Loading...
approved plan DIR-2018-19.pdf2 Church In Cupertino " R nAboundi Grace cianada Avn Granada Ave ,( 0 a Chrlsuan C Church a Granada Ave Q a a a a' Hermosa Awn H9nneee Ave < 70141 Orange Avenue L k s > A L-11. Aro e Q L -1v Ave L-0. Ave " VICINITY MAP GENERAL INFORMATION PROPERTY 1 ❑ 140 ORANGE AVENUE, ADDRESS: CUPERTINO, CA APN: 357-17-102 DESCRIPTION OF (1) NEW KITCHEN REMODEL 80SQ.FT. WORK: (2) MASTER BATHROOM REMODEL 120 TOTAL BUILDINGS ON SITE SQ.FT. TOTAL: (3) NEW FRONT PORCH (82 SF) DEMO AREA PORCH (4) STAIRCASE REMODEL 6❑ SQ.FT. NEW ADDITION AREA (5) REMODEL BATHROOMS (9B SF) <N> COVERED PORCH (6) FULLY SPRINKLER BUILDING 40 COUNTED TO LIVING (7) <N>+ RE ROOFED 1,294 SF <N> TOTAL BUILDING AREA ON SITE 1,759.7 SQ.FT. (8) OTHER REMODEL AREA 300 SQ.FT. (9) DEMO EXISTING FRONT FACING MAX FLOOR AREA CHIMNEY. ARCHITECT OF GEO. DESIGN RECORD: 3099 LINA LANE UNIT 4 SAN JOSE CA 95136 4086❑3❑233 GN❑VITSKIY@GMAIL.0❑M ZONING: P(RES 4.4-7.7) OCCUPANCY R3 GROUP: TYPE OF V/13C❑NSTRUCTI❑N: STORIES: TWO STORY LOT SIZE: 5,250 SQ.FT. 0 190101 W_r 0 [■l m CODE & REGULATION (E) FIRST FLOOR 1,245.7 SQ.FT. (E) SECOND FLOOR 483.5 SQ.FT. (E) GARAGE 432 SQ.FT. (E) COVERED PORCH COUNTED TO 40 SQ. FT. LIVING TOTAL BUILDINGS ON SITE TOTAL: 2,201.2 SQ.FT. DEMO AREA PORCH 40 SQ.FT. NEW ADDITION AREA <N> COVERED PORCH B2 SQ.FT. 40 COUNTED TO LIVING <N> TOTAL BUILDING AREA ON SITE 1,759.7 SQ.FT. WITH A FRONT PORCH FOOTPRINT MAX FLOOR AREA FOR A SING STORY AT 45% PER 5,250 SQ.FT MAX FLOOR AREA 2,362.5 SQ.FT. 45% COVERAGE CURRENT LOT COVERAGE WITH EAVES <E> LOT COVERAGE WITH EAVES 2,201.2 SQ.FT. 41.9% 1,785 SQ.FT. 34% 1,856.3 SQ.FT. 35.3% FLOOR CALCULATION SETBACK: 231 11 -8 REQUIRED: PROPOSED: FRONT 201 11 -❑ SIDE COMBINED 1 5 ❑° MIN. 5'-0" 1 11 REAR 2❑-❑ 1 11 MAX. HEIGHT 30-0 CODE & REGULATION ALL WORK TO COMPLY WITH THE 2016 C.B.C., C.M.C., C.P.C. & 201 6 C.E.C., CALIFORNIA TITLE 24 AMENDMENTS, AND CITY OF CUPERTINO INCLUDING THE COUNTY OF THE SANTA CLARA COUNTY 2016 CALIFORNIA BUILDING CODE 2016 CALIFORNIA RESIDENTIAL CODE 2016 CALIFORNIA MECHANICAL CODE 2016 CALIFORNIA PLUMBING CODE 2016 CALIFORNIA ELECTRICAL CODE 2016 CALIFORNIA FIRE CODE 2016 CALIFORNIA ENERGY CODE 2016 CALIFORNIA GREEN BUILDING CODE OTHER PLAN NOTES A RESIDENTIAL FIRE SPRINKLER SYSTEM IS REQUIRED, : IF AT LEAST 50% OF THE EXISTING EXTERIOR WALLS (LINEAR MEASUREMENT) AND ITS ASSOCIATED FOOTING AND ROOF FRAMING REMAIN AS EXTERIOR WALLS/FOOTINGS AND <=75% REMODEL OF CONDITIONED FLOOR AREA. SHALL BE IN ACCORDANCE WITH NEPA 13D AND STATE AND LOCAL REQUIREMENTS. ROOF AREA REMODEL 1,294 SQ.FT. ARCHITECTURAL A-1.0 COVER SHEET/ SITE PLAN A-2.0 PROPOSED PLAN / PROPOSED ELECTRICAL EXISTING ROOF ELEMENTS TO BE CHANGED A-3.0 PROPOSED AND EXISTING ELEVATIONS A-3.1 NEIGHBORING HOMES PROJECT D ATA GENERAL NOTES 1 . WORKING HOURS: No W❑PK SHALL COMMENCE ON THE JOB SITE PRIOR To 7:00 A.M. NOR CONTINUE LATER THAN 6:011P.M., MONDAY THROUGH FRIDAY, NOR SHALL ANY WORK BE PERMITTED ON SATURDY OF SUNDAY UNLESS PRIOR APPROVAL IS GRANTED BY THE BUILDING OFFICAL. 2. GENERAL CONTRACTOR SHALL VERIFY ALL UNDERGROUND UTILITY LOCATIONS PRIOR TO EXCAVATION, TRENCHING, OR GRADING OF ANY KIND. GENERAL CONTRACTOR SHALL COORDINATE WITH APPLICABLE UTILITY COMPANIES WHEN REROUTING ELECTRICAL, TELEPHONE, CABLE TV, GAS, WATER, SANITARY SEWER SERVICES, OR ANY OTHER UTILITY. G. C. SHALL MAINTAIN ALL ELECTRICAL AND COMMUNICATION SYSTEMS IN HOUSE AT ALL TIMES. 3. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL GOVERNING CODES, ORDINANCES, AND REGULATIONS. G. C. SHALL BECOME FAMILIAR WITH ALL CITY OF PALO ALTO ASPECTS OF WORKING. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION AND EXECUTION OF THE WORK SHOWN OR IMPLIED IN THE CONSTRUCTION DOCUMENTS AND IS RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, AND PROCEDURES. 4. GENERAL CONTRACTOR SHALL COORDINATE ALL FACETS OF HIS WORK AND ALL TRADES INVOLVED TO AVOID CONFLICT IN THE LOCATION, INSTALLATION, AND CONSTRUCTION OF ALL ITEMS OF WORK AS INDICATED ON THE CONSTRUCTION DOCUMENTS. IF ANY WORK IS TO BE INSTALLED BY THE OWNER DIRECTLY, ALLOWANCES FOR THE OWNERS WORK MUST BE MADE. COORDINATE WITH ARCHITECT / OWNER. 5. GENERAL CONTRACTOR SHALL LEAVE THE JOB SITE "BROOM CLEAN'l AT THE END OF EACH WORKING DAY. ALL MATERIALS SHALL BE STORED IN A NEAT AND SAFE PLACE TO AVOID ACCIDENTS, FOR CONSTRUCTION AND FOR THE OWNER. 6. IN CASE OF ANY DISCREPANCY IN THE CONTRACT DOCUMENTS, CONSULT THE ARCHITECT BEFORE PROCEEDING. 7. No DIMENSIONS SHALL BE TAKEN BY SCALING FROM THE DRAWINGS. DETAILS TAKE PRECEDENCE OVER GENERAL SECTIONS OR FLOOR PLANS. IF DIMENSIONS MUST BE CLARIFIED, CONSULT THE ARCHITECT. REFER TO THE COVER SHEET FOR DIMENSIONING STANDARDS. S. VERIFY ALL DIMENSIONS ON THE J❑B SITE PRIOR TO ORDERING OR MANUFACTURING. 9. GENERAL CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL DRAWINGS BEFORE FRAMING. COORDINATE RECESSED LIGHT FIXTURE LOCATIONS, SHAFTS, AND HVAC DUCTWORK PRIOR TO FRAMING. IT IS IMPERATIVE THAT FRAMING MEMBER L❑CATI❑NS D❑ NOT CONFLICT WITH LOCATIONS OF RECESSED LIGHT FIXTURES. IF CONFLICT EXISTS, NOTIFY ARCHITECT. 10. GENERAL CONTRACTOR SHALL INSTALL ALL APPLIANCES SPECIFIED AND ALL NEW EQUIPMENT ACCORDING TO MANUFACTURERS INSTRUCTIONS. ALL GUARANTEES, INSTRUCTION BOOKLETS, AND INFORMATION REGARDING NEW EQUIPMENT SHALL BE HANDED DIRECTLY TO THE OWNER IN ONE MANILA ENVELOPE AT THE TIME OF SUBSTANTIAL COMPLETION. CONTRACTOR SHALL VERIFY THAT EVERY PIECE [IFF EQUIPMENT AND EVERY APPLIANCE IS IN PERFECT WORKING ORDER AND THAT INFORMATION ABOUT ALL WARRANTIES AND GUARANTEES IS MADE KNOWN TO THE OWNER. 1 1 . THE INSTALLER OF EACH MAJOR UNIT OF WORK IS REQUIRED TO INSPECT THE SUBSTRATE AND CONDITIONS To RECEIVE WORK AND SHALL REPORT ALL UNSATISFACTORY CONDITIONS TO THE GENERAL CONTRACTOR AND NOT PROCEED UNTIL SATISFACTORY CONDITIONS ARE ATTAINED. 12. FOR MOUNTING HEIGHTS N❑T CLEARLY OUTLINED IN THE PLANS 13RR SCHEDULES, COORDINATE WITH THE ARCHITECT. ARCHITECT SHALL CONFIRM ALL ELECTRICAL DEVICE AND LIGHT FIXTURE LOCATIONS BEFORE CONTRACTOR PULLS WIRE. 13. PROVIDE SOLID BLOCKING AS NECESSARY FOR WALL MOUNTED SHELVES, FIXTURES, AND FITTINGS, EVEN WHEN WORK IS TO BE DONE BY OWNER DIRECTLY. REVIEW SCOPE OF WORK AND LOCATIONS FROM INTERIOR ELEVATIONS AND COORDINATE WITH OWNER/ARCHITECT. 14. ALL FASTENING DEVICES TO BE CONCEALED, UNLESS OTHERWISE SHOWN. 15. WEATHER-STRIP ALL EXTERIOR DOORS AND WINDOWS. 16. CAULK OR OTHERWISE SEAL AROUND ALL OPENINGS TO LIMIT INFILTRATION, INCLUDING BUT NOT LIMITED TO: EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, BETWEEN SOLE PLATES AND FLOORS AND BETWEEN EXTERIOR WALL PANELS. 17. GENERAL CONTRACTOR SHALL VERIFY THAT ALL WORK ON THE EXTERIOR OF THE PROJECT IS WATERTIGHT. ALL JOINTS EXPOSED TO THE ELEMENTS SHALL BE TESTED FOR WATER TIGHTNESS PRIOR TO SUBSTANTIAL COMPLETION. FIRE NOTATION: A FIRE SUPPRESSION SYSTEM TO BE REQUIRED PER THE PROVIDED CALCULATIONS FROM <E> TO NEW REMODEL / ADDITION AREA. THIS SYSTEM NEEDS TO BE INSTALLED PER CUPERTINO MUNI CODE SECTION 16.06.09❑ DEMO PLAN ❑-❑ 0 /I 8 6 EXST. WALL DEMO WALL SCALE: 3/ 6 = 1'-0'' DEM❑ FIREPLACE 1-❑ PROPOSED 0 8 6 SCALE: Y13 = 1 I_QII PLAN NEW ROOF AREA NEW ADDITION SITE NOTES: ALL DIMENSIONS AND SETBACK POINTS NEED TO BE CHECKED BEFORE THE ADDITION TAKES PLACE. PLEASE VERIFY ALL SETBACKS FROM THE BOUNDARY OF THE PROPERTY TO THE <E> HOUSE AND <N> ADDITIONS PRIER TO DIGGING NEW FOUNDATION AND POURING OF THE CONCRETE OR FORM WORK SETUP. IF THE SETBACK AT THE SITE DOES NOT MATCH UP TO THE DRAWING OR IS OVER THE ALLOWABLE SETBACK PLEASE CONTACT THE PROJECT ARCHITECT FOR FURTHER GUIDANCE ON THE PROJECT. CHANGE ❑F STYLE RESIDENCE 1 ❑ 1 40 ORANGE AVE CUPERTINO, CA 95014 GEO DESIGN 3099 LINA LANE UNIT 4 SAN JOSE CA 951 36 REVISION 09.03.18 PLANNING SUBMITTAL PROJECT NO. 1828 DATE 09.03.18 SITE PLAN A-1.0 DEMO CHIMNEY SHOOT ITS NONE STRUCTURAL AS IT HOUSES A METAL VENT DUCT. EXISTING FRONT ROOF ELEVATION SECOND FLOOR 1-2 0 2' 4' 8' SCALE: 1 /4" = 1'- 0" NEW SINGLE SLOPE T❑ BE FRAMED AS A CALIFORNIA FRAMING NO CHANGE _ TO THE ACTUAL ATTIC ONLY VENTING PENETRATI❑N FOR AIR CIRCULATI❑N \ II II II II II II II II II 1 00 BEDROOM #2 FRONT EXISTING MODIFIED AREA CROSS SECTION 0 2' 4' 8' SCALE: 1/4" - 1'-0" II II II II II II II II II 1-3 EXISTING WIND❑W TO BE REPLACED FROM A 3'-0" SILL T 1 T-6" EXISTING LEFT ROOF ELEVATION SECOND FLOOR I N STUCCO DETAIL: THREE COAT STUCCO 7/B° MIN. THICK BUILDING CODE WOOD SHEATHING (PLYWOOD, OSB) 26 GALVANIZED WEEP SCREEN AT FOUNDATION PLATE LINE AT LEAST 4° ABOVE GRADE (❑R 2° ABOVE CONCRETE OR PAVING). CRC R703.6 H 1.5 LB/1 00 SQ.FT.) IRC 201 6 1 LAYER 1 4 LB/1 00 SQ.FT. ASPHALT FELT COMPLYING WITH ASTM D 226 OR OTHER APPROVED WEATHER RESISTIVE MATERIAL UBC Weather Re WEEP SCREED IS REQUIRED BELOW THE STUCCO A MINIMUM OF 411 ABOVE Bearrler EARTH PR 2° ABOVE PAVED AREA CBC 251 2. 1 .2. WEATHER RESISTIVE BARRIERS SHALL BE INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER (R703.6.3). Conventlon� PLASTERING WITH PORTLAND CEMENT PLASTER SHALL NOT BE LESS THAN THREE Stucco COATS WHEN APPLIED OVER METAL LATH OR WIRE LATH AND SHALL BE NOT LESS THAN TWO COATS WHEN APPLIED OVER MASONRY, CONCRETE, PRESSIRE-PRESERV ABOVE TREATED WOOD OR DECAY -RESISTANT WOOD AS SPECIFIED IN SECTION R31 7.1 OR GYPSUM BACKING (R703.6.2). A MINIMUM 26 GA. GALVANIZED CORROSION -RESISTANT WEEP SCREED WITH: (R703.6.2.1 ) 1 . A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2 INCHES PROVIDED AT OR BELOW THE FOUNDATION PLATE LINE AT ALL EXTERIOR WALLS. 2. THE SCREED SHALL BE PLACED A MINIMUM OF 4 INCHES ABOVE EARTH OR 2 INCHES ABOVE PAVED AREA. RANGE/ HOOD 00 1 in O <N>SLIDER KITCHEN WIND❑W NO CHANGE TO EXISTING PLATE HEIGHT OR FRAMING ib AT THE CEILING LINE. D/W BEDROOM #2 FRONT PROPOSED MODIFIED AREA CROSS SECTION EXISTING GARAGE CROSS SECTIONPROPOSED GARAGE CROSS SECTIQN "_G�� I I >y I -4 "G r " ''// Jrr=======TIT=====__�, I G I I I I I I I I I I I 111 III III I I I I I I I I I I 111 III III I ' I I L L-- LL =_=====11L=======JJ I I I I I I I I I I I I I I I I I I I I I I L___r__ J I I I I i ___- i i I I I i i I I I I I I 1 I I 1 II I I I I I I I i2 I I I I I I I I I I 1 , I I I N I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 11 T 41__________ __________ 1 r___ i I I I LIGHTING/MECHANICAL LEGEND CEILING MOUNTED FIXTURE -cp, SWITCH p PENDANT LIGHT FIXTURE -69- 3 -WAY SWITCH CEILING MOUNTED FAN -64 SWITCH W/ DIMMER + CEILING MOUNTED FAN/LIGHT $ OUTLET H 2° ABOVE F.F.) CEILING HIGH EFFICACY EXTERIOR OUTLET W/ GROUND FAULT 141 oil CIRCUIT INTERRUPTER ® RECESSED FIXTURE (IC RATED) �& EXTERIOR OUTLET W/ GFCI RECESSED- HIGH EFFICACY 0 APPLIANCE OUTLET RECESSED- HIGH EFFICACY EXTERIOR O FLOOR ❑ UTLET WET AREA RECESSED FIXTURE mezzo 220V OUTLET • FLUORESCENT T5 N �c GAS CONNECTION • FLUORESCENT T5 - DIMMABLE --+c"[3 EXTERIOR HOSE BIB WALL -MOUNTED FIXTURE --+ GWS INTERIOR WATER SUPPLY } WALL -MOUNTED FIXTURE T W/ OCCUPANCY SENSOR* STV TV CABLE JACK EXTERIOR WALL -MOUNTED QPMONE PHONE JACK HIGH EFFICACY FIXTURE aP,4s ETHERNET PORT STRIP LIGHTING Qoe DOORBELL u AIR SUPPLY REGISTER (IST FLOOR 2FLOOR) (2ND FLOOR @ CEILING) © AIR SUPPLY REGISTER (@ BASEBOARD) ® AIR RETURN REGISTER (@ WALL) O PROGRAMMABLE THERMOSTAT (+51 -❑'l) PHOTOELECTRIC SMOKE ALARM PE W/N 20'0° OF KITCHEN OF FIRE -PLACE DUAL SENSOR SMOKE ALARM (PHOTOELECTRIC & IONIZATION) Co CARBON MONOXIDE (CO) ALARM ® EXHAUST FAN - CEILING WET AREA FLUORESCENT LIGHT ® EXHAUST DISCHARGE TO OUTSIDE LIGHT & FAN SWITCH SEPARATE * LIGHTING FIXTURES WITH OCCUPANCY SENSORS SHALL TURN OFF AUTOMATICALLY WHEN NO OCCUPANTS ARE PRESENT AND BE ONLY TURNED ON MANUALLY WITH A SWITCH. ** ALL RECEPTACLES LOCATED WITHIN THE KITCHEN AREA SHALL BE 'ITAMPER-RESISTANT RECEPTACLES' PER ARTICLE 406.1 1 OF THE C.E.C. 2016 CODE. *** ALL HOUSE LIGHTING NEED TO BE HIGH EFFICACY LIGHTING PER CEC 2016 <N>CASMENT WIND❑W 6'-0" 6'-0" 0 DINING <N>SLIDING D❑❑R PER <E_L❑CATI❑N CLOSET UP <N>FIXED WIND❑W REE II II II u <N> STAIRCASE PER EXISTING L❑CATI❑N IF 3680 COVERED ENTRY 4'-0" SHEET NOTES: E: EGRESS WINDOW - WINDOW OPENINGS IN BEDROOMS ARE TO BE A MAX. OF 44° ABOVE FINISHED FLOOR FOR EMERGENCY EGRESS. - — — - T: TEMPERED GLASS F: FIXED WINDOW 1) ALL DIMENSIONS ARE TAKEN FROM STUDS TO STUDS. 2) EXTERIOR WINDOW AND DOOR TO BE CENTERED TO THE WALL, UNLESS OTHERWISE NOTED, TYP. 3) SHOWER AND TUB/SHOWER COMBINATION IN ALL BUILDINGS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING VALVE TYPE. 4) THE MAXIMUM HOT WATER TEMP DISCHARGING FROM THE BATHTUB AND WHIRLPOOL BATHTUB FILLER SHALL BE LIMITED TO 1 20 DEG F. 5) RAISED PLATFORM SHOULD BE 1 B° ABOVE FLOOR, THAT THE WATER HEATER WILL HAVE TWO SEISMIC STRAPS AND PRESSURE RELIEF VALVE WILL BE TERMINATE AT THE EXTERIOR OF THE HOUSE. 6) 30°X24° MIN. FLOOR ACCESS DOOR. 7) PROVIDE 1 -HOUR FIRE RATED DOOR OR SELF-CLOSING, SELF -LATCHING, TIGHT FITTING, SOLID WOOD 1-3/Bl' THICK DOOR. B) TEMP. GLASS DOOR AND ENCLOSURE, TYP. MATERIALS OTHER THAN STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANT. TYP. SHOWER DOOR MIN. 2211, SHOWER AND TUB/SHOWER WALLS TO SPECIFY A SMOOTH, HARD, NONABSORBENT SURFACE (E.G., CERAMIC TILE OR FIBERGLASS) OVER A MOISTURE RESISTANT UNDERLAYMENT (E.G., CEMENT, FIBER CEMENT, OR GLASS 11 MAT GYPSUM BACKER) TO A HEIGHT OF 72 ABOVE THE DRAIN INLET. WATER- RESISTANT GYPSUM BACKING BOARD SHALL NOT BE USED OVER A VAPOR RETARDER IN SHOWER OR BATHTUB COMPARTMENTS. [R307.21 9) WALLS AND CEILING IN GARAGE SEPARATING AND SUPPORTING LIVING AREA SHALL BE COVERED WITH 5/B°TYPE °X° GYPSUM. 1 0) KITCHEN HOOD: PROVIDE A BACK -DRAFT DAMPER, HOOD SHALL BE INSTALLED DIRECTLY OVER THE COOK TOP, BE AS WIDE AS THE STOVE AND CENTERED OVER STOVE, 311° MIN. CLEARANCE FROM THE COOKING SURFACE, AND MUST BE SEPARATED BY 1/4° MIN. GAR FROM THE COMBUSTIBLES OR METAL CABINET. FURNACE AT ABOVE CEILING. KITCHEN EXHAUST FAN REQUIRED CFM AND DUCT SIZE SHOULD COMPLY WITH CA ENERGY CODE SECTION 1 5❑(❑) AND ASHRAE 62.2. 1 1) PROPOSED ELECTRICAL FUSE BOX LOCATION, CONTRACTOR TO VERIFY SPECIFIC MODEL WITH OWNER. 1 2) PROPOSED HOME NETWORK PANEL LOCATION, CONTRACTOR TO VERIFY SPECIFIC MODEL WITH OWNER. 1 3) MARBLE HEARTH, MAJESTIC GAS FIREPLACE & FLUE SYSTEM W/ REMOTE CONTROL. THERMAL VENT DAMPER, U.L. LISTING # MH601 B. 0 2' 4' 8' SCALE: 1/4" = V-0" 0" <N>FIXED WIND❑W FROSTED M ER ATH C ❑ N 2880 2880 2020 N N WARMER CURBLESS SHOWER 'ILE 121— LVATAI1:1410 MASTER BEDROOM THRESHOLD FREE SHOWER PAN AT THE MASTER BATHROOM SLOPE TO CENTER 2% <N>SLIDER WIND❑W FROSTED BATHROOM ED <N>CASEMENT co WIND❑W 0 FROSTED CLOSET D GREAT ROOM <N> GAS INSERT PER ; EXISTING GAS FIREPLACE LOCATI❑N. REMOVE FAKE CHIMNEY SHOOT VENT TO THE SIDE OF THE H❑USE GARAGE <N>CASMENT WIND❑W <N>FIXED WIND❑W co <N>CASMENT WIND❑W 111111111111111111111111111111111111� 0 2' 4' 8' REBUILT WALL REMOVED WALL CHANGE OF STYLE RESIDENCE 1 ❑ 140 ORANGE AVE CUPERTINO, CA 95014 GE❑ DESIGN 3099 LINA LANE UNIT 4 SAN JOSE CA 951 36 REVISION 09.03.18 PLANNING SUBMITTAL PROJECT NO. 1828 DATE 09.03.18 PROPOSED FLO O RPLAN A2.0 41 n lu n lu n In n In n lu n lu n In n In n II II III II III II III II III II II II N I tT u AIR SUPPLY REGISTER (IST FLOOR 2FLOOR) (2ND FLOOR @ CEILING) © AIR SUPPLY REGISTER (@ BASEBOARD) ® AIR RETURN REGISTER (@ WALL) O PROGRAMMABLE THERMOSTAT (+51 -❑'l) PHOTOELECTRIC SMOKE ALARM PE W/N 20'0° OF KITCHEN OF FIRE -PLACE DUAL SENSOR SMOKE ALARM (PHOTOELECTRIC & IONIZATION) Co CARBON MONOXIDE (CO) ALARM ® EXHAUST FAN - CEILING WET AREA FLUORESCENT LIGHT ® EXHAUST DISCHARGE TO OUTSIDE LIGHT & FAN SWITCH SEPARATE * LIGHTING FIXTURES WITH OCCUPANCY SENSORS SHALL TURN OFF AUTOMATICALLY WHEN NO OCCUPANTS ARE PRESENT AND BE ONLY TURNED ON MANUALLY WITH A SWITCH. ** ALL RECEPTACLES LOCATED WITHIN THE KITCHEN AREA SHALL BE 'ITAMPER-RESISTANT RECEPTACLES' PER ARTICLE 406.1 1 OF THE C.E.C. 2016 CODE. *** ALL HOUSE LIGHTING NEED TO BE HIGH EFFICACY LIGHTING PER CEC 2016 <N>CASMENT WIND❑W 6'-0" 6'-0" 0 DINING <N>SLIDING D❑❑R PER <E_L❑CATI❑N CLOSET UP <N>FIXED WIND❑W REE II II II u <N> STAIRCASE PER EXISTING L❑CATI❑N IF 3680 COVERED ENTRY 4'-0" SHEET NOTES: E: EGRESS WINDOW - WINDOW OPENINGS IN BEDROOMS ARE TO BE A MAX. OF 44° ABOVE FINISHED FLOOR FOR EMERGENCY EGRESS. - — — - T: TEMPERED GLASS F: FIXED WINDOW 1) ALL DIMENSIONS ARE TAKEN FROM STUDS TO STUDS. 2) EXTERIOR WINDOW AND DOOR TO BE CENTERED TO THE WALL, UNLESS OTHERWISE NOTED, TYP. 3) SHOWER AND TUB/SHOWER COMBINATION IN ALL BUILDINGS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING VALVE TYPE. 4) THE MAXIMUM HOT WATER TEMP DISCHARGING FROM THE BATHTUB AND WHIRLPOOL BATHTUB FILLER SHALL BE LIMITED TO 1 20 DEG F. 5) RAISED PLATFORM SHOULD BE 1 B° ABOVE FLOOR, THAT THE WATER HEATER WILL HAVE TWO SEISMIC STRAPS AND PRESSURE RELIEF VALVE WILL BE TERMINATE AT THE EXTERIOR OF THE HOUSE. 6) 30°X24° MIN. FLOOR ACCESS DOOR. 7) PROVIDE 1 -HOUR FIRE RATED DOOR OR SELF-CLOSING, SELF -LATCHING, TIGHT FITTING, SOLID WOOD 1-3/Bl' THICK DOOR. B) TEMP. GLASS DOOR AND ENCLOSURE, TYP. MATERIALS OTHER THAN STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANT. TYP. SHOWER DOOR MIN. 2211, SHOWER AND TUB/SHOWER WALLS TO SPECIFY A SMOOTH, HARD, NONABSORBENT SURFACE (E.G., CERAMIC TILE OR FIBERGLASS) OVER A MOISTURE RESISTANT UNDERLAYMENT (E.G., CEMENT, FIBER CEMENT, OR GLASS 11 MAT GYPSUM BACKER) TO A HEIGHT OF 72 ABOVE THE DRAIN INLET. WATER- RESISTANT GYPSUM BACKING BOARD SHALL NOT BE USED OVER A VAPOR RETARDER IN SHOWER OR BATHTUB COMPARTMENTS. [R307.21 9) WALLS AND CEILING IN GARAGE SEPARATING AND SUPPORTING LIVING AREA SHALL BE COVERED WITH 5/B°TYPE °X° GYPSUM. 1 0) KITCHEN HOOD: PROVIDE A BACK -DRAFT DAMPER, HOOD SHALL BE INSTALLED DIRECTLY OVER THE COOK TOP, BE AS WIDE AS THE STOVE AND CENTERED OVER STOVE, 311° MIN. CLEARANCE FROM THE COOKING SURFACE, AND MUST BE SEPARATED BY 1/4° MIN. GAR FROM THE COMBUSTIBLES OR METAL CABINET. FURNACE AT ABOVE CEILING. KITCHEN EXHAUST FAN REQUIRED CFM AND DUCT SIZE SHOULD COMPLY WITH CA ENERGY CODE SECTION 1 5❑(❑) AND ASHRAE 62.2. 1 1) PROPOSED ELECTRICAL FUSE BOX LOCATION, CONTRACTOR TO VERIFY SPECIFIC MODEL WITH OWNER. 1 2) PROPOSED HOME NETWORK PANEL LOCATION, CONTRACTOR TO VERIFY SPECIFIC MODEL WITH OWNER. 1 3) MARBLE HEARTH, MAJESTIC GAS FIREPLACE & FLUE SYSTEM W/ REMOTE CONTROL. THERMAL VENT DAMPER, U.L. LISTING # MH601 B. 0 2' 4' 8' SCALE: 1/4" = V-0" 0" <N>FIXED WIND❑W FROSTED M ER ATH C ❑ N 2880 2880 2020 N N WARMER CURBLESS SHOWER 'ILE 121— LVATAI1:1410 MASTER BEDROOM THRESHOLD FREE SHOWER PAN AT THE MASTER BATHROOM SLOPE TO CENTER 2% <N>SLIDER WIND❑W FROSTED BATHROOM ED <N>CASEMENT co WIND❑W 0 FROSTED CLOSET D GREAT ROOM <N> GAS INSERT PER ; EXISTING GAS FIREPLACE LOCATI❑N. REMOVE FAKE CHIMNEY SHOOT VENT TO THE SIDE OF THE H❑USE GARAGE <N>CASMENT WIND❑W <N>FIXED WIND❑W co <N>CASMENT WIND❑W 111111111111111111111111111111111111� 0 2' 4' 8' REBUILT WALL REMOVED WALL CHANGE OF STYLE RESIDENCE 1 ❑ 140 ORANGE AVE CUPERTINO, CA 95014 GE❑ DESIGN 3099 LINA LANE UNIT 4 SAN JOSE CA 951 36 REVISION 09.03.18 PLANNING SUBMITTAL PROJECT NO. 1828 DATE 09.03.18 PROPOSED FLO O RPLAN A2.0 i •1h. 11 OFF -WA \ w �r���• a "fr• lam. hie�; r lor JAMITY "70.5 1 log ? _ it INV - ow Agm Atlij J \ -- i 16 MONO—.' Mill i �r i '� � � '� 1 • � � rt ,moi~ ,r11,��`�J'_,.,Q�'_ � �1 . t a. �' 1' a�� 1• jr '� \ err 7'SV ,r � R {'."„ , t' rr � � � `� '�y' moi' ��,+`�'e 11 e` �•''TP• �, 1.� - �� ° � �},�.�+„r' ._ *• � : ' _ '� 7 �� / " 1 t. � }•.:�+ - n , , + � Asa ,vi .% r, j ', •� • yr , 1 ," 4 K.� t } . �• •' r ir`.'# 1 t e.'�" Jr Il It l*� ' `NOLi V a �: - •'��i � � • • ' +ter;: .' - IF war - age 10, ON i — --"''- •I-� 'F -ems44 - I •�'• r t+l• Mb qp if + .{ r .f - .fit •�it • �. y - Vis,.- r1' ; r'j '.'r - - - �r'3 r _ _ • r•- - _fir:• 5 : . y'; .. ,'. -1 _ _ , 's.'� r • `'•� �. M� - !� +J�lr 1. • s_I•L : R!1 .�.f R. 'i y.. LL _ Z.. - - # ` v "•t •,lig tl • ,_ • _� _ 1' 'L .. 2- �'1 piyy'� �. i+_• _ �'-fir. �. - .._ a _t' r �' - - ;:;`'s:•,r .�^ ' .�' •, _ ,,.a .'�{�' �!';� Vit• 4,!•�j• �•. � � � �' :+= a.."- � - ' Y } , - , _ r . a r \ _� -moi, - r - • r' -� - MllI CONCRETE IMIEWMMMIIII�IM N014 O O y VENEER STUCCO