B-2016-1752CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-1752 10225 CARMEN RD CUPERTINO, CA 95014-2758 (357 02 002) HIGHLIGHT SOLAR INC A CALIFORNIA CORPORATION SAN JOSE, CA 95117 1OWNER'SNAME: MCMILLIONMICHAELTRUSTEE&ET AL I IDATE ISSUED:04/13/2016 I OWNER'S PHONE: 408-504-3478 1 I PHONE NO: (408) 489-9273 I LICENSED CONTRACTOR'S DECLARATION License Class C-46 Lic. #960376 Contractor HIGHLIGHT SOLAR INC A CALIFORNIA CORPORATION Date 0413012017 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the erforinance of the work for which this permit is issued. 2. have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. .Std t�u"re � � Date 4/13/2016 I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not,intended or offered for sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations.per the Cupertino Municipal Code, Section 9.18. Signature Date 4/13/2016 BUILDING PERMIT INFO: X BLDG —ELECT —PLUMB _ MECH X RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION: INSTALL 24 (N)SOLAR PANELS 7.56 KW Sq. Ft Floor Area: l Valuation: $29500.00 APN Number: Occupancy Type: 357 02 002 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by: Abby Avende �nn Date: 04/13/2016 OBW G A IVA4W RE -ROOFS: All roofs shall be inspected prior to any roofing inaterial being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature ofApplicant: - Date: 4/13/2016 ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with tite Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Secti is 25505, 25533, and 25534. f {. ,�O - or authorized agent: I3.dte: 4/13/2016 CONSTRU TION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building (a,cugertino.orq PROJECT ADDRESS I Z 2 y^ (f % �� I APN R ()I_ 002 OWNER NAME MiG G MC LL, IPHONE4 D9 6'0 L3LI E-MAIL `L, f.7LtDm�. / ` STREET ADDRESS 10225 CITY,"r-'STATE, ZIP FAX �yhen �u Sao) � CONTACT NAME ` .�' PHONE t�L L �-C STREET ADDRESS � ` Par1�61b CITY, STATE, ZIVP �� G � -t FAX 6 J v � . ❑ OWN'P-R ❑ OWNER -BUILDER ❑ OWNER AGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHrIECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTORNAME MC� LICENSENUMBER ��(1` jp LICENSE TYPE BUS. LICA at COMPANY NAME E-MAIL ' FAX ' , L STREET ADDRESS CITY, STATE, IP 355 4 P�r�l I Ij PHONE W. +� /Fv� 0,i,CAelS lot ARCHITECT/ENGINEER NAME LICENSE NUMBER I BUS. LIC R COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF SFD or Duplex ❑ Multi -Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ NO FLOOD ZONE ❑ Yes ❑ NO SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTS (COMMERCIAL ONLY) r TOTAL VALUATION: DESCRIPTION OF WORK yRECEI\ ED BY t i ti k . By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I'h e read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to buildip/ construction. I authorize representatives of Cupertino to enter the above -identified property for inspection purposes. S ignature. of Applicant/Agent: Date: SUPPLEMENTAL IINIFORMATION REQUIRED FTCEU�E r- U� -❑� OVERTHUCOUT�TER rr_. o u{ r- ,. '� .❑� ST.'Ai�'DARD �. � ' `k �ry - }V t M ,on W Pi,.4pp_2011.doc revised 03116111 GENERAL NOTES 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. 5. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 6. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS VOER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY. 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WHITSANDING THE EXTRA WEIGHT. 9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERE N �Fnj ARTMEI� SHOWN, THE CONTRACTOR SHALL I�'Of��Fl�;i flLTRICCA,_ INO ENGINEER TO VALIDATE THE SIRE SIZE. FINAL DRAWINGS WILL BE RED -LINED AND UPDATED AS ;APPRPRIAT.E. 10. WHENEVER A DISCREPANCY INIQUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REC2UIREE BY THE STRICTEST CONDITIONS NOTED ON THE DRAWING'S'OR IN"THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND, LON.GEVITYOF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/EN,GI,NEE.R.S 11. ALL BROCHURES, OPERATION MANUALS;,CATAL'O'GS,`S'HO'F"' DRAWINGS, ETC. SHALL BE HANDED OVER TO OWNER'S �, c REPRESENTATIVE AT THE bb-WPtLETI=O='�_-FS_':' R _ _* D,, � - PHOTOVOLTAIC NOTES: PERMIT NO. 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTP CIRCUITS OVER 150V TO GROUND SHALL NOT Be ACCESSIBLE TO OTHER THAN QUALIFIED PERSZASI ' L ENERGIZED. 8. INVERTER IS EQUIPED W/ INTEGRATED GFDI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. CONDUITS SHOULD BE PAINTED TO MATCH EXISTING ROOF AND WALL COLORS 12. ALL WORK SHALL BE IN ACCORD WITH THE 2013 CBC, 2013 CEC AND 2011 NEC WITH SPECIAL ENPHASIS ON ARTICLE 690 13. THE OUTPUT OF A UTILITY INTERACTIVE -INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6) 14. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS AS PER NEC 690.47(C) AND SIZED AS PER SEC 250.122 15. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. 16. PER ART 250.92. NON -CURRENT CARRYING METAL PARTS I.OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. :.,;.-BOND BOTH ENDS OF RACEWAYS SHEET INDEX 1 1 1 ROOF PLAN I*:?r- :I T-STNUGLE LINE DIAGRAM Aw 3v"°" s CODE REQUIRED SIGNAGE 4 SITE PLAN, 5 ATTACHMENT LAYOUT 6 INVERTER DATA SHEET 7 MODULE DATA SHEET S MODULE CERTIFICATION 9 RACKING DATA SHEET 10 RACKING SPECS 11 ATTACHMENT DATA SHEET INSTALLER Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 Lic# 960376 Class C-46 DESIGNER NAME: DAVID D. DATE. 12 APRIL 2016 THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL BE IN ACCORDANCE WITH THE MOST RECENT CPC, CMC, 2013 CEC, 2013 CRC, 2013 CBC AND 2011 NEC. AS AMMENDED BY THE LOCAL AHJ. STRUCTUAL CONNECTIONS SHALL BE TO 2013 IBC. PHOTOVOLTAIC SYSTEM SUMMARY SYSTEM SIZE: DC STC: 7.56 KW SYSTEM SIZE: AC CEC 6.66 KW SOLAR MODULES: (24) LG SOLAR LG315N1C-G4 MICROINVERTERS:(24) M250-60-2LL-S2X MOUNTING SYSTEM: DUAL RACK ELECTRICAL INFORMATION: MAIN SERVICE PANEL BUS SIZE: MAIN SERVICE BREAKER SIZE: 20 BUILDING INFORMATION: ONE STORY HOUSE CONSTRUCTION TYPE: V-B OCCUPANCY: R ROOF: ASPHALT SHINGLE TRUSSE$ Q 2 CI _6 ewilding Depa b-nel kl PROJECT NAME: Michael McMillion PLOT LANE ECKED COY �I 1A1 _ 10225 Carmen Rd, Cupertino, CA 95014 ��„�,�,nr�� ��l �;®� �� �t �_� ���E VICINITY MAP SCALEATS SATELLITE VIEW SCALE:NTS STREET VIEW SCALE:NTS PHOTOVOLTAIC ARRAY (24) LG Electronics 315 W Solar Modules (LG315N1 C-G4) (24) Enphase Energy (M250-60-2LL-S2X) MATERIAL LIST TABLE Module: x 24 LG315N1 C-G4 Microinverter : x 24 M250-60-2LL-S2X Rail : x 19 168" Dual Rack Rails Attachment: x 80 Dual Rack Flashed L-Kit Ground Lug : x 48 Dual Rack Ground Lugs End Clamp : x 24 Dual Rack End Clamps Mid Clamp: x 36 Dual Rack Mid Clamps Channel Strut: 24 Enphase Trunk Cable: x 24 Monitoring Gateway: x 1 2 1.GROUNDING MID CLUMP (M8 REC. TORQUE 10FT-LBS) 2.END CLAMP (M8 REC. TORQUE 10 FT-LBS) 3.DUAL RACK RAIL ISTkNDARD,LITE OR HEAVY RAIL) *GROUNDING LUG 3/8 " BOLT TO MODULES OR RAILS (REC.TORQUE 10 FT-LBS) 3/8 " BOLT TO EGC (REC.TORQUE 5 FT-LBS) 4.ONE LUG AT THE 1ST MODULE ONE LUG AT THE LAST MODULE 5.ONE LUG BETWEEN TWO SPLICES OF RAILS 6.ONE LUG AT THE END OF THE RAIL TO GO TO THE J-BOX 7. #6 BARE COPPER EGC 8.PV MODULES GROUNDING AND CLAMPING DETAIL UL 2703 AND UL467 CERTIFIED FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 3 1/2" HEIGHT, THEN UNDER THE EAVE TO MAIN SERVICE PANEL UNIT INDEX MSP (E) 200A Main Service Panel J/B (N) Junction Box M250 Micro Inverter Solar Module EMT Type Conduit (C"PCE 1361161ng 09 r" N 0° W E 270° 90° S 180° SCALE 01 5 10ft General Notes ROOF PLAN Drawn By: David D. No. Revision/Issue Date CONTRACTOR nme...•, _ Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 Lic# 960376 ant �``Hig.hllig t Solar o a.J.* em • ,*— Michael McMil/ion 10225 Carmen Rd, Cupertino, CA 95014 oat. April 12, 2016 sod. AS INDICATED PV SYSTEM NOTE: A continuity of equipment grounding shall be provided with a minimum of #6 AWG copper grounding conductor between rail interconnection, and rail end connection with UL Listed Lay -In lugs (See Spec sheet on page #10) PV ARRAY1 % B CIRCUIT a i Boxi 9 LG ELECTRONICS —❑+ —❑+ —❑+ —❑+ NEMY6" Y 6"BY6" AC.2 315 WATT MODULES, I I 9 ENPHASE /� \'��/=\y� /� i ( 3/4" EMT CONDUIT/ MICROINVERTERS S 50 FEET PV ARRAY2 — — I J Box2 B CIRCUIT b —❑+ —❑+ —❑+ —❑+ NEMA 3R V 6"BY6" _ 15 LG ELECTRONICS 315 WATT MODULES, 15 ENPHASE M250 1z MICROINVERTERS #6 AWG EGC GROUNDING MID CLAMP PV ARRAY INFORMATION 24 LG ELECTRONICS 315WATT SOLAR MODULES MODEL # LG315N1 C-G4 24 ENPHASE M250 MICROINVERTERS MODEL # M250-60-2LL-S2X NUMBER OF BRANCH CIRCUITS: 2 NUMBER OF MODULES IN BRANCH CIRCUIT a: 9 NUMBER OF MODULES IN BRANCH CIRCUIT b: 15 MAX WATTS STC: 15 * 315W = 4875W PV MODULE RATINGS # STC SHORT CIRCUIT CURRENT I -SC = 10.02A MAXIMUM POWER CURRENT I -MP = 9.50A OPEN CIRCUIT VOLTAGE V-OC = 40.6V MAXIMUM POWER VOLTAGE V-MP = 33.2V .INVERTER RATING PEAK PWR TRACKING VOLTAGE = 27-39 V CEC EFFICIENCY = 96.5 % ENCLOSURE: NEMA6 MAXIMUM INPUT CURRENT = 10 A MAXIMUM OUTPUT CURRENT = 1.0 A MAXIMUM INPUT POWER = 210 - 300 W MAXIMUM OUTPUT POWER = 250 W [ ACA ] FROM PV MODULES TO J-BOX (3) ENPHASE TRUNK CABLE #12 AWG, PV WIRE + (1) #6 AWG BARE CU EGC FREE IN THE AIR [ AC.2 ] FROM J-BOX1 TO J-BOX2 (3) #10 AWG THWN-2 + (1) #8 AWG CU EGC, 3/4" EMT TYPE CONDUIT, 50 FEET [ AC.3 ] FROM J-BOX2 TO MAIN SERVICE PANEL (6) #10 AWG THWN-2 + (1) #8 AWG CU EGC, 3/4" EMT TYPE CONDUIT, 45 FEET # OF MICROINVERTERS IN BRANCH CIRCUIT a: 9 EACH INVERTER OUTPUT MAX CURRENT: 1.0 A BRANCH CIRCUIT CURRENT: 9 * 1.0 *1.25 = 11.2 A BREAKER SIZE PER B. CRCT - 15A # OF MICROINVERTERS IN BRANCH CIRCUIT b: 15 EACH INVERTER OUTPUT MAX CURRENT: 1.0 A BRANCH CIRCUIT CURRENT: 15 * 1.0 *1.25 = 18.8 A BREAKER SIZE PER B. CRCT - 20A MAXIMUM CONTINUOUS CURRENT: 18.8 A All the photovoltaic systems wires that on the roof and side of the building shall be protected against physical damage RACEWAY HEIGHT FROM THE ROOF 3 2" (TEMP - 39 + 17 = 56C) TEMP. DERATE FACTOR - 18.8 A 10.71 = 26.5 A MORE THAN 3 CCC ADJST. FACTOR (6 WIRES) - 0.8 ADJUSTED CONDUCTOR AMPACITY - 26.5 10.8 = 33.1 A WIRE SIZE FROM NEC TABLE 310.15(b)16 - 10 AWG AMBIENT TEM FACTOR 0.71 PER NEC 310.15(b)(2)(a) AC. 3/4" EMT CONDUIT 45 FEET MAIN PANEL RATING 200A TOP INSTALL 2P 15A CB(PV) AT OPPOSITE END OF BUS FROM MAIN FEEDER CB INSTALL 2P 20A CB(PV) AT OPPOSITE END OF BUS FROM MAIN FEEDER CB EXISTING GROUND ROD UTILITY M r� N METER EXISTING 200A MAIN SERVICE PANEL 120/240V 1 P,3W, #3/0 AWG rot r EXISTING SPLIT PHASE: 3W, 120/240V BUSBAR RATING = 200A MAIN SERVICE BREAKER = 200A TOPFEED 120% RULE: MAX ALLOWED FEED: 240A PV BACKFEED BREAKER SIZE: 20A + 15A ACTUAL FEED: 200 "MSP" + 35 A "SOLAR" = 235 A <= 240A MAX OUTPUT CALCULATIONS PV SYSTEM MAX DC OUTPUT: 24 * 315W = 7560W PV SYSTEM MAX AC OUTPUT: (24) LG315N1 C-G4 (24) M250-60-2LL-S2X Pmax (PTC Rating) PER MODULE: 287AW 287AW * 24 = 6.89 KW 6.89 KW * 96.5% CEC INVERTER = 6.66KW General Notes SINGLE LINE DIAGRAM Drawn By: David D. No. Revision/Issue Date CONTRACTOR Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 Lid# 960376 X of l` Michael McMillion 10225 Carmen Rd, Cupertino, CA 95014 not. April 12, 2016 S.A 2 AS INDICATED PV SYSTEM O O (STICKER TO BE LOCATED ON CONDUIT WITH DC CURRENT EVERY 4' HORIZONTALLY OR 10' VERTICALLY AND 1' FROM EACH SIDE OF A BEND) H O (TO BE LOCATED ON SUB -PANEL ONLY WHEN SUB -PANEL IS DEDICATED FOR PV ONLY) N 01 (i1 (STICKER LOCATED INSIDE PANEL NEXT TO SOLAR BREAKER) (STICKER LOCATED INSIDE PANEL BELOW PV BREAKER) (STICKER LOCATED ON THE PV SUB PANEL) Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipmenq or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacemet, exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). Plaques will have red background & white lettering. MARKINGS, LABELS AND WIRING SIGNS A. Purpose: Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system. This can facilitate identifying energized electrical lines that connect solar panels to the inverter, as these should not be cut when venting for smoke removal B. Main Service Disconnect. 1. Residential buildings - The marking main be placed within the main service disconnect. The marking shall be placed — A outside cover if the main service disconnect is operable with the;servicptpaR I :...;;. 3 closed. T .zrx 2. Commercial buildings - Tha marking shall be placed adjacent tdtin; service disconnect clearly visible from the location where the levdl'li,o'perated+ 3. Markings: Verbiage, Format and Type of Material. a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNEGTED`'`� b. Format: White lettering on a red background. Minimum 3/8 inches letter height. All letters shall be capitalized. Arial or similar font, non bold.�1F�!!�`�R�C c. Material: Reflective, weather resistant material suitable for the enVi lament (use UL - 969 as standard for weather rating). Durable adhesive materialsgUqeBv: this requirement. C.Marking Requirements on DC conduit, raceways, enclosures, cable assemblies, DC combiners and junction boxes: 1. Markings: Verbiage, Format and Type of Material. a. Placement : Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, at turns, above and for below penetrations, all DC combiners and junction boxes b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material shall adhere to "V. V-3b, c" of this requirement. c. Inverters are not required to have caution markings 1.Marking is required on all interior and exterior DC conduit raceways,enclosu res, cable assemblies,and junction boxes,combiner boxes and disconnects.CFC 605.11.1 2.The materials used for marking shall be reflective,weather resistant material suitable for the environment. Minimum 3/8 "letter height; all upper case letters Aria[ or similar font; Red background with white lettering. CFC 605.11.1.1 3.Marcking shall contain the words: WARNING: PHOTOVOLTAIC POWER SOURCE. CFC 605.11.1.2 4.Marcking shall be placed adjacent to the main service disconnect in a location clearly visible from the location where the disconnect is operated CFC 605.11.1.3 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH PV EQUIPMENT LOCATED AS SHOWN: SERVICE POINT & UTILITY METERING 0 SOLAR PV ARRAY WITH n MICROINVERTERS ON ROOF a ❑ 0 11 SOLAR PV ARRAY WITH MICROINVERTERS ON ROOF "® INVERTER TYPE: MICRO .. General Notes CODE REQUIRED SIGNAGE Drawn By: David D. Department Building 0CE No. Revision/laaue Date CONTRACTOR ■..ate Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 Lic# 960376 X Michael McMi//ion 10225 Carmen Rd, Cupertino, CA 95014 April 12, 2016 a.. 3 sad. AS INDICATED PV SYSTEM UNIT INDEX o° MSP (E) 200A Main Service Panel SITE PLAN FLASH MOUNTING DETAIL MODULE WEIGHT (Ibs) 37.5 # OF MODULES 24 TOTAL MODULE WEIGHT (Ibs) 900 RACK WEIGHT (Ibs) 180 MICROINVERTERS WEIGHT (Ibs) 106 TOTAL SYSTEM WEIGHT (Ibs) 1186 # OF STANDOFFS 80 MAX SPAN BETWEEN STANDOFFS (in) 48 LOADING PER STANDOFF (Ibs) 14.8 TOTAL AREA (sq.ft.) 432 LOADING (PSF) 2.74 1. Dual Rack Racking System 2. Dual Flashed L-Kit Attachment 3. Racking loading calculations were performed for ASCE 7-10 wind speeds @ 110 mph for B and C exposure categories and ASCE 7-10 Seismic Design Category E. 4. Roof attachment hardware to be mounted to existing structure (2"x8"@24" O.C. Trusses) at 48" O.C. rail spans or less. 5. Lag bolts are 5/16" X 3.5" stainless steel with 2.5" minimum embedment into the roof rafters. 6. Roof sheathed with 1/2" plywood and upper surface is faced with felt paper. Finished roof surface is Asphalt Shingle. 7. Mounts or/and mounting hardware will be sealed with Tremco Vulkem 116 Polyurethane Sealant or equivalent. ocking ind Brace am r�af��fEE y DUAL RACK FLASHED L-KIT ATTACHMENT DUAL RACK RAIL EXISTING 2" BY 8" @24" O.C. ROOF TRUSSES UP General Notas ATTACHMENT LAYOUT Drawn By: David D. No. Revision/Issue Date CONTRACTOR Highlight Solar Inc. Ad d ress : 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 Lic# 960376 X a, H j.d N.. 4 A*— Michae/ McMi//ion 10225 Carmen Rd, Cupertino, CA 95014 Dm, April 12, 2016 5 sue. AS INDICATED PV SYSTEM Enphase', Microinverters Enphaseq,M250 r 6 The Enphase' M250 Microinverter delivers increased energy harvest and reduces design and installation complexity with its all -AC approach. With the M250, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M250 integrates seamlessly with the Engage Cable, the Envoy' Communications Gateway'"', and Enlighten', Enphase's monitoring and analysis software. p r nT: �UlEdlrt✓ �e�,�Itl�rGt Ly®1�;�i'� 9�5� Enphasel!l M250 Microinverter // DATA INPUT,DAU (DC) M250-60-2LL-S22/S23/S24 Recommended input power (STC) 210 - 300 W Maximum input DC voltage 48 V Peak power tracking voltage 27 V - 39 V 'Operating range 16 V - 48 V Min/Max start voltage 22 V / 48 V Max DC short circuit current 15 A Max inpu[ current 10 A OUTPUT DATA (AC) @208 VAC @240 VAC Peak otltput. power 250 W 250 W Rated (continuous) output power 240 W 240 W Nominal output current 1.15 A (A rms at nominal duration) 1.0 A (A rms at nominal duration) ` Nominal voltage/range 208 V / 183-229 V 240 V / 211-264 V Norninal frequency/range 60.0 / 57-61 f Iz 60.0 / 57-61 Flz Extended frequency range" 57-62.5 Hz 57-62.5 Hz Power factor >0.95 > 0.95 Maiiimum units per 20 A branch circuit 24 (three phase) 16 (single phase) Maximum output fault current 850 mA rms for 6 cycles- 850.mA rms for 6 cycles ' EFFICIENCY CEC weighted.efficiency, 240 VAC 96.5% CEC weighted efficiency, 208" VAC 96.0% Peak inverter efficiency 96.5% Static MPPT efficiency (weighted, reference EN50530) 99.4 % Night time power consumption MECHANICAL DATA 65 mW max Ambient temperature range -4&C to +65°C Operating temperature range (internal) -400C to +85°C Dimensions (WxHxD) 171 mm x 173 mm r. 30 mm (without mounting bracket) Weight 2.0 kg Cooling Natural convection - No fans Enclosure environmental rating Outdoor - NEMA 6 FEATURES Compatibility Compatible with 60-cell PV modules. PRODUCTIVE SIMPLE RELIABLE Communication Power line - OptirYtized`for higher -power No GEC needed for aiicroinverter - 4th-generation product Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in modules No DC.design or string calculation More than 1 million hours of'testing NEC.690.35. Equipment ground is provided in the Engage Cable. No - Maximizes energy production reciuired and millions of units shipped additional GEC or ground is required. Ground fault protection (GFP) is integrated into th ,microinverter. -,Minimizes impact of shading, Easy installation with Engage - Industry -leading warranty, up to 25 Monitoring Free lifetime monitoring via Enlighten software dust, and debris Cable years Compliance UL1741/IEEE1547, FCC Part 15 Class B, CAN/CSA-C22.2 NO. 0-M91,. '0.4-04, and 107.1-01 ' Frequency ranges can berextended beyond nominal it required by the utility [9,1 enphase, ® C To learn more about Enphase Microinverter technology, 1enphase- J E N E R D 1 J E N E R G Y C US visit enphase.com 0 2013 Enphase Energy. Nl.rights.re ervcd.:Vl tndemvlcs or brands in this docurfient are registered by thcr rcspectwe o'dmer. General Notes INVERTER DATA SHEET Drawn By: David D. No. Revision/Issue Date CONTRACTOR Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 Lic# 960376 X wgea r.. • ,&— Michael McMil/ion 10225 Carmen Rd, Cupertino, CA 95014 Dee. April 12, 2016 a.a 6 Sow AS INDICATED RM� PV SYSTEM LG Life's Good LG's ne:v module, LG NeONT" 2, adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires to enhance output and reliability. LG NeONTI 2 V AP"rROVEO PRODUCT power 60 cell demonstrates LG's efforts to increase customer's values D E c ua p beyond efficiency. It features enhanced warranty, durability, InteRek isrr�s,21s performance under real environment, and aesthetic rawtsra P tin m m'Ja design suitable for roofs. 111111� Enhanced Performance WarrantyHigh III II� g Power Output i�►,i;;i;i� LG NEON' 2 has an enhanced performance warranty. g Compared with previous models, the L.G NeON" 2 �IIiI` The annual degradation has fallen from -0. ` elyr to has been designed to significantly enhance its output �11111}}I}Il4 -0.6° •;yr. Even aft_ i 25 years, the cell euarancees 24%p efficiency, thereby making it efficient even in limited.space. more output than the previous LG NeONTh1 modules. c: h Aesthetic Roof di —will Outstanding Durability @itltl MUMS LG NEON' 2 has been designed with aesthetics in mind; clogi:ec:ee�e trvith its newly reinforced frame desir_.q LG has attended. Eo10' EIECBo= thinner mires thatappearall black at a distance. -5loot".INHHo3 the warranty' of the LG NEON" 2 for an additional __ -- The product may help increase the value of �i"`"r'1r°- 2 Yeats. Additionally, LG NeON- 2 can endure.a front a property. with its modern design. load up to 6boo Pa, and a rear load up to S400 Pa. h�� a Better Performance on a Sunny Dayi Double -sided Celt Structure a�€aoi, asE LG NEON— 2 now performs better on sunny days thanks s�iiixtr � The rear of the bEtl used in LG NeON­ 2 will contribute to iaeteee€see 4a Eza... •Fi to its improved temperature crrefficiency. e t�€�=4 ir18� geiieration,justliketh front; the light beam reflected from ldlulumip ref-=� P31L L'.-i:% the rear of the module is reab:orbed.to generate agreat amount of additional power. Abeet LG Electronics LG. E(ect-onics i.. ) .i•.I r:Ayer Mho has tMPn r'+'iaavcicn eMpandlo Jts-paclty, based on solar e x9y bu:irez as its firzurP growth entire. We. embarked on a :olsr nr my soLa;e :eseerch. program to 1985 supported by Wrraup's rich experience In semi-mnrluct*•t LED chem(stry and materials Industry We successfully released the first Mono Xs series to the market In 20iO w1iIch %ere WOrted 1032 co•_noin in he r: Ilet°an3 2 years, the rafter In 2G13. LG WON (p ,,., r p ki,6, in as ),Ir . X- *OK) Aron "Inre olar Avami', whichprn%�ed LG is r.v It &r of ionovation ir, th. nt:iisriy Mechanical Properties Cells 6 x 10 Celt Vendor LG Celt Type Monoaystalliine % N-type Cell Dimensions 156.75 x 15b:75 mm 16 inches u of Bulbar 12 iMuld %N.re 6us1w.r) + ` Dimensions (L x W x H) 1640 x 1000 x =.0 nun 6457 x 39.37 x 1.57 inch Front Load 6000 Pall 25 psf Rear Load 5400 Pa! 1 13 psf 4* —..--�_. -------- Weight --._........... — 17.0 t- 0.5 kg / 37.48 t 1.1 Ibs Cnnn—wrlype •1C4, 1ACd Comparble, IP67 Junction Box IP67 with 3 Bypas, Diodes Length of Ce:,tes Glass ------------------- 2 x 1000 mm / 2 x 39.37 indi -- Hign Transmission tempered Glass Frame Anodized Alurn njin Certifications and Warranty Certifications IEC 61215, iEC 61730-1 /-2 IEC 61_7'16 (Anvnonia Test) IEC 6170 1 (Salt w1Lt, Coro-sion'T6,;Q GO 9001 - - UL Module. Fire Performance (USA) Type 2 (LIL 1 iO3) Fire Ratin (for CANADA) Class C(_ILC;ORD C1703) Product warranty 12 years Output Warranty or Pmax Linear warranty` ^ Ii IKWA _r i _ _. s xi_N.%3)53.6% Temperature. Characteristics rdOCT 46 = 3'C _Voc_ -0,22 `o/'C Ise ..__------------- G.034=;"C---------- --- Characteristic Curves � E.M F.netV eM eom:J !OS 'JC:Y I00:V oco sac ,cite ',sx ?i:ro :sco a�a as.c> >a.x aso; OLG N;.rthA ,ca Sui..r Bu ne sTe<m LG.Etcctroc-L5:11 - Clfe's Goa 1 Cii C SyIa Ave Engler,eod Cli'r-, NJ 0753'_ f 5 I AIA n. r 1,J P m Eq vrww.g,cia� usacom Lj-1 tJ Electr teg r%R\4i9s (STC�*) Module Type -ri MPP' aLaw�VQ) 33.2� MPP CUT tent '(Irnpp) 9,50 Open Circuit Voltage (Voc) 40.6 Short Circuit Current(lsc) 10.02 Module Efficiency (%) 19.2 Operating Temperature (°C) -40 -+90 Maximum System Voltage (V) 1000 Maximum Series Fuse Rating (A) 20 .—.__.._..------......_.......... _.... --..... ------------.__._ Power Tolerance.(%) 0- t-' 'The typl.1 duvnve In ud,le a„s r y. 200 W1m inreiamn to 1GOO W,'If is -ZOK Electrical Properties (NOCT*) Module Type 315 LN Maximum Power. (Prnm) 230 MPP Voltage (Vmpp) 30.4 N1PP Current (tmpp) 7.58 Open Circuit Voltage (Voc) 37.E Short Circuit Current (isc) 6.08 'JVOCTit4ore,x1 Jpceng:C61 R,7p>,aun1I:..6-:e 50C 7.'irh'.—t;ur,-e;vI,aw,r 20'i,•Mrd epc: d 1!r.:c Dimensions (mm/in) I� C, I I I i � c�' r,<tEaambr:c:cezV.. :terott`'e Pmdu-tspeunutiorn are suLjectto ctwnge v.•itho,c� notice D5442bD C -F-EN - 504 :7 Copyright V 1-01 S. G nectronia, All .Hghts reservod av •oe M r •I5 Innovation fora Better Lire A q r General Notes MODULE DATA SHEET Drawn By: David D. No. Revision/Issue Date CONTRACTOR rtm, rn A clew Highlight Solar Inc. Add ress: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866)926-9997 Lic# 960376 X Michael McMillion 10225 Carmen Rd, Cupertino, CA 95014 Dora April 12, 2016 1.A 7 sods AS INDICATED P-W PV SYSTEM AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the, conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified 'on the correlation page of'the Listing Report,. This document is the. property of Intertek. Testing Services and is not transferable. The certification marks) may be applied only at the location of the Party:Authodzed To Apply Mark Applicant:, LIG Electronics Inc. 168, Such6I-daero, Solar,Biisiness Division (Solar Factbry),.Gurni-si; Address: Gyeongsangbuk-rib 730-903i Republic of Korea Country: Republic of Korea Contact: Mr. Jeon,gwon Choi' Phone: +82-54-4690386 FAX: +82-5:4-4607931 Email: jeongwon7.choi@lge-.cam Manufacturer: LG Electronics Inc. 168, Suchul-daero; Solar Business Division: (Solar Factory); .Gumi-si, Address: Gyeongsangbuk-do 730=903, Republic of Korea Country: Republic of Rorea Contact; Mr- Jeongwon Choi Phone: +82-54-4690386 FAX: +82-54-4607931 Email: jeongwon7.choi@lge.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing'Office: Infertek Testing Services Shanghai Control Number: 5000343 Authorized by Thomas J. Patt'e M, COrtificatjd4i Manager I To US i Interteki This document,supersedes all previous Authorizations to Mark for the noted Report Number. This Auf dzation to Mark is [or the exclusive use of Inlertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility -and liability are limited to the terms and conditions of the, agreement. Intertek assurnes no liability to any party, other than IU the Client In accordance with the agreement, for any loss, expense or damageoccasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying ordistribetlon ofthis Authorization to Mark. and then only In its entirety., Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark..Any further use'of the Intertek name for the sale or advertisement of the tested material, product or service must lirsl be approved in writing by Intertek. Initial Factory Assessments and Follow up.Seivims are for the purpose of assuring appropriate usage of Me Certification mark in accordance with the agreement, they are nolfq the purposes ofpruduction quality wntiol and donet relieve the Client of lheirobtigations in this respect. Intertek.Testing"Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 8007345-3851 or 847-439-5667 Fax 312-283-1672 UL 1703 2002/03/15 Ed:3 Rev:2014/11118 Standard(s): UL Standard for Safety Flat -Plate Photovoltaic'Modules and Panels Product: Crystalline.Silicoh Photovoltaic modules Brand Name: ' L EleIct, onics LGxxxN1.C-G4 ('xxx' is the number from 28p to 340, in step of 5j, LGxxxN1W-G4 (xxx'.is the numberfrom 280 to 340, in step'of 5), Models, LGxxx81.C-G4 ('xxx''is the number from 250 to 300, in step of 5), LGxyxS1 W G4 ('xxx' is the number from 250 to 300, in step of 5), LG)=N1 K-G4 ,('xxx' is the number from 280 to 330, in step of 5). ATM for Report 1150201020SHA, 001 'Page `1-of'l ATM Issued: 28-Apr-2015 ED16:3,15 (1Jen-13) Mandatory" I r� �O .14aT Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com In the basls..of the tests undertaken,athe sample(s) of the below product -have been found to;complywith the requirements of the;refer6nced specifications at the 'time _the testsaivere carried`out_ Applicant Name &.Address: Dual. RackInc. 241N. '10" St.,Unit4 Sacramento, CA 9581:1 USA . Product Description: Flush mount photovoltaic rack., Ratings & Principle ,Fi-re'Class Resistance Rating: -Characteristic's. -Class A Fire Rated for Steep Slope applications when using Type 2, listed photovoltaic modules: System.tested with a 5" gap'(distance-between the bottomthe module frame<and the roof covering); per the U.L 1703 standard this system can. be installed at any gap.allowed by the ' _- °tnanufacturersinstallattion instructions. Installationperper the manufacturer's_installation . instructions: No;petimeter guarding is required. Wind skirt`s`areoptional'. Models ,Brand Name: Relevant Standards: Verification issuing Officer Date of Tests: Dua(Rail PV. Racking,System Fortune Energy Dual Rail ,. UL Subject,2703 (Section 15.2 and 153) Outline of Investigation for Rack. Mounting Systems, and Clamping Devices ,for Fiat -,fate Photovoltaic Modules and Panels, First Edition, January 28, 2015 Referencing UL1703 Third Editibn(Section 31.2) Standard for Safe.ty;for Flat -Plate Photovoltaic Modules and Panels, Oct. 2015. Intertek Testing Services'I Inc. 8431 Murphy.Drive Middleton, WI 53562 10/07/,2015-10/27/2015 Test.Repoef Nurnbet(s): 1102283397MID-001 This.verification.is part of the full test report(s) and should be read in conjul imply producfcertification'. Completed by: Chris'Zimbrich Reviewed by: Title: Technician II, Fire Resistance Title: Signature: l� � i >Signature: Date: 10/30/201S Date: With them. I his report:aoes not au[omaticauy Gregory Allen EngineeringTeam Lead; Fire Resistance n , 10/30/20T5 This Verificc tion is for the exclusive use of.Intertek's client and is provided pursuant to the agreement between Intertek and Its Client. hitertek's responsibility and liobility are krnitcd�to, the terms and'conditions of the agreement. Wertek assumes no liability, to any por ty, other thonto the Clienbin.accordpnce :vith the agreement, for any loss, exrpgnse oriinmage,orc-ns9orted fry the use of this Veiilication. Qnly the Client is nuthorrzed to perrniI copying or distribution of this Ve il-ication. Any use:of the intertek name crone vriLs marks for the sole oradverriscmentof the tested material, product or service mcstfirst beapproved ,in writing by intertek. The observations and testlinspection results referenced "in this Verification are relevant only So the sample tested/inspected. This Ver!fcntion by.itself does not imp!y that the maferiaf, product orservice Is or has ever been under on lnte. II certification progrurn. 6FT-OP-11a (24-MAR-2014) General Notes MODULE & RACK CERTIFICATION Drawn By: David D. No. Revision/Issue Date CONTRACTOR Rm em. • A* — Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 Lic# 960376 X _z�Ei fr � igMig It Solar R.J nm. •Arlo Michael McMi//ion 10225 Carmen Rd, Cupertino, CA 95014 De. April 12, 2016 s.a 8 soak AS INDICATED Rkna PV SYSTEM Dual lack PV MOUNTING SYSTEMS DUAL RACK- 11111in , Dual Rack rails were designed to be customized for solar PV arrays on residential and commercial projects. They are engineered for strength and durability and tested for spans of up to eight feet. Installers prefer Dual Rack rails because they are strong, reliable, time saving, and available at the best price in the marketplace. ADVANTAGES A`1ET 11 Advanced.Dual Rack design 07 11 • PE.Certified in 16 states IITY N.o. a'78i 91 No special training required �� \ 11 • Save time and money on installations \ of CC • Less parts, two ways to install • 3 sizes available: 12', 14' & 11' - in silver & black • 10 year limited warranty • Conforms to UL STD 2703 and Class A Fire Rated EfL%§_ CCLLASSIFlm us Intertek a000799 Lont•rms to UL SUe 2703 TRIM Product Item # Product Name ST-144-C, Standard Rail 144' - Clear ST-168-C Standard Rail 168- - Clear ST-204-C 'Standard Rail 204' - Clear ST-144-B Standard Rail 144' - Black ST-168-B Standard Rail 16T -Black ST-204-B StandardRail 204' - Black `Ma`terial`S�ecificattons �w� _�_ ��_s�u_� Material Designation 6005 T5 Density (p) 168.56 Ibs1fi' (2.7 g/cm') Coefficient of Thermal expansion (a7) 1.306E 05/'F(2'.35E-05!°C) D ttusivity(X) 200A0 Wfm-'K Modulus of Elasticity (E) 10.152E06' Psi (7,000 kNlcros) Shear Modulus (G) 3.916E06 Psi (2,700 kN/cm') - Mechanical Properties _ _ _ _ � � �,. Tensile Strength:(f.a) 38.0 Ksi (26.0 kNlcm) Tensile Yield Strength (f yk) 35A Ksi (24.0 kNlcml) Profile Wall Thickness (t:5 0.39 in/100 mm) Section Pr,certies I: 0.383 in' V6 0.334 in- lY 0.206 in° Wr 0.262In' . A 0.581 in' Weight 6.68 lbs/it Standard 'Packaging 6 pcs Dimension 140168'/ 204" Weight 0.68 lbsIR Rail SPan':(ftl) EXP 8 Wind Speed (Mph): 110 I 120 1 130 140 1e0 �160 170 160 17o Zone _....._. _... _ - Snow Load (pA 0- 10.0 -2o.a X0 40.0 JSl16 8.0.... 7.0 6.0 5.0 4.5- 1 4.0 8 Ojy7.0 6.0 5.0" 4.5 I 4,0 8.0 L ;G 6.0, 5.0 4.5 .4.0 8.0 I TO 6.0 5.0 4.5. 4.0 7.5 TO 6:0 5.0 4.5 I 5 '7.0 - 7.0 6.0 .5.0 4.5 ! 4.0 7.0T 7,01 6`.0_ s:a ( _4,5'. I 4.0 6.5 0.5 i 5.5 5.0. ! 4.5 '�- 4.0 o 7 6 6.0 5,C 4.5 1 4.0 120 8.0 7.G 6.0 5.0 4.5 I 4.0 C _ 140 150 _7.0 Z.0 6.5 _ 6.0 _ _ 6.0 5.5 5.0 �5`.0 ; '5.0 _a.5_� 4.5 4.5 4.0 4A ( 4.0 too _6.S f.0 6,1) I 5.5 5,0 4.5 4.0 , 5,5 5.5 5.5 5.0 4,5' 4.0 180 5.5 5.5 5_5 5.0 A Tho IbNe'tcse ONLY t dud3 PU31 RX_A. @tl ca't icly n Nos MtjmLide 2x aRcWor, a My wpamrf -rgGK 6.w5nde.Ac teyuryiIWASCE710. C TcpN.Whicfacicr,l¢tis1.0. O Maanurtrnkan tiwlliMyht is 307_ E.Aua:neparepettxyMuO:L F.:tuclphhistrty 7dedree.'127deyr­ a: h'arJman sulErpa�l weFyht L9.50 Ds: H. Height d Solar ravel is between 2'-ana 10- to rcot .See-Zone,2,8 3 span. table calculation in,lnslallatlon ManuaL'P.E. ceA ficad6n. Dual lack Pi'- MOUNTING SYSTEMS Dual Rack -Standard Rail I:0 InsaIlatioYi e a Dual Rack is a robust, long -life photovoltaic (PV) module mounting system for both,flat and pitched roof. It consists of aluminum rails, roof attachments and all necessary small parts to ensure -a safe installation. Dual Rack allows modules to be mounted in both landscape and portrait orientations. • Dual Rack technology can be installed in two different ways: Top down attachment style and L-Footstyle TOP DOWN • Measure and mark location of each standoff to roof connection. • Drill 318' hole through Dual Rack standard rail for each.standoff location • Attach standoff to roof with 5116' lag screw. Attach Dual Rack. standard rail to standoff with 3/8' bolt and washer period. L-FOOT STYLE After securely installing standoff to rafter, attach L-foot with 3182 bolt and nut to Dual Rack standard rail at desired height Dual Rack L-foot enables height adjustment up to 1.1 inches. y.Contact Info � _'�: `Distr'Uutor Info �„ Dual Rack Inc. 241 N. 10th street, # 6.7 Sacramento, CA 95811 ' 916-492-2797 General Notes RACKING DATA SHEET Drawn By: David D. No. Revision/leeue We CONTRACTOR Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 Lic# 960376 x Ro}d Iles ! Aim Michael McMillion 10225 Carmen Rd, Cupertino, CA 95014 Me. April 12, 2016 3h t 9 sod. AS INDICATED PV SYSTEM 3wldiing DcPa�trner.` i-IT i �flL`ly`f` Dual lack t t - an 4R, fisio-7r.tf s"+ .tb Ylt3iu_.a_Racy vvMOLNT1NG SYSTEA19CV MOU\T1NG SYSTEMS lL C—`Rt sI �R sTf��ire tttr; 'atlNl vtyt' } i�eiesc�3✓ivSir,,:l GROUNDING LUG The Dual Rack GBS-P6 is a grounding bonding splice lug that is compatible with all solar racking systems and framed solar modules. The Dual Rack GBS-P6 is the first lug that is not only a grounding, it is also a grounding jumper as this can be installed at spliced section of railing. This will keep onsite inventory lower with the multipurpose lug that works to ground and bond solar PV modules and racking systems. With the Dual Rack GBS-P6 you will find only lower cost and faster installations with the only grounding bounding splice lug on the market to be UL467 certified and UL2703 recognized ADVANTAGES • Compatible with Dual Rack PV mounting system 41 Easy installation save time • Electrically bond the solar modules together • Mechanically clamp solar panels in place • Made from stainless steel 1.4301 • Lock -time bolt for secure attachments • Compatibale with 12-6 AWG Cu. • UL 467 Certified and UL2703 recognized En CLSSIRED Ua �o ProductLine v Ilerrdt Product Name DR,GBS-P6 DR Grounding Bonding Splice Lug Mafefiai Specifications _ _. = Material Designation Stainless steel 1.4301 Chemical Formula X5MH810 Hardness A2-70 Density (p) 493.2 lbr dft' (7.9 glcm') Coefficient of Thermal expansion'(q� 2.88E-051°F (1.60E-051-C) Diffusivity (A) 17.00 W/m-°K) Mddulus of Elasficity(E) 35.50E06 Ibr ff (17,000 kN16MI ShearModulus(G) _ 13.47E061bM?,(6,450kN/cm) Idatenal Grounding Lug 01 Back Plate 01 318' Hex Nut 01 °ETeetrtcal°°:` p� _. Voltage: Up to 1000V DC, 480VAC Short Term Current Test (UL 457) 6AWG 1530A(6 Seconds). pp>lication8 Solar panels and related photovoltaic products require groundng per the National Electric Code.(NEC Article 690.43). These applications include, but are not limited to electrical grounding of solar modules and roof tiles GROUNDING MID CI.AlAMP Product Line�__.__a Item # Proclu^t Name DR-GMC-01 DR Grounding Mid Clamp gate4Specifications.-;Grounding Mid Clanip�. Material Designation Stainless steel 1.4301- Alloy X5CrNH810 Hardness A2-70 Density (p) 6.29 Ibm/in' (7,9&nfl Coefficient of Thermal expansion (a) 8:9E-06/`F(1.60E-051-C) Modulus of Elasticity (E) 24,677.4 KipAr � (17,000 kN/cm`) Shear Modulus (G) 9,362.9_ Kip[W(6,450.00 kN/cm� 1Vlatcrial Specificahons�Channel Str.,iit e w Material Designation 6005=T5 Density (0) 168.56 Ibs/fe (2.7 glom') Coefficient of Thermal expansion (a) 1,306E-051-F(2.35E-051°C) Diffusivity (A) 200.00 W/m-°K iAodulus of Elasticity (E) 10.152E06 Psi (7,000 kN1an') Shear Modulus (G) 3.916EC6 Psi (2,700 kN1cm2') Dual Rack stainless grounding mid clamp has been tested COm Onellt L1St u. _ .�� and certified to UL 2703. With advanced design, each Material Mid•Clamp o '01 grounding mid clamp pierces through the anodized coatings channel Strut. 01 Lock -Tight M8 Aller Bolt-65mm 01 of the solar module frame to form secure electrical bounds, Luck Washer - 01 which are repeated throughout the array. Dual Rack Grounding Clamp has proven robust in grounding 60-cell and 72-cell Type 1 solar module frames. Comparing with traditional solar module grounding method, Dual Rack integrated:grounding system, including grounding mid clamp and grounding, bounding, splicing three -ill -one stainless lug (GBS-P6, UL467); eliminates separate module grounding hardware, and it creates many parallel grounding paths throughout the array, providing greater safety for system owners, also saves installation time. and hardware cost. ADVANTAGES • Compatible with Dual Rack PV mounting system • Electrically bond. the solar modules together 4 Conforms to UL STD 2703 and Class A Fire Rated En. CLASSIMED % -S Intertek 5000799 :Co fo to UL,SUa 27= EOrdering Specific Package Small Box Big Box Standard Packaging lope 80pc 320pc Weight 1.67.lbs 13.36lbs 53.44lbs Liistallation Guide. � , _ , For detailed instructions please refer to theDual Rack installation guide General Notes RACKING SPECS Drawn By: David D. No. Revision/lasue Date CONTRACTOR r;Ro see.. A*— Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 Lic# 960376 X � Might Solar Michael McMillian 10225 Carmen Rd, Cupertino, CA 95014 ad. April 12, 2016 1h d 10 sod. AS INDICATED nN�d PV SYSTEM 1 ack aW ' A_L _!_L0ELLi..(-t11tn ii -, - PART NO. - DR-BFLK01DUALBACK DR-BFLK-01 5/16'x4"SS Lag Belt FLASH L-KIT 3/8" SS Washer PRODUCT .LINE 4 Heald DON.BaseItem 9 - Product Name i r DR-CFLK-D 1 1jua1Rack:Flash L-kit Clear (12:0 IX 12.0-) Pell . f j - EPDM Washer, i DR-CFLK-02 DualRack Flash L Krt Clear (9 0" x 12 5) DR BFLK-01 DualRack ..Flash L Kit Black 12.0 12 0 i Alurninum'Flashiha, p f3uildl1gq ��DR-FLK2 DualRacklasL Black 25)( H NIATERU1. SPECIFICATIONS #.: Matanal Designation 6005 TS 168 5G Ib1fP 2 7 /cm �. 1. ' V !v r F _ r— _ �. � • .:-�, �' Den. (o) w. _.: ,:. � -�g-� ) F Coefticrent of Thermal expansion (or} 1 308E-051°F(2 35E 05J C) _l l ic Drf_fusiv_rty (1,) ____ _ - 200 00 VJIm K ' - ., d . . - -. _ _ _ t,• U.)%.'r.:� - L,.. a Modulus of Elasticdy (E) • 10 152EOG Ps! (7,000 kNlcgi') _- Shear. Modulus (G) " 3 916E06 Psr 700 kN1an r P - _ — r. j ..-: . �U. ._..y) INSTAL�BTION< GUIDE ECHANICAL L. DUAL RAM,: Tensile -Strength (f ) ,.,. 38 0 Ksi (260 kNlcm,) �..... :, ,a::; ';.i` °`nn'.a _ s` s r*.`,^-. t',, w ,.,�„,-,s•'"...:..s^ - .. _. py . - TensileY�eld Strength (frr) 350 Ksi-(240kN/cam) .. �`•'`-,``~�-'' a.'`• s: �,' ' ',. .;•a; '`� -- ':-a �„i".:: ��,s;,'fa'Si.�,�.tL^7 FLASH L KIT_t :. _-. _ - -< ate; t iR;. E W `'7 4d'"# .f' ".�.. et'' "% --.st ✓ Po.'A4'`.^" C :' F Profile WaII�Tluclmess (t 50 3i inJ10 mtn);.' ...._ ,, g•, Our Dual Rack Flash L-Kit comes in 12.0' x 12.0' and* gq ` CDB�IPOI�ENT LIST4VI�ARRANT�' ` x __. 9.0 x 12.5 sizes and Is designed to be used an MATERIAL 0n 10 Yeer hmrteo warrant}+_,-. _ _, }� - composition/asphalt shingle roofs. Our roof flashing Aummum Fleshing� HsAVv1.,Dtnr � Base o _ slides quickly into place with no need to modify the 3ra x ; 5 s s Hex Boll C 1. 2. 3. 4. - Locate, choose, and mark centers of Gently break seal between shingles Put 5116"x4" lag bolt through L-foot. Secure EPDM washer onto bolt. R 3B ,S S Wa her D rafters to be mounted. Select the and.remove any nails. Slide mount Next slide the EPDM washer up onto Attach bolt and flashing to rooftop. shin le to force a fit. Just a simple, waterti ht seal ever -' _ = 9 p g y 3i8 Flnnce Nut o, _ courses of shingles where mounts up under shingles, with flashing the lag bolt: 5+16'x< b S Ln' Boo 01 will be placed. lined up with rafter center. Mark time. All stainless steel hardware Included for fast, --- - center for dri ling. • EFDMWasher p01- single bolt installation. 10-year limited product warranty:-- .��-:-- •�--,.,: ,,. -N �RDERING:SPECIFICS _.���_ ,�_.�. •- .• � .����,: ��, � ����. �r �� y ProdurS DR-CFLK-01/DR-BFLK�II7 DR�FLK-02,/DR BFLK02 ,k `1"'�.,"�., �.; Net Werght 0 90 Iru i ael 1 151bs l set i - ADVANTAGES i Standard Pack S sat! box S set /.box e; � �'';�� Slenderd Peck Dtmaneion x 14 0' (L).x 13 q' MO x:3:5 a ✓ Fast, simple one bolt Installation = ( ) Standard P¢ck Weig�hl 5 45 bst I box ,r _ fi251bs I box; - .. ; r.s� ✓ Stainless steel hardware (included) 5�. n n - - B,g Pack,_-; 4 small box! brg,pack (20 sell box) _ 4 smell hoz l big pads (20 set! box) 1 Using the rack kit hardware, secure 6. 7 8. All -aluminum 9.0 x 1,2.5 & 12.0 x 12.0� flashing - :. s - 9 You are now ready to attach the Attach the rail to the 1_ foot using Take care not to warp or damage ' Biy Padc Dimelsi 14 0 (L) x 13 0. (W) x 14 0 (H) _ 14 0 (L) x 130 (IRS x 14 0' (H) the racking (1-foot) to the -mount. rack. SI'ideahe 3J8' bolt through 3J8" holf's and hut: the roof panel when tightening the nut. _ _ ✓ 10-year warranty; 25-year expected`llfe FBig Rack We,gM _ . _ . 5 lbs l bmc -- __, _,_ _ . 25.5.6s l baz.� . _ ..._ _. ___ _. _ the rail groove. .Meets or exceeds roofing industry best practices ✓ 100% IBC compliant No Shingle cutting C®�11TACT INFO'� � r DISTRIBUTOR'' INFO (»� Dual Rack:lnc. t ackm .241 N 10th Street, Unit 4 Sacramento CA 95911. info@DualRaCk:net w:WWDualRack et. General Notes ATTACHMENT DATA SHEET Drawn By: David D. No. Revision/leeue Date CONTRACTOR Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 Lic# 960376 f �f Highlight Sear rw}d rr.,. • •ram Michael McMillion 10225 Carmen Rd, Cupertino, CA 95014 ad, April 12, 2016 ®.. sod. AS INDICATED wul.d PV SYSTEM SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION + .'V PERT(NQ 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(cDcupertino.org _ )r'er`y Address 0"Z: CAJZJI7' T n= PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including,basements X X Within each leeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4.and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and Califonnda Residential Codes. The alarms have been tested and are operational, as of the date signed - below. I haves raarl and anraa to rmmnli"lifh tha4arn cl rnnn9finne of thic emfomnnf owne�o�=`(lwnet figent's);Name --- Mi g� ire-M11.0 Si rizdl e.i............... ..............:........................................... nafu€e...a.......... Lrc #.................................... {.Dafe: ............... Smoke and CO form.doc revised 03118114 WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING .DIVISION CUPE6tTiNO 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 buildingft-cupertino.org. L wner ame; m i C.1k L i L3 � t Rio Is your real property a registered historical site? 0 Yeses Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. No Go to Question 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? El Yes Civil Code Sections 1101.1 through 1101.8 do not apply. 0 The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. ,;K-No Go to Question 3. '3� Is water service permanently disconnected for your building? O Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the; form and sign bottom of form. No Go to Question 4. Is your real property built and available for use or occupancy on or before January 1, 1994? 0 No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form; and sign bottom of form. A. Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101;8 apply. Check one of the three following statements and sign bottom of form.. �i1 Please check ONE of the following: My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non -compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). El My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). 0 My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non compliant plumbing fixtures shall be replaced with water conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or unprovements). I, as the owner or owner's agent of this property, certify under penalty of perjury that non -compliant plumbing, fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards. Code, and manufacturer's q indicated in the able onithe rfollowin2 vane. d that the watery-c�onse�plumbing fi .tyres complywith the requirements as m _ Upon completing and signing this Certificate, please return it tolhe $wilding Division in order to final your budding permit. SB407 2015.doe ,revised 08126115