Loading...
HomeMy WebLinkAboutAH Packet 2-08-2018CITY OF CUPERTINO AGENDA C U P E RT I N O ADMINISTRATIVE HEARING 10300 Torre Avenue, City Hall Conference Room C Thursday, February 8, 2018 5:00 PM ROLL CALL APPROVAL OF MINUTES 1. Subject: Draft Minutes of January 11, 2018 Recommended Action: Approve or modify the draft Minutes of January 11, 2018 Draft Minutes of January 11, 2018 POSTPONEMENTS ORAL COMMUNICATIONS This portion of the meeting is reserved for persons wishing to address the members on any matter not on the agenda. Speakers are limited to three (3) minutes. In most cases, State law will prohibit the members from making any decisions with respect to a matter not listed on the agenda WRITTEN COMMUNICATIONS PUBLIC MEETINGS 2. Subject: Architectural and Site approval to allow exterior building and site modifications to an existing Jack in the Box restaurant. Application No(s): ASA -2017-07; Applicant(s): Greg Borchardt (Albert Tung); Location: 1451 S De Anza Boulevard APN# 366-19-044, 366-19-045 Recommended Action: That the Administrative Hearing Officer adopt the Draft Resolution to: 1 - Find that the proposed actions are exempt from CEQA; and 2 - Approve the Architectural and Site Permit Postponed from the October 26, 2017 meeting Administrative Hearing Officer's decision final unless appealed Page 1 Administrative Hearing AGENDA February 8, 2018 Staff Report 1 - Draft Resolution 2 - Plan Set OLD BUSINESS NEW BUSINESS ADJOURNMENT In compliance with the Americans with Disabilities Act (ADA), anyone who is planning to attend the next meeting who is visually or hearing impaired or has any disability that needs special assistance should call the City Clerk's Office at 408-777-3223, 48 hours in advance of the meeting to arrange for assistance. Upon request, in advance, by a person with a disability, meeting agendas and writings distributed for the meeting that are public records will be made available in the appropriate alternative format. Also upon request, in advance, an assistive listening device can be made available for use during the meeting. Any writings or documents provided to a majority of the members after publication of the agenda will be made available for public inspection. Please contact the City Clerk's Office in City Hall located at 10300 Torre Avenue during normal business hours. IMPORTANT NOTICE: Please be advised that pursuant to Cupertino Municipal Code 2.08. 100 written communications sent to the Cupertino City Council, Commissioners or City staff concerning a matter on the agenda are included as supplemental material to the agendized item. These written communications are accessible to the public through the City's website and kept in packet archives. You are hereby admonished not to include any personal or private information in written communications to the City that you do not wish to make public; doing so shall constitute a waiver of any privacy rights you may have on the information provided to the City. Members of the public are entitled to address the members concerning any item that is described in the notice or agenda for this meeting, before or during consideration of that item. If you wish to address the members on any other item not on the agenda, you may do so during the public comment. Page 2 Cupertino, CA 95014 (408) 777-3308 ACTION MINUTES OF THE REGULAR MEETING OF TH E ADM I N ISTRATIVE HEARING HELD ON January 11, 2018 ROLL CALL Hearing Officer present: Catarina Kidd, Senior Planner Staff present: Erika Poveda, Assistant Planner Applicant(s) present: Nallely Garcia (GP Residential), agent for property owner APPROVAL OF MINUTES: 1. December 14, 2017 The minutes of December 14, 2017 were approved aswritten POSTPON EM ENTSiREM OVAL FROM CALENDAR: N one ORAL COMMUNICATIONS: N one WRITTEN COMMUNICATIONS: N one PUBLIC MEETING ITEM S- 2. Application No.(s): INT -2017-01 Applicant: Nallely Garcia (Vasavakul residence) Location: 1258 S. Stelling Road APN#s: 366-11-109 Front Yard Interpretation to designate the property linealong S. Stelling Road asthefront lot lineand to permit a 1,551 square foot addition to theexisting single -story, single-family residence. Administrative Hearing decision final unless appealed. 2 Administrative Hearing January 11, 2018 Staff Member Poveda addressed the Hearing Officer. The applicant's lot was annexed into Cupertino from San Jose in 1982. Per the City of Cupertino's Municipal Code, thefront lot line for corner lotsshould betheshortest line. In thiscasethat would bealong Rainbow Drive. The applicant would like to change thefront lot lineto bealong Stelling Road. Thiswould keep the property in conformance with the neighborhood, the current Municipal Code, and allow for their proposed addition to be within the setback areas. Staff supports this request as the City's Municipal Code allows these front lot line interpretations when doing so is best for the overall design relationship between thedeveloping lot and the neighborhood. The Hearing Officer asked for clarification about how the lot is non -conforming. Staff Member Poveda explained that per the Code, with Rainbow Drive as the front lot line, the rear yard setback is only 16 feet. But with the new designation of Stelling Road, the rear setback would be 24 feet. The Hearing Officer asked the applicant about the relationship between the trees and the side yard fence. She said that according to the drawings, it looked like there would be a void once the fence is moved to accommodate the new addition. The Hearing Officer asked if the applicant would be willing to install plantings in the side yard to fill this space. He said they would. The Hearing Officer opened the public comment period. Asthereweno speakers, the Hearing Officer closed the comment period. The Hearing Officer supported the project and felt that changing the front lot line designation was consistent with the neighborhood. DECISION: The application was approved by the Hearing Officer per the draft resolution with thefollowing additions/modifications: 1) That the side yard along Rainbow be planted above the retaining wall to use the newly exposed soil and for screening of thefence ADJOURNMENT Respectfully submitted: /s/Beth Ebben Beth Ebben Administrative Assistant g:planning/AH Committee/Minutes01112018 CUPERTINO SUBJECT OFFICE OF COMMUNITY DEVELOPMENT PLANNING DIVISION CITY HALL 10300 TORRE AVEN U E • CU PERTI N O, CA 95014-3255 (408) 777-3308 • FAX (408) 777-3333 ADMINISTRATIVE HEARING STAFF REPORT Agenda Date: February 8, 2018 Architectural and Site Approval to allow exterior building modifications to an existing building (Jack in the Box) and associated site improvements. (Application No(s).: ASA - 2017 -07; Applicant(s): Greg Borchardt (PM Design Group, Inc.); Location: 1451 South De An za Bou I evard ; A PN (s): 366-19-044, 366-19-045) RECOMMENDED ACTION That the Hearing Officer adopt thedraft resolution (Attachment 1) to: 1. Find that the proposed actions are exempt from CEQA; and 2. Approve the Architectural and Ste Approval Permit DISCUSSION: Application Summary: Architectural and Site Approval to allow exterior building and site modifications to an existing Jack in the Box. Project Data: General Plan Designation: Commercial/Office/Residential Special Area: South DeAnza Special Area Zoning Designation: P(CG, Residential 5-15) Lot Size: 22,314 square feet Existing Proposed Restaurant Area: 2,196 square feet 2,196 square feet Seating: 34 seats 36 seats Number of Employees: 7 em p oyees 7 em pl oyees Vehicular Parking: Required: N every 3 seats + 1 per employee) 19 spaces 19 spaces Bicycle Parking: Required: N per 2,000 sq. ft.) 3 spaces 4 spaces ASA -2017-07 Jack In The Box / 1451 South DeAnza Boulevard February 8, 2018 Page 2 Project Consistency with: General Plan: Yes Zoning: Yes Environmental Assessment: Categorically Exempt Background: Theproject siteislocated within the South DeAnza Special Areaon thesouthwest corner of South DeAnza Boulevard and Wildflower Way. The property isregulated by theSouth Saratoga -Sunnyvale Conceptual Zoning Plan. The South De Anza Special Plan Area is located on thewest sideof S. DeAnza Boulevard between Rainbow Dr. and Prospect Dr., and intended to remain a predominantly general commercial area with active retail and restaurant uses, as well as pedestrian scale elements. The city boundary shared by the citiesof Cupertino and San Jose runs in anorth-south direction down the centerline of S. DeAnza Boulevard between State Route 85 and Prospect Road. To the north of the property is a vacant retail building and asix-unit condominium development; to the west is a nursery (SummerWinds Nursery); to the south is a commercial showroom (Signature Kitchen and Bath Design) and to the east, across South De Anza Boulevard in the City of San Jose, is a retail building (Leslie's Pool Supplies) and other commercial buildings. The site is currently occupied by Jack in the Box, a fast food restaurant with a drive- through service. Since no operational changes are proposed, a Use Permit isnot required. Analysis: Applicant Req u est Theapplicant, Greg Borchardt (PM Design Group, Inc.) representing theproperty owner, Albert Tung, is requesting an Architectural and Site Approval for fagade modifications totheexisting Jack in the Box building. Theproject scopealso includessiteand landscape modifications (See Attachment 2.) ASA -2017-07 Jack In The Box/ 1451 South DeAnza Boulevard February 8, 2018 Page 3 Architectural and SiteApproval Facade Improvements: Theapplicant is proposing a new exterior fagadeto update the existing restaurant's 1960s era building. The new design will have a modular, contemporary feel that will enhance the experience of patrons and the appearance of the surrounding neighborhood. The existing mansard roof will be replaced with a new parapet wall around the entire building, consistent with newer and remodeled Jack in the Box locations regionally. The overall height will vary to give the building additional dimension, with an increase in height from 18'-0" to up to 20'-11" from theoriginal design. Thebrick veneer will remain and be painted with a new color palette, and new aluminum canopies will wrap the building to give the facade a more modern appearance. The parapet walls will have Light -emitting diode(LED) lightsthat aredown-lit and will wash thewall with light. Theexisting trash enclosureon thesitewill bemodified to include a cover/roof, and new waste receptacles are being provided, close to the public right of way, as required by the Environmental Services Division. Ste Improvements: Thesite hastwo main drivewaysfor ingress/egress: oneoff of S. DeAnza Boulevard (east driveway) and another off of Wildflower Way (north driveway.) There is also a one-way "Exit Only" driveway on to S. De Anza Boulevard for drive-through patrons. The applicant proposes to reduce the east driveway from 36 feet to 30 feet and the north driveway from 38 feet to 32 feet to conform to the City's Public Works standards for commercial driveway widths (minimum 24 feet, maximum 32 feet). A condition of approval has been added to ensure that this is completed prior to occupancy. A total of 19 parking spaces, 17 unisize and two accessible parking spaces, will be restriped in the parking lot. One additional bike parking spacewill also be provided to conform with the City's requirements. In addition, an accessible path -of -travel to the building is being provided from the public right of way, as required by the California Building Code. The Saratoga Sunnyvale Conceptual Plan requires the provision of a 50 -foot landscape easement (measured from curb line) along South De Anza Boulevard. A five foot sidewalk is required behind a minimum 10-15 feet of the landscape parkway strip. Additionally, a 25 -foot landscape area (measured from face -of -curb) is required along Wildflower Way. The applicant has proposed site improvements to satisfy these requ i rementsto the extent possible, given theexisting building location. A new landscape ASA -2017-07 Jack In The Box/ 1451 South DeAnza Boulevard February 8, 2018 Page 4 planter is proposed along the eastern property line and spans approximately 34feet from back of curb and up to 60 feet in length, with a new five foot sidewalk, behind an approximately nine and a half foot wide landscape parkway strip. Street dedication for the new sidewalk will be required and has been included asa condition of approval. The existing landscape planter on the north sidehasbeen widened an additional four feet, for a total width of approximately 16 and a half feet. These new and modified planters will feature new low-water use plants and trees. The applicant has proposed Crape Myrtletrees as part of the landscaping. The City's General Plan requires the planting of shade trees in the parking lot. While there are visibility concerns with the planting of larger shade trees at the corner of Wildflower Way and S. De Anza Blvd, and along S. De Anza Boulevard, it is possible to provide larger shade trees to replace the proposed crape myrtles in the northern planting area. This will not only provide shadewithin theparking lot but will also shield theresidential development across the street from light, glare and other similar issues. In addition, it is also possible to provide a planter in the right of way closer to the intersection of Wildflower Way and S. DeAnza Boulevard., on Wildflower Way. A condition of approval has been added to require both of these. Driveway Consolidation: The City's General Plan has several policies that emphasize improving the walk -ability and bike -ability within theCity. Policy M-3.5: Curb Cuts states "Minimize the number and the width of driveway openings." The General Plan also includes strategies to encourage shared driveway access within blocks where feasible. Additionally, the Saratoga - Sunnyvale Conceptual Zoning Plan also requires the consolidation of driveways where possible upon redevelopment, including facade remodels. In the interests of ensuring that the restaurant can operate efficiently, the City is not requiring consolidation of the north driveway with a driveway located immediately to its west (serving the Summerwinds Nursery to the west and properties to the south) at this time. In lieu of this, a condition of approval has been added to require recordation of a covenant which memorializes the property owner's agreement to consolidate the driveways, at a later date, if determined feasible by the City, when the City is able to require the same of the adjacent property, and enter into appropriate ingresslegress easements. Lot Merger: The site consists of two legal parcels - one that encompasses the majority of the lot (the building, parking area, and drive-through entry) (APN 366-19-044); and thesecond parcel that encompasses the drive-through, described in the property's title report as a "non- exclusive easement for ingress and egress, and for driveway purposes, appurtenant ASA -2017-07 Jack In The Box/ 1451 South DeAnza Boulevard February 8, 2018 Page 5 to ... Parcel One" (APN 366-19-045). Because there is no need for the easement to have a separate parcel and policies in the City's General Plan which encourage lot mergerswhen property is owned and controlled by the same entity, a condition of approval has been incorporated into thedraft resolution requiring the merger of the parcels into onesingle parcel prior to building permit issuance. Signs: Signage is not approved with this application. Signage shall conform to the City's Sign Ordinance (Chapter 19.104.) Other Department/Agency Review The City's Public Works Department, Building Division, Environmental Services Department, Santa Clara County Fire Department, and the Cupertino Sanitary District have reviewed the project and have no objections to the proposed plans. Their pre - hearing comments have been incorporated as conditions of approval in the draft resolutions. Environmental Review This project is categorically exempt from the requirements of the California Environmental Quality Act (CEQA, Section 15301 Existing Facilities). PUBLIC NOTICING AND COMMUNITY OUTREACH The following table is a brief summary of the noticing for this project: Notice of Public Hearing Agenda ■ Site Signage (at least 10 days prior to ■ Posted on the City's official notice hearing) bu I I eti n board (five days prior to ■ 15 notices mailed to property owners hearing) adjacent to the project site (at least 10 ■ Posted on the City of Cupertino's days prior to the hearing) Web site(five days prior to hearing) Staff has received no public comments on the project as of the date of production of this staff report (as of January 30, 2018). PERMIT STREAMLINING ACT This project is subject to the Permit Streamlining Act (Government Code Section 65920 — 65964). The City has complied with the deadlinesfound in the Permit Streamlining Act. Project Received: Ju I y 31, 2017; Deemed Incomplete: August 7, 2017 Project Revisions Received: August 21, 2017; Deemed Complete: September 14, 2017 ASA -2017-07 Jack In The Box/ 1451 South DeAnza Boulevard February 8, 2018 Page 6 Slncethis project is Categorically Exempt, the City typically has 60 days (until November 14, 2017) to make ad ecisi on on the project. However, the applicant has waived the Permit Stream I in i n g Act req u i rem ents per an em ai l dated .January 10, 2018 to al l ow sufficient time for plan modifications. The Administrative Hearing Officer's decision on this project is final unlessappealed within 14 calendar days of thedecision. CONCLUSION The proposed facade modifications and the proposed site modifications with the conditions of approval discussed above can be supported. Therefore, approval of the Architectural and Site Approval is recommended, since the plans and proposed conditions of approval addressall concernsrelated totheproposed project. Additionally, all of the findingsfor approval of the proposed project, consistent with Chapters 19.168 of the Cupertino Municipal Code, may be made as reflected in theDraft Resolution. NEXT STEPS The permit will be effective 14 calendar days from the date of the hearing. The decision of the Administrative Hearing Officer is final, unless appealed within 14 calendar days from the date of the hearing. The applicant may apply for building and/or other permits with the City at the end of the appeal period. This approval isvalid until February 8, 2020. The applicant may apply for a one-time one year extension before the approval expires. Prepared by: Jeffrey Tsumura, Assistant Planner Approved by: Piu Ghosh, Principal Planner ATTACHMENTS 1. Draft Resolution 2. Plan Set CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 DRAFT RESOLUTION OF TH E ADM I N ISTRATIVE HEARING OFFICER OF TH E CITY OF CUPERTINO TO ALLOW EXTERIOR BUILDING MODIFICATIONSTO AN EXISTING BUILDING (JACK IN THE BOX)AND ASSOCIATED SITE IM PROVEM ENTSAT 1451 SOUTH DEANZA BOULEVARD SECTION I: PROJECT DESCRIPTION Application No.: ASA -2017-07 Applicant: Greg Borchardt (PM Design Group, Inc.) Location: 1451 South DeAnza Boulevard (A PN s #366-19-044, 366-19-045) SECTION I I : FINDINGS WHEREAS, the Administrative Hearing Officer of the City of Cupertino received an application to allow an Architectural and Ste Approval to allow exterior building and site modifications to an existing Jack in the Box; WHEREAS, the project is categorically exempt from the California Environmental Quality Act (CEQA); and WHEREAS, the necessary public meeting notices have been given as required by the Procedural Ordinance of the City of Cupertino, and the Administrative Hearing Officer has held at least one public meeting in regard to the application; and WHEREAS, the Administrative Hearing Officer finds that: 1. The proposal will not be detrimental or injurious to property or improvements in thevicinity, and will not be detrimental to the public health, safety, general welfare, or convenience; The project is not detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience because the applicant is proposing a modification to the building facade without an increase in floor area and site improvements to enhance landscaping and ADA accessibility. The applicant is also reducing the size of the driveway curb cuts either as proposed or as a condition of Draft Resolution ASA -2017-07 February 8, 2018 Page 2 approval. This will improve the walkability and bikeability of the vicinity and also reduce the speed of cars entering or exiting the site, therefore, improving the general safety in the area. 2. The proposal is consistent with the purposes of Chapter 19.168, Architectural and Site Review, of the Cupertino Municipal Code, the General Plan, any specific plan, zoning ordinances, applicable planned development permit, conditional use permits, variances, subdivision maps or other entitlements to use which regulate the subject property including, but not limited to, adherence to the following specific criteria: a) Abrupt changes in building scale should be avoided. A gradual transition related to height and bulk should be achieved between new and existing buildings; The proposed facade modifications will result in a gradual transition in height between 1'4" to 2'-11" from the existing building height. The project does not increase the number of stories for the structure. The building is surrounded by single story structures on the west, south and east and has a taller single story commercial building and three story condominiums to the north. Therefore, the additional height due to the proposed facade modification is not abrupt and will be harmonious. The floor area of the building will remain unchanged. b) In order to preserve design harmony between new and existing buildings and in order to preserve and enhance property values, the materials, textures and colors of new buildingsshould harmonizewith adjacent development by being consistent or compatible with design and color schemes, and, with the future character of the neighborhood and purposes of the zone in which they are situated. The location, height and materials of walls, fencing, hedges and screen planting should harmonize with adjacent development. Unsightly storage areas, utility installations and unsightly elementsof parking Iotsshould beconcealed. Theplanting of ground cover or various types of pavements should be used to prevent dust and erosion, and the unnecessary destruction of existing healthy trees should be avoided. Lighting for development should be adequate to meet safety requirements as specified by the engineering and building departments, and provide shielding to prevent spill-over light to adjoining property owners; The facade modifications are harmonious with the existing buildings in the commercial shopping center and will not impact adjoining properties. The properties to the north have a more modern design ethic while the buildings to the south are much older. However, the proposed design maintains the brick veneer and adds modern elements to the roof/parapet. All rooftop equipment will be screened from view and a new enclosure and roof will be Draft Resolution ASA -2017-07 February 8, 2018 Page 3 added to the existing trash area. New lighting sources are shielded or down -lit and any adjacent residential properties will not be impacted. As a condition of approval, the applicant will be required to plant larger shade trees along the northern side of the property which will further alleviate any light pollution. New low-water use landscaping will be installed in the existing planter areas to provide visual relief of the parking area and enhance the overall site design. c) The number, location, color, size, height, lighting and landscaping of outdoor advertising signs and structures shall minimize traffic hazards and shall positively affect the general appearance of the neighborhood and harmonize with adjacent development; and Signage is not approved as part of this application and therefore, not reviewed in conjunction with this application. The property owner will submit a Master Sign Program at a later date and site signage will be reviewed at that time. d) With respect to new projects within existing residential neighborhoods, new development should be designed to protect residents from noise, traffic, light and visually intrusive effects by use of buffering, setbacks, landscaping, walls and other appropriate design measures. The project is an existing business and no changes to the building setbacks, hours, or operations are proposed. The project site is located in a Planned Development General Commercial/Residential zone, and is adjacent to a six -unit condominium development. However, the proposal includes new landscaping for enhanced screening from streets and neighboring properties. As a condition of approval, the applicant is required to plant larger shade trees along the northern side of the property to further protect residents from the light and other visually intrusive effects of the development. NOW, THEREFORE, BE IT RESOLVED: That after careful consideration of maps, facts, exhibits, testimony and other evidence submitted in this matter, the Hearing Officer finds that the proposed project is exempt from CEQA, and Application No. ASA -2017-07, is hereby approved; and That the subconclusions upon which the findings and conditions specified in this Resolution are based and contained in the public meeting record concerning Application ASA -2017-07 as set forth in the Minutes of the Administrative Hearing Meeting of February 8, 2017, and areincorporated by reference herein. Draft Resolution ASA -2017-07 February 8, 2018 Page 4 SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPARTMENT 1. APPROVED EXHIBITS Approval is based on the plan set dated September 22, 2016, by PM Design Group, Inc. consisting of eight (8) sheets titled, "Exterior Refresh Upgrade & Interior Remodel, 1451 South De Anza Blvd., Cupertino, CA 95014" except as may be amended by conditions in this resolution. 2. ACCURACY OF PROJECT PLANS The applicant/property owner is responsible to verify all pertinent property data including but not limited to property boundary locations, building setbacks, property size, building square footage, any relevant easements and/or construction records. Any misrepresentation of any property data may invalidate this approval and may require additional review. 3. ANNOTATION OF THE CON DITIONSOFAPPROVAL The conditions of approval set forth in this resolution shall be incorporated with completewritten annotated responses into the building permit submittal. 4. I N GRESSiEGRESS EA SEM ENT Prior to issuance of a Building Permit for the site, the property owner shall record a deed restriction agreeing to the consolidation of the driveway on Wildflower Way and enter into a Reciprocal Access Easement with the adjoining property owner(s), at such time in the future that the City can require the same of the adjoining property owner(s). The precise location of the consolidated driveway and/or easement(s) shall be determined by the City at the time that the adjoining property(ies) develop(s). Said agreement shall provide that the access be implemented (the expenses for which shall be borne by both parties) at such time as the City can require participation in shared accessof the other property owner through a Planning permit. 5. SITE DESIGN MODIFICATION The applicant shall ensure that the design of the proposed parking lot prior to issuance of encroachment and/or building permits satisfies the following requirements, subject to review and approval by the Directors of Community Development and Public Works: a. The driveway widths on South De Anza Boulevard and Wildflower Way conform to the City Standard Details and are consistent with the Public Works standardsof no morethan 32feet in width. Draft Resolution ASA -2017-07 February 8, 2018 Page 5 b. Provide one additional landscape planter in the right of way along Wildflower Way, wheredetermined to befeasibleby the City to separate the sidewalk. c. Expand the existing landscape areas to the greatest extent possible in conformance with the standards in the Saratoga -Sunnyvale Conceptual Zoning Plan. The final design shall be reviewed and approved to the satisfaction of the Community Development Director. 6. LOTLINEADJUSTMENT Prior to issuance of a Building Permit for the site, a Lot Line Adjustment shall be filed through the Public Works Department to merge the two parcels on the property into one single parcel. 7. LAN DSCAPE PLAN The final landscaping plan shall be reviewed and approved by the Planning Division prior to issuance of building permits. If the landscape area (defined by section 14.15.030) exceeds 2,500 square feet, then a full landscape project submittal per section 14.15.040 is required prior to issuance of building permits. The final landscape plan shall be updated to replace the proposed Crape Myrtle (Lagerstroemia`Cherokee')with treesthat providea larger shadecanopy, including, but not limited to, up to threewith Crape Myrtle (Lagerstroemia `Muskogee'). 8. SIGNAGE Signage is not approved with this use permit application. Signage shall conform to the City Sign Code. 9. CONSULTATION WITH OTHER DEPARTMENTS The applicant is responsible to consult with other departments and/or agencies with regard to the proposed project for additional conditions and requirements. Any misrepresentation of any submitted data may invalidate an approval by the Community Development Department. 10. EXTERIOR BUILDING MATERIALSITREATMENTS Final building exterior treatment plan (including but not limited to details on exterior color, material, architectural treatments and/or embellishments) shall be reviewed and approved by the Director of Community Development prior to issuance of building permits. The final building exterior plan shall closely resemble thedetailsshown on theoriginal approved plans. Any exterior changes determined to be substantial by the Director of Community Development shall require a minor modification approval with neighborhood input. Draft Resolution ASA -2017-07 February 8, 2018 Page 6 11. INDEMNIFICATION Except as otherwise prohibited by law, the applicant shall indemnify and hold harmless the City, its City Council, and its officers, employees and agents (collectively, the "indemnified parties") from and against any claim, action, or proceeding brought by a third party against one or more of the indemnified partiesor one or more of the indemnified partiesand the applicant to attack, set aside, or void this Resolution or any permit or approval authorized hereby for the project, including (without limitation) reimbursing the City its actual attorneys' fees and costs incurred in defense of the litigation. Theapplicant shall pay such attorneys' fees and costswithin 30 daysfollowing receipt of invoices from City. Such attorneys' fees and costs shall include amounts paid to counsel not otherwise employed as City staff and shall include City Attorney time and overhead costs and other City staff overhead costs and any costs directly related to the litigation reasonably incurred by City. 12. NOTICE OF FEES, DEDICATIONS, RESERVATIONS OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90 -day approval period in which you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90 -day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. SECTION IV: CONDITIONS ADMINISTERED BY THE PUBLIC WORKS D EPA RTM EN T 13. TRASH, RECYCLING AND COMPOST RECEPTACLES The developer is required to install public bins (-30 gal) side-by-side for trash, recycling and composting, adjacent to the development to control pedestrian litter at the site. The type and location of the receptacles are subject to the approval of the Environmental Programs Manager. (CMC 9.18.210 P) 14. TRASH, RECYCLING AN D COM POST ENCLOSURES The existing trash enclosure must be sized in accordance the City's "Public Works Guidelines for Non -Residential Building Trash & Recycling Enclosures" posted at www.cupertino.org/nowaste. Modifications to existing facilities shall, to the maximum extent practicable, meet the Public Works Guidelines and shall be subject Draft Resolution ASA -2017-07 February 8, 2018 Page 7 to the approval of the Public Works Director. Clearance by the Public Works Department is required prior to obtaining a building permit. (CMC 9.18.210 H & K) 15. TRA SH FU L L CA PTU RE STORM DRAIN CATCH BASIN INSERTS For projects located in medium and high trash management areas as defined by the City of Cupertino Trash Management Area Map or are adjacent to a creek, trash full capturestorm catch basin insertsmay berequired. 16. STORM DRAIN INLET MARKERS All exterior storm drain inlets on the property shall be clearly marked with "No Dumping Flowsto Creek" or "No Dumping Flowsto Bay". 17. STREET IMPROVEMENTS The applicant shall provide a street improvement plan along the project frontages to the satisfaction of the Director of Public Works. Curbs, gutters, sidewalks, driveway approaches, and related structures shall be installed in accordance with grades and standards as specified by the City Engineer. 18. DRAINAGE Drainage shall be provided to the satisfaction of the City Engineer. Pre- and post - development calculations must be provided to indicate whether additional storm water control measures are to be installed. Onsite drainage shall be shown on the site plan with direction and slope percentage. 19. IM PROV EM ENT A G REEM ENT The project developer shall enter into a developer agreement with the City of Cupertino providing for payment of fees including, but not limited to, checking and inspection fees, storm drain fees, park dedication fees, and fees for the undergrounding of utilities. Said agreement shall be executed prior to issuance of construction permits. Fees: a. Checking and Inspection Fees: b. Storm Drainage Fee: C. Power Cost: Per current fee schedule ($3,349.00 or 5% of improvement costs) Per current fee schedule ($8,790 per AC) Based on latest effective PG&E rate schedule approved by the PUC Bonds: Faithful Performance Bond: 100% of off-site and on-site improvements Labor and Material Bond: 100% of off-siteand on-site improvements On-site Grading Bond: 100% of site improvements Draft Resolution ASA -2017-07 February 8, 2018 Page 8 The fees described above are imposed based upon the current fee schedule adopted by the City Council. However, the fees imposed herein may be modified at the time of recordation of a final map or issuance of a building permit. In the event of said change or charges, the fees changed at that time will reflect the then current fee sch ed u I e. 20. OPERATI ON S & M A I N TEN A N CE A GREEM EN T The applicant shall enter into an Operations & Maintenance Agreement with the City prior to final occupancy. The agreement shall include the operation and maintenance for non-standard appurtenances in the public road right-of-way that may include, but isnot limited to, sidewalks, pavers, and street lights. 21. WATER BACKFLOW PREVENTERS Domestic and Fire Water Backflow preventers and similar above ground equipment shall be placed away from the public right-of-way and site driveways to a location approved by the Cupertino Planning Department, Santa Clara County Fire Department and the water company. 22. BEST MANAGEMENT PRACTICES Utilize Best Management Practices (BM Ps), as required by the State Water Resources Control Board, for construction activity, which disturbs soil. BMP plans shall be included in grading and street improvement plans. 23. TRA FFI C CONTROL PLAN The applicant must submit a traffic control plan by a Registered Traffic Engineer to be approved by the City. The Plan shall include a temporary traffic control plan for work in the right-of-way as well as a routing plan for all vehicles used during construction. All traffic control signs must be reviewed and approved by the City prior to commencement of work. The City has adopted Manual on Uniform Traffic Control Devices (M UTCD) standards for all signage and striping work throughout the City. 24. STREET TREES Street trees shall be planted within the public right-of-way to the satisfaction of the Director of Public Works and shall be of a type approved by the City in accordance with Ordinance No. 125. 25. FIRE PROTECTION Fire sprinklers shall be installed in any new construction to the approval of the City. Draft Resolution ASA -2017-07 February 8, 2018 Page 9 26. DEDICATION OF NEWS D EWA LK The dedication in fee title will be required to incorporate the new sidewalk and associated improvements. Prior to Building permit issuance, the applicant shall provide a plat and legal description prepared by a Licensed Land Surveyor or qualified Civil Engineer. The City will provide the dedication language to be signed by the property owner and recorded with the County. 27. DEDICATION OF UNDERGROUND WATER RIGHTS The applicant shall "quit claim" to the City all rights to pump, take, or otherwise extract water from the underground basin or any underground strata in the Santa Clara Valley. PASSED AND ADOPTED this 8t" day of February, 2018 at a noticed Public Meeting of the Administrative Hearing Officer of the City of Cupertino, Stateof California, held by the Director of Community Development, or his or her designee, pursuant to Cupertino Municipal Code Section 19.12.120. ATTEST: Jeffrey Tsumura Assistant Planner APPROVED: Benjamin Fu Asst. Director of Community Development LEGEND & ABBREVIATIONS STORE #0490 MARK 5F 48 SHEET INDEX TS1.01 TITLE SHEET rT D1.0 SITE PLAN D1.1 SITE PLAN - DETAILS 1.0 PHOTO LANDSCAPE PLAN EXTERIOR REFRESH UPGRADE & INTERIOR REMODEL ALSO REFER TO LEGEND & ABBREVIATIONS ON CIVIL, SITE, PLUMBING, MECHANICAL, ELECTRICAL & KITCHEN DRAWINGS. gtin Cb/, rho & AND MAT. MATERIAL 4 Bltid - Cn 0 AT MAX. MAXIMUM �5s N A.B. ANCHOR BOLT M.B. MACHINE BOLT P �{ ASPHALTIC CONCRETE MECH. MECHANICAL DA.C. INDICATES SHEARWALL LOCATIONS WHERE A.C.I. AMERICAN CONCRETE INSTITUTE MEZZ. MEZZANINE NO CONDUIT OR PIPING WILL BE PERMITTED ACP ACOUSTIC CEILING PANEL MFR. MANUFACTURER TO PENETRATE SILL OR TOP PLATE. SEE A.D.A.A.G. AMERICANS WITH DISABILITIES ACT MIN. MINIMUM PLANS FOR ADDITIONAL NOTES. ACCESSIBILITY GUIDELINES MISC. MISCELLANEOUS A.F.F. or AFF ABOVE FINISH FLOOR MPH MILES PER HOUR ® ALUM. ALUMINUM M.P.S. MODULAR PANELBOARD BATT INSULATION A.P.A. AMERICAN PLYWOOD ASSOCIATION SYSTEM A.Q.T. ABRASIVE QUARRY TILE M.S.B. MAIN SWITCH BOARD ARCH. ARCHITECTURAL MTL. METAL ® RIGID INSULATION A.S.T.M. AMERICAN SOCIETY FOR TESTING MATERIALS (N) NEW NO. or # NUMBER BLK'G or BLKG BLOCKING N.I.C. NOT IN CONTRACT GYPSUM BOARD B.N. BOUNDARY NAIL N.T.S. NOT TO SCALE A.O. BOTTOM OF BM. BEAM O.C. ON CENTER CERAMIC AND QUARRY TILE B.O.J. BOTTOM OF JOIST O.F.C.I. OWNER FURNISHED, B.U.R. BUILT UP ROOFING CONTRACTOR INSTALLED BOTT. or (B) BOTTOM O.F.0.1. OWNER FURNISHED, ® OWNER INSTALLED PLYWOOD C CONDUIT O.H. OPPOSITE HAND C.L. or CENTER LINE OPNG. OPENING C.B.B. CEN S BACKER BOARD CONCRETE C.D. CORE DRILL P.C. PLUMBING CONTRACTOR C.J. CONTROL JOINT (COLD JOINT) PERP. PERPENDICULAR CLG. CEILING P. LAM PLASTIC LAMINATE OR ® MASONRY CLR. CLEAR PARALLAM (BEAM) C.M.U. CONCRETE MASONRY UNIT PL. PLATE COL. COLUMN P.L. PROPERTY LINE ® CON. CONCRETE PPLYWOOD ASPHALTIC CONCRETE PAVING CONN. CONNECTION POSOS or P.O.S. POINT OF SALE CONST. CONSTRUCTION PR. PAIR CONST. JT. CONSTRUCTION JOINT PSF. POUNDS PER SQ. FOOT =III-III-III=11 EARTH GRADE CONT. CONTINUOUS PSI. POUNDS PER SQ. INCH III-III=III-III CONTR. CONTRACTOR P.T. PRESSURE TREATED COMP COMPACTED (ION) C.T. CERAMIC TILE Q.T. QUARRY TILE SAND BASE QTY. or QTY QUANTITY DBL. DOUBLE DEG. or ' DEGREE RAD.OR (R) RADIUS KITCHEN ROOM NAME DIA. or 0 DIAMETER REINF. REINFORCEMENT 110 ROOM NUMBER DIM• DIMENS ON DIAGONAL R.O. ROUGH ORIENTATION DR. DOOR S.C. SAW -CUT JOINT DWG.(S) DRAWING(S) SCHED. SCHEDULE 128 FINISHES & EQUIPMENT SEE ID DRAWINGS SHT. SHEET (E) EXISTING SIM. SIMILAR EA. EACH SM SHEET METAL E.C. ELECTRICAL CONTRACTOR SMS SHEET METAL SCREW E.F. EACH FACE SPEC -(S) SPECIFICATION(S) 100 EQUIPMENT, SEE KITCHEN DRAWING SQ. SQUARE EL. or ELEV. ELEVATION E.N. EDGE NAIL SQ. IN. SQUARE INCH E.O.C. EDGE OF COUNTER / EDGE OF SQ. FT. SQUARE FOOT 00 EXTERIOR MATERIAL / FINISH EQUIPMENT S.S. STAINLESS STEEL ELEC. ELECTRICAL STD. STANDARD AA EXTERIOR COLOR STL. STEEL EQ. or = EQUAL EQUIP. EQUIPMENT STRUCT. STRUCTURAL 1 E.S. EACH SIDE SUSP. SUSPENDED EXP. EXPANSION S.W. SHEARWALL 4 A7.0 2 INTERIOR ELEVATION EXT. EXTERIOR SYM. SYMMETRICAL FACT. FACTORY (T) TOP 3 F.D. FLOOR DRAIN TEMP. TEMPERED (TEMPERATURE) FDN. FOUNDATION T.G. TEMPERED GLASS F.F. FINISHED FLOOR THK. THICKNESS 101 DOOR SYMBOL F.F.L. FINISHED FLOOR LEVEL T & G TONGUE & GROOVE F.G. FLOAT GLASS T.N. TOE NAIL FLR. FLOOR T.O. TOP OF FIN. FINISH T.O.B. TOP OF BEAM O KEY NOTES F.N. FIELD NAIL T.O.C. TOP OF CURB F.O.B. FACE OF BEAM T.O.F. TOP OF FOOTING F.O.F. FACE OF FINISH T.O.PL. TOP OF PLATE F.O.J. FACE OF JOIST T.O.S. TOP OF SLAB OA F.O.M. FACE OF MASONRY T.O.W. TOP OF WALL SHEARWALL ANCHOR BOLT SYMBOL / F.O.P. FACE OF POST TYP. TYPICAL F.O.S. FACE OF STUD F.R.P. FIBERGLASS REINFORCED PANEL U.B.C. UNIFORM BUILDING CODE F.S. FLOOR SINK U.O.N. UNLESS OTHERWISE NOTED F-1 FOOTING SYMBOL FT. FOOT or FEET U.S.P. UNDER SEPARATE PERMIT FTG. FOOTING VERT. OR (V) VERTICAL GA. or GA GAUGE (GAGE) V.W.C. VINYL WALLCOVERING 2 DETAIL NUMBER G.B. or GYP. BD. GYPSUM BOARD SHEET NUMBER G.C. GENERAL CONTRACTOR W/ WITH A7.0 GALV. GALVANIZED WD. WOOD G.I. GALVANIZED IRON W.G.B. WATER RESISTANT GYPSUM GLB. GLUE -LAMINATED BEAM BOARD W.I.B. WALK-IN or WALK IN BOX 1 WALL SECTION NUMBER / ELEV. NUMBER H.D. HUB DRAIN WT. WEIGHT S5.0 SHEET NUMBER HDR. HEADER WWM. WELDED WIRE MESH HDW. HARDWARE HGR. HANGER HGT. or HT. HEIGHT 1 BUILDING SECTION NUMBER H.M. HOLLOW METAL SHEET NUMBER HORIZ. or H HORIZONTAL A6.0 H.S.B. HIGH STRENGTH BOLT I.B.C. INTERNATIONAL BUILDING CODE I.D. INTERIOR DESIGN 1 REVISION SYMBOL IN. INCH INFO. INFORMATION ELEVATION DATUM MARK INT. INTERIOR / INV. INVERTED JT. or JNT JOINT Ilk DIMENSION TO EDGE / FACE OF OBJECT JIB or J.I.B. Jack in the Box, Inc. JST. JOIST L ANGLE DIMENSION TO CENTER LINE OF OBJECT LG or LB or #POUNDS LG. LONG 1451 SOUTH DE ANZA BLVD. CUPERTINO, CA 95014 GENERAL NOTES 1. IN THE EVENT OF DISCREPANCIES BETWEEN THE DRAWINGS OR SPECIFICATIONS, IN THIS PACKAGE, NOTIFY ARCHITECT IMMEDIATELY. 2. ARCHITECT SHALL NOT BE RESPONSIBLE OR HAVE CONTROL OR CHARGE OVER ACTS OR OMISSIONS, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR THE SAFETY PRECAUTIONS & PROGRAMS OF THE CONTRACTOR, SUBCONTRACTOR, OR ANY OTHER PERSONS PERFORMING WORK ON THE PROJECT. 3. ARCHITECT HAS NOT BEEN RETAINED FOR REVIEW, SUPERVISION OR ADMINISTRATION OF THE CONTRACT, NOR CERTIFICATION OF PAYMENTS, CONSTRUCTION COORDINATOR SHALL BE OWNER'S REPRESENTATIVE DURING CONSTRUCTION & UNTIL FINAL PAYMENT IS MADE. THE OWNER'S REPRESENTATIVE WILL REVIEW THE PROJECT & RENDER NECESSARY DECISIONS FOR THE PROGRESS OF THE WORK. 4. CONTRACTOR IS RESPONSIBLE TO SEE THAT WORK IN THE FIELD IS DONE IN ACCORDANCE WITH ALL CURRENT APPLICABLE NATIONAL, STATE, AND LOCAL CODES, ORDINANCES, AND REQUIREMENTS BY THE GOVERNING AGENCIES, WHETHER OR NOT SAID CODES, ORDINANCES, REQUIREMENTS, ETC ARE SPECIFICALLY SHOWN ON THE DRAWINGS AND/OR CALLED FOR IN THE SPECIFICATIONS. 5. CONTRACTOR SHALL PROTECT ALL EXISTING ITEMS AND FACILITIES TO REMAIN THROUGHOUT CONSTRUCTION, CONTRACTOR SHALL REPAIR AND/OR REPLACE, AT CONTRACTOR'S EXPENSE, ANY EXISTING ITEMS AND FACILITIES TO REMAIN THAT ARE DAMAGED BY CONTRACTOR'S OPERATIONS TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE. 6. GENERAL CONTRACTOR SHALL COORDINATE THE DELIVERY OF ALL OWNER SUPPLIED EQUIPMENT. THE CONTRACTOR IS RESPONSIBLE FOR INSPECTION OF EQUIPMENT AT THE TIME OF DELIVERY AND SHALL NOTIFY EQUIPMENT SUPPLIER OR ANY DEFICIENCIES OR DAMAGED EQUIPMENT AND ARRANGE FOR REPLACEMENT. 7. PRIOR TO EXCAVATION, DETERMINE AND VERIFY LOCATION OF UTILITY SERVICES IN ALL AREAS TO BE EXCAVATED. 8. CONTRACTOR SHALL COMPLY WITH ALL PERTINENT LAWS, CODES, REGULATIONS, GOVERNING AGENCIES AND MANUFACTURE SPECIFICATION, UNLESS GREATER REQUIREMENTS ARE INDICATED, OR ARE NECESSARY FOR SAFE WORKING CONDITIONS. 9. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING JURISDICTIONS AS REQUIRED FOR INSPECTIONS AND SHALL PAY INSPECTION FEES ASSOCIATED WITH THE WORK. 10. ARCHITECT SHALL APPLY FOR ELECTRICAL, HVAC MECHANICAL, AND PLUMBING PERMITS. 11. ARCHITECT, SHALL APPLY FOR ALL PERMITS WHICH INVOLVE DRAWING SUBMITTAL AND PROCESSING, BUILDING, FIRE, AND ENVIRONMENTAL HEALTH. 12. THE GENERAL CONTRACTOR SHALL PROVIDE THE OWNER'S ENGINEER WITH A CONSTRUCTION SCHEDULE PRIOR TO STARTING THE WORK, SHALL PROVIDE A QUALIFIED JOB SUPERINTENDENT THROUGHOUT THE WORK, AND PROVIDE THE OWNER WITH PHOTOS SHOWING PIPING AND ELECTRICAL TRENCHES PRIOR TO BACK FILL, AND SHALL PROVIDE A SET OF "AS BUILT" MARKUPS AT COMPLETION. 13. THE GENERAL CONTRACTOR SHALL PROVIDE BARRICADES AND SAFETY SIGN PER OSHA REQUIREMENTS. 14. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OVERALL CONSTRUCTION SITE CLEANLINESS, INCLUDING PROVISIONS OF A DEBRIS BOX WITH REGULAR SERVICING, REMOVAL OF ALL CONTRACTOR REFUSE AND DEBRIS, AND SWEEPING OF THE ENTIRE YARD AREA AT COMPLETION OF THE WORK. 15. ALL PROCEDURES, TESTING, MATERIALS, LABOR, AND EQUIPMENT SHOWN ON THE PLANS SHALL BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR, UNLESS NOTED OTHERWISE IN THESE PLANS, EQUIPMENT OR MATERIALS NOTED ONLY AS "FURNISHED BY OWNER" SHALL BE INSTALLED BY THE GENERAL CONTRACTOR. 16. CONTRACTORS SHALL NOT SCALE THESE DRAWINGS FOR CONSTRUCTION PURPOSES, IN THE EVENT OF OMISSION OF NECESSARY DIMENSIONS THE CONTRACTORS SHALL NOTIFY THE ARCHITECT. 17. ERRORS AND/OR OMISSIONS IN THE SCHEDULES DOES NOT RELIEVE THE CONTRACTOR FROM EXECUTING THE WORK SHOWN ON THE DRAWINGS OR DESCRIBED IN THE SPECIFICATIONS. 18. NO HAZARDOUS MATERIALS WILL BE STORED AND/OR USED WITHIN THE BUILDING WHICH WILL EXCEED THE QUANTITIES LISTED IN THE CBC TABLE 307.1 (1) AND 307.1(2). VICINITY MAP FL ShadowhiII Lna �[ GM11 Dr C a - 4 �¢mllow Dr 0 Rainbow Dr Rainbow Dr Rainbow Dr � 0 > ,a v h� Rainbow 0' Orange Blossom Dr o P1 rf� Peach Blossom Dr O Yamagsml's Nursery Normandy Way It � yVIydffowerWay <n Jack in the Bax d Newcastle Dr T N a o L_ .a t c Sharon Or � Waterrarl� I'.. SL SITE LOCATION halal Meats W Saratoga Plaza u, 4onccpI Dr Ao Shopping Center 0 m parnharl PI o, �a CL Prospeci Rdprospect Rd Prospect Rd mm ti Br Mer da or .., p F ,a, r� n Proslaecr Rd m ,%(ioor Way ra v Devon Way A1.0 FLOOR PLAN A3.0 ROOF PLAN A4.0 EXTERIOR ELEVATIONS A4.1 EXTERIOR ELEVATIONS PROJECT DESCRIPTION JACK IN THE BOX IS PROPOSING TO REMODEL AN EXISTING 2,196 S.F. BUILDING WITH AN EXISTING DRIVE THRU. PROJECT IS MAINTAINING EXISTING OCCUPANCY AND CURRENT USE. THE PROJECT CONSISTS OF NEW EXTERIOR PAINT UPGRADE OF THE EXISTING "JACK IN THE BOX". NEW EXTERIOR WALL LIGHTING WILL BE ADDED TO NEW PARAPET. STRUCTURAL RETROFIT AND NEW ROOF. THE PROJECT ALSO CONSISTS OF IN INTERIOR REMODEL: ADA COMPLIANT RESTROOMS, NEW DINING ROOM SEATING AND FINISHES, NEW FINISHES IN RESTROOMS, NEW LED LIGHTING THROUGHOUT BUILDING. HOURS OF OPERATION ARE 6:30AM-2:OOAM FOR THE DINING ROOM, AND 24 HR. OPERATION FOR THE DRIVE-THRU. TOTAL NUMBER OF EMPLOYEES: ±45 TOTAL NUMBER OF EMPLOYEES ON LARGEST SHIFT: 8 UNDER SEPARATE PERMIT 1. ALL NEW BUILDING SIGNAGE. CONSULTANT INFORMATION TITLE SHEET SITE ARCHITECTURAL (TOTAL OF 8 SHEETS) i n the box 9330 BALBOA AVENUE SAN DIEGO, CA 92123 © 2007 Jack in the Box Inc. These designs, drawings and specifications are the property of Jack in the Box Inc and shall not be copied or reproduced without its previous written consent. These drawings attached are intended to assist the architect in preparing site-odapt construction documents provided that such use does not conflict with rules governing architects in the state where the work is to be performed. They will need to be modified to comply with all applicable codes and site-specific conditions. DATES RELEASE: AUG. 24, 2015 P.M. UPDATES: SEPT. 22, 2016 SUBMITTAL DATE: 2: 3: BID: CONSTRUCTION: REVISIONS Comments from Planning and Public Works 5/4/11 ZL Comments from Planning and Public Works 1/12/11 0 0 ARCHITECT: BUILDING OWNER: PM DESIGN GROUP, INC. JIB RESTRAUANT GROUP, INC. ROY PEDRO, ARCHITECT PHILIP HSIA 6930 DESTINY DR., SUITE 100 1451 SOUTH DE ANZA BLVD. ��SED A RC y�T ROCKLIN, CA 95677 CUPERTINO, CA 95014 PE�� FOS PHONE: (916) 226-5487 PHONE: (408) 255-3126 CONTACT: DAVID LUNDY philip.hsia®gmail.com C-28504 dlundy@pmdginc.com REN. 1/31/19 MEP ENGINEER: STRUCTURAL ENGINEER: �T�TFOF CP,0 0 \� ROBISON ENGINEERING CULLUMBER ENGINEERING PAUL ROBISON, PRINCIPAL WESLEY CULLUMBER, S.E. 20300 19TH AVENUE NE 6930 DESTINY DR., SUITE 300 SHORELINE, WA 98155 ROCKLIN, CA 95677 PHONE: (206) 364-3343 PHONE: (916) 251-9798 FAX: (206) 364-3363 BUILDING DATA OWNER: Jack in the Box Inc. (J.I.B.) DESIGN JACK IN THE BOX # 0490 BUILDING ADDRESS: 1451 SOUTH DE ANZA DLVD. A r c h i t e c t u r 1 CUPERTINO, CA 95014 Solutions G r o I!j n LEGAL JURISDICTION: CITY OF CUPERTINO, SANTA CLARA COUNTY, 6930 DESTINY DRIVE STATE OF CALIFORNIA SUITE 100 ROCKLIN, CA 95677 PLANNING ZONE: P (CG, RES 5-15) ASSESSOR'S PARCEL NO. 366-19-044 (916)415-5358 rpedro@pmdginc.com MUNICIPAL CODES: 2016 CALIFORNIA ADMINISTRATIVE CODE 2016 CALIFORNIA BUILDING CODE Roy W. Pedro, Architect 2016 CALIFORNIA ELECTRICAL CODE 2016 CALIFORNIA MECHANICAL CODE 2016 CALIFORNIA PLUMBING CODE 2016 CALIFORNIA ENERGY CODE SITE INFORMATION 2016 CALIFORNIA FIRE CODE 2016 CALIFORNIA GREEN CODE STANDARDS AND ALL MK TYPE: MK5F_48 APPLICABLE LOCAL AND STATE LAWS AND REGULATIONS JIB #: 0490 EXISTING BUILDING AREA: ±2,236 S.F. (EXISTING). ADDRESS: BUILDING HEIGHT: 1 STORY, 20'-11" 1 451 S. DE ANZA BLVD TOTAL SITE AREA: ±22,314 S.F. CUPERTINO, CA 95014 EXISTING SEATING: 34 SEATS PROPOSED SEATING: 36 SEATS DRAWN BY: OCCUPANCY: A-2 - RESTAURANT (EXISTING) PROJECT #: JRG17001.0 TYPE OF ONSTRUCTION: V -B NON-SPRINKLERED) SCALE: AS NOTED PARKING REQUIREMENTS: 1 PER 3 SEATS = 12 SPAC S 1 PER EMPLOYEE = 7 SPACES TITLE 1 BIKE RACK PER 2000 S.F. FLOOR SPACE = 2 RACKS EXISTING: 19 TOTAL G SPACES (g PACES, 1 ADA ACCESSIBLE PARKING SPACE) SHEET 4 EXISTING BIKE RACKS PROVIDED. PROPOSED: NO CHAN S HOURS OF OPERATION: 6:30AM-2:OOAM FOR DINING AREA 24 HOUR FOR DRIVE-THRU TS1 mO 0 �7 0India Cash And Carry V1 V4 Vu c V gtin Cb/, rho M m Blue Hill Dr Blue 1.1111 or 4 Bltid - Cn n HollnnderryPI Q 65CBakery0 = Vim CallinaApaftments �5s N Cafe - San Jose f"hylysAve P �{ Kingsbury P' h3 Barlk Ln Bark Ln . C r Bedand ct N y o m �r Coronado Dr Calabasas Park Ca FL ShadowhiII Lna �[ GM11 Dr C a - 4 �¢mllow Dr 0 Rainbow Dr Rainbow Dr Rainbow Dr � 0 > ,a v h� Rainbow 0' Orange Blossom Dr o P1 rf� Peach Blossom Dr O Yamagsml's Nursery Normandy Way It � yVIydffowerWay <n Jack in the Bax d Newcastle Dr T N a o L_ .a t c Sharon Or � Waterrarl� I'.. SL SITE LOCATION halal Meats W Saratoga Plaza u, 4onccpI Dr Ao Shopping Center 0 m parnharl PI o, �a CL Prospeci Rdprospect Rd Prospect Rd mm ti Br Mer da or .., p F ,a, r� n Proslaecr Rd m ,%(ioor Way ra v Devon Way A1.0 FLOOR PLAN A3.0 ROOF PLAN A4.0 EXTERIOR ELEVATIONS A4.1 EXTERIOR ELEVATIONS PROJECT DESCRIPTION JACK IN THE BOX IS PROPOSING TO REMODEL AN EXISTING 2,196 S.F. BUILDING WITH AN EXISTING DRIVE THRU. PROJECT IS MAINTAINING EXISTING OCCUPANCY AND CURRENT USE. THE PROJECT CONSISTS OF NEW EXTERIOR PAINT UPGRADE OF THE EXISTING "JACK IN THE BOX". NEW EXTERIOR WALL LIGHTING WILL BE ADDED TO NEW PARAPET. STRUCTURAL RETROFIT AND NEW ROOF. THE PROJECT ALSO CONSISTS OF IN INTERIOR REMODEL: ADA COMPLIANT RESTROOMS, NEW DINING ROOM SEATING AND FINISHES, NEW FINISHES IN RESTROOMS, NEW LED LIGHTING THROUGHOUT BUILDING. HOURS OF OPERATION ARE 6:30AM-2:OOAM FOR THE DINING ROOM, AND 24 HR. OPERATION FOR THE DRIVE-THRU. TOTAL NUMBER OF EMPLOYEES: ±45 TOTAL NUMBER OF EMPLOYEES ON LARGEST SHIFT: 8 UNDER SEPARATE PERMIT 1. ALL NEW BUILDING SIGNAGE. CONSULTANT INFORMATION TITLE SHEET SITE ARCHITECTURAL (TOTAL OF 8 SHEETS) i n the box 9330 BALBOA AVENUE SAN DIEGO, CA 92123 © 2007 Jack in the Box Inc. These designs, drawings and specifications are the property of Jack in the Box Inc and shall not be copied or reproduced without its previous written consent. These drawings attached are intended to assist the architect in preparing site-odapt construction documents provided that such use does not conflict with rules governing architects in the state where the work is to be performed. They will need to be modified to comply with all applicable codes and site-specific conditions. DATES RELEASE: AUG. 24, 2015 P.M. UPDATES: SEPT. 22, 2016 SUBMITTAL DATE: 2: 3: BID: CONSTRUCTION: REVISIONS Comments from Planning and Public Works 5/4/11 ZL Comments from Planning and Public Works 1/12/11 0 0 ARCHITECT: BUILDING OWNER: PM DESIGN GROUP, INC. JIB RESTRAUANT GROUP, INC. ROY PEDRO, ARCHITECT PHILIP HSIA 6930 DESTINY DR., SUITE 100 1451 SOUTH DE ANZA BLVD. ��SED A RC y�T ROCKLIN, CA 95677 CUPERTINO, CA 95014 PE�� FOS PHONE: (916) 226-5487 PHONE: (408) 255-3126 CONTACT: DAVID LUNDY philip.hsia®gmail.com C-28504 dlundy@pmdginc.com REN. 1/31/19 MEP ENGINEER: STRUCTURAL ENGINEER: �T�TFOF CP,0 0 \� ROBISON ENGINEERING CULLUMBER ENGINEERING PAUL ROBISON, PRINCIPAL WESLEY CULLUMBER, S.E. 20300 19TH AVENUE NE 6930 DESTINY DR., SUITE 300 SHORELINE, WA 98155 ROCKLIN, CA 95677 PHONE: (206) 364-3343 PHONE: (916) 251-9798 FAX: (206) 364-3363 BUILDING DATA OWNER: Jack in the Box Inc. (J.I.B.) DESIGN JACK IN THE BOX # 0490 BUILDING ADDRESS: 1451 SOUTH DE ANZA DLVD. A r c h i t e c t u r 1 CUPERTINO, CA 95014 Solutions G r o I!j n LEGAL JURISDICTION: CITY OF CUPERTINO, SANTA CLARA COUNTY, 6930 DESTINY DRIVE STATE OF CALIFORNIA SUITE 100 ROCKLIN, CA 95677 PLANNING ZONE: P (CG, RES 5-15) ASSESSOR'S PARCEL NO. 366-19-044 (916)415-5358 rpedro@pmdginc.com MUNICIPAL CODES: 2016 CALIFORNIA ADMINISTRATIVE CODE 2016 CALIFORNIA BUILDING CODE Roy W. Pedro, Architect 2016 CALIFORNIA ELECTRICAL CODE 2016 CALIFORNIA MECHANICAL CODE 2016 CALIFORNIA PLUMBING CODE 2016 CALIFORNIA ENERGY CODE SITE INFORMATION 2016 CALIFORNIA FIRE CODE 2016 CALIFORNIA GREEN CODE STANDARDS AND ALL MK TYPE: MK5F_48 APPLICABLE LOCAL AND STATE LAWS AND REGULATIONS JIB #: 0490 EXISTING BUILDING AREA: ±2,236 S.F. (EXISTING). ADDRESS: BUILDING HEIGHT: 1 STORY, 20'-11" 1 451 S. DE ANZA BLVD TOTAL SITE AREA: ±22,314 S.F. CUPERTINO, CA 95014 EXISTING SEATING: 34 SEATS PROPOSED SEATING: 36 SEATS DRAWN BY: OCCUPANCY: A-2 - RESTAURANT (EXISTING) PROJECT #: JRG17001.0 TYPE OF ONSTRUCTION: V -B NON-SPRINKLERED) SCALE: AS NOTED PARKING REQUIREMENTS: 1 PER 3 SEATS = 12 SPAC S 1 PER EMPLOYEE = 7 SPACES TITLE 1 BIKE RACK PER 2000 S.F. FLOOR SPACE = 2 RACKS EXISTING: 19 TOTAL G SPACES (g PACES, 1 ADA ACCESSIBLE PARKING SPACE) SHEET 4 EXISTING BIKE RACKS PROVIDED. PROPOSED: NO CHAN S HOURS OF OPERATION: 6:30AM-2:OOAM FOR DINING AREA 24 HOUR FOR DRIVE-THRU TS1 mO PLANT SCHEDULE TREESTCTYY BOTANICAL NAME COMMON NAME CONT WUCOLS o (E) EXISTING TREES/SHRUBS TO REMAIN 6 LAGERSTROEMIA X 'CHEROKEE' CRAPE MYRTLE RED 15 GAL LOW 8 RHAMNUS CA 'MOUND SAN BRUNO' CA COFFEEBERRY 5 GAL LOW 130 HELICTOTRICHON SEMPERVIRENS BLUE OAT GRASS 1 GAL LOW 50 DIETES VEGETA AFRICAN IRIS 5 GAL LOW GENERAL NOTES 1. REPAINT PARKING LOT AS NEEDED. 2. MODIFY EXISTING IRRIGATION AS NEEDED FOR NEW PLANTINGS. 3. CITY WILL PROVIDE CONTRACTOR AT NO CHARGE, THREE "NO DUMPING FLOWS TO CREEK"STORM DRAIN INLET MARKERS FOR INSTALLATION. COORDINATE WITH ALEX WYKOFF OR CHERI DONNELLY WHEN READY PRIOR TO FINAL INSPECTION. D (E) LS TO REMAIN (E) CURB TO BE REMOVED (N) CURB — EX& IRRIGATION TO — (N) PLANTER AS NEEDED E) LS TO REMAIN + + + + + + + + + + + +� + + + + + + + ° + + + + + + + + + o + + + + +++++ (N) CANOPY OVER (E) PREVIEW MENU + + + + + + + + (E) LS TO MENU ORDER BOARD. ORDER BOARD REMAIN SEE DET. 2/SD1.1 S - 00 00'00"E 140.00' - - - - - - (E) LS TO REMAIN + O w V) is +p +p o j 00 + -H + (E) CONC. (E) AC = —� ++ ++ (E) PARKING —� PAVEMENT + + - - � Of ! Of Z Q J w a + 1 + + +o + + + + + + + + STORM DRAIN + + + INLET MARKER, _ "NO DUMPING + + + + + ++ + FLOWS TO CREEK + + p+ + + + + + + + c+:_:O�+ ds+ + + + + + + + + + +� + INSTALL (N) "BIO CLEAN 2% + + + + + + + + + + + + ENVIRONMENTAL" GRATE INLET MAX + + + + + + + + + + + + + + + TUBE STEEL POST o+ + + + + + + + + + + + I + + FOR ROOF ABOVE. FILTERS (GISB) ON ALL THREE + + + + + + + + + + + + + (E) TRASH + + (TYP OF 4) (E) SITE STORM DRAIN INLETS. + + + + + + + + + + + + + ENCLOSURE + + + + + + + + + + + + + + +I + + SEE DET. 1 /SD1.1 CONTRACTOR TO VERIFY EXACT I=> + + + + + + + + + + + + + + + + SIZING BEFORE ORDERING TYP + +p ' + + + + + + + + _1 10 �o + + + + + + + + (E) LS TO REMAIN + O w V) + +p + o j 00 + -H + F-1 + + + +p + (E) PARKING + + + + + � � er + + + + +o + + + + + + + + + p + + + + i� (E) CURB TO RIDGE + + + + 4 + + + + + + + + + + + + p - II + + + + + + + + _ + + + + °+ + I I 0 U o+ (E) LS TO + ----- o + REMAIN n + II + + II� + 10 (E) ON C. - (E) AC PAVEMENT �o +/ 0 w V) o j 00 -H F-1 0n the box 5F48/P 21236 SQ. FT. (E) LS TO REMAIN (E) BIKE RACK TO REMAIN n • 7'_0" II (E)f18'-0„ u n I I X00000 X0000 %0 0000 q ,00 .0 0�GO 0 0�� 0 0 00 000 0�0 � �Q = 3 v 3 ----- (N) PUBLIC R/W MAX STORM DRAIN INLET MARKER, MAX0 NO DUMPING FLOWS TO CREEK 0 00 0 EgEl . 4 (N) WASTE TRIO, RECYCLE AWAY (N) STREET MODEL N1, "RECYCLE", "TRASH", & TREE "COMPOST" LABELS, (N) CIGARETTE BUTT URN, INSTALL DOME COVERS ON ALL RECEPTACLES, TYP. ±43'-8" 5'-0" NEW DRIVEWAY PER CITY DETAIL (1-20) SITE PLAN SCALE: 1"= 10' EXISTING PARKING COUNT: 18 STANDARD 01 ACCESSIBLE 19 TOTAL n 18'-0" ul 7__/__7__7 n / U/ 1 —/ —L— q n (N) 3' WIDE 14)II TRUNCATED 10 L1 DOMES 0 0 0 0 Go 00 0 0 (N) 5' WIDE PATH OF TRAVEL TO PUBLIC R.O.W. 19'-0" 10'-0" �5-0'19'-1" S. DE ANZA BLVD. CM EXISTING LANDSCAPE COVERAGE: LOT = 22, 314 S.F. +/- LANDSCAPE = 5,250 S.F +/ 5)250/22)314 = 24% z 0 BE REMOVED R10' 00 0 0 0 0 (N) CURB 00000000600 ----- — _ 0 + •/E+) + +LIS .00 I + + + G - R 5' + + EXTEND IRRIGATION TO II + + + (N) PLANTER AS NEEDED II + 0 0 I f24'-0" II �� • II° rn II °' M + + + (E) STORM WATER II + + FLOW LINES, TYP. II + + + ° e 0 0) (N) VAN ACCESSIBLE PARKING 0 N 01 I in (N) MONUMENT SIGN (N) BLUE OAT GRASS, TYP (N) CUR - II 3 II 0 ++ ?,Otl' � ° + +S+ 18'-0" f4' f12'-5" + + + + + II Z + + II 0 °� + II II � II I I� (N) CURB II M II ° II . II II T � • II II 0 II (D000 II � II STORM DRAIN II INLET MARKER 11 II "NO DUMPING II FLOWS TO CR:E " (E) MONUMENT SIGN TO BE R10' REMOVED 0//00 =90°11'50" // 0 R=20.00' L=31.48' 2SI MAX @ IL (N—�LUBLIC R/W / R1 5' N 00°00'00"E 119.93' -(E) LS AND CURB TO BE REMOVED \0000 0 00 0 30'-0" (E) DRIVEWAY 0 (N) BLUE OAT GRASS, TYP (N) CA COFFEEBERRY, TYP (E) ROSE BUSHES TO REMAIN. TYP >= Q (N) STREET TREE LU O J LimJ — (N) CRAPE MYRTLE TYP OF 6 (N) AFRICAN IRIS, TYP in the box 9330 BALBOA AVENUE SAN DIEGO, CA 92123 © 2007 Jack in the Box Inc. These designs, drawings and specifications are the property of Jack in the Box Inc and shall not be copied or reproduced without its previous written consent. These drawings attached are intended to assist the architect in preparing site -adapt construction documents provided that such use does not conflict with rules governing architects in the state where the work is to be performed. They will need to be modified to comply with all applicable codes and site-specific conditions. DATES RELEASE: AUG. 24, 2015 P.M. UPDATES: SEPT. 22, 2016 SUBMITTAL DATE: 1: 2: 3: BID: CONSTRUCTION: REVISIONS 0 Comments from Planning and Public Works 5/4/11 Comments from Planning and Public Works 1/12/11 0 Comments from Planning and Public Works 8/8/11 Comments from Planning and Public Works 8/16/11 0 SEo A RCy/T 504 1/19 FOS - REN.1/3 9TF OF C p,\_\F DESIGN Architectural Solutions Group 6930 DESTINY DRIVE SUITE 100 ROCKLIN, CA 95677 (916) 415-5358 rpedro@pmdginc.com Roy W. Pedro, Architect SITE INFORMATION MK TYPE: MK5F 48 JIB #: 0490 ADDRESS: 1451 S. DE ANZA BLVD CUPERTINO, CA 95014 DRAWN BY: BL PROJECT #: JRG17001.0 SCALE: AS NOTED SITE PLAN ■ 24 GA. GSM FLASHING. PAINT TO MATCH ROOF COLOR. FLASHING TO WRAP 6 j ROOF PLAN 5 UNDERNEATH METAL STUDS. SD1.1 SD1.1 s SD1.1 12 5 1 SD1.1 OTRASH ENCLOSURE ELEVATION AEP SPAN H-36 20 GA. METAL PANEL ROOFING. COLOR: GREY N I 0 HSS PER PLAN, PRIMED AND PAINTED I L3 X 5 X i" X O' X 9" GALV. W/ (2) GALV. 5/8" DIA SIMPSON WEDGE — ALL @ 6" GAGE W/ 4 1/2" MIN EMBED. INSTALL PER ICC ER -3631 + + TUBE STEEL POST FOR ROOF ABOVE. TYP OF 41+1 L EXISTING TRASH ENCLOSURE OTRASH ENCLOSURE -ENLARGED CMU TRASH ENCLOSURE 3/16 Zt + (N) 6" CURB (N) SLAB A d ° a i ° A ° d 1 1/2" NON 00 SHRINK GROUT _ 1/2"0 AB W/ DBL NUTS, IMBED 12" MIN., TYP 3" CLR (2) #4 EA WAY 1'-8» SQUARE NOTE: FOOTING AT COLUMN LOCATION ONLY. TIE INTO CMU WALL FOOTING. 1/2" = 1'-0" I 4O ROOF POST ATTACHMENT DETAIL AEP SPAN H-36 20 GA. METAL PANEL ROOFING. COL" 24 GA. GSM FLASHINC PAINT TO MATCH ROC COLOR. FLASHING TC WRAP UNDERNEATH M STUDS. H.S.S.. 6x 4x 1/4" BEA H.S.S. 4x 4x 1/4" CO OROOF DETAIL 8"x2.5x18GA Z ^"^"" AT 2' 0. C. 1 /4"x4"x4" A3 (2) 1/2" 0 BC PP TYI 4 1 /2" X 4 1, PLATE 50 KSI H.S.S. 4x 4x 1 1/4" = V-0" 1/2" _ 1'-0" I + ROOF DETAIL AEP SPAN H-36 20 GA. METAL PANEL ROOFING. COLOR: GREY (2) SMS © EA. VALLEY 24 GA. GSM FLASHING TO STOP AT BOTTOM OF METAL STUDS AT BEAM LOCATIONS. PAINT TO MATCH ROOF COLOR. (2) #12 SMS H.S.S.. 6x 4x 1/4" FLASHING TO WRAP UNDER METAL STUDS BETWEEN BEAMS. PREFABRICATED WEATHER CANOPY PROVIDED AND INSTALLED BY SIGN CONTRACTOR NOTE: CONCRETE BASE TO HAVE 1" RADIUS EDGES AND BE SLOPED TO DRAIN. (4)-5/8"0 x 36" EMBED MIN. HEADED ANCHOR RODS (4" PROJ.), FURNISHED AND INSTALLED BY GEN. CONTR.. SEE DETAIL 8 SD1.1 FOR ANCHOR ROD LAYOUT CONIC. CURB CONC. DRIVEWAY LOOP FURNISHED BY T.O.C. OWNER & INSTALLED BY CONTRACTOR • FIN. GRAD SUPPORT #4 TIES @ 4" 0. C. — TOP 32", REMAINDER 0 12" O.C. (12)—#4V — MK9-X-DT035b.DWC424 2O SPEAKER BOARD SECTION BASE COVER CID I in the box M 9330 BALBOA AVENUE SAN DIEGO, CA 92123 © 2007 Jack in the Box Inc. ap These designs, drawings and specifications are the property of Jack in the Box Inc and shall not be copied or reproduced without its previous written consent. These drawings attached are intended to assist the architect in preparing site—odapt construction documents provided that such use does not conflict with rules governing architects in the state where the work is to be performed. They will need to be modified to comply with all applicable codes and site—specific conditions. DATES RELEASE: AUG. 24, 2015 P.M. UPDATES: SEPT. 22, 2016 SUBMITTAL DATE: °' 1 2: 3: BID: CONSTRUCTION: REVISIONS Comments from Planning and Public Works 5/4/11 Comments from Planning and Public Works 1/12/11 �o o� 00 �z }o Q U � U C) w w zN L W Uj a� Q w o � Q w �CL N W 2'-0" MIN FOR ELECTRICAL RUNS REFER TO SHEET E51.0 1/2" = 1'-0" O7 PLATE DETAIL Y U N X w ry a 0 N AT CORNER NOTE: COORDINATE ANCHOR BOLT LAYOUT WITH SIGN CONTRACTOR PRIOR TO INSTALLATION MK9-X-DT028b.DWCI4 BOLTING TEMPLATE AT SPEAKER 1" = 1'-0" O8 AND PREVIEW BOARDS N.T.S. 5"0 STEEL PIPE 3 1/2" DIA. OPENING BASE PLATE FURNISHED AND INSTALLED BY SIGN CONTRACTOR A RC/yi:-� ny W PE�� s\FREN.1/31/19 OCA\O F \_F IFAF DESIGN Architectural Solutions Groijn 6930 DESTINY DRIVE SUITE 100 ROCKLIN, CA 95677 (916) 415-5358 rpedro@pmdginc.conn Roy W. Pedro, Architect SITE INFORMATION MK TYPE: MK5F 48 JIB #: 0490 ADDRESS: 1451 S. DE ANZA BLVD CUPERTINO, CA 95014 DRAWN BY: PROJECT #: JRG17001.0 SCALE: AS NOTED /2" x 5/8" HOLE DETAILS TYPICAL OF 4 A 3" = 1'-0" ■ PHOTO 9 EXISTING LANDSCAPING TO REMAIN. PHOTO 10 EXISTING LANDSCAPING AND DRIVE THRU TO REMAIN. PHOTO 11 EXISTING PLANTERS TO REMAIN. PHOTO 12 EXISTING PLANTERS TO REMAIN. PHOTO 7 EXISTING LANDSCAPING TO REMAIN. PHOTO 8 EXISTING LANDSCAPING TO REMAIN. MT - PHOTO 5 EXISTING LANDSCAPING TO REMAIN. PHOTO 6 EXISTING LANDSCAPING TO REMAIN. I �O 4 EXISTING AERIAL SCALE: N/A Vim/ NORTH PHOTO 1 EXISTING LANDSCAPING TO REMAIN. % PHOTO 2 EXISTING PLANTERS TO REMAIN. PHOTO 3 EXISTING LANDSCAPING TO REMAIN. PHOTO 4 EXISTING LANDSCAPING TO REMAIN. in the box 9330 BALBOA AVENUE SAN DIEGO, CA 92123 © 2007 Jack in the Box Inc. These designs, drawings and specifications are the property of Jack in the Box Inc and shall not be copied or reproduced without its previous written consent. These drawings attached are intended to assist the architect in preparing site—odapt construction documents provided that such use does not conflict with rules governing architects in the state where the work is to be performed. They will need to be modified to comply with all applicable codes and site—specific conditions. DATES RELEASE: AUG. 24, 2015 P.M. UPDATES: SEPT. 22, 2016 SUBMITTAL DATE: 1: 2: 3: BID: CONSTRUCTION: REVISIONS Al Comments from Planning and Public Works 5/4/11 AComments from Planning and Public Works 1/12/11 0 A 0 A ��SED A RC/ / PE�� FCS C-28504 REN. 1/31/19 �TFOF CA\_\FOS pd�w `q� DESIGN Architectural Solutions Group 6930 DESTINY DRIVE SUITE 100 ROCKLIN, CA 95677 (916) 415-5358 rpedro@pmdginc.conn Roy W. Pedro, Architect SITE INFORMATION MK TYPE: MK5F_48 JIB #: 0490 ADDRESS: 1451 S. DE ANZA BLVD CUPERTINO, CA 95014 DRAWN BY: PROJECT #: JRG17001.0 SCALE: AS NOTED PHOTO LANDSCAPE PLAN Ll ■ FLOOR PLAN DEMO KEY NOTES O(E) ENTRY DOOR TO REMAIN. O(E) WINDOWS AND STOREFRONT TO REMAIN. O(E) ELECTRICAL PANEL/ METERS TO REMAIN. O4 (E) ROOF LADDER LOCATION TO REMAIN. O5 (E) WALK—IN COOLER/ FREEZER TO REMAIN. REMOVE AND DISPOSE EXISTING DINING FURNITURE, PARTIAL HEIGHT WALLS, COUNTERS AND OWALL TRIMS, AND TILE FLOORING THROUGHOUT. REMOVED EXISTING WALL FINISHES TO GYP BOARD SHEATHING AND/OR REPLACE GYP BOARD IN OIRREPARABLE AREAS FOR INSTALLATION OF NEW INTERIOR FINISHES. PREPARE SURFACES AND PATCH ANY DAMAGES DUE TO DEMOLITION. REFER TO INTERIOR ELEVATIONS. O8 REMOVE (E) SERVICE COUNTER, SURROUNDING FINISHES, AND EQUIPMENT. PREP FOR (N) WORK. O(E) DOOR AND FRAME TO BE REMOVED. "NON FOOD" WASTE CONTAIN 10 REMOVE (E) DOOR AND FRAME AND PREP FOR (N). 11 REMOVE (E) FRP PANELS AS REQ'D AND PREP FOR NEW. FIELD VERIFY (E) CONDITIONS. 12 REMOVE (E) RESTROOM FIXTURES, WALL & FLOOR FINISHES AND PREP FOR (N) WORK. (E) KITCHEN EQUIPMENT — PROTECT IN PLACE OR REMOVE OR REMOVE EQUIPMENT PRIOR TO 13 CONSTRUCTION 14 (E) DRINK STATION TO REMAIN. PROTECT IN—PLACE OR REMOVE EQUIPMENT. REMOVE (E) WALL PAPER GRPAHICS. EXISTING/ DEMO FLOOR PLAN S C A L E: 3/ 16 "= 1'— 0" FLOOR PLAN KEY NOTES ONEW SERVICE COUNTER. SEE DETAIL 18/ID3.0. O(E) DRINK STATION EQUIPMENT TO BE REINSTALLED AT SAME LOCATION. GC TO PROVIDE PROTECTION AT CONNECTIONS AS REQ'D. OINSTALL NEW GC—WP AT AREAS WHERE DAMAGED AND OR BUCKLING. FIELD VERIFY O4 WALL FURRING, SEE DETAIL 12/1D3.0. OEND CAP ON WALL TO BE FLUSH W/ SOFFIT FINISH ABOVE. SEE INTERIOR DETAILS FOR ADDITIONAL INFORMATION. 6 IN—FILL (E) R LOC TION. MATCH ADJACENT CONSTRUCTION, FINISHES, ETC. 730 GAL "NON FOOD" WASTE CONTAIN 8 30 GAL ^ "FOOD" WASTE CONTAINER. ^ n 1 FLOOR PLAN S C A L E: 3/ 16 "= 1'— 0" GENERAL NOTES 1. ALL HEIGHTS SHOWN ARE FROM TOP OF F.F. 2. DIMENSIONS ARE FROM FINISH FLOOR AND/OR FINISHED DRYWALL. 3. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL QUANTITIES BEFORE ORDERING AND INSTALLING MATERIAL. 4. GC TO COORDINATE WITH CM/OWNER FOR ALL EQUIPMENT TO REMAIN AND BE RE—USED. GC TO ENSURE SECURE STORAGE DURING INTERIOR WORK PRIOR TO RE—INSTALLATION. 5. GC IS RESPONSIBLE FOR VERIFICATION OF EXISTING CONDITIONS PRIOR TO BID/CONSTRUCTIION. IT IS THE RESPONSIBILITY OF THE GC TO NOTIFY THE ARCHITECT AND/OR CM OF FIELD CONDITIONS CONFLICTING WITH CONSTRUCTION DOCUMENTS PRIOR TO NEW WORK BEING PERFORMED. 6. PROVIDE 2x SOLID BLOCKING IN WALLS AS REQUIRED FOR REINFORCEMENT OF ALL GRAB BARS, RESTROOM FIXTURES, PLUMBING LINES, WALL BUMPERS AND MILLWORK ATTACHMENT, ETC. 7. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT ANY SPECIAL KNOWLEDGE OR EFFORT OR THE USE OF A KEY. 8. ALL EXTERIOR DOORS SHALL BE WEATHER—STRIPPED. ALL EXTERIOR JOINTS AROUND DOOR FRAMES & WINDOWS & AT ALL PENETRATIONS THROUGH BUILDING ENVELOPE SHALL BE SEALED USING SEALANT & CAULKING. ADDITIONALLY, FOAM INSULATION SHALL BE PROVIDED IN & AROUND ALL WINDOW AND/OR DOOR FRAMES WHERE METAL MEETS WOOD FRAMING PLUS ALL EXTERIOR WALL OPENINGS/PENETRATIONS. 9. ALL GLAZING WITHIN 48" OF DOORS & 18" FROM FINISHED FLOOR SHALL BE TEMPERED INCLUDING GLAZING OF DOORS. 10. POST OCCUPANCY LOAD SIGN IN CONSPICUOUS PLACE NEAR MAIN EXITS AT 6'-10" A.F.F. CAULK AROUND ALL SIDES. "MAXIMUM SEATING CAPACITY — 45". FOR SEAT COUNT, SEE "BUILDING DATA" ON COVER SHEET. 11. ALL NEW FINISH SURFACES SHALL HAVE A FLAME SPREAD CLASSIFICATION OF CLASS C OR HIGHER (FLAME SPREAD INDEX 76 THROUGH 200 & A SMOKE DENSITY RATING OF 450). 12. ALL DRAPES, CURTAINS & DECORATIVE MATERIAL PROVIDED AND/OR INSTALLED BY THE GENERAL CONTRACTOR SHALL BE MADE FROM NONFLAMMABLE MATERIALS OR TREATED WITH FLAME RETARDANT AS APPROVED BY THE LOCAL FIRE MARSHAL. 13. OWNER SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS PER LOCAL FIRE MARSHAL. 14. GENERAL CONTRACTOR TO INSTALL. BUILDING ADDRESS NUMBERS SHALL BE A MINIMUM 12" HIGH AND BE OF CONTRASTING COLORS. 15. ANY TIME THE BUILDING IS OCCUPIED, THE MEANS OF EGRESS SHALL BE ILLUMINATED AT AN INTENSITY OF NOT LESS THAN 1 FOOT—CANDLE AT THE FLOOR LEVEL. SEE ELECTRICAL DRAWINGS. 16. PROVIDE APPROVED EGRESS ILLUMINATION AND ILLUMINATED EXIT SIGNS. SEE ELECTRICAL DRAWINGS. 17. PROVIDE APPROVED PANIC HARDWARE ON EXIT DOORS. 18. EXIT AISLES SHALL MEET ALL APPLICABLE CODES. 19. GC TO VERIFY WITH CM/OWNER ALL RESTROOM EQUIPMENT TO REMAIN AND BE RE—USED PENDING CONDITION. NORTH Z [ III I in the box 9330 BALBOA AVENUE SAN DIEGO, CA 92123 © 2007 Jack in the Box Inc. These designs, drawings and specifications are the property of Jack in the Box Inc and shall not be copied or reproduced without its previous written consent. These drawings attached are intended to assist the architect in preparing site—odapt construction documents provided that such use does not conflict with rules governing architects in the state where the work is to be performed. They will need to be modified to comply with all applicable codes and site—specific conditions. DATES RELEASE: AUG. 24, 2015 P.M. UPDATES: SEPT. 22, 2016 SUBMITTAL DATE: 1: 2: 3: BID: CONSTRUCTION: REVISIONS Al Comments from Planning and Public Works 5/4/11 AComments from Planning and Public Works 1/12/11 0 0 A ED A RC/ / PE�� FCS - 504 REN. 1/31/19 �TFOF CA\_\FOS IFAF DESIGN Architectural Solutions Groijn 6930 DESTINY DRIVE SUITE 100 ROCKLIN, CA 95677 (916) 415-5358 rpedro@pmdginc.conn Roy W. Pedro, Architect SITE INFORMATION MK TYPE: MK5F 48 JIB #: 0490 ADDRESS: 1451 S. DE ANZA BLVD CUPERTINO, CA 95014 DRAWN BY: PROJECT #: JRG17001.0 SCALE: AS NOTED DEMO/PROPOSED FLOOR PLAN Al ■ ROOF PLAN DEMO KEY NOTES D1 EXISTING MANSARD STEEL FRAMING TO BE REMOVED IN ITS ENTIRETY AS SHOWN. REMOVE EXISTING ROOFING OVER STRUCTURE IN ITS ENTIRETY. D2 GC TO VERIFY CONDITION OF PLYWOOD DECKING AND REPLACE WHERE DAMAGED, TYP. D3 EXISTING ROOF ACCESS HATCH LOCATION TO REMAIN. D4 18" SECTION OF CANOPY OVERHANG TO BE REMOVED. SEE SHEETS A6.0 FOR DETAILS EXISTING ROOF CONDENSORS, RTU'S, AND ROOF EQUIPMENT IN D5 SERVICE TO BE REMOVED AND SECURED IN STORAGE FOR RE—INSTALLATION AFTER NEW ROOF WORK IS COMPLETED. ROOF TOP EQUIPMENT CURBS TO BE REMOVED AND REPLACED D6 WITH NEW. MAINTAIN 8" MIN ABOVE TAPERED INSULATION AT ALL LOCATIONS. TYP. D4 r�=—�--�—�--�--�—�--�----�--�--—�--�----�--�—�--�--�—�--�----�--�----�� II I II I I II I I I I II I I II II --------------- —---------------- —---------------- I I I I II I I I I I I I II I I I I I I I I I II I II I I I I I I I I I I I II II I II I II I IL — — — — -- JI I I I II II I I I I I I • I I � I� I I I I I [:-f=--=P I I II I I I I 1 F-7 F-1 IT- — — r— — J • I i l II I II I L__J I I I II I II I D3 I I I II I I I I I I I II II I I I I I I II II I I I I I I I II �I I I I I II I I I TYP. O I I I II I I I I I I I II II I I I I D2 I I I II I I I I I I D5 TYP. • I I TYP. TYP. I I D6 TYP. I I D4 I 04 II I II II I L. J %/I I 11%/ J I I I I I II �I I II 1 1 i l I I II IL----}> L ----J I I I II I I I I I F` —9 III I I I I I I I I I I I I I II III � I I I I I I I I I I I II III I 1 � I I I I I I I I D5 I I I II I I I I I I I I I I II I I III II I I I I I I I F— --F---T---- �_::il I I ��---T---- �_� I I I II I I I I I I L� I I \_� I I I I I I I I L� I I \_� I III I I I I I I I I L S I I II I I L S I 7 I I II I I I II I I L---1---- =J I I L---L------- L _ L_J I I II II I I I I I I I II 11 I I I I I I I II II I I I I I I I II I I I I TYP. D1 I I I 11 I I I I I II I� I �L----------------- I I II --- -------------------------- 11 I I II I I TYP. I I I I 11 I D4 I I I 11 L---------------------------- -i II LL— ---------------------------------------------------------------- EXISTING/ DEMO ROOF PLAN S C A L E: 3/ 16 "= 1'— 0" TYP. ROOF KEY NOTES 0 O O O O O O O O 10 NEW MEMBRANE ROOFING OVER CONTINUOUS ROOF DECK TAPERED INSULATION. 50 MIL DUROLAST 15 YEAR NOL ROOF LABOR & MATERIAL PER JIB. NEW PARAPET BRACE. NOT USED EXISTING ROOF TOP EQUIPMENT TO BE PLACED ON NEW CURBS REINSTALL RAISED PARAPET WALLS, PATCH AS REQUIRED. (E) LED WALL WASHER LIGHTS, SEE ELECTRICAL DRAWINGS. EXISTING ROOF HATCH ACCESS HATCH. ENSURE HEIGHT ABOVE TAPERED INSULATION TO AVOID WATER INFILTRATION. REINSTALL JIB WALL SIGNAGE, SEE EXTERIOR ELEVATIONS. LINE OF WALK—COOLER WALLS BELOW. (N) PERIMETER METAL FASCIA AND GUTTER. 17A r �I F 5 I ' " (E) EF 4 TYP III I I I 0 III II I II II 17A I o III IIO II NM I II II III II (ACR2 II III II 11 II z z II LJ J� TYP. (E) EF 1 z TYP. SLOPE 3/8"/FT. E(E) RTU z AC 1 PROPOSED ROOF PLAN 17A — TYP. —� I (E) COND. I I (E) COND. 0 0 C E COND. 0 I SLOPE 3/8"/FT. (R F 3 UZ 1 (E) EF 3 4 I �I TYP. S C A L E: 3/ 16 "= 1'— 0" GENERAL NOTES 1. FOR ROOF FRAMING AND PLYWOOD LAYOUT INFORMATION, SEE STRUCTURAL DRAWINGS. 2. (E) ROOF TOP MECHANICAL EQUIPMENT TO BE RE—INSTALLED PER PREVIOUS LOCATIONS. 3. CURBS AND BASES FOR HVAC UNITS AND EXHAUST FANS SHALL BE INSTALLED LEVEL BY G.C. HVAC UNITS AND EXHAUST FANS SHALL BE HOISTED, SET IN PLACE, AND SECURED TO ROOF CURBS OR BASES BY G.C. AND PER MANUFACTURER'S INSTRUCTIONS. 4. WALK IN BOX ROOF TOP UNIT SHALL BY HOISTED, SET IN PLACE AND SECURED TO ROOF CURB BY G.C. ROOF CURB AND EQUIPMENT PLATFORM BY G.C. 5. ICE MACHINE ROOF TOP UNITS SHALL BE HOISTED, SET IN PLACE AND SECURED TO ROOF CURB BY ICE MACHINE INSTALLER. ROOF CURB AND EQUIPMENT PLATFORM BY G.C. 6. REFER TO STRUCTURAL DRAWINGS FOR MORE INFO. NORTH Z [1111 1 in the box 9330 BALBOA AVENUE SAN DIEGO, CA 92123 © 2007 Jack in the Box Inc. These designs, drawings and specifications are the property of Jack in the Box Inc and shall not be copied or reproduced without its previous written consent. These drawings attached are intended to assist the architect in preparing site—odapt construction documents provided that such use does not conflict with rules governing architects in the state where the work is to be performed. They will need to be modified to comply with all applicable codes and site—specific conditions. DATES RELEASE: AUG. 24, 2015 P.M. UPDATES: SEPT. 22, 2016 SUBMITTAL DATE: 1: 2: 3: BID: CONSTRUCTION: REVISIONS Al Comments from Planning and Public Works 5/4/11 AComments from Planning and Public Works 1/12/11 0 A 0 A D A R Cy/T PE� FO - 504 REN. 1/31/19 �TFOF CP,0F0 FFAF DESIGN Architectural Solutions Groijn 6930 DESTINY DRIVE SUITE 100 ROCKLIN, CA 95677 (916) 415-5358 rpedro@pmdginc.conn Roy W. Pedro, Architect SITE INFORMATION MK TYPE: MK5F-48 JIB #: 0490 ADDRESS: 1451 S. DE ANZA BLVD CUPERTINO, CA 95014 DRAWN BY: PROJECT #: JRG17001.0 SCALE: AS NOTED DEMO/PROPOSED ROOF PLAN A3mO ±12' 0" MIFT.O. CANOPY 3 — — — — — — — —— -------------------------- I--------- --------- L ----- I F-1 — -----� 01 '11M DEMO KEY NOTES OREMOVE EXISTING MANSARD STRUCTURE IN IT'S ENTIRETY. GC TO COORDINATE REMOVAL OF EXISTING O2 CANOPY SHORING DURING/AFTER REINFORCEMENT OF EXISTING STRUCTURE, REFER TO STRUCT. O3 REMOVE EXISTING SIGNAGE. OREMOVE 18" OF CANOPY FRAMING AND PREPARE FOR NEW FINISHES. N9 0 0'-0" T.O.S. TYP. TYP. Tw. 01 01 01 19 14 01 06 14 01 10 B N N — TE B — E B — EQ. 7'-7" EQ. �+20 _11" P. — — — TEQ. EQ. o1451 JL — ±20'-11" T.O.P. >E EXISTING FRONT ELEVATION - WEST NEW FRONT ELEVATION - WEST S C A L E : 3/16"= 1'-0" t18 =0"— P. f12'-0= MIFCANOPY 0'-0" O.S. REffffffm H. MMEN EXISTING LEFT ELEVATION - NORTH S C A L E : 3/16"= 1'-0" O.P. +14'-4' �® REVEAL +112" MIFMIFT.O.'—CANOPY _V -o" TYP. NEW LEFT ELEVATION - NORTH S C A L E: 3/16"= 1'-0" EXTERIOR FINISH SCHEDULE ° T.O. S. USE CHECKED BOX ONLY o1 MATERIAL/FINISH ANTI -GRAFFITI COATING: DUMOND CPU647 GRAFFITI BARRIER A COLOR COAT BY DUMOND CHEMICALS INC. (212) 869-6350 COLOR: CLEAR MATERIAL/FINISH: 01 EXTERIOR CEMENT PLASTER- SAND FLOAT FINISH (SEE SPECIFICATIONS) F-1 INTEGRAL COLOR SHERWIN WILLIAMS SHERLASTIC 100% ACRYLIC ELASTOMERIC COATING EXTERIOR INSULATION FINISHING SYSTEM (EIFS) AS ALTERNATE, CONTRACTOR TO SUBSTITUTE EIFS IN LIEU OF EXTERIOR CEMENT PLASTER 02 AWNING/CANOPY & SUPPORT (BY SIGN CONTRACTOR) 03 NOT USED 04 (E) ALUMINUM STOREFRONT SYSTEM 1" CLEAR INSULATED GLASS 1" CLEAR INSULATED GLASS W/ SOLARBAN 70XL COATING ❑1" CLEAR INSULATED GLASS � ANTI -GRAFFITI FILM W/ SOLARBAN 60 COATING 05 NOT USED 06 INTERNALLY ILLUMINATED SIGNAGE (O.F.0.1., NOT A PART OF THIS PERMIT) 07 NEW PRE -FINISHED METAL FASCIA 08 NEW WALL WASH FLOOD LIGHT, REF ELECTRICAL 09 NOT USED 10 12" HIGH BUILDING ADDRESS LETTERS (AS REQUIRED PER LOCAL JURISDICTION) 11 MAIN ELECTRICAL SERVICE 12 NOT USED 13 HOLLOW METAL DOORS AND FRAMES, MISCELLANEOUS TRIM 14 ALUMINUM COPING 15 CO2 FILL BOX METAL COVER 16 (E) BRICK VENEER SLUMPSTONE 17 NOT USED 18 MOUNT LIGHT FIXTURE WITHIN CANOPY 19 WALL MOUNTED LIGHT FIXTURE 20 NOT USED 21 DISPLAY POSTER PANEL AND SURROUND OF-EQ18 OF-EQ19 22 NOT USED 23 ENTRANCE DISPLAY HOURS PANEL <----OF-EQ22 24 DRIVE-THRU WINDOW TREATMENT AND DISPL ANEL 25 FEATURE WINDOW POP OUT W/ ALUMINUM BREAK METAL PANELS & ILLUMINATED LIGHT BOX COLOR: A SHERWIN WILLIAMS: SW 7015 "REPOSE GRAY" B SHERWIN WILLIAMS: SW 6321 "RED BAY" C STANDARD STOREFRONT: CLEAR ANODIZED D WHITE TEXT ON RED BACKGROUND E CLEAR ANODIZED F COLOR/FINISH TO MATCH ADJACENT SURFACE G SHERWIN WILLIAMS: SW 6990 "CAVIAR" H POWDERCOATED ANODIZED SILVER J MAFIC, AV294 K SHERWIN WILLIAMS: SW 7020 "BLACK FOX" L NATURAL CONCRETE, GRAY M STAINLESS STEEL N SHERWIN WILLIAMS: SW 7018 "DOVETAIL" 0 NOT USED P PAINT TO MATCH CLEAR ANODIZED ALUMINUM, TIGER DRYLAC 38/91020 R PRE -FINISHED "DARK BRONZE". GENERAL NOTES: 1. ALL SIGNAGE IS UNDER SEPARATE SUBMITTAL AND PERMIT (N.I.C.). 2. C.J. = PLASTER CONTROL JOINT 3. ALL PLASTER ACCESSORIES, FLASHINGS ETC. SHALL BE PAINTED TO MATCH ADJACENT SURFACES. (U.0.N.). 4. ALL EXTERIOR WALL OPENINGS FOR RECEPTACLES, HOSE BIBBS, ETC. SHALL BE SEALED. SEE FLOOR PLAN, GENERAL NOTES, AND SPECIFICATIONS FOR ADDITIONAL NOTES. in the box 9330 BALBOA AVENUE SAN DIEGO, CA 92123 © 2007 Jack in the Box Inc. These designs, drawings and specifications are the property of Jack in the Box Inc and shall not be copied or reproduced without its previous written consent. These drawings attached are intended to assist the architect in preparing site—odapt construction documents provided that such use does not conflict with rules governing architects in the state where the work is to be performed. They will need to be modified to comply with all applicable codes and site—specific conditions. DATES RELEASE: AUG. 24, 2015 P.M. UPDATES: SEPT. 22, 2016 SUBMITTAL DATE: 1: 2: 3: BID: CONSTRUCTION: REVISIONS Al Comments from Planning and Public Works 5/4/11 AComments from Planning and Public Works 1/12/11 0 L 0 D A RC/,/ PE�� FCS - 504 REN.I/31/19 �TFOF CP,0F0 FFAP DESIGN Architectural Solutions Groijn 6930 DESTINY DRIVE SUITE 100 ROCKLIN, CA 95677 (916) 415-5358 rpedro@pmdginc.com Roy W. Pedro, Architect SITE INFORMATION MK TYPE: MK5F 48 JIB #: 0490 ADDRESS: 1451 S. DE ANZA BLVD CUPERTINO, CA 95014 DRAWN BY: PROJECT #: JRG17001.0 SCALE: AS NOTED EXTERIOR ELEVATIONS A4mO f18-0 _ P t12'-0" VIF CANOPY o' -o" T.O.S. DEMO KEY NOTES OREMOVE EXISTING MANSARD STRUCTURE IN IT'S ENTIRETY. GC TO COORDINATE REMOVAL OF EXISTING O2 CANOPY SHORING DURING/AFTER REINFORCEMENT OF EXISTING STRUCTURE, REFER TO STRUCT. O3 REMOVE EXISTING SIGNAGE. OREMOVE 18" OF CANOPY FRAMING AND PREPARE FOR NEW FINISHES. F---------------------------------------------------------------`�� I I +20 -11 "_ P. -(BEYOND +19 -4 _ P. FIXTURE +14 -4 EVEAL +11'-2" VIF CANOPY 0'-0" T.O.S. EXISTING REAR ELEVATION - EAST NEW REAR ELEVATION - EAST S C A L E : 3/16°'= 1'-0" t18 -o P. - t12'-0" VIF CANOPY -------------- ------------ ------------ r � _--� _— = r--'--------------------------------------------------------------------------------------- —� I I i EXISTING RIGHT ELEVATION - SOUTH S C A L E : 3/16"= 1'-0" 20'. O.P-11 YT. �+�11'-2" \11FYT.0 CANOPY o' -o" O.S. TW n?. rm. n?. NEW RIGHT ELEVATION - SOUTH S C A L E : 3/16"= 1'-0" EXTERIOR FINISH SCHEDULE USE CHECKED BOX ONLY of MATERIAL/FINISH ANTI -GRAFFITI COATING: DUMOND CPU647 GRAFFITI BARRIER A COLOR COAT BY DUMOND CHEMICALS INC. (212) 869-6350 COLOR: CLEAR MATERIAL/FINISH: 01 EXTERIOR CEMENT PLASTER- SAND FLOAT FINISH (SEE SPECIFICATIONS) F-1 INTEGRAL COLOR SHERWIN WILLIAMS SHERLASTIC 100% ACRYLIC ELASTOMERIC COATING EXTERIOR INSULATION FINISHING SYSTEM (EIFS) AS ALTERNATE, CONTRACTOR TO SUBSTITUTE EIFS IN LIEU OF EXTERIOR CEMENT PLASTER 02 AWNING/CANOPY & SUPPORT (BY SIGN CONTRACTOR) 03 NOT USED 04 (E) ALUMINUM STOREFRONT SYSTEM 1" CLEAR INSULATED GLASS 1" CLEAR INSULATED GLASS W/ SOLARBAN 70XL COATING ❑1" CLEAR INSULATED GLASS F-1 ANTI -GRAFFITI FILM W/ SOLARBAN 60 COATING 05 NOT USED 06 INTERNALLY ILLUMINATED SIGNAGE (O.F.0.1., NOT A PART OF THIS PERMIT) 07 NEW PRE -FINISHED METAL FASCIA 08 NEW WALL WASH FLOOD LIGHT, REF ELECTRICAL 09 NOT USED 10 12" HIGH BUILDING ADDRESS LETTERS (AS REQUIRED PER LOCAL JURISDICTION) 11 MAIN ELECTRICAL SERVICE 12 NOT USED 13 HOLLOW METAL DOORS AND FRAMES, MISCELLANEOUS TRIM 14 ALUMINUM COPING 15 CO2 FILL BOX METAL COVER 16 (E) BRICK VENEER SLUMPSTONE 17 NOT USED 18 MOUNT LIGHT FIXTURE WITHIN CANOPY 19 WALL MOUNTED LIGHT FIXTURE 20 NOT USED 21 DISPLAY POSTER PANEL AND SURROUND OF-EQ18 OF-EQ19 22 NOT USED 23 ENTRANCE DISPLAY HOURS PANEL <----OF-EQ22 24 DRIVE-THRU WINDOW TREATMENT AND DISPL ANEL 25 FEATURE WINDOW POP OUT W/ ALUMINUM BREAK METAL PANELS & ILLUMINATED LIGHT BOX COLOR: A SHERWIN WILLIAMS: SW 7015 "REPOSE GRAY" B SHERWIN WILLIAMS: SW 6321 "RED BAY" C STANDARD STOREFRONT: CLEAR ANODIZED D WHITE TEXT ON RED BACKGROUND E CLEAR ANODIZED F COLOR/FINISH TO MATCH ADJACENT SURFACE G SHERWIN WILLIAMS: SW 6990 "CAVIAR" H POWDERCOATED ANODIZED SILVER J MAFIC, AV294 K SHERWIN WILLIAMS: SW 7020 "BLACK FOX" L NATURAL CONCRETE, GRAY M STAINLESS STEEL N SHERWIN WILLIAMS: SW 7018 "DOVETAIL" 0 NOT USED P PAINT TO MATCH CLEAR ANODIZED ALUMINUM, TIGER DRYLAC 38/91020 R PRE -FINISHED "DARK BRONZE". GENERAL NOTES: 1. ALL SIGNAGE IS UNDER SEPARATE SUBMITTAL AND PERMIT (N.I.C.). 2. C.J. = PLASTER CONTROL JOINT 3. ALL PLASTER ACCESSORIES, FLASHINGS ETC. SHALL BE PAINTED TO MATCH ADJACENT SURFACES. (U.0.N.). 4. ALL EXTERIOR WALL OPENINGS FOR RECEPTACLES, HOSE BIBBS, ETC. SHALL BE SEALED. SEE FLOOR PLAN, GENERAL NOTES, AND SPECIFICATIONS FOR ADDITIONAL NOTES. [ III I in the box 9330 BALBOA AVENUE SAN DIEGO, CA 92123 © 2007 Jack in the Box Inc. These designs, drawings and specifications are the property of Jack in the Box Inc and shall not be copied or reproduced without its previous written consent. These drawings attached are intended to assist the architect in preparing site—odapt construction documents provided that such use does not conflict with rules governing architects in the state where the work is to be performed. They will need to be modified to comply with all applicable codes and site—specific conditions. DATES RELEASE: AUG. 24, 2015 P.M. UPDATES: SEPT. 22, 2016 SUBMITTAL DATE: 1: 2: 3: BID: CONSTRUCTION: REVISIONS Al Comments from Planning and Public Works 5/4/11 AComments from Planning and Public Works 1/12/11 0 L 0 ��SED A R Cy/T PE�� FOS - 504 REN. 1/31/19 �TFOF CP, OF FF DESIGN Architectural Solutions Groijn 6930 DESTINY DRIVE SUITE 100 ROCKLIN, CA 95677 (916) 415-5358 rpedro@pmdginc.com Roy W. Pedro, Architect SITE INFORMATION MK TYPE: MK5F 48 JIB #: 0490 ADDRESS: 1451 S. DE ANZA BLVD CUPERTINO, CA 95014 DRAWN BY: PROJECT #: JRG17001.0 SCALE: AS NOTED EXTERIOR ELEVATIONS A4m 1