Loading...
B-2017-1750 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO:B-2017-1750 22204 VIA CAMINO CT CUPERTINO,CA 95014-1032(326 46 008) CLEAN SOLAR INC SAN JOSE,CA 95112 OWNER'S NAME: SCHWARTZ ROBERTA B AND MARTIN M TRUSTEE DATE ISSUED: 10/11/2017 OWNER'S PHONE:408-739-5529 PHONE NO:(408)217-8876 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class C-10 Lic.#910849 Contractor CLEAN SOLAR INC Date 02/28/2018 X BLDG X ELECT _PLUMB MECH X RESIDENTIAL_COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9(commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. JOB DESCRIPTION: (N) 15 PANEL ROOF MOUNTED PV SYSTEM(5.03 KW);(N)LOAD I here, affirm under penalty of perjury one of the following two declarations: CENTER(60 AMPS) 0 1 I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor lode,for the f Te ance of the work for which this permit is issued. fir., have and will maintain Worker's Compensation Insurance,as provided for by •Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$17738.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction,and hereby authorize 326 46 008 representatives of this city to enter upon the above mentioned property for . inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments,costs,and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally,the appl'-a t understands a • ill c.i .ly with all non-point source regulations ser e Cupertino • .al Cod:,Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. - le0411111111P' ignetj' 4 ".-X.ei — Date 10/11/2017 Issued by:AbbyAyende 444 ARAfiginge Date: 10/11/2017 I hereby off rm that I am exempt from the Contractor's License Law for one of the RE-ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed.If a roof is • 1. I,as owner of the property,or my employees with wages as their sole installed without first obtaining an inspection,I agree to remove all new materials for compensation,will do the work,and the structure is not intended or offered for inspection. sale(Sec.7044,Business&Professions Code) 2. ;I;is owner of the property,am exclusively contracting with licensed Signature of Applicant: ' ,contractors to construct the project(Sec,7044,Business&Professions Code). Date: 10/11/2017 is I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1..' .,I ihave and will maintain a Certificate of Consent to self-insure for Worker's ..Compensation,as provided for by Section 3700 of the Labor Code,for the , ,!performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 1 2. :I lhave and will maintain Worker's Compensation Insurance,as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the •i :Section 3700 of the Labor Code,for the performance of the work for which this California Health&Safety Code,Sections 25505,25533,and 25534. I will ,permit is issued. maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the 3. 'I certify that in the performance of the work for which this permit is issued,I Health&Safety Cade,Section 25532(a)should I store or handle hazardous hall not employ any person in any manner so as to become subject to the material. Additionally,should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Ar•:Air I uality mania!: • t District I Worker's Compensation laws of California. If,after making this certificate of will maintain compliance with the Cupermo nicipal Cod• " hap er 9.12 and ',exemption,I become subject to the Worker's Compensation provisions of the the Health&Safety Code Se'tions.5505 25533,:nd 534. Labor Code,I must forthwith comply with such provisions or this permit shall be deemed revoked. 0''5ner or authorized agent: - d ,i r- AM APPLICANT CERTIFICATION Date:10/11/2017 I certify that I have read this application and state that the above information is •Amen!WAR correct.I•agree to comply with all city and county ordinances and state laws I hereby affirm that theMiii�"',struction lending agency for the performance relating to building construction,and hereby authorize representatives of this city of work's for which this per.I is issued(Sec.3097,Civ C.) to enter upon the above mentioned property for inspection purposes. (We)agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments,,costs,and expenses which may accrue against said City in Lender's Address consequence;of the granting of this permit. Additionally,the applicant understands and will,comply with all non-point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION . Code,Section 9.18. I understand my plans shall be used as public records. Licensed Signature Date 10/11/2017 !professional 3-wRs - 11S0 (.....\4,1,./ ALTERNATIVE ENERGY PERMIT APPLICATION AE ' COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION /4"z,,9s 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 (408)777-3228•FAX(408)777-3333•buildinq(a.cupertino.orq CUPERTINO PROJECT ADDRESSA:2190 14a_...„62/2„7/,„?D ` • APN# ` •& ?6 )O OWNER NAME/ez % Cr a r HONE�`�7 / 7 �MAIL /29a/-2 Ar� ec®v , STREET ADDRESS / S IP �f A //_1 FAX s--------" d;or CONTACT NAME E ® S ...„,---/7 7 6D --fig r Emshne/f�'Cka,,?sdac,�n/,,L_ STREET ADDRESS AK /62v/ //rte/ G] CITY,STATE, IP 76wFAX ❑OWNER 0 OWNER-BUILDER 0 OWNER AGENT CONTRACTOR 0 CONTRACTOR AGENT 0 ARCHITECT 0 ENGINEER 0 DEVELOPER 0 TENANT CONTRACTORNAM / /_42 f LIC9$E „7 LICENTYP$� BUS.LIC3/337 COMPANY NAME( ��J(('� / `UJ/E-MAIL C,G`- � FAX -7------ (.6N AX� va4 STREET ADDRESS ,/ 9ç' / /l arm/I ?c/Q//� CITY,STATE,ZJP gI/, PHONE ?CO�f�t� ARCHITECT/ENGINEER NAM ( I LI'CENSE NUMBER ` BUS.LIC# COMPANY E-MAIL FAX REET ADDRESS CITY,STATE,ZIP PHONE USE OF SFD or Duplex 0 Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes 1NoI FLOOD ZONE ❑ Yes......42-Nr SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTS(COMMERCIAL ONLY): o O 3 TOTAL VALUATION DESCRIPTION OF WORK //b6/2?-,€,- 2 /' 7°., . 0.3 kai3O I, irt) avvT [tad cevki RECEIVED B--, •13 �, By my signature below,I certify to each of the folio Ing: am the property owner or autho -. •I,-nt to act,n the property'owner's behalf. I have lead this application and the information I have provided is orrec I have read the Description. ' ork•,:verify' s accurate. I agree to comply with all applicable local ordinances and state laws relating t. :.• •ng co to, ion. I authorize re,•resentati s of -.-rtino t. er the above-identified/ property forinspection'purposes. idV Signature of Applicant/Agent: Date: ! 77 7/ri -.' 'NTAL INFORMATIO ' QU a .. ',OFFICE USE'ONLY a ' _ ' ` ,❑4OVER-THE -COUNTERy . , '0 EXPRESS $ j". a i ❑ x ,STANDARD ,1 . ', s v aW ❑ LARGE t . fix. ❑' ,MAJOR ^vii PVApp 2011.doc revised 03/16/11 SMOKE / CARBON MONOXIDEIIALARMS LL,„ . OWNER CERTIFICATE OF COMPLIANCEutis o COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION ��, T � 4;3 10300 TORRE AVENUE•CUPERTINO,CA 9501255 (408)777-3228•FAX(408)777-3333•buildinqacugertino.orq PERMIT C .NNOT..BE FINALE])UNTIL THIS CERTIFICATE..FIAS.BEtN COMMPLETED,SIGNED,AND RETURNED TO THE BUILDING DIVISION PURPOSE This affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2016 CRC Section R314,R315,2016 CBC Sections 420.i0 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi-family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations,or repairs to existing dwelling units exceeds $1000 00, CRC Section R314,R315, and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations AREA j SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the X X bedroom(s)-(Smoke alarms shall not be located within 3 feet of bathroom door) On every level of a dwelling unit including basements and habitable attics j X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel-burning appliances and that do not have an attached garage. Carbon monoxide alarms combined With smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply In dwelling units with no commercial power supply, alann(s)may be solely battery operaijed. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic,basement or crawl space.Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above-referenced property,I hereby certify that the alarms)referenced above has/have ben installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms specified below have beer tested and are operational, as of the date signed below Address: T2r,244V �,�,,,•� 1 i Permit No. 13'201-7- �.-750 Specify Number of Alarms #Smoke Alarms I I #Carbon Monoxide Detectors I have read and agree to comply with the terms and conditions of this statement Owner(or Owner Agent's)Name: y�� C t � a t7 I"1-4-7 c�,v.00,-1-z. Signature . . -> Date: + Contractor Name: ,{ �l e_n" diol Signature . . Lic.# ?fv �q9 Date: Smoke and COform.doc revised 01/10/2017 JPH G-1 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029LICENSE HOLDER'S SIGNATURE CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com AERIAL MAP PARCEL MAP VICINITY MAP NTS NTS NTS INSTALLATION OF (15) LG ELECTRONICS LG335N1C-A5 MODULES & (15) ENPHASE IQ6PLUS-72-2-US (240V) MICROINVERTER(S) STC RATING: 5.03 KW DC CEC RATING: 4.53 KW AC OCCUPANCY TYPE: R-3 CONSTRUCTION TYPE: V-B AHJ: CITY OF CUPERTINO APN: 326-46-008 PROJECT VALUATION: $17,738.00 G-1 SCOPE OF WORK; SHEET INDEX; VICINITY MAP G-2 NOTES; PROPERTY PLAN G-3 ROOF PLAN; EQUIPMENT LOCATIONS S-1 ROOF FRAMING PLAN; ELEVATIONS; ATTACHMENT DETAILS E-1 ELECTRICAL LINE DIAGRAM E-2 ELECTRICAL CALCULATIONS F-1 SIGNAGE Z-1+ SPECIFICATIONS SCOPE OF WORK SHEET INDEX SCHWARTZ, ROBERTA & MARTY 5.03 kW DC SOLAR PHOTOVOLTAIC SYSTEM 22204 VIA CAMINO CT., CUPERTINO, CA 95014 Phuong Devries 10/11/17 10/11/17 B-2017-1750 Jasmine Archbold JPH G-2 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029SCALE: 1/16" = 1'-0" LICENSE HOLDER'S SIGNATURE CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com BACK OF RESIDENCE FRONT OF RESIDENCE PROPERTY PLAN PROPERTY LINE EXISTING RESIDENCE NOTES ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: · 2016 CBC / 2015 IBC · 2016 CRC / 2015 IRC · 2016 CEC / 2014 NEC · 2016 CMC / 2015 UMC · 2016 CPC / 2015 UPC · 2016 CFC / 2015 IFC · 2016 BUILDING ENERGY EFFICIENCY STANDARDS · 2016 CALIFORNIA ENERGY CODE TITLE 24 · 2016 CALIFORNIA HEALTH AND SAFETY CODE · WHERE APPLICABLE, RULES OF THE PUBLIC UTILITIES COMMISSION REGARDING SAFETY AND RELIABILITY · THE AUTHORITY HAVING JURISDICTION · MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS · CEC ARTICLE 690 · CFC ARTICLE 605.11 · IEEE STANDARD 929 · UL STANDARD 1741 · OSHA 29 CFR 1910.269 · THE AUTHORITY HAVING JURISDICTION GOVERNING CODES 1. DC WIRING METHODS SHALL NOT BE INSTALLED WITHIN 10" OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE COVERED BY THE PV MODULES AND EQUIPMENT (CEC 690.31(G)) 2. AN ACCESS POINT SHALL BE PROVIDED THAT DOES NOT PLACE THE GROUND LADDER OVER OPENINGS SUCH AS WINDOWS OR DOORS ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION AND IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS (CRC R324.7.1) 3. ALL EQUIPMENT AND ASSOCIATED CONNECTIONS OF INVERTERS, MODULES, PV SOURCE CIRCUITS, BATTERY CONNECTIONS, ETC. AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONNEL (CEC 690.4(C)) 4. RAPID SHUTDOWN REQUIREMENTS: PV SYSTEMS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION. PV SYSTEM CONDUCTORS OF MORE THAN 5 FT INSIDE A BUILDING, OR MORE THAN 10 FT FROM A PV ARRAY, SHALL BE LIMITED TO NOT MORE THAN 30 VOLTS AND 240 VA WITHIN 10 SECONDS OF RAPID SHUTDOWN INITIATION, IN ACCORDANCE WITH CEC 690.12 DRIVEWAYVIA CAMI NO CT. 136'-11" 48'-4" 140'-0" 28'-2" 62'-5" 54'-10" 58'-6" 48'-1" 7'-3" Phuong Devries 10/11/17 PVLC MP JB JPH G-3 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com MP PVLC SERVICE POINT & UTILITY METERING DEDICATED PV LOAD CENTER CONDUIT RUN FIRE ACCESS POINT FOR ACCESS LADDER PER CFC 605.11.1.1 (15) (N) SOLAR MODULES PAIRED WITH (15) (N) MICROINVERTERS TO BE MOUNTED UNDER ARRAY PITCH: 18° AZIMUTH: 177° TOTAL AREA OF ARRAY: 277 FT² ROOF PLAN SCALE: 3/32" = 1'-0" EQUIPMENT LEGEND JB JUNCTION BOX (N) CONDUIT (N) PV LOAD CENTER (E) MAIN SERVICE PANEL LICENSE HOLDER'S SIGNATURE ROOF VENTS, OBSTRUCTIONS EXISTING RESIDENCE 1ST STORY COMPOSITION SHINGLE ROOF CONDUIT TO BE RUN ON CONDUIT BLOCKS MIN. 1" ABOVE ROOF SURFACE, CLOSE TO RIDGE LINES, AND UNDER EAVES; DC CONDUIT TO BE LABELED AT MAX 10' INTERVALS CONDUIT RUNS ARE APPROXIMATE AND ARE TO BE DETERMINED IN THE FIELD BY THE INSTALLERS (E) CHIMNEY 45" 72" Phuong Devries 10/11/17 (1) 5/16" x 4-3/4" SS LAG BOLT MIN. 2-1/2" EMBEDMENT FLASHFOOT-2 ALUMINUM FLASHING WITH INTEGRATED RUBBER BUSHING CAPFOOT NEOPRENE BONDED SEALING WASHER GROUNDING MODULE CLAMP IRONRIDGE XR10 RAIL JPH S-1 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029IRONRIDGE XR10 RAIL LICENSE HOLDER'S SIGNATURE CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com FOOTINGS @ MAX. 72" OC SCALE: 3/32" = 1'-0" NTSNTS ELEVATION DETAIL ELEVATION DETAIL - VAULTED SECTION PARTIAL FRAMING PLAN COMPOSITION SHINGLE 24" EAVE OVERHANG WIND BRACE 2" x 4" x 5' EXTERIOR WALLS 3" - 6" VAULTED RAFTERS 2" x 6" @ 24" OC WEIGHT CALCULATIONS ATTACHMENT DETAIL NTS RAFTERS 2" x 6" @ 24" OC RAFTERS 2" x 6" @ 24" OC 58'-4" 19'-2" COMPOSITION SHINGLE 24" EAVE OVERHANG VAULTED RAFTERS 2" x 6" @ 24" OC EXTERIOR WALLS 3" - 6" RIDGE BEAM 2" x 6" COLLAR TIE @ 48" RAFTERS 2" x 6" @ 24" OC CROSS BEAM @ 10'-0" SPAN @ 10' SPAN @ 10' LOAD BEARING WALL @ 12'-0" Phuong Devries 10/11/17 UTILITY SERVICE 120/240V 1 ɸ (E) MAIN METER (E) GENERAL ELECTRIC 125A SERVICE PANEL (E) 125A MAIN BREAKER G (N) JBOX NEMA 3R G [A] WIRES IN FREE AIR * (2) #12 AWG WIRE IN ENGAGE Q-CABLE UV RATED SHEATHING [B] 1/2" EMT CONDUIT * (4) #10 AWG THWN-2 WIRE (1) #8 AWG THWN-2 EGC BRANCH CIRCUIT 1: (8) LG ELECTRONICS LG335N1C-A5 MODULES PAIRED WITH (8) ENPHASE IQ6PLUS-72-2-US (240V) MICROINVERTERS (E) LOADS G (N) PV OCPD 2P 20A ENVOY-IQ MONITOR (N) OCPD 1P 5A CT (N) PV OCPD 2P 20A [C] 3/4" EMT CONDUIT (3) #8 AWG THWN-2 WIRE (1) #8 AWG THWN-2 EGC BRANCH CIRCUIT 2: (7) LG ELECTRONICS LG335N1C-A5 MODULES PAIRED WITH (7) ENPHASE IQ6PLUS-72-2-US (240V) MICROINVERTERS ** #6 AWG BARE COPPER EGC (N) 60A 240V PV LOAD CENTER MICROINVERTER AC COMBINER WITH INTEGRATED MONITORING, NEMA-3R (N) #6 GROUND ROD + (N) #6 SUPPL. GROUND ROD + (N)#6 WATER PIPE BOND JPH E-1 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029LICENSE HOLDER'S SIGNATURE CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com ELECTRICAL LINE DIAGRAM NOTES: · MODULES ARE BONDED TO RAIL USING UL 2703 RATED BONDING SYSTEM - INTEGRATED BONDING MID-CLAMPS + DIRECT-BURIAL LAY-IN-LUGS; SEE ATTACHED FOR SPECIFICATIONS · WHEN UTILIZING THE 120% RULE, BACKFED PV BREAKERS WILL BE INSTALLED AT OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. A PERMANENT WARNING LABEL TO BE INSTALLED PER SYSTEM SIGNAGE, SHEET F-1 · PV DC SYSTEM IS UNGROUNDED · BACKFED PV BREAKER WILL BE INSTALLED AT OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. A PERMANENT WARNING LABEL TO BE INSTALLED PER SYSTEM SIGNAGE, SHEET F-1 · WHEN PRESENT, THE GEC TO BE CONTINUOUS AS PER CEC 250.64(C) AND TO TERMINATE AT A GROUNDING ELECTRODE · FOR ALL SYSTEMS OVER 250V, CONCENTRIC AND ECCENTRIC KNOCKOUTS SHALL BE PROPERLY BONDED · INVERTER(S) TO BE COMPLIANT WITH UL 1741 SUPPLEMENT A * THE ENPHASE IQ MICROINVERTER SYSTEM USES A DG TYPE CABLE AND CONTAINS ONLY TWO #12 AWG LINE CONDUCTORS. THE Q CABLE MALE CONNECTORS PLUG DIRECTLY INTO THE IQ MICROS, WHOSE DOUBLE INSULATION RATING REQUIRES NO NEUTRAL OR GROUND CONDUCTORS; LINE-TO-LINE COMMUNICATIONS INSTEAD OF THE NEUTRAL IS USED TO DETERMINE GRID VALUES. THIS FUNCTIONALITY IS PART OF ITS UL LISTING. ** GROUND PATH IS AS FOLLOWS: THE IQ 6 MICRO AND THE IQ 6+ MICRO DO NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS (GEC) OR EQUIPMENT GROUNDING CONDUCTORS (EGC); MICROINVERTER MOUNTING BRACKET IS BONDED VIA UL 2703 HARDWARE CONNECTION TO RACKING; INTEGRATED BONDING CLAMPS BOND MODULE FRAMES TO RACKING; RACKING IS BONDED TO BARE WIRE EGC VIA UL 2703 LISTED HARDWARE 2P 25A Phuong Devries 10/11/17 JPH E-2 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029LICENSE HOLDER'S SIGNATURE CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com ELECTRICAL CALCULATIONS 25 A21.9 Phuong Devries 10/11/17 JPH F-1 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com LICENSE HOLDER'S SIGNATURE CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: 22204 VIA CAMINO CT., CUPERTINO, CA 95014 PV SOLAR ARRAY K PV LOAD CENTER SIGNAGE FORMAT: ALL LETTERS SHALL BE CAPITALIZED, 3/8" WHITE LETTERING ON RED BACKGROUND, ARIAL OR SIMILAR FONT, NON-BOLD; REFLECTIVE, ON WEATHER- RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING) WILL BE USED; DURABLE ADHESIVE MATERIALS MEET THIS REQUIREMENT. TO BE PLACED JUNCTION BOXES, DISCONNECTS, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES; MARKING SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES EVERY 10 FEET, WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OR BARRIERS: WARNING: PHOTOVOLTAIC POWER SOURCE CAUTION - PHOTOVOLTAIC AC DISCONNECT PV SYSTEM DC DISCONNECT RATED MAX POWER-POINT CURRENT - 9.83 A RATED POWER-POINT VOLTAGE - 34.1 V MAXIMUM SYSTEM VOLTAGE - 46.7 V SHORT CIRCUIT CURRENT - 13.11 A WARNING DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT: 17.6 A NORMAL OPERATING AC VOLTAGE: 240 V B TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE AND SUBPANEL TIE-IN LOCATIONS: TO BE INSTALLED AT THE MAIN SERVICE PANEL, AC DISCONNECT, AND SUBPANEL TIE-IN LOCATIONS: TO BE INSTALLED NEXT TO THE PV BREAKER AT THE MAIN ELECTRICAL SERVICE AND SUBPANEL TIE-IN LOCATIONS: C A WARNING: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED TO BE INSTALLED AT THE INVERTER (GROUNDED SYSTEMS, NEAR GROUND FAULT INDICATOR): F TO BE INSTALLED AT THE DC DISCONNECT: TO BE INSTALLED AT THE AC DISCONNECT: WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED IN THE OPEN POSITION TO BE INSTALLED AT THE JUNCTION BOXES, INVERTER, AND DC DISCONNECT (UNGROUNDED SYSTEMS): G D I J ELECTRIC SHOCK HAZARD NO USER SERVICEABLE PARTS INSIDE CONTACT AUTHORIZED SERVICER FOR ASSISTANCE TO BE INSTALLED AT THE JUNCTION BOXES: E WARNING - INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE TO BE INSTALLED AT THE ELECTRICAL SERVICE: A DIRECTORY PLACARD INDICATING LOCATION OF SERVICE AND PV SYSTEM DISCONNECTING MEANS IF NOT AT THE SAME LOCATION WARNING: ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION TO BE INSTALLED AT THE DC DISCONNECT: H SIGNAGE PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN TO BE PLACED AT THE SERVICE DISCONNECT: L SIGNAGE LOCATIONS - MICROINVERTER SYSTEM PV ARRAY JUNCTION BOX PV LOAD CENTER (WHEN PRESENT) AC DISCONNECT (WHEN PRESENT) PV METER (WHEN PRESENT) MAIN SERVICE PANEL E SUBPANEL (WHEN PRESENT) A A A BC C C C D DDD I K L SERVICE POINT & UTILITY METERING Phuong Devries 10/11/17 PHOTOVOLTAIC MODULE SPECIFICATIONS JPH Z-1 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com Phuong Devries 10/11/17 INVERTER SPECIFICATIONS JPH Z-2.1 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com Phuong Devries 10/11/17 UL 1741 SA COMPLIANCETRUNK CABLE SPECIFICATIONS JPH Z-2.2 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com Phuong Devries 10/11/17 FOOTING SPECIFICATIONS JPH Z-3 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com Phuong Devries 10/11/17 JPH Z-4.1 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029RACKING SPECIFICATIONS CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com Phuong Devries 10/11/17 JPH Z-4.2 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com RACKING ENGINEERINGPhuong Devries 10/11/17 JPH Z-4.3 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com RACKING FIRE RATINGRACKING ENGINEERING Phuong Devries 10/11/17 JPH Z-5.1 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029GROUNDING & BONDING SPECIFICATIONS CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com Phuong Devries 10/11/17 JPH Z-5.2 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029GROUNDING & BONDING SPECIFICATIONS CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com Phuong Devries 10/11/17 JPH Z-6.1 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com PV LOAD CENTER SPECIFICATIONSPhuong Devries 10/11/17 JPH Z-6.2 SHEET NUMBER: DRAWN BY: DATE: REV: 10/6/17 10/6/17PROJECT:CS PROJECT ID: 3011-ZSCHWARTZ, ROBERTA & MARTY22204 VIA CAMINO CT.,CUPERTINO, CA 95014(408) 739-55029CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com MONITORING SPECIFICATIONSPhuong Devries 10/11/17