Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
14100107
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 21070 RAINBOW PL CONTRACTOR:FRONTIER SOLAR INC PERMIT NO: 14100107 OWNER'S NAME: SAN JOSE,CA 95123 PHONE NO:(408)927-9335 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL ❑ COMMERCIAL ❑ INSTALL PV SYSTEM ON SFDWL ROOFTOP(25 PANELS) License Class z-(7/. g�(Lic.# 7O C�6 ( / 6.25KW Contractor ry-43 'f-i'o .,i 5'0 t?.( Date 1 0(0_0/ L/ I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the 1iIerformance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$30000 have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:36626030 00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT ; ; 4' - !. WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHI 180 DAYS O' PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAY RO► LAS- CALLED INSPECTI N. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of theAi"v� granting of this permit. Additionally,the applicant understands and will comply Issued by: Date: with all non-point source r-: ations per Cupertino Municipal Code,Section 9 18. / /Q RE-ROOFS: Signature �— ' Date 04/ All roofs shall be inspected prior to any roofing material being installed.If a roof is _./ ; installed without first obtaining an inspection,I agree to remove all new materials for inspection. 0 OWNER-BUILDER DECLARATION Signature of Applicant: Date. I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupe '•• unicip.I Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 05,2. 33,ayf25534. r Section 3700 of the Labor Code,for the performance of the work for which this /O/20 permit is issued. Owner or authorized agent: — Date: /(1/ I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9 18. Signature Date ,4 , _ ALTERNATIVE ENERGY PERMIT APPLICATION I \`U/ 1( wCOMMUNITY / DEVELOPMENT DEPARTMENT•BUILDING DIVISION uvE / ,.,ps\ 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 fr\' CUPIcttTI * (408)777-3228•FAX(408)777-3333•buildinci cupertino.orq PROJECT ADDRESS (9!0,1 D KA 1_ t b O, ` p io - APN# 9))^C ?/ '0--6 o OWNER NAME STREET ADDRESS a\V10 ��1N3 e." ,�� CITY,STATE,ZIP �1`v�` I N....5. ci4C� i FAX CONTACT NAME ��"S 14ODn i, .7 at- (o( D-,J t 7 ESolar`i%�'e.s k-e__4. cc\cRz ' �. F �i.�l 1.r �`( `j STREET ADDRESS CITY,STATE,ZIP F cRO1 vJltoely. LX &,' ') . BS S/W\) 3bS1; 9stZ'3 �t . 2Zy-CS3s— o OWNER 0 OWNER-BUILDER 0 OWNER AGENT CONTRACTOR 0 CONTRACTOR AGENT 0 ARCHITECT 0 ENGINEER 0 DEVELOPER 0 TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS.LIC# 1/n Oto G�N"r t 12- S o c.-YL- . .1%)(---- Cf OotgLlk C.4.0 ,c..4.to �D COMPANY NAME t t �] l � r/--S later. F ^ )s-ZZ14- (b 3 r PHNE STREET ADDRESS 01 W 11� 1'I V / T7W I) CMCJ,.:1 cI�'f���S„A. ss. s i a- 4OV6-ca..-7^`t.33 :ITE T/E�N9ER NAMF. h LICENSE NUMBER I 0 9 2 BUS.LIC# f, f f V COMPANY NAME 94_^ ��1 E-MAIL K M u(WI _ S l FAX N 1�(�O Uegrry. STREET ADDRESS CITY,STATE,ZIP PHO SNEIO-1 o-- a USE OFFD or Duplex 0 Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: 0 Commercial URBAN INTERFACE AREA 0 Yes 4o FLOOD ZONE ❑ Yes 0 No SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION 0 SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: e. 5 #KILOWATTS: 6.3...c TOTAL VALUATION: .50 DESCRIPTION OF WORK 9\45\a i� S ct.c I r (1��;) cyv` _____________2.. rRECEIVEDB.' By my signature below,I certify to each of the f. .wing: am the prop.•'"owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have prod:-.is corre'. I have rea.`.•"Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to.0 .Ing cons. ion. I autho•'tT representatives of Cupertino to enter the above-identifie property for inspection purposes. Signature of Applicant/Agent: , Date: D / ■- ?-8,-- TAL INFORMAT N UIRED — ,- ,.. fl ;ilia OYES, g,COUNTER U '"3 D"STANDARD lD LARGE t ."',s LI 1 AOR PVApp_2012.doc revised 06/20/12 CITY OF CUPERTINO i' +r/, FEE ESTIMATOR— BUILDING DIVISION ADDRESS: 21070 rainbow pl DATE: 10/20/2014 REVIEWED BY: Mendez .•'q1.1-, ` APN: BP#: *VALUATION: $30,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY PENTAMATION SOLAR-RES USE: SFD or Duplex PERMIT TYPE: WORK install pv system on sfdwl rooftop (25 panels) 6.25kw SCOPE 4 yea � ,L lir,ii Port(oec i I I Plumb 1'?crrt Clic(A 1 I IL/0c. ha'l.(1,,,c k 1 1 ,7 .c. pi,rnl). Pt mit Tee;: (nct ,lit crt. his,,- Fi Other Plumb Imp Oil`cr I 1,i.l,as)> Fi ,,,,,,7 ,,,,,,, NOTE:This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn'I info. FEE ITEMS (Fee Resolution 11-053 Eff. 711/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 # Alternative Energy System Suppl.PC Fee: Q Reg. 0 OT 0.0 hrs $0.00 $236.00 1PHOTOVRES Photovoltaic System 4 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:® Reg. 0 OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 (:OOrat;LL I-IOfn lay. 'i,iii i i t"F 4:trai i v: 1"c,'e: 0 Work Without Permit? ® Yes No $0.00 Advanced Planning Fee: $0.00 Select a Non-Residential 0 Building or Structure 0 I,-,i',et Doc trrneniation Fees. 4 Strong Motion Fee: 1BSEISMICR $3.90 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $2.00 tit $5.90 $236.00 TOTAL FEE: $241.90 aT.=tet Revised: 08/20/2014 it • $" B 's rI Mechanical Characteristics llikliiitaligilliffilli, 983min(38714W)X ia45mmi64.76')j1 35mm(13A1(Hl" ani Appr 19.0 kg(419Ib) yi 60s91171arra(aXJprtwtdxltHwala<al4Madoin Ko aM1 .4 '. ' 4mml12AWG) b1<owthpol Izedweath p fconnoolo,o I ,, - F tt7: IEC cefled 641litAO.Lerg701A m(39.41 8r, a IP6°.,urztherp/oo[IEC emfed(ULBsted) - - 4 3bypa tlod to prcv po d by paV hd_ " SD YER TINO- - Y "� Y F ht6nlnll4dtledgli3.2 (0126'6 rhrproaTfw i � i�? Clearoched aluminaalloytype 6063(8144k) Building Department t Electrical Characteristics OCT 2 Ii 2U1 Multi,4frAythle Tvp ( �' , 3l REVIEWED FOR CODE COMPLIANCE q;"6F .1 C "" ....fi , N mal p ( PP) W 1 240 245 250 . Reviewed By : ,...5.,.4..i /rill "'Velieye 6eaWlit+,'mwS°: [ m%;-.-i 64�E, 'a's 1_-r„il �ar ..��,'' '....--.',,..-i..04.,...',.. y cur,..,,„,,..,..,,, A I 7.9 i 8.0 8.1 ¢ �-„ 1:1J990'ij.'iFXk ? .,,,yi::'� ., " "3t ./S„f:seK. ..*t „> tt ,3, ,';8 ,i Short<ircultcurrem list) A 03 8.4 8.6 fworr+ " tri i i;;',.:.i 'ems`\ 1 gift F.,. .. No.ofadls&connections pas 60in swim .:4». `""�,. ,'.:C " a. .,.::W?. r'}. ",..�a=.1.01 spn(4lrsan6>w,�1I fSl «.t�,:: ," ;>:., Module efficiency I 96 i 149 15.2 155 as & •4 `' _� HYUNDAI I GREEN ENERGY T per to coefficient of 9616 -033 1 -032 -032 .. ���y - I 055 039 539.5 a WwW.hhrgleen"coMsolar/en m , 1 3 HEAD OFFICE RIYADH ,a,"� ""f- ` '' ""''"-'' '' `- 1WU,0413891986111111 08(6 D973-Au.Ulsan,f:cla Office 230,29FI.ThePIaz0C.7nter,PO 8008072.f6yad111445,;audl Marta Te8.82.52.2028101-8 Fax:83-524024100 Te1:966-1.I64.4666.5366 Fax'9.41-464.235: SEOUL(SALES&MAP:RING) 00893 9 Y!J11(fl118lj16.'1/fe 2-1111.,Hyundai Bldg-7531.1116ro,J9#999-9u1.641110493.01990 205,BuildIg4,Finaar Sguar•_ShY.hZ9/ed70ad.80E9x232458,08bai.UAE } Tel.d2-0.746.451.7453 Fa,'.82.2.746.7675 191.111.Iwuldalcdal®llld.col.r' Tel:971:44214995 Fa.:'9714425:7996 :1 f - 398019649tlC81. _ 5, ATLANTA ..... .. ......... ......... MOSCOW. .... ......... ...... ... -, 6100060nr 60:11•8.81.61.866s6 GA 30071,05* Worldradeewitw Ent 3.419020 smPr Baia Nab 12.140:40,123610.100•• 1404110 0.11,9t(P10P1/) i W 1 250 255 260 Tel 1478-823.7839 Fax,1478-8234053 Td 7-495--53-1331 F' 7-095-202-1332 �1. x .v. a .T. .... ........... ....... ......... ................. .... ......... ..... .............. ......... I,i'6f,;�..8e "r-�c^', F,<-8S" ,... ..mv,> ,rn, ,Y., LONDON MADRID Curren.phm•(I pp) I A I 83 03 8.4 2'a D.,ihe1largl<5-17Hanvnesmitllf Na,L.}ndon.W60Lci UK Pa:exile ACox1Ahna0lo Flanu02&%6h1alO Speirs @''o"' �""y.�a gg�a. "j` Z 1' $y Z " ' 4 Tel Fax 44.201x741.56'0 Td:3491-732-0454 Fax:34.1-733-2389 a,a b nt O000) 3,nh;'l _.:.e�a` r;a'..,'..t1 c ... 8iD...� ..,v. ..........._ ........_.... .. ..... . ................_...... ..._....... . ShMd rt tOsc),y. A N 87 08 89 Tq(YO • ' -, :' •�a 1:,. -470 8^FLhaa8 cho De ki 849.1.7-I,,,Jra6.368 8 4.u,1dgo.1W-0W6.lapin :.' No.ofc<IIo&connections 1181 1 601084000 Tel:81-3-3211-0742-4 Fax:81-3-3211-2093 �,�" i>,.e:° k: �.R .. . .�4�11l: ._. . . ."ea r..'....? OSAKA ..... ... Module efficiency 96 i 155 159 i ;1161 wN 5er1a3aMAPla.Hd _243Mnm w .160.866040.Osda,5434081,Japan An iRO,A N3)d a$.A,M636(.I�i>I5:• „8, .4..:4 4 'u 44," ."2 "40 %".v 4* Td.814-62614766-7:,..1-6-62614818 Temper to Ffici<ntol0 %M -033 0.33 -033 Tiitpvet484:66411ciblte1l '., %Ili. \ .0b2 .432 _:,\07.742. ®..,...^_.CE®qe \' m.,gin i u �(' "9 £' f. . 41 maean1YaarR4eae_. 000833.11.181rt 9188013 • „�l�p'g$� Y B;OY` 001 t J 3y�y(gC°T1-p!.$.1S/g000 q $U / SMA •.� 0014,`B.7 ro7/�T �/ $A."` $�,f00 L,'$„k .a"8•Y•?R,9T&,`"kl E......"-._._....i CIP.:.�ywm SUNNY BOY 5000RLS]2240,r.—.--.._1 Acces5one5 6.1 i �_ 99 ''''''''._•••-- ' ` /y/.fir ` as I .yW �P.5'e3 dikkro .,��"' r s. ,,�,//,, jn i,r 9a i .� so ' arn4escsust9 x. / 1 v r a ..j swOrrusio s i ' 4' rand, / : �y+� � €- _,.Bu rv.-4eavl „ v-m 'p I c� _.� a9 1; u.4., 44• o.e to . q • l $.: F, I, •s 6 4a d feorore o Opn6naI tem aNiaa9 r r; „s _ OuiwrP«+rl I"'ro ,:oate.mnomnofsa,d'na+s ...:),°,1,'''',7 � <; / - - -Sunny Boy 3000T1.U5 �5unny"Y630' oy 6000TU15 Sunny Bay 7000T4U5'' $ ny 8ay 7700Tam' u@ ,%�;4 f �• ,. J /ii / 208,9 AC •;:240 V AC ' 2OB V AC 240 V AC 208 VAC 240 Y AC '..;.....;0.g V AC• 240 V AC „ ..• , � % 5300 W ,. 6300 W - ,.: 7300 W ^ ft •"A se„ � ,, 4009 6009 4NY 175.4800 210,'-4800 . 245 480 0 270-:480 V •t25V,SQ00 825V• 5009 1250-5009- ' ,1259:5009 ' _ 126V/150�V 12VJ150V k 1259/1509 1251"I1150y '30 A"j 1SA. 30 Al ISA '" � � 30AJ18A 304.(-184 gg / - J2 ,,,q.....,:::,„: '0000 W 5200 W.. 8000 W 6090 W '7000‘A.1 465089 7680 W iAl'•\ _ e -r ar4550 500090 5200 VA 6004'94-„ .'4000 VA 7000 VA -", 6650 VA 768004 I � � � - 208Y1�. 2400(• 208 V/• 2,WYle` 208 V!• 240V1s 2080{�-' R40Yl e'r..,,. .g a1jja�• „� x � 183-2290 217 2W V >183�22FV 211 3640 2290 211 2444 t88 2240 311;26-09' 9 - i .604nI593 40,511 f 4•(,6011/5,9.0 60514 ..18.3;:60.8x,5,,,,40.5(4 �4000/593 48.51iz :G fir• a \ .,r.p/ +a - r/ /j : P C 224 '0 40A4' F'h..: 4ro 29.20' ..0„,v....,:,,,,7‘...,„�£ 03214 • THE WORLD'S ONLY 1/2 • 1/3 J2 42 UR POWERSUP� h a4% : • te a @ c4%' • 4% ar«� • 97% 976% 070 4 974 97-09 r 074% o4/ a?a# ,;i f / c'' -:94.'6% •070% 970%';.• 04046 . 970% • 964% ' 47"n'` '....r-:,�. .;':...- '0444,1,., . •,V ; k�4114 : ..<.;.,;;;,,..„,...›.4;,,,,,,...,„„,„:„.....„.„-;„?.,V , ..:.<, 144, „<'. ,., s ,, .,ter,,., ..a.;:, t n ryygr q' F -P;T .'.4444"4''''M , . r ` •1 .; .\ 4\ e '�� .,, •,,Tri. .-.,..-,:-...,„,,...„:„...,....:................... �e n6 4 L ; '-'"'0 9:m- / Iso( 4' t `,, _.,� enu � qt+e �,vis a '-� a :: !.�,' 387l 7„,_•00l£7 4741 ��. .. '•Glotwl Peak MPP fruddrg ''�- tempi"y f�rrBe a a r '�`ff $.3...%30',5tg ..; . •• �, r .37152, a z1 • �d T - - _ /i�.'„. %`. ,... -..:? ..2.ip4"3•, 404441 101 00x`1,,;;: .1 4 : m.<.Y/.it 4 \ x �7�: �: 144 ,a-at-t,„.1-..t.,,,, . '0 44/ SUNNY BOY 3000TL-US/3800TL-US/4000TL-US/ *a o, .4 N04140.41 - 0 5000TL-US/6000TL-US/7000TL-US/7700TL-US \ �t• . 4/ 40Ar 4 r 4 � a 1/ tZ \x £1= wore •., ;;.m `---,,,,4,4K4 ti kAIM s 0a`f4m" #.@a` 1 rtm111� Tmda ln9 a' :z ' 1'ciilltirC S . Setting new heights in residential inverter performance 4% � 14 41ST �• �V �.� ..a. t1»R OT T¢s.-. .r,,., _ .s....,. The Sunny Boy 3000T1-US/3800TLLS/4000TLLS/5000TL-US/6000TL11S/7000TL-US/7700TL-US represents the next ,4/ g� ,a•�s,V ,; :• 0 441.4 ,; step in performance for ULcerfified inverters.Its transformedess design means high efficiency and reduced weight Maximum i « ..x "," '.• ""?i?- .,<. � '` '18144'€ .444-.�Y 41 "t� 'e' ';`- power producfion is derived from wide input voltage nd operating temperature ranges.Mulfiple MPP trackers and m o/o'„ 3 4.1„0 g, oJo •• rcI y, 1, 7 -talo'. ; a t44 41:40 d 4 e• a,06 . OpkTracr'"Global Peak mitigate the effect of shade and anallow for installation at challenging sites.The unique Secure Power •. ,,,, Ul 17th,U49¢8j,";,36g9b,IkEf,1,S47FCC•PatJ,S,{pau Ab81.CAFf/CSAC232 30Z.i-1 �m"e9 Supply feature provides daytime power in the event of grid outage.High performance,flexible design and innovative x • 4/i `. ,`",�,i s • 'Y. features make the Sunny Boy TL-US series the first choice among solar professionals. "% 4 4' ` 2 + ;C.;=••a'. 58.53000.00412•• ,0014''00811,00.23, ":. .. .: • :88 70(70. 4 I•'°;. t •4.,,,„0� tteeheet a nH.n IRON RIDGE Roof Mount System - XR Rall _ mm XR10 Rail XR100 Rail XR1000 Rail Internal Splices ] n � Alow-rofilemountin rail T ,`x •rs`"" yam. -. �"`s`" �" " p g he ultimate residential A heavyweight mounting All rails use internal splices .;vr" �` + for regions without snow. solar mounting rail. rail for commercial projects. for seamless connections. ' 5s u • 6'spanning capability • 8'spanning capability • 12'spanning capability • Self-tapping screws • ` 7 , , • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails �,. - • Clear anodized finish • Clear&black anod.finish • Clear anodized finish • Grounding Straps offered • Attachments ......... ._.-_..._.._,._.__ ..-.. __..-...._......_...._._ ....,,...... s� '�� FlashFoot Slotted L-Feet Standoffs Tilt Legs 4 i .- Anchor,flash,and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle,up to 45 degrees. • Ships with all hardware High-friction serrated face • Works with vent flashing Attaches directly to rail • IBC&IRC compliant • Heavy-duty profile shape • Ships pre-assembled • Ships with all hardware • Certified with XR Rails • Clear&black anod.finish • Lengths from 3"to 9" • Fixed and adjustable Built for so'ar's toughest roofs. Clamps&Grounding IronRidge builds the strongest roof mounting system in solar.Every component has been tested to the limit and proven in extreme environments. End Clamps Grounding Mid Clamps'a T-Bolt Grounding Lugs Accessories Our rigorous approach has led to unique structural features,such as curved rails and reinforced flashings,and is also why our products are fully certified,code compliant and backed by a 20-year warranty. 44 Wilk Strength Tested 0 PE Certified All components evaluated for superior Pre-stamped engineering letters Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and structural performance. available in most states. modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rolls. • Mill finish&black anod. • Parallel bonding T-bolt • Easy top-slot mounting • Snap-in Wire Clips •Sizes from 1.22"to 2.3" • Reusable up to 10 times • Eliminates pre-drilling • Perfected End Caps Complete Assembly Design Software •Optional Under Clamps • Mill&black stainless • Swivels in any direction • UV-protected polymer End-to-end solution provides 2 Online tool generates a complete bill Free Resources attachment,mounting,and grounding. of materials in minutes. Design Assistant p A.q NABCEP Certified Training 0Integrated Grounding 20 Year Warranty Go from rough layout to fully Earn free continuing education credits, .1 ' engineered system.For free. while learning more about our systems. UL 2703 system eliminates separate 0 Twice the protection offered by Go to BmnRidge.co nfrna *4 Go to Iron Pis ige,comftraining module grounding components. ... competitors. ecli ?3. .:Briefr Installation Overview CEIM AUTHORIZATION TO MARK • Install Roof Attachments •Install appropriate roof flashing and/or standoff for roof type. This authorizes the application of the Certification Mark(s)shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing •Attach L-Feet to flashing or standoff. Report.This authorization also applies to multiple listee model(s)identified on the correlation page of the Listing Report • Prepare Rail ConnectionsThis document is the property of Intertek Testing Services and is not transferable.The certification mark(s)may be (g.0, applied only at the location of the Party Authorized To Apply Mark. •Insert splice into first rail,then secure with Grounding Strap and self-drilling screw. Applicant: IronRidge,Inc. Manufacturer. IronRidge,Inc. •Slide second rail over splice,then secure with opposite end of 1495 Zephyr Ave 1435 Baechtel Road Address: Address: Grounding Strap and self-drilling screw. Hayward,CA 94545 Willits,CA 95490 Country: USA Country: USA Contact: Jon Ash Contact: Jim Norsworthy • Mount&Ground Rails "" Phone: (707)459-9523 Phone: (707)459-9523 FAX (707)459-1833 FAX: (707)459-1833 •Attach rails to L-Feet and level rails. 4;;:; Email: jash._,ironridge.co n Email: jnorsworthvOironridce.corn •Install one Grounding Lug per row of modules. „,,„ '''''''t Party Authorized To Apply Mark: Same as Manufacturer •Connect Grounding Lug to grounding conductor. Report Issuing Office: Lake Forest,CA 600iItali� ' Control Number: 4007559 Authorized by: *�sfl���z for Thomas J.Patterson,Certification Manager Install Modules&Clamps e •Install first module using End Clamps and Grounding Mid Clamps. •Install additional modules using Grounding Mid Clamps. US •Finish row with a second pair of End Clamps. Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. .............................................................................................................................................................................................. TNeNNiabWmmMskbmrtlro axau, uv ofmMmr.C$SISId Is SSdpurwxromeCa tsosq,pamnseekvve,mwmx mmbCISt VtstIs(srssepWalr v,d a IsSn Testing&Certification °qM°mm°'^^ro"^ "”'Q+M' " " ^' +mm�rwro•°m.w^mw.awrm. -emm.ww. ro,.,rra,.mmem^„^,mq,,,m,mrea bwu..aaa s.wcMmnbMato hn.cw.+arumwemoMrtNaoclroaaanm rw carr MawrtrMmmMrn.aer eMrnbxb.p.Uraiswse Cw ewa mrYn ri Module Frame Compatibility ^++°°m.Mme,.,.^.umm..aw..,*.,^m.*..ma�w^mM.r..,,„r..tilt.»am.mM,M.^„»m.m.•..«.aMe«m.+er..w�em ww.,mn,der ,�+ aw a crmwn m wimy W►trot pwua rmr Auuxn.as.ne rete Iq 6wbt n rot tls oMPew a wvq ppoq�Me uage a w crew�m mMa h+ooxe.o wm ms The IronRidge Integrated Grounding iw.M..,ar..m M umwvm.�nm m..�er .aa,nW wm•.e.cw.aa wwwm.me....r.M. System has been tested and certified to — Dimension _ Range UL 2703 by Intertek Group plc. A 31.0mm-51.0mm Intertek Testing Services NA Inc. 545 E. nquin n IL UL 2703 is a proposed UL standard A B 5.08mm(minimum) Telephone 800-3455.3851orr847-4395687Faax84743s7320 for evaluating solar module mounting Any module frames whose parameters are not listed in the and clamping devices.It ensures these prowled table have not been tested for compatibility. Standard(s): UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat-Plate Photovoltaic Modules and Panels,Issue Number 1,October a,2010 devices will maintain strong electrical and — mechanical connections over an extended Product: Standard and Light Rails with Integrated Grounding period of time in extreme outdoor The Grounding Clamp has proven robust in grounding 60-cell and Brand Name: N/A environments. 72-cell solar module frames with box construction and a range of Models: 51.61-GD-005 and 5181-GD-005B anodization thicknesses. , The testing process closely mirrors that I of UL 1703,the solar module testing All ar modules listedrsto UL 1703 and with frame construction within the parameters stated above are compatible with the standard,including temperature and i IronRidge Integrated Grounding System. humidity cycling,electrical and mechanical load testing,and manufacturing quality Go to€ronridge.com/ig reviews. "W ATM for Report 100978592LAX-003 Page 1 of 1 ATM Issued:22tL_ t1�'�" rD te.a15(1JaT13)Mand.tc volt Biie IRONRIDGE XR Rail Family /� Starling Madison Lofquist, Inc. i Zuns ultinb <'t,•ur'.turut and F. (I/CO,e F.rig ineers Solar 6S Not Always 1' r 5224 South 395 Street,Phoenix,Arizona 85040 tel:(602)438-2500 fax:(602)438-2505 www.smleng.com Over their lifetime,solar panels experience countless r extreme weather events.Not just the worst storms in years but the worst storms in 40 years.High winds capable of IronRidge June 16,2014 ripping panels from a roof,and snowfalls weighing *f - 1495 Zephyr Ave Page I of 11 enough to buckle a panel frame. t x s Ilayward,CA 94544 XR Rails are the structural backbone preventing these results.Theyresist uplift,protect + 1 P ' � r Attn:Mr.David F.Taggart,Vice President Products against buckling and safely and efficiently y, transfer loads into the building structure Subject: IronRidge XRIO Rail,Roof Flush Mounting System—Structural Analysis Their superior spanning capability requires fewer roof attachments, reducing the number of roof ( " Dear Sir: penetrations and the amount ,, $ 2 of installation time. We have analyzed the IronRidge XRI O Rail for the subject solar module support system and determined that,for the configurations and criteria described below,it is in compliance with the ,_ applicable sections of the following Reference Documents: Codes:ASCE/SEI 7-10 Min.Design Loads for Buildings&Other Structures International Building Code 2012 Edition California Building Code 2013 Edition s / Other: AC428,Acceptance Criteria for Modular Framing Systems Used to Support PV T x Modules,dated Effective November 1,2012 by ICC-ES Aluminum Design Manual,2010 Edition P i The IronRidge XRI 0 Rail is an extruded aluminum section with an overall depth of 1.75 in.and a net Force-Stabilizing Curve area of 0.363 sq.in. The rails are used to support solar modules,typically,on the roof of a building. Sbped roofs generate both veruceI and lateral See Exhibit A—attached. The rails are clamped to aluminum angle brackets that are either attached forces on mounting rails which can cause themg i to bend and twist.The curved shape of XR Rails directly to the roof framing or attached to a stand that is screwed to the roof framing. The rails are y„ s spedalry designed to Increase stre gth In both mounted across the slo a with a small clearance flush mountin to the under) to roof structure. directions while reslstlng the twisting.This unique P ( g) y g feature ensures greater security during extreme The installed solar modules are at the same slope as the underlying roof structure. jweather and a longer system lifetime. All loads are transferred to the roof framing through the angle brackets by simple bi-axial flexure of i ,� �'" the rails. The maximum span of the rails is governed by either the mid-span flexttral stresses or the I deflection requirement that the rail not come into contact with the roof. The effect of seismic loads(for all design categories A-F)have been determined to be less than the effect due to wind loads in all load conditions and combinations. Therefore,the maximum allowable spans for common load cases are shown in Tables 1,2&3 below for 0-6 degree slopes,Tables 4,5, Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 4 &6 below for 7-27 degree slopes,and Tables 7,8&9 below for 28-45 degree slopes. XR Rails are IronRidge offers All XR Rails are made of marine-grade compatible wah a range of tilt leg aluminum alloy,then protected with en l� FlashFoet and options for flat anodized finish.Anodizing prevents surface �'� other pitched roof �, roof mounting and structural corrosion,while also providing attachments. ,z,..= appllcatlons. amore attractive appearance. a.:; - -- " - » - ' ' '" '°""' Starling Madison Lofquist,Inc. Consulting Structural and Forensic Engineers ' o IronRidge June 16,2014 IronRidge June 16,2014 Mr.David F.Taggart Page 7 of II Mr.David F.Taggart Page 11 of II IronRidge XRI0 Rail,Roof Flush Mounting System--Structural Analysis IronRidge XRIO Rail,Roof Flush Mounting System-Structural Analysis Table 6-MAXIMUM SPANS(inches)-Roof Slope 7 to 27 Degrees-Wind Zone 3 Notes-Tabulated values arc based on the following criteria: Wind Ground Snow Load I. Building mean roof height 30 ft Rail Rail Speed 10 20 30 40 50 60 70 80 90 2. Risk Category! Exposure mph 0 psf psf psf psf psf psf psf psf psf psf 3. Solar module long dimension=67.5 in 100 59 59 55 49 43 39 35 33 31 29 4. Provide 2 in.clear between roof and rail 105 56 56 55 49 43 39 35 33 31 29 5. End cantilever span(max)=0.40 x maximum span front above tables 110 54 54 54 49 43 39 35 33 31 29 6. No rail splices in end spans 120 49 49 49 49 43 39 35 33 31 29 7. No rail splices in middle 1/3 of interior spans category 130 46 46 46 46 43 39 35 33 31 ' 29 8. Single simple span(s). Spans listedin the tables'above may be multiplied by 1.08 for 140 42 42 42 42 42 39 35 33 31 29 continuous rails of 3 or mare spans. 150 40 40 40 40 40 39 35 33 31 29 160 37 37 37 37 37 37 35 33 31 29 170 35 35 35 35 35 35 35 33 31 29 Our analysis assumes that the rails,including the connections andassociated hardware,are installed 100 50 50 50 49 43 39 35 33 31 29 Ina workmanlike manner in accordance with.the"IronRidge Roof Mount Installation Manual"by 105 48 48 48 48 43 39 35 33 31 29 IronRidge and generally acceptedstandards of construction practice.Additional information is 110 45 45 45 45 43 39 35 33 31 29 available at the IronRidge web site,lronRidge.com. Verification of PV Module capacity to support 120 42 42 42 42 42 39 35 33 31 29 the.loads associated with thegivenarray shall be the responsibility of the Contractor or Owner and CateCgory 130 39 39 39 39 39 39 35 33 31 29 not IronRidge or Starling Madison Lofquist. 140 36 36 36 36 36 36 35 33 31 29 150 33 33 33 33 33 33 33 33 31 29 160 31 31 31 31 31 31 31 31 31 29 The adequacy of the supporting roof framingis to be determined by others. 170 29 29 29 29 29 29 29 29 29 29 100 46 46 46 46 43 39 35 33 31 29 105 44 44 44 44 43 39 35 33 31 29 110 42 42 42 42 42 39 35 33 31 29 Please feel free to contact me at your convenience if you have any questions. 120 38 38 38 38 38 38 35 33 31 29 Category 130 35 35 35 35 35 35 35 33 31 29 """ D Respectfully yours, 0s �`e 140 33 33 33 33 33 33 33 33 31 29 .01r/. 1)t. ri 150 31 31 31 31 31 31 31 31 31 29 °,�', -..°tir'+'f►'t 160 29 29 29 29 29 29 29 29 29 29 170 27 27 27 27 27 27 27 27 27 27 - Tres Warner,RE. Notes-see page 11 Design Division Manager Starling Madison Lofquist,Inc. Consulting Structural and Forensic Engineers Staling Madison Lofquist,Inc. Consulting Structural and Forensic Engineers 7_ .g- Subflashing Waterproofing Method:Three-Course QBase Universal Tile Mount I QMUTM Installation Tools Required:gloves,hammer,brush,roofing nails,roofing cement,trowel,roll of reinforcing fabric,sealantcompatible Additional Dimensions with roofing material , , / 1. r THIS EDGE TOWARDS ROOF RIDGE ti'' 5 i� Post 01.25 A,,/'•A. ( 1 •0� 2.50 11so ` � � ,.. '�- r ,- % I 18.00 04.00 ' 4X 0.32THRU(CLEARANCE O FOR 5/16 HARDWARE) Gather materials needed. Clean away dust and debris around QBase. Apply a bead of sealant in the shape of ah upside dam U on the backside of the subfashing 9.00 Tr ` � / ,f r; 18.00 7.00 r � /, THIS EDGE TOWARDS ROOF RIDGE >,f r r 1.44 1 TOP FLASHING(REM S) 9a� .�!IIi,._ I.50 t r _ (" .n•`= '` ,.a, 3.45iiii41111 .50 Install esubflashing over the post making sure Fasten the zubflas gi ace with two roofing � e f 4.50 QBASE(ITEM 2)AND POST(ITEM 7) r ofing Apply d of h erofro shIng menta 1"the g,00 I'Mount alt t the edge closest to the cone is on the downhill nails,one m each top cornet top and sides of the wbfasking with at least l"ex lCIL MOtNTf f Y side. tending past the sides of the flashing onto tel felt I Layer should beabo ttheth ck ess ofan ckel 1 -TITLE: t.Bt QMUTM:QBASE UNIVERSAL TILE ' ' y .02� �� MOUNT / "� �� %r/s rh .. Youpre now ready to proceed wrth your QBASE SUB FLASHING(ITEM 4) uxlsssomem�mream SizE DRAWN Br. RADS REV. S,r./ '`' - top file flashing installation(steps 7-Son page 2) .._. .. ....... .. ........q Map xrnuueorAw iN«a�a .A^DAIe.....10/1/2D13 b Digital Installation instructions are also -- --A5G1E1s^ xrsss -I cIsioa �u zorz 5 ..... A 3. ...2. 1 „ avoilabie at our website. r www quit km ou ntpv tom/support/ downloads html ' - Par more mformatmn on rile roofing best -: " d r ;'"c: Tract cos and code compliance visrt rhe g= � y e � � %j ;7 The Roof Institute's webshe: ti www.tileroofing.org While cement is still wet apply 3 pieces of rein- After first layer of cement Is dry apply second layer forcing fabric strips where felt paper and Flashing over reinforcing fabric to finish waterproofing of meet-a 14"strip along the top,and.a 10"strip subflashing. along each side. Quick Mount 1` 925-478-8269•www.quickmountpv.com•info@quickmountpv.com El 7.2.3-4 Oct-2013,Rev6 617.234 2700 Mitchell Dr.,Bldg 2•Walnut Creek,CA 94598 Oct-2013,Rev 6 02013 by Quick Mount PV.All rights reserved. Sofa 4 oro locus Product Datasheet DIAGRAM-TYPICAL.CONFIGURATION ENERGY 31111111 ....... Shielded CATS ., INTERNET LGate 120 RESIDENTIAL SOLAR MONITORING SOLUTION ;? .-; MIEli ELECTRICAL MINE SERVICE :r � - - � v,' '' ,• INVERTERS) LGATE 120 ., .rala PV ARRAY • . _ : DIMENSIONS SOCKET METER LOCUS ENERGY METER BASE COMM MODULE METER MODULE The LGate 120 combines a revenue-grade.solid-state power meter with an advanced communications gateway. v 6.es in These components work in conjunction to remotely monitor the performance of residential solar energy installation , ;te regardless of panel or inverter type.The LGate 120 is a one-piece completely under glass meter which installs 63t n , easily using a standard socket base Performance data is uploaded in near real-time to the Locus Energy SolarOS r ,-. monitoring platform which provides a suite of tools and analytics for asset managers. ._ "7 5.46in 6.00 8) DATA COLLECTION - - --7.30 in -----• AC energy data is collected by the meter and passed to the communications module.Additional system — --- — - ------- ----- -- ----- - ---- -------- performance data can be collected directly from meteorological sensors and supported inverters via RS-48 5 or Zigbee connections.All data is stored in non-volatile memory and then automatically uploaded to SolarCS at user configurable intervals. SPECIFICATIONS IIIMEMEM11.1111111111.111111.1111.11111 E=11=111111111.111111111111111111111.11111 Prstessbr .ARMS embedded CPU Accuracy ANSI 1220 class 52% NETWORK CONNECTIVITY Os cost m verslonofDn x2.6,OTAermwereupdates Voltasel.wrts PD•080vAC The communications gateway inside the LGate,120 supports plug and play connectivity through a cellular or Ethernet Memory 128,MDRAM Phoses.' Stour 000ase,5510500 eatSOoreOou network connection.Price the unit is installed and powered on,it will immediately begin transmitting data without 000105 LCD sheen 500000 Type 2s any configuration.For maximum reliability,the communications gateway will automatically route uploads between the I/o COmPLIAG CE wireless and wired connections if either of the networks are unavailable. Rs4e5 z was and 4.wile -ANSI 12.20 class 51% Modbus FCC Part 158 7igbee,. PTCRU.. FEATURES AT&T Carnet Compliance CT IM UMIC AT,ONS • ANSI 012.20 power meter • Low cost installation LAN Ro451n/100 Ethernet,hal 00011 00Cr 0,0000 Potartty PHYSICAL • RS-485 and Zigbee inputs • Doesn't require entrance into the house Cellular 3G GSM Enc omrire SIENA 3R Tyne GSM cellNelworiu,O UNCPor stator Weight 8cz • ua or Ethernet connectivity • Plug arid O:ay activation • ,ver the al firmware updates • Configurable data upload interval n:1or, s.ssR s 5 7t [v rorment 2U t0 700 9�k 1.ti no nCensmg I Warranty 5 yna'limited werrente'. i �� ® Without Bypass Single Meter Sockets Without Bypass 100 Amp Seif-Contained 100 Amp Self-Contained _..._p... ._w.......... ,. D •-__....1N ...._... • Single meter position ° w- ___—_7 y ,4, • Designed to receive watthour meters that meet ANSI C12.10 a • Surface or semi-flush mounting ° • /;� 1 1 '. • Overhead or underground feed HA l _ [ (1 xA t.Git �4 4... • ... >5 dr I} i na:*; 0 6) 0 0 �s Type 3R construction (I) � • Snap type sealing ring included • 5th jaw provision at nine o'clock-011 series only s • Ring style //� ,;� _ 0 0 ( �r„L�+U• AZ o Az o l;") C�� J • UL 414 listedcomplies with ANSI C12.7 i...... —__. b sun ® AZ o. CT �eO co i* O �f ' • ANSI 61 gray acrylic electrocoat finish Fig. 1 AB Fig.2 AB m p 17 Fig.3 AB iD u : • 5th jaw kit se catalog#50365 o` 4 • Screw type sealing ring—catalog#25016D(included with MS73 .Vii. >_ -. ..t- catalog numbers) • Steel and clear lexan covers for socket opening 1 AW hubs 0.UG10R Lw Rvnn DIu a5lA.(iu I py. o * 5 5 j0 14AWe-2/OAWe I4AWe-2f0 AWG F•.i 12 8 448 O• (J -a ;n v a '+ t 150 125 600 30416 7 AW 14 AWG-1A1 AWG 14 AWe-2/O MG rig 3 17 8 4`51 ,......_. .......................................................................................................................................................................................................................... O O Arc- Arc Cotacroa LW RANGE DRENSRWs OtiCwsj � soo; � vim� '- " " -r .r..._ © FIg.5 ��aa Fig.—AB 6 r--=I ConaJCxoucrcw LLC RANGE DIAt01M861316..-...-...-_.......... o .._....__...._........._.___........_.._._..._...._...__.___......._....__...s S(IKlt3)J © 800 `®0�®' ®� i ,__ ___._____...___...__.._.__..__........___..._______.___..___._................._.______. .„An1 t...Metersochals shown on/Ms page have certain short circlet current ratings when used ill condormance with Pie tables on page 8. I hnOoke AB1Y _ AZ=Y-115`-lw-r I HA=NM HUB FIg.7 2 COOgRB-Line Data subject to change without notice.Consult local utility for area acceptance.All dimensions in inches. Data subject to change without notice.Consult local utility for area acceptance.All dimensions in inches B-Line 3 a + h w Locus ENERGY October 22nz,2013 This letter is to certify that the LGate 120 and LGate 320 are communication boards built into the Vision • • Meter 25 CL200 and 16S CL320 socket meters,respectively. Each of these meters was certified to the ANSI C12.20(class 0.2%)standard by Underwriters Laboratory on June 7,2013 as part of the Vision Meter Family(Project Number 12CA71134,Job Number 1001541515,and Report Number R12CA71134- ANSI). ANSI C12.20 is currently recognized as the industry standard for electrical socket meters in both utility and PV monitoring applications.These tests cover both meter accuracy as well as several safety standards including electrical and environmental safety,as well as resistance to various types of mechanical shock.As electrical socket meters are generally installed and maintained by trained and certified professionals,rather than consumers,they do not fit the typical criteria for additional types of UL or IEC certification. If you have any further questions regarding the product certification of any Locus Energy LGate-branded device,please contact us at support@locusenergy.com. The locus Energy Team Locus Energy,LLC www.locusenergy.com 1 I 2 I 3 I 4 I 5 �l ,, PHOTOVOLTAIC SYSTEM RAINBOW DR SHEET INDEX -- -- - - - - - - PV0.0 COVER AND SITE PLAN . - PV1.0 GENERAL NOTES SYSTEM SIZE: GATE PV2.0 ARRAY LAYOUT(1) AC/DC kW STC: 5.356kW\6.25kW I i CONDUIT RUN ON PV2.1 ARRAY LAYOUT(2) �I p,_ I EXTERIOR WALL PV3.0LINE DIAGRAM EQUIPMENT: MAIN . .-� ® I PV4.0 LABELS A PV MODULES: (25)Hyundai HIS-M250MG(BK) Cr 1 _ J INVERTER(S): (1)SMA SUNNY BOY 6000TL-US-22 a I I KEY: I 1 I ---- PROPERTY LINE u 0 I I SUBPANEL — — ® — CONDUIT RUN 0 DC DISCONNECT SCOPE OF WORK: m 1 I I L 1 DRIVEWAY DRIVEWAY Ac AC DISCONNECT WAY INSTALLATION OF A SAFE AND CODE-COMPLIANT I I I SOLAR MODULE El®JUNCTION BOX GRID-TIED SOLAR PV SYSTEM ON AN EXISTING i MAIN SERVICE PANEL MONITORING UNIT El COMBINER BOX RESIDENTIAL ROOF TOP. ® PV METERETER ROOF OBSTRUCTION CONDUIT RUN ON ROOF — — CONDUIT RUN ON ROOF im INVERTER NOTE: 0 APPLICABLE CODES: KEEP ARRAY 36"FROM RIDGE AND PROVIDE REQUIRED PATHWAY(S)FROM •EAVE TO RIDGE IN ACCORDANCE WITH 2013 CALIFORNIA FIRE CODE / CONDUIT RUN 2013 CBC(BASED ON 2011 NEC) \ o ON ROOF 2013 CBC PLOT PLANS ` — b 2013 CRC CUECKED BY \ i 2013 CPCMC APN: 36626030 N 2013 CM '� 0 �i �. ¢ & i 2013 CFC DATE \ LOCAL AMENDMENTS TO CA CODES I j �'' � r I CONTRACTOR INFORMATION: PLA Ni°TG i �'� ` i I B \ _ _ _ _ _ a I FRONTIER SOLAR SAN JOSE DATE 5807 WINFIELD BOULEVARD \ — I SAN JOSE,CA 95123 g1,DG. f3EP-71C. --` \ I JURISDICTIONAL INFORMATION: �� — ► '` " CUPERTINO, CITY OF ; L"— rcTfNo 10300 TORRE AVENUE \ , . �3uildin ..� 9 Depar�ertCUPERTINO; CA 95014 i OCT 2 0 2014 NOTES TO INSTALLER: oF \ +IEWDARRAY TO BOS(DC):CONDUIT RUN FROM ARRAYS,ROOF FOR CODE COMP MOUNTED, AND ON EXTERIOR WALL TO BOS. E cOpy \ LIANCE BOS TO POC(AC):CONDUIT RUN FROM BOS ON EXTERIOR G� i•_, {.,.. I Reviewed By _� / WALL TO(E)MSP: Y 1 \ I ADDITIONAL NOTES:CONDUIT SHALL BE ETCHED AND PAINTED r TO MATCH EXISTING ROOF COLOR . �`�, �,�'�'�'i `� �i�I it O POC:LINESIDE BREAKER IN(E)MSP . APPROVED 1 I This set of plans and specifications MUST be kept at the 1 job site during construction. ft is unlawful to make any 1 FOR INSTALLER USE ONLY changes or at+nr,+,,, ,,, POST INSTALL SUNEYES REQUIRED? NO 1 I I CERTIFY THAT NO CHANGES HAVE C \ BEEN MADE TO THE ARRAY LAYOUT: / , CUSTOMER INFORMATION: 0 `y I RAMESH RAO 21070 RAINBOW PLACE i� ` I I CUPERTINO CA 95014 r'ERAIIIT NO. /7117/ SITE PLAN I I (408)973-1652/#1330693 N SCALE : N.T.S. I I - SU1 n 1GEVIT I�/" DESIGNED BY: REV#: GENERATE POSITIVE -- -- SN 0 PV- 0.0 1 2 3 4 5 GENERAL NOTES: ELECTRICAL NOTES: GENERAL NOTES: El.ALL EQUIPMENT IS LISTED FOR USE. Ni. DRAWINGS ARE DIAGRAMMATIC ONLY.THE LOCATION AND ROUTING OF E2. MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC. RACEWAYS SHALL BE DETERMINED BY THE CONTRACTOR UNLESS OTHERWISE •E3.ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION SHALL BE • NOTED OR STANDARDIZED. NEW AND LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY. N2.ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS. E4.AN INVERTER IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY N3. IF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT,WIRE, EQUIPMENT DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND A DEVICES,OVERCURRENT PROTECTION,GROUNDING SYSTEMS, ETC. (ALL DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN EQUIPMENT AND MATERIALS)THE CONTRACTOR SHALL BE RESPONSIBLE FOR IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK PROVIDING AND INSTALLING ALL MATERIALS AND SERVICES REQUIRED BY THE VOLTAGE HAS BEEN RESTORED. STRICTEST CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO E5.ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION. ENSURE COMPLETE COMPLIANCE WITH ALL CODES AND TO ENSURE THE E6.ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT LONGEVITY AND SAFETY OF THE OPERABLE SYSTEM. CALCULATED AT THAT COMPONENT. N4.ALL OUTDOOR EQUIPMENT SHALL BE MIN. NEMA 3R RATED. E7.ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL BE N5. METAL CONDUIT AND ENCLOSURES SHALL BE USED WHERE PV SOURCE OR PROPERLY GROUNDED. _ OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING. E8. DC EQUIPMENT SHALL BE 600VDC RATED MINIMUM. N6. MODULES SHALL NOT BE PLACED OVER ANY PLUMBING VENTS AND AT LEAST 6"ABOVE FLUSH VENTS. E9. MARKINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE DISCONNECT EQUIPMENT MIGHT BE ENERGIZED. N7.THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL E10.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES REQUIREMENTS GIVEN BY UTILITY COMPANIES. OR JUNCTION BOXES/COMBINER BOXES PER APPROPRIATE JURISDICTIONAL N8. FOR ADDITIONAL EQUIPMENT SPECIFICATIONS,SEE PROVIDED CUT SHEETS. REQUIREMENTS. N9.ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO E11. FOR ANY UNGROUNDED PV SYSTEM,A LABEL READING: REQUIREMENTS BY NEC AND THE LOCAL AHJ.THE AHJ MAY HAVE SPECIAL LABEL B REQUIREMENTS BEYOND THE SCOPE OF THIS DOCUMENT. THIS MAY ENCOMPASS "WARNING-ELECTRICAL SHOCK HAZARD.THE DC CONDUCTORS OF THIS PHOTOVOLTAIC LANGUAGE INCLUDING, BUT NOT LIMITED TO,THAT FOUND IN NEC ARTICLES SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED." 690.5(C),690.14(C)(2),690.17,690.53,690.35(F), 690.54,690.64(6)(7)and SHALL BE PLACED AT EACH JUNCTION BOX,COMBINER BOX, DISCONNECT AND DEVICE 705.10 WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE. N10. INSTALLER TO FOLLOW ALL LOCAL JURISDICTION GUIDELINES. E12. INVERTER(S)SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION N11.ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC DEVICE. REFERENCES. E13.ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. , CUPERTINO / STRUCTURAL NOTES: E14.THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CEC/NEC. i' Quilling Department Si. MOUNTS ARE DIAGRAMMATIC AND EXACT LOCATION MAY CHANGE, BUT E15.BACKFED SOLAR BREAKER(S)SHALL BE INSTALLED AT THE OPPOSITE END OF THE i SHALL BE ACCURATELY SPACED. CIRCUIT OR FURTHEST AWAY FROM THE MAIN BREAKER. ,* .^ OCT 2 0 2014 S2. MOUNTS SHALL BE STAGGERED WHEN NECESSARY TO EVENLY DISTRIBUTE E16.ALL WIRE,VOLTAGES,AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO REVIEWED FOR CODE COMPLIANCE LOAD AMONGST RAFTERS. TEMPERATURE DERATING AND LOCATION. Reviewed By .6/47-‘-,t/ S3. DO NOT SPLICE RAILS IN MIDDLE 50%OF SPAN BETWEEN TWO MOUNTS. E17.ONLY COPPER(CU)CONDUCTORS SHALL BE USED. CONDUCTORS SHALL BE STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. C E18. DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED E19.ALL MODULES AND RACKING SHALL BE GROUNDED VIA IRON RIDGE RAIL INTEGRATED CUSTOMER INFORMATION: GROUNDING (PLEASE SEE DATA SHEET)OR WITH TIN PLATED DIRECT BURIAL RATED LAY IN RAMESH RAO LUGS USING STAINLESS STEEL HARDWARE,STAR WASHERS,AND THREAD FORMING BOLTS 21070 RAINBOW PLACE OR WEEBS. CUPERTINO, CA 95014 E20.ALL EQUIPMENT SHALL BE GROUNDED, INCLUDING BONDING JUMPERS WHERE (408)973-1652/#1330693 NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF RAIL.. S U I n I G E V I T I�/® DESIGNED BY: I REV#: GENERATE POSITIVE SN 0 PV- 1.0 1 I 2 I 3 I 4 I 5 MODULE SPECIFICATIONS (25)Hyundai HIS-M250MG(BK) NOTE: KEEP ARRAY 36"FROM RIDGE AND PROVIDE REQUIRED PATHWAY(S)FROM MODULE WEIGHT: 41.9 EAVE TO RIDGE IN ACCORDANCE WITH 2013 CALIFORNIA FIRE CODE MODULE LENGTH: 64.76 MODULE WIDTH: 38.7 ROOF 1 SPECS 3' 32'-7" 14'-5" ,� RAFTER SIZE: 2X12 NOMINAL RAFTER SPAN: 8'- 11" A e') 1111 I I ARRAY 1 I I ROOF 1 I I I I II 1 I RAFTER SPACING: 24" I I I I I I 1 1 I I 1 1 I I I I I I I i I I I I I I I 1 1 I i I I ROOF MATERIAL: CONCRETE FLAT TILE W/O BATTEN 3 --0-----r---*----I-----I---t---t--1-10---i----r---t----r---$-- -� 0 I ARRAY 1 SPECS -� I i j I _1 1 I - NUMBER OF MODULES: 11 <° --010-----1----4----1--—1---tlk -—1----I-— ---1---4------ -4--- I TOT. MOD.WEIGHT(lbs): 460.9 f f f f f f f f - f -- i'OI --- I RACKING WEIGHT(lbs): 104.8 �' 2' ARRAY WEIGHT(lbs): 565.7 — 10 1 I I I .•'? i I I I 1 1 1 1 I i I 1 I I ARRAY AREA(sqft): 191.4 (V .'I•— i I I i I I I i 1 ' ' I ' ' ' ' ' ' ARRAY DEAD LOAD(lbs/sgft): 3 0 A RRAY-1 LAYOUT NUMBER OF MOUNTS: 24 LOAD PER MOUNT(Ibs): 23.6 SCALE: 3/16"= 11-0" ARRAY AZIMUTH (°): 90 ARRAY TILT(°): 18 NUMBER OF FLOORS: 2 B Solar Module 0111111!, �, 1 l d N SYMBOL K E Y: MOUNT RAILIronRidge XR1 ———— RAFTERS 4 // — ° ROOF— SETBACK iliffil '. CUPERTINO 1� ,Ai = L e BuildingDepartment SOLAR MODULE a 0 0 STRING CONFIG .�V. QMUTM Universal Tile 71(-- 2' --All 8'-11" ;,1,4 t : 2 0 2014 ® SKYLIGHT ® CHIMNEY Concrete Flat Tile w/o Battens A RRAY-1 SECTION REVIEWED FOR CODE COMPLIANCE 0 PLUMBING OR 0 / ATTIC VENT 3" x 5/16"-Lag1111°71a 1 1 111111W SCALE : 3/8"= 1'-0" Reviewed By: 5 � 177 p ATTIC VENT C 2x12 Nominal,24 O.C. CUSTOMER INFORMATION: 11.1 MOUNTING DETAIL RAMESH RAO SCALE 21070 RAINBOW PLACE CUPERTINO, CA 95014 C` , (408)973-1652/#1330693 S U 1 n 1 G E V I T iv® DESIGNED BY: I REV#: GENERATE POSITIVE PV_2.0 SN 0 1 I 2 I 3 I 4 I 5 I I I I I I I I i I 1 i I I I I i I I I Ii I I I I I . —1' 2' If— ' • 0 • • . • • • t I I I I I I in I I I I I I 1‘ -4- I I I 4-0-4- --4- - --4----I ---4-- .:', --op- , ROOF 2 i I ARRAY 2 A I 1I I I I I rI I 6? i ± - -1 4t-1- -- I---®----r-4-c-54- bo 0 1 I T 1 r I 1 1 1 - ---1---1-4-- -1- I--(k&1 1 1 1 1 1 I I I 10-r---t I 0 - t_ i If I I I I I I i I I I I I I I I I I ii I I I I I I I I I I I I I I I I I I I NO FLY ZONE b 714— 3' 4 35'-11" 4. 391-7" JI' 0 i RRAY-2 LAYOUT SCALE : 3/16"= 1,-0" MODULE SPECIFICATIONS NOTE: B KEEP ARRAY 36"FROM RIDGE AND PROVIDE REQUIRED PATHWAY(S)FROM (25)Hyundai HIS-M250MG(BK) EAVE TO RIDGE IN ACCORDANCE WITH 2013 CALIFORNIA FIRE CODE MODULE WEIGHT: 41.9 MODULE LENGTH: 64.76 MODULE WIDTH: 38.7 SYMBOL KEY: - ROOF 2 SPECS ® MOUNT --- ---------1 — RAFTER SIZE: 2X12 NOMINAL ------- RAIL it RAFTER SPAN:5 14'- ,-- CUPERTINO 8" — ——— RAFTERS — 4 1 -I' 1_ RAFTER_.,..., --.1 - ROOF SPACING: 24y,---::': ,, Building Departnent SETBACK ROOF MATERIAL: CONCRETE FLAT TION/O BATITEN 3 !ill" 40 .---"*---- „-•,.. ..... (3°. ---- ARRAY 2 SPECS TT 2 p 2014 CI NUMBER OF MODULES: SOLAR MODULE kL-VitIVVEC) +-:OR CODE COWL P 584N/f ew ed By .3,-.9."" ,47 1 PLUMBING OR cee :TRING CONFIG. KYLIGHT TOT. MOD.WEIGHT(lbs): CHIMNEY .--- 0 --- ARRAY YINWG EWIGEHIGTH(Tib(slb; 40.9 El '3): ATTIC VENT ATTIC VENT C 698 11 ARRAY AREA(sqft): 243.7 CUSTOMER INFORMATION: 71t--- ARRAY DEAD LOAD(lbs/sqft): 2.8 RAMESH RAO 2' --Ai 14'-8" / 21070 RAINBOW PLACE NUMBER OF MOUNTS: 22 CUPERTINO, CA 95014 0 i RRAY-2 SECTION LOAD PER MOUNT(Ibs): 31 (408)973-1652/#1330693 SCALE : 3/8"= 1'-0" ARRAY AZIMUTH (°): 90 SUilGEVITY ARRAY TILT(°): 18 DESIGNED BY: REV#: GENERATE POSITIVE PV-2.1 NUMBER OF FLOORS: 1 SN 0 1 I 2 I 3 I 4 I 5 ELECTRICAL KEY: MODULE ELECTRICAL SPECIFICATIONS -t-1- BREAKER (25)Hyundai HIS-M250MG(BK) - - SWITCH NOTE: El SCREW TERMINAL SINGLE#8 GROUNDING CONDUCTOR USED FOR DC SHORT CIRCUIT CURRENT(Isc): 8,6 • FUSE GEC&AC EGC PER ARTICLE 690.47 • SPLICE OPEN CIRCUIT VOLTAGE(Voc): 38,2 w EARTH GROUND OPERATING CURRENT(IMP): 8,1 /T1 CHASSIS GROUND • - —- GEC OPERATING VOLTAGE(VMP): 30.9 EGC MAX SERIES FUSE RATING: 15 STC RATING: 250 A PTC RATING: 222 TO (E)SUB PANEL DESIGN CONDITIONS HIGHEST 2% DB DESIGN TEMP(°C): 29 #10 PV-Wire MIN. MEAN EXTREME ANNUAL DB(°C): 0 (4) (4)#10 THWN-2 (3)#8 THWN-2 (1)#10 EGC (1)#10 EGCA (3)#8 THWN-2 FREE AIR 1/2" EMT (1)#8 GEC (1)#8 GEC INVERTER 1 SPECIFICATIONS 3/4" EMT 3/4" EMT SMA SUNNY BOY 6000TL-US-22 (E) 200A Challenger MSP W/ RATED WATTS(EACH): 6000 — 120/240V 2P 3-W 1cp AC OPERATING VOLTAGE(V): 240 AC OPERATING CURRENT(A): 25 (N)Sunny Boy 6000TL-US-22 1 INVERTER W/ INTEGRATED 125A 2P NUMBER OF MPPT CHANNELS 2METER c---- ____. INVERTER EFFICIENCY: 0.965 DC DISCONNECTS MPPT 1 INTEGRATED DC DISCONNECT 0 1 STRING OF (-LOCUS 35A 2P AC METER INVERTER 1 MPPT 1 SPECIFICATIONS 11 MODULES DC OUTPUT m m GEC _°�' _ MAXPOWER POINT CURRENT(Imp): 8.1 B MAX POWER POINT VOLTAGE(Vmp): 339.9 O MPPT 2 1 STRING OF + ' e.' "••- 14 � L ______ MAX SYSTEM VOLTAGE(Voc): 454.3 14 MODULES INVERTER m m SOURCE CIRCUIT CURRENT(Isc): 10.8 MAX SHORT CIRCUIT CURRENT(Isc): 10.8 i INVERTER 1 MPPT 2-SPECIFICATIONS V MAXPOWER POINT CURRENT(Imp): 8.1 MAX POWER POINT VOLTAGE(Vmp): 432.6 - MIN. NEMA3R UL LISTED JUNCTION BOX WITH 90°C TERMINAL RATINGS GEC IRREVERSIBLY SPLICED TO MAX SYSTEM VOLTAGE(Voc): 578.2 LOCATED ON ROOF EXISTING GEC OR BONDED DIRECTLY SOURCE CIRCUIT CURRENT(Isc): 10.8 TO EXISTING GROUNDING ELECTRODE MAXRCUI,,' RCUIT CUR6641 1 I INC, 10.8 � ,' f duiIJing Dp£;,rtrneri ate' - OCT '20 2014 REVIEWED EOR CODE COMPLIANCE C MAX Voc= 14 x-25°C x(38.2 x-0.0032/°C)+534.8VDC=578.2VDC CONDITIONS OF USE= 10.75N0.76/0.8= 17.68A 25 MODULES TOTAL ,' Imax=8.6A x 1 STRINGS x 1.25= 13.4375A BASIC AMPACITY CALC= 16.8 25 x 222(PTC WATTS)x 0.965=5356 CEC WATTS "6.1 EWINFO�TION] CONDUCTOR SIZE FOR 17.68ADC=#10 AWG INSTALLATION SHALL USE MIN.#10 AWG Sunny Boy 6000TL-US-22 MAX OUTPUT CURRENT=25A RAMESH RAO MAX DESIGN CURRENT=25A x 1.25=35A 21070 RAINBOW PLACE CUPERTINO, CA 95014 CONDUIT ELEVATION: 1/2 TO 3-1/2"=22°C (408)973-1652/#1330693 HIGH AMBIENT TEMPERATURE:29°C EXTREME LOW: 0°C S U f 1 G E V I T Y® ROOFTOP AMBIENT TEMP: 51°C=0.76 DESIGNED BY: I REV#: GENERATE POSITIVE CONDUIT FILL:0.8 PV-3.0 SN 0 ___ 1 2 I 3 I 4 I 5 NEC 690.5(c) NEC 690.31 (E)3&4; 2012 IFC 605.11.1 INTERACTIVE PHOTOVOLTAIC POWER SOURCE PLACE THIS LABEL ON INVERTER(S)OR NEAR PLACE ON ALL JUNCTION BOXES, EXPOSED GROUND-FAULT INDICATOR(ON INVERTER(S) U.O.N.) RACEWAYS EVERY 10'AND 1' FROM BENDS RATED AC OUTPUT CURRENT(A): 25 AND PENETRATIONS, ADJACENT TO THE NOMINAL OPERATING AC VOLTAGE(V): 240 MAIN SERVICE DISCONNECT INVERTER.1 MPPT 1 DC DISCONNECT • WARNING PHOTOVOLTAIC SYSTEM DISCONNECT RATED MAX POWER POINT CURRENT(Imp): 8.1 ELECTRIC SHOCK HAZARD RATED MAX POWER POINT VOLTAGE(Vmp): 339,9 A IF A GROUND FAULT IS INDICATED, PHOTOVOLTAIC POWER NORMALLY GROUNDED CONDUCTORS r MAX SYSTEM VOLTAGE(Voc): 454.3 MAY BE UNGROUNDED AND ENERGIZED SOURCE SHORT CIRCUIT CURRENT(Isc): 10.8 NEC 690.17(E) NEC 690.35(F) INVERTER 1 MPPT 2 DC DISCONNECT PLACE THIS LABEL ON ALL DISCONNECTING PLACE THIS LABEL AT EACH JUNCTION BOX, COMBINER BOX, MEANS WHERE ENERGIZED IN AN OPEN POSITION DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED PHOTOVOLTAIC SYSTEM DISCONNECT CIRCUITS MAY BE EXPOSED DURING SERVICE: RATED MAX POWER POINT CURRENT(Imp): 8.1 RATED MAX POWER POINT VOLTAGE(Vmp): 432.6 — MAX SYSTEM VOLTAGE (Voc): 578.2 ELECTRIC SHOCK HAZARD SHORT CIRCUIT CURRENT(Isc): 10.8 DO NOT TOUCH TERMINALS ELECTRIC SHOCK HAZARD TERMINALS ON BOTH THE LINE-AND LOAD THE DC CONDUCTORS OF THIS SIDE MAY BE ENERGIZED IN THE OPEN PHOTOVOLTAIC SYSTEM ARE UNGROUNDED POSITION AND MAY BE ENERGIZED NEC 705.12(D)(2)(b) PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT(I.E. MAIN PANEL(AND B SUBPANEL IF APPLICABLE)) INVERTER OUTPUT CONNECTION DO NOT RELOCATETHIS OVERCURRENT DEVICE NEC 705.12(D)(3) PLACE LABEL ON ALL EQUIPMENT CONTAINING CUPERTINO — OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER ( - TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE � - t�uiirJing Department SOURCES. AM,.,.::: OCT2 0 2014 A CAUTION i tFVlEVVED 1-:OR CODE COMPLIANCE eviewed By _'5 s,.• :7.¢r CONTAINS MULTIPLE POWER c SOURCES CUSTOMER INFORMATION: iiil RAMESH RAO 21070 RAINBOW PLACE CUPERTINO, CA 95014 (408)973-1652/#1330693 S U f1G E V I T Y® DESIGNED BY: I REV#: GENERATE POSITIVE' PV-4.0 SN 0 Address 1 SMOKE I CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPUANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION IM TOE AVENUE • CUPERTINO, CA 9W 14-3M -3255 (408) 777- 3228 • FAX (406) 777-3333 • buik9ma ertins� „-s PURPOSE FIVE iris affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314.2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required.. GENERAL INFORMATION Existing single family and multi #amity dwellings shall be provided with Smoke Ala. and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existin dw $1000.00, CRC Section R3I4 and CBC Sections 9072.11.6 and 428.6 re g � units exceeds Monoxide .Alarms be installed in the following locations: q that Smoke Alarms and/or Carbon Outside of each aivavtuCM ..CO ALARM separatie sl area in tip immediate vicmiiy of tip X x bedrooms On mery level of a dwelEn unitiaclu basements X Within eachsleemrw,,,,,, X Carbon Monoxide alarms are not required in dwellings which do not contain fuel burning appliances and that do not have an attached garage. Carbon monoxide aiarmms con3bined with smoke CBC Section 420.6 and shall be approved the shall comply with pPr by Office of the State Dire Ism. Power Supply: In dwelling units with no commercW power Supply, alarm(s) may be so bathe operated. In existing dwelling units, dam's are permitted to be sokl baste p ` battery do not result in the removal of wall and y � �� where �� or alterations do ceiling finishes or there is no access by means of atticy base meztt or crawl space. Refer to CRC Section 8314 and CBC Sections. 9072.11.4 and 420.62. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above - referenced property, I hereby certify that the alami(s) referenced above haslhave been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational as of the date signed below. mo doc revised 03118114