Loading...
14090011 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10383 TONITA WAY CONTRACTOR:SOLARCITY PERMIT NO: 14090011 OWNER'S NAME: SAN MATEQ CA 94402 PHONE NO:(650)638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL E] COMMERCIAL E] INSTALL 9 ROOF TOP,FLUSH MOUNTED PV PANELS, License ClassC�t .,,b Lic.# 2.295 7 Contractor t�j �GIY�_t t`� Date o�0 bj�( KW I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$5000 1 have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:35914006.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION 1 certify that 1 have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.1 agree to comply with all city and county ordinances and state laws relating WITHIN 180 D IT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 OM LA LLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit. Ad ionally,the applicant understands and will comply Date: with all non-point RE-ROOFS: Signature Date L? 4/ i© �Z I Lf All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,l agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous 1 have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay ea Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cu a tino M icipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code, Date: C')71 03Z 14 permit is issued. 1 certify that in the performance of the work for which this permit is issued,1 shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,1 CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,1 must 1 hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. 1 agree to comply with al I city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION O COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 AE CUPERTINO 1 (408)777-3228• FAX (408)777-3333• building(Qcupertino.org \ PROJECT ADDRESS y 0n 3 Y 5 TvI,�I c j- Oat APN# _ G oz OWNER NAME _// (' FAX 10.3X3 1on1 a C ,�X{ina,Cil 7-5-01 Ll CONTACT NAME �/� E-MAIL Kl (-IUay',I v'"I-L(1�,"CC 1 �CI�fA-Yyh�C.�1�i (�5�)`IY?-('l 73o JCIYl II' \ STREET ADDRESS 3ql FOSC,,��i t� ��. CITY,STATE, ZIP C�1)1 /j�`JJ/I�(` FAX ❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT �CONIRACTOR ❑CONTRACTOR AGENT ❑I ARCHITFCIT 1❑1'ETNG ENGINEER ER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME 'S"1'y /-? ; .� -7 LICENSE NUMBER �p r+��G/1 Cwlc,(E ,C-LA BUS.LIC# p , COMPANY NAME S 1���' 1�� E-MAIL O�1 -1 aiCJ FAX 6 STREET ADDRESS 3`11 t��/�-{`1,/7 11 �I V j, CITY,STATE,ZIP Fo stly C J1 I C. /1 lllq q o z� PHONE 6 5U _ ARCHITECT/ENGINEER NAME 1 �- I l LICENSE NUMBER C I ;J'` (T BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF ❑ SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUTURF ❑ Commercial URBAN INTERFACE AREA ❑ Yes El No FLOOD ZONE El Yes ❑ NO SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS KILOWATTS(COMMERCIAL ONLY): rJ` z Q TOTAL VALUATION: DESCRIPTION OF WORK L I IC C �By my signature below,I certify to each of the following: I t pr rty owner or authorize ge ct on the property owner's b I have read this application and the information I have provided is correct. a re e Description of Work and verify it is accurate. I agree to ply with all applicable local ordinances and state laws relating to building construction. Date: SUPP TAIL ION REQUIRED OFFICE USE ONLY &W ER-THE-COUNTER a. El' EXPRESS V x ❑ STANDARD V a ❑ LARGE c. ❑ MAJOR PIlApp_201].doe revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR— BUILDING DIVISION ADDRESS: 10383 TONITA WAY DATE: 09/03/2014 REVIEWED BY: MELISSA APN: 359 14 006 BP#: , 6)?66)// `VALUATION: 1$5,000 PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RES SE: PERMIT TYPE: WORK INSTALL 9 ROOF TOP FLUSH MOUNTED PV PANELS 2.295 kW SCOPE F-1 Ll NOTE:This estimate does not include fees due to other Departments(i.e.Planning,Public Works, Fire,Sanitary Sewer District,School District,etc. . These.fees are based on the prelimina information available and are only an estimate. Contact the De t or addn'l info. FEE ITEMS (Fee Resoltiilion 11-053 Fff %Lj31 FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 0 # Alternative Energy System Suppl. PC Fee: Q Reg. 0 OT 0.0 1 hrs $0.00 $236.007IPHOTovREs Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Feer Reg. 0 OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 0 Work Without Permit? Q Yes (D No $0.00 0 Advanced Planning Fee: $0.00 Select a Non-Residential G) Building or Structure 0 i Stroup, Motion Fee: 1BSEISMICR $0.65 Select an Administrative Item B1d�4 Stds Commission Fee: 1BCBSC $1.00 SUBTOTALS: $1.65 $236.00 TOTAL FEE: $237.65 Revised: 08/20/2014 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING FLASHING WILL BE PAINTED TO MATCH EXTERIOR AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE CONC CONCRETE HAZARDS PER ART. 690.17. 0114 DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE ;As, EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY ^yt (E) EXISTING PHASE AND SYSTEM PER ART. 210.5. E EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY-RECOGNIZED TESTING FSB Fire Set-Back LABORATORY SHALL LIST ALL EQUIPMENT IN GALV GALVANIZED COMPLIANCE WITH ART. 110.3. GEC GROUNDING ELECTRODE CONDUCTOR 4. CIRCUITS OVER 250V TO GROUND SHALL GND GROUND COMPLY WITH ART. 250.97, 250.92(B) HDG HOT DIPPED GALVANIZED 5. DC CONDUCTORS EITHER DO NOT ENTER °bssetot �'F I CURRENT BUILDING OR ARE RUN IN METALLIC RACEWAYS OR fj�A cha �9.�� �- UOF,o,� Imp CURRENT AT MAX POWER ENCLOSURES TO THE FIRST ACCESSIBLE DC 1/11,9 r&fr° '�90 co Q'soec f °_,. '.',� <RT��RT,�F Isc SHORT CIRCUIT CURRENT DISCONNECTING MEANS PER ART. 690.31(E). st '� O �1? kVA KILOVOLT AMPERE 6. ALL WIRES SHALL BE PROVIDED WITH STIR Vie, sn?r� h° 5e/ /n vt Jr�� s�✓/(� kW KILOWATT RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY 01' '4q0',h �p fo °/7s '�,7/ ST LBW LOAD BEARING WALL UL LISTING. ro -�!;- `s �a%fr "tae a�'fu�.h�'kP MIN MINIMUM 7. MODULE FRAMES SHALL BE GROUNDED AT ``'o, tort °With or to to,h ptat (N) NEW UL-LISTED LOCATION PROVIDED BY THE p 7S °��'� �,c; seu0�; °� �ek�a,,the r' '� CUPERTINC) YLU`r PLANS NEUT NEUTRAL MANUFACTURER USING UL LISTED GROUNDING `��'�!i y�_ arc 't10 n�O%l% y ! x Building Department NTS NOT TO SCALE HARDWARE. `I`4 '`)`rp};7 �'a/°fns Sy cra! �_ i CHECKED BY OC ON CENTER 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE once theLl;�<<ty E`., -� s PL PROPERTY LINE BONDED WITH EQUIPMENT GROUND CONDUCTORS AND °r`Stdte,�tiCnOT `` =� 5€P 0 3 20114 GATE 76 POI POINT OF INTERCONNECTION GROUNDED AT THE MAIN ELECTRIC PANEL. �`�� REVIEINEC FOR CODE COMPLIANCE PV PHOTOVOLTAIC 9. THE DC GROUNDING ELECTRODE CONDUCTOR O PLANNING DEPT. SCH SCHEDULE SHALL BE SIZED ACCORDING TO ART. 250.166(B) & j / .ieviewed By SS STAINLESS STEEL 690.47. DATE STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY msw.. i:�.vr. V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV2 SITE PLAN PV1 COVER SHEET PV3 STRUCTURAL RECEIVED PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES PV5 THREE LINE DIAGftt 3 2014 Cutsheets Attached t� CA # 888104 1. THIS SYSTEM IS GRID-INTERTIED VIA A - C-10 UL-LISTED POWER-CONDITIONING INVERTER. • BY 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. 4. ALL WORK TO BE DONE TO THE 2013 J C/LOL?001/ MODULE GROUNDING METHOD: ZEP SOLAR CALIFORNIA BUILDING CODE AND THE 2013 AHJ: Cupertino CALIFORNIA RESIDENTIAL CODE. REV BY DATE COMMENTS 5. ALL ELECTRICAL WORK SHALL COMPLY WITH PEVA NAME GATE COMMENTS THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. UTILITY: Pacific Gas and Electric Company �'1 - - • c • i • • _ _ JB-9503448 0 0 PREIASE D� DEscmpmk DESIGN: , CONFIDENTIAL S — THE INFORMATION HEREIN JOB NUMBERLEUNG, ED LEUNG RESIDENCE Kevin Groth CONTAINOF ED SHALL NOT YONE CE USED FOR THE MOUNTING i1�olarCity NOR SHTALL IT BE DISCLOSED N WHOLE ORPT SOLARCITY CIN MOUNn"G SYsra: 10383 TO N I TA WAY 2.2 9 5 K W P V ARRAY '' ZEP Mighty Hook o`1 PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: C U P E R TI N O, CA 9 5014 /trt,r U ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (9) Advantage Module 3055 pG0"ie"Way SOIARCITY EQUIPMENT, WITHOUT THE WRITTEN AtViRTER PAGE NAME SHS' FEV' DATE: T:(650)638-1028Son 'CA (650)638-1029 PER►ussloN of SOLARCITY INC. ABB PVI-3.0-OUTD-S-US-Z-A (408) 204-7168 COVER SHEET PV 1 a 8/22/2014 (SNIT-SOL-CITY(765-2489)www.golarcitycorn PITCH: 14 ARRAY PITCH:14 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Flat Cement Tile STORY: 1 Story 0 CA 00CA (E)DRIVEWAY � 0 0 LEGEN D Q (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS Front Of HouseC AC DISCONNECT & WARNING LABELS LEODC JUNCTION/COMBINER BOX & LABELS t> CUPERTINO D DISTRIBUTION PANEL & LABELS Building Departrnent I Lc LOAD CENTER & WARNING LABELS 6;� ... _,- SEP 0 3 201 3' FSB 3' FSB tEVIEWEG PCR CODE COMPLIANCE DEDICATED PV SYSTEM METER y � O Reviewed B V� �, O STANDOFF LOCATIONS T KD: Ln CONDUIT RUN ON EXTERIOR 0 0 0 0 0 W — 0 -- CONDUIT RUN ON INTERIOR GATE/FENCE OInv A R 0 HEAT PRODUCING VENTS ARE RED g r._ lk ;�J INTERIOR EQUIPMENT IS DASHED TOTAL ARRAY AREA (SF): 162 SITE PLAN NScale: 3/32" = 1' TOTAL ROOF AREA (SF): 3577 w E TOTAL ARRAY AREA IS m 4.52 O 1' 10' 21' PERCENT OF TOTAL ROOF AREA s CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER PREMISE OWNER: DESCRIPTION. DESIGN. CONTAINED SHALL NOT BE USED FOR 1liE _-_ ""-950344" 00 ���a� ■ LEUNG, ED I Fl1NG RESIDENCE Kevin Groth i,\�OI�r�I�" BENEFIT OF ANYONE EXCEPT SOLARGTY INC., MOUNTING SYSTEM: 'Wk rs NOR SHALL IT BE DISCLOSED IN WHOLE T IN ZEP Mighty Hook 10383 TONITA WAY 2.295 KW PV ARRAY �f v PART IZ OTHERS OUTSIDE THE RECIPIENT'S MODULES: C U P E R TI N 0, C A 95014 1t,,�,>� ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (9) Advantage Module 3055 Clearrkri Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PAGE NAME SHS- �' DATE. T:(650 )Son Mateo, CA 9W2 8 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB PVI-3.0—OUTD—S—US—Z—A (408) 204-7168 SITE PLAN PV 2 0 8/22/2014 (688)-SOL—CITY(765-2489) www.soIarcNy.com S 1 INSTALLATION ORDER ZEP SPANNER BAR LOCATE RAFTER, MARK RAFTER (E) 2x6 (6) LOCATION, (1) PLACE STANDOFREMOVE F BASE & DRILL (E) 2x4 PILOT HOLES AT THE RAFTER LOCATION. 1'-10" ' '-12) DIA BOLT & NUT CLEAN PAPER AROUND PILOT (1) (2) (�) (3) 2) HOLE. (E) LBW (E) LBW BAR CZEP LAMPER q—ZDIST STANDOFF TO BATTEN HEIGHT. SIDE VIEW O F M P 1 NTS STANDOFF SEAL PILOT HOLES AND BOTTOM A (E) TILE ((4) OF STANDOFF WITH POLYURETHANE (E) ROOF DECKING (5) (4) SEALANT. MPJ X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES 5/16" DIA STAINLESS 5) LAG STANDOFF INTO RAFTER. LANDSCAPE 72" 24" 52" 24" STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES (2-1/2° EMBED, MIN) NOTCH TILE WEATHERING TO FIT PORTRAIT 48" 2011 R5211 2 P (E) RAFTER STAN DOFF 6 AROUND STANDOFF. RAFTER 2X4 @ 24"t OOF AZI 180 ITCH 14 OC ARRAY AZI 180 PITCH 14 STORIES. 1 S 1 7) REINSTALL TILE. C.I. 2x6 @16" OC Flat Cement Tile CUPEYrrvo Building 0epat'nent _1E�.�cr �C- COM—PLlANC'i '1 PREMISE OIYNER. DESCRIPTION: DESIGN. CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER JB-9503448 00 CONTAINED SHALL NOT BE USED FOR THE LEUNG, ED I FLING RESIDENCE Kevin Groth � solarCity.BENEFlT OF ANYONE EXCEPT SOLARaTY INC., MOUNTING SYSIEM: , NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 10383 TONITA WAY 2.295 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH Maou�s: CUPERTINO, CA 95014 y r THE SALE AND USE OF THE RESPECTIVE (9) Advantage Module 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PAGE NAME SHEET: REV: DATE San 02 T:(650)638-1028'F 944 638-1029 PERMISSION OF SOLARaTY INC. ABB PVI-3.0—OUTD—S—US—Z—A (408) 204-7168 STRUCTURAL VIEWS PV 3 a 8/22/2014 (668)-SOL—CITY(765-2489)www.sdarcity.com UPLIFT CALCULATIONS *� 00.12.2014 _.►,:So�a�City. SteekMountTM PV System Ver"037.9 Structural Desian Software iaRc'>r�i.god iiot Ti1�Rod 1 Q4tllt�tlon M PV NO"Nlidb ' Ft 21�wgf E89919RE�law -1 Ado -L Mfrk VMnd110 a�ph _ 2&S-LA li&y - Sow Roof GIbk#4d N� Wycaryt A 17.61f J., - T 1- Wind Fads Kd 0.65 %than 16.6-1 vabdh►P�erare Vh 4h_0.00 ,�(KM Nom ) 3L3-1 119 CUPERTINO wilding Department . . T _ 3 2014 wat... REVIEWED r-0 ISE COMPLIANCE OV Lord 3 Re iewesi B %, � •' �RT IMMLOM Of TySow 500 6'S . "M[. Pofi7R _ Sr M' 's. VV "*Swam d`9Eindalf T-d" M0 in � —AaG3�4�00 PREM DESCRIPTION: DENt AM CONFIDENTIAL- :N7RMC71W HEREIN pe► LEUNG, -- _ LE-UM RES DEUCE , ifevin-froth �ANSRCITY NC., muTM SYSTIY NOR� IT BE° "W OR N ZEP Mighty Hook 10383 TONITA WAY 2.295 KW PV ARRAY i • PART TO OTIfRS OTHE RECIPIENTS %rfv Dia 3053 way ORGANIZATION, EXCECTION IMTM � CU P ER TI N 0, CA 95014 SMARCITr EQU� cn� 9 Advanta a ModuleTTEN PAM� SHEEE REV. DATE Sm Mutm CA 94+02 PERUSSM OF " BB# 408 204-7168 PV 4 a 8/22/2014 ieeej-��(' 2028 489)w �10� ABB PVI-3.0—ouTD—s-us-z-A � ) UPLIFT CALCULATIONS GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number. Inv 1: DC Ungrounded INV 1 —(1)ABB#! PVI-3.0—OUTD—S—US—Z—A BE A —(9)Advantage Module CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:1006140590 AFC f'Inverter, Zigbee 3000W, 277V/24OV/208V, 96%/9 •6%/96% PV Module; 255W, Poly, 60cell, Blck Frame, White Bcksht, ZEP C-10 Overhead Service Entrance INV 2 Voc: 37.7 Vpmax: 30.2 INV 3 Ise AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E) 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 PAR 200A/2P 3 POWER—ONE AURORA PVI-3.0—OUTD—S—US—Z—A (E) LOADS LI 24�„ SolarCity L2 N 2 A 1 20A/2P EGG pC. DC DO NOT ADJUST MIN.ACTIVATION V LTQ AGE A ------------------------------------------------ — GEC ---TN DG DG 15tring(s)Of90n MP1 I I�— B I GND -- EC—'C——————————————————————————— ---'---- -- —E — --—————————————— � I I I N I I EGCIGEC — z z c� --- GEC --� TO 120/240V SINGLE PHASE I UTILITY SERVICE I I I I i UPE€ TING (3uildinG De � s, P tnent REVIEWEis r'OR CODE (',UMPUAN%C'-E reviewed By Voc* = MAX VOC AT MIN TEMP O1 (1)CUTLER—HAMM�R /BQC20250 PV BACKFEED BREAKER A (1)SolarCityy 4 STRING JUNCTION BOX DC Breaker, 20A 2P-50A/112P, 2 Spaces, Quadplex AC 2x2 STRINGS, UNFUSED, GROUNDED —(1)Ground Rod; 5/8' x 8, Copper 1 AWG/10, THWN-2, Block (I)AWG/10, THWN-2, Block Voc* =377.37VDC Isc =9 ADC (2)AWG 110, PV WIRE, Black Voc* =377.37VDC Isc =9 ADC O k(I)AWG /10, THWN-2, Red O (1)AWG /10, THWN-2, Red Vmp =271.8 VDC Imp=8.43 ADC O (1)AWG/10, Solid Bare Copper EGC Vmp =271.8 VDC Imp=8.43 ADC I-L(1)AWG 110, THWN-2, White NEUTRAL Vmp =240VAC Imp=14.5 AAC (1)AWG 11.0, THWN-2,.Green. . EGC. . . -(1)Conduit.Kit.3/4'.EMT . . . . . . .-.(1)AWG /8,.THPM-?,.Greer! . EGC/GEC.-(1)Conduit.Kit;.3/4'.EMT. . . . . . . . . . J B-9 5 0 3 4 4 8 PREMISE O� DESCRIPTION. DESIGN. _ ._ CONFIDENTIAL— THE INFORMATION HEREIN [ZEP B NuueER LEUNG, ED LEUNG RESIDENCE Kevin Groth CONTAINED SHALL NOT E USED FOR THE ,,,Solarc�ty BENEFIT OF ANYONE EXCEPT SOLARCITY INC., UNTING SY TEIk .,: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Mighty Hook 10383 TONITA WAY 2.295 KW PV ARRAYPART To OTHERS OUTSIDE THE RECIPIENTS �J ORGANIZATION, EXCEPT IN CONNECTION WITH DULES; CUPERTINO, CA 95014THE SALE AND USE OF THE RESPECTIVE 9) Advantage Module on M t e, CA.Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN ERTER: PAGE NAVE' GATE T:(650)63& 1028 F(650)638-1029 PERMISSION OF SOLARCITY INC. BB PVI-3.0—OUTD—S—US—Z—A (408) 204-7168 THREE LINE DIAGRAM PV 5 a 8/22/2014 (688)—SOL—CITY(765-2489)www--darcity.com Label Location: Label Location: Label Location: UVARNfNG:PHOTOVOLTAIC POINER SOURCE , PV SYSTEM WARNING DPer CRCCR331.2Per _ •'- DISCONNECT FOR ELECTRIC SHOCK HAZARD " UTILITY OPERATION 690.35(F) THE DC CONDUCTORS OF THIS Label Location: PHOTOVOLTAIC SYSTEM ARE • BE USED WHEN PHOTOVOLTAIC DC D MAY BEOINVERTEENERGIZED UNGROUNDED • IS - Code: CEC DISCONNECT •'1 .14.C.2 Label Location: WARNING ' Per ..- ELECTRIC SHOCK HAZARD Label Location: CEC 690.17 DO NOT TOUCH TERMINALS MAXIMUM POWER- TERMINALS ON BOTH LINE AND POINT CURRENT(Imp)_APer Code: LOAD SIDES MAY BE ENERGIZED MAXIMUM POWERIN THE OPEN POSITION POINT VOLTAGE(Vmp) VCEC 690.53 MAXIMUM SYSTEM V VOLTAGE(Voc) SHORT-CIRCUIT_ CURRENT(Isc) A Label • • WARNING '' Per ..- CEC INVERTER OUTPUT 1 CONNECTION Label Location: DO NOT RELOCATE WARNINGB THIS OVERCURRENT Per Code:dDEVICE ELECTRICAL SHOCK HAZARD 690.17 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITIONLabel L• • DC VOLTAGE IS PHOTOVOLTAIC POINT OF '• ALWAYS PRESENT WHEN INTERCONNECTIONPer SOLAR MODULES ARE Code: EXPOSED TO SUNLIGHT WARNING:ELECTRIC SHOCK 690.54; 690.17 HAZARD.DO NOT TOUCH TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE Label Location: DE-ENERGIZE BOTH SOURCE WARNING AND MAIN BREAKER. Per PV POWER SOURCE Code: MAXIMUM AC ELECTRIC SHOCK HAZARD 690.5(C) OPERATING CURRENT _ A -• IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED V MAXIMUM AC r,/; CONDUCTORS MAY BE OPERATING VOLTAGE UNGROUNDED AND ENERGIZED Label • • Label PHOTOVOLTAIC ACI ''• CAUTION '_ PCode: Disconnect Code: PHOTOVOLTAIC SYSTEM 690.64.13 • • CEC DISCONNECT690.14.C.2 914 CIRCUIT IS BACKFED Combiner b _ B• Conduit(D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Label Location: Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AC _ q • CAUTION • •-• Center OPERATING CURRENTPer Code: DUAL POWER SOURCEPer Code: MAXIMUM ACCEC 690.54SECOND SOURCE IS 1 OPERATING VOLTAGE V PHOTOVOLTAIC SYSTEM • Point of ' • 1 li 1' 1 1 1 • / 1 /' 3055 Cleaview Way San Mateo,C-A 94402 T:(650)638-1028 F050)638-1029 SC CA Label Set i• 1 •1 1 .1 I , 1 SolarCity SleekMountTM - Tile SolarCity SleekMountT"" - Tile The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules aesthetics while minimizing roof disruption and 0 Remove file and locate rafter •Interlock and grounding devices in system UL labor. The elimination of visible rail ends and listed to UL 2703 ® Drill pilot holes of proper diameter for mounting clamps, combined with the addition !;,k, fastener size per NDS section 1.1.3.2 of arra trim and a lower •Interlock and Ground Zep ETL listed to UL 1703 __ y profile all contribute to as"Grounding and Bonding System" • Seal pilot holes with roofing sealant a more visually appealing system. SleekMount utilizes Zep Compatible TM modules with •Ground Zep UL and ETL listed to UL 467 as ® Place tile hook strengthened frames that attach directly to Zep grounding device a Install lags pursuant to NDS section 11.1.3 Solar standoffs,effectively reducing the number with fender washer •Anodized components for corrosion resistance \ of standoffs required, when compared to • Notch underside of tile and reinstall tile conventional rail-based systems. •Applicable for vent spanning functions • Attach Spanner Clamps and tighten firmly in place ® Insert Cam Foot into Spanner Bar and rotate Cam Nut 100 degrees Components ® Place modules Cam Foot A ® Spanner Bar • 3/8"Machine Screw and Nut lop • Spanner Bar Clamp O Tile Hook • Lag Screw(2) B l C j� CUPERlINO F i:y r Building Department r SEP 0 3 2014 E, o REVIEtNED FOR. C ODE G:ON4PIANCE 00 Reviewed By 7 Solar�ity. 'O1 O LISTED SolarCity January 20131 January 2013 SolarCity Advantage Module Electrical Parameters at Standard Test Conditions(STC) The SolarCity Advantage module represents a 60 Cell,ZEP enabled Power Output Pmax W 255 module.The values shown are the most extreme potential values Power Output Tolerances APmax W -0/+5 from SolarCity's portfolio of CEC approved and UL or ETL listed Module Efficiency nm % 15.85 modules. Modules will have a minimum 10 year warranty.The Maximum Power Voltage Vmp V 30.2 module installed will be one of the following: Maximum Power Current Impp A 8.43 Open-circuit voltage Voc V 37.7 Short-circuit current Isc A 9 Trina Solar:TSM255PA05.18 Canadian Solar: CS6P-255PX Values at Standard Test Conditions STC(Air Mass AM1.5,Irradiance 1000W/m',Cell Temperature 25°C). Electrical Parameters at Nominal Operating Cell Temperature (NOCT) Power Output Pmax W 185 Voltage at Pmax Vmpp V 27.4 Current at Pmax Impp A 6.77 Open-circuit voltage Voc V 34.4 Short-circuit current lisc I A 1 7.31 NOCT:Irradiance at 80OW/m2,Ambient Temperature 20°C,Wind Speed 1M/s. Thermal Characteristics Nominal operating cell temperature NOCT °C 46+/-2 Temperature coefficient of Pmax y %/°C -0.43 Temperature coefficient of Voc (3Voc %/°C -0.34 Temperature coefficient of Isc alsc %/°C 0.065 General Characteristics Solar Cells Multicrystaline Frame Aluminum allo black - PE INCA Weight 45.2 lbs (20.5 I . 1;_ Building Qepartment .kt i.�J SEP a 3 2014 REVIEWED FOR CODE COV-PL.:ArgCE Reviewed By .• r�jlfryr, TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE Mono Multi Solutions DIMENSIONS OF PV MODULE TSM-PA05.18 ELECTRICAL DATA @ STC TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 941 mm Peak Power Watts-Pwsx(Wp) 240 245 250 255 260 Power Output Toleronce-Pnr•x J%) 0/+3 0/+3 0/+3 0/+3 0/+3 Maximum Power Voltage-VM (VJ 29.7 30.2 30.3 30.5 30.7 a3x Maximum Power Current-lam(A) 8.10 8.13 8.27 8.36 8.47 TSM - PA05 .18 9S 1zrE - Open Circuit Voltage-Voc(V) 37.3 37.5 37.6 37,7 37.9 °Kr'���x�nr Short Circuit Current-Ise(A) 8.62 8.68 8.85 8.92 9.00 Module Efficiency nm(%1 14.7 15.0 15.3 15.6 15.9 THE TRINAMOUNT MODULE STC:Irradiance 1000 W/m'.Cell Tempera l ure 25°C,Air MOSS AM1.5 accarding to EN 60904-3. average efficiency reduction of 4.5%at 200 W/m'accortling to EN 60904-1. E b g 3 ELECTRICAL DATA @ NOCT TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 60 CELL ELL Maximum Power-Pwsz(Wp) 174 178 181 184 188 Maximum Power Voltoge-Vmp(V) 26.6 26.8 27.0 27.2 27.4 MULTICRYSTALLINEMODULE A A Maximum PowerCurrent-l-(A) 6.55 6.64 6.70 6.77 6.86 WITH TRINAMOUNT FRAME "r Open Circuit Voltage(V)-VocJV) 34.1 34.2 34.3 34.4 34.6 Short Circuit Current(A)-Isc(A) 7.04 7.10 7.25 7.31 7.37 240 26 0 W B,2mm 180 NOCT:Irradiance at 800 w/m'.Ambient Temperature 20°C,wind Speed I m/s. Sock View POWER OUTPUT RANGE Our most versitile product LIQ MECHANICAL DATA Compatible with all major BOS components and system Solorcells Multicrystalline 156 x 156 mm(6 inches) designs Cell orientation 60cells(6x10) 15.9% Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05.1.57 inches) Weight 18.6 kg(41.0 lbs) MAXIMUM EFFICIENCY Glass High transparency salar glass 3.2 mm(0.13 inches) One of the industry's most trusted modules Bocksheet White Over 2 GW sold across all major global markets Frame Bloc k Anodized Al um iniu m All oy with Tri no mau nt Groove 0��y p Field proven performance I-V CURVES OF PV MODULE TSM-245 J-Box IP 65 or IP 67 rated ■ 3% Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), 1100 mm(43.3 inches) POWER OUTPUT GUARANTEE to.. 8m Connector OriginalMC4 _7.- wow/m' Highly reliable due to stringent quality control <bm m As o leading global mcnufacturer Over 30 in-house tests (UV,TC, HF,and many more) aro TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic • In-house testing goes well beyong certification requirements 3m products,we believe close O 2.w Nominal Operating Cell 45°C(±2°C) Operational Temperature -40-+85°C cooperation with our partners ro Temperature(NOCT) Maximum System t00oVDC(1EC)/ is Critical to success. With local 0.000 to.- 20m Spm 40m Temperature Coefficient of P_ -0.43%/°C Voltage 600V DC(UL) presence around the globe,Trino is Voltage(V) Temperature Coefficient of Vac -0.3 (.4axSeries Fuse Rot'r,�g 15A able to provide exceptionalservice Temperature CoefficientoFlsc 0.047 r y- r' to each customer in each market dT - `A and supplement our innovotive, Certified to withstand challenging environmental j Building Depar ant reliable products with the backing conditions t '',t of Trina as o strong,bankable 130 km/hr wind load (2400 Pa) WARRANTY }rte ryry partner. we ere committed 900 kg snow load per module (5400 Po) l0 year Product Workmanship warranty -' �' L��� to building strategic,mutually beneficiolcollaboration with 25 year Linear Power Warranty REVi E ! L; rt) in S101er5,developers,distributors (Please refer to product warranty for detailsl ��f�Pi.( gy and other partners as the �1 . backbone of our shored success in CERTIFICATION 't@Vt `Ned B,, -� R driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY �'�+ PACKAGING CONFIGURATION 10 Year Product Warranty • 25 Year Linear Power Warranty ^® .Caw'" Vus Modules per box:24 pieces Trina Solar Limited 1 11 A Modules per 40'container:672 pieces www.hinosolar.com `ml00% AZY tl 1 �►t' �E a UL us pYtreL[ unm .W dfHonal value yam Trina Solor's linear k'arronty . CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Trinasoaar O 80% : Trtnasolar change Solar Limited.All rights reserved.Specifications included in this dotasheet are subject to change without notice, fes/ Smart Energy TogetherSmart Energy Together W Years S 10 IS 20 25 ■ Industry standard ■ Tnnasolar I e� CS6P-235/240/245/250/255PX Netti�o,,ghF`a`� ,�!r CanadianSolar Electrical Data Black-framed sie STC CS6P-235P CS6P-240P CS6P-245P CSSP-250P CSSP-255PX Temperature Characteristics Nominal Maximum Power Pmax 235W 240W 245W 25OW 255W _ Optimum Operating Voltage Vm 29.8V 29.W 30.OV 30.1v 30.2V Pmax 1.0.43%NewEdgPC Optimum OperatingCurrent(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coemd.ril Voc -0.34%PC Open Circuit Voltage(Voc) 36.9V 37.W 37.1V 37.2V 37.4V I lac 10.065%PC Bl _ Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A NormalOperelingCeNTemperalure 45t2-C ' ' e Module Efficiency 14.61% 14.92% 15.23% 1 15.54% 15.85% -operating Temperature -40C­+65'C Performance at Low Irradiance ( Maximum System voltage 1000V 0C) /600V UL Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification ClassA irradlance of 1000wlm'to 200w1m' Power Tolerance 0-+5W (AM 1.5,25 1C) Next Generation Solar Module Under Standard Test Conditions(STC)ofirradianee of 1000W/m',spectrum AM 1.5 and all temperature of 25'C NewEdge,the next generation module designed for multiple Engineering Drawings NOCT S6P-235P CS6P-240P CS6P-245P CS6P•250PX CS6P•255PX types of mounting systems,offers customers the added Nominal Maximum Power Pmax 170W 174W 178W 181W 185W value of minimal system Costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2V 27.3V 27AV 27.5V 27.5V appearance,auto groundingand theft resistance. Optimum Operating Current(Imp) 417A 6.38A 6.49A 11.80A 6.71A Open Circuit Voltage(Voc) 33.9V 34.0v 34.1v 34.IV MAV The black-framed CS6P-PX is a robust 60 cell solar modlde Short Circuit Current(Isc) 6A.rA 6.%A 7.06A 7.19A 7.29A I incorporating the groundbreaking Zap compatible frame. Under Normal operating Call Temperature,Inn diana of 600 Wim',spectrurnAM I.S.ambient temperature 201C. The specially designed frame allows for rail-free fast wind speed 1 Wit installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 158 x 1 66mm,2 or 3 Busbars Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(8x 10) with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.57in) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(45.2 lbs) reduces installation time quality aesthetic module with lowest system cost. Front cover 3-2mmTempered glass • Lower system costs - can cut rooftop Frame Material Anodized aluminium alloy Installation costs In half Best Quality ,l-Box IP65,3 diodes • 235 quality control points in module production Cable 4mm'(IEC)/12AWG(UL),1000mm • Aesthetic seamless appearance - low profile Connectors MC4 or MC4 Comparable EL screening to eliminate product defects I Standard Packaging(Modules per Pallet) 24pcs mi with auto leveling and alignment • Current binning improve system performance Module Pieces per container(40 ft.Container) 672pcs(40'HO) o • Accredited Salt mist resistant • Built-in hyper-bonded grounding system - if it's I-V Curves (CS6P-255PX) mounted,it's grounded Best Warranty Insurance I • Theft resistant hardware • 25 years worldwide coverage • 100%warranty term coverage Section A-A j _ ______ • Ultra-low parts count - 3 parts for the mounting Providing third party bankruptcy rights y 350 and grounding system Non-cancellable • Industry first comprehensive warranty insurance by • Immediate coverage ,s: CUPERTINO AM Best rated leading insurance companies in the Insured by 3 world top insurance companies R t Y L3UIIC�1f1 0 world Comprehensive Certificates ' 2 �' partmenl • Industry leading plus only power tolerance:0­5W fl • IEC 61215,IEC 61730, IEC61701 ED2,UL1703, U °i t5 2014 • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS ground mounting systems • ISO9001:2008:Quality Management System " EVIEWEG11LD] GODE-Spectacations inctuded in this datesheet are subject to change whhout prior notice. lJ r•v fj, G e ISO/TS76949:2009:Theautomotivequality E COMPL;ArqCF • Backed By Our New 10125 Linear Power Warranty management system ReVieA ed 87 Plus our added 25 year insurance coverage • IS014001:2004:Standards for Environmental About Canadian Solar management system Canadlan Solar Inc.is one of the world's largest solar Canadian Solar was founded In Canada In 2001 and was '107 - QC080000 HSPM:The Certification for companies. As a leading vertically-Integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) in Added Value From W Hazardous Substances Regulations manufacturer of Ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing ao% Warranty solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. • OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide ao% occupational health and safety customers. Canadian Solar's world class team of e% REACH Com Mance professionals works closely with our customers to s 19 1s 20 3a P provide them with solutions for all their solar needs. Heada _ e .- •10 year product warranty on materials and workmanship O ; E G .. FvTel -1 519 83 7 1881 •25 year linear power output warranty Fax +1 51983725�O www.canadiansolar.com EN-R­10.17 Cppydsel 0 2012 dandle,soler Inc. Solar inverters Additional highlights: -•••• - RS-485 communication interface (for connection to laptop or data logger). - Integrated Arc Fault Detection and „a Interruption(-A Version). f' - Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US ' ASO Mechanical specifications .-.. ".. --..,.�_...e.. .-4 Nominal output power 3000W 3600W Wim: 380OW 420OW ...................................... ........................................_......._..................... ... ....... .. ... ...1 ...................i .........f f 1... ............... ..f....... ............... 4 .......:...4.. .......................t...42.................................................................. Maximum output power wattage 30b0 € 330b : 3$00 3600 Ob0 000 3300 : 00' : 4200 : 4200 : 4600 4600' p�y ....................................................................._..........,,.,....................""._W............_W.......i......w.............W......... W W W W W W W W Rated rid AC volts a 2osv 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V o a Input side(DO) _ Number of independent MPPT channels 2 2 2 2 LIM Maximum usable power for each channel 20DOW 3000W 3000W 3000W ..................................................................................................................................._........................................................................._..:........................................................... Absolute maximum voltage..(umm........._................................................. 600V Start-up voltage_(Vstart).....................................................i 200V(adj.:...120-350V)........................ ......... .................................................................................................... e FuII power MPPT voltage range...................................i..................160-530V.....................................120-530V 140-530V..................................140-530V .............. Operating MPPT voltage range0 7 x Vstart-580V(>--90V) M'azimum current(ldcrriazj for boffi MppT in a 20A 32A 32A 32A .parallel........................................ ..................:............................................. Maximum usable current per.channel 10A 16A ................��................... ..................16A........................ M' limit................1...............rr n Ilmit r ax short c rcu t cu e t pe 12.5A 20.OA 20.OA 20.OA channel _.................................................................................................................................................................:...........................................................:........................................_........................................................................... Number of wire landin terminals er channel ! 2 airs g........................P.. ....P......................................................_......._........................................ ..... �,,... .� Array wirin termination Terminal block,pressure clamp,AWG 10-AWG4 o Output side(AC) e Grid connection type 1 plrt- 10/ 1 spirt- 1 10/ SpT' 2W 0/3W 2W 2W 0/3W 2W 2W 0/3W 2W 2W 0/3W 2W ...........................................................................................................183...........2 .1............244............1$3.".......21.1..........244............1:33..........21.1...........244............183...........2 .1........244....... Adjustable voltage range(Vmin-Vmax)M 228V 264V 304V 228V 264V 304V 228V 264V 304V 228V 264V 304V ............................................................................................................._............................................................................................................................................................................................................................................ Grd frequency.........................................................................i................................._.... 60Hz Adjustable grid_frequency range57-60.51-1zMaximum current(1--) 14:5.. 14.5 ' 12.0 "iT:2 160 X8.0 : 10.0 'f60 ..16o 20.6 20.0 20:6 ...:..... s....:..... s.._:...........i.....Aw. ......._Awes....:...Aws....:....<4as......_..Aws.........�4as...J.... s....:.....�4ws..... Pos. war factor >0.995 Totalharmonic_distortion at rated..power................................................................................................................................'.. %°.................................................................................................................. This family of single-phase string The high-speed MPPT offers real- Highlights: Grid wiring termination type Terminal block.Pressure clamp,AW01 o-AWG4 inverters complements the typical time power tracking and improved - Single phase and split phase output Input protection devices , `: Reverse olari rotection Yes P..........?Y.P..................................................................."............................................................................_....................................................................._....................................................................................... number of rooftop solar panels energy harvesting. grid connection. Over-voltage protection type, Varistor,2 for each channel ..... ......... ............... enablinghome-owners to et the most The flat efficient curve ensures high - Wide input range for increased PV arra g y g p g y ground fault detection � Pre start-up Riso and Dynamid GFDI(requires floating arrays) efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. Output protection devices Anti-islanding protection Meets UL 1741AEEE1547 require is ff ''pc of the property. a consistent and stable performance - The high speed and precise MPPT F' f iJ PFR M, Over voltage protection type Varistor,2(L -L2/L G) ;z 1 Y �. ..... across the entire input voltage and algorithm offers real time power Maximum AC OCPD Rating20 20 15 25A_ 20A,_ 20 26A_ 2b zO � 25 2Rwifinn Department This inverter offers a dual input output power range. tracking and improved energy FJHcie section that processes two strings The transformerless operation gives the harvesting. __Maximum efficiency, -... 96.9% .97% 97 ._... ....., 97% ....._ -......_ ... q P 9 9 CECefficienc ,.. _..._..... 96%..... t .......................... r �06" with independent Multiple Power Point highest efficiency of up to 97.0%. - Outdoor NEMA 4X rated enclosure Oponiffinperformance' 1 Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <0.6W_, Stand-b consum tion <8W 5 This is especially useful for rooftop the inverter suitable to low power environmental conditions. - Communication installations with two different installations with reduced string size. - Integrated DC disconnect switch User-interlace 16 characters x 2 lines LCD dis lay t:U!�PL.eFgflf .............................................................................................................................................................................................................P.._......................_......................................................_ CE orientations from two sub-arrays This rugged outdoor inverter has been in compliance with international Remote monitoring(1XRS485 incl.) VSN700 Data Logger(opt.) 11a�ieyye o. Environmental oriented in different directions.(For designed to be a completely sealed Standards(S Version). ^ M yjyY` Ambient air operating.temperature._ ^.&8.............................................................................13°F to+140°F with deratin.8.above 122°F.�50� 1................................................................ example:East and West) unit able to withstand the harshest Ambient air storage temperature range 40 F to+176 F(40°C to+8o°C) ....... ......... .......... ........ ............... The dual input sections with environmental conditions. Relative humidify 0- RH condensing ............. independent MPPT enable a more Acoustic noise emission level <50 db(A)®1m ...................................................................................................................................................................................................................d ( ...............................................................................................................- Maximum o stip altitutde without deratin 6560 ft 2000 m optimal energy harvesting condition. Power and productivity 1.Capabiity enabled at nominal AC vdtage and with sufficient DC power available. for a better world" 2A22SodsrptvertmIProduct flyerfor%*-3.093.6/3:8/4.2-TI.-OUTD --, CUPERTINO Address SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 (408) 777 -3228 • FAX (408) 777 -3333 -; building(a.cupertino.org .U11 �� 4 //,,*q&nlf PURPOSE This affidavit is a self- certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314,2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single- family and multi- family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and /or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On ever level of a dwelling unit including basements X X Within each slee in room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel- burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above - referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. d d ree to com 1 with the terms and conditions of this statement 1 have rea an ag r- Owner (or Owner Agent's) Name: Sinature ................................................................................... ............................... Date: ................... Contractor ame: �— Date: l...Z. ... Si nature ........ ...... i .......... ..................... EQ Smoke and CO form.doc revised 03118114 y