Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
14120065
I CITY OF CUPERTINO BUILDING PERMIT I 1 BUILDING ADDRESS: 20630 STEVENS CREEK BLVD I CONSTR CT ON GENERAL I PERMIT NO: 14120065 CAL WEST I OWNER'S NAME: BYER PROPERTIES LP 1 11745 BENNETTA CT I DATE ISSUED: 02/05/2015 1 OWNER'S PHONE: 4087788088 ❑ LICENSED CONTRACTOR'S DECLARATION License Class J��,5 Lic. # Contractor Date 7�-:2 -10- �l [S I hereby affirm that am licensed un er the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: 1 have and will maintain a certificate of consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this bermit is issued. APPLICANT CERTIFICATION ertify that 1 have read this application and state that the above information is rrect. I agree to comply with all city and county ordinances and state laws relating building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. /_11 1 Date4�2V, l ❑ OWNE"UILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). 1 hereby affirm under penalty of perjury one of the following three declarations: I have and will maintain a Certificate of Consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 1 certify that in the performance of the work for which this permit is issued, l shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Date GILROY, CA 95020 1 PHONE NO: (408) 355 -0951 JOB DESCRIPTION: RESIDENTIAL [] COMMERCIAL ❑ ETERNAL BEAUTY SKIN & LASER T.I. TO CREATE (N) OCCUPANCY FOR SALON WITH RECONFIGURATION OF INTERIOR AND M.E.P.'S (4,040 S.F.) REVISION # SE ELECTRICAL PLANS- ISSD OTC 3/10/15 Sq. Ft Floor Area: I Valuation: $70000 APN Number: 35908020.20630 1 Occupancy Type: PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by:, � �G Dater ��% '1�5 RE- ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should 1 use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505,2 ,-qn 5534. Owner or authorized agent: Dater CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional CUPERTINO GENERAL PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT' BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 (408) 777 -3228 • FAX (408) 777 -3333 • buildin cu ertinao T vl ..■ M ■ s.■ . PLUMBING ❑MECHANICAL ELECTRICAL ❑MISCELLANEOUS PROJECT ADDRESS APN # w " -- C 35q 0& C)2,a •ov. OWNERNAME E -MAIL —Y 'G �E',ti��Y' '�Zlo• -7. STREET ADDRESS Y „ CITY, STATE, ZIP FAX CONTACT NAME PHONE E -MAIL STREET ADDRESS CITY, STATE, ZIP FAX ❑ OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT CONTRACTOR ❑ CONTRACTOR AGENT 11 ARCHITECT ❑ ENGINEER 11 DEVELOPER El TENANT N CONTRACTOR NAME {w Y LICENSE UMBER 741,y LICENSE TYPE BUS. LIC # COMPANY NAME K � � / rt f e� E -MAIL G �1 f c I9 G� 'I v serif ztJ l . HI ( FAX V STREET ADDRESS �f CITY, ST' E, ZIP P NE 6 Su.� � fa K 4 Or _ 1� G_t�, .5 o ZU y 7 -Y-% y9 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E -MAIL FAX STREET ADDRESS CITY, STATE„ "ZIP PHONE USE OF ❑ SFD or DUPLEX ❑ MULTI- FAMILY PROJECT IN WH-DLAND ❑ YES PROJECT IN ❑ YES IS THE BLDG AN ❑ YES BUILDING: ❑ COMMERCIAL URBAN INTERFACE AREA ❑ NO FLOOD ZONE ❑ NO EICHLER HOME? ❑ NO DESCRIPTION OF WORK �(Z-e. ' -> i'. 1,2evt ie de-'c I'lien �? J,. TOTAL VALUATION: S r'I / RECEIVED BY: By my signature below, I certify to each o ollowing: I am the pro pe owner or authorized agent to act on the property owner's behalf. I have read this application and the infonnation I hav o � ed is correct. I hav e Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relatin ui mg cons do t ze re resentatives of Cupertino to enter the above -iden fled p perty for inspection purposes. Signature of Applicant/Agent: Date: SUPPLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY',' ❑ -OVER- THE COUNTER X❑. EXPEtESS I_I LARGE F ©i ALUOR MEPMiscApp_201 1. doc revised 06121111 CITY OF CUPERTINO BUILDING PERMIT I BUILDING ADDRESS: 20630 STEVENS CREEK BLVD I CONTRACT' TDDr -40.BE PERMIT NO: 14120065 OWNER'S NAME: BYER PROPERTIES LP I ('hV1 In I DATE ISSUED: 02/05/2015 1 OWNER'S PHONE: 4087788088 LICENSED CONTRACTOR'S DECLARATION License Class iN A� EZ Lic. # Z`Z Z % 5 Contractor Date I hereby affirm that I am licensed under the provisions of C apter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. 1 hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regu , tions per the Cupertino Municipal Code, Section 9.18. Signature Date .44 ❑ OWNER- BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: I have and will maintain a Certificate of Consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, l shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that l have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signatu Date PHONE NO: JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL ❑ ETERNAL BEAUTY SKIN & LASER T.I. TO CREATE (N) OCCUPANCY FOR SALON WITH RECONFIGURATION OF INTERIOR AND M.E.P.'S (4,040 S.F.) Sq. Ft Floor Area: Valuation: $70000 APN Number: 35908020.20630 1 Occupancy Type: PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS F CALLED INSPECTION. Issued by: Date•,, - RE- ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE 1 have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should 1 use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino un cipal Code, Chapter 9.12 and the Health & Safety Code, tions 25505, 33, nd 25534. Owner or authorized agent: Dat 's® CO ENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional I CITY OF CUPERTINO BUILDING PERMIT 1 BUILDING ADDRESS: 20630 STEVENS CREEK BLVD I CON TR CTOR: GENERAL I PERMIT NO: 14120065 OWNER'S NAME: BYER OWNER'S PHONE: 4087788088 ❑ LICENSED CONTRACTOR'S DECLARATION License ClasssA� 5 Lic. # Contractor 40' t,. W i 'r6D " �/ Date 7iC1 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarati I have and will maintain a certificate of consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all n source gulations per the Cupertino Municipal Code, Section 9.18. Signature Date ❑ OWNER- BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). 1 hereby affirm under penalty of perjury one of the following three declarations: I have and will maintain a Certificate of Consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature. Date 11745 BENNETTA CT I DATE ISSUED: 02/05/2015 GILROY, CA 95020 1 PHONE NO: (408) 355 -0951 JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL ETERNAL BEAUTY SKIN & LASER T.I. TO CREATE (N) OCCUPANCY FOR SALON WITH RECONFIGURATION OF INTERIOR AND M.E.P.'S (4,040 S.F.) DEFERRED SUBMITTAL #I: ACCESSIBLE PATH OF TRAVEL FROM PUBLIC WAY AND STALLS. ISSUED 6- 29 -I5. r Sq. Ft IdWr Area: '� Valuation: $70000 APN Number: 35908020.20630 Occupancy Type: PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by: -✓ //, /Gf % Date: RE- ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with t ertino Municipal Code, Chapter 9.12 d the Health &Safety Cod , ections 2 5,255 and 2 534. Owner or authorized agent: Date: Z �� CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300TORRE AVENUE • CUPERTINO, CA 95014 -3255 CUPERTlNO (408) 777 -3228 • FAX (408) 777 -3333 • building cuoe:Jno.or ❑ NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION/TI REVISION / EFERRE ORIGINAL PERMIT 4 r - -►20065_ PROJECT ADDRESS %� / "S Yr AP R y o Q L/ OWNERNAME �� _,i P�I�EI V-O rk E -MAIL ST41) ADDRESS CTT T�TEZIP 1 FAX L G K�V A / CONTACT NA�(� G wJ7 ��,IAA ss7 f0— L -5 -1 'S fGOI STREET ADDRESS -7 # pC�IT�Y, ST�A�TE, ZIP 6A_ FAX ❑ OWNER ❑ OWNER- BUS -DER ❑ OWNER AGENT CONTRACTOR ❑ CON-TRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENA-NT CONn- LICENSE NUMBER _ T YPE LIC NCS�^E BUS. LIC COMP r R AV E FAX STREET AD CITY, STATE, ZIP 607Z P C + Al 07T� �,lr CA 'G ARCHITECT/Ej�GIN'EERN'PNE LICENSEN7Jh!BER BUS.LICR COMPANY NAME E -MAIL FAX STREET ADDRESS CITY, STATE; ZIP P E DESCRIPTION OF WORK F EXISTING USE PROPOSED USE CONSTR. TYPE ?STORIES USE TYPE OCC. I SQ.FT. VALUATION (S) EXIETG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL /-SEA PORCH AREA DECK AREA TOTAL DECK/PORCH ARE GARAGE AREA: DETACH ❑ ATTACH I I DWELLIN'G U?TITS: 1S A SECOND IJNrI' []YES SECOND STORY []1'ES BEING ADDED? []NO ADDITION? ONO PRE - APPLICATION [] 1 FS T' YES, PROVIDE COPY OF PLANWrNGAPPL4 ❑NO PLAA'NTNGAPPROVAL LETTER 1S THE BLDG AN ❑ YES EICHLERHOME? ❑NO RECEIV $� - TOTAL VALUATION: - . V By my signature below, I certi c cf the foll •inz: I am the p perty owner or authorized agent to act on the property owner's behalf. I have read this application and the inform n I It Ve provide s correct. I have r the De ription of Work and verify it is accurat . I agree to mply with all applicable local ordinances and state lam relating bui g construction. I autho ze repre ntatives of Cupertino to enter the ab ve dentified r e�tJy foAr inspection purposes. Date: Signature of Applicant/Agent: SUPPLEMENTAL I 4ATION REQUI D PLAn ci�cxTiPE zbr, .n. ,iibvrLnc'sLIP New SFD or Multifamily d\�re]linas: Apply for existing building(s). Demolition permit is required demolition permit for prior to issuance of build ing ot�Rr>covl.TEx z BUIIDIIsGPLaNREVJEiY permit for new building. EaPrss� PI Ai,I,L:cPLn. itEVIE�v = _ Commercial BldQs: Provide a completed Hazardous Materials Disclosure ❑ STAntinRD ❑`PUBLIC oRxs _ form if any Hazardous Materials are being used as part of this project Q gi ❑ L tRCE_ FIIZFnEPp4 _ Copy of Planning Approval Letter or Meeting -with Planning prior to ❑SATTTARYSER'ERDISTRICT - submittal of Building Permit application. - - .�-= ER'VIRON'vIEIST.4L`FiEALTA � - B1dgApp_3011.doc revised 05121111 CUPERTINO CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 (408) 777 -3228 • FAX (408) 777 -3333 • building @-cupertino.Orq �GO�S ❑ NEW CONSTRUCTION ❑ ADDITION 29 ALTERATION / TI ❑ REVISION /DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS APN N OWNERNAME",(02— PHONE E -MAIL mec, �� !7 STREET �pRJcS �/ /J CITyST � FAX 02 [Y�// ( ('�•`,H (jf / /^ — CONTACT NAME PHONE E-MAIL 403, 73i , vfZo F9zc--. r-A4 a FJ [ Y►scN ,C6M STREET ADDRESS CITY, STATE, ZIP FAX 7 70 ❑ OWNER ❑ OWNER- BUILDER ❑ OWNER AGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME Ir->—Yp-,1 LICENSE NUMBER LICENSE TYPE BUS. LTC k E3 z 7 Z COMPANY NAME N��ST E -MAIL FAX STREET ADDRESS ! (��� �E �d L �.i CITY, STATE, ZIP PHONE -655-4)591 � /S• 6 � I 4LA ARCHITECT /ENGTNEERNAME LICENSE NUMBER BUS. LTC k COMPANY NAME E -MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION F RK A � n rib S�P+' L\ 1 t—+ TE'121 a cs °3 (�>v 'CL- EXISTING USE PROPOSED USE CONSTR. TYPE # STORIES i ^Z V1--*-,L.--.4 T =iZgkC- USE TYPE OCC. SQ.FT. VALUATION (S) ExISTG NEW FLOOR DEMO TOTAL �I AREA AREA AREA NET AREA 40 (j L10 YU _ -$,_ BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECKIPORCH ARE GARAGE AREA: DETACH .40- -C::)- _A:�"— ; []ATTACH I s DWELLING UNITS IS A SECOND UNIT ❑ YES SECOND STORY C3 YES mil-' BEING ADDED? 5JNO ADDITION? aNO PRE - APPLICATION [-]YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YESh TOTAL VALUATION: PLATTING APPL k ❑ NO PLANNING APPROVAL LETTER EICHLER HOME? ®NO By my signature below, 1 certify to each of the following: I am the property owner Ize a5 roperty owner's behalf. 1 have read this application and the information I have provided is correct. I have read the Description of W veri is ac rate. comply with all applicable local ordinances and state laws relating to building construction. I t>thorize representatives of Cupertino ehe abo - identified property for inspection purposes. J Cate: Signature ofApplicant/Agent: ✓rL.f�— SUPPLEMENTAL INFORMATION u16LUIRED >P f' , New SFD or Multifamily dwellings: Apply for demolition permit for r� ' `a' existing building(s). Demolition permit is required rior to issuance of building OuERA ,BLUDTNG,PIlAI!i RE�11rV►' r' permit for new building. ©ExppxESSfi v �' �' +��PA G Ti,�T2EVtEyv <, ��� _ Commercial Bidgs: Provide a completed Hazardous Materials Disclosure D STiANDARD s 4 �ayPUBL CnVO SI' Y15 rlw �jP P" form if an Hazardous Materials are being used as art of this project. Y g P P J ❑D � , "' ^' ha' ys �, LAYtGE r a , FIRE�E$T .� g' _ Copy of Planning Approval Letter or Meeting with Planning prior to ❑ �, ❑ SEWER submittal of Building Permit application. MAJOR' SANITARY DI5; R14T" ENVIRUNIVIENTAIHEALTH� BldgApp_201 1. doc revised 06121111 FM_7 CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISION NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District. etc.). These fees are based on the areliminarv, information available and are only an estimate. Contact the Dent for addn'1 info. FEE ITEMS (Fee Resolution 11 -053 Eft.' 7%1113) ADDRESS: 20630 scb DATE: 03/10/2015 REVIEWED BY: Mendez rho r t APN: BP #: *VALUATION: 1$30,000 PERMIT TYPE: Building Permit PLAN CHECK TYPE: Tenant Improvement PRIMARY Commercial Building USE: Suppl. PC Fee: Reg. OTT-07 PENTAMATION 1 GENCOM PERMIT TYPE: WORK revise electrical plans [Tyj§jM#1 SCOPE NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District. etc.). These fees are based on the areliminarv, information available and are only an estimate. Contact the Dent for addn'1 info. FEE ITEMS (Fee Resolution 11 -053 Eft.' 7%1113) FEE QTY /FEE rho r t t= r t i. a i Y�C i Z� rjlfr i'( ET El Lj Suppl. PC Fee: Reg. OTT-07 NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District. etc.). These fees are based on the areliminarv, information available and are only an estimate. Contact the Dent for addn'1 info. FEE ITEMS (Fee Resolution 11 -053 Eft.' 7%1113) FEE QTY /FEE MISC ITEMS Plan Check Fee: Hourly Only? () Yes E) No $0.00 1 hours Plan Check, Hourly $143.00 1sTPLNCK Suppl. PC Fee: Reg. OTT-07 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee.-E) Reg. Q OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Work Without Permit? Yes (F) No $0.00 Advanced Planning Fee: $0.00 Select a Non - Residential Building or Structure 0 F_ Strong Motion Fee: IBSEISMICO $8.40 Select an Administrative Item Bldg* Stds Commission Fee: IBCBSC $2.00 SUBTOTALS: $10.40 $143.00 TOTAL FEE: $153.40 Revised: 02/14/2015 FM_7 CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISION NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District. etc.). These fees are based on the nreliminary information available and are onlv an estimate. Contact the Dent for addn'1 info. FEE ITEMS (Fee Resolution 11 -053 Ef.. Z /1/� ADDRESS: 20630 SCB DATE: 06/29/2015 REVIEWED BY: Sean Plan Check Fee: Hourly Only? © Yes Q No APN: BP #: "VALUATION: Iso PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Addition / Repair PRIMARY Commercial Building USE: I Civil / Religious activities in BQ zone. ® Yes Q No PENTAMATION 1 GENCOM PERMIT TYPE: WORK DEFERRED SUBMITTAL #1: ACCESSIBLE PATH OF TRAVEL FROM PUBLIC RIGHT OF WAY SCOPE AIVD ACCESSIBLE PARKING STALLS. NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District. etc.). These fees are based on the nreliminary information available and are onlv an estimate. Contact the Dent for addn'1 info. FEE ITEMS (Fee Resolution 11 -053 Ef.. Z /1/� FEE QTY /FEE MISC ITEMS Plan Check Fee: Hourly Only? © Yes Q No $0.00 1 hours Plan Check, Hourly $143.00 1STPLNCx Suppl. PC Fee: Q Reg. ©OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee-0 Reg. Q OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction Tax: IBCONSTAXC $0.00 Work Without Permit? Yes (F) No $0.00 Advanced Planning Fee: $0.00 Select a Non - Residential Building or Structure Strong Motion Fee: $0.00 Select an Administrative Item Bldg *, Stds Commission Fee: $0.00 SUBTOTALS: $0.00 $143.00 TOTAL FEE: $143.00 Revised: 05/07/2015 R M-7 CITY OF CLTPERTINO FEE ESTIMATOR - BUILDING DIVISION ADDRESS: 20630 STEVENS CREEK BLVD DATE: 12/15/2014 REVIEWED BY: MELISSA APN: 359 08 028 BP #: ` 5 "VALUATION: 1$70,000 PERMIT TYPE: Building Permit PLAN CHECK TYPE: Tenant Improvement PRIMARY Commercial Building USE: 4,040 PENTAMATION 1B TI PERMIT TYPE: 19 WORK ETERNAL BEAUTY SKIN & LASER T.I. TO CREATE N OCCUPANCY FOR SALON WITH SCOPE RECONFIGURATION OF INTERIOR AIVD NI.E.P.'S (4,040 S.F.) OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA s.f. PC FEES PC FEE ID BP FEES BP FEE ID B (Tenant Improvements) II- B,III- B,IV,V -B 4,040 $2,416.82 IBTIPLNCK $3,514.78 IBTIINSP $0.00 PME Plan Check: $0.00 Permit Fee: $3,514.78 Suppl. Insp. Fee-.(j) Reg. ® OT 0.0 I hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: TOTALS: 4,040 $2,416.82 $3,514.78 MECH, HOURLY Q Yes 0 No PLUMB, HOURLY Q Yes Q No ELEC, HOURLY Q Yes 0 No NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc.). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn'1 info. FEE ITEMS (Fee Resolution 11 -053 Eff 7.`1,13) FEE QTY /FEE MISC ITEMS Plan Check Fee: $2,416.82 Select a Misc Bldg /Structure or Element of a Building Suppl. PC Fee: (j) Reg. © OT FO. 0 1 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $3,514.78 Suppl. Insp. Fee-.(j) Reg. ® OT 0.0 I hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 0 G Work Without Permit? 0 Yes Q No $0.00 Advanced Planning Fee: $0.00 Select a Non - Residential Building or Structure G) i Stronv Motion Fee: IBSEISMICO $19.60 Select an Administrative Item Bldg; Stds Commission Fee: IBCBSC $3.00 SUBTOTALS: $5,954.20 $0.00 TOTAL FEE: $5,954.20 Revised: 1010112014 CUPERTINO TEMPORARY CERTIFICATE OF OCCUPANCY FORM COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 (408) 777 -3228 • FAX (408) 777 -3333 • building@cupertino.org APN? a c7 ' � - Q � p BP #: l o� (�Q DATE: G .2D f j PROJECT VALUATION: $ s ��• SITE / oZoocl St &Q 5 31Vd • ❑APPROVED I] APPROVED WITH CONDITIONS" ADDRESS: Y hr �S AM Date:...................... # ,'�iy� LIZ 8 � 5_64-6161 V 0 yJ eAV FAX #: MAILING ADDR SS (if differe from sit 9 esd : 0U o Sf Crc•ek 1v • ino CA- • ow CO TRACTOR n h k 4 ►� C p l PHONE #: FAX #: Y* &55 51 CO CT: f k i PHONE #: FAX #: qt 8' Y n i' ! Q TEMPORARY CERTIFICATE OF OCCUPANCY INFORMATION BgND TYPE: ❑ SURETY BOND AMOUNT (1% VALUATION BLDBONDS CODE CHECK ❑ CASH BOND OF BOND: 5K min -10K max $6)W0.00 tr EDITION: TCO EXPIRATION 71�4[a&5 DATE (6 MONTHS MAX): EE: 9E? MO TOTAL FEE: $ [1TEMPOCC] USE TYPE OF CONSTR FLOOR AREA OCC LOAD LEVEL COMMENT Public ors / �` ❑APPROVED I] APPROVED WITH CONDITIONS" Signature: ................ ............................. Date:...................... t er: Signature:......... . ............................... L Date - :72 j ..l.5. APPROVED ❑APPROVED WITH CONDITIONS" i OTHER DEPARfTT / AGENCY APPROVALS: z lanninq ..............`. ....... ............................... Signature: Date:........................ APPROVED I] APPROVED WITH CONDITIONS- Signature: ✓F...f� �R!�-....... Date:.`.!y'`}1� El' APPROVED APPROVED WITH CONDITIONS" Public ors / �` ❑APPROVED I] APPROVED WITH CONDITIONS" Signature: ................ ............................. Date:...................... t er: Signature:......... . ............................... L Date - :72 j ..l.5. APPROVED ❑APPROVED WITH CONDITIONS" `CONDITIONS OF COMPLETION - Attach a letter signed by the contractor and owner of the property stating the list of items required to be completed for each individual Department before final occupancy can be granted. Include approximate completion dates for each item. The undersigned covenant and agree as a condition to the approval of the above request for temporary occupancy to have the building or buildings complete and in compliance with all building codes, ordinances and regulations and ready for inspection prior to the expiration date specified. If this Temporary Certificate of Occupancy expires, the total amount of the bond may be forfeited and the non - compliance may result in -an enforcement action. vwi roi Sianature :. ........ .. ti...(.`/` .v Date:. 2414 s Swign an taucreid :. .......................... ............................... I Date:...................... This temporary certificate ensures that all fire protection and life safety systems have been completed, inspected, successfully tested and approved for the specific area of th building specified above to provide a reasonable degree of safety to the occupants from fire and similar emer encies. 2 �- �c Building Official: .............. . ....;:f........................ .....................Print:... Y..�... .�; .) rYi .......................Date:.�� -... -� .......... DEPARTMENT ACTION: After determination, copies to: 1) applicant, 2) permit file TempOccForm_2013.doc revised 717114 N BUILDING ENERGY ANALYSIS REPORT PROJECT: Eternal Beauty Skin and Laser Center 20630 Stevens Creek Blvd. Cupertino, CA 95014 Project Designer: Lynch Residential Designs 770 Cordova Court Morgan Hill, CA 95037 (408) 731 -0520 Report Prepared by: Darrel Kelly Builders' Energy Services 1478 Bird Avenue San Jose, CA 95125 (408) 202 -9075 BUILDER'S ENERGY SERVICES Job Number: 06051 Date: 12/8/2014 The Energy?ro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Enerq ✓Pro 6.3 by EnorgvSoft User Number: 1234 ID: 06051 I TABLE OF CONTENTS I Cover Page Table of Contents Form LTI -01 -E Indoor Lighting Form LTI -03 -E Indoor Lighting Power Allowance EnergyPro 6.3 by EnergySoft Job Number: ID: 06051 User Number: 1234 1 2 3 9 M-- i H 4 rr V o J LL Q O o0 a 0 iZ f v a E O V N c 0 z N u C a, Y w w T `0 c to m Q V a� C CL L N a, a1 c o m O o O +, O C O O CL Ou 0 v � O O C M Z) f a F- ❑ ❑ ® ❑ N tr1 � N 0 v `-' C U tw 3 3 a! C fl O � N Lx() Q U Q a° N a! O OD w ° W C vO O C N t CU u �E O t c � -o M v 0 O z U Q Q I v G1 =3 N ocn U d O O u � = m- O 0 L a z �n � u c O oD C c � OD N (D O c M C 7 -a C v O N + O U C) O O CL 0 3 o Q o O O v Z (1) z U °O w ° C n LL ® ❑ ❑ ❑ a1 O I i v o +_' c "O C O G C U C 7 U Z) c u n o c a <a c 0 3 C. O L C a; .� a �^ c o v 0 = H n U O +O+ C 0 O 0 � N o + _E v d C7 m ❑ a � v a E O V N c 0 z N u C a, Y w w T `0 c to m Q V 0 L N a, m O o 0 E CL 0 v a 41 o, N tr1 0 v `-' Cl) tw 3 3 W O Lx() Q U Q a° O W w ° W m cl •� �E O c O n 0 H J U J I v G1 =3 N ocn U d O � u � = m- 0 a z m z � a J C c � � N Q) c C 7 z O CL Q 0 c ° C n u n I i v c G f0 7 v n a c 0 m O O u ;° a N O N ,C3 0 N � Q + + u � d � c wm M N vm O ego N O C_ �, a=. ar U a1 v bD 0 O ro m O w a m w O N E m U o o o O O d 41 J w m C w -1 O N - c t O f O _v rI C O J f- w � LA C m N c V E U O U � a d w 0 = z w= m z t= lap z v ` d Q J C Q � c F- vi O � C CL u C O 7 a Q c � .n � J E 's t 3 c O 0 J N 0 N O ,C3 N Q N — a) E a 0 U 00 O O L O d V v Y Q c o o O t0 o 3 a c m o v m E c E T = O cI N M C V1 U 7 3 u ,C3 Q v 3 S E o „� b0 w C L H U O C L y � ai U u N 00 m Y O U D d0 J U C u W J Z L ° ° � �. � y en � •,� c N Ol � _ V J C H J w N W � w w w w w ° o 0 0 0 0 J J J J J .n p z z o w Z Z Z Z Z Z cw G � 7 w V i C o O Z LLJ Z •� 0 O O O a J a 0 v Z 6 w C3 U L° v a E O V N c 0 z N u C a, Y w w T `0 c to m Q V L a, m O o 0 CL 41 c N tr1 0 `-' Cl) tw 3 3 O Lx() Q U Q a° O W w ° W m cl O c O Ei 0 H J U J I G1 C U ocn U d O u � = m- 0 a z m z � J C c � � � C 7 O Q 0 C u I i c f0 � 0 O O u N O N 0 + + u d N °c°T wm M N vm .0 ego C_ �, a=. ar U a1 v bD 0 O ro m O w a m w O N E m U o o o O O d 41 J w m C w -1 = O-1 N - c L- O f O p rI C H J f- U H to N LA C m E U O U U d d0 c 0 = z w= m z t= lap z -O M N v ` y Q J C Q 3 F- CL u C O 7 a Q c � .n � J t c O 0 J a� 0 — 3 0 O c Q c o O t0 c E E T = O cI N M C V1 U v a E O V N c 0 z N u C a, Y w w T `0 c to m Q V 9) Z 4 = o' o J 20 op LLI -Z u) 4-► a 3 Q Q VI aJ m M N C w } J Z O � L L .Q 3: -4 d OD O U Q + LL t OD M J O 3 J o v _ U Q � Z ar C O O V a) al 3 O Q VI aJ 01 () M C w J Z O a) Q E O U -4 a) OD a a ?> W o M O Y J t U m J � � Z ar O � Q ++ c O U MI�MMMIV l (, f0 E L O L O L O L O H u Y 0 0 0 ar 0 L 0 0 a a a) (r a) a) C a) a) O a a ar a v a a a LL )• ❑ C C O C C C C u C aJ � ar ar v v v ar > a1 LL LZ LL LL LL LL ❑ ❑ ❑ ❑ ❑ ❑ aJ c6 Y s T) Q a-+ U O L O L u a C W i u u Q YLU E � O fo O N_ al E o +' aJ O 'A OD C 3 O S i aJ C O O C O _Lap i E c0 v ar ++ u + > V) O C io v t?o a a E v c C c v u OL L a' O u E to U a co U ++ u o L O O c O a v v v ar c Eo E E E co Q u 3 cc c77 cn Q Q Q w (0 u a) O O O J J J on E a-+ O u O U U U z C LL Z u c aCi Q C N m O o c Z I f6 C M °J V � co v to L v -0 a E W O W W ar V � i W f0 co to O C to LL f6 y w C u > N — O to ++ O a1 E t to E o C — pD fo aJ LL of O ate+ � C C Q1 L O V?7 O U U f6 ? M E C Y 7 f6 O OD C 2 OD CD 0 aJ Q N c6 3 7 t aJ to ++ OD C - O 0 _0 - v O O O O O O O O v O L U ++ Y ++ L+ C) ++ ++ O E Q •� a E a u Co N N N N u u v O o i W W N W a W O W W 1 O -:I' u O u v O p C:, O +, J J u J L J C J J C f6 M 7 a °' a -- W Z Z +, Z O Z u Z Z u Q C N to C O O m z '-7 o -0 r+ M V � co a u E Ln D ov r a, E L O L O L O L O u Y u w v ar ar L a a a > > C C C C c6 ar ar v LL LL LL ❑ ❑ ❑ O u C aJ a1 E 3 aJ c6 Y s C a-+ O u C L u a u Q E � O N O u E o u w O 'A OD i 3 O S L U C C O _Lap i c6 v ar ++ + > — C io v t?o a O N c C V u L a' E U a co U ++ L O O O V v v v ar E E E co Q u 3 cc c77 cn Q Q Q w (0 u a) O O O J J J O E u U U U z C LL Z Z Z Q C N O o c Z I f6 o � M V � co a p W W D v � 0 aJ Z 4 = rr o J LL Q �O op w P- 0 u Z L e O h v v -c rn o, t Oi J L O O h L 3 O CL rM O c o, v a c v Q C3 C3 v ttc 0 C3 c 0 c c a CJ W tjO U O Q U W O Q Z v O ii Z v M m h ❑ O v L Q a rM W c Z O J p: C3 Z as O v Q v C N M r`a a v vi c v E o 2 O Ln v In C On C vQ C a+ O On L U c OD C + — L � c Y O L CL N L ro c r' *' C ro O M CU 1 cL T c 01 i1 r9 •— c a ro N c a� c L ro a ° w 1 0 O 0 -o O a M ro c V Hc w c ai Z E U 0 L W v O L o _ 5. a) u N � d t u E W a O Z c C W x .Q Z c r�'o E t O L v ° on F_ *' U W 0 Z O r°po a � •'_' J a a 0 E W n U ry L ccN yC p O O 0 O N JV n 7 0 ~ v 0 O L O U W 30 N -p v _ p_ 2 _C c Hm on do c Z � bD F— o CO to v Vr -o° v o OC E v o 0 0 +� U Q u O O ° -C L o Z Q 0 N N c 3 0 o Fail ❑ ❑ ❑ ❑ ❑ v a ii U CL Pass ❑ ❑ ❑ ❑ ❑ Z 3 x O 0 p v - C m c C L n O t U v C L N 3 a On ra v p *' M E v U v E v CU 0 UO J — ai y is U O on d a o � t� CL E 7 W O Cy N L V) N N v O v T c H W J � c E E m 7 c � v L = V - x w M L O a Q M L N O CL c L O � c �p � N p M O CL ro l7 vl n o L L N v Q LL .v_, w w w e N a w w +L+ O ° L 0 O o _ 010 Q c Off. N ru H N N �� a-•i O ro � W N ° W C C5 3 ° ° o N Cy ea O v L LO a L a .� 0 oL > Square feet rq C: m -t- �E +' W of this office 3 C C p m 0 .a _j L0 c ++ V) On _ ro H v n v E f6 CU CU = m c u V L U ro N L N m O O H O O c C ° a vT O. a 3 C On 'a on r } , v� O N c � v L d v 0 u Number of U .� p •On c = 4, Luminaires C r x 3 H C W E m c v v v i 3 O LE u ro H U v c ,� O m a- C 3 N a + on T 1= O a °' O J c c r'o E N T On v _0 — � U ro f6 O c L p L o p E u c t0 E n O a o O C v L E CU E a E o c .a -J CU w v W .G Q c c c �� 5 L ro 7 fo (Lo U � _ � i ++ ~ 00. - a N L N aLU o a) .a a.. E ro O ai c V) 0 — '~ o ate+ H vU O is 0 V w •v— E L L O J C6 ❑ ❑ ❑ 0 N N c 3 W i O Cn Z J 0) oD �- o cU d s z v O N OD N T N d v a io C U N N (O J C CO _C Y U) W u �a C W z 0 H O z 0 U z D Eg (' ° Q ° Fail v U O Z J 0 ❑ [� Q Q a 0 r N G C- O ^ Z dr) W LL L z O O 110 LV .� 0 LL Q N J Q OD N a 0 LL U J z ❑ O O W O LL L 0 3 v u z Q G U � W v L ? U U X O a Q❑ c Q1 f0 C CL Q1 vi E C a) a/ 0 N � C m O L o U C D C '+� = O L � Y = f6 C Y U Y � 0 Y a- _0 CD (D U' C CO O C6 a) > O > N -0 n C C C a1 C6 — C f0 a1 C N C L E Q W O p Ln -0 0 Q J a/ t N � •� � z W v 0 L �O U a aa) U C � c - � m v u E z fl O W x 'Q z C U E +' a) 0 L O L Q U tlD Y Y L V C Ln U W 0 O to z J tl 0 L E W V U ++ LL aL O c _0 C -0 N LU - •- O D L -0 Q1 0 a) 0 0 C W 0 N 0 fl L L -O L _Z _w L M 0 Y O °D u C7 -°o v fi _ +� � it U a1 C E v O +� U Q O cua C C N a1 O Z Q v 0 v C 0 ° Fail ❑ ❑ ❑ ❑ ❑ bD ^ Cp C LL C. U a Pass ❑ ❑ ❑ ❑ ❑ Z 3 X O O � - c is c C L v O L U p v C L 3 v OD M v 0 . a O L Y C: — a) U N E 7 O O -I O J _ +O CU _ O OD o a E o CL w L dD C H �--� CU -0 Y >. C ~ W J M E CC E 0 0 Q L = V -0 � - W Y N O O O u C _0 L `O CCU C r0 r ^ n I7 0 O 0 a (D V vl ^ Q) — N U f6 0' LL W LL C .t a) C1 +� 0 �O C L O ° T m a 0 Q C V N CO C o � ° ++ r0 W to O 3 Q:3 0 O O v 3 0 6 v Q C CO bD .0 fl '> Square feet v W of this office 3 _ f6 O O rn o 0 L •Q LL C U Qv — y 'O W CU CU {n a1 E ^ - c u ++ O U f0 m Q1 L f6 m C w x Q1 CY6 ? O Y C CL 7 !0 O [D N O CL +L+ a - 3 L 00 C oD a1 r a E Number of U o m 3 U Luminaires o L _ L L JM (D c L CU � O E Q) ^^,, W in a, c v' v " a - � 3 U (LO L U m Y CC N �� O L �+ ♦Y OD 0 v O C •> O f6 E 3 C O f0 C E •CA O L O 00 N J •t3 a1 — a) L .M U Z U C L CO O C L O L O i •� E U C DO O it a) Q1 = Q a1 v v 0 3 �E Y a a, N 7 p C u E 0 C w v 0 0 v – 'O 0 C C (O L 7 Y M O a N c M a i U H M v 0 0 0 a 0 L O c_ M u O V EL E m o CO �o 0 = L y L — O m ❑ El El v 0 v C Z o J J L O 00 Z a c O h v v .c Oi G i L Ql s G O 13 v a. ti v 3 CL° rn G c J a c v v C3 H ,3 v G O •'O G O G G a CJ W G u o a Q y O 0 U W L Z 0 � 0 O Z v Ou W Z v � M h ❑ c� C v ,3 W � u Q a Uj H N � 0 c Z S?) O C3 Z J i 0 CL O Qj Q � v M _a E O U M c OJ C O Z r•n O N m in C Qj in v C W m m' d CL c = -o LL M ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ O + 3 M a `- = U M C T a 63 C U) ° `N o m w o �, E M U% O y C O C O d C c c m° U LL1 — W fO J LL E cv -0 C U N '- N y C '� Y II Co g g O E v N O ~ E L Y o U� 9 -a > i a w N 3 9 p 0 0 2 J J U J w Z Total Installed LL. Watts in this area ° v (CxE) o o° °° L v° 0 N 't M t` N CN Number J +N+ W Luminaires � O N lL7 00 CO M ~ LU Vf (7 Y M 3 According to El 11 11 El 11 El El 11 11 a U v v §130.0(c) Ln U = m v — 3 CEC Default ® ® ® ® S1 ® ❑ ❑ ❑ O = from NA8 W Q Z Ln W Z Z Watts per 0 u Luminaire o 0 0 0 0 0 UU') U') LO U') LO 00 W M CA Z J � W c LL O o .n w � � O u _ � O J 3 'p N v ai C N D O0 2 -1 _o W = U N E — M a E Co _ U d v E E 'fp aj p rn c6 Z C E a, O O Co > 3 F WW wwww o J J J J J J OO O O 0 LO 0 r` 0 Z$Ei wolI — Q .ro atusN U Q Q Q Q Q v M _a E O U M c OJ C O Z r•n O N m in C Qj in v C W m m' O O Ln z J a) O U g U fO 5 Z O N OD N v a d Ul 0 Z O c v U y io N J Z_ C N (6 LLI I � > Z cu cu Z m H > 0 �a l= O C: O LL (1) 0 J o O c W Q H L ni H LLI �o J n m E U � LL O U V LL z o0 o Fez °a v L) LLI 0 U) Z cwi v c v 0 d N C 6 v v y O O u ' u C N C co O c _n v v CL E E E 3 O V O co V N V V N > p L m N cu C -n aL CL E cu f6 C V -O C C O V C - o -o O v m ai o w o , Y Y c a E o v N cu C N '3 O N N O n -p O m v C j N N .a m O .3 V C L C Y -c E Y Y N _0 N C s N > On y Y n C °1 E n Y Oo O .. - LO 0 3 3 3 cV v c on .a c is -° ° P 0) N >� 61 Y °` oco o r o - N O N m aL-. .a M O C '^ n _ h w a' _ N c o o �° y `o c .t =p w u L N CU a c v w v L cu 41 N W6 C N y c v o C w O a ° > d f0 - L U ? y u n C M> On E z o a O u N O E 'O -O ,a C ti f6 w V m N c E n1 O CO o p w E o N C N -vi N n -O = m N 'a -O p_ E V c M � V - a, O O V v vi N �' ✓t v C c Y° o v E V 08 _ u f6 o N O Y n Y a E c E E w v 'O O d° L O y .`- V 'O N vii w 'O 3 N N (0 C O y M N O O N N � CO N C H is u N N 6 V T 3 WH C N fn E O d C N O V d V � C O 3 V 'O O y 'a - ,� H C N c ro H u U _ Z C 5 O f6 - y c 0 CL 1- O P ° °' C _. v '°0 N i6 I o N c o, n o fn N Z c (n 7 W Q N C w 'v, ut N ut n c o .-° �, 0) C C', _n O '-' m n E vi V N 61 H n > Q ZO Y �j ai c� N c c Q' 0 T C w Q U C: v, Y c E 'E ,n on " O a g _� a> p N H Y n o o v o 3 a c Y O ¢ c m m W° N "0 CO g-0 'O O cu Y a Y v N C cu _0 C 3 cu W 3 '° •] „� C m E O Q1 C, _ :c m cn 0 °cnop CD ° E L °u �y H �j Q ✓t E Q Cp C N jp C N O r6 0 ar E z Y Z z °' 3 w °° 3 y a z O 6 L W a 6 Eat 6 ? O v C cu >O 2 v ~ Y y c E EL io Q c -i w O ,� C N m .� N r N v Z y o a 00 c v o cu —nom E v v o a V > w Z V L f6 L O L o 3 c 7 > w - v vL V j O o o v + W °. v o ' i H O V Q K U Q U v 0 d W U z O J W O IL C9 z -, o—, J J Q LLO 00 U7 Z w W 3 O CL 0 K F- T C9 J a W O J J a 0 a c O L aJ DO a F- (1) d 0 W z 0 H 0 z 0 U z D v U 0_ LU LU z O F- E z C U 0 (A 3 m W V1 0) N m 0 U U oOn c a Y � w ivf 0 0 ° n U v E v a, W a F- W J In 0_ In c U Q a C m � c 0 Cl) O J m °) ai > O 0 0 > o Q O x E �o o Q O v Q ~ ~ Q 0 u _ W 3 co Y U a fa 0 Q Y 0 v C Y � �o a) H u r v c W M O co c Y S� O F- O 3 3 a) O J J 1D O � 3 Q) V v W co N L u c W ac° l7 Z w w Lz r a E 3 x Y O O J l7 m J 3 u J z_ N O 0 O x m F- tkb ~ C C __0 O LL 0 LU 0 d 0- O z CL O v) a O O v J_ o 2 m •m 3 o U W H J 0 W J 0 ° c � 0 O a Z In ca aJ = ca O w H � ai U cn _ + u ca O F J O V H O ro U U w ro a z o c L 0 Q Z V Ia W V Y U 0 O O w (Li z c r' u o U Z L 2 3 Y ? u QJ 0 o O O Q o W a E Q � - v 0 c W U 0 Q1 U v Gi fa 3 m o U y W a E o° E v vi (A V O U Z v Y E Q o o zY LL O 0 Y O 0 Q v) a a) m o m m oA r W Qi u o O -0 Q a E m U C m ) J v v C 00 � -0 Q C C: 0 41 ° f0 a Y v V1 Z3 o p ,t ,t- m o v .F u U Q H Q ❑ ❑ ❑ .-i N M (A 3 0) W V1 0) N m O a 3 U U oOn c a f0 0 0 ° n U v E v a, W a F- W J In 0_ In c U Q a C � c 0 O J m E ai > O 0 0 > Q O x �o o Q O v Q ~ ~ Q � O _ W 3 co Y U a 0 Q v C O �o H u v c W M O co W Z z Y S� O F- V) 3 3 m O J J 1D O � 3 Q) V v W co N L W ac° l7 Z w w Lz r a o L 3 x Y O J l7 m J J z_ 0 O x m F- W ~ C C LL 0 LU O 0- O z CL 0 O J_ H 2 O W H J W J a O O H U 0 C6 O (A 3 0) 0) N m U U oOn c c f0 0 0 ° n U U E v a, In w c o E E 0 0 > O �o m Q O O N ~ ~ 3 O Q C O u (Li i M O 1 U Y S� V) 3 m C. 3 V v m Y 0 N L W aJ Z w 3 Y O J m J m 0 NQN 1.1. F- W O CL O Z H 2 O J H O H 0 O H W O 0 W Q U Q W Q U 0 N a1 C a1 U a E 0 U N 0 z 0 N U m C T U C LU v w T La v c 0a C 7 m Q U W U Z 0 J W a Z Q 0 o LL —, J Q u0 LE a � Z L O T c O a m m 0_ L H V; C CL vcuc C 0 o � O Z u C p D 0 Z 0 u Cl) Z c 0 C O u 0 w O v � a U CL 7 U, LU � O mZ a O a t M 0 Z Co _ a Q 0 0 N a C 0 O Q Q J J > Q (o ti a0 N M O 00 N N N M N Il- CY 11 N Q u Q W c I Q ~ _ O c0 O 00 to _ 0- Li O N O co M � O u O X ,n u u J Q w � Z H N ~ O m p $ ~ O C W u 0 a O O +_� � O N � c O T � c U O U � C O *' a ca E Ln c 4l O U0 , 0 = c Z v a ,n Q a m O CL o 3 O L -I ca a ca 00 Q a v Q cn U 3 -+ u Lom W w tC C U 'C O c O O u O O 6 U C 3 C LL CD ` c D. to w. Ol .0 fn CD N O UO c a m U. (6 c0 +j Z Loo _ tD M >, O "O V O (0 U O O U H _ a O � •L .0 0 C U C 0 co v .a C7 0 w+ a o U 0 aoi Q C: J O Q E (0 J a O O Q u E W Z w W O 0 L E O C7 O 0 +� L OA SZ W C LU u O Y 2` L r W L 0 W d O O (n E Q fl ._ O Q) a �+ N u C O O U c v O J — N N O N 7 J �+ U (0 W tp �' O C', (0 QO o�j 0 >+ "d 'O O •C Y U CD �j El El -i U O U co 0 N a C Z 0 LL LL O w N �W V Z O J W O IL _Z V J O c Z v fa CL E 0 V io .D .N au O Z m ti O N �co T u C al 'u w T m a, Oa v CI] Q V v r 0 v v o c 'o u ai c m m o c Q E E o o = — V V V u - O O L m a al u O Y 'Q m C m L u O a E J V L C � �7 R u o O Y CO a 2 p tla '0 7a 7 al v a ° v D m v o 21 D Y w E o c a �O a to N C N 7 c N m 3 v ry o E C N N ,a � V C c w E N L Y .D N '� D C o N tto Y Y a T C N E L N L a v do U - �� o 3 3 v cc O C N 'D o m N> O 7 a) m o 00 `o N �N N _ a f0 O = CL u N _ c �o p m .� m .� - 'p aJ u p L Gl o > > T 3 N v a Id = v Y °� �� v c w o y O 'o p T n v v n u o o vii u a _a z o t a -- T u ,D - w U O E N u D fa _O C V f0 a1 C cw al N E C O O E _ O CO E p al `� a) N C Ul a 'O m N Q1 L 'D a E N V . al C 'o u , al f0 V= a, o w r- L ° v n Y v o a ° c o v c o m Y m E c E E m a) O d .D Lj Y 7 O V V O 'O V -L' N N T a Y N - cO C C O N N u O N aJ fm m C N (O 'p {uj al Y N u E c ~ N N -c C y C ? 'O E O v W E N U a C N a V = U O o v N n c m yy L to H Z Z D Y C V ' m O W p V a H CV in N to 3 aJ n— N O u V O a aJ N C T a° {A V Z T c O) W al C N N fa N o c m c �o O .Q � O ai u m N C a E? (D > U Q N z Y u N V- m o c 3 o (D -o a� O - N OD V O c E c �. N Y W m D a a Y o o v o a b C M V 'p O N °° N aJ n] 'a -D aYv3t -s LA m O O Ql N E L U V aL+ HU v Z C '3 a pCp N o m ro C Yp a a E Z O o 0 o v o a o L v E z z° c a V 3 ° z O o Y E W a m w a) T txo v y C> E Z Z a, o J Y C c� >, O C T ,D C N a .a .� Z+ o a m c v o v E v E v o a Y '^ v E° v E v u- ° —° v V j p. v in E 6 Y H W o. a v in Y o o d' v fa CL E 0 V io .D .N au O Z m ti O N �co T u C al 'u w T m a, Oa v CI] Q V LE L . I <A AN Celebrity® Single Bowl Sink SPECIFICATIONS Model GECR2521 Series - A.D.A. Compliant GENERAL Designed and recommended for use with GE undersink dishwasher. Good quality Celebrity sink bowl seamlessly drawn of #20 gauge, type 304 (18 -8) nickel bearing stainless steel. Self- rimming. DESIGN FEATURES Bowl Depth: 5 -3/8 ". Coved Corners: 3" vertical radius, 2 -1/4" horizontal radius. Bowl and Faucet Deck Recess: 3/16" below outside edge of sink. Finish: Exposed surfaces are machine polished to a bright Celebrity finish. Underside: Fully undercoated to dampen sound and prevent condensation. OTHER Drain Opening: 3 -1/2" as illustrated. Suffix "L" (left) or "R" (right) denotes drain opening located in Model GEOR2521 L3 HOLE DRILLING CONFIGURATIONS r,7__�.. left or right rear corner of bowl. C 0 NOTE: Unless otherwise specified, sink is f urn ishe i faucet holes as shown. These sinks comply with ANSI Standard A112 9. 2 OPTIONAL ACCESSORIES Rinsing Baskets: LKRB1520 and LKERBSS. SINK DIMENSIONS (INCHES)* *Length is left to right. Width is front to back. 21" 25" 3 -3/4" 21-1/4" 15 -3/4" 2" 2 -1 /4" R 5 -3/8" Model GECR25213 Illustrated Model GECR2521 L3 Illustrated 3/8" 1 21 -1/4" /4 " 3/4" 7r—MTR7 27 .I 77. 4 "-N-4" 3 -3/4" 4 -3/4" 21 -1/4" 4 -3/4" 15 -3/4" 3" R �2"1 21" 25" 1 -3/4" 2 -1/4" R 5 -3/8" Model GECR2521 R3 Illustrated THIS PRODUCT, AS CONSTRUCTED IS SUBJECT TO INTERPRETATION OF A.D.A. REQUIREMENTS. THE UNOBSTRUCTED KNEE SPACE REQUIRED TO SATISFY A.D.A. STANDARDS MAY NOT BE DESIRABLE. ALL DIMENSIONS IN INCHES, TO CONVERT TO MILLIMETERS MULTIPLY BY 25.4. In keeping with our poiicy of continuing product improvement, Elkay reserves the right to change This specification describes an Elkay product with design, quality and functional benefits to the product specifications without notice. user, When making a comparison of other producers' offerings, be certain these features are not overlooked. Elkay 2222 Camden Court Printed in U.S.A. Oak Brook, IL 60523 ©2003 Elkay www.elkayusa.com (Rev. 12/03) 1 -25F Cutout in No of Countertop 11/2" Dia. (11/2" Radius Faucet 31/2" Minimum Ship. Model Overall Inside Bowl Comers) Holes Drain Cabinet Wt. L W D L W Number L W 4" Centers Opening Size Lbs. GECR2521 25 211/4 21 153/4 53/8 243/8 205 /8 1, 2, MR2, 3 or 4 Off- Center 30 103/4 GECR2521 L 25 211/4 21 153/4 53/8 243/8 205 /e 1, 2, MR2, 3 or 4 Left 30 103/4 GECR2521 R 25 211/4 21 153/4 53/8 243/8 205 /e 1, 2, MR2, 3 or 4 Right 30 103/4 *Length is left to right. Width is front to back. 21" 25" 3 -3/4" 21-1/4" 15 -3/4" 2" 2 -1 /4" R 5 -3/8" Model GECR25213 Illustrated Model GECR2521 L3 Illustrated 3/8" 1 21 -1/4" /4 " 3/4" 7r—MTR7 27 .I 77. 4 "-N-4" 3 -3/4" 4 -3/4" 21 -1/4" 4 -3/4" 15 -3/4" 3" R �2"1 21" 25" 1 -3/4" 2 -1/4" R 5 -3/8" Model GECR2521 R3 Illustrated THIS PRODUCT, AS CONSTRUCTED IS SUBJECT TO INTERPRETATION OF A.D.A. REQUIREMENTS. THE UNOBSTRUCTED KNEE SPACE REQUIRED TO SATISFY A.D.A. STANDARDS MAY NOT BE DESIRABLE. ALL DIMENSIONS IN INCHES, TO CONVERT TO MILLIMETERS MULTIPLY BY 25.4. In keeping with our poiicy of continuing product improvement, Elkay reserves the right to change This specification describes an Elkay product with design, quality and functional benefits to the product specifications without notice. user, When making a comparison of other producers' offerings, be certain these features are not overlooked. Elkay 2222 Camden Court Printed in U.S.A. Oak Brook, IL 60523 ©2003 Elkay www.elkayusa.com (Rev. 12/03) 1 -25F r i 6540.170 Shown I (1- 132 ") MAX. 89mm (3-1/2' - — — — — i= 203mm (8.) GENERAL DESCRIPTION: MONTERREYTM TWO- HANDLE 8" WIDESPREAD LAVATORY FAUCET WITH RIGID /SWIVEL SPOUT 270mm (10 -5/8 ") 165mm (6 -1/2 ") 35mm (1 -3/8 ") DIA. MOUNTING HOLES __ 1/2" NPSM Durable cast brass construction. Cast brass valve bodies with 8" rigid copper connection with compression fittings. 1/2" male threaded inlet shanks with brass coupling nuts. 114 turn ceramic disc valve cartridges. Convertible rigid /swivel spout. Choice of Vandal- Resistant Lever or Wrist Blade handles with blue & red color indexes. All brass drain bodies with 1 114" (32mm) tailpieces (on applicable models). 1.5 gpm /5.7Umin. maximum flow rate. Vandal- Resistant and Laminar Flow aerators are available. MODEL NUMBER: ❑ 6540.170 Widespread Lavatory 1.5 gpm Pressure Compensating Aerator. Convertible dgid/swivel gooseneck spout. Vandal- Resistant Wrist Blade Handles. Less drain and pop-up hole. ❑ 6542.170 Widespread Lavatory 1.5 gpm Pressure Compensating Aerator. Convertible rigid/swivel gooseneck spout. Vandal- Resistant Wrist Blade Handles. Grid strainer drain. ❑ 6540.140 Widespread Lavatory 1.5 gpm Pressure Compensating Aerator. Convertible rigid/swivel gooseneck spout. Vandal - Resistant Lever Handles. Less drain and pop-up hole. ❑ 6542.140 Widespread Lavatory 1.5 gpm Pressure Compensating Aerator. Convertible rigid/swivel gooseneck spout. Vandal- Resistant Lever Handles. Grid strainer drain. PRODUCT FEATURES: Pressure Compensating Aerator: Provides a constant water flow of 1.5 gpm throughout the pressure range. Solid Brass Construction: Durable - Excellent in high use applications. Ideal for prolonged contact with water. Ceramic Disc Valve Cartridges: Assures a lifetime of drip -free performance. Field- Convertible Rigid/Swivel Spout: Easily converted in the field. Lead Free: Faucet contains 5 0.25% total lead content by. weighted average. SUGGESTED SPECIFICATION: Two handle widespread lavatory faucet shall feature cast brass valve bodies with 8" rigid copper connection. Shall feature water - conserving 1.5 gpm /5.7Umin. pressure compensating aerator. Vandal- Resistant handles. Shall also feature 1/4 turn washerless ceramic disc valve cartridges. Shall also feature convertible rigid /swivel spout. Fitting shall be American Standard Mode(# 654_._.002. L83 © 2013 AS America Inc. Revised 9/13 57mm (2 -1/4 ") I Lever Handle 127mm (5 ") _ 400mm _98mm —� (15 -3;4 ") (37/8--) 51m (2 ") DIA. TYR P. I (1- 132 ") MAX. 89mm (3-1/2' - — — — — i= 203mm (8.) GENERAL DESCRIPTION: MONTERREYTM TWO- HANDLE 8" WIDESPREAD LAVATORY FAUCET WITH RIGID /SWIVEL SPOUT 270mm (10 -5/8 ") 165mm (6 -1/2 ") 35mm (1 -3/8 ") DIA. MOUNTING HOLES __ 1/2" NPSM Durable cast brass construction. Cast brass valve bodies with 8" rigid copper connection with compression fittings. 1/2" male threaded inlet shanks with brass coupling nuts. 114 turn ceramic disc valve cartridges. Convertible rigid /swivel spout. Choice of Vandal- Resistant Lever or Wrist Blade handles with blue & red color indexes. All brass drain bodies with 1 114" (32mm) tailpieces (on applicable models). 1.5 gpm /5.7Umin. maximum flow rate. Vandal- Resistant and Laminar Flow aerators are available. MODEL NUMBER: ❑ 6540.170 Widespread Lavatory 1.5 gpm Pressure Compensating Aerator. Convertible dgid/swivel gooseneck spout. Vandal- Resistant Wrist Blade Handles. Less drain and pop-up hole. ❑ 6542.170 Widespread Lavatory 1.5 gpm Pressure Compensating Aerator. Convertible rigid/swivel gooseneck spout. Vandal- Resistant Wrist Blade Handles. Grid strainer drain. ❑ 6540.140 Widespread Lavatory 1.5 gpm Pressure Compensating Aerator. Convertible rigid/swivel gooseneck spout. Vandal - Resistant Lever Handles. Less drain and pop-up hole. ❑ 6542.140 Widespread Lavatory 1.5 gpm Pressure Compensating Aerator. Convertible rigid/swivel gooseneck spout. Vandal- Resistant Lever Handles. Grid strainer drain. PRODUCT FEATURES: Pressure Compensating Aerator: Provides a constant water flow of 1.5 gpm throughout the pressure range. Solid Brass Construction: Durable - Excellent in high use applications. Ideal for prolonged contact with water. Ceramic Disc Valve Cartridges: Assures a lifetime of drip -free performance. Field- Convertible Rigid/Swivel Spout: Easily converted in the field. Lead Free: Faucet contains 5 0.25% total lead content by. weighted average. SUGGESTED SPECIFICATION: Two handle widespread lavatory faucet shall feature cast brass valve bodies with 8" rigid copper connection. Shall feature water - conserving 1.5 gpm /5.7Umin. pressure compensating aerator. Vandal- Resistant handles. Shall also feature 1/4 turn washerless ceramic disc valve cartridges. Shall also feature convertible rigid /swivel spout. Fitting shall be American Standard Mode(# 654_._.002. L83 © 2013 AS America Inc. Revised 9/13 � " 11 x, CODES AND STANDARDS These products meet or exceed the following codes and standards: ASME A112.18.1 CSA B 125 NSF 61 /Section 9 and Annex G MONTERREYTM TWO- HANDLE 8" WIDESPREAD LAVATORY FAUCET WITH RIGID /SWIVEL SPOUT FLOW RATE' 2.0 W z' 1.5 ..�.� -� IL 1.0 ° 0.5 J Q 0 0.0 20 40 60 80 100 INLET PRESSURE (PSI) Flow rates shown are for mixed hot and cold. ©MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI Al 17.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE BUILDING FACILITIES -CHECK LOCAL CODES Other Aerators Available: Part Suffix Description L22 2.2 gpm (8.3 Lpm) Non - Aerated Laminar Flow Outlet LV22 2.2 gpm (8.3 Lpm) Vandal- Resistant Non - Aerated Laminar Flow Outlet V22 2.2 gpm (8.3 Lpm) Vandal- Resistant Aerator A15LV Anti - Microbial 1.5 gpm (5.7 Lpm) Vandal- Resistant Non - Aerated Laminar Flow Outlet LV15 1.5 gpm (5.7 Lpm) PCA Vandal- Resistant Non - Aerated Laminar Flow Outlet V15 .5 gpm (5.7 Lpm) PCA Vandal- Resistant Aerator LV10 1.0 gpm (3.8 Lpm) PCA Vandal- Resistant Non - Aerated Laminar Flow Outlet V10 1.0 gpm (3.8 Lpm) PCA Vandal- Resistant Aerator V05 0.5 gpm (1.9 Lpm) PCA Vandal- Resistant Non - Aerated Spray V035" 0.35 gpm (1.3 Lpm) PCA Vandal- Resistant Non - Aerated Spray 'PCA - Pressure Compensating "Meets Cal Green Code L84 Oc 2013 AS America Inc. Revised 9/13 Finish Polished Product Chrome Number Description 002 Widespread Lavatory with convertible rigid /swivel gooseneck spout. 1.5 gpm/5.7L/min pressure 6540.170 compensating aerator. Vandal- Resistant Wrist Blade Handles. Less drain and pop -up hole. 6542.170 Widespread Lavatory with convertible rigid /swivel gooseneck spout. 1.5 gpm /5.7L/min pressure compensating aerator. Vandal- Resistant Wrist Blade Handles. Grid strainer drain. Widespread Lavatory with convertible rigid /swivel gooseneck spout. 1.5 gpm /5.7L/min pressure 6540.140 compensating aerator. Vandal- Resistant Lever Handles. Less drain and pop -up hole. 6542.140 Widespread Lavatory with convertible rigid /swivel gooseneck spout. 1.5 gpm /5.7L/min pressure compensating aerator. Vandal- Resistant Lever Handles. Grid strainer drain. ©MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI Al 17.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE BUILDING FACILITIES -CHECK LOCAL CODES Other Aerators Available: Part Suffix Description L22 2.2 gpm (8.3 Lpm) Non - Aerated Laminar Flow Outlet LV22 2.2 gpm (8.3 Lpm) Vandal- Resistant Non - Aerated Laminar Flow Outlet V22 2.2 gpm (8.3 Lpm) Vandal- Resistant Aerator A15LV Anti - Microbial 1.5 gpm (5.7 Lpm) Vandal- Resistant Non - Aerated Laminar Flow Outlet LV15 1.5 gpm (5.7 Lpm) PCA Vandal- Resistant Non - Aerated Laminar Flow Outlet V15 .5 gpm (5.7 Lpm) PCA Vandal- Resistant Aerator LV10 1.0 gpm (3.8 Lpm) PCA Vandal- Resistant Non - Aerated Laminar Flow Outlet V10 1.0 gpm (3.8 Lpm) PCA Vandal- Resistant Aerator V05 0.5 gpm (1.9 Lpm) PCA Vandal- Resistant Non - Aerated Spray V035" 0.35 gpm (1.3 Lpm) PCA Vandal- Resistant Non - Aerated Spray 'PCA - Pressure Compensating "Meets Cal Green Code L84 Oc 2013 AS America Inc. Revised 9/13 Product Features • ADA & UFAS Compliant • No tools required contractor friendly Tear -To -Fit feature makes trimming fast • Universal design fits virtually all lavatory applications • Smooth, flush SnapClipTM fasteners firmly secure piping covers in place and are nonabrassive and reusable • Antimicrobial vinyl maintain sanitary conditions • Lock Lid TM on valve stops tampering and allows service • Cleanout nut cap allows service on trap without disassembly • Internal ribs enhance K valve and soften impact cushioning • Fire retardant Model Numbers - PF200WH PF202WH PF201WH PF203WH PF205WH PFEXT299WH PF299WH PFEXT200WH Material Soft, resilient molded vinyl Nominal Wall 1/8" constant with internal ribs Durometer 70 -80 — Shore A UV Protection Will not fade or discolor Durability Virtually indestructible Trimming E -Z Tear -To -Ft trim feature (no tools needed) Fasteners Internal E -Z Grip fasteners, reusable Color China white Compatibility Fits all 1 -1/4" or 1 -1/2" cast brass or tubular P -trap assemblies and 3/8" or 1/2" angle stop assemblies Paintability Apply latex paint Burning Characteristics ASTM D -635 Self extinguished 0 sec (ATB) mm (AEB) Bacterial /Fungus Resistance ASTM G21 and G22 — Result: 0 growth Maintenance Wipe clean using common detergents New E -Z Tear -To -Fit feature and E -Z Grip built -in fasteners make installation fast and easy! 1. Tear -To -Fit on internal, dimensioned tear lines for quick, clean, accurate trimming to fit virtually any piping configuration. Covers flex to install over pipes. 2. Press seams together at finger recesses to engage E -Z Grip internal fasteners for a secure, safe, tamper- resistant installation. To remove cover, firmly pull seam apart using a strong grip, To reinstall, press seams back together. PF201 WH Product Specifications Shown with Accessory PF205WH (MS an standard 5 offset wheelchair Miners). Nate: Accessory PF205WH is Included In PF20304 6" supply tube cover/ with kdemat Gip E•Z Internal fasteners Vent slols keep 10'tallpiece rover _ ;... ti valve dry Inlemal E -Z Tear.Rb Fit trim Internal ribs add cushioning and thermal resistance J -ee W covers all tubular and cast brass configurations 10' waste aim cover with Internal E-Z 7aer•7o- Fiftrim grooves e keeps P•trap dry PF200WH one P -trap cover PF201 WH one P -trap cover, one angle valve and supply cover PF202WH one P -trap cover, two angle valves and supply covers PF203WH one P -trap cover, two angle valves and supply covers, one 5" offset tailpiece wheelchair strainer cover PF299WH one angle valve and supply cover PF205WH one 5" offset tailpiece wheelchair strainer assembly r,,r s � au PFEXT299WH one 16" extension for water supply PFEXT200WH one 16" extension for drain waste or tailpiece Warranty and Codes This PROFLO product carries a 1 -year limited warranty. This product meets ADA article 4.19.4; CABO /ANSI 4.20.4; UFAS 4.19.4; California Title 24; UPC /IAPMO ICC; Canada Barrier -Free Code. Made in USA. � PC C O © 2007 Wolseley Distributed Exclusively by Ferguson, Stock Building Supply and Wolseley Canada 0367 10/07 KOHLER, Features . Vitreous china . Wall -mount . With hanger . With overflow . Drilled for concealed arm carrier . Optional soap dispenser hole on left ( -L) or right ( -R) . F (203 mm) centers, 4" (102 mm), centers or single hole . 21 -114" (540 mm) x 18 -1/S" (460 mm) Codes /Standards Applicable Specified model meets or exceeds the following: . ADA . IMANSI A 117.1 . CSA 8651 . OBC . ASME A 112.19.21CSA B45.1 Specified Model WALL -MOUNT LAVATORY K -2005 ALSO K -2006, K -2007 ADA CSA 8651 OBC Colors /Finishes . 0: White . Other: Refer to Price Book for additional colors /finishes Accessories • CP: Polished Chrome • Other: Refer to Price Book for additional colors /finishes Model Description Colors/Finishes K -2005 Lavatory with 4" (102 mm) centers less soap dispenser hole 130 ❑ Other K- 2005 -L Lavatory with 4" (102 mm) centers with soap dispenser hole on left ❑ 0 ❑ Other K- 2005 -R Lavatory with 4" (102 mm) centers with soap dispenser hole on right ❑ 0 ❑ Other K -2006 Lavatory with 8" (203 mm) centers less soap dispenser hole ❑ 0 ❑ Other K -2007 Lavatory with single hole less soap dispenser hole 130 ❑ Other K- 2007 -L Lavatory with single hole with soap dispenser hole on left ❑ 0 ❑ Other K- 2007 -R Lavatory with single hole with soap dispenser hole on right 130 ❑ Other Recommended Accessories K -8998 I P -Trap ❑ CID TO Other Product Specification Lavatory shall be made of vitreous china. The lavatory shall be 21 -1/4" (540 mm) in length and 18 -1/8" (460 mm) in width. Lavatory shall be wall- mounted with hangers. Lavatory shall have 8" (203 mm) centers (K- 2006), 4" (102 mm) centers (K- 2005), or single hole (K- 2007). Lavatory shall have overflow. Lavatory shall be drilled for concealed arm carrier. Lavatory shall have optional soap dispenser hole left ( -L) or right ( -R). Lavatory shall be Kohler Model K- - Page 1 of 2 USA/Canada: 1- 800- 4KOHLER 116611 -4 -CL (1- 800 -456 -4537) www.kohler.com Technical Information Fixture': Basin area 16" (406 mm) x 10" (254 mm) Water depth 3 -1/8" (79 mm) Drain hole 0 1 -3/4" (44 mm) ' Approximate measurements for comparison only. Holes K -2005 K -2006 K -2007 Spout 0 1 -1/4" (32 mm) 0 1 -3/8" (35 mm) 0 1 -3/8" (35 mm) Faucet 0 1-1/4" (32 mm) 0 1 -3/8" (35 mm) Soap dispenser 01 -1/4" (32 mm) 01 -1/4" (32 mm) Included components: Hanger 64839 Concealed Arm Hole Location 1/2" (13 mm) 4" (102 mm) 13 -3/4" r(�1'6 " (349 mm) mm) K - 2006 2" (51 mm) 4" (102 mm) Installation Notes Install this product according to the installation guide. Will comply with ADA when installed per Section 606 Lavatories of the Act. Will comply with CSA B651 when installed per Clause 4.3.3 of the standard. Will comply with OBC when installed per Clause 3.8.3.11. 3 -3/4" (95 mm) Faucet Holes 8 -3/8" (213 mm) 18-1/8" (460 mm) Leveling - -- Screw Slot 0 1 -1/4" (32 mm) t " Leveling Screw 17-1/4" (438 mm) 1 -1/4( 32 mm) Hole Locking Device 21 -1 /4" (540 mm) Hole 8 -1/4" (210 mm) — 12 -- - rl—, 5" (127 mm) (305 mm) 4 -3/8" 7 -1/4" (111 mm) (184 mm) 33 (845 mm) Hot 3/8" Cold 29-1/8" (740 mm) �1 -1/4" OD 12 -7/8" mm) (327 mm) Standard Installation KINGSTONTM WALL -MOUNT LAVATORY Page 2 of 2 11 6611-4-CL Product Diaaram K -2005 -L 4" (102 mm) -R 4 -1/4" ` 3 -3/4" (108 mm) 1(95 mm) 31" 4 -1/2" ( 11 4 mm) (787 mm) K -2007 -L 4 -3/8" (111 mm) -R 4 -1/4" 3 -3/4" - (108 mm) �(95 mm) THE BOLD LOOK of KOHLER. K�H�R. Features . Metal construction • One - piece, self - contained ceramic disc valve allows both volume and temperature control • Temperature memory allows faucet to be turned on and off at any temperature setting • High- temperature limit setting for added safety • 4 -114" (10.8 cm) spout reach • Stationary spout • Metal throat plate • For 4" (10.2 cm) centers • Available with flexible connections or ground joints o Less drain . 1.5 gallons (5.7 liters) per minute maximum flow rate Codes /Standards Applicable Specified model meets or exceeds the following at date of manufacture: . ADA . ASME A 112.18.11CSA B 125.1 . ICC /ANSI A117.1 . NSF 61 • All applicable US Federal and State material regulations • EPA WaterSense® Specified Model CENTERSET LAVATORY FAUCET K -15199 atierSe'� m 0zQ 0'S EPA�� 'AMC RAT Colors /Finishes . CP: Polished Chrome Model Description Colors/Finishes K- 15199 -F Centerset lavatory faucet — flexible connections ❑ CP K-1 5199-P Centerset lavatory faucet — ground joints ❑ CP Optional Accessories 1160594 Large Spray 0.35 gpm (1.32 Ipm) — Insert only ❑ NA Additional flow options are available (refer to the Price Book) ❑ NA Product Specification The single - control centerset lavatory faucet shall be of metal construction. Product shall have a maximum flow rate of 1.5 gallons (5.7 L) per minute. Product shall feature a one - piece, self- contained ceramic disc valve, which allows both volume and temperature control. Product shall feature temperature memory, allowing the faucet to be turned on and off at any temperature setting, and a high- temperature limit stop for added safety. Product shall have a 4 -1/4" (10.8 cm) spout reach, stationary spout, metal throat plate. Product shall be for 4" (10.2 cm) centers. Product shall be available with flexible connections or ground joints. Product shall be less drain. Faucet shall be Kohler Model K- 15199- -CP. Page 1 of 2 USA/Canada: 1- 800- 4KOHLER 115837 -4 -AG (1- 800 - 456 -4537) www.kohler.com Installation Notes Install this product according to the installation guide. ADA compliant when installed to the specific requirements of these regulations. K- 15199 -F 5 -1/2" (14 cm) 1 -5/8" (4.1 cm) Max 22" (55.9 cm) K-1 5199-P 6" (15.2 cm) 3 -5/8" (9.2 cm) Product D (1 2 " (10.2 cm) -3/4 (7 cm 5" (12.7 cm) ram 4 -1/4" (10.8 cm) 1 -1/4" (3.2 cm) CORALAIS® CENTERSET LAVATORY FAUCET THE BOLD LOOK Page 2 of 2 115837 -4 -AG OF KOH Aft © "THERMOSTATIC" MICRO PROCESSING TEMPERATURE CONTROL Instant Comfort... Endless Sauings ELECTRIC TANKLESS WATER HEATERS 9,o6 MODELS: Thermostatic Options Volts kW Amps EX2412T S,FS,PDR 120V 2.4kW 20A EX3012T S,FS,PDR 120V 3.OkW 25A f} \ T f EX3512T S,FS,PDR 120V 3.5kW 29A EX48T EE,ML,S,P,FS,DR 240V' 4.8kW 20A EX55T EE,ML,S,P,FS,DR 240V' 5.5kW 23A • EX65T EE,ML,S,PFS,DR 240V' 6.5kW 27A EX75T EE,ML,S,P,FS,DR 240V' 7.5kW 32A Emergency EX95T EE,ML,S,P,FS,DR 240V' 9.5kW 40A Eyi ace Wash EX8208T EE,ML,S,P,FS,DR 208V 8.3kW 40A Fountains EX60T EE,ML,S,P,FS,DR 277V 6.OkW 22A EX80T EE,ML,S,P,FS,DR 277V 8.OkW 29A EX90T EE,ML,S,P,FS,DR 277V 9.OkW 33A EX100T EE,ML,S,P,FS,DR 277V 10.OkW 36A C o 'Units can be used at 208V with 25% reduced output. SPECIFICATION OPTIONS O EE = Emergency Eyewash 'Tepid Water" ANSI 2358.1 O ML = Multiple Lays (5.5kW - 10kW) CS = Sanitation Setting 1800 OP = Photo Setting temperatures atxktrient to 1000 O FS = Factory set temperature f arnbteuz# tri' 180 °� p DR= External temperature control LED temperature.display (see °Digital Readoe spec sheet) ` APPLICATIONS: • Dishwashers, Boosters (to 180 °F) (S) • Single and multiple handwash sinks maintain precise outlet temp for one, two, or three sinks code compliant (.5 GPM @ 105 °F)(ML) • Multi Station Modular Sinks • Emergency eye wash fountains (EE) • Metering and sensor faucet compatible • Low volume shower handset (.7 -2 GPM) • Photo Processing (P) • Schools /Hospitals /Nursing Homes/Laboratories • Eliminate wait for hot water, long pipe runs • Maintains accurate temperature continuously +/— 1 OF MADE IN USA Multiple Sinks r., I& Low Volume Hand Shower (.7 GPM - 2 GPM) Boosters for Sanitation ADVANCED TECHNOLOGY • HIGHEST EFFICIENCY • DESIGNED FOR DURABILITY QUALITY FEATURES • Fully Adjustable Temperature Range between 100 -140" Special settings of higher or lower range available upon request. (see spec options) • Eliminate Costly Mixing Valves. • On Demand Hot Water - no delay. Continuous Hot water - no storage capacity to run out. • Reduces Installation Cost and Material - no T & P relief valve needed (check local codes). • Easy Installation - only one cold or hot water line need be brought to installation - integral compression fittings for 1/2" pipe (5/8" OD) on bottom (no sweat connections). • Cut Energy Waste - flow switch activates heater only on demand (no standby heat loss) - 99% efficient. • Sophisticated microprocessing temperature control • Prevents Legioneila Bacteria Growth. • Meets ANSI 2358.1 Tepid Water Requirements • Anti -scald Protection. Reduce wide temperature fluctuation. • Reduces Calcification, Liming and Sedimentation. • Complies with Handicap Requirements. • Compact Size - dimensions 10.75 "x5.25 "x2.87' weight 3 lbs. • Field Serviceable Element - replaceable cartridge element (1 year warranty). • Warranty - Full Factory Warranty - Heaters are guaranteed against failure due to leaks of "Heater Body /Element Assembly" for a period of FIVE YEARS. • High Temperature Limit Switch - protects against element burn out, with reset button THERMOSTAT OPTIONS • Standard unit has fully adjustable thermostat 100- 1"40° • Higher temperature available up to ` °F upton request. (S) • "Digital Readout", external temperature ' "adlusient rangy 2.4 kW - 32 kW. (see "Digital Readout",spee�f�i (DR) • .Factory set, nonadjustable thermostat avarlable K �FS� � '' • Photoprocessing unit lower temperature range ami ent to 1b0° (P) • `Tepid" warm water (60° - 95 °F). for Errtergenpy Eye wash fountains available. Corrtplres',MdFi ANSI X 58.1 {EE THERMOSTAT ACCURACY ` • Thermostatic feature maintains +/– i °F accuracy.' • Achieves full, pre - selected outtet temperature within 10 seconds after activation. • Maintains consistent temperature. SUGGESTED SPECIFICATION Tankless Water Heater shall be an Eemax Thermostatic Model, with microprocessing temperature control capable of maintaining outlet temperature of +/– 1 °F accuracy, , with kW, model # kW rating vac, and to heat GPM @ a voltage amperage temperature rise of degrees F. Unit shall have ABS -UL 94Vo rated cover. Element shall be replaceable cartridge insert. Unit shall have replaceable filter in the inlet connector. Element shall be iron free, Nickel Chrome material. Heater shall be fitted with t/z" pipe compression nuts (5/8" OD) or 3/8" sleeves, to eliminate need for soldering. Maximum operating pressure of 150 PSI. Hot water storage tanks prohibited. Unit shall be Eemax or approved equal. RATINGS OF "THERMOSTATIC" MODELS ( cold or hot water feed ) MODEL THERMOSTATIC OPTION VOLTS kW AMPS TEMPERATURE RISE °F MINIMUM RECOMMENDED WIRE 0.5 GPM 0.75 GPM 1.OGPM 1.5 GPM 2.0 GPM EX2412T S,P,FS,DR 120V 2.4kW 20A 330 220 160 110 80 10AWG EX3012T S PFS DR 120V 3.OkW 25A 410 270 200 140 100 1 OAWG EX3512T S PFS DR 120V 3.5kW 29A 480 320 1 240 160 120 10AWG E:X48T EE,ML S PFS DR 240V* 4.8kW 20A 650 440 320 210 160 12AWG EX55T EE ML S PFS DR 240V* 5.5kW 23A 750 500 380 250 190 10AWG EX65T EE,ML S,PFS,DR 240V* 6.5kW 27A 890 590 440 300 220 10AWG EX75T EE ML S PFS DR 240V* 7.5kW 32A — 680 510 340 260 8AWG EX95T ML S PFS DR 240V* 9.5kW 40A — 870 650 430 320 8AWG EX8208T ML S PFS DR rEE 208V 8.3kW 40A — 76° 57° 38° 28° 8AWG EX60T ML S P FS DR 277V 6.OkW 22A 810 550 410 270 200 10AWG EX80T EE ML S P FS DR 277V 8.OkW 29A — 730 550 360 270 1 OAWG EX90T I EE ML S PFS DR 277V 9.OkW 33A — 820 610 410 310 8AWG EX100T EE,ML,S,P,FS,DR 277V 10.OkW I 36A — 910 680 46° 340 8AWG ' Units can be used at 208V with 25% reduced output and amperage. THERMOSTATIC TEMPER E, CATURONTROL >' SPECIFICATION OPTIONS ❑ EE _ (Emergency Eye Wash);to specify tepid water thermostatic units. Example � r Flows greater than 3 GPM:r risult "9e iesT�uo " N, Mcidels) or "Throe Phassen.(T3 [ ladela c aturat " r, r I ❑ ML = (Multiple Lays) .5 GPM x one tNo ar thFee hattdwash lays, fa ory set temp f Q6 wah � ' Example: X95T L. {includes.o�ni% two, ar free 5 GPM aerators {EX61) 6t quarrtpties DS = (Sanitation Setting) thermostat set f84 lrxampte ❑ P = (Photo Setting) temp er res'lowerxf ❑ FS = (Factory Set) temperature arrtbrent #a 1°Exarala EC95t`S 'i (t5° ❑ DR = External temperature control, LED temperature display (see " Digital Readout" spec SPECIFICATIONS: 93/4' Dimensions: 10.75 "x5.25 "x2.78" 10 3/4 Weight: 3 lbs. Cover: ABS UL rated 94Vo. Color: White Standard temperature range 100 °F -140 °F G us .Element: Replaceable Ni Chrome cartridge insert OUTI..ET r--+ INLET l-- Fittings: 1/2" pipe compression fittings at bottom of unit. (5 /a" OD) «D UL Listed: E86887 (M) U.S. Patent #'s: 4,762,980 and 4,960,976 SPECIAL INQUIRIES FOR UNITS FOR UNIQUE DESIGN APPLICATIONS ARE WELCOME. CALL SERVICE OUR TECHNICAL SERVICE DEPT. 1- 800 - 543.6163 EEMAX SUBMITTAL Engineer /Architect: Job Name /Customer: , Location: Contractor: Representative: HEATER SPECIFICATIONS: Thermostatic Model # EX -T Option Quantity kW Voltage AMPS GPM Telephone: (203) 267 -7890 E e m ax® Inc. www.eemax.com Toll Free: 1- 800 - 543 -6163 353 Christian St., Oxford, CT 06478 Fax: (203) 267 -7975 KOHLER, Features • Vitreous china. • Two -piece toilet. • Comfort Height® Elongated bowl. ' Class Five® flushing system. ' Includes left -hand polished chrome trip lever. • 1.6 gpf (6.0 Ipf). • 2 -1/8" (54 mm) fully glazed trapway. ' 12" 305 mm) rough -in. • Less seat and supply. • 11 -3/8" (289 mm) x 8" (203 mm) water area. ' 29 -3/4" (756 mm) x 18" (457 mm) x 31 -1/4" (794 mm). ' Floor mount / Floor outlet. Recommended Accessories K -4636 Toilet Seat K -4688 Toilet Seat K -7637 Angle Supply with Stop (single) K-4731 -C Commercial Heavy -duty Toilet Seat Components Product includes: K -4468 Toilet Tank K -4199 Comfort Height® Elongated Bowl Additional included component/s: Tank cover, Trip lever, Bolt cap accessory pack, and Tank accessory pack. Highlinea Class Five® Toilet K -3979 ADA SA 113651 OBC Codes /Standards ASME All 12.19.2 /CSA B45.1 DOE - Energy Policy Act 1992 ADA ICC /ANSI All 17.1 CSA B651 OBC KOHLER® One -Year Limited Warranty See website for detailed warranty information. Available Color /Finishes Color tiles intended for reference only. Color Code Description USA/Canada: 1- 800- 4KOHLER (1- 800 - 456 -4537) THE BOLD LOOK www.kohler.com 12-18 -2014 02:50 OF KOHLER® 0 White J 96 Biscuit , 47 Almond 0 7 Black Black'- USA/Canada: 1- 800- 4KOHLER (1- 800 - 456 -4537) THE BOLD LOOK www.kohler.com 12-18 -2014 02:50 OF KOHLER® KOHLER, 3/4" (19 mm) 2 -3/4" (70 mm) Finished Wall i O O — 29 -3/4" (756 mm 8 -1/2" (216 mm) --I 16-1/2" (419 mm) 12" (305 mm) T_ of Outlet Technical Information All product dimensions are nominal. Toilet type: Two -piece Bowl shape: Elongated front Highline® Class Five® Toilet K -3979 F For Back -to -Back Toilet Installations I I I � I I � Use a 45° double Do not use a wye fitting. double sanitary tee -1 — L ------------ - - - - -� 18" `(457 mm)—' } 31 -1/4" (794 mm) _F_ - 5" (127 mm) 3/8" NPT Supply/ 4 -1/2" (114 mm) Flush type: Class Five Trap passageway: 2 -1/8" (54 mm) Water Consumption Full: 1.6 gpf (6 Ipf) Water surface size: 11 -3/8" x 8" (289 mm x 203 mm) Rim to water surface: 5 -3/8" (137 mm) Rough -in: 12" (305 mm) Seat - mounting holes: 5 -1/2" (140 mm) Front of Bowl 1 16-5/8" (422 mm) 10-1/4" (260 mm) 10-1/8" (257 mm) \ Finished Floor Notes Install this product according to the installation guide. For back -to -back toilet installations: Use only a 450 double wye fitting. ADA, OBC, CSA B651 compliant when installed to the specific requirements of these regulations. The Model Plumbing Codes require the installation of elongated open -front toilet seats on public bathrooms. USA/Canada: 1- 800- 4KOHLER (1- 800 - 456 -4537) FHE BOLD LOOK vvww.kohler.com OF KOHLER® 12 -18 -2014 02:50 BEMIS COMMERCIAL t PLASTIC HINGES WITH STAINLESS STEEL POSTS AND PINTLES STA -TITE® COMMERCIAL FASTENING SYSTEMTm COMMERCIAL HEAVY -DUTY PLASTIC TOILET SEAT 1955CT/1955SSCT Open front less cover, elongated, heavy -duty, injection molded solid plastic toilet seat. Features four molded -in bumpers, non self - sustaining (1955CT) or self- sustaining (1955SSCT) check hinges with non - corrosive 300 Series stainless steel posts and pintles and STA -TITE® Commercial Fastening SysteM`rm. This seat complies with American National Standard Z124.5 Toilet (Water Closet) Seats as a class Commercial Heavy Duty. Size: Elongated Material: Plastic Style: Open Front less Cover Bumpers: Four Hinges: Plastic Non Self- Sustaining (1955CT) or Self - Sustaining (1955SSCT) with 300 Series Stainless Steel Posts and Pintles Fastening System: STA -TITE® Commercial Fastening System"" STA -TITE® Commercial Fastening SystemT"" Non - Corrosive 300 Series Stainless Steel Posts and Pintles 5 -1/2" Proudly Made in the USA Bemis Manufacturing Co., Sheboygan Falls, WI 53085 www.BemisSeats.com 18 -3/8" �1-7/8" 1-4--l-1/16" Phone: 920-467-46211800-558-7651 Fax: 920 - 467 -8573 7ffix,1621 U-Ifew 0, 'Anfo r .mm Endless Sauings OPTIONS PC = Flex Connector braided - stainless steel water connections available. (EX176, EX177) Example: SP3512FC Shopping Malls Office and Tenant Spaces Commercial Buildings (restaurants, etc.) Modular Buildings /Modular Offices Public Hand Washing Service Stations Schools Concessions Stands, Stadiums Designed to comply with .5 GPM handwashing code target outlet temperature 1050 - 110°. ADVANCED TECHNOLOGY e HIGHEST EFFICIENCY DESIGNED FOR DURABILITY ...._::u iHot :Vater no delay. paste -flow switch activates heater only on demand ino standby heat loss). 99 % efficient ho yvw':er - no storage capacity to run out. _stallzatio, , Cost - no T & P relief valve needed (check local codes). ,.:. .:.J� Or, -only one cold waterline need be brought, to :avatory - integral 3/s° compression fittings on ,op 01c sweat connections). Mounts on wall at point -of use :. .. esirctor - Built in to ensure proper temperature rise. Complies with U.S. Federal regulations. -with excellent spray pattern supplied with unit. :. :.._., _._a, sensor and metering faucet compatible MADE IN USA • Prevents i_egicnella Bacteria Growth • Reduces Liming, Calcification and Sedimentation. • Complies with Handicap Requirements • Ni Chrome Element - a unique, patented flow path ensures optimum heat transfer and extended element life. • Compact Size - dimensions 10.75"x 5.25"x 2.875"; weight 3 lbs. • Field Serviceable Element - replaceable cartridge element (1 year warranty). • Warranty - Full Factory Warranty - Heaters are guaranteed against failure due to leaks of "Heater Body /Element Assembly" for a period of FIVE YEARS. • High Temperature Limit Switch - protects against element burn out, with reset button. tS M Amps SP24 ` �2: 120V 2A W 20A SP301 % 120V 3.OkW 25A SP351,_ 120V 3.5kW 29A SP32+�8 208V 3.OkW 14AA Sp ^^ -208 208V 4.1 kW 19.7A SP35 240V 3.5kW 14.6A SP55 240V 5.5kW 22.9A SP3271' 277V 3.OkW 10,8A SP4277 277V 41kW 14.8A OPTIONS PC = Flex Connector braided - stainless steel water connections available. (EX176, EX177) Example: SP3512FC Shopping Malls Office and Tenant Spaces Commercial Buildings (restaurants, etc.) Modular Buildings /Modular Offices Public Hand Washing Service Stations Schools Concessions Stands, Stadiums Designed to comply with .5 GPM handwashing code target outlet temperature 1050 - 110°. ADVANCED TECHNOLOGY e HIGHEST EFFICIENCY DESIGNED FOR DURABILITY ...._::u iHot :Vater no delay. paste -flow switch activates heater only on demand ino standby heat loss). 99 % efficient ho yvw':er - no storage capacity to run out. _stallzatio, , Cost - no T & P relief valve needed (check local codes). ,.:. .:.J� Or, -only one cold waterline need be brought, to :avatory - integral 3/s° compression fittings on ,op 01c sweat connections). Mounts on wall at point -of use :. .. esirctor - Built in to ensure proper temperature rise. Complies with U.S. Federal regulations. -with excellent spray pattern supplied with unit. :. :.._., _._a, sensor and metering faucet compatible MADE IN USA • Prevents i_egicnella Bacteria Growth • Reduces Liming, Calcification and Sedimentation. • Complies with Handicap Requirements • Ni Chrome Element - a unique, patented flow path ensures optimum heat transfer and extended element life. • Compact Size - dimensions 10.75"x 5.25"x 2.875"; weight 3 lbs. • Field Serviceable Element - replaceable cartridge element (1 year warranty). • Warranty - Full Factory Warranty - Heaters are guaranteed against failure due to leaks of "Heater Body /Element Assembly" for a period of FIVE YEARS. • High Temperature Limit Switch - protects against element burn out, with reset button.