13090066CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 825 KIM ST
CONTRACTOR: NEW WORLD BUILDER
PERMIT NO: 13090066
OWNER'S NAME: HEMAMALINI SANKAR
1 196 BRANDYBOOD WAY
DATE ISSUED: 06/09/2014
OWNER'S PHONE: 4084167410
SAN JOSE, CA 95121
PHONE NO: (408) 472-3692
LICENSED CONTRACTOR'S DECLARATION
JOB DESCRIPTION: RESIDENTIAL E] COMMERCIAL
5
ADDITION OF 537 S.F. TO FRONT OF SFD, REMODEL (E)
License Class Lic. #' e7 O
KITCHEN & CREATE (N) DINING RM AREA. RE -ROOF (E)
V 6 (�
20 SQ'S TO MATCH ADDITION
Contractor t -)Date r?-Zv
I hereby of in that 1 am licensed under the provisions of Chapter 9 1
(commencing with Section 7000) of Division 3 of the Business & Professions
Code and that my license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
Sq. Ft Floor Area:
Valuation: $122000
performance of the work for which this permit is issued.
1 have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
APN Number: 35920004.00
Occupancy Type:
permit is issued.
APPLICANT CERTIFICATION
1 certify that 1 have read this application and state that the above information is
PERMIT EXPIRES IF WORK IS NOT STARTED
correct. I agree to comply with all city and county ordinances and state laws relating
WITHIN 180 DAYS OF ISSUANCE OR
to building construction, and hereby authorize representatives of this city to enterupon
�Ml'
the above mentioned property for inspection purposes. (We) agree to save
CLLED INSPECTION.
indemnify and keep harmless the City of Cupertino against liabilities, judgmen
costs, and expenses which may accrue against said City in consequence of the
granting of this permit. Additionally, the applicant understands and will comply
I Y.Date: v
with all non -point source regulations per the Cupertino Municipal Code, Section
9.18.
Signature dn%L Date C— 7, 1
RE -ROOFS:
All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
ElV OWNER -BUILDER DECLARATION
Signature of Applicant: Date:
I hereby affirm that I am exempt from the Contractor's License Law for one of
the following two reasons:
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
1, as owner of the property, or my employees with wages as their sole compensation,
will do the work, and the structure is not intended or offered for sale (Sec.7044,
Business & Professions Code)
I, as owner of the property, am exclusively contracting with licensed contractors to
HAZARDOUS MATERIALS DISCLOSURE
construct the project (Sec.7044, Business & Professions Code).
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
I hereby affirm under penalty of perjury one of the following three
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
declarations:
Health & Safety Code, Section 25532(a) should I store or handle hazardous
I have and will maintain a Certificate of Consent to self -insure for Worker's
material. Additionally, should I use equipment or devices which emit hazardous
Compensation, as provided for by Section 3700 of the Labor Code, for the
air contaminants as defined by the Bay Area Air Quality Management District I
performance of the work for which this permit is issued.
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
I have and will maintain Worker's Compensation Insurance, as provided for by
the Health & Safety Code, Sections 25505, 25533, and 25534.
Section 3700 of the Labor Code, for the performance of the work for which this
' / p
IiV J Date:
permit is issued.
Owner or authorized agent: C7
I certify that in the performance of the work for which this permit is issued, I shall
not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California. If, after making this certificate of exemption, 1
CONSTRUCTION LENDING AGENCY
become subject to the Worker's Compensation provisions of the Labor Code, I must
I hereby affirm that there is a construction lending agency for the performance of
forthwith comply with such provisions or this permit shall be deemed revoked.
work's for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
APPLICANT CERTIFICATION
Lender's Address
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
ARCHITECT'S DECLARATION
costs, and expenses which may accrue against said City in consequence of the
I understand my plans shall be used as public records.
granting of this permit. Additionally, the applicant understands and will comply
with all non -point source regulations per the Cupertino Municipal Code, Section
Licensed Professional
9.18.
Signature Date
CUPERTINO
CONSTRUCTION PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION O0�
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 41
(408) 777-3228 • FAX (408) 777-3333 • building a-cupertino.org
❑ NEW CONSTRUCTION © ADDITION ❑ ALTERATION / TI ❑ REVISION / DEFERRED ORIGINAL PERMIT #
PROJECT ADDRESS 825 KIM STREET 7
APN# 359-20-004
OWNER NAME
HEMAMALINI SANKAR
PHONE (408)416-7410
E-MAIL
171.LI11 —It
STREET ADDRESS 825 KIM STREET
CITY, STATE, ZIP CUPERTINO, CA
FAX N/A
CONTACT NAME Juancarlos Navarro
PHONE (408)205-9812 —7
E-MAIL jcnavarro@att.net
STREET ADDRESS 1734 Winston St
CITY, STATE, Z1PSan Jose, CA 95131
FAX (408)459-1619
❑ OWNER ❑ OWNER -BUILDER 11 OWNER AGENT 11 CONTRACTOR 11 CONTRACTOR AGENT W ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAME TBD
D
LICENSE NUMBER
LICENSE TYPE
BUS. LIC #
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
ARCHITECT/ENGINEER NAME Jose C. Fernadez
LICENSE NUMBER C76349
BUS. LIC #
COMPANY NAME
IF Consultingplans@gmail.com
E-MAIL
FAX
N/A
STREET ADDRESS 2915 Maclntyre Dr# 104
CITY, STATE, ZIP San Jose, CA 95136
PHONE(408)512-8400
DESCRIPTION OF WORK Interior remodel, addition. Remodel e) kitchen, add 537 s.f. to the front of the house to add
a new bedroom, one bathroom, and new living area, convert one bedroom into dining room and re -roof
entire house. (Bldg, Plumbing, Electrical and mechanical permits)
EXISTING USE
single fam
PROPOSED USE CONSTR.
No chane
TYPE
v
# STORIES
1
USE
TYPE
OCC.
SQ.FT.
VALUATION ($)
AREAEXIST
AREA
1, 603
NEW 1, 140
AREA
DEMO 165 Porc TOTAL
AREA NET AREA 2140
kitchen re
odel
$25 k
BATHROOM
REMODEL AREA
KITCHEN
REMODEL AREA ZZZ
OTHER
REMODEL AREA 2K too
Addition
537
$97 k
PORCH AREA
33
DECK AREA
0
TOTAL DECK/PORCH AREA
33
GARAGE AREA: DETACH
482 IM ATTACH
# DW'ELLING UNITS.
IS A SECOND UNIT ❑ YES
SECOND STORY ❑ YES
1
BEING ADDED? M NO
ADDITION? R) NO
PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF
IS THE BLDG AN ❑ YES
RECEIy TAL VALUATION -
PLANNING APPL # M NO PLANNING APPROVAL LETTER
EICHLER HOME? M NO
$122 k
owner or thorized a o ac a property owner's behalf. I have read this
By my signature below, 1 certify to each of the following: 1 am the plepresen
application and the information I have provided is correct. 1 have reaescripti of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building construction. 1 authoriz s of Cupertino to enter the above -identified property for inspection purposes.
Signature of Applicant/Agent: Juancarlos Navarro Date: September 11, 2013
SUPPLEMENTAL INFORM TIO E IRED
PLAN CHECK TYPE
ROUTING SLIP
0 OV R.TM-COUNTER
E3 BUILDING PLAN REVIEW
New SFD or Multifamily dwellings: Apply fo d olition pe it for
existing building(s). Demolition permit is required prior to issu ce of building
permit for new building.
❑ EXPRESS
❑ PLANNING PLAN REVIEW
Commercial Bldgs: Provide a completed Hazardous Materials Disclosure
C$ STANDARD
PUBLIC WORKS
form if any Hazardous Materials are being used as part of this project.
0 LARGE
13 FIRE DEPT
Copy of Planning Approval Letter or Meeting with Planning prior to
0 MAJOR
© SANITARY SEWER DISTRICT
submittal of Building Permit application.
© ENVIRONMENTAL HEALTH
BldgApp 2011.doc revised 06/21/11
CITY OF CUPERTINO
FEE ESTIMATOR - BUILDING DIVISION
OCCUPANCY TYPE:
825 KIM ST
DATE: 09/11/2013
REVIEWED BY: MELISSA
1WADDRESS:
APN: 359 20 004
BP#: ��9 GQ
'VALUATION: 1$122,000
*PERMIT TYPE: Building Permit
PLAN CHECK TYPE: Addition
PRIMARY SFD or Duplex
USE:
2nd Unit? Yes . No
OTC: O Yes (E) No I
PENTAMATION 1 R3SFDADD
PERMIT TYPE:
WORK
ADDITION OF 537 S.F. TO FRONT OF SFD REMODEL E KITCHEN & CREATE N DINING RM.
SCOPE
RE -ROOF (E) 20 SQ'S TO MATCH ADDITION
OCCUPANCY TYPE:
TYPE OF
CONSTR.
FLR AREA
s.f.
PC FEES
PC FEE ID
BP FEES
BP FEE ID
R-3 (Custom)
II-B'111-B,IV,V-B
537
$2,577.00
IR3PLNCK
$1,617.00
IR3INSP
PME Plan Check:
$0.00
100 s.f.
$418.00
Remodel, Other
IREMRESOTH
Permit Fee:
$1,617.00
Suppl. Insp. Fee -0 Reg. O OT
0,0
hrs
$0.00
2,000 s.f. Re -roof
$320.00 IREROOFRES
PME Unit Fee:
$0.00
PME Permit Fee:
$0.00
P. [Itl:ift"dti'(it)f? lt:.i:
TOTALS:
537
$2,577.00
$1,617.00
MECH, HOURLY O Yes Q No
PLUMB, HOURLY O Yes O ' No
ELEC, HOURLY -()Yes O No
MISC ITEMS
Plan Check Fee:
$2,577.00
222 1 s.£
$626.00
Remodel, Kitchen (<=300 sf)
IREMRESKIT
c'
�l. Tr:. A`•��
hrs
$0.00
PME Plan Check:
NOTE: This estimate does not include fees due to other Departments (i. e. Planning, Public Works, Fire, Sanitary Sewer District, School
District etc ). These fees are haled an the nreliminary information available and are only an estimate. Contact the Dent for addn'1 info.
FEE ITEMS (Fee Resolution 11-053 Eff 711113)
FEE
QTY/FEE
MISC ITEMS
Plan Check Fee:
$2,577.00
222 1 s.£
$626.00
Remodel, Kitchen (<=300 sf)
IREMRESKIT
Suppl. PC Fee: Q Reg. O OTT0.0
hrs
$0.00
PME Plan Check:
$0.00
100 s.f.
$418.00
Remodel, Other
IREMRESOTH
Permit Fee:
$1,617.00
Suppl. Insp. Fee -0 Reg. O OT
0,0
hrs
$0.00
2,000 s.f. Re -roof
$320.00 IREROOFRES
PME Unit Fee:
$0.00
PME Permit Fee:
$0.00
P. [Itl:ift"dti'(it)f? lt:.i:
E)
Work Without Permit? 0 Yes 0 No
$0.00
Advanced Planning Fee: IPLLONGR
$75.18
Select a Non -Residential
Building or Structure
O
O
4'' ,;rfn0.o i' ...
Strong, Motion Fee: IBSEISMICR
$12.20
Select an Administrative Item
Bldy, Stds Commission Fee: IBCBSC
$5.00
SUBTOTALS:
$4,286.38
$1,364.00
TOTAL FEE:
1 $5,650.38
Revised: 08/01/2013
CUPERTINO
CONTRACTOR / SUBCONTRACTOR LIST
Building Department
City Of Cupertino
10300 Torre Avenue
Cupertino, CA 95014-3255
Telephone: 408-777-3228
Fax: 408-777-3333
JOB ADDRESS: (R -2S K STfZC—GT— PERMIT # t 30 100 6 f -
OWNER'S NAME: HF—m,4 Ll N) —9kNKA- PHONE # 40& —
GENERAL CONTRACTOR: Ljo • d BUSINESS LICENSE #
ADDRESS: 119 (—� C7P4 Covc; UjCtX4 CITY/ZIPCODE: 5OAt-rV Com- I
*Our municipal code requires all bMinesses working in fte city to have a City of Cupertino business license.
NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE
GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO
BUSINESS LICENSE.
I am not using any subcontractors:
Signature
Please check applicable subcontractors and complete the following information:
Date
I/
SUBCONTRACTOR
BUSINESS NAME
BUSINESS LICENSE #
Cabinets & Millwork
Cement Finishing
Electrical
Excavation
Fencing
Flooring / Carpeting
Linoleum / Wood
Glass / Glazing
Heating
Insulation
Landscaping
Lathing
Masonry
Painting / Wallpaper
Paving
Plastering
Plumbing
Roofing
Septic Tank
Sheet Metal
Sheet Rock
Tile
r / Contractor Signature
qr
Date
CUPERTINO
CONTRACTOR / SUBCONTRACTOR LIST
Building Department
City Of Cupertino
10300 Torre Avenue
Cupertino, CA 95014-3255
Telephone: 408-777-3228
Fax: 408-777-3333
JOB ADDRESS:
PERMIT #
OWNER'S NAME: c(/
PHONE #
GENERAL CONTRACTOR:
BUSINESS LICENSE #
ADDRESS: � kl?A
CITY/ZIPCODE:
*Our municipal code requires all`fiusinesses worlAg in the city to have a City of Cupertino business license.
NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE
GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO
BUSINESS LICENSE.
I am not using any subcontractors.
Signature Date
Please check applicable subcontractors and complete the following information:
�I'v
Owner / Contractor Signature
� 12,0 lJr'
Date
SUBCONTRACTOR
BUSINESS NAME
BUSINESS LICENSE #
Cabinets & Millwork
Cement Finishing
Electrical
Excavation
Fencing
Flooring / Carpeting
Linoleum / Wood
Glass / Glazing
Heating
Insulation
Landscaping
Lathing
Masonry
Painting / Wallpaper
Paving
Plastering
Plumbing
Roofing
Septic Tank
Sheet Metal
Sheet Rock
Tile
�I'v
Owner / Contractor Signature
� 12,0 lJr'
Date
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Hema Sankar
825 Kim Street
Cupertino, CA 95014
Project Designer:
D -Cube Studio
1734 Winston Street
San Jose, California
408-205-9812
Report Prepared by:
Rick Rocklewitz
NRG Compliance, Inc
PO Box 3777
Santa Rosa, California 95402
707-237-6957
n
COMPLIAN7
Job Number:
08171301
Date:
8/17/2013
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 5.1 by EnergySoft Job Number: ID: 08171301 User Number: 5581
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Hema Sankar
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
8/17/2013
Project Address
825 Kim Street Cupertino
California Energy Climate Zone
CA Climate Zone 04
Total Cond. Floor Area
2,254
Addition
639
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ECJ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features see Part 2 of 5 Status
Floor Wood Framed w/Crawl Space
R-19 639 New
Wall Wood Framed
R-13 471 New
Door Opaque Door
None 40 New
Roof Wood Framed Attic
R-30 639 New
Floor Wood Framed w/Crawl Space
None 1,615 Existing
Roof Wood Framed Attic
R-11 1,611 Existing
Wall Wood Framed
None 1,080 Existing
Door Opaque Door
None 18 Existing
FENESTRATION U-
Orientation Area fo Factor
Exterior
SHGC Overhang Sidefins Shades Status
Front (E) 40.0 0.400
0.40 none none Bug Screen New
Right (N) 3.0 0.400
0.40 none none Bug Screen New
Skylight 4.0 0.550
0.67 none none None Existing
Left (S) 55.0 0.550
0.67 none none Bug Screen Existing
Rear (W) 101.0 0.550
0.67 none none Bug Screen Existing
Right (N) 76.0 0.550
0.67 none none Bug Screen Existing
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 78% AFUE Split Air Conditioner 11.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC System Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnergyPro 5,1 by Ener Soft User Number: 5581 RunCode: 2013-08-17T13:57:45 ID: 08171301
Pae 3 of 10
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Hema Sankar
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
$/17/2013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
Ener Pro 5.1 by EnerqVSoft User Number.- 5581 RunCode: 2013-08-17T13:57:45 /D: 08171301 Page 4 of 10
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type mSingle Family ❑ Addition Alone
Date
Hema Sankar
❑ Multi Family m Existing+ Addition/Alteration
8/17/2013
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 57.91 52.36 5.55
Space Cooling 33.75 32.85 0.90
Fans 13.96 13.22 0.74
Domestic Hot Water 18.16 18.16 0.00
Pumps 0.00 0.00 0.00
Totals 123.77 116.58 7.19
Percent Better Than Standard: 5.8
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 402 40
Fuel Available at Site: Natural Gas (S) 540 55
Raised Floor Area: 2,254 (W) 402 101
Slab on Grade Area: 0 (N) 540 79
Average Ceiling Height: 8.0 Roof 2,254 4
Fenestration Average U -Factor: 0.53 TOTAL: 279
Average SHGC: 0.63 Fenestration/CFA Ratio: 12.4%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author x
Company NRG Compliance, Inc
8/17/2013
Address PO Box 3777 Name Rick Rock/ewitz
City!State/Zip Santa Rosa, California 95402 Phone 707-237-6957 Si Rd Date
The individual with overall design responsibility hereby certifies that the proposed b ilding design represented in this set
of construction documents is consistent with the other compliance forms and work heets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes t at compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and b 'Iding envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) i
Company D -Cube Studio
Address 1734 Winston Street Name D -Cube Studio
City/State/Zip San Jose, California Phone 408-205-9812 ig d License Date
Ener Pro 5.1 by Ene Soft User Number. 5581 RunCode: 2013-08-17713:57:45 ID: 08171301 Pa e 5 of 10
CERTIFICATE OF COMPLIANCE:
Residential
(Part 4 of 5) CF -1 R
Project Name
Hema Sankar
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration7D7ate
013
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Floor
639
0.037 R-19
0
180 New 4.4.1-A4
First Floor
Wall
162
0.102 R-13
90
90 New 4.3.1-A3
First Floor
Door
40
0.500 None
90
90 New 4.5.1-A4
First Floor
Wall
156
0.102 R-13
180
90 New 4.3.1-A3
First Floor
Wall
153
0.102 R-13
0
90 New 4.3.1-A3
First Floor
Roof
639
0.031 R-30
90
18 New 4.2.1-A20
First Floor
Floor
1,615
0.097 None
0
180 Existing 4.4.1-A1
First Floor
Roof
1,611
0.079 R-11
90
18 Existing 4.2.1-A2
First Floor
Wall
142
0.356 None
90
90 Existing 4.3.1-A1
First Floor
Door
18
0.500 None
90
90 Existing 4.5.1-A4
First Floor
Wall
329
0.356 None
180
90 Existing 4.3.1-A1
First Floor
Wall
301
0.356 None
270
90 Existing 4.3.1-A1
First Floor
Wall
308
0.356 None
0
90 Existing 4.3.1-A1
First Floor
Wall
242
0.356 None
90
90 Remove 4.3.1-A1
First Floor
FENESTRATION SURFACE DETAILS
ID
Type
Area Ll -Factor' SHGC
Azm Status
Glazing Type
Location/Comments
1
Window
40.0 0.400 NFRC 0.40 NFRC
90 New
Dual Vinyl LowE
First Floor
2
Window
3.0 0.400 NFRC 0.40 NFRC
0 New
Dual Vinyl LowE
First Floor
3
Skylight
4.0 0.550 Default 0.67 Default
90 Existing
Double Non Metal Clear
First Floor
4
Window
55.0 0.550 Default 0.67 Default
180 Existing
Double Non Metal Clear
First Floor
5
Window
101.0 0.550 Default 0.67 Default
2701 Existing
Double Non Metal Clear
First Floor
6
Window
76.0 0.550 Default 0.67 Default
0 Existing
Double Non Metal Clear
First Floor
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC Hat Wd
Ove hang Left Fin Right Fin
Len Hat I LExt RExt Dist Len H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
None
1.00
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
EnergyPro
5.1 by Ener Soft User Number: 5581 RunCode: 2013-08-17713:57:45 ID: 08171301
Page 6 of 10
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R
Project Name
Hema Sankar
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
8/17/2013
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existina I Altered Removed Volume Year Built
HVAC S stem Addition
639
5,112
Existing
1,615
12,920 1959
Totals 6391 1,6151 0 01
1
HVAC SYSTEMS
System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC System 1 Central Furnace
78% AFUE Split Air Conditioner 11.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Coolinq Duct Location R -Value
Ducts
Tested? Status
HVAC System Ducted
Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
No Pipe Insulation
40,000
50
0.58
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
0
i�
-0 n
a
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty.
HP
Plenum
Outside
Buried
EnergyPro 5.1 by EnergySoft User Number: 5581
RunCode: 2013-08-17713:57:45 0: 08171301
Pae 7 of 10
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Hema Sankar
Date
1811712013
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(i)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number: 5581 RunCode: 2013-08-17713:57:45 ID: 08171301 Page 8 of 10
.1 tr`
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Hema Sankar
8/17/2013
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tae is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ftz or 100 watts for dwelling units larger than 2,500 ftz may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number. 5581 RunCode: 2013-08-17T13:57:45 /D: 08171301 Page 9 of 10
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Hema Sankar
8/17/2013
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (FMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number: 5581 RunCode: 2013-08-17713:57:45 ID: 08171301 Page 10 of 10
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Hema Sankar
825 Kim Street
Cupertino, CA 95014
Project Designer:
D -Cube Studio
1734 Winston Street
San Jose, California
408-205-9812
Report Prepared by:
Rick Rocklewitz
NRG Compliance, Inc
PO Box 3777
Santa Rosa, California 95402
707-237-6957
a :i COMPLIANCE,
Job Number:
08171301
Date:
8/17/2013
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
Number: 5581
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
EnergyPro 5.1 by EnergySoft Job Number: ID: 08171301 User Number: 5581
2
3
8
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Hema Sankar
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
8/17/2013
Project Address
825 Kim Street Cupertino
California Energy Climate Zone
CA Climate Zone 04
Total Cond. Floor. Area
2,254
Addition
639
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features see Part 2 of 5 Status
Floor Wood Framed w/Crawl Space
R-19 639 New
Wall Wood Framed
R-13 471 New
Door Opaque Door
None 40 New
Roof Wood Framed Attic
R-30 639 New
Floor Wood Framed w/Crawl Space
None 1,615 Existing
Roof Wood Framed Attic
R-11 1,611 Existing
Wall Wood Framed
None 1,080 Existing
Door Opaque Door
None 18 Existing
FENESTRATION U-
Orientation Area(ft) Factor
Exterior
SHGC Overhang Sidefins Shades Status
Front (E) 40.0 0.400
0.40 none none Bug Screen New
Right (N) 3.0 0.400
0.40 none none Bug Screen New
Skylight 4.0 0.550
0.67 none none None Existing
Left (S) 55.0 0.550
0.67 none none Bug Screen Existing
Rear (W) 101.0 0.550
0.67 none none Bug Screen Existing
Right (N) 76.0 0.550
0.67 none none Bug Screen Existing
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 78% AFUE Split Air Conditioner 11.0 SEER Setback Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC System Ducted
Ducted Attic, Ceiling Ins, vented 4.2 Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnergyPro 5.1 by EnergySoft User Number. 5581 Run Code: 2013-08-17T13:57:45 ID: 08171301
Page 3 of 10
PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF -1 R
Project Name
Hema Sankar
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
1811712013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
Ener Pro 5.1 by Ener Soft User Number. 5581 RunCode: 2013-08.17713:57:45 0:08171301 Page 4 of 10
PERFORMANCE CERTIFICATE: Residential Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Hema Sankar
1 ❑ Multi Family m Existing+ Addition/Alteration
8/17/2013
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kgtu/ft2- r
Space Heating 57.91 52.36 5.55
Space Cooling 33.75 32.85 0.90
Fans 13.96 13.22 0.74
Domestic Hot Water 18.16 18.16 0.00
Pumps 0.00 0.00 0.00
Totals 123.77 116.58 7.19
Percent Better Than Standard: 5.8
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 402 40
Fuel Available at Site: Natural Gas (S) 540 55
Raised Floor Area: 2,254 (W) 402 101
Slab on Grade Area: 0 (N) 540 79
Average Ceiling Height: 8.0 Roof 2,254 4
Fenestration Average U -Factor: 0.53 TOTAL: 279
Average SHGC: 0.63 Fenestration/CFA Ratio: 12.4%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company NRG Compliance, Inc
8/17/2013
Address PO Box 3777 Name Rick Rocklewitz�
City/State/ZipCity/State/Zip Santa Rosa, California 95402 Phone 707-237-6957 Signed Date
The individual with overall design responsibility hereby certifies that the proposed ' ing design represented in this set
of construction documents is consistent with the other compliance forms and wor she ts, with the specifications, and
with any other calculations submitted with this permit application, and recognize that 1compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and ildi�g envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company D -Cube Studio IL;_
Address 1734 Winston Street Name D -Cube Studio j.
City/State/Zip San Jose, California Phone 408-205-9812 qned License # Date
Ener Pro 5.1 by EnerqySoft User Number: 5581 Run Code: 2013-08-17713:57:45 /D: 081713AI Pae 5 of 10
CERTIFICATE OF COMPLIANCE:
Residential
Part 4 of 5) CF -1 R
Project Name
Hema Sankar
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
8/17/2013
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Floor
639
0.037 R-19
0
180 New 4.4.1-A4
First Floor
Wall
162
0.102 R-13
90
90 New 4.3.1-A3
First Floor
Door
40
0.500 None
90
90 New 4.5.1-A4
First Floor
Wall
156
0.102 R-13
180
90 New 4.3.1-A3
First Floor
Wall
153
0.102 R-13
0
90 New 4.3.1-A3
First Floor
Roof
639
0.031 R-30
90
18 New 4.2.1-A20
First Floor
Floor
1,615
0.097 None
0
180 Existing 4.4.1-A1
First Floor
Roof
1,611
0.079 R-11
90
18 Existing 4.2.1-A2
First Floor
Wall
142
0.356 None
90
90 Existing 4.3.1-A1
First Floor
Door
18
0.500 None
90
90 Existing 4.5.1-A4
First Floor
Wall
329
0.356 None
180
90 Existing 4.3.1-A1
First Floor
Wall
301
0.356 None
270
90 Existing 4.3.1-A1
First Floor
Wall
308
0.356 None
0
90 Existing 4.3.1 -Ai
First Floor
Wall
242
0.356 None
90
90 Remove 4.3.1 Al
First Floor
FENESTRATION SURFACE DETAILS
ID
Type I
Area U -Factor SHGC
Azm Status
Glazing Type
Location/Comments
1
Window
40.0 0.400 NFRC 0.40 NFRC
90 New
Dual Vinyl LowE
First Floor
2
Window
3.0 0.400 NFRC 0.40 NFRC
0 New
Dual Vinyl LowE
First Floor
3
Sk li ht
4.0 0.550 Default 0.67 Default
90 Existing
Double Non Metal Clear
First Floor
4Window
55.0 0.550 Default 0.67 Default
180 Existing
Double Non Metal Clear
First Floor
5
Window
101.0 0.550 Default 0.67 Default
2701 Existing
Double Non Metal Clear
First Floor
6
Window
76.0 0.550 Default 0.67 Default
0 Existing
Double Non Metal Clear
First Floor
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-8 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC Hot Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len Hot Dist Len Hot
1
Bug Screen
0.76
2
Bug Screen
0.76
3
None
1.00
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
EnergyPro
5.1 by EnergySoft User Number.- 5581 RunCode: 2013-08-17T13:57:45 /D: 08171301
Page 6 of 10
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R
Project Name
Hema Sankar
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family 0 Existing+ Addition/Alteration
Date
8117/2013
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area fe
New Existing_Altered I Removed Volume Year Built
HVAC System Addition
639
5,112
Existing
1,615
12,920 1959
Totals 639 1,615 0 0
HVAC SYSTEMS
System Name Qt . Heatin T pe
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC System 1 Central Furnace
78% AFUE Split Air Conditioner 11.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Cooling
Duct
Duct Location R -Value
Ducts
Tested? Status
HVAC System Ducted Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated Tank
Input Cap.
Btuh al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
No Pipe Insulation
40,000 50
0.58
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
ft
0
i�
CQ
Q —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty.
HP
Plenum Outside
Buried
Ener Pro 5.1 by EnergySoft User Number: 5581
RunCode: 2013-08-17T13:57:45 ID: 08171301
Page 7 of 10
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Hema Sankar
Date
8/17/2013
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no areater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-8 and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance and wind.
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number: 5581 RunCode: 2013-08-17713:57:45 0: 08171301 Page 8 of 10
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Hema Sankar
1811712013
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire as specified by § 150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number: 5581 RunCode: 2013-08-17713:57:45 0:08171301 Page 9 of 10
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Hema Sankar
8/17/2013
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number: 5581 RunCode: 2013-08-17T13:57:45 0:08171301 Page 10 of 10