Loading...
13110079 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10230 PENINSULA AVE CONTRACTOR:RAGHUPATHI SUBBIAH PERMIT NO: 13110079 OWNER'S NAME: RAGHUPATHI SUBBIAH 10230 PENINSULA AVE DATE ISSUED:02/11/2014 OWNER'S PHONE: 6508611162 CUPERTINO,CA 95014 PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL E] COMMERCIAL E] ADDITION OF 498 S.F. TO CREATE (N) LIVING RM& License Class Lie.# DINING RM & 2 (N)BATHROOMS. REMODEL(E) BATHROOM& KITCHEN Contractor Date REVISION# 1 -REMOVE 17 S.F.OF LIVING RM AREA- 1 hereby affirm that I am licensed under the provisions of Chapter 9 ISSUED 3/6/2014 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. 1 hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$100000 1 have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:32622021.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that 1 have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. l agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS T C INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply Issued by: Date: with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. RE-ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. OWNER-BUILDER DECLARATION 1 hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, siness&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(See.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will 1 hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should 1 use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District 1 performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,25533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this V— C)44,6114 ermit is issued. Owner or authorized agent: Date: I certify that in the performance of the work for which this permit is issued,1 shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address 1 certify that I have read this application and state that the above information is correct I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date C6 CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 CUPERTINO (408) 777-3228• FAX(408)777-3333• buildingCcDcupertino.org ❑NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION/TI MREVISIO DEFERRED ORIGINAL PERMIT# 13I 1 007 PROTECT ADDRESS 10 2 -:� "to,_/'L , APN# 2/ ^ -),I-— — O 2,1 OWNER NAME R(�L`�k�fOl Su/bl�Q.l,��/ PHONE 11 -65c)-961-111Z, E-MAIL 'YSlab�ial, r� S,9,horSYS. STREET ADDRESS . r- AI'C CITY, STATE,ZIP /k, fyp%%W C* q CONTACT NAME Q �y N-_• f�MV K�.. PHONE 17/ 7!O g 6 l fill_ E MAIL ,y STREET ADDRESS 10 C "vl„',,.KA „[-,/1_ CITY,STATE,ZIP ) FAX OWNER ❑ OWNER-BUILDER w,❑ OWNERR AGENT ❑ CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME � 41 •i M}�Y� 6_ R J LICENSE NUMBER q O q ��� LICENSE TYPE BUS.LIC# COMPANY NAME 1, S wrE-MAIL l FAX AR I�.5_C1 5Wmt h @ y hon STREET ADDRESS 10 I, S �t/�3^q VYrI CITY,STATE,ZIP Ste'ol- coop, q SI Z1 PHONE L+0q 6474 ARCHITECT/ENGINEER NAME 7 LICENSE NUMBER 1 BUS.LIC# 9.0 COMPANY NAME E-MAIL / 1 Q 2O FAX STREET ADDRESS CITY,STATE,ZIP / PHONE D& 219 $L� DESCRIPTION OF WORK ' 01 L4 ax? EXISTING USE PROPOSED USE CONSTR-TYPE #STORIES USE TYPE OCC. SQ.FT. VALUATION($) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH []ATTACH #DWELLING UNITS: TIS A SECOND UNrr ❑YES SECOND STORY []YES BEING ADDED? NO ADDITION? NO PRE-APPLICATION ❑YES IF YES,PROVIDE COPY OF IS THE BLDG AN ❑YES vi`" — a TOTAL VALUATION: PLANNING APPL# ❑NO PLANNING APPROVAL LEITER EICHLER HOME? ❑NO By my signature below,I certify to each of the following: I am the property owner or autonze ag erty owner's behalf. [have read this application and the information I have provided is correct. I have read the Description of Work Ify it is accurat I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize representatives of Cupertino to ter the a -identified pro erty for inspection purposes. Signature of Applicant/Agent: Date: 0 SUPPLEMENTAL INFORMATION REQUIRED ;riaiv eHEc%+.TYE 4° ai .Rrjuclic sl iP #; _New SFD or Multifamily dwellings: Apply for demolition permit for " L7 OYER THUCOUNTER BUILDING PLAN REVIEW existing building(s). Demolition permit is required prior to issuance of building permit for new building. �1xPREss � s ��*� PtNING Ptv REvr>w _Commercial Bldgs: Provide a completed Hazardous Materials Disclosure © STAND formARD r � vORxS if any Hazardous Materials are being used as part of this project. _Copy of Planning Approval Letter or Meeting with Planning prior to ❑ 1AJORk }5 8 DIS CT7r ;a submittal of Building Permit application. � "xr� ���� <-ENVIRONMENTAI BldgApp_2011.doc revised 06/21/11 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 10230 PENINSULA AVE DATE: 03/06/2014 REVIEWED BY: MELISSA APN: 326 22 021 BP#: 13110079 `VALUATION: Iso PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY PENTAMATION USE: SFD or Duplex PERMIT TYPE: 1GENRE WORK REVISION # 1 - REMOVE 17 S.F. OF LIVING RM AREA- ISSUED 3/6/2014 SCOPE Ll NOTE: This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc . Thesefees are based on the preliminary information available and are only an estimate. Contact the De t or addn'1 info. FEE ITEMS (Fee Resolution 11-033 Eff TT 3� FEE QTY/FEE MISC ITEMS Plan Check Fee: Hourly Only? 0 Yes (j) No $0.00 hours Plan Check,Hourly Suppl. PC Fee: 0 Reg. 0 OT 0.0 1 firs $0.00 $139.00 1STPLNCK PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:) Reg. 0 OT0.0 firs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 0 Work Without Permit? 0 Yes Q No $0.00 0 Advanced Planning Fee: $0.00 Select a Non-Residential Q Building or Structure 0 Strong Motion Fee: $0.00 Select an Administrative Item Bldg Stds Commission Fee: $0.00 SUBTOTALS: $0.00 $139.00 TOTAL FEE: $139.00 Revised: 01/15/2014 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10230 PENINSULA AVE CONTRACTOR:RAGHUPATH]SUBBIAH PERMIT NO: 13110079 OWNER'S NAME: RAGHUPATHI SUBBIAH 10230 PENINSULA AVE DATE ISSUED:02/11/2014 OWNER'S PHONE: 650861 1162 CUPERTINO,CA 95014 PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL E] COMMERCIAL ❑ ADDITION OF 498 S.F. TO CREATE(N)LIVING RM & License Class Lic.# DINING RM &2(N)BATHROOMS. REMODEL(E) BATHROOM Contractor Date &KITCHEN I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: 1 have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$100000 1 have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:32622021.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION 1 certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PE ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS F >r ED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply sue Date: with all non-point source regulations per the Cupertino Municipal Code,Section 918. E-ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,1 agree to remove all new materials for inspection. OWNER-BUILDER DECLARATION Signature of Applicant: Date: I here y affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE onstruct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous 1 have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,25533,and 255534. Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: t'�'` Date: O )d m e rt is issued. .0 certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must 1 hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that 1 have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature rv1'w Date CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION \O 10300 TORRE AVENUE •CUPERTINO,CA 95014-3255 n CUPERTINC} (408)777-3228• FAX(408)777-3333•building(Dcugertino.org �— ❑NEW CONSTRUCTION 5?/ADDITION ALTERATION/TI ❑ REVISION/DEFERRED ORIGINAL PERMIT# PROJECT ADDRESS I O t7 Pe�Cn S kta Ave Q APN# 2 1 Z Z 0 Z, OWNERNAME 9- 0.3h1Af1%rhC SU -4coth PHONE bSO $t' II /ZO E-MAIL RSUB6IA)4_ syHoPsys •[� Cf,l V '17 Z tnt a w}'kA v 1 C "1 STREET ADDRESS 1 p 23 O Qe V>nS A'V'C CITY, STATE,ZIP (1 �A �,;.� iA_ 6�pI FAX CONTACT NAME Da51,�wr�6L( S".6LQ� PHONE C5 0 9 6 I I6Z E-MAIJL�SugQiIAH � Syn/aP�`/S' Ce STREET ADDRESS 1� �M CITY,STATE,ZIP FAX 2, 10 QtnZVnSV.&_ Avg -e�.y .►w CAN- 'I "14- OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑CON'TRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE DESCRIPTION OF WORK N« XnaJ G _ , ,•h� )C.4:N,_,__ EXISTING USE PROPOSED USE CONSTR.TYPE #STORIES b s I Z 1 4 S A C1nQ USE TYPE OCC. SQ.FT. VALUATION(S) EXISTG NEW FLOOR DEMO TOTAL AREA ?3 6 AREA (,I.Cr AREA NET AREA )-134 -13 4 s BATHROOM KITCHEN OTHER T REMODEL AREA pl C` REMODELAREA IQ.O sV REMODELAREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH ❑ATTACH #DWELLING UNITS: IS A SECOND UNIT []YES SECOND STORY ❑YES BEING ADDED? 2-NO ADDITION? 21*10 PRE-APPLICATION ❑YES IF YES,PROVIDE COPY OF IS THE BLDG AN ❑YES TOTAL VALUATION: PLANNING ADPL# [:]NO PLANNING APPROVAL LETTER EICHLER HOME? ❑No By my signature below,I certify to each of the following: I am the property owner or authorized agent t on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and rify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to uilding construction. I authorize representatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant�krent: Date: 1 Z 1 13— SUPPLEMENTAL 3SUPPLEMENTAL INF ATION REQUIRED PLAN CHECK TYPE ROUTING SLIP ; New SFD or Multifamily dwellings: Apply for demolition permit for ❑ "OVER-THE-coUNTER ❑ BUI LING PLAN'REviEW, existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ ;XPRESS ❑ PLANNING PLAN REVIEW Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD ❑ PUBLIC WORKS for n if any Hazardous Materials are being used as part of this project. ❑ "LARGE ❑ FIRE DEPT Copy of Planning Approval Letter or Meeting with PIanning prior to ❑ I\iAJOR ❑ sANrrARY sEwERnISTxICT submittal of Building Permit application. ❑ ENVIRONMENTAL HEALTH B1dgApp_2011.doc revised 06/21/11 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: I 0 V3 C) M'kl S v l; DATE: 11/08/2013 REVIEWED BY: Sean APN: Q. OZ,I BP#: �v� *VALUATION: $100,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY 2nd Unit? Yes �No PENTAMATION USE: SFD or Duplex OTC? Yes 1 R3SFDADD No PERMIT TYPE: WORK Constructa 498 sg ft addition; kitchen and bathroom remodel. SCOPE OCCUPANCY TYPE: TYPE OF FLR AREA PC FEES PC FEE ID BP FEES BP FEE ID CONSTR. s.f. R-3 (Custom) II-B,(11-B,IV,V-B 498 $1,579.00 IADDPLCK $1,284.00 lADDINSP TOTALS: 498 $1,579.00 $1,284.00 MECH,HOURLY O Yes G No PLUMB,HOURLY O .Yes Q No ELEC,HOLTRLY O Yes Q No NOTE.This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). These ees are based on the preliminar information available and are on an estimate. Contact the De t or addn'l info. FEE ITEMS Fee Resolution 11-053 Eff. 7/1/132 FEE QTY/FEE MISC ITEMS Plan Check Fee: $1,579.00 200 1 s.£ Remodel,Kitchen(<=300 sf) Suppl.PC Fee: Q Reg. O OT 0.0 lirs $0.00 $626.00 1REMRESKIT PME Plan Check: $0.00 100 s.f. Remodel,Bath(<=300 sf) PennitFee: $1,284.00 $626.00 IRENIRESBAT Suppl. Insp. Fee:Q Reg. O OT p,Q hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 O Work Without Permit? O Yes D No $0.00 0 Advanced Planning Fee: IPLLONGR $69.72 Select a Non-Residential E) 'e' iitBuilding or Structure O lFt3;�T.l"' : Strome Motion Fee: 1BSEISMICR $10.00 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $4.00 SUBTOTALS: $2,946.72 $1,252.00 TOTAL FEE: F$4,198.72 Revised: 10101/2013 Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014-3255 C U P E RT I N O Telephone: 408-777-3228 Fax:408-777-3333 CONTRACTOR/ SUBCONTRACTOR LIST JOB ADDRESS: 2- i n 5L&Lx Ne— PERMIT# ` 00 OWNER'S NAME: RAC-74Vpr--r PHONE# 6 yjo GENERAL CONTRACTOR: BUSINESS LICENSE# ADDRESS: CITY/ZIPCODE: *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Date Please check applicable subcontractors and complete the following information: SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring/ Carpeting Linoleum/Wood Glass/Glazing Heating Insulation Landscaping Lathing Masonry Painting/Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile 1 L o 1 �- Owner/C or ignature Date Building Department City Of Cupertino 10300 Torre Avenue Cupertino,CA 95014-3255 C U P E RT I N O Telephone: 408-777-3228 Fax: 408-777-3333 CONTRACTOR/ SUBCONTRACTOR LIST JOB ADDRESS: 102,30 Per Z 11 +✓e- PERMIT# I i I D o'7q OWNER'S NAME:"hU-raj-a 5u bbZ,b KaLCa. %k PHONE# 6 o '361 1 ( 6-2— GENERAL CONTRACTOR: ALL"e, BUSINESS LICENSE# 2- 6"'7 7 ADDRESS: l o i 4 5 ®E PrN"LA D CITY/ZIPCODE: Suv, 7o5eC pr q51 *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Date Please check applicable subcontractors and complete the following information: SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # f Cabinets & Millwork Li.'S (,rsns 1irq,,;l.�;� r2 odQ', ZSS 6 7 Cement Finishing [a;5 tq-,15Hw4h:9- "vd-e (A 2-S6 7-7 ✓ Electrical ,,.,h; Ry,�.,,,-�t.a,, Z$67 "� V Excavation ,�}�; C w a z$617 Fencing Flooring/ Carpeting A -S cm w-,L� Qe - 2-9677 Linoleum /Wood 4t�s �yy,,�,�j� o d�Xi L$ 6'7 '7 f Glass/ Glazing Q p L� J Heating 1kt�5 yvy, /L�,•,,o,e�(C Z g 6'7 InsulationS v 2- 611 Landscaping Lathing Masonry Painting/Wallpaper A-i s Lznn SyyLt� Y, ke"U 2- Paving Paving V Plastering /�Li.S Lc-nS YY+c-, ZS3 °7-7 -V/ Plumbing y tea,v,� 42,m- 2-96-7-7 Roofing Cltv a Z g 67 7 Septic Tank Sheet Metal Sheet Rock t ;s , y, y , ,�,rn o Z 86'7� V Tile Lrn�' �-ti, Re-'n 2-3 6 7 7 o � �o z 1 2,01 Owner/ r Signature Date OWNER-BUILDER DISCLOSURE FORM COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE-CUPERTINO, CA 95014-3255 (408)777-3228• FAX(408)777-3333• building(c-)cuoer lno.org CUPERTINO Dear Property Owner(s): An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at: SITE ADDRESS 230 Qein�nskta 4v2 APN 32 -L 10 2 BP# 3 OWNER NAME �0.9�1�1p0.f11�L S4�v�•!� OWNER ADDRESS J ,�' DESCRIPTION OF WORK: ff�� Q 0�7Y+1 .t F� �1X* sakihk$ -r-,. OZ ^M oA44 Lt-qY s F r "cw k-64:0- We .,a r:0,,,We are providing you with an Owner-Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner-Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you,the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION (DIRECTIONS:Please read and initial each statement below to signify you understand or verify this information.) �- - I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner- Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. 2. I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. 3. I understand as an "Owner-Builder" I am the responsible party of record on the permit. I understand that I may r--pfYtect myself from potential financial risk by hiring a licensed Contractor and having the permit flied in his or her name instead of my own. 4. 1 understand Contractors are required by law to be licensed and bonded in California and to list their license nu bers on permits and contracts. 5. 1 understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the t I value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer"understate and federal law, * . I understand if I am considered an "employer" under state and federal law, I must register with the state and r1al government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. 7. 1 understand under California Contractors' State License Law, an Owner-Builder who builds single-family resi ntial structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for any fi ancial or personal injuries sustained by any subsequent owner(s)that result from any latent construction defects in the workmanship or materials. ONA7e7Bllilde7,Foi771 2010.doc revised 04/14/10 E . I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration,the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. A. I am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that I am parry legally and financially responsible for proposed construction activity at the site address listed above. loll i 11. 1 agree that, as the parry legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner-Builders as well as employers. 2. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license,the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner-Builder and wish to hire Contractors,you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. CONSTRUCTION LENDING AGENCY (DIRECTIONS:Please complete the following construction lending agency information.) I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097 Civ.) Lender Name: Lender Address: Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note:A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the propeyy owner's si nature. Property Owner's Signature: Date: 01,1101?a! --------------------------------------------------------------------------------------------------------------------------------------------- (NOTE: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner-Builder). AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s)to act as my agent(s)to apply for, sign, and file the documents necessary to obtain an Owner-Builder Permit for my project. Scope of Construction Project(or Description of Work): Project Location or Address: Name of Authorized Agent: Tel No Address of Authorized Agent: declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and cerci y its accuracy. Note:A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: 04�7le7-Biiilde7Forn: 2010.doc revised 04/14110 BUILDING ENERGY ANALYSIS REPORT PROJECT: Raghupathi Subbiah& Kalaivani Raghupthi 10230 Peninsula Avenue Cupertino, CA Project Designer: E. NOV2013 Report Prepared by: Arash Firouzjaei Advance Construction Engineering 434 Camille Cir. San Jose, CA 95134 FFIC two �Aw� f i Job Number: Date: 11/10/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report.This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft,LLC—www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number 8605 Run Code:2013-11-10T13:31:33 ID: PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Raghupathi Subbiah& Kalaivani Raghupthi ❑ Multi Family m Existing+Addition/Alteration 11111012013 Project Address California Energy Climate Zone Total Cond.Floor Area Addition #of Stories 10230 Peninsula Avenue Cupertino CA Climate Zone 04 1,234 498 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. 0 Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (f Features (see Part 2 of 5) Status Wall Wood Framed None 465 Existing Door Opaque Door None 40 Existing Floor Wood Framed w/Crawl Space None 736 Existing Roof Wood Framed Attic R-11 736 Existing Wall Wood Framed R-13 474 New Floor Wood Framed w/Crawl Space R-19 498 New Roof Wood Framed Attic R-30 494 New FENESTRATION U- Exterior Orientation Area(ff) Factor SHGC Overhang Sidefins Shades Status Front(SW) 35.0 0.710 0.73 none none Bug Screen Existing Front(SW) 17.5 0.710 0.73 none none Bug Screen Removed Left(NW) 41.0 0.710 0.73 none none Bug Screen Existing Rear(NE) 60.0 1.190 0.83 none none Bug Screen Removed Right(SE) 12.0 0.710 0.73 none none Bug Screen New Right(SE) 17.5 0.710 0.73 none none Bug Screen Existing Right(SE) 17.5 0.710 0.73 none none Bug Screen Removed Left(NW) 72.0 0.340 0.32 none none Bug Screen New Rear(NE) 60.5 0.340 0.32 none none Bug Screen New Right(SE) 84.0 0.340 0.32 none none Bug Screen New Skylight 4.0 0.550 0.67 none none None New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 82%AFUE No Cooling 13.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 6.0 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number.8605 RunCode:2013.11-10T13:31:33 ID: Page 3 of 12 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Raghupathi Subbiah& Kalaivani Raghupthi ❑ Multi Family m Existing+Addition/Alteration 11/10/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist.These items require special written justification and documentation,and special verification to be used with the performance approach.The enforcement agency determines the adequacy of the justification,and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System Furnace without A/C does not include a cooling system,field verification is not necessary. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. Ener Pro 5.1 b V Ener Soft User Number:8605 Run Code:2013-11-10T13:31:33 ID: Pa e 4 of 12 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Raghupathi Subbiah& Kalaivani Raghupthi ❑ Multi Family 10 Existing+Addition/Alteration 11/10/201 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 61.97 46.66 15.31 Space Cooling 42.01 34.50 7.51 Fans 18.28 14.79 3.49 Domestic Hot Water 28.47 28.47 0.00 Pumps 0.00 0.00 0.00 Totals 150.73 124,43 26.31 Percent Better Than Standard: 17.5 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (Sw)225 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (SM 216 35 Fuel Available at Site: Natural Gas (NM 434 113 Raised Floor Area: 1,234 (NE) 216 61 Slab on Grade Area: 0 (SE) 434 114 Average Ceiling Height: 8.0 Roof 1,234 4 Fenestration Average U-Factor: 0.46 TOTAL: 326 Average SHGC: 0.45 Fenestration/CFA Ratio: 26.4% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author �1 Company Advance Construction Engineering 11/1012013 Address 434 Camille Cir. Name Arash Firouzjaei City/State/ZipCity/State/Zip San Jose,CA 95134 Phone Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Address I o23a �" "'Y'�"r" Name �GLtv�rt4GM� i �t4 l �� l?i City/State/Zip &-tf"Wo ( al 5'14 Phone 65a-90 -1 )6-1— Signed License# Date EnemyPro 5.1 by Ener Soft User Number:8605 RunCode:2013-11-10713:31:33 ID: Page 5 of 12 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Raghupathi Subbiah& Kalaivani Raghupthi ❑ Multi Family 10 Existing+Addition/Alteration 11/10/201 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 109 0.356 None 225 90 Existing 4.3.1-A1 Existing Portion Door 20 0.500 None 225 90 Existing 4.5.1-A4 Existing Portion Wall 35 0.356 None 225 90 Remove 4.3.1-A1 Existing Portion Wall 217 0.356 None 315 90 Existing 4.3.1-A1 Existing Portion Wall 30 0.356 None 45 90 Existing 4.3.1-A1 Existing Portion Wall 126 0.356 None 45 90 Removec 4.3.1-A1 Existing Portion Wall 109 0.356 None 135 90 Existing 4.3.1-A1 Existing Portion Door 20 0.500 None 135 90 Existing 4.5.1-A4 Existing Portion Wall 83 0.356 None 135 90 Removec 4.3.1-A1 Existing Portion Floor 736 0.097 None 0 180 Existing 4.4.1-A1 Existing Portion Roof 736 0.079 R-11 0 18 Existing 4.2.1-A2 Existing Portion Wall 52 0.102 R-13 225 90 New 4.3.1-A3 Existing Portion Wall 104 0.102 R-13 315 90 New 4.3.1-A3 Existing Portion Wall 126 0.102 R-13 45 90 New 4.3.1-A3 Existing Portion Wall 192 0.102 R-13 135 90 New 4.3.1-A3 Existing Portion Floor 498 0.037 R-19 0 180 New 14.4.1-A4 Existing Portion FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC2 Azm Status Glazing Type Location/Comments 1 Window 17.5 0.710 Default 0.73 Default 225 Existing Existing Window Existing Portion 2 Window 17.5 0.710 Default 0.73 Default 225 Existing Existing Window Existing Portion 3 Window 17.5 0.710 Default 0.73 Default 225 Removed Existing Window Existing Portion 4 Window 17.5 0.710 Default 0.73 Default 315 Existing Existing Window Existing Portion 5 Window 17.5 0.710 Default 0.73 Default 315 Existing Existing Window Existing Portion 6 VVIndow 6.0 0.710 Default 0.73 Default 315 Existing Existing Window Existing Portion 7 Window 17.5 1.190 Default 0.83 Default 45 Removed Removed Window Existing Portion 8 Window 17.5 1.190 Default 0.83 Default 45 Removed Removed Window Existing Portion 9 Window 25.0 1.190 Default 0.83 Default 45 Removed Removed Window Existing Portion 10 Window 6.0 0.710 Default 0.73 Default 135 New Existing Window Existing Portion 11 Window 6.0 0.710 Default 0.73 Default 135 New Existing Window Existing Portion 12 Window 17.5 0.710 Default 0.73 Default 135 Existing Existing Window Existing Portion 13 Window 17.5 0.710 Default 0.73 Default 135 Removed Existing Window Existing Portion 14 Window 36.0 0.340 NFRC 0.32 NFRC 315 New New Window Existing Portion 15 Window 36.0 0.340 NFRC 0.32 NFRC 315 New New Window Existing Portion 16 Window 17.5 0.340 NFRC 0.32 NFRC 45 New New Window Existing Portion (1) U-Factor Type: 116-A=Default Table from Standards,NFRC=Labeled Value 2 SHGC Type: 116-B=Default Table from Standards,NFRC=Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len H t LExt REA Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 1 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number 8605 RunCode:2013-11-10T13:31:33 ID: Pae 6 of 12 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-'1 R Project Name Building Type m Single Family ❑Addition Alone Date Raghupathi Subbiah& Kalaivani Raghupthi ❑ Multi Family m Existing+Addition/Alteration 11111012013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 494 0.031 R-30 0 18 New 4.2.1-A20 Existing Portion FENESTRATION SURFACE DETAILS ID Type Area LI-Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 43.0 0.340 NFRC 0.32 NFRC 45 New New Window Existing Portion 18 Window 36.0 0.340 NFRC 0.32 NFRC 135 New New Window Existing Portion 19 Window 36.0 0.340 NFRC 0.32 NFRC 135 New New Window Existing Portion 20 Window 6.0 0.340 NFRC 0.32 NFRC 135 New New Window Existing Portion 21 Window 6.0 0.340 NFRC 0.32 NFRC 135 New New Window Existing Portion 22 Skylight 4.0 0.550 Default 0.67 Default 0 New Skylight Existing Portion (1) U-Factor Type: 116-A=Default Table from Standards,NFRC=Labeled Value 2 SHGC Type: 116-B=Default Table from Standards,NFRC=Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 None 1.00 EnergyPro 5.1 by Ener Soft User Number:8605 RunCode:2013-11-10T13:31:33 ID: Pae 7 of 12 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name Building Type la Single Family ❑Addition Alone Date Raghupathi Subbiah& Kalaivani Raghupthi ❑Multi Family m Existing+Addition/Alteration 11!10/201 BUILDING ZONE INFORMATION Floor Area ft System Name Zone Name New Existinq I Altered Removed Volume Year Built HVAC System Existing 736 5,888 1960 Addition 498 3,984 Totals 498 01 736F 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System 1 Central Furnace 82%AFUE No Cooling 13.0 SEER Setback Existing HVAC DISTRIBUTION Duct Ducts System Name Heating Coolie Duct Location R-Value Tested? Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 6.0 ❑ Existing WATER HEATING SYSTEMS Ext. Rated Tank Energy Standby Tank Input Cap. Factor Loss or Insul. R- S stem Name Qty. Type Distribution Btuh al or RE Pilot Value Status Default Gas Prior to 1999 1 Small Gas No Pipe Insulation 28,000 50 0.53 n1a n/a Existing MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Hot Water Piping Length ft � 0 -moo Pipe Pipe Insul. Control Qty. HP Plenum Outside Buried Q—I System Name Len th Diameter Thick. Ener Pro 5.1 by Ener Soft User Number:8605 Run Code:2013-11-10T13.31:33 ID: Pae 8 of 12 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF-1 R Project Name Date Raghupathi Subbiah& Kalaivani Raghupthi 11111012013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance(CF-1 R,CF-1 R-ADD,or CF- 1 R-ALT Form)shall supersede the items marked with an asterisk(')below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products(except field-fabricated windows) have a label listing the certified U-Factor,certified Solar Heat Gain Coefficient SHGC ,and infiltration that meets the requirements of 10-111(a). 117: Exterior doors and windows are weather-stripped;all joints and penetrations are caulked and sealed. i 18(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i):The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of§118(1)when the installation of a Cool Roof is specified on the CF-1 R Form. *§1 50 a :Minimum R-19 insulation in wood-frame ceiling orequivalent U-factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§1 50 c :Minimum R-13 insulation in wood-frame wall orequivalent U-factor. 150(d):Minimum R-13 insulation in raised wood-frame floor orequivalent U-factor. §150(f):Air retarding wrap is tested, labeled,and installed according to ASTM E1677-95(2000)when specified on the CF-1R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1):Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%;water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory-built fireplaces have a combustion outside air intake,which is at least six square inches in area and is equipped with a with a readily accessible,operable,and tight-fitting damper and or a combustion-air control device. §150(e)2:Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket,when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning,Water Heating and Plumbing System Measures: §110-§113:HVAC equipment,water heaters, showerheads,faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5:Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release valve, backflow prevention,pump isolation valve,and recirculation loop connection requirements of§113(c)5. §115:Continuously burning pilot lights are prohibited for natural gas:fan-type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt),and pool and spa heaters. 150(h):Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i):Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A:Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks,such as storage tanks or backup tanks for solar water-heating system,or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank,non-recirculating systems,and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2:Cooling system piping(suction,chilled water,or brine Iines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems>15 psi, meets the requirements of Standards Table 123-A. 150 3A: Insulation is protected from damage,including that due to sunlight, moisture,equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §150(j)4:Solar water-heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number.8605 RunCode:2013-11-10T13:31:33 /D: Page 9 of 12 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Raghupathi Subbiah& Kalaivani Raghupthi 11/10/2013 §150(m)1:All air-distribution system ducts and plenums installed,are sealed and insulated to meet the requirements of CMC Sections 601, 602,603,604, 605 and Standard 6-5;supply-air and return-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space.Openings shall be sealed with mastic,tape or other duct-closure system that meets the applicable requirements of UL 181,UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities,support platforms for air handlers,and plenums defined or constructed with materials other than sealed sheet metal,duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D:Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8:Gravity ventilating systems serving conditioned space have either automatic or readily accessible,manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture,equipment maintenance,and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10:Flexible ducts cannot have porous inner cores. §150(o):All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings.Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a):Any pool or spa heating system shall be certified to have:a thermal efficiency that complies with the Appliance Efficiency Regulations;an on-off switch mounted outside of the heater;a permanent weatherproof plate or card with operating instructions;and shall not use electric resistance heating ora pilot light. §114(b)1:Any pool or spa heating equipment shall be installed with at least 36"of pipe between filter and heater, or dedicated suction and return lines,or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems or equipment meet the pump sizing,flow rate,piping,filters,and valve requirements of§150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by§150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by§130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line- voltage lamp holder;OR shall be rated to consume no more than five watts of power as determined by§130(d),and shall not contain a medium screw-base socket. §150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of§150(k). 150(k)7:All switching devices and controls shall meet the requirements of§150(k)7. §150(k)8:A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION:Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50%high efficacy requirement when:all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer,energy management system (EMCS), or a multi-scene programmable control system;and all permanently installed luminaries in garages, laundry rooms,closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual-on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoR User Number:8605 RunCode:2013-11-10713:31:33 ID: Page 10 of 12 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Raghupathi Subbiah& Kalaivani Raghupthi 11111012013 §150(k)10:Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms,closets and utility rooms shall be high efficacy. EXCEPTION 1:Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of§119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual-on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens,bathrooms,garages, laundry rooms, closets,and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of§119,or by a manual- on occupant sensor that complies with the applicable requirements of§119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with§150 k 11. §150(k)l2:Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact(IC)by Underwriters Laboratories or other nationally recognized testing/rating laboratory;and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283;and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3:Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches,which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch,a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls:a photocontrol not having an override or bypass switch that disables the photocontrol;OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock;OR an energy management control system(EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2:Outdoor luminaires used to comply with Exceptionl to§150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool,water features,or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148;OR not contain a screw-base socket, and consume no more than five watts of power as determined according to§130(d). §150(k)15:Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130,132,134,and 147.Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134,and 146. §150(k)16:Permanently installed lighting in the enclosed,non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 byEnergySoft User Number.8605 RunCode:2013-11-10T13:31:33 ID: Page 11 of 12 ENERGY USE AND COST SUMMARY ECON-1 Project Name Date Raghupathi Subbiah& Kalaivani Raghupthi 11/10/2013 Rate: PG&E E1 P Fuel Type: Electricity STANDARD PROPOSED MARGIN Energy Peak Energy Peak Energy Peak Use Demand Cost Use Demand Cost Use Demand Cost (kWh) (kW) ($) (kWh) (kW) ($) (kWh) (kW) ($) Jan 163 2 20 125 1 15 38 2 5 Feb 149 5 18 113 4 14 36 1 4 Mar 120 3 15 91 3 11 28 0 3 Apr 188 4 23 147 4 18 41 0 5 May 223 7 27 175 6 21 48 1 6 Jun 385 7 47 350 7 43 35 0 4 Jul 462 7 57 414 6 51 49 1 6 Aug468 8 57 397 7 49 71 0 9 Sep 351 9 43 259 8 32 92 1 1 11 Oct 177 5 22 126 5 15 51 1 6 Nov 149 3 18 107 2 13 42 0 5 Dec 157 1 19 124 1 15 33 0 4 Year 2,991 9 366 2,426 81 297 565 1 69 CO2 2,064 lbs/yr 1,674 lbs/yr 390 lbs/yr Rate: PG&E G1 P Fuel T e: Natural Gas STANDARD PROPOSED MARGIN Energy Peak Energy Peak Energy Peak Use Demand Cost Use Demand Cost Use Demand Cost (therms) (kBtu/hr) ($) (therms) (kBtu/hr) ($) (therms) (kBtu/hr) ($) Jan 127 63 141 104 56 111 24 8 30 Feb 91 52 96 73 47 74 18 5 22 Mar 80 48 82 65 43 64 15 5 19 Apr 66 38 65 53 j 35 52 13 3 12 May 29 28 33 25 27 27 4 1 5 Jun 22 31 23 20 29 21 1 2 2 Jul 20 10 21 20 5 20 0 5 0 Aug19 12 20 19 5 20 0 7 0 Sep 21 18 22 19 14 20 1 4 2 Oct 33 48 37 28 37 31 4 11 5 Nov 92 54 97 74 49 75 18 6 22 Dec 125 66 139 102 58 110 23 8 29 Year 725 66 775 604 58 627 121 8 147 CO2 8,450 lbs/yr 7,036 lbs/yr 1,414 lbs/yr Annual Totals Energy Demand Cost Cost/s ft Virtual Rate Electricity 2,426 kWh 8 kW $ 297 $ 0.24/S ft $ 0.12 /kWh Natural Gas 604 therms 58 kBtu/hr $ 627 $ 0.51 /s ft $ 1.04 /therm Total $ 924 $ 0.75/s ft Avoided CO2 Emissions: 1,804 lbs/yr EnergyPro 5.1 by EnergySoft User Number.'8605 Run Code:2013-11-10T13:31:3 ID: Page 12 of 12