Loading...
B-2017-1179CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: ]CONTRACTOR: PERMIT NO: B-2017-1179 10268 PARKWOOD DR APT 6 CUPERTINO, CA (326 27 037) THERMAL OWNER'S NAME: AVERY GLENBROOK LP OWNER'S PHONE: 650-961-8330 LICENSED CONTRACTOR'S DECLARATION License Class C-4, C -1 0;C -36-C-38 Lic. #256057 Contractor THERMAL MECHANICAL Date 01/31/2018 I hereby affirm that I am licensed under, the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: m. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by C Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify qnd keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. 1 1 is I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: m. I, as owner of the properly, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Seo.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject'to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date 7/26/2017 SANTA CLARA, CA 95054 DATE ISSUED• 07/26/2017 PHONE NO: (408) 988-8744 BUILDING PERMIT INFO• X BLDG X ELECT X PLUMB X MECH X RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION BLDG #4/UNIT#6; ADD (N) A/C; REPLACE FURNACE, SAME LOCATION, (I) WASHER AND DRYER HOOK UPS; (I) ELECTRICAL SERVICE (70 AMP); (I) GAS LINE FOR STOVE, (I) RECEPTACLE OUTLETS, (N) LIGHT; (N) BATHROOM EXHAUST FANS. Sq. Ft Floor Area: I Valuation: $20000.00 "N Number- Occupancy Type: 326 27 037 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by Abby yende Date: 07/26/2017 RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: 7/26/2017 ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and �7 the Health & Safety Code n. 55p) 25533, a d 25534. Owner or authorized agent: Date: 7126/2017 CON TRV/CeTIONLENDIINGAGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097 Civ C ) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 10300 TORRE fi�yENUE QUPERTINO, CA 95014-3255 (408) 777-3228 6,1`6408 1 77-3333 • building Acupertino.org .p� LJ NEW CONSTRUCTION ❑ ADDITION , ® AZ '1 3ATION / TI ❑ REVISION / DEFERRED ORIGINAL PERMIT # PROJECT ADDRESSAPN # 10268 Packwood DR, BLDG 41 l OWNERNAME - ,.as.., PHONE E-MAIL Avery Glenbrook LLC 650-961-8330 avery@pacbell.net STREET ADDRESS CITY, STATE, ZIP - FAX 130 East Dana Street Mt. View, CA 94041 650-961-0571 CONTACT NAME Rob Moyer PHONE 408-593-8115 E� rmoyer@thermalmech.com STREET ADDRESS425 Aldo ave. - CITY, STATE, ZIP FAX 408-988-0233 - Santa Clara, CA 95054 ❑ OWNER ❑ OWNER -BUILDER ❑i OWNER AGENT IR CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER. ❑ TENANT CONTRACTORNAME Thermal MSC LICENSE NUMBER 256057 LICENSE TYPE BUS.LIC# 299 Mechanical C-4,10,20,36,38 COMPANY NAME Thermal Mechanical E-MAIL rmoyer@thermalmech.com FAX 408-988-0233 STREET ADDRESS 425 Aldo ave. CITY, STATE, ZIP Santa Clara, CA 95054 PHONE 408-988-8744 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME _ - E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OFWORK add new AC, replace furnace in same location, (N) washer/dryer hook ups, (N) electrical panel (70 AMP), (N) gas line for stove, (N) electrical outlets, (N) light, (N) bathroom exhaust fan EXISTING USE PROPOSED USE CONSTR. TYPE # STORIES USE. TYPE I OCC.. I SQ.FT. I VALUATION ($) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NETAREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA. TOTAL DECK/PORCH AREA GARAGE AREA: DETACH ❑ ATTACH #DWELLINGUNITS: IS A SECOND UNIT ❑YES SECONDSTORY [YES BEUNGADDED? ❑NO ADDITION? ❑NO PRE APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDGAN ❑ YES UECVEDBS"� TOT VALUATION: PLANNINGAPPL# []NO PLANNING APPROVAL LETTER EICHLER HOME? []NO By my signature below, I certify to each of the following: I am the property owner or authorize agent to a ; t on the 4operty owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building constru on. I authorizerepresentativesof Cupertino to enter the above -identified property for inspection purposes. Signature of Applicant/Agent: L �� r��^ Dater _ New SFD or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building permit for new building. _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure form if any Hazardous Materials are being used as part of this project. Copy of Planning Approval Letter or Meeting with Planning prior to submittal of Building Permit application.' BldgApp_201 1. doc revised 06121111 x. : SMOKE / CARBON MONOXIDE .ALARMS • • . OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION CUPERTINO 10300 TORRE AVENUE• CUPERTINO,CA 95014-3255 (408)777-3228• FAX(408)777-3333• buildinq(a cupertino.orq ' s ,U a! ^.F",.'n :"b '� s r #s,S ''dYk yc' x q,aY.x irt 5 �} .✓t' 4 a5�.t C"S F�4 yk i ''� 4 .r f y j f .i� �, p �^ 7{z 'r �..s �'y,1{- i z ✓f v x. S"Ps ,F� Y '#i'¢ C L a s � y �.. PEItI4I 11`CAVI OT;SE FI A€�Ii�A IiN�'II��U CERTIFI AT HS S BEEN t u ` • ��u.�k,19..5 E�'l%[Rt�S.n. a-�FTSii ..5� k 11� ' �, C®�'IP TT D Sli \ D 'TIS TiTR ED'i€� �1 B DINND .SION� , � " "� y`" ,e,.' ,.r ' 'S.e'k,1 d a 'u'' ayy,�2''`,k-''t - kilo' a .L 'M-VS:i£ ?-: i3s it .. ',�': rx!5..•.�.r....."".'3T,r'°`R,. �s,7'� 'ti ex^.-sTMxnF:�;,resrxr.;ra5cx�rn^fc�c�.,,�3e� ^,x��,.g.�="�'f„^„"^ :.s�^aaz;�aaM' PURPOSE `Phis affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where ho interior access for inspections are required. GENERAL INFORMATION . Existing single-family and multi-family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms..When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM;__'' Outside of each separate sleeping area in the immediate vicinity of X X", the bedroom(s) On every level of a dwelling unit including basements _ X Within each sleeping room Carbon Monoxide alarms are not required in dwellings which donot contain fuel-burning appliances and,tlnat do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. ; Power Supply: In dwelling units with no commercial.power supply, alarm(s) may be solely battery.operat�d.., In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic,.basement or cr1nri' !' • space.Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required'fOr alarms which must be connected to the building wiring. As owner of the above-referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms specified below have been tested and are operational, as of the date signed below. Address: /Oz e, e r Q �c.buepg1 Or. L/ Permit No.4.-z617 /) ? Specify Number of Alarms: # Smoke Alarms: Z #Carbon Monoxide Detectors: I have read and a ree to comp/ with the nd conditions of this statement Owner(or Owner Agent's)Name: 34MVf G 4/ gZZO Signature Dat1/ /7 Contractor Name: 5 J ��e �( 560 Signature ' � Lica Date:?/3o/./ 7 { (,...,1 ...,a r•n r. , a a n iii/, MATER-CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION CUPERTINO10300 TORRE AVENUE• CUPERTINO, CA 95014-3255 ' (408)777-3228•FAX(408)777-3333• buildino a(�cupertino.org Owner NameU flr;? , L. L C / Permit No. /— tl/7_// 79 Address /02-0 F Pai L /D . 11'4, 1. Is.your real property a registered historical site? ❑ Yes Civil Code Sections 11,01.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. No Go to Question 2. 2. Does'your real property have a licensed plumber certifying that,due to the age or configuration of the property or its ,plumbing,installation of water-conserving plumbing fixtures is not technically feasible? Yes Civil Code Sections 1101.1 through 1101.8 do not apply.' ( The licensed plumber's,certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. ❑ No Go to Question 3. 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. No Go to Question 4. 4. Is your real'property built and available for use or occupancy on or before January.1, 1994? ❑ No MY real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of forth. Yes My real property is built andavailable for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. 5. Please check ONE of the following: ❑ My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014,building alterations or improvements shall require all non-compliant plumbing fixtures. to be replaced with water-conserving plumbing fixtures throughout the building.On or before January 42017,all non- compliant;;plumbing fixtures shall be replaced with water-conserving plumbing fixtures (regardless of whether • property undergoes alterations or improvements). My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014,specified building alterations or improvements shall require non-compliant ' plumbing fixtures to be replaced with water-conserving plumbing fixtures. • On or before January 1,2019,all non-compliant plumbing fixtures shall be.replaced with water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). El My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014,specified building alterations or improvements shall require non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January .1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). I,as the owner,or owner's agent of this property,certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior.;to date specified above with water-conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101','.8,the current California Plumbing Code and California Green Building Standards Code,and manufacturer's. installation requirements, and that the water-conserving plumbing fixtures comply with the requirements as indicated in the table on the following .age. Owner or Owner Agent's Signature: 7,3M6' PC/14.1&.0) Date: 740h 'I .• Upon completing and signing this Certificate,please return it to the Building Division in order to final your building permit. • SB407 2015.doc revised 08/26/15 • • � a'I7L�liX l3�,,1��3.1W 1. M 3A.B�i13aIL'�Y7Jl7 n.Y.1LL' 1.31`li,s ?, n is � �r i t FtStEitifF ' WP s4" b,, a1-501-1 * litr gag x , � E 5 e x' t .`�'' < z�j '� j �'. �k s »,'`� ��r- 31�rev>>r �r�a �a`esv1" �,.,- : � "�° w$n. vwazrts.;!'�r.� .�z. .a.•: .. ,roxm.,zr�m,,m�res� •.r>"raxc+gwnsmmez ss-raz:x-uew�n.�.vxvsraxxn.u.�.azs�er+ae,:�x.•�-ewn�*m'sms�xc�.•a• Non-Compliant • Water-Conserving Plumbing Fixture Plumbing Fixture1 (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type 2013 CPC Ch.4 2013 CPQ Ch. 4 2013 CPC Ch.4 Water Usage 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 (Flow Rate Single-Family Multi-Family Commercial Residential Residential Water Closets Exceed'1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets; 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush) Urinals Exceed 1.0 Gallons/flush 0.5 gallons/flush ; Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSene Specification for.Showerheads (A hand-held showeriis considered a showerhead;) For multiple showerheads serving one shower,the combined flow rate of all showerheads and/or bther shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets a Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallops per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute @ 60 psi Faucets- Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8.gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage/fly rate is equal to or lower than the figure shown,it is not required to be upgraded. 1 SB407 2015.doc revised 08/26/15 Arnold Hom 07/26/17 SHEET NO. DESCRIPTION SYMBOL ABBREV. DESCRIPTION ABBREV. SYMBOL DESCRIPTION ELECTRICAL CONN. LAYOUT 1 SCALE: NONE · · GAS CONNECTION SCHEMATIC DIAGRAM 2 SCALE: NONE DESCRIPTION UNIT TYPE (FLOOR PLAN) PIPE PENETRATION THRU (E) JOIST3 SCALE: NONE MARK MAKE MODEL COMMENTSVOLTAGEWT., LBS · LOCATION · · · · · · · · · · MODELMAKE MARK SEER VOLTAGE MCA COMMENTS · · · · · · · · · · · · · · · · A P A R T M E N T S G L E N B R O O K MANUFACTURER & MODEL NO.TAG SERVICE CFM @ 0.1 WG AMPERAGE CAPACITY VENT SIZE WATTAGE VOLTAGE OPER. WTG LBS COMMENTS · · · · · · · · · · · · AREA OF WORK · MATERIAL SERVICE · · · · · NEW DRYER DUCT IN (E) JOIST BAY4 SCALE: NONE Arnold Hom 07/26/17 07/26/17 B-2017-1179 Abby Ayende MANUFACTURER INFORMATION: PABCO® Gypsum a division of PABCO® building products, LLC PO Box 419074 Rancho Cordova, CA 95741 Technical Services: 866-282-9298 www.PABCOgypsum.com PABCO® Gypsum Specification PGS-002 ASTM specification C 1396 DESCRIPTION: The FLAME CURB® family of gypsum panel products is composed of a fire-resistant gypsum core, reinforced with glass fibers that provide increased strength and enhanced fire-resistant properties. The paper encasing the proprietary core is manufactured with 100% recycled paper and is folded around the long edges to reinforce in addition to protecting the core; the panel ends are cut square. The long panel edges are tapered, allowing a recessed joint area to be reinforced and concealed to create a monolithic surface suitable for decoration. FLAME CURB® Type X and 1/2” FLAME CURB® Type XXX meets and/or exceeds the requirements specified by ASTM under its wallboard standard ASTM C 1396 Type X. FLAME CURB® Super ’C’ is appropriate for applications requiring an extended fire resistance performance that exceeds the Type X “classified” core formulation in fire-resistive performance. This product was developed with the addition of mineral additives integrated into the product’s core to enhance the gypsum core’s performance during the exposure to fire. For fire and sound rated systems it is important to consult the appropriate fire resistance directory or test report for specific components and assembly that are acceptable for use in the specific system. Systems using FLAME CURB® Super ‘C’ qualify for fire ratings up to 4 hours in walls, 3 hours in ceilings and 4 hours for column protection. FLAME CURB® Type X and FLAME CURB® Super C are “classified” by Underwriters Laboratories in accordance with ASTM E 119 UL 263. continued on back Job name: Contractor: Date: PRIMARY USES: FLAME CURB® products are a non-structural gypsum panels intended for interior walls, ceilings, and partitions in residential and commercial applications which often require specific fire-resistant assemblies. FLAME CURB® Type C is appropriate for applications requiring an extended fire resistance performance that exceeds the Type X “classified” core formulation in fire-resistive construction. Additional applications include use as a roof underlayment per GA-276. This product is designed for direct mechanical attachment to metal or wood framing members. With the wallboard joints properly treated per GA-216 and GA-214, FLAME CURB® products will resist the passage of smoke. LIMITATIONS: • Intended for interior applications, and shall not be used where there will be direct exposure to water or continuous high humidity before, during, and after construction. • Non-load bearing • Avoid exposure to temperatures exceeding 125 degree F (52 degree C) for an extended period of time. • PABCO® FLAME CURB® is a non-structural panel, not to be used as a structural fastener base or to support wall or ceiling mounted objects. • All materials used in conjunction with the application of FLAME CURB® Type X, XXX or Super ‘C’ gypsum panels in Fire or Sound Rated systems shall be installed as specified in the applicable specific test report. APPLICATION: PABCO® Gypsum endorses the Gypsum Association’s publication GA-214, GA-216 (www. gypsum.org) and ASTM Standard Specification C840 (www.astm.org) as its application specification that provide detailed instructions on the standard application of wallboard panels and proper joint finishing procedures. For fire and sound rated systems it is important that you consult the appropriate fire resistance directory or test report for the complete assembly documentation and related information. These systems must be installed in strict compliance with the detailed fire test assembly description, including core types and other components such as studs, fastener spacing and fasteners type and installed as tested. To qualify for listed sound ratings, special caulking, insulation or clips are generally added to the systems as detailed in the test report. FIRE RESISTANT RATINGS: Fire Resistance Rated Designs are promulgated from tests performed at IAS* certified independent testing laboratories, and these designs include specific materials assembled in a precise configuration. When choosing construction details to achieve specific fire- resistance rated requirements, care must be taken to insure that each component of the specified assembly is the proper one specified in the referenced fire-resistance rated design, and assembled in accordance with the specific requirements of the assembly. *The International Accreditation Service — IAS — is a non-profit, public benefit corporation and a leading accreditation body in the United States. Internationally recognized, accreditation by IAS makes it easier to market products and services both inside and outside the United States. STORAGE & HANDLING: FLAME CURB® Type X, Type XXX, Type C, Super C what the job demands Arnold Hom 07/26/17 Store all PABCO® gypsum panels flat; do not store on edge as panels are heavy and may fall over causing injury or death. Store in an area that offers protection from adverse weather conditions, condensation, and other forms of moisture. Avoid job site conditions that expose gypsum board to water or moisture. Plastic shipping bags are temporary, and intended for protection during transit only, and must be removed promptly upon arrival. Store gypsum board under protected cover, off the ground with sufficient support to prevent sagging. Exercise proper care to avoid impact and/or scuffing of the glass faces, undue flexing, and damage to panel’s edges, corners, and ends. WARRANTIES & REMEDIES: Current warranty information for this product is available online at www.PABCOgypsum.com. LEGAL NOTICES: PABCO® Gypsum, the PABCO® logo, what the job demands™, and FLAME CURB® are trademarks or registered trademarks of Pacific Coast Building Products, Inc. and licensed to PABCO® Gypsum in the United States and other countries. Products described herein may not be available in all geographic markets. Consult your PABCO® Gypsum sales representative for information. Product features and Information subject to change without notice. Visit www.PABCOgypsum.com for product updates and current information. PRODUCT DATA, SIZES & TYPES: Product Thickness Width Length1 Edge Type Weight2 UL Core Type Type XXX 1/2" (12.7 mm) 48" (1219 mm) 8’ - 12' (2438 mm to 3658 mm) Tapered 1.9 lbs/ft 2 PG-3 Super C 1/2” (12.7 mm) 48” (1219 mm) 12’ (3658 mm) Tapered 2.0 lbs/ft 2 PG-C Type X 5/8” (15.8 mm) 48” (1219 mm) 8’ - 12’ (2438 mm to 3658 mm) Tapered, Round 2.2 lbs/ft 2 PG-11 Type X 5/8” (15.8 mm) 54” (1372 mm) 8’ - 12’ (2438 mm to 3658 mm) Tapered 2.2 lbs/ft2 PG-11 Type C 5/8” (15.8 mm) 48” (1219 mm) 12’ (3658 mm) Tapered 2.4 lbs/ft2 TYPE C PACKAGING: 2 pieces per bundle, face-to-face, and end labeled. 1Length availability may change; other lengths may be available on a special order basis. Consult with your local PABCO® representative 2Represents approximate weight for design and shipping purposes. A more exact weight may be available for your area; consult with your local PABCO® representative. APPLICABLE STANDARDS & TECHNICAL DATA: FLAME CURB® Thickness 1/2” 5/8” Manufacturing: ASTM C 1396 Installation: Gypsum Association GA-214, GA-216 – www.gypsum.org ASTM C 840 – www.astm.org Surface Burning Characteristics (ASTM E 84): Flame Spread 15; Smoke Developed 0 Combustibility (ASTM E 136): Non-Combustible Fire-Resistant Assemblies: Gypsum Association GA-600, Fire Design Manual Underwriters Laboratories, UL Fire Resistance Directory Permeance (perms; ng/Pa.s.m2) (ASTM E 96): > 1 > 1 Flexural Strength, Load lbf (N) (ASTM C 473): Test Method B Perpendicular to substrate edge 110 lbf (489 N) 107 lbf (476 N) Parallel to substrate edge 40 lbf (178 N) 46 lbf (205 N) Humidified deflection (ASTM C 473): 10/8” (32 mm) 5/8” (16 mm) Thermal resistance R value (ASTM C 518): 0.45 0.48 Composition: 100% recycled paper face, gypsum core Material Safety Data Sheet MSDS: MSDS available at www.PABCOgypsum.com, Technical Data Foil Application: Foil may be applied to the back of ASTM C 1396 gypsum wallboard for the purpose of complying with ASTM C 1396 paragraph 5.1. PABCO® Gypsum literature: “Construction Guide: Fire & Sound Rated Systems” Recycled Content: Refer to PABCO® Sustainable Materials Data Sheet for plant specific details. Federal Specification SS-L-30D Type III, Grade X. For Type C products should the Grade for the Federal Spec be ‘’R’. The federal specification for gypsum board, SS-L-30d was withdrawn in 1984. It is provided here for informational purposes only. NEED HELP WITH A PROJECT OR HAVE QUESTIONS ABOUT THIS PRODUCT? Contact the PABCO® Gypsum Technical Services Team at (866) 282-9298. ACHIEVE HIGH STC DESIGNS LIKE NEVER BEFORE WITH QUIETROCK! Visit www.QuietRock.com or call (800) 797-8159 to speak with a product specialist. FLAME CURB® Type X, Type XXX, Type C, Super C what the job demands Arnold Hom 07/26/17 · · · MECHANICAL FLOOR PLAN - DEMOLITION (UNIT TYPE "C") 1 SCALE: 1/4"=1'-0" MECHANICAL FLOOR PLAN - NEW (UNIT TYPE "C") 2 SCALE: 1/4"=1'-0" Arnold Hom 07/26/17 · · · · · · · · · · · · · · · · ELECTRICAL FLOOR PLAN - DEMOLITION (UNIT TYPE "C") 1 SCALE: 1/4"=1'-0" ELECTRICAL FLOOR PLAN - NEW (UNIT TYPE "C") 2 SCALE: 1/4"=1'-0" Arnold Hom 07/26/17