Loading...
HomeMy WebLinkAboutAH Summary 10-26-2017OFFICE OF COMMUNITY DEVELOPMENT CITY HALL 10300 TORRE AVENUE < CUPERTINO., CA 95014-3255 (408) 777-3308 o FAX (408) 777-3333. planning@cupertino.org To: Mayor and City Council Members Planning Commissioners From: Benjamin Fu, Assist. Director of Community Development Date: October 30, 2017 Subj: REPORT OF ADMINISTRATIVE HEARING DECISION MADE October 26, 2017 Chapter 19.12.170 of the Cupertino Municipal code provides for Avveal' of decisions made at an Administrativehearing 1. Application ASA -2017-05, TR -2017-39, Whitney Marr (C&L Investments, LLC), 21020 Homestead Rd Description Major Architectural and Site Approval to allow for the demolition of an existing single -story 6,000 square feet multi -tenant commercial building and to allow for the construction of a new single -story 4,178 square feet Bank of America branch building and ancillary parking lot improvements, landscaping, and frontage and street improvements including a paved plaza area at the intersection of Homestead and North Stelling Roads; Tree Removal Permit to allow the removal and replacement of fourteen protected trees Action The application was approved at the Administrative Hearing. The approval is effective October 26, 2017. The fourteen -calendar day appeal will expire on November 9, 2017. Enclosures: Administrative Hearing Report of October 26, 2017 Resolution No(s) 82 & 83 Plan set CUPERTINO SUBJECT OFFICE OF COMMUNITY DEVELOPMENT PLANNING DIVISION CITY HALL 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3308 • FAX (408) 777-3333 ADMINISTRATIVE HEARING STAFF REPORT Agenda Date: October 26, 2017 Architectural and Site Approval to consider the construction of a new 4,172 square feet Bank of America branch building to replace an existing 5,265 square feet multi -tenant commercial building, including associated site and street frontage improvements including a paved plaza area at the northeast corner of the site and a Tree Removal Permit to allow for the removal of 14 protected trees; (Application No(s).: ASA -2017-05 and TR - 2017 -39; Applicant(s): Whitney Marr (Gensler); Location: 21020 Homestead Road; APN(s): 326-07-020) RECOMMENDED ACTION That the Hearing Officer: 1. Find that the proposed actions are exempt from CEQA; and 2. Adopt the resolutions to approve the Architectural and Site Approval and Tree Removal permits in accordance with the draft resolutions (Attachments 1 and 2). DISCUSSION Project Data: General Plan Designation:' Commercial Special Area: Stelling Gateway in the Homestead Special Area Zoning Designation: P(CG) Planned Development (General Commercial) Existing Proposed Lot Size: 25,422 sq. ft. 24,163 sq. ft. (1,259 sq. ft. dedicated to the City) Floor Area and Use: 5,265 sq. ft. multi -tenant commercial building 4,172 sq. ft. bank branch ASA -2017-05 21020 Homestead Road (Bank of America) October 26, 2017 TR -2017-39 Page 2 Setbacks Required Proposed Front: Based on GP policies and adequate for light, air and visibility. GP requires a 1:1 height to setback ratio from curb on Homestead Rd. 22'-6" Street Side: None required 25' Interior Side: None required 50' Rear: None required 74' Parking Auto Parking: 17 spaces 33 spaces Bicycle Parking: 4 spaces 4 spaces Maximum Proposed Height: 30' 22' Project Consistency with General Plan: Yes Zonin : Yes Environmental Assessment: Categorically Exempt per Section 15302, Class 2 (Replacement or Reconstruction) of California Quality Act (CEQA) Background: Site Description The project site is located within the Homestead Special Area in the Stelling Gateway on the southwest corner of Homestead and N. Stelling Roads. The Stelling Gateway is located close to city limits, with the City of Sunnyvale located on the north side of Homestead Road and the City of Cupertino on the south. The land uses surrounding the intersection are mainly commercial and retail uses in both jurisdictions with the closest residences to the subject property more than 300 feet to the northeast. The Homestead Special Area, which extends from N. Blaney Ave. on the east to Noranda Dr. (west of N. Stelling Rd.) on the west, is intended to continue as a predominantly mixed-use area with residential uses and neighborhood centers providing services to local residents. The property is bounded on the west and to the south by the lands of Valley Church of Santa Clara County; to the north by a ASA -2017-05 21020 Homestead Road (Bank of America) October 26, 2017 TR -2017-39 Page 3 commercial center located in the City of Sunnyvale, with an Orchard Supply Hardware, CVS Pharmacy, Taco Bell and several restaurant and retail tenants; to the northeast by a SpeeDee Oil Change and Auto Service building; and to the east by a commercial center with several restaurant tenants, a McDonald's restaurant, and a bowling alley (Homestead Lanes). Most of the properties surrounding the subject site are developed with single story buildings. The site currently has a single -story multi -tenant commercial building constructed in 1980 with three tenants: a beauty salon, a massage therapy office, and a chiropractor office. Application Requests The applicant is seeking to construct a new Bank of America branch building to replace the existing building on the site. The proposed use is a permitted use in this zoning district, therefore no Conditional Use Permit is required. However, an Architectural and Site Approval permit is required in order to approve the architecture and associated site improvements, including re -pavement of the parking lot, re -landscaping at the site, construction of a plaza at the northeast corner of the property, and a new trash enclosure to service the center. The improvements include the removal of 14 existing protected trees for which a Tree Removal permit is required. The application also includes a comprehensive site -wide tree replacement plan in conjunction with the proposed new building, landscaping, and off-site improvements. While the Tree Removal Permit may be approved by the Director of Community Development without a public meeting, the zoning code requires review by the highest approval authority when applications are combined. Therefore, the permit must be reviewed concurrently with the Architectural and Site Approval permit at an Administrative Hearing. Signage is not approved as part of this proposal. Therefore, any future signs must be approved through a sign permit or a Master Sign Program. Additionally, the property is located in a zone where all fencing must be reviewed and approved by the City prior to installation. Therefore, any existing unpermitted fencing will be required to be removed and any new proposal for fences will need additional staff review. Analysis: The applicant team has worked extensively with staff to address policies in General Plan: Community Vision 2015-2040 such as site planning, building and parking location, building layout, street interfaces, reduced driveway openings, shared and consolidated driveway access, sidewalk and street frontage landscaping, pedestrian -oriented public spaces, and public art. ASA -2017-05 21020 Homestead Road (Bank of America) TR -2017-39 Site Planning and Architectural Design October 26, 2017 Paize 4 The proposal maintains the general building location and parking lot configuration as it currently exists, with the building located at the northeast portion of the property, and the parking located at the rear of the building. The proposal locates the business entrance close to the street to enhance the street interface and to provide a safe entry point for pedestrians accessing the building from the public sidewalks. Pedestrian activity is promoted at the site by maximizing window openings along both street frontages and placing a plaza at the corner of the parcel (further described below). Additionally, special paving leading up to the bank from the parking lot also helps to improve pedestrian experience and access from the primary parking lot. The building is proposed with smooth stucco finish throughout, aluminum metal paneled canopy over select areas, and clear windows spanning the northern and eastern elevations where offices and entrances are located. The southern and western portions of the building, where the back -of -office facilities are located, face the L-shaped parking lot. Since these walls are largely void of any fenestrations, lattices and vine landscaping have been added at the city's consultant architect's recommendation. The proposed automatic teller machines (ATM) are located within a card -protected 24- hour vestibule located at the southeast portion of the building and visible from N. Stelling Road. The lighting for areas around ATMs are required by the Cupertino Municipal Code to be in conformance with the minimum standards required by the State of California Business and Professions Code and will be further reviewed prior to issuance of building permits. Plaza The Cupertino General Plan sets goals to promote public spaces that enhance community identity and character (Policy LU -2.2: Pedestrian -Oriented Public Spaces) and developments are required to incorporate pedestrian -scaled elements along the street to meet such goals. While the architectural consultant recommended that the employee area located at the southwest corner of the building include additional design elements for more usability and higher visual quality and serve as a gathering spot, no changes have been made in this area due to the bank's need to maintain the area clear of any visual obstructions or barriers to address security concerns. The provision of the plaza at the northeast corner as the public side/face of the site is an acceptable alternative. The proposed plaza serves as an enhanced public amenity and is designed with ground -level decorative pavers and concrete seat -walls with precast stone veneers, but has limited landscaping. The architectural consultant recommends adding tall shade trees at the corner similar to those on the SpeeDee site in the City of Sunnyvale and adding a public art piece. No ASA -2017-05 21020 Homestead Road (Bank of America) October 26, 2017 TR -2017-39 Pa Lye 5 public art piece has been proposed by Bank of America since it appears that previous issues with controversial art has led to a corporate policy that limits the ability to include art pieces such as, murals or sculptures. Additionally, no changes were made to the plans to add shade trees at the plaza. A condition of approval has been added to require the planting of a medium-sized shade tree to the satisfaction of the City in consultation with the City's consulting arborist and the integration of small landscape areas closest to the right of way and/or planter pots within the plaza area. Landscaping & Trees As part of the on-site improvements, the proposal includes removal of 14 existing development (protected) trees that were determined to be unsuitable for retention due to decline in health, poor horticultural care and maintenance practices, conflict with proposed street improvements, and species incompatibility with newly proposed storm water infiltration areas. In order to mitigate the removal of the trees, the applicant team proposes to plant five Red Maples (Acer rubrum), two Zelkovas (Zelkova serrulata), and nine Crape Myrtles (Lagerstroemia spp.). The replacement trees are dispersed throughout the site: within the newly proposed water infiltration areas adjacent to parking, along the front and street side setbacks along the street frontages and in the plaza area as conceptualized in the landscape plan (Attachment 3). While the tree replacements will increase the limited existing canopy coverage, the proposed species will need to be evaluated as sufficient shade trees in conformance with General Plan policies (Strategies ES -2.1.5: Urban Forest and ES -5.1.2: Built Environment). The conditions of approval regarding landscaping include provisions to ensure that the final landscape plan indicate additional ground cover in the area adjacent to the intersection where paving is proposed and that the final species of replacement trees be reviewed and approved by the City in consultation with the City's Consulting Arborist prior to issuance of building permits. Parking and Circulation The development provides 33 parking spaces (16 auto parking spaces more than required) and 4 bicycle parking spaces in compliance with the City's Parking Ordinance. As mentioned previously, the parking is located at the rear of the building to ensure that driveway approaches are spaced appropriately away from the intersection as well as to promote active street frontages. Furthermore, the bicycle parking is conveniently located at the entrance of the bank building facing and adjacent to North Stelling Road, where a Class IV separated bike lane is envisioned in the Cupertino Bicycle Transportation Plan. There are two driveways located within 50 feet of each other on Homestead Rd, one serving the subject site and one serving the adjacent property (Valley Church). The Cupertino General Plan sets a goal of improving walkability and bikeability and, to that ASA -2017-05 21020 Homestead Road (Bank of America) October 26, 2017 TR -2017-39 Page 6 end, identifies policies to further this goal. One of the qq,i� AMM W policies, Policy M-3.5: Curb Cuts states "Minimize the number and the width of driveway openings" and also encourages the shared use of driveways where feasible and — authorizes driveway closures, consolidations or both when lµ�, a site is redeveloped or remodeled (Strategy M-3.5.1: Shared,: Driveway Access).The proposal was reviewed for conformance with these policies and strategies and it was determined that the two driveways should be consolidated to improve safety and walkability. SHARED DRIVEWAY CONCEPT The applicant is agreeable to working with the property – owners of Valley Church to reduce the number of driveway cuts along Homestead by consolidating the existing driveways (indicated in red in Shared Driveway Concept) and utilizing shared driveway access. Discussions were initiated for pursuing the driveway consolidation and during preliminary discussions, it was determined that the shared driveway would lie where currently there is a PG&E electric junction box, and fiber optic lines and meters. Due to the anticipated time that would be required to engage with and receive approvals with the appropriate utility providers, it was agreed that consolidation for the driveway on Homestead Road could be deferred to a later time and would not need to be included in this scope of work. However, it was agreed that in the interim, the applicant would reduce the width of the driveway off of Homestead Road to 24 feet for a safer pedestrian and bicycle street interface. This has been indicated on the proposed plans. A condition of approval has been added that if the applicant is unable to obtain a building permit to implement the shared driveway prior to final occupancy, a covenant shall be recorded instead, to memorialize the agreement to consolidate the western driveway and to record appropriate ingress/egress easements for access, at a time when the City can require the same of the adjacent property. Street Improvements Off-site improvements consisting of sidewalk, curb, and driveway (discussed above) work will be required with this project. Currently, a monolithic sidewalk is located along the property's street frontages but as part of off-site improvements it will be replaced with a detached sidewalk to the satisfaction of the Director of Public Works. Furthermore, the pedestrian curb ramp at the intersection of Homestead and N. Stelling Roads will be reconfigured and a traffic signal pole will be relocated. In addition, a dedication of land of up to 10 feet in width along the project frontage, to the satisfaction of the Director of Public Works, is required. ASA -2017-05 TR -2017-39 Environmental Review 21020 Homestead Road (Bank of America) October 26, 2017 Paye 7 This project is categorically exempt from the requirements of the California Environmental Quality Act (CEQA) per Section 15302 — Replacement or Reconstruction because the exemption applies to the replacement or reconstruction of existing structures and facilities where the new commercial structure will be located on the same site as the structure replaced and will have substantially the same size, purpose, and capacity as the structure replaced. Other Department/Agency Review The City's Public Works Department; Building Division; Environmental Programs Division; the Santa Clara County Fire Department; Cupertino Sanitary District; and Recology reviewed the request and have no objections to the project. Their pre -hearing comments have been incorporated as conditions of approval in the draft resolutions. PUBLIC NOTICING AND COMMUNITY OUTREACH The following table is a brief summary of the noticing for this project: Notice of Public Hearing A enda ■ Site Signage (at least 14 days prior to ■ Posted on the City's official notice hearing) bulletin board (five days prior to ■ 8 notices mailed to property owners hearing) adjacent to the project site (at least 10 days ■ Posted on the City of Cupertino's prior to the hearing) Web site ve days prior to hearing) As of October 19, 2017, staff has received comments from four people. Written public comments are included as Attachment 4. Two people stated that they were opposed to the proposed development as they were patrons of Happy Cuts which they wished to remain at the site. A member of the public shared their confusion on the necessity of another bank branch particularly when replacing an existing fully -tenanted commercial building that provides the community with personal services and felt a bank branch would be better located in an area that can be easily accessed by foot like a shopping mall. Furthermore, they shared concerns with regard to the tree removal and proposed landscaping plans. Another member of the public verbally expressed concerns about the traffic impact of additional construction on Homestead Road stating that it is very inconvenient for the community and that left turns out of the development are dangerous. ASA -2017-05 21020 Homestead Road (Bank of America) October 26, 2017 TR -2017-39 Page 8 PERMIT STREAMLINING ACT This project is subject to the Permit Streamlining Act (Government Code Section 65920 — 65964). The City has complied with the deadlines found in the Permit Streamlining Act. Project Received: May 26, 2017; Deemed Incomplete: June 26, 2017 Revisions Received: August 31, 2017; Deemed Incomplete: September 28, 2017 Revisions Received: October 11, 2017; Deemed Complete: October 11, 2017 Since this project is Categorically Exempt, the City has 60 days (until December 11, 2017) to make a decision on the project. CONCLUSION Staff recommends approval of the Architectural and Site Approval and Tree Removal Permits, since the plans and conditions of approval address all concerns related to the proposed project. Additionally, all of the findings for approval of the proposed project, consistent with Chapters 14.18 and 19.168 of the Cupertino Municipal Code, may be made as reflected in the Draft Resolutions. NEXT STEPS The permit will be effective 14 calendar days from the date of the hearing. The decision of the Administrative Hearing Officer is final, unless appealed within 14 calendar days from the date of the hearing. The applicant team may apply for building and/or other permits with the City at the end of the appeal period. This approval is valid until October 26, 2019. The applicant team may apply for a one- time one year extension before the approval expires. Prepared by: Ellen Yau, Assistant Planner Approved by: Piu Ghosh, Principal Planner ATTACHMENTS 1. Draft Resolution for ASA -2017-05 2. Draft Resolution for TR -2017-39 3. Plan Set 4. Written Public Comments CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 RESOLUTION NO. 82 OF THE ADMINISTRATIVE HEARING MEETING OF THE CITY OF CUPERTINO .....--- ---- - ..._- -- - --- TO CONSIDER THE CONSTRUCTION OF A NEW 4,172 SQUARE FEET BANK OF AMERICA BRANCH BUILDING TO REPLACE AN EXISTING SINGLE -STORY 5,265 SQUARE FEET MULTI -TENANT COMMERCIAL BUILDING, INCLUDING ASSOCIATED SITE AND STREET FRONTAGE IMPROVEMENTS INCLUDING A PAVED PLAZA AREA AT THE NORTHEAST CORNER OF THE SITE AT 21020 HOMESTEAD ROAD. SECTION I: PROTECT DESCRIPTION Application No.: ASA -2017-05 Applicant: Whitney Marr (C&L Investments, LLC) Location: 21020 Homestead Road APN #326-07-020 SECTION II: FINDINGS WHEREAS, the Administrative Hearing Meeting of the City of Cupertino received an application for a new 4,172 square feet Bank of America branch building to replace an existing single -story 5,265 square feet multi -tenant commercial building, including associated site and street improvements, including a paved plaza area at the northeast corner of the site; and WHEREAS, the projects is categorically exempt from the California Environmental Quality Act (CEQA); WHEREAS, the necessary public notices have been given as required by the Procedural Ordinance of the City of Cupertnlo, and the Administrative Hearing Officer has held at least one public meeting �inregard to the application; WHEREAS, the appli application; and has met the burden of proof required to support said WHEREAS, the Administrative Hearing Officer finds: Resolution No. 82 ASA -2017-05 October 26, 2017 Page 2 1. The proposal, at the proposed location, will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience; The proposal maintains the general building location and parking lot configuration as it currently exists, with the building located at the northeast portion of the property, and the parking located at the rear of the building. The project proposal will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience. The project would be required to detach the existing monolithic sidewalk along the property's street fton This would improve the pedestrian experience and safety. The proposal also includes mitigations to reduce the width of existing two-way driveway curb cuts which would further enhance the site and ameliorate impacts to pedestrians and bicyclists. 2. The proposal is consistent with the purposes of Chapter 19.168, Architectural and Site Review, of the Cupertino Municipal Code, the General Plan, any specific plan, zoning ordinances, applicable planned development permit, conditional use permits, variances, subdivision maps or other entitlements to use which regulate the subject property including, but not limited to, adherence to the following specific criteria: a) Abrupt changes in building scale should be avoided. A gradual transition related to height and bulk should be achieved between new and existing buildings; Most of the properties surrounding the subject site are developed with single story buildings and the proposed building maintains the single -story scale and increases to the height of the building are primarily to incorporate parapets in order to screen anticipated rooftop equipment. Additionally, the mass of the building is accentuated with a combination of wall articulation, decorative cornices, metal awnings, and significant window fenestration. Furthermore, the proposed changes to the height of the structure are within the regulations established in the General Plan: Community Vision 2015-2040. b) In order to preserve design harmony between new and existing buildings and in order to preserve and enhance property values, the materials, textures and colors of new buildings should harmonize with adjacent development by being consistent or compatible with design and color schemes, and, with the future character of the neighborhood and purposes of the zone in which they are situated. The location, height and materials of walls, fencing, hedges and screen planting should harmonize with adjacent development. Unsightly storage areas, utility installations and unsightly elements of parking lots should be concealed. The planting of ground cover or various types of pavements should be used to prevent dust and erosion, and the Resolution No. 82 ASA -2017-05 October 26, 2017 Page 3 unnecessary destruction of existing healthy trees should be avoided. Lighting for development should be adequate to meet safety requirements as specified by the engineering and building departments, and provide shielding to prevent spill-over light to adjoining property owners; The newly proposed architectural design, materials, finishes, and textures will be consistently applied to the entire building facade to allow for four-sided complete architectural integrity - - - acid --will- be -compatible'.with -the character of - the - neighborhood as -a mix of -commercial and - - residential -scaled design. The proposal includes no changes to the location, height, and materials of walls and fencing. Any unpermitted fencing will he removed as part of this development. Landscaping is being proposed to soften the edges of the development., to enhance on-site amenities, provide relief on building walls, and are intended to harmonize with adjacent property through the installation of adequate amounts of groundcover and shade trees throughout. Furthermore, the proposal includes the construction of a trash enclosure at the rear of the parking lot which will conform to the City's requirements to screen and shelter waste collection bins. c) The number, location, color, size, height, lighting and landscaping of outdoor advertising signs and structures shall minimize traffic hazards and shall positively affect the general appearance of the <neighborhood and harmonize with adjacent development; and No signage is approved as part of this proposal.. d) With respect to new projects within existing residential neighborhoods, new development should be designed to protect residents from noise, traffic, light and visually intrusive effects by use of buffering, setbacks, landscaping, walls and other appropriate design measures The proposal is a new development that maintains the general scale, building location, and parking lot configuration as it currently exists. This development is not within all existing residential neighborhood. Therefore, this finding does not apply. However, the proposed landscaping and tree plantings aground the parking lot, street f ontages, and in the public plaza will provide visual buffering of the buildings and will enhance the tree canopy coverage on-site, and protect the closest residents, that are located 300 feet northeast of the subject site, f om visually intrusive effects. NOW, THEREFORE, BE IT RESOLVED: That after careful consideration of maps, facts, exhibits, testimony and other evidence submitted in this matter, Ithe Application No. ASA -2017-05, is hereby approved; and Resolution No. 82 ASA -2017-05 October 26, 2017 Page 4 That the subconclusions upon which the findings and conditions specified in this Resolution are based and contained in the public meeting record concerning Application No. ASA -2017-05 as set forth in the Minutes of the Administrative Hearing Meeting of October 26, 2017, and are incorporated by reference herein. SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPARTMENT 1. APPROVED EXHIBITS Approval is based on the plan set titled "Bank of America Homestead Road New Store" dated 10/18/17 drawn by Gensler consisting of eleven (11) sheets labeled "A00.50, A00.51, A00.52, A00.53, A09.11, A09.15, L.01, L.02, E-0.0, Sheet 1 of 1, and C.1, except as may be amended by conditions in this resolution. 2. CONCURRENT APPROVAL CONDITIONS The conditions of approval contained in file no. TR -2017-39 shall be applicable to this approval. 3. ANNOTATION OF THE CONDITIONS OF APPROVAL The conditions of approval set forth shall be incorporated into and annotated on the building plans. 4. ACCURACY OF PROTECT PLANS The applicant/property owner is responsible to verify all pertinent property data including but not limited to property boundary locations, building setbacks, property size, building square footage, any relevant easements and/or construction records. Any misrepresentation of any property data may invalidate this approval and may require additional review. 5. REQUIRED TRAFFIC SIGNAGE The property owner will be required to install and maintain a "No Right Turn" sign for the N. Stelling Road driveway. The sign must be located on private property. The final location and content of the sign will be reviewed by the City's Traffic Engineer prior to building permit issuance. 6. DEMOLITION REQUIREMENTS All demolished building and site materials shall be recycled to the maximum extent feasible, in accordance with the City's Recycling and Diversion of Construction and Demolition Waste under Chapter 16.72 of the Cupertino Municipal Code. The Resolution No. 82 ASA -2017-05 October 26, 2017 Page 5 applicant' shall provide evidence that materials were recycled prior to issuance of final demolition permits. 7. LIGHTING On-site lighting must be in conformance with Cupertino Municipal Code Chapter 19.60 and automatic teller machine lighting, specifically, shall meet minimum standards required by the State of California Business and Professions Code. 8. GREENSCREENS The applicant will be required to install and maintain the green screens along the western and southern walls as indicated on pages A09.11, L0.1 and L0.2 of the approved exhibits. 9. FENCING The applicant will be required to remove all unpermitted fencing to the satisfaction of the Director of Community Development prior to issuance of building permits. 10. ARBORIST REVIEW Prior to building permit issuance, an arborist review will be required as listed in the conditions of approval contained in file no. TR -2017-39. 11. LANDSCAPE DOCUMENTATION PACKAGE Prior to issuance of building permits, the applicant shall submit a full Landscape Documentation Package, per sections 14.15.050 A, B, C, and D of the Landscape Ordinance. The Landscape Documentation Package shall be reviewed and approved to the satisfaction of the Director of Community Development prior to issuance of building permits, and additional requirements, per sections 14.15.050 E, F, G, H,_ aild I will be required to be reviewed and approved prior to final inspections. i 12. LANDSCAPE AND IRRIGATION PLANS The applicant shall submit detailed landscape and irrigation plans to be reviewed and approved by the Directors of Community Development and Public Works or his/her designee prior to issuance of building permits. The landscape plan shall include water conservation and pesticide reduction measures in conformance with Chapter 14.15, Landscape Ordinance, and the pesticide control measures referenced in Chapter 9.18, Stormwater Pollution Prevention and Watershed Protection, of the Cupertino Municipal Code and shall also be amended to ensure that: a. Additional landscaping in the area closest to the right of way is incorporated through ground -level landscaping and/or in. appropriately sized planter pots within the plaza area. The landscape planter box, fencing, landscaping, irrigation Resolution No. 82 ASA -2017-05 October 26, 2017 Page 6 and/or plaza area design shall be reviewed and approved by the Director of Community Development prior to issuance of building permits; and b. A medium sized shade tree is planted at the plaza area subject to review and approval by the City in consultation with the City's Consulting Arborist; and c. The final list of replacement trees is approved by the City in consultation with the city's consulting arborist to reduce the number of crape myrtle trees proposed as replacement trees. 13. LANDSCAPE AND IRRIGATION MAINTENANCE Per the Landscape Ordinance (CMC, Chapter 14.15), a maintenance schedule shall be established and submitted to the Director of Community Development or his/her designee, either with the landscape application package, with the landscape installation report, or any time before the landscape installation report is submitted. a) Schedules should take into account water requirements for the plant establishment period and water requirements for established landscapes. b) Maintenance shall include, but not be limited to the following: routine inspection; pressure testing, adjustment and repair of the irrigation system; aerating and de -thatching turf areas; replenishing mulch; fertilizing; pruning; replanting of failed plants; weeding; pest control; and removing obstructions to emission devices. c) Failed plants shall be replaced with the same or functionally equivalent plants that may be size -adjusted as appropriate for the stage of growth of the overall installation. Failing plants shall either be replaced or be revived through appropriate adjustments in water, nutrients, pest control or other factors as recommended by a landscaping professional. 14. LANDSCAPE AND IRRIGATION INSTALLATION REPORT The project is subject to all provisions delineated in the Landscape Ordinance (CMC, Chapter 14.15). A landscape installation audit shall be conducted by a certified landscape professional after the landscaping and irrigation system have been installed. The findings of the assessment shall be consolidated into a landscape installation report. The landscape installation report shall include, but is not limited to: inspection to confirm that the landscaping and irrigation system are installed as specified in the landscape and irrigation design plan, system tune-up, system test with distribution uniformity, reporting overspray or run-off that causes overland flow, and preparation of an irrigation schedule. Resolution No. 82 ASA -2017-05 October 26, 2017 Page 7 The landscape installation report shall include the following statement: "The landscape and irrigation system have been installed as specified in the landscape and irrigation design plan and complies with the criteria of the ordinance and the permit." 15. DRIVEWAY CONSOLIDATION AND INGRESS/EGRESS EASEMENT. Should__-._the...._applicant..._ not._ _obtain appro_pnate_ building. _permits. _ and._._ record appropriate easements for consolidation of the west driveway off of Homestead Road prior to issuance of building permits for the bank building, prior to final occupancy, the applicant shall record a covenant (or whichever legal, ;document deemed appropriate by the City) agreeing to consolidate the existing driveway off of Homestead Road and record an appropriate Reciprocal Access Easement over portions of the property for shared driveway access. The nonexclusive easement shall provide vehicular and pedestrian ingress and egress over the area for shared driveway access. The easement language shall provide that construction of the driveway shall be completed/connected to the City's satisfaction at such time as the city can require the adjacent property owner to. agree to consolidate the driveway and provide a reciprocal ingress/egress easement through a planning permit. The agreement language including the driveway and easement layout shall be reviewed and approved by the City prior to recordation with the County Recorder's Office. The easement shall contain a provision that it may not be modified or removed without express written approval from the City. 16. SCREENING All mechanical and other equipment on the building or on the site shall be screened so they are not visible from public street areas or adjoining developments. Screening materials/colors shall match building features and materials. The height of the screening shall be taller than the height of the mechanical equipment that it is designed to screen. The location of. equipment and necessary screening shall be reviewed and approved 17. UTILITY STRUCTURE PLAN Prior to issuance of building permits, the applicant shall work with staff to provide a detailed utility plan to demonstrate screening or undergrounding of all utility structures [including, but not limited to backflow preventers (BFP), fire department connections (FDC), post -indicator valves (PIV), and gas meters] to the satisfaction of the Director of Community Development, Public Works, Fire Department, and applicable utility agencies. Resolution No. 82 ASA -2017-05 October 26, 2017 Page 8 18. WINDOW DETAILS The frontage windows shall be kept open and transparent to the greatest extent possible. The final storefront design and window display shall be reviewed and approved by the Director of Community Development prior to issuance of building permits for tenant improvements. No changes shall be made to the transparency of the windows without the express approval of the Director of Community Development. 19. EXTERIOR BUILDING MATERIALS/TREATMENTS The final building exterior plan shall closely resemble the details shown on the original approved plans. Final building exterior treatment plan (including but not limited to details on exterior color, materials, architectural treatments, doors, windows, lighting fixtures, and/or embellishments) shall be reviewed and approved by the Director of Community Development prior to issuance of building permits to ensure quality and consistency. Any exterior changes determined to be substantial by the Director of Community Development shall either require a modification to this permit or a new permit based on the extent of the change. 20. CONSULTATION WITH OTHER DEPARTMENTS The applicant is responsible to consult with other departments and/or agencies with regard to the proposed project for additional conditions and requirements. Any misrepresentation of any submitted data may invalidate an approval by the Community Development Department. 21. NOTICE OF FEES, DEDICATIONS, RESERVATIONS OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90 -day approval period in which you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90 -day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. Resolution No. 82 ASA -2017-05 October 26, 2017 Page 9 NDITI DEPARTMENT 22. TRAFFIC IMPA BY THE PUB The Project may be subject to pay Traffic Impact Fees. The fee is currently estimated to be set at $7,000 per new AM or PM peak -hour trip generated by the Project subject to be approved by the City Council in August 2017. 23. STREET IMPROVEMENTS & DEDICATION Provide a dedication and frontage improvements along the project frontage to the satisfaction of the Director of Public Works. Street improvements may include, but not be limited to, new detached sidewalk, new ADA ramp, driveways, storm drain lateral, street tree installations, and street light and/or pedestrian push button relocation. 24. PEDESTRIAN AND BICYCLE IMPROVEMENTS Developer shall provide pedestrian and bicycle related improvements (e.g. walkway and bicycle racks, etc.) consistent with the Cupertino Bicycle Transportation Plan and the Pedestrian Transportation Guidelines, and as approved by the Director of Public Works. 25. STREET LIGHTING INSTALLATION Street lighting shall be installed and shall be as approved by the Director of Public Works. Lighting fixtures shall be positioned.so as to preclude glare and other forms of visual interference, to adjoining properties, and shall be no higher than the maximum height permitted by the zone in which the site is located. 26. GRADING AND DRAINAGE Grading shall be as 'approved and required by the Director of Public Works in accordance with Chapter 16.08 of the Cupertino Municipal Code. All storm drain inlets!, be clearly marked with the words "No Dumping — Flows to Creek" using permanently affixed metal medallions or equivalent, as approved by the Environmental Programs Division. 27. C.3 REQUIREMENTS C.3 regulated improvements are required for all projects creating and/or replacing 10,000 S.F. or more of impervious surface (collectively over the entire project site). The developer shall reserve a minimum of 4% of developable surface area for the placement of low impact development measures, for storm water treatment, unless Resolution No. 82 ASA -2017-05 October 26, 2017 Page 10 an alternative storm water treatment plan, that satisfies C.3 requirements, is approved by the Director of Public Works. The developer must include the use and maintenance of site design, source control and storm water treatment Best Management Practices (BMPs), which must be designed per approved numeric sizing criteria. A Storm Water Management Plan, Storm Water Facilities Easement Agreement, Storm Water Facilities Operation and Maintenance Agreement, and certification of ongoing operation and maintenance of treatment BMPs are each required. All storm water management plans are required to obtain certification from a City approved third party reviewer. 28. IMPROVEMENT AGREEMENT The project developer shall enter into a development agreement with the City of Cupertino providing for payment of fees, including but not limited to checking and inspection fees, storm drain fees, park dedication fees and fees for under grounding of utilities. Said agreement shall be executed prior to issuance of construction permits. Fees: a. Checking & Inspection Fees: b. Grading Permit: c. Development Maintenance Deposit: d. Storm Drainage Fee: e. Traffic Impact Fee: f. Power Cost: g. Storm Management Plan Fee: h. Street Tree: $ Per current fee schedule ($6,266.00 or 5% of improvement costs) $ Per current fee schedule ($2,825.00 or 6% of improvement costs) $1,000.00 $ Per current fee schedule ($8,790.00 per AC) $7,000 per new AM or PM peak -hour trip Per current fee schedule ($1,208) By Developer ** Based on the latest effective PG&E rate schedule approved by the PUC Bonds: - Faithful Performance Bond: 100% of Off-site and On-site Improvements - Labor & Material Bond: 100% of Off-site and On-site Improvement - On-site Grading Bond: 100% of site improvements. Resolution No. 82 ASA -2017-05 October 26, 2017 Page 11 The fees described above are imposed based upon the current fee schedule adopted by the City Council. However, the fees imposed herein may be modified at the time of recordation of a final map or issuance of a building permit in the event of said change or changes, the fees changed at that time will reflect the then current fee schedule. 29. TRASH, RECYCLYING AND COMPOST ENCLOSURES Trash enclosure plans must be designed in accordance with the City's Public Works Guidelines posted at www.cupertino.org/nowaste, and to the satisfaction of the Environmental Programs Manager. Clearance by the Public Works Department is required prior to obtaining a building permit (CMC 9.18.210 (H) & (K)). 30. OPERATIONS & MAINTENANCE AGREEMENT Developer shall enter into an Operations & Maintenance Agreement with the City prior to final occupancy. The Agreement shall include the operation and maintenance for non-standard appurtenances in the public road right-of-way that may include, but is not limited to, sidewalk, pavers, and street lights. 31. UNDERGROUND UTILITIES Developer shall comply with the requirements of the Underground Utilities Ordinance No. 331 and other related Ordinances, -and regulations of the City of Cupertino, and shall coordinate with affected utility providers for installation of underground utility devices. Developer shall submit detailed plans showing utility underground provisions. Said plans shall be subject to prior approval of the affected Utility provider and the Director of Public Works. _ I 32. TRANSFORMERS New electrical transformers, telephone cabinets and similar equipment shall be placed in underground vaults. The developer must receive written approval from both the Public Works Department and the Community Development Department prior to installation of any above ground equipment. Should above ground equipment be permitted by the City, equipment and enclosures shall be screened with fencing and landscaping such that said equipment is not visible from public street areas, as determined by the Community Development Department. Transformers shall not be located n1 the front or side building setback area. 33. WATER BACKFLOW PREVENTERS Domestic and Fire Water Backflow preventers and similar above ground equipment shall be placed away from the public right of way and site driveways to a location Resolution No. 82 ASA -2017-05 October 26, 2017 Page 12 approved by the Cupertino Planning Department, Santa Clara County Fire Department and the water company. 34. BEST MANAGEMENT PRACTICES Utilize Best Management Practices (BMPs), as required by the State Water Resources Control Board, for construction activity, which disturbs soil. BMP plans shall be included in grading and street improvement plans. 35. EROSION CONTROL PLAN Developer must provide an approved erosion control plan by a Registered Civil Engineer. This plan should include all erosion control measures used to retain materials on site. Erosion control notes shall be stated on the plans. 36. WORK SCHEDULE Every 6 months, the developer shall submit a work schedule to the City to show the timetable for all grading/erosion control work in conjunction with this project. 37. TRAFFIC CONTROL PLAN The developer must submit a traffic control plan by a Registered Traffic Engineer to be approved by the City. The plan shall include a temporary traffic control plan for work in the right of way as well as a routing plan for all vehicles used during construction. All traffic control signs must be reviewed and approved by the City prior to commencement of work. The City has adopted Manual on Uniform Traffic Control Devices (MUTCD) standards for all signage and striping work throughout the City. 38. STREET TREES Street trees shall be planted within the Public Right of Way to the satisfaction of the Director of Public Works and shall be of a type approved by the City in accordance with Ordinance No. 125. 39. FIRE PROTECTION Fire sprinklers shall be installed in any new construction to the approval of the City. 40. SANTA CLARA COUNTY FIRE DEPARTMENT A letter of clearance for the project shall be obtained from the Santa Clara County Fire Department prior to issuance of building permits. Clearance should include written approval of the location of any proposed Fire Backflow Preventers, Fire Department Connections and Fire Hydrants (typically Backflow Preventers should be located on private property adjacent to the public right of way, and fire department connections must be located within 100' of a Fire Hydrant). Resolution No. 82 ASA -2017-05 October 26, 2017 Page 13 41. FIRE HYDRANT Fire hydrants shall be located as required by the City and Santa Clara County Fire Department as needed. 42. CALIFORNIA WATER SERVICE COMPANY CLEARANCE Provide California Water Service Company approval for water connection, service capability and location and layout of water lines and backflow preventers before _ _ issuance of a building permit approval. 43. DEDICATION OF UNDERGROUND WATER RIGHTS Developer shall "quit claim" to the City all rights to pump, take or otherwise extract water from the underground basin or any underground strata in the Santa Clara Valley. 44. SANITARY DISTRICT A letter of clearance for the project shall be obtained from the Cupertino Sanitary District prior to issuance of building permits. 45. UTILITY EASEMENTS Clearance approvals from the agencieswith easements on the property (including PG&E; AT&T, and California Water Company, and/or equivalent agencies) will be required prior to issuance of building permits. 46. WASTE TRIO AND CIGARETTE BUTT URN Waste trio and cigarette butt urn manufacturer specifications must be provided to the Environmental Programs Division for review. Location of waste trio must be located entirely on private property and in proximity to pedestrian use of the sidewalk. Clearance by the Public Works Department is required prior to obtaining a building permit. 47. STORM DRAINS All exterior storm drain inlets on the parcel must be fitted with full trash capture storm drain catch basin inlet devices to prevent litter from entering the storm drain system. Devices installed must be approved by the California State Water Board and selected from the San Francisco Bay Regional Water Quality Control Board list, which can be viewed at http://-�vww.sfestuary.org/approved-trash-capture-dei7ices. Please include with the resubmittal, the manufacturer specification sheet for all trash capture device(s) included with the project. As a condition of approval, the devices must be installed and maintained (cleaned)' in accordance with the manufacturer specifications, but not less than two times per year. The property owner must Resolution No. 82 ASA -2017-05 October 26, 2017 Page 14 provide official request. written record of cleaning and maintenance to the City upon 48. STORM DRAIN INLET MARKERS All exterior storm drain inlets on the property shall be clearly marked with "No Dumping Flows to Creek" or "No Dumping Flows to Bay" markers. 49. COPPER USES PROHIBITED Copper metal roofing, copper granule containing asphalt shingles, copper gutters and downspouts, and/or other exterior ornamental copper are not permitted for use on any commercial or industrial building. 50. C&D WASTE MANAGEMENT PLAN A completed C&D Waste Management Plan must be submitted at the time of building permit issuance. If the applicant and/or their contractor and any subcontractor working on the project self -hauls the C&D material, a Waste Management Report must be submitted prior to final approval of the building permit demonstrating a minimum of 65% of the C&D waste has been diverted from landfill and recycled. Please note that C&D debris box service may only be obtained from Recology, the City's franchised waste hauler. C&D Recycling information and reports may be viewed at www.cupertino.org/greendev. 51. RECOLOGY REVIEW The location, path of travel, and associated design features of the on-site trash enclosure will be required to be reviewed by Recology, the City's franchised waste hauler, and approved by the Public Works Department prior to building permit issuance. SECTION V: CONDITIONS ADMINISTERED BY THE BUILDING DEPT. 52. ACCESSIBLE PATH OF TRAVEL The applicant shall provide accessible path -of -travel from the building to the trash enclosure per 2016 California Building Code. SECTION VI: CONDITIONS ADMINISTERED BY SANTA CLARA COUNTY FIRE r)FPT 53. FIRE SPRINKLERS Certain structures may require fire sprinkler coverage under exterior roof overhangs. Such areas must be reviewed by a properly licensed contractor. If the fire sprinkler system is to be modified, a State of California licensed (C-16) Fire Protection Contractor shall submit plans, calculations, a completed permit Resolution No. 82 ASA -2017-05 October 26, 2017 Page 15 application and appropriate fees to the Santa Clara County Fire Department for review and approval ;prior to beginning their work. i 54. CONSTRUCTION SITE FIRE SAFETY All construction sites must comply with applicable provisions of our Standard Detail and Specification SI -7 and Chapter 33 of the currently adopted edition of the California Fire Code. This must be submitted to and approved by this office prior to _ .. _ commencing any demolition/construction activities. 55. PUBLIC FIRE HYDRANT(S) REQUIRED Identify the location of the existing public fire hydrant(s). Maximum hydrant spacing shall be 500 feet, with a minimum single hydrant flow of 1,750 GPM at 20 psi, residual. Fire hydrants shall be provided along required fire apparatus access roads and adjacent public streets within 100' of the fire department connection (FDC). 56. WATER SUPPLY REQUIREMENTS Potable water supplies shall be protected from contamination caused by fire protection water supplies. It is the responsibility of the applicant and any contractors and subcontractors to contact the water purveyor supplying the site of such project, and to comply with the requirements of that purveyor. Such requirements shall be incorporated into the design of any water-based fire protection systems; and/or fire suppression water supply systems or storage containers that may be physically connected in any manner to an appliance capable of causing contamination of the potable water supply of the purveyor of record. Final approval of the system(s) under consideration will not be granted by this office until compliance with the requirements of. the water purveyor of record are documented by that purveyor as having been met by the applicant(s). 57. ADDRESS IDENTIFICATION New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall be a minimum of 4 inches (101.6 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Resolution No. 82 ASA -2017-05 October 26, 2017 Page 16 PASSED AND ADOPTED this 26th day of October, 2017 at a noticed Public Meeting of the Administrative Hearing Officer of the City of Cupertino, State of California, held by the Director of Community Development, or his or her designee, pursuant to Cupertino Municipal Code Section 19.12.120. ATTEST: /s/Ellen Yau Ellen Yau Assistant Planner APPROVED: /s/Benjamin Fu Benjamin Fu Asst. Director of Community Development CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 RESOLUTION NO. 83 -- ._ --1- - - - -..I . .............. -- --- I_ ---------------- -- _1 --------- ------ -- OF THE ADMINISTRATIVE HEARING MEETING OF THE CITY OF CUPERTINO TO ALLOW THE REMOVAL AND REPLACEMENT OF 14 PROTECTED TREES TO FACILITATE THE CONSTRUCTION OF A NEW COMMERCIAL BANK BRANCH AND ASSOCIATED SIDEWALK IMPROVEMENTS AT 21020 HOMESTEAD', ROAD (APN 326-07-020) SECTION I: PROTECT DESCRIPTION Application No.: TR -2017-39 Applicant: Whitney Marr (C&L Investments, LLC) Location: 21020 Homestead Road -APN# 326-07=020 SECTION II: FINDINGS WHEREAS, the Administrative Hearing Officer of the City of Cupertino received an application for a Tree Removal Permit as described in Section I of this Resolution; and WHEREAS, the project is categorically exempt from the California Environmental Quality Act (CEQA); and WHEREAS, the necessary public notices have been given as required by the Procedural Ordinance of the City of Cupertino, and the Administrative Hearing Officer has held at least one public meeting in regard to the application; and WHEREAS, the applicant has met the burden of proof required to support said application; and WHEREAS, the Administrative Hearing Officer finds: 1. That the tree or trees are irreversibly diseased, are in danger of falling, can cause potential damage to, existing or proposed essential structures, or interferes with Resolution No. 83 TR -2017-39 October 26, 2017 Page 2 private on-site utility services and cannot be controlled or remedied through reasonable relocation or modification of the structure or utility services; The on-site trees were evaluated for their health and their retention suitability and in most cases the health of the tree determined their suitability for retention. No trees were determined to be in good health and have good structural stability. Of the 14 proposed removals, only three trees were evaluated with an above average health rating. These three Mexican fan palms (Washingtonia robusta,) unfortunately were rated with a poor retention suitability as the palms are located where the required stormwater control facilities are proposed and the species is typically not designed to thrive in these areas. The other protected trees evaluated were determined to be declining in health and/or have structural defects that cannot be abated with treatment and would require significant management that may still yield a limited lifespan. NOW, THEREFORE, BE IT RESOLVED: That after careful consideration of maps, facts, exhibits, testimony and other evidence submitted in this matter, the Application No. TR -2017-39, is hereby approved; and That the subconclusions upon which the findings and conditions specified in this Resolution are based and contained in the public meeting record concerning Application TR -2017-39 as set forth in the Minutes of the Administrative Hearing Meeting of October 26, 2017, and are incorporated by reference herein. SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPARTMENT 1. APPROVED EXHIBITS Approval is based on the arborist report entitled, "Arborist Report, Project #5173.00," prepared by Jake Minnick of HMH (#WE -11830A), dated October 2, 2017 consisting of twelve (12) sheets inclusive of a landscape plan; except as may be amended by conditions in this resolution. 2. CONCURRENT APPROVAL CONDITIONS The conditions of approval contained in file no. ASA -2017-05 shall be applicable to this approval. 3. TREE REPLACEMENT SPECIES The applicant is required to plant, at a minimum, a medium-sized shade tree in the public plaza to the satisfaction of the City in consultation with the City's consulting arborist. Resolution No. 83 TR -2017-39 October 26, 2017 Page 3 4. TREE REPLACEMENT SIZE The applicant shall provide adequate tree replacements for trees proposed to be removed in conformance to the replacement guidelines per Cupertino Municipal Code Section 14.18.160. The size of the proposed replacement trees shall be modified as follows to be consistent with the City's Protected Tree Ordinance unless deemed infeasible by the Ciy's Consulting Arborist: __.. ....._ a. Diameter of trunk size of removed tree up to 12 inches shall be replaced with one 24 -inch box tree; b. Over 12 inches and up to 36 inches shall be replaced by two 24 -'inch box tree or one 36 -inch box tree; and c. Over 36 inches shall be replaced with one 36 -inch box tree. If it is determined that it is physically not feasible to plant the required replacements trees, the Applicant may pay in -lieu fees determined to be appropriate by the Community Development Director. 5. ARBORIST REVIEW Prior to building. permit issuance, the number, location and species of trees shall be reviewed and approved by the City in consultation with the City's Consulting Arborist. The replacement trees shall be planted prior to building permit final. The Applicant shall provide the Department of Community Development adequate documentation, including, but not limited to, photographs, receipts or invoices, to verify that replacements have been planted. The City's consulting arborist shall inspect the trees after planting and a report ascertaining the good health of the trees mentioned above shall be provided prior to issuance of final occupancy. 6. PROTECTED TREES The applicant understands that the replacement trees may not be removed without a Tree Removal Permit and that they shall be responsible for ensuring the proper maintenance and care of the trees. The applicant shall also disclose the location and species of all replacements trees on site upon sale of the property. 7. INDEMNIFICATION Except as otherwiseprohibited by law, the applicant shall indemnify and hold harmless the City, its City Council, and its officers, employees and agents (collectively, the "indemnified parties") from and against any claim, action, or proceeding brought by a third party against one or more of the indemnified parties or one or more of the indemnified parties and the applicant to attack, set aside, or Resolution No. 83 TR -2017-39 October 26, 2017 Page 4 void this Resolution or any permit or approval authorized hereby for the project, including (without limitation) reimbursing the City its actual attorneys' fees and costs incurred in defense of the litigation. The applicant shall pay such attorneys' fees and costs within 30 days following receipt of invoices from City. Such attorneys' fees and costs shall include amounts paid to counsel not otherwise employed as City staff and shall include City Attorney time and overhead costs and other City staff overhead costs and any costs directly related to the litigation reasonably incurred by City. 8. NOTICE OF FEES, DEDICATIONS, RESERVATIONS, OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90 -day approval period in which you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90 -day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. PASSED AND ADOPTED this 26th day of October, 2017 at a noticed Public Meeting of the Administrative Hearing Officer of the City of Cupertino, State of California, held by the Director of Community Development, or his or her designee, pursuant to Cupertino Municipal Code Section 19.12.120. ATTEST: /s/Ellen Yau Ellen Yau Assistant Planner APPROVED: /s/Benjamin Fu Benjamin Fu Asst. Director of Community Development Date: October 2, 2017 Project # 5173.00 PROJECT Bank of America 21020 Homestead Road Cupertino, CA 95014 PREPARED FOR Gensler 2101 Webster Street, #2000 Oakland, CA 94612 PREPARED BY HMH 1570 Oakland Road San Jose, CA 95131 Jake Minnick ISA Certified Arborist WE -11830A Application Number Aly DC�'j-1--too -"Ir DaYQ lgnatur Case Marlag" yI TAT BLE OF CONTENITS Introduction and Overview Methodology Summary of Findings Planned Development Recommendations Terms and Conditions Exhibit A - Tree Location Map Tree Evaluation Summary Exhibit B - Tree Photographs Page 2 3 4 5 8 21020 Homestead Road HMH was contracted by Gensler to complete a tree survey, assessment and arborist report for the entire site located at 21020 Homestead Road in Cupertino, California. The site consists of one retail office building bounded on two sides by double loaded parking, and the other two sides by Homestead Road to the north and N Stelling Road to the east. Our scope of services includes measuring diameter at breast height, assessing, and photographing the condition of all trees on site. Disposition and health recommendations are based on current site conditions. Site development/design may affect the preservation suitability. Our tree survey work is a deliberate and systematic methodology for cataloging trees on site: 1. Identify each tree species. 2. Note each trees location on a map. 3. Measure each trunk circumference at 54" above grade per ISA standards. 4. Evaluate the health and structure of each tree using the following numerical standard: 5 - A healthy, vigorous tree, reasonably free of disease, with good structure and form typical of the species. 4 - A tree with slight decline in vigor, small amount of twig dieback, minor structural defects that could be corrected. 3 - A tree with moderate vigor, moderate twig and small branch dieback, thinning of crown, poor leaf color, moderate structural defects that may that might be mitigated with care. 2 - A tree in decline, epicormic growth, extensive dieback of medium to large branches, significant structural defects that cannot be abated. 1 - A tree in severe decline, dieback of scaffold branches and or trunk, mostly epicormic growth, extensive structural defects that cannot be abated. 0 - Tree is dead. All trees located on the parcel of 21020 Homestead Road along with any trees within 10' of the property line are included in this tree inventory. Generally, all dichotomous trees inventoried showed indications of poor horticultural practices related specifically to care and maintenance practices. A majority of the ash trees showed signs of mechanical damage from the use of tree climbing spurs for tree pruning. As a typical best management practice by recommendation of the International Society of Arboriculture, tree climbing spurs shall only be used in the removal of dead trees or in emergency rescue situations due to the damage that can be inflicted to the tree bark and sapwood. Additionally, many of the trees onsite appear to be over pruned as evidenced by the presence of epicormic growth along the lower scaffold limbs and trunks along with irregularly shaped canopies, and/or extensive suckering at the base of the tree. Several trees are located within very close proximity to the chain-link fence and large shrubs along the southern property line. These trees are severely crowded and stressed by the fence and in some cases, large neighboring shrubs. Without removal of the objects that are crowding these trees it is likely that they will continue to decline. No specimen or heritage trees were observed. 5173.00 HMH 408.487.2200 1 October 2, 2017 21020 Homestead Road The trees located on the project site are not viable specimens for preservation for the following reasons: Mexican fan palm: The Mexican fan palms located on this site are likely volunteers, meaning they were likely sowed from seed that was dropped from a nearby specimen or bird — not planted intentionally. This species of palm is not native to the area, but has naturalized and become quite invasive throughout California in dry regions below 1000' in elevation, making it a typically undesirable specimen for preservation. Preservation of the Mexican fan palms may be problematic on this site due to the locations of the specimens and the requirement for storm water to be treated and infiltrated onsite. Given the relatively small footprint of the project site, it's likely that storm water will need to be treated and infiltrated wherever possible throughout the parking lot finger islands and/or planting buffer areas where these palms are currently located. These palms are not suitable to be located in or near storm water infiltration sites due to their naturally high level of drought tolerance. Lastly, fan palms in general do not provide much in the way of amenities to the site given the small size of the canopy. I recommend replacing these palms with broadleaf trees that will provide additional shade in the parking lot to reduce the inherent heat island effect that parking lots present. Shamel ash: Shame[ ash trees grow very quickly and are shallow rooted. As the trees grow, their strong, shallow roots expand at a quick rate which can lead to cracked, uneven paving surfaces. Given the proximity of these trees to nearby flatwork, preservation is not recommended. The ash trees on this site have been poorly maintained throughout their lifetime which has led to structural deficiencies throughout the canopies. Climbing spurs have been used repeatedly to prune these specimens in the past which has removed portions of bark, damaged and exposed portions of the tree's cambium. It's poor horticultural practices like these that have weakened these trees, introduced biotic infection, and therefore reduced the overall preservation suitability. African sumac: The Rhus trees on this site were observed in various stages of decline. The typical low -branching structure of these trees can be problematic for parking lot areas where canopy clearance is mandatory. I recommend replacing these trees with a more suitable species for the area. Holly oak: This holly oak is located on the adjacent parcel just feet from the existing fence line. This specimen shows signs of stress associated with overcrowding and possible overwater during times of dormancy. It's likely that this specimen will continue to slowly decline if the nearby fence and oleander shrubs are not removed or relocated to allow the tree room to mature. 5173.00 It's recommended to replace the above specimens with regionally appropriate broadleaf selections that will provide wildlife environment, produce adequate shade for the parking lot, and live alongside proposed drought tolerant plant species with similar water needs. Properly selected HMH 408.487.2200 2 October 2, 2017 21020 Homestead Road and sized replacement trees will quickly exceed the canopy coverage of the existing specimens and replenish the urban forest. The following terms and conditions apply to all oral and written reports and correspondence pertaining to consultations, inspections and activities of HMH. 1. The scope of any report or other correspondence is limited to the trees and conditions specifically mentioned in those reports and correspondence. HMH assumes no liability for the failure of trees or parts of trees, either inspected or otherwise. HMH assumes no responsibility to report on the condition of any tree or landscape feature not specifically requested by the named client. 2. No tree described in this report was climbed, unless otherwise stated. HMH does not take responsibility for any defects, which could have only been discovered by climbing. A full root collar inspection, consisting of excavating the soil around the tree to uncover the root collar and major buttress roots was not performed unless otherwise stated. HMH does not take responsibility for any root defects, which could only have been discovered by such an inspection. 3. HMH shall not be required to provide further documentation, give testimony, be deposed, or attend court by reason of this appraisal or report unless subsequent contractual arrangements are made, including payment of additional fees for such services as described by HMH or in the schedule of fees or contract. 4. HMH guarantees no warrantee, either expressed or implied, as to the suitability of the information contained in the reports for any reason. It is the responsibility of the client to determine applicability to his/her case. 5. Any report and the values, observations and recommendations expressed therein represent the professional opinion of HMH, and the fee for services is in no manner contingent upon the reporting of a specified value nor upon any particular finding to be reported. 6. Any photographs, diagrams, graphs, sketches or other graphic material included in any report, being intended solely as visual aids, are not necessarily to scale and should not be construed as engineering reports or surveys, unless otherwise noted in the report. Any reproductions of graphic material or the work produced by other persons, is intended solely for the purpose of clarification and ease of reference. Inclusion of said information does not constitute a representation by HMH as to the sufficiency or accuracy of that information. 7. Trees can be managed, but they cannot be controlled. To live near trees is to accept some degree of risk. The only way to eliminate all risk associated with trees is to eliminate all trees. 5173.00 HMH 408.487.2200 3 October 2, 2017 21020 Homestead Road EXISTING TREE, TYPICAL HMH 408.487.2200 EXHIBIT A - TREE LOCATION MAP 21040 HOMESTEAD ROAD 9 8 7 • 6 5 ....ate _„ .. r. i mu I LIMIT OF WORK 4 5173.00 October 2017 21020 Homestead Road 5173.00 TREE EVALUATION SUMMARY Prepared By: Jake Minnick, ISA Certified Arborist #WE -11830A DBH MEASUREMENT HEIGHT: 54" Date of Evaluation: 5/22/2017 Suitability for Preservation is based on the following Good - Trees with good health and structural stability that have the potential for longevity at the site. Moderate - Trees in somewhat declining health and/or exhibits structural defects that cannot be abated with treatment. Trees will require more intense management and will have a shorter lifespan than those in the'Good' category. Poor - Trees in poor health or with significant structural defects that cannot be mitigated. Tree is expected to decline, regardless of treatment. Health Rating 5 A healthy, vigorous tree, reasonably free of disease, with good structure and form typical of the species. 4 A tree with slight decline in vigor, small amount of twig dieback, minor structural defects that could be corrected. 3 A tree with moderate vigor, moderate twig and small branch dieback, thinning of crown, poor leaf color, moderate structural defects that may that might be mitigated with care. 2 A tree in decline, epicormic growth, extensive dieback of medium to large branches, significant structural defects that cannot be abated. 1 A tree in severe decline, dieback of scaffold branches and or trunk, mostly epicormic growth; extensive structural defects that cannot be abated. 0 1 Tree is dead. Abbreviations and Definitions - CD Codominant branches Forked branches nearly the same size in diameter, arising from a common junction an lacking a normal branch union. CDB Dieback in Crown Condition where branches in the tree crown die from the tips toward the center. CR CR Tree is bounded closely by one or more of the following: structure, tree, D Decline Tree shows obvious signs of decline, which may be indicative of the presence of multiple biotic and abiotic disorders. DBH Diameter at Breast Measurement of tree diameter in inches. Measurement height varies by City and is noted above. Height EG I Epicormic Growth Watersprouting on trunk and main leaders. Typically indicative of tree stress. EH Exposed Heartwood Exposure of the tree's heartwood is typically seen as an open wound that leaves a tree more susceptible to pathogens, disease or infection. IB Included Bark Structural defect where bark is included between the branch attachment so the wood can't join. Such defect can have a higher probability of failure. LC Low crotch Multiple central leaders originating below the DBH measurement site. LN Leaning Tree Tree leaning, see notes for severity. MA Multiple Attachments More than one branch originating from same location on trunk. Indicates an area that could be predisposed to failure. PT Phototropism Tree exhibits phototropic growth habits. Reduced trunk taper, misshapen trunk and canopy growth are examples of this growth habit. S Suckers Shoot arising from the roots. SD Structural Defects Naturally or secondary conditions including cavities, poor branch attachments, cracks, or decayed wood in any part of the tree that may contribute to structural failure. SE Severe Indicates the severity of the following term. SL Slight Indicates the mildness of the following term. SR Surface Roots Roots visible at finished grade. WU Weak Union Weak union or fork in tree branching structure. All trees of any species listed in section 14.18.050 Protected Trees, Appendix B on private property that have a minimum single trunk diameter of ten inches Specimen Tree (thirty one inch circumference) or minimum multi trunk diameter of twenty inches (sixty three inch circumference) measured four and one half feet from natural grade are considered Specimen trees. HMH 408.487.2200 5 October 2, 2017 21020 Homestead Road 5173_nn HMH 408.487.2200 6 October 2, 2017 MULTI- PRESERV- TREE # BOTANICAL NAME COMMON NAME TOTAL STEM CIRCUM- SPECIMEN HEALTH ATION NOTES RECOMMENDATIONS DBH DBH FERENCE TREE SUITABIL- ITY SR EG, CD, IB, poor Allow this tree time to recover from recent Fraxinus uhdei shame) ash 23.0 72 3 Moderate horticultural practices - over over pruning before the next pruning cycle. pruned, climbing spur damage Do not use climbing spurs to ascend this on trunk tree in the future. Continue to monitor. 2 Rhus lancea African sumac 14.0 44 1 Poor EG, EH, CD, LN, SR, CDB, SE Remove S, ST, D 3 Rhus lancea African sumac 16.1 51 1 Poor EG, EH, CD, LN, SR, CDB, SE Remove S, ST, D L� Fraxinus uhdei shamel ash 24.1 -9-6-8-2— 76 3 MS, SR, LN, CD,-IBLC,-WU Moderate 6.3 CR, SL leaf spot Allow time to recover from recent over pruning before the next pruning cycle. SR, LN, MA, leaf spot, IB, 5 Fraxinus uhdei shame) ash 9.5 30 2 Moderate multiple WU, CR, located on Continue to monitor. adjacent parcel on the fence line/property line MS, LN, SE CR, located on Removal of the fence and heavily 6 Quercus ilex holly oak 10.2 5.3+4.9 32 2 Moderate adjacent parcel on the fence encroaching oleander shrubs could allow line/property line for an increased chance of preservation 7 Rhus lancea African 34.3 4.6, 12.3, 108 2 Moderate ML, poor horticultural Prune back structurally deficient, juvenile sumac 9 4 8 practices, SE EG, MA, SD, CR and mature epicormic growth along misshapen trunk sections. Typical crown cleaning and thinning coupled with the 7.5, 4, 3 Rhus lancea African sumac 40.9 8.6, 4.1, 128 2 Moderate ML, poor horticultural removal of several juvenile stems may 7.3, 3, practices, SE EG, MA, SD, CR increase these trees future preservation 6.4 1 suitability rating. 9 Washingtonia robusta Mexican fan 18.8 59 4 Poor Approximately 35' tall, recently Although these trees are currently in good palm pruned, straight trunk health, the future development and onsite storm water infiltration negatively impacts 10 Washingtonia robusta Mexican fan 21.1 66 4 Poor Approximately 15' tall, recently their preservation suitability. Palms palm pruned, straight trunk generally are not recommended for use in or adjacent to areas of onsite water Washingtonia robusta Mexican fan 20.2 63 4 Poor Approximately 30' tall, recently infiltration due to their low water palm pruned, straight trunk requirements. HMH 408.487.2200 6 October 2, 2017 PA10417:eirer. .-T•1Z.FT:' 51 7.'1 nn HMH 408.487.2200 7 October 2, 2017 MULTI- PRESERV- TREE # BOTANICAL NAME COMMON NAME TOTAL STEM CIRCUM- SPECIMEN HEALTH ATION NOTES RECOMMENDATIONS DBH DBH FERENCE TREE SUITABIL- ITY LN, SE EG, SR, CR, PT - under canopy of #12, SL leaf spot, poor horticultural 12 Fraxinus uhdei shamel ash 16.2 51 2 Moderate practices - over pruned, climbing spur damage on trunk, visible gopher activity in root zone LN, EG, SR, EH @ root crown from poorly executed root pruning, SL leaf spot, poor Allow this tree time to recover from recent 13 Frazinus uhdei 69 shamel ash 21.9 2 -Moderate horticultural practices - over over pruning before the next pruning cycle. pruned, climbing spur damage Do not use climbing spurs to ascend this on trunk, visible gopher activity tree in the future. Continue to monitor. in root zone LN, EG, SR, SL CDB, CD,EH @ root crown from poorly executed root pruning, SE leaf 14 Fraxinus uhdei shamel ash 23.8 75 2 Moderate spot, poor horticultural practices - over pruned, climbing spur damage on trunk, visible gopher activity in root zone HMH 408.487.2200 7 October 2, 2017 21020 Homestead Road HMH 408.487.2200 5173.00 October 2, 2017 21020 Homestead Road HMH 408.487.2200 E 5173.00 10 October 2, 2017 PLANT LEGEND arw. =WON'Nrmmewm. xu. eonyrrw.e.@mmmN :m:.l�ma@memylenn+v sx.imswee) .eer..mFm,m.mnm Im.mm",�.w ..wr>mme Perem�,rme An Har...p wl mruerMYe.mr.emywq. Fa. ae meam'asJ rY,YgemM �tlm�`F�mm'Nm,eMa' 4'^'. E rpemamm enm/erre.@ mYmrye�Yemrm enuym.mr.wrmmmv) NS"Irmrmi.reMe0. aeawaenee wrreetimreppi.mPmoremeee mmP />o'b+vwiae@mebnb ."ewaYesmw aaa Mrer.ewelr >�+..' Breem YxnM C �• ;a; T.rMwl.m moe JwNl.Y zn.r/e.Y@mYmN tN, w. mbemaasraum. ewmmsPmq nam mm4'mn Y0. T . � ^ - xamibry larumecnrl ,y.,jgq Ewentcmue'Fuewvr �•. � >nNl.be me.e@nwnry � ie � S �A S F� / 0.tlWaeTne J uNmnmbmsMseers ,�Lm mnrb/+s.ae@mee.b vmYruM rup0.rvmamrr ��i umrerewerr fir EPAeu •ee.mebwr.. wndrovwP � 1 ,rnrene lml'Nauvfn"Iar�exeete � MwMa�•mmK"Y'nuYm tiW ory nbSenmr FYMepec.r � �� �" �f vrr.a arae 10— }wcrwmrm0..—h..-. �� •eebegexeb mm ! rnyrmY.rro.e.m.@memory G2 -=qty mm merx�..rr.6arY. mwms Im YPux"0.•en.Yrywaeree-s ..arnv+ ntl �- z• u.m.muYw...r ! EnPnrcwamm @mY.rblum -" Pixw.u.iYu.e "`°rr.a. r...s s mmbetwemarYl �� "xr- �T wwrr.w vwmwr•w.mn.o.m.e"aem. Yh E.ry.m @,iw YBYy,.+^". Y � Faeem+"�rvtmi •noue*o'c .........r.. d���!'r:�t7�� �FwmrbsmaYemrm ' me.wowrYme,,r..")rerwma HOMESTEAD ROAD z y m Z A D O Bank ofAmerica Homestead Road New Store 21020 Homestead Road Cupertino, CA 95014 SERIAL NUMBER: CA NRSP VERSION: 2.0 BULLETIN: 2017-2 smemoo r.smm Tdl Gwelt Gensler F n�na S Orb ]iW 4wrnsMNwwe Pavement Engineering Inc. rr.eer, v�w.canme � �r puratron rmamRomuw. I+w.,o..mx.awmwmm ID . s¢vli.eor.�m PreAamvp SWnO. lei ot"elrcnm. xmarw Rotl Imrm.. IPRmMIf W 1Y IAN0.5CPPE RPN u sxovn SHEET L.01 PROGRAM INFORMATION LOCATION INFORMATION 21020 Homestead Road Corner of Homestead and N. Stelling Roads Cupertino, CA 95014 TF-DENO-GR FLAGSHIP • (7) OFFICES p • (3) ATM DAY 1 4 • (3) TELLERS W/ BR _ GLASS _ • (10) WAIT SEATING • (1) LG UCC a • (2) SM UCC (1) • (1) WU N.D. DISPOSITION OF (E) TREES All existing site trees were deemed unsalvageable due to condition and unsuitable for proposed site uses - all current site trees are planned to be removed. NOT A PART OF THIS SUBMITTAL SIGNAGE DESIGN, LAYOUT, LOCATION OR SIZE HOMESTEAD ROAD (N)CURB CUT (E) CITY STREET LIGHT I.A 24'-0'WIDE Z R.O.W. DEDICATION TO THE CITY OF M m O S89'4T00'E 129.63' Proposed Use: Bank I I 000 \ \ Hours of Operation: Mon. - Thurs. 9-5 SERIAL NUMBER: CA 3woassr 04� Friday 9_6 NRSP VERSION: 2.0 A00.52 \ ` Saturday 9-2 BULLETIN: 2017-3 \ Sunday Closed I (E)2J�x20' L Number of Projected Employees : 13 I E' EMEN NEW Number of Projected Users: To Be Determine ACIFIC BELL NEW - SEWER MONUMENT \ 2101 wm.a,slm.l —SIGN SEFZ,VICE ���Q \ sw zoao 2 — r__--_ -_-------------- ---- - -------, 5 J — Gensler T�lq c. 5106257413 \ SITE REQUIREMENTS TRELLIAGE r SCREEN PLANTING ® I \ so r1_11I1--'-�1 1 L k�k� kd kd 1 I 1 I EIN UNDERGROUND ELECTRICAL Bankof America of 08131/2017 WM H Homestead Road 02 10118117 WM AH T New ew Store RC LENGTH: 62.97' iiOAIE OEN6iR1:6980%TIO N CURVE 21020 Homestead Road RADIUS: 40W ZONING INFORMATION Cupertino, CA 95014 Proposed Use: Bank I I 000 \ \ Hours of Operation: Mon. - Thurs. 9-5 SERIAL NUMBER: CA 3woassr 04� Friday 9_6 NRSP VERSION: 2.0 A00.52 \ ` Saturday 9-2 BULLETIN: 2017-3 \ Sunday Closed I (E)2J�x20' L Number of Projected Employees : 13 I E' EMEN NEW Number of Projected Users: To Be Determine ACIFIC BELL NEW - SEWER MONUMENT \ 2101 wm.a,slm.l —SIGN SEFZ,VICE ���Q \ sw zoao 2 — r__--_ -_-------------- ---- - -------, 5 J — Gensler T�lq c. 5106257413 \ SITE REQUIREMENTS TRELLIAGE r SCREEN PLANTING ® I \ so r1_11I1--'-�1 1 L k�k� kd kd 1 I 1 I EIN UNDERGROUND ELECTRICAL IQ I„•, oamalaa�a Raacrlptlen evc, of 08131/2017 WM H PLANNING COMMENTS#1 02 10118117 WM AH PLANNING COMMENTS#2 SERVICETEUDATA NEW s. SERVICE ■IAJ '. Iso ansl9wmre Ieralaat HR VEST. IMEDIUM CFewle Nam• I r— [ 1 Lu PROPOS E9 O i a 02 TRASH LOADING A00.52 12 I I I L-- RFMnVF fFI FI Fr:TRIr.AI TRANCFl1RMFR 1-1 RAISED ACCESSIBLE PATH TO TRASH ENCLOSURE 0 TYP arsr a:ILY PROPOSED PARKING Q TIM; Appiicai�W� N6, lW 9 (4) N1 N6�zq�_--_ FROM CU(tB, TYP. (E) BUS STOP ` Fac hik: 5106257499 SETBACKS - Title 19: Front Setback: 22 FT (building height). HEIGHT: Height Limit = 30' at Stelling Gateway Area Proposed Height = 22' Proposed Number of Stories = One Story PAVING AREA 12,782 sf existing 15,730 sf proposed replacing all of the existing paving. 62%of site as paving LANDSCAPED AREA 203 sf corner landscaped area 641 sf parking lot landscaping 5,786 sf total 23% of lot area PARKING -title 19 19.124: Z Proposed Building Size: 4172 SO. FT. co Space/sq.ft.: 250 per SO. FTG. �( = 17 spaces reqd. 33 spaces provided (None are Compact Spaces) Z Bicycle spaces = 1 / 1250 sf bldg. C) 4 spaces reqd. at entrance Accessible parking spaces required = 2 0 Of which one is required to be a van accessible parking space Q per CBC 11B-208.3 Clean Air Vehicles per CAL Green 3 spaces required. One full -foliage tree for every 5 parking spaces = 7 trees 4% of site dedicated to bio swale surface as our new impermeable surface parking lot is> 10,000 sf LEGEND so (E) STORM DRAIN TO REMAIN (E) CITY UTILITY POLE TO REMAIN I NEW PARKING LOT LIGHT STANDARD LOCATIONS (E) PROPERTY LINE (E) CHAIN LINK FENCE (N) GAS METER LOCATION --------UNDERGROUND UTILITY SERVICES EXISTING SITE USES Existing Office Building 5265 V Existing Uses include: Chiropractors, Beauty Salon & Massage Therapist Existing Building Height 14,8' Existing one-story building R.O.W. REQUIREMENTS Dedication of 10'-0” Wide Right Of Way strip at each public way for City Sidewalk and planting strip. Applicant provides plat map, City will write the dedication. lo'-0"from face of existing street curb. 1 IQ I„•, oamalaa�a Raacrlptlen evc, of 08131/2017 WM H PLANNING COMMENTS#1 02 10118117 WM AH PLANNING COMMENTS#2 '. Iso ansl9wmre Ieralaat Bank of America -Homestead Road I pr•terypa Layout IMEDIUM CFewle Nam• Ioa:2502.002 �npuo• PROPOSED SITE PLAN f t1 0 2' 4' 8' 16' A OO.5O x•c xo,u �•� J HOMESTEAD ROAD F.A.R. CALCULATION 4172 SQ. FT. Net Lot Size: 24,163.01 SQ. FT. Bank ofAmerica ' ZONED: P(CG) Homestead Road APN: 326-07-020 New Store Parcel B Existing Lot Size: 25,422.15 SQ. FT. From (E) Survey 21020 Homestead Road (N) Street Easment: - 1,259.04 SQ. FT. (subtract) Net Lot Size: 24,163.01 SQ. FT. Cupertino, CA 95014 Building Size: 4172 SQ. FT. Net Lot Size: 24,163.01 SQ. FT. FAR: .17 Proposed Use: Bank SERIAL NUMBER: CA NRSP VERSION: 2.0 BULLETIN: 2017-3 2101Nchsla Str Swt� 2000 -d, CA 94612 Gensler Rlclph 510.6:5.7413 Facsimile: 510.625.7499 z m z 0 0 4 =.o Issue 6lszuv Ovscriplivn Lkeck 01 081312017 WM AH PLANNING COMMENTS #1 02 10111/17 WM AH PLANNING COMMENTS #2 IPrvlvc[Namv Bank o1 Amedca - Homestead Road IP'.­YPv YvMEOIUM ILPp Flle — 11-2502.002 lo:�capoo� SITE DIAGRAM FOR FAR CALCULATION 0 2' 4' 8' 16' A00.51 T.°r METAL ROOF STRUC1 CRETE APRON TRASH ENCLOSURE ROOF PLAN 10 COVERED TRASH ENCLOSURE PLAN 02 SCALE: 112"=1'-0" A prr O AL 0 X1-4 e.3.w".i- r )7.02 SPACED SIDING ALL 4 SI 1 PAINTED STEEL DOORS I ELEVATION TRASH ENCLOSURE 03 SCALE: 112"=1'-0" �v v t erlrs L� i a 1r+". I , SEAT WALL FACING MATERIAL GRADE PRECAST CONCRETE WALL EDGING WI SKATEBOARD DETERRENTS CONCRETE SEAT WALL AT STREET CORNER PRECAST LEDGESTONE WALL FACING: CORONADO PRO LEDGE OAKBROOK WALKWAY SEAT WALL nA SCALE: NONE DT_&W-()086 SCALE: 1112"=V -O" DT MW 0086 KEY NOTES BankofAmerica'®" Homestead Road New Store 21020 Homestead Road Cupertino, CA 95014 SERIAL NUMBER: CA NRSP VERSION: 2.0 BULLETIN: 2017-2 z1D1 wcncrm svcm Gensler Tlcphc 510.625.1113 Facsimile: 51-5.119a D.sc '— By cnca 1a01a 08131/2017 WM AH PLANNING COMMENTS 15e 11519naturo IP.J-N... Bank of America -Homestead Road IP1t.WP1 tar- Ic�E01UM D Fllc Namo 33.2502.002 (Dcunnb- SITE DETAILS Iscaia ASINDICATED A00.52 Nef. NorN k of America mestead Road w Store 0 Homestead Road rtino, CA 95014 9L NUMBER: CA ' VERSION: 2.0 ,ETIN: 2017-3 2101 IV Wt.,S— CA N612 nsler w h e: 510.6'3.7413 Farsimil.: 510.625.7499 o.f.ai:... o..moa.. By Ch - )l 08131/2017 WM AH PLANNING COMMENTS 91 )2 10/10117 WM AH PLANNING COMMENTS C2 menta • Homestead Road fANCE DIAGRAM �� i6' 32' X0.53 NORTH ELEVATION - HOMESTEAD ROAD SCALE: 3116" =1'-0" EE -01 Wt5 I tLtVA I IUN - 51Ut 2 SCALE: 3116" =1'-0" EE -01 SOUTH ELEVATION - REAR 4 SCALE: 3116" = V-13" EE -01 APPR9VAL Applicadon Number e� .. lila er EAST ELEVATION - N. STELLING ROAD 3 SCALE: 3116" = 1'-0" EE -03 NOT A PART OF THIS SUBMITTAL BUILDING SIGNAGE SHOWN FOR INFORMATION ONLY— BUILDING AND SITE SIGNAGE UNDER SEPARATE CITY APPROVALS. Bank of America �! Homestead Road New Store 21020 Homestead Road Cupertino, CA 95014 SERIAL NUMBER: CA NRSP VERSION: 2.0 BULLETIN: 2017-2 2101 W.bin S-1 Gensler 'TcicpA nc: IWAZ5.143 Facsimile: 510.625.7499 I zOzzcxpxan By 0- 01 Isa 06/31/2017 WM AH PLANNING COMMENTS I5, MSlgnatura Prc,eeJ Nama Bank of America- Homestead Road Pltetypp Layout MEDIUM ICAD FHa Name 33.2502.002 IDeu„ptloD EXTERIOR ELEVATIONS j—,. 3116'=1'-0' 00 P' A09.11 EXTERIOR FINISH SCEDULE STUCCO 1 PLASTER (BASED ON PAREX STUCCO) _ [BAC PRESCRIPTIVE] I -BASIS OF DESIGN- , - 9.1 IN87mNDRA•,SANORNSFINISH ST, 1NB2WARMSwWWDRNERNISH - ST. INJT•MOSS*.SMOONFUIISH ALUMINUM COMPOSITE METAL PANEL [BAC PRESCRIPTIVE] I"BASIS OFDESIGN- ESIGN- Ism.RED' WMMBTR Ism.— ACM,2 'RVW VMITE'o1MIJJRVW ACMJ NATCH STOREFRONP GLAZING [BAC PERFORMANCE] _ [L-1 1'HEATSTREIIGTHENEDCLFPAINS=TEDGIFLNo GL -2 VTWPEREDIASUTATEUGIABNG GW 10nsMPEREDMONOLRHICGIASS CL -J SE-TEMPEREDMONOLRHICGIASS ALUMINUM GLAZING FRAMES [BAC PRESCRIPTIVE] I "BASIS OF DESIGN" 21020 AG -1 CURTNNWALLSYSTEM ACh1.1 AF2 STOREFROMSYSTEM STUCCO ACCESSORIES (ALL PAINTED EXPT-3) Sal vnoEDLwxEL scPFED Saz xARRD•ncxAxxELscREEa SA,1 MODIFED CHANNELSCREED METAL COPING [BAC PERFORh1ANCE[ MGI PREFNISHEO METALOOPING CUSTOM COLORTOMATCH ST pp -3 EXTERIOR PAINT [BAC PRESCRIPTIVE]/ R.HCA0OFDES1I1E EYPT-1 INI85J COLOR:HC-102'CIARKSVILLEGRAY, MATCHES 5T3: AI05G - ENPT-2 [1,1185]COLOR:HCBD SLEEKER BEIG_,MATCHES ST3: WARM SAND ST -2 ST -1 E a INnlq COLOR:OASSIC NIONSTONEHOUSE, MATCHES ST-1:TUNDRA DPT -5P251 COLOR'k213150 PIGEON GRAN (BASED ON BENJAMIN MOORE) NORTH ELEVATION - HOMESTEAD ROAD SCALE: 3116" =1'-0" EE -01 Wt5 I tLtVA I IUN - 51Ut 2 SCALE: 3116" =1'-0" EE -01 SOUTH ELEVATION - REAR 4 SCALE: 3116" = V-13" EE -01 APPR9VAL Applicadon Number e� .. lila er EAST ELEVATION - N. STELLING ROAD 3 SCALE: 3116" = 1'-0" EE -03 NOT A PART OF THIS SUBMITTAL BUILDING SIGNAGE SHOWN FOR INFORMATION ONLY— BUILDING AND SITE SIGNAGE UNDER SEPARATE CITY APPROVALS. Bank of America �! Homestead Road New Store 21020 Homestead Road Cupertino, CA 95014 SERIAL NUMBER: CA NRSP VERSION: 2.0 BULLETIN: 2017-2 2101 W.bin S-1 Gensler 'TcicpA nc: IWAZ5.143 Facsimile: 510.625.7499 I zOzzcxpxan By 0- 01 Isa 06/31/2017 WM AH PLANNING COMMENTS I5, MSlgnatura Prc,eeJ Nama Bank of America- Homestead Road Pltetypp Layout MEDIUM ICAD FHa Name 33.2502.002 IDeu„ptloD EXTERIOR ELEVATIONS j—,. 3116'=1'-0' 00 P' A09.11 TRELLIAGE SCREEN PLANTING DRIVEWAY O In OFFICE a� Q SIDEWALK TRANSVERSE SECTION THRU HOMESTEAD ROAD A-A� SCALE: 118" =1'-0" DISH TRELLIAGE — SCREEN //�� PLANTING BREAK I � ELECT. NETWORK ROOM OFFICE I DRIVEWAY I UNDERGROUND ELECTRICAL TRANSFORMER INTERIOR (f ATM L44=11 I i ��. 24 HOUR VESTIBULE SIDEWALK - �I N.N. STEd LONGITUDINAL SECTION THRU N. STELLING ROAD B_BI SCALE: 118" = V -D" ankofAmerica ''!" Homestead Road New Store 21020 Homestead Road Cupertino, CA 95014 SERIAL NUMBER: CA NRSP VERSION: 2.0 BULLETIN: 2017-2 vol wcualR svcn Gensler Tdgh ne: 510.635.7413 F..imilc: 510.623.7499 IAism. om.alssu. o.scnPnon eycx.ca 01 08/312017 WM AH PLANNING COMMENTS ISe ISlgnamm IPr.l.etxam. Bank of A-6. - Homestead Road IP1—yp. Layo.t IMEDIUM AO FII. Nam. 33.2582.802 lo.acncu.. BUILDING SECTIONS 1-1. 118'=1'4' 0 2' 4' 8' 16' A09.15 Application Numbe, TRELLIAGE SCREEN PLANTING DRIVEWAY O In OFFICE a� Q SIDEWALK TRANSVERSE SECTION THRU HOMESTEAD ROAD A-A� SCALE: 118" =1'-0" DISH TRELLIAGE — SCREEN //�� PLANTING BREAK I � ELECT. NETWORK ROOM OFFICE I DRIVEWAY I UNDERGROUND ELECTRICAL TRANSFORMER INTERIOR (f ATM L44=11 I i ��. 24 HOUR VESTIBULE SIDEWALK - �I N.N. STEd LONGITUDINAL SECTION THRU N. STELLING ROAD B_BI SCALE: 118" = V -D" ankofAmerica ''!" Homestead Road New Store 21020 Homestead Road Cupertino, CA 95014 SERIAL NUMBER: CA NRSP VERSION: 2.0 BULLETIN: 2017-2 vol wcualR svcn Gensler Tdgh ne: 510.635.7413 F..imilc: 510.623.7499 IAism. om.alssu. o.scnPnon eycx.ca 01 08/312017 WM AH PLANNING COMMENTS ISe ISlgnamm IPr.l.etxam. Bank of A-6. - Homestead Road IP1—yp. Layo.t IMEDIUM AO FII. Nam. 33.2582.802 lo.acncu.. BUILDING SECTIONS 1-1. 118'=1'4' 0 2' 4' 8' 16' A09.15 .'Autumn Blaze' Tine IG Olde O maturity A., '.o Fast graCtOrsle f Davy soils or soggy ground nage s0ales) la tree, briniad red foliage In too Zelkova wnubta'Gme Vase' re -. yi PLANT LEGEND Perennial fl R/tlmme) SYMBOL I QTY. SIZE BOTANICAL NAME COMMONNAME SPACING/NOTES TREES l - Maderete crater 9 R' Tole.ld of Davy calls, drougOt, DM / •� T7 5 24 Acer rubmm'Auwmn Blain' Rod MaPle - T2 2 24 Zak ova wmrlaW'Gm,a Vaso' S,Eleaf Zelkova Tree Gratesh Sidocalk Area T3 9 24 Lag"Ine"WTuscarora' Crape MyN. - SHRUBS 34 l( �+! •T Y SOsOy Beal, In Summer, Fall fonage color ( Evergreen SOub w r " �Y` tae S7 14 5 OsmaatCu DleropDrius Vadegate Holly Leaf Osm.mQ. Spaced 048'... max, S2 12 5 Loropetalum cdnsa, 13,rgundy COn.se Fring.R.Oer - S3 17 5 Nndins domestics'G,Ystmam' Heaveny Bamboo Spaced 036'o.c. max. S4 18 5 Cistus Gybrid. Wale Rocksce S5 8 5 Cowulaucium und-hure'Purple Pddo' GWaIdWn Wax FI,Cer S6 11 1 Coleorues pukDlW'Sunaet Gold 8ratOof Heaven - GRASSES I PERENNIALS I ROUNDCOVER/VINES G7 35 1 Rosmarinus oRclrafn'Pmanawm' Rosemary Spaced 0470.1. max. G2 160 1 MuOenbergis litd0simeri'Autumn GI,O' MaOy Grew TrlargWarspaced036'o.c.max. G3 11 5 PD.W.'Mwri Maiden' N.0 Zwb dI Flax G4 65 1 Catoneaster dammed'Lo❑last B -lb. yC.Waaster Spaced 48' ..c. max. G5 14 1 Coreopsis v,ricilWW'Mwnbeom' Tor dIwfTIckwed Spaced 024 o. o. max. G6 1 38 1 1 1 TuibegOa violacoa Soci ty Gadk Spaced 24'o.c. max. G7 72 1 Cytostome eolllstegiomas Vi.I tTmmpet Vm. - .'Autumn Blaze' Tine IG Olde O maturity A., '.o Fast graCtOrsle f Davy soils or soggy ground nage s0ales) la tree, briniad red foliage In too E, s A!� Zelkova wnubta'Gme Vase' re -. yi smWearZe#rwa Perennial fl R/tlmme) Deddu... T.e 78'tlg000ke0 maturity SG DBD/ 30'W 40 Gide 0 maturity `} Fk MadI Outer _ Moderate groGlOmle l - Maderete crater 9 R' Tole.ld of Davy calls, drougOt, DM / •� Not.pWWdtob..grit rdysuswptibla '� 5: a,.;;(�rP Y to pest hfoamtlons ord'soaw. "y ""'W'oomla Tusprora' Craps Myrtle ClYtestores callaleg oldos D ckluwsT.e • k L 20' [[go/ 16 Olde 0 maturity yr Maderelo Qatar Evegroen V no Silo to moda.w gro010mte Strong groCng vine but easily kept in cOcck Tolerantof DatOTusc win` D/brid selected +' i �M for Curdinew 0 resistance to mildeD 34 l( �+! •T Y SOsOy Beal, In Summer, Fall fonage color E, s A!� OsmantM. Cuta.pWI.s Vanog.W.' re -. yi Hogy Leer Osmangws Perennial fl R/tlmme) Evergreen Scrub 78'tlg000ke0 maturity B a maturity- ^-. 3 5' (Wik..pnmg,O.OarngO.Il f.r. Minimal Is Moderate Qatar tall Oldg.) Very WugoL Long-lived plant¢an survive Maderete crater OBOonly xcasianal Oster Variegated leaf color Ilgaens aMdy areas ikY 1f 1� - LWapeWlum c❑ne 1BugundY Chinese Fdnga Flower '� 5: a,.;;(�rP Y BARK MULCH. - "y Evergreen SQub 4' Olde max.0 maturity (lalms ClYtestores callaleg oldos pinnni!Wng a 0 scouringOen) • k L Regular Oster Bronze -purple foliageyear mundU calla Evegroen V no pink filso— In Spring, Intermittently for rest Strong groCng vine but easily kept in cOcck of too year +' i �M Handnodomesdca'GuYdream' 34 l( �+! •T Y Heevan/yBemboo ( Evergreen SOub w r " �Y` tae 3-1/2 tlg0/7-1rz' oke ❑ mawnry w Minimal W Moderate Cater d�� Sma00ate fbow, In Spring, milted foliage(red. yelloD green)year round Easy cere, extremey Wugo CIO. Lybddw WMfe Raekrose Evergreen Soul 4 Og D/ B Olde max. C maturity (lousily smaller, around 3 OgO by VOW.) Minimal Outer Carefree scrub blemM to droug0, Dat, poor will, Gird Wore %Care O/yegaO centers In Spring, Summer COun. aucwm..ms um'Psvplo Pride' GerabYarW Flower Evergreen SOub B ago/ G Oldo O maturity (can ba kept W 4'Culg❑OW gular pruning) Moderate Cater Blooms In late Winter IOougOSpring, covered In rosy pink W purple flo0ars Calomama puEDIW'Sunsst Gold' BreafhorHeaven Evergreen Scrub T clgot raid. 0 maturity Moderete Cater YelbOgold folaga year mundQirry pink floOem In Spring 0 Summer Rosman momclnalis'Prost.tum' Rosemary (Groundoover) Evergreen Scrub 7 Ggo/ 4 W B spread 0 maturity Minimal to Moderate Gator Very touga Curdy groundcovar Uga blue floCom horn lata Winter tonugO Spring Mu❑enbergle IitdDim.ri'Auwmn GloO' Muh/y Grass Perennial Grass 4 OgO/ 4 Olde (stalks may re -Oto 5) Minimal Oster Amber colored Blow ,Wiles In Autumn Selected for on-site drainage soots areas (oan M. in out areas despite minimal DaterreDlr.ment) PDrtnium'Mead Maiden' Na.Zea/erd Flax Long4iwd Perennial 4 C190/ 5 ❑ de 0 maturity Minimal to Moderate Cater 2. Olde strap ,0cpcd leaves in varying sold., of -for. cOetly bronzy red, cream 0 pink O/olive loaf etlgos Very Wug00 tolerant of poor caMYions Caton.aster dommed'loOfast Bealway0ohovessis, (Groundwve,) Evergreen Snub 1' Ogal laosp.ad 0 maturity Minimal aster Estmaslawytoug4 Drdygreandoo—O IivevmWyofCoton...ler Tiny ODO BoOersin Spr ngOed b.mW. in lata Fall TulbagOa vi,Iw,a NNNG TREES WILL NOT BE BALVA GED &YTO POD"RILLTHA00"R'INC0MPA nBLEu society Gadro LOCATION DUE TO PROPOSED SITE GRADING 0 NEW ORAINAG E FACILITIES. READERS ATTENTION Perennial fl R/tlmme) ISREFERRED TO THE ARBORIST REPORT (PREPARED BY0IKE MINNICK, ISA CERTIFIED ARBORIST VM -11830A), ACCOMPANYING THIS SUBMITTAL FOR ADDITIONAL INFORMATION ABOUT EXISTING 78'tlg000ke0 maturity TREE SPECIES ON SITE. EXISTING SOILS SHALL BE AMENDED PRIOR TO PLANTING PER RECOMMENDATIONS FROM SOIL Minimal Is Moderate Qatar NUTRITION REPORT. SOIL SAMPLES FROM PLANTER AREAS TO BE SUBMITTED TO A SOILS IAB Very WugoL Long-lived plant¢an survive FOR NUTRITIONAL ANALYSIS AND RECOMMENDATIONS. OBOonly xcasianal Oster ALL NEW LANDSCAPED AREAS TO BE TOP -DRESSED WITH A 3' LAYER OF RECYCLED BARK Pala lavender floor, MULCH. NO PLASTIC SHEETING OR IMPERMEABLE SURFACING SHALL BE ALLOWED BENEATH yearround,..A.st In Spring and Summer. BARK MULCH. - NEW LANDSCAPE PLANING WILL BE IRRIGATED USING NETAFIM TECHUNE (DRIPUNE) ON AN AUTOMATICALLY OPERATED IRRIGATION SYSTEM NEW TREES WILL BE IRRIGATED USING LOW ClYtestores callaleg oldos FLOW BUBBLERS SET IN VERTICAL PERFORATED TUBES TO ENCOURAGE DEEPER ROOT GROWTH. Violet r—pet v . NEW IRRIGATION SYSTEM WILL INCORPORATE AN AUTOMATIC IRRIGATION CONTROLLER WITH Evegroen V no WEATHER -SENSING CAPABILITY FOR OPTIMAL WATER SAVINGS. Strong groCng vine but easily kept in cOcck ALL PLANT MATERIAL SELECTED FOR THIS SITE IS COMPATIBLE WITH NORMAL CLIMATIC oitoccossionalpmnng. Runners can g,Q CONDITIONS FOR SANTA CLARA COUNTY. NONE OF THE SELECTED PLANS ARE REPORTEDTO 19'n a g.0ing sween BE UNSUALLY SUSCEPTIBLE TO PEST INFESTATION. VIRUSES OR DISEASE Regular nater PLANT MATERIAL SELECTED FOR THIS PRO ECT GENERALLY HAVE A LOW TO MODERATE WATER USERATE. NO LAWN TURF OR HIGH-WATER USAGE PLANTS ARE PROPOSED FOR THIS SITE. Violet and OOW flo0.m In Spdrg. 01, @Sig 8aiurs BankofAmerica''� Homestead Road New Store 21020 Homestead Road Cupertino, CA 95014 SERIAL NUMBER: CA NRSP VERSION: 2.0 BULLETIN: 2017-2 2101 Webster Street Suite 2000 ns Oakland, CA 94612 GeTelehom, 111.121.1411 nsler Facsimile 510.625.7499 Landscape Architccrae: Pavement Engineering inc. You ran side on our mputalion b, :: WS SSpraamnroU a,S H 81OW.spo, CA BNOIAalS B8S)Bf-TT65 PaRm.. E.13—rWQinc. Atm: Ofwdun Edholm, Probst Nlca.ae 30L0 Cpres, Ori¢, Suite 3 P.Wl—CA 91954 T. 707.769.5330 F.msB: Mcosh... poOsncntenoncerinOcom lards., A.M-1: Mike Wesdm Liceme:CAO" EGP.10010010 ' Issue Dara a Issue Descdprion By Check Ot 5120/17 MPW MPW Pre -Planning Submittal ' 02 10/11117 MPW MPW Planning Submittal #2 )e Nanta i—�— �� I I(Ame�a• on si kJAad Road Cas,. I SHEET L.01 €__ "CITVSTONECOMBWBYPAVESTONE. Available ina wri.ry offinishes, this paver combo brings style and dimension to architectural servings. City St.n —ba used W, -n binalion modules of symmetrical squares and rectangular shapes to create extraordinary pattoms and mbas dosigns. This paving p,U,,n combines M, 6x12" City Ston. Rectangl., [ho 12',12" CityStone Square, and the 6x9- City Stan, R.ctangl.. US FOUNDRY -ADA COMPUANT TREE GRATE(MODEL9501). Cast iron tree grata. 48'sOraro, ADA oampliant to, ..[king sudaces. 3x3 (TYP ) ;I I I I I ECO-MESHDScre,ns or, mad. with a heavy 0.12wovoniremost, screenvnth,aniquo bridge win, far st.biliarrii—This gaagois2-1/2limesstrangerthan.080wire found in t' /L � � -7—gq c.mp.bngpraductsOurspaculint.rcdmp.eaveprovdest@fl,xblitYpt.nl Screemre0ire.ndelmmalesbmkon Ueldst®twnoccurinotl rbrand, qqq ^/� && �ll+++��� ECO-MESHDscmonsar.(mm.donfoursdesbydur.blel6gaugom.txleh,n,,lwhrchls25%ho.viarthanl8gaugofmm.eommonlyfo,,d noth,rproducls. 9�C i g a� d� mate sx+rara�F„""] 9 dr.•! L�yg W.a _ .. DAVIS Concrete .1., #375, SO Tan _ - :r >< Ws::zse d�cil�' E' STEEL POST 0 4'-S' O.C. STEEL MESH PANEL ECO -MESH BY McNICHOLS CORPC4' WIDE, 6 TALL, DARK GREEN mum BankofAmerica''� Homestead Road New Store 21020 Homestead Road Cupertino, CA 95014 SERIAL NUMBER: CA NRSP VERSION: 2.0 BULLETIN: 2017-2 2101 Webster Sheet Suite 2000 Oakland, CA 94612 Gensler Telephone 510.625.7400 Focsimile 510.625.7499 L.orl cape Amhi­b.e: Pavement Engineering Inc. You can ride on our reputation oryaca COr rd BQBS Sammenr. arNe. BulreA m- -1., CA ssial— B"7813Z65 Amr 3o [hao Ed dn.l... Ann: ED.s rata, Slit. plana@r Pno I -lapse N95 Sui1c3 Pccaluma, CA ?1951 T: ]07-]69-5330 E- its mnananc. w@m.mm0nccdo.com latak. c A.Itilcn: Nlike Ward- Uccmc:CA01569 G[p. 1001001❑ Iss.a Oat.dlss.. DescdOnon By oh.ck 01 5126117 MPW MPW Pre -Planning Submittal 02 10111117 MPW MPW Pianning Submittal.2 s.allelgnatun Pml.n Hama Bank afAmnsa-Homestead Road 1—a—u-1 IP1.rotype LaY.m D-0pro- DECORATIVESURFACE TREAMENTS 'a ASSHOWN SHEET L.02 %H.m,. K.w." wi:wc u..o w'tli'wco'�d&.Cw:u`d°vYo`dcoAiin {sae 21 � � 1/e e23 1 /J 481/8 24 �i 1/2 ae �1/a US FOUNDRY _ /2 �Y3� I� ( SiiP USF 9501 TREE GRATE^ ADA Com taint 32 at, 2 03-05-11 ULS acv: 0 0, mo¢. US FOUNDRY -ADA COMPUANT TREE GRATE(MODEL9501). Cast iron tree grata. 48'sOraro, ADA oampliant to, ..[king sudaces. 3x3 (TYP ) ;I I I I I ECO-MESHDScre,ns or, mad. with a heavy 0.12wovoniremost, screenvnth,aniquo bridge win, far st.biliarrii—This gaagois2-1/2limesstrangerthan.080wire found in t' /L � � -7—gq c.mp.bngpraductsOurspaculint.rcdmp.eaveprovdest@fl,xblitYpt.nl Screemre0ire.ndelmmalesbmkon Ueldst®twnoccurinotl rbrand, qqq ^/� && �ll+++��� ECO-MESHDscmonsar.(mm.donfoursdesbydur.blel6gaugom.txleh,n,,lwhrchls25%ho.viarthanl8gaugofmm.eommonlyfo,,d noth,rproducls. 9�C i g a� d� mate sx+rara�F„""] 9 dr.•! L�yg W.a _ .. DAVIS Concrete .1., #375, SO Tan _ - :r >< Ws::zse d�cil�' E' STEEL POST 0 4'-S' O.C. STEEL MESH PANEL ECO -MESH BY McNICHOLS CORPC4' WIDE, 6 TALL, DARK GREEN mum BankofAmerica''� Homestead Road New Store 21020 Homestead Road Cupertino, CA 95014 SERIAL NUMBER: CA NRSP VERSION: 2.0 BULLETIN: 2017-2 2101 Webster Sheet Suite 2000 Oakland, CA 94612 Gensler Telephone 510.625.7400 Focsimile 510.625.7499 L.orl cape Amhi­b.e: Pavement Engineering Inc. You can ride on our reputation oryaca COr rd BQBS Sammenr. arNe. BulreA m- -1., CA ssial— B"7813Z65 Amr 3o [hao Ed dn.l... Ann: ED.s rata, Slit. plana@r Pno I -lapse N95 Sui1c3 Pccaluma, CA ?1951 T: ]07-]69-5330 E- its mnananc. w@m.mm0nccdo.com latak. c A.Itilcn: Nlike Ward- Uccmc:CA01569 G[p. 1001001❑ Iss.a Oat.dlss.. DescdOnon By oh.ck 01 5126117 MPW MPW Pre -Planning Submittal 02 10111117 MPW MPW Pianning Submittal.2 s.allelgnatun Pml.n Hama Bank afAmnsa-Homestead Road 1—a—u-1 IP1.rotype LaY.m D-0pro- DECORATIVESURFACE TREAMENTS 'a ASSHOWN SHEET L.02 :E SEE PG&E DR11f M, FOR CONTMAOGNI 1 1 1 I i - curt F1�B L 1 I I I 1 PROIARY FEEDERS I i 1 1 I ' I i -- I I 1 PGK CLEARANCE AROUND—'� UM VWLT -_. _.... S' CONDUIT—'t SECONDARY FEEDERS I NEW 400/A f L - lPH, 4WW SERVICE SERVILE •• III S#l'Sri�JY ie9.:.1� i \ UCR4 :JCR,} UCR2 I I 1 UCF.6 ACRS 588 IIp�Ht. FSF ACR'. � V 1�' FICLF N \ DREAM. RM. WAITING ENE] AM 0 3 N FF@ FINI i I I , PROPOSED PARKING ` M 1 aFI03 I i 3W I S' P TVAL DRC/A14 Signature ApplieaEioo Number /b,e'4 —/� Case I'+ VIEIgc�1: ELECTRICAL SITE PLAN SHEET KEYED NOTES BUILDING COMMISSIONING ARC ,62.7' 7',Q4.3 SaN tf�P; h ' cll2 . r L EIN. -:71 'A'37- OF THE WORK AND FULLY INFORM THEMSELVES OF ALL CONDITIONS THAT EFFECT THE WORK ANCOST THEREOF, AND EXAMINE THE DRAWINGS AND SPECIFICATIONS AS RELATED TO THE r.:in2' BE:N?2.+t•'. vT> D'ILv = O (E) UiLTY 7RANSIMIER TO BE REMOVED. SITE CONOITIONS. CD1 DNATE TEMOVAL " PC. PERFORMING THESE SERVICES ONEWUm VAULT FOR UNDERGROUND URUTY IRARSFDKTR It, TRAFRC—RATED COVER AND ASSEMBLY. VERIFY WIN PG&E ORAWNGS 3W I S' P TVAL DRC/A14 Signature ApplieaEioo Number /b,e'4 —/� Case I'+ VIEIgc�1: ELECTRICAL SITE PLAN SHEET KEYED NOTES BUILDING COMMISSIONING 1. CONTRACTOR PROPOSING TO UNDERTAKE WORK UNDER THIS DIVISION SHALL VISIT THE SITE 7',Q4.3 SaN tf�P; h ' A. TESTING AND ADJUSTING - TESTING AND ADJUSTING OF SYSTEMS SHALL BE PERFORMED IN ACCORDANCE OF THE WORK AND FULLY INFORM THEMSELVES OF ALL CONDITIONS THAT EFFECT THE WORK ANCOST THEREOF, AND EXAMINE THE DRAWINGS AND SPECIFICATIONS AS RELATED TO THE Pt-5m WITH INDUSTRY BEST PRACTICES AND APPLICABLE STANDARDS OF EACH SYSTEM AS DETERMINED BY THE BUILDING OFFICIAL PROVIDE A FINAL REPORT OF TESTING SIGNED BY THE INDIVIDUAL RESPONSIBLE FOR SITE CONOITIONS. c QAYFCTRHGI'pT PERFORMING THESE SERVICES 2. CONSIDERATION WILL NOT BE GRANTED FOR ANY ALLEGED MISUNDERSTANDINGS OF THE Bank of America -Homestead Road B. OPERATION AND MAINTENANCE (O&M) MANUAL - PROVIDE THE BUILDING OWNER OR REPRESENTATIVE WITH AMOUNT OF WORK TO BE PERFORMED. TENDER OF PROPOSAL SHAD. CONVEY FULL AGREEMENT TO THE ITEMS AND CONOITKM INDICATED ON THE DRAWINGS. SHOULD THE IMEDIUM DETAILED OPERATING AND MAINTENANCE INSTRUCTIONS AND COPIES OF GUARANTIES/WARRANTIES FOR EACH CONTRACTOR FIND DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS OR BE IN SYSTEM. O&M INSTRUCTIONS SHALL BE CONSISTENT WITH OSHA REQUIREMENTS IN CCR, TITLE B, SECTION DOUBT AS TO THE INTENT THEREOF, HE SHALL IMMEDIATELY 013TAIN CLARIFICATION FROM THE 16' 5142. AND OTHER RELATED REGULATIONS ENGINEER AND/OR OWNER'S REPRESENTATIVE PRIOR TO SUBMITTING NS PROPOSAL FOR WORK C. INSPECTIONS AND REPORTS - INCLUDE A COPY OF ALL INSPECTIGNS, VERIFICATIONS AND REPORTS, REQUIRED A FIELD VERIFY EXACT NAMEPLATE DATA ON ALL EQUIPMENT FMRNSHED UNDER OTHER BY THE ENFORCING AGENCY. DIVISIONS AND/OR BY THE TENANT O.E. HVAC EOUHPIAENT, KITCHEN EOUIPMENT, COMPUTER EOUIPMENT. ETC...) PRIOR TO THE INSTALLATION OF ELECTRICAL WORK AND MAKE ANY AWLM MENTS TO OUTLETS. CONDUTTS. WIRE AND/OR CIRCUIT BREAKER AS REQUESTED TO MATCH EOUIPMEM ACTUALLY FURNISHED. 4. REFER TO SPECIFICAPO S SECTION 16110 FOR UNDERGROUND CONDUIT REQUIREMENT. i ALL CONDUCTORS SHALL BE COPPER CONDUCTORS FOR ABOVE GROUND SUMCE SALL BE THM - THWN. CONDUCTORS FOR BELOW GRADE SERVICE SHALL BE THIN OR XHHW. CONDUCTOR III) AND SMAI.ER SOUL BE SOLID. CONDUCTORS /B AND LARGER SHALL BE STANOEDk, E PI E-0.0 SIEE73 SITE .W EP-1.SITE PHOTO METRIC IF-ty PHOTONETRNG GUTSIEEIS CALGREEN BUILDING CODE REQUIREMENTS SHEET GENERAL NOTES SHEET INDEX Bank of America -;Qp- Homestead Road New Store 21020 Homestead Road Cupertino, CA 95014 SERIAL NUMBER: CA NRSP VERSION: 2.0 BULLETIN: 2017-2 21011W.115OM Gensler Tl ph.. 510.6x3.7413 Fud,nile: 510.625.7499 11L ssuD Date 6lssuc Oescnpl on By CI0012412017 PLANNING COMMENTS I=� AGES✓RR0FFS6q ENGINEERING 7',Q4.3 SaN tf�P; h ' 1711 acdl StreN sDOta4.)5 N0.E015418 Pt-5m MLMLM (401) 522Z- IDTDl ledec.001 c QAYFCTRHGI'pT COPAi9�IQ20D _ OF CALIE a Bank of America -Homestead Road IPmtoHDO LDYDuI IMEDIUM IDesctlptlOn SHEET INDEX & SITE PLAN IIssc 1 r.L,�® I f1 0 2' IC IT 16' E -U.0 Ref. NOrlh DATE OF FIELD SURVEY APRIL 15, 2017 SURVEYOR'S STATEMENT THIS MAP WAS PREPARED BY ME, OR UNDER MY DIRECTION, IN CONFORMANCE WITH THE PROFESSIONAL LAND SURVEYORS' ACT. J. MAY, PLS 8570 03/31/2019 DETECTOR -- - - - - - - FL 225.42' - TC E 22589' Bw E 225.95 Tc S DATUM STATEMENT COORDINATES SHOWN ARE BASED ON CALIFORNIA STATE PLANE NORTH AMERICAN DATUM (NAD83) ZONE III, (EPOCH 2011.00). ALL MEASURED DISTANCES SHOWN ARE US SURVEY FOOT GRID DISTANCES, UNLESS OTHERWISE NOTED. TO OBTAIN GROUND DISTANCES DIMDE GRID DISTANCES BY A COMBINATION FACTOR OF 1.000067014 20' 10' 0' 20' 40' GRAPHIC SCALE: 1 INCH = 20 FT BASIS OF BEARINGS THE BASIS OF BEARINGS FOR THIS MAP IS THE MONUMENT LINE OF CHERRY STREET, AND TAKEN AS NORTH 89'08'14' WEST, FROM FOUND MONUMENT POINT 106. REFRENCE 11) 167 ROS 23 BOOK 167 MAP 23 HOMESTEAD ROAD (90' WIDE) �[� 106 -�- - - - - - - _ - - - -�ST BM I -ELECTRIC CABINET _ TC E .99' v BW S224 .. .. N �4�. 22 N225.4` 225.51' ,.+ N8 m 100 +225.225.1 223.45 PACBELL EASE 1^� 101 DOC NO. 13769176 220.25 AT&T UNDERGROUND 102 CABLE BOX W/CONC. 224.10 PLATFORM 103 24' PAW 224.82 p. 5 104 TC 224.57 225.27 24' PAW - d 5 225.21 8' CHAINUNK FENCE -- DI 275" GRATE EL =223.49 - INV. EL =220.89 225'15 INV. 6' RCP OUT (E) = 221.64 TC 225.12' - TC _ 225.17 1C 225.29' 24' PAW - DL 5' DUMPSTER ARE 2L ! MMXIOU2S� ELECTRIC CABIN. VICINITY MAP « 223.8• 35' DL TD Bw S Tc OB 224.SC Tc 224.47 22el 223.50' Tc 224.26' Tc 57 224.26' 224.13' T�BB, DETECTOR DRIVE Bw • E TC GB +..67, �,) 2u47 CROSS WALK BUTTON 25 s TC 129.17 p' 224.87 NM 224.7' + i 22 73 7 . t LAWN + 224.D' ■ 7C \j + 225.5' 11224.92' 25 '^/ DL 15' ? + 8114 +224.2• 22292' J If DEMUOItr''24' DEcmuous m 22155' 224.7 1 0B _.... DL 1:f / LEGEND .� 4 p e ny f DL 15 lg.90el0 221.2,' i r 725,42' 7C '2 m-?�o°P• 225,E 2z 75 1 ,/! %, f! f /" / 'i ' / `�•Oo, lour x azx21' ELECTROIJER WITH ARM Bw is DI 122 _4,• X22_121 GRATE EL 223.22 d" WATER METER / / 22139' 22M 122 INV. EL = 219.42 Sx -- / BUILDING OVERHAN BW INV. RCP IN219.62 TREE 24 ! 43. I INV. 24' RCP OUT (N (NE) 216.92 BUILDING TC ssD FF=225.69223.27 ® FIRE DEPARTMENT CONNECTION + I+224.27 / 2 4."3 ` / 1 I .1 POST INDICATOR VALVE m 2' PARCEL B / LAWN 'B 167 ROS 23 2: ELECTRDUER 22169' / GAS SERVICE Bw,Q2s` �' CATCH BASIN +=in.3.:• BUILDING OVERRAN tea. o' - S Z / TC E 22150' AC PAVEMENT / . E51 ' - mss.. o c 24 DEC�UOUS I , (./) d" GAS METER 22& -DL 10' 9 22,.E to I l O SANITARY SEWER CLEANOUT DOORCONC. WALKWAY 22143' TC ESC 0 725�- ".�•• • _BW E 22 iV �•'�' n. - 1C T� �''� I z TRAFFIC SIGNAL LIGHT 2.S.C7' 22y,�. 1C B WALK 28. 27517 ?254 1044ry 225.49' 1C s o "' PARKNG LOT 214- TC �- TC 52211 7 mc ; ' 224.92' \b 224.67' +2"<4.5.f' ?2355' /+22 U" 3 221W Q D WATER VALVE .13' ' 224.17' 4 224.23' AC_ A ENT �-' I 1 224.51' b O UNKNOWN VAULT M ESC is 225.15E + 224.39` +224.8£ +224.73' + 22.4.33• 4.tB 7f 102 CINDER BRI K W__- 22168' FL s X ON cuBB SIGN z4.ia' TC +22, ' �f TC 5273.68' I -(� 215. 11 17Bn 22178' TC E C• 224. T� TC E - 225.01'225-41 O TOWILL CONTROL 22{.95 TC 275 224.59• TC p-1' 224.13 4.B7 224 35' 7C FL E N 89'47'0 ' E f5Y 15' 224.4 22168' +o+ FIRE HYDRANT 1' TC E 'IV41' 134.1 Z 215.05' 8' TREE '' 21155' 22513' d. 1' DL t' ?6 , . � 41 R 5m9 I TRAFFIC SIGNAL rvicus +"s.2• ELECTROLIER :,. 22e.rs 93 fu.Im Y B' CHAINUNK FENCE ON 24' CONC. BASE TELEPHONE VAULT ,. +..� TC s 11151 I cr GAS METER DI 1058 PARCEL A GRATE = 223.71 = INV. EL = 22D.71 , � I � GAS VALVE INV. 6' RCP IN (W) = 220.74 167 ROS 23 INV. RCP OUT (N) - 220.64 CURB RAMP � I I ( y1•'i]�7 W/PM UNDERGROUND WATER PAINT MARK ,7.- G/PM UNDERGROUND GAS PAINT MARK. O O O FENCE D' ` UNDERGROUND STORM DRAIN PAINT MARK 1 I L_ ABBREVIATION AC ASPHALT TC TOP OF CURB FL FLOW UNE GS GRADE BREAK CONC. CONCRETE SSC START SMOOTH CURVE ESC END SMOOTH CURVE S START E END o am0 O moC, U �9 un V)w�N � 6 f6 -200 T U o 1fl 0) O U j Z pN c\I n w O N m W ISA Z � n N O 90 O SHEET [ OF 1 SURVEY CONTROL POINT# DESCRIPTION ELEVATION NORTHING EASTING 100 CUT X 223.45 1949002.90 6113486.60 101 CUT X 220.25 1948631.90 6113585.18 102 X ON CURB 224.10 1948877.97 6113499.61 103 N/S 224.82 1948905.68 6113388.97 104 N&S 224.57 1949017.31 6113392.50 105 CITY BM 16 1 223.26 1948987.20 16113502.82 106 ST BM 222.53 1949062.34 6113548.77 1002 END ST MON 227.1D 1949069.73 6113057.90 1003 FND S7 MON 228.15 1949074.31 6112727.08 5019 ED RCE 10007 223.14 1948848.34 6113499.53 22 73 7 . t LAWN + 224.D' ■ 7C \j + 225.5' 11224.92' 25 '^/ DL 15' ? + 8114 +224.2• 22292' J If DEMUOItr''24' DEcmuous m 22155' 224.7 1 0B _.... DL 1:f / LEGEND .� 4 p e ny f DL 15 lg.90el0 221.2,' i r 725,42' 7C '2 m-?�o°P• 225,E 2z 75 1 ,/! %, f! f /" / 'i ' / `�•Oo, lour x azx21' ELECTROIJER WITH ARM Bw is DI 122 _4,• X22_121 GRATE EL 223.22 d" WATER METER / / 22139' 22M 122 INV. EL = 219.42 Sx -- / BUILDING OVERHAN BW INV. RCP IN219.62 TREE 24 ! 43. I INV. 24' RCP OUT (N (NE) 216.92 BUILDING TC ssD FF=225.69223.27 ® FIRE DEPARTMENT CONNECTION + I+224.27 / 2 4."3 ` / 1 I .1 POST INDICATOR VALVE m 2' PARCEL B / LAWN 'B 167 ROS 23 2: ELECTRDUER 22169' / GAS SERVICE Bw,Q2s` �' CATCH BASIN +=in.3.:• BUILDING OVERRAN tea. o' - S Z / TC E 22150' AC PAVEMENT / . E51 ' - mss.. o c 24 DEC�UOUS I , (./) d" GAS METER 22& -DL 10' 9 22,.E to I l O SANITARY SEWER CLEANOUT DOORCONC. WALKWAY 22143' TC ESC 0 725�- ".�•• • _BW E 22 iV �•'�' n. - 1C T� �''� I z TRAFFIC SIGNAL LIGHT 2.S.C7' 22y,�. 1C B WALK 28. 27517 ?254 1044ry 225.49' 1C s o "' PARKNG LOT 214- TC �- TC 52211 7 mc ; ' 224.92' \b 224.67' +2"<4.5.f' ?2355' /+22 U" 3 221W Q D WATER VALVE .13' ' 224.17' 4 224.23' AC_ A ENT �-' I 1 224.51' b O UNKNOWN VAULT M ESC is 225.15E + 224.39` +224.8£ +224.73' + 22.4.33• 4.tB 7f 102 CINDER BRI K W__- 22168' FL s X ON cuBB SIGN z4.ia' TC +22, ' �f TC 5273.68' I -(� 215. 11 17Bn 22178' TC E C• 224. T� TC E - 225.01'225-41 O TOWILL CONTROL 22{.95 TC 275 224.59• TC p-1' 224.13 4.B7 224 35' 7C FL E N 89'47'0 ' E f5Y 15' 224.4 22168' +o+ FIRE HYDRANT 1' TC E 'IV41' 134.1 Z 215.05' 8' TREE '' 21155' 22513' d. 1' DL t' ?6 , . � 41 R 5m9 I TRAFFIC SIGNAL rvicus +"s.2• ELECTROLIER :,. 22e.rs 93 fu.Im Y B' CHAINUNK FENCE ON 24' CONC. BASE TELEPHONE VAULT ,. +..� TC s 11151 I cr GAS METER DI 1058 PARCEL A GRATE = 223.71 = INV. EL = 22D.71 , � I � GAS VALVE INV. 6' RCP IN (W) = 220.74 167 ROS 23 INV. RCP OUT (N) - 220.64 CURB RAMP � I I ( y1•'i]�7 W/PM UNDERGROUND WATER PAINT MARK ,7.- G/PM UNDERGROUND GAS PAINT MARK. O O O FENCE D' ` UNDERGROUND STORM DRAIN PAINT MARK 1 I L_ ABBREVIATION AC ASPHALT TC TOP OF CURB FL FLOW UNE GS GRADE BREAK CONC. CONCRETE SSC START SMOOTH CURVE ESC END SMOOTH CURVE S START E END o am0 O moC, U �9 un V)w�N � 6 f6 -200 T U o 1fl 0) O U j Z pN c\I n w O N m W ISA Z � n N O 90 O SHEET [ OF 1 9 P u`M c L 14H, Signature C.3 AREA CALCULATIONS TOTALPROPOSED IMPERVIOUS SURFACE AREA: 145 SF PROPOSED PERMEABLE PAVERS AREA: 1135 SF PERCENTAGE OF CATCHMENT AREA: 7.e% LEGEND DAREA OF BIORETENTION BASIN • • • • • • . ACCESSIBLE PATH OF TRAVEL EG EXISTING GRADE EP EDGE OF PAVEMENT FL FLOWUNE FG FINISH GRADE SW SIDEWALK SURFACE TC TOPOFCURB DESIGN ELEVATION �X)0f= .5.44x. EXIST ELEVATION Bankof America "01 Homestead Road New Store 21020 Homestead Road Cupertino, CA 95014 SERIAL NUMBER: CA NRSP VERSION: 2.0 BULLETIN: 2017-2 2101 Webster Street Suite 2000 111.1-; 0A 94612 Gensler Telephone 510.625.7400 Facsimile 5IO.625.7499 Pavement Engineering inc. 0 You can ride on our reputation c—. olr saassaoamer4oDms. simaa Sen LWa ObLSPa CA 9.TJOlam16 B6S781-1365 Pavement E.&.A, lnc. AM: JormlhanE IMM, Pmjcct hlarmg, 3920 Cypmaa Ddw, Suit, 3 Peial— CA 9,1954 T: 707-769-5330 E-mail:jorcsflcm. dPavcmrntenginecrmg— Engiaea ofR=M: Jouph L. Ririe, PJE Uxme:CA52735 Ep. 17/31r2018 J0ISaD ey c 01 512512017JRE NIPW Flowing Revievl ' Protect Name Bank of Amedra-Homestead Road tlPro,.et Numeer ```Prototype wyeut [Desc4ptlon EXTERIOR SITE IMPROVEMENTS {sc ASSHOWN SHEET C.1 020150ensler