Loading...
14120079 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10378 NORMANDY CT CONTRACTOR:SOLARCITY PERMIT NO: 14120079 OWNER'S NAME: BENCHORIN SHAY AND MINA 3055 CLEARVIEW WAY DATE ISSUED: 12/16/2014 OWNER'S PHONE: 4089638731 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL COMMERCIAL ❑ INSTALL 8 ROOF TOP,FLUSH MOUNTED PV PANELS(2.8 License Class 1 /-c # KW) Contractor - Date I hereby affirm at I am licensed un a provisions of Chapter 9 (commenck4g*ith Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. 1 hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$4500 1 have and will maintain Worker's Compensation Insurance,as provided for by ' Section 3700 of the Labor Code,for the performance of the work for which this APN Number:36929026.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that 1 have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 D F LLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue inst said City in consequence of the z / granting of this permit. Additi nally,th applicant understands and will co ed b Date: f) with all non-point source ions r the Cupertino Municipal Code,Section 9.18. _ ( RE-ROOFS: Signature Date I ] Y All roofs shall be inspected prior to any roofing material being installed.if a roof is installed without first obtaining an inspection,1 agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, wil I do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment"r devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area it Qualit Management District 1 performance of the work for which this permit is issued. will maintain compliance with the Cupertin Munici Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505 55 3 e 25534. Section 3700 of the Labor Code,for the performance of the work for which this "Iq permit is issued. Owner or authorized agent Date: I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,1 CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,1 must 1 hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that 1 have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION [is COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION n /O 10300 TORRE AVENUE• CUPERTINO, CA 95014-3255 l� V (408)777-3228• FAX(408)777-3333• building aacupertino.oro -\\ CtJPERTINQ PROJECT ADDRESS Jai"rh 1(R r�C� l APN# OWNER NAME �? �.(U, Y.I y I PHONE q0 {��'� _ 1� E-MAIL STREET ADDRESS I O c, y J �, C�nC J+ CITY, STATE,,"PCL") ` n L FAX �} jJ �/ Lc_Y���O� L� (J'®i CONTACT NAME Marjan Javanmard PHONE 650.477.6430 E-MAIL mjavanmard@solarcity.com STREET ADDRESS 391 Foster City Blvd CITY,STATE, ZIP Foster City, CA 94404 FAX ❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR 111 CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME SOI a rCity Corporation LICENSE NUMBER 888104 1 LICENSE TYPE C 10 BUS.LIC 428840 COMPANY NAME SolarCity Corporation E-MAIL mjavanmard@solarcity.com FAX UU STREET ADDRESS 391 Foster City Blvd CITY,STATE,ZIP Foster City, CA 94404 PHONE 650.477.6430 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF SFD Or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ NO FLOOD ZONE ❑ Yes ❑ NO I XsOLAR PANELS TO ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS. NUMBER OF PANELS/UNITS: KILOWATTS(COMMERCIAL ONLY): TOTAL VALUATION: ((3'Soo .00 DESCRIPTION OF WORK Installation O rooftop flush mounted solar panel ( c kW By my signature below,I certify to each of the following: I am th pr eowner or authorized agent to act on the pro e a . I have read this application and the information I have provided is correct. I have re the ascription of Work and verify it is accur�to comply with all applicable local ordinances and state laws relating to building construction. 1,79' i resentatives of Cupertino to enter the above id mifiwd roperty for inspection purposes. . (6 y Signature of Applicant/Agent: Date: L SUPPLEMENLAEINFORMATION REQUIRED OFFICE USE ONLY W ❑ OVER-THE-COUNTER a ❑ EXPRESS U U ❑ STANDARD U Z ❑ LARGE a ❑ MAJOR PVApp 2011.doc revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 10378 NORMANDY CT DATE: 12/16/2014 REVIEWED BY: MELISSA APN: 369 29 026 BP#: 00 'VALUATION: 1$4,500 PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RES USE: PERMIT TYPE: A WORK INSTALL 8 ROOF TOP FLUSH MOUNTED PV PANELS 2.8 k SCOPE NOTE: This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc. . Theseees are based on the preliminar information available and are only an estimate. Contact the De t or addn'l info, FEE ITEMS (Tee Resolution 11-053 Eff. 711%131 FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = # Alternative Energy System Suppl. PC Fee: ) Reg. Q OT 0.0 hrs $0.00 $236.00 IPHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:Q Reg. Q OT 1 0.0 1 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 0 Work Without Permit? ® Yes (2) No $0.00 7 E) Advanced Planning Fee: $0.00 Select a Non-Residential E) Building or Structure 0 i Strony, Motion Fee: IBSEISMICR $0.59 Select an Administrative Item BldgStds Commission Fee: IBCBSC $1.00 SUBTOTALS: $1.59 $236.00 TOTAL FEE: $237.59 Revised: 10/01/2014 ABBREVIATIONS ELECTRICAL NOTES- JURISDICTION- NOTES - - - - A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A — + AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. FLASHING WILL BE PAINTED TO MATCH EXTERIOR P"N?'�"N� IrN�z PLANS BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. Y CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3.(E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING9 DEPT. EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE D vTi. _ GALV GALVANIZED HAZARDS PER ART. 690.17. E �? GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE R MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY )l ->i:!'t. GND GROUND HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). COMMUNITY DEVELOPMENT DEPARTMENT MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN BUILDING DIVISION - CUPERTINO CUPF_RTINO (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. APPROVED v. a Duildirg Deparfrrtent NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE This set of plans and specifications MUST be kept at the OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE jcb site during construction. It is unlaxful to make any uEc 16 20% PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. changes or alterations on same, or to deviate therefrom, without approval from the Building Official. REVIENIED FOR CODE CONA.PL.IANCE PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE The Stamping of this plan and s fi r' - SHALL NOT SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. p g p Reviewed By ��"^ '7'1`W I S STAINLESS STEEL be held to permit _ an ap of the violation STC STANDARD TESTING CONDITIONS or cns of ice or State Law. TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY 2 {� V VOLT Vmp VOLTAGE AT MAX POWER VICINITY TAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT _ 3R NEMA 3R, RAINTIGHT +_ PV1 COVER SHEET � PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES PV5 THREE LINE DIAGRAM 11 Cutsheets Attached CA # 888104, 1. ALL WORK TO BE DONE TO THE 2013 :: �� • - C-10 CALIFORNIA BUILDING CODE AND THE 2013 ' CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR • AHJ: Cupertino REV BY DATE COMMENTS - REV A DW 11/10/14 inverter update • UTILITY: Pacific Gas and Electric Company - * CONFIDENTIAL - THE INFORMATION HEREIN [MODULES,' OB NUMBER: PREMISE OWNER: DESCRRiPiiON: DE GN: CONTAINED SHALL NOT BE USED FOR THE J13-9503882 00 T BENCHORIN, SHAY BENCHORIN RESIDENCE Dave WilliamsonsolarCity.BENEFIT OF ANYONE EXCEPT SOLARCITY INC., OUNTING SYSIEU: � NOR SHALL IT BE DISCLOSED IN WHOLE OR INComp Mount Type C 10378 NORMANDY CT 2.08 KW PV ARRAY �� PART TO OTHERS OUTSIDE THE RECIPIENT'S CUPERTINO CA 95014 3055 CIearview Way ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (8) REC # REC260PEZ PAGE NAME SHEET: REV. DATE Son Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION of SOLARCITY INC. SOLAREDGE SE3000A—US—ZB—U (408) 963-8731 COVER SHEET PV 1 G 12/10/2014 (888)-SOL-CITY(765-2489)www.solarcity.com PITCH: 18 ARRAY PITCH: 18 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 1 Story c� v � Inv O o Y UllO J C D U _? CUPERTINO +� E3ulldirg Department o (E) DRIVEWA 00 i) SUR COLE CON'•PLIANC:E 0 K FSB MP1 Rev:evej By LEGEND (nI M WI O (E) UTILITY METER & WARNING LABEL RINVERTER W/ INTEGRATED DC DISCO & WARNING LABELS A Dc DC DISCONNECT & WARNING LABELS FAC I AC DISCONNECT & WARNING LABELS O DC JUNCTION/COMBINER BOX & LABELS DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L=�J r TOTAL ARRAY AREA (SF): 145 SITE PLAN N TOTAL ROOF AREA (SF): 2265 Scale: 1/8" = 1' W E a TOTAL ARRAY AREA IS a 6% 0 1' 8' 16' 1. PERCENT OF TOTAL ROOF AREA CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE J B-9503882 00 \���• BENCHORIN, SHAY BENCHORIN RESIDENCE Dave Williamson �Olar.�l}" BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �•A� 1.ri NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 10378 NORMANDY CT 2.08 KW PV ARRAY PART OTHERS OUTSIDE THE RECIPIENT'S MODULES: CUPERTINO, CA 95014 3055 Clearvew Way ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (8) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE Son T:(650)638 ate CA 94402 )638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE3000A—US—ZB—U (408) 963-8731 SITE PLAN PV 2 a 12/10/2014 (888)-SOL-CITY(765-2489) www.saurcity.com S1 4" —4 11'-5" (E) LBW SIDE VIEW OF MP1 NTS A MPI X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 2411 PORTRAIT 48" 20" RAFTER 2X8 @ 24° OC ROOF AZI 180 PITCH 18 STORIES: 1 ARRAY AZI 180 PITCH 18 Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH ZEP COMP MOUNT C - POLYURETHANE SEALANT. I CUPERI 3 ZEP FLASHING C (3) (3) INSERT FLASHING. Bulldirg Dcoarunani (E) COMP. SHINGLELurk (1) (4) PLACE MOUNT. " (E) ROOF DECKING (2) REVIEOjEID r-OR CODE C0tfPLIANCE LL 5/16" DIA STAINLESS (5) (5) INSSEALINGGWAOSHER.LT ITH � Reviewed By STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER G(6) BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER STAN DOFF CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: J13-9503882 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE BENCHORIN, SHAY BENCHORIN RESIDENCE Dave Williamson SolarCit BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: c NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount T C 10378 NORMANDY CT 2.08 KW PV ARRAY y �, c PART TO OTHERS OUTSIDE THE RECIPIENTS MODULE P e C U P E R TI N O C A 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH r THE SALE AND USE OF THE RESPECTIVE (8) REC # REC260PEZ 3055 gearvier Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: :(650)638 PAGE NAME SHEET: REV. DATE: Son TM0e CA 94402 638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE3000A-US-ZB-U (408) 963-8731 STRUCTURAL VIEWS PV 3 a 12/10/2014 (888)-SOL-CITY(765-2489)www.solorcity.com UPLIFT CALCULATIONS 10.06.2014 ��,,;So�arCity SleekMountTM PV System Version#39.1 Structural Desian Software Project Information&Table Of Contents Risk Category: H PV System Type SolarCity SleeWount— Comp Roof Comp Roof Layers of Comp Roofing 1 Roof Slope 180 Rafter Spacing 24"O.C. PV System Module Orientation Landscape and Portrait PV Module Area 142 sf PV Module Width 39" PV Module Length 66" Standoff Attachment Hardware Comp Mount Type C i I Reduced Ground/Roof Live/Snow Loads Ground Snow Loadpg 0.0 psf ASCE Table 7-1 Surrounding Roof Snow 0.0 psf ASCE Eq:7.4-1 Roof Snow Over PV Modules 0.0 ASCE Eq:7.4-1 Wind Design Criteria Wind Design Code ASCE 7-10 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 110 mph Fig.26.5-1A Exposure Category C Section 26.7 Roof Style Gable Roof Fig.30.4-2A/B/C-SA/B Mean Roof Height h 15 ft Section 26.2 Effective Wind Area 1 Module A 17.8 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.85 Table 30.3-1 Topographic Factor Kzt 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importpnce Factor I NA Velodty Pressure qh qh=0.00256 224(ice)(Kd)N^2) Equation 30.3-1 Ext.Pressure Coefficient(Up) GCp(Up) -0.88 Fig.30.4-ZA/B/C-5A/8 Ext.Pressure Coefficient Down G Down 0.45 LQ.30.4-2A/8/C-5A/8 Design Wind Pressure P p=gh GC Equation 30.4-1 Wind Pressure Up p(up) -19.6 psf Wind Pressure Down down 16.0 psf Allowable Standoff Spacings X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Confi oration Landscaa Not-Sta gered '.�ERTINO Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W-PV 3 psf �?!►��F1TIl�Dt Net Wind Uplift at Standoff T-actual -196 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 391% Max Allowable Standoff Spacing Portrait 48" 66" Max Allowable Cantilever Portrait 20" �NA %C)Pf F'f_!Ai�IG Standoff Configuration Portrait Not-Staggered f Max Standoff Tributary Area Trib 22 sfi I7•�7 PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -219 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff DemandlCapacity I DCR 1 43.8% J B-9 5 0 3 8 8 2 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL A THE INFORMATION HEREIN JOB NUMBER: Dave Williamson \���SO�arC�t • CONTAINED SHALL NOT BE USED FOR THE BENCHORIN, SHAY BENCHORIN RESIDENCE y BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 10378 NORMANDY CT 2.08 KW PV ARRAY PART IZ OTHERS OUTSIDE THE RECIPIENT'S MODULES CUPERTINO CA 95014 3055 Cleorview way ORGANIZATION, EXCEPT IN CONNECTION WITH � THE SALE AND USE OF THE RESPECTIVE (8) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN ateo, CA 94402 INVERTER: PAGE NAME SHEET: REV: DATE: SonT:(650) 638M028 F:(650) 638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE3000A—US—ZB—U (408) 963-8731 UPLIFT CALCULATIONS PV 4 G 12/10/2014 (888)-SOL-CITY(765-2489) www.solarcityxam GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) GROUND ROD Panel Number:Square D Inv 1: DC Ungrounded ## ## CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:1006680342 INV 1 —(1)Inverter; 3000WE 240V 9.5�B w/Unlfed Disco and ZB, AFCI —(8)RPV f�odule262260W, 234.3W PTC, MC4, 40mm, Black Frame, ZEP Enabled C-10 Underground Service Entrance INV 2 Voc: 37,8 Vpmox: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 200A MAIN SERVICE PANEL E; 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 20OA/2P 3 SOLAREDGE SE3000A—US—ZB—U (E) LOADS L1 F2--Vl SolarCity L2 20A/2P EGG OC+ 2 A A �———————--———— — GEC ---T N DG L: 1X 6 I GND EGC —————- -- ---------------------------- ---,---d+IGLC ---------- I I I N I I EGC/GEC — Z Z CSI GEC TO 120/240V SINGLE PHASE UTILITY SERVICE I GUIPERTINO Uuilctirg Deprrtr rent CEC 16 201 REVIEVNJEL) rOR CODE Ct MIPLlNCE , Reviewed By. ��•� f7/A;1= I Voc* = MAX VOC AT MIN TEMP POI (I)SQUARE D !!H MT1515 O PV ACKFEED BREAKER /f, A (1)SdorCityy 4 STRING JUNCTION BOX D� Breaker, 15A 1P-20A 2P-15A/IP, 2 Spaces, Quad Tandem /� 2x2 STR GS, UNFUSED, GROUNDED — (I)SQUARE D H 12020 30 PV (8)SOLAREDGE IP300-2NA4AZS ;pp PowerBox Optimizer, 30OW, H4, DC to DC, ZEP Breaker, 20A 1P-30Af2P-20A/1P, 2 Spaces, Quad Tandem (1)AWG #10, THWN-2, Black (1)AWG /10, THWN-2, Block Voc* =500 VDC Isc =15 ADC (2)AWG #10, PV WARE, Black Voc* =500 VDC Isc =15 ADC O (1)AWG /10, THWN-2, Red O (I)AWG #10, THWN-2, Red Vmp =350 VDC Imp=5.87 ADC O (1)AWG #10, Solid Bare Copper EGC Vmp =350 VDC Imp=5.87 ADC LLL���LLL (1)AWG /10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=12.5 AAC (1)AWG /10, THW N-2, Green EGC. . . .7(1 Conduit Kit; 3/4' EMT —(11)AWG /8,.TIiWN-2,.Green EGC/GEC_-(1)Conduit_Kit; 3/4'_FAIT_ . . . . . . . CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER JB-9503882 00 PREMISE OWNER: DESCRIPTION: DESIGN: BENCHORIN, SHAY BENCHORIN RESIDENCE Dave Williamson 'SolarCit CONTAINED SHALL NOT BE USED FOR THE �\1�• ' BENEFIT OF ANYONE EXCEPT IN W-IO E INC., MOUNTING SYSTEM: 0378 NORMANDY CT 2.08 KW PV ARRAY �►�� y NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: C U P E R TI N 0, CA 95014 THE SALE AND USE OF THE RESPECTIVE (8) REC # REC260PEZ 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER: T:(650) 638-1028 F:(650)638-1029 SOLAREDGE # SE3000A—US—ZB—U (408) 963-8731 THREE LINE DIAGRAM PV 5 0 12/10/2014 (888)-SOL-CITY(765-2489)www.solarcity.com WARNING:PHOTOVOLTAIC POWER SOURCE PV SYSTEM WARNING Label Location: Label Location: Labell-ocation: Per Code: DISCONNECT FOR ••- CRC R331.2UTILITY OPERATION ELECTRIC SHOCK HAZARD CEC . THE DC CONDUCTORS OF THIS Label Location: PHOTOVOLTAIC SYSTEM ARE • BE USED WHEN PHOTOVOLTAIC DC UNGROUNDED ANDINVERTERIS DISCONNECTPer Code: MAY BE ENERGIZED UNGROUNDED CEC .•0 .14.C.2 Label Location: WARNING Code:Per Label ELECTRIC SHOCK HAZARD Location- DO NOT TOUCH TERMINALS CEC 6. MAXIMUM POWER-_ TERMINALS Mw LINE AND POINT CURRENT(Imp) A •- - LOAD SIDES MAY BE ENERGIZED MAXIMUM POWER-_VCEC •. IN THE OPEN POSITION POINT VOLTAGE(Vmp) MAXIMUM SYSTEM V VOLTAGE(Voc) SHORT-CIRCUIT_ CURRENT(Isc) A Label • • WARNING (POI)Code:Per CEC 705.12.D.7 INVERTER OUTPUT CONNECTION Label Location: DO NOT RELOCATE WARNING ' Code:• THIS OVERCURRENT Per DEVICE ELECTRICAL SHOCK HAZARD 690.17 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITIONLabel L• • DC VOLTAGE IS PHOTOVOLTAIC POINT OF '• ALWAYS PRESENT WHEN INTERCONNECTIONPer Code: SOLAR MODULES ARE WARNING: ELECTRIC SHOCK 690.54; 690.17 PP EXPOSED TO SUNLIGHT HAZARD. DO NOT TOUCH TERMINALS.TERMINALS ON Depaqjieni BOTH THE LINE AND LOAD SIDE OEC I E 2014 MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE Label Location: DE-ENERGIZE BOTH SOURCE AND MAIN BREAKERINV) . WARNING Per ,,_ PV POWER SOURCE ELECTRIC SHOCK HAZARD MAXIMUMAC _ A • IF A GROUND FAULT IS INDICATED 690.5(C) OPERATING CURRENT NORMALLY GROUNDED MAXIMUMAC _V CONDUCTORS MAY BE OPERATING VOLTAGE UNGROUNDED AND ENERGIZED Label • • Label .Location: CAUTION 'I) Per Code: PHTOVOLTAIC AC _ PHOTOVOLTAIC SYSTEM DISCONNECTCode: CIRCUIT ISBACKFED 690.64.B.4Conduit CEC 6.0 - :• Interior(D): Distribution Panel (DC): DC Disconnect • Label ..- Inverter _ qP• CAUTION P• •-• Center Per OPERATING CURRENTCode: DUAL POWER SOURCE Per Code MAXIMUMACCEC 690.54 SECOND SOURCE IS • Interconnection OPERATING VOLTAGE V PHOTOVOLTAIC SYSTEM oint o • • 3055 Cleaview Way • San _ ., •� � � • ' 0638 029 • r 1111"i WIWI! / (888)-SOL-CM(765-2489)www.solarcity.com SolarCity SleekMountT"" - CompSolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution • Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep Compatible T1^modules aesthetics while minimizing roof disruption and O Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and Interlock and grounding devices in system UL � � Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition listed to UL 2703 of array trim and a lower profile all contribute • Interlock and Ground Zep ETL listed to UL 1703 - • Seal pilot hole with roofing sealant to a more visually appealing system.SleekMount as"Grounding and Bonding System" ` O` • Insert Comp Mount flashing under upper utilizes Zep Compatible TM modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device • Place Comp Mount centered Zep Solar standoffs, effectively eliminating the need for rail and reducing the number of • Painted galvanized waterproof flashing upon flashing standoffs required. In addition; composition .Anodized components for corrosion resistance • Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions • Secure Leveling Foot to the Comp Mount using machine Screw • Place module A Components A 5/16" Machine Screw B Leveling Foot CUPERTINO ,,GLag Screw I� i x f F3Uil�irr �� a R) Comp Mount r 1 E Comp Mount Flashing 1� Y �; UtC 1 6 2014 C REVIEWED FOR COCE COMPLIANCE 0o Reviewed By. D �- 0 E G�0%"MPPAPI, V� LISTED SoiarCity. JanuarY2013Soia�ity® January 2013 E 5 a W# • 9 so I a r - . � so I a r " e • z SolarEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer Module Add-On For North America 6300 6350 9400 (for iso-cell PV (for 72-cell Pv (for 96-cell PV modules) modules) modules) P300 / P350 / P400 • INPUT _ Rated Input DC Powerl'I _ 300 350 400 W Absolute Maximum input Voltage oc at low ..m....t,.re.. -.. ........ "" 60......... .........80..."" Vdt ...........................putV....g..(Voc.tlo est to;pera_u..l. MPPT Operating Range...................... 8-.' .....................8..-60.......... ......... ..........................�............. ...................... • Maximum Short Circuit Current(Ist) ..I......___"...........................10_,. .,,.,_.,Adc.. Maximum DC Input Current 12.5 Adc .............................................................................................................................................................................. Maximum Eff-ic'Tncy 99.5 9G Weighted Efficiency 98.8 % 0vervokage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) _ Maximum Output Current _....................15..................... Adt ` .... .........vut voltage......... ................................................................ ................................ Maximum Ou[ 60 Vdc • _OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE Q5�" • EMC FCC Part15 Class 8,IEC61000-6-2,IEC61000 6 3 WaRatttY .Safety.................................................................. ...................IEC62309-1(class Il safety),UL1741.................. .............................._.................................................................09-.. las.11 s... .............................._......... RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc .. .. ... . . ...... ... w' Dimensions(W x L x H) 141 x 212 x 40.5/555 x 834 x 1.59 �7�,.0 R �NO W.... .irKJudingtables) ........ ......... ...... ......... ... .. 950/2.1 .............. r,,? Ib,.. U�II�(� D� arrfi'lent Input Connector MC4/Amphenol/.Tyco Output Wire Type/Connector Double Insulated;Am henol .,. _......._................_..................................................... ............,.t.,...a` �.i... Output Wire Length 0.95/3.0 1.2/3.9 ft _ ......................... _._ ....._.._........... ... _. ...... ................... .._........_ ......_.............. Citi, 1 20f4 Operating Temperature Range -40-+85/-00-+185 _ 'C/'F ._.... 8 ......... ................. .. .. .. .. .............. Protection Rain IP65/NEMA4 .� .......__.._............................_..._.............................................,..................._................................:..-........ Relative Humidity, 0-1D0 % F.kA.,El_: SUR GORE COMPLIANCE - - - -- -- - --- -- PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE,±r:\'if.`IfYE'.�.1 B / z✓�' �'�T INVERTER 208V 480V PV power optimization at the module-level Minimum S.tring Length(Power Optimizers) 8 10 18 ................................ Up to 25°o more energy ..Maximum String Length(Power Optimizers) 25 25 50 .......................................................................................................................................................................... Maximum Powerper String 5250 6000 12750 W Superior efficiency(99.5%) _Parallel.Strings of Different Lengths or.Orientations . ........... . — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading "'.... . ........................ — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us so I a r " - Single Phase Inverters for North America =se , •solarSE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE760OA-US/SE1000OA-US/SE1140OA-US SE3000A-US ISE380OA-US I SE5000A-US SE6000A-US I SE7600A-US SE10000A-US SEI140OA-U5 OUTPUT So I a rE d g e Single Phase Inverters . Nominal AC Power Output 3000— 3800 - 5000 -! 6000— 7600 1980 @ 208V 0000 @240V 11400 I VA . . . ... .... 5400 @ 208V 10800 @ 208V For North America Max.AC Power Output 3300 4150 6000 8350 12000 VA 5450 @240V 10950 @240V AC Output Voltage Min.-Nom.-Max.* J J SE3000A-US/SE380OA-US/SE5000A-US/ SE6000A-US/ COutp8-229Vac J J J J ,..,..,2 .......................... ....... ........... . SE760OA-US/ SE10000A-US/ SE1140OA-US ACOutputVol tageMln:Nom._Max." S 211-240-264 Vac AC Frequen Mtn:Nom:Max.' S9.3-60-60.5(with HI country Settin 57 60-60.5) Hz ,,.,�............... Il 24 @ 208V 48 @ 208V Max.Continuous Output Curren[ 12.5 16 25 32 47.5 A ............... 21 @ 240V ................ ................ ...42 @ 240V... .............,.... GFDI1 A y.' Utility Monitoring,Islanding d Protection,Country Configurable Yes ,,verte, Thresholds m 12�etC,• INPUT ' �ieaa Recommended Max.DC Power*' 3750 4750 6250 7500 9500 12400 14250 W (STC).................. ........... .........I........ .................. .........,. •'atlea��' Transformer less,Ungrounded Yes Max.Input Voltage 500 Vdc Nom.DC In put Voltage 325 @ 208V/350 @ 240V Vdc A 16.S @ 208V I 33 @ 208V Max.In ut Current"' 9.5 13 18 23 34.5 Adc P 15.5@ 240V .30-... @ 240V Max.Input Short Circuit Current 30 45 Adc ....................................... ................._..I........... ............. Reverse-Polarity Protection Yes .......................................... ....................................................................ri.................................................... ......... . Ground-Fault Isolation Detection 600kn Sensitivi .Maximuminverter,Efficienty .....97.7.... ...98:2.-. .....98:3..... ,...98.3_ •.....98.•••• „98..,,, ......98,.... ..%..... ...,........ ... - .. .. .. .. .. ,.. .. - CEC Weighted EfficiencyEfficiency97.5 @ 208V 97 @ 208V 97.5 98 97.5 97.5 97.5 % 98 @ 240V 97-5 @ 240V Nighttime Power Consumption <2.5 <4 W 1 ADDITIONAL FEATURES ;,--- ` Supported Communication rfa Inteces RS485,RS232,Ethernet,ZigBee(optional) l _ PERT!N Revenue Grade Data,ANSI C171 Optional `"ljliGlrp pCDwr(m erlt STANDARD COMPLIANCE wl a' + rt Safe UL1741,UL3699...UL1998,CSA22..........,a- ^� EmI(a Grid.Connection Standards IEEE1547 . 1 .. .. .... .. ... .... .. ... ..... ................... .......... P.-...-. ......_.. :4..:-.::.�_..a..... ....... .......issions..... ........ FCC art15 class B INSTALLATION SPECIFICATIONS _ �+ AC output conduit size/AWG range 3/4"minimum/24-6 AWG 3/4'm hituiM Yg A COPD!R�I NC E J i , DC input conduit size/N of strings/ / AWG ran a 3/4"minimum/1-2 strings/24-6 AWG 3/4'minimum/1-2 5tr'f�5/ ¢6 A18f� Q �? g , ti`.c N . 4� ......w1� .......................................... ................................ .................................. ................................................... Dimensions with AC/DC Safety 30.5 x 12.5 x 7/ 30.5 x 12.5 x 7.5/ 305 x 125 x 105/775 x 315 x 260 in/ a _ Switch(HxWxD) 775 x 315 x 172 775 x 315 x 191 . . . mm _ Weight with AC/DC Safety Switch•• . •.••• 511,2J.2.3.2 ....... . 5.4,.7./.24.7 88.4/40.1 Ib/.k Cooling Natural Convection Fans(user replaceable) .................................. ......................................... ....................... ....................•................................. ........... The best choice for SolarEd a enabled systems Noise <25 <50 1. dBA Y Min.-Max.Operating Temperature + + CAN version**** +60 'F ' -13 to 140 -25 to 60 emon'* *-AElto C Ran e / ( ) / Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance ...�. . ..................................................................................................................... ........... Protection Rating ......................NEMA 3R ............................................. Superior efficiency(98% ............................ .................- ........... 'For other reg nal settings please contact Sdarfdge support. Small,lightweight and easy to install on provided bracket •Um ted to 12S%for locations where the yearly average high temperatumisabove 77'F/25'Land to 135%for locationswhere it is below 777/25•G For detailed information,refer to htto://www.solaredee.us/file•Jodfsfnyener do oversizina euide.od( Built-in module-level monitoring .••Ahigher—tsource may bented;the inerterwilllimititsinput—renttollhe aW•aat«a. "CAN P/Ns are eligible for the Ontario FIT and microFlT(microl lText.SESS<DOA-USCANI. Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter,DC/AC conversion only Pre-assembled AC/DC Safety Switch for faster installation Optional—revenue grade data,ANSI C12.1 r �g lsvEo USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us OPINIZED BY SOLAREDGE are,trademarks or rep)stered trademarks of , _ Technologies. Date: 03/2.014. V.02.SAW to change without,ollce. REC PEAK ENERGY Z-LINK 6S w EFFICIENCY HIGH PERFORMANCE SOLAR PANELS YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY REC PEAK +4T �'-9r OVTY*F U5 IMPORT DUTY FREE A' RFE ENERGY TEMPERATURE RATINGS Nominal Operating Cell Temperature(NOCT) 45.7°C(z2°C) ' 1 Temperature Coefficient ofPMon -0.40%/°C Temperature coefficient of V., -0.27%/'C REC Peak Energy Z-Link Series panelAll measurements�n inches s are ' - Temperature Coefficient of is, 0.024%/ec the perfect choice for bui,ding solar ELECTRICAL r systems that combine long lasting Nominal Power-P,..,,,(Wp) 255 260 265 Cell Type: 60 REC PEmulti-crystalline product quality with reliable power output. Watt class Sorting-(Wp) m5 m5 15 3 strings of 20 cells with bypass diodes r RECcombineshighqualitydesignand Nominal Power Voltage-V,,,(V) 30.5 30.7 30.9 Glass: 1/8"mm solar glass with anti-reflection surface treatment manufacturngstandards toproduce high- Nominal Powercurrent-Iµ9(A) 8.42 8.50 8.58 Back Sheet Double layer highly resistant polyester Open Circuit Voltage-Vor(V) 37.6 37.8 38.1 Frame: Anodized aluminum(black) performance solar panels with ShortCircuit Current-I,,(A) 8.95 9.01 9.08 ZepGroove compatible uncomprom sing quality. Panel Efficiency(%) 15.5 15.8 16.1 Junction Box: IP67rated 4 mm=solar cable,47"«47" The electrical characteristics are within 10%of the indicated values of 1-Vr,and P.,at standard Test conditions(STC). Values at siendei d test conditions STC(airmass AM 15,in adlance 1000 W/m',ceo temperature z5°C). Connectors: Multi-Contact MC4(4 mm2) At low irradiance of 200 W/m'(AM 1.5 and cell temperature 25°C)at least 97%of the STC panel efficiency will be achieved. Origin: Made In Singapore ELECTRICAL DATA @ r INO F Nominal Power-P�o(Wp) 193 197 202 OperationalTemp¢ratufe i -40.t18S°F(; ACpMPp(�� Nominal PowerVoltage-VMi„(V) 28.5 29.0 29.4 Maximum syspelthV0ltage: 1 rtlt�@fit Nominal Power Current-1.(A) 6.77 6.81 6.90 Design Load'; ` 501bs/ft2(2400Pa)longside MORE POWER COMPATIBLE WITH PERFT' ZEPGROOVEFRAME Open Circuit Voltage-Vnr(V) 35.3 35.7 36.030lbs/ft'(1436Palshortside Short Circuit Current-Is,(A) 7.21 7.24 7.30 Max Series Fuse Rating_ 15A Nominal operating cell temperature NOCT(800 W/m',AM 1.5,windspeed I m/s,ambient temperature 20•C). Max Reverse,,,C'Tilq`L•`�: is (v (f 1�• I/A A ITC CERTIFICATION MECHANICALDATA •1^TvrT 10 year product warranty. Dimensions: 65112 x 39 x 1'/z in(1665 x 991 x 40 mm) c �L us 25 yeartinearpoweroutputwarranty Area: 173/Qft2(1.65 m2) USIMPORT INSYTOTALL LISTED (max degressioninperformance of07%p.a.). DUTY FREE INSTALL UL 17133.Fire rating.Class C Weight: 431bs(19.5 kg) Note! All given specifications are subject tochange without notice at anytime. REC is a leading global provider of solar energy solutions. With more than 15 years of experience,we offer sustainable,high performing ^ products,services and investments for the solar industry. Together with our partners,we create value by providing solutions that better I meet the world's growing energy needs.REC is headquartered in Norway and listed on the Oslo Stock Exchange(ticker:RECSOL) Our 1,600 employees worldwide generated revenues of USD 647 million in 2013. www.recgroup.com