14100006 CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 22352 BAHL ST CONTRACTOR: HUY THE BUI PERMIT NO: 14100006
OWNER'S NAME: CHUNG DAVID B AND MICHELLE M 48248 ARCADIAN ST DATE ISSUED: 10/22/2014
OWNER'S PHONE: 4076246016 FREMONT,CA 94539 PHONE NO:(408)206-0337
❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL ❑ COMMERCIAL E]
ADDITION 79 SQ FT TO REAR OF SFDWL, REMODEL
License Class1(,_ Lic.# 3WG?8 KITHCEN AND BATHROOOM 140 SQ FT
Contractor 1 U ll Date I
I hereby affirm that I am licensed under the provisions of Chapter 9
(commencing with Section 7000)of Division 3 of the Business&Professions
Code and that my license is in full force and effect.
1 hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$79
I have and will maintain Worker's Compensation Insurance,as provided for by
Section 3700 of the Labor Code,for the performance of the work for which this APN Number:32613097.00 Occupancy Type:
permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED
correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180,PAYS OF PERMIT ISSUANCE OR
to building construction,and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS F O LAST CALLED INSPF,+CTION.
indemnify and keep harmless the City of Cupertino against liabilities,judgments, bll-r/costs,and expenses which may accrue against said City in consequence of the /or
granting of this permit. Additionally,the applicant understands and will comply Issued by: Date:
with all non-point source regulations per the Cupertino Municipal Code,Section
9.18.
RE-ROOFS:
Signature Date � All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection,I agree to remove all new materials for
inspection.
❑ OWNER-BUILDER DECLARATION`
I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date:
the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A" OR BETTER
I,as owner of the property,or my employees with wages as their sole compensation,
will do the work,and the structure is not intended or offered for sale(Sec.7044,
Business&Professions Code)
I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE
construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the
California Health&Safety Code,Sections 25505,25533,and 25534. 1 will
I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the
declarations: Health&Safety Code,Section 25532(a)should 1 store or handle hazardous
I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous
Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District 1
performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and
I I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,25533,and 25534.
Section 3700 of the Labor Code,for the performance of the work for which this4
permit is issued. Owner or authorized agent: Date:_
EI certify that in the performance of the work for which this permit is issued,1 shall
! not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY
I become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of
forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.)
Lender's Name
APPLICANT CERTIFICATION Lender's Address
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction,and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes.(We)agree to save
indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION
costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records.
granting of this permit.Additionally,the applicant understands and will comply
with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional
9.18.
Signature Date
CONSTRUCTION PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE •CUPERTINO, CA 95014-3255
(408) 777-3228• FAX(408)777-3333• buildinq@cuipertino.org /4/ Q
CUPERTINO
❑NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION/Tl ❑ REVISION/DEFERRED ORIGINAL PERMIT#
PROJECT ADDRESS 13 0q_1 q t—7
- .
OWNERNAME ��117LJljt'ILLLI� PHO270g.(_O � (06 lY. E-MAIL (
STREET ADDRESS CITY, STATE,ZIP FAX
CONTACT�1@ CCi/I i Il l r�tC Y� PH�CI p•�S E 4 L �QOI L.UIrj .
I J 1Ef►YlJ�er C�
STREET ADDRESS CITY,STATE, ZIP FAX
❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAME LICENSE NUMBER 7 LICENSE TYPE BUS.LIC k
COMPANY NAME E-MAIL FAX
STREET ADDRESS CITY,STATE,ZIP PHONE
ARCHITECTIENGWEER NAME LICENSE NUMBER BUS.LIC k
COMPANY NAME E-MAIL FAX
STREET ADDRESS CITY,STATE,ZIP PHONE
DESCRIPTION OF WORK
Addi-6t)- < en t_wm "etkco
EMSTINGUSE PROPOSED USE CONSTR.TYPE k STORMS
USE TYPE OCC. SQ.FT. VALUATION(S)
EXISTG NEW FLOOR DEMO TOTAL
AREA AREA -^ AREA NET.AREA
BATHROOM KITCHEN OTHER
REMODEL AREA REMODEL AREA REMODEL AREA
PORCH AREA DECK AREA TOTAL DECKJPORCH AREA GARAGE AREA: DETACH
❑ATTACH
k DWELLING UNITS: IS A SECOND UNIT ❑YES SECOND STORY ❑YES
BEING ADDED? ❑NO ADDITION? ONO
f
PRE-APPLICATION [-]YES IF YES,PROVIDE COPY OF IS THE BLDG AN ❑YES RECEIVED BY: `TOTAL ATJ-Q;J.
PLANTING APPL O ❑NO PLANTING APPROVAL LETTER EICHLER HOME? ❑NO - - O D
By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
nstruction. I author e representatives of Cupertino to enter the above-i ent led property for inspection purposes.
ordinances and state laws relating to uildi a co
Signature of Applicant/Agent: Date:
SUPPLEMENTAL INFORMATION REQUIRED PLAN CHECK TYPE ROUTING SLIP
_New SFD or Multifamily dwellings: Apply for demolition permit for ❑ OVER-THE-COUNTER BUILDING PLAN REVIEW
existing building(s). Demolition permit is required prior to issuance of building
permit for new building. EXPRESS PLANNING PLAN REVIEW
_Commercial Bldgs: Provide a completed Hazardous Materials Disclosure . STANDARD PUBLIC WORKS
form if any Hazardous Materials are being used as part of this project.
❑ LARGE FIRE DEPT
_Copy of Planning Approval Letter or Meeting with Planning prior to 1/0
MAJOR. SANITARYSER'ERDISTRICTsubmirtal of Building Permit application.
ENVIRONMENTALHEALTH--
BldgApp_2011.doc revised 06/21/11
CITY OF CUPERTINO
FEE ESTIMATOR- BUILDING DIVISION
ADDRESS: 22352 bahl st DATE: 10/01/2014 REVIEWED BY: Mendez
APN: BP#: *VALUATION: 1$45,000
PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition
PRIMARY 2nd Unit? ; Yes No PENTAMATION
USE: SFD or Duplex OTC? 0 Yes No PERMIT TYPE: 1 R3SFDADD
WORK addition 79 sq ft to rear of sfdwl remodel kithcen and bathr000m 140 sq ft
SCOPE
OCCUPANCY TYPE: TYPE OF FLR AREA PC FEES PC FEE ID BP FEES BP FEE ID
CONSTR. s.f.
R-3 (Custom) II-B,III-B,IV,V-B 79 $1,091.00 IADDPLCK $1,057.00 IADDINSP
TOTALS: 79 $1,091.00 $1,057.00
MECH, HOURLY 0 Yes 0 No PLUMB,HOURLY Q Yes Q No ELEC,HOURLY Q Yes 0 No
NOTE: This estimate does not include fees due to other Departments(i.e.Planning, Public Works, Fire,Sanitary Sewer District,School
District,etc. . Thesefees are based on the prelinzinar information available and are only an estimate Contact the De t or addn'1 info.
FEE ITEMS (Fee Resolulion 11-053 Cf( 7T 3) FEE QTY/FEE MISC ITEMS
Plan Check Fee: $1,091.00 F140S.f. Remodel,Other
Suppl. PC Fee: Q Reg. 0 OT FO.0 I hrs $0.00 $431.00 IREMRESOTH
PME Plan Check: $0.00
Permit Fee: $1,057.00
Suppl. Insp. Fee:Q Reg. Q OT 1 0,0 1 hrs $0.00
PME Unit Fee: $0.00
PME Permit Fee: $0.00
FTC'uit,tructi��n lir:E:
1,hnh7l.str,i,tivc C-.
Work Without Permit? (D Yes (j) No $0.00
Advanced Planning Fee: 1PLLONGR $11.06 Select a Non-Residential
7rtnvl Fcc,s Building or Structure 0
i
Strong Motion Fee: /BSEISw1ICR $5.85 Select an Administrative Item
B_I_dtg Stds Commission Fee: 1BCBSC $2.00
SUBTOTALS: $2,166.91 $431.00 TOTAL FEE: $2,597.91
Revised: 08/20/2014
Building Department
City Of Cupertino
10300 Torre Avenue
Cupertino,CA 95014-3255
Telephone: 408-777-3228
CUPERTINO Fax: 408-777-3333
CONTRACTOR/ SUBCO CTOR LIST
JOB ADDRESS: "' " PERMIT# 0000(6
OWNER'S NAME: 1,21VAa Q(( C41VAI PHONE# q0Y - 6,q-0 -- 7,53-5
GENERAL CONTRACTOR: BUSINESS LICENSE#
ADDRESS: ly Ye CITY/ZIPCODE: , 5
*Our municipal code requires all businesses working in the city to have a City of Cupertino business license.
NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE
GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO
BUSINESS LICENSE. 2
2 / 7 �f
I am not using any subcontractors: �/ -G `
Signature Date
Please check applicable subcontractors and complete the following information:
V SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE #
Cabinets & Millwork
L- Cement Finishing
L,- Electrical
Excavation
Fencing
Flooring/Carpeting
Linoleum/ Wood
Glass/Glazing
Heating
V Insulation �._--
Landscaping
Lathing
Masonry
aim V Wallpaper ;
Paving
Plastering
y- Plumbing
Roofing
Septic Tank
Sheet Metal
f, Sheet Rock -
L Tile j<
Owne /Contractor Signature Date
CALGREEN RESIDENTIAL CHECKLIST - MANDATORY
ITEMS
COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION
CUP�SitTllV+D ALBERT SALVADOR, P.E.,C.B.O., BUILDING OFFICIAL
10300 TORRE AVENUE•CUPERTINO, CA 95014-3255
(408)777-3228• FAX(408)777-3333• building(a,cupertino.org
PURPOSE:
The 2013 CalGreen Code applies to all newly constructed hotels, motels, lodging houses, dwellings,
dormitories, condominiums, shelters, congregate residences, employee housing, factory-built housing and
other types of swellings with sleeping accommodations and new accessory buildings associated with such
uses. Existing site and landscaping improvements that are not otherwise disturbed are not subject to the
requirements of CALGreen.
Project Name: �,-
Project Address: ,`?� 2j � - � �} L �Z �rJ��� �j C4 9 L�
Project Description: 1-cc? 04�N_,
Instructions:
1. The Owner or the Owner's agent shall employ a licensed pr f io I e nce with the California
Green Building Standards Codes to verify anWter�
it o described herein is properly
planned and implemented in the project.
2. The licensed professional, in collaboration wi the design professional shall initial Column
2 of this checklist, sign and date Section 1 - cation at the end of this checklist and have the
checklist printed on the approved plans for the project.
3. Prior to final inspection by the Building Department, the licensed professional shall complete Column 3
and sign and date Section 2 - Implementation Verification at the end of this checklist and submit the
completed form to the Building Inspector.
Column 2 Column 3
MANDATORY FEATURE OR MEASURE Project Verification
Requirements
A4.1 PLANNING AND DESIGN
Planning and Design - Site Development
4.106.2 Storm water drainage and retention during construction. A plan is
developed and implemented to manage storm water drainage during ❑X ❑
construction.
4.106.3 Grading and paving. The site shall be planned and developed to
keep surface water away from buildings. Construction plans shall indicate how ® ❑
site grading or a drainage system will manage all surface water flows.
Page I of 5 CalGreen_2014.doc revised 01/15/14
A4.2
General
4.201.1 Low-rise residential buildings shall meet or exceed the minimum
standard design required by the California Energy Standards.
A4.3 WATER EFFICIENCY AND CONSERVATION
Indoor Water Use
4.303.1 Water conserving plumbing fixtures and fittings. Plumbing fixtures
(water closets and urinals)and fittings(faucets and showerheads)shall comply
with the following:
❑ 4.303.1.3.2 Water Closets.The effective flush volume of all water closets
shall not exceed 1.28 gallons per flush. Tank-type water closets shall be
certified to the performance criteria of the U.S. EPA WaterSense
Specifications for Tank-type Toilets.
❑ 4.303.1.3.2 Urinals. The effective flush volume of urinals shall not
exceed 0.5 gallons per flush.
❑ 4.303.1.3.1 Single Showerheads. Showerheads shall have a maximum
flow rate of not more than 2.0 gallons per minute at 80 psi. Showerheads
shall be certified to the performance criteria of the U.S. EPA WaterSense
Specification for showerheads.
❑ 4.303.1.3.2 Multiple Showerheads serving one shower. When a
shower is served by more than one showerhead, the combined flow rate of
all showerheads and/or other shower outlets controlled by a single valve
shall not exceed 2.0 gallons per minute at 80 psi, or the shower shall be ❑X
designed to allow only one shower outlet to be in operation at a time.
❑ 4.303.1.4.1 Residential lavatory faucets. The maximum flow rate of
residential lavatory faucets shall not exceed 1.5 gallons per minute at 60
psi. The minimum flow rate of residential lavatory faucets shall not be less
than 0.8 gallons per minute at 20 psi.
❑ 4.303.1.3.2 Lavatory faucets in common and public use areas. The
maximum flow rate of lavatory faucets installed in common and public use
areas(outside of dwellings or sleeping units) in residential buildings shall
not exceed 0.5 gallons per minute at 60 psi.
❑ 4.303.1.4.3 Metering faucets. Metering faucets when installed in
residential buildings shall not deliver more than 0.25 gallons per cycle.
❑ 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets
shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may
temporarily increase the flow above the maximum rate, but not to exceed
2.2 gallons per minute at 60 psi, and must default to a maximum flow rate
of 1.8 gallons per minute at 60 psi.
4.303.2 Standards for plumbing fixtures and fittings. Plumbing fixtures
and fittings shall be installed in accordance with the California Plumbing Code,
and shall meet the applicable standards referenced in Table 1401.1 of the
California Plumbing Code.
Page 2 of 5 CalGreen_20/4.doc revised 01//5//4
Outdoor Water Use
4.304.1 Irrigation controllers. Automatic irrigation systems installed at the
time of final inspection shall be weather-based.
❑ 4.304.1.1 Controllers shall be weather-or soil moisture-based controllers
that automatically adjust irrigation in response to changes in plants' needs
as weather conditions change. ❑ ❑
❑ 4.304.1.2 Weather-based controllers without integral rain sensors or
communication systems that account for local rainfall shall have a separate
wired or wireless rain sensor which connects or communicated with the
controller(s). Soil moisture-based controllers are not required to have rain
sensor input.
A4.4
Enhanced Durability and Reduced Maintenance
4.406.1 Rodent proofing. Annular spaces around pipes, electric cables,
conduits, or other openings in plates at exterior walls shall be protected ❑ ❑
against the passage of rodents by closing such openings with cement mortar,
concrete masonry or similar method acceptable to the enforcing agency.
Construction Waste Reduction, Disposal and Recycling
4.408.2 Construction waste management plan. Where a local jurisdiction
does not have a construction and demolition waste management ordinance, a ❑ ❑
construction waste management plan shall be submitted for approval to the
enforcing agency.
Building Maintenance and Operation
4.410.1 Operation and maintenance manual. At the time of final inspection,
an operation and maintenance manual shall be provided to the building ❑X ❑
occupant or owner.
A4.5 ENVIRONMENTAL QUALITY
Fireplaces
4.503.1 General. Install only a direct-vent sealed-combustion gas or sealed ❑ ❑
wood-burning fireplace, or a sealed woodstove.
Pollutant Control
4.504.1 Covering of duct openings and protection of mechanical
equipment during construction. Duct openings and other related air ❑X ❑
distribution component openings shall be covered during construction.
4.504.2.1 Adhesives, sealants and caulks. Adhesives, sealants and caulks ❑ ❑
shall be compliant with VOC and other toxic compound limits.
4.504.2.2 Paints and coatings. Paints, stains and other coatings shall be ❑ ❑
compliant with VOC limits.
4.504.2.3 Aerosol paints and coatings. Aerosol paints and other coatings
shall be compliant with product weighted MIR Limits for ROC and other toxic ❑X ❑
compounds.
Page 3 of 5 Ca(Creen_2014.doc revised 01/15/14
4.504.2.4 Verification. Documentation shall be provided to verify that
compliant VOC limit finish materials have been used.
4.504.3 Carpet Systems. Carpet and carpet systems shall be compliant with
VOC limits. L.Nj El
4.504.4 Resilient flooring systems. Eighty(80) percent of floor area
receiving resilient flooring shall comply with the VOC-emission limits defined in
the Collaborative for High Performance Schools (CHIPS) Low-emitting ❑X ❑
Materials List or be certified under the Resilient Floor Covering Institute(RCFI)
FloorScore program.
4.504.5 Composite wood products. Particleboard, medium density
fiberboard (MDF), and hardwood plywood used in interior finish systems shall ❑X
comply with low formaldehyde emission standards.
Interior Moisture Control
4.505.2 Concrete slab foundation. Required vapor retarders and capillary
breaks are also required to comply with CalGreen Section 4.505.2.1.
4.505.3 Moisture content of building materials. Moisture content of building
materials used in wall and floor framing is checked before enclosure.
Indoor Air Quality and Exhaust
4.506.1 Bathroom exhaust fans. Exhaust fans which terminate outside the
building are provided in every bathroom.
Environmental Comfort
4.507.2. Duct systems are sized and designed and equipment is selected
using the following methods:
1. Establish heat loss and heat gain values according to ACCA Manual J or
equivalent.
2. Size duct systems according to ACCA 29-D (Manual D)or equivalent.
3. Select heating and cooling equipment according to ACCA 36-S (Manual S)
or equivalent.
INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS
Qualifications
702.1 Installer training. HVAC system installers are trained and certified in
the proper installation of HVAC systems.
702.2 Special inspection. The Licensed Professional responsible to verify
CALGreen compliance is qualified and able to demonstrate competence in the ❑X ❑
discipline they inspect and verify.
Verifications
703.1 Documentation. Verification of compliance with CALGreen may
include construction documents, plans, specifications, builder or installer
certification, inspection reports, or other methods acceptable to the enforcing
agency which show substantial conformance. Implementation verification shall
be submitted to the Building Department after implementation of all required
measures and prior to final inspection approval.
Page 4 of 5 CalCreen_2014.doe revised 01/15114
CALGREEN SIGNATURE DECLARATIONS
Project Name:
Project Address:
Project Description:
SECTION 1 - DESIGN VERIFICATION
Complete all lines of Section 1 —"Design Verification"and submit the completed checklist(Columns 1 and 2)with the
plans and building permit application to the Building Department.
The owner and design professional responsible for compliance with CalGreen Standards have revised the plans and
certify that the items checked above are hereby incorporated into the project plans and will be implemented into the
project in accordance with the requirements set forth in the 2013 California Green Building Standards Code as
adopted by the City of Cupertino.
s1xgf0 z2—,2 4 T
Owner's Signature, Date
r
r 6 (3 • cf-hU u
Owner's Name (Please Print)
Design Professional's Signature Date
` to-z� •r�
Design Professio al's Name (Please Print)
Sign ture of License Professional responsible for CalGreen compliance Date
uv S , ySJ- g2
ame of License Professional responsible for CalGreen compliance(Please Print) Phone
. � 1
Email Address for License Professional Uponsible for CalGreen compliance
SECTION 2 - IMPLEMENTATION VERIFICATION
Complete, sign and submit the competed checklist, including column 3, together with all original signatures on Section
2 to the Building Department prior to Building Department final inspection.
I have inspected the work and have received sufficient documentation to verify and certify that the project identified
above was constructed in accordance with this Green Building Checklist and in accordance with the requirements of
the 2013 California Green Building Standards Code as adopted by the City of Cupertino.
Signature of License Professional responsible for CalGreen compliance Date
Name of License Professional responsible for CalGreen compliance(Please Print) Phone
Email Address for License Professional responsible for CalGreen compliance
Page 5 of 5 CatGreen_2014.doc revised 01/15/14
BUILDING ENERGY ANALYSIS REPORT
PROJECT: 0
Chung Addition
22352 Bahl Street
Cupertino, CA 95014
Project Designer:
Plans And Design
6490 Kings Place 0
Gilroy, CA 95020 O
408-505-3751 0
Report Prepared by:
Timothy Carstairs, CEA, HERS, GPR
Carstairs Energy Calculations
PO Box 4736
San Luis Obispo, CA 93403
(805) 904-9048
Job Number:
14-091713
Date:
9/17/2014
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report.This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft,LLC—www.energysoft.com.
Ener Pro 6.3 by Ener Soft User Number:6249 9D:14-091713
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF-1 R Certificate of Compliance 3
Form RMS-1 Residential Measures Summary 11
Form MF-1 R Mandatory Measures Summary 12
EnergyPro 6.3 by EnergySoft Job Number: ID:14-091713 User Number:6249
CERTIFICATE OF COMPLIANCE-RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residential Building Calculation Date/Time: 16:07,Wed,Sep 17,2014 Page 1 of 8
Calculation Description:Title 24 Analysis Input File Name:Chung Addition(2014).xml
GENERAL INFORMATION
01 Project Name Residential Building
02 Calculation Description Title 24 Analysis
03 Project Location 22352 Bahl Street
04 CA City Cupertino 05 Standards Version Compliance 2014
06 Zip code 95014 07 Compliance Manager Version BEMCmpMgr 2013-3(650)
08 Climate Zone CZ4 09 Software Version EnergyPro 6.3
10 Building Type Single Family 11 Front Orientation(deg/Cardinal) 315
12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1
14 Total Cond. Floor Area(FT2) 2526 15 Number of Zones 2
16 Slab Area(FT2) 0 17 Number of Stories 1
18 Addition Cond.Floor Area 79 19 Natural Gas Available Yes
20 Addition Slab Area(FT2) 0 21 Glazing Percentage(%) 11.3%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
ENERGY USE SUMMARY
04 05 06 07 08
Energy Use(kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 51.88 50.68 1.20 2.3%
Space Cooling 28.72 28.70 0.02 0.1%
IAQ Ventilation 0.00 0.00 0.00 0.0%
Water Heating 12.61 12.61 0.00 0.0%
Photovoltaic Offset ---- 0.00 0.00 ---
TOTAL 93.21 91.99 1.22 1.3%
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version-CF1R-09042014-650 Report Generated at 2014-09-17 16:09:50
CERTIFICATE OF COMPLIANCE-RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residential Building Calculation Date/Time: 16:07,Wed,Sep 17,2014 Page 2 of 8
Calculation Description:Title 24 Analysis Input File Name:Chung Addition(2014).xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cathedral Ceiling
PROJECT HERS FEATURES
The following are project-level features that must be field-verified as a condition for meeting the modeled energy performance for this computer analysis. These,plus any additional HERS features listed
in the building components tables below requre field verification by a certified HERS Rater.
Check the individual building component sections below for any required HERS verification requirements.
BUILDING FEATURE INFORMATION
01 02 03 04 05 06 07
Number of Dwelling Number of Number of Water
Project Name Conditioned Floor Area(sft) Units Number of Bedrooms Number of Zones Ventilation Cooling Systems Heating Systems
Residential Building 2526 1 4 2 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Floor Area Avg.Ceiling
Zone Name Zone Type HVAC System Name (ft2) Height Water Heating System 1 Water Heating System 2
1st Floor Existing Conditioned HVAC System1 2447 8 DHW Sys 1
1st Floor Addition Conditioned HVAC System1 79 8 DHW Sys 1
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version-CF1R-09042014-650 Report Generated at 2014-09-17 16:09:50
CERTIFICATE OF COMPLIANCE-RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Project Name:Residential Building Calculation Date/Time: 16:07,Wed,Sep 17,2014 Page 3 of 8
Calculation Description:Title 24 Analysis Input File Name:Chung Addition(2014).xml
OPAQUE SURFACES
01 02 03 04 05 06 07 08 09 10
Window Verified
or Door Area(ft2 Existing
Name Zone Construction Azimuth Orientation Gross Area(ft2) ) Tilt(deg) Status Condition
Front Wall 1st Floor Existing R-0 Wall 315 Front 290 60 90 Existing No
Left Wall 1st Floor Existing R-0 Wall 45 Left 392 65.4 90 Existing No
Rear Wall 1st Floor Existing R-0 Wall 135 Back 352 53.4 90 Existing No
Right Wall 1st Floor Existing R-0 Wall 225 Right 478 81 90 Existing No
Interior Surface 1st Floor Existing»Garage R-0 Walll 254 Existing No
Roof 2 1 st Floor Existing R-11 Roof Attic 2439 Existing No
Raised Floor 1st Floor Existing R-0 Floor Crawlspace 2447 Existing No
Rear Wall 2 1st Floor Addition R-13 Wall 135 Back 49 17.5 90 New N/A
Rear Wall 3 1st Floor Addition R-13 Wall 135 Back 49 90 New N/A
Roof 3 1 st Floor Addition R-30 Roof Attic 39.5 New N/A
Roof 4 1st Floor Addition R-30 Roof Attic 39.5 New N/A
Raised Floor 2 1st Floor Addition R-19 Floor Crawlspace 39.5 New N/A
Raised Floor 3 1st Floor Addition R-19 Floor Crawlspace 39.5 New N/A
Front Wall 2 Garage Garage Ext Wall 315 Front 160 90 Existing No
Left Wall 2 Garage Garage Ext Wall 45 Left 172 90 Existing No
Rear Wall 4 Garage Garage Ext Wall 135 Back 160 90 Existing No
Right Wall 2 Garage Garage Ext Wall 225 Right 172 90 Existing No
Roof 5 Garage R-11 Roof Attic 425 Existing No
OPAQUE SURFACES—Cathedral Ceilings
01 02 03 04 05 06 07 08 09 10 11 12 13
Roof Roof Roof Framin Verified
Rise(x Roof Roof Reflectanc Emmittanc g Existing
Name Zone Type Orientation Area(ft2) in 12) Pitch Tilt(deg) e e Factor Status Condifion
Roof 1st Floor Existing R-11 Roof Attic -specify- 8.1 0 0 0 0.1 0.85 0.07 Existing No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version-CF1R-09042014-650 Report Generated at 2014-09-17 16:09:50
CERTIFICATE OF COMPLIANCE-RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residential Building Calculation Date/Time: 16:07,Wed,Sep 17,2014 Page 4 of 8
Calculation Description:Title 24 Analysis Input File Name:Chung Addition(2014).xml
ATTIC
01 02 03 04 05 WNo
09 10 11
Verified
Roof Roof Existing
Name Construction Roof Rise Reflectance Emittanceol Roof Status Condifion
Attic Attic Roof Cons 0 0.1 0.85No Existing No
WINDOWS
01 02 03 04 05 06 07 08 09 10 11
Verified
Width(ft Height Multiplie Existing
Name Side of Building ) (ft) r Area(ft) U-factor SHGC Exterior Shading Status Condition
Window Front Wall ---- --- 1 30.0 1.98 0.83 Existing No
Window 2 Front Wall --- ---- 1 30.0 1.98 0.83 Existing No
Window 3 Left Wall ---- ---- 1 6.0 0.32 0.25 New N/A
Window 4 Left Wall --- 1 6.0 1.98 0.83 Existing No
Sliding Glass Door Left Wall ---- ---- 1 53.4 1.25 0.83 Existing No
Sliding Glass Door 2 Rear Wall --- ---- 1 53.4 0.32 0.25 New N/A
Window 5 Right Wall ---- ---- 1 15.0 1.98 0.83 Existing No
Window 6 Right Wall ---- ---- 1 15.0 1.98 0.83 Existing No
Window 7 Right Wall ---- ---- 1 15.0 1.98 0.83 Existing No
Window 8 Right Wall ---- ---- 1 18.0 1.98 0.83 Existing No
Window 9 Right Wall ---- ---- 1 18.0 1.98 0.83 Existing No
Skylight Roof 1 8.0 1.98 0.83 Existing No
Window 10 Rear Wall 2 --- ---- 1 17.5 0.32 0.25 New N/A
DOORS
01 02 03 04 05 06
Name Side of Building Area(ft2) U-factor Status Verified Existing Condition
Door Front Wall 40.0 0.50 Existing No
Door 2 Interior Surface 18.0 0.50 Existing No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version-CF1R-09042014-650 Report Generated at 2014-09-17 16:09:50
CERTIFICATE OF COMPLIANCE-RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residential Building Calculation Date/Time: 16:07,Wed,Sep 17,2014 Page 5 of 8
Calculation Description:Title 24 Analysis Input File Name:Chung Addition(2014).xml
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05
Construction Name Surface Type Framing Total Cavity R-value Assembly Layers
Roofing:Light Roof(Asphalt Shingle)
2x4 Top Chord of Roof Above Deck Insulation-no insulation-
Attic Roof Cons Attic Roofs Truss @ 24 in.O.C. -no insulation- Roof Deck:Wood Siding/sheathing/decking
Cavity:-no insulation-
Inside Finish:-select inside finish-
inside Finish:Gypsum Board
Sheathing/Insulation:-no sheathingfinsul.-
R-0 Wall Exterior Walls 2x4 @ 16 in.O.C. -no insulation(vertical)- Cavity:-no insulation(vertical)-
Sheathing/Insulation:-no sheathingfinsul.-
Exterior Finish:Wood Siding/sheathing/decking
Attic Floor:-no attic floor-
R-11 Roof Attic Ceilings(below attic) 2x4 @ 24 in.O.C. R 11 Cavity:R 11
Sheathinglnsulation-no sheathinglinsul.-
Inside Finish:Gypsum Board
Floor Surface:Carpeted
Concrete Fill:-no concrete fill-
R-0 Floor Crawlspace Floors Over Crawlspace 2x12 @ 16 in.O.C. no insulation- Floor Deck:Wood Siding/sheathing/decking
Cavity:-no insulation-
Sheathing/Insulation:-no sheathingfinsul.-
Exterior Finish:-select finish-
Roofing:Light Roof(Asphalt Shingle)
Above Deck Insulation-no insulation-
R-11 Roof Attic Cathedral Ceilings 2x4 @ 24 in.O.C. R 11 Roof Deck:Wood Siding/sheathing/decking
Cavity:R 11
inside Finish:Gypsum Board
Inside Finish:Gypsum Board
Sheathing/Insulation:-no sheathingfinsul.-
R-0 Walll Interior Walls 2x4 @ 16 in.O.C. no insulation(vertical)- Cavity:-no insulation(vertical)-
Sheathing/Insulation:-no sheathingfinsul.-
Other Side Flnish:Gypsum Board
Floor Surface:Carpeted
Concrete Fill:-no concrete fill-
R-19 Floor Crawlspace Floors Over Crawlspace 2x6 @ 16 in.O.C. R 19 Floor Deck:Wood Siding/sheathing/decking
Cavity:R 19
Sheathing/Insulation:-no sheathingfinsul.-
Exterior Finish:-select finish-
Inside Finish:Gypsum Board
Sheathing/Insulation:-no sheathingfinsul.-
R-13 Wall Exterior Walls 2x4 @ 16 in.O.C. R 13 Cavity:R 13
Sheathing/Insulation:-no sheathing/insul.-
Exterior Finish:Wood Siding/sheathing/decking
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version-CF1R-09042014-650 Report Generated at 2014-09-17 16:09:50
CERTIFICATE OF COMPLIANCE-RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Residential Building Calculation Date/Time: 16:07,Wed,Sep 17,2014 Page 6 of 8
Calculation Description:Title 24 Analysis Input File Name:Chung Addition(2014).xml
Attic Floor:-no attic floor-
R-30 Roof Attic Ceilings(below attic) 2x4 @ 24 in.O.C. R 30 Cavity:R 30
Sheathinglnsulation-no sheathing/insul. -
Inside Finish:Gypsum Board
WATER HEATING SYSTEMS
01 02 03 04 05 06
Verified Existing
Name Distribution Type Number of Heaters Solar Fraction(%) Ststus Condition
DHW Sys 1 Standard 1 Annual Existing No
WATER HEATERS
01 02 03 04 05 06 07 08
Tank Volume Energy Factor or Tank Exterior Standby Loss
Name Heater Element Type Tank Type (gal) Efficiency Input Rating Insulation R-value (Fraction)
DHW Heater 1 Natural Gas Small Storage 50 0.575 EF 40000-Btu/hr 0 0
WATER HEATING-HERS VERIFICATION
01 02 03 04 05 06 07
Recirculation with Recirculation with
Name Pipe Insulation Parallel Piping Compact Distribution Point-of Use Manual Control Sensor Control
DHW Sys 1 n/a n/a n/a n/a n/a n/a
HVAC SYSTEMS
01 02 03 04 05 06 07 08 09
Heating System Cooling System
Distribution Fan Floor Area Verified Existing
Name System Type Name Ducted Name Ducted System System Served Status Condition
Other Heating and Heating Cooling Air Distribution HVAC Fan
HVAC Systeml Cooling System Component 1 Yes Component 1 Yes System 1 1 2526 Existing No
HVAC-HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace-Fuel-fired central furnace 78 AFUE
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version-CF1R-09042014-650 Report Generated at 2014-09-17 16:09:50
CERTIFICATE OF COMPLIANCE-RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residential Building Calculation Date/Time: 16:07,Wed,Sep 17,2014 Page 7 of 8
Calculation Description:Title 24 Analysis Input File Name:Chung Addition(2014).xml
HVAC-COOLING SYSTEMS
01 02 03 04 05 06 07
Efficiency
Multi-speed
Name System Type EER SEER Zonally Controlled Compressor HERS Verification
Cooling Component 1 SplitAirCond-Split air conditioning 11.3 13 No No Cooling Component
system 1-hers-cool
HVAC- DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 08
Insulation Supply Duct Return Duct Verify Existing HERS
Name Type Duct Leakage R-value Location Location Bypass Duct Status Condition Verification
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version-CF1R-09042014-650 Report Generated at 2014-09-17 16:09:50
CERTIFICATE OF COMPLIANCE-RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residential Building Calculation Date/Time: 16:07,Wed,Sep 17,2014 Page 8 of 8
Calculation Description:Title 24 Analysis Input File Name:Chung Addition(2014).xml
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1.1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Documentation Author Signatur.!
Timothy Carstairs, CEA, HERS, GPR l
Company: Signature Date:
Carstairs Energy Calculations 9/17/2014 L B C
Califanut yp,u[ron°(Budpin Ener yC°nwlraim
Address: CEA/HERS Certification Identification(If applicable):
PO Box 4736
City/State ip: Phone:
San Luis Obispo, CA 93403 (805) 904-9048
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury,under the laws of the State of California.
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24,Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets,calculations,plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name. ResponsibleDesigner Signature:
Dean Kimbler
Company: Date Signed:
Plans And Design
Address: License:
6490 Kings Place
City/State/Zip: Phone:
Gilroy, CA 95020 408-505-3751
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version-CF1R-09042014-650 Report Generated at 2014-09-17 16:09:50
RESIDENTIAL MEASURES SUMMARY RMS-1
Project Name Building Type 0 Single Family ❑Addition Alone Date
Chung Addition ❑ Multi Family 2 Existing+Addition/Alteration 9/17/2014
Project Address California Energy Climate Zone Total Cond. Floor Area Addition #of Units
22352 Bahl Street Cupertino CA Climate Zone 04 2,526 79 3
INSULATION Area
Construction Type Cavity (ft) Special Features Status
Floor Wood Framed w/Crawl Space no insulation 2,447 Existing
Wall Wood Framed no insulation 1,448 Existing
Door Opaque Door no insulation 40 Existing
Roo( Wood Framed Attic R 11 2,439 Existing
Demising Wood Framed -no insulation 98 New
2
Floor Wood Framed w/Crawl Space R 19 79 New
Wall Wood Framed R 13 81 New
Roo( Wood Framed Attic R 30 79 New
FENESTRATION Total Area: 285 Glazing Percentage: 11.3% New/Altered Average U-Factor: 0.32
Orientation Area(ft) U-Fac SHGC Overhang Sidefins Exterior Shades Status
Front(NM 60.0 1.980 0.83 none none Bug Screen Existing
i Left(NE) 6.0 0.320 0.25 none none Bug Screen New
s
Left(NE) 6.0 1.980 0.83 none none Bug Screen Existing
Left(NE) 53.4 1.250 0.83 none none Bug Screen Existing
t
Rear(SE) 53.4 0.320 0.25 none none Bug Screen New
Right(SW) 81.0 1.980 0.83 none none Bug Screen Existing
Skylight 8.0 1.980 0.83 none none None Existing
Rear(SE) 17.5 0.320 0.25 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 78%AFUE Split Air Conditioner 13.0 SEER Setback Existing
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
HVAC System Ducted Ducted Attic 4.2 Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnergyPro 6.3 by Ener Soft User Number:6249 RunCode:2014-09-17T16:10:07 ID: 14-091713 Pae 11 0(14
MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1R
Project Name Date
Chung Addition 9/17/2014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance(CF-1 R,CF-1 R-ADD,or CF-
1 R-ALT Form)shall supersede the items marked with an asterisk(*)below.This Mandatory Measures Summary shall be incorporated
into the permit documents,and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary.Submit all applicable sections of the MF-1 R
Form with plans.
Building Envelope Measures:
110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§110.6(a)4: Fenestration products(except field-fabricated windows)have a label listing the certified U-Factor,certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111(a).
110.7: Exterior doors and windows are weather-stripped;all joints and penetrations are caulked and sealed.
110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-2R Form.
§110.8(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of§110.8(i)when the
installation of a Cool Roof is specified on the CF-1 R Form.
*§1 50.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood-frame ceiling or equivalent U-factor.
§150.0(b): Loose fill insulation shall conform w'th manufacturer's installed design labeled R-Value.
*§1 50.0 c : Minimum R-13 insulation in 2x4 wood-frame wall R-19 in 2x6 orequivalent U-factor.
*§150.0(# Minimum R-19 insulation in raised wood-frame floor orequivalent U-factor.
150.0(f):Air retarding wrap is tested, labeled,and installed according to ASTM El677-95 2000 when specified on the CF-1 R Form.
§150.0(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150.0(1):Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%;water vapor permeance
rate is no greater than 2.0 permlinch and shall be protected from physical damage and UV light deterioration.
§150.0(q)Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the
requirements of either Item 1 or 2 below:
1. Fenestration, including skylight products, must have a maximum U-factor of 0.58.
2.The weighted average U-factor of all fenestration, including skylight products,shall not exceed 0.58.
EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area,whichever is
reater, is exempt from the maximum U-factor requirement.
150.0 r Solar Ready Buildings.Shall meet the requirements of Section 110.10 applicable to the building project.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150.0 e 1A: Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)l B: Masonry or factory-built fireplaces have a combustion outside air intake,which is at least six square inches in area and is
equipped with a with a readily accessible,operable,and tight-fitting damper and or a combustion-air control device.
§150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket,when that indoor air is vented to the
outside of the building,are prohibited.
Space Conditioning,Water Heating and Plumbing System Measures:
§110.0-§110.3: HVAC equipment,water heaters, showerheads,faucets and all other regulated appliances are certified by the Energy
Commission.
§110.3(c)5:Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve,and recirculation loop connection requirements of§110.3(c)5.
§110.5: Continuously burning pilot lights are prohibited for natural gas:fan-type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
§150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
§150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2 c .
§150.00)1A:Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally
wrapped with insulation having an installed thermal resistance of R-12 or greater.
§150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water-heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the
tank.
EnergyPro 6.3 by EnergySoR User Number:6249 ID:14-091713 Page 12 of 14
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R
Project Name Date
Chung Addition 9/17/2014
§150.00)2A: All domestic hot water system piping conditions listed below,whether buried or unburied, must be insulated per TABLE
120.3-A.
i. The first 5 feel(1.5 meters)of hot and cold water pipes from the storage tank.
ii.All piping with a nominal diameter of 3/4 inch (19 millimeter)or larger.
iii.All piping associated with a domestic hot water recirculation system regardless of the pipe diameter.
iv. Piping from the heating source to storage tank or between tanks.
v. Piping buried below grade.
vi.All hot water pipes from the heating source to the kitchen fixtures.
§150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems>15 psi, meets the requirements of Standards
Table 120.3-A.
§150.0(j)3A: Insulation is protected from damage, including that due to sunlight,moisture,equipment maintenance,and wind.
§150.00)4: Solar water-heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
§150.0(m)l:All air-distribution system ducts and plenums installed,are sealed and insulated to meet the requirements of CMC
Sections 601,602, 603,604, 605 and Standard 6-5;supply-air and return-air ducts and plenums are insulated to a minimum installed
level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic,tape or other duct-closure system that
meets the applicable requirements of LIL 181, UL 181A,or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic
or tape is used to seal openings reater than 1/4 inch,the combination of mastic and either mesh or tape shall be used
§150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal,duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150.0(m)2D:Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150.0(m)7: Exhaust fans stems have back draft or automatic dampers.
§150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150.0(m)9: Insulation shall be protected from damage,including that due to sunlight, moisture,equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
)
150.0(m)10: Flexible ducts cannot have porous inner cores.
§150.0(n)l: Systems using gas or propane water heaters,whether tank or on-demand,to serve individual dwelling units shall include
all the following components :
A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions;
B. A Category III or IV vent,or a Type B vent with straight pipe between the outside termination and the space where the water
heater is installed;
C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining
without pump assist,
D. A gas supply line with a capacity of at least 200,000 Btu/hr.
§150.0(o):All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality
in Low-Rise Residential Buildings.Window operation is not a permissible method of providing the Whole Building Ventilation required in
Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§110.4(a):Any pool or spa heating system shall be certified to have:a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater;a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§110.4(b)l:Any pool or spa heating equipment shall be installed with at least 36"of pipe between filter and heater,or dedicated suction
and return lines,or built-up connections for future solar heating.
110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
§150.0(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping,filters,and valve requirements of 150.0
Residential Lighting Measures:
§150.0(k)lA: Installed luminaires shall be classified as high-efficacy or low-efficacy for compliance with Section 150.0(k)in accordance
with TABLE 150.0-A or TABLE 150.0-B, as applicable.
150.0 k 1C:The wattage of permanently installed luminaires shall be determined asspecified by§130.0(c).
150.0 k 1 D: Ballasts for fluorescent lam s rated 13 Watts or reater shall be electronic and shall have an output frequency -20 kHz.
§150.0(k)l E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume
no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not
be required to be controlled by vacancy sensors.
EnergyPro 6.3 by EnergySoft User Number:6249 ID: 14-091713 Page 13 of 14
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1R
Project Name Date
Chung Addition 9/17/2014
150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens,shall meet the applicable requirements of§150.0(k).
150.0(k)2:All switching devices and controls shall meet the requirements of§150.0 k 2.
§150.0(k)3:A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft'or 100 watts
for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all
lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also
controlled by vacancy sensors or dimmers.
§150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
§150.0(k)5: Lighting installed in bathrooms shall meet the following requirements:
A.A minimum of one high efficacy luminaire shall be installed in each bathroom; and
B.All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6: Lighting installed in attached and detached garages, laundry rooms,and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms,garages, laundry rooms, and utility rooms shall be
high efficacy,or shall be controlled by either dimmers or vacancy sensors.
EXCEPTION 1: Luminaires in closets less than 70 square feet.
EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site.
§150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact(IC)by Underwriters
Laboratories or other nationally recognized testing/rating laboratory;and have a label that certifies the luminaire is airtight with air
leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283;and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150.0(k)9A: For single-family residential buildings,outdoor lighting permanently mounted to a residential building or other buildings on
the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items
ii or iii below;and
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor,or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and
automatically reactivates the motion sensor within 6 hours
iii.Controlled by one of the following methods:
a. Photocontrol not having an override or bypass switch that disables the photocontrol;or
b.Astronomical time clock not having an override or bypass switch that disables the astronomical time clock,and
which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements:
At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9;
meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in
Section 130.5;does not have an override or bypass switch that allows the luminaire to be always ON;and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
§150.0(k)9A: For low-rise multi-family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and
outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
following requirements:
i. Shall comply with Section 150.0(k)9A; or
ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7,and 141.0.
§150.0(k)9: For low-rise residential buildings with four or more dwelling units,outdoor lighting not regulated by Section 150.0(k)9B or
Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)9D:Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall
comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7,and 141.0.
§150.0(k)10: Internally illuminated address signs shall comply with Section 140.8;OR not contain a screw-base socket,and consume
no more than five watts of power as determined according to§130.0(d).
§150.0(k)11: Lighting for residential parking garages for eight or more
vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1,
130.4, 140.6,and 141.0.
§150.0(k)12A.In a low-rise multi-family residential building where the total interior common area in a single building equals 20 percent
or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
§150.0(k)12B. In a low-rise multi-family residential building where the total interior common area in a single building equals more than
20 percent of the floor area, permanently installed lighting in that building shall:
i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6,and 141.0;and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent.The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
EnergyPro 6.3 by EnergySoft User Number:6249 ID:14-091713 Page 14 of 14