Loading...
15120036CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: 15120036 7480 ROLLINGDELL DR CUPERTINO CA 95014 (359 31 061) GRAND - NEST. CONSTRUCTION SARATOGA, CA 95070 OWNER'S NAME: CHATTANATHAN GURUVAYURAPPAN AND GUR DATE ISSUED: 05/05/2016 OWNER'S PHONE: 408-506-6658 PHONE NO: (408) 891-8059 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class B Lic. #26541_9 - Contractor GRAND - NEST CONSTRUCTION Date 09/30/2017 —BLDG —ELECT —PLUMB MECH RESIDENTIAL COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: Construct one story addition (530 sq ft); Covered Porch (54 sq ft); add (5) I hereby affirm under penalty of perjury one of the following two declarations: lights in living room; relocate gas meter; upgrade electrical panel (200 r. I have and will maintain a certificate of consent to self -insure for Worker's amps). Compensation, as provided for by Section 3700 of the Labor Code, for the ,performance of the work for which this permit is issued. 2 j ' I -have and will maintain Worker's Compensation Insurance, as provided for by �'®® Section 3700 of the Labor Code, for the performance of the work for which this is issued. @�� permit Sq. Ft Floor Area: Valuation: $90000.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction, and hereby authorize 359 31 061 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. Signatures 6e Date Issued by: Abby A e�nde Date: 05/05/2016QS1OkiWh- OWNER-BUILDERDECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is following two reasons: 1. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sce.7044, Business & Professions Code) z I, as owner of the property, am exclusively contracting with licensed Signature of Applicant: contractors to construct the project (Sec.7044, Business & Professions Code). Date: I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER r. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the permit is issued. 3. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous shall not employ any person in any manner so as to become subject to the air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and exemption, I become subject to the Worker's Compensation provisions of the the Health & Safety Code, Sections 25505, 25533, and 25534. Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked.n Owner or authorized agent: APPLICANT CERTIFICATION Date: CONSTRUCTION LENDING AGENCY I certify that I have read this application and state that the above information is I hereby affirm that there is a construction lending agency for the performance correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city of work's for which this permit is issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, Lender's Address judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands ARCHITECT'S DECLARATION and will comply with all non -point source regulations per the Cupertino Municipal I understand my plans shall be used as public records. Code, Section 9.18. Licensed Signature Date Professional CONSTRUCTION PERMIT APPLICATION CONiI✓iUNI I Y DcVELO?MENT DEPAR I MEN I • BUILDING DIVISION 10300TORRE AVENUE * CUPERTINO, CA 85014-3255 r' (408) 777-3228 • FAX (408) 777-3333 • buildino(cicuneriino.ora cvt=ER-rtNo, i n i,7.w rnl ieTRlirT'in?S I/11 t �nrrn,.r 1-1 Bid.-App_2011.doc revised 06121/11 r P WE= ADDRESS V OtiNERNAMLE /{�(PHOh� L�O S O 6 fj I c-t✓_� IL G uKu GW\'PY N Ri !t �!/L �/vI GLYIi TL✓!/Y e A y 50 CD • S iRE_i ADDRESS t7 R p Lt. JN4 DEt L D QI CiTY, STATE, ZIP (_ V P IF -a7 1 ht 0 FAX COI, ACT STRZETADDRESS L/® CITY,ST4-'= Zip �r� )� ✓ r 12LOWNZER D, OR vTP,-BUIDER ❑ Oti `RACEnT CON—,—RAC—,OF, ❑ CO 7RACTORAGTT ARC?,= -.CT ❑ NG t'R ❑ bE}=LOPS ❑ iLhP.NT CONTRACTOR] AI✓B I LIC7 'SF-NU,—M I LiCEI ISE i i?B C V Yl I BUS. LIC CO]d3ATvYNA?W �-+ � / / r0 Y 04 C 6� 0• 06PIL9 — C o STREET ADDRESS M Y, STA n, Zi? P nolz d -%A' p� ARCHUF- 't E'YONEERNA?fr LICF.,NSE1\JTSrR 45 BUS. LIC CO?~;PANTY NAS E -?f IL I FAX STREET P.DDRF-SS I C -11 -Y, STAin, ZIP I PH01 t DESCRL'PTIO?,' OF 4JOP.iC 4 V ee 440e E aSTmG USE / PROPOSED USE CONST& TYPE � S i ORFS S !� T��// 1 I �i� I USE TYPS OCC. I SQ.FT. VALUATION (S) t .�''T AREA �G/ N;:W FIooR A,_9.FA , DE1,40 I AREA D TOTAL I "7 -AR: -:.k BATi721,OOM REMODELAREA® f:TCT.-LF?�T Pa,10DELAKE-A ® or REMODEL .42� I _ ' P TOT=L$ORC AREA 21TIACi® - "RrA �. IG'.GEP.=A: I D}1BL 'G J?diTS: IS A SECOND UNIT E3 YES - SECOND STORY ❑Yis - I BEING ADDED? 10N0 I ADDrrION? ..,10 '- OM TOTAL VA1 U.4 T ION: _ ' _ PP.E-?UPLICATMN ❑ }'_5 17 YES, PROTIDE COPY OF PLf�,?NTNG??P' R' L'-]�,.'0 PLA)\Th"D�GP.PPROVPT LT3 I IS THE BLDG AH } ES EICHLERHO?�i y�NO- �y�/� zo By my signature below, I c rift' to each of rhe following: I am tae property ow-ner or authonL dcg t to sct grope,. ou-n er's beh lr I hzv e � his - ��pp11c«Ion��Dd th..-norma�Ioa-I have:p;ovided is �ct:�I=h�we tl:e=Descrlp�io;r-of-'���ork '_ is -co, read and=w gat acct!rate I armee=�o`comply�,itti zll ��11cab: zl '"'- `� Coreirarces and state laws r 1ain+o builcln, co si2cr ?ze representatives to enter the zbow'e-1Ine +I�ed p op ry for inspection. pu.rps s _,.._.,.. . SUPPLE? /LE?�T� L _T0RI "r -MT REQUIRED - �_.CHT}'_P;E - _?\ew SFD or? ILlaiz ?ily dw� elii �� Apply for demoli`io� a "Iit for T Oi�RTCOL�TFR - — - Bi71LDL1GPL4tRtt7c Y exist?n- buiMinE(S). Deli Ol?tion peInit IS r1qui ed priorto '•SSllcnce Of building permit for new building. T7 -t- EYI2ESS _ — - - o PL�i'C�'L�GELeh,P.D4�F� Commercial Bldgs: Provide a completed Hazardous lwfaterials DisclosureESTE, _oma i_ any 1•iaZaroOLa ?Niater:a_s are bein. used as part ofthis project. - Copy of Planning Approval Le -tier or Iw/leeting with Planning prior to - T�L470R `��-�,TT.�tY-SE'w',ER�I�TRICT submittal Of Building Permit cppIlCitlGn.- .a _ Bid.-App_2011.doc revised 06121/11 r CITY OF CUPERTINO FEE ESTIMATOR - BUILDIN-G DIVISION ADDRESS: 7480 ROLLINGDELL DR DATE: 12/04/2015 REVIEWED BY: MELISSA - APN: 359 31 061 BP#: *VALUATION: 1$90,006 ''PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY SFD or Duplex USE: 2nd Unit? Yes Q No OTC. 0 Yes �No PENTAMATION 1 R3SFDADD PERMIT TYPE: WORK ADD 530 S.F. TO FRONT OF SFD TO CREATE N MASTER BEDROOM & N ENTRY WAY. ADD SCOPE (N) 54 S.F. COVERED PORCH & ADD 5 (N) RECESSED LIGHTS IN (E) LIVING RM TYPE OF FLR AREA OCCUPANCY TYPE: PC FEES PC FEE ID BP FEES BP FEE ID CONSTR. (sf.) R-3 (Custom) II-B,111-B,IV,V-B 584 $2,654.00 IR3PLNCK $1,666.00 IR3INSP TOTALS: 584 $2,654.00, $1,666.00 A Fc.,;"I ; � � � _.{E:.% Elec. Plan Check 0.0 1 hrs $0.00 Elec. Permit Fee: IEPERMIT Li L__ Other Elec. Insp. 0.0 hrs $48.00!Hwr,%?T r hap,,, - ::Ff'f; h. iY=.:s. NOTE. This estimate does not include fees due to other Departments (i. e. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc.). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for adan'l into. FEE ITEMS (Fee Resolution 11-053 g '. 7/1/13' FEE QTY/FEE MISC ITEMS Plan Check Fee: $2,654.00 5 # $72.00 Electrical IBREMFLU Fixtures, Lighting Suppl. PC Fee: O Reg. 0 OT 0,0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $1,666.00 Suppl. Insp. Feer Reg. 0 OTQ Q hrs $0.00 PME Unit Fee: $0.00 Permit Fee: $48.00 ggPME Work Without Permit? 0 Yes ;y No $0,00 Advanced PlanningFee. IPLLONGR $81.76 Select a Non -Residential Building or Structure Q Travel Documentation Fee: ITR,4VDOC $48.00 Strong Motion Fee: IBSEISMICR $11.70 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $4.00 sUBTOTALs; $4,513.46 $72.00 r TOTAL FEE $4,585.46 Revised: 10/01/2015 CITY OF CUPERTINO BUILDING PERMIT J 7480 ROLLINGDELL DR CUPERTINO CA95014(359 31061) OWNER'S NAME: CHATTANATHAN GURUVAYURAPPAN AND GUR OWNER'S PHONE: (408) 506-6658 LICENSED CONTRACTOR'S DECLARATION License Class GENERAL BUILDING CONTRACTOR Lic. #965419' Contractor GRANA -NEST CONSTRUCTION Date 09/30/2017 hereby affirm that I am licensed under the provisions of Chapter 9 (commencing rith Section 7000) of Division 3 of the Business & Professions Code and that my cense is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: 1. 1: have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the i performance of the work for which this permit is issued. (� I have and will maintain Worker's Compensation Insurance, as provided for by ((` Section 3700 of the Labor Code, for the performance of the work for which this v permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Date 10/512�Z1 I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 2. I as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: z. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. CONTRACTOR: PERMIT NO: 15120036 GRAND NEST CONSTRUCTION SARATOGA, CA 95070 DATE ISSUED: 05/05/2016 RHONE NO: (408) 891-8059 BUILDING PERMIT INFO: —BLDG —ELECT —PLUMB _ MECH _ RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION: Construct one story addition (530 sq ft); Covered Porch (54 sq ft); add (5) lights in living room; relocate gas meter; upgrade electrical panel (200 amps). REV #1 - PROVIDE STRUCTURAL CALCS FOR BAY WINDOW @ MASTER BEDROOM; CHANGE BATHROOM WINDOW -�rv) lo(sjtu Sq. Ft Floor Area: I Valuation: $90000.00 I" 3Number: Occupancy Type: APPLICANT CERTIFICATION i 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state haws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9,18. Signature Date 10/5/2016 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by: RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: 10/5/2016 "A" HA?ARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505, 25533, and 25534. Owner or authorized agent: Date: 10/512015 CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT •BUILDING DIVISION �.4 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 Mao (408) 777-3228 • FAX (408) 777-3333 • buildin4(o)cupertino.org CUPERTINO ❑ NEZ§r CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI REVISIO /DEFERRED ORIGINAL PERMIT;# 1 13) ZZIC PROJECT ADDRESS "7 ip & 0 R 0 L � % Na t>F LLD P APN n � � � � � � a 06 f "(- F (¢��QU ONVNER NAME PHONE ° ° , � � E-MAIL C4 C tA* --f `i A -J A-1 bra° j STREETADDRESS l P 0L�_R/4GD2_Li_ Pap_ CITY, STATE, FAX y�Q 67 �1� S�P CONTACT NAME PHON �E-NAIL ��� 48-9 v�7- 69-7 ZnRE���� cz�•-r STREET ADDRESS CITY, STATE, ZIP FAX El ow-NER ❑ OWNER-I3T,=ER ❑ OwIdERAGEN'r ❑ CONTRACTOR ❑ CONTRACTORAGEN'T 6irARCHrJECT ❑ ENGINEER 11 DEVELOPER ❑'TENANT LICENSENTUNME�R I LICENSE TYPE CONTRACTORNAME BUS. LIC' f� 3 6 IN J COMPANY NAIME E-h4AIL FAX P:P N D r4 r co Pa L? VF-- CD P'1 '181 6 d 9J STREET ADDRESS CITY, STATE, ZIP PHONE SID o A-RCHITECT/E*N-GITIEERN,Ah4E • LICENSEN 16BER BUS. LIC Ga1J COh2ANY NAME E -I ZAIL FAX STREET ADDRESS CITY, STATE, ZIP I PHONTE DESCRIPTION OF WORK t EXISTING USE PROPOSED USE - CONSTR TYPE - r STORIES - USE TYPE OCC, SQ.FT. VALUATION (S) EXIST NEW FLOOR DEMO - TOTAL. - AREA AREA AREA NET,AREA BATHROOM - KITCHEN OTHER REN4ODELAREA REMODELAREA REMODEL AREA PORCH ARTA - --DECK AREA TOTAL DECI:,'PORCH AREA �GAZAGE7JEA.�DETACH ❑ ATTACH D\�'ELLDdG UNITS: IS A SECOND UNIT ❑ YES SECOND, STORY ❑ PES - BELN•GADDED? NO ADDITION? ❑NTO PRE-.4PPLIC.ATION ❑ 1 -ES IF YES; PROVIDE COPY OF IS THE BLDG AN ❑ YES RE NED BY .y �` r �.� - TOTAL VALUATION: PLANNLNG APPL= ❑ NO PLAXINING APPROVAL LETTER EICHLER HOME? ❑ NO By my signature below, I certify to each of the following: I am the property owner or authorized agent tl act on , e property owner's behalf. I have read this application and the informationI have provided is correct. I.have read the Description ofWork- and verify it is accurate. I agree to comply with all applicable local ordinances and`state relating to building construction. I authorize representatives of Cupertino to enter the above -id tified prytpe ;ty for in- �ction purposes. / atureofApplicant/Age nt; /�P— CI_ate: ®Q SUP - _MENTAL INFORMATION REQUIRED r , -r PL�N..CA$CIi TI E New SFD or Multifamil} dwellings: Apply for demolition permit for � O\ ER TiIE COLTER k ❑ BUiLDI_ G PLA RE\TER existing building(s). Demolition pen -nit is required prior to issuance of building k �_ permit for new building. ELPREss PI ANSI_ 4vG PLAn Commercial Bldgs: Provide a completed Hazardous Materials Disclosure I� STA `D4RD ❑ PiBLIc.t\ oRl.s _ fonn if any Hazardous Materials are being used as part of this project. � LARGE � FIRE DEPT ` ,� Copy of Planning Approval Letter or Meeting with Planning prior t0 � � � S4�TTARYSE\iERDISTRICT � _ submittal of Building Permit application. \igJOR kr X... v. -..,..v-. :`... ..❑- EN\IR0N TENTAI HEALTH B1dgApp_2011.doc remised 06121111 CUPERTINO CALGREEN RESIDENTIAL CHECKLIST — MANDATORY ITEMS � - CUPERTINO COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING I� Building Department ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL ' 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 PURPOSE: (408) 777-3228 • FAX (408) 777-3333 • building aaeupertino.ora I. (")Q CODE COMPLIANCE The 2013 CalGreen Code applies to additions or alterations of existing residential buildings where the addition or alteration increases the building's conditioned area, volume, or size and also applies to all new low-rise residential buildings, high-rise residential buildings, or both. Existing site and landscaping improvements that are not otherwise disturbed are not subject to the requirements of CALGreen. Project Name: ::7y?2n 1201vJt-1c1a* '15 Project Address: Project Description Instructions: 7i�kal bio vMVr-��yw 1. The Owner or the n trr rey a experienced with the California Green Building S n Ftirlhe sfy't a urC)Puy work described herein is properly planned and impl `�` 2. The licensed professional, in collaboration with the owner and the design professional shall initial Column 2 of this checklist, sign and date Section 1 - Design Verification at the end of this checklist and have the checklist printed on the approved plans for the project. 3. Prior to final inspection by the Building Department, the licensed professional shall complete Column 3 and sign and date Section 2 - Implementati t tatil �tl i�d of this e[ckiis qr ut T), the completed form to the Building Inspector. 1 �L��,L11 VV C11.J� #2 ColuMiq 2 Column 3 MANDATORY FEATURE OR MEASURE Project Verification Reauirements Planning and Design - Site Development 4.106.2 Storm water drainage and retention during construction. A plan is developed and implemented to manage storm water drainage during El Elconstruction. 4.106.3 Grading and paving. The site shall be planned and developed to keep surface water away from buildings. Construction plans shall indicate how E] ❑ site grading or a drainage system will manage all surface water flows. Page 1 of 5 CalGreen 2014.doe remised 11/04/14 A4.2 ENERGY EFFICIENCY General 4.201.1 Low-rise residential buildings shall meet or exceed the minimum El design required by the California Energy Standards. A4.3 WATER EFFICIENCY ANDCONSERVATION Indoor Water Use 4.303.1 Water conserving plumbing fixtures and fittings. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the following: ❑ 4.303.1.3.2 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank -type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specifications for Tank -type Toilets. ❑ 4.303.1.3.2 Urinals. The effective flush volume of urinals shall not exceed 0.5 gallons per flush. ❑ 4.303.1.3.1 Single Showerheads. Showerheads shall have a maximum flow rate of not more than 2.0 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for showerheads. ❑ 4.303.1.3.2 Multiple Showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute at 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. ❑ 4.303.1.4.1 Residential lavatory faucets. The maximum flow rate of residential lavatory faucets shall not exceed 1.5 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. ❑ 4.303.1.3.2 Lavatory faucets in common and public use areas. The maximum flow rate of lavatory faucets installed in common and public use areas (outside of dwellings or sleeping units) in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. ❑ 4.303.1.4.3 Metering faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.25 gallons per cycle. ❑ 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. 4.303.2 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table 1401.1 of the California Plumbing Code. Page 2 of 5 CnlCreen_2014.doe revised 11104114 Outdoor Water Use 4.304.1 Irrigation controllers. Automatic irrigation systems installed at the time of final inspection shall be weather -based. ❑ 4.304.1.1 Controllers shall be weather- or soil moisture -based controllers that automatically adjust irrigation in response to changes in plants' needs as weather conditions change. ❑ ❑ ❑ 4.304.1.2 Weather -based controllers without integral rain sensors or communication systems that account for local rainfall shall have a separate wired or wireless rain sensor which connects or communicated with the controller(s). Soil moisture -based controllers are not required to have rain sensor input. A4.4 MATERIAL CONSERVATIONRESOURCE Enhanced Durability and Reduced Maintenance 4.406.1 Rodent proofing. Annular spaces around pipes, electric cables, conduits, or other openings in plates at exterior walls shall be protected ❑ ❑ against the passage of rodents by closing such openings with cement mortar, concrete masonry or similar method acceptable to the enforcing agency. Construction Waste Reduction, Disposal and Recycling 4.408.2 Construction waste management plan. Where a local jurisdiction does not have a construction and demolition waste management ordinance, a ❑ ❑ construction waste management plan shall be submitted for approval to the enforcing agency. Building Maintenance and Operation 4.410.1 Operation and maintenance manual. At the time of final inspection, an operation and maintenance manual shall be provided to the building ❑ ❑ occupant or owner. A4.5 ENVIRONMENTAL Fireplaces 4.503.1 General. Install only a direct -vent sealed -combustion gas or sealed ❑ ❑ wood -burning fireplace, or a sealed woodstove. i Pollutant Control 4.504.1 Covering of duct openings and protection of mechanical ❑ equipment during construction. Duct openings and other related air distribution component openings shall be covered during construction. 4.504.2.1 Adhesives, sealants and caulks. Adhesives, sealants and caulks 6,J ❑ shall be compliant with VOC and other toxic compound limits. 4.504.2.2 Paints and coatings. Paints, stains and other coatings shall be ❑ ❑ compliant with VOC limits. 4.504.2.3 Aerosol paints and coatings. Aerosol paints and other coatings shall be compliant with product weighted MIR Limits for ROC and other toxic ❑ ❑ compounds. Page 3 of 5 CalGreen_2014.doc revised 11104/14 4.504.2.4 Verification. Documentation shall be provided to verify that ❑ ❑ compliant VOC limit finish materials have been used. 4.504.3 Carpet Systems. Carpet and carpet systems shall be compliant with ❑ ❑ VOC limits. 4.504.4 Resilient flooring systems. Eighty (80) percent of floor area receiving resilient flooring shall comply with the VOC-emission limits defined in the Collaborative for High Performance Schools (CHPS) Low -emitting ❑ Materials List or be certified under the Resilient Floor Covering Institute (RCFI) FloorScore program. 4.504.5 Composite wood products. Particleboard, medium density fiberboard (MDF), and hardwood plywood used in interior finish systems shall ® ❑ comply with low formaldehyde emission standards. Interior Moisture Control 4.505.2 Concrete slab foundation. Required vapor retarders and capillary ❑ ❑ breaks are also required to comply with CalGreen Section 4.505.2.1. 4.505.3 Moisture content of building materials. Moisture content of building ❑ ❑ materials used in wall and floor framing is checked before enclosure. Indoor Air Quality and Exhaust 4.506.1 Bathroom exhaust fans. Exhaust fans which terminate outside the ❑ ❑ building are provided in every bathroom. Environmental Comfort 4.507.2. Duct systems are sized and designed and equipment is selected using the following methods: 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent. 3. Select heating and cooling equipment according to ACCA 36-S (Manual S) or equivalent. INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS Qualifications 702.1 Installer training. HVAC system installers are trained and certified in ❑ El proper installation of HVAC systems. 702.2 Special inspection. The Licensed Professional responsible to verify CALGreen compliance is qualified and able to demonstrate competence in the ❑ ❑ discipline they inspect and verify. Verifications 703.1 Documentation. Verification of compliance with CALGreen may include construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing ❑ agency which show substantial conformance. Implementation verification shall be submitted to the Building Department after implementation of all required measures and prior to final inspection approval. Page 4 of 5 CalGYeen 2014.doc revised 11/04/14 t' Project Name: Project Address: Project Description: CALGREEN SIGNATURE DECLARATIONS SECTION 1 - DESIGN VERIFICATION Complete all lines of Section 1 — "Design Verification" and submit the completed checklist (Columns 1 and 2) with the plans and building permit application to the Building Department. The owner and design professional responsible for compliance with CalGreen Standards have revised the plans and certify that the items checked above are hereby incorporated into the project plans and will be implemented into the project in accordance with the requirements set forth in the 2013 California Green Building Standards Code as adopted by the City of Cupertino. Owner's Signature Date Owner's Name ease Print) Design Professional's Signature Date Design Profess al's Name (Pjga-s.---Pr") Signature of License Professional responsible for CalGreen compliance Ddte Name of License Professional responsible for CalGreen compliance (Please Print) Phone Email Address for License Profelfsional responsible for CalGreen compliance SECTION 2 - IMPLEMENTATION VERIFICATION Complete, sign and submit the competed checklist, including column 3, together with all original signatures on Section 2 to the Building Department prior to Building Department final inspection. I have inspected the work and have received sufficient documentation to verify and certify that the project identified above was constructed in accordance with this Green Building Checklist and in accordance with the requirements of the 2013 California Green Building Standards Code as adopted by the City of Cupertino. Signature of License Professional responsible for CalGreen compliance Date Name of License Professional responsible for CalGreen compliance (Please Print) Phone Email Address for License Professional responsible for CalGreen compliance Page 5 of 5 CalGreen_2014.doc revised 11/04/14