HomeMy WebLinkAboutAH Summary 01-11-2018CUPERTINO
To:
From:
Date:
Subj:
1.
OFFICE OF COMMUNITY DEVELOPMENT
CITY HALL
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408)777-3308 • FAX (408) 777-3333 r planninga-cupertino.org
,t
Mayor and City Council Members
Planning Commissioners
Benjamin Fu, Assist. Director of Community Development
January 17, 2018
REPORT OF ADMINISTRATIVE HEARING DECISION MADE
January 11, 2018
Chapter 19.12.170 of the Cupertino Municipal code provides for
Appeal of decisions made at an Administrative Hearing
Application
INT -2017-01, Nallely Garcia (Vasavakul residence), 1258 S Stelling Rd
Description
Front Yard Interpretation to designate the property line along S. Stelling Road as the front lot line
and to permit a 1,551 square foot addition to the existing single -story, single-family residence.
Action
The application was approved at the Administrative Hearing. The approval is effective January
11, 2018. The fourteen -calendar day appeal will expire on January 25, 2018.
Enclosures:
Administrative Hearing Report of January 11, 2018
Resolution No(s) 86
Plan set
SUBJECT
COMMUNITY DEVELOPMENT DEPARTMENT
PLANNING DIVISION
CITY HALL
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3308 • FAX (408) 777-3333
ADMINISTRATIVE HEARING STAFF REPORT
Agenda Date: January 11, 2018
Front Yard Interpretation to designate the property line along S. Stelling Road as the front
lot line and to permit a 1,551 square foot addition to an existing single -story, single-family
residence located at 1258 S. Stelling Road. (Application: INT -2017-01; Applicant: Nallely
Garcia, GP Residential Designs; Project Location: 1258 S. Stelling Road; A.P.N.: 366-11-
109)
RECOMMENDED ACTION
That the Hearing Officer adopt the Draft Resolution (Attachment 1) to:
1. Find that the proposed actions are exempt from CEQA; and
2. Approve the Front Yard Interpretation (INT -2017-01) application.
DISCUSSION
Project Data:
Special Area/Neighborhood
South Monta Vista Neighborhood
General Plan Designation
Low Density Residential (1-5 DU/Acre)
Zoning Designation
R1-6 (Single -Family Residential)
Allowed/Required I
Existing
Proposed
Lot Size
9,276 sq. ft. (0.21 acres)
Lot Coverage
50%
22%
39%
Proposed Size
4,174 sq. ft.
1,666 sq. ft.
3,614 sq. ft.
F.A.R.
45%
18%
39%
1st Floor Setbacks
Front
20'
25'-5"
21'-1"
Rear
20'
15'-5"
25'-8"
Street Side
12'
22'-10"
17-1"
Interior Side
5'
25'-8"
11'-0"
Total Building Height
28'
13'-7"
20'
INT -2017-01 1258 S. Stelling Rd. January 11, 2018
Project Consistency With:
General Plan
Yes
Zoning
Yes (upon approval of the Front Yard Interpretation)
Environmental Review.
Categorically Exempt per Section 15301 of the
California Environmental Quality Act (CEQA)
Background:
Proposed Project:
The applicant, Nallely Garcia (GP Residential Designs), representing the property owners
Thaveesinn and Thitiporn Vasavakul is proposing a 1,551 square foot addition to an
existing single -story, single-family residence. As part of the project proposal, the
applicant is requesting a Front Yard Interpretation to establish S. Stelling Road as the
front lot line.
Site Description:
The property is located
at the northwest
corner of S. Stelling
Road and Rainbow
Drive in the Monta
Vista South
neighborhood (Figure
1). The existing 1,666
square foot single -
story home is located
in a residential zoning
district and is
surrounded on all
sides by single-family
residences.
Figure 1: Aerial
The lot was created as a result of a subdivision developed in 1961 in the City of San Jose.
The recorded tract map indicates a 20 -foot building setback line along the S. Stelling Road
frontage for the lot and a 12.5 -foot building setback line along the Rainbow Drive
frontage. Subsequently, the property was annexed to the City of Cupertino in 1982. As a
result of annexation, the property became subject to Cupertino's Municipal Code.
Chapter 19.08 of the Municipal Code defines the front lot line on a corner lot as the shorter
lot line abutting a street. For the subject property, the lot line on Rainbow Drive measures
INT -2017-01 1258 S. Stelling Rd.. January 11, 2018
76.98 feet and the lot line on S. Stelling Road measures 84.31 feet. Therefore, in accordance
with the City's Municipal Code, Rainbow Drive is considered the front lot line.
While the proposed addition is consistent with original subdivision, it is not consistent
with the City's current Zoning ordinance. However, the Municipal Code recognizes that
in certain cases, the definition of the front lot line may be modified, particularly when it
improves the design relationship of the proposed buildings/additions to adjacent
buildings and development, upon review and approval by the City. Therefore, the
applicant has applied for a front yard interpretation.
Analysis:
The proposed project is consistent with the General Plan. It is also consistent with the
Single -Family Residential (R1) Ordinance of the Cupertino Municipal Code in all
respects, should a Front Yard Interpretation be approved.
Setback requirements are intended to establish a consistent pattern of development and
to improve the interface between the street and building frontage. The existing lot pattern
in the neighborhood has the lot on the corner of Rainbow Drive and Aster Lane fronting
Aster Lane and not Rainbow Drive. While both S. Stelling Road and Rainbow Drive are
90 -foot wide streets, S. Stelling has a more residential appearance. Furthermore,
designating the property line along S. Stelling Road as the front lot line would eliminate
the non -conforming status of the existing rear yard setback per the Cupertino Municipal
Code. Currently, under the Municipal Code, the
/ N
existing rear setback for the property is 15'-5" where
a 20' minimum is required. '
A Front Yard Interpretation to designate the
property line along S. Stelling Road as the front lot
line does the following:
1. Reinforce the residential building relationship as
established by the original development of this
subdivision in San Jose;
2. Eliminate the non -conforming status of the
existing residence due to the existing rear yard
setback encroachment per Cupertino regulations;
3. Maintain the frontage orientation of the
surrounding properties (Figure 2); and
4. Improve the relationship of existing residences
and future developments.
Figure 2: Neighborhood pattern
INT -2017-01 1258 S. Stelling Rd. January 11, 2018
Environmental Review
This project is categorically exempt from the requirements of the California
Environmental Quality Act (CEQA) per Section 15301 — Existing Facilities because the
exemption applies to the existing single-family residence.
PUBLIC NOTICING AND COMMUNITY OUTREACH
to
site (one week prior to
No public comments were received at the time of production of this staff report.
PERMIT STREAMLINING ACT
This matter is adjudicatory and is subject to the Permit Streamlining Act (Government
Code Section 65920 — 65964). The City has complied with the deadlines found in the
Permit Streamlining Act.
Project Received: November 22, 2017; Deemed Incomplete: November 29, 2017
Project Resubmitted: December 5, 2017; Deemed Incomplete: December 7, 2017
Project Resubmitted: December 7, 2017; Deemed Complete: December 19, 2017
The City has 60 days (until February 17, 2018) to make a decision on the project.
CONCLUSION
Staff recommends approval . of the Front Yard Interpretation since it will improve the
design relationship of the proposed residential addition to adjacent residences.
Additionally, all of the findings for approval of the proposed project, consistent with the
Cupertino Municipal Code, may be made as reflected in the Draft Resolutions. .
NEXT STEPS
The permit will be effective 14 calendar 1days from the date of the hearing. The decision
of the Administrative Hearing Officer is final, unless appealed within 14 calendar days
from the date of the hearing. The applicant may apply for building and/or other permits
with the City at the end of the appeal period. This approval is valid until January 11, 2019.
The applicant may apply for a one-time one year extension before the approval expires.
INT -2017-01 1258 S. Stelling Rd. January 11, 2018
Prepared b -3L.
Reviewed and Approved by:
ATTACHMENTS
1. Draft Resolution
2. Plan Set
Erika Poveda, Assistant Planner
Piu Ghosh, Principal Planner
INT -2017-01
CITY OF CUPERTINO
10300 Torre Avenue
Cupertino, California 95014
RESOLUTION NO. 86
OF THE ADMINISTRATIVE HEARING OFFICER
OF THE CITY OF CUPERTINO TO ALLOW A FRONT YARD INTERPRETATION
TO DESIGNATE THE PROPERTY LINE ALONG S. STELLING ROAD AS THE
FRONT LOT LINE AND TO PERMIT A 1,551 SQUARE FOOT ADDITION TO THE
EXISTING SINGLE -STORY, SINGLE-FAMILYRESIDENCE LOCATED AT 1258 S.
STELLING ROAD (A.P.N 366-11-109).
SECTION I: PROTECT DESCRIPTION
Application No.: INT -2017-01
Applicant: Nallely Garcia (GP Residential Designs)
Location: 1258 S. Stelling Road (A.P.N. 366-11-109)
SECTION II: FINDINGS
WHEREAS, the City of Cupertino received an application for a Front Yard Interpretation
to designate the property line along S. Stelling Road as the front lot line and to permit a
1,551 square foot addition to the existing single -story, single-family residence; and
WHEREAS, the project is categorically exempt from the California Environmental
Quality Act (CEQA);
WHEREAS, the necessary public notices have been given as required by the Procedural
Ordinance of the City of Cupertino, and the Administrative Hearing Officer has held at
least one public meeting in regard to the application; and
WHEREAS, the applicant has met the burden of proof required to support said
application; and
WHEREAS, the Administrative Hearing Officer finds that:
1. The project is consistent with the Cupertino General Plan, any applicable specific
plans, zoning ordinance, and the purposes of the R1 Ordinance; and
The proposed project is consistent with the existing residential land use designations
surrounding the site and is consistent with Title 19, Zoning, and Chapter 19.28, Single -Family
Residential (R1) Ordinance, of the Cupertino Municipal Code for setbacks, lot coverage, floor
area ratio, and other development standards.
Resolution No. 86 INT -2017-01 January 11, 2018
Page 2
2. The proposed project is harmonious in scale and design with the general
neighborhood; and
The interpretation will reinforce the existing residential building relationship as established
by the original development when the property was. in the City of San Jose, eliminate the non-
conforming status of the existing residence under the Cupertino Municipal Code, maintain
the frontage orientation of the subject site and surrounding properties, and improve the
relationship of existing residences and future developments.
3. The granting of the permit will not result in a condition that is detrimental or injurious
to property or improvements in the vicinity, and will not be detrimental to the public
health, safety, or welfare.
No changes to site access are proposed. The driveway continues to be located farthest from the
intersection of S. Stelling Road and Rainbow Drive. The property is graded to be level to
Stelling Road but is higher than Rainbow Drive. Therefore, there is no change or impact to the
surrounding neighborhood due to access to and from the site. The proposed project meets all
required setbacks of the R1 zoning district and the Zoning Title. Therefore, the proposed project
will not be detrimental or injurious to property or improvements in the vicinity, and will not
be detrimental to the public health, safety, or welfare.
NOW, THEREFORE, BE IT RESOLVED:
That after careful consideration of maps, facts, exhibits, testimony, 'and other evidence
submitted in this matter, the Hearing Officer of the Administrative Hearing does
determine that, Application No. INT -2017-01, is categorically exempt from CEQA; and
approves said application; and
That the subconclusions upon which the findings and conditions specified in Section III
of this Resolution are based and contained in the public meeting record concerning
Application No. INT -2017-01 as set forth in the Minutes of the Administrative Hearing
Meeting of January 11, 2018, and are incorporated by reference herein.
SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY
DEVELOPMENT DEPARTMENT
1. APPROVED EXHIBITS
Approval is .based on the plan set entitled, "Sinn Residence: Proposed Addition &
Remodel, 1258 S. Stelling Rd., Cupertino, CA 95014," drawn by GP Residential
Designs dated September 21, 2017 consisting of nine (9) sheets labeled Al through A8;
and the boundary and topographic map entitled, "Preliminary Boundary and
Topographic Map Lands of Vasavakul" certified by Porfirio Oscar Osuna dated
November 17, 2017 consisting of two (2) sheets; except as may be amended by
conditions in this resolution.
Resolution No. 86 INT -2017-01 January 11, 2018
Page 3
2. ANNOTATION OF THE CONDITIONS OF APPROVAL
The conditions of approval set forth shall be incorporated into and annotated on the
building plans.
3. ACCURACY OF PROJECT PLANS
The applicant/property owner is responsible to verify all pertinent property data
including but not limited to property boundary locations, building setbacks, property
size, building square footage, any relevant easements, and/or construction records.
Any misrepresentation of any property data may invalidate this approval and may
require additional review.
4. COMPLIANCE WITH PUBLIC WORKS CONFIRMATION FORM -
The project shall comply with the requirements indicated on the Public Works
Confirmation form including, but not limited to, dedications, easements, off-site
improvements, undergrounding of utilities, all necessary agreements, and utility
installations/relocations as deemed necessary by the Director of Public Works and
required for public health and safety. The Public Works Confirmation is a preliminary
review, and is not an exhaustive review of the subject development. Additional
requirements may be established and implemented during the construction
permitting process. The project construction plans shall address these requirements
with the construction permit submittal, and all required improvements shall be
completed to the satisfaction of the Director of Public Works prior to final occupancy.
5. CONSULTATION WITH OTHER DEPARTMENTS
The applicant is responsible to consult with other departments and/or agencies with
regard to the proposed project for additional conditions and requirements. Any
misrepresentation of any submitted data may _invalidate an approval by the
Community Development Department.
6. FRONT YARD INTERPRETATION
An Interpretation is granted to allow the lot line adjoining S. Stelling Road to be
considered the front lot line. Any future additions or modifications to the residence
shall be consistent with the interpretation of the lot line adjoining S. Stelling Road as
the front lot line.
7. FENCES !
The location of all fences on the site shall be indicated on building permit plans,
comply with Chapter 19.48, Fences, of the Cupertino Municipal Code, and must be
reviewed and approved prior to issuance of building permits. The setback
requirements for all fences shall be consistent with the interpretation designating the
front lot line as S. Stelling Road and the street -side lot line as Rainbow Drive.
Resolution No. 86 INT -2017-01 January 11, 2018
Page 4
8. LANDSCAPING
The applicant shall provide landscaping in the required side yard setback between
the public right of way and the fence and/or retaining wall. Landscaping shall consist
of drought tolerant plantings, provide visual relief to the fence, and be appropriately
irrigated and maintained by the property owner.
9. ACCESORY BUILDINGS/STRUCTURES
The location of all existing and proposed accessory buildings and/or structures shall
be indicated on building permit plans and shall comply with Chapter 19.100,
Accessory Buildings/Structures, of the Cupertino Municipal Code for review and
approval prior to issuance of building permits.
10. DEMOLITION REQUIREMENTS
All demolished building and site materials shall be recycled to the maximum extent
feasible subject to the Building Official. The applicant shall provide evidence that
materials were recycled prior to issuance of final demolition permits.
11. DUST CONTROL
The following construction practices shall be implemented during all phases of
construction for the proposed project to prevent visible dust emissions from leaving
the site:
a. Water all active construction areas at least twice daily and more often during
windy periods -to prevent visible dust from leaving the site; active areas adjacent
to windy periods; active areas adjacent to existing land uses shall be kept damp at
all times, or shall be treated with non-toxic stabilizers or dust palliatives.
b. Cover all trucks hauling soil, sand, and other loose materials or require all trucks
to maintain at least 2 feet of freeboard;
c. Pave, apply water at least three times daily, or apply (non-toxic) soil stabilizers on
all unpaved access roads, parking areas and staging areas at construction sites.
d. Sweep streets daily, or more often if necessary (preferably with water sweepers) if
visible soil material is carried onto adjacent public streets.
e. The applicant shall incorporate the City's construction best management practices
into the building permit plan set.
12. GRADING AND CONSTRUCTION HOURS AND NOISE LIMITS
a. All grading activities shall be limited to the dry season (April 15 to October 1),
unless permitted otherwise by the Director of Public works.
b. Construction hours and noise limits shall be compliant with all requirements of
Chapter 10.48 of the Cupertino Municipal Code.
i
Resolution No. 86 INT -2017-01 January 11, 2018
Page 5
c. Grading, street construction, underground utility and demolition hours for work
done more than 750 feet away from residential areas shall be limited to Monday
through Friday, 7 a.m. to 8 p.m. and Saturday and Sunday, 9 a.m. to 6 p.m.
Grading, street construction, demolition or underground utility work within 750
feet of residential areas shall not occur on Saturdays, Sundays, holidays, and
during the nighttime period as defined in Section 10.48.053(b) of the Municipal
Code.
d. Construction activities shall be limited to Monday through Friday, 7 a.m. to 8 p.m.
and Saturday and Sunday, 9 a.m. to 6 p.m. Construction activities are not allowed
on holidays as defined in Chapter 10.48 of the Municipal Code. Night time
construction is allowed if compliant with nighttime standards of Section 10.48 of
the Cupertino Municipal Code.
e. Rules and regulations pertaining .to all construction activities and limitations
identified in this permit, along with the name and telephone number of an
applicant appointed disturbance coordinator, shall be posted in a prominent
location at the entrance to the job site.
f. The applicant shall be responsible for educating all contractors and subcontractors
of said construction restrictions.
The applicant shall comply with the above grading and construction hours and noise
limit requirements unless otherwise indicated
13. EXTERIOR BUILDING MATERIALS/TREATMENTS
The final building exterior plan shall closely resemble the details shown on the
original approved plans. Final building exterior treatment plan (including but not
limited to details on exterior color, materials, architectural treatments, doors,
windows, lighting fixtures, and/or embellishments) shall be reviewed and approved
by the Director of Community Development prior to issuance of building permits to
ensure quality and consistency. Any exterior changes determined to be substantial
by the Director of Community Development shall either, require a modification to this
permit or a new permit based on the extent of the change.
14. LANDSCAPE PROTECT SUBMITTAL
Prior to issuance of building permits, the applicant shall submit a full Landscape
Documentation Package, per sections 14.15.050 A, B, C, and D of the Landscape
Ordinance, for projects with landscape area 500 square feet or more or elect to
submit a Prescriptive Compliance Application per sections 14.15.040 A, B, and C for
projects with landscape area between 500 square feet and 2,500 square feet. The
Landscape Documentation Package or Prescriptive Compliance Application shall be
reviewed and approved to the satisfaction of the Director of Community
Development prior to issuance of building permits, and additional requirements per
Resolution No. 86 INT -2017-01 January 11, 2018
Page 6
sections 14.15.040 D, E, F, and G or 14.15.050 E, F, G, H, and I will be required to be
reviewed and approved prior to final inspections.
15. INDEMNIFICATION
Except as otherwise prohibited by law, the applicant shall indemnify and hold
harmless the City, its City Council, and its officers, employees and agents (collectively,
the "indemnified parties") from and against any claim, action, or proceeding brought
by a third party against one or more of the indemnified parties or one or more of the
indemnified parties and the applicant to attack, set aside, or void this Resolution or
any permit or approval authorized hereby for the project, including (without
limitation) reimbursing the City its actual attorneys' fees and costs incurred in defense.
of the litigation. The applicant shall pay such attorneys' fees and costs within 30 days
following receipt of invoices from City. Such attorneys' fees and costs shall include
amounts paid to counsel not otherwise employed as City staff and shall include City
Attorney time and overhead costs and other City staff overhead costs and any costs
directly related to the litigation reasonably incurred by City.
16. NOTICE OF FEES DEDICATIONS, RESERVATIONS, OR OTHER EXACTIONS
The Conditions of Project Approval set forth herein may include certain fees,
dedication requirements, reservation requirements, and other exactions. Pursuant to
Government Code Section 66020(d) (1), these Conditions constitute written notice of
a statement of the amount of such fees, and a description of the dedications,
reservations, and other exactions. You are hereby further notified that the 90 -day
approval period in which you may protest these fees, dedications, reservations, and
other exactions, pursuant to Government Code Section 66020(a), has begun. If you
fail to file a protest within this 90 -day period complying with all of the requirements
of Section 66020, you will be legally barred from later challenging such exactions.
PASSED AND ADOPTED this 11th day of January, 2018 at a noticed Public Meeting of
the Administrative Hearing Officer of the City of.Cupertino, State of California, held by
the Director of Community Development, or his or her designee, pursuant to Cupertino
Municipal Code Section 19.12.120.
ATTEST:
/s/Erika Poveda
Erika Poveda
Assistant Planner
APPROVED:
/s/Catarina Kidd
Catarina Kidd
Senior Planner
5
12'-5" BUILDING
24"
APPROVAL i&
An
Date
�1gna ur Is fbiw
SINN RESIDENCE
PROPOSED ADDITION & REMODEL
1258 S. STEELING RD
. • CUPERTINO, CA 95014
I.-
S. STEELING RD.
SCALE: 1/8"= 1'-0"
LINE
> FOOT HIGH
1OOD FENCING
EW ADDITION
IEW GARAGE
113 SQ. FT.
LTI TRUNK TREE
IE TREE
T. FRONT YARD AREA
PERVIOUS ALLOWED (775 SQ. FT.)
EW IMPERVIOUS AREA 440 SQ. FT.
PROJECT DATA
A.P.N # ....................... 366 -II -109
OCCUPANCY GROUP .......... R -3/U
CONSTRUCTION TYPE ........ V -B
ZONING ........................ R-1-6
LAND USE ..................... RES LOW 1-5
SCOPE OF WORK
• SINGLE STORY ADDITION AND MAJOR REMODEL WITH
NEW ROOF FRAMING SYSTEM
• RAISE EXISTING PLATE HEIGHT TO 10 FEET
LOT COVERAGE
LOT SIZE ................................................ 9,276 SQ. FT.
EXISTING DWELLING + PROPOSED ADDITION.......... 2,635 SQ. FT.
EXISTING GARAGE + PROPOSED ADDITION............ 545 SQ. FT.
PROPOSED PORCH ....................................... 37 SQ. FT.
24" OVERHANGS ........................................ 382 SQ. FT.
TOTAL LOT COVERAGE ................................ 3,599 SQ. FT.
TOTAL FOOT PRINT (W/OVERHANGS) = 0.39%
F. A. R
DWELLING ...................... 2,635 SQ. FT.
GARAGE ......................... 545 SQ. FT.
OVER 16' HEIGHT AREA....... 420 SQ. FT.
PARTIAL COVERED PORCH..... 14 SQ. FT.
TOTAL AREA = 3,614 SQ. FT.
TOTAL AREA = 0.39%
LOT SIZE
AREA CALCULATION
EXISTING DWELLING ............................... 1,234 SQ. FT.
PROPOSED NEW ADDITION ......................... 1,401 SQ. FT.
EXISTING GARAGE ................................. 432 SQ. FT.
PROPOSED NEW GARAGE EXPANSION............ 113 SQ. FT.
PROPOSED NEW FRONT PORCH ..................... 37 SQ. FT.
TOTAL LIVING AREA (1,234 + 1,401) = 2,635 SQ. FT.
Q
C)
L0
lJ..l
U z Q
Z J U
W
0 W O
Z
11.1
u
z 00 W
CL
z L0
(n N U
W
Z
O
N �
r �
J �4
a m
U) Uro
Z d 0 U
Z ,^ O.�_. t0
W V_ ' • E
2 N [nod
W U N L
d �
y
L
C
L
a
Date 09/21/17
Scale AS N07E0
Drawn GP
Job
SheetAl
DRAWING INDEX
Al
• SITE PLAN
AI I
• NEIGHBORING PROPERTIES
A2•
EXISTING FLOOR PLAN
• FLOOR AREA CALCULATION DIAGRAM
A3
10 PROPOSED FLOOR PLAN
ALE
• ROOF PLAN
A5 • CROSS SECTION
A6 -FRONT a REAR ELEVATION
A7
• LEFT 8. RIGHT ELEVATION
A8
• EXISTING ELEVATIONS
Q
C)
L0
lJ..l
U z Q
Z J U
W
0 W O
Z
11.1
u
z 00 W
CL
z L0
(n N U
W
Z
O
N �
r �
J �4
a m
U) Uro
Z d 0 U
Z ,^ O.�_. t0
W V_ ' • E
2 N [nod
W U N L
d �
y
L
C
L
a
Date 09/21/17
Scale AS N07E0
Drawn GP
Job
SheetAl
APPROVAL-
I W17- i I 0Da,�
Application Numbox
,v
i
I
I
i 1 DWELLING I
i
I
{ I
,
L _ _ _ _
7
/ 25'-8"
I
I
I '
` 16'-0"
NEIGHBORING PROPERTIES
SCALE: I"= 20'
Z
O
p �
W
(n p
O p
CL Q
O
x -3:
CL W
Z
o�
�c>
LO
W O O*1
U z Q
Z J U
W J
� LU O
U Z
W
W
Z ap
Z_ n Z)
(n N U
LU
z
0
0
J N m
mv'
Q Cn v�E
F— Z a o 8
Z S2 �� E
N wo@
Uj
W •
d
n/ �N:
I.L V7 d^ N
L O 6
Iry �
� O
C
N� s
a
Date 09/21/17
SCale AS NOTED
Drawn W
Job
SheeA1.1
1.1
II � II II Ij
II I II II I
II I II II I;
BDRM BDRM
I II
LJ iit ,i FAMILY RM.
! II� III` 1111 1 �j �-rr-
rr7
i m` it
T
L ------J I
I I
11 SII ��I II III
I I I I I/ \ I I tJ III
II II II III III
I I I I I I 111 III
ii BDRM n KITCHEN
I I I
I'LL �$� 1 L1.J i L-- iH I `�♦ 11 III
� �L
I II \ I 1 III
ii \\\\ it lii III i � ii l
/II 1 14 j
I'
Ij
II
\\ I
\ JI
li
I'
.E
I'
II
II
II
II
I'
II
II
II
II
II
II
II
II
II
II
II
II
EXISTING/DEMOLITION FLOOR PLAN
SCALE: 3/16"= 1'-0"
to
M
x
a
N
TOTAL FLOOR AREA = 3,614 SQ. FT.
FLOOR AREA CALCULATION DIAGRAM
SCALE: 3/16"= 1'-0"
z
0
LU _
U
0 p
IL a
0
x 3:
IL LLI
z
N�N
1 1 c)
C7 �
LLJ
U z Q
z J U
LLI J
0 LU �
� � Z
LU �NN
z LU
z 00 CL
(n N U
Of
w
z
0
0
J 4
Q rn v
Q
vi N U ,.., O
ZZ
o
Ur o�E
W
•
0 U) n o
W =°
N m
VJ m
rn �
0
ma
Date 09/21/17
Scale AS NOTED
Drawn W
Job
Sheet ^
Applicaiion Number
F e i
WALL LEGEND
C"u�a;'"s9.:<.9�
'T�'
^�
L`�jn
SECTION
A
DIMENSIONS
5'-4" x 5'-4"
AREA
28 SQ. F7.
EXISTING WALL TO REMAIN
ger
B
8'-0" X 37'-0"
295 SQ. FT.
C
30'-4" x 50'-4"
1,532 SQ. FT.
DEMO EXISTING WALL
D
3'-I' x 10'-9"
33 SQ. FT.
E
2'-0" X 12'-7"
25 SQ. FT.
F
2'-0" X 7'-0"
14 SQ. FT.
G
24'-1" X 52'-6"
1,267 SQ. FT.
H
21'-0" X 20'-0"
420 SQ. FT.
II � II II Ij
II I II II I
II I II II I;
BDRM BDRM
I II
LJ iit ,i FAMILY RM.
! II� III` 1111 1 �j �-rr-
rr7
i m` it
T
L ------J I
I I
11 SII ��I II III
I I I I I/ \ I I tJ III
II II II III III
I I I I I I 111 III
ii BDRM n KITCHEN
I I I
I'LL �$� 1 L1.J i L-- iH I `�♦ 11 III
� �L
I II \ I 1 III
ii \\\\ it lii III i � ii l
/II 1 14 j
I'
Ij
II
\\ I
\ JI
li
I'
.E
I'
II
II
II
II
I'
II
II
II
II
II
II
II
II
II
II
II
II
EXISTING/DEMOLITION FLOOR PLAN
SCALE: 3/16"= 1'-0"
to
M
x
a
N
TOTAL FLOOR AREA = 3,614 SQ. FT.
FLOOR AREA CALCULATION DIAGRAM
SCALE: 3/16"= 1'-0"
z
0
LU _
U
0 p
IL a
0
x 3:
IL LLI
z
N�N
1 1 c)
C7 �
LLJ
U z Q
z J U
LLI J
0 LU �
� � Z
LU �NN
z LU
z 00 CL
(n N U
Of
w
z
0
0
J 4
Q rn v
Q
vi N U ,.., O
ZZ
o
Ur o�E
W
•
0 U) n o
W =°
N m
VJ m
rn �
0
ma
Date 09/21/17
Scale AS NOTED
Drawn W
Job
Sheet ^
I
WALL LEGEND
EXISTING WALL TO REMAIN a
DEMO EXISTING WALL
PROPOSED NEW WALL
W/ 2X4 DF#2 STUDS
@ 16" O.C., TYP.
2 I
A5 A5
�To� I O
W
18'-0" 28'-1" U Q
I I CL Q
EL W
8'-4" MASTER DINING Z
BDRM. 16'-0" RM.
GREAT
RM.
I I
5'-0"
29'-2"
I
Y-6"
I o
8'-10" 8'-10" 5'-4"
4'X8' ISLAND
I 6'-8"
12'-11' BDRM. 5'-0.. 4'-0"
KITCHEN
4'-O"
C)
4'-0" REF. OVEN O 4'-0" LO
W U 0%
U Z Q
® Z J U
EA7 0 23'-5" W
p W O
5'-6"in w V Z
-o" OFFICE T-11" _ W
10'-0°
Z 00 CL
12'-3" 4'-0" Z
FOYER I 2 -CAR C/5N L)
GARAGE 22'-°"
LU
z
0
I I
BDRM.
N
BDRM. a N 'UN E
8'-10"
I I ZZ °<$
12'-3° W •
N mom
W .;
12'-3° 5'-" PORCH LUN
APPROVAL '1'L� � I to
Application Numberm =
m C
a.
fi � 11 N
.—j I— / ` Date ' 09/21/17
n Da'`d-
SCOIe AS NOTO
o ��'`"gnah_-_ ur8 M �� Drawn GP
lar n��r PROPOSED FLOOR PLAN
SCALE: 1/4"= 1'-0" Job
Sheet
H A
�o
M
x
N
e
S
2 I
A5 A5
(N) ROOF TRUSSES g
�I _ \ I
�-\------- -� i }---------------------
\"7�7
\\ til/ I /
z
0
\ / W
00
OL. Q
IL W
I I
4-12-
4:12W z �
\ I z J U
/ \ I W -J
LLJ
/ (n
00 CL
N U
z
0
/ 2 I 4•12a I I I I \\
I X4:12 I _4:Iz_ I JQ a�
Y
(n U r- o
L-------------- � z� ��E
W .
o N Nom
W N
ami ' a
APPROVALFISP � -�Y7-0f � m
Application Number
DRO
Date 09/21/17
�
-L���� ROOF PLAN
�' ,�� Scale AS NOTM .,,,_ _ SCALE: I/4"= I'-0"
o Drawn GP
Case, "Mia aasgar
a Job
Sheet A q
x H L�.
rn
m
r)
x
N
(N) ROOF TRUSSES
ATTIC SHALL NOT BE USED AS HABITABLE SPACE
12
Q4 i
Z
O
BDRM BATHROOM HALLWAY WALK-IN MASTER W F
CLOSET 10 -° BDRM. U)
O
O Q
lx 3:
�- W
Z
\—BAYWINDOW
79===
CROSS SECTION 2
SCALE: 3/8"= 1'-0" q5
(N) ROOF TRUSSES
ATTIC SHALL NOT BE USED AS HABITABLE SPACE Q
L0
LU 0
U Z Q
Z J U
W J
W O
12
Q4 (n cl) Z
L1J
LU
z 00 rL
19'-0" Z Lr)
20'-0° (n N U
w
z
0
PORCH 2-CAR KITCHEN GREAT 10'-0°
GARAGE RM. a <N E
Z Z o
3LLj_ V E
N
In woo8
cf)W • m .E
W c
LU S N
N 12
G PP R V®"tL NATURAL GRADE N °n
.a
Application Number
9 , , Date 09/21/17
Scale IAS NOTED I D2,te,
,{ a r, Drawn 0P
F''k' `''�`LCROSS SECTION 1
1 �- - Job
'l ea)n. 1�er SCALE: 3/8"= I'-0" A5
Sheet
to
M
x
sh
N
2
APP ROWA -IN 1 17 - 0 If
Applicati®n Number
crap !qnip
0- " LI
THIS AREA OVER 16'-0" IN HEIG
IS DOUBLE COUNTED IN F.A.R.
PROPOSED FRONT ELEVATION (WEST)
SCALE 1/4"= 1'-0"
THIS AREA OVER 16'-0" IN HEIGHT
IS DOUBLE COUNTED IN F.A.R.
REAR ELEVATION (EAST)
SCALE: 1/4"= V-0"
STONE VENEER
TURAL GRADE
PLEASE NOTE:
ANY CHANGES TO THE APPROVED COLORS, MATERIALS,
AND EXTERIOR FINISHES SHALL BE REVIEWED AND
APPROVED BY THE CITY OF CUPERTINO PLANNING
DIVISION PRIOR TO INSTALLATION/APPLICATION.
N
64
U) aNEo
l
Z
LZ LD -E
Ll ■m
Cl U) @)
F) Lu
LLJ
It
vi m
20
.
4&vj . (L
Date 09/21/17
Scale AS NOTED
Drawn GP
Job
Sheet
A6
THIS AREA OVER 16'-0" IN HEIGHT
IS DOUBLE COUNTED IN F.A.R.
a
ROOF TILE
. . . .. . . . . . . . .
SO IR�-
ROOF TILE
A .
4D
Z
20'-0"
0
16'-0"
0
w _
(n p
S NG NG=I,
0
ER
IL Q
2'-4" -
�- W
NATURAL GRADEATX
Z
LIGHT WEIGHT CANTILEVERED BAY WINDOW
STONE VENEER
ANTILEVERED BAY WINDOW
LEFT SIDE ELEVATION (NORTH)
SCALE: I/4"= 1'-0"
THIS AREA OVER 16'-0" IN HEIGHT
IS DOUBLE COUNTED IN F.A.R.
Q �_
C>
U-)
V..I
Z
- - - -
[ROOF TILE
U Q
J U
W -
w
u J
f—
Z C/O Z
LJ .I
ui
z �
z
Cn cV U
20'-0"
Lu
Z
O
16'-O"
Q.4
O
53
Z Lu
❑V/ NW
-v-a-
AL
�
it
..0APPRO
W�
>u
r v �
Application NB. mbar4
N
rng
�a
DRCI I
I _, �'!
RIGHT SIDE ELEVATION (SOUTH)
Date 09121r7
D J
SCALE: 1/4"= 1'-0"
Scale AS NOTO
II
�.
e� 3 g _
i g tl,�3E a
--
PLEASE NOTE:
ANY CHANGES TO THE APPROVED COLORS, MATERIALS,
Drawn cP
o
case. liviana er
J
AND EXTERIOR FINISHES SHALL BE REVIEWED AND
Job
APPROVED BY THE CITY OF CUPERTINO PLANNING
In
m
'
DIVISION PRIOR TO INSTALLATION/APPLICATION.
Sheet
A7
M
X
4
N
/`0..
TO PROPERTY LINE
MMW
NEEMMINMENEEMIN
WEENNEENERENOMMUNNE
MMEEMEE
rA Fl.
I Fil
Fil Fil
EXISTING FRONT ELEVATION (WEST
SHINGLES
EXISTING REAR ELEVATION (EAST)
EXISTING LEFT SIDE ELEVATION (NORTH)
�
�
04
:
..
--m`0"--
EXISTING RIGHT SIDE ELEVATION (SOUTH)
is )
I� I
FOUND Cm
S8gJ032� J2fi MONUMENT S/
� lel
N
7rryff
dap460a rv`822' R 1pa
00'
'�`• f: °'0'M'12 S69'46'44 W 50.02'
•o5s 41. Sfie Js �.. `.. It
a po2a0O. 31� �' •... fo
.d
LOT 203 ^�
�N R1 N� LOT 63
I APN NO.: 366-11-109 R1
z
LOT GROSS AREA 9,2784 SF
N89'47_47 E 100.00'
LOT 202 i" LOT 86
v R1 RI
i
— NRS'4T47E 200.00'
Q
C7
Z
LLJJ
J
H
I�
ABREVRATIONS
FL FLOW LINE ELEVATION
IP IRON PIPE
L CURVE LENGTH
R!REFERENCE DOCUMENT
N -M MONUMENT TO NONUMI
O.H. PWR OVERHEAD POWER UNE
TC TOP OF CURB ELEVATION
TEMP. TEMPORARY
PILE PUBLIC UTILITY EASEMENT
WLE WATER LINE EASEMENT
QYO.L LAgd _])
�" POINlRO �GPa q y
rc OSGA OSIIi1 0 � � S�
Xo 8971 CY �lI
$,YAfYY' GLIB �
Q
U_
CE
Q.
CJ �
O 3c
Zd z
>p -
NOTES:
LEGEND
EXISIING CONTWB LEE
---2OD-•--
�.
— —
()
NATURAL GRADE CONTOUR LINE
FOUND CITY MONUMENT BOX, OR AS NOTED
BOUNDARY OF PROPERTY SURVEYED
RECORD INFORMATION
—
—CENTERLINE
CURB INET
CURB LINE
^�
i..../�
d
B
DRIVEWAY APRON
EIECTROUEA
FENCE
FIRE HYDRANT
MT GRATE 4NET
ox rm—
—
0
O
OVERNLND POWER LINE
OVERHEAD TELEPHONE LINE
— SANITARY SLIVER LINE
SWART SEWER MANHOLE
SWARY SEWER CLEANOUT
SIGN
v
so
00
o
o
•—
M
Y.
®
HI
Go
STORM GRAN LINE
STORM MAN MANHOLE
UTIUIY BOX
UOLRY POLE
WATER LINE
WATER METER
WATER VALVE
ELECTRIC METER
WATER HEATER
Gly
is )
I� I
FOUND Cm
S8gJ032� J2fi MONUMENT S/
� lel
N
7rryff
dap460a rv`822' R 1pa
00'
'�`• f: °'0'M'12 S69'46'44 W 50.02'
•o5s 41. Sfie Js �.. `.. It
a po2a0O. 31� �' •... fo
.d
LOT 203 ^�
�N R1 N� LOT 63
I APN NO.: 366-11-109 R1
z
LOT GROSS AREA 9,2784 SF
N89'47_47 E 100.00'
LOT 202 i" LOT 86
v R1 RI
i
— NRS'4T47E 200.00'
Q
C7
Z
LLJJ
J
H
I�
ABREVRATIONS
FL FLOW LINE ELEVATION
IP IRON PIPE
L CURVE LENGTH
R!REFERENCE DOCUMENT
N -M MONUMENT TO NONUMI
O.H. PWR OVERHEAD POWER UNE
TC TOP OF CURB ELEVATION
TEMP. TEMPORARY
PILE PUBLIC UTILITY EASEMENT
WLE WATER LINE EASEMENT
QYO.L LAgd _])
�" POINlRO �GPa q y
rc OSGA OSIIi1 0 � � S�
Xo 8971 CY �lI
$,YAfYY' GLIB �
Q
U_
CE
Q.
CJ �
O 3c
Zd z
>p -
NOTES:
® �a
p m
I. DISTANCES AND DIMENSIONS ARE SHOWN IN FEET AND DECIMALS THEREOF.
2. THE DISTWCTIVE BORDER LINE DENOTES THE BOUNDARY.j
101 '
O n
3. TREES SPECIES NAMES ARE APPROXIMATE, AND LABELED BY THBR COMMON NAME
TO THE BEST OF OUR KNOWLEDGE. R IS NOT BASED ON AN ARBORIST REPORT.
p Z N .
20 g�z
4.THIS NAPS REPRESENTS TOPOGRAPHY OF THE SURFACE FEATURES ONLY.
5. UNLESS SPEGFlED ON THIS AIM, LOCATIONS OF THE UNDERGROUND AND
O�
E
Ij5
OVERHEAD UTILITIES ARE NEITHER RITMDM NOR IMPLIED. FOR THE LOCATIONS OF
T
¢
UNDERGROUND UTILITIES CALL -USA' (1-800-642-2440).
fi. BUILDING FOOTPRINTS ARE SHOWN AT GROUNO LEVEL.
Z
¢
7. FINISH FLOOR ELEVATION TAKEN AT DOOR THRESHOLD (EXTERIOR).
8. A TOLE REPORT FOR THE SUBJECT PROPERTY HAS NOT BEEN EXAMINED BY
qia
GREENBLUEARTH, INC. OTHER EASEMENTS OF RECORD MAY EXIST THAT ARE NOT
J
LLI
SHOWN ON THIS ANAP.
a
® �a
101 '
O�
T
qia
_a
GO
.•...... _-z`.�`F.. .......
--. 200-.--
—ox Tu— OVERHEAD TELEPHONE LINE
LEGEND
EXISTING CONTOUR LEE
NATURAL GRADE CONTOUR LEE
p.
— —
()
— —
FOUND CRY MONUMENT BOX, OR AS N TED
— BOUNDARY OF PROPERTY SUR& ED
RECORD INFORMATION
—CFMEAUE
A
CURB INET
CURB UNE
^�
)._.:
d
e
ax vvn—
DRIVEWAY APRON
ELECTROIEA
FENCE
FIRE HYDRANT
FLAT GRATE TIBET
OVERHEAD POWEN LEE
EX. UTILITY POLE
SANITARY SEWER LEE
Q SANITARY SEWER MANHOLE TC
® SANITARY SEWER CLEANOUT
SIGN
STORM MAIN LEE
Oo STORM ONMN MANHOLE
o UIIDITY Box c WATER 4-
unurr
POLE
v— WATER LEE 2B'
k WATER HERR
x WATER VALVE
® ELECTRIC METER
® WATER HEATER
IID GAS 1p'
10' PINI
24' TREE Yd
TC
EX. FIRE HYDRANT—
EX
YDRANT EK WATER METER
EX. UTILITY POLE
T�1
ETI. ATER VALVE
31
3
i
2
Z$
\ "f
I
\ NI
\ Le�7F !f
aar
IB,TZ, 1
'-�TC /
1
1
f
fy
1<
1�
to
\56,9'1 !n
1'a UTILITY POLE
+� T 29
\ 1 w
I
e4569 1
+ 'i'1�e00,
r\ l
+ \r
EX. HOUSE
FF 000.0
LOT 203
R1 bl
MN NO.: 766-11-109
EX. GARAGE
LOT GROSS AREA. 9,2763 SF
—.. I
N89'477 47'E 100.00'
17' MULTI TRUNK TREE
10' PINE TREE
I
I
Im
IP'
b
I
ABREVIATIONS
MN ASSESSOR'S PARCEL NUMBER
BN BENCH NARK
CAN CABLETELEM90N OVERHEAD
D CURVE DELTA
DRAY DRIVEWAY
DS DOWNSPOUT
FL FLOW LINE ELEVATION
IP IRON PIPE
L CURVE LENGTH
R% REFERENCE DOCUMENT
N -M MONUMENT TO MONUMENT
O.H. PWR OVERHFAD POWER LINE
O.H. TEL OVERHEAD TELEPHONE LINE
PCL PARCEL
P.N. PARCEL. MAP
PLN PORTION
R RADIUS
SD STORM DRAIN
SS SANITARY SEWER
TC TOP OF CURB ELEVATION
TEMP. TEMPORARY
PUE PUBLIC UTILITY EASEMENT
WILE WATER UNE EASEMENT
4`'\O�L LAAO sp � l
ePOAFlPoO c � � �_I
OBGR 09741 `Nil(
F�. 9 -78 -IB i
�rFO- [AL1f�
NOTES:
1. DISTANCES AND DIMENSIONS ARE SHOWN IN FEET AND DECIMALS THEREOF.
2. THE DISTINCTIVE BORDER LINE DENOTES THE BOUNDARY.
0. TREES SPECIES NAMES ARE APPROXIMATE, MO LABELED BY THEIR COMMON NAME
TO THE BEST OF OUR KNOWLEDGE R IS NOT BASED ON M ARBORIST REPORT.
4.THIS NMS REPRESENTS TOPOGRAPHY OF THE SURFACE FEATURES ONLY.
5. UNLESS SPECIFIED ON THIS MAP, LOCATIONS OF THE UNDERGROUND AND
OVERHEAD UTILITIES ARE NEITHER INTENDED NOR IMPLIED. FOR THE LOCATIONS OF
UNDERGROUND UTILITIES CALL 'USA' (1-800-642-2440).
6. BUILDING FOOTPRINTS ME SHOWN AT GROUND LEVEL
7. FINISH FLOOR ELEVATION TAKEN AT DOOR THRESHOLD (EXTERIOR).
8. A TITLE REPORT FOR THE SUBJECT PROPERTY HAS NOT BEEN EXAMINED BY
GREENBLUEAATH, INC. OTHER EASEMENTS OF RECORD MAY EXIST THAT ARE NOT
SHOWN ON THIS MAP. .
I
1
OF
A'tl
CL
1
0�'r
ES
f
<
I
1
OF