Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
TUP-2017-06 Approved Plan Set.pdf
I:\0-Dwg2017\17119 Apple DA4 (Charles S)\Bitmap3574854015-1.jpgAPPLE PROJECT NO.DATE:NO.PROJECT NO:SCALE:DRAWN BY:REVIEWED BY:APPROVED BY:ARCHITECT:DESCRIPTION:PROJECT INFO:CLIENT:HAYES GROUP ARCHITECTS, INC.2657 SPRING STREETREDWOOD CITY, CA 94063P: 650.365.0600F: 650.365.0670www.thehayesgroup.comKEY PLAN:ISSUED FOR PERMIT11/06/171613.01AS NOTEDKVBNHPLAN CHECK RESPONSE11/08/17ES-1 3/32" = 1'-0"1GARAGE - POWER PLAN4'8'016'2'TEMPORARY POWER PLAN4.1G 1/4" = 1'-0"2ENLARGED MAIN ELECTRICAL & UPS ROOM - EXISTING TO REMAIN2'4'08'1'5GN.T.S.3TEMPORARY POWER SINGLE LINE DIAGRAMPOWER SHEET NOTES:SCOPE OF WORK:DRAWING INDEX: Sheet 1 of 2 Part Name: A030Y946 Revision: E Drawing Name: A040U609 Revision: D ©2009 Cummins Power Generation. Cummins and PowerCommand are registered trademarks of Cummins Inc. Specifications are subject to change without notice. S-1553b (1/09) Rental Power 300 kW Description This Cummins Power Generation rental package is a fully integrated mobile power generation system, providing optimum performance, reliability and versatility for standby and prime power applications. Features Cummins diesel engines • U.S. EPA Tier III compliant • Rugged 4-cycle industrial diesel engine with excellent transient performance • Lightweight, compact and excellent fuel economy • Spin on fuel filter w/pre-filter water separator with drain • Equipped with heavy duty, 2-stage air cleaners with dust ejector and bypass-type oil filters Control features • The most advanced, reliable and capable generator set control system on the market today. • Controls provide precise frequency and voltage regulation, alarm and status message display in one easy-to-operate customer interface. • Remote monitoring and operation ready • Auto shutdown at fault detection Engine controls • Oil Pressure & Water Temp Gauge • Fuel Level Gauge & Battery Voltage Gauge • Hour meter Stamford alternators • 12-lead reconnectable alternators fitted with voltage selection switch • Permanent magnet excitation for improved performance in non-linear load applications Rental package enclosure • Heavy duty trailer package with pintle hitch and electric or hydraulic brakes • Sound attenuated, white powder coated lockable enclosure • 20 hour fuel tank (100% prime) with gauge • Roof mounted, single point lift • Cooling system rated for 122° F (50° C) ambient • Complete engine fluid containment reservoir • DOT approved trailer with light package, replaceable fenders and jack stand • Low coolant shutdown feature • Voltage selector switch • Shore power (120 VAC) – No breakers in shore power connection. Shore power loads are coolant heater (option) and battery charger (option). Connection: 15A/120V flanged male receptacle (5-20 flanged inlet). Standby rating Prime rating Model Voltages (V) 60 Hz kW (kVA) 50 Hz kW (kVA) 60 Hz kW (kVA) 50 Hz kW (kVA) Engine model Alternator model C300D6RT 208/480 300 (375) 270 (337) QSM11-G4 HCI434E 480/600 switchable 300 (375) 270 (337) QSM11-G4 HCI434F Our energy working for you.™ www.cumminspower.com ©2009 Cummins Power Generation. Cummins and PowerCommand are registered trademarks of Cummins Inc. Specifications are subject to change without notice. S-1553b (1/09) Engine specifications Engine model QSM11-G4 Alternator data sheet HCI434E (208/480), HCI434F (480/600 switchable) Engine data sheet FR-20138 Tier rating Tier III Design 4 cycle, In-Line, turbocharged and after-cooled Bore 125 mm (4.92 in) Stroke 147 mm (5.79 in) Displacement 10.8 liters (661 in3) Cylinder block Cast iron, in-line 6 cylinder Battery capacity 1000 CCA GR31 Battery charging alternator 70 amps Starting voltage 24 volt, negative ground Fuel system Cummins Celect: No.2 diesel fuel Fuel filter Spin on fuel filter with water separator Air cleaner type 2-stage, dry replaceable element with dust ejector Lube oil filter type(s) Full flow bypass combo filter Standard cooling system 122° F (50° C) ambient radiator Alternator specifications Design Brushless, 4 pole, drip proof revolving field Stator 2/3 pitch Rotor Singe bearing, flexible disc Insulation system Class F per NEMA MG1-1.65 Standard temperature rise 95/50 ºC prime Exciter type PMG (permanent magnet generator) Phase rotation A (U), B (V), C (W) Alternator cooling Direct drive centrifugal blower fan AC waveform total harmonic distortion < 1.5% no load, < 5% non-distorting balance linear load Telephone influence factor (TIF) < 50 per NEMA MG1-22.43 Telephone harmonic factor (THF) < 2% Power capability specifications (Assume power factor = 0.80 for 3 phase amps) Standby rating 240 V, 1 phase Amps 208 V, 3 phase Amps 480 V, 3 phase Amps 600 V, 3 phase Amps C300D6RT 903 1040 451 361 Electrical power panel specifications Model voltage 120 V duplex receptacles 240 V twist Load lug connection (stud diameter) Load lug circuit breakers 120/480 Volt 2 - 20 Amp 3 - 50 Amp 1/2 inch 1200 Amp 480/600 Volt switchable 0 0 1/2 inch 600 Amp Site derating factors Standby application: The engine may be operated at 1800 rpm up to 305 m (1000 ft) and 50° C (122° F) without power deration. For sustained operation above these conditions, derate by 4% per 300 m (1,000 ft), and 11% per 10° C (18° F). Our energy working for you.™ www.cumminspower.com ©2009 Cummins Power Generation. Cummins and PowerCommand are registered trademarks of Cummins Inc. Specifications are subject to change without notice. S-1553b (1/09) Control system PowerCommand control • Integrated automatic voltage regulator and engine speed governor • Control components designed to withstand the vibration levels typical in generator sets Standard control description • Analog AC frequency meter • Analog AC voltage meter • Cycle cranking control • Digital display panel • Idle mode control • Menu switch • Panel backlighting • Remote starting, 12 V, 2 wire • Reset switch • Run-off-auto switch • Sealed front panel, gasketed door • Self diagnostics • Voltmeter/ammeter phase selector switch Standard performance data warnings • High coolant temperature • High DC voltage • Low coolant temperature • Low DC voltage • Low oil pressure • Over current • Weak battery • Over speed • Under frequency • Intake manifold temperature OOR high/low • Intake manifold temperature high • Water in fuel OORH/OORL • General engine fault • Coolant level OOR high/low Standard protection functions • Voltmeter/ammeter phase selector • Warnings • High coolant temperature • High DC voltage • Low coolant temperature • Low DC voltage • Low oil pressure • Over current • Weak battery Shutdowns • Emergency stop local/remote • Fail to crank • High AC voltage • High coolant temperature • Low coolant level • Low AC voltage • Low oil pressure • Over current • Over speed • Under frequency • Intake manifold temperature High • Fail to start/stop • Over frequency • Alternator reconnecting switch operated (breaker closed) Agency approvals • NFPA110 for Levels 1 or 2 systems • ISO 8528-4: 1993 Compliance, Controls and Switchgear • CE Marking • EN 50081-1, 2 Residential/Light Industrial Emissions or Industrial Emissions • EN50082-1.2 • ISO 7637-2, Level 2: DC supply surge test • Mil Std 202C, Method 101 and ASTM B117: Salt Fog Test • Designed and manufactured in ISO9001 certified facilities. Suitable for use on generator sets that are UL 2200 Listed. Standard generator electrical features • Multiple voltage selector switch (480/277 VAC/3 phase or 240/139 VAC/3 phase or 240/120 VAC/1 phase) • Potentiometer adjustable to 208/120 VAC/3 phase • Single phase convenience receptacles • Voltage adjustment potentiometer • Distribution panel with L1, L2, L3 neutral & ground • Main line shunt trip type circuit breaker • Auto start-stop with remote contacts • Over current sensing • 3 available auxiliary connections Rental package options • Heavy duty jack stand – center mounted • Immersion style coolant heater • Tank style coolant heater • Low coolant shutdown system (standard on 300 kW) • Phase selector switch on control panel • Battery disconnect switch • Cam lock distribution panel • 110 Volt, 3.5 Amp Sens battery charger • Base mount generator – no trailer • 600 Volt/480 Volt switchable Our energy working for you.™ www.cumminspower.com ©2009 Cummins Power Generation. Cummins and PowerCommand are registered trademarks of Cummins Inc. Specifications are subject to change without notice. S-1553b (1/09) Ratings definitions Standby: Applicable for supplying emergency power for the duration of normal power interruption. No sustained overload capability is available for this rating.(Equivalent to Fuel Stop Power in accordance with ISO3046, AS2789, DIN6271 and BS5514). Nominally rated. Prime (unlimited running time): Applicable for supplying power in lieu of commercially purchased power. Prime power is the maximum power available at a variable load for an unlimited number of hours. A 10% overload capability is available for limited time. (Equivalent to Prime Power in accordance with ISO8528 and Overload Power in accordance with ISO3046, AS2789, DIN6271, and BS5514). Dimensions Model Dim “A” mm (in.) Dim “B” mm (in.) Dim “C” mm (in.) Weight w/o fuel kg (lbs) Weight with fuel kg (lbs) Fuel capacity liters (gal) C300D6RT 4191 (165) 1575 (62) 2439 (96) 4740 (10450) 6000 (13227) 1514 (400) With trailer 6223 (245) 2489 (98) 2921 (115) 5792 (12770) 7094 (15540) 1514 (400) Specifications Model KW rating Sound level Tier rating Hours of operation (75% load) Standby Prime dB(A) @ 7 m Standby Standby Prime C300D6RT 300 270 75 Tier III 23 26 Fuel consumption Standby Prime 60 Hz Ratings, kW (kVA) 300 (375) 270 (337) Load ¼ ½ ¾ Full ¼ ½ ¾ Full Gal/hr 7.2 11.8 17 23 6.5 10.8 15 19.8 L/hr 27.3 44.7 64.4 87.1 24.6 40.9 56.8 75 Trailer information Model Tire size Tire type Load range Number of tires per trailer Lug pattern Wheel brand C300D6RT ST235/85R16 E 6 8 x 6.5 Cummins Power Generation 1400 73rd Avenue N.E. Minneapolis, MN 55432 USA Telephone: 763 574 5000 USA Toll-free: 877 769 7669 Fax: 763 574 5298 A C B Our energy working for you.™ www.cumminspower.com 2014 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Specifications are subject to change without notice. S-1443Y (A037S884) (12/16) Enclosures and tanks 250-1000 kW gensets Enclosure standard features 14-gauge steel construction (panels) Stainless steel hardware Zinc phosphate pretreatment, e-coat primer and super durable powder topcoat paint minimize corrosion and color fade Package listed to UL 2200 Designed to satisfy National Electrical Code installation requirements Fuel and electrical stub-up area within enclosure perimeter Fixed louvers Cambered roof prevents water accumulation Recessed, lockable doors in two sides Retainers hold doors open for easy access Enclosed exhaust silencer ensures safety and protects against rust Rain cap Exterior oil and coolant drains with interior valves for ease of service Rodent barriers on inlet Non-hydroscopic sound attenuating material Side mounted controls and circuit breakers Easy access lifting points for spreader bars Dual vibration isolation system (250-500 kW) Spring vibration isolation system (600-1000 kW) Enclosure mounts to lifting base or fuel tank (250-500 kW) Enclosure mounts to lifting base (600-1000 kW) Factory pre-assembled package Designed for outdoor use only Externally mounted emergency stop button for operator safety (optional on 250-500 kW) Horizontal air discharge to prevent leaf and snow accumulation (600-1000 kW) Options Three levels of sound attenuation Motorized louvers to protect from ice and snow accumulation (available on air inlet for all models and on air outlet on level II, 250-500 kW enclosures only) Horizontal air discharge, sound level 2 only (250-500 kW) Aluminum construction with roll-coated polymer paint Wind rated to 150 mph Neutral sandstone paint color Factory mounted battery charger External 120 VAC service outlet Rain hoods for air inlet (250-500 kW) Lifting base in lieu of a sub-base tank (250-500 kW) - Pre-wired AC distribution package - 100 amp (250-500 kW) or 150 amp (600-1000 kW) main circuit breaker; connected to 120 VAC line- neutral and 208 or 240 VAC line-line, spare breaker positions and capacity for future upgrades (600- 1000 kW) - GFCI protected internal 120 VAC service receptacle - GFCI protected weather proof external 120 volt service receptacle - All factory installed AC powered features pre-wired into load center Interior lights – 120 volt (600-1000 kW) Rain hoods for air inlet (250-500 kW) Seismic isolators available (600-1000 kW) Our energy working for you.™ www.cumminspower.com 2014 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Specifications are subject to change without notice. S-1443Y (A037S884) (12/16) Fuel tanks Standard sub-base tank features UL 142 Listed ULC-S601-07 Listed NFPA37 compliant Dual walled, steel construction Emergency tank and rupture basin vents Tank mounted mechanical fuel gauge Fuel supply and return tubes Top mounted leak detection float switch Low and high level fuel switches Mounting brackets for optional pump and control (250-500 kW) Integral lifting points Sub-base tank options Pre-wired fuel pump and control Fuel overfill alarm – internal or external Overflow and tank fill plugs Five gallon spill fill box – internal or external Fill pipe extender Local code approvals available 200-500 kW dual wall sub-base fuel tanks – usable operating hours Genset model (60 Hz) Gallons /hour at full load 270 gallo n tank 300 gallo n tank 400 gallo n tank 500 gallo n tank 600 gallo n tank 660 gallo n tank 720 gallo n tank 850 gallo n tank 1420 gallo n tank 1470 gallo n tank 1700 gallo n tank 2050 gallo n tank 2525 gallo n tank 250 DQDAA 20 14 15 20 25 30 33 36 72 74 104 275 DQDAB 21 13 14 19 24 29 31 34 66 70 96 300 DQDAC 23 12 13 17 22 26 29 31 61 64 88 300 DQHAB 23 12 13 17 22 26 29 37 74 450 DFEJ 30 9 10 13 17 20 22 28 57 84 500 DFEK 34 8 9 11 15 18 19 25 50 74 Operating hours are measured at 60 Hz, standby rating. 600-1000 kW dual wall sub-base fuel tanks – usable operating hours Genset model Gallons /hour at full load 200 gallo n tank 660 gallo n tank 1000 gallo n tank 1500 gallo n tank 2000 gallo n tank 2400 gallo n tank 600 DQCA 42 5 16 24 36 48 57 600 DQPAA 45 4 15 22 33 44 53 650 DQPAB 50 4 13 20 30 40 48 750 DQCB 51 4 13 20 29 39 47 750 DQFAA 53 4 12 19 28 38 45 800 DQCC 53 4 12 19 28 38 45 800 DQFAB 56 4 12 18 27 36 43 900 DQFAC 64 3 10 16 23 31 38 1000 DQFAD 72 3 9 14 21 28 33 *3000 gallon tank offered as an accessory kit – refer to NAAC-5853 spec sheet - Operating hours are measured at 60Hz, standby rating. - Up to 90% fill alarm to comply with NFPA30, operating capacity is reduced by 10%. . Our energy working for you.™ www.cumminspower.com 2014 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Specifications are subject to change without notice. S-1443Y (A037S884) (12/16) Enclosure package sound pressure levels @ 7 meters dB(A) Genset model Weather protective enclosure (F200, F203) QuietSite Level 1 sound attenuated enclosure (F201, F204) QuietSite Level 2 sound attenuated enclosure (F202, F205) 250 DQDAA 90 88 72 275 DQDAB 90 88 73 300 DQDAC 90 88 73 300 DQHAB 89 88 76 450 DFEJ 88 85 74 500 DFEK 89 87 73 600 DQCA 86/86* 82/78* 74/73* 600 DQPAA 89 81 77 650 DQPAB 90 81 80 750 DQCB 88/87* 83/79* 75/74* 750 DQFAA 89 79 75 800 DQCC 88/87* 83/79* 75/74* 800 DQFAB 89 79 75 900 DQFAC 89 80 76 1000 DQFAD 90 80 76 - All data is 60Hz, full load standby rating, steel enclosures only. - Data is a measured average of 8 positions. - Sound levels for aluminum enclosures are approximately 2 dB(A) higher than listed sound levels for steel enclosures. * Sound data with seismic feature codes L228-2 (IBC) and/or L225-2 (OSHPD) Package dimensions of enclosure, exhaust system, and UL tank 250-500 kW Tank size (gal) Weather protectiv e package length (in) QuietSite level I package length (in) QuietSite level 2 package length (in) Width (in) Height (in) Weather protective package weight (lbs) QuietSite level 1 package weight (lbs) QuietSite level 2 package weight (lbs) 270 188 188 222 82 106 4991 5471 6711 300 188 188 222 82 104 5648 6073 6991 400 188 188 222 82 106 5833 6258 7176 500 188 188 222 82 108 5956 6381 7299 600 188 188 222 82 111 6116 6541 7459 660 188 188 222 82 113 6235 6660 7578 720 188 188 222 82 114 6174 6599 7517 850 188 188 222 82 118 6529 6954 7872 1420 200 200 222 82 128 6863 7343 8583 1470 192 192 222 82 128 7253 7733 8973 1700 234 234 234 82 128 7982 8407 9325 2050 284 284 284 82 128 8383 8863 10103 2525 346 346 346 82 128 9391 9871 11111 Lifting base 188 188 222 82 100 4335 4760 5678 600-1000 kW Tank size (gal) Weather Protectiv e package length (in) QuietSite level I package length (in) QuietSite level 2 package length (in) Width (in) Height (in) Weather protective package weight (lbs) QuietSite level 1 package weight (lbs) QuietSite level 2 package weight (lbs) 200 260 303 315 98 137 10194 13074 14954 660 260 303 315 98 137 9586 12466 14346 1000 260 303 315 98 141 10117 12997 14877 1500 260 303 315 98 146 10677 13557 15437 2000 292 327 327 98 143 11959 14839 16719 2400 338 338 338 98 143 12961 15841 17721 - This weight does not include the generator set. Consult your local Cummins Power Generation distributor or the appropriate g enerator specification sheet. - Width is 86” lifting eye to lifting eye (250-500 kW), 102” lifting eye to lifting eye (600-1000 kW). - Height - Florida, Michigan, and Suffolk add 6.4” (250-500 kW) or 2” (600-1000 kW) for bottom space. - Maximum length emergency vent removed. . Our energy working for you.™ www.cumminspower.com 2014 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Specifications are subject to change without notice. S-1443Y (A037S884) (12/16) CSA - The generator set is CSA certified to product class 4215-01. UL - The generator set is available Listed to UL 2200, Stationary Engine Generator Assemblies. The PowerCommand control is Listed to UL 508 - Category NITW7 for U.S. and Canadian usage. See your distributor for more information Americas 1400 73rd Avenue N.E. Minneapolis, MN 55432 USA Phone: 763 574-5000 Fax: 763 574-5298