGNS BY: A.R.E. DESIGN GROUP SAN JOSE,CALIFORNIA 715 N. FIRST ST. ste. 34 JC9/19/18WATER HEATER STRAP DETAILJC1/30/19 (E) STUCCO(E) STUCCO(E) STUCCO(E) STUCCO (E) STUCCO (E) STUCCO (E) ROOF LINE FOR REAR UNITS NOT FRONT UNITS(E) ROOF LINE FOR FRONT UNIT14'-5" 14'-5"(E) STUCCO(E) STUCCO(E) STUCCO(E) STUCCO(E) STUCCO(E) STUCCO14'-5" 14'-5"#SHEET2DATESCALEDRAWNCHECKEDBYREVISIONSADDITION FOR: Cupertino, CA PONCE RESIDENCE 22821 Medina Lane (408)-406-8900 BUS. DRAFTING AND DESIGNS BY: A.R.E. DESIGN GROUP SAN JOSE,CALIFORNIA 715 N. FIRST ST. ste. 34 JC9/19/18 (N) DBL PANESL GL DR.(N) STUCCOFINISH TOMATCH (E)(E) STUCCO14'-5"(E) STUCCO(E) STUCCO(N) STUCCOFINISH TOMATCH (E)(E) STUCCO(N) DBL. PANEWINDOWTEMPTEMP13'-11"#SHEET2ADATESCALEDRAWNCHECKEDBYREVISIONSADDITION FOR: Cupertino, CA PONCE RESIDENCE 22821 Medina Lane (408)-406-8900 BUS. DRAFTING AND DESIGNS BY: A.R.E. DESIGN GROUP SAN JOSE,CALIFORNIA 715 N. FIRST ST. ste. 34 JC9/19/18 EXISTING FOUNDATIONFIELD VERIFYACCESS (18" X 30" MIN) BE REMAIN) PROVIDE CRAWL SPACE AT OPENING (FOOTING TO PROVIDE (N) 4X6 HEADER CUT (E) STEM WALL TO OF UNDER FLOOR AREA(3) 5 X 14 SCREENED CRAWLSPACE VENTS TO BE 1/150(N) FTG.#5 DOWELS 16" LONGEPOXY 4" INTO (E) FTG. EMBED 12" IN EXISTING FOUNDATIONFIELD VERIFYEXISTING SLAB FOUNDATIONA4(A) FASTENERS FOR PRESERVATIVE-TREATEDWOOD SHALL BE OF HOT DIPPED ZINC-COATEDGALVANIZED STEEL, STAINLESS STEEL, SILICONBRONZE OR COPPER (R317.3.1)1) ONE-HALF-INCH DIAMETER OR GREATER STEEL BOLTS.2) PLAIN CARBON STEEL FASTENERS IN SBX/DOTAND ZINC BORATE PRESERVATIVE-TREATED WOODIN AN INTERIOR, DRY ENVIRONMENT SHALL BEPERMITTED.NAILED W/ 8d @ 6" O.C.@ ALL EDGES SUPPORTING MEMBERS.T&G APA RATED STURD-1-FLOORFLOOR SHEATING TO BE 1-1/8" & AT 12" O.C. @ ALL INTERMEDIATEFLOOR SHEATINGFOUNDATION NOTESEXCEPTIONSH T T 4 HT T 4 HTT4HTT4 (N) 2X6 FLR. JST. @ 16" OC DF#2 (N) 2X6 FLR. JST. @ 16" OC DF#2 4X4 POST W/18X18 SQR FTG.4X4 POST W/18X18 SQR FTG.(N) FTG.#5 DOWELS 16" LONGEPOXY 4" INTO (E) FTG. EMBED 12" IN GH HANGER @ GDR ENDS#5 DOWELS 16" LONGEPOXY 4" INTO (E) FTG. EMBED 12" IN (E) HDR(E) HDR (E) HDR (E) HDR (E) HDR (E) HDR (E) HDR (E) HDR (E) HDR (E) HDR(E) HDR(E) HDR(E) HDR(E) HDR(E) HDR(E) HDR(E) HDR(E) HDR(N) 4X12 HDR(N) 4X12 HDR (N) 4X8 HDR (N) 4X8 HDR (N) 4X12 HDR(N) 4X8 HDR(N) 2X6 CLG. JST.@ 16" O.C. D.F.#2(N) 4X8 HDR (N) 2X6CLG. JST.@ 16" O.C.D.F.#213'-4"ABWP24' BWP 1 6'-10BWP16'BWP1A42'-10"ABWP2H T T 4 HT T 4 H T T 4 H T T 4 8'-8"BWP16'-1" BWP 1 6'-8" BWP 14 #SHEET3DATESCALEDRAWNCHECKEDBYREVISIONSADDITION FOR: Cupertino, CA PONCE RESIDENCE 22821 Medina Lane (408)-406-8900 BUS. DRAFTING AND DESIGNS BY: A.R.E. DESIGN GROUP SAN JOSE,CALIFORNIA 715 N. FIRST ST. ste. 34 JC9/19/18 A(E) HDR(E) HDR (E) HDR (E) HDR (E) HDR (E) HDR (E) HDR (E) HDR (E) HDR(N) 4X12 HDR(E) HDR(E) HDR(E) HDR(E) HDR(E) HDR(E) HDR(E) HDR(N) 4X12 HDR (N) 4X12 HDR (N) 4X12 HDR (N) 4X12HDR(N) 4X8 HDR(N) 2X6 RAFTERS@ 24" O.C. D.F.#2(N) 2X8 RIDGE ( N ) 2 X 8 F L A T(N) 2X8 FLAT(N) 4X12 HDR R-1, 4X12 BEAM DF#2(N) 4X8 HDR (E) RIDGE(N) 2X6 RAFTERS@ 24" O.C. D.F.#2INTERMEDIATE SUPPORTING MEMBERS.@ ALL EDGES & 12" O.C. @ RATED SHEATING NAILED W/ 8d @ 6" O.CROOF SHEATING TO BE 1/2" C-DX APA ROOF SHEATING4X4 POST W/ LPC4Z4X4 POST W/ LPC4Z1/150 OF ATTIC SPACE AREA OF ATTIC VENTILATION TO BE ONLY 1 VENT NEEDED FOR 80. SF.314"X16" GABLE VENTFOR JOIST SIZE SEEFRAMING PLANS(N) BEDROOM8' 7'-1"#SHEET3ADATESCALEDRAWNCHECKEDBYREVISIONSADDITION FOR: Cupertino, CA PONCE RESIDENCE 22821 Medina Lane (408)-406-8900 BUS. DRAFTING AND DESIGNS BY: A.R.E. DESIGN GROUP SAN JOSE,CALIFORNIA 715 N. FIRST ST. ste. 34 SECTON "A" ROOF FRAMING PLAN JC9/19/18