B-2017-0261CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-0261
10148 S TANTAU AVE CUPERTINO, CA 95014-3542 (375 07 037) OWNER/BUILDER
10148 S TANTAU AVE
CUPERTINO, CA 95014
OWNER'S NAME: LEDAIN JOELAND WANG JEAN TRUSTEE
OWNER'S PHONE: 408-504-6809
LICENSED CON T TOR' D f I AR ATION
License Class Lic. #
Contractor OWNER/BUILDER Date
I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing
with Section 7000) of Division 3 of the Business & Professions Code and that my
license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
1. I have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
z. I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above
information is correct. I agree to comply with all city and county ordinances
and state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above mentioned property for
inspection purposes. (We) agree to save indemnify and keep harmless the
City of Cupertino against liabilities, judgments, costs, and expenses which
may accrue against said City in consequence of the granting of this permit.
Additionally, the applicant understands and will comply with all non -point
source regulations per the Cupertino Municipal Code, Section 9.18.
Signature Date 02/14/2017
I hereby affirm that I am exempt from the Contractor's License Law for one of the
following two reasons:
1. I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
/sale (Sec.7044, Business & Professions Code)
,, z. I, as owner of the property, am exclusively contracting with licensed
L-"' contractors to construct the project (Sec.7044, Business & Professions Code).
hereby affirm under penalty of perjury one of the following three declarations:
1. I have and will maintain a Certificate of Consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
2. I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the
Worker's Compensation laws of California. If, after making this certificate of
exemption, I become subject to the Worker's Compensation provisions of the
Labor Code, I must forthwith comply with such provisions or this permit shall
be deemed revoked.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws
relating to building construction, and hereby authorize representatives of this city
to enter upon the above mentioned property for inspection purposes. (We) agree
to save indemnify and keep harmless the City of Cupertino against liabilities,
judgments, costs, and expenses which may accrue against said City in
consequence of the granting of this permit. Additionally, the applicant understands
and will comply with all non -point source regulations per the Cupertino Municipal
Code, Section 9.18.
Signature Date 02/14/2017
DATE ISSUED: 02/14/2017
PHONE NO: OWNER/BUILDER
BUILDING PERMIT INFO:
BLDG —ELECT X PLUMB
MECH X RESIDENTIAL _ COMMERCIAL
JOB DESCRIPTION:
50 GAL WATER HEATER - GARAGE
Sq. Ft Floor Area: Valuation: $1600.00
APN Number: Occupancy Type:
375 07 037
PERMIT EXPIRES IF WORK IS NOT STARTED
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
180 DAYS FROM LAST CALLED INSPECTION.
by:
RE -ROOFS:
All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
Signature ofApplicant:
Date: 02/14/2017
ALL ROOF COVERINGS TO BE CLASS "A"
HAZARDOUS MATERIALS DISCLOSURE
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
Health & Safety Code, Section 25532(a) should I store or handle hazardous
material. Additionally, should I use equipment or devices which emit hazardous
air contaminants as defined by the Bay Area Air Quality Management District I
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
the Health & Safety Code, Sections 25505, 25533, and 25534.
Owner or authorized agent: ! '
Date: 02/14/2017
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance
of work's for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
Lender's Address
ARCHITECT'S DECLARATION
understand my plans shall be used as public records.
Licensed
Professional
CUPERTINO
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • buildinana cupertino.org
m I S Cm"k
0''Zo 1 I- 0Z
t� b
®PLUMBING I 1,4ECHANICAL 7 -RT F.C'TRTrAT. 7TKATer'FTTerTPnrTc
PROJECT ADDRESS
A PNr r :3
—0
ONVNER NAME
PHONE �i E-MLAIL
l5
6-! H Vct AA1 C_ 1 L
STREETADDRESS r ^ f (
L 0 (
"r teaA CITY, STAT P `
'
F -D' FAX
®
��Ys/
s
CONTACT NAME
PHONE E-MAIL
STREETADDRESS 4A
V
CITY, STATE, ZIP
FAX
❑
OWNER OWNER-BbIDER
❑ OW-I\ERAGENTT ❑ CONTRACTOR ❑CONTRACTORAGEN'T ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT
CONTRACTOR,
N-1
Y,6—t Vl.
LICENSE NUMBER. LICENSE TYPE
wt, Va LG i
BUS. LIC =o
COMPANY NAME
E-MAu
FAX
STREETADDRESS
��
RIAr'effA'u
CITY, STATE, ZIP g
PHONE
�� f
OL,
40es
ARCHITECT/ENGINEER NAME
LICENSE NUMBER
BUS. LIC
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
USE GF ❑ SFD or DUPLEX
❑ MULTI -FAMILY I PROSECT IN WII.DI-AND ❑ YES PROTECT IN ❑ YES
LS THE BLDG AN ❑ YES
BUILDING: ❑ COM IdERC_LA1.
I TIRB.AN INTERFACEAR.EA ❑ NO FLOOD ZONE ❑ NO
EICHLER HOME? - ❑ NO
DESCRIPTION OF WORK
.n
TOTALv.ALUanoN:_
�.-
� G�,...;.,...:,$�.<:<<:�':<':=:>;:>.�:::::::.�,t.,
.:::,�:><.�_::>_<'::'.,_:;;-�>
By ray signature below, I certify to each of the following: I am the property owner or authorized agent to act on e pr
owner's beha ave read this
application and the information I have provided is correct. I have read the Description of'Work and verify it is acct
Imply with all applicable local
ordinances and state lawsrelating
to building construction. I authorize representatives of Cupertino to enter the above. -identified property for inspection purposes.
Date:
Signature of Applicant/A gent:
SUPP MENTAL INTFORMATION REQUIRED
oFr``.
-` ,:E
EXPRE$5. j;- r.:=.`34::'I: `L �i • r:=.>::
- -
U.
c-
er<r
A1EPR1flscApp_2011.doc T-evised 06121/11
am
CUPERTINO
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE - CUPERTINO, CA 95014-3255
(408) 777-3228 - FAX (408) 777-3333 - building cDcupertino.org
Dear Property Owner(s):
An application for a building permit has been submitted in your name listing yourself as the builder of the property
improvements specified at:
SITE ADDRESS 119 1e �y ,5; ��
F �j
APN -3 7 5- — /, 3 p �) �
V V
3 - 2-o I'4 —d Z,G
OWNER NAME —
OWYR ADDRE S
DESCRIPTION OF WORK:
We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of
your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We
will not issue a building permit until you have read, initialed your understanding of each provision, signed, and
returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless
you, the property owner, obtain the prior approval of the permitting authority.
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION
(DIRECTIONS: Please read and initial each statement below to signify you understand or verify this information.)
V
I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner-
' building permit that erroneously implies that the property owner is providing his or her own labor and material
personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by
i an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not
provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my
insurance coverage for injuries to workers on my property.
I understand building permits are not required to be signed by property owners unless they are responsible for
construction and are not hiring a licensed Contractor to assume this responsibility.
I understand as an "Owner -Builder' I am the responsible party of record on the permit. I understand that I may
ro ect myself from" potential financial risk by hiring a licensed Contractor and having the permit filed in his or her
name instead of my own.
- I understand Contractors are required by law to be licensed and bonded in California and to list their license
umbers on permits and contracts.
�I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the
talalue of my construction is at least five hundred dollars ($500), including labor and materials, I may be
considered an "employer' under state and federal law.
I understand if I am considered an "employer' under state and federal law, I must register with the state and
i
deragovernment, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to
unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject
me to serious financial risk.
7- I understand under California Contractors' State License Law, an Owner -Builder who builds single-family
esidential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by
licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work
is performed under contract with a licensed general building Contractor.
J8. I understand as -an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for
any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction
defects in the workmanship or materials.
OwnerBuilderForm 2010.doc revised 04114110
f; sk4 I understand I may obtain more information regarding my obligations as an "employe" from the? Internal
'Re—venue Service, the United States Small Business Administration, the California Department of Benefit Payments,
and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State
License Board (CSLB) at 1-800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed
contractors.
�0. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I
am the party legally and financially responsible for proposed construction activity at the site address listed above.
I agree that, as the party legally and financially responsible for this proposed construction activity, 1 will abide
012.
plicable laws and requirements that govern Owner -Builders as well as employers.
1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the
ion I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If
you contract with someone who does not have a license, the Contractors' State License Board may be unable to
assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed
Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or
employee of that individual or firm is injured while working on your property, you may be held liable for damages. If
you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not
those Contractors are properly licensed and the status of their workers' compensation insurance coverage.
CONSTRUCTION LENDING AGENCY
(DIRECTIONS: Please complete the following construction lending agency information.)
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued
(Sec 3097 Civ.)
Lender Name: Lender Address:
Before a building permit can be issued, this form must be completed and signed by the property owner and
returned to the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license,
form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued
to verify the property owner's signaWre.
Property Owner's Signature: -ti — L- J Date. ,i/l t-(-�Q ( j
---------------------------------------------------------------------------------------------------------------------------------------------
(NOTE. The following Authorization Form is required to be completed by the property owner only when designating an
agent of the property owner to apply for a construction permit for the Owner -Builder).
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby
authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an
Owner -Builder Permit for my project.
Scope of Construction Project (or Description of Work):
Project Location or Address:
Name of Authorized Agent:
Address of Authorized Agent:
Tel No
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the
above information and certify its accuracy. Note: A copy of the property owner's driver's license, form notarization, or other
verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's
signature.
Property Owner's Signature:
Date:
OwnerBuilderFOrn1 2010.doc revised 04114110
This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for
compliance with -2016 CRC Section R314, 8315, 2016 CBC Sections 420.6 and 907.2.11.2 where no interior access
for inspections are required.
GENERAL INFORMATION
Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon
Monoxide, alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds
$1000.00, CRC Section 8314, R315, and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or
Carbon Monoxide Alarms be installed.in the following locations:
F-- AREA
SMOKE ALARM
CO ALARM��
Outside of each separate sleeping area in the immediate vicinity of the
bedroom(s) — (Smoke alarms shall not be located within 3 feet of bathroom door)
X
X
On every level of a dwelling unit includin basements and habitable attics
X
X
Within each sleeping room.
_ X
_J
Carbon Monoxide alarms are not required in dwellings wlnich do not contain fuel -burning appliances and that
do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with
CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal.
Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated.
In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do
not result ii the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl
space. Refer to CRC Section 8314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for
alarms which must be connected to the building wiring.
As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been
installed in accordance with the.manufacturer's instructions and i1 compliance with the California Building
and California Residential Codes. The alarms specified below have been tested and are operational, as of the
date signed below.
fc 2�i�Address:uvl
Specify Number of Alarms: # Smoke Alarms -T_771 # Carbon Monoxide Detectors:
I have read and agree to comply with the terms and conditions of this statement
Owner (or Owner Agent's) Name:
LGf' �V
Si nature ...... ..........-�- L .�✓....... ... F............................................. ......... D2..
Contractor Name:
Signature.................................................................. Lic.# ......................................Date:..................
Smoke and COfonn.doc remised 0111011017
CUPERT1Nti
Owner Name
WATER -CONSERVING PLUMBING FIXTURES
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 -.FAX (408) 777-3333 • building(a)cupertino.org
Im
Addressf � �—c�L43;UAt CiA 1 ?'-
1. Is your real property a registered historical site?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
gNo Go to Question 2.
2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its
plumbing, installation of water -conserving plumbing fixtures is not technically feasible?
❑ Yes',, Civil Code Sections 1101.1 through 1101.8 do not apply.
❑ The licensed plumber's certification has been provided to the Building Division.
Skip the rest of the form and sign bottom of form.
[� No Go to Question 3.
3. Is water service permanently disconnected for your building?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
7 I No Go to Question 4.
4. Is your real property built and available for use or occupancy on or before January 1, 1994?
No My real property is built and available for use or occupancy after January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
' ❑ Yes My real property is built and available for use or occupancy on or before January 1, 1994.
Civil Code Sections 1101,1 through 1101.8 apply. Check one of the three following statements and sign
bottom of form..
5. Please check ONE of the following:
❑ My property is a single-family residential real property. See Civil Code Section 1101.4.
On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures
to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-
compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether
property undergoes alterations or improvements).
❑ My properly is a multifamily residential real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water -
conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or
improvements).
❑ My property is a commercial real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving
plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements).
I, as the owner or owner's agent of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be
replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 110 1. 1
through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's
installation requirements, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the
table on the following page. 117 n 1
Owner or Owner Agent's Signature: )/% Date:- - --i � - r /
Upon completing and signing this Certificate, ase return it to the Bur ding Division in order to final your building permit.
SB4072015.doc revised 08126115
1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded.
SB407 2015. doc revised 08/26/15
Non -Compliant
Water -Conserving Plumbing Fixture
PlumbingFixture
(Fixture Complying with Current Code Applicable to New Construction)
Fixture Type
Maximum Water Usage/Flow Rate
2013 CPC Ch. 4
2013 CPC Ch. 4
2013 CPC Ch. 4
Water Usage
/Flow Rate
2013 CALGreen Div. 4.3
2013 CALGreen Div, 4.3
2013 CALGreen Div. 5.3
Single -Family
Multi -Family
Commercial
Residential
Residential
Water Closets
Exceed 1.6
Single flush toilets: 1.28 gallons/flush
(Toilets)
Gallons/flush
Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite,
average flush volume of two reduced flushes and one full flush
Urinals
Exceed 1.0
Gallons/flush
0.5 gallons/flush
Showerheads
Exceed 2.5
2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of
gallons per minute
U.S. EPA WaterSense Specification for Showerheads
(A hand-held shower is considered a showerhead.)
For multiple showerheads serving one shower, the combined flow rate of all
showerheads and/or other shower outlets controlled by a single valve shall not
exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to
allow only one shower outlet to be in operation at a time.
Faucets —
Exceed 2.2 gallons
Maximum 1.5 gallons per
Within units:
0.5 gallons per minute @ 60
Lavatory
per minute
minute @ 60 psi; minimum
Maximum 1.5 gallons
psi
Faucets
0.8 gallons per minute @
per minute @ 60 psi;
20 psi
minimum 0.8 gallons
per minute @ 20 psi
In common and public
use areas: 0.5 gallons
per minute @ 60 psi
1.8 gallons per minute
60 psi
Faucets —
Exceed 2.2 gallons
1.8 gallons per minute @
1.8 gallons per minute
1.8 gallons per minute @ 60
Kitchen
per minute
60 psi
@ 60 psi
psi
Faucets
May temporarily increase
May temporarily
up to 2.2 gallons per
increase up to 2.2
minute @ 60 psi, and must
gallons per minute @
default to maximum
60 psi, and must
1.8 gallons per minute @
default to maximum
60 psi
1.8 gallons per minute
Where faucets meeting
@ 60 psi
the above are unavailable,
Where faucets meeting
aerators or other means
the above are
may be used to achieve
unavailable, aerators or
reduction.
other means may be
used to achieve
reduction.
1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded.
SB407 2015. doc revised 08/26/15